Reliable!
The Most Compact,
Attractive and Easily
Installed Sprinkler
Ever Designed.
Features
1. 11/{Total adjustment provided by
adjustable inlet versions.
2. ½" Total adjustment provided by
economical standard inlet version.
3. Adjustable inlet version available with
either 1" NPT male or female threads
eliminating costly reducing coupling.
4. Small diameter escutcheon.
5. Available in brass, chromeorwhitefinish.
6. Multiple orifice sizes for design flexibility.
7. Listed by Underwriters Laboratories
Inc. & Underwriters' Laboratories of
Canada. Approved by Factory Mutual
Research Corp. & Loss Prevention
Council, NYC BS&A No. 587-75-SA.
Today's modern buildings demand that a sprinkler not
only provide the best fire protection but also achieve an
attractive appearance. Reliable's Model G Recessed
Sprinkl_er meets both crite(ia. It combines the fire fighting
capability of a proven sprinkler with the smallest practi-
cable recessing unit. Its small profile does not disrupt the
overhead aesthetics, and yet one vertical glance upward
gives a visual assurance of the finest in fire protection,
an automatic sprinkler system.
ASo4002:~-
•
·""
Model G
Recessed
Automatic
Sprinkler
. . .
,.,;
':""4.W.," .. ~ ·-
Bulletin 111 M
The Mo_del G Recesse_d Sprinkl_er's threaded two-piece
construction makes InitIal field installation a very easy
task. It allows ceilings panels to be removed without
shutting down the fire protection thus facilitating mainte-
nance of above ceiling services. The adjustable one inch
NPT inlet versions have one and one half inches of
adjustment which eliminates both the normally required
reducing couplin_g and the need to accurately cut drop
nipples. This sprinkler ca~ be adjusted a_fter the ceiling
Is. In_ place and. even while the system Is pressurized
ellm1nat1ng the final corrections to pipe hangers or ceil-
ings that might otherwise be required.
The Reliable Model G Automatic Sprinkler is the heart
of the Recessed Sprinkler. This sprinkler utilizes the
center strut solder in compression principle of construc-
tion. The fusible alloy, captured in the cylinder of a small
solder capsule by a stainless steel ball, acts as the trigger
of the sprinkler. When the fusible alloy melts, the sprin-
klers operating parts spring free from the sprinkler clear-
ing the waterway and allowing the deflector to distribute
the discharging water.
DJ
C
iD cc,-_
:,
The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York10552
Sprinkler Maximum Ceiling
Classification Rating Temperature
Of oc Of oc
Ordinary 135 57 100 38
Ordinary 165 74 100 38
Intermediate 212 100 150 66
Total
Sprinkler Inlet Adjustment • Nominal Orifice
Non-Adjustable ½' ½" (15mm)
Non-Adjustable ½' 7/rn' (1)
Non-Adjustable 1/2" 3/s' (11
Non-Adjustable 1/2' 17/32" lll
Adjustable 11/2' ½'
Adjustable 11/2'' 1116• (1)
Adjustable 1½" 3/a" '"
Adjustable 1'/t 15mm
Standard Finishes*
Sprinkler Escutcheon
Bronze Brass
Bronze White Painted
Chrome Bright Chrome Bright
Chrome Bright Chrome Satin
Chrome Bright White Painted
Bright Brass Plated (l) Bright Brass Plated
Black Plated Black Plated
White Painted (2J Polyester Coated
Polyester Coated (2)
*~pec1al Ftnishes upon request.
(1 Only frame, deflector and cap are plated.
(2) Only frame and deflector are painted or coated, operating parts
are chrome plated. UL Listed and MEA Approved only.
K Factor Approval
U.S. Metric Thread Organizations
5.62 81.0 ½"NPT(R½) 1,2,3.4,5
4.24 61.0 1/2''NPT(R1/2) 1,3.4
2.82 40.6 ½'NPT(R1/2) 1,3,4
7.96 114.7 ½' NPT (R1/2) 1,3
5.53 79.7 1' NPT Male or Female 1,2,3,4
4.24 61.0 1" NPT Male or Female 1,3,4
2.75 39.2 1" NPT Male or Female 1,3,4
5.53 79.7 R1 Male or Female 5
*Sprinkler escutcheon provides½" of the total adjustment. Adjustable inlets, when used, provide 1" of the total adjustment.
