HomeMy WebLinkAbout2285 RUTHERFORD RD; ; CBC2024-0103; PermitBuilding Permit Finaled
(city of
Carlsbad
Commercial Permit
Print Date: 03/25/2025
Job Address: 2285 RUTHERFORD RD, CARLSBAD, CA 92008-8815
Permit Type: BLDG-Commercial Work Class:
Parcel#: 2120620800 Track#:
Valuation: $67,092.96 Lot#:
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition:
Sprinkled:
Project Title:
Project#:
Plan#:
Construction Type:
Orig. Plan Check#:
Plan Check#:
Description: QUIDELORTHO: 1,164 SF Tl; NO CHANGE IN USE
Applicant:
MCFARLANE ARCHITECTS
SARAH MCALLISTER
6256 GREENWICH DR, # STE 500
SAN DIEGO, CA 92122-5946
FEE
BUILDING PLAN CHECK
BUILDING PLAN REVIEW-MINOR PROJECTS (LOE)
BUILDING PLAN REVIEW -MINOR PROJECTS (PLN)
CERTIFICATE OF OCCUPANCY
COMM/IND Tl -STRUCTURAL
FIRE F Occupancies Tl
SB1473 -GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION -COMMERCIAL (SMIP)
Tenant Improvement
Permit No:
Status:
CBC2024-0103
Closed -Finaled
Applied: 04/12/2024
Issued: 05/28/2024
Finaled Close Out: 03/25/2025
Final Inspection: 11/18/2024
INSPECTOR: Kersch, Tim
Renfro, Chris
Contractor:
JIM LEEK BUILDERS INC
1687 LOTUS LN
EL CAJON, CA 92021-3716
{858) 735-8878
AMOUNT
$632.92
$197.00
$104.00
$20.00
$973.72
$791.00
$3.00
$18.79
Total Fees: $2,740.43 Total Payments To Date: $2,740.43 Balance Due: $0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
( City of
Carlsbad
COMMERCIAL
BUILDING PERMIT
APPLICATION
B-2
Plan Check ~e;G, ½!k:lf-O( Q3
Est. Value
PC Deposit
Date
Job Address 2285 RUTHERFORD ROAD Suite:. _____ APN: 212-062-08-00
Tenant Name #:._a_u_iD_E_L_o_R_T_Ho _____________ Lot #:. ____ Year Built: _1_98_2 ________ _
Year Built: 1982 Occupancy: B, F1, s1 Construction Type: Ill-A Fire sprinklers@'ESONO A/C:QYESONO
BRIEF DESCRIPTION OF WORK: INTERIOR Tl, INCLUDING MODIFICATIONS TO LAB AREAS ON FIRST & SECOND LEVELS OF EXISTINfl
PLUMBING FIXTURES, FREE STANDING HUDDLE ROOMS, FUME HOOD, ASSOCIATED STRUCTURAL & MEP.
D Addition/New: ____________ .New SF and Use, __________ New SF and Use
______ SF Deck, _______ SF Patio Cover, SF Other (Specify) ___ _
[{)Tenant Improvement: _1_,0_43 ___ SF,
LAB, WAREHOUSE, LAB. WAREHOUSE,
Existing Use: _FA_c_ro_R_v _____ Proposed Use: _F_Ac_rn_R_v ____ _
121 SF, Existing use: LAB. OFFICE. sroRAGE Proposed Use: LAB. OFFICE. STORAGE
D Pool/Spa: _____ .SF Additional Gas or Electrical Features? ____________ _
D Solar: ___ KW, ___ Modules, Mounted:ORoof OGround
D Reroof: _____________________________________ _
0 Plumbing/Mechanical/Electrical PLUMBING FIXTURES, ASSOCIATED MECHANICAL, ELECTRICAL, PLUMBING
I ✓ I Other: RECESSED CONCRETE SLAB FOR TENANT EQUIPMENT, FREE STANDING HUDDLE ROOMS.
APPLICANT (PRIMARY CONTACT) PROPERTY OWNER
Name· SARAH MCALLISTER / MCFARLANE ARCHITECTS Name: AREA-SD REGION NO. 71 , LLC, A DELAWARE LIMITED LIABILITY COMPANY
Address· 6256 GREENWICH DRIVE, STE 500 Address: 10996 TORREYANA ROAD, SUITE 250
City· SAN DIEGO State: CA Zip:_92_1_22 ___ City: SAN DIEGO State:_c_A __ .Zip: 92121
Phone· 858-453-1150 Phone: 858-638-2800
Email· sam@mcfarlaneachitects.com Email: ____________________ _
DESIGN PROFESSIONAL CONTRACTOR OF RECORD
Name· NEAL MCFARLANE / MCFARLANE ARCHITECTS Business Name: JIM LEEK BUILDERS
Address· 6256 GREENWICH DRIVE, STE 500 Address: 1687 LOTUS LANE
City· SAN DIEGO State: CA Zip:_9_21_2_2 ___ City: EL CAJON State:_C_A __ .Zip: 92021
Phone· 858-453-1150 Phone: 619-504-5295
Email· nkm@mctarlanearchitects.com Email: david.james.fontalne90@gmail.com
Architect State License: c-23691 CSLB License#: 612997 Class:._B ______ _
Carlsbad Business License# (Required):_2_86_3_1 _____ _
APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the
information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building
conStruction. SARAH MCALLISTER / MCFARLANE n 0~
NAME (PRINT): ARCHITECTS SIGN:~he M..,, ~ _j4 -,_ DATE:_04
_
10
_
9
_
120
_
2
_
4
___ _
1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Fax: 760-602-8558 Email: BuHding@caclsbadca.gov
REV. 07/21
THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: c&c:,ioz...<.f-0 l 03,
A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON
SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO
PERMIT ISSUANCE.
(OPTION A): LICENSED CONTRACTOR DECLARATION:
I herebyaffirmunderpenaltyof perjury that I am licensed under provisions of Chapter9 (commencing with Section 7000)of DMsionJ
of the Business and Prof esstons Code, and my license ts in full force and effect. I also affirm under penalty of perjury one of the
following declarations {CHOOSE ONE):
D1 have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit Is issued. PollcyNo. ____________________________________ _
-OR-6(11 have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit Is Issued.
My workers' compensation Insurance carrier and policy number are: Insurance Company Name: 5 f-t/t (wold (4}[Q11 {11.<tll' 4M" Ev.td
Polley No. '1 '-l I HS:S: -2o/ Expiration Date: '_,,__l_ .... _,l'---'2 .... c.._ _______ _
-OR-
Ocertlflcate of Exemption: I certify that In the performance of the work for which this permit Is Issued, I shall not employ any person In any manner so as to become
subject to the workers' compensation Laws of callfornla. WARNING: FaHure to secure workers compensation cove1111e ls unlawful and shall subject an employer to
criminal penalties and clvll fines up to $100,000.00, In addition the to the cost of compensation, dama1es as provided for In Section 3706 of the Labor Code,
Interest and attorney's fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there Is a construction lending agency for the performance of the work this permit is Issued (Sec. 3097 (I) Ovil Code).
Lender's Name: &/II Lender's Address: _,cAltL+b,:;,,~'-----------------
CONTRACTOR CERT/FICA TION: I certify that I have read the application and state that the above Information is correct and that
the Information on the plans is accurate. I agree to comply with all Cf ty ordinances and State laws relating to building
construction.
NAME (PRINT): !Javtd ffJHi a/1'1! SIGNATURE: ~ fdt> DATE: 'i Ir I I 2 'I
Note: If the person sl1nln1 above Is an authorized qent for the contractor provide a letter of authorization on contractor letterhead.
·OR·
(OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason: n I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure Is not intended or offered for sale (Sec. '-,d«, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or Improves thereon, and who does such
work himself or through his own employees, provided that such Improvements are not intended or offered for sale. If, however, the building or Improvement Is sold
within one year of completion, the owner-builder will have the burden of proving that he did not bu lid or improve for the purpose of sale).
-OR-
D1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor{s) licensed
pursuant to the Contractor's License law).
-OR-□, am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
AND, D FORM B-61 "Owner Builder Acknowled11ment and Verification Form" is required for any permit issued to a property owner.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
Improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if It has not been constructed in its entirety by licensed
contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, Is available upon request when this application Is
submitted or at the following Web site: http:Ilwww./eginfo.ca.gov/ ca/aw.html.
OWNER CERTIFICATION: I certify that I have read the application and state that the above information ts correct and that the
information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building
construction.
NAME (PRINT): SIGN: _________ DATE: _____ _
Note: If the person sl1nl111 above Is an authorized a1ent for the property owner Include form 8-62 sl1ned by property owner.
1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Fax: 760-602-8558 Email: Buildin1@carisbadca.gov
2 REV. 07/21
PERMIT INSPECTION HISTORY for (CBC2024-0103)
Application Date: 04/12/2024 Owner: Permit Type: BLDG-Commercial
Work Class: Tenant Improvement Issue Date: 05/28/2024 Subdivision: CARLSBAD TCT#81-10 UNIT#01
Status: Closed -Finaled Expiration Date: 03/10/2025
IVR Number: 55791
Address: 2285 RUTHERFORD RD
CARLSBAD, CA 92008-8815
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector Reinspection Inspection
BLDG-43 Air
Cond./Furnace Set
Checklist Item
260384-2024
COMMENTS
BLDG-Building Deficiency
09/18/2024 09/18/2024 BLDG-Final Inspection 261137-2024
Checklist Item COMMENTS
Status
Passed Tim Kersch
Partial Pass Tim Kersch
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Some rooms completed. Noted on card.
11/18/2024 11/18/2024 BLDG-Final Inspection 268201-2024 Passed Tim Kersch
Tuesday, March 25, 2025
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
Some rooms completed. Noted on card.
Complete
Passed
Yes
Relnspectlon Incomplete
Passed
Yes
No
Yes
No
No
Complete
Passed
Yes
Yes
Yes
Yes
Yes
Page 2 of 2
Building Permit Inspection History Finaled
{cityof
Carlsbad
PERMIT INSPECTION HISTORY for (CBC2024-0103)
Permit Type: BLDG-Commercial Application Date: 04/12/2024 Owner:
Work Class: Tenant Improvement Issue Date: 05/28/2024 Subdivision: CARLSBAD TCT#81-10 UNIT#01
Status: Closed -Finaled Expiration Date: 03/10/2025 Address: 2285 RUTHERFORD RD
IVR Number: 55791 CARLSBAD, CA 92008-8815
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
07/16/2024 07/16/2024 BLDG-17 Interior 254882-2024 Partial Pass Tim Kersch Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-21 254881-2024 Passed Tim Kersch Complete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-SW-Inspection 255027-2024 Passed Tim Kersch Complete
Checklist Item COMMENTS Passed
Are erosion control BMPs Yes
functioning properly?
Are perimeter control BMPs Yes
maintained?
Is the entrance stabilized to Yes
prevent tracking?
Have sediments been tracked Yes
on to the street?
Has trash/debris accumulated Yes
throughout the site?
Are portable restrooms Yes
properly positioned?
Do portable restrooms have Yes
secondary containment?
07/24/2024 07/24/2024 BLDG-11 255905-2024 Partial Pass Chris Renfro Reinspect ion Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial pass slab patch back. OK to pour. Yes
09/11/2024 09/11/2024 BLDG-24 Rough/Topout 260385-2024 Passed Tim Kersch Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-34 Rough 260383-2024 Passed Tim Kersch Complete
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Tuesday, March 25, 2025 Page 1 of 2
True North
COMPLIANCE SERVICES
May 15, 2024
City of Carlsbad
Community Development Department -Building Division
1635 Faraday Ave.
City of Carlsbad -FINAL REVIEW
City Permit No: CBC2024-0 I 03
True North No.: 24-0 I 8-299
Carlsbad, CA 92008
Plan Review: TI Quidelortho
Address: 2285 Rutherford Rd
Applicant Name: Sarah Mcallister / Mcfarlane Architects
Applicant Email: Sam@mcfarlanearchitects.com
OCCUPANCY AND BUILDING SUMMARY:
Occupancy Groups: B/F I /S-1
Occupant Load: 1,508
Type of Construction: IJI-A
Sprinklers: Yes
Stories: 2
Area of Work (sq. ft.): 1164 sq. ft.
The plans have been reviewed for coordination with the permit application.
Valuation: See Notes Below
Scope of Work: Confirmed
Floor Area: Confirmed
Notes: Valuation was not provided
Attn: Building & Safety Department,
True No1th Compliance Services, Inc. has completed the final review of the following documents for the project
referenced above on behalf of the C ity of Carlsbad:
I.
2.
Drawings: One (I) copy dated May 6, 2024, by Mcfarlane Architects.
Structural Calculations: One (I) copy, by kpff.
The 2022 California Building, Mechanical, Plumbing, and Electrical Codes (i.e., 2021 IBC, UMC, UPC, and 2020
NEC, as amended by the State of California), 2022 California Green Building Standards Code, 2022 California
Existing Building Code, and 2022 California Energy Code, as applicable, were used as the basis of our review.
Please note that our review has been completed and we have no further comments, however, we bring the
following to your attention:
I. In order to expedite the permitting process, we have made annotations (in red ink) to Coversheet.
True North Compliance Services, Inc.
8369 Vickers Street, Suite 207, San Diego, CA 92111
T / 562.733.8030
We have enclosed the above noted documents bearing our review stamps for your use. Please call if you have any
questions or ifwe can be of further assistance.
Sincerely,
True North Compliance Services
Review By: Mohammad Afaneh -Plan Review Engineer
Quality Review By: Alaa Atassi -Plan Review Engineer
3131 Camino Del Rio North. Suite 1080 San Diego, CA 92108 619.5?1.8500 kpff com
CBC2024-0103
Quidel
Project Redwood
Structural Calculations
KPFF Project #2400030
2285 RUTHERFORD RD
QUIDELORTHO : IN Tl OF 1,164 INCLUDING PLUMBING.
MECHANICAL AND ELECTRICAL
2120620800
5/6/2024
CBC2024-0103
Calculation Index
Job: Quidel Project Redwood KPFFJob No 2400030
Address: 2285 Rutherford Road
(These calculations apply to the job at this address only)
Revision No. 1
Item: Sheet:
Clean Room Design Al -A27
Mechanical Anchorage Bl -822
Index page 1 of 1
3131 Camino Del Rio North. Suite 1080 San Diego, CA 92108 619.521.8500 kpff.corn
Quidel
Project Redwood
Clean Rooms
A1
3131 Camino Del Rio North, Suite 1080 San Diego, CA 92108 619.521.8500 kpff.com
Quidel
Project Redwood
Clean Room
Design Criteria
3131 Camino Del Rio N
Suite 1080
proiect Quidel Project Redwood
San Diego, CA 92108
p (619) 521-8500
f (619) 521-8591
www.kpff.com
Design Criteria
Use 80/20 extruded aluminum
location
client
Cue Clean Room
Ceiling weight = 1 psf + self weight of framing
Max live load = 300 lb at any location
Clean room is installed inside existing warehouse = 5psf Wind Load
Seismic Criteria
Use ASCE 7-16 Chapter 12.8
V=CsW
Cs= Sds/(R/le)
Sds = 0.774, see design criteria
R = 1.25
Omega= 2.0
le= 1.0
!cs= 0.619 <-Governs I
Csmin = 0.44Sdsle = 0.044 x 0.774 x 1.0 = .0341 < 0.619-> OK
Ceiling Deflection Criteria = D+L <= U120
Date
Design Code Reference Document
Risk Category
Site Class
Type Value Description
Ss 0.968 MCER ground motion. (for 0.2 second period)
S1 0.354 MCER ground motion. (for 1.0s period)
SMs 1.161 Site-modified spectral acceleration value
SM1 0.531 Site-modified spectral acceleration value
Sos 0.774 Numeric seismic design value at 0.2 second SA
So1 0.354 Numeric seismic design value at 1.0 second SA
4/26/2024, 9:39:00 AM
ASCE7-16
II
C -Very Dense Soil and Soft Rock
bv MS ~2 sheet no.
date 03/08/24
job no. 2400033
A3
3131 Camino Del Rio North. Suite 1080 San Diego, CA 92108 619.521.8500 kpff.com
Quide/
Project Redwood
Clean Room
Gravity and Lateral Design
Av
IIIRISA 1:~:ok I
2000409 A,N(','f'f~t ,..,.,,
Cue Vista Clean Room
All member properties
were defined in RISA
to perform analysis.
SK-1
A4
Section Sets ..
■ 40-8080-LITE
Mar 13, 2024 at 04:44 PM
Clean Room.r3d
Company , :
Designer
Job Number:
Section Properties: 40-8080-LITE
Section Information:
Material Type = General
Shape Type = Arbitrary
Number of Shapes = 1
Basic Properties:
Total Width = 3.150 in
Total Height = 3.150 in
Centroid, Xo = -0.000 in
Centroid, Yo = -0.000 in I i
X-Bar (Right) = 1.575 in
X-Bar {Left) = 1.575 in
Y-Bar (Top) = 1.575 in ;
Y-Bar (Bot) = 1.575 in
Max Thick = 3.150 in ·~+
Equivalent Properties:
Area, Ax = 3.142 in"2
Inertia, lxx = 3.311 in"4
Inertia, lyy = 3.311 in"4
Inertia, lxy = -0.000 in"4
Sx (Top) = 2.102 in"3
Sx (Bot) = 2.102 in"3
Sy (Left) = 2.102 in"3
Sy (Right) = 2.102 in"3 Section Diagram
rx = 1.026 in
ry = 1.026 in
Plastic Zx = 2.942 in"3
Plastic Zy = 2.942 in"3
Torsional J = 2.051 in"4
As-xx Def = 1.000
As-yy Def = 1.000
As-xx Stress = 1.000
As-yy Stress = 1.000
C:\RISA User Data\msnook\RISASection Files\80-20 Sections.nmsx
v,
un
AS
Mar 26, 2024
15:06 PM
Checked By: __
-------
--·x
Page 1
A6
x-0 y
1 psf DL at ceiling and
walls.
Loads: BLC 1, DL
IIIRIS~ I :::ok I
2000409 "-E'-En ..... .., ..
Cue Vista Clean Room SK-2
Mar 13, 2024 at 04:45 PM
Clean Room.r3d
xlih y
Loads: BLC 3, Ex
IIIRIS~ 1:~:ok I
2000409 ..,.-,..-r• I(, "IM'.,.~,
Cue Vista Clean Room
1 psf + self weight
applied in X direction,
forces scaled in load
combinations
SK-3
Mar 13, 2024 at 04:45 PM
Clean Room.r3d
A7
x-® y
Loads: BLC 4, Ey -1 psf
IIIRIS~ 1::~:ok I
2000409 &."fE\lf'TS 1MP11i..,.
Cue Vista Clean Room
1 psf+ self weight
applied in Y direction,
forces scaled in load
combinations
SK-4
Mar 13, 2024 at 04:46 PM
Clean Room.r3d
AB
x-® y
Loads: BLC 5, Windy
II . I KPFF I IRIS~ msnook
2000409 A!ifMF.n ~"I'
Cue Vista Clean Room
5psf wind load,
Y-direction
A9
SK-5
Mar 13, 2024 at 04:46 PM
Clean Room.r3d
x-0 y
Loads: BLC 6, Windx
II . I KPFF I IRIS~ msnook
2000409 Ai"'ltW,TS;I,
Cue Vista Clean Room
5psf wind load,
X-direction
SK-6
Mar 13, 2024 at 04:46 PM
Clean Room.r3d
A10
ll1R1sA
A N(METSCHEK COMPANY
Load Combinations
Company : KPFF
Designer : msnook
Job Number : 2000409
Model Name : Cue Vista Clean Room
A11
3/13/2024
4:54:27 PM
Checked By : ___ _
Description Solve BLC Factor BLC Factor BLC Factor BLC Factor
1 DL
2 LL
3 DL + LL
4 1.4DL
5 1.2DL + 1.6LL
6 1.0DL + 0.7EX +0.21EY
7 1.0DL + 0.7EY + 0.21EX
8 1.0DL + 0.7EX -0.21EY
9 1.0DL + 0.7EY-0.21EX
10 1.0DL + 0.75/0.7EX) + 0.75/0.21EY) + 0.75LL
11 1.0DL + 0.75/0.7EY) + 0.75I0.21EX\ + 0.75LL
12 1.0DL + 0.75/0.7EX) -0.75/0.21 EY) + 0.75LL
13 1.0DL + 0.75/0.7EY) -0.7510.21 EX)+ 0.75LL
14 0.6DL + 0.7EX +0.21EY
15 0.6DL + 0.7EY + 0.21EX
16 0.6DL + 0.7EX -0.21 EY
17 0.6DL + 0.7EY -0.21 EX
18 Omeaa Combinations
19 1.2DL + 2.0/1.0EX) + 2.0/0.3EY) + 0.5LL
20 1.2DL + 2.0I1 .0EY) + 2.0/0.3EX) + 0.5LL
21 1.2DL + 2.0I1 .0EX\ -2.0I0.3EY\ + 0.5LL
22 1.2DL + 2.0/1 .0EZ) -2.0/0.3EX) + 0.5LL
23 0.9DL + 2.0<1 .0EX\ + 2.0f0.3EY\
24 0.9DL + 2.0/1 .0EY) + 2.0/0.3EX)
25 0.9DL + 2.0<1.0EX\ -2.0f0.3EY\
26 0.9DL + 2.0(1 .0EY) -2.0/0.3EX)
27 Wind Combinations
28 1.0DL + 0.6Wx
29 1.0DL + 0.6Wv
30 1.0DL -0.6Wx
31 1.0DL -0.6Wv
32 1.0DL + 0.45Wx + 0. 75LL
33 1.0DL + 0.45Wv + 0.75LL
34 1.0DL -0.45Wx + 0.75LL
35 1.0DL -0.45Wv + 0.75LL
36 0.6DL + 0.6Wx
37 0.6DL + 0.6Wv
38 0.6DL -0.6Wx
39 0.6DL -0.6Wv
40 self
Cs= 0.619
Omega= 2.0
Yes DL 1
Yes LL 1
Yes DL 1
Yes DL 1.4
Yes DL 1.2
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 0.6
Yes DL 0.6
Yes DL 0.6
Yes DL 0.6
DL 1.2
DL 1.2
DL 1.2
DL 1.2
DL 0.9
DL 0.9
DL 0.9
DL 0.9
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 0.6
Yes DL 0.6
Yes DL 0.6
Yes DL 0.6
OL2 1
Factors were pre-multiplied and inserted into combination
Ex: LC 6
LL 1
LL 1.6
ELX 0.433
ELY 0.433
ELX 0.433
ELY 0.433
ELX 0.325
ELY 0.325
ELX 0.325
ELY 0.325
ELX 0.433
ELY 0.433
ELX 0.433
ELY 0.433
O*ELX 1.238
O*ELY 1.238
O*ELX 1.238
O*ELY 1.238
O*ELX 1.238
O*ELY 1.238
O*ELX 1.238
O*ELY 1.238
WLX 0.6
WLY 0.6
WLX -0.6
WLY -0.6
WLX 0.45
WLY 0.45
WLX -0.45
WLY -0.45
WLX 0.6
WLY 0.6
WLX -0.6
WLY -0.6
1.0DL + 0.7(0.619Ex) + 0.21 (0.619Ez) = 1.0DL + 0.433Ex + 0.13Ez
RISA-3D Version 22 [ Clean Room.r3d ]
LLS 1.6
ELY 0.13
ELX 0.13
ELY -0.13
ELX -0.13
ELY 0.097 LL 0.75
ELX 0.097 LL 0.75
ELY -0.097 LL 0.75
ELX -0.097 LL 0.75
ELY 0.13
ELX 0.13
ELY -0.13
ELX -0.13
O*ELY 0.371 LL 0.5
O*ELX 0.371 LL 0.5
O*ELY -0.371 LL 0.5
O*ELX -0.371 LL 0.5
O*ELY 0.371
O*ELX 0.371
O*ELY -0.371
O*ELX -0.371
LL 0.75
LL 0.75
LL 0.75
LL 0.75
Page 1
IIIRISA
Company : KPFF
Designer : msnook
Job Number : 2000409
ANEMETSCHE1<co.iPANv Model Name Cue Vista Clean Room
Enveto.2.e Maximum Member Section Forces
3/13/2024
4:47:34 PM
A12
Checked By : ___ _
Member Axialflbl Locfinl LC v Shear[lb Loc[inl LC z Shear[lb Locfin LC Torauellb-ft Locfin LC v-v Momentrlb-ft Locfin LC z-z Momentflb-ft Locfin LC
