HomeMy WebLinkAbout2087 WESTWOOD DR; ; CBR2023-4083; PermitBuilding Permit Finaled
Residential Permit
Print Date: 03/12/2025
Job Address:
Permit Type :
Parcel#:
Valuation:
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition:
Sprinkled:
Project Title:
2087 WESTWOOD DR, CARLSBAD, CA 92008-1143
BLDG-Residential Work Class:
1671800700 Track#:
$49,567.08 Lot#:
Project#:
Plan#:
Construction Type:
Orig. Plan Check#:
Plan Check #:
Addition
Description: MUNDAY: NEW 236 SQ FT ADDITION/ REMODEL KITCHEN AND NEW MUD ROOM
Applicant:
A DESIGN
ALISA EICHELBERGER
3505 TRIESTE DR
CARLSBAD, CA 92010-2840
(760) 889-8931
FEE
BUILDING PLAN CHECK
BUILDING PLAN REVIEW -MINOR PROJECTS (LOE)
BUILDING PLAN REVIEW -MINOR PROJECTS (PLN)
581473 -GREEN BUILDING STATE STANDARDS FEE
SFD & DUPLEXES
STRONG MOTION -RESIDENTIAL (SMIP)
SWPPP INSPECTION TIER 1 -Medium BLDG
SWPPP PLAN REVIEW TIER 1 -Medium
Total Fees: $2,826.59 Total Payments To Date: $2,826.59
Permit No:
Status:
(cityof
Carlsbad
CBR2023-4083
Closed -Finaled
Applied: 08/28/2023
Issued : 11/21/2023
Finaled Close Out: 03/12/2025
Final Inspection: 11/04/2024
INSPECTOR: Alvarado, Tony
Balance Due:
de Roggenbuke, Dirk
AMOUNT
$813.15
$197.00
$104.00
$2.00
$1,330.00
$6.44
$292.00
$82.00
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are he reby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 / 442-339-2719 I 760-602-8560 f / www.carlsbadca.gov
(_ Cicyof
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
8-1
Plan Check
Est. Value
PC Deposit
Date
CeiP--1.023 ~YDj3
,~13 , 15
Job Address to~ 7 w ts+woa d 1><1 Ve,, Unit: __ .APN: )lei 7 _,' & 0-o 1-00
CT/Project#:._______________ . ____ vearBuilt: l9'lo g
BRIEF DEscR1Pr10N oF woRK= t-Jw CAolcL-h~ -h-, ,'v\vlu.rle.... od. e -ecJ. --.--------'-=--~_.__-I--"--_-" ____ _
New SF: Living SF, iz (Q, Sfoeck SF, ___ Patio SF, ____ Garage SF __ _
Is this to create an Accessory Dwelling Unit? O Y O N New Fireplace? O YO N, if yes how many? ___ _
D Remodel: ____ SF of affected area Is the area a conversion or change of use? O YO N
□ Pool/Spa: ____ .SF Additional Gas or Electrical Features? ___________ _
0Solar: ___ KW, ___ Modules, Mounted:QRoofQGround, Tilt: 0Y0 N, RMA: OY ON,
Battery:OYO N, Panel Upgrade: OvON Electric Meter number: -----------0th er:
DESIGN PROFESSIO~Al / , ~ l "~'°)tONTRACTOR OF RECORD
Name: J-J:>e$hV\ l A'l'isA. -et~ _g,usiness Name:. _____________ _
Address: ~Jij; 5 ~t:! ~ 5-j-e.. 'br,v Address: _______________ _
City: CM:/< be--d,. State: CA-Zip: 1 Z-OtO City: ______ State:. ____ Zip: _____ _
Phone: 1.1..e...Q...;;,~~q -3 "I ~ I Phone:
Email: 1dfs;&ades1311-5"1Q(2• lQfY\ Email: _______________ _
Architect State License:__________ CSLB License #:. ______ Class:. ______ _
Carlsbad Business License # (Required): ______ _
APPLJCANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information of the plans is accurate. I
agree to comply with all City ordinances and State lows relating to building construction.
NAME (PRINT}:A:/is A_ /3tu, dbu gifs1GN:
1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339·2719
~ DATE, If /ulz?
Email: C:ng@c!rlsbadca.gov
REV. 04122
THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _
A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING
THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE.
(OPTION A): LICENSED CONTRACTOR DECLARATION:
I herebyaf firm underpenal tyof perjurythat I am licensed underprov;s;onsof Chapter 9 ( commendng with Section 7000) of Division 3
of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the
following declarations (CHOOSE ONE):
D I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued. PollcyNo .. _________________________________________ _
-OR-
DI have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued.
My workers' compensation insurance carrier and policy number are: Insurance Company Name: -----------------------•
Polley No. ___________________________ Expiration Date:----------------•
-OR-
D Certificate of Exemption: I certify that In the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful and shall subject an employer to
criminal penalties and clvll fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code,
interest and attorney's fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name: ______________________ Lender'sAddress: _____________________ _
CONTRACTOR CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and
utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans Inconsistent with the site plan are
not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show
the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utlllties. The existing and proposed
use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation.
All improvements existing on the property were completed in accordance with all regulations In existence at the time of their construction, unless otherwise noted.
NAME (PRINT): _________ SIGNATURE: _________ DATE: _____ _
Note: If the person signing above Is an authorized agent for the contract Id I tter of authorization on contractor letterhead.
-OR-
(OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or Improves thereon, and who does such
work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement Is sold
within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
-OR-
°'iv(, .as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
~ractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
-OR-
D I am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
AND,
~RM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed
contractors. I understand that a copy of the applicable law, Section 7044of the Business and ProfessionsCode, is available upon request when this application is
submitted orat the following Web site: http://www.leginfo.ca.govlcalaw.html.
OWNER CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility
easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans Inconsistent with the site plan are not approved
for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct
dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each
building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All
Improvements existing on the property were completed In accordance with all regulations in exiMence at the ti f their construction, unless otherwise noted.
NAME (PRINT)·
Note: If the erson sl
163S Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov
2
REV. 04/22
{ City of
Carlsbad
OWNER-BUILDER
ACKNOWLEDGEMENT
FORM
B-61
Development Services
Building Division
1635 Faraday Avenue
442-339-2719
www .carlsbadca.gov
OWNER-BUILDER ACKNOWLEDGMENT FORM
Pursuant to State of California Health and Safety Code Section 19825-19829
To: Property Owner
An application for construction permit(s) has been submitted in your name listing you as the owner-builder of the
property located at:
Site Address '2r0 <is"]
The City of Carlsbad ("City") is providing you with this Owner-Builder Acknowledgment and Verification form
to inform you of the responsibilities and the possible risks associated with typical construction activities issued
in your name as the Owner-Builder.
The City will not issue a construction permit until you have read and initialed your understanding of each
provision in the Property Owner Acknowledgment section below and sign the form. An agent of the owner
cannot execute this notice unless you, the property owner, complete the Owner's Authorized Agent form and
it is accepted by the City of Carlsbad.
INSTRUCTIONS: Please read and initial each statement below to acknowledge your understanding and
verification of this information by signature at the bottom of the form. These are very important construction
related acknowledgments designed to inform the property owner of his/her obligations related to the requested
permit activities.
I. ~ 1 understand a frequent practice of unlicensed contractors is to have the property owner obtain an "Owner•
~r" building permit that erroneously implies that the property owner is providing his or her own labor and
material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries
sustained by an unlicensed contractor and his or her employees while working on my property. My homeowner's
insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of
the limits of my insurance coverage for injuries to workers on my property.
II. ;;,/ I understand building permits are not required to be signed by property owners unless they are responsible
~e construction and are not hiring a licensed contractor to assume this responsibility.
Ill. # I understand as an "Owner-Builder" I am the responsible party of record on the permit. I understand that I
~rotect myself from potential fina ncial risk by hiring a licensed contractor and having the permit filed in his
or her name instead of my own.
IV . '?f I understand contractors are required by law to be licensed and bonded in California and to list their license
~ers on permits and contracts.
Vt understand if I employ or otherwise engage any persons, other than California licensed contractors, and
~tal value of my construction is at least five hundred dollars ($500), including labor and materials, I may be
V.
considered an "employer" under state and federal law.
1 REV.08/20
Owner-Builder Acknowledgement Continued
VI. :ftl,.1 understand if I am considered an "employer" under state and federal law, I must register with the state
and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and
cont ribute to unemployment compensation for each "employee." I also understand my failure to abide by these
laws may subject me to serious financial risk.
VII. ~ I understand under California Contractors' State License Law, an Owner-Builder who builds single-family
residential structures cannot lega lly build them with the intent to offer them for sale, unless all work is performed
by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of
the work is performed under contract with a licensed general building contractor.
VIII. h I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable
~y financial or personal injuries sustained by any subsequent owner(s) which result from any latent
construction defects in the workmanship or materials.
IX. # I understand I may obtain more information regarding my obligations as an "employer" from the Internal
~ue Service, the United States Small Business Administration, the California Department of Benefit
Payments, and the California Division of Industrial Acc idents. I also understand I may contact the California
Contractors' State License Board (CSLB) at 1-800--321-CSLB (2752) or www.cslb.ca.gov for more information
about licensed contractors.
X. #::-1 am aware of and consent to an Owner-Builder building permit applied for in my name, and understand
that I am the party legally and financially responsible for proposed construction activity at the following address:
XI. ;:/J/ I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide
~applicable laws and requirements that govern Owner-Builders as well as employers.
XII. -# I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the
~ation I have provided on this form.
Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who
does not have a license, the Contractor's State License Board may be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court.
It is also important for you to understand that if an unlicensed Contractor or employee of that Individual or firm
is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner-
Builder and wish to hire contractors, you will be responsible for verifying whether or not those contractors are
properly licensed and the status of their workers' compensation coverage.
Before a building permit can be issued, this form must be completed, signed by the property owner and returned
to the City of Carlsbad Building Division.
I declare under penalty of perjury that I have read and understand all of the information provided on this form and that my responses, including my
authority ta sign this form, is true and correct. I am aware that I have the option to consult with legal counsel prior to signing this form, and I have
either (1) consulted with legal counsel prior to signing this form or (2) have waived this right in signing this farm without the advice of legal counsel.
V 4 -Z'3
Date
2 REV. 08/20
PERMIT INSPECTION HISTORY for (CBR2023-4083)
Permit Type: BLDG-Residential Application Date: 08/28/2023
Work Class: Addition Issue Date: 11/21/2023
Status:
Scheduled
Date
Closed -Finaled Expiration Date: 11/04/2024
IVR Number: 51621
Actual Inspection Type
Start Date
Inspection No.
Checklist Item
Are inactives slopes properly
stabilized?
Are areas flatter than 3: 1
covered or protected?
Are sediment controls properly
maintained?
Are erosion control BMPs
functioning properly?
Are natural areas protected
from erosion?
Are perimeter control BMPs
maintained?
Is the entrance stabilized to
prevent tracking?
Have sediments been tracked
on to the street?
Have materials collected
around the storm drains?
Has sediment accumulated on
impervious surfaces?
Are dumpsters and trash
receptacles covered?
Has trash/debris accumulated
throughout the site?
Are all storage areas clean
and maintained?
Are spill kits provided onsite?
Were spills/leaks observed
during the inspection?
Were there any discharges
during the inspection?
Are portable restrooms
properly positioned?
Do portable restrooms have
secondary containment?
Are BMPs stockpiled for
emergency deployment?
COMMENTS
Inspection
Status
Wednesday, March 12, 2025
Owner: CO-OWNERS TREY AND JOANNA
MUNDAY
Subdivision: FALCON HILL UNIT# 3
Address: 2087 WESTWOOD DR
CARLSBAD, CA 92008-1143
Primary Inspector Reinspection Inspection
Passed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Page 6 of 6
PERMIT INSPECTION HISTORY for (CBR2023-4083)
Permit Type: BLDG-Residential Application Date: 08/28/2023 Owner: CO-OWNERS TREY AND JOANNA
MUNDAY
Work Class: Addition Issue Date: 11/21/2023 Subdivision: FALCON HILL UNIT# 3
Status:
Scheduled
Date
11/01/2024
Closed -Finaled Expiration Date: 11/04/2024
IVR Number: 51621
Actual Inspection Type
Start Date
Inspection No.
Checklist Item
Are inactives slopes properly
stabilized?
Are areas flatter than 3: 1
covered or protected?
Are sediment controls properly
maintained?
Are erosion control BMPs
functioning properly?
Are natural areas protected
from erosion?
Are perimeter control BMPs
maintained?
Is the entrance stabilized to
prevent tracking?
Have sediments been tracked
on to the street?
Have materials collected
around the storm drains?
Has sediment accumulated on
impervious surfaces?
Are dumpsters and trash
receptacles covered?
Has trash/debris accumulated
throughout the site?
Are all storage areas clean
and maintained?
Are spill kits provided onsite?
Were spills/leaks observed
during the inspection?
Were there any discharges
during the inspection?
Are portable restrooms
properly positioned?
Do portable restrooms have
secondary containment?
Are BMPs stockpiled for
emergency deployment?
COMMENTS
11/04/2024 BLDG-Final Inspection
Checklist Item
266528-2024
COMMENTS
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
BLDG-SW-Inspection 266727-2024
Inspection
Status
Passed
Passed
Wednesday, March 12, 2025
Address: 2087 WESTWOOD DR
CARLSBAD, CA 92008-1143
Primary Inspector Reinspection Inspection
Passed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Tony Alvarado Complete
Passed
Yes
Yes
Yes
Yes
Yes
Tony Alvarado Complete
Page 5 of6
PERMIT INSPECTION HISTORY for (CBR2023-4083)
Permit Type: BLDG-Residential Application Date: 08/28/2023 Owner: CO-OWNERS TREY AND JOANNA
MUNDAY
Work Class: Addition Issue Date: 11/21/2023 Subdivision: FALCON HILL UNIT # 3
Status: Closed -Finaled Expiration Date: 11/04/2024 Address: 2087 WESTWOOD DR
CARLSBAD, CA 92008-1143 IVR Number: 51621
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector
Date Start Date
Wednesday, March 12, 2025
Checklist Item
BLDG-14
F rame-Stee I-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
Status
COMMENTS
Basics, 2024
1. Phase 2 -kitchen, interior remodel, with
structural removal of existing loadbearing
wall to enlarge kitchen family room.
locations per plan -rough combination
inspection -approved per plan.
BLDG-SW-Inspection 247552-2024 Partial Pass Tony Alvarado
Reinspection Inspection
Passed
Yes
Yes
Yes
Yes
Reinspection Incomplete
Page 4 of 6
PERMIT INSPECTION HISTORY for (CBR2023-4083)
Permit Type: BLDG-Residential Application Date: 08/28/2023 Owner: CO-OWNERS TREY AND JOANNA
MUNDAY
Work Class: Addition Issue Date: 11/21/2023 Subdivision: FALCON HILL UNIT# 3
Status: Closed -Finaled Expiration Date: 11/04/2024
IVR Number: 51621
Address: 2087 WESTWOOD DR
CARLSBAD, CA 92008-1143
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector
Checklist Item
BLDG-Building Deficiency
Status
COMMENTS
Approved, MEPS, gas, plumbing, line under
test, shear walls, roof sheathing nailing,
and footing (interior footings), for mudroom
location (only).
BLDG-13 Shear
Panels/HD (ok to wrap)
245876-2024 Passed Tony Alvarado
Checklist Item
BLDG-Building Deficiency
COMMENTS
Approved, MEPS, gas, plumbing, line under
test, shear walls, roof sheathing nailing,
and footing (interior footings), for mudroom
location (only).
BLDG-15 Roof/ReRoof 245880-2024 Passed Tony Alvarado
(Patio)
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-23
Gas/Test/Repairs
245875-2024 Passed Tony Alvarado
Checklist Item
BLDG-Building Deficiency
COMMENTS
Approved, MEPS, gas, plumbing, line under
test, shear walls, roof sheathing nailing,
and footing (interior footings), for mudroom
location (only).
BLDG-84 Rough
Combo(14,24,34,44)
245701-2024 Partial Pass Tony Alvarado
Checklist Item
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
COMMENTS
Approved, MEPS, gas, plumbing, line under
test, shear walls, roof sheathing nailing,
and footing (interior footings), for mudroom
location (only).
05/06/2024 05/06/2024 BLDG-31 247551-2024 Passed Tony Alvarado
Wednesday, March 12, 2025
Underground/Conduit -
Wiring
Checklist Item COMMENTS
BLDG-Building Deficiency Underground electrical conduit for kitchen
remodel new island.
BLDG-84 Rough
Combo(14,24,34,44)
247397-2024 Partial Pass Tony Alvarado
Reinspection Inspection
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Yes
Yes
Yes
Passed
Yes
Complete
Reinspection Incomplete
Page 3 of6
PERMIT INSPECTION HISTORY for (CBR2023-4083)
Permit Type: BLDG-Residential Application Date: 08/28/2023
Work Class: Addition Issue Date: 11/21/2023
Status: Closed -Finaled Expiration Date: 11/04/2024
IVR Number: 51621
Scheduled Actual Inspection Type Inspection No. Inspection
Date Start Date Status
Checklist Item COMMENTS
Are inactives slopes properly
stabilized?
Are areas flatter than 3:1
covered or protected?
Are sediment controls properly
maintained?
Are erosion control BMPs
functioning properly?
Are natural areas protected
from erosion?
Are perimeter control BMPs
maintained?
