Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 120; AS040027; Permit1/22125, 10:05 AM Job Address: Permit Type: Parcel No: Lot#: Reference No.: PC#: Project Title: Applicant: AS040027 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS040027 2525 EL CAMINO Status: ISSUED REAL SPRINK Applied 2/25/2004 1563020900 Approved: 3/16/2004 0 Issued: 3/16/2004 Inspector: AEROPOSTALE, SUITE 120 OH AS PLAN CHECK & INSPECTIONS Owner: BRADSHAW ENGINEERING CORP PLAZA CAMINO REAL about:blank 8645 ARGENT ST SANTEE CA 619-448-4300 Fees($) 100 Add'I Fees ($) 0 C/O WESTFIELD CORP INC 11601 WILSHIRE BLVD LOS ANGELES CA Total($) 100 Balance($) 0 1/1 Reliable! The Most Compact, Attractive and Easily Installed Sprinkler Ever Designed. Features 1. 11/{Total adjustment provided by adjustable inlet versions. 2. ½" Total adjustment provided by economical standard inlet version. 3. Adjustable inlet version available with either 1" NPT male or female threads eliminating costly reducing coupling. 4. Small diameter escutcheon. 5. Available in brass, chromeorwhitefinish. 6. Multiple orifice sizes for design flexibility. 7. Listed by Underwriters Laboratories Inc. & Underwriters' Laboratories of Canada. Approved by Factory Mutual Research Corp. & Loss Prevention Council, NYC BS&A No. 587-75-SA. Today's modern buildings demand that a sprinkler not only provide the best fire protection but also achieve an attractive appearance. Reliable's Model G Recessed Sprinkl_er meets both crite(ia. It combines the fire fighting capability of a proven sprinkler with the smallest practi- cable recessing unit. Its small profile does not disrupt the overhead aesthetics, and yet one vertical glance upward gives a visual assurance of the finest in fire protection, an automatic sprinkler system. ASo4002:~- • ·"" Model G Recessed Automatic Sprinkler . . . ,.,; ':""4.W.," .. ~ ·- Bulletin 111 M The Mo_del G Recesse_d Sprinkl_er's threaded two-piece construction makes InitIal field installation a very easy task. It allows ceilings panels to be removed without shutting down the fire protection thus facilitating mainte- nance of above ceiling services. The adjustable one inch NPT inlet versions have one and one half inches of adjustment which eliminates both the normally required reducing couplin_g and the need to accurately cut drop nipples. This sprinkler ca~ be adjusted a_fter the ceiling Is. In_ place and. even while the system Is pressurized ellm1nat1ng the final corrections to pipe hangers or ceil- ings that might otherwise be required. The Reliable Model G Automatic Sprinkler is the heart of the Recessed Sprinkler. This sprinkler utilizes the center strut solder in compression principle of construc- tion. The fusible alloy, captured in the cylinder of a small solder capsule by a stainless steel ball, acts as the trigger of the sprinkler. When the fusible alloy melts, the sprin- klers operating parts spring free from the sprinkler clear- ing the waterway and allowing the deflector to distribute the discharging water. DJ C iD cc,-_ :, The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York10552 Sprinkler Maximum Ceiling Classification Rating Temperature Of oc Of oc Ordinary 135 57 100 38 Ordinary 165 74 100 38 Intermediate 212 100 150 66 Total Sprinkler Inlet Adjustment • Nominal Orifice Non-Adjustable ½' ½" (15mm) Non-Adjustable ½' 7/rn' (1) Non-Adjustable 1/2" 3/s' (11 Non-Adjustable 1/2' 17/32" lll Adjustable 11/2' ½' Adjustable 11/2'' 1116• (1) Adjustable 1½" 3/a" '" Adjustable 1'/t 15mm Standard Finishes* Sprinkler Escutcheon Bronze Brass Bronze White Painted Chrome Bright Chrome Bright Chrome Bright Chrome Satin Chrome Bright White Painted Bright Brass Plated (l) Bright Brass Plated Black Plated Black Plated White Painted (2J Polyester Coated Polyester Coated (2) *~pec1al Ftnishes upon request. (1 