1 M1 max 115.235 151 9 305.165 0 31 85.207 0 30 2.908 151 30 357.964 75.5 30 1463.478 0 31
2 min -44.241 0 15 -305.165 151 29 -85.207 0 36 -2.908 0 36 -357.964 75.5 36 -1124.64 151 39
3 M2 max 23.323 151 17 85.143 0 4 22.544 151 8 0.205 151 37 21 .277 75.5 17 0 151 39
4 min -23.991 0 7 -85.143 151 4 -22.544 0 6 -0.205 0 31 -70.919 75.5 6 -267.844 75.5 4
5 M3 max 29.979 151 9 481.922 0 31 22.569 151 6 1.373 151 30 40.994 151 6 2724.398 0 31
6 min -18.067 0 15 -481 .922 151 29 -22.569 0 8 -1.373 75.5 36 -30.085 75.5 8 -2604.498 151 39
7 M4 max 23.269 151 15 85.143 0 4 22.544 151 8 0.204 151 31 21 .277 75.5 9 0 151 39
8 min -24.081 0 9 -85.143 151 4 -22.544 0 8 -0.204 75.5 37 -70.919 75.5 8 -267.844 75.5 4
9 M5 max 148.521 151 7 361.821 0 31 174.018 151 28 2.89 50.333 30 703.461 80.219 30 1561.072 151 29
10 min -85 0 17 -361.822 151 29 -174.018 151 30 -2.89 0 36 -703.461 80.219 36 -1115.894 0 37
11 M6 max 173.396 72 30 27.998 0 4 27 0 39 57.776 72 31 40.5 36 39 0 72 39
12 min -173.396 0 36 -27.998 72 4 -27 0 29 -56.605 0 37 -40.5 36 29 -41 .997 36 4
13 M7 max 301.221 72 28 383.167 0 6 112.757 0 31 50.616 72 37 491.583 0 37 2178.979 0 6
14 min -301 .221 0 38 -220.578 72 38 -112.748 0 37 -64.37 0 31 -491 .632 0 31 -1251.469 0 38
15 MB max 172.772 72 38 27.998 0 4 27 0 39 56.605 72 39 40.5 36 39 0 72 39
16 min -172.772 0 28 -27.998 72 4 -27 0 29 -57.776 0 29 -40.5 36 29 -41.997 36 4
17 M9 max 313.065 72 36 383.167 0 8 112.748 0 39 64.37 72 29 491.632 0 29 2178.975 0 8
18 min -313.065 0 30 -224.688 72 38 -112.757 0 29 -50.616 0 39 -491.583 0 39 -1276.136 0 38
19 M10 max 63.183 0 6 235.616 0 6 93.907 0 31 222.797 144 39 401.442 72 31 515.599 72 38
20 min -63.183 144 6 -235.616 144 6 -93.577 0 37 -229.093 72 29 -399.462 72 37 -1293.705 72 6
21 M11 max 63.181 0 6 230.267 0 30 93.882 144 37 243.044 72 37 403.709 72 31 547.034 72 16
22 min -63.181 144 6 -230.267 144 30 -94.285 144 31 -245.388 72 31 -401.293 72 37 -1261 .609 72 30
23 M12 max 63.183 0 8 235.616 0 8 93.577 0 39 229.093 72 31 399.462 72 39 503.268 72 38
24 min -63.183 144 8 -235.616 144 8 -93.907 0 29 -222.797 72 37 -401.442 72 29 -1293.707 72 8
25 M13 max 63.181 0 8 228.211 0 30 94.285 144 29 245.388 72 29 401.293 72 39 547.036 72 14
26 min -63.181 144 8 -228.211 144 30 -93.882 144 39 -243.044 0 39 -403.709 72 29 -1249.279 72 30
27 M14 max 475.219 0 29 108.427 144 39 126.756 72 36 0 144 39 760.536 72 36 1496.702 144 29
28 min -97.139 144 39 -171 .874 72 29 -126.756 0 30 0 0 1 -760.536 72 30 -1065.278 144 39
29 M15 max 475.217 0 31 171 .874 144 31 125.626 72 28 0 144 39 753.756 72 28 1065.278 144 37
30 min -97.14 144 37 -108.427 72 37 -125.626 0 38 0 0 1 -753.756 72 38 -1496.702 144 31
31 M16 max 339.259 72 8 40.598 0 4 54 72 39 67.22 72 31 81 36 37 0 72 39
32 min -293.165 0 38 -40.598 72 4 -54 72 29 -65.084 0 37 -81 36 31 -60.897 36 4
33 M17 max 174.62 72 8 40.598 0 4 54 72 39 319.331 72 39 81 36 37 0 72 39
34 min -118.048 0 38 -40.598 72 4 -54 72 29 -325.121 0 29 -81 36 31 -60.897 36 4
35 M18 max 391 .239 144 8 75.714 144 29 98.968 144 8 24.602 144 31 525.349 72 38 454.285 72 29
36 min -252.948 0 38 -75.054 72 39 -98.968 0 8 -24.6 72 37 -576.11 72 8 -450.322 72 39
37 M19 max 376.429 144 30 76.752 144 29 98.963 144 8 22.905 144 37 525.204 72 38 460.514 72 29
38 min -267.538 0 14 -75.947 72 39 -98.963 0 8 -22.908 0 31 -576.08 72 8 -455.68 72 39
39 M20 max 137.519 72 38 40.598 0 4 54 0 29 339.9 72 29 81 36 29 0 72 39
40 min -178.302 0 8 -40.598 72 4 -54 0 39 -332.282 0 39 -81 36 39 -60.897 36 4
RISA-3D Version 22 [ Clean Room.r3d ] Page 1
IIIRISA
Company : KPFF
Designer : msnook
Job Number : 2000409
A NEMETSCHf)c, COMPANY Model Name : Cue Vista Clean Room
~Envelope Maximum Member Section Forces (Continued)
Member Axialllbl Loclinl LC v Shearnb Loc[in] LC z Shearnb Locfin LC Toraueflb-ft
41 M21 max 312.587 72 38 40.598 0 4 54 0 37 67.385
42 min -342.93 0 8 -40.598 72 4 -54 0 31 -69.435
43 M22 max 391.238 144 6 75.054 144 37 98.968 144 6 24.6
44 min -257.059 0 38 -75.714 72 31 -98.968 0 6 -24.602
45 M23 max 380.54 144 30 75.947 144 37 98.963 144 6 22.908
46 min -267.537 0 16 -76.752 72 31 -98.963 0 6 -22.905
47 M24 max 174.62 0 6 40.598 0 4 54 0 39 325.121
48 min -121.287 0 30 -40.598 72 4 -54 0 29 -319.331
49 M25 max 339.258 0 6 40.598 0 4 54 0 39 65.084
50 min -299.205 0 30 -40.598 72 4 -54 0 29 -67.22
51 M26 max 316.735 72 30 40.598 0 4 54 72 29 69.435
52 min -342.929 72 6 -40.598 72 4 -54 72 39 -67.385
53 M27 max 138.87 72 30 40.598 0 4 54 72 37 332.282
54 min -178.302 72 6 -40.598 72 4 -54 72 31 -339.9
55 M28 max 428.564 144 31 68.415 72 37 98.758 144 8 0
56 min -123.216 0 37 -139.361 0 31 -98.935 0 6 0
57 M29 max 428.564 144 29 139.361 72 29 98.757 144 6 0
58 min -123.216 0 39 -68.415 0 39 -98.935 0 8 0
59 M30 max 797.922 144 29 341.896 144 29 595.351 72 6 0
60 min -255.011 0 39 -329.982 72 39 -573.203 0 30 0
61 M31 max 797.922 144 31 329.982 144 37 595.352 72 8 0
62 min -255.011 0 37 -341 .896 72 31 -563.768 0 38 0
63 M32 max 68.02 75.5 31 68.52 0 4 85.207 151 36 3.792
64 min -68.02 77.073 31 -68.52 151 4 -85.207 151 30 -3.792
65 M33 max 19.606 144 4 136.04 70.5 31 56.625 72 30 3.395
66 min -1 27.128 0 4 -136.04 72 31 -56.625 0 36 -3.395
67 M34 max 103.904 75.5 37 42.571 0 4 56.625 0 38 3.524
68 min -189.6 0 31 -42.571 75.5 4 -56.625 0 28 -3.524
69 M35 max 103.904 75.5 39 42.571 0 4 56.625 75.5 36 3.529
70 min -189.6 0 29 -42.571 75.5 4 -56.625 75.5 30 -3.529
71 M36 max 0 144.002 2 122.032 0 29 57.081 72.001 28 2.116
72 min -1 09.864 0 4 -122.032 144.002 29 -57.081 0 30 -2.116
73 M37 max 0 144.002 2 122.032 0 31 57.107 72.001 38 2.117
74 min -109.857 0 4 -122.032 144.002 31 -57.107 0 28 -2.117
75 M38 max 122.099 51 29 19.823 0 4 19.107 0 36 0
76 min -95.092 0 39 -19.811 51 4 -19.107 0 30 0
77 M39 max 122.099 51 31 19.804 0 4 19.107 0 36 0
78 min -95.092 0 37 -19.831 51 4 -19.107 0 30 0
79 M40 max 190.441 50.667 39 28.569 0 4 38 0 36 456.979
80 min -243.769 0 29 -28.569 50.667 4 -38 0 30 -456.979
81 M41 max 190.441 50.667 37 28.569 0 4 38 0 36 457.291
RISA-3D Version 22 [ Clean Room.r3d ]
Loclin LC v-v Moment[lb-ft Loclin
72 37 81 36
0 31 -81 36
144 39 533.753 72
0 29 -576.108 72
144 29 533.596 72
0 39 -576.078 72
72 31 81 36
0 37 -81 36
72 39 81 36
0 29 -81 36
72 29 81 36
0 39 -81 36
72 37 81 36
0 31 -81 36
144 39 526.223 72
0 1 -575.928 72
144 39 535.06 72
0 1 -575.927 72
144 39 3182.79 0
0 1 -3309.072 0
144 39 3130.71 0
0 1 -3309.08 0
75.5 30 357.962 75.5
0 36 -357.962 75.5
144 36 339.752 72
0 30 -339.752 72
75.5 30 89.066 37.75
0 36 -89.066 37.75
75.5 30 89.066 37.75
0 36 -89.066 37.75
72.001 36 342.488 172.001
0 30 -342.488 72.001
72.001 38 342.644 172.001
0 28 -342.644 72.001
51 39 20.309 25.5
0 1 -20.309 25.5
51 39 20.309 25.5
0 1 -20.309 25.5
~0.667 38 45.682 ~5.333
0 28 -45.682 ~5.333
50.667 28 45.682 ?5.333
3/13/2024
4:47:34 PM
A13
Checked By : ___ _
LC z-z Momentllb-ft Loclin LC
37 0 72 39
31 -60.897 36 4
30 450.322 72 37
6 -454.285 72 31
30 455.68 72 37
6 -460.514 72 31
39 0 72 39
29 -60.897 36 4
39 0 72 39
29 -60.897 36 4
31 0 72 39
37 -60.897 36 4
39 0 72 39
29 -60.897 36 4
38 1068.035 0 37
8 -1405.702 0 31
30 1405.702 0 29
6 -1068.035 0 39
30 2846.543 0 29
6 -2711 .718 0 39
38 2711.718 0 37
8 -2846.544 0 31
30 0 151 39
36 -246.393 75.5 4
30 816.239 72 37
36 -816.239 72 31
38 0 75.5 39
28 -66.961 37.75 4
38 0 75.5 39
28 -66.961 37.75 4
28 570.969 72.001 39
30 -731 .897 72.001 29
38 570.969 '2.001 37
28 -731 .897 2.001 31
36 0 51 39
30 -21 .066 25.5 4
36 0 51 39
30 -21.079 25.5 4
36 0 0.667 39
30 -32.756 5.333 4
36 0 0.667 39
Page 2
IIIRISA
Company : KPFF
Designer : msnook
Job Number : 2000409
A '<EMETSCHEK co«PANv Model Name : Cue Vista Clean Room
Envelope Maximum Member Section Forces (Continued)
Member Axialllbl Locfinl LC v Shear[lb Loc[in] LC z Shear[lb Loc[in LC Toraueflb-ft
82 min -243.769 0 31 -28.569 50.667 4 -38 0 30 -457.291
83 M42 max 260.954 72 38 235.196 0 16 113.695 72 37 57.776
84 min -278.878 72 8 -368.387 72 30 -113.704 72 31 -56.605
85 M43 max 213.687 72 28 27.998 0 4 27 72 37 50.616
86 min -213.687 0 38 -27.998 72 4 -27 72 31 -64.37
87 M44 max 261.731 72 30 235.195 0 14 113.704 72 29 56.605
88 min -278.878 72 6 -372.497 72 30 -113.695 72 39 -57.776
89 M45 max 224.132 72 36 27.998 0 4 27 72 37 64.37
90 min -224.132 0 30 -27.998 72 4 -27 72 31 -50.616
RISA-3D Version 22 [ Clean Room.r3d ]
Locfin LC v-v Moment[lb-ft Loc[in
0 30 -45.682 ~5.333
72 31 495.572 72
0 37 -495.622 72
72 37 40.5 36
0 31 -40.5 36
72 39 495.622 72
0 29 -495.572 72
72 29 40.5 36
0 39 -40.5 36
3113/2024
4:47:34 PM
A14
Checked By : ___ _
LC z-z Momentrlb-ft Locfin LC
30 -32.756 ~5.333 4
37 2090.329 72 30
31 -1339.149 72 16
39 0 72 39
29 -41 .997 36 4
29 2114.996 72 30
39 -1339.145 72 14
39 0 72 39
29 -41.997 36 4
Page 3
ro·ect b
A 15 sheet no.
l<Rff 3131 Camino Del Rio N
Suit e 1080
San Diego, CA 92108 location date
p (619) 521-8500
f (619) 521-8591 client job no.
I ' w ww.kpff.com
I 10 check the individual elements for local I bucking
Element 1 ~ Element 2
b(ln) 0.5 b(ln) 0.75
tlln) 0.1299 tllnl 0.1299
Efk$1l 10153 Efksll 10153
Fcv (k$1l 35 Fcv fbll 35
Ae 21.80 Ae 21.80
Al 33.46 Al 33.46
ds fin) 0.25 ds llnl 0.25
8 90 8 90
rs 0.14 rs 0.14
pST 1.00 pST 1.00
Element 1 Element 2
Element Stress Element Support Fe Aeq Element Stress Element Support Fe
Flat Sun=rted on Both Ed•es 2642.00 6.2 Flat Sun=rted on Both Ed•es 1174.22
Flat Sunnorted on One Ed•e 270.54 19.2 Flat Sun=rted on One Ed•e 120.24
Flat Supported on one edge with a 2642.00 6.2 siffener on the other edge Fial Supported on one edge with a 272.37 siffener on the other edge
Elastic buckling stress of elements for compression was checked per
Aluminum Design Manual and it was found that it was not the governing
facto r since the element lengths are small. Local bucking of elements is not
an issue for these members.
Table B.5.1
ELASTIC BUCKLING STRESS F. OF ELEMENTS
Elo,,,.,,tlype Element Streu Elam1n1 Suppo,t
Ital unllo<m co,np,uslon 1'4)p0(1ed on bOth eao,,,
unilo<m comp..ulon supported on one eclge
flat uni1orm compression •-""' on bOth adges 1111d wnh an ln1etmoara1e sollene<
unilorm _.,.,ion s-18<1 on bOth eao,,s
Note: > .. Is determined from equallon B.5-10
F,
rrE
(1.6blr)'
b
., . ., ............... .
Aeq
9.2
28.9
19.2
oroject Quidel bv MS ~ 16 sheet no.
llP,ff 3131 Camino Del Rio N
Suite 1080 location San Diego date 3/13/24 San Diego, CA 92108
p (619) 521-8500
job no. 2400030 f (619) 521-8591 client
E ,q, r www.kpff.com
E (ksi) 10200 Be 39.36527 De 0.244551 Cc 65.99748
Fey (ksi) 35 Bp 45.00139 Op 0.298909 Cp 61.72641
Bbr 66.82428 Dbr 0.662441 Cbr 67.25058
Table B.4.2
BUCKLING CONSTANTS FOR TEMPER DESIGNATIONS
BEGINNING WITH TS, T6, T7, TS, OR T9
Type of Stress and Member Intercept Slope Intersection
Compression in Columns and Beam Flanges 8,=F.,(1 +(~r) D = 8,(~),,.
• 10 E
C, = 0.41 8• D,
Axial Compression in Flat Elements 8, = F.,(1 + (~r) D .. ~(~)"' • 10 E
c ... o.41 ~ o.
Axial Compression in Curved Elements 8,= F.,(1 +(~)'•) D,= ~(~)"' C, see note 2 50,000,c 4.5 E
Bending Compression In Flat Elements 8., = 1.3F.,(1 + (t~r) D., = 8., (68.,)'" C.,=28,.
20 E 30.,
Bending Compression in Curved Elements 8,. = 1.5F.,( 1 + (so.~icr) o,. = 8., (8.,)""
2.7 E
c., = (8., -8,)' o,,, o,
Shear In Flat Elements 8,=F•(1 •(~r) D, = 8, (~)•12 C,a0.41 8•
10 E D,
Notes
1 • • IO ksi (6 895 MPa)
2 C, shall be delerm,ned using a plol ol cur-of hmll stale stress based on elastic and Inelastic bucld,ng or by trial and error solul,on.
40-8080-LITE
Table 8.4.3 L (in) 90
POSTBUCKLING CONSTANTS K 2
r(in) 1.03
Type of Element I<, Ir, Al 17.85
Flat Elements in Compression for Temper 0.50 2.04
Designations Beginning with 0, H, T1 , A.2 66.00
T2, T3, or T4. and weld-affected zones A 175.44 of all tempers
A(in2) Flat Elements in Compression for Temper 0.35 2.27 3.142 Designations Beginning with TS, T6,
T7. TS, orT9
Flat Elements in Flexure 0.50 2.04 Fe 2.780152
<l>Pc 7.861714
Axial Capacity is Based on Global Buckling of Members
Using the Aluminum Design Code ADM Section B.5
A17
From Manuf
Member Properties V My Mz Axial Strength
[Shape Area ly lz dy dz Omega Fy (ksi) I (k) {lb) (k") (lb') (k") (lb') (lb) __
140-8080-LITE 3.142 3.311 3.311 1.575 1.575 2.051 1.65 35 I 66.65 66648 44.59 3716 44.59 3716 7861.71
Shear Capacity:
V = (Area*Fy)/Omega = 66.65k
Moment Capacity:
My= Mz = (Fy*(ly/dy))/Omega = 44.59k"
Axial Strength:
See previous pages
A18
Summary Of Member Forces
Axial (lb) Y Shear (lb) Z Shear (lb) Torque (lb') Y Moment (lb') Z Moment (lb')
Ml max 115.24 305.17 85.21 2.91 357.96 1463.48
40-8080-LITE min 44.24 305.17 85.21 2.91 357.96 1124.64
M2 max 23.32 85.14 22.54 0.21 21.28 0.00
40-8080-LITE min 23.99 85.14 22.54 0.21 70.92 267.84
M3 max 29.98 481.92 22.57 1.37 40.99 2724.40
40-8080-LITE min 18.07 481.92 22.57 1.37 30.09 2604.50
M4 max 23.27 85.14 22.54 0.20 21.28 0.00
40-8080-LITE min 24.08 85.14 22.54 0.20 70.92 267.84
•. ,.,.,.c·in.z·,.,,,., -, .. ,., ·o,og: ·./.L_._l()_)::;._, • • •.•· ,13.3'L ,-,. ·-,-, .. 03a • .l j].ii,() ,.;-,,. ifoi :9-~P. /:,i%:tiif'? • ( ;~•-•·
•,.,-,,:;-:-o.n: ,, ....... :.,.::,t .. o:ai . .,., .·-·,its?. ....... · ··---•o-oo· o.3o . , .. ;:;:o:if\/ ?l):~r < \ii'.~£/.)•-••,, .i1~{: >· <~Ji
MS max 148.52 361.82 174.02 2.89 703.46 1561.07
40-8080-LITE min 85.00 361.82 174.02 2.89 703.46 1115.89
M6 max 173.40 28.00 27.00 57.78 40.50 0.00
40-8080-LITE min 173.40 28.00 27.00 56.61 40.50 42.00
M7 max 301.22 383.17 112.76 50.62 491.58 2178.98
40-8080-LITE min 301.22 220.58 112.75 64.37 491.63 1251.47
MB max 172.77 28.00 27.00 56.61 40.50 0.00
40-8080•LITE min 172.77 28.00 27.00 57.78 40.50 42.00
M9 max 313.07 383.17 112.75 64.37 491.63 2178.98
40-8080-LITE min 313.07 224.69 112.76 50.62 491.58 1276.14
MlO max 63.18 235.62 93.91 222.80 401.44 515.60
40-8080-LITE min 63.18 235.62 93.58 229.09 399.46 1293.71
Mll max 63.18 230.27 93.88 243.04 403.71 547.03
40-8080-LITE min 63.18 230.27 94.29 245.39 401.29 1261.61
M12 max 63.18 235.62 93.58 229.09 399.46 503.27
40-8080-LITE min 63.18 235.62 93.91 222.80 401.44 1293.71
Ml3 max 63.18 228.21 94.29 245.39 401.29 547.04
40-8080-LITE min 63.18 228.21 93.88 243.04 403.71 1249.28
M14 max 475.22 108.43 126.76 0.00 760.54 1496.70
40-8080-LITE min 97.14 171.87 126.76 0.00 760.54 1065.28
MlS max 475.22 171.87 125.63 0.00 753.76 1065.28
40-8080-LITE min 97.14 108.43 125.63 0.00 753.76 1496.70
M16 max 339.26 40.60 54.00 67.22 81.00 0.00
40-8080-LITE min 293.17 40.60 54.00 65.08 81.00 60.90
M17 max 174.62 40.60 54.00 319.33 81.00 0.00
40-8080-LITE min 118.05 40.60 54.00 325.12 81.00 60.90
M18 max 391.24 75.71 98.97 24.60 525.35 454.29
40-8080·LITE min 252,95 75,05 98.97 24.60 576.11 450.32
M19 max 376.43 76.75 98.96 22.91 525.20 460.51
40-8080-LITE min 267.54 75.95 98.96 22.91 576.08 455.68
M20 max 137.52 40.60 54.00 339.90 81.00 0.00
40-8080-LITE min 178.30 40.60 54.00 332.28 81.00 60.90
M21 max 312.59 40.60 54.00 67.39 81.00 0.00
40-8080-LITE min 342.93 40.60 54.00 69.44 81.00 60.90
M22 max 391.24 75.05 98.97 24.60 533.75 450.32
40-8080-LITE min 257.06 75.71 98.97 24.60 576.11 454.29
M23 max 380.54 75.95 98.96 22.91 533.60 455.68
40-8080-LITE min 267.54 76.75 98.96 22.91 576.08 460.51
M24 max 174.62 40.60 54.00 325.12 81.00 0.00
40-8080-LITE min 121.29 40.60 54.00 319.33 81.00 60.90
M25 max 339.26 40.60 54.00 65.08 81.00 0.00
40-8080-LITE min 299.21 40.60 54.00 67.22 81.00 60.90
M26 max 316.74 40.60 54.00 69.44 81.00 0.00
40-8080-LITE min 342.93 40.60 54.00 67.39 81.00 60.90
M27 max 138.87 40.60 54.00 332.28 81.00 0.00
40-8080-LITE min 178.30 40.60 54.00 339.90 81.00 60.90
M28 max 428.56 68.42 98.76 0.00 526.22 1068.04
40-8080-LITE min 123.22 139.36 98.94 0.00 575.93 1405.70
M29 max 428.56 139.36 98.76 0.00 535.06 1405.70
40-8080-LITE min 123.22 68.42 98.94 0.00 575.93 1068.04
M 30 max 797.92 341.90 595.35 0.00 3182.79 2846.54
40-8080-LITE min 255.01 329.98 573.20 0.00 3309.07 2711.72
M31 max 797.92 329.98 595.35 0.00 3130.71 2711.72
40-8080-LITE min 255.01 341.90 563.77 0.00 3309.08 2846.54
M32 max 68.02 68.52 85.21 3.79 357.96 0.00
40-8080-LITE min 68.02 68.52 85.21 3.79 357.96 246.39
M33 max 19.61 136.04 56.63 3.40 339.75 816.24
40-8080-LITE min 127.13 136.04 56.63 3.40 339.75 816.24
M34 max 103.90 42.57 56.63 3.52 89.07 0.00
40-8080-LITE min 189.60 42.57 56.63 3.52 89.07 66.96
M35 max 103.90 42.57 56.63 3.53 89.07 0.00
40-8080-LITE min 189.60 42.57 56.63 3.53 89.07 66.96
M36 max 0.00 122.03 57.08 2.12 342.49 570.97
40-8080-LITE min 109.86 122.03 57.08 2.12 342.49 731.90
M37 max 0.00 122.03 57.11 2.12 342.64 570.97
40-8080-LITE min 109.86 122.03 57.11 2.12 342.64 731.90
M38 max 122.10 19.82 19.11 0.00 20.31 0.00
40-8080-LITE min 95.09 19.81 19.11 0.00 20.31 21.07
M39 max 122.10 19.80 19.11
40-8080-LITE min 95.09 19.83 19.11
M40 max 190.44 28.57 38.00
40-8080-UTE min 243.77 28.57 38.00
M41 max 190.44 28.57 38.00
40-8080-LITE min 243.77 28.57 38.00
M42 max 260.95 235.20 113.70
40-8080-LITE min 278.88 368.39 113.70
M43 max 213.69 28.00 27.00
40-8080-LITE min 213.69 28.00 27.00
M44 max 261.73 235.20 113.70
40-8080-LITE min 278.88 372.50 113.70
M45 max 224.13 28.00 27.00
40-8080-LITE min 224.13 28.00 27.00
0.00 20.31 0.00
0.00 20.31 21.08
456.98 45.68 0.00
456.98 45.68 32.76
457.29 45.68 0.00
457.29 45.68 32.76
57.78 495.57 2090.33
56.61 495.62 1339.15
50.62 40.50 0.00
64.37 40.50 42.00
56.61 495.62 2115.00
57.78 495.57 1339.15
64.37 40.50 0.00
50.62 40.50 42.00
No D/C greater than
1 00% -> All members OK
--·-.. ·.;._;•:•.
>::/:
A19
g;t .. -.
.----,-,21:
• 1.:.ii
. . /.:·,. JJ.O· . .-·
• ·-·:-: ··:2,4i· ·.
•. :·,, .. ~;10 :
l.32
,.,_ .. :1s:;-..
:-:,:_J .12 ,•
::--·2.1:z -:
Torque Specifications
The tables below show the amount of torque in foot-lbs. and
newton meters required to activate the 2 degree drop-lock feature
fort-slotted profiles. Nut and bolt combination is preloaded when
tightened to the minimum torque rating.
Fractional T-slotted Profiles
Part Number Fastener Description
3320 5116-18 x 11116 Flanaed BHSCS & Economv T-Nut 1515
3325 5116-18 x 314 Economv T-Slot Stud, Washer & Hex Nut 1515
3360 15 Series Anchor Fastener Assemblv 1515-Lile
3380 15 Series End Fastener Assemblv 1515-Lite
3321 114-20 x 112 Flanaed BHSCS & Economv T-Nut 1010
3395 10 Series Anchor Fastener Assemblv 1010
3381 10 Series End Fastener Assembtv 1010
Metric T-slotted Profiles
Drop-Lock
Engaged
;...._~===:::i._---,
10.00 15.00
25.00 30.00
10.00 20.00
10.00 22.00
4.00 6.00
3.00 17.00
4.00 17.00
Part Number Fastener Description Tested Profile Minimum Torque Newton Meters Maximum Torque Newton Meters
75-3422 MS x 16mm BHSCS & Economv T-Nut 40-4040 13 20
75-3500 MS x 20mm Economv T-Slot Stud, Washer & Hex Nut 40-4040 40 54
40-3897 40 Series Anchor Fastener Assemblv 40-4040-Lite 13 37
40-3891 40 Series End Fastener Assemblv 40-4040-Lite 13 29
75-3404 M6 x 10mm BHSCS & Economv T-Nul 25-2525 5 8
25-3896 25 Series Anchor Fastener Assemblv 25-2525 4 23
25-3895 25 Series End Fastener Assemblv 25-2525 5 23
The estimated torque calculations in this chart are offered as a guide only. Use of this content by anyone is the sole responsibility of that person and they assume all risk. Due to many
variables that affect the torque•tenslon relationship like human error, surface texture, and luhrication the only way to determine the correct torque is through experimentation under
actualjointandassemblyconditions. Double values since using
(2x) bolts = 5001bs. All shear
Fastener Application Test reactions < 5001bs -> OK
1 : Single Anchor
6: Comer Bracket
7
8
9
2: Double Anchor
7: Comer Gusset
3: End Fastener
8: Inside -Inside
Corner Connector
1010 Profile
: .