Is the entrance stabilized to
prevent tracking?
Have sediments been tracked
on to the street?
Have materials collected
around the storm drains?
Has sediment accumulated on
impervious surfaces?
Are dumpsters and trash
receptacles covered?
Has trash/debris accumulated
throughout the site?
Are all storage areas clean
and maintained?
Are spill kits provided onsite?
Were spills/leaks observed
during the inspection?
Were there any discharges
during the inspection?
Are portable restrooms
properly positioned?
Do portable restrooms have
secondary containment?
Are BMPs stockpiled for
emergency deployment?
02/16/2024 02/16/2024 BLDG-11 239698-2024 Passed
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS
Owner: CO-OWNERS TREY AND JOANNA
MUNDAY
Subdivision: FALCON HILL UNIT# 3
Address: 2087 WESTWOOD DR
CARLSBAD, CA 92008-1143
Primary Inspector Reinspection
Passed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Dirk de Roggenbuke
Passed
Inspection
Complete
BLDG-Building Deficiency 2/16/24 footing/ slab rebar ok hardware ok Yes
Proceed with concrete placement
04/19/2024 04/19/2024 BLDG-12 Steel/Bond 245881-2024 Partial Pass Tony Alvarado Reinspection Incomplete
Beam
Wednesday, March 12, 2025 Page 2 of 6
Building Permit Inspection History Finaled
C cityof
Carlsbad
PERMIT INSPECTION HISTORY for (CBR2023-4083)
Permit Type: BLDG-Residential
Work Class: Addition
Status: Closed -Finaled
Scheduled Actual Inspection Type
Date Start Date
02/14/2024 02/14/2024 BLDG-21
Underground/Underflo
or Plumbing
Checklist Item
Application Date: 08/28/2023 Owner: CO-OWNERS TREY AND JOANNA
MUNDAY
Issue Date: 11/21/2023 Subdivision: FALCON HILL UNIT# 3
Expiration Date: 11/04/2024
IVR Number: 51621
Inspection No. Inspection
Status
239483-2024 Passed
COMMENTS
Address: 2087 WESTWOOD DR
CARLSBAD, CA 92008-1143
Primary Inspector Re inspection
Tony Alvarado
Passed
Inspection
Complete
BLDG-Building Deficiency Yes
BLDG-SW-Inspection 239559-2024 Partial Pass Tony Alvarado Reinspection Incomplete
Wednesday, March 12, 2025 Page 1 of 6
LOVELACE
ENGINEERING
STRUCTURAL ENGINEERING SERVICES
STRUCTURAL CALCULATIONS
DATE:
PROJECT:
DESIGNER:
JOB:
SEPTEMBER 73, 2023
MUNDAY RESIDENCE
2087 WESTWOOD DRIVE
CARLSBAD, CA 92008
A DESIGN
ALISA EICHELBERGER
ALISA@ADESIGN-SHOP.COM
CARLSBAD, CA
]23320
858.535.9lll I fax 858.535.1989 I www.lovelaceeng.com
10509 Vista Sorrento Pkwy, Suite 102 San Diego, CA 92121
LOVELACE
ENGINEERING
STRUCTURAL ENGINEERING SERVICES
10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121
Joa ...123320 -MUNDAY RESIDENCE
SHEET NO. TC-I OF -------
CALCULATED BY ________ L_.D_._ DATE _____ _
CHECKEDBY __________ DATE _____ _
phone 858.535.9111 • fax 858.535.1989 • www.lovelaceeng.com SCALE __________________ _
TABLE OF CONTENTS
Sl.JBJEC T SHEET
DESIGN CRITERIA ...................................................................................................................................................... DC-I
DESIGN LOADS ........................................................................................................................................................... DL-1
VERTICAL ANALYSIS/DESIGN .............................................................................................................................. V-1/1
LATERAL ANALYSIS/DESIGN ............................................................................................................................... L-1/13
FOUNDATIONS / RETAINING HALLS ........................ ,.......................................................................................... F-1/2
STRUCTURAL NOTES/ SCHEDULES/ DETAILS (HHERE APPLICABLE) ........................................... ..
TOTAL
LOVELACE
ENGINEERING
JOB J2332O -MUNDAY RESIDENCE
SHEET NO, DG-I OF -------
CALCULATEDBY _______ L_.D_._ DATE _____ _
STR UCTURAL ENG I NEER I NG SERVICES CHECKED BY __________ DATE _____ _
10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121
phone 858.535.9111 • fax 858.535.1989 • www.lovelaceeng.com SCALE _________________ _
DESIGN CRITERIA
GOVERNING GODE: GBG 2022
GONGRETE: AGI 3I8-ICl
f'e,=25OO psi, NO SPECIAL INSPECTION REQ'D. (U.N.O.)
MASONRY: TMS 402-16 I AGI 530-13
MEDIUM WEIGHT, ASTM GClO, f'm= 1500 psi, SPECIAL INSP. -REQ'D
MORTA'-R: ASTM G21O, f 'e,=I8OO psi, TYPE S
eROUT: ASTM G416, f 'e,=2000 psi
'-REINFORCING STEEL, ASTM A6I5, Fy= 4Oksi FOR # 4 AND SMALLER
ASTM A6I5, Fy= 6Oksi FOR # 5 AND LARGER (U.N.O.)
STRUCTURAL STEEL: AISG 360-16, 15TH EDITION
ASTM A512, Fy= 50 ksl (STEEL SHAPES) U.N.O.
ASTM A5OO, GRADE B, Fy = 46ksl (STRUCTURAL TUBE)
ASTM A53, 6RADE B, Fy= 35ksl (STRUCTURAL PIPE)
ASTM A36, Fy= 36 ksi (PLATES)
BOLTING, A3O1, SINGLE PLATE SHEAR GONN.
WELDING:
WOOD:
GLULAMS,
SOIL,
A325-N, A4ClO-N HIGH STRENGTH, SINGLE PLATE SHEAR GONN.
ElOXX SERIES-TYP., EClO SERIES FOR A6I5 GRADE 60 REBAR
SHOP WELDING TO BE DONE IN AN APPROVED FABRICATOR'S SHOP
FIELD WELDING TO HAVE CONTINUOUS SPECIAL INSPECTION.
NDS-I8
DOUGLAS FIR LARCH
24F-V4 FOR SIMPLE SPAN CONDITIONS
24F-V8 FOR GANTILEVER GONDITION
ALLOWABLE BEARING PRESSURE
ACTIVE SOIL PRESSURE
=1500
=
AT-REST SOIL PRESSURE (RESTRAINED) = __ _
PASSIVE SOIL PRESSURE = __ _
LATERAL EA-RTHQUAKE PRESSURE = __ _
GOEFFIGIENT OF FRICTION = ---
181 EXISTING NATURAL SOIL PER GBG TABLE 1806..2
SOILS REPORT BY:
PROJEG T NUMBER,
DATED:
psf
pGf
pd
pd
pd
LOVELACE
ENGINEERING
Joe J23320 -MUNDAY RESIDENCE
DL-1 OF -------SHEET NO.
CALCULATED BY _______ L_.D_._ DATE _____ _
STRUCTURAL ENGINEERING SERVICES CHECKEDBY __________ DATE _____ _
10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121
phone 858.535.9111 • fax 858.535.1989 • www.lovelaceeng.com SCALE _________________ _
DESIGN LOADS
ROOF
DEAD LOAD:
ROOFING (COMP.SHINGLES) ............................. .
SHEATHING ................................................ .
RAFTER/CEILING JOISTS OR TRUSSES ...................... .
INSULATION ................................................ .
DRYHALL ................................................. .
OTHER (ELEC., MECH., MISC.) ............................... .
TOTAL DEAD LOAD:
LIVE LOAD, (ROOF USE PER IBC TABLE 1601.1)
TOTAL LOAD:
FLOOR
DEAD LOAD,
FLOORING ( CARPET 4 PAD ) ............................ .
DEX-0-TEX ............................................... .
SHEATHING ................................................ .
JOISTS .................................................... .
DRYHALL / STUCCO ....................................... .
OTHER (ELEC., MECH., MISC.) .............................. .
TOTAL DEAD LOAD:
LIVE LOAD: (-RESIDENTIAL USE PER IBC TABLE 1601.1)
TOTAL LOAD:
EXTERIOR HALL
STUDS ..................................................... .
DRYHALL ................................................. .
INSULATION ................................................ .
EXTERIOR FINISH (STUCCO) .............................. .
OTHER (MISC.) ............................................ .
TOTAL LOAD:
INTERIOR HALL
STUDS ..................................................... .
DRYHALL ................................................. .
OTHER (MISC.) ............................................ .
TOTAL LOAD:
4.0 psf
1.5
3.5
1.5
2.5
1.0
14.0 psf
20.0psf
34.0psf
5.0 psf
.0
2.0
3.5
2.5
2.0
15.0 psf
40.0f25F
55.0 psf
1.0 psf
2.5
1.5
10.0
1.0
16.0 psf
I.Opsf
5.0
1.0
1.0 psf
+ SOLA-R
4.0
18.0 psf
20.0 psf
38.0psf
DECK/OTHER
2.5 psf
2.5
2.0
3.5
10.0
4.5
25.0 psf
60.0 f25F
85.0psf
V-1
~~ LOVELACE
ENGINEERING
Joe J23320 -MUNDAY RESID ENCE
~moo ~I ~ -------
CALCULATED BY ________ L_.D_._ DATE _____ _
STRUCTU RAL ENGINEERING SERVICES CHECKEDBY __________ DATE _____ _
10509 Vista Sorrento Parkway, Suite 102, Sa n Diego, CA 92121
phone 656.535.9111 • fax 656.535.1 969 • www.lovelaceeng.com SCALE __________________ _
VERTICAL ANALYSIS/ DESIGN
LEVEL, ROOF
MEMBERS, R AFTERS ci HEADERS ISEE GODE CHECK CALCULATIONS THA T FOLLOW!
MA'RK: -RR-I SPAN= 14 FT. eRID LINE, cgJ FULL SPAN UNIFORM LOAD
WI D = (18 r;2sf)*(4'/2) = 36 D
(plfJ L= (2 0 r;2sf)*(4'/2) -40 Lr, L
W2D= -D
t t (plFJ L= -Lr L
W3D= = D
(plfJ L = = Lr L ,. ~ , ,
Pl D = = D Maximum Reae,tlons (lbs)
(lbsJ L = = Lr L D Lr L
P2 D= = D 'RI~ 210 I~: I I (lbsJ L = -Ir
I USE:
L 'Rr= 210
2 x 10 @ 2 4" 0 .G. OR I-Rm
MA'RK: RH-I SPAN= 6 FT. eRID LINE: I cgJ FULL SPAN UNIFORM LOAD
WI D= (18 f2Sf)*((l4'/2)+2') = 162 D
(plfJ L= (20 f2Sf)*((l4'/2)+2 ') = 180 Lr , L
W2D= -D t t (plFJ L= = Lr L
W3D= -D
(plfJ L= = Lr I. I L , .,
Pl D= -D Maximum Reactions (lbs)
(lbs) L = = Lr L D Lr L
P2 D = -::~ ;~~ I ;:~1 I (lbs) L= -Lr
I USE: 4 x b OR I -Rm
MARK: RH-2 SPAN= 3 FT. GRID LINE, 2 cgJ FULL SPAN UNIFORM LOAD
WI D = (18 r;2sf)*((l4'/2)+2') -16 2 D
(plfJ L = (20 f2Sf)*((l4'/2)+2') = 180 Lr, L
W2 D= (18 r;2sf)*(2 4'/2) -2 16 D
f t (plfJ L = (20 r;2sf)*(24'/2) =240 Lr, L
W3 D= -D
(plfJ L = = Lr L I. t , 4
Pl D= -D Maximum 'Reactions (lbs)
(lbs) L = = Lr L D Lr L
P2 D= -D :~ 510 I :~~1 I (lbs) L = -Lr L 510
I USE: 4 x 6 OR I
Project Title:
Engineer:
Project ID:
Project Descr:
Wood Beam
MUNDAY RESIDENCE
L.D.
J23320
V-2
Project File: J23320 -VERTICAL.ec6
UC#: KW--0601 3959, Build:20.23.05.25
DESCRIPTION: RR-1
Lovelace Engineering, Inc. (c) ENERCALC INC 1983-2023
CODE REFERENCES
Calculations per NOS 2018, IBC 2021, ASCE 7-16
Load Combination Set : IBC 2021
Material Properties
Analysis Method : Allowable Stress Design
Load Combination : IBC 2021
Wood Species
Wood Grade
Douglas Fir-Larch
No.2
Fb +
Fb -
Fe -Prll
Fe -Perp
Fv
Ft
Beam Bracing Beam is Fully Braced against lateral-torsional buckling
D 0.036 Lr 0.04
£ 2x10
Span = 14.0 ft
900 psi
900 psi
1350 psi
625 psi
180 psi
575 psi
E : Modulus of Elasticity
Ebend-xx 1600ksi
Eminbend -xx 580ksi
Density 31.21 pcf
Repetitive Member Stress Increase
l
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loading
Uniform Load : D = 0.0180, Lr = 0.020 ksf, Tributary Width = 2.0 ft, (ROOF)
DESIGN SUMMARY Design OK
Maximum Bending Stress Ratio = 0.763 1 Maximum Shear Stress Ratio = 0.237 : 1
Section used for this span 2x10 Section used for this span 2x10
fb: Actual = 1,085.90psi fv: Actual = 53.24 psi
F'b = 1,423.13psi F'v = 225.00 psi
Load Combination +D+Lr Load Combination +D+Lr
Location of maximum on span = 7 .000ft Location of maximum on span = 13.234 ft
Span # where maximum occurs Span# 1 Span # where maximum occurs = Span# 1
Maximum Deflection
Max Downward Transient Deflection 0.220 in Ratio = 764>=360 Span: 1 : Lr Only
Max Upward Transient Deflection O in Ratio = 0 <360 n/a
Max Downward Total Deflection 0.434 in Ratio = 387 >=240 Span: 1 : +D+Lr
Max Upward Total Deflection Qin Ratio = 0 <240 n/a
Maximum Forces & Stresses for Load Combinations
Load Combination
Segment Length V CD CM ct CLx CE Cfu C i Cr M fb F'b V fv F'v
D Only 0.0 0.00 0.0 0.0
Length = 14.0 ft 1 0.523 0.162 0.90 1.00 1.00 1.00 1.100 1.00 1.00 1.15 0.96 536.1 1,024.7 0.24 26.3 162.0
+D+Lr 1.00 1.00 1.00 1.100 1.00 1.00 1.15 0.0 0.00 0.0 0.0
Length = 14.0 ft 0.763 0.237 1.25 1.00 1.00 1.00 1.100 1.00 1.00 1.15 1.94 1,085.9 1,423.1 0.49 53 .2 225.0
+D+0.750Lr 1.00 1.00 1.00 1.100 1.00 1.00 1.15 0.0 0.00 0.0 0.0
Length = 14.0 ft 1 0.666 0.207 1.25 1.00 1.00 1.00 1.100 1.00 1.00 1.15 1.69 948.5 1,423.1 0.43 46.5 225.0
+0.60D 1.00 1.00 1.00 1.100 1.00 1.00 1.15 0.0 0.00 0.0 0.0
Length = 14.0 ft 0.177 0.055 1.60 1.00 1.00 1.00 1.100 1.00 1.00 1.15 0.57 321.7 1,821.6 0.15 15.8 288.0
,,,,, ~ Lovelace Engineering, Inc.
.:::::... 10509 Vista Sorrento Pkwy Suite 102
San Diego, CA 92121
Wood Beam
UC#: KW-06013959, Build:20.23.05.25
DESCRIPTION: RR-1
Project Title:
Engineer:
Project ID:
Project Descr:
Lovelace Engineering, Inc.
MUNDAY RESIDENCE
L.D.
J23320
V-3
Project File: J23320 -VERTICAL.ec6
(c) ENERCALC INC 1983-2023
Vertical Reactions Support notation : Far left is #1 Values in KIPS
Load Combination
on 1tions
Max Upward from Load Combinations
Max Upward from Load Cases
D Only
+D+Lr
+D+0.750Lr
+0.600
Lr Only
Support 1 Support 2
.5 3 .553
0.553 0.553
0.280 0.280
0.273 0.273
0.553 0.553
0.483 0.483
0.164 0.164
0.280 0.280
~ ,J,M ~ Lovelace Engineering, Inc.
t::::::.. 10509 Vista Sorrento Pkwy Suite 102
San Diego, CA 921 21
I Multiple Simple Beam
UC#: KW-06013959, Build:20.23.05.25
Description : ROOF HEADERS
Wood Beam Design: RH -1
BEAM Size : 4x6, Sawn, Fully Unbraced
Project Title:
Engineer:
Project ID:
Project Descr:
Lovelace Engineering, Inc.
MUNDAY RESIDENCE
L.D.