Only frame, deflector and cap are plated. (2) Only frame and deflector are painted or coated, operating parts are chrome plated. UL Listed and MEA Approved only. K Factor Approval U.S. Metric Thread Organizations 5.62 81.0 ½"NPT(R½) 1,2,3.4,5 4.24 61.0 1/2''NPT(R1/2) 1,3.4 2.82 40.6 ½'NPT(R1/2) 1,3,4 7.96 114.7 ½' NPT (R1/2) 1,3 5.53 79.7 1' NPT Male or Female 1,2,3,4 4.24 61.0 1" NPT Male or Female 1,3,4 2.75 39.2 1" NPT Male or Female 1,3,4 5.53 79.7 R1 Male or Female 5 *Sprinkler escutcheon provides½" of the total adjustment. Adjustable inlets, when used, provide 1" of the total adjustment. (1) Identified by pintle extending above the deflector NPT Threads per ANSI B2.1 R1 Threads per ISO 7/1-1982 (BS 21: 1973) Ordering Information Specify 1. Temperature Rating 2. Nominal Orifice 3. Sprinkler Finish 4. Escutcheon Finish 5. Sprinkler Type: Either Non-Adjustable Inlet (Fig.1) 1" Male Adjustable Inlet (Fig.2) 1" Female Adjustable Inlet (Fig.3) ~-------------., CCII.WC ~1. 1/;" cscurcHtON ('Ji ,wusn.,c,,r /Jf/,/0/S/ON, i,i PARV/T>ICSIS 11, M/1.IW(rcr,s Approval Organizations 1.Underwriters Laboratories Inc. 2. Factory Mutual Research Corp. • Light Hazard Occupancies-No Limitations • Ordinary Hazard Occupancies-Groups 1 &2, Wet Systems Only 3. Underwriters Laboratories of Canada 4. NYC BS & A No. 587-75-SA 5. Loss Prevention Council • XLH, OHI and OHII Occupancies Only 6. NYC MEA 258-93-E Note: Unless otherwise indicated, ordinary hazard approvals are without limitations. 7/16" & 3/8" orifice sprinklers are limited to light hazard occupancies. ,..,.~,-, I C<><.!Pt.ll<G RCDUCff• J J,•· ;J/f" /JI/OP mPPU ro cc1t11<C /)/.,(NS,0,, ::rp,,;:: -j ,.:uwc -r,•,.~,~,.7/; \_L,J_/ '-'~'~' -~ •• ~" .. '.& :,/11· ½" NPT Non-Adjustable Inlet Figure 1 1" NPT Male-Adjustable Inlet Figure 2 1" NPT Female-Adjustable Inlet Figure 3 2. Product Description and Installation The Reliable Model G Recessed Sprinkler has been designed with ease of installation in mind. A choice of three inlets with up to one inch adjustment coupled with the Yi' escutcheon adjustment enables most system to be installed using pre-cut drop nipples. The adjustment can be accomplished after the ceiling installation and while the system is pressurized thereby providing sprin- kler protection before construction is completed. The Non-Adjustable inlet version (Figure 1) consists of the Reliable Model G Sprinkler with an attached cup recessed in the ceiling. A ceiling hole of 2 ¼" diameter is recommended. The Adjustable inlet version uses the same sprinkler as the Non-Adjustable inlet type except that 1" of additional adjustment is provided by a telescoping sprinkler inlet section that threads in or out of a stationary Coupling Reducer ( either 1" male or 1" female) as shown in figures 2 or 3. The Sprinkler-Cup assembly comes attached to the inlet Coupling Reducer and is retained from separa- tion past its maximum adjustment length by a snap ring. This combination is simply installed after the system drop nipple, elbow or tee has been "roughed in" to the dimensions shown in figures 2 or 3. Wrenching means are provided by hex flats on the coupling reducer as depicted in the figures--do not wrench on any other part of the sprinkler. After the ceiling tiles have been cut and installed in place (a 2¼" diameter hole is recommended), the sprinkler can be adjusted using the RC-1 Concealed Wrench. Figure 4 3. When using the wrench in this application, however, do not over-torque beyond the adjustment stops. Figure 4 shows a ½ " NPT non-adjustable inlet sprin- kler, with the attached sprinkler cup combination in- serted into the special Reliable Model RC-1 Installation Wrench. This wrench must be used. The wrenching pads of the sprinkler easily slip into the rectangular cut-outs of the wrench as the outside diameter locates the