(1) Identified by pintle extending above the deflector
NPT Threads per ANSI B2.1
R1 Threads per ISO 7/1-1982 (BS 21: 1973)
Ordering Information
Specify
1. Temperature Rating
2. Nominal Orifice
3. Sprinkler Finish
4. Escutcheon Finish
5. Sprinkler Type: Either
Non-Adjustable Inlet (Fig.1)
1" Male Adjustable Inlet (Fig.2)
1" Female Adjustable Inlet (Fig.3) ~-------------.,
CCII.WC
~1.
1/;" cscurcHtON ('Ji ,wusn.,c,,r
/Jf/,/0/S/ON, i,i PARV/T>ICSIS 11, M/1.IW(rcr,s
Approval Organizations
1.Underwriters Laboratories Inc.
2. Factory Mutual Research Corp.
• Light Hazard Occupancies-No Limitations
• Ordinary Hazard Occupancies-Groups 1 &2, Wet Systems Only
3. Underwriters Laboratories of Canada
4. NYC BS & A No. 587-75-SA
5. Loss Prevention Council
• XLH, OHI and OHII Occupancies Only
6. NYC MEA 258-93-E
Note: Unless otherwise indicated, ordinary hazard approvals are
without limitations. 7/16" & 3/8" orifice sprinklers are limited to light
hazard occupancies.
,..,.~,-, I C<><.!Pt.ll<G RCDUCff•
J J,•· ;J/f" /JI/OP mPPU ro cc1t11<C /)/.,(NS,0,,
::rp,,;:: -j ,.:uwc
-r,•,.~,~,.7/;
\_L,J_/ '-'~'~' -~ •• ~" .. '.&
:,/11·
½" NPT Non-Adjustable Inlet
Figure 1
1" NPT Male-Adjustable Inlet
Figure 2
1" NPT Female-Adjustable Inlet
Figure 3
2.
Product Description and Installation
The Reliable Model G Recessed Sprinkler has been
designed with ease of installation in mind. A choice of
three inlets with up to one inch adjustment coupled with
the Yi' escutcheon adjustment enables most system to
be installed using pre-cut drop nipples. The adjustment
can be accomplished after the ceiling installation and
while the system is pressurized thereby providing sprin-
kler protection before construction is completed.
The Non-Adjustable inlet version (Figure 1) consists of
the Reliable Model G Sprinkler with an attached cup
recessed in the ceiling. A ceiling hole of 2 ¼" diameter
is recommended.
The Adjustable inlet version uses the same sprinkler as
the Non-Adjustable inlet type except that 1" of additional
adjustment is provided by a telescoping sprinkler inlet
section that threads in or out of a stationary Coupling
Reducer ( either 1" male or 1" female) as shown in figures
2 or 3. The Sprinkler-Cup assembly comes attached to
the inlet Coupling Reducer and is retained from separa-
tion past its maximum adjustment length by a snap ring.
This combination is simply installed after the system drop
nipple, elbow or tee has been "roughed in" to the
dimensions shown in figures 2 or 3. Wrenching means
are provided by hex flats on the coupling reducer as
depicted in the figures--do not wrench on any other part
of the sprinkler. After the ceiling tiles have been cut and
installed in place (a 2¼" diameter hole is recommended),
the sprinkler can be adjusted using the RC-1 Concealed
Wrench.
Figure 4
3.
When using the wrench in this application, however, do
not over-torque beyond the adjustment stops.
Figure 4 shows a ½ " NPT non-adjustable inlet sprin-
kler, with the attached sprinkler cup combination in-
serted into the special Reliable Model RC-1 Installation
Wrench. This wrench must be used. The wrenching pads
of the sprinkler easily slip into the rectangular cut-outs of
the wrench as the outside diameter locates the threaded
cup. A½" drive ratchet can then be used for installation
and tightening.