500 250 180
900 250 260
450 200 325
4: Flat Plate
9: Inside -Outside
Corner Connector
375
50
240
50 50
220 240
Horizontal Profile Dimension
A: Direct Force
10 Series = 5.000' B: Cantilevered
15 Series = 6.000' C: Tortional Force
700
2000
1,150
200 1,100
200 1,260
225 500
750 500
For the most up to date information on 80/20" products visit 8020.net
A21
3131 Camino Del Rio North, Suite 1080 San Diego, CA 92108 619.521.8500 kpff.com
Quidel
Project Redwood
Clean Room
Anchorage Design
A22
Joint Reactions *red reactions require two anchors Max Reactions
X (lb) Abs Val Y (lb) Abs Val Z (lb) X Max (lb) Y Max (lb) Z Max (lb)
N3 max 951.31 951.31 862.29 862.29 1548.78 951.31 905.99 -947.20
min -285.34 285.34 -249.77 249.77 195.07
NS max 951.31 951.31 847.61 847.61 905.98
min -284.77 284.77 -264.08 264.08 -470.02
N6 max 829.48 829.48 878.01 878.01 1567.60
min -258.48 258.48 -250.89 250.89 -864.35
NS max 820.93 820.93 905.99 905.99 1814.15
min -236.27 236.27 -242.01 242.01 -745.80
NlO max 820.93 820.93 857.79 857.79 25.95
min -235.87 235.87 -291.29 291.29 -947.20
Nl max 829.47 829.47 858.23 858.23 1716.76
min -261.57 261.57 -271.34 271.34 849.33
f = i ·i 5 ;. • ----------------------
Hilti PROFIS Engineering 3.0.91
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter:
Item number:
Effective embedment depth:
Material:
Evaluation Service Report:
Issued I Valid:
Proof:
Stand-off installation:
Anchor plateR:
Profile:
Base material:
Installation:
Reinforcement:
Concrete -Mar 13, 2024
KWIK HUS-EZ (KH-EZ) 3/8 (3 1/4)
418058 KH-EZ 3/8"x3 1/2"
her.act= 2.500 in., hnom = 3.250 in.
Carbon Steel
ESR-3027
4/1/2022 112/1/2023
Design Method ACI 318-19 / Mech
eb = 0.000 in. (no stand-off); t = 0.250 in.
Page:
Specifier:
E-Mail:
Date:
I, x IY x t = 1.570 in. x 2.200 in. x 0.250 in.; (Recommended plate thickness: not calculated)
no profile
cracked concrete, 3000, fc' = 3,000 psi; h = 5.000 in.
hammer drilled hole, Installation condition: Dry
tension: not present, shear: not present; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar
Application also possible with KWIK-X 3/8 (2 1/2) hnom1 under the selected boundary conditions.
More information in section Alternative fastening data of this report.
R -The anchor calculation is based on a rigid anchor plate assumption.
Geometry [In.] & Loading [lb, In.lb]
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hllti is a registered Trademark of Hilti AG, Schaan
A23
3/13/2024
1 = 1· i S • • ----------------------Hilti PROFIS Engineering 3.0.91
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
1.1 Design results
Case
I
Concrete -Mar 13, 2024
Description
Combination 1
Page:
Specifier:
E-Mail:
Date:
Forces [lb] / Moments [in.lb]
N = 947; Vx = 951 ; Vy= 905;
Mx = 0; My = 0; M, = 0;
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademar1< of Hilti AG, Schaan
Seismic
no
A24
2
3/13/2024
Max. Util. Anchor[%]
46
2
i = 1·1 S • • ----------------------
Hllti PROFIS Engineering 3.0.91
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
I
Concrete -Mar 13, 2024
2 Proof I Utilization (Governing Cases)
Loading Proof
Tension Concrete Breakout Failure
Shear Steel Strength
Loading
Combined tension and shear loads
3 Warnings
PN
0.396
Please consider all details and hints/warnings given in the detailed report!
Page:
Specifier:
E-Mail:
Date:
Design values [lb]
Load Capacity
947 2,392
1,313 3,111
Pv r;
0.422 5/3
Fastening meets the design criteria!
Input data and results must be checked for confonnity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Utilization
PN i Pv [%]
40 /-
-/ 43
Utilization PN,v [%]
46
A25
3
3/13/2024
Status
OK
OK
Status
OK
3
i = 1· 1 S • i Hllti PROFIS Engineering 3.0.91
www.hilti.com
Company: Page:
Address: Specifier:
Phone I Fax: I E-Mail:
Design: Concrete -Mar 13, 2024 Date:
Fastening point:
4 Alternative fastening
4.1 Alternative fastening data
Anchor type and diameter:
Item number:
Effective embedment depth:
Material:
Evaluation Service Report:
Issued I Valid:
Proof:
Stand-off installation:
Anchor plateR:
Profile:
Base material:
Installation:
Reinforcement:
KWIK-X 3/8 (2 1/2) hnom1
418057 KH-EZ 3/8"x3" (element)/ 2346658 KHC 3/8"
SMALL (capsule)
h0r,opti = 2.500 in. (hef,limlt = 3.000 in.), hnom = 2.500 in.
Carbon Steel
ESR-5065
1/1/2023 J 12/1/2023
Design Method ACI 318-19 / Chem
eb = 0.000 in. (no stand-off); t = 0.250 in.
I, x ly x t = 1.570 in. x 2.200 in. x 0.250 in.; (Recommended plate thickness: not calculated)
no profile
cracked concrete, 3000, fc' = 3,000 psi; h = 5.000 in., Temp. short/long: 32/32 °F
hammer drilled hole, Installation condition: Dry
tension: not present. shear: not present; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar
Max. Utilization with KWIK-X 3/8 (2 1/2) hnom1: 52 %
Fastening meets the design criteria!
Input data and results must be checked for confonmity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hlltl is a registered Trademark or Hilti AG, Schaan
A26
4
3/13/2024
4
i = 1· 1 5 • • ----------------------A27
Hilti PROFIS Engineering 3.0.91
www.hllti.com
Company:
Address:
5 Page:
Specifier:
Phone I Fax: E-Mail:
Design:
I
Concrete -Mar 13, 2024 Date: 3/13/2024
Fastening point:
5 Remarks; Your Cooperation Duties
Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each
case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data
or programs, arising from a culpable breach of duty by you.
Input data and results must be checked for confomiity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
3131 Camino Del Rio North, Suite 1080 San Diego, CA 92108 619.521.8500 kpff.com
Quidel
Project Redwood
Mechanical Anchorage
{B_GREENHECK
• Building Value in Afr.
Performance
Quantity
Volume (CFM)
Total External SP (in. wg)
Operating Power (hp)
Required Power~:=._
Fan RPM
Max Fan RPM
Oper. Frequency (Hz)
Elevation (ft)
Start-up Temp.(F)
Operating Temp.(F)
1,450
3
1.05
1.05
2434
3,151
60
479
70
70
Fan Configuration
Size 12 -Wheel Type Bl
Arrangement 10
Class I
Rotation cw
Discharge Position UB
Construction Type PermaLock -Spark Resistance None --~roll Material Steel ,_
Wheel Material Steel --Inlet Cone Material Steel
Pedestal Material ~eel
Equipment Weights
Fan (LMD)(lb) 153
Motor/Drive (lb) 35
Accessories (lb) f 0
Fan Total (lb) 188
Misc Fan Data -----
Fan Energy Index (FEI) 1.45
Outlet Velocity (ft/min) 1,680
Static Efficiency ~ 70
Tip Speed _(_ft/min) 7,805 --
Shaft Bearing Type Standard
-
Bearing Life Calculation_ Operating Point
L 10 -Bearing Life (hrs.) 1,000,000
Motor and Drives
Motor Included
Size (hp) 1 1/2
RPM 1725
Enclosure ODP
VICI_!!_ 460/60/3
Frame Size 56
Max Frame Size 145
Location Centered
-
Pulley Type Constant
Drive Loss(%) 6.0
Drives Standard
Drive Service Factor 1.5 --MCN (Amps) 3.75
MOP* (Amps) 15
SCCR* (Kiloamps) 5
Model: USF-12
Universal Single Width Fan
Operating Performance
4.0
2434 FRPM
3.5
3.0
........
C) ~ 2.5
6
Q) .... 2.0 ::,
(/)
(/)
Q) ....
Cut Sheet -Not for Subrui_ttal
Printed Date: 03/0~024
Mark: EF-17A&B
Model: USF-12
3.2
2.8
2.4
2.0 ........ a.
:S
I
1.6 ....
Q)
~ 0 a. 1.2 Q) 1.5 a.
(.)
~
---. ,-----. A·· -------··· ----------------. ·----. .:,£ co .... co co -(/) 1.0
0.5
0.0
0 3 6 9 12 15 18
Volume (CFM) x 100
L. Operating Bhp point 0 Operating point at Total External SP
--Fan curve
-• • -System curve
-------Brake horsepower curve
Nameplate Model: USF-12-3-B6-00-02-02
Sound Power by Octave Band
Sound Data 62.5 125 250 500
Inlet 80 77 80 79
Outlet 96 88 81 80
1000 2000 4000
75 71 68
74 73 69
0.8
0.4
0.0
21 24 27
8000 LwA dBA Sones
63 81 69 16.7
64 82 71 22
Values are estimated and subJect to change. Actual values provided on fan at time of manufacture.
LwA -A weighted sound power level, based on ANSI S1 .4
dBA • A weighted sound pressure level, based on 11.5 dB attenuation per octave band at 5 ft-dBA levels are not licensed by AMCA International
Sones • calculated using AMCA 301 at 5 ft
CAPS4.41.1100
C:\Users\Scott's Laptop\Documents\CAPS\Jobs\24-009 Quidel Redwood Ph2.2.gfcj
Generated by: scott@jrengineering-inc.com Page 1 of 4
( ~ '. ) :
. c i I .
( .:i
C .
X
::. I OC) r ..-"' LO I
r
' .. 'Z_'-1
I C'-J
,-I/ -'-
L 1 J I L.u --✓ '-----------✓
()
n
----1----
~
\' I
, ' I I 'I _._
( J
J
L1 r -------.,
I I
'
( )
: 8 (J) ~-------j
I
I ,-,---°" I L:r.1 ___ ...,
-,
I
I
I
J
-,
(l I
()
0
[
T -
' I
' I ' I \ I \1 I _ _.__
. .
C) C)
0 0
. r
l
I
L -
1 ,.
~ff 1:.Jbli~~~=-o11,.,1 ' I I , /
I
I
(_)
LJ l
L ______ .,
C)
0
hx I ! I
'7'"'
I I
'i'
1-H I
I ! I ~
1-H 2X4FS
~
SubPurlin Effected by
Mech Units
ll~J~l~S~ I ~:F I
2400030
83.
6.75X34.5FS
~
Girder Effected by Mech Units
2.5X27.5FS
~
Purlin Effected by Mech Units
2.5X27.5FS
~
Purlin Effected by Mech Units
2.5X27.5FS -,Q.
Purlin with As-Built Loading
Quidel Redwood Roof SK-7
Mar 26, 2024 at 11 :19 AM
Quidel Redoowd Roof Evaluation.r3d
y
hx
-2.472 lb -2.472 lb -2.472 lb -2.472 lb -2.472 lb -2.472 lb -2.472 lb 84.
~, , r. ~' , ' ~, , , ~,
I .Al
12.
1
875psf • 8' spacing _/
* 48' span/2
"-
-1 03 lb/l't
I r I I I l I I I I I I I I I I l I
-103 lb/l't ,L l I I I I I I I l I I I I l I
-103 lb/l't ,L I I I I I I I I I I I I I l I
12.875psf * 16" r spacing
-17.167 lb/l't I ! 1j I 1111111112;.
Loads: BLC 1, Dead I 1
IIIRISA KPFF Quidel Redwood Roof SK-8
MS Mar 26, 2024 at 11 :20 AM
AJ#:.ME:TI " 1t -1'1' 2400030 Quidel Redoowd Roof Evaluation.r3d
y
hx
-3.84 lb -3.84 lb -3.84 lb -3.84 lb -3.84 lb -3.84 lb -3.84 lb 85.
,, ,, ,, ~, ,, , , ~,
I t A
1 ' _/ ~
20psf * 8' spacing*
48' span/2
6
20psf • 8' spacing
-160 lb/ft
1L I I l I I I I I I I I I
I
-160 lb/ft
1L I I I I I I I I I I I I I l I
-160 lb/ft
1L I I I I I I I I I I I I I l I
20psf * 16"
I r~ri~71 ~ 1111 ! spacing
Loads: BLC 2, Roof Live I
IIIRISA KPFF Quidel Redwood Roof SK-9
MS Mar 26, 2024 at 11 :21 AM
,,.., .... ' ....... Quidel Redoowd Roof Evaluation.r3d 2400030
y
hx -4150 lb -4150 lb
86 .
-100 lb -100 lti40 lb -270 lb -340 lb -140 lb
! !, ! ! ! ! , , ,,
I ~
-200 lb -200 lb
I ! I l l A I
-200 lb -200 lb
I ! I l l :A I
• I
' I ' .,.
-100 Ib
I ! I l A, I
Loads: BLC 3, Mechanical I
IIIRISA KPFF Quidel Redwood Roof SK-14
MS Mar 26, 2024 at 11 :29 AM
,.Nf-,(:[Tii ~~
2400030 Quidel Redoowd Roof Evaluation.r3d
hx
Codect-E ,
(Env)
No Cale
> 1.0
I .90-1.0
I 0.40 .75-.90
.50-.75
0.-.50
I
I 1.18
I
I 1.18
I
I 1.12
I ! I I 0.59 ~
Member Code Checks Displayed (Enveloped)
IIIRISA KPFF Quidel Redwood Roof SK-1
MS Mar 26, 2024 at 11 :45 AM
-~M(fS,.1 < .....,., .. 2400030 Quidel Redoowd Roof Evaluation.r3d
hx
~ I
-83.G
'A ~ ---~ -38.6
-84.6
•~ _'tRO ~ -38.9
-85
-34.5
-80.6
-0.1 A
Member z Bending Moments (kip-ft) (Enveloped)
IIIRISA I ~:F I
Quidel Redwood Roof
:;t,El,l[fS, I -,......._,~ 2400030
B8 ,
~
SK-2
New mechanical
loading only results in
5% increase in
demand -> OK by
inspection
Mar 26, 2024 at 11 :45 AM
Quidel Redoowd Roof Evaluation.r3d
lqJff 3131(aminode1RloN,S1•1080 Project: Quidel Project Redwood
~n0te10,CA9'108 Location: p 619.521 8500 f619 521 3591
-kpffcom Client:
Equip 10:
EQUIPMENT ANCHORAGE
Floor Mounted with Unsymmetrical or Rectangular Multiple Bolt Group Pattern (ASCE 7-16).
Equipment Description
Base
W = weight of equipment
I = overall length
w = overall width
h = height of CG. above base
Center of Mass Location
CG,= dist. in x-dir from Origin
CG,= dist. in y-dir from Origin
n = # of anchors
m =#of bolts@ each anchor
Seismic Accelerations
ap = amplification factor
Rp = response factor
no = overstrength factor
Sos= spectral acceleration
Ip= Imp. Factor (cf. 13.1.3)
Fh = from {13.3-1, 13.2-2, 13.3-3)
Fv = vertical force = 0.2SosW,
Bolt Group properties
x.,., = x-dist. of CR.from Origin
Yt>a, = y-dist. of C.R.from Origin
e, = x-eccen. of CG.from C.R.
e, = y-eccen. of C.G.from C.R.
I,, = Sum (dy12)
1,, = Sum (dx.')
lpo1~rT = IJll + lyl
I,v = Sum (dy12)
l,v = Sum (dx12)
lpo1nv = lxv + lvv
ANCHOR LOCATIONS (up to 20 anchors)
# X y
1 2.00 2.00
2 18.00 2.00
3 2.00 29.00
4 18.00 29.00
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
EF 17A & 17B
250 lb
31 in
20 in
19.00 in
~in
~in
4
2.5
6
2
0.774
1
97 lb
39 lb
10.00 in
15.50 in
0.00 in
0.00 in
729 in'
256 in'
985 in'
729 in'
256 in'
985 in'
z=Cutt
h,=L2-_Jft
Static/Dynamic! Static
Eq 13.3-1
= 0.39 Wp
= 0.16 Wp
Shear in X Shear In Y dx' d/
Yes Yes 64.0 182.25
Yes Yes 64.0 182.25
Yes Yes 64.0 182.25
Yes Yes 64.0 182.25
By: ms !sheet No.: I
Date: 3/26/2024 I
Job No.: 2400030.00
CG, C.G.
EB c.l EB
CG,
0 CD
(0,0)
PLAN AT BASE
z
d' FRONT ELEVATION
246.3
246.3
246.3
246.3
?:\124\2400030_Quldel Project Redwood_2.2\Eng\Equlpment\Equlpment Anchorage Forces_ASCE 7·16.,dsm / EF 17A 176
89
X
3/26/2024
lqJff 3131 CMni~del RION, S1e 10&0 Project: Quidel Project Redwood By: ms l sheet No.: I
San~go,C.A92l08 Location: Date: 3/26/2024 I p 619 S218SOO 1619 Sll 8591
WWN kpff.com Client: Job No.: 2400030.00
Equip ID:
Bolt Forces Note: Negative slgn means orce Is In compression
Tension[!)= •(M,.dy/1,+M,.dx/lyr(0.9W·Fv)/ln•m)
Mx = F• •sin0•h+(0.9W-Fv)•ey
My= F, •cos0•h+(0.9W-Fv)•ex
Search 0 _max from 0° to 359° to get
maximum Tenslon(i) at each A.B.
Notes for Tension Calculations Below:
fl} Use Tmox/or Connection of Ant)lt to Equlpmtnt
ot Vertical Angle Leg (i.e. Screws)
(2) Use Tmox•EF for Conntt:tion of Angle ro Base
at Horizontal Angle Ltg (I.e. Hllti KB Tl}
(3} Ecuntriclty factor arises from non-rigid and Indirect conntction
(EF .z J through equipment, 2.5 single onglt>, -3 channel-plate
This connection is: through equipment or
rigid connection
Tension
r_ = MAX (Tension(!))
Ba.se Connx Eccentricity Factor (EF)
T"""'sT,,._•Ef
TM!dior-c, = T_.,,, (calculated with Omega)
Shear
M, = Fh(sln8'e, + cos8'e,)
V(I) = IMp'dll,.. + Fhl(n'm)I
v_, = Maximum (V(I))
v.,......., = V_, • fl, (Concrete Only)
20 lb/bolt
1.0
20 lb/bolt
87 lb/bolt
24 lb/bolt
48 lb/bolt
Search 0 _max from 0° to 359° to get max V(i) at each A.B.
#
1
2
3
4
e max -M,'dy/I,
30.5 -17.3
149.5 -17.3
329.5 -17.3
210.5 -17.3
# 8 max
1 0.0
2 0.0
3 0.0
4 0.0
?:\124\2400030_Quldel Project Redwood_2.2\Eng\Equlpment\Equ,pment Anchorage Forces_ASCE 7-16.xlsm / Ef 17A 178
M.•dx/I. (0.9W-Fv)/n'n
-49.5 46.6
-49.5 46.6
-49.5 46.6
-49.5 46.6
M. •d/I.,,,., Fh/(n•m)
0.0 24.2
0.0 24.2
0.0 24.2
0.0 24.2
810
1
Tension
20.2
20.2
20.2
20.2
V
24.2
24.2
24.2
24.2
3/26/2024
oroiect Quidel Proiect Redwood sheet no.
l{pft 3131 Camino Del Rio N bv
Suite 1080 811
San Diego, CA 92108 location date
p (619) 521-8500 MA job no. 2400030 f (619) 521-8591 client
I www.kpff.com Rooftop Equipment
Force on LUS hanger = 1 00lbs
Allowable Load on LUS hanger = 800Ibs > 1 O0lbs -> OK 1 00lbs 1 00lbs
i i
Fp force from overturning: I I
T = 20Ibs ~ I,,
V = 24Ibs "I 3' 71
Capacity of #12 Wood Screw:
W = 154Ibs/in * 3" = 462Ibs
W' = 462Ibs*1.6 = 739Ibs > 20Ibs -> OK
Z = 156Ibs W/ 1 OD embed
Z' = 1561bs*1.6 = 250Ibs > 24Ibs -> OK
~
Cl) C)
C: cu J:
-:;; ·o .,
C: 3,: cu "' :2
0 "' I
104
Simpson_ Strong-Tie' Wood Construction Connectors
Face-Mount Hangers -Solid Sawn Lumber (DF/SP)
SIMPSON
Strong-Tie
The Joist Hanger Selector software enables you the most optimum product for your project.
The software takes into consideration all the characteristics seen in this catalog. Visit strongtie.com/jhs.
These products are available with
■ additional corrosion protection.
For more 1nformat1on, see p. 15.
For stainless-ll!:} steel fasteners,
see p.21 .
r.r., Many of these products are approved for installation
~ with Strong-Drive" SD Connector screws.
See pp. 335-337 for more information.
"
.---.--------r--r------r-~-----------...... ----------~--~---
Joist
Size
Model
No.
Dimensions (in.) Fasteners (in.) OF/SP Allowable Loads _ Installed
Ga. '---W--H--B-':~~~'-------------+-U-p-lift--F-lo-or--S-n_o_w--R-oof Cos(tlClnl)dex
Header Joist
1-----L-------.1-....L---.JL--L--'--L---(160) (100) (115) (125)
Sawn Lumber Sizes
LU24 20 rn. 3¼ _!._½ -l-('-'4)_0_.1_62_x_3_½_.J.-.:..(2'-) o_.1_4_8_x_11_½-1-_2_40 _ 5_55~,_6_30 _ 655 Lowest
• LUS24 18 1 o/,o 3¼ 1 ¾ -(4) 0.148 x 3 (2) 0.148 x 3 435 670 765 820 3% 2X4 ---------+------+-------t-------t
u24 16 rn. 3¼ 1 ½ -(4) 0.162 x 3½ (2) 0.148 x 1 ½ 240 575 650 10~ 67%
• HU26 14 mo 3½a 2¼ -(4) 0.162 x 3½ (2) 0.148 X 1 ½ 305 595 670 720 295%
•
l---+------+--,--+--+---+-l--.;..._----+....;.;----+---+--11----+---+----'I LUS24·2 18 3¼ 3¼ 2 -(4)0.162x3½ (2)0.162x3½ 410 800 905 980 Lowest • g~~ ~-2 _ 1~~ 3¼ ~ 3 2 -_ (4) 0.162 X 3½ (2) 0.148 X 3 240 575 650 705 33%
• HU24·2 / HUC24·2 14 31/a 3½• 2½ -(4) 0.162 x 3½ (2) 0.148 x 3 380 595 670 720 240% ~l---+------+-1---+--+--+--+--_;.__---t----'_;.__---+---+--+---+----+---1
i,.u LUS26 18 1 o/,o 43/, 1 ¾ -(4) 0,148 x 3 (4) 0.148 x 3 1,165 865 990 1,060 Lowest -___ .,_ ____ _,.__ _ _._
.__L_U2_6 ____ ,_ 2o__1o/ia ~ 43/~~ --+-_(6-'-)0_.1_6_2_x_3_½--t_(4-'-)_0._14_8_x_1_½-1 ~-835 950 1,030_'---6%
U26 16 mo 43/, 2 -(6) 0.162 X 3½ (4) 0.148 X 1 ½ ~ _ 865 980 1,055 43% ~ 2x6 -<----~
i,.u '---L_UC_2_6_Z ____ 4 18 ~ 43/, 1¾ -(6) 0.162 X 3½ (4) 0.148 X 1 ½ 7_30_.__8_45 __ 9_6_5-+_1_.0_4_0-+-_1_6_0%_-l
• HU26 14 1 '½• 3½• 21/, -(4) 0.162 x 3½ (2) 0.148 x 1 ½ 305 595 670 720 179% ._______ ---+------+ __ __. __ __,_ ---+---+-----!
• HUS26 16 15/s 53/o 3 -(14) 0.162 x 3½ (6) 0.162 x 3½ 1,320 2,735 3,095 3,235 276%
t'D LUS26-2 I~ 3~~•-1-_2~'---l-('-'4)'-0_.1_62_x_3_Y:_2 (4) 0.162 x 3½ 1,060 1,030 1,170 1.265 Lowest
U26-2 16 3¼ 5 2 -(8)0.162x3½ (4)0.148x3 535 1,150 1,305 1,410 65%
•
DBL
2X6
TPL
2x6
2x8
HUS26·2
HU26·2 / HUC26·2
LUS26·3 '-U26·3 >----
HU26-3 / HUC26·3
LUS26
LU26
LUS28 C-
LU28
-
(4) 0.162 X 3½ (4) 0.162 X 3½ 14 31/a 53/,& -~ 2 -1,165 1.055_ 1,195 -~ 1,~ 172%
14 3¼ 4"½, 2½ Min. (8)0.162x3½ (4)0.148x3 755 1,190 ----1,345 1,440
--L---
14 31/a 4"¾• 2½ Max. (12)0.162x3½ (6)0.148x3 1,135 1,785 2,015 2,165
-~-4_%-1-_4'_¼4 2__ (4)0.162x3½ (4)0.16~ 1060 1,030 1,170 1,265
16 45/s 41/, 2 _ +---(_8)_0_.16_2_x_3~ (4)0.148x3 5_3_5_..._1_,1_5_0.....__1_,3_05__,_1.410_
233%
254%
14 41½& 41%2 2½ Min. (8)0.162x3½ +---'-(4.;.)_0._14_8_x_3 __ 7_55_'---1_,19_0_..._1_,345 ~44_0_,__
14 4% 4% 2½ Max. (12)0.162x3½ (6)0.148x3 1,135 1,785 2,015 2,165
18 ~ 4¾ 13/, -(4) 0.148 X 3 (4) 0.148 X_3_ 1,165 865-+_9_90_-l--1'-,0_60--I
20 1'½• 4¾ 1½ -
18 1o/,, 65/s 1¾ -
(6) 0162 X 3½
(6) 0.148 X 3
20 rn. 6~,_1~,_ -~ (8) 0.162 X 3½
16 1o/i6 4¾ 2 -(6) 0.162 X 3½
(4) 0.148 X 1 _½__,__5_40____, 835 950 1,030
(4) 0.148 X 3
(6) 0.148 X 1 ½
(4) 0.148 X 1 ½
1,1~-1,10~~-260 __ 1.350
850 1,110 1,180 1,180 -535 865 980 1,055
Lowest
6%
23%
39%
43% U26
LUC26Z
HU28
HUS26
HUS28
LUS26·2
LUS28·2
----+-18 rn. 43/, 1¾ -(6)0.162x2Y:._ (4) 0.148 X 1 ½ 730 845 965 1,040 160%
251%
DBL '---U_26_·_2 __
• 2x8 HUS28·2
•
TPL
2X8
HU28-2 / HUC28·2
LUS28·3
U26-3 -
HU26·3 / HUC26·3
14 H-\6 51/, 2¼ -(6) 0.162 X 3½ (4) 0.148 X 1 ½ 605 895 1,010 1,080
16 15/s 53/o 3 -(14)0.162x3½ (6)0.162x3½ 1,320 2,735 2.845 2,845 276% --
16 1 % 7 3 -(22) 0.162 x 3_½-+-'-(8'-l o_.1_6_2_x _31_v.-+_1,7_6_o-+_4_.o_95-+_4_._o9_5_,__4_,o_9_5-+-_4_o_9'_1<,-1
18 31/a 47/e+--2-+----l--'-(4)0.162x3½ (4)0.162x3½ 1,060 1,030 1,170 1,265 Lowest
18 3¼ 7 ~ -(6)0.162x3½ (4)0.162x3½ 1.060 1,31_5...j.._1;_,4_90--1__:1,_61_0-1-_.8_%_
16 3¼ 5 2 -(8) 0.162 X 3½ -t--'-(4_) _0._14_8_x_3_t-_53_5--t_1,_1_5_0-+-_1,305 1.41<!_~ 65%
1~e-3¼-1-7_'l-l_•-l--2-i-----1--'(6_.:.)_0_.16_2_x_3_½_f-(:..:6)_0.162 X 3½ 1,320 1,580 1,790 1,930 -~8%
14 3¼ 6¥11 2½ Min. (10) 0.162 X 3½ (4) 0.148 x 3 755 1,490 _;1,'-68_0_..._1..:.,8_0_0-l-397%
14 3¼ 6¥1• 2½ Max. (14) 0.162 x 3½ (6) 0.148 x 3 1,135 2,085 2,350 2,530 418%
18 41/o 6¼ l--2--1----1--'(6) 0.162 X 3½ (4) 0.162 X 3½ _1._06_0 1,315 1,490 1,610
16 4% 4¼ 2 -(8)0.162x3½ (4)0.148x3 535 1,150 1,305 1,410
14 4'½• 45/s 2½ Min._ (8)0.162x3½ ~)0.148x3
14 4'½• 45/s 2½ Max. (12)0.162x3½ (6)0.148 x3
755 1,190 1,345 1,440 --
1,135 1,785 2,015 2,165
-
--f--------1----+--(4) 0.162 X 3½ 755 1,490 1,680 1,800 • QUAD HU28-4 / HUC28-4 2X8
14 6¼ 7 2½ Min. (10) 0.162 x 3½ -------1------'-----+-14 61/4 7 2½ Max. (14) 0.162 x 3½
----+---➔---~ --
(6) 0.162 X 31h 1.135 2,085 2,350 2,530
Code
Ref.