threaded cup. A½" drive ratchet can then be used for installation and tightening. Figure 5 shows the removal of the wrench. Care should be taken during this procedure to avoid hitting the de- flector with the wrench. The wrench should be lowered until it clears the threaded cup, and then moved horizon- tally to clear the sprinkler. The installation is completed by threading the escutcheon. on until it contacts the ceiling. To avoid leaving smudge marks on the ceiling, the Reliable Model FEA Flush Sprinkler Escutcheon Wrench should be used. See Bulletin 205 for details. Note: 1. Use hex wrench flats on Coupling Reducer to tighten Adjustable Sprinkler into fittings. Do not use RC-1 Wrench for this purpose. 2. Do not install the Model G Recessed Sprinkler in ceilings which have positive pressure in the space above. Figure 5 ) ) Product Description The Reliable Model G Automatic Sprinkler utilizes the center strut solder in compression principle of construction. The fusible alloy is captured in the cylinder of the solder capsule by a stainless steel ball. When the fusible alloy melts, the ball moves into the cylinder allowing the cylinder to fall away from the sprinkler. When this happens, the lever is released to spring free from the sprinkler so that all of the operating parts clear from the waterway allowing the deflector to distribute the discharging water. Except for the parts in the cylinder as mentioned above, the sprinkler components are made from copper based alloys for maximum corrosion protection. Lead plated, wax coated or wax over lead plated sprinklers are available for specially severe environments. Chrome plated sprinklers are available for decorative purposes. All sprinklers are individually hydrostatically tested. All sprinklers are identified as to their fusing point by markings that appear on several of the operating parts and by an identifying color that appears on the frame. Sprinkler Types Standard Upright -This deflector configuration is normally used with exposed piping installations. Water is distributed laterally and downward in a wide pattern approximating a hemisphere which is completely and uniformly filled with water in the form of small drops or spray. At a sprinkler height of 10 feet (3m), a circular area of approximately 20 feet (6.1 m) in diameter is covered by the water discharged at the minimum pressure. Standard Pendent -This deflector configuration is normally used where the space above the piping is not adequate or where a concealed piping installation is employed. The discharge characteristics of the standard pendent are virtually identical to the standard upright as described above. Large and Small Orifice -By varying the orifice size, a large or small orifice sprinkler is created that will distribute as much as40% more water or 65% less water than the normal ½" (15mm) orifice sprinkler. These sprinklers are identified by the orifice size that is stamped in the base of the sprinkler and by the pintle that extends from the deflector-the exceJ;.tion is the large orifice sprinkler with the¾" NPT (R ¼) inlet thread where the size of the inlet is sufficient to classify this sprinkler as one having a larger than standard orifice. Bulletin 11 0Q Model G Automatic Sprinklers Spray Upright, Spray Pendent And Conventional Pendent Small Orifice Upright (With Pintle Screw) Conventional Conventional -This deflector configuration is used pri- marily in those countries where the LPC installation rules have precedence. The sprin kier is designedtodistribute a portion of its water discharge upward against the ceil- ing with the balance downward. It may be installed in ei- ther the upright or the pendent position. Sprinklers with conventional deflectors are available with orifice sizes correspond·1ng to light, ordinary and extra-high hazard