Figure 5 shows the removal of the wrench. Care should
be taken during this procedure to avoid hitting the de-
flector with the wrench. The wrench should be lowered
until it clears the threaded cup, and then moved horizon-
tally to clear the sprinkler. The installation is completed
by threading the escutcheon. on until it contacts the
ceiling. To avoid leaving smudge marks on the ceiling,
the Reliable Model FEA Flush Sprinkler Escutcheon
Wrench should be used. See Bulletin 205 for details.
Note:
1. Use hex wrench flats on Coupling Reducer to tighten
Adjustable Sprinkler into fittings. Do not use RC-1
Wrench for this purpose.
2. Do not install the Model G Recessed Sprinkler in
ceilings which have positive pressure in the space
above.
Figure 5
)
)
Product Description
The Reliable Model G Automatic Sprinkler utilizes the
center strut solder in compression principle of
construction. The fusible alloy is captured in the
cylinder of the solder capsule by a stainless steel ball.
When the fusible alloy melts, the ball moves into the
cylinder allowing the cylinder to fall away from the
sprinkler. When this happens, the lever is released to
spring free from the sprinkler so that all of the operating
parts clear from the waterway allowing the deflector to
distribute the discharging water.
Except for the parts in the cylinder as mentioned
above, the sprinkler components are made from
copper based alloys for maximum corrosion
protection. Lead plated, wax coated or wax over lead
plated sprinklers are available for specially severe
environments. Chrome plated sprinklers are available
for decorative purposes.
All sprinklers are individually hydrostatically tested.
All sprinklers are identified as to their fusing point by
markings that appear on several of the operating parts
and by an identifying color that appears on the frame.
Sprinkler Types
Standard Upright -This deflector configuration is
normally used with exposed piping installations. Water
is distributed laterally and downward in a wide pattern
approximating a hemisphere which is completely and
uniformly filled with water in the form of small drops or
spray. At a sprinkler height of 10 feet (3m), a circular
area of approximately 20 feet (6.1 m) in diameter is
covered by the water discharged at the minimum
pressure.
Standard Pendent -This deflector configuration is
normally used where the space above the piping is not
adequate or where a concealed piping installation is
employed. The discharge characteristics of the
standard pendent are virtually identical to the
standard upright as described above.
Large and Small Orifice -By varying the orifice
size, a large or small orifice sprinkler is created that
will distribute as much as40% more water or 65% less
water than the normal ½" (15mm) orifice sprinkler.
These sprinklers are identified by the orifice size that
is stamped in the base of the sprinkler and by the
pintle that extends from the deflector-the exceJ;.tion is
the large orifice sprinkler with the¾" NPT (R ¼) inlet
thread where the size of the inlet is sufficient to
classify this sprinkler as one having a larger than
standard orifice.
Bulletin 11 0Q
Model G
Automatic Sprinklers
Spray Upright,
Spray Pendent
And Conventional
Pendent
Small Orifice Upright
(With Pintle Screw)
Conventional
Conventional -This deflector configuration is used pri-
marily in those countries where the LPC installation rules
have precedence. The sprin kier is designedtodistribute
a portion of its water discharge upward against the ceil-
ing with the balance downward. It may be installed in ei-
ther the upright or the pendent position. Sprinklers with
conventional deflectors are available with orifice sizes
correspond·1ng to light, ordinary and extra-high hazard
installations.
Application and Installation
Standard sprinklers are used in fixed fire protection system;:
Wet, Dry, De luge or Preaction. Care must be exercised that the
orificesizes,temperatureratings,deflectorstylesandsprinkler
spacings are in accordance with the latest published stan-
dardsofthe National FireProtectionAs soci ation orthe ap prov-
ing authority having jurisdiction.
The sprinklers must be installed with the Reliable Model D
Sprinkler Wrench. Any other type of wrench may damage the
sprinkler.
The approvals or listings of Reliable Automatic Sprinklers by
major approving organizations are shown in the tabulated list
provided on the back of this bulletin.
