HomeMy WebLinkAbout1856 PENTAS CT; ; CBR2024-0345; PermitBuilding Permit Finaled
Residential Permit
Print Date: 02/20/2025
Job Address:
Permit Type:
Parcel#:
Valuation:
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition:
Sprinkled:
Project Title:
1856 PENT AS CT, CARLSBAD, CA 92011-5137
BLDG-Residential Work Class:
2155210400 Track #:
$19,309.40 Lot#:
Project #:
Plan#:
Construction Type:
Orig. Plan Check#:
Plan Check It:
Alteration
Permit No:
Status:
(cityof
Carlsbad
CBR2024-0345
Closed -Finaled
Applied: 02/08/2024
Issued: 03/13/2024
Finaled Close Out: 02/20/2025
Final Inspection: 12/20/2024
INSPECTOR: Renfro, Chris
Kersch, Tim
Description: HORVATH : 335 SF REMODE OF KITCHEN AND BATH AND NEW EXTERIOR GLASS DOORS
Applicant:
PERM ITS IN MOTION
TERRY MONTELLO
4152 60TH ST
SAN DIEGO, CA 92115-6301
(619) 994-5557
FEE
BUILDING PLAN CHECK
REMODEL-RESIDENTIAL-OTHER
SB1473 -GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION -RESIDENTIAL (SMIP)
WINDOWS/DOOR-RESIDE NTIAL
Total Fees: $1,107.36 Total Payments To Date: $1,107.36
Contractor:
MARROKAL DESIGN AND REMODELING LLC
9842 RIVER ST
LAKESIDE, CA 92040-3114
(619) 441-9300
Balance Due:
AMOUNT
$434.85
$551.00
$1.00
$2.51
$118.00
$0.00
Please take NOTICE that approval of your project includes the "Imposit ion" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date t his permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to t his, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
t
( City of
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
Plan Check (!J?tz.zoiY-Ofil
Est. Value
PC Deposit
Date J/D5/ ~4 I
JobAddress1856 Pentas Ct. unit: APN:215-521-04-00 -----
CT /Project #: __________________ Lot#: 15 Year Built: _1_9_78 _______ _
BRIEF DESCRIPTION OF WORK: /St ~.f. ~t"f~ ft;.,wte>OE:-1.-, (~f 1.f. J'1.~,4Tll (:Z:f;/.40f)6l--4JD
I
rJ E-w f; ~ .-r e,t.1 qi. ~ i., /Jry~ ~ ot. ~ .
□ New SF: Living SF, ____ Deck SF, ___ Patio SF, ____ Garage SF __ _
Is this to create an Accessory Dwelling Unit? O Y O N New Fireplace? O YON, if yes how many? ___ _
J&'l Remodel:_3_35 ____ SF of affected area Is the area a conversion or change of use? O YO N
□ Pool/Spa: _____ SF Additional Ga s or Electrical Features? No -------------
□Solar: ___ KW, ___ Modules, Mounted:0Roof OGround, Tilt: ()YON, RMA:OY ON,
Battery:OYC N, Panel Upgrade: OY ON Electric Meter number: ------------
0th er:
APPLICANT (PRIMARY CONTACT) PROPERTY OWNER
Name~Wh 2 fl. 1 f:J1.te->( Mo~ Name:Cynthia Horvath
Address:9414 l~y-mt~~~Addres_s_:_1-_8-5:6:_P-_e-n:t_a-_s-_C-_t-.:::::::::::::::::::::::::~-
City:San Diego State:CA Zip~2426 11-IK'"°City:_C_a_rl_sb_a_d _______ .State:CA Zip:._9_2_01_1 __ _
Phone.858 510 9900-1a: (e~J-f'f+ ~ Phone: ___________________ _
Email:mJ!1,mcao@n:ia,rekel.e:em:f?@')t>1'js ~ Email: ___________________ _
pel')k i-fs t \\ \11\ <if, o\l • lOJI-)
DESIGN PROFESSIONAL CONTRACTOR OF RECORD
Name:Mark Duncan
Address:9474 Kearny Villa Rd. Suite 205
City: San Diego State: CA Zip:_9_2_12_6 __ _
Phone: 858-549-9000x16
Email: mduncan@marrokal.com
Architect State License: N/A ------------
Business Name: Marrokal Design & Remodeling
Address: 9842 River St.
City: Lakeside State: CA Zip:_9_20_4_0 ____ _
Phone: 619-441-9300
Email: __________________ _
CSLB License#: 1010116 Class:B ·-------
Carlsbad Business License# (Required): BLOS1243155
APPLICANT CERT/FICA TION: I certify that I have read the application and state that the above information is correct and that the information of the plans is accurate. I
""' ,o comply w;<h o/1 aw o,d;ooom ood '"" ,,~ ,ek,Uog ,o bo;ld;,g '""ro'"'"· ~ _CJ___
NAME (PRINT}: Mark Duncan SIGN:~ ~ DATE: '2, -I-2-f:
1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov
REV. 04122
~
THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _
A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING
THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE.
(OPTION A): LICENSED CONTRACTOR DECLARATION:
I herebyaf firm under penal tyof perjury that I am licensed under provisions of Chapter 9 ( commencing with Section 7000) of Division 3
of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the
following declarations (CHOOSE ONE):
Di have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued. Policy No .. _________________________________________ _
-OR--• •
~I have and will maImain worKer s compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: Insurance Company Name: 'N'\ ~ • ~ "
Policy No:1' ~ o ~ O ~~ 0 d..\ • '-\ \ ~------------Expiration Date:. \ / \ I 16
-OR-
D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
Interest and attorney's fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of t he work this permit is issued (Sec. 3097 (i) Civil Code).
lender's Name:. ______________________ Lender's Address: _____________________ _
CONTRACTOR CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and
utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are
not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show
the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed
use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. "';::::::::~;: ··:::::~·-:::•~c;•;'"" ·":;~:::::~·:"'"" .. "' ~. -::IJ"ct"" ""''" ::~:~/51 ~ vi
Note: If the person signing above is an authorized agent for the contra t • d tter of authorization on contractor letterhead. ' .