J23320
V-4
Project File: J23320 -VERTICAL.ec6
(c) ENERCALC INC 1983-2023
Calculations per NOS 2018, IBC 2021 , ASCE 7-16
Using Allowable Stress Design with IBC 2021 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir-Larch Wood Grade : No.2
Fb -Tension
Fb -Compr
900 psi Fe -Prll 1350 psi Fv 180 psi Ebend-xx
900 psi Fe -Perp 625 psi Ft 575 psi Eminbend -xx
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.1620, Lr = 0.180 k/ft, Trib= 1.0 ft
Design Summary
Max fb/Fb Ratio =
fb : Actual :
Fb : Allowable :
Load Comb :
Max fv/FvRatio = fv : Actual : Fv : Allowable :
Load Comb :
0.730 • 1 1,059.36 psf at
1,452.09 psi
+D+Lr
0.307: 1 69.05 psi at 225.00 psi
+D+Lr
Q l.r J. Max Reactions (k)
Left Support 0.50 0.54
Righi Support 0.50 0.54
Wood Beam Design : RH-2
3.000 ft in Span # 1
5.560 ft in Span # 1
s. 'ii.. E l:i
ax De ections
Transient Downward 0.068 in
1059 Ratio
Transient Upward
Ratio
LC: Lr Only
0.000 in
9999
LC:
1600 ksi
580 ksi
Density 31.21 pcf
Tota l Downward
Ratio
Total Upward
Ratio
0.131 in
550
LC: +D+Lr
0.000 in
9999
LC:
Calculations per NOS 2018, IBC 2021, ASCE 7-16
BEAM Size :
Wood Species :
Fb -Tension
Fb -Compr
Applied Loads
4x6, Sawn, Fully Unbraced
Using Allowable Stress Design with IBC 2021 Load Combinations, Major Axis Bending
Douglas Fir-Larch Wood Grade : No.2
900 psi Fe -Prll 1350 psi Fv 180 psi Ebend-xx
900 psi Fe -Perp 625 psi Ft 575 psi Eminbend -xx
Beam self weight calculated and added to loads
Unif Load: D = 0.1620, Lr = 0.180 k/ft, Trib= 1.0 ft
Unif Load: D = 0.2160, Lr = 0.240 k/ft, Trib= 1.0 ft
Design Summary
1600 ksi
580ksi
Density 31 .21 pcf
Max fb/Fb Ratio =
fb : Actual :
0.421 • 1 613.70 psf at
1 ,457. 04 psi
+D+Lr
-----------------------
Fb : Allowable :
Load Comb :
Max fv/FvRatio =
fv : Actual :
Fv : Allowable :
Load Comb :
Max Reactions (k)
Left Support Right Support
0.292: 1
65.63 psi at
225.00 psi
+D+Lr
Q l.r J.
0.57 0.63 0.57 0.63
1.500 ft in Span # 1
2.550 ft in Span# 1
s. 'ii.. E l:i
it;;: ~1:;~ ·: -~~ • ~:.~-~=~~: t1: ~; ~ ~ ~ .-:~ :~~5;~· · ~~;,
• ~~• '; ;_:':" ~ ."': ko-:~~ '~, ,. ~. ,._ s
ax De ections
Transient Downward
4x6
3.0 It
0.010 in
Ratio 3632
LC: Lr Only
Transient Upward 0.000 in
Ratio 9999
LC:
Total Downward
Ratio
Total Upward
Ratio
0.019 in
1901
LC: +D+Lr
0.000 in
9999
LC:
LOVELACE
ENGINEERING
STRUCTURAL ENGINEERING SERVICES
10509 Vista Sorrento Parkway, Suite 102, Sa n Diego, CA 92121
phone 858.535.9111 • fax 858.535.1989 • www.lovelaceeng.com
LEVEL, FLOOR
MEMBERS: HEADERS 4 BEAMS
MARK, FH-1 SPAN= 8 FT.
HI D= (18 osf)*(34'/2)
(plf) L = (20 est )*(34 '/2)
H2 D= (15 est)*(2'/2)
(plf) L = ( 40 est )*(2 '/2)
H3 D= (1 6 est )*(9 ')
(plf) L =
Pl D=
(lbs) L=
P2 D=
(lbs) L=
I USE: 4x 12 OR
MARK: FB-1 SPAN= 14 FT.
HI D= (1 8 esf)*(4'/2)
(plf) L= (20 osf)*(4'/2)
H2 D= (15 osf)*(l4'/2)
(plf) L = ( 40 est )*(14 '/2)
H3 D= (16 esF )*(12')
(plf) L=
Pl D=
(lbs) L=
P2 D=
(lbsJ L=
I USE: !2~~" ESL OR
MA-RK: FB-2 SPAN= 5 FT.
HI D= (15 esf)*(28'/2)
(pl f) L = (40 ost )*(28 '!2)
H2 D=
(plf) L=
H3 D=
(plf) L =
Pl D=
(lbs) L=
P2 D=
(lbs) L=
I USE: 4 X 12 OR
V-5
Joa J23320 -MUNDAY -RESIDENCE
SHEET NO. ___________ OF ______ _
CALCUIJ\TEDBY ________ L_._D_. -DATE ______ _
CHECKEDBY __________ DATE ______ _
SCALE ___________________ _
ISEE GODE CHECK CALCULATIONS THAT FOLLOHI
6RID LINE: I 0 FULL SPAN UNIFORM LOAD
= 306 D
-34 0 Lr, L
-15 D
t t = Lr, 40 L
= 144 D
= Lr L I. ~
1 1 -D Maximum Reac.tlons (lbs) -Lr L D Lr L
-D R1= 1890 1360 160
-Ir L Rr= 1890 1360 160
I Rm=
6RID LINE: B 0 FULL SPAN UNIFORM LOAD
-36 D
= 40 Lr L
= 105 D t t = Lr, 280 L
-192 D
= Lr L ,. L " " -D Maximum Reac.tlons (lbs)
= Lr L D Lr L
-D R,= 2460 280 1960
-Ir L Rr= 2460 280 1960
I Rm=
eRID LINE: 0 FULL SPAN UNIFORM LOAD
-210 D
= Lr 560 L
-D t t = Lr L
-D
= Lr L ,. ,.
" .,
= D Maximum Reac.tlons (lbs)
= Lr L D Lr L
-D -R,= 550 1400
-Ir L -Rr= 550 1400
I Rm=
Project Title:
Engineer:
Project ID:
Project Descr:
I Multiple Simple Beam
LIC#: KW-06013959, Build:20.23.08.30 Lovelace Engineering, Inc.
Description : FLOOR HEADERS & BEAMS
Wood Beam Design: FH -1
BEAM Size : 4x12, Sawn, Fully Unbraced
MUNDAY RESIDENCE
L.D.
J23320
V-6
Project File: J23320 -VERTICAL.ec6
(c) ENERCALC INC 1983-2023
Calculations per NDS 2018, IBC 2021, ASCE 7-16
Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir-Larch Wood Grade : No.1
Fb -Tension
Fb -Compr
1,000.0 psi Fe -Prll 1,500.0 psi Fv 180.0 psi Ebend-xx
1,000.0 psi Fe -Perp 625.0 psi Ft 675.0 psi Eminbend -xx
1,700.0 ksi
620.0 ksi
Density 31.210pcf
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.3060, Lr= 0.340 k/ft, Trib= 1.0 ft
Unif Load: D = 0.0150, L = 0.040 k/ft, Trib= 1.0 ft
Unif Load: D = 0.1440 k/ft, Trib= 1.0 ft
Design Summary
Max fb/Fb Ratio =
fb: Actual :
Fb : Allowable :
0.787 · 1 1,057.85 psf at
1,344.01 psi
+D+Lr
4.000 ft in Span # 1
Load Comb :
Max fv/FvRatio =
fv : Actual : Fv : Allowable :
Load Comb :
Max Reactions (k)
Left Support
Right Support
0.422 : 1 95.04 psi at 225.00 psi
+D+Lr
Q J.r
1.89 1.36
1.89 1.36
L
0.16
0.16
Wood Beam Design : FB-1
0.000 ft in Span# 1
.s Yi. .E
8.0 ft
ax De ectIons
I:! Transient Downward 0.045 in Total Downward 0.107 in
Ratio 2151 Ratio 899
LC: Lr Only LC: +D+Lr
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Calculations per NDS 2018, IBC 2021, ASCE 7-16
BEAM Size : 5.25x11.25, Parallam PSL, Fully Unbraced
Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending
Wood Species : iLevel Truss Joist Wood Grade : Parallam PSL 2.0E
Fb -Tension 2,900.0 psi Fe -Prll 2,900.0 psi Fv 290.0 psi Ebend-xx 2,000.0 ksi Density 45.070 pcf
Fb -Compr 2,900.0 psi Fe -Perp 750.0 psi Ft 2,025.0 psi Eminbend -xx 1,016.54 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0360, Lr= 0.040 k/ft, Trib= 1.0 ft
Unit Load: D = 0.1050, L = 0.280 k/ft, Trib= 1.0 ft
Unif Load: D = 0.1920 k/ft, Trib= 1.0 ft
Design Summary
Max fb/Fb Ratio =
fb: Actual :
Fb : Allowable :
0.586 · 1
1,676.48 psf at 7.000 ft in Span# 1
2,861 .01 psi
Load Comb:
Max fv/FvRatio = fv : Actual :
Fv : Allowable :
Load Comb :
Max Reactions (k)
Left Support Right Support
+D+L
0.336: 1 97.30 psi at 13.067 ft in Span# 1
290.00 psi
+D+L
Q Lr
2.46 0.28
2.46 0.28
L
1.96
1.96
.s Yi. E I:!
ax eflections
5.25x11 .25
14.0 ft
Transient Downward 0.195 in
Ratio 860
LC: L Only
Transient Upward 0.000 in
Ratio 9999
LC:
Total Downward
Ratio
Total Upward
Ratio
0.440 in
381
LC: +D+L
0.000 in
9999
LC:
Project Title:
Engineer:
Project ID:
Project Descr:
I Multiple Simple Beam
UC#: KW-06013959, Build:20.23.08.30 Lovelace Engineering, Inc.
Wood Beam Design : FB-2
BEAM Size : 4x12, Sawn, Fully Unbraced
MUNDAY RESIDENCE
L.D.
J23320
V-7
Project File: J23320 -VERTICAL.ec6
(c) ENERCALC INC 1983-2023
Calculations per NDS 2018, IBC 2021, ASCE 7-16
Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending
Wood Species :
Fb -Tension
Fb • Compr
Applied Loads
Douglas Fir-Larch Wood Grade : No.2
900 psi Fe -Pr1I 1350 psi Fv 180 psi Ebend-xx
900 psi Fe -Perp 625 psi Ft 575 psi Eminbend -xx
Beam self weight calculated and added to loads
Unif Load: D = 0.210, L = 0.560 k/ft, Trib= 1.0 ft
1600 ksi
580 ksi
Density 31 .21 pcf
Design Summary D(O 210),1..(0 560)
Max fb/Fb Ratio =
fb : Actual:
0.403 • 1 395.45 psf at
980.66 psi
+D+L
Fb : Allowable :
Load Comb :
Max fv/FvRatio =
fv : Actual:
Fv : Allowable :
Load Comb :
0.258 : 1
46.46 psi at
180.00 psi
+D+L
Max Reactions
Left Support Right Support
(k) Q Lr L
1.40 1.40 0.55 0.55
2.500 ft in Span# 1
4.067 ft in Span # 1
'!:i.. .E l:i
ax e ect1ons
4x12
5.0 ft
Transient Downward 0.012 in
Ratio
Transient Upward
Ratio
5035
LC: L Only
0.000in
9999
LC:
Total Downward
Ratio
Total Upward
Ratio
0.017 in
3622
LC: +D+L
0.000 in
9999
LC:
~ LOVELACE MUNDAY RESIDENCE
ENGINEERING JOANNA & TREY MUNDAY
ITAUCTUAAL INOINlil:AINO 11:AV CCI J23320
SE ISMIC WEIGHT
Level 2 ROOF Typical Plate Ht. (ft.)
Element Type Dead Load (psf) Area (sf)
Diaphragm ROOF 18 1150
Diaphragm
Diaphragm
Dead Load (psf) Length (ft.)
Wall EXTERIOR 16 125
Wall INTERIOR 7 95
Wall
Dead Load ( lbs.)
Misc./ Concentrated
Total Weight (lbs.) 44685 Seismic Weight (lbs.)
Level 1 FLOOR Typical Plate Ht. (ft.)
Element Type Dead Load (psf) Area (sf)
Diaphragm FLOOR 20 960
Diaphragm ROOF 18 1200
Diaphragm
Dead Load (psf) Length (ft.)
Wall EXTERIOR 16 225
Wall INTERIOR 7 130
Wall
Dead Load {lbs.)
Misc./ Concentrated
Total 81390 Seismic Weight
9
Weight
20700
0
0
Weight
18000
5985
0
Weight
0
32692.5
9
Weight
19200
21600
0
Weight
32400
8190
0
Weight
0
73087.5
L-1
L.D.
8/15/2023
Page:
ASCE.
AMERICAN SOCIETY OF CML ENGINEERS
Address:
2087 Westwood Dr
Carlsbad, California
92008
Wind
Results:
Wind Speed
10-year MRI
25-year MRI
50-year MRI
100-year MRI
Data Source:
Date Accessed:
L-2
ASCE 7 Hazards Report
Standard: ASCE/SEI 7-16
Risk Category: 11
Soil Class: D -Default (see
Section 11.4.3)
96 Vmph
66 Vmph
72 Vmph
77 Vmph
82 Vmph
Latitude: 33.16823
Longitude: -117.329546
Elevation: 217.34766516706733 ft
(NAVO 88)
ASCE/SEI 7-16, Fig. 26.5-18 and Figs. CC.2-1-CC.2-4, and Section 26.5.2
Thu Jun 15 2023
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability=
0.00143, MRI= 700 years).
Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2.
https://asce 7hazardtool .online/ Page 1 of 3 Thu Jun 15 2023
ASCE.
AMERICAN SOCIETY OF CML ENGINEERS
Seismic
Site Soil Class:
Results:
Ss
s,
Fa
D -Default (see Section 11.4.3)
1.02
0.372
1.2
So, :
TL :
PGA:
N/A
8
0.447
Fv N/A PGA M : 0.536
S Ms 1.224 F PGA 1.2
S M1 N/A 18 : 1
Sos 0.816 Cv : 1.304
Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8.
Data Accessed: Thu Jun 15 2023
Date Source: USGS Seismic Design Maps
https://asce7hazardtool.online/ Page 2 of 3
L-3
Thu Jun 15 2023
L-4 ASCE.
AMEfllCAN SOCIETY OF a\lll ENGINEERS
The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided "as is" and without warranties of
any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers;
or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from
reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability,
currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement,
affiliation, relationship, or sponsorship of such third-party content by or from ASCE.
ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE 7 Hazard Tool.
https://asce 7hazardtool .online/ Page 3 of 3 Thu Jun 15 2023
-~ LOVELACE ~ ENGINEERING
h i IIUCI UW4L f!fUllfl t.f!MINCJ h~N'WICt.111
MUNDAY RESIDENCE
JOANNA & TREY MUNDAY
J23320
SEISMIC BASE SHEAR II
Level
2
1
Period Calculation
Overall Ht. System
23 All Other Systems
Ts =
T°' = C:;h;i Ta =
TL =
Base Shear
System R
Wood Shear Walls 6.5
Site Class: ~
SOS=~
SDl = 0.478
Sl = I 0.372
Fx = Cvx 'V
ht. (ft.)
13
10
23 ft.
wx (lbs.)
32692.5
73087.5
Vertical Distribution
hx
23
10
Ct X
0.02 0.7S
0.586 s
0.210 s
8 s
Omega Cd
2.5
Cs =
W=
V=
k
1
1
1
4.5 1.0
0.126
105.78 k
13.28 k
Total Base Shear
wx•hxAk Cvx
751927.5 0.507098889
730875 0.492901111
1482802.5
L.D.
8/15/2023
Page:
per ASCE 7, Fig. 22-14
per ASCE 712.8.1.1
Fx
k
6.7 k
6.5 k
Ta = Cthn x
Ta= 0.210
JV= 1.928 FROM TABLES & LINEAR
SM1 = S1 * fV
,,.. SD1/ 's = SDs
SM1 = 0.717
T5 = 0.586 SD1 = C2h)SM1
l.ST5 = 0.878941 SD1 = 0.478
:. Per exception 2 of ASCE 7 -16 section 11.4.8
Ta < l.ST5 so C5 from equation 12.8 -2 can
be used and does not need to be factored.
INTERPOLATION
L-5
I~ LOVELACE PROJECT MUNDAY RESIDENCE
~ ENGINEERING CLIENT JOANNA& TREY MUNDAY
'''""'"' .. ,. ""'" .,.,,,.., JOB NO. J23320 DATE : 06/16/23
Wind Anal sis for Low-rise Buildin , Based on 2018 IBC/ASCE 7-16
INPUT DATA
Exposure category (B, c or D, ASCE 7-16 26.7.3)
Importance factor (ASCE 7-16 Table 1-5-2)
Basic wind speed (ASeE 7-16 26.5. 1 or 2018 IBC)
Topographic factor (ASeE 7-16 26.8 & Table 26.8-1)
Building height to eave
Building height to ridge
Building length
Building width, including overhangs
Overhang sloped width
lw =
V =
Kzt =
he =
hr =
L =
B =
C
1.00
96
for all Category
mph, (154.50 kph)
Flat
ft, (6.10 m)
ft, (7.92 m)
ft, (10.36 m)
ft, (9.14 m)
ft, (0.46 m)
PAGE
DESIGN BY LD.
REVIEW BY
8
Effective area of components (or Solar Panel area)
Oh=
A=
20
26
34
30
LS
12 tt2, <== Overhang? (Yes or No) No
( 1-12 m'J
DESIGN SUMMARY
Max horizontal force normal to building length, L, face
Max horizontal force normal to building length, B, face
Max total horizontal torsional load
12.46 kips, (55 kN), SD level (LRFD level), Typ.