*Patent No. 4,440,234
The ReliableAutomaficSprink\erCo., Inc., 525 North MacQuesten Park way, Mount Vernon, New York 10552
0
0
Technical Data
~K" Factor Sprinkler Identification
Sprinkler Number (SIN)
Sprinkler Type us Metric Height Approvals ssu SSP
Standard-Upright (SSU) and Pendent (SSP)
Deflectors Marked to Indicate Position
½' (15 mm) Standard Orffice with ½' NPT (R½) Thread 5.62 81.0 2¼" (73 mm) 1, 2, 3, 4, 5, 6, 7 R1025 R1015
7,,(t ( 11 mm) Small Orifice(1) with ½" NPT (R½) Thread 4.24 61.0 3;Y,,• (81 mm) 1,3,7 R1023 R1013
¾" (10 mm) Small OrificeI1I with½' NPT (R½) Thread 2.82 40.6 3;Y,s" (81 mm) 1,2,3, 7 R1021 R1011
Y,{ (8 mm) Small OriliceI1I with½" NPT (RY,) Thread 1.98 28.5 3r,, (81 mm) 1, 3,7 R1022 R1012
1½{ (20 mm) Large OrificE!1) with½" NPT (R½) Thread 7.96 114.7 3r,, (81 mm) 1, 2,3,7 Rt026 R1016
%," (20 mm) Large Orifice with ¾" NPT (R¾)Thread 8.20 118.2 21)(, (75 mm) 1, 2,3, 7 R1027 R1017
20 mm XHH with 20 mm Thread 8.20 118.2 75.4 mm 4,5,6 R1027 Rt017
10 mm XLH with 10 mm Thread 4.10 59.1 73mm 4, 5, 6 R1024 R1014
Conventional-Installed in Upright or Pendent Position
10mm XLH with 10mm Thread 4.10 59.1 73mm 5 R1074
15mm Standard Orifice with (RY.2) Thread 5.62 81.0 73mm 4,5,6 R1075
20mm XHH with (RY,) Thread 8.20 118.2 75.4 mm 4,5 R1077
m Identified by pintle extending above deflector. Sprtnkler height includes pintle extension.
Temoerature Ratinas Maintenance
Maximum
Sprinkler Ambient
Rating Temperature Frame (1)
Classification 'F ·c 'F ·c Color
Ordinary 135 57 100 38 Black
Ordinary 165 74 100 38 Uncolored
Intermediate 212 100 150 66 White
High 286 141 225 107 Blue
(1) Frame color does not apply to pmnted or plated sprinklers-Use
sprinkler rating as identified on operating parts.
Model G Sprinklers should be inspected quarterly and the
sprinkler system maintained in accordance with NFPA 25. Do
not clean sprinklers with soapandwa ter, am mo nia or any other
cleaning fluids, Remove any sprinkler that has been painted
(other than factory applied) or dam aged in anyway.A stock of
spare sprinklers should be maintained to allow quick replace-
ment of damaged or operated sprinklers. Prior to installation,
sprinklers should be maintained in the original cartons and
packaging untl used to minimize the potential for damage to
sprinklers that would cause improper operation or
non-operation. Use only the Model D Sprinkler Wrench for
sprin kier removal and in stal la tion. Any other type of wrench may
damage the sprinkler,
Finishes l1l
Standard Finishes
Bronze -All Temperature Ratings
Chro:11& -All Temperature Ratings
White -All Temperature Ratings
Onlv Frame and Deflector are Painted
Sneclal A'"' ... lication Finishes
Bright Brass Plated -Only frame, deflector and cap are plated. 135'F (57°C), 165'F
(74'C), 212'F (100'C) Temp. Rating.
Black Plated -Only frame, deflector and cap are plated. All Temp. Ratings.
Polyester Coated (2) -Only frame and deflector are coated.
Lead Plated -165°F (74'C), 212'F (100'C) and 286°F (141'C) Temp. Ratings.
Wax-Coated (3) -165'F (74°C) Clear Wax, 212°F (100'C) Brown Wax.
Wax-Coated Over
Lead Plated (3) -165°F (74.,C) Clear Wax, 212°F (100°C) Brown Wax.
(1) Other colors and finishes are available. Consult factory for details.
(2) UL listed and NYC MEA Approved only.
131 212'F (IOO'C) brown wax maybe used on 286'F (141'C)
sprinklers when maximum ambient temperatures do not exceed 150°F
(66'C). UL Listed, FM Approved, NYC MEA 258-93-E.