-OR-
(OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such
work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
-OR-
DI, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
-OR-
DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
AND,
D FORM 8-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed
contractors./ understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is
submitted or at the following Web site: http: I I www.leginfo.ca.gov/ ca law. html.
OWNER CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility
easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved
for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct
dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each
building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All
improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted.
NAME (PRINT):
Note: If the erson sl nin above is an authorized a ent for the ro ert owner include form B-62 si ned b ro ert owner.
SIGN: __________ DATE: ______ _
1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov
2
REV. 04/22
C\(.(_
Building Permit Inspection History Finaled
(c ity of
Carlsbad
PERMIT INSPECTION HISTORY for (CBR2024-0345)
Permit Type: BLDG-Residential Application Date: 02/08/2024 Owner:
Work Class: Alteration Issue Date: 03/13/2024 Subdivision: CARLSBAD TCT#72-34 UNIT#01
Status: Closed -Finaled Expiration Date: 04/07/2025 Address: 1856 PENTAS CT
IVR Number: 54670 CARLSBAD, CA 9201 1-5137
Scheduled Actual Inspection Type Inspection No . Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
08/15/2024 08/15/2024 BLDG-21 258189-2024 Passed Chris Renfro Complete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-31 258190-2024 Passed Chris Renfro Complete
Underground/Conduit•
Wiring
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-SW-Pre-Con 257987-2024 Passed Chris Renfro Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
08/19/2024 08/19/2024 BLDG-11 258275-2024 Partial Pass Chris Renfro Re inspection Incomplete
Foundatlon/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Need third-party special inspection on Yes
epoxy of HDU4 bolts.
BLDG-12 Steel/Bond 258274-2024 Passed Chris Renfro Complete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Need third-party special Inspection on Yes
epoxy of HDU4 bolts
09/25/2024 09/25/2024 BLDG-18 Exterior 262079-2024 Passed Tim Kersch Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-23 262078-2024 Passed Tim Kersch Complete
Gas/Test/Repairs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-27 Shower 262077-2024 Passed Tim Kersch Complete
Pan/Tubs
Thursday, February 20, 2025 Page 1 of 3
PERMIT INSPECTION HISTORY for (CBR2024-0345)
Permit Type: BLDG-Residential Application Date: 02/08/2024 Owner:
Work Class: Alteration Issue Date: 03/13/2024 Subdivision: CARLSBAD TCT#72-34 UNIT#01
Status: Closed -Finaled Expiration Date: 04/07/2025 Address: 1856 PENTAS CT
IVR Number: 54670 CARLSBAD, CA 9201 1-5137
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 262076-2024 Passed Tim Kersch Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
BLDG-SW-Inspection 262279-2024 Partial Pass Tim Kersch Reinspection Incomplete
Checklist Item COMMENTS Passed
Are erosion control BMPs Yes
functioning properly?
Are perimeter control BMPs Yes
maintained?
Is the entrance stabilized to Yes
prevent tracking?
Have sediments been tracked Yes
on to the street?
Has trash/debris accumulated Yes
throughout the site?
Are portable restrooms Yes
properly positioned?
Do portable restrooms have Yes
secondary containment?
10/01/2024 10/01/2024 BLDG-16 Insulation 262672-2024 Passed Chris Renfro Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
10/07/2024 10/07/2024 BLDG-17 Interior 263338-2024 Passed Chris Renfro Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/20/2024 12/20/2024 BLDG-Final Inspection 271668-2024 Passed Chris Renfro Complete
Thursday, February 20, 2025 Page 2 of 3
PERMIT INSPECTION HISTORY for (CBR2024-0345)
Permit Type: BLDG-Residential
Work Class: Alteration
Status: Closed -Finaled
Application Date: 02/08/2024 Owner:
Issue Date: 03/13/2024 Subdivision: CARLSBAD TCT#72-34 UNIT#0 1
Expiration Date: 04/07/2025 Address: 1856 PENTAS CT
CARLSBAD, CA 92011-5137 IVR Number: 54670
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date
Thursday, February 20, 2025
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
Status
Passed
Yes
Yes
Yes
Yes
Yes
Page 3 of 3
solidforms . . eng1neer1ng
9474 Kearny Villa Rd, Suite 215, San Diego, CA 92126
Evan Coles, P.E. (858) 376-7734
evan@solidformseng.com
Project: Horvath Residence
Address: 1856 Pentas Ct Carlsbad, CA 92011
CORRECTION #S1:
Correction
Responses
February 26, 2024
Project#: 24-012
See revised special inspection notes and requirements at sheet Sl.
CORRECTION #S2:
See revised detail for dowls provided between the new and existing footings.
CORRECTION #S3:
See revised plans and calculations provided. We have now added more shear to reduce the uplift. See epoxy calculations
attached blow.