installations. Application and Installation Standard sprinklers are used in fixed fire protection system;: Wet, Dry, De luge or Preaction. Care must be exercised that the orificesizes,temperatureratings,deflectorstylesandsprinkler spacings are in accordance with the latest published stan- dardsofthe National FireProtectionAs soci ation orthe ap prov- ing authority having jurisdiction. The sprinklers must be installed with the Reliable Model D Sprinkler Wrench. Any other type of wrench may damage the sprinkler. The approvals or listings of Reliable Automatic Sprinklers by major approving organizations are shown in the tabulated list provided on the back of this bulletin. *Patent No. 4,440,234 The ReliableAutomaficSprink\erCo., Inc., 525 North MacQuesten Park way, Mount Vernon, New York 10552 0 0 Technical Data ~K" Factor Sprinkler Identification Sprinkler Number (SIN) Sprinkler Type us Metric Height Approvals ssu SSP Standard-Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position ½' (15 mm) Standard Orffice with ½' NPT (R½) Thread 5.62 81.0 2¼" (73 mm) 1, 2, 3, 4, 5, 6, 7 R1025 R1015 7,,(t ( 11 mm) Small Orifice(1) with ½" NPT (R½) Thread 4.24 61.0 3;Y,,• (81 mm) 1,3,7 R1023 R1013 ¾" (10 mm) Small OrificeI1I with½' NPT (R½) Thread 2.82 40.6 3;Y,s" (81 mm) 1,2,3, 7 R1021 R1011 Y,{ (8 mm) Small OriliceI1I with½" NPT (RY,) Thread 1.98 28.5 3r,, (81 mm) 1, 3,7 R1022 R1012 1½{ (20 mm) Large OrificE!1) with½" NPT (R½) Thread 7.96 114.7 3r,, (81 mm) 1, 2,3,7 Rt026 R1016 %," (20 mm) Large Orifice with ¾" NPT (R¾)Thread 8.20 118.2 21)(, (75 mm) 1, 2,3, 7 R1027 R1017 20 mm XHH with 20 mm Thread 8.20 118.2 75.4 mm 4,5,6 R1027 Rt017 10 mm XLH with 10 mm Thread 4.10 59.1 73mm 4, 5, 6 R1024 R1014 Conventional-Installed in Upright or Pendent Position 10mm XLH with 10mm Thread 4.10 59.1 73mm 5 R1074 15mm Standard Orifice with (RY.2) Thread 5.62 81.0 73mm 4,5,6 R1075 20mm XHH with (RY,) Thread 8.20 118.2 75.4 mm 4,5 R1077 m Identified by pintle extending above deflector. Sprtnkler height includes pintle extension. Temoerature Ratinas Maintenance Maximum Sprinkler Ambient Rating Temperature Frame (1) Classification 'F ·c 'F ·c Color Ordinary 135 57 100 38 Black Ordinary 165 74 100 38 Uncolored Intermediate 212 100 150 66 White High 286 141 225 107 Blue (1) Frame color does not apply to pmnted or plated sprinklers-Use sprinkler rating as identified on operating parts. Model G Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soapandwa ter, am mo nia or any other cleaning fluids, Remove any sprinkler that has been painted (other than factory applied) or dam aged in anyway.A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging untl used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Use only the Model D Sprinkler Wrench for sprin kier removal and in stal la tion. Any other type of wrench may damage the sprinkler, Finishes l1l Standard Finishes Bronze -All Temperature Ratings Chro:11& -All Temperature Ratings White -All Temperature Ratings Onlv Frame and Deflector are Painted Sneclal A'"' ... lication Finishes Bright Brass Plated -Only frame, deflector and cap are plated. 135'F (57°C), 165'F (74'C), 212'F (100'C) Temp. Rating. Black Plated -Only frame, deflector and cap are plated. All Temp. Ratings. Polyester Coated (2) -Only frame and deflector are coated. Lead Plated -165°F (74'C), 212'F (100'C) and 286°F (141'C) Temp. Ratings. Wax-Coated (3) -165'F (74°C) Clear Wax, 212°F (100'C) Brown Wax. Wax-Coated Over Lead Plated (3) -165°F (74.,C) Clear Wax, 212°F (100°C) Brown Wax. (1) Other colors and finishes are available. Consult factory for details. (2) UL listed and NYC MEA Approved only. 131 212'F (IOO'C) brown wax maybe used on 286'F (141'C) sprinklers when maximum ambient temperatures do not exceed 150°F (66'C). UL Listed, FM Approved, NYC MEA 258-93-E. Approval Organizations 