11.04 kips, (49 kN)
Max total u ward force
ANALYSIS
Velocity pressure
qh = 0.00256 Kz Kzt Kd K8 V2
55.9517 ft-kips, (76 kN-m)
17.55 ki s 78 kN
18.53 psf
where: qh = velocity pressure at mean roof height, h. (Eq. 26.10-1 page 268)
Kz = velocity pressure exposure coefficient evaluated at height, h, (Tab. 26.10-1, pg 268)
Ko = wind directionality factor. (Tab. 26.6-1, for building, page 266)
h = mean roof hei ht
0.92
0.85
23.00 ft
L-6
K. = ground elevation factor. (1.0 per Sec. 26.9, page 268) < 60 ft, [Satisfactory]
.._ ___ <_M_l_n.._L..,,_B), [Satisfactory]
(ASCE 7-16 26.2.1)
(ASCE 7-16 26.2.2)
Design pressures for MWFRS
p = qh [(G cp, l-(G cp1 )I
where: p = pressure in appropriate zone. (Eq. 28.3-1 , page 311). Pmln = 16 psf (ASCE 7-16 28.3.4)
G c, 1 = product of gust effect factor and external pressure coefficient, see table below. (Fig. 28.3-1, page 312 & 313)
G c,, = product of gust effect factor and internal pressure coefficient.(Tab. 26.13-1, Enclosed Building, page 271)
0.18 or -0.18
a= width of edge strips, Fig 28.3-1, page 312, MAX[ MIN(0.1 B, 0.1 L, 0.4h), MIN(0.04B, 0.04L), 3] = 3.00 ft
Net Pressures (psf), Basic Load Cases Net Pressures (psf), Torsional Load Cases
Roof angle a = 21.80 Roof angle a = 0.00 Roof angle a = 21 .80
Surface Net Pressure with Net Pressure with Ge,, (+GCp;) (-GC,,) Ge,, (+GC,,) (-GC,,)
Surface Net Pressure with GCp1 (+GC,1) (-GC,,)
1 0.54 6.59 13.26 -0.45 -11.67 -5.00 1T 0.54 1.65 3.31
2 -0.53 -13.12 -6.45 -0.69 -16.12 -9.45 2T -0.53 -3.28 -1.61
3 -0.47 -12.06 -5.39 -0.37 -10.19 -3.52 3T -0.47 -3.02 -1.35
4 -0.42 -11 .10 .4.43 -0.45 -11.67 -5.00 4T -0.42 -2.78 -1.11
5 0.40 4.08 10.75 Roof anole a = 0.00
6 -0.29 -8.71 -2.04
1E 0.78 11 .12 17.79 -0.48 -12.23 -5.56
Surface Net Pressure with Ge,1 (+GC,1 ) (-GC,,)
2E -0.83 -18.69 -12.02 -1.07 -23.16 -16.49 ST 0.40 1.02 2.69
3E -0.66 -15.59 -8.92 -0.53 -13.16 -6.49 6T -0.29 -2.18 -0.51
4E -0.61 -14,66 -7.99 -0.48 -12.23 -5.56
5E 0.61 7.97 14.64
6E -0.43 -11.30 -4.63
Lood Cose A (Transverse) Load Case B (Longitudinal) Load Cose A (Transverse) Load Case B (Longitudinal)
C
L-7
Basic Load Case A (Transverse Direction) Basic Load Case B (Longitudinal Direction)
Area Pressure (kl with Area Pressure (kl with Surface (ft') (+Ge.;) (-Ge.,) Surface (ft') (+Ge.;) (-Gep1)
1 560 3.69 7.42 Poverhang = -12.97 psf 2 452 -7.29 -4.27
2 452 -5.93 -2.92 (ASeE 7-16 28.3.3) 3 452 -4.61 -1.59
3 452 -5.46 -2.44 5 566 2.31 6.09
4 560 -6.22 -2.48 6 566 -4.93 -1.15
1E 120 1.33 2.14 2E 97 -2.25 -1.60
2E 97 -1.81 -1.17 3E 97 -1.28 -0.63
3E 97 -1.51 -0.86 5E 124 0.98 1.81
4E 120 -1 .76 -0.96 SE 124 -1.40 -0.57
r Horiz. 12.71 12.71 r Horiz. 9.62 9.62
Vert. -13.66 -6.86 Vert. -11 .43 -4.30
Min. wind Horiz. 12.51 12.51 Min. wind Horiz. 11 .04 11.04
28.4.4 Vert. -16.32 -16.32 28.4.4 Vert. -16.32 -16.32
Torsional Load Case A (Transverse Direction) Torsional Load Case B (Longitudinal Direction)
Area Pressure (k) with Torsion (ft-k) Area Pressure (k) with Torsion (ft-k) Surface (ft') (+Ge.,) (-Ge.,) (+Ge.,) (-Ge.,) Surface (ft') (+Ge.,) (-Ge.,) (+Ge.,) (-Ge.,)
1 220 1.45 2.92 10 20 2 452 -7.29 -4.27 -4 -2
2 178 -2.33 -1.15 -6 -3 3 452 -4.61 -1 .59 3 1
3 178 -2.14 -0.96 6 2 5 221 0.90 2.38 5 14
4 220 -2.44 -0.98 17 7 6 221 -1.93 -0.45 11 3
1E 120 1.33 2.14 19 30 2E 97 -2.25 -1.60 13 9
2E 97 -1.81 -1.17 -9 -6 3E 97 -1 .28 -0.63 -7 -4
3E 97 -1 .51 -0.86 8 4 5E 124 0.98 1.81 13 24
4E 120 -1.76 -0.96 25 13 SE 124 -1 .40 -0.57 19 8
1T 340 0.56 1.13 -5 -10 ST 345 0.35 0.93 -3 -7
2T 275 -0.90 -0.44 3 1 ST 345 -0.75 -0.18 -5 -1
3T 275 -0.83 -0.37 -3 -1 Total Horiz. Torsional Load, Mr 44.7 44.7
4T 340 -0.94 -0.38 -8 -3
Total Horiz. Torsional Load, Mr 56 56
Design pressures for components and cladding r'r----7' l•r-2~~ ~t-1~3_! ...-----,
p = qh[ (G c.i -(G c.,H 5 i1 I ,---, I I I I I
5 I I --I I I I I I
where: p = pressure on component. (Eq. 30.3-1, pg 334) lo,,~ f I 5 5 ! 1.0f\~ 4 2 I 1 I . I I 2,1 _ 12, 2,1-12,
0 I I ~ I I I ~ I :i: Pmin = 16.00 psf (ASeE 7-16 30.2.2) I I I I IN I 0 I L---'-+-3 I I I I G e . = external pressure coefficient. ~L-----;',...6 .6h c-1---1--1----1-~ see table below. (ASeE 7-16 30.3.2) Walls O.?h .6h Je 2n Jr Jr 2n Jc
O= 21.80 0 Roof 0,1· Roof 9>7•
Effective Zone 1 Zone 1' Zone 2 Zone 2e Zone 2n Zone 2r
Area (112) Ge. -GC, GCp -GCp GCp -GCp GCp -GCp GCp -GCp GC, -GC•
Comp. 12 0.52 -1 .50 ---. 0.52 -1.50 0.52 -2.43 0,52 -2.43
Effective Zone 3 Zone 3e Zone 3r Zone4 Zones
Area (112) GCp -GC• GCp -GC, GC, -GC• GCp -GC, GCp -GCp
12 --0.52 I -2.43 0.52 I -2.82 0,99 -1.09 0.99 -1 .37
Zone 1 Zone 1' Zone 2 Zone 2e Zone 2n Zone 2r
Comp. & Cladding Positive Negative Po5ltiv• Negative Positive Nr,g11tlva Positive Negativ• Positive Negative PosWv• N•a•tfv•
Pressure 16.00 -31 ,13 16.00 -31 .13 16.00 -48.30 16.00 I -48.30
(psi) Zone 3 Zone 3c Zone 3r Zone 4 Zone 5
Posirh,e N~•tlve Positive Nt,g•Uvt Positive Nag•tiv• Positive N9gaf/vt Positive Negative (The Max Pressure
16.00 -48.30 16.00 -55.54 21 .61 -23.46 21.61 -28.76 55.54 psf)
l•8
~ MUNDAY RESIDENCE L.D. LOVELACE JOANNA & TREY MUNDAY 8/15/2023 ENGINEERING
STtlt.CTVtlAI. e.NOIMltRIMQ 'SUlVICl.:1 J23320 Page:
LATERAL STORY FORCES
Seismic
Level Fx (lbs.) Diaphragm Area (sf) ASD Story Load (psf)
0 0.7
2 6734 1150 0.7 4.1
1 6S45 2160 0.7 2.1
Wind
Direction N-S B-0
Force = 11.04 k Pressure = 15.3 psf
Level Ht. length area Trib. Ht. ASD diaph. Load
Ridge/Parapet 6 30 180 3 0.6 plf
2 9 30 270 10.5 0.6 97 plf
1 9 30 270 9 0.6 83 plf
720 sf
Direction E-W 1-4
Force= 12.46 Pressure = 15.3 psf
Level Ht. length area Trib. Ht. ASD diaph. Load
Ridge/Parapet 6 34 204 3 0.6 plf
2 9 34 306 10.5 0.6 96 plf
l 9 34 306 9 0.6 82 plf
816 sf
I~ LOVELACE ~ ENGINEERING
!JTAUCTUtlAl !:N(UNC:l!AINO 5e:,:;v1ces
MUNDAY RESIDENCE Level Name
JOANNA & TREY MUNDAY Level n
123320 Lateral Line
ROOF
2
1
Direction
E-W
L.D.
9/13/2023
Page:
WOOD SHEARWALL ANALYSIS & DESIGN
Area
1
2
3
4
SEISMIC LOAD
sos= 0.816
p = 1.3
Story Load 4.1
SF Factor
1150 1.0
Total/2 = Seismic Load
psf
Load (lbs)
"'ii
Load Type L Worst Case
Load (plf) 96
Length L (ft.) 34
Load L (lbs.) 3271
2357 lbs. Total/2 = Wind Load
ADDITIONAL SEISMIC LOAD ADDITIONAL WIND LOAD
Line
Segment
H
H/L Ratio
Load Ratio
Load E
Adj. Load E
Load W
Adj. Load W
Unit Shear E
Unit Shear W
OTME
OTMW
Wall Weight
Wall UDL
Unit. DL
Concen. DL
CDL lac.
DL Moment
DL Mom. E
DLMom.W
Net OT E
NetOTW
Uplift E
Add. Uplift E
UpliftW
Add. Uplift W
Tot. Uplift E
Tot. UpliftW
HD#
Load (lbs.) Offset Factor Adjust. Load Line Load (lbs.)
Total Add. Load 0
Total Seismic Load = 3064 lbs. Total Wind Load =
SHEAR
1
Max Shear 0 PLF USE# Shear Wall
OVERTURNING
UPLIFT
• -No HD required, by inspection
•• -See Perforated/ Force-Transfer Shearwall calculation
WIND LOAD
Load Type R
Load (plf)
Length R (ft.)
Load R (lbs.)
1635 lbs.
Offset Factor Adjust. Load
Total Add. Load
1635 lbs.
0
Worst Case
96
0
Total Shear
Length (ft.)
0
lbs.
lbs.
lbs.
lbs.
plf
plf
Capacity= 260 pit
#-ft.
#-ft.
psf
plf
pit
lbs.
ft.
#-ft.
#-ft.
#-ft.
#-ft.
#-ft.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
L-9
Byll.tlo
C8C 2306.5
I~ LOVELACE ~ ENGINEERING
STAU C:TURAL ~H<>INfC AINQ $1!~VICCS
MUNDAY RESIDENCE Level Name
JOAN NA & TREY MUN DAY Level n
J2332O Lateral Line
FLOOR
1
A
Direction
N-S
L.D.
9/13/2023
Page;
WOOD SHEARWALL ANALYSIS & DESIGN
Area
1
2
3
4
SEISMIC LOAD
sos = 0.816
p = 1.3
Story Load 2.1
SF Factor
320 1.0
Total/2 = Seismic Load
psf
Load (lbs)
'11
Load Type L Worst Case
Load (plf) 83
Length L (ft.)
Load L (lbs.) 0
339 lbs. Total/2 = Wind Load
ADDITIONAL SEISMIC LOAD ADDITIONAL WIND LOAD
Line
Segment
H
H/L Ratio
Load Ratio
Load E
Adj. Load E
Load w
Adj. Load W
Unit Shear E
Unit Shear W
OTM E
OTMW
Wall Weight
Wall UDL
Unif. DL
Concen. DL
COL loc.
DL Moment
DLMom. E
DLMom.W
Net OT E
Net OTW
Uplift E
Add. Uplift E
UpliftW
Add. Uplift W
Tot. Uplift E
Tot. Uplift W
HD#
Load (lbs.) Offset Factor
Total Add. Load
Total Seismic Load =
1
8
10
1.3
1.00
441
704
503
55
63
Max Shear
4412
7038
16
160
30
6080
2953
3648
1459
3390
182
424
182
424
63
Adjust. Load
0
441 lbs.
SHEAR
PLF I USE#
OVERTURNING
UPLIFT
• • No HD required, by Inspection
••.See Perforated/ Force-Transfer Shearwall calculation
Line Load (lbs.)
Total Wind Load =
1 Shear Wall
WIND LOAD
Load Type R
Load (plf)
Length R (ft.)
Load R (lbs.)
704 lbs.
Offset Factor Adjust. Load
Total Add. Load 0
704 lbs.
Worst Case
83
17
1408
Total Shear
Length (ft.)
8
lbs.
lbs.
lbs.
lbs.
plf
plf
Capacity = 260 plf
#-ft.
#·ft.
psf
plf
plf
lbs.
ft.
#-ft.
#-ft.
#-ft.
#-ft.
#-ft.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
L-10
!lyRaUo
cac 2306.s
8~ L OVELACE ~ ENGINEERING
$TAtJCTURAt.. =.N<JINE£AIMO $1f Pv1ces
MUNDAY RESIDENCE Level Name
JOANNA & TREY MUNDAY Level #
J23320 Lateral Line
FLOOR
1
1
Direction
E-W
L.D.
9/13/2023
Page:
WOOD SHEARWALL ANALYSIS & DESIGN
Area
1
2
3
4
SEISMIC LOAD
sos = 0.816
p = 1.3
Story Load 2.1
SF Factor
320 1.0
660 1.0
Total/2 = Seismic load
pst
Load (lbs)
679 Load Type l Worst Case
1400 Load (pit) 82
0 Length L (ft.) 14
0 Load L (lbs.) 11S4
1039 lbs. Total/2 = Wind Load
ADDITIONAL SEISMIC LOAD ADDITIONAL WIND LOAD
Line
1
Segment
H
H/L Ratio
Load Ratio
Load E
Adj. Load E
Load W
Adj. Load W
Unit Shear E
Unit Shear W
OTM E
OTMW
Wall Weight
Wall UDL
Unit. DL
Concen. DL
CDL loc.
DL Moment
DL Mom. E
DLMom.W
Net OT E
Net OTW
Uplift E
Add. Uplift E
UpliftW
Add. Uplift W
Tot. Uplift E
Tot. Uplift W
HD#
Load (lbs.) Offset Factor
3064 1.00
Total Add. Load
Total Seismic Load =
1
8
8
1.0
1.00
5334
2213
1580
667
198
Max Shear
42675
17701
16
128
105
7456
3622
4474
39053
13227
4882
1653
4882
1653
3
667
Adjust. Load
3064
3064
5334 lbs.
PLF
SHEAR
I USE#
OVERTURNING
UPLIFT
• -No HD required, by inspection
•• -See Perforated/ Force-Transfer Shearwall calculation
line Load (lbs.)
1 1635
Total Wind Load =
5 Shear Wall
WINO LOAD
Load Type R
Load (pit)
Length R (ft.)
Load R (lbs.)
577 lbs.
Offset Factor Adjust. Load
1.0 1635
Total Add. Load 1635
2213 lbs.
Worst Case
82
0
Total Shear
Length (ft.)
8
lbs.
lbs.
lbs.
lbs.
pit
pit
Capacity = 730 plf
#-ft.
#-ft.
psf
plf
plf
lbs.
ft.
#-ft.
#-ft.
#-ft.
#-ft.
#-ft.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
L-11
ByRat!o
cac 230J.!I
I~ LOVELACE ~ ENGINEERING
STAUCTUAI\L !NOINIHe.AtHO $E.PVIC:e:ti
MUNDAY RESIDENCE Level Name
JOANNA & TREY MUNDAY Level#
J23320 Lateral Line
FLOOR
1
2
Direction
E-W
L.D.
9/13/2023
Page;
WOOD SHEARWALL ANALYSIS & DESIGN
Area
1
2
3
4
SEISMIC LOAD
sos= 0.816
p = 1.3
Story Load 2.1
SF Factor
320 1.0
660 1.0
545 1.0
Total/2 = Seismic Load
psf
Load (lbs)
679 Load Type L Worst Case
1400 Load (pit) 82
1156 Length L (ft.) 25
0 Load L (lbs.) 2061
1617 lbs. Total/2 = Wind Load
ADDITIONAL SEISMIC LOAD ADDITIONAL WIND LOAD
Line Load (lbs.) Offset Factor Adjust. Load line Load (lbs.)