Lateral Design
Upper Level
Seis. Area (tt2) =
Shear line Len.Tot. (ft) =
Wind Relative to Ridge =
Wind Lengths:
LH = Vert.Trib Height (ft) =
Lw = Dist to Adj Gridline (ft) =
Shear Above: line =
VxAbove (Seis/Wind) =
0/orrib. of Load =
VxAbv.Trib. (Seis/Wind) =
Wood Shearwalls =
Length =
Load Type =
Shear Load (lbs) =
Wall DLOist. (psf) =
Resis. DLo;st, (plf) =
Resis. DLPoint (lbs) =
DLPolnt Dist (ft) =
Momentar (lb-ft) =
1MomentResist. (lb-ft) =
Uplift (lbs) =
UpliftAbove =
Upli~et. =
Left Holdown =
Right Holdown =
N-S Line:
1160
4.5
Perpendicular
Left Right
I 8.0
T 3s.o
-
--
w,
5
Seis. I Wind
734 896
16
5873 7168
782 960
1131 1380
1131 1380
Per Plan
Per Plan
B
p = 1.0
Sos= 0.797
Plate Ht. (ft) = 8
Lwan Tot. (ft) = 7.5
-
--
W2
2.5
Seis. I Wind
367 448
16
2936 3584
195 240
1371 1672
1371 1672
Per Plan
Per Plan
-
0
-
-
-
-
Shearwall Seis. Wind
Strength Design Seis. Force: fx = 2.7 psf
16.0 psf
lbs
1344 lbs
lbs
-
W3
I
Maximum Wind Pressure: Px =
Vl<Seis(ASo> = Area/2*Fx*p*0.7 = 1101
xWlnd = LH*Lw/2*P.*0.6 = V
r>lx (Above) =
VxTotal = 1101 1344 lbs
3.5:1 = (h/2L)* VJ L = 235 179 plf
-
Use Shearwall Type= @
with LTP4 clips @ 12 "o.c. 45%
for entire length of grid line B
W◄ Ws w6
I I I
0 0 0 0 0 0 0
-------
-------
-------
-------
SIMPSON
Strong-Tie
Anchor Designer™
Software
Version 2.8.7094.0
1.Project iotormat;on
Customer company:
Customer contact name:
Customer e-mail:
Comment:
2. Input Data & Anchor Parameters
General
Design method:ACI 318-14
Units: Imperial units
Anchor Information:
Anchor type: Bonded anchor
Material: F1554 Grade 36
Diameter (inch): 0.625
Effective Embedment depth, h,1 (inch): 12.500
Code report: ICC-ES ESR-2508
Anchor category: -
Anchor ductility: Yes
hm;n (inch): 15.63
Cac (inch): 33.01
Cm;n (inch): 1. 75
Sm;n (inch): 3.00
Recommended Anchor
Anchor Name: SET-XP®-SET-XP w/ 5/8"0 F1554 Gr. 36
Code Report: ICC-ES ESR-2508
an
-a
!>.. I I ! :: . I i ~ ... ti -· en ff ·~
..... . ,. l
Company:
Engineer:
Project:
Address:
Phone:
E-mail: ------~
Project description:
Location:
Fastening description:
Base Material
Concrete: Normal-weight
Concrete thickness, h (inch): 16.00
State: Cracked
Compressive strength, f c (psi): 2500
4-'c,v: 1.0
Reinforcement condition: B tension, B shear
Supplemental reinforcement: Not applicable
Reinforcement provided at corners: No
Ignore concrete breakout in tension: No
Ignore concrete breakout in shear: No
Hole condition: Dry concrete
Inspection: Continuous
Temperature range, Short/Long: 150/11 0"F
Ignore 6do requirement: Not applicable
Build-up grout pad: No
I Date: I 8/15/2019
I Page: I 1/5
---
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
S,mpson S,rong-T,e Company Inc 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
SIMPSON
Strong-Tie
Load and Geometry
Anchor Designer™
Software
Version 2.8.7094.0
Load factor source: ACI 318 Section 5.3
Load combination: not set
Seismic design: Yes
Anchors subjected to sustained tension: No
Ductility section for tension: 17.2.3.4.2 not applicable
Ductility section for shear: 17 .2.3.5.2 not applicable
Oo factor: not set
Apply entire shear load at front row: No
Anchors only resisting wind and/or seismic loads: Yes
Strength level loads:
Nu, [lb]: 4550
Vuax [lb]: 0
Vu,y [lb]: 0
<Figure 1 >
0lb
Company:
Engineer:
Project:
Address:
Phone:
E-mail:
45501b z
l Date: J a11s12019
I Page: I 2/5
-~ ~ --
0lb
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
Simpson Strong-T·e Company Inc 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
SIMPSON
Strong-Tie
<II)
<Figure 2>
Anchor Designer™
Software
Version 2.8.7094.0
Company: 7 Date: l 8/15/2019
Engineer: I Page: I 3/5
Project:
Address:
Phone:
E-mail:
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
Simpson Strong-T,e Company Inc 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
SIMPSON
Strong-Tie
Anchor Designer™
Software
Version 2.8.7094.0
3. Resulting Anchor Forces
Company:
Engineer:
Project:
Address:
Phone:
E-mail:
Anchor Tension load,
Nua (lb)
Shear load x,
Vuax (lb)
4550.0
Sum 4550.0
Maximum concrete compression strain (%o): 0.00
Maximum concrete compression stress (psi): 0
Resultant tension force (lb): 4550
Resultant compression force (lb): 0
0.0
0.0
Eccentricity of resultant tension forces in x-axis, e'Nic (inch): 0.00
Eccentricity of resultant tension forces in y-axis, e'Nv (inch): 0.00
4. Steel Strength of Anchor in Tension (Sec. 17,4.11
N .. (lb) ¢ ¢N,. (lb)
13110 0.75 9833
5. Concrete Breakout Strength of Anchor in Tension (Sec. 17.4.21
No= kcA.✓f'cha,'-5 (Eq. 17.4.2.2a)
kc f'c (psi) h., (in)
17.0 1.00 2500 12.000 35334
0.75¢Nco = 0.75¢ (Ar,ic/ ANco) 'Pad,N 'Pc.N'f/cpr,iNo (Sec. 17.3.1 & Eq. 17.4.2.1a)
ANc (in2) ANco (in2 Cam;n (in) 'f'ad,N 'Pc.N
432.00 1296.00 6.00 0.800 1.00
6. Adhesive strength of Anchor ia Tension 1sec. 17,4.51
11<,.,(psi) fsho,Herm K,., aN.sttis
435 1.72 1.00 1.00
Noa= A.at'crtrdahar(Eq. 17.4.5.2)
A.a t'cr (psi) d. (in) har (in) Noa (lb)
1.00 748 0.63 12.500 18364
0.75¢,Na = 0.75¢, (A111a/ A111a-0) 'f'ad111a 'Pg,,111aNoa (Sec. 17.3.1 & Eq. 17.4.5.1 a)
A111a (in2) ANaO (in2) C111a (in) Ca.mm (in) 'Pad.Na
193.11 258.98 8.05 6.00 0.924
Shear load y,
Vuay (lb)
0.0
0.0
'f'cpN No (lb)
1.000 35334
n,_.,(psi)
748
Nao (lb)
1.000 18364
I Date: I 8/15/2019
I Page: I 4/5
Shear load combined,
✓(Vuax)2+(Vuay)2 (lb)
0.0
0.0
0.75¢Nco (lb)
0.65 4593
0.75¢N, (lb)
0.65 6166
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
Simpson Strong-T,P Como~ny Inc 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
SIMPSON
Strong-Tie
11. Results
Anchor Designer™
Software
Version 2.8.7094.0
11. Interaction of Tensile and Shear forces (Sec. D. 717
Company:
Engineer:
Project:
Address:
Phone:
E-mail:
Tension Factored Load, Nu, (lb) Design Strength, 0Nn (lb)
Steel 4550 9833
Concrete breakout
Adhesive
4550
4550
4593
6166
Ratio
0.46
0.99
0.74
SET-XP w/ 5/8"0 F1554 Gr. 36 with hef = 12.500 inch meets the selected design criteria.