Approval Organizations
1. Underwriters Laboratories, Inc.
2. Factory Mutual Research Coq:ioration 3. Underwriters' Laborator',es of Canada
4. Loss Prevention Council
5. Pleniere Assemblee
6. Verband der Schadenversicherer eV
7. N.Y.C. BS&A No. 587-75-SA
N.Y.C. MEA 258-93-E
Ordering Information
Specify
1. Model G 2. Deflector
• Upright
• Pendent
• Conventional
3. Nominal Orifice 4. lnletThread
5. Temperature Rating
6. Finish
The equ'1pment presented in this bulletin is to be Installed In accordance with the latest pertinent Standards of the Nat!Onal Fire Protection Association, Factory Mutual
Research Corporation, or other similar organizations and also with the provisions of governmental codes OI' ordinances whenever appl!cable.
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qual'lf'1ed and
reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by
'ftglla
The Reliable Automatic Sprinkler Co., Inc.
(800)431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 668-3470 Corporate Offices
www.rejiablesprink'9r.com Internet Address
Revis"ion lines ind·1cate updated or new data.
EG. Pnnted r1 U.SA 12IOO PIN 999997CXX5
A~ofoo2-1
Reliable! Model G4
Concealed
Automatic
Sprinkler
Bulletin 121 G
OJ
C
~ :,
The Concealer®
A Concealed Sprinkler
With ½" or 1 ½" Adjustment
Features
1 . ½" Total adjustment provided by economical
standard inlet version.
2. 1 ½" Total adjustment provided by adjustable
inlet versions.
3. Adjustable inlet version available with either
1" NPT male or female threads eliminating
costly reducing coupling.
4. Simple sturdy cover attachment.
5. Smooth aesthetic ceiling profile.
6. As heat sensitive as an exposed sprinkler.
7. Available in white or other color painted or
brass, chrome, or black plated finishes.
8. Ordinary and intermediate temperature
ratings.
9. Multiple orifices for design flexibility.
10. Threaded cover does not require clips or
springs.
11. Listed by Underwriters Laboratories Inc. and
Underwriters' Laboratories of Canada.
NY.C. BS&A No. 587-75-SA.
12. U.S. Patent No. 4,880,063.
Application
. .
. --'"' _-0
·-,. ·•'"'"
The Reliable Model G4
Concealer is the most versatile
concealed sprinkler available.
It provides the best form of fire
protection while offering an at-
tractive appearance and ½
inch of cover adjustment for
ease of installation. The ad-'--------~
justable 1" NPT inlet versions have one and _one half
inches of total adjustment and they also elIm1nate the
need for a reducing coupling. The small diameter cover
plate is easily and positively attached and blends into the
ceiling, concealing the most dependable fire protection
available, an automatic sprinkler system.
The Concealer® is designed for use where aesthetic
appearance is important. Offices, hospitals, motels and
restaurants are but a few of the applications where It can
be used. It is available in different orifice sizes allowing
G)
the designer to optimize system performance, thereby
achieving a most efficient installation.
The Concealer® can eliminate the need for precise
cutting of drop nipples. The threaded cover plate as-
sembly can be adjusted without tools so it mates accu-
rately with the ceiling. The fire protection system need
not be shut down to adjust or remove the cover plate as-
sembly.
Product Description
The Reliable Model G4 Concealer uses the proven
Model G fusible element in a standard style sprinkler
frame with a drop-down deflector. This assembly is re-
cessed into the ceiling and concealed by a flat cover
plate. The cover plate and sprinkler cup assemblies are
attached using a strong threaded engagement. This
threaded engagement provides ½" of cover adjust-
ment. The cover plate is attached to the skirt using an or-
dinary temperature classification solder. This results in a
strong cover plate assembly with an ordinary tempera-
ture rating, and an intermediate temperature sprinkler
which can be installed in 150°F environments. When the
temperature at the ceiling rises, the solder holding the
cover plate fuses, allowing the release of this part and
thus exposing the sprinkler inside to the rising ambient
temperature.
The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552
•
The subsequent fusing of the sprinkler element opens the
waterway and causes the deflector to drop into position to
distribute the discharging water. Any secure engagement of
the threads between the cover plate and cup will assure that
the drop-down deflector is properly located below the ceil-
ing when a sprinkler operates.