Total Add. Load 0
Total Seismic Load= 2103 lbs. Total Wind Load =
SHEAR
Segment 1 2
L 4 8
H 7 7
H/L Ratio 1.8 0.9
Load Ratio 0.33 0.67
Load E 701 1402
Adj. Load E
Load W 536 1072
Adj. Load W 383 766
Unit Shear E 175 175
Unit Shear W 96 96
Max Shear 175 PLF I USE# 1 Shear Wall
OVERTURNING
OTM E 4906 9812
OTMW 3752 7503
Wall Weight 16 16
Wall UDL 112 112
Unit. DL
Concen. DL
COL lac.
DLMoment 896 3584
DL Mom. E 435 1741
DLMom.W 538 2150
Net OT E 4471 8071
Net OTW 3214 5353
UPLIFT
Uplift E 1118 1009
Add. Uplift E
UpliftW 804 669
Add. Uplift W
Tot. Uplift E 1118 1009
Tot. Uplift W 804 669
HD# •• ••
• -No HD required, by inspection
•• -See Perforated/ Force-Transfer Shearwall calculation
WIND LOAD
Load Type R Worst Case
Load (pit) 82
Length R (ft.) 14
Load R (lbs.) 1154
1608 lbs.
Offset Factor Adjust. Load
Total Add. Load 0
1608 lbs.
Total Shear
Length (ft.)
12
lbs.
lbs.
lbs.
lbs.
pit
pit
Capacity= 260 pit
#-ft.
#-ft.
psf
pit
pit
lbs.
ft.
#-ft.
#-ft.
#-ft.
#-ft.
#-ft.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
L-1 2
llvl\atlo
C8C 1306,3
I~ LOVELACE ~ ENGINEERING
:S.TAUCTUIIAL !NOINl!EAINO $E;S:Y'ICC:$
Shear E 2103
Segment Adj. Shear E
Adjust. Shear E 2103
Shear W 1608
Adjust. Shear W 1148
Ll (ft.)
4.0
H above 4.5 ft.
H opening 7 ft.
H below 0 ft.
Total Height 11.S ft.
LI t w
•<plr>
lllllll
OVERTURNING
OTM E
OTMW
Wall Weight
Wall UDL
Uniform DL
DL Moment
DL Moment E
DLMomentW
Net OT E
Net OTW
24181
18491
7
81
285
41119
19974
24671
4207
-6181
I
I
I
I
I
I
I
b.-ft.
b.-ft.
psf
plf
plf
b.-ft.
b.-ft.
b.-ft.
b.-ft.
b.-ft.
MUNDAY RESIDENCE
JOANNA & TREY MUNDAY
J23320
Level Name
Level#
Lateral Line
FLOOR
1
2
FORCE TRANSFER SHEAR WALL
w (ft.)
3.0
V
Strap Force 1
v'
Strap Force 2
L2 r
J l
j
SHEAR
Net shear to segments, non-adjusted for segment ratio
Segment-adjusted shear per NDS 4.3.4
adjusted for overall H/l ratio of Force-Transfer Shear Wall
Net shear to segments, non-adjusted per CBC 2306.3
Adjusted sh ear value per CBC 2306.3
:11
.j
:2
L2 (ft.)
8.0
140
140
175
280
v,.,._,
Total
Length (ft.)
15
w
77
77
96
153
Perforated
Length (ft.)
12
plf
I bs.
pit
I bs.
-;TpJ;;-. --·
V(bo-}
UPLIFT
Uplift E 280
Add. Uplift E
Uplift W -412
Add. UpliftW
Tot. Uplift E 280
Tot. UpliftW -412
HO# •
Overall
H/L Ratio
0.8
Strap Force
Shear
Use
Use#
v<plrJ
I
I
I
I
I
I
bs.
bs.
bs.
bs.
bs.
bs.
• -No HD required, by inspection
Direction
E-W
Maximum
280
175
CS16
1
L.D.
9/13/2023
Page:
lbs.
plf
strap
Shear Wall
Y•VI\..
V" •VlfLl"-2}
L-13
-' ' .
LOVELACE
ENGINEERING
JOB J2332O -MUNDAY RESIDENCE
SHEETNO. ________ F_-_I_ OF ______ _
CALCULATED BY _______ L_.D_._ DATE _____ _
STRUCTURAL ENGINEERING SERVICES CHECKEDBY __________ DATE _____ _
10509 Vista Sorrento Parkway, Suite 102, Sa n Diego, CA 92121
phone 858.535.9111 • fax 858.535.1 989 • www.lovelaceeng.com SCALE _________________ _
FOUNDATION DESIGN
ALLOHABLE BEARIN6 PRESSURE, q = 1500 PSF (PER DESl6N CRITERIA)
CONTINUOUS PERIMETER 4 BEAi<IN6 HALL FOOTIN6S:
LOCATION: MAX CONTINUOUS FOOTIN6
H 1 = MAX LOAD = 1500 PLF
HIDTH REQ'D= (H1/q x 12) = 1500,<50 x 12 = 12 IN
I USE: 12 11 HIDE X 12 " DEEP HITH _2_ #__±_TOP 4 BOTTOM I
LOCATION, ___________________ _
H 1 = ____________________ = ___ PLF
HIDTH -REQ'D= (H1 /q x 12) = = IN
IUSE: II HIDE X II DEEP HITH TOP 4 BOTTOM I
LOCATION: ___________________ _
H 1 = ____________________ = ___ PLF
HIDTH REQ'D= (Hifq x 12) = = IN
1usE, 11 HIDE X ___ 11 DEEP HITH __ # __ TOP 4 BOTTOM I
ISOLATED SPREAD FOOTIN6S: ( I-STORY CONT. FT6. POINT LOADS J
MA-RK : (F-1)
P= CONT. FT6. CAPACITY (MIDWALL) = 3000 LBS
A,eq'd = P/q X 144= 3000koo X 144
USE: IZJ PER PAD FOOTIN6 SCHEDULE
MA-RK, (F-2)
P= CONT. FT6. CAPACITY (ENDWALL)
A,eq'd = P/q x 144= 2259<'soo x 144
USE: IZJ PER PAD FOOTIN6 SCHEDULE
MA-RK: (F-3)
= 288 SQ IN
= 2250 LBS
= 216 SQ IN
P= 18" x 18" x 12" DEEP PAD FT6. CAPACITY = 3315 LBS
A,eq'd = P/q x 144= 331%00 X 144
USE: IZI PER PAD FOOTIN6 SCHEDULE
= 324 SQ IN
I2"x24"=2881n2
I2"xl8"=2161n2
18"xl8"=324In2
LOVELACE
ENGINEERING
JOB J23320 -MUNDAY RESIDENCE
SHEET NO. F-2 OF -------
CALCULATEDBY _______ L_.D_. -DATE _____ _
STR U CTURAL EN GI NEER I N G SERVICES
10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121
CHECKED BY __________ DATE _____ _
phone 858.535.91 11 • faxBSB.535.1989 • www.lovelaceeng.com SCALE _________________ _
FOUNDATION DESIGN
ALLOHABLE BEARIN6 PRESSURE, q= 1500 PSF (PER DESl6N CRITERIA)
CONTINUOUS PERIMETER 4 BEA'RIN6 V'IALL FOOTIN6S:
LOCATION: MAX CONTINUOUS FOOTING
H1= MAX LOAD = 1815 PLF
HIDTH REQ'D= (H1/q x 12) = IE>•1f'soo x 12 = 15 IN
I USE: 15 11 HIDE X 18 11 DEEP HITH 2 # 4 TOP 4 BOTTOM j
LOCATION, --------------------
H 1 = ___________________ = ___ PLF
HIDTH R EQ'D= (HI /q x 12) = = IN
jUSE, II HIDE X II DEEP V'IITH TOP 4 BOTTOM I
LOCATION, __________________ _
H1 = = PLF
HIDTH REQ 'D= (H1/q x 12) = = IN
IusE: ___ 11 HIDE x 11 DEEP HITH __ # __ TOP 4 BOTTOM I
ISOLATED SPREAD FOOTIN6S: ( 2-STORY CONT. FT6. POINT LOADS)
MARK: (F-4)
P= CONT. F T6. CAPACITY (MIDHALL) = 5625 LBS
A,oq'd = P/q X 144= Sb.21f'5oo X 144 = 540 SQ IN
USE: IZI PER PAD FOOTIN6 SCHEDULE I5"x36"=540in2
MARK, (F-5)
P= CONT. F T6. CAPACITY (ENDHALL) = 3281 LBS
Areq'd = P/q X 144= 3.2e,.!fooo x 144 = 315 SQ IN
USE: IZI PER PAD FOOTIN6 SCHEDULE
MARK, (F-6) I5"x2I "=3 I5 in2
P= 18" x 18 " x 18" DEEP PAD FT6. CAPACITY = 3315 LBS
A,eq'd = P/q X 144= 3311(50 X 144 = 324 SQ IN
USE: IZI PER PAD FOOTIN6 SCHEDULE I8"xl8"=324ln2
LOVELACE
ENGINEERING
STRUCTURAL ENGINEERING SERVICES
STRUCTURAL CALCULATIONS
DATE:
PROJECT:
DESIGNER:
JOB:
AUGUST 15, 2023
MUNDAY RESIDENCE
2087 WESTWOOD DRIVE
CARLSBAD, CA 92008
A DESIGN
ALISA EICHELBERGER
ALISA@ADESIG N-SHOP.COM
CARLSBAD, CA
]23320
o. C 397~
CBR2023-4083
if:CA\.: 2087 WESTWOOD DR
MUNDAY; NEW 236 SQ FT ADDITION/ REMODEL KITCHEN
AND NEW MUD ROOM
858.535.91
10509 Vista S1 1671800700
8/28/2023
CBR2023-4083
LOVELACE
ENGINEERING
STRUCTURAL ENGINEERING SERVICES
10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121
Joa J23320 -MUNDAY RESIDENCE
SHEET NO. _________ T_C_-_I OF-------
CALCULATED BY _______ L_.D_._ DATE _____ _
CHECKEDBY __________ DATE _____ _
phone 858.535.9111 • fax 858.535.1989 • www.lovelaceeng.com SCALE __________________ _
TABLE OF CONTENTS
SUBJECT SHEET
DESIGN CRITERIA ...................................................................................................................................................... DC-I
DESIGN LOADS ........................................................................................................................................................... DL-1
VERTICAL ANALYSIS/DESIGN .............................................................................................................................. V-1/6
LATERAL ANALYSIS/DESIGN ............................................................................................................................... L-1/13
FOUNDATIONS/ RETAINING HALLS ................................................................................................................... F-1/2
STRUCTURAL NOTES/ SCHEDULES/ DETAILS (WHERE APPLICABLE) ............................................ .
TOTAL
LOVELACE
ENGINEERING
Jos J23320 -MUNDAY RESIDENCE
SHEET NO. DC-I OF -------
CALCULATEDBY _______ L._D_._ DATE _____ _
STRUCTURAL ENGINEERING SERVICES CHECKEDBY __________ DATE _____ _
10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121
phone 858.535.9111 • fax 858.535.1989 • www.lovelaceeng.com SCALE _________________ _
DESIGN CRITERIA
GOVERNING CODE: CBC 2022
CONCRETE: ACI 318-1 9
f'e,=2500 psl, NO SPECIAL INSPECTION REQ'D. (U.N.O.)
MASONRY: TMS 402-16 / ACI 530-13
MEDIUM HEIGHT, ASTM CCIO, F'm= 1500 psi, SPECIAL INSP. REQ'D
MORTA'R: ASTM C210, f 'e,=I800 psl, TYPES
eROUT: ASTM C416, f'e,=2000 psi
'REINFORCING STEEL, ASTM A6I5, F~= 40ksi FOR# 4 AND SMALLER
AS TM Ab 15, F~ = bOksi FOR # 5 AND LARGER (U.N.O.)
STRUCTURAL STEEL: AISC 360-16, 15TH EDITION
ASTM A512, F~= 50 ksl (STEEL SHAPES) U.N.O .
ASTM A500, GRADE B, F~= 46ksi (STRUCTURAL TUBE)
ASTM A53, GRADE B, F~= 35ksl (STRUCTURAL PIPE)
ASTM A36, F~= 36 ksi (PLATES)
BOLTING: A301, SINGLE PLATE SHEAR CONN.
WELDING:
Y'IOOD:
GLULAMS:
SOIL:
A325-N, A490-N Hl6H STRENGTH, SIN6LE PLATE SHEAR CONN.
ElOXX SERIES-TYP., ECfO SERIES FOR A6I5 6RADE 60 REBAR
SHOP WELDING TO BE DONE IN AN APPROVED FABRICATOR'S SHOP
FIELD WELDING TO HAVE CONTINUOUS SPECIAL INSPECTION.
NDS-I8
DOUGLAS FIR LARCH
24F-V4 FOR SIMPLE SPAN CONDITIONS
24F-V8 FOR CANTILEVER CONDITION
ALLOWABLE BEARING PRESSURE
ACTIVE SOIL PRESSURE
=1500
=
AT-REST SOIL PRESSURE (RESTRAINED) = __ _
PASSIVE SOIL PRESSURE = __ _
LATERAL EARTHQUAKE PRESSURE = __ _
COEFFICIENT OF FRICTION =
181 EXISTIN6 NATURAL SOIL PER CBC TABLE 18062
SOILS REPORT BY,
PROJECT NUMBER,
DATED,
psF
pd
pd
pd
pd
LOVELACE
ENGINEERING
Jos J23320 -MUNDAY RESIDENCE
SHEET NO. DL-1 OF ------
CALCULATED BY _______ L_.D_._ DATE _____ _
STRUCTURAL ENGINEERING SERVICES CHECKED BY __________ DATE _____ _
10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121
phone858.535.9111 • fax 858.535.1989 • www.lovelaceeng.com SCALE _________________ _
DESIGN LOADS
ROOF
DEAD LOAD:
ROOFING (COMP.SHINGLES) ............................. .
SHEATHIN6 ................................................ .
RAFTER/CEILING JOISTS OR TRUSSES ...................... .
INSULATION ................................................ .
DRYHALL ................................................. .
OTHER (ELEC., MECH., MISC.) ............................... .
TOTAL DEAD L OAD:
LIVE LOAD: (ROOF USE PER IBC TABLE 1601.1)
TOTAL LOAD:
FLOOR
DEAD LOAD:
FLOORING ( CARPET 4 PAD ) ............................ .
DEX-0-TEX ............................................... .
SHEATHING ................................................ .
JOISTS .................................................... .
DRYHALL /STUCCO ....................................... .
OTHER (ELEC., MECH., MISC.) .............................. .
TOT AL DEAD LOAD:
LIVE LOAD: (RESIDENTIAL USE PER IBC TABLE 1601.1)
TOTAL LOAD,
EXTERIOR WALL
STUDS ..................................................... .
DRYHALL ................................................. .
INSULATION ................................................ .
EXTERIOR FINISH (STUCCO) .............................. .
OTHER (MI SC.) ............................................ .
TOTAL LOAD:
INTERIOR WALL
STUDS ..................................................... .
DRYHALL ................................................. .
OTHER (MISC.) ............................................ .
TOTAL LOAD:
4.0 psf
1.5
3.5
1.5
2.5
1.0
14.0 psf
20.0 f2SF
34.0psf
5.0 psf
.0
2.0
3.5
2.5
2.0
15.0 psf
40.0 f2SF
55.0 psf
I.Opsf
2.5
1.5
10.0
1.0
16.0 psf
1.0 psf
5.0
1.0
1.0 psf
+ SOLA'R
4.0
18.0 psf
20.0 f2SF
38.0psf
DECK/OTHER
2.5 psf
2.5
2.0
3.5
10.0
4.5
25.0 psf
60.0 f2SF
85.0psf
LOVELACE
ENGINEERING
STRUCTURAL ENGINEERING SERVICES
10509 Vista Sorrento Parkway, Suite 102, Sa n Diego, CA 92121
V-1
Jos --123320 -MUNDAY RESIDENCE
SHEET NO. V -I OF -------
CALCULATED BY ________ L_.D_._ DATE _____ _
CHECKEDBY __________ DATE _____ _
phone 858.535.9111 • fax 858.535.1989 • www.lovelaceeng.com SCALE __________________ _
VERTICAL ANALYSIS/ DESIGN
LEVEL, -ROOF
MEMBE-R.S: -R.AFTE-R.S 4 HEADE-RS ISEE CODE CHECK CALCULATIONS THAT FOLLOH!
MARK: RR-I SPAN= 14 FT. eRID LINE: ~ FULL SPAN UNIFORM LOAD
WI D= (18 12sf)*(4'/2) -36 D
(plf) L = (20 12sf)*(4'/2) = 40 Lr, L
W2 D= D
(plf) L = Lr L
V'13 D= D
(plf) L = Lr L
Pl D= D Maximum Reae,tfons (lbs)
(lbs) L= Lr L D Lr L
P2 D= D 'RI~ Z/0 I;~~ I (lbs) L=
I USE:
L 'Rt-= 210
2 X 10 @ 24" 0.C. 0-R. I i<m
MA'RK: RH-I SPAN= 6 FT. eRID LINE: I 12J FULL SPAN UNIFORM LOAD
WI D= (18 r;2sf)*((l4'/2)+2') -162 D
(plf) L = (20 12sf)*((l4'!2)+2') -180 Lr, L
W2 D= D
(plf) L= Lr L
H3 D= D
(plf) L = Lr L
Pl D= D Max imum Reactions (lbs)
(lbsJ L= = Lr L D Lr L
P2 D= : :~ ;~~ I ;:1 (lbsJ L=
I USE: 4x6 OR I-Rm
MARK: RH-2 SPAN= 3 FT. GRID LINE: 2 ~ FULL SPAN UNIFORM LOAD
WI D= (18 12sf)*((l4'/2)+2') -162 D
(plf) L = (20 12sf)*((l4'/2)+2') = 180 Lr, L
W2 D= (18 12sf )*(24'/2) = 216 D
(plfJ L= (20 12sf)*(24'/2) = 240 Lr, L
H3 D= D
(plf) L = Lr L
Pl D= D Maximum 'Reae,tlons (lbs)
(lbs) L= Lr L D Lr L
P2 D = = D ~~ 510 =~~ (lbsJ L= L 510
I USE: 4x6 OR I
Project Title:
--~ Lovelace Engineering, Inc.