ALLOWABLE UPLIFT= 4593 (0.7) = 3200 lbs MAX.
I Date: I 8/15/2019
I Page: j 5/5
Status
Pass
Pass (Governs)
Pass
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
Simpson Strong-Te Company Inc 5956 W. Las Positas Boulevard Pleasanton. CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
SIMPSON
Strong-Tie
Anchor Designer™
Software
Version 2.8.7094.0
1.Prolect Information
Customer company:
Customer contact name:
Customer e-mail:
Comment:
2. input Data & Anchor Parameters
General
Design method:ACI 318-14
Units: Imperial units
Anchor Information:
Anchor type: Bonded anchor
Material: F1554 Grade 36
Diameter (inch): 0.625
Effective Embedment depth, h,, (inch): 12.500
Code report: ICC-ES ESR-2508
Anchor category: -
Anchor ductility: Yes
hmln (inch): 15.63
Cao (inch): 33.01
Cm1n (inch): 1.75
Sm1n (inch): 3.00
Recommended Anchor
Anchor Name: SET-XP® -SET-XP w/ 5/8"0 F1554 Gr. 36
Code Report: ICC-ES ESR-2508
on )
Company:
Engineer:
Project:
Address:
Phone:
E-mail:
Project description:
Location:
Fastening description:
Base Material
Concrete: Normal-weight
Concrete thickness, h (inch): 16.00
State: Cracked
Compressive strength, f, (psi): 2500
41,.v: 1.0
Reinforcement condition: B tension, B shear
Supplemental reinforcement: Not applicable
Reinforcement provided at corners: No
Ignore concrete breakout in tension: No
Ignore concrete breakout in shear: No
Hole condition: Dry concrete
Inspection: Continuous
Temperature range, Short/Long: 150/110°F
Ignore 6do requirement: Not applicable
Build-up grout pad: No
I Date: I 8/15/2019
I Page: I 1/5
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
S,mpson Strong-T,e Company Inc 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
SIMPSON
Strong-Tie
Anchor Designer™
Software
Version 2.8.7094.0
Load and Geometry
Load factor source: ACI 318 Section 5.3
Load combination: not set
Seismic design: Yes
Anchors subjected to sustained tension: No
Ductility section for tension: 17.2.3.4.2 not applicable
Ductility section for shear: 17 .2.3.5.2 not applicable
Oo factor: not set
Apply entire shear load at front row: No
Anchors only resisting wind and/or seismic loads: Yes
Strength level loads:
Nua [lb): 2650
Vu., [lb]: 0
Vuay [lb): 0
<Figure 1 >
Company: I Date: I 8/15/2019
Engineer: I Page: I 2/5
Project:
Address:
Phone:
E-mail:
l6so1b
Olb
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
Simpson Strong-Tie Compa~y Inc 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
SIMPSON
Strong-Tie
Anchor Designer™
Software
Version 2.8.7094.0
3. Resulting Anchor Forces
Company:
Engineer:
Project:
Address:
Phone:
E-mail:
Anchor Tension load,
Nua (lb)
Shear load x,
Vuo (lb)
2650.0
Sum 2650.0
Maximum concrete compression strain (%.): 0.00
Maximum concrete compression stress (psi): 0
Resultant tension force (lb): 2650
Resultant compression force (lb): O
0.0
0.0
Eccentricity of resultant tension forces in x-axis, e'N, (inch): 0.00
Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00
4, Steel Strength of Anchor in Tension {Sec. 17.4.11
N,, (lb) ¢ ¢N .. (lb)
13110 0.75 9833
s. Concrete Breakout Strength of Anchor in Tension 1sec. 17.4.21
Nb= k,).,✓f',h,,u (Eq. 17.4.2.2a)
kc )., f'c (psi) h,, (in) Nb (lb)
17.0 1.00 2500 12.000 35334
0.75¢N,b = 0.75¢ (ANcl ANco) 'f',d.N 'Pc.N 'f'cp.NNb (Sec. 17.3.1 & Eq. 17.4.2.1 a)
ANc (in2) ANco (in2 Ca.mm (in) 'f'ed.N 'f'c.N
279.00 1296.00 1.75 0.729 1.00
6, Mhesi~e Strength 2! Anchor in Tension 1sec. 17,4,51
t\cr = n.,crfshort~termK sataN seis
1k.cr (psi) fshorl.ferm Ksat UNse,is
435 1.72 1.00 1.00
N ba = Aarcrndah,r(Eq. 17.4.5.2)
"• Tc, (psi) da (in) h,r (in) Nb, (lb)
1.00 748 0.63 12.500 18364
0.75¢,N. = 0.75¢, (AN,/ ANao)'Pod.Na'l'cp.NaNba (Sec. 17.3.1 & Eq. 17.4.5.1a)
AN, (in2) ANao (in2) CNa (in) Ca.mm (in) lfled,Na
130.26 258.98 8.05 1.75 0.765
Shear load y,
Vuay (lb)
0.0
0.0
'f'cp.N
1.000
11<.cr (psi)
748
'f'p,Na
1.000
Nb (lb)
35334
Nao (lb)
18364
I Date: I 8/15/2019
I Page: l 4/5
Shear load combined,
✓{Vua,)2+(Vuay)2 (lb)
0.0
0.0
¢ 0.75¢Ncb (lb)
0.65 2704
¢ 0.75¢N. (lb)
0.65 3446
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
S,mpson Strong-Te Company Inc 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
SIMPSON
Strong-Tie
<Figure 2>
Anchor Designer™
Software
Version 2.8.7094.0
Company:
Engineer:
Project:
Address:
Phone:
E-mail:
10.25 1.75
LI")
N
LI")
0 0
cx:i .....