IBC, Fl, LA
IBC, FL
IBC, FL, LA
IBC. FL
See footnotes on p. 108. Codes: See p. 12 for Code Reference Key Chart
UPDATED 06/01/19
2
813
[§§]
s <. s--------------------
'
Product Drawin Unit Tag:
Product: Project Name:
Sales Office: Norman 5. Wright-Climatec Meehl Equip
Sales Engineer:
Model: BCHD0101 Apr. 01, 2021 I Ver/Rev: Sheet: 1 of 1 Scale: NTS Tolerance:+/· 0.25" I Dwg Units: in [mm)
.DAIKIN
13600 Industrial Parl< Blvd. Minneapolis, MN 55441
www.DaikinApplied.com Software Version: 04.20
No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.
Proj•ct
1<¢.f 3231 Camioo del Rio N, Stit 1080 Quidel Project Redwood
San Diego, CA 92108 Location
p 619.521 8500 f 619 S21 8591
wwwkptfcom Job No
SEISMIC FORCES ON COMPONENTS
Per ASCE 7-16, Chapter 13
All Coefficients are in terms of "Wp"
ASD LRFD
., Sh .. t
Oat~
3/2024
Revised
Sos=a§.774 f ph,mu: = 0.88
1. = 1.0 Fph,min = 0.17
1.24
0.23
~
Static/ Dynamic?~Eq 13.3-1
Apply Omega?~
h = 30 ft (Total Building Fov = 0.11
ASD LRFD
a•= 2.5
Ro= 6 n = 2
,_
p
~
LEVEL HeiRht {ftl z/h Foh Foh
0.00 0.00 0.00 0.00 0.00 0.23 0.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.23 0.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.23 0.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.23 0.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.23 0.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.23 0.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.23 0.00 0.00 0.00 -Roof 30 1.00 0.00 0.00 0.00 0.00 0.39 0.00 0.00 0.00
3 14 0.45 0.00 0.00 0.00 0.00 0.25 0.00 0.00 0.00
2 0 0.00 0.00 0.00 0.00 0.00 0.23 0.00 0.00 0.00
W0 = Component Operating Weight f = I • 2-04(Sw W, ( :)
a0 = Component Amplification Factor, Table 13.5-1 or 13.6-1 ' h
RP= Component Response Modification Factor, Table 13.5-1 or 13.6-,.
S05 = Spectral Accelration, short period from §11.4.S Static
10 = Component Importance Factor, §13.1.3
z = Component Attachment Height with Respect to Grade, 2:0 but not more tharf'ph,max = I .6S os I PW P
h = Average Roof Height of Structure with Respect to Grade
ai = maximum acceleration at level I obtained from modal analysis and not less thanf ph ,min = 0 .3 S DS I P W P
Ax = torsional amplification factor Eqn {12.8-14)
"The horizontal seismic design force (Fp) shall be applied at the componen's center of gravity
and distributed relative to the component's mass distribution and shall be determined in accordance with Eq (13.3-1)"
Remember to apply F = +0.2SD·"W pt• -, p
B14
14!ff 3131 Camino Del Rio N ro·ect Quidel Pro·ect Redwood
Suite 1080
San Diego, CA 92108
p (619) 521-8500
r ul , f (619) 521-8591
Er II r www.kpff.com
Ceiling Hung Equipment
W = 4001bs max
Fph = 0.25 W
Fpv = 0.15 W
Vertical threaded rods
location
client MA
Tu = 1.2W + Fpv = 1.35 W = 540 lbs / 4 hangers
= 135 lbs per hanger
3/8" <P rods are ok by inspection
Load to screws
P1000 l.NISTII\II
,·L ,1c;,., 8llfl t J" • J.
•/ (2) 112 ws, ,·L
12t?. acr,n t , •.. r .. ;
"'"""'
216 81.1t'G
Tmax = 1.0W + 0.7Fpv = 1.105 W = 442 lbs/ 4 hangers/ 2 Wood Screws
= 55 lbs per screw
#12 Wood Screw into face of blocking
Assume 6d min penetration
Z = 156 lbs * 1 .296"/2.16" = 93.6Ibs > 55Ibs -> OK
Cable brace
Tmax = 0.7*Fph / cos (45deg) = 100 lbs/ 2 braces= 50Ibs / brace
Cable brace is ok by inspection
Load to screws
Vmax = 50 lbs per brace/ 3 screws per brace
= 20Ibs/ screw
Tmax = 50 lbs per brace/ 3 screws per brace
= 20Ibs/ screw
#12 Wood Screw bottom of blocking
Cd= 1.6
Z' = 93.6 lbs * 1.6 = 149.81bs
W'p = 154 lb/in* 1.296 * 1.6 = 319.3Ibs
Z'a = (W'p)*Z'/((W'p)*cos(45°)A2+Z'*sin(45°)"2
= 203.91bs
Check Nailer
Load per hanger = 1 00lbs
16d nail into 1 1 /2" side member
z = 141 lbs
Z' = 126Ibs/ nail -> OK
sheet no.
b 815
date
job no. 2400030
V
@ PLAN VIEW
oroiect Quidel Proiect Redwood sheet no.
' l{pf:f 3131 Camino Del Rio N bv
Suite 1080 B16
San Diego, CA 92108 location date
p (619) 521-8500 MA f (619) 521-8591 client job no. 2400030
E t1 I r www.kpff.com
Ceiling Hung Equipment 1 00lbs 1 00lbs DL = 60plf i L Existing Roof Check w/ Suspended unit LL = 167plf
(E) Wood framing • • • • +
26" TJI@ 16" I I
SDL = 45psf ~ 24' ~
LL= 125psf /I ,,
Original Mmax = 16.344k'
New Mmax = Pa + wl"2/8 = 10001b' + 16344Ib'
= 17.344k'
= 6% Change, OK by inspection
Check Unistrut P1000
Length of equipment= 37"
Dist Load = 65plf
Allowable load = 500Ibs > 200Ibs -> OK
Table 1 2N
Ii i j jJ 'ii 'Z
i. D
in. in.
:,-~ 0 Oilll
011:l
0.120
0 128
01J'
01J!>
014tl
0 182
0 177
0 192
0207
0Z25
0?44
1 O.Dfl!l
0113
0 120
0~
0.131
0.13S
0.1,11
o 1ei
0111
0 192
0.207
0.225
0244
1-t/4 0099
0113
O.l20
0128
013,
0.135
014&
0 162 o ,,,
0.192
0.207
0.225
0 244
1-1/2 0 099
0 113
0.120
0128
0.131
0.1'.lS
0.148 o, .. ,
0177
0192
0.207
0 225
0 2"4
3131 Camino Del Rio N
Suite 1080
San Diego, CA 92108
p (619) S21-8500
f (619) 521-8591
www.kpff.com
ro·ect Quidel Pro·ect Redwood
location
client MA
sheet no.
b B17
date
job no. 2400030
COMMON, BOX, or SINKER STEEL WIRE NAILS: .Reference Lawal Design I
Vahles, Z, for SlngJe Shear (two member) Connections1,a.s !..___.___
for sawn l001ber or SCL wlUl both members of ideotlcal specific gravity (tabulated lateral design values
are calculated based on an assumed length of nail penetratlol\ p Into the main member eQual to 10D) '
1 ~ ~ 1111
..
L. ... -! f 1l cij u.
:= :i. t ifz d, .§ I u. Ji g i .. ii ;ii .. ~1:B Iii !~ j il ii ~,j~I ;! i l
<OO ~ J!ll 8 i ! )~ ~ z ,•. JI.fl Ii
Pllflll-laht bs. lbs. lbs. l>s. ID• lbs lbs bs. lb•. lbs
ij<f 10 7'J 61 !lo$ $4 51 ""' 47 311 JII :16
~d 8d eel 94 19 72 71 ~5 1111 57 47 -4B «
IOd 107 M 90 77 71 M 6:2 52 50 '8
10d 121 101 87 84 76 70 68 57 56 5'
811 1Z7 ...... 90 8 8.l) J 70 eo 58 ~
16d 12d 135 108 ~ 91 84 16 74 63 61 5e
101l '();I 1&o 1 !l4 1,1 105 107 ~ 86 $3 10 G9 00
16d 40d 183 1l8 121 117 108 99 ,_ 96 ,__!!. 80 -77
20d 200 153 1l4 130 121 '11 107 ~2 90 87
20d 301 206 157 13& 13-1 125 • 1• 11· 96 93 IIO
JQO 0d ,_216 166 147 3 13,,l l.z! 19 03 I 8
400 229 178 158 154 144 132 129 112 110 106
60d GDd 2:14 ,a, 11;;~ 158 147 1~ 13? 115 113 109
8d 7d ,a &1 55 64 51 48 47 42 41 40
ltd' 8d 11d 9" 79 '12 71 67 6.J 61 5$ 54 $1
10d 10, AS 81 eo ,g 11 119 80 ~9 66
10d 121 101 93 91 a6 80 7'9 66 64 &1
8d 127 108 97 95 90 84 112 611 ll6 83
16d 12d 135 113 109 101 96 89 118 71 69 68
10d 20d 16d 154 123 118 115 109 99 96 80 77 74
1&d 1100 1114 1~ 141 137 125 • 1J ,ot 9• 89 a!.
20<1 113 1111 1!>!> 1,0 138 ·~ 12, 102 99 !II(>
20d 301 222 183 59 154 1•2 -•211 124 ·~ 102 919
31ld 40d 243 192 167 182 149 35 13• 111 109 10.
,lQd 268 202 177 171 Hill U4 1<10 120 117 112
50d 60d 274 207 181 175 162 •,is 10 123 120 115
/Jd' 7d1 73 61 65 5'I s, 48 47 ,2 ., 40
6d' 8cl ad' 94 79 T2 71 87 11:s 61 !l!I 114 S2
0d 107 89 81 80 76 71 B9 -10d 1Z1 101 93 91 86 80 79 70 fi9 67
80. 127 tel8 97 95 90 M 112 73 72 70
16d 12d 135 113 103 101 98 89 88 ~ 76 74
10tl 20d 16d 15,C 1211 118 11S 109 ·02 100 89 87 84
19d 110d 184 1$4 1<11 138 131 •22 120 IOl 100 116
20d ~ 1111 Uil 1MI 1(>1 '41 .... 113 110 ·~ ,_
20d 30d 222 1&5 170 166 167 45 140 118 113 108
30d 40d 243 203 188 182 169 152 147 123 119 114
40d 268 w 200 193 177 160 155 130 127 121
50" 60d 276 2'.Vl ..... 1117 181 '6J 1511 ,-.. 129 1:?4
7d' 7S 61 S5 54 51 48 •1 '2 ., "° tJtJ' M' !M 79 72 71 87 83 61 !15 5,4 112
10d 107 88 111 80 78 71 e9 62 to 6l9
10d 121 101 93 91 116 l!O 79 70 69 ff7 ,.,. 127 106 97 95 110 M 112 73 72 70
Hid 12<1 135 113 103 101 ~ 8,9 88 7B 76 74
,,... ,~ -~ ..... J?II 1111 115 IO!I •n, 1nn 89 87 84
.. A ,4nrl -, ... 1"4 141 138 1~1 17' 1:>n -I
;l)Q 2t:) 178 16'.l ,,v 1$1 141 1:)8 12:) 1'1 117
20d 30d 222 185 t70 168 157 U7 144 128 126 1210
30d 40d 243 203 188 Ul2 172 161 1~ 135 131 125
40d 268 2216 205 201 190 178 172 143 138 132
50d 60d 276 230 211 206 186 '81 175 146 141 135
P1000 & P1001 Channels
P1000 • BEAM LOADING
Defl. at Uniform Loading at Deflection Max. Allowable Uniform
Span Uniform Load Load Span/180 Span/240 Span/360
In Lbs In Lbs Lbs Lbs
24 1,690 0.06 1,690 1,690 1,690
36 1,130 0.13 1,130 1,130 900
48 850 0.22 850 760 500
60 680 0.35 650 480 320 ----
72 560 0.50 450 340 220
84 480 0.68 330 250 160 ---96 420 0.89 250 190 130
108 380 1.14 200 150 100
I----
120 340 1.40 160 120 80
144 280 2.00 110 80 60 ------
168 240 2.72 80 60 40
192 210 3.55 60 50 NR -216 190 4.58 50 40 NR
240 170 5.62 40 NR NR
P1000 -COLUMN LOADING
Max. Allowable Maximum Column Load Applied at C.G. Unbraced Load at
Height Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs
24 3.550 10,740 9,890 8,770 7,740
36 3,190 8,910 7,740 6,390 5,310
48 2,770 7,260 6,010 4,690 3,800
60 2,380 5,910 4,690 3,630 2,960 ---72 2,080 4,840 3,800 2,960 2,400
84 1,860 4,040 3,200 2,480 1,980 -96 1,670 3,480 2,750 2,110 1,660
108 1,510 3,050 2,400 1,810 ..
--120 1,380 2,700 2,110 .. ..
144 1,150 2,180 1,660 .. ..
P1000/P1001 • ELEMENTS OF SECTION
Parameter P1000 P1001
Area of Section 0.555 ln2 1.111 ln2
Axis 1-1
Moment of Inertia (I) 0.185 In' 0.928 In'
Section Modulus (S) 0.202 ln3 0.571 ln3
Radius of Gyration (r) 0.577 In 0.914 In
Axis 2-2
Moment of Inertia (I) 0.236 In' 0.471 In'
Section Modulus (S) 0.290 ln3 0.580 ln3
Radius of Gyration (r) 0.651 In 0.651 In
IM#inll,l•MM,,.__;_ .. __ ~~~
UNISTRltT~
P1001 • BEAM LOADING
Dell. at Uniform Loading at Deflection Max. Allowable Uniform
Span Uniform Load Load Span/180 Span/240 Span/360
In Lbs In Lbs Lbs Lbs
24 3,500' 0.02 3,500' 3,500' 3,500'
36 3,190 0.07 3,190 3,190 3,1 90
48 2,390 0.13 2,390 2,390 2,390
60 1,910 0.20 1,910 1,910 1,620 --72 1,600 0.28 1,600 1,600 1,130
84 1,370 0.39 1,370 1,240 830 ---
96 1,200 0.51 1,200 950 630
108 1,060 0.64 1,000 750 500 ------
120 960 0.79 810 610 410
144 800 1.14 560 420 280 -168 680 1.53 410 310 210
192 600 2.02 320 240 160 -216 530 2.54 250 190 130
240 480 3.16 200 150 100
P1001 • COLUMN LOADING
Max. Allowable Maximum Column Load Applied at C.G. Unbraced Load
Height at Slot Face
In Lbs
24 6,430
36 6,290 ---48 6,160
60 6,000
72 5,620
84 5,170 --96 4,690
108 4,170
120 3,690
144 2,930
Notes:
• Load limited by spot weld shear.
"Kl/r > 200
NR = Not Recommended.
K =0,65
Lbs
24,280
22,810
21,410
20,210
18,970
16,950
14,890
12,850
10,900
7,630
K = 0.80 K =1,0 K = 1.2
Lbs Lbs Lbs
23,610 22,700 21,820
21,820 20,650 19,670
20,300 18,670 16,160
18,670 15,520 12,390
16,160 12,390 8,950
13,630 9,470 6,580
11,190 7,250 5,040
8,950 5,730 3,980
7,250 4,640 ..
5,040 .. ..
1. Beam loads are given in tgtru uniform load (W Lbs) not uniform load (w lbs/ft or
wlbs/in).
2. Beam loads are based on a simple span and assumed to be adequately laterally
braced. Unbraced spans can reduce beam load carrying capacity. Refer to Page 62
for reduction factors for unbraced lengths.
3. For pierced channel, multiply beam loads by the following factor:
"KO" Series ....... 95% "T" Serles .......... 85%
"HS" Serles ....... 90% "SL" Serles ........ 85%
"H3" Series ........ 90% "DS" Series ........ 70%
"WT" Series ....... 85%
4. Deduct channel weight from the beam loads.
5. For concentrated midspan point loads, multiply beam loads by 50% and the
corresponding deflection by 80%. For other load conditions refer to page 18.
6. All beam loads are for bending about Axis 1-1. •
I
I
-----48 Q[l-----------,
112 81 l D
TOP VIEi,,/
-------Y60[}-----------------,
------+l6.21>-------------i
/
cs:,
_c:::::,, ______ c=::::t __ _ -----------------------------------------------------------------------~ -----
--c==II--
...... -=--...............
-----------------------
8
4' x 7' Junction Box
Reriovo.1:Jle Top Access
Po.net
Corner Post
Heo.cier
Vert,co.l So.sh
Blower Switch
light Switch
Baffle Slots
Vertical So.sh
I 377' 96 CM
2 43.7' 111 CM
3 55.7' 141 CM
110-115 v, 50/60 hz, 10 aMp
208-230 V, 50/60 hz, 5 OMp
no two two services
lserv,cesl serv,cesl 8. GFCl
oo 1-102
20 21
weight 1210Ibs
700
R~seci So.sh Extens~n
Epoxy Coo ted SST Duet Coll or
Bypass Block
UJ)ppr Interior Depth
59:.oo Upper Bo.Hie
Upper So.sh Tro.ck
-ti-I I Upper Access Po.net
95:.oo
Micicile Bo•fle
UPPER CABINET
LOWER BAS[
,,.e,.. Interior-Depth
36:oo Lower Baffle
741 I Lower Access Po.net
Floor
\.JLl'-ILI
8' Protector
ModeL 1128X
Exterior Suoer~
• Double Woll Con
Interior Supers
• Go1van1zed Ste~
Left ' Right F
• Powder Coated
Liner Mgterigl
• WESI..INER • 3/'
Side Panels
• Both Sides • Rt
Electrical Fixtu
• Provided by LAE
• Fluorescent Ligh
• Single Point COf
• Croy P!ostic Co,
• GfCI ( on elec Im
Sslfil!.
• Vertical Travel
• 3/16. Tempered
• Counter-We,ghte
• 1 .J/16" Pulley '
~
• WESUNER • J/1
Interior Accesc:
• Right ond left
• Casket Provided
Corner Post w
• Right and Left '
• 18 Gouge Cold I
Wiring
• Fume Hood WtrE • Electrical Sen11c1
Junction Box
Service Fixturt:
• LobCOl"ICO • Col
~ • COl"lneChOl'\S M< • Fino1 c:onnectio
• Pre-Piped to '\
• Standard Cos I • Standard Wate1
• Kit for Air ond
Exterior ch
Interior ciE
Interior-ciE
De scrip t,on
0 Ser"vices
2 Services,
2 Services.
Face veloc
100
80
60
Assembly and
• Pre-Assembled
• Polietized
sheet no.
lq:!ff 3131 Camino Oel Rio N oroject bv
Suite 1080 820
San Diego, CA 92108 location date
p (619) S21-8500
C n 111 ,< f (619) 521-8591 client job no.
E• , www.kpff.com
Fume hood weight = 1220lbs*1 _25 = 1500Ibs
Use ASCE 7-16 CH 13
Sds = 0.774
ap = 2.5
Rp = 6
Omega= 2
Z/h = 8/ 30 = 0.267
Fp = [0.4(ap)(Sds)/Rp](1 +2(z/h)) = 0.198Wp
Fpmin = 0.3Sdslp = 0.232Wp -> Governs
Fp = 350Ibs/2 anchor locations = 175Ibs/ anchor
Use SD10112 -> 173Ibs*1.6 = 277Ibs > 1751bs -> OK
Use (2) #10 sms
-= ~
fume hood
= rn
IBI !Bl
ij ij
., Simpson Strong-Tie" Fastening Systems Technical Guide SIMPSON --Connector/Steel-to-Wood Fastening
Strong,Orive ·
Strong•.:ne_
SD CONNECTOR an d SD CONNECTOR SS Screw
Codes/Standards: ICC-ES ESR-3046 (including Qty of LA Supplement); State of Florida FL 9589
For more infonnation, see pp. 69---70, C-F-2023 Fastenmg Systans catalog
SD/SD SS -Allowable Shear Loads -
Steel/Stainless Steel Side Plate
~ a JI "'''''\>
Size x ' I ~~ ~ableShearloadsOb.) Length Model
(in.) No. I (11.) SPF/HF
#9x 1½ S09112SS/ S09112 171 112
#9x2½ S09212SS / S09212 200 112 1.0 #10 X 1 ½ S010112 173 138
#10x 2½ S010212 215 165
1 . Loads am QMlll lor Co = 1 oo and may be ncraased ro lood <balm per the buldlng code 10 Co = 1 60.
2.StooVst81fiess steel Slde-~ate thickness is 33 to 100 mil (20-12 ga.)
----1 ½" -2½" ---►
SD/SD SS -Allowable Shear Loads for Wood Connections
Size X Tlv-ead Reference DFUSP Allowable Shear Loads Ob.) Reference SPF/HF Allowable Shear Loads Ob.)
--Model Length No length Wood Side Plate Thickness (in.)
(in.) fm.) '%2-½ %-o/4 1½ "hz-½ •½:,-¾ 1½
Wood Side Plate Thickness (in.)
#9x 1½ S091 12/S09112SS 105 --93 --
#9x2½ S09212 / S09212SS 118 133 130 99 94 109
1.0 #10x11-, S010112 127 --102 --
#10x2'h S010212 147 168 152 106 126 123
SD/SD SS -Allowable Withdrawal Loads -
DFL, SP, SPF, HF Lumber
Sizex Thread
Reference Withdrawal Des1!J! Value,
Model Head Diameter W Ob. I in.) Length No. '
Length
fm.) -SPF and HF (in.)
I
(11.) Mam Member
#9x 1½ S091 12 / S09112SS 173 122
#9x2½ S09212 / S09212SS ----.v u.u
#10 X 1 ½ S010112 173 122
#10x2'h S010212
203
Screw Capacities
Table Notes
1. Capacities based on AISI SlO0 Section E4.
2. When connecting materials of different steel thicknesses or
tensile strengths, use the lowest values. Tabulated values
assume two sheets of equal thickness are connected.
3. Capacities are based on Allowable Strength Design (ASD) and
include safety factor of 3.0.
4. Where multiple fasteners are used, screws are assumed to
have a center-to-center spacing of at least 3 times the nominal
diameter (d).
5. Screws are assumed to have a center-of-screw to edge-of-steel
dimension of at least 1.5 times the nominal diameter (d) of the
screw.
6. Pull-out capacity is based on the lesser of pull-out capacity in
sheet closest to screw tip or tension strength of screw.
7. Pull-over capacity is based on the lesser of pull-over capacity for
sheet closest to screw header or tension strength of screw.
8. Values are for pure shear or tension loads. See AISI Section E4.5
for combined shear and pull-over.
9. Screw Shear (Pss), tension (Pts), diameter, and head diameter
are from CFSEI Tech Note (F701-12).
10. Screw shear strength is the average value, and tension strength
Is the lowest value listed In CFSEI Tech Note (F701-12).
11. Higher values for screw strength (Pss, Pts), may be obtained by
specifying screws from a specific manufacturer.
Allowable Screw Connection Capacity (lbs)
HScrtw #8 Screw 110Screw '12Screw Y,"Screw
ThlckneH Design Fy Fu (PH • 6'3 Iba, Pts • "19 lbs) (PH• 1278 Iba, Pts • 586 Iba) (Pas• 16" Iba, Pts • 1158 lbs) (P11• 2330 lbs, Pts • 2325 Iba) (PH• 3CM8 lbl, Pts • 3201 lbl)
Yltld T1n1lle (MIii) Thlckn111 (kll) (klij 0.136" dla, 0.272" Hlad 0.16"" dla, 0.272" Head 0.190" dla, 0.3"0" Head 0.216" dla, 0.3"0" H11d D.250" dla, o.<&09" HNd
Shear Pull-Out Pull-Over Shear Pull-Out Pull-Over Shear Pull-Out Pull-Over Shear Pull-Out Pull-Ovar Shear Pull-Out Pull-Ovar
18 0.0188 33 33 44 24 84 48 29 84 52 33 105 55 38 105 60 44 127
27 0.0283 33 33 82 37 127 89 43 127 96 50 159 102 57 159 110 66 191
30 0.0312 33 33 95 40 140 103 48 140 111 55 175 118 63 175 127 73 211
33 0.0346 33 45 151 61 140 164 72 195 177 84 265 188 95 265 203 110 318
4] n n451 33 45 ,. 79 ,., a, na 280 124 345 302 144 415
54 0.0566 33 45 214 100 140 344 118 195 370 137 386 394 156 433 424 180 521
68 0.0713 33 45 214 125 140 426 149 195 523 173 386 557 196 545 600 227 656
97 0.1017 33 45 214 140 140 426 195 195 548 246 386 777 280 775 1,016 324 936
118 0.1242 33 45 214 140 140 426 195 195 548 301 386 777 342 775 1 016 396 1 067
54 0.0566 50 65 214 140 140 426 171 195 534 198 386 569 225 625 613 261 752
68 0.0713 50 65 214 140 140 426 195 195 548 249 386 777 284 775 866 328 948
97 0.1017 50 65 214 140 140 426 195 195 548 356 386 777 405 775 1,016 468 1,067
118 0.1242 50 65 214 140 140 426 195 195 548 386 386 777 494 775 1 016 572 1 067
Weld Capacities
Table Notes
1. Capacities based on the AISI SlO0 Specification Sections E2.4 for
fillet welds and E2.5 for flare groove welds.
