HomeMy WebLinkAboutCD 2021-0002; SD07644 BANK OF AMERICA; Consistency Determination0 (E) BUILDING
0 (E) T-MOBI LE 4' -11 " PANEL ANTENNA TO BE REMOVED
AND REPLACED: (1) PER SECTORS 'A' & 'c', (2) TOTAL tp ·Mobile®· 0 (E) T-MOBIL E FRP BOX TO RE MAIN WITH VENTS AT ■
TOP, BOTTOM AND BOTH SIDES: (2) PER SECTORS
'A' & 'c', (1) PER SECTOR 'B', (5) TOTAL
0 (E) T-MOBILE 6' -0" PANEL ANTENNA TO REMAIN;
(1) PER SECTOR 'A', (1) TOTAL
0 (N) T-MOBI LE 2 ' -9" PANEL ANTENNA MOUNTED ON (N) @ WALL MOUNT; ( 1) PER SECTO R, (3) TOTAL 1
@ smartlink NOTE:
1. NEW PANEL ANTENNAS AND ALL MOUNTING HARDWARE TO
BE PAINTED TO MATCH EXISTING STRUCTURE IF REQUIRED.
VERIFY PAINT MANUFACTURER AND FINISH WITH OWNER.
KEYNOTES:
M SQUARfc-~~
WIRELESS
1317 CALLE AVANZADO
SAN CLEMENTE CA 92873 (949) 391~
3 4 2 3 1
~ TOP OF EXISTING BU ILDING DRAWN BY: CP
±32' -6" A.G.L. /
>< 1/ I ~ ~
~-
,.1. TOP OF EX ISTING T-MOBILE PANEL ANTENNAS CHECKED BY: MM
Y ±25 -0" A.G.L.
~ TOP OF EX ISTING T-MOB ILE PANEL ANTENNAS
'\ ±24' -6" A.G.L. /I½ Bt /I
~ RAD CENTER OF EX ISTING T-MOBILE PANEL _AN TENNAS _ t ~/ Bl II II l~I II II I I II II I I II II I I II II II II II J I II II I [ II II I 17 II I n[ II l 22'-0" A.G.L.
~I l~I I I I I I ~
0 11/25/2020 100% CD'S FO R SUBMITTAL
B 11/10/2020 100% CD'S FOR REVIEW
A 10/2612020 90% CD'S FOR REVIEW
REV DATE DESCRIPTION
~ GROUND LEVEL
Q' -0" AGL
~11,oFESS/01\<~
r,,'J 0, ~-WI/~,/ 0:,,
,;}' ""' ,,.0 Q K D ~ ~
EXISTING NORTH ELEVATION 24"x36" SCALE: 1/8" • 1'-0" O" 4' 8' 16' 1 !!2-i"l'l
~ ■ -I ~/J 5°l ~ % 11"x17" SCALE: 114" • 1'-0" •
-V C,,,U ~ CJV\I. a'<,~ '
f°OFC~L\~
3 4 5 3 1 DATE SIGNED: I 1/25/2020
Loyall A. Wharton, P.E.
Professional Engineer License: #CS0547
~ TOP OF EXIST ING BUILDING Expiration Date: 06-30-2021
±32' -6" A.G.L. /
>< 1/ I -~
~-
-'-TOP OF EXIST IN G T-MOB ILE PANEL ANTENNAS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS T ±25 -0 A.G.L. ~H EY ARE ACTING UNDER THE DIRECTION OF A LICENSEC
~ TOP OF NEW T-MOBILE PANEL ANTENNAS PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT.
±23' -5" A.G.L. \ 1.ai/ / I,.,,_
~ RAD CENTER OF NEW & EXISTING T-MOBILE PANEL ANTENNAS
~nl )'.;
II Ill I II II I I II II I I II II II II II I I II II I I II II I I II II I I II II I
22' -0" A.G.L. l~n ANCHOR
SITE ID: SD06744 Z'.
