HomeMy WebLinkAboutAMEND 2021-0004; DISTRIBUTE LOTS 13-15 SHELL BUILDING; LETTER AMENDMENT - STORM WATER QUALITY MANAGEMENT PLAN (SWQMP); 2021-03-24A:COM March 24, 2021 City of Carlsbad Land Development Engineering 1635 Faraday Avenue Carlsbad, CA 92008 AECOM 300 Lakeside Dr., Ste. 400 Oakland, CA 94612 www.aecom.com 510 893 3600 tel 510 874 3268 fax Subject: Letter Amendment-Stonn Water Quality Management Plan (SWQMP), Permit No. GR2017-0004, Site Address 3266 Uonshead Avenue, Carlsbad, CA Attn: Land Development Engineering Department AECOM is pleased to provide the City of Carlsbad with this written correspondence regarding our review of the proposed improvements relative to the existing SWQMP for Permit No. GR2017-0004. Please note, given the insignificant nature of this change, this update or amendment is being provided mainly for purposes of record keeping so as to document that a very minor change was made to the parking lot but given the small relative decrease, no change to the amount of runoff for this area was recognized. The information below summarizes the background and conclusion associated with this change. Per the attached Figure 1, AECOM is to remove 27,692 s.f. of existing asphaltic pavement and replace it with a slightly lesser amount of 27,539 s.f. of proposed asphaltic pavement, resulting in a small net decrease to the impervious area of 153 s.f. for this localized area of the site. The location of the new asphalt is in the exact same location (see Figure 1) as it was previously defined in SWQMP Permit No. GR2017-0004. As a result of this very small relative change {Existing Area minus Proposed Area) of{-) 153 s.f. which equates to(-) 0.0035 acres reduction in area, it would potentially decrease the proposed amount of runoff for this area. However, given the small magnitude of this reduction in area, the associated runoff that would result is insignificant. With this in mind there is no change to the runoff amount that gets directed toward the bioretention facility located on the northwest side of the parking lot and therefore no change to the SWQMP will be required for Permit No. GR2017-0004. Sincerely, William Beaman Principal Civil Engineer "EXISTING 27,692 SF IMPERVlOUS SURFACE RUNOFF FLOWS TO THE EXISTING BtORETEl'ITION 8M.P SHOWN BELOW \ I IMPERVIOUS AREA TO 8E REMOVED • 27,692 SQ.FT -1 0l"'°'-ITI0'11 l.lOENC> r:.::J ftEMOYEPVMTJCONC. PRE-DEVELOPMENT CONDITIONS -PARKING LOT ii . ,o• ..., _, """"'""' ·PR0POSeo21,s39SF1MPERVK>us [ viou R 1 ... 0 2 [ CONITRUCTJONlEGENO SURFA.CERUNOFF'MLLFLCIWT0THE IMPER SA. EATO8E NSTA~ • 7,S39S0.FT. 1-------------J ~~~~~~~~s:~~E~~ ~ ~w cc»tCMTf -t£W PA.YEMEHJ *PROPOSED PARKING REDUCES IMPERVIOUS AREA BY 153 SQ.FT. -/-" -.. ··-. ·.·• ,· \ \ POST-DEVELOPMENT CONDITIONS -PARKING LOT .., . ... A:COM PROJECl OGB6 • Carlsbad, CA 3266 Uonshead Ave Carlsbad, CA 92010 AECOM 125$&-d.:91,~201 ailon, NJ 0701:S, USA 1736SJIIISOO •• ~~a~c ,,. -=----==~..;.:.,~':.:;:" ~..-..!l::l.:=:::-----····· i~==-=~~ ~i;:=-=-~~~~ ftEOISTRAllON ~SION ~·· 0 0 ....... l'TCiftlifMJERllOVRE .. .... ...,....,. PROJECT HUM8£R 1"41117 ~fflU! $WQCP AM£NOM£NTP:Oft CAALHAD IV,CEWAYLOTS 1Uf; H:AMIT MO, OR.2017~ SHOWIHO PflOflOSED tMf'Ellt'h:JUS LESS 'THAN l!lQ.S'nNG SHI.ITM.ltlll■U FIGURE 1