2. When connecting materials of different steel thicknesses or
tensile strengths, use the lowest values.
3. Capacities are based on Allowable Strength Design (ASD).
4. Weld capacities are based on E60 electrodes. For material
thinner than 68 mil, 0.030" to 0.035" diameter wire electrodes
may provide best results.
5. Longitudinal capacity is considered to be loading in the direction
of the length of the weld.
6. Transverse capacity is loading in perpendicular direction of the
length of the weld.
7. For flare groove welds, the effective throat of weld is
conservatively assumed to be less than 2t.
8. For longitudinal fillet welds, a minimum value of EQ E2.4-1,
E2.4-2, and E2.4-4 was used.
9. For transverse fillet welds, a minimum value of EQ E2.4-3 and
E2.4-4 was used.
10. For longitudinal flare groove welds, a minimum value of
EQ E2.5-2 and E2.5-3 was used.
Allowable Weld Capacity (lbs/ in)
Thickness Design Fy Fu FIiiet Welda Flare Groove Welds
Yltld Ten1He (MIi•) ThlckneH (kli) (kli) Longitudinal Transverse Longitudinal Tranaversa
43 0.0451 33 45 499 864 544 663
54 0.0566 33 45 626 1084 682 832
68 0.0713 33 45 789 1365 859 1048
97 0.1017 33 45 1125 1269 . 1 1
54 0.0566 50 65 905 1566 985 1202
68 0.0713 50 65 1140 1972 1241 1514
97 0.1017 50 65 1269 1269 1 1
'Weld c;ipacity for material thickness greater than 0.10• requires engineering Judgment to determine leg of welds, WJ and W2.
,,,,
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Quidel Redwood Phase 2.2
2285 Rutherford Road
San Diego, CA 92008
Project Designer:
Mcfarlane Architects
6256 Greenwich Drive Suite #510
San Diego, CA 92122
858-453-1150
Report Prepared by:
J&R Engineering & Consulting, Inc.
16769 Bernardo Center Drive, Suite 1 #768
San Diego, CA 92128
619-823-2909
Job Number:
24-009
Da-
4/4/2
CBC2024-0103
2285 RUTHERFORD RD
QUIDELORTHO : IN Tl OF 1,164 INCLUDING PLUMBING
MECHANICAL AND ELECTRICAL '
The EnergyPro computer program has been used to perform the calculatio1
authorized by the California Energy Commission for use with both the R1
This program developed by Energ
2120620800
4/12/2024
CBC2024-0103
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form NRCC-MCH-E Mechanical Systems 3
STATE OF CALIFORNIA
Mechanical Systems CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-~
This document is used to demonstrate compliance for mechanical systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive -
path outlined in 140.4, or 141.0(b}2 for alterations.
Project Name: Quidel Redwood Phase 2.2 !Report Page: (Page 1 of 11)
Project Address: 2285 Rutherford RoadjDate Prepared: 4/4/2024
A. GENERAL INFORMATION
01 Project Location (city) San Diego 04 Total Conditioned Floor Area 1696
02 Climate Zone 7 05 Total Unconditioned Floor Area 0
03 Occupancy Types Within Project: 06 # of Stories (Habitable Above Grade) 2
• Support Areas • All Other Occupancies
B. PROJECT SCOPE
This table Includes mechanical systems or components that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in
140.4, 170.2(b) or 141.0(b}2 and 180.2{b}2 for alterations.
01
Air System(s)
[8:1 Heating Air System □
[8:1 Cooling Air System □
Mechanical Controls □
[8:1 Mechanical Controls (existing to remain, altered □ or new)
□
□
CA Building Energy Efficiency Standards -2022 Nonresidential Compliance
02
Wet System Components
Water Economizer
Pumps
System Piping
Cooling Towers
Chillers
Boilers
Generated Date/Time:
Report Version: 2022.0.000
C:rhPm::11 \/10rc:inn. rt,\I ,n,,n1 n1
□
□
□
□
[8:1
[8:1
03
Dry System Components
Air Economizer
Electric Resistance Heat
Fan Systems
Ductwork (existing to remain, altered or new)
Ventilation
Zonal Systems/ Terminal Boxes
Documentation Software: EnergyPro
Compliance ID: EnergyPro-41015-0424-0287
Ronnrt r.onor:atorl· J0)4.04.04 11·OR·41
STATE OF CALIFORNIA
Mechanical Systems
CERTIFICATE OF COMPLIANCE
Project Name: Quidel Redwood Phase 2.2
C. COMPLIANCE RESULTS
CALIFORNIA ENERGY COMMISSIO~
NRCC-MCH-~
!Report Page: (Page 2 of 11)
!Date Prepared: 4/4/2024
Table C will indicate if the project data input into the compliance document is compliant with mechanical requirements. This table is not editable by the user. If this table says "DOES
NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D., or the table indicated as not compliant for guidance.
01 02 03 04 05 06
System Fans/ System Summary Terminal Box
110.1, AND Pumps AND Economizers AND Controls AND Ventilation AND Controls AND
110.2, 140.4{k), 140.4(c), 110.2, 120.2, 120.1, 160.2 140.4(d), 170.2{c)41 140.4(e), 140.4{f), 140.4, 170.2(c) 170.2(c) 170.2{c)4B
170.2{c)
(See Table F) (See Table G) {See Table H) (See Table I) {See Table J) {See Table K)
AND AND Yes AND Yes AND Yes AND Yes AND
Mandatory Measures Compliance (See Table Q for Details)
D. EXCEPTIONAL CONDITIONS
This table is auto-filled with uneditable comments because of selections made or data entered in tables throughout the form.
E. ADDITIONAL REMARKS
This table includes remarks made by the permit applicant to the Authority Having Jurisdiction.
F. HVAC SYSTEM SUMMARY (DRY & WET SYSTEMS)
Space Conditioning System Information
01 02
System Name Quantity
CA Building Energy Efficiency Standards -2022 Nonresidential Compliance
03
System Serving
04
System Status
Generated Date/Time:
Report Version: 2022.0.000
~rhom::a \/.orc:inn • r"O\I ?O'J?n1 n1
07 08 09
Distribution
120.3, AND Cooling Towers
140.4(1), 110.2{e)2 Compliance Results
160.2, 160.3
(See Table L) {See Table M)
Yes AND COMPLIES
COMPLIES
05 06
Space Type Utilizing Recovered Heat
Documentation Software: EnergyPro
Compliance ID: EnergyPro-41015-0424-0287
llonnrt (.;onor::.torl· J0-)4-04.04 11 ·0R·41
STATE OF CALIFORNIA
Mechanical Systems CALIFORNIA ENERGY COMMISSIO~l
CERTIFICATE OF COMPLIANCE NRCC-MCH-E
Project Name: Quidel Redwood Phase 2.2 I Report Page: (Page 3 of 11)
I Date Prepared: 4/4/2024
F. HVAC SYSTEM SUMMARY (DRY & WET SYSTEMS)
Dry System Equipment Sizing (includes air conditioners, condensers, heat pumps, VRF, furnaces and unit heaters and DOAS systems)
01 02 03 04 05 06 07 08 09 10 11
Equipment Sizing per Mechanical Schedule (kBtu/h)
140.4(a&b), 170.2(c)l & 170.2(c}2
Equipment Category per Smallest Size Heating Output2•3 Cooling Output2•3 Load Calculations3•4
Name or Item Tables 110.2, 140.4(a)2 and Equipment Type per Tables 110.2 and Available1 Total
Tag Title 20 140.4(a) and Supp. Total
170.2(c)3aii Sensible Sensible
170.2(c}l Per Design Rated Heating Rated Heating
(kBtu/h} (kBtu/h} Output Per Design (kBtu/h) Load Cooling
(kBtu/h} Load (kBtu/h} (kBtu/h} (kBtu/h)
1 FOOTNOTES: Equipment shall be the smallest size, within the available options of the desired equipment line, necessary to meet the design heating and cooling loads of the building per
140.4(a) and 170.2{c)1. Healthcare facilities are excepted.
2/t is common practice to show rated output capacity on the equipment schedule. Sensible cooling output comes from specification sheet tables.
3 If equipment is heating only, leave cooling output and load blank. If equipment is cooling only, leave heating output and load blank.
4 Authority Having Jurisdiction may ask for load calculations used for compliance per 140.4{b) and 170.2{c).
IG. PUMPS
This section does not apply to this project.
CA Building Energy Efficiency Standards -2022 Nonresidential Compliance
Generated Date/Time:
Report Version: 2022.0.000
c;,rhom:a \/orc:inn· ro\l ")nJ?n1n1
Documentation Software: EnergyPro
Compliance ID: EnergyPro-41015-0424-0287
R<>nnrt (.;pn<>r:>t<>rl • J(IJ4-fM.-fl4 11 ·flSl·41
STATE OF CALIFORNIA
Mechanical Systems CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-~
Project Name: Quidel Redwood Phase 2.2 lReport Page: (Page 4 of 11)
!Date Prepared: 4/4/2024
H. FAN SYSTEMS & AIR ECONOMIZERS
This table is used to demonstrate compliance with prescriptive requirements found in 140.4(c}, 140.4(e}, 140.4(m), 170.2(c}3, and 170.2(c)4A for fan systems. Fan systems serving only
process loads are exempt from these requirements and do not need to be included in Table H.
Serving Not Fan
System FC 1-5 Quantit 1 Fan System New System all other Dwelling Serving System
Name y Status Zoning systems Units Dwelling Airflow
Units {cfm)
01 02 03 04 05 06 07 08
Allowance Fan Water Name Airflow through Fan
Fan Type Qty Component Gauge Compone Allowance or Item Component{%} nt
Tag (w.g) Allowance (watt/cfm)
3
Base Allowance for system serving 1,200 278 spaces <=6 floors away
MERV 13-16 Filter upstream of 1,200 167 SF Supply 1 thermal conditioning equipment
Central Hydronic heating coil 1,200 55
Hydronic/DX cooling coil or heat 1,200 167 pump coil
Supply Fan Base Exhuast/Return/Relief/Transfer Fan Base Fan System
Allowance (kW) Allowance(kW} Allowance (kW)3
1 FOOTNOTES: Fans serving spaces with design background noise goals below NC35
2 Low-turndown single-zone VAV fan system must be capable of and configured to reduce airflow to 50 percent of
design airflow and use no more than 30 percent of the design wattage at that airflow. No more than 10 percent of the
design load served by the equipment shall have fixed loads.
3 Fan system allowance includes fan system base allowance.
4 Filter pressure loss can only be counted once per fan system.
5 Complex Fan System means a fan system that combines a single cabinet fan system with other supply fans, exhaust
fans, or both.
6 Computer room economizers must meet requirements of 140.9{a) and will be documented on the NRCC-PRC-E
document..
CA Building Energy Efficiency Standards -2022 Nonresidential Compliance
Generated Date/Time:
Report Version: 2022.0.000
~rht11m::::. \/~re inn· r&l\l 101101 n1
NA: Special
1,200 Site 44 Economizer OA Elevation filtration
09 10 11
Design
Design
Design Electrical Input Power Motor Electrical Nameplate Method Horsepower Input
Power (kW}
Manufacturer provided 0.73
Fan System Electrical
Output (kW)
Documentation Software: EnergyPro
Compliance ID: EnergyPro-41015-0424-0287
R<>nn rt h <>n<>r:>t<>rl • ')ff)4-04-04 11 ·OR ·41
STATE OF CALIFORNIA
Mechanical Systems CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-~
Project Name: Quidel Redwood Phase 2.2 lReport Page: (Page 5 of 11)
!Date Prepared: 4/4/2024
Fan Energy Index (FEI)
01 02 03
Name or Item Tag FEI Exception FEI
I. SYSTEM CONTROLS
This table is used to demonstrate compliance with mandatory controls in 110.2 and 120.2 and prescriptive controls in 140.4{!} and (n), 170.2(c}40 170.2{c}4L or requirements in
141.0(b}2E 180.2{b)2 for altered space conditioning systems.
01 02 03 04 05 06 07 08 09
Conditioned Thermostats Shut-Off Isolation Supply Air
System Floor Area 110.2(b) & (c)1, 120.2(a) Controls Zone Demand Response Temp. Reset Window Interlocks per System Name Controls 110.12 120.2(b) & Zoning Being Served 160.3(a)2A or 141.0(b)2E & 120.2(e) & 120.2(g) & 160.3(a)28 140.4(f) & 140.4(n) & 170.2(c)4D
(ft2) 180.2(b)2 160.3(a)2D 160.3(a)2F 170.2(c)4D
NA: Altered NA: Single FC 1-5 Single zone <= 25,000 ft2 EMCS per EMCS Included NA: No operable windows
141.0(b)2E Zone
1FOOTNOTES: Gravity gas wall heaters, gravity floor heaters, gravity room heaters, non-central electric heaters, fireplaces or decorative gas appliances, wood stoves are not required to
have setback thermostats.
J. VENTILATION AND INDOOR AIR QUALITY
This table is used to demonstrate compliance with mandatory ventilation requirements in 120.1120.2{e)38 140.4(p) and 140.4{q) for all nonresidential and hotel/motel and
d:t24refnolink/]160.2, 160.3{a}30, 170.2(a}4N, 170.2{a}40 for high-rise residential occupancies. For alterations, only ventilation systems being altered within the scope of the permit
application need to be documented in this table. In lieu of this table, the required outdoor ventilation rates and airflows may be shown on the plans or the calculations can be presented
in a spreadsheet.
01 □ Check the box if the project is showing ventilation calculations on the plans, or attaching the calculations instead of completing this table.
181 Check this box if the project included Nonresidential, Hotel/Motel Spaces or Multifamily Common Use Spaces
02 □
03 □ Check the box if the project is using natural ventilation in any nonresidential or hotel/motel spaces to meet required ventilation rates per 120.l(c)2.
Nonresidential and Hotel/ Motel Multifamily Common Use Ventilation Systems
CA Building Energy Efficiency Standards -2022 Nonresidential Compliance
Generated Date/Time:
Report Version: 2022.0.000
"rh,:am::. V,:arc:inn• r-ii:au ')n??n1n1
Documentation Software: EnergyPro
Compliance ID: EnergyPro-41015-0424-0287
Ronnrt rsonor:,torl• JnJ4_n4_1\4 11 •nR•41
STATE OF CALIFORNIA
Mechanical Systems CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-f
Project Name: Quidel Redwood Phase 2.2 !Report Page: (Page 6 of 1i)
!Date Prepared: 4/4/2024
J. VENTILATION AND INDOOR AIR QUALITY
04 05 06 07
System Design OA CFM Air Filtration per 120.l(c) 141.0(b)2 and
System Name (e) AH-1 92 System Design 0 160.2(c)212
Airflow1 Transfer Air CFM Provided
08 09 10 11 12 13 14 15 16
Mechanical Ventilation Required per 120.l(c)33 & 160.2(c)3 Exh. Vent per 120.l(c)4 &
160.2(c)4 DCV or Sensor Controls per 120.l(d)3, Space Name Conditioned # of Shower Required 120.l(d)S, and 120.l(e)36 160.2(c)5D or Item Tag
Occupancy Type4 Floor Area heads/ #of MinOA Required Provided per Design 160.2(c)5E 160.2(c)SD
(ft2) toilets peoples CFM Min CFM CFM
DCV NA: Not required per
§120.l(d}3 VAV-1-7 All others 260 39 0 0
0cc Sensor NA: Not required
space type
DCV NA: Not required per
VAV-1-10 All others 350 52.5 0 0 §120.l(d}3
0cc Sensor NA: Not required
space type
17 Total System Required Min OA CFM 92 18 Ventilation for this System Complies? Yes
04 OS 06
System Design OA CFM System Design System Name (e) AH-9 43 0 Airflow1 Transfer Air CFM
08 09 10 11 12 13 14 15
Mechanical Ventilation Required per 120.l(c)33 & 160.2(c)3 Exh. Vent per 120.l(c)4 &
160.2(c)4
Space Name Conditioned # of Shower or Item Tag
Occupancy Type4 Floor Area heads/
(ft2) toilets
CA Building Energy Efficiency Standards -2022 Nonresidential Compliance
Required # of Required MinOA peoples CFM Min CFM
Generated Date/Time:
Report Version: 2022.0.000
<:rh-,m:, \/"'rcinn· '"" ?0??0101
Provided per Design
CFM
07
Air Filtration per 120.l(c) 141.0(b)2 and
160.2(c)212
Provided
16
DCV or Sensor Controls per 120.l(d)3,
120.l(d)5, and 120.l(e)36 160.2(c)SD
160.2(c)5E 160.2(c)5D
Documentation Software: EnergyPro
Compliance ID: EnergyPro-41015-0424-0287
R-,nnrt r.-,n-,,:,t-,rl· ?0?4-04.0411 ·f\l:1·41
STATE OF CALIFORNIA
Mechanical Systems CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-~
Project Name: Quidel Redwood Phase 2.2 !Report Page: (Page 7 of 11)
!Date Prepared: 4/4/2024
J. VENTILATION AND INDOOR AIR QUALITY
DCV NA: Not required per
§120.l{dl3
VAV-9-7 All others 286 42.9 0 0
0cc Sensor NA: Not required
space type
17 Total System Required Min OA CFM 43 18 Ventilation for this System Complies? Yes
04 05 06 07
System Design OA CFM System Design
Air Filtration per 120.l(c) 141.0(b)2 and
System Name FC 1-5 120 0 160.2(c)212
Airflow1 Transfer Air CFM Provided
08 09 10 11 12 13 14 15 16
Mechanical Ventilation Required per 120.l(c)33 & 160.2(c)3 Exh. Vent per 120.l(c}4 &
160.2(c)4 DCV or Sensor Controls per 120.l(d)3, Space Name Conditioned # of Shower Required 120.l(d)5, and 120.l(e)36 160.2(c)5D or Item Tag # of Required Provided per Design Occupancy Type4 Floor Area heads/ MinOA 160.2(c}5E 160.2(c}5D
(ft2} toilets people5
CFM MinCFM CFM
DCV NA: Not required per
§120.l{d}3
Hallway 127 Corridor 800 120 0 0
0cc Sensor NA: Not required
space type
17 Total System Required Min OA CFM 120 18 Ventilation for this System Complies? Yes
1 FOOTNOTES: System CFM should include both mechanical and natural ventilation for the zone/system
2 Air filtration requirements apply to the following three system types per 120.l{c)lA: space conditioning systems utilizing ducts to supply air to occupiable space; supply-only ventilation
systems providing outside air to occupiable space; supply side of balanced ventilation systems including heat recovery and energy recovery ventilation systems providing outside air to
occupiable space.
3 Uniform Mechanical Code may have more stringent ventilation requirements; the most stringent code requirement takes precedence.
4 See Standards Tables 120.1-A and 120.1-B.
s For lecture halls with fixed seating, the expected number of occupants shall be determined in accordance with the California Building Code.
6 120.2(e}3 requires systems serving rooms that are required by 130.l(c) to have lighting occupancy sensing controls to also have occupancy sensing zone controls for ventilation.
Examples of spaces which require lighting occupancy sensors include offices 250ft2 or smaller, multipurpose rooms less than 1,000 ft2, classrooms, conference rooms, restrooms, aisles
and open areas in warehouses, library book stack aisles, corridors, stairwells, parking garages, and loading and unloading zones, unless excepted by 130.l{c).
CA Building Energy Efficiency Standards -2022 Nonresidential Compliance
Generated Date/Time:
Report Version: 2022.0.000
~rhpm ::::1 \lon:inn· rP\I ,n,,n1 n1
Documentation Software: EnergyPro
Compliance ID: EnergyPro-41015-0424-0287
R<>n,...rt r.<>n<>r.>t<>rl· ,n,4-04.04 11 ·0R·41
STATE OF CALIFORNIA
Mechanical Systems CALIFORNIA ENERGY COMMISSIOt-.
CERTIFICATE OF COMPLIANCE NRCC-MCH-~
Project Name: Quidel Redwood Phase 2.2 lReport Page: (Page 8 of 11)
lDate Prepared: 4/4/2024
K. TERMINAL BOX CONTROLS
This table is used to demonstrate compliance with prescriptive zone control requirements in 140.4{d) & 170.2(c)4B.
01 02 03 04 05 06 07 08 09 10 11 12
Design Deadband Compliance Reheated, Recooled, Mixed Air Compliance
Peak Primary Reheated 30% of Peak Max 1st Stage 2nd Stage
Zone/System/VAV Box Zonal Control Strategy per Recooled Outside 50% of Peak Modulates from
Name or Item Tag 140.4(d) Primary Air in Mixed Air Primary Deadband Primary Modulates <=95 DB Flow to
Complies
Airflow Deadband Airflow Airflow °F and Maintains
CFM CFM Airflow CFM CFM CFM Airflow DB Rate? Heating Max
CFM Flow?
VAV-1-7 VAV with DDC @ zone 1200 240 400 39 240 241 600 Yes Yes Yes
VAV-1-10 VAV with DDC @ zone 1500 300 500 52.5 300 301 750 Yes Yes Yes
VAV-9-7 VAV with DDC @ zone 500 100 230 42.9 100 101 250 Yes Yes Yes
L. DISTRIBUTION (DUCTWORK and PIPING)
This table is used to show compliance with mandatory pipe insulation requirements found in 120.3 and mandatory requirements found in 120.4{g) for duct sealing.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to
01 D weather shall be installed with a cover suitable for outdoor service. Insulation covering chilled water piping and refrigerant suction piping located
outside the conditioned space shall have a Class I or Class II vapor retarder. All penetrations and joints of which shall be sealed.
Duct Leakage Testing
The answers to the questions below apply to the following duct systems: I FC 1-5 I NR/ Common Use: Duct leakage testing shall not exceed 6% per I No NA7.5.3 required for these systems?
CA Building Energy Efficiency Standards -2022 Nonresidential Compliance
Generated Date/Time:
Report Version: 2022.0.000
<;.rh~m=-\/~rc:inn• r~\/ ,n??n1n1
Documentation Software: EnergyPro
Compliance ID: EnergyPro-41015-0424-0287
Ronnrt r.on<>r:>t<>ri· 1ff)4A)4.1)4 11 ·0R·41
STATE OF CALIFORNIA
Mechanical Systems CALIFORNIA ENERGY COMMISSIOt.
CERTIFICATE OF COMPLIANCE NRCC-MCH-~
Project Name: Quidel Redwood Phase 2.2 I Report Page: (Page 9 of 1:!)
!Date Prepared: 4/4/2024
L. DISTRIBUTION (DUCTWORK and PIPING)
Dwelling Units: Total duct leakage of duct system shall not exceed 12%
or duct system to outside shall not exceed 6% per RA3.1.4 required for No
systems?
Duct leakage testing per CMC Section 603.10.1 required for these No systems?
11 No The scope of the project includes only duct systems serving healthcare facilities
12 Yes Duct system provides conditioned air to an occupiable space for a constant volume, single zone, space-conditioning system.
13 Yes The space conditioning system serves less than 5,000 ft2 of conditioned floor area.
14 No The combined surface area of the ducts is more than 25% of the total surface area of the entire duct system:
15 The scope of the project includes extending an existing duct system, which is constructed, insulated or sealed with asbestos.
16 No The scope of the project includes an existing duct system that is documented to have been previously sealed as confirmed through field verification
and diagnostic testing in accordance with procedures in the Reference Nonresidential Appendix NA2.
17 All Ductwork and plenums with pressure class ratings shall be constructed to Seal Class A
18 All ductwork is an extension of an existing duct system
19 Ductwork serving individual dwelling unit
20 < 25 ft of new or replacement space conditioning ducts installed
21 R-4.2 Duct Insulation R-value
22
23
M. COOLING TOWERS
This section does not apply to this project.
CA Building Energy Efficiency Standards -2022 Nonresidential Compliance
Generated Date/Time:
Report Version: 2022.0.000
<:.rhtiom:. \/orc:inn· r-=s\l ?0?101 n1
Documentation Software: EnergyPro
Compliance ID: EnergyPro-41015-0424-0287
R<>nnrt r.<>n<>r::>t<>ri· ?n?4-n4-n4 11 •nR-41
STATE OF CALIFORNIA
Mechanical Systems CALIFORNIA ENERGY COMMISSION'
CERTIFICATE OF COMPLIANCE NRCC-MCH-li
Project Name: Quidel Redwood Phase 2.2 !Report Page: (Page 10 of li)
!Date Prepared: 4/4/2024
N. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION
Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E Additional Remarks.
These documents must be provided to the building inspector during construction and can be found on line at
https://www.energy.ca.gov/title24/2019standards/2019 compliance documents/Nonresidential Documents/NRCI/
Form/fitle
NRCI-MCH-01-E -Must be submitted for all buildings
0. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE
Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E Additional Remarks.
These documents must be provided to the building inspector during construction and can be found online at
https ://www.energy.ca. gov /title 24/2019standards/2019 _compliance_ documents/Nonresidential_ Documents/NRCA/
Form/Title Systems/Spaces To Be Field
Verified
NRCA-MCH-02-A -Outdoor Air must be submitted for all newly installed HVAC units. Note: MCH-02-A can be performed in conjunction with MCH-07-A Daikin BCHD0101;
Supply Fan VFD Acceptance (if applicable) since testing activities overlap.
NRCA-MCH-11-A Automatic Demand Shed Controls
NRCA-MCH-18-A Energy Management Control Systems
P. DECLARATION OF REQUIRED CERTIFICATES OF VERIFICATION
There are no NRCV forms required for this project.
Q. MANDATORY MEASURES DOCUMENTATION LOCATION
This table is used to indicate where mandatory measures are documented in the plan set or construction documentation.
01
Compliance with Mandatory Measures documented through MCH
Mandatory Measures Note Block
CA Building Energy Efficiency Standards -2022 Nonresidential Compliance
Yes
Generated Date/Time:
Report Version: 2022.0.000
<;.rhom::. \/orc:inn• rt':lu ,n1,n1n1
Daikin BCHD0101;
Daikin BCHD0101;
02
Plan sheet or construction document location
M-Sheets
Documentation Software: EnergyPro
Compliance ID: EnergyPro-41015-0424-0287
R<>nnrt r.<>n<>r:>t<>n· JnJ,1_n4_n4 11 •nR•41
STATE OF CALIFORNIA
Mechanical Systems
CERTIFICATE OF COMPLIANCE
Project Name: Quidel Redwood Phase 2.2 !Report Page:
Project Address: 2285 Rutherford RoadlDate Prepared:
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
I certify that this Certificate of Compliance documentation is accurate and complete. \ .~ \
Documentation Author Name: Documentation Author Signatur~ ~ \ 1.-1-....
Company: Signature Date: J
J&R Engineering & Consulting, Inc. 2024-04-04
Address: CEA/ HERS Certification Identification (if applicable):
City/State/Zip: Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
4-
• CALIFORNIA ENERGY COMM ISSIQij
NRCC-MCH~
(Page 11 of 1!)