1. Underwriters Laboratories, Inc. 2. Factory Mutual Research Coq:ioration 3. Underwriters' Laborator',es of Canada 4. Loss Prevention Council 5. Pleniere Assemblee 6. Verband der Schadenversicherer eV 7. N.Y.C. BS&A No. 587-75-SA N.Y.C. MEA 258-93-E Ordering Information Specify 1. Model G 2. Deflector • Upright • Pendent • Conventional 3. Nominal Orifice 4. lnletThread 5. Temperature Rating 6. Finish The equ'1pment presented in this bulletin is to be Installed In accordance with the latest pertinent Standards of the Nat!Onal Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes OI' ordinances whenever appl!cable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qual'lf'1ed and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by 'ftglla The Reliable Automatic Sprinkler Co., Inc. (800)431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices www.rejiablesprink'9r.com Internet Address Revis"ion lines ind·1cate updated or new data. EG. Pnnted r1 U.SA 12IOO PIN 999997CXX5 A~ofoo2-1 Reliable! Model G4 Concealed Automatic Sprinkler Bulletin 121 G OJ C ~ :, The Concealer® A Concealed Sprinkler With ½" or 1 ½" Adjustment Features 1 . ½" Total adjustment provided by economical standard inlet version. 2. 1 ½" Total adjustment provided by adjustable inlet versions. 3. Adjustable inlet version available with either 1" NPT male or female threads eliminating costly reducing coupling. 4. Simple sturdy cover attachment. 5. Smooth aesthetic ceiling profile. 6. As heat sensitive as an exposed sprinkler. 7. Available in white or other color painted or brass, chrome, or black plated finishes. 8. Ordinary and intermediate temperature ratings. 9. Multiple orifices for design flexibility. 10. Threaded cover does not require clips or springs. 11. Listed by Underwriters Laboratories Inc. and Underwriters' Laboratories of Canada. NY.C. BS&A No. 587-75-SA. 12. U.S. Patent No. 4,880,063. Application . . . --'"' _-0 ·-,. ·•'"'" The Reliable Model G4 Concealer is the most versatile concealed sprinkler available. It provides the best form of fire protection while offering an at- tractive appearance and ½ inch of cover adjustment for ease of installation. The ad-'--------~ justable 1" NPT inlet versions have one and _one half inches of total adjustment and they also elIm1nate the need for a reducing coupling. The small diameter cover plate is easily and positively attached and blends into the ceiling, concealing the most dependable fire protection available, an automatic sprinkler system. The Concealer® is designed for use where aesthetic appearance is important. Offices, hospitals, motels and restaurants are but a few of the applications where It can be used. It is available in different orifice sizes allowing G) the designer to optimize system performance, thereby achieving a most efficient installation. The Concealer® can eliminate the need for precise cutting of drop nipples. The threaded cover plate as- sembly can be adjusted without tools so it mates accu- rately with the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate as- sembly. Product Description The Reliable Model G4 Concealer uses the proven Model G fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is re- cessed into the ceiling and concealed by a flat cover plate. The cover plate and sprinkler cup assemblies are attached using a strong threaded engagement. This threaded engagement provides ½" of cover adjust- ment. The cover plate is attached to the skirt using an or- dinary temperature classification solder. This results in a strong cover plate assembly with an ordinary tempera- ture rating, and an intermediate temperature sprinkler which can be installed in 150°F environments. When the temperature at the ceiling rises, the solder holding the cover plate fuses, allowing the release of this part and thus exposing the sprinkler inside to the rising ambient temperature. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 • The subsequent fusing of the sprinkler element opens the waterway and causes the deflector to drop into position to distribute the discharging water. Any secure engagement of the threads between the cover plate and cup will assure that the drop-down deflector is properly located below the ceil- ing when a sprinkler operates. Installation Do not install The Concealer® in ceilings which have positive pressure in the space above. After a 2% inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model G4 Wrench. The wrench has drive tangs which insert into cup slots. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench tangs engage drive slots in the top of the cup (there are two sets of mat- ing drive slots in the cup). The sprinkler is then tightened into the pipe fitting. When inserting or removing the Standard Temperatures Classification Sprinkler Cover Plate Max. Ceiling Temp. Ordinary 135°F/57°C 135'F/57'C 100°F/38'C Ordinary 165'F/74'C 135'F/57'C 100'F/38'C Ordinary 165'F/74'C 165'F/74'C 100'F/38'C Intermediate 212'F/100'C 165'F/74'C 150'F/66'C Installation Data wrench from the sprinkler/cup assembly care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRIN- KLER/CUP ASSEMBLY. The adjustable inlet versions are similar to the stan- dard Model G4 except that an additional 1" of adjust- ment is provided by means of a telescoping inlet section that threads in or out of a stationary coupling reducer (either 1" male or 1" female) as shown in Fig- ures 2 or 3. These sprinklers must be installed before the ceiling is in place, by wrenching on only the cou- pling reducer hex flats. After the ceiling has been in- stalled with holes for the sprinkler, each telescoping inlet section is to be adjusted with the G4 Wrench. Fi- nal adjustment of each cover is made by hand turning the cover in the clockwise direction until it is tight against the ceiling. Ordering Information 1. Sprinkler Model 2. Temperature Rating 3. Nominal Orifice 4. Cover Plate Finish 5. Inlet Type Note: Unless otherwise specified, the 165"F sprinkler will be provided with the 165°F cover. Approval Organizations 1. Underwriters Laboratories, Inc. 2. NYC. BS&A No. 587-75-SA 3. Underwriters' Laboratories of Canada Total Nominal Sprinkler Inlet Adjustment Orifice "K" Factor Thread Approvals Note: Approvals are light and ordinary hazard, except for small orifice sprinklers which are limited to light hazard occupancies. The cup and skirt are fabricated from plated steel and are intended for interior non corrosive applications. us Non-Adjustable ½" ½"' (15mm) 5.62 Non--Adjustable ½" ¾6'' 4.24 , Non-Adjustable ½" ¾1' 2.82 Adjustable 1½" ½'" 5.53 Adjustable 1½" ¼ff' 4.24 Adjustable 1½" %" 2.72 Metric 81.0 )~" NPT 1,2,3 61.0 ,½" NPT 1,2,3 40.6 It NPT 1,2,3 79.7 1" NPT Male or Female 1,2,3 61.0 1" NPT Male or Female 1,2,3 39.2 i" NPT Male or Female 1,2,3 Installation Wrench Model G4 Sprinkler Wrench Cover Plate Finishes • Bronze • Bright Brass Plated • Chrome Plated • Black Plated • White Other colors and finishes are available, consult factory for details Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. )-,;" NPT Non-Adjustable Inlet Figure 1 1" NPT Male-Adjustable Inlet Figure 2 1" NPT Female-Adjustable Inlet Figure 3 The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standar?s of the National Fire Pr?tection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 70 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries Manufactured by The Reliable Automatic Sprinkler Co., Inc. Reliabl~ (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices www.reliablesprinkler.com Internet Address II\_ Recycled ~ Peper Revision lines indicate updated or new data E.G. Printed in U.S.A. 4/99 PIN 9999970014