l~I I I I ~ SD744 BANK OF AMERICA
7700 EL CAMINO REAL
CARLSBAD, CA 92009
ROOFTOP
SHEET TITLE
ELEVATIONS
~ GROUND LEVEL
Q' -0" AGL
SHEET NUMBER
A-4
NEW NORTH ELEVATION 24"x36" SCALE : 118" • 1'-0" O" 4' 8' 16' 2 11"x17" SCALE: 114" • 1'-0" ~ --I ■
,,
0 (E) BU ILDING
0 (E) T-MOBILE FRP BOX TO REMAIN WITH VENTS AT
TOP, BOTTOM AND BOTH SIDES: (2) PER SECTORS tF ·Mobile®· 'A' & 'C', (1) PER SECTOR 'B', (5) TOTAL
0 (E) T-MOBILE 6'-0" PANEL ANTEN NA TO REMAIN; ■
(1) PER SECTOR 'A ', (1) TOTAL
@ smartlink NOTE:
1, NEW PANEL ANTENNAS AND ALL MOUNTING HARDWARE TO
BE PAINTED TO MATCH EXISTING STRUCTURE IF REQUIRED.
VERIFY PAINT MANUFACTURER AND FINISH WITH OWNER.
KEYNOTES:
SQUARi!D~~ M
WIRELESS
1387 CALLE AVANZADO
SAN CLEMENTE CA 92673 (949) 391-6824
1 3 2
TOP OF EXISTING BUILDING $
±32' -6" A.G.L.
DRAWN BY: CP
~ --~ CHECKED BY: MM
l)' TOP OF EXISTIN G T-MOB ILE PANEL ANTENNAS $
It
/ ±25' -0" A.G.L.
P, __ _ RAD CENTER OF EXISTING T-MOBILE PANEL ANTENNAS $
[ll] lIIJ lJlTII II lJ ! [I] [ _f II IJ 22'-Q" A.G.L. ;,{
Ll
L L,
-1/ 0 11/25/2020 100% CD'S FOR SUBMITTAL
B 11/10/2020 100% CD'S FOR REVIEW
A 10/26/2020 90% CD'S FOR REVIEW
'
IK ~ REV DATE DESCRIPTION
/i Ii I GROUND LEVEL $
o'-o" AGL
~l'-0' ESSto,v4 /i7 0-r,,. W1-t4,/ <':f, $ c,,I' "o G' ~ 0 -;,i;. ~
EXISTING EAST ELEVATION 24"x36" SCALE: 1/8" = 1'-0" O" 4' 8' 16' 1 !!?...., ,. {'fl
~ ~ -I .~/2 5~··t ~ 11"x17" SCALE: 1/4" = 1'-0" ■
~-c~v,:~~(<,~ ~ J
l: OF CP.\.I'<
1 3 2 DATE SIGNED: 11/25/2020
Loyall A. Wharton, P.E.
TOP OF EXISTING BUILDI NG $
Professional Engineer License: #C50547
Expiration Date: 06-30-2021
~ ±32' -6" A.G .L.
~ -~ ~ IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS
'j TOP OF EXISTING T-MOBILE PANEL ANTENNAS $
!THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED
PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT.
/
/7'
±25' -0" A.G.L.
·'J u __ _ RAD CENTER OF EXISTING T-MOB ILE PANEL ANTENNAS $
IT]_] [I□ [_ _ I[ _J _______ II IIJ [ ll_ JlJ ITIJ ·1 (1,
,1/1, 22' -0" A.G.L. ANCHOR .t],
'/ SITE ID: SD06744
~
SD744 BANK OF AMERICA ~
1/ 7700 EL CAMINO REAL
CARLSBAD, CA 92009
ROOFTOP
II I
IK ~ SHEET TITLE
ELEVATIONS
GROUND LEVEL$
o'-o" AGL
SHEET NUMBER
A-5
NEW EAST ELEVATION 24"x36" SCALE: 1/8" = 1'-0" O" 4' 8' 16' 2 11"x17" SCALE : 1/4" = 1'-0" II" --I ■·,
0 (E) BU ILD ING
0 (E) T -MOBILE FRP BOX TO REMAIN WITH VENTS AT
TOP, BOTTOM AND BOTH SIDES; (2) PER SECTORS ~ ·Mobile@· 'A' & 'C', (1) PER SECTOR 'B', (5) TOTAL
■ 0 (E) T-MOBILE 8' -0" PA NEL ANTENNA TO REMAIN;
(1) PER SECTORS 'B' & 'C ', (2) TOTAL
0 (N) T-MOBILE FRP SCREEN BOX MOUNTED ON ®8 (E) WALL WITH VENTS AT TOP, BOTTOM AND '
BOTH SIDES; (1) PER SECTOR 'B', (1) TOTAL D-1
0 (N) T-MOBILE 2' -9" PANEL ANTENNA MOUNTED ON (N) @ WALL MOUNT; (1) PER SECTOR, (3) TOTAL 1
@ smartlink NOTE:
1. NEW PANEL ANTENNAS AND ALL MOUNTING HARDWARE TO
BE PAINTED TO MATCH EXISTING STRUCTURE IF REQUIRED.