4/4/2024
2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer)
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements
of Title 24, Part 1 and Part 6 of the C31ifornia Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations,
plans and specifications submitted to the enforcement agency for approval with this building permit application.
s. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the doi;umentatJ.o, the builder provides to the building owner at occupancy.
Responsible Designer Name:
Scott Johnson
Company:
J&R Engineering & Consulting, Inc.
Address:
16769 Bernardo Center Drive, Suite 1 #768
City/State/Zip:
San Diego CA 92128
CA Building Energy Efficiency Standards· 2022 Nonresidential Compliance
Responsible Designer-".~l\ ....
Date Signed:
2024-04-04
License:
M32413
Phone:
619-823-2909
Generated Date/Time:
Report Version: 2022.0.000
C::rht::1m::1 \/,:1rcinn• riP\I 1nr>n1 n1
J
Documentation Software: EnergyPro
Compliance ID: EnergyPro-41015-0424-0287
Ronnr-t r.onor::iton· ,n-)4.n4.n4 11 •n~•41
Hazardous Materials Questionnaire
County of San Diego, Department of Environmental Health and Quality
PO Box 129261, San Diego, CA 92112-9261
(858) 505-6700 (800) 253-9933 www.sdcdehq.org
Business Name
QUIDELORTHO
Project Address
2285 RUTHERFORD RD
Applicant
Sarah A McAllister
Business Contact
JULIO GIANNOTTI
City
CARLSBAD
State
CA
Applicant E-Mail
sam@mcfarlanearchitects.com
Record ID #: DEH2002-HUPFP-132942
Plan Check#: DEH2024-HHMBP-014235
Telephone# Plan File#
(619) 495-1918
Zip Code
92008-8815
Applicant Telephone#
(858) 495-1918
APN#
212-062-08-00
The following questions represent the fac111ty's activities, NOT the specific project description.
PART J· EIRE DEPARTMENT -HAZARDOUS METERJALS PIYIS!ON· OCCUPANCY CLASSIFICATION: {Not required for projects within the City of San Diego.)
Indicate by selecting the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are selected, Applicant must
contact the Fire Protection Agency with jurisdiction prior to plan submittal.
Occupancy Rating: B, F1, S1 Fac111ty's Square Footage {including proposed project): 199687
D Explosive or Blasting Agents D Organic Peroxides D Water Reactives li!l Corrosives
li!I Compressed Gases 00 Oxidizers
Pyrophorics
00 Cryogenics D 01her Health Hazards
li!I
D
Flammable/Combustible Liquids
Flammable Solids
D
00 Unstable Reactives
Ii!]
D
Highly Toxic or Toxic Materials
Radioactives
D None of These
PART II: SAN DIEGO COUNTY DEPARTMENT Of ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS PIYISJON IHMP): If the answer to any of the questions Is
yes, applicant must contact the County of San Diego Hazardous Materials Division, in person at 5500 Overland Ave., Suite 110, San Diego, CA 92123, or by phone at (858)
505-6700 prior to issuance of a building permit. FEES ARE REQUIRED.
Project Completion Date: 9/30/2024
YES
1. li!I
2. li!I
3. Ii!]
4. D
5. D
6. D
7. D
8. Ii!!
NO
D
D
D
D
l!l
l!l
li!I
D
Is your business listed on the reverse side of this form? (check all that apply).
Will your business dispose of Hazardous Substances or Medical Waste in any amount?
Will your business store or handle Hazardous Substances in quantities equal to or greater than
55 gallons, 500 pounds, or 200 cubic feet?
Will your business handle carcinogens or reproductive toxins in any quantity?
WIii your business use an existing, or install an underground storage tank?
Will your business store or handle Regulated Substances {CalARP)?
Will your business use or install a Hazardous Waste Tank System {Title 22, Article 10)?
Will your business store petroleum in tanks or containers at your facility with a total storage capacity
equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act).
D
D
D
CalARP Exempt
CalARP Required
CalARP Complete
Review Date:
PART m· SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT CAPCD): If the answer to Question #1 is 'Yes' and the answer to Question #2 Is 'No', the applicant
must contact the APCD prior to the issuance of a building or demolition permit. If any answer to Questions #3, #4, or #5 is 'Yes', the applicant must contact the APCD prior to
the issuance of a building or demolition permit. If the answer to Question #3 or #4 Is 'Yes', the applicant may need to submit an asbestos notification form to the APCD at
least 1 O working days prior to commencing demolition or renovation {some residential projects may be exempt from the notification requirements). Contact the APCD at
10124 Old Grove Road, San Diego, CA 92131 or telephone (858) 586-2600 for more information.
YES NO
1. l!l D
2. lii1 D
3. D Ii!!
Will any existing building materials be disturbed as part of this project? (If the answer is 'Yes', an asbestos survey may be required.)
Has a survey been performed to determine the presence of asbestos containing materials?
Will the project involve handling or disturbance of any asbestos containing materials?
4. D Ii!!
5. D lii1
Will the project involve the removal of any load supporting structural member?
Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD
factsheet at http://Www.sdapcd.org/info/facts/permits.pdf (ANSWER ONLY IF QUESTION 5 IS 'YES') Will the subject facility be located within 1,000 feet of the outer boundary of a school {K through 12)? Search
the California School Directory at http://Www.cde.ca.gov/re/sd/ for public and private schools or contact the appropriate school district. 6. D 18}
Briefly describe business activities: Briefly describe proposed project:
IN VITRO DIAGNOSITICS COMPANY SPECIALIZING IN RESPIRATORY HEALTH Interior tenant Improvement, Including minor demolition, new walls, doors,
DIAGNOSTICS, TRANSFUSION MEDICINE, IMMUNOASSAY & MOLECULAR ce111ngs, finishes, plumbing fixtures & lighting. Modifications to MEP as
I declare under penalty of perjury that to the best of my knowledge and belief, the responses made herein are true and correct. l!l; Fees Acknowledged: li!1
SARAH MCALLISTER/ MCFARLANE ARCHITECTS
Name of Owner or Authorized Agent
FOR OFFICIAL USE ONLY
FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:
BY:
EXEMPT OR NO FURTHER INFORMATION
REQUIRED
COUNTY-HMO•
~ oFSN;,~
AEVICVYtO
M. Martinez
SIQljl(TIJAf
4/5/2024
OAT! .... ...,.
APCD
O~ CONr,i'? ~;(," o< .;:;-o,.. R REVIEWED B't ~
a: M. Fregoso !? :i ~
RELEASED FOR BUILDING PERMIT BUT NOT FOR
OCCUPANCY
COUNTY-HMO APCD
4/3/2024
Date
DATE: __________ _
RELEASED FOR OCCUPANCY
COUNTY-HMO APCD
•A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply.
OEHQ_HMO_HMBP _Questionnaire v 2.0 (8/2021)
Printed on: 4/10/2024 @ 2:57 PM
Building Permit Finaled
Revision Permit
Print Date: 03/25/2025
Job Address:
Permit No:
Status:
{city of
Carlsbad
PREV2024-0109
Closed -Finaled
Permit Type:
2285 RUTHERFORD RD,
BLDG-Permit Revision
2120620800
CARLSBAD, CA 92008-8815
Work Class: Commercial Permit Revision
Parcel#:
Valuation:
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition:
Sprinkled:
Project Title:
Track#:
$0.00 Lot#:
Project#:
Plan#:
Construction Type:
Orig. Plan Check#:
Plan Check#:
Description: QUIDELORTHO: RELOCATE SINK ON 1ST FLOOR.
Applicant :
MCFARLANE ARCHITECTS
SARAH MCALLISTER
6256 GREENWICH DR, # STE 500
SAN DIEGO, CA 92122-5946
FEE
BUILDING PLAN CHECK REVISION ADMIN FEE
THIRD PARTY REVIEW -Consultant Cost (BLDG)
Total Fees: $155.00 Total Payments To Date:
Building Division
$155.00
Applied: 05/31/2024
Issued: 06/11/2024
Finaled Close Out: 03/25/2025
Final Inspection:
INSPECTOR:
Contractor:
JIM LEEK BUILDERS INC
1687 LOTUS LN
EL CAJON, CA 92021-3716
(858) 735-8878
Balance Due:
AMOUN:r
$35.00
$120.00
$0.00
Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
{ City of
Carlsbad
PLAN CHECK REVISION OR
DEFERRED SUBMITTAL
APPLICATION
8-15
I by City Sta.ff!
Development Services
Building Division
1635 Faraday Avenue
442-339-2719
www.carlsbadca.gov
. . CBC2024-0334 Ong1nal Plan Check Number _______ L.:.P..:.:la;:.:.n.:.R~e;.:v:.:,;is:.:,:io:::.:n.:..:..:N~u.:.:,m.:.:;b:.:;e.:.r ~;;;;;!;;;;;;~~~;;;;;;;;;;~;;.;;;;;;;;;;;;;;;;1
Project Address 2285 RUTHERFORD ROAD CARLSBAD, CA 92008
G IS f R --vo f d s b •tt I Dry Room Insulated Metal Panel Assembly enera cope o ev1S1on e erre u mr a: __________________ _
Shop Drawings -Deferred Submittal
CONTACT INFORMATION:
Name William Reyes Phone 760-415-2234 ________ Fa . ._ ________ _
Address _5_0_5_1 _A_v_e_n_id_a_E_n_ci_n_a_s ________ City Carlsbad Z. 92008 IP -----
Email Address william@prevostconstruction.com
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that
person.
1 . Elements revised: Iii Plans D Calculations D Soils D Energy D Other
2. 3.
Describe revisions in detail List page{s) where each
revision is shown
Deferred Submittal of Dry Room Insulated Metal Panels
4. Does this revision, in any way, alter the exterior of the project?
5. Does this revision add ANY new floor area(s)?
6. Does this revision affect any fire related issues?
7. Is this a full set replacement (all sheets)?
//;ft'aM Re-aM g Signature ______ ----'---tf_ ~ -________ _
Oves 0No
Oves ({]No
Oves [{]No
Oves [{]No
12-24-24 Date
1635 Faraday Avenue, Carlsbad, CA 92008 fti: 7 60-602-2719 ~: 7 60-602-8558 Email: buildini.i@carisbadca.gov
www.cadsbadca.gov
February 18, 2025
City of Carlsbad
Community Development Department -Building Division
1635 Faraday Ave.
Carlsbad, CA 92008
Plan Review: Revision TI Quidelortho
Address: 2285 Rutherford Rd
Applicant Name: William Reyes
Applicant Email: william@prevostconstruction.com
OCCUPANCY AND BUILDING SUMMARY:
Occupancy Groups: S-1 , B
Occupant Load: 1,006 (Total Building)
Type of Construction: II1-B
Sprinklers: Yes
Stories: I
Area of Work (sq. ft.): I ,218 sq. ft.
The plans have been reviewed for coordination with the pennit application.
Valuation: Confirmed
Scope of Work: Confirmed
Floor Area: Confirmed
Notes: NIA
Attn: Building & Safety Department,
True North
COMPLIANCE SERV ICES
City of Carlsbad -FINAL REVIEW
City Permit No: PREV2024-0245
True North No.: 24-018-1176
True North Compliance Services, Inc. has completed the final review of the following documents for the project
referenced above on behalf of the City of Carlsbad:
1. Drawings: One (1) copy dated January 19, 2025, by Gary Bosz.
The 2022 California Building, Mechanical, Plumbing, and Electrical Codes (i.e., 2021 IBC, UMC, UPC, and 2020
NEC, as amended by the State of California), 2022 California Green Building Standards Code, 2022 California
Existing Building Code, and 2022 California Energy Code, as applicable, were used as the basis of our review.
Please note that our review has been completed and we have no further comments, however, we bring the
following to your attention:
I. This project is Hourly. Please charge the applicant the following hours of plan review.
True North Compliance Services, Inc.
8369 Vickers Street, Suite 207, San Diego, CA 92111
T / 562. 733.8030
Review No. Hourly Rate Hours Total
1st Review $120.00 4 $480.00
2nd Review $120.00 2 $240.00
3rd Review $120.00 1.5 $180.00
Total $900
We have enclosed the above noted documents bearing our review stamps for your use. Please call if you have any
questions or if we can be of further assistance.
Sincerely,
True North Compliance Services
Review By: Mulham Hweidi -Plan Review Engineer
Quality Review By: Alaa Atassi Senior Plan Review Engineer
Building Permit Finaled
Revision Permit
Print Date: 03/25/2025
Job Address: 2285 RUTHERFORD RD, CARLSBAD, CA 92008-8815
Permit No:
Status:
{city of
Carlsbad
PREV2024-0135
Closed -Finaled
Permit Type: BLDG-Permit Revision Work Class: Commercial Permit Revision
Parcel#:
Valuation:
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition:
Sprinkled:
Project Title:
2120620800 Track #:
$67,092.96 Lot#:
Project#:
Plan#:
Construction Type:
Orig. Plan Check #: CBC2024-0103
Plan Check#:
Applied: 07/03/2024
Issued: 07/24/2024
Finaled Close Out: 03/25/2025
Final Inspection:
INSPECTOR:
Description: QUIDELORTHO: RELOCATE ELECTRICAL PANELS, DOOR INFILL, RELOCATE FISHBOWL ROOM, UTILITIES AS REQUIRED.
Applicant:
M CFARLANE ARCHITECTS
SARAH MCALLISTER
6256 GREENWICH DR, # STE 500
SAN DIEGO, CA 92122-5946
FEE
BUILDING PLAN CHECK REVISION ADMIN FEE
FIRE Plan Review (per hr -Regular Office Hours)
THIRD PARTY REVIEW -Consultant Cost (BLDG)
Total Fees : $325.00 Total Payments To Date:
Building Division
$325.00
Contractor :
JIM LEEK BUILDERS INC
1687 LOTUS LN
EL CAJON, CA 92021-3716
(858) 735-8878
Balance Due:
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
AMOUNT
$35.00
$170.00
$120.00
$0.00
Page 1 of 1
.
C Cityof
PLAN CHECK REVISION OR Develo~ment Services
DEFERRED SUBMITTAL Building Division
Carlsbad APPLICATION 1635 Faraday Avenue
442-339-2719
B-15 www.carlsbadca.gov
I by City Staff! _
Plan Revision Number W,\3) 7 1)24 -0 I 3.'1 Original Plan Check Number
CBC2024-0103
P . dd 2285 RUTHERFORD ROAD, CARLSBAD, CA. 92008 roJect A ress -----------------------------------
RELOCATE ELECTRICAL PANELS, DOOR INFILL, RELOCATE FISHBOWL
General Scope of Revision/Deferred Submittal: _;__R;_:cO__;:_O_;_;M.:..., U::.;T..c..:IL'-'-IT__;IE=-=S--A=S __ R_;,::E:..:;:Qc.:;.U_;__IR=Ec:...D''-------------
CONTACT INFORMATION:
SARAH MCALLISTER/ MCFARLANE 619_316_7034 N/A
Name ARCHITECTS Phone Fa >-------------
6256 GREENWICH DRIVE, SUITE 500 Ci·ty SAN DIEGO Address _____________________ _ CA Zip _____ _
E sam@mcfarlanearchitects.com
mail Address -----------------------------------
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that
person.
1 . Elements revised: ~ Plans D Calculations D Soils D Energy D Other
2.
Describe revisions in detail
RELOCATE ELECTRICAL PANELS FROM 2ND FLOOR FREEZER FARM TO 2ND FLOOR MEZZANINE, REMOVE
DOOR & FRAME@ 1 ST LEVEL AND INFILL WALL, PROVIDE ELECTRICAL/ MECHANICAL@ 1 ST LEVEL SWAB
MANUFACTURING ROOM FOR TENANT EQUIPMENT, ELIMINATE JISHUKEN ROOM 111 B@ 1ST LEVEL DRY
ROOM, RELOCATE FISH BOWL ROOM 111A@ 1ST LEVEL DRY ROOM, ASSOCIATED STRUCTURAL,
MECHANICAL AND ELECTRICAL AS REQUIRED.
4. Does this revision, in any way, alter the exterior of the project?
5. Does this revision add ANY new floor area(s)?
6. Does this revision affect any fire related issues?
OYes
OYes
OYes
OYes
3.
List page(s) w here each
revision is shown
CS 100, A001 , A210, A211,
A212, A213, A214, A610,
A611, A612, A950, S211 ,
S220, P111D, P111, P112,
E0.03, E211, E213, E221
~No
~No
ll]No
~No 7. _is this a full set repla~ent fa~r,:
..@'.S'S1gnature ~. ~ ~ .. ~~ Date 06-28-2024
1635 Faraday Avenue. Carlsbad. CA 92008 f.11: 760-602-2719 w : 760-602-8558 Emajl: building@carlsbadca.goy
www.carlsbadca.gov
True North
COMPLIANCE SERVICES
July 11, 2024
City of Carlsbad
Community Development Department -Building Division
1635 Faraday Ave.
City of Carlsbad -FINAL REVIEW
City Penn it No: PREV2024-01 3 5
True North No.: 24-018-583
Carlsbad, CA 92008
Plan Review: Revision TI Quidelortho
Address: 2285 Rutherford Road
Applicant Name: Sarah McAllister/McFarlane Architects
Applicant Email: sam@mcfarlanearchitects.com
OCCUPANCY AND BUILDING SUMMARY:
Occupancy Groups: 8/F I /S-1
Occupant Load: 1,508
Type of Construction: III-A
Sprinklers: Yes
Stories: 2
Area of Work (sq. ft.): 1,164 sq. ft.
The plans have been reviewed for coordination with the permit application.
Valuation: Confirmed
Scope of Work: Confinned
Floor Area: Confirmed
Attn: Building & Safety Department,
True North Compliance Services, Inc. has completed the final review of the following documents for the project
referenced above on behalf of the City of Carlsbad:
I.
2.
Drawings: One (1) copy dated June 28, 2024, by McFarlane Architects.
Structural Calculations: One (I) copy dated July 3, 2024, by KPFF Project.
The 2022 California Building, Mechanical, Plumbing, and Electrical Codes (i.e., 2021 IBC, UMC, UPC, and 2020
NEC, as amended by the State of California), 2022 California Green Building Standards Code, 2022 California
Existing Building Code, and 2022 California Energy Code, as applicable, were used as the basis of our review.
Please note that our review has been completed and we have no further comments, however, we bring the
following to your attention:
l. This project is Hourly. Please charge the applicant the following hours of plan review.
True North Compliance Services, Inc.
8369 Vickers Street, Suite 207, San Diego, CA 92111
T / 562.733.8030
Review No. Hourly Rate Hours Total
1st Review $120.00 1 $120
Total $120
We have enclosed the above noted documents bearing our review stamps for your use. Please call if you have any
questions or if we can be of further assistance.
Sincerely,
True North Compliance Services
Review By: Mohammad Afaneh -Plan Review Engineer
Quality Review By: Areli Sanchez -Plan Review Engineer
, .. ~ ii
NOVA Services
NOVA Services, Inc. -San Diego
4373 Viewridge Avenue, Suite B
San Diego, CA 92123
Phone: 858-292-7575
Daily Field Report
Client:
Quidel Corporation
6675 Summer Ridge Rd
San Diego, CA 92121
Project:
1024114 2285 Rutherford Road
2285 Rutherford Road
Carlsbad, CA 92008
Date: 1 0/23/2024
Time Arrived: 13:30
General Contractor: JLB
Time Departed: 15:30 Hours: 2.00 Lunch Period (minutes): 0
Permit#: CBC-2024-0103 Jurisdiction: Carlsbad
Inspector/Technician: Healy, Jordan Certification #:
City of San Diego #1523, ICC #10277105, ACI #02187998
Reference Documents: Approved plans.
Type of Inspection: Post Installed Anchors
Work Inspected:
Arrived onsite as Nova representative for post installed anchor inspection at interior, level 1 Lab room floor.
Nova inspected hardware to be used, (8) L-brackets and (8) Hilti KH-EZ 1/4" x 3" concrete anchor. Referring to SSK-25 anchorage
details and notes provided. Nova observed hole diameter (1/4") hole depth (3.25") cleanliness was acquired via shop vacuum and
compressed air. Hardware was installed in accordance with approved documents.
No issues noted. Work complete.
Tests Performed on Site: NIA
The work WAS inspected in accordance with the requirements of the approved documents.
The work inspected MET the requirements of the approved documents.
Material Sampling: N/A
Reinspections: 0 Yes ~ No
Page 1 of 3
• NOVA Services
NOVA Services, Inc. • San Diego
4373 Viewridge Avenue, Suite B
San Diego, CA 92123
Phone: 858-292-7575
Daily Field Report
Client:
Quidel Corporation
6675 Summer Ridge Rd
San Diego, CA 92121
Drilling holes
Project:
1024114
2285 Rutherford Road
2285 Rutherford Road
Cansbad, CA 92008
Page 2 of 3
• NOVA Services
NOVA Services, Inc. • San Diego
4373 Viewridge Avenue, Suite B
San Diego, CA 92123
Phone: 858-292-7575
Work complete
I
Daily Field Report
Client
Quidel Corporation
6875 Summer Ridge Rd
San Diego, CA 92121
Project:
1024114
2285 Rutherford Road
2285 Rutherford Road
Carlsbad, CA 92008
Installing anchor bolt
Signed by:
Jordan Healy
10/24/2024
Page3 of 3
• NOVA Services
NOVA Services, Inc. • San Diego
4373 Viewridge Avenue, Suite B
San Diego, CA 92123
Phone: 858-292-7575
Dat.e: 08/05/2024
Daily Field Report Soils
Client:
Quldel Corporation
6675 Sunvner Ridge Rd
San Diego, CA 92121
Project:
1024114
2285 Rutherford Road
2285 Rutherford Road
Car1sbad, CA 92008
Time Arrived: 07:30
Permit #: CBC-2024-0103
General Contractor: JLB
Time Departed: 09:30 Hours: 2.00 Lunch Period (minutes): 0
Jurisdiction: City of Carlsbad
Inspector/Technician: Meza, Coral
Reference Documents: Plumbing Plans, approved plans.
Type of Inspection: Soils / Compaction
Work Inspected: Client informed technician that no services were requested .
The work inspected MET the requirements of the approved documents.
Material Sampling: N/A
Relnspectlons Performed Today: D Yes ~ No
Further Relnspections Required: D Yes~ No
Signed by:
Coral Meza
08/05/2024
Page 1 of 1
,,.
,,.-...._
-NOVA Services
NOVA Services, Inc. • San Diego
4373 Vlewrtdge Avenue, Suite B
San Diego, CA 92123
Phone: 858-292-7575
Date: 07/20/2024
Client:
Quldel Corporation
6675 Summer Ridge Rd
San Diego, CA 92121
Project:
1024114
2285 Rutherford Road
2285 Rutherford Road
Carlsbad, CA 92008
Time Arrived: 10:30
General Contractor: JLB
Time Departed: 12:30 Hows: 2.00 Lunch Period (minutes): 0
Permit#: CBC-2024-0103
Inspector/Technician: McGinty, Patrick
Reference Documents: Plumbing Plans, approved plans.
Type of Inspection: Solis I Compaction
Work Inspected:
Jurisdiction: City of Carlsbad
Arrived on site as requested. Discussed earthwork operations with JLB site supervisor.
Work to be inspected consisted of checking remediation efforts for shading sand placement and observation of native fill placement for
plumbing trench located at interior of building.
Shading sand section of pipe were approximately 3" and 611 deep. Native fill section is approximately 18".
Contractor performed moisture conditioning of fill ( sand and native) and placed In appropriate sized lifts.
Compaction efforts on lifts were made by means of a mechanical tamper.
Lifts and subgrade probed firm and unyielding. In-place moisture-density tests performed are pending lab results of the sample
collected 7/19/24.
Tests Performed on Site: Manual probing, and in-place moisture-density testing.
The work WAS inspected in accordance with the requirements of the approved documents.
The work inspected is pending lab results.
Material Sampling: N/A
Relnspections Performed Today: D Yes~ No
Further Relnspections Required: D Yes ~ No
Page 1 of 2
Ill
NOVA Services
NOVA Services, Inc:. -San Diego
4373 Vfewridge Avenue, Suite B
San Diego, CA92123
Phone:858-292-7575
Client:
Qufdef Corporation
6675 Si.mmer Ridge Rd
San Diego, CA 92121
Contractor compacts lffts by means of a mechanical tamper.
Project:
1024114
2285 Rutherford Road
2285 Rutherford Road
Csrlsbad, CA 92008
In-place moisture-density tests performed are pending lab
results. Signed by:
Patrick McGinty
07/22/2024
Page 2 of 2
• 3131 Camino Del Rio North. Suite 1080 San Diego. CA 92108 619.521.8500 kpff.com
Quidel
Project Redwood CC2
Structural Calculations
KPFF Project #2400030
CITY
PREV2024-0135
2285 RUTHERFORD RD
QUIDELORTHO: RELOCATE ELECTRICAL PANELS, DOOR
INFILL. RELOCATE FISHBOWL ROOM, UTILITIES AS
REQUIRED.
2120620800
CBC2024-0103 7/3/2024
PREV2024-0135
.,. "'(.,..,..,..,..,.,..,..,..,..,..,..,..,.
3131 Camino Del Rio North, Suite 1080 San Diego, CA 92108 619.521.8500 kpff.com
Quidel
Project Redwood
Clean Rooms CC2
A2
3131 Camino Del Rio North, Suite 1080 San Diego, CA 92108 619.521.8500 kpff.com
Quidel
Project Redwood
Clean Room CC2
Design Criteria
l{pff 3131 Camino Del Rio N
Suite 1080
San Diego, CA 92108
p (619) 521-8500
C .. 1, y f (619) 521-8591
E www.kpff.com
Design Criteria
Use 80/20 extruded aluminum
ro·ect Quidel Pro·ect Redwood
location
client
Cue Clean Room
Ceiling weight = 1 psf + self weight of framing
Max live load = 300 lb at any location
b MS
date 03 08 24
job no. 2400033
Clean room is installed inside existing warehouse = 5psf Wind Load
Seismic Criteria
Use ASCE 7-16 Chapter 12.8
V=CsW
Cs= Sds/(R/le)
Sds = 0. 77 4, see design criteria
R = 1.25
Omega= 2.0
le = 1.0
lcs = 0.619 <-Governs
Csmin = 0.44Sdsle = 0.044 x 0.774 x 1.0 = .0341 < 0.619-> OK
Ceiling Deflection Criteria = D+L <= U120
M Grouoo Molioa pectnil Rcspo[LI;('
Acc-<:leration Class B (short I. s.
\iC'b Cirmu)d Mo1iun . pi!clrul l{i!Sp11r;1,C
Ai:c-eltr.sll,m -Cl.1i,1i, B ( I sti:-), S 1
S itc , oeffic k-ru. F,..