I Date: I 8/15/2019
I Page: I 3/5
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
Simpson Strong-Tie Company Inc 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
SIMPSON
Strong-Tie
11. Results
Anchor Designer™
Software
Version 2.8.7094.0
11. Interaction of Tensile and Shear Forces /Sec. P,717
Company:
Engineer:
Project:
Address:
Phone:
E-mail:
Tension Factored Load, Nua (lb) Design Strength, 0 Nn (lb)
Steel 2650 9833
Concrete breakout
Adhesive
2650
2650
2704
3446
Ratio
0.27
0.98
0.77
SET-XP w/ 5/8"0 F1554 Gr. 36 with hef = 12.500 inch meets the selected design criteria.
ALLOWABLE UPLIFT= 2704 (0.7) = 1890 lbs MAX.
I Date: I 8/15/2019
I Page: I 5/5
Status
Pass
Pass (Governs)
Pass
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
S,mpson Strong-Te Company Ire. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
. ,,. True North
COMPLIANCE SERVICES
March 5, 2024
City of Carlsbad
Community Development Department -Building Division
1635 Faraday Ave.
City of Carlsbad -FINAL REVIEW
City Penn it No: CBR2024-0345
True North No.: 23-018-113
Carlsbad, CA 92008
Plan Review: Residential Remodel Kitchen
Address: 1856 Pentas Ct, Carlsbad CA
Applicant Name: Terry Montello
Applicant Email: pennits@pennitsinmotion.com
OCCUPANCY AND BUILDING SUMMARY:
Occupancy Groups: R-3/U
Occupant Load: N/ A
Type of Construction: V-B
Sprinklers: No
Stories: Two
Area of Work (sq. ft.): Remodel: 336 sq. ft.
The plans have been reviewed for coordination with the pennit application.
Valuation:
Scope of Work:
Floor Area:
Confirmed
Confirmed
Confirmed
Attn: Building & Safety Department,
True North Compliance Services, Inc. has completed the final review of the following documents for the project
referenced above on behalf of the City of Carlsbad:
l.
2.
Drawings: Electronic copy dated February I, 2024, by Marrokal Design.
Structural Calculations: Electronic copy dated January 24, 2024, by Evan A. Coles.
The 2022 California Building, Mechanical, Plumbing, and Electrical Codes (i.e., 2021 IBC, UMC, UPC, and 2020
NEC, as amended by the State of California), 2022 California Green Building Standards Code, 2022 California
Existing Building Code, and 2022 California Energy Code, as applicable, were used as the basis of our review.
Please note that our review has been completed and we have no further comments, however, we bring the
following to your attention:
I. In order to expedite the pennitting process, we have made annotations (in red ink) to A8.
True North Compliance Services, Inc.
8369 Vickers Street, Suite 207, Son Diego, CA 92111
T / 562.733.8030
solidforms . . eng1neer1ng
9474 Kearny Villa Rd, Suite 215, San Diego, CA 92126
Evan Coles, P.E. (858) 376-7734
evan@solidformseng.com
STRUCTURAL CALCULATIONS
Horvath Residence
1856 Pentas Ct, Carlsbad, CA 92011
01-24-2023 : Project# 24-012
Table of Contents
Design Criteria & Loads ......... ..
Gravity Analysis & Design .... ..
Lateral Analysis & Design ..... ..
CBR2024-0345
1856 PENTAS CT
> 1---0
Foundation Analysis & Desigr HORVATH : 335 SF REMODE OF KITCHEN AND BATH AND
NEW EXTERIOR GLASS DOORS
2155210400
2/8/2024
CBR2024-0345
Design Criteria
Building Code:
Concrete:
Masonry:
Mortar:
Grout:
Reinforcing Steel:
Structural Steel:
Bolting:
Welding:
Wood:
Soil:
Desig_n Loads
Load 1
DL Asphalt Shingle Roof
Plywood
Joists
Insulation
Drywall
Electrical/Mech./Misc.
Other
Total DL
LL Residential Roof
Total Load
Load 3
solidforms
engi n eering
2021 IBC/2022 CBC -ASCE / SEI 7-16
ACI 318-19 [fc = 2500 psi -No Special Inspection Req.'d (U.N.O.)]
TMS 402-16/ACI 530-16 [Normal Wt.-ASTM C90-fm=1500 psi-Spec. Insp. Req.'d]
ASTM C270 [fc = 1800 psi Type S]
ASTM C476 [fc = 2000 psi]
ASTM A615 [Fy = 40 ksi For #4 Bars & Smaller/ Fy = 60 ksi For #5 Bars & Larger]
AISC 360-16, 15th Edition
W Shapes (I Beams): ASTM A992, High Strength, Low Alloy, Fy = 50 ksi
HSS Shapes (Rect.): ASTM AS00, Carbon Steel, Fy = 46 ksi
HSS Shapes (Round): ASTM AS00, Carbon Steel, Fy = 42 ksi
Pipe Shapes: ASTM A53, Grade B, Carbon Steel, Fy = 35 ksi
All other steel: ASTM A36, Fy = 36 ksi
A307 / A325-N / A490-N (Single Plate Shear Conn.)