VERIFY PAINT MANUFACTURER AND FINISH WITH OWNER.
KEYNOTES:
M SQUAR~~~
WIRELESS
1387 CALLE AVANZADO
SAN CLEMENTE CA 92673 (949) 391-
2 3 3 2 1
Iii' TOP OF EXISTING BUILDING DRAWN BY: CP
±32' -6" A.G.L.
~ -~ CHECKED BY: MM
Iii' TOP OF EXIST ING T-MOBILE PANEL ANTENNAS ~ ±24' -7" A.G.L. \ '
0 1,
I,
:,,
II II I I II II J I II II I
Iii' RAD CENTER OF EX ISTING T-MOBILE PANEL ANTENNAS ___ ;;t ~~I II II II II II II II I I II IIJ[J II I l JLJIJ I II II i I 11/1 20' -7" A.G.L. I"} 1/1 v -
I~
,;!' .::,4,
0 11/25/2020 100% CD'S FOR SUBMITTAL
B 11/10/2020 100% CD'S FOR REVIEW
A 10/26/2020 90% CD'S FOR REVIEW
/ ~ REV DATE DESCRIPTION
Iii' GROUND LEVE L \ I
o'-o" AGL
V
~l'-or Ess,o,.,4 r:fJ >,>, r,,. Wf/411/ ~1' Afs-~ ~%
24"x36" SCALE: 1/8" = 1'-0" O" 4' 8' 16' 1 !!:! -~ ~ EXISTING SOUTH ELEVATION I"' ■ -I ~ll:'52 :I g; 11"x17" SCALE: 1/4" = 1'-0" ■
l --~u -..,, u
u''al: CIV\\..,(1:-._~ I: OF GP.\.\~
2 3 3 2 4 5 1 DATE SIGNED: 11 /25/2020
Loyall A. Wharton, P.E.
Professional Engineer License: #C50547 Iii' TOP OF EX ISTING BUILD ING Expiration Date: 06-30-2021
±32'-6" A.G.L. ~ ~ IT IS A VIOlATION OF lAW FOR ANY PERSON, UNLESS Iii' TOP OF EXISTING T-MOB ILE PANEL ANTENNAS ~HEY ARE ACTING UNDER THE DIRECTION OF A LICENSEC ±24' -7" A.G.L. \ ~ PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Iii' TOP OF NEW T-MOBILE PANEL ANTENNAS ~; I'/'. \ 1:1/,,.:
±22'-0" A.G.L. /~,; I m II II II II II II II 1~1-~t ll lllfl 1
r
II II l ITO [[TI l II Ill I II L 1
Iii' RAD CENTER OF NEW T -MOBILE PANEL ANTENNAS ____ u
I
ANCHOR 20' -7" A.G.L. v( SITE ID: SD06744 ' %½¢, i/i ~~ SD744 BANK OF AMERICA IIL I/ ,
7700 EL CAMINO REAL
CARLSBAD, CA 92009
ROOFTOP
/ \ SHEET TITLE
\ I/ ELEVATIONS Iii' GROUND LEVEL
o'-o" AG L
V
SHEET NUMBER
A-6
24"x36" SCALE: 1/8" = 1'-0" O" 4' 8' 16' 2 NEW SOUTH ELEVATION I"' ■ -I 11"x17" SCALE: 1/4" = 1'-0" •
-----
0 (E) BU ILDING
0 (E) T-MOBILE 4' -11" PANEL ANTENNA TO BE REMOVED
AND REPLACED; (1) PER SECTORS 'A' & 'C', (2) TOTAL t"F ·Mobile®· 0 (E) T-MOBILE FRP BOX TO REMAIN WITH VENTS AT ■
TOP, BOTTOM AND BOTH SIDES; (2) PER SECTORS
'A' & 'C', (1) PER SECTOR 'B', (5) TOTAL
0 (E) T-MOBILE 8 ' -0" PANEL ANTENNA TO REMAIN;
(1) PER SECTORS 'B' & 'C', (2) TOTAL
0 (N) T-MOBILE 2' -9" PANEL ANTENNA MOUNTED ON (N) @ WALL MOUNT; ( 1) PER SECTOR, (3) TOTAL 1
@ smartlink NOTE:
1, NEW PANEL ANTENNAS AND ALL MOUNTING HARDWARE TO
BE PAINTED TO MATCH EXISTING STRUCTURE IF REQUIRED.