Site Closs Modified MCER Sp¢etrul Re-spoosc
A1: ekrniion (sbort). S'-N
Sicc <'la: :I M,,da6i:d MCP.11 Sr"' ·t1al R L:'f'•lll!jC
A~ccll..'.1 ation -11 1n.'C ~ u1
d Ix ig,i
~I mioon (short►, ~
S% DamJk:d IR sign
cll!'flltiOll I St:c), SIJl
0.) K
1.1
1.161g
0.774g
Figure 1613.2. l I I l
hguru 161 . 112)
T.oblc 16 IJ.2.3( H
CCI ioa 1613 2.3 ◄ Eqo l 6-36)
c:ction 16IJ 2.4 4Eqn 16-3 )
3131 Camino Del Rio North, Suite 1080 San Diego, CA 92108 619.5?1.8500 kpff com
Quidel CC2
Project Redwood
Clean Room
Gravity and Lateral Design
y
II KPFF IRISA f--msn-ook---~
2000409
Cue Vista Clean Room
All member properties
were defined in RISA
to perform analysis.
SK-1
Jun 26, 2024 at 11 :16 AM
Fish Bowl.r3d
Company
D,esigner •
Job Number:
Section Properties: 40-8080-LITE
Section Information:
Material Type = General
Shape Type = Arbitrary
Number of Shapes = 1
Basic Properties:
Total Width = 3.150
Total Height = 3.150
Centroid, Xo = -0.000
Centroid, Yo = -0.000
X-Bar (Right) = 1.575
X-Bar (Left) = 1.575
Y-Bar (Top) = 1.575
Y-Bar (Bot) = 1.575
Max Thick = 3.150
Equivalent Properties:
Area, Ax = 3.142
inertia, lxx = 3.311
Inertia, lyy = 3.311
Inertia, lxy = -0.000
Sx (Top) = 2.102
Sx (Bot) = 2.102
Sy (Left) = 2.102
Sy (Right) = 2.102
rx = 1.026
ry = 1.026
Plastic Zx = 2.942
Plastic Zy = 2.942
Torsional J = 2.051
As-xx Def = 1.000
As-yy Def = 1.000
As-xx Stress = 1.000
As-yy Stress = 1.000
in
in
in
in
in
in
in
in
in ·!•-!
in"2
in"4 ~
in"4
in"4
in"3
in"3
in"3
in"3 Section Diagram
in
in
in"3
in"3
in"4
C:\RISA User Data\msnook\RISASection Files\80-20 Sections.nmsx
~
Mar~~ 15:06 PM 2
Checked By· __ _
v, .... , ... i
Page 1
y
loads· BLC 1. DL
1 psf DL at ceiling and
walls.
II KPFF IRISA f--msn-ook------l
2000409
Cue Vista Clean Room SK-2
Jun 26. 2024 at 11: 19 AM
Fish Bowl.r3d
-1 psi
Loads; BLC 3, Ex
II KPFF IRISA ~msn-ook-------l
2000409
Cue Vista Clean Room SK-3
1 psf+ self weight
applied in X direction,
forces scaled in load
combinations
Jun 26. 2024 at 11:19 AM
Fish Bowl.r3d
y
_, psi
Loads: BLC 4, Ey
II KPFF IRISA i-_;_msn;_c_ook---~
2000409
Cue Vista Clean Room
1 psf+ self weight
applied in Y direction,
forces scaled in load
combinations
SK-4
Jun 26, 2024 at 11 :20 AM
Fish Bowl.r3d
y
Loads: BLC 5, Windy
II KPFF IRISA 1--msn-ook-----t
2000409
Cue Vista Clean Room
5psf wind load,
Y-direction
SK-5
Jun 26, 2024 at 11 :22 AM
Fish Bowl.r3d
y
Loads: BLC 6, WindK
II KPFF IRISA t----msn-ook--------1
Cue Vista Clean Room SK-6
Jun 26, 2024 at 11 :22 AM
2000409 Fish Bowl.r3d
IIIRISA
Company : KPFF
Designer : msnook
Job Number : 2000409
3/13/2024 ~~
4:54:27 PM 2
Checked By : --===
ANEMETSCHEKcoMPANv Model Name : Cue Vista Clean Room
Load Combinations
Descriotion Solve BLC Factor BLC Factor BLC Factor BLC Factor
1 DL
2 LL
3 DL + LL
4 1.4DL
5 1.2DL + 1.6LL
6 1.0DL + 0.7EX +0.21 EY
7 1.0DL + 0.7EY + 0.21EX
8 1.0DL + 0.7EX -0.21 EY
9 1.0DL + 0.7EY -0.21 EX
10 1.0DL + 0.75<0.7EX) + 0.75l0.21EY\ + 0.75LL
11 1.0DL + 0.75f0.7EY) + 0.75f0.21EX) + 0.75LL
12 1.0DL + 0.75/0.7EX) -0.7510.21 EY\ + 0.75LL
13 1.0DL + 0.75l0.7EY) -0.75f0.21 EX)+ 0.75LL
14 0.6DL + 0.7EX +0.21EY
15 0.6DL + 0.7EY + 0.21 EX
16 0.6DL + 0.7EX -0.21EY
17 0.6DL + 0.7EY -0.21EX
18 Omeaa Combinations
19 1.2DL + 2.0/1 .0EX\ + 2.0f0.3EY\ + 0.5LL
20 1.2DL + 2.0I1 .0EY) + 2.0I0.3EX) + 0.5LL
21 1.2DL + 2.0f1 .0EX\ -2.0f0.3EY\ + 0.5LL
22 1.2DL + 2.0I1.0EZ) -2.0/0.3EX) + 0.5LL
23 0.9DL + 2.0f1 .0EX\ + 2.0f0.3EY\
24 0.9DL + 2.0I1 .0EY) + 2.0I0.3EX\
25 0.9DL + 2.0f1 .0EX) -2.0l0.3EY)
26 0.9DL + 2.011 .0EY) -2.0/0.3EX)
27 Wind Combinations
28 1.0DL + 0.6Wx
29 1.0DL + 0.6Wv
30 1.0DL -0.6Wx
31 1.0DL -0.6Wv
32 1.0DL + 0.45Wx + 0.75LL
33 1.0DL + 0.45Wv + 0. 75LL
34 1.0DL -0.45Wx + 0.75LL
35 1.0DL -0.45Wv + 0. 75LL
36 0.6DL + 0.6Wx
37 0.6DL + 0.6Wv
38 0.6DL -0.6Wx
39 0.6DL -0.6Wv
40 self
Cs= 0.619
Omega= 2.0
Yes DL 1
Yes LL 1
Yes DL 1
Yes DL 1.4
Yes DL 1.2
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 0.6
Yes DL 0.6
Yes Dl 0.6
Yes DL 0.6
DL 1.2
DL 1.2
DL 1.2
DL 1.2
DL 0.9
DL 0.9
DL 0.9
DL 0.9
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 1
Yes DL 0.6
Yes DL 0.6
Yes DL 0.6
Yes DL 0.6
OL2 1
Factors were pre-multiplied and inserted into combination
Ex: LC 6
LL 1
LL 1.6
ELX 0.433
ELY 0.433
ELX 0.433
ELY 0.433
ELX 0.325
ELY 0.325
ELX 0.325
ELY 0.325
ELX 0.433
ELY 0.433
ELX 0.433
ELY 0.433
O*ELX 1.238
Q*ELY 1.238
Q*ELX 1.238
O*ELY 1.238
O*ELX 1.238
O*ELY 1.238
O*ELX 1.238
O*ELY 1.238
WLX 0.6
WLY 0.6
WLX -0.6
WLY -0.6
WLX 0.45
WLY 0.45
WLX -0.45
WLY -0.45
WLX 0.6
WLY 0.6
WLX -0.6
WLY -0.6
1.0DL + 0.7(0.619Ex) + 0.21 (0.619Ez) = 1.0DL + 0.433Ex + 0.13Ez
RISA-3D Version 22 [ Clean Room.r3d )
LLS 1.6
ELY 0.13
ELX 0.13
ELY -0.13
ELX -0.13
ELY 0.097 LL 0.75
ELX 0.097 LL 0.75
ELY -0.097 LL 0.75
ELX -0.097 LL 0.75
ELY 0.13
ELX 0.13
ELY -0.13
ELX -0.13
Q*ELY 0.371 LL 0.5
O*ELX 0.371 LL 0.5
O*ELY -0.371 LL 0.5
O*ELX -0.371 LL 0.5
O*ELY 0.371
Q*ELX 0.371
O*ELY -0.371
O*ELX -0.371
LL 0.75
LL 0.75
LL 0.75
LL 0.75
Page 1
IIIRISA
Company KPFF
Designer ms nook
Job Number 2000409
~
6/26/2024~ 1:12:24 PM 2 Checked By:
Model Name Cue Vista Clean Room
Envelope Maximum Member section forces
Member Axial[lb Loclin LC V Shearllb Loclin LC z Shear[lb Loclln LC Torque[lb-ft Loclinl LC v-v Momentllb-ft Loclin LC Z•Z Momenl[lb-ftl Loc(ln LC , M1 max 111 99 151 9 194.279 0 31 66.4<1<; 151 28 10.259 151 8 332.639 151 29 881.158 151 ?Cl
2 min -26.663 0 15 -200.353 151 29 -59.441 151 38 -1.194 0 38 -331.5 0 29 -581.567 0 37
3 M2 max 29.217 151 28 86.761 0 4 23.045 151 8 0.48 151 38 21 75 7,;,; 9 0 151 40
4 min -28.774 0 38 -86.761 151 4 -23.045 0 6 -4.132 75.5 8 -72.495 75.5 8 -272.936 75.5 4
5 M3 max 29.117 151 7 86.761 0 4 23.045 151 8 4.087 75.5 38 21 .75 75.5 17 0 151 40
6 min -28.965 0 17 -86.761 151 4 -23.045 0 6 -34.357 0 6 -72.495 75.5 6 -272.936 75.5 4
7 M4 max 56.072 75.5 38 86.761 0 4 23.114', 151 8 1H12B 75.5 6 21 75 75,; 9 0 151 40
8 min -56.073 0 28 -86.761 151 4 -23.045 0 6 -1.354 75.5 38 -72.495 75.5 6 -272.936 75.5 4
9 M5 max 135.50ll 151 7 ?Rn.:1:.," 0 31 115.297 151 .,,. 18_ .. ., .. 151 8 577 nA7 151 31 111? '\79 0 31
10 min -61.58 0 17 -254.224 151 29 -108.601 151 38 -2.201 100.667 38 -577.179 0 31 -715.73 151 39
11 M6 max 165.30 0 6 187 551 0 8 1nn,_..-, 0 39 15.56 14:m" 39 331.5 0 29 796 144 0 8
12 min -6.765 0 39 -16.211 74.205 38 -105.69 0 29 -21.327 0 29 -294.634 0 39 -392.224 174.20 4
13 M7 max 273.561l 4.20!i 29 73 561 0 8 24 ,.. .. , 74.20! 37 7513 174_7n" 29 ,..,.._.,._u •:.,_411 31 0 74.20 ?
14 min 0 0 2 -34.552 174.205 30 -29.048 74.205 31 -5.948 0 39 -394.944 2.46! 29 -708.289 57.2 4
15 MB max RA.491 74.205 31 151 168 0 6 1nn "~2 0 39 19.033 74.205 31 332.""'Q o 29 560.R'.\.4 0 6
16 min -34.578 0 37 -11 .887 74.20! 38 -106.002 0 29 -10.559 0 37 -293.915 0 39 -397.875 74.20 4
17 UQ M .. Y 292.552 0 8 132415 0 6 24.778 74.20! 37 65.157 74.205 31 396.IXlfi 22.41 31 347.59 0 14
18 min 0 0 2 -38.094 74.205 38 -29.014 74.205 31 -56.06 0 37 -395.145 1.69 29 -581.565 4.20 4
19 M10 max 1~764 o 6 22.362 0 4 1<1.913 0 31 22.~Q:l 74 ·m-. 39 21."n" 7.102 31 0 4.20 40
20 min -26.222 0 38 -22.362 174.205 4 -13.913 0 37 -23.468 0 29 -21.509 7.10 37 -34.571 7.10 4
21 M11 max 14<1881 0 6 22.362 0 4 13.913 0 31 An R61 74.205 39 21 """ 7.10 31 0 4.20 40
22 min -4.777 0 38 -22.362 174.205 4 -13.913 0 29 -83.7 0 29 -21.509 37.10 37 -34.571 7.102 4
23 M12 max 53.315 0 16 22.362 0 4 13.913 0 39 33.248 74:m" 31 21 509 37.10 39 0 4.20 40
24 min -25.59 0 30 -22.362 174.205 4 -13,913 0 29 -24.962 0 37 -21.509 7.10 29 -34.571 7.10 4
25 M13 max 4.726 0 16 22.362 0 4 13.913 4.20! 37 13.Rn.4 74.205 29 21. '<flU 7.10 39 0 4.20 40
26 min -5.522 174.20' 6 -22.362 74.20" 4 -13.913 4.205 31 -12.643 0 39 -21.509 37.10 29 -34.571 7.10 4
27 M14 M<>Y 523.66 0 4 199.624 90 39 136 493 0 6 0 90 40 400.88 5.62 6 1112.399 90 29
28 min 0 0 2 -270.319 36.56 29 -267.38 36.56 4 0 0 1 -952.508 90 30 -778.612 90 39 ?Q M15 max 564.289 0 4 282.441 90 31 11A f\73 0 8 o 90 40 347 077 5.62 8 705 111.1 <IO <17
30 min 0 0 2 -197.756 36.563 37 -271.144 36.563 4 0 0 1 -964.251 90 4 -1107.023 90 31
31 M16 max 0 74.20! 2 32.102 0 4 34.784 o 37 533.013 74.205 29 53 773 37.10 37 0 4.20 40
32 min -447.92 0 8 -32.102 4.20! 4 -34.784 0 31 -531.938 0 39 -53.773 7.10 31 -49.627 7.10 4
33 M17 max 35 399 4.20! 38 32.102 0 4 34 7R4 4.205 39 241 202 74.205 211 53 77?. 37.10 37 0 74.20 40
34 min 191,736 0 8 -32.102 4.205 4 -34.784 4.205 29 -235.837 0 39 -53.773 37.10 31 -49.627 7.102 4
35 M18 max 0 90 2 97.394 53.4:Y :l1 86.444 90 16 0 90 40 151.941 54.37 30 433.708 3.43 37
36 min 147.422 0 4 -97.394 0 29 -58.857 0 16 0 0 1 -252.357 53.43 16 -433.708 3.43 31
37 M19 max 0 90 2 97.394 53.438 39 83.778 90 16 0 90 40 156.729 54.37 <In 433.708 53.43 29
38 min 147,422 0 4 -97.394 0 29 -57.08 0 16 0 0 1 -244.443 53.43 16 -433.708 53.43 31
39 M20 M"Y 0 4.20! 2 32.102 0 4 34,784 0 37 511 .838 74.205 31 53.773 37.10 37 0 74,20 40
40 min 356.444 0 4 -32.102 4.20! 4 -34.784 0 39 -510.764 0 37 -53.773 37.10 39 -49.627 7.10 4
RISA-30 Version 21 [ Fish Bowt.r3d J Page 1
IIIRISA
Company
Designer
Job Number
Model Name
KPFF
msnook
2000409
Cue Vista Clean Room
Envelope Maximum Member Section Forces (Continued)
Member Axialllb Loclin LC v Shearllbl Locfin LC
41 M21 mav n 74.20! 2 32.102 0 4
42 min 342.11! 0 4 -32.102 l74.20E 4
43 M22 max 0 QO 2 97.394 53.431 39
44 min 147.422 0 4 -97.394 0 29
45 M23 m"X 0 Qn 2 97.394 53.438 39
46 min 147.422 0 4 -97.394 0 29
47 M24 max 20.663 4.20! <18 32.102 0 4
48 min -72.363 0 28 -32.102 74.20E 4
49 M25 max 1110 0.1< n 1"-<t?.102 0 4
50 min -75.874 0 30 -32.102 74.201 4
51 M26 max 0 74.20' 2 32.102 0 4
52 min 174.W 387.433 6 -32.102 4.20! 4
53 M27 max 0 74.20' 2 32.102 0 4
54 min 362.359 0 4 -32.102 4.20! 4
55 M28 mav 370.546 90 8 109.475 53.438 37
56 min -12.848 0 17 -188.971 0 31
57 M29 max 365.458 90 7 197.479 53.438 29
58 min -5.094 0 39 -104.508 0 39
59 M30 max n 90 ., 97 <IQ4 53.438 31
60 min -147.422 0 4 -97.394 0 37
61 M31 max 0 90 ., 97 "IQ4 53.438 39
62 min -147.422 0 4 -97.394 0 37
63 M32 max 63.537 151 7 51.609 0 4
64 min -63.537 0 7 -51.609 151 4
65 M33 max 12.208 90 4 113.082 90 29
66 min -91.61 0 4 -108.812 54.37! 39
67 M34 max 40 "11 7,;_5 37 32.662 0 4
68 min 163.737 0 31 -32.662 75.5 4
6Q M3<i mav ,11:: 1AO 7,;_,; 39 32.662 n d
70 min 167.391 0 29 -32.662 75.5 4
71 M36 max 0 M.00 , 78.305 54.376 39
72 min -75.189 0 4 -116.537 90,00: 29
73 M37 max n !l0.00 , 82.302 0 31
74 min -75.59 0 4 -123.398 ~0.002 31
75 M38 max 11A.38 0 9 16.212 0 4
76 min -78.211 0 39 -15.15 51 4
77 M39 max 123.482 51 31 15.065 0 4
78 min -79.102 51 17 -15.018 51 4
79 M40 max 130.604 50.667 39 21.485 0 4
80 min -193.951 0 29 -21.707 50.667 4
81 u41 mav 128.363 50.661 37 22.228 0 4
RISA-3D Version 21
~
6/26/2024~
1:12:24 PM 2 Checked By :
z Shearllbl Loclin LC Torauellb-ftl Loclinl LC v-v Momentflb-ft Loclin LC z-z Momentllb-ftl Loclin LC
34 784 74.205 39 11 ?59 74.205 29 5'.'I. 773 37.102 <17 0 74.20 40
-34.784 74.205 29 -10.184 0 39 -53.773 37.102 31 -49.627 37.10 4
109.329 90 6 n 90 40 155.693 54.37 38 433 708 53.43 29
-74.115 0 6 0 0 1 -320.296 53.43 6 -433.708 53.43 39
107.832 90 6 n 90 40 158.294 54.37 38 433.708 3.43 29
-73.117 0 6 0 0 1 -315.849 53.43 6 -433.708 3.43 39
34.784 0 31 234.023 74.205 29 53.773 G7.10 31 0 4.20 40
-34.784 0 37 -232.416 0 39 -53.773 G7.10 37 -49.627 7.10 4
34.784 74.205 '.'1.7 289.739 74.7n~ 31 53.773 37.102 39 0 4.20 40
-34.784 74.205 31 -288.132 0 37 -53.773 G7.102 29 -49.627 37.10 4
34.784 0 31 168 796 74 205 37 5' 77'.l 37.10 31 0 74.20 "-0
-34.784 0 29 -172.141 0 31 -53.773 37.16: 29 -49.627 7.10 4
3A 784 4.205 37 350.449 74 205 3Q 53.773 137.102 39 0 4.20! 40
-34.784 4.205 31 -353.794 0 29 -53.773 37.102 29 -49.627 37.10: 4
1110.245 53.438 A 0 90 40 21Q.492 n 00 561.681 0 37
-39.181 54.375 30 0 0 1 -806.403 0 8 -829.179 0 31
119.146 53.438 II 0 90 40 1119.109 0 '.'1.8 872.718 0 29
-37.751 54.375 30 0 0 1 -550.941 0 6 -539.695 0 39
274 229 53.438 6 0 90 40 167.429 54.37! 4 287.897 QO ?9
-56.397 54.375 4 0 0 1 -1193.869 0 6 -274.504 90 39
84.738 90 15 0 90 40 154.336 54.37! 30 433.708 53.431 37
-57.72 0 16 0 0 1 -247.292 53.431 16 -433.708 53.431 31
48.?78 0 38 10.7nA 151 8 214_,::oi; 75.5 38 0 151 40
-48.673 0 28 -1.566 75.5 17 -217.166 75.5 28 -181.555 75.5 4
39.159 90 36 3.943 90 39 1311.Rd ,3.431 38 335.712 54.375 29
-39.811 IY .375 30 -15.647 0 6 -141.545 53.431 28 -323.037 154.375 39
3,;_3Q1 7,;_5 <I.I\ ?7 ''7 75.5 8 55.667 37.75 38 0 75.5 40
-35.391 75.5 30 -12.29 0 38 -55.667 37.75 28 -51 .374 37.75 4
35 391 7,;" <I.I\ 11\ AA<: 75,; 30 ,;,;_,::117 37 .,, <IA 0 75 <: 40
-35.391 75.5 30 -4.124 0 36 -55.667 37.75 28 -51 .374 37.75 4
32.412 53.43! 28 1.?83 'i'.'I. 439 36 144.338 53.43 28 232 408 53.43! "" -32.412 0 30 -1.283 0 30 -144.338 53.43 30 -345.869 53.43 29
33.3""-53.43' 30 1 31 53 439 38 148.534 53.43 30 228 413 53.43! 37
-33.354 0 28 -1.31 0 36 -148.534 53.43' 28 -366.24 53.43! 31
11.377 0 36 0 51 40 10.075 ?3.9 <l6 0 51 Al\
-11.377 0 30 0 0 1 -10.075 ?3.906 30 -16.276 24.969 4
8.918 0 28 0 51 40 10.643 25.5 28 0 51 40
-8.918 0 38 0 0 1 -10.643 25.5 38 -16.553 25.5 4
?3.316 50.667 '.'1.0 173.15 50.667 38 20.997 25.861 ?8 0 50.661 40
-23.316 50.667 36 -173.15 0 28 -20.997 25.861 38 -21.221 125.861 4
2A A<:3 50.661 ~8 176.855 50667 28 22.964 25.333 36 0 50.66 40
[ Fish Bowl.r3d J Page 2
IIIRISA
Company
Designer
Job Number
Model Name
KPFF
msnook
2000409
Cue Vista Clean Room
Envelope Maximum Member Section forces (Continued}
Member Axialnb Loclin LC v Shearllbl Loclin LC
82 min 205.384 0 31 ·22.243 .tl.66 4
83 M42 max 351.346 74.20 6 324.722 4.20! 4
84 min --6.559 0 39 ·201.815 2.65S 4
85 M43 max 279.101 4.20! 29 0 4.20! 2
86 min 0 0 2 ·297.297 4.20! 4
87 M44 mu 160.127 148.41 31 356.462 74.20! 4
88 min -90.016 174.205 14 ·221.416 172.65! 4
89 M45 max 284.67! 4.211! 31 0 74.205 2
90 min 0 0 2 ·265.557 74.205 4
91 M46 max 152.543 151 9 312.249 0 31
92 min -70.077 0 15 ·311.814 151 29
93 M47 max ~.904 0 4 274.AA't 90 39
94 min 0 0 2 ·359.626 6.563 29
95 M48 max 849.417 0 4 369.945 90 31
96 min 0 0 2 -280.596 6.56, 37
97 ...... MAX 0 !lll.002 2 98.202 4.37! 39
98 min -75.602 0 4 -1 42.278 n.oo 29
99 M50 max 0 00.00: 2 99.945 4,37! 37
100 min -75.148 0 4 ·147.704 0.00, 31
101 M51 m,ox 142.362 ,;1 29 15.019 0 4
102 min -98.109 0 39 ·15.067 51 4
103 M52 max 147.785 51 31 15.15 0 4
104 min -99.851 0 37 ·16.212 51 4
1n• u,;3 max 163.768 50.667 39 22.241 0 4
106 min 236.852 0 29 ·22.228 50.667 4
107 M54 max 166.671 511.66 37 21.707 0 4
108 min 245.899 0 31 -21.485 'ill.66I 4 p, M55 max 52,K:H 74.20! 30 22:<fi, 0 4
110 min l-88.374 4.20! 14 ·22.362 4.20! 4
111 M56 max 52.524 74.2n 30 22.31:? 0 4
112 min -99.237 4.20 16 ·22.362 4.20! 4
113 M57 max 126.222 74.20 38 22.362 0 4
114 min --64.764 74.20 6 ·22.362 74.20! 4
115 M58 max 55.471 0 14 22.362 0 4
116 min -53.968 0 30 ·22.362 74.20! 4
1117 M59 max 25.'i9 4.20! 30 22.36? 0 4
118 min -53.315 4.20! 16 -22.362 74.205 4
119 11.460 max 99.557 0 16 22.362 0 4
120 min -52.256 0 30 ·22.362 74.20! 4
121 M61 max 0 74.2uo 2 32.102 0 4
17~ min -121.94 0 4 -32.102 174.205 4
RI SA-30 Version 21
z Shearflbl
·24.463
152.957
·157.102
163.89"
-168.181
152.861
·157.238
163.913
-168.15
74.14
-43.179
192.901
·36.613
324.18
·56.522
16,354
-4.907
4.866
·16.219
3.362
.3_377
3.403
·3.731
5_1:n1:
-5.602
5.441
·5.372
13.913
·13.913
13.913
·13.913
13.913
·13.913
13.913
-13.913
13.913
-13.913
13.913
·13.913
't.4,784
-34.784
~
6/26/2024~
1:12:24 PM 2 Checked By :
Loclin LC Torauellb-ftl Loclinl LC v-v Momentllb•ft Loclin LC Z·Z Moment(lb·ft Loc[in LC
50.667 28 -176.855 0 38 -?2.964 5.33 30 -22.145 5.33 4
74,205 39 15.56 74.205 39 471.609 4.20 29 1246.807 4.205 8
174.205 29 -21.327 0 29 -435.169 4.20 39 --633.54 148.41 4
74.20! 37 7.513 74.205 29 "'\A ,!IR1 4.20 37 974 13? 4.20: 4
74.20! 31 ·5.948 0 39 -577.179 4.20 31 -705.92 0 4
174.205 39 127.598 148.41 37 472.176 4.20 29 1120.255 4.20 4
174.205 29 -146.416 74.205 31 -434.771 74.20 39 -925.657 148.41 4
4.205 37 65157 74.?0'i 31 535.032 4.20 37 951 886 4.20! 30
4.205 31 -56.06 0 37 -577.087 74.20 31 -575.392 0 4
151 6 6.871 151 8 330.373 151 29 1361.387 0 31
0 16 -0.797 0 38 -330.409 0 29 -933.037 0 37
16.56, 6 0 90 40 KMJ< '.<KM 90 6 1454.811 90 29 36.56, 38 0 0 1 -249.202 90 38 -1059 182 90 39
36.56 8 0 90 An 1286""" 90 8 95n nAA 90 37
0 4 0 0 1 -296.532 90 38 -1381.061 90 31
D 8 0 579 53.439 8 l:'t078 53.43 R ?91.48 53.43 39
0 17 -0.174 0 17 ·18.925 53.43 17 -422.292 3.43 29
0 9 0.173 53.439 9 18.744 3.43 9 296.654 3.43 37
0 6 ·0.575 0 6 -62.475 53.43 6 -438 402 3.43 31
0 6 0 51 40 3.757 25.5 6 0 51 40
51 8 0 0 1 ·1 .127 25.5 9 ·16.554 25.5 4
0 6 0 51 40 3.672 6.031 6 0 51 40
51 8 0 0 1 ·1.102 6.031 9 ·16.276 6.031 4
0 8 ?'t 461 ,;n,:,:7 17 """" 5.33 8 0 0.66 40
50.661 6 -78.197 0 8 ·1.652 5.33 17 -22.143 5.33 4
0 6 77.665 50,667 6 522 4,IU 6 0 n,66 40 0.667 8 -23.301 0 9 ·1.566 4.8C 9 -21.221 4.8~ 4
4.20! 37 80."',1 7A 205 39 21 509 7.10 39 0 74.20 40
4.205 31 -83.7 0 29 ·21509 7.10 29 ·34.571 37.10 4
4.20! 29 13.804 74.205 29 21 509 7.10 31 0 74.20 40
4.20! 39 ·12.643 0 39 -21.509 7.10 37 -34.571 7.10 4
4.20! 37 22.393 74.205 39 21 509 7.10 39 0 4.20 40
4.205 31 -23.468 0 29 ·21.509 37.10 29 ·34.571 17.10 4
4.20! 29 204.197 74.205 29 21.509 7.10 31 0 4.20! 40
4.20! 39 -193.843 0 39 -21.509 7.10 37 -34.571 37.102 4
4.20! 29 33.248 174.205 31 21 509 7.10 31 n 174.20! 40
4.205 39 -24.962 0 37 -21.509 7.10 37 -34.571 7.102 4
4.20! 29 13.804 74.205 29 71 509 7.10 31 0 4.20 AO
74.20! 39 ·12.643 0 39 -21.509 7.10 37 ·34.571 7.10 4
0 29 287.258 • 14.205 31 53.773 7.10 29 0 4.20 40
0 '(U ·281.893 0 37 .53.773 7.10 39 -49 627 7.10 4
[ Fish Bowl.r3d ] Page 3
IIIRISA
RISA-3O Version 21
Company
Designer
Job Number
Model Name
KPFF
msnook
2000409
Cue Vista Clean Room
[ Fish Bowl.r3d )
~
6/26/2024~
1:12:24 PM 2 Checked By :
Page4
lq:ttf 3131 Camino Del Rio N ro·ect b
Suite 1080
San Diego, CA 92108 location date
p (619) 521-8500
f (619) 521-8591 client job no.
www.kpff.com
I to check the Individual elements for local I bucking
Element 1 ~ Element 2
bllnl 0.5 bllnl 0.75
tflnl 0.1299 tlinl 0.1299
Eflull 10153 E lksl) 10153
Fcv (ksll 35 Fcv lksll 35
Ae 21.80 Ae 21.80
Al 33.46 Al 33.46
ds flnl 0.25 ds flnl 0.25
8 90 8 90
rs 0.14 rs 0.14
oST 1.00 oST 1.00
Element 1 Element 2
Element Stress Element Support Fe Aeq Element Stress Element Support Fe
Flat Sunnnrted on 80th Ed•es 2642.00 6.2 Fiat Su•=rted on 80th Ed•es 1174.22
fiat Sunnnrted on One Ed•e 270.54 19.2 Fiat Sunnnrted on One Ed•• 120.24
fiat Supported on one edge with a 2642.00 6.2 siffener on the other edge Flat Supported on one edge with a 272.37 siffener on the other edge
Elastic buckling stress of elements for compression was checked per
Aluminum Design Manual and it was found that it was not the governing
factor since the element lengths are small. Local bucking of elements is not
an issue for these members.