Engineer:
MUNDAY RESIDENCE
L.D. V-2
... 10509 Vista Sorrento Pkwy Suite 102
San Diego, CA 92121
Wood Beam
UC#: KW-06013959, Build:20.23.05.25
DESCRIPTION: RR-1
CODE REFERENCES
Calculations per NOS 2018, IBC 2021, ASCE 7-16
Load Combination Set : IBC 2021
Material Properties
Analysis Method : Allowable Stress Design
Load Combination : IBC 2021
Wood Species
Wood Grade
Douglas Fir-Larch
No.2
Project ID:
Project Descr:
Lovelace Engineering, Inc.
Fb +
Fb -
Fe -Prll
Fe -Perp
Fv
Ft
Beam Bracing Beam is Fully Braced against lateral-torsional buckling
D 0.036 Lr 0.04
£ 2x10
Span; 14.0 ft
J23320
900 psi
900 psi
1350 psi
625 psi
180 psi
575 psi
Project File: J23320 -VERTICAL.ec6
(c) ENERCALC INC 1983-2023
E : Modulus of Elasticity
Eb end-xx 1600 ksi
Eminbend -xx 580ksi
Density 31.21 pcf
Repetitive Member Stress Increase
1
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loading
Uniform Load : D = 0.0180, Lr = 0.020 ksf, Tributary Width= 2.0 ft, (ROOF)
D_ESIGN.Sl.!MMl:!BY_ . Design OK
Maximum Bending Stress Ratio = 0.763: 1 Maximum Shear Stress Ratio = 0.237 : 1
Section used for this span 2x10 Section used for this span 2x10
fb: Actual = 1,085.90 psi fv: Actual = 53.24 psi
F'b = 1,423.13psi F'v = 225.00 psi
Load Combination +D+Lr Load Combination +D+Lr
Location of maximum on span 7.000ft Location of maximum on span = 13.234 ft
Span# where maximum occurs = Span# 1 Span# where maximum occurs = Span# 1
Maximum Deflection
Max Downward Transient Deflection 0.220 in Ratio= 764 >=360 Span: 1 : Lr Only
Max Upward Transient Deflection O in Ratio= 0 <360 n/a
Max Downward Total Deflection 0.434 in Ratio= 387 >=240 Span: 1 : +D+Lr
Max Upward Total Deflection O in Ratio= 0 <240 n/a
•••••• ••➔••··-···-·
Maximum Forces & Stresses for Load Combinations
Load Combination
Segment Length V CD CM Ct CLx CE Cfu C. Cr M fb F'b V fv F'v I
DOnly 0.0 0.00 0.0 0.0
Length = 14.0 ft 0.523 0.162 0.90 1.00 1.00 1.00 1.100 1.00 1.00 1.15 0.96 536. 1 1,024.7 0.24 26.3 162.0
+D+Lr 1.00 1.00 1.00 1.100 1.00 1.00 1.15 0.0 0.00 0.0 0.0
Length = 14.0 ft 0.763 0.237 1.25 1.00 1.00 1.00 1.100 1.00 1.00 1.15 1.94 1,085.9 1,423.1 0.49 53.2 225.0
+D+0.750Lr 1.00 1.00 1.00 1.100 1.00 1.00 1.15 0.0 0.00 0.0 0.0
Length= 14.0 ft 1 0.666 0.207 1.25 1.00 1.00 1.00 1.100 1.00 1.00 1.15 1.69 948.5 1,423.1 0.43 46.5 225.0
+0.60D 1.00 1.00 1.00 1.100 1.00 1.00 1.15 0.0 0.00 0.0 0.0
Length= 14.0 ft 0.177 0.055 1.60 1.00 1.00 1.00 1.100 1.00 1.00 1.15 0.57 321.7 1,821.6 0.15 15.8 288.0
Wood Beam
UC#: KW-06013959, Build:20.23.05.25
DESCRIPTION: RR-1
Vertical Reactions
Load Combination
Max Upward from all Load Conditions
Max Upward from Load Combinations
Max Upward from Load Cases
DOnly
+D+Lr
+D+0.750Lr
+0.60D
Lr Only
Project Title:
Engineer:
Project ID:
Project Descr:
Lovelace Engineering, Inc.
MUNDAY RESIDENCE
L.D.
J23320
V-3
Project File: J23320 -VERTICAL.ec6
(c) ENERCALC INC 1983-2023
Support notation : Far left is #1 Values in KIPS
Support 1 Support 2
0.553 0.553
0.553 0.553
0.280 0.280
0.273 0.273
0.553 0.553
0.483 0.483
0.164 0.164
0.280 0.280
-· ~ Lovelace Engineering, Inc. 4-10509 Vista Sorrento Pkwy Suite 102
San Diego, CA 92121
I Multiple Simple Beam
UC#: KW-06013959, Build:20.23.05.25
Description : ROOF HEADERS
Wood Beam Design: RH-1
BEAM Size : 4x6, Sawn, Fully Unbraced
Project Title:
Engineer:
Project ID:
Project Descr:
Lovelace Engineering, Inc.
MUNDAY RESIDENCE
L.D.
J23320
V-4
Project File: J23320 -VERTICAL.ec6
(c) ENERCALC INC 1983-2023
Calculations per NOS 2018, IBC 2021, ASCE 7-16
Using Allowable Stress Design with IBC 2021 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir-Larch Wood Grade : No.2
Fb-Tension
Fb -Compr
900 psi Fe -Prtl 1350 psi Fv 180 psi Ebend-xx 1600 ksi
580 ksi
Density 31 .21 pcf
900 psi Fe -Perp 625 psi Ft 575 psi Eminbend -xx
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.1620, Lr = 0.180 k/ft, Trib= 1.0 ft
Design Summary
Max fb/Fb Ratio =
fb : Actual :
0.730; 1
1,059.36 psi at
1,452.09 psi
+D+Lr
3.000 ft in Span# 1
Fb : Allowable :
Load Comb :
Max fv/FvRatio =
fv : Actual :
Fv : Allowable :
Load Comb :
Max Reactions (k)
Left Support Right Support
0.307: 1
69.05 psi at
225.00 psi
+D+Lr
.Q l.r L.
0.50 0.54 0.50 0.54
Wood Beam Design : RH-2
5.560 ft in Span# 1
'l:l.. E
BEAM Size : 4x6, Sawn, Fully Unbraced
----------· _:¥::~:: 7:;;:.-r ~-:.,~-: .. :: :::.-~~:---_A4~",►~•1 =d:;~~~-: -~=:•-:-;.-'y_~~.;;~i-:~ :.;:.:
ti
-"'! ~,-• ' ., , • .J ~ ~.:--~ •
Max Deflections
Transient Downward
Ratio
4x6
6.0 ft
0.068in
1059
LC: Lr Only
Transient Upward 0.000 in
Ratio 9999
LC:
Total Downward
Ratio
Total Upward
Ratio
0.131 in
550
LC: +D+Lr
0.000 in
9999
LC:
Calculations per NOS 2018, IBC 2021, ASCE 7-16
Using Allowable Stress Design with IBC 2021 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir-Larch Wood Grade : No.2
Fb -Tension
Fb-Compr
900 psi Fe -Prll 1350 psi Fv 180 psi Ebend-xx 1600 ksi
580 ksi
Density 31.21 pcf
900 psi Fe -Perp 625 psi Ft 575 psi Eminbend -xx
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.1620, Lr= 0.180 k/ft, Trib= 1.0 ft
Unif Load: D = 0.2160, Lr = 0.240 k/ft, Trib= 1.0 ft
Design Summary
Max fb/Fb Ratio =
fb : Actual :
Fb : Allowable :
0.421 • 1
613.70 psf at
1,457.04 psi
+D+Lr
1.500 ft in Span # 1
Load Comb :
Max fv/FvRatio =
fv : Actual :
Fv : Allowable :
Load Comb :
Max Reactions (k)
Left Support
Right Support
0.292: 1
65.63 psi at
225.00 psi
+D+Lr
Q l.r L.
0.57 0.63
0.57 0.63
2.550 ft in Span# 1
'l:l.. E ti
---== ·:;. _'; .:. .. ~---. --':. -::-:.
·_---,<}·;..-~: ·-~""'="~--~·-·---:-··--:·. ~-~-7-... _ .j;
,. . . -.
3.0 ft
Max eflections
Transient Downward 0.010in
3632 Ratio
Transient Upward
Ratio
LC: Lr Only
0.000in
9999
LC:
Total Downward
Ratio
Total Upward
Ratio
0.019 in
1901
LC: +D+Lr
0.000 in
9999
LC:
V-5 f,,. : LOVELACE
ENGINEERING
Jos J23320 -MUNDAY RESIDENCE
SHEET NO. __________ OF ______ _
CALCULATEDBY ________ L_.D_._ DATE _____ _
STRUCTURAL ENGINEERING SERVICES CHECKEDBY __________ DATE _____ _
70509 Vista Sorrent o Parkway, Suite 702, San Diego, CA 92721
phone 858.535.9111 • fax 858.535.1989 • www.lovelaceeng.com SCALE __________________ _
LEVEL : FLOOR
MEMBERS: HEADERS a BEAMS ISEE GODE GHEGK CALCULATIONS THAT FOLLOHI
MARK: FH-1 SPAN= 8 FT. eRID LINE: ~ FULL SPAN UNIFORM LOAD
HI D= (18 12sF )*(34 '/2) = 306 D
(plf) L = (20 12sf)*(34'/2) = 340 Lr, L
H2D= (15 12sF)*(2'/2) 15 = D
t t (plf) L = (40 12sF)*(2'/2) = Lr, 40 L
H3D= (16 12sf)*(C!') = 144 D
(plf) L = = Lr I. I L " " Pl D= = D Maximum Reac.tlons (lbs)
(lbs) L = = Lr L D Lr L
P2 D= = D i<t= 18C!O 1360 160
(lbs) L = Ir L 'R,-= 18C!O 1360 160
I USE: 4 X 12 OR I -Rm=
MAi<K: FB-1 SPAN= 14 FT. eRID LINE: B ~ FULL SPAN UNIFORM LOAD
HI D= (1 8 12sF)*(4'/2) = 36 D
(plf) L = (20 12sF)*(4'/2) = 40 Lr, L
H2D= (15 f2SF)*(14'/2) 105 = D
t t (plf) L = (40 f2SF)*(l4'/2) = Lr, 280 L
H3D= (16 12sf)*(l2') = IC!2 D
(plf) L = = Lr L I I.
" ~
Pl D= = D Maximum Reac.tlons (lbs)
(lbs) L= = Lr L D Lr L
P2 D= = D R1= 2460 280 IC!60
(lbs) L= 1,,. L i<r= 2460 280 IC!60
I USE: ~II~ I~" E5L OR I --Rm=
MARK, SPAN= FT. cSRID LINE: 0 FULL SPAN UNIFORM LOAD
HI D= = D
(plf) L = = Lr L
H2D= = D
t t (plf) L = = Lr L
H3D= = D
(plf) L = = Lr L I. I.
" " Pl D = = D Maximum i<eac.tlons (lbs)
(lbs) L= = Lr L D Lr L
P2 D = = D ~ (lbs) L = 1,,. L
I USE: OR I
,;;J1t ~ Lovelace Engineering, Inc. 4-10509 Vista Sorrento Pkwy Suite 102
San Diego, CA 92121
I Multiple Simple Beam
UC#: KW-06013959, Build:20.23.05.25
Description : FLOOR HEADERS & BEAMS
Wood Beam Design : FH-1
BEAM Size : 4x12, Sawn, Fully Unbraced
Project Title:
Engineer:
Project ID:
Project Descr:
Lovelace Engineering, Inc.
MUNDAY RESIDENCE
L.D.
J23320
V-6
Project File: J23320 -VERTICAL.ec6
(c) ENERCALC INC 1983-2023
Calculations per NDS 2018, IBC 2021, ASCE 7-16
Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir-Larch Wood Grade : No.1
Fb -Tension
Fb -Compr
1,000.0 psi Fe -Prll 1,500.0 psi Fv 180.0 psi Ebend-xx 1,700.0 ksi
620.0 ksi
Density 31 .210 pcf
1,000.0 psi Fe -Perp 625.0 psi Ft 675.0 psi Eminbend -xx
Applied Loads
Beam self weight calculated and added to loads
Unit Load: D = 0.3060, Lr= 0.340 k/ft, Trib= 1.0 ft
Unif Load: D = 0.0150, L = 0.040 k/ft, Trib= 1.0 ft
Unit Load: D = 0.1440 k/ft, Trib= 1.0 ft
Design Summary
Max fb/Fb Ratio =
fb : Actual :
0.787 • 1
1,057.85 psf at
1,344.01 psi
+D+Lr
4.000 ft in Span # 1
Fb : Allowable :
Load Comb :
Max fv/FvRatio =
fv: Actual :
Fv : Allowable :
Load Comb :
Max Reactions (k)
Left Support Right Support
0.422: 1
95.04 psi at
225.00 psi
+D+Lr
Q lJ:
1.89 1.36 1.89 1.36
L
0.16 0.16
Wood Beam Design: FB-1
0.000 ft in Span# 1
s. E jj
BEAM Size : 5.25x11.25, Parallam PSL, Fully Unbraced
,S' t."' ~ i~"" • • :, e ~ ":. -------------------------~-::~::~-----, .. -~, ~ ~~; .... ~,:-:,;--~~=-7-~--;·~:--:.~-~~-::-:;=-.,.~,;--:
.-~ .. , .. -.,·.,-: '".;,-/-:L :-::-~.--.:·:-":':,-,>~:_--~~ .,~,~~, .• :~
8.0ft
ax Deflections
Transient Downward 0.045 in
2151 Ratio
Transient Upward
Ratio
LC: Lr Only
0.000in
9999
LC:
Total Downward
Ratio
Total Upward
Ratio
0.107 in
899
LC: +D+Lr
0.000 in
9999
LC:
Calculations per NDS 2018, IBC 2021, ASCE 7-16
Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending
Wood Species : iLevel Truss Joist Wood Grade : Parallam PSL 2.0E
Fb -Tension
Fb -Compr
2,900.0 psi Fe -Prll 2,900.0 psi Fv 290.0 psi Ebend-xx 2,000.0 ksi Density 45.070 pct
2,900.0 psi Fe -Perp 750.0 psi Ft 2,025.0 psi Eminbend -xx 1,016.54 ksi
Applied Loads
Beam self weight calculated and added to loads
Unit Load: D = 0.0360, Lr= 0.040 k/ft, Trib= 1.0 ft
Unit Load: D = 0.1050, L = 0.280 k/ft, Trib= 1.0 ft
Unit Load: D = 0.1920 k/ft, Trib= 1.0 ft
Design Summary
0.586: 1 Max fb/Fb Ratio =
fb : Actual : Fb : Allowable :
1,676.48 psi at 7.000 ft in Span# 1
2,861 .01 psi
Load Comb :
Max fv/FvRatio =
fv : Actual :
Fv : Allowable :
Load Comb :
Max Reactions (k)
Left Sup port
Right Support
+D+L
0.336: 1
97.30 psi at 13.067 ft in Span# 1
290.00 psi
+D+L
Q lJ:
2.46 0.28
2.46 0.28
L
1.96
1.96
s. Y:i.. E jj
Max Deflections
Transient Downward 0.195 in
860 Ratio
Transient Upward
Ratio
LC: L Only
0.000in
9999
LC:
Total Downward
Ratio
Total Upward
Ratio
0.440 in
381
LC: +D+L
0.000 in
9999
LC:
~ LOVELACE MUNDAY RESIDENCE
ENGINEERING JOANNA & TREY MUNDAY
CTRUCTUDAL 5NOI MSfiAINO IEAV cc■ J23320
SEISMIC WEIGHT
Level 2 ROOF Typical Plate Ht. (ft.)
Element Type Dead Load (psf) Area (sf)
Diaphragm ROOF 18 1150
Diaphragm
Diaphragm
Dead Load (psf) Length (ft.)
Wall EXTERIOR 16 125
Wall INTERIOR 7 95
Wall
Dead Load (lbs.)
Misc./ Concentrated
Total Weight (lbs.) 44685 Seismic Weight (lbs.)
Level 1 FLOOR Typical Plate Ht. (ft.)
Element Type Dead Load (psf) Area (sf)
Diaphragm FLOOR 20 960
Diaphragm ROOF 18 1200
Diaphragm
Dead Load (psf) Length (ft.)
Wall EXTERIOR 16 225
Wall INTERIOR 7 130
Wall
Dead Load (lbs.)
Misc./ Concentrated
Total 81390 Seismic Weight
9
Weight
20700
0
0
Weight
18000
5985
0
Weight
0
32692.S
9
Weight
19200
21600
0
Weight
32400
8190
0
Weight
0
73087.5
L-1
l.D.