Installation
Do not install The Concealer® in ceilings which have
positive pressure in the space above.
After a 2% inch diameter hole is cut in the ceiling, the
sprinkler is to be installed with the Model G4 Wrench. The
wrench has drive tangs which insert into cup slots. When
installing a sprinkler the wrench is first positioned into the
sprinkler/cup assembly until the wrench tangs engage
drive slots in the top of the cup (there are two sets of mat-
ing drive slots in the cup). The sprinkler is then tightened
into the pipe fitting. When inserting or removing the
Standard Temperatures
Classification Sprinkler Cover Plate Max. Ceiling
Temp.
Ordinary 135°F/57°C 135'F/57'C 100°F/38'C
Ordinary 165'F/74'C 135'F/57'C 100'F/38'C
Ordinary 165'F/74'C 165'F/74'C 100'F/38'C
Intermediate 212'F/100'C 165'F/74'C 150'F/66'C
Installation Data
wrench from the sprinkler/cup assembly care should
be taken to prevent damage to the sprinkler. DO NOT
WRENCH ON ANY OTHER PART OF THE SPRIN-
KLER/CUP ASSEMBLY.
The adjustable inlet versions are similar to the stan-
dard Model G4 except that an additional 1" of adjust-
ment is provided by means of a telescoping inlet
section that threads in or out of a stationary coupling
reducer (either 1" male or 1" female) as shown in Fig-
ures 2 or 3. These sprinklers must be installed before
the ceiling is in place, by wrenching on only the cou-
pling reducer hex flats. After the ceiling has been in-
stalled with holes for the sprinkler, each telescoping
inlet section is to be adjusted with the G4 Wrench. Fi-
nal adjustment of each cover is made by hand turning
the cover in the clockwise direction until it is tight
against the ceiling.
Ordering Information
1. Sprinkler Model
2. Temperature Rating
3. Nominal Orifice
4. Cover Plate Finish
5. Inlet Type
Note: Unless otherwise
specified, the 165"F
sprinkler will be provided
with the 165°F cover.
Approval Organizations
1. Underwriters Laboratories, Inc.
2. NYC. BS&A No. 587-75-SA
3. Underwriters' Laboratories of
Canada
Total Nominal Sprinkler Inlet Adjustment Orifice
"K" Factor Thread Approvals
Note: Approvals are light and
ordinary hazard, except for small
orifice sprinklers which are limited
to light hazard occupancies. The
cup and skirt are fabricated from
plated steel and are intended for
interior non corrosive applications. us
Non-Adjustable ½" ½"' (15mm) 5.62
Non--Adjustable ½" ¾6'' 4.24 ,
Non-Adjustable ½" ¾1' 2.82
Adjustable 1½" ½'" 5.53
Adjustable 1½" ¼ff' 4.24
Adjustable 1½" %" 2.72
Metric
81.0 )~" NPT 1,2,3
61.0 ,½" NPT 1,2,3
40.6 It NPT 1,2,3
79.7 1" NPT Male or Female 1,2,3
61.0 1" NPT Male or Female 1,2,3
39.2 i" NPT Male or Female 1,2,3
Installation Wrench
Model G4 Sprinkler Wrench
Cover Plate Finishes
• Bronze
• Bright Brass Plated
• Chrome Plated
• Black Plated
• White
Other colors and finishes
are available, consult
factory for details
Note: Paint or any other
coatings applied over the
factory finish will void all
approvals and warranties.
)-,;" NPT Non-Adjustable Inlet
Figure 1
1" NPT Male-Adjustable Inlet
Figure 2
1" NPT Female-Adjustable Inlet
Figure 3
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standar?s of the National Fire Pr?tection Association, Factory Mutual Research
Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 70 years, and are installed and serviced by the most highly qualified and
reputable sprinkler contractors located throughout the United States, Canada and foreign countries
Manufactured by The Reliable Automatic Sprinkler Co., Inc.
Reliabl~ (800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 668-3470 Corporate Offices
www.reliablesprinkler.com Internet Address
II\_ Recycled ~ Peper
Revision lines indicate updated or new data
E.G. Printed in U.S.A. 4/99 PIN 9999970014