Table 8.5.1
ELASTIC BUCKLING STRESS F0 OF ELEMENTS
Elomont Type ElorMnt StreH Elemtnl Support
llal unilo<m comp,e$llorl Supporled OIi bOlh edge,
llal ooto<m ~ supporled o,, one edge
flat
unilo<m _...ion slJIJl)0(10d o,, bolh edges and wilh an ime,,,_te sbllonor
eurwd
Note:;.. Is determined from equatoon 8.5-10
F,
rt'E
(1.61111)'
rt'E
(5WI)'
e
b
$-•
CIOU.hMCneel
I °' I
Aeq
9.2
28.9
19.2
I ' ' l
oroiect Quidel bv MS tJl 18 1 eet no.
l{!Jff
3131 Camino Del Rio N ···'A Suite 1080 location San Diego date 3/13/24 San Diego, CA 92108
p (619) 521-8500 I ...
f (619) 521-8591 client job no. 2400030
JHlC www.kpff.com
E (ksi) 10200 Be 39.36527 De 0.244551 Cc 65.99748
Fey (ksi) 35 Bp 45.00139 Op 0.298909 Cp 61.72641
Bbr 66.82428 Dbr 0.662441 Cbr 67.25058
Table 8.4.2
BUCKLING CONSTANTS FOR TEMPER DESIGNATIONS
BEGINNING WITH TS, T6, T7, TS, OR T9
Type of Stress and Member Intercept Slope Intersection
Compression in Columns and Beam Flanges 8c c F.,(1 + (22~J") D. = 8•(~)"'' c. = o.41 8•
10 E D,
Axial Compression in Flal Elemenls 8p=F.,(1 +(~)'°) D -~(~)'" • 10 E
Cp = 0.418• o.
Axial Compression in Curved Elements 81 = F.,(1 + (50.~Kr) 0,=~(~)',. 4.5 E C, see note 2
Bending Compression in Flat Elements 8., = 1.3F.,( 1 + (~gJo) 0.,=!3;(
6:•r C.,=28.,
30.,
Bending Compression in Curved Elements 8., • 1.5F.,(1 + (_fg__)") 50,000K
Oro = 8., (8•)'" 2.7 E
c,. = (8., -s,)'
D.,-D,
Shear in Fla.I Elements 8,=F,.(1 +(~r) D ,. 8,(~)""
' 10 E
c, = 0.4,1 8• D,
Noles
t .-. IO ksi (6 895 MPa) 2. C, shall be dalermined using a plol ol cunies ol lim1I slale sttess based on elastic and inelastic buckhng or by trial and error solution.
40-8080-LITE
Table B.4.3 L (in) 90
POSTBUCKLING CONSTANTS K 2
r(in) 1.03
Type of Element lr1 le, Al 17.85
Flat Elemenls in compression for Temper 0.50 2.04
Designations Beginning with 0 , H, T1, A2 66.00
T2, T3, or T4. and weld-affected zones A 175.44
of all 1empers
A(in2) Flal Elements in Compression for Temper 0.35 2.27 3.142
Designations Beginning with TS, T6,
TT. TB, orT9
Flat Elements in Flexure 0.50 2.04 Fe 2.780152
<l>Pc 7.861714
Axial Capacity is Based on Global Buckling of Members
Using the Aluminum Design Code ADM Section B.5
FromManuf~
Member Properties V My Mz Axial Strencth
Sha Area lz d dz Orne a Fy (ksl) (kl (lb) (k"I (lb'I (k"I (lb') (lbl
40-8080-LITE 3.142 3.311 3.311 1.575 1.575 2.051 1.65 35 66.65 66648 44.59 3716 44.59 3716 7861. 71
Shear Capacity:
V = (Area*Fy)/Omega = 66.65k
Moment Capacity:
My = Mz = (Fy*(ly/dy))/Omega = 44.59k"
Axial Strength:
See previous pages
Ml max
40-8080-LITE min
Ml max
40-8080-LITE min
M2 max
40-8080-LITE min
Ml max
40-8080-LITE min
M4 max
40-8080-LITE min
MS max
40-8080-LITE min
M6 max
40-8080-LITE min
M7 max
40-8080-LITE min
MB max
40-8080-LITE min
M9 max
40-8080-LITE min
MlO max
40-8080-LITE min
M11 max
40-8080-LITE min
M12 max
40-8080-LITE min
M13 max
40-8080-LITE min
M14 max
40-8080-LITE min
M15 max
40-8080-LITE min
M16 max
40-8080-LITE min
M17 max
40-8080-LITE min
MlB max
40-8080-LITE min
M19 max
40-8080-LITE min
M20 max
40-8080-llTE min
M21 max
40-8080-LITE min
M22 max
40-8080-LITE min
M23 max
40-8080-LITE min
M24 max
40-8080-LITE min
M25 max
40-8080-LITE min
M26 max
40-8080-LITE min
M27 max
40-8080-LITE min
M28 max
40-8080-LITE min
M29 max
40-8080-LITE min
M30 max
40-8080-LITE min
M31 max
40-8080-LITE min
M32 max
40-8080-LITE min
M33 max
40-8080-LITE min
M34 max
40-8080-LITE min
M35 max
40-8080-LITE min
M36 max
40-8080-LITE min
M37 max
40-8080-LITE min
Summary Of Member Forces
Axial (lb) Y Shear (lb) Z Shear (lb) Torque (lb') Y Moment (lb') Z Moment (lb')
115.24 305.17 85.21 2.91 357.96 1463.48
44.24 305.17 85.21 2.91 357.96 1124.64
112.00 194.28 66.50 10.26 332.64 881.16
26.66 200.35 59.44 1.19 331.50 581.57
29.22 86.76 23.05 0.48 21.75 0.00
28.77 86.76 23.05 4.13 72.50 272.94
29.12 86.76 23.05 4.09 21.75 0.00
28.97 86.76 23.05 34.36 72.50 272.94
56.07 86.76 23.05 11.53 21.75 0.00
56.07 86.76 23.05 1.35 72.50 272.94
135.51 260.03 115.30 18.53 577.09 1112.58
61.58 254.22 108.60 2.20 577.18 715.73
165.30 187.55 100.63 15.56 331.50 796.14
6.77 16.21 105.69 21.33 294.63 392.22
273.57 73.56 24.76 7.51 396.26 0.00
0.00 34.55 29.05 5.95 394.94 708.29
68.49 151.17 100.43 19.03 332.64 560.63
34.58 11.89 106.00 10.56 293.92 397.88
292.55 132.42 24.78 65.16 396.01 347.59
0.00 38.09 29.01 56.06 395.15 581.57
64.76 22.36 13.91 22.39 21.51 0.00
26.22 22.36 13.91 23.47 21.51 34.57
43.88 22.36 13.91 80.66 21.51 0.00
4.78 22.36 13.91 83.70 21.51 34.57
53.32 22.36 13.91 33.25 21.51 0.00
25.59 22.36 13.91 24.96 21.51 34.57
4.73 22.36 13.91 13.80 21.51 0.00
5.52 22.36 13.91 12.64 21.51 34.57
523.67 199.62 136.49 0.00 400.88 1112.40
0.00 270.32 267.38 0.00 952.51 778.61
564.29 282.44 118.67 0.00 347.98 705.18
0.00 197.76 271.14 0.00 964.25 1107.02
0.00 32.10 34.78 533.01 53.77 0.00
447.92 32.10 34.78 531.94 53.77 49.63
35.40 32.10 34.78 241.20 53.77 0.00
191.74 32.10 34.78 235.84 53.77 49.63
0.00 97.39 86.44 0.00 151.94 433.71
147.42 97.39 58.86 0.00 252.36 433.71
0.00 97.39 83.78 0.00 156.73 433.71
147.42 97.39 57.08 0.00 244.44 433.71
0.00 32.10 34.78 511.84 53.77 0.00
356.44 32.10 34.78 510.76 53.77 49.63
0.00 32.10 34.78 11.26 53.77 0.00
342.12 32.10 34.78 10.18 53.77 49.63
0.00 97.39 109.33 0.00 155.69 433.71
147.42 97.39 74.12 0.00 320.30 433.71
0.00 97.39 107.83 0.00 158.29 433.71
147.42 97.39 73.12 0.00 315.85 433.71
20.66 32.10 34.78 234.02 53.77 0.00
72.36 32.10 34.78 232.42 53.77 49.63
119.81 32.10 34.78 289.74 53.77 0.00
75.87 32.10 34.78 288.13 53.77 49.63
0.00 32.10 34.78 168.80 53.77 0.00
387.43 32.10 34.78 172.14 53.77 49.63
0.00 32.10 34.78 350.45 53.77 0.00
362.36 32.10 34.78 353.79 S3.77 49.63
370.55 109.48 180.25 0.00 219.49 561.68
12.85 188.97 39.18 0.00 806.40 829.18
365.46 197.48 89.15 0.00 189.11 872.72
5.09 104.51 37.75 0.00 550.94 539.70
0.00 97.39 274.23 0.00 167.43 287.90
147.42 97.39 56.40 0.00 1193.87 274.50
0.00 97.39 84.74 0.00 154.34 433.71
147.42 97.39 57.72 0.00 247.29 433.71
63.54 51.61 48.28 10.70 214.69 0.00
63.54 51.61 48.67 1.57 217.17 181.56
12.21 113.08 39.16 3.94 138.64 335.71
91.61 108.81 39.81 15.65 141.55 323.04
49.61 32.66 35.39 27.34 55.67 0.00
163.74 32.66 35.39 12.29 55.67 51.37
46.15 32.66 35.39 10.45 55.67 0.00
167.39 32.66 35.39 4.12 55.67 51.37
0.00 78.31 32.41 1.28 144.34 232.41
75.19 116.54 32.41 1.28 144.34 345.87
0.00 82.30 33.35 1.31 148.53 228.41
75.59 123.40 33.35 1.31 148.53 366.24
tmt~~i ::ft]~i~)t~2l~!~l: ?;~·: ;;;;:; '~~;:..~:
:,:',:/9;,w?, ..... :;:;-:\:'.Q;·ih?(: ::,•:•,:/::t®.D·'. '/ ::,.,·.;;:,.,;w;iit·/.:•:. ,. >:.: 'i,~1 •• ·:,,,:r-·:&,~ft::c::: '-:,::•:::::\o'u ':?<' t>::'<#.;5f/:/ , ·,::,-:.,:?iio.i~t< • ,,:,o-.~
)f \)i~\Y f:)::fVO.: .. {'f~,::.; ·: ':',:-:_:2a,,1::{. ::··:,JAl
.:·:0,:10:.'.':;(.,: · :-:::-:::.:;:.:.0.:0!/:: ,.;.:::.:-:.,::.,::. a.9,2_ :-::• .. :•" '15;$ ;,:.:::,:.: • '/.' '• 0.34. :-: ,•
. •
M38 max 118.38 16.21
40-8080-LITE min 78.21 15.15
M39 max 123.48 15.07
40--8080-LITE min 79.10 15.02
M40 max 130.60 21.49
40--8080-LITE min 193.95 21.71
M41 max 128.36 22.23
40--8080-LITE min 205.38 22.24
M42 max 351.35 324.72
40-8080-LITE min 6.56 201.82
M43 max 279.11 0.00
40--8080-LITE min 0.00 297.30
M44 max 160.13 356.46
40--8080-LITE min 90.02 221.42
M45 max 284.68 0.00
40-8080-LITE min 0.00 265.56
M46 max 152.54 312.25
40--8080-LITE min 70.08 311.81
M47 max 900.90 274.84
40--8080-LITE min 0.00 359.63
M48 max 849.42 369.95
40-8080-LITE min 0.00 280.60
M49 max 0.00 98.20
40--8080-LITE min 75.60 142.28
M50 max 0.00 99.95
40-8080-LITE min 75.15 147.70
M51 max 142.36 15.02
40--8080-LITE min 98.11 15.07
M52 max 147.79 15.15
40-8080-LITE min 99.85 16.21
M53 max 163.77 22.24
40-8080-LITE min 236.85 22.23
M54 max 166.67 21.71
40--8080-LITE min 245.90 21.49
M55 max 52.83 22.36
40--8080-LITE min 88.37 22.36
M56 max 52.52 22.36
40--8080-LITE min 99.24 22.36
M57 max 26.22 22.36
40-8080-LITE min 64.76 22.36
M58 max 55.47 22.36
40--8080-LITE min 53.97 22.36
M59 max 25.59 22.36
40--8080-LITE min 53.32 22.36
M60 max 99.56 22.36
40-8080-LITE min 52.26 22.36
M61 max 0.00 32.10
40--8080-LITE min 121.94 32.10
M62 max 0.00 32.10
40-8080-LITE min 134.77 32.10
11.38 0.00
11.38 0.00
8.92 0.00
8.92 0.00
23.32 173.15
23.32 173.15
24.46 176.86
24.46 176.86
152.96 15.56
157.10 21.33
163.90 7.51
168.18 5.95
152.86 127.60
157.24 146.42
163.91 65.16
168.15 56.06
74.14 6.87
43.18 0.80
192.90 0.00
36.61 0.00
324.18 0.00
56.52 0.00
16.35 0.58
4.91 0.17
4.87 0.17
16.22 0.58
3.36 0.00
3.38 0.00
3.40 0.00
3.73 0.00
5.61 23.46
5.60 78.20
5.44 77.67
5.37 23.30
13.91 80.66
13.91 83.70
13.91 13.80
13.91 12.64
13.91 22.39
13.91 23.47
13.91 204.20
13.91 193.84
13.91 33.25
13.91 24.96
13.91 13.80
13.91 12.64
34.78 287.26
34.78 281.89
34.78 225.14
34.78 213.96
10.08 0.00
10.08 16.28
10.64 0.00
10.64 16.55
21.00 0.00
21.00 21.22
22.96 0.00
22.96 22.15
471.61 1246.81
435.17 633.54
534.98 974.13
577.18 705.92
472.18 1120.26
434.77 925.66
535.03 951.89
577.09 575.39
330.37 1361.39
330.41 933.04
888.39 1454.81
249.20 1059.18
1286.10 960.04
296.53 1381.06
63.08 291.48
18.93 422.29
18.74 296.65
62.48 438.40
3.76 0.00
1.13 16.55
3.67 0.00
1.10 16.28
5.51 0.00
1.65 22.14
5.22 0.00
1.57 21.22
21.51 0.00
21.51 34.57
21.51 0.00
21.51 34.57
21.51 0.00
21.51 34.57
21.51 0.00
21.51 34.57
21.51 0.00
21.51 34.57
21.51 0.00
21.51 34.57
53.77 0.00
53.77 49.63
53.77 0.00
53.77 49.63
No DIC greater than
100% -> All members OK
Torque Specifications
The tables below show the amount of torque in foot-lbs. and
newton meters required to activate th e 2 degree drop-lock feature
for t-slotted profiles. Nut and bolt combination is preloaded when
tightened to the minimum torque rating.
Fractional T-slotted Profiles
Fastener Description Tested Profile
3320 5/16-18 x 11/16 Flanqed BHSCS & Economv T-Nut 1515
3325 5/16-18 x 3/4 Economv T-Slot Stud, Washer & Hex Nut 1515
3360 15 Series Anchor Fastener Assemblv 1515-Lite
3380 15 Series End Fastener Assemblv 1515-Lite
3321 1/4-20 x 1/2 Flanqed BHSCS & Economv T-Nut 1010
3395 10 Series Anchor Fastener Assemblv 1010
3381 1 O Series End Fastener Assemblv 1010
Metric T-slotted Profiles
Drop-Lock
Engaged ;._~..t:!::::.=~::::i..._---,
Minimum Torque Ft-lbs.
10.00 15.00
25.00 30.00
10.00 20.00
10.00 22.00
4.00 6.00
3.00 17.00
4.00 17.00
Fastener Description Tested Profile Minimum Torque Newton Meters Maximum Torque Newton Meters
75-3422 MS x 16mm BHSCS & Economv T-Nut 40-4040 13 20
75-3500 M8 x 20mm Economv T-Slot Stud, Washer & Hex Nut 40-4040 40 54
40-3897 40 Series Anchor Fastener Assemblv 40-4040-Lite 13 37
40-3891 40 Series End Fastener Assemblv 40-4040-Lite 13 29
75-3404 MS x 10mm BHSCS & Economv T-Nut 25-2525 5 8
25-3896 25 Series Anchor Fastener Assemblv 25-2525 4 23
25-3895 25 Series End Fastener Assemblv 25-2525 5 23
The estimated torque calculations in this chart are offered as a guide only. Use of this content by anyone is the sole responsibility of that person and they assume all risk. Due to many
variables that affect the torque-tension relationship like human error, s11rface textu,,. and lubrication the only way to determiM the correct torque is through experimentation under
actualjointandassemblyconditions. Double values since using
(2x) bolts = 5001bs. All shear
Fastener Application Test reactions < S00lbs -> OK
1 : Single Anchor 2: Double Anchor
6: Corner Bracket 7: Corner Gusset
3 450 200
4 175 50
6 325 75
7 325 220
8
9
3: End Fastener 4: Flat Plate
8: Inside -Inside 9: Inside· Outside
Corner Connector Corner Connector
700
500
200
'200:,,···,
225
260 375 750
50 50
240 220
Horizontal Profile Dimension
A: Direct Force
10 Series= 5.000" B: Cantilevered
__ .....,_... 15 Series = 6.000" C: Tortional Force
1150
680
1 000
• • :·. ,/ 1-:1·20 1 260
500 500
500 750 500
50
240
For the most up to date information on 80/20" products visit 8020.net
3131 Camino Del Rio North, Suite 1080 San Diego. CA 92108 619.521.8500 kpff.com
Quidel
Project Redwood
Clean Room CC2
Anchorage Design
8
Joint Reactions •red reactions require two anchors Max Reactions ~
X (lb) Abs Val Y (lb) Abs Val Z (lb) X Max(lb) Y Max (lb) Z Max(lb)
N6 max 590.50 590.50 725.79 725.79 1027.15 1046.93 1158.55 -419.36
N6 min -219.14 219.14 -154.73 154.73 -419.36
NS max 1024.28 1024.28 896.73 896.73 1283.27
NS min -221.73 221.73 -254.43 254.43 -324.18
NlO max 1002.66 1002.66 832.50 832.50 480.06
NlO min -244.12 244.12 -320.98 320.98 -340.58
Nl max 764.98 764.98 686.89 686.89 1033.13
Nl min -220.95 220.95 -196.10 196.10 532.59
NS8 max 1046.93 1046.93 1158.55 1158.55 1609.73
NS8 min -357.45 357.45 -309.73 309.73 451.78
NS9 max 954.19 954.19 1090.17 1090.17 748.25
NS9 min -366.81 366.81 -386.52 386.52 -252.36
I = i i S • I ______________________ _
Hilti PROFIS Engineering 3.0.95
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter:
Item number:
Effective embedment depth:
Material:
Evaluation Service Report:
Issued I Valid:
Proof:
Stand-off installation:
Anchor plateR:
Profile:
Base material:
Installation:
Reinforcement:
Page:
Specifier:
I E-Mail:
Quidel Project Redwood_Concrete -Mar 13, 2024 Date:
KWIK HUS-EZ (KH-EZ) 3/8 (3 1/4)
418058 KH-EZ 3/8"x3 1/2"
hef,act = 2.500 in., hnom = 3.250 in.
Carbon Steel
ESR-3027
4/1/2022 I 12/1/2023
Design Method ACI 318-19 / Mech
eb = 0.000 in. (no stand-off); t = 0.250 in.
I, x IY x t = 1.570 in. x 2.200 in. x 0.250 in.: (Recommended plate thickness: not calculated)
no profile
cracked concrete, 3000, fc' = 3,000 psi; h = 5.000 in.
hammer drllled hole, Installation condition: Dry
tension: not present, shear: not present; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar
Application also possible with KWIK-X 3/8 (2 1/2) hnom1 under the selected boundary conditions.
More information in section Alternative fastening data of this report.
R -The anchor calculation is based on a rigid anchor plate assumption.
Geometry [In.] & Loading [lb, In.lb]
Input data and results must be checked for conformity with the existing conditions and tor plausibility!
PROFIS Engineering ( c) 2003-2024 Hilti AG, FL-9494 Schaan Hilti Is a registered Trademark ot Hilti AG, Schaan
6/26/2024
,:,,s.,
Hilti PROFIS Engineering 3.0.95
www.hilti.com
Company:
Address:
Page:
Specifier:
Phone I Fax: E-Mail:
Design: Quidel Project Redwood_Concrete -Mar 13, 2024 Date:
Fastening point:
1.1 Design results
Case Description
Combination 1
Forces [lb]/ Moments [in.lb]
N = 419; V, = 1,047; Vy= 1,159;
Mx = 0; My = 0; M, = 0;
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of HIIU AG, Schaan
2
6/26/2024
Seismic Max. Util. Anchor[%]
no 51
2
I = i i S _. • -----------------------
Hilti PROFIS Engineering 3.0.95
www.hilti.com
Company:
Address:
Page:
Specifier:
3
Phone I Fax:
Design:
I Quidel Project Redwood_Concrete -Mar 13, 2024
E-Mail:
Date: 6/26/2024
Fastening point:
2 Proof I Utilization (Governing Cases)
Design values [lb) Utlllzatlon
Loading Proof Load Capacity PN t llv (%] Status
Tension Concrete Breakout Failure 419 2,392 18 / -OK
Shear Steel Strength 1,562 3,111 -/ 51 OK
Loading PN llv r;. Utilization llN,v [%] Status
Combined tension and shear loads 0.175 0.502 5/3 38 OK
3 Warnings
Please consider all details and hints/warnings given in the detailed report!
Fastening meets the design criteria!
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti Is a registered Trademarl< of Hilti AG, Schaan
3
I = i i 5 • i ______________________ _
Hiltl PROFIS Engineering 3.0.95
www.hilti.com
Company:
Address:
Page:
Specifier:
Phone I Fax: I E-Mail:
Design: Quidel Project Redwood_Concrete -Mar 13, 2024 Date:
Fastening point:
4 Alternative fastening
4.1 Alternative fastening data
Anchor type and diameter:
Item number:
Effective embedment depth:
Material:
Evaluation Service Report:
Issued I Valid:
Proof:
Stand-off installation:
Anchor plateR:
Profile:
Base material:
Installation:
Reinforcement:
KWIK-X 3/8 (2 1/2) hnom1
418057 KH-EZ 3/8"x3" (element)/ 2346658 KHC 3/8"
SMALL (capsule)
hef,opti = 2.500 in. (hef,limlt = 3.000 in.), hnom = 2.500 in.
Carbon Steel
ESR-5065
1/1/2023 I 12/1/2023
Design Method ACI 318-19 / Chem
eb = 0.000 in. (no stand-off); t = 0.250 in.
I, x ly x t = 1.570 in. x 2.200 in. x 0.250 in.; (Recommended plate thickness: not calculated)
no profile
cracked concrete, 3000, fc' = 3,000 psi; h = 5.000 in., Temp. short/long: 32/32 °F
hammer drilled hole, Installation condition: Dry
tension: not present, shear: not present; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar
Max. Utilization with KWIK-X 3/8 (2 1/2) hnom1: 51 %
Fastening meets the design criteria!
Input data and results must be checked for confonmity with U1e existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
6/26/2024
4
1:115;.1
Hilti PROFIS Engineering 3.0.95
www.hilti.com
Company:
Address:
Page:
Specifier:
5
Phone I Fax:
Design:
I
Quidel Project Redwood_Concrete -Mar 13, 2024
E-Mail:
Date: 6/26/2024
Fastening point:
5 Remarks; Your Cooperation Duties
Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each
case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data
or programs, arising from a culpable breach of duty by you.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineenng ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilli is a registered Trademark of Hiltl AG, Schaan
5