8/15/2023
Page:
ASCE.
AMffilCAN SOCIETY OF Clli'IL ENGINEffiS
Address:
2087 Westwood Dr
Carlsbad, California
92008
Wind
Results:
Wind Speed
10-year MRI
25-year MRI
50-year MRI
100-year MRI
Data Source:
Date Accessed:
L-2
ASCE 7 Hazards Report
Standard: ASCE/SEI 7-16
Risk Category: II
Soil Class: D -Default (see
Section 11.4.3)
96 Vmph
66 Vmph
72 Vmph
77 Vmph
82 Vmph
Latitude: 33 .16823
Longitude: -117.329546
Elevation: 217.34766516706733 ft
(NAVO 88)
ASCE/SEI 7-16, Fig . 26.5-1B and Figs. CC.2-1-CC.2-4, and Section 26.5.2
Thu Jun 15 2023
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability =
0.00143, MRI= 700 years).
Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2.
https :/ /a see 7haza rdtool .online/ Page 1 of 3 Thu Jun 15 2023
ASCE.
AME!IICAN SOC!ElY OF CML ENGINEERS
Seismic
Site Soil Class:
Results:
D -Default (see Section 11.4.3)
1.02 So1
0.372 TL :
1.2 PGA:
N/A PGAM:
1.224 F PGA
N/A
8
0.447
0.536
1.2
N/A le SM1 1
Sos 0.816 Cv : 1.304
Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11 .4.8.
Data Accessed: Thu Jun 15 2023
Date Source: USGS Seismic Design Maps
https :/ /a see 7hazardtool.online/ Page 2 of 3
L-3
Thu Jun 15 2023
L-4
ASCE.
AMERICAN SOCIElY Of CML ENGINEERS
The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided "as is" and without warranties of
any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers;
or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from
reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability,
currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement,
affiliation, relationship, or sponsorship of such third-party content by or from ASCE.
ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE 7 Hazard Tool.
https://asce 7hazardtool .online/ Page 3 of 3 Thu Jun 15 2023
-~ LOVELACE ~ ENGINEERING
1-fWUt:IUNAL l:NUlll .t:t:.NINO 1,~WVl<.:~11
MUNDAY RESIDENCE
JOANNA & TREY MUNDAY
J23320
SEISMIC BASE SHEAR
Level
2
1
Period Calculation
Overall Ht. System
23 All Other Systems
Ts=
Ta = Cth; Ta =
TL =
Base Shear
System R
Wood Shear Walls 6.5
Site Class: CO
SOS=~
5D1 = 0.478
s1 = 1 o.372
Fx = c 11X v
ht. (ft.)
13
10
23 ft.
wx(lbs.)
32692.5
73087.5
Vertical Distribution
hx
23
10
Ct X
0.02 0.75
0.586 s
0.210 s
8 s
Omega Cd
2.5
Cs =
W=
V=
k
1
1
1
4.5 1.0
0.126
105.78 k
13.28 k
Total Base Shear
wx*hx"k Cvx
751927.5 0.507098889
730875 0.492901111
1482802.5
L.D.
8/15/2023
Page:
per ASCE 7, Fig. 22-14
per ASCE 712.8.1.1
Fx
k
6.7 k
6.5 k
Ta= Crhnx
Ta= 0.2 10
fV = 1.928 FROM TABLES & LINEAR
SM1 = S1 * fV
T SD1/ s = SDs
SM1 = 0.717
Ts= 0.586 SD1 = C2h)SM1
l.STs = 0.878941 SD1 = 0.478
:. Per exception 2 of ASCE 7 -16 section 11.4.8
Ta < l.STs so C5 from equation 12.8 -2 can
be used and does not need to be factored.
INTERPOLATION
L-5
t~ LOVELACE PROJECT : MUNDAY RESIDENCE
v....; ENGINEERING CLIENT : JOANNA & TREY MUNDAY
"'"'""' ,,., •• .,."' ""'"" JOB NO.: J23320 DATE : 06/16/23
Wind Anal sis for Low-rise Buildin , Based on 2018 IBC/ASCE 7-16
INPUT DATA
Exposure category (B, c or D, ASCE 7-16 26.7.3)
Importance factor (ASCE 7-16 Table 1.5-2)
Basic wind speed (ASCE 7-16 26.5.1 or 2018 IBC)
Topographic factor (ASCE 7-1 6 26.8 & Table 26.8-1)
Building height to eave
Building height to ridge
Building length
Building width, including overhangs
Overhang sloped width
lw =
V =
Kz1 =
he=
hr =
L
B =
C
1.00
96
for all Category
mph, (154.50 kph)
Flat
ft, (6.10 m)
ft, (7.92 m)
ft, (10.36 m)
ft, (9.14 m)
ft, (0.46 m)
PAGE :
DESIGN BY : L.D.
REVIEW BY :
Effective area of components (or Solar Panel area)
Oh =
A =
20
26
34
30
1.5
12 tf, <== Overhang? (Yes or No) No
( 1.12 m2)
DESIGN SUMMARY
Max horizontal force normal to building length, L, face
Max horizontal force normal to building length, B, face
Max total horizontal torsional load
12.46 kips, (55 kN), SD level (LRFD level), Typ.
11.04 kips, (49 kN)
Max total u ward force
ANALYSIS
Velocity pressure
qh = 0.00256 Kz Kzt Kd K. V2
55.9517 ft-kips, (76 kN-m)
17.55 ki s 78 kN
18.53 psf
where: qh = velocity pressure at mean roof height, h. (Eq. 26.10-1 page 268)
K, = velocity pressure exposure coefficient evaluated at height, h, (Tab. 26.10-1. pg 268)
K,t = wind directionality factor. (Tab. 26.6-1 , for building, page 266)
h = mean roof height
0.92
0.85
23.00 ft
L-6
K. = ground elevation factor. (1.0 per Sec. 26.9, page 268) < 60 ft, [Satisfactory]
~ ___ <_M_i_n~L~, B), [Satisfactory]
(ASCE 7-16 26.2.1)
(ASCE 7-16 26.2.2)
Design pressures for MWFRS
p = qh [(G Cpr )-(G cpl )]
where: p = pressure in appropriate zone. (Eq. 28.3-1 , page 311 ). Pmin = 16 psf (ASCE 7-16 28.3.4)
G Cp, = product of gust effect factor and ex1ernal pressure coefficient, see table below. (Fig. 28.3-1, page 312 & 313)
G Cp 1 = product of gust effect factor and internal pressure coefficient.(Tab. 26.13-1, Enclosed Building, page 271)
0.18 or -0.18
a= width of edge strips, Fig 28.3-1, page 312, MAX[ MIN(0.1 B, 0.1 L, 0.4h), MIN(0.04B, 0.04L), 3] = 3.00 ft
Net Pressures (psf), Basic Load Cases Net Pressures (psf), Torsional Load Cases
Roof anole 0 = 21.80 Roof angle 9 = 0.00 Roof anole 9 = 21.80
Surface Net Pressure with Net Pressure with G Cpt (+GCp ;) (-GCp ;) G Cpr (+GCp 1) (-GCP i)
Surface Net Pressure with G Cpr (+GCp 1) (-GCp 1)
1 0.54 6.59 13.26 -0.45 -11 .67 -5.00 1T 0.54 1.65 3.31
2 -0.53 -13.12 -6.45 -0.69 -16.12 -9.45 2T -0.53 -3.28 -1.61
3 -0.47 -12.06 -5.39 -0.37 -10.19 -3.52 3T -0.47 -3.02 -1.35
4 -0.42 -11 .10 -4.43 -0.45 -11 .67 -5.00 4T -0.42 -2.78 -1 .11
5 0.40 4.08 10.75 Roof angle e = 0.00
6 -0.29 -8.71 -2.04
1E 0.78 11 .12 17.79 -0.48 -12.23 -5.56
Surface Net Pressure with G Cp r (+GCp 1) (-GCP i)
2E -0.83 -18.69 -12.02 -1.07 -23.16 -16.49 ST 0.40 1.02 2.69
3E -0.66 -15.59 -8.92 -0.53 -13.16 -6.49 6T -0.29 -2.18 -0.51
4E -0.61 -14.66 -7.99 -0.48 -12.23 -5.56
SE 0.61 7.97 14.64
6E -0.43 -11.30 -4.63
Load Case A (Transverse) Load Case B (Longitudinal) Load Case A (Transverse) Load Case B (Long itudinal)
---------------~~~"Q.Llo.Qd .. CaJ.es Basic Load Ca_s_~
L-7
Basic Load Case A (Transverse Direction) Basic Load Case B (Lonciitudinal Direction)
Area Pressure (kl with Area Pressure (kl with Surface (fl') (+GCpi) (-GCpi) Surface (ft') (+GCp 1) (-GCp1)
1 560 3.69 7.42 Povemang = -12.97 psf 2 452 -7.29 -4.27
2 452 -5.93 -2.92 (ASCE 7-16 28.3.3) 3 452 -4.61 -1.59
3 452 -5.46 -2.44 5 566 2.31 6.09
4 560 -6.22 -2.48 6 566 -4.93 -1.15
1E 120 1.33 2.14 2E 97 -2.25 -1.60
2E 97 -1.81 -1.17 3E 97 -1 .28 -0.63
3E 97 -1 .51 -0.86 SE 124 0.98 1.81
4E 120 -1 .76 -0.96 6E 124 -1.40 -0.57
L Horiz. 12.71 12.71 L Horiz. 9.62 9.62
Vert. -13.66 -6.86 Vert. -11.43 -4.30
Min. wind Horiz. 12.51 12.51 Min. wind Horiz. 11 .04 11.04
28.4.4 Vert. -16.32 -16.32 28.4.4 Vert. -16.32 -16.32
Torsional Load Case A (Transverse Direction) Torsional Load Case B (Longitudinal Direction)
Area Pressure (kl with Torsion (ft-kl Area Pressure (kl with Torsion (ft-kl Surface (fl') (+GC0i) (-GCp 1) (+GCpi) (-GCPi) Surface (ft') (+GCpi) (-GCpi) (+GCpi) (-GCp1)
1 220 1.45 2.92 10 20 2 452 -7.29 -4.27 -4 -2
2 178 -2.33 -1.15 -6 -3 3 452 -4.61 -1 .59 3 1
3 178 -2.14 -0.96 6 2 5 221 0.90 2.38 5 14
4 220 -2.44 -0.98 17 7 6 221 -1.93 -0.45 11 3
1E 120 1.33 2.14 19 30 2E 97 -2.25 -1.60 13 9
2E 97 -1.81 -1.17 -9 -6 3E 97 -1.28 -0.63 -7 -4
3E 97 -1.51 -0.86 8 4 SE 124 0.98 1.81 13 24
4E 120 -1.76 -0.96 25 13 6E 124 -1.40 -0.57 19 8
1T 340 0.56 1.13 -5 -10 ST 345 0.35 0.93 -3 -7
2T 275 -0,90 -0.44 3 1 6T 345 -0.75 -0.18 -5 -1
3T 275 -0.83 -0.37 -3 -1 Total Horiz. Torsional Load, M,, 44.7 44.7
4T 340 -0.94 -0.38 -8 -3
Total Horiz. Torsional Load, M,, 56 56
Design pressures for components and cladding II'r----7'7. Je1 2n IJr ~~'!..iJ~ -----.---,-.r -,-
p = qh[ (G c0) -(G c01n I r--7 I I I I I 5 I 5 I I ._ I I I I I I
where: p = pressure on component. (Eq. 30.3-1, pg 334) a lo,,~" I 5 5 I to"~ 4 2 I 1 I . I I 2,I -12, 2,I -l2e a I I ,g I I I • I I ~ I
Pmin = 16.00 psf (ASCE 7-16 30.2.2) I I I I I.§ I I~ I
G C0 = external pressure coefficient. a I L --..c.+-l I I I I
1.,'I... ____ ...J;,...i: .6h -~-1-Jrh.-·fa, ~ see table below. (ASCE 7-16 30.3.2) Walls 0.2h .6h Je1 2n 1Jr
8= 21 .80 0 Roof 9,7' Roof 9>P
Effective Zone 1 Zone 1' Zone 2 Zone 2• Zone 2n Zone 2r
Area (ft2) GC• -GCp GC• -GC• GCp -GCp GCp -GCp GC• -GC, GCp -GCp
Comp. 12 0.52 -1.50 ----0.52 -1.50 0.52 -2.43 0.52 -2.43
Effective Zone 3 Zone le Zone Jr Zone4 Zone 5
Area(ft2) GCp -GC• GCp -GCp GC• -GCp GCp -GCp GCp -GCp
12 --0.52 -2.43 0.52 -2.82 0.99 -1.09 0.99 -1.37
Zone 1 Zone 1' Zone 2 Zone 2e Zone 2n Zone 2r
Comp. & Cladding Positive NegatJv. Positive Neaatlve Positive Negative Po1ltlve Negative Poaltlve Negative Po,Jt1'11e Negative
Pressure 16.00 -31.13 16.00 -31 .13 16.00 -48.30 16.00 -48.30
( psf) Zone l Zone le Zone 3r Zone 4 Zones
Positive Negative Positive NegatJve Positive Negative Positive Negative Posltlv. Negative (The Max Pressure
16.00 -48.30 16.00 -55.54 21.61 -23.46 21 .61 -28.76 55.54 psf)
L-8
~ MUNDAY RESIDENCE L.D. LOVELACE JOANNA & TREY MUNDAY 8/15/2023 ENGINEERING
J.T.I..CTUlltAL ENOIME&AlNO SIIWfCfU J23320 Page:
LATERA L STORY FORCES
Seismic
Level Fx (lbs.) Diaphragm Area (sf) ASD Story Load (psf)
0 0.7
2 6734 1150 0.7 4.1
1 6545 2160 0.7 2.1
Wind
Direction N-S 8-D
Force= 11.04 k Pressure = 15.3 psf
Level Ht. length area Trib. Ht. ASD diaph. Load
Ridge/Parapet 6 30 180 3 0.6 plf
2 9 30 270 10.5 0.6 97 plf
1 9 30 270 9 0.6 83 plf
720 sf
Direction E-W 1 -4
Force= 12.46 Pressure= 15.3 psf
Level Ht. length area Trib. Ht. ASD diaph. Load
Ridge/Parapet 6 34 204 3 0.6 plf
2 9 34 306 10.5 0.6 96 plf
1 9 34 306 9 0.6 82 pit
816 :sf
I~ LOVELACE ~ ENGINEERING
STAUCT UAAl. t NGINe EAtNO se PVICE$
MUNDAY RESIDENCE Level Name
JOANNA & TREV MUNDAY Level n
J23320 Lateral Line
ROOF
2
1
Direction
E-W
L.D.
8/15/2023
Page:
WOOD SHEARWALL ANALYSIS & DESIGN 11
Area
l
2
3
4
SEISMIC LOAD
sos = 0.816
p = 1.0
Story Load 4.1
SF Factor
1150 1.0
Total/2 = Seismic Load
psf
Load (lbs)
"'11
Load Type L Worst Case
Load (plf) 96
Length L (ft.) 34
Load L (lbs.) 3271
2357 lbs. Total/2 = Wind Load
ADDITIONAL SEISMIC LOAD ADDITIONAL WIND LOAD
Line
Segment
H
H/L Ratio
Load Ratio
Load E
Adj. Load E
Load W
Adj. Load W
Unit Shear E
Unit Shear W
OTM E
OTMW
Wall Weight
Wall UDL
Unif. DL
Concen. DL
COL loc.
DLMoment
DL Mom. E
DLMom. W
Net OT E
NetOTW
Uplift E
Add. Uplift E
Uplift W
Add. Uplift W
Tot. Uplift E
Tot. UpllftW
HD#
Load (lbs.) I Offset Factor
Total Add. Load
Total Seismic Load =
1
Max Shear 0
Adjust. Load
0
2357 lbs.
PLF
SHEAR
I USE#
OVERTURNING
UPLIFT
• -No HD required, by inspection
• • -See Perforated / Force-Transfer Shearwall calculation
Line Load (lbs.)
Total Wind Load =
1 Shear Wall
WINO LOAD
Load Type R
Load (plf)
Length R (ft.)
Load R (lbs.)
1635 lbs.
Offset Factor Adjust. Load
Total Add. Load 0
1635 lbs.
Worst Case
96
0
Total Shear
Length (ft.)
0
lbs.
lbs.
lbs.
lbs.
p/f
pit
Capacity = 260 plf
#-ft.
#-ft.
psf
plf
plf
lbs.
ft.
#-ft.
#-ft.
#-ft.
#-ft.
#-ft.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
L-9
By Ratio
cac 2306 3
I~ LOVELACE ~ ENGINEERING
$TAUCTUlilAl. ~NOINE!:AINO 5f'.IIVICE$
MUNDAY RESIDENCE Level Name
JOANNA & TREY MUNDAY Level#
J23320 Lateral Line
FLOOR
1
A
Direction
N-S
L.D.
8/15/2023
Page:
WOOD SHEARWALL ANALYSIS & DESIGN 11
Area
1
2
3
4
SEISMIC LOAD
sos = 0.816
p = 1.0
Story Load 2.1
SF Factor
320 1.0
Total/2 = Seismic Load
psf
Load (lbs)
"ii
Load Type L Worst Case
Load (plf) 83
Length L (ft.)