E70 Series Typ. (E90 Series for A615 Grade 60 Reinforcing Bars)
Shop welding to be done in an approved fabricator's shop.
Field welding to have continuous Special Inspection.
NDS-2018
Soil Classification (Table 1806.2):
Allowable Bearing Pressure =
Lateral Bearing Pressure =
Active Pressure =
At-rest Pressure =
Coefficient of Friction =
esf Load 2
4.0 DL Carpet & Pad Floor
1.5 Plywood
3.5 Joists
1.5 Insulation
2.5 Drywall
1.0 Elec./Mech./Misc.
0.0 Other
14 Total DL
20 LL Residential Floor
34 Total Load
Load 4
(SW, SP, SM, SC, GM, & GC)
1500 psf (Table 1806.2)
150 psf/ft (Table 1806.2)
30 psf/ft (Table 1610.1)
60 psf/ft (Table 1610.1)
0.25 (Table 1806.2)
esf Int. Wall
4.0 DL Drywall
1.5 2x4 Studs @ 16"o.c.
3.5 Misc.
1.5 other
2.5 Total Load
1.0
0.0 Ext. Wall 1
14 DL Stucco
40 2x4 Studs @ 16"o.c.
54 Drywall
Insulation
Misc.
Other
Total Load
Ext. Wall 2
Page 1 of 7
01/24/24
esf
5.0
1.0
1.0
7
esf
10.0
1.0
2.5
1.5
1.0
16
Multiple Simple Beam
UC#: KW-06015083, Build:20.23.08.30
Descri tion: ROOF GRAVITY
Wood Beam Design: RB-1
solid forms
enginee r ing
Solid Forms Engineering
Page 2 of 7
01/24/24
Project File: HORVATH.ec6
(c) ENERCALC INC 1983-2023
Calculations per NOS 2018, IBC 2021, ASCE 7-16
BEAM Size:
Wood Species :
3.5x16.0, Parallam PSL, Fully Braced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
iLevel Truss Joist Wood Grade : Parallam PSL 2.0E
Fb -Tension
Fb-Compr
2900 psi Fe -Prll 2900 psi Fv 290 psi Ebend-xx 2000 ksi Density 45.07 pcf 2900 psi Fe -Perp 750 psi Ft 2025 psi Eminbend -xx 1016.535 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0140, Lr= 0.020 k/ft, Trib= 13.50 ft
1Point: D = 0.80, Lr= 1.10 k@5.250 ft
Design Summary
Max fb/Fb Ratio =
fb : Actual : Fb : Allowable :
0.472 · 1 1,658.90 psf at
3,511 .07 psi
+D+Lr
6.667 ft in Span # 1
Load Comb :
Max fv/FvRatio =
fv : Actual: Fv : Allowable :
Load Comb :
Max Reactions (k)
Left Support
Right Support
0.329: 1
119.29 psi at 362.50 psi
+D+Lr
Q lJ: .L.
2.19 2.90
1.91 2.52
Wood Beam Design: RH-1
0.000 ft in Span# 1
E .t:i
16.0 ft
ax e ectIons
Transient Downward 0.225 in
Ratio 852
Transient Upward
Ratio
LC: Lr Only
0.000in
9999
LC:
Total Downward 0.395 in
Ratio 485
LC: +D+Lr
Total Upward 0.000 in
Ratio 9999
LC:
Calculations per NOS 2018, IBC 2021, ASCE 7-16
BEAM Size:
Wood Species :
3.5x9.25, Parallam PSL, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
iLevel Truss Joist Wood Grade : Parallam PSL 2.0E
Fb -Tension
Fb -Compr
2900 psi Fe -Prll 2900 psi Fv 290 psi Ebend-xx 2000 ksi
2900 psi Fe -Perp 750 psi Ft 2025 psi Eminbend -xx 1016.535 ksi
Density 45.07 pcf
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0140, Lr = 0.020 k/ft, Trib= 12.50 ft
Design Summary
Max fb/Fb Ratio =
fb : Actual :
0.367; 1 1,307.71 psi at
3,558.89 psi
+D+Lr
Fb : Allowable :
Load Comb :
Max fv/FvRatio = fv : Actual : Fv : Allowable :
Load Comb:
Max Reactions (k)
Left Support
Right Support
0.235: 1 85.35 psi at 362.50 psi
+D+Lr
Q Lr .L.
0.93 1.25
0.93 1.25
5.000 ft in Span# 1
9.233 ft in Span # 1
'1J. E .t:i
ax e ectIons
3.5x9.25
10.0 ft
Transient Downward 0.122 in
Ratio 979
LC: Lr Only
Transient Upward 0.000 in
Ratio 9999
LC:
Total Downward
Ratio
Total Upward
Ratio
0.213 in
562
LC: +D+Lr
0.000 in
9999
LC:
Multiple Simple Beam
LI # : KW-06015083, Build:20.23.08. 30
Wood Beam Design : RH-2
solidforms
enginee r ing
Solid Forms Engineering
Page 3 of 7
0 1/24/24
Project File: HORVATH.ec6
(C) ENERCALC INC 1983-2023
Calculations per NOS 2018, IBC 2021, ASCE 7-16
BEAM Size : 3.5x14.0, Parallam PSL, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
iLevel Truss Joist Wood Grade : Parallam PSL 2.0E Wood Species :
Fb -Tension
Fb -Compr
2900 psi Fe -Prll 2900 psi Fv 290 psi Ebend-xx 2000 ksi
2900 psi Fe -Perp 750 psi Ft 2025 psi Eminbend -xx 1016.535 ksi
Density 45.07 pct
Applied Loads
Beam self weight calculated and added to loads
1 Point: D = 0.80, Lr = 1.10 k@ 3.250 ft
2Point: D = 2.40, Lr = 3.30 k@ 4.750 ft
Design Summary
Max fb/Fb Ratio =
fb: Actual:
Fb : Allowable :
0.737 • 1
2,193.30 psf at
2,974.48 psi
+D+Lr
4.750 ft in Span# 1
Load Comb:
Max fv/FvRatio = fv: Actual :
Fv : Allowable :
Load Comb:
Max Reactions (k)
Left Support Right Support
0.424: 1 153.61 psi at
362.50 psi
+D+Lr
Q .Lr
2.18 2.86 1.22 1.54
J.