VERIFY PAINT MANUFACTURER AND FINISH WITH OWNER.
KEYNOTES:
SQUAR~~~ M
WIRELESS
1387 CALLE AVANZADO
SAN CLEMENTE CA 92873 (949) 391-e824
1 2 3 3 4 4 3
TOP OF EXISTING BU ILDING $ DRAWN BY: CP
±32' -6" A.G.L.
// ~ I \ -~~ ~ I \ TO P OF EXISTI NG T-MOBILE PANEL ANTEN NAS ..._ CHECKED BY: MM
±24 -7 A.G.L . ..,.
TOP OF EX ISTING T-MOBILE PANEL ANTENNAS $ /'.'/ SAN IJIEGurro INSUR,\NCE [7' /\, ·,) / v.: 1/, & SINANCIAI SFRV!CES %"r ±23'-1" A.G.L.
/x U,:
I ll ][] [[□~ )1/t [[IJ [ II IIJ I II II J 1/1 _ RAD CENTER OF EXISTI NG T-MOBILE PANEL, AN;ENNAS $ ·1 ,1
YV/;:;,;y I /i 20 - 7 A.G.L.
I t "/'.'.,( l_
};4 :k ,..__ //. _L
o 11/25/2020 100% CD'S FOR SUBMITTAL
B 11 /10/2020 100% CD'S FOR REVIEW
A 10/26/2020 90% CD'S FOR REVIEW
REV DATE DESCRIPTION
GROUND LEVEL$
o'-o" AGL
~l',oFESS/Ql\'4
1<,<J »-/>,. W H~ ( <'1<
$ ""' "o "' ,i..;:; 0 ~ ~
EXISTING WEST ELEVATION 24"x36" SCALE: 1/8" = 1'-0" O" 4' 8' 16' 1 :12-,-{(I
~ ,. -I ~ bl) 5~· ~I \J; 11"x17" SCALE: 1/4" = 1'-0" ■
,l --T 14) ~ CIV\\.. 0'<,~~ -
f:QF CAI-I'<
1 5 3 3 4 4 3 DATE SIGNED, 11 /25/2020
Loyall A. 'Wharton, P .E.
TOP OF EXISTING BUILDING $
Professional Engineer Llcense: #C50547
Expiration Date: 06-30-2021
±32'-6" A.G.L.
// ~ I \ ~ ~~ ~ I \ TOP OF EXISTI NG T-MOBILE PANEL ANTENNAS -" IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ±24 -7" A.G.L . ..,. HEY ARE ACTING UNDER THE DIRECTION OF A LICENSED
PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT.
1/,/
m
// -TOP OF NEW T-MOBILE PANEL ANTENNAS $ SAN DIEGUITO INSURANCE / _/ /,I~ & J,lJ<.-\NC\Al · SER\~tl'S ({ ±22' -0" A.G.L.
'f~~ ~½ r1' [ITJ ITTI [] J J [_O __ J [TI J A); RAD CENTER OF NEW & EXISTING T-MOBILE PANE~ENNAS $ ANCHOR ~} ~ r , 20 -7 A.G.L.
/~ t//4 ~' SITE ID: SD06744 , --::,,.,,, z:: SD744 BANK OF AMERICA
7700 EL CAMINO REAL
CARLSBAD, CA 92009
ROOFTOP
SHEET TITLE
ELEVATIONS
GROUND LEVEL $
0'-0" AGL
SHEET NUMBER
A-7
NEW WEST ELEVATION 24"x36" SCALE: 1/8" = 1'-0" O" 4' 8' 16' 2 11"x17" SCALE: 1/4" -1'-0" ~ --I ai"'