0.000 ft in Span# 1
'1:J. E 1:1
ax Deflections
Transient Downward
Ratio
12.50ft
0.170in
882
LC: Lr Only
Transient Upward 0.000 in
Ratio 9999
LC:
Total Downward
Ratio
Total Upward
Ratio
0.299 in
502
LC: +D+Lr
0.000 in
9999
LC:
Seismic Design
solidforms
engineering
Page 4 of 7
01/24/24
Design Variables Base Shear Calculation (ASCE 7-16 Sec. 12.8 & Supplement 2)
Latitude= 33.10 (12.8-2) V= CsW Cs= S0s*I/R
Longitude = -117.27
Site Class= D
Occupancy= II Table 1.5-1
(12.8-3) forTsT,: So1*I/(RT) Where: Cs max. = forT>T,: So1*TL*I/(RT2) (12.8-4)
Seis. category = D Table 11.6-1 & 2
I= 1.0 Tables 1-1 & 11.5-1
R = 6.5 Table 12.2-1
(12.8-5) for S,<0.6:0.044S0sI~0.01 Where: Cs min. = (12.8-6) tor s1~0.6: 0.SS1 *I/R
Ss = 0.996 Section 11.4.1
S1 = 0.362 Section 11.4.1 DL Area Len.
Fa= 1.200 Table 11.4-1 Material (psf) {tt2} (ft)
fv = 1.938 Table 11.4-2 Load 1 14 2880
SMs = Ss*Fa = 1.195 (11.4-1)
SMl = S1*Fv = 0.702 (11.4-2)
._ -~~ a. Q) Ext. Wall 1 16 300 ::::> _,J
Sos = 2/3*SMs = 0.797 (11.4-3) Int. Wall 7 150
Soi = 2/3*SM1 = 0.468 (11.4-4) 2880
All other structural systems Table 12.8-2
¼= 0.02 Table 12.8-2
X= 0.75 Table 12.8-2
T L= 8 Figure 22-15
Ta= ¼*hnx = 0.112 (12.8-7)
T =Ta= 0.112 Section 12.8.2
hn = 10.0 Section 12.8.2.1
Cs= 0.123 Section 12.8.1.1
k= 1 Section 12.8.3
<=ct = 4 Table 12.2-1
t:,.a = hsx * 0.025 Table 12.12-1
Vertical Distribution of Forces & Allowable Elastic Drift (ASCE 7-16, Sec. 12.8.3 & 12.8.6)
Level Wx hx h/ Wxh/ Fx Fx (psf) % p Oxe a11ow.
Upper Level 66.6 10.0 10.0 666 8.2 2.8 100% Yes 0.750
66.6 666 8 3
Level Forces (ASCE 7-16, Sec. 12.10.1.1)
Level Wx IWx Fx IFx Fpx Fpx {ASD) Where:
Roof 66.6 66.6 8.2 8.2 10.6 7.4 Fmin. = 0.2ISosWx
Fmax. = 0.4ISosWx
66.6 8.2
=
=
=
Ht.
(ft)
9
9
0.123
0.640 Max.
0,035 Min.
w
(kips)
40.3
21.6
4.7
66.6
Where:
Oxe allow. = 6a *I/Cd
(Section 12.8.6)
p : Redundancy Check
Required if story shear
is > 35% of base shear
(Section 12.3.4.2)
Wind Design
solidforms
eng i neeri ng
Page 5 of 7
01/24/24
Wind Pressures for MWFRS ASCE 7-16 -Envelope Procdedure Method 2
Design Variables
Occupancy=
l wind =
Basic Wind Speed (mph)=
Exposure category =
Topographic Kzt =
Width (ft)=
Length (ft) =
Roof Pitch
Eave Ht. (ft) =
Ridge Ht. (ft) =
Mean Roof Ht (ft) =
A=
9 =
AKztl =
2a (ft) =
Min. Design Load (psf) =
II
1.00
110
B
1
40.0
62.0
6: 12
9.0
19.0
14.0
1
26.6
1.0
11.2
16.0
Table 1.5-1
Tables 1.5-2
Figure 26.5-lA
Section 26. 7 .3
Section 26.8.2
Transverse
Longitudinal
Figure 28.6-1
Figure 28.6-1 Note 9
Section 28.4.4
Ps = AKztlp530 (28.6-1) Note: (-) Horiz. Pressures shall be zero.
Horiz. Press.
(psf) A B C D
Transverse 23.3 7.3 17.3 6.4
Longitudinal 19.2 -10.0 12.7 -5.9
Vertical --------------
Roaf angle I --------
-------------------7
1
-----Width, W •
-r Ridge
Eave height
height
I
Wind pressures are in psf
•Because wind presence is lass than zero (0), use O for design.
Transverse Governing Design Force:
Transverse Tributary Area:
Transverse Governing Design Pressure:
1 t t t t t t t t t + t t t t t t t t t t
Verticol
18.8 kips
1178 tt2
16.0 psf
Wind pressures are in psr
Longitudinal Governing Design Force:
Longitudinal Tributary Area:
Longitudinal Governing Design Pressure:
9.0 kips
560 tt2
16.0 psf
E
-6.8
-23.1
Vert. Press. Overhangs
F G H ECH GCH
-14.1 -5.1 -11.6 -16.0 -14.4
-13.1 -16.0 -10.1 -32.3 -25.3
Transverse
Zone Ps Area Force (k) Total (k)
A 23.3 101 2.4
B 7.3 112 0.8
C 17.3 457 7.9 14.4
D 6.4 508 3.272272
Min. 16.0 1178 18.8 18.8
E -6.8 224 -1.5
F -14.1 224 -3.2
G -5.1 1016 -5.2 -21.6
H -11.6 1016 -11.8
Min. -16.0 2480 -39.7 -39.7
Longitudinal
Zone P s Area Force (k) Total (k)
A 19.2 132 2.5
B
C 12.7 428 5.4 8.0
D
Min. 16.0 560 9.0 9.0
E -23.1 347 -8.0
F -13.1 347
G -16.0 893
-4.5
-14.3 -35.9
H -10.1 893 -9.0
Min. -16.0 2480 -39.7 -39.7
Lateral Design
Upper Level N-S Line:
Seis. Area (tt2) = 1160
Shear Line Len.Tot. (ft) = 4.5
Wind Relative to Ridge = Perpendicular
Wind Lengths:
41 = Vert.Trib Height (ft) =
Lw = Dist to Adj Gridline (ft) =
Shear Above: Line=
VxAtxr,,, (Seis/Wind) =
%Trib. of Load =
vxAbv.Trtb. (Seis/Wind) =
Wood Shearwalls =
Length =
Load Type =
Shear Load (lbs) =
Wall DLDlst. (psf) =
Resis. D~st. (plf) =
Resis. D½>oint (lbs) =
Dl.po1nt Dist (ft) =
MomentoT (lb-ft) =
IMomen~es1st. (lb-ft) =
Uplift (lbs) =
Upli~.,.,=
Upli~et. =
Left Holdown =
Right Holdown =
Seis. Area (tt2) =
Shear Line Len.Tot. (ft) =
Wind Relative to Ridge =
Wind Lengths:
41 = Vert.Trib Height (ft) =
lw = Dist to Adj Gridline (ft) =
Shear Above: Line =
VxAtme (Seis/Wind) =
%Trtb. of Load =
vxAbv.Tnb. (Seis/Wind) =
Left Right
I 10.0
I 40.0
-
--
W1
4.5
Seis. I Wind
1152 1920
16
10365 17280
712 875
2413 4101
2413 4101
Per Plan
Per Plan
Line:
Left Right
I
I
-
--
solidforms
enginee r ing
B Shearwall Seis. Wind
Strength Design Seis. Force: Fx = 2,8 psf
p = 1.0 Maximum Wind Pressure: Px = 16.0 psf
Sos= 0.797 Vxs.;s,(ASD) = Area/2*Fx*P*0.7 = 1152 lbs
Plate Ht. (ft) = 9 VxwirwJ = 41*Lw/2*Px *0.6 = 1920 lbs
Lwall Tot. (ft) = 4.5 'i.Vx (Above) = lbs
Vx Total = 1152 1920 lbs
--VJ L = 256 427 plf
----@ Use Shearwall Type=
with LTP4 clips @ 12 "o.c. 64%
W2
0 0 0
---
---
---
---
p = 1.0
Sos= 0.797
Plate Ht. (ft) =
Lwall Tot. (ft) =
-
---
for entire length of grid line B
W3 W4 Ws
I I I
0 0 0 0 0 0
------
------
------
------
Shearwall Seis. Wind
Strength Design Seis. Force: Fx =
-
Maximum Wind Pressure: Px =
VxSels.(ASD) = Area/2*Fx*P*0.7 =
xWind = LH*Lw/2*Px *0.6 = V
-
'i.Vx (Above) =
Vx Total =
VJL =
Use Shearwall Type=
with LTP4 clips@
for entire length of grid line
0
48 "o.c.
W5
I
psf
psf
lbs
lbs
lbs
lbs
plf
0
-
-
-
-
Page 6 of 7
01/24/24
Wood Shearwalls = I----W--=--1--+---W-=-2--+---W-=3--+---W_4'-------+---W_s'-------+---W--=--6 ----, Length =
Load Type = ,___ ...... l ______ __;___-+-_ ____.l __ +----"l'---+----.__l _-+----~l---1
Shear Load (lbs) =
Wall DLDlst. (psf) =
Resis. D~st (plf) =
Resis. D½>oint (lbs) =
D½>oint Dist (ft) = 1-----,----+---.------+----,----+----,----+---.----+----,---------'
MomentoT (lb-ft) =
I
Momen~es1st. (lb-ft) = l----+----+----+---+---l----+----+----+---+---1-----+---Uplift (lbs) =
Upli~ve=
Upli~et. =
Left Holdown =
Right Holdown =
'Resisting Moment DL is reduced by 0.6-0.14*5,,s for Seis.(12.14.3.1.3) & 0.6 for Wind (2.4.1)
solidforms
engi n ee r i ng
Redundancy Check
Removal of a shear wall or wall pier with a height-to-length ratio greater than 1.0 within any story, or
collector connections thereto, would not result in more than a 33% reduction in story strength. (ASCE
Table 12.3-3)
Upper Level
N-S
% Reduction of Story p Worst Case Force Removed (lbs) Story Strength (lbs) Strength
Gridline B 1152 5719 20% 1.0
Redundancy = 1.0
E-W
Worst Case Force Removed (lbs) Story Strength (lbs) % Reduction of Story p Strength
5719 0%
Redundancy = 1.0
Foundation Design
Concentrated Loads
Pad Ftg: F1 q= 1500 psf
Page 7 of 7
01/24/24
D( 2200 )+Lr( 2900 )+L( ) + W( ) + E( ) = 5,100 # Total Load
Gov. Load: D+Lr = 5100 # Factored Load
v(144* 5100 / 1500 )= 22.1 " Min. Square Dimension
Use: 24 "Sqr. x 12 " Deep with (3) #4 Bars Ea. Way Loaded:i:fH
Pad Ftg: F2 q= 1500 psf
D( 2700 )+Lr( 3000 )+L( ) + W( ) + E( ) = 5,700 # Total Load
Gov. Load: D+Lr = 5700 # Factored Load
v(l44* 5700 / 1500 )= 23.4 " Min. Square Dimension
Use: 27 "Sqr. x 12 " Deep with (3) #4 Bars Ea. Way Loaded:WfH