Load L (lbs.) 0
339 lbs. Total/2 = Wind Load
ADDITIONAL SEISMIC LOAD ADDITIONAL WIND LOAD
Line
Segment
L
H
H/L Ratio
Load Ratio
Load E
Adj. Load E
Load W
Adj. Load W
Unit Shear E
Unit Shear W
OTM E
OTMW
Wall Weight
Wall UDL
Unif. DL
Concen. DL
CDL loc.
DL Moment
DLMom. E
OLMom.W
Net OT E
NetOTW
Uplift E
Add. Uplift E
Uplift W
Add. Uplift W
Tot. Uplift E
Tot. Uplift W
HD#
Load (lbs.) Offset Factor
Total Add. Load
Total Seismic Load =
1
8
10
1.3
1.00
339
704
503
42
63
Max Shear
3394
7038
16
160
30
6080
2953
3648
441
3390
55
424
55
424
63
I
Adjust. Load
0
339 lbs.
PLF
SHEAR
I USE#
OVERTURNING
UPLIFT
• -No HD required, by inspection
•• -See Perforated/ Force-Transfer Shearwall calculation
Line Load (lbs.)
Total Wind Load=
1 Shear Wall
WIND LOAD
Load Type R
Load (plf)
Length R (ft.)
Load R (lbs.I
704 lbs.
Offset Factor Adjust. Load
Total Add. Load 0
704 lbs.
Worst Case
83
17
1408
Total Shear
Length (ft.)
8
lbs.
lbs.
lbs.
lbs.
plf
plf
Capacity= 260 plf
#-ft.
II-ft.
psf
plf
plf
lbs.
ft.
II-ft.
#-ft.
II-ft.
II-ft.
II-ft.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
L-1 0
By Ratio
C8C2306.3
II~ LOVELACE
~ ·~ ENGINEERING
MUNDAY RESIDENCE Level Name
JOANNA & TREY MUNDAY Level#
ltTRUCTUAAl. !N<JINEf:RIJrrtQ $ERVlCC:S J23320 Lateral Line
FLOOR
1
1
Direction
E-W
L.D.
8/15/2023
Page:
WOOD SHEARWALL ANALYSIS & DESIGN
Area
1
2
3
4
SEISMIC LOAD
sos= 0.816
p = 1.0
Story Load 2.1
SF Factor
320 1.0
660 1.0
Total/2 = Seismic Load
ADDITIONAL SEISMIC LOAD
Line
1
Segment
L
H
H/L Ratio
Load Ratio
Load E
Adj. Load E
Load W
Adj. Load W
Unit Shear E
Unit Shear W
Load (lbs.) Offset Factor
2357 1.00
Total Add. Load
Total Seismic Load =
1
8
8
1.0
1.00
3396
2213
1580
425
198
Max Shear
I
425
psf
Load (lbs)
679 Load Type L Worst Case
1400 Load (plf) 82
0 Length L (ft.) 14
0 Load L (lbs.) 1154
1039 lbs. Total/2 = Wind Load
ADDITIONAL WIND LOAD
Adjust. Load Line Load (lbs.)
2357 1 1635
2357
3396 lbs. Total Wind Load=
SHEAR
PLF I USE# 3 Shear Wall
OVERTURNING
OTM E
OTMW
Wall Weight
Wall UDL
Unif. DL
Concen. DL
COL loc.
DL Moment
DL Mom. E
DLMom. W
Net OT E
NetOTW
Uplift E
Add. Uplift E
UpliftW
Add, Uplift W
Tot. Uplift E
Tot. Uplift W
HD#
27170
17701
16
128
105
7456
3622
4474
23549
13227
2944
1653
2944
1653
1
• -No HD required, by inspection
UPLIFT
•• -See Perforated/ Force-Transfer Shearwall calculation
WIND LOAD
Load Type R
Load (plf)
Length R (ft.)
Load R (lbs.)
577 lbs.
Offset Factor Adjust. Load
1.0 1635
Total Add. Load 1635
2213 lbs.
Worst Case
82
0
Total Shear
Length (ft.)
8
lbs.
lbs.
lbs.
lbs.
plf
plf
Capacity= 490 plf
#-ft,
#-ft.
psf
plf
plf
lbs.
ft.
#-ft.
#-ft,
#-ft.
#-ft,
#-ft.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
L-11
8yAaU0
CBC2306.l
I~ LOVELACE ~ ENGINEERING
STAUCTUAAl. ~NGINE:EAINO iESIYIC~$
MUNDAY RESIDENCE Level Name
JOANNA & TREV MUNDAY Level#
J23320 Lateral Line
FLOOR
1
2
Direction
E-W
L.D.
8/15/2023
Page:
WOOD SHEARWALL ANALYSIS & DESIGN
Area
1
2
3
4
SEISMIC LOAD
sos= 0.816
p = 1.0
Story Load 2.1
SF Factor
320 1.0
660 1.0
545 1.0
Total/2 = Seismic Load
psf
Load (lbs)
679 Load Type L Worst Case
1400 l oad (plf) 82
1156 Length L (ft.) 25
0 Load L (lbs.) 2061
1617 lbs. Total/2 = Wind Load
ADDITIONAL SEISMIC LOAD ADDITIONAL WIND LOAD
Line Load (lbs.) Offset Factor Adjust. Load Line Load (lbs.)
Total Add. Load 0
Total Seismic Load= 1617 lbs. Total Wind Load =
SHEAR
Segment 1 2
4 8
H 7 7
H/L Ratio 1.8 0.9
Load Ratio 0.33 0.67
Load E 539 1078
Adj. Load E
Load W 536 1072
Adj. Load W 383 766
Unit Shear E 135 135
Unit ShearW 96 96
Max Shear 135 PLF USE# 1 Shear Wall
OVERTURNING
OTM E 3774 7S48
OTMW 3752 7503
Wall Weight 16 16
Wall UDL 112 112
Unif. DL
Concen.DL
CDL lot.
DL Moment 896 3584
DLMom. E 435 1741
DLMom. W 538 2150
Net OT E 3339 5807
NetOTW 3214 5353
UPLIFT
Uplift E 835 726
Add. Uplift E
Uplift W 804 669
Add. Uplift W
Tot. Uplift E 835 726
Tot. Uplift W 804 669
HO# •• •• . -No HD required, by inspection .. -See Perforated/ Force-Transfer Shearwall calculation
WIND LOAD
Load Type R Worst Case
Load (plf) 82
Length R (ft.) 14
Load R (lbs.) 1154
1608 lbs.
Offset Factor Adjust. Load
Total Add. Load 0
1608 lbs.
Total Shear
Length (ft.)
12
lbs.
lbs.
lbs.
lbs.
plf
plf
Capacity = 260 plf
#-ft.
#-ft.
psf
plf
plf
lbs.
ft.
#-ft.
11-ft.
#-ft.
#I-ft.
#-ft.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
L-12
By Ratio
CBC 2306 l
I~ LOVELACE ~ ENGINEERING
srRUC1'U■AL !NGINt:f!AING Sl!SllVICI!:$
Shear E
Segment Adj. Shear E
Adjust. Shear E
ShearW
Adjust. Shear W
H above
H opening
H below
Total Height
i
v,,....
OVERTURNING
OTM E
OTM W
Wall Weight
Wall UDL
Uniform DL
DLMoment
DL Moment E
DLMoment W
Net OT E
NetOTW
4.5
7
0
11.S
LI
18600
18491
7
81
285
41119
19974
24671
-1373
-6181
l'
I
1617
1617
1608
1148
Ll (ft.)
4.0
ft.
ft.
ft.
ft.
w
•<plfJ
I I
I
I
b.-ft.
b.-ft.
psf
pit
I
I
I
I
I
pit
b.-ft.
b.-ft.
b.-ft.
b.-ft.
b.-ft.
I
MUNDAY RESIDENCE
JOANNA & TREY MUNDAY
J23320
Level Name
Level#
Lateral Line
FLOOR
1
2
FORCE TRANSFER SHEAR WALL
w (ft.)
3.0
V
Strap Force 1
v'
Strap Force 2
1'
L2
I I I
SHEAR
Net shear to segments, non-adjusted for segment ratio
Segment-adjusted shear per NOS 4.3.4
adjusted for overall H/l ratio of Force-Transfer Shear Wall
Net shear to segments, non-adjusted per CBC 2306.3
Adjusted shear value per CBC 2306.3
L2 (ft.)
8.0
108
108
U S
216
V (IHJ
vclloo.J
Total
Length (ft.)
15
w
77
77
96
153
Perforated
Length (ft.)
12
plf
lbs.
plf
lbs.
Overall
H/L Ratio
0.8
Strap Force
Shear
v<pt,,
Use
Use#
Direction
E-W
Maximum
216
135
CS16
1
[JI JJ II 11 11 11 □W __ ,
UPLIFT
Uplift E
Add. Uplift E
Uplift W
Add. Uplift W
Tot. Uplift E
Tot. Uplift W
HD#
-92
-412
-92
-412
•
I
I
I
I
I
I
bs.
bs.
bs.
bs.
bs.
bs.
• -No HD required, by inspection
L.D.
8/15/2023
Page:
lbs.
plf
strap
Shear Wall
V • VIL
V' • Vll'LI-UJ
L-13
LOVELACE
ENGINEERING
JOB J23320 -MUNDAY RESIDENCE
SHEET NO. ________ F_-_I_ OF _____ _
CALCULATED BY _______ L_.D_._ DATE _____ _
STR UCTURAL ENGIN E E R ING S E RV I CES CHECKED BY __________ DATE _____ _
10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121
phone 858.535.91 11 • fax 858.535.1989 • www.lovelaceeng.com SCALE _________________ _
FOUNDATION DESIGN
ALLOHABLE BEARING PRESSURE, q= 1500 PSF (PER DESIGN CRITERIA)
CONTINUOUS PERIMETER 4 BEARING HALL FOOTINGS:
LOCATION, MAX CONTINUOUS FOOTING
H1= MAX LOAD = 1500 PLF
HIDTH REQ'D= (H 1/q x 12) = i5oo,t5oo x 12 = 12 IN
I USE: 12 11 HIDE X 12 11 DEEP HITH 2 # 4 TOP 4 BOTTOM I
LOCATION : __________________ _
H1 = = PLF
HIDTH REQ 'D= (H1 /q x 12) = = IN
II HIDE X II DEEP HITH TOP 4 BOTTOM I
LOCATION : --------------------H 1 = ____________________ = ___ PL F
HIDTH REQ 'D = (H 1/q x 12) = = IN
I usE, ___ 11 HIDE x ___ 11 DEEP HITH __ # __ ToP 4 BOTTOM I
ISOLATED SPREAD FOOTINGS, ( I-STORY CONT. FTG. POINT LOADS )
MARK, (F-1)
P= CONT. FTG. CAPACITY (MIDV'IALL) = 3000 LBS
A req'd = P/q X 144= 3000,,(500 X 144
USE: IZI PER PAD FOOTING SCHEDULE
MA-RK: (F-2)
P= CONT. FTG. CAPACITY (ENDV'IALL)
A req'd = P/q X 144 = 2250,t500 X 144
USE, [ZI PER PAD FOOTING SCHEDULE
MARK: (F-3)
= 288 SQ IN
= 2250 LBS
= 2 16 SQ IN
P= 18" x 18" x 12 11 DEEP PAD FTG. CAPACITY = 3315 LBS
Areq'd = P/q X 144 = 3315 X 144 = 324 SQ IN
USE: IZI PER PAD FOOTI NG SCHEDULE
12 11x2411 =2881n2
12 "xl8 "=2 16In2
18"x l8 "=324in2
LOVELACE
ENGINEERING
Jos J23320 -MUNDAY RESIDENCE
SHEET NO. F-2 OF -------
CALCULATEDBY _______ L_.D_._ DATE _____ _
STRUCTURAL ENGINEERING SERVICES CHECKEDBY __________ DATE _____ _
10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121
phone858.535.91 11 • fax858.535.1989 • www.lovelaceeng.com SCALE _________________ _
FOUNDATION DESIGN
ALLOHABLE BEARING PRESSURE, q= 1500 PSF (PER DES IGN CRITERIA)
CONTINUOUS PERIMETER 4 BEARING HALL FOOTINGS:
LOCATION, MAX CONTINUOUS FOOTIN6
H1= MAX LOAD = 1815 PLF
HIDTH REQ'D= (H1/q x 12) = 1815 X 12 = 15 IN
I USE: 15 11 HIDE X 18 11 DEEP HITH _2__ # _1_ TOP 4 BOTTOM I
LOCATION: ___________________ _
H 1= ____________________ = ___ PLF
HIDTH REQ'D= (H1 /q x 12) = = IN
IUSE: II DEEP HI TH TOP 4 BOTTOM j
LOCATION: ___________________ _
H 1= ____________________ = ___ PLF
HIDTH REQ'D= (H1/q x 12) = = IN
jusE, ___ 11 HIDE X 11 DEEP HITH __ # __ TOP 4 BOTTOM I
ISOLATED SPREAD FOOTINGS: ( 2-STORY CONT. FTG. POINT LOADS )
MARK: (F-4)
P= CONT. FTG. CAPACITY (MIDHALL) = 5625 LBS
A, .. q'd = p /q X 144= _5_6_12.£l5 ;;n.a.~X~l_!4~4'---_______ ___:::........:....=__ = 540 SQ IN
USE, IZ) PER PAD FOOTING SCHEDULE I5"x36"=540ln2
MA-RK, (F-5)
P= CONT. FTG. CAPACITY (ENDHALL) = 3281 LBS
Areq'd = P/q x 144= _a_1.2~e=!.LL...!x~l4_!.4_!_ ________ ---=--:_:___-= 315 SQ IN
USE: IZ) PER PAD FOOTING SCHEDULE
MARK: (F-6) I5"x2I "=3I5in2
P= 18" x 18" x 18" D EEP PAD FTG. CAPACITY = 3315 LBS
= 324 Areq'd = P/q X 144 = _3_3_15=~x~l_!_4 _!4 _________ =--=____:.___ SQ IN
USE: IZ) PER PAD FOOTING SCHEDULE l811xl8 11 =324in2
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Munday Addition & Alterations
2087 Westwood Drive
Carlsbad, CA 92008
Project Designer:
A Design Shop
3505 Trieste Drive
Carlsbad, CA 92010
760.889.8931
Report Prepared by:
Darrell Hovde
1201 Coe Street
Camarillo, CA 93010
805-444-5029
Job Number:
33329
Date:
8/19/2023
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2022 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC -www.energysoft.com.
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 15
Form MF1 R Mandatory Measures Summary 18
HVAC System Heating and Cooling Loads Summary 23
:
I
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Munday Addition & Alterations
2087 Westwood Drive
Carlsbad, CA 92008
Project Designer:
A Design Shop
3505 Trieste Drive
Carlsbad, CA 92010
760.889.8931
Report Prepared by:
Darrell Hovde
1201 Coe Street
Camarillo, CA 93010
805-444-5029
Job Number:
33329
Date:
8/19/20: CBR2023-4083
2087 WESTWOOD DR
The EnergyPro computer program has been used to perform the calculations s1
authorized by the California Energy Commission for use with both the Residt
MUNDAY; NEW 236 SQ FT ADDITION/ REMODEL KITCHEN
AND NEW MUD ROOM
This program developed by EnergySof
1671800700
8/28/2023
CBR2023-4083
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building
Calculation Description: Title 24 Analysis
GENERAL INFORMATION
01 Project Name Residential Building
02 Run Title Title 24 Analysis
03 Project Location 2087 Westwood Drive
04 City Carlsbad
06 Zip code 92008
08 Climate Zone 7
10 Building Type Single family
12 Project Scope Addition and/or Alteration
14 Addition Cond. Floor Area (ft2) 236
16 Existing Cond. Floor Area (ft2) 2092
18 Total Cond. Floor Area (ft2) 2328
20 ADU Bedroom Count n/a
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 Building does not require field testing or HERS verification
03 Building does not incorporate Special Features -
Calculation Date/Time: 2023-08-19T16:54:02-07:I
Input File Name: 33329.ribd22x
05 Standards Version 2C
07 Software Version En
09 Front Orientation (deg/ Cardinal) 31
11 Number of Dwelling Units 1
13 Number of Bedrooms 4
15 Number of Stories 2
17 Fenestration Average U-factor o.:
19 Glazing Percentage {%) 2C
Registration Number: 423-P010150734A-000-000-0000000-0000 Registration Date/Time: 08/19/2023 16:56 HERS
NOTICE: This document has been generated by California Home Energy Efficiency Ratin9 Services (CHEERS) using information uploaded by third parties not affiliated with or related to Cf and cannot guarantee, the accuracy or completeness of the information contained In this document.
CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version: 2022.0.000 Repo
Sche ma Version: rev 20220901
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building
Calculation Description: Title 24 Analysis
ENERGY USE SUMMARY
Standard Design Source Standard Design TDV Energy
Calculation Date/Time: 2023-08-19T16:54:02-0-Z:I
Input File Name: 33329.ribd22x
Proposed Design Source Proposed Design TDV Energ Energy Use Energy (EDRl} (kBtu/ft2 -yr) (EDRZ) {kTDV/ft2 -yr) Energy (EDRl) (kBtu/ft2 -yr) (EDRZ) (kTDV/ft2 -yr)
Space Heating 0 21.62 0 21.36
Space Cooling 0 17.65 0 17.74
IAQ Ventilation 0 0 0 0
Water Heating 0 27.09 0 27.09
Self
Utilization/Flexibility
Credit
Efficiency Compliance 0 66.36 0 66.19 Total
Photovoltaics 0 0
Battery 0
Flexibility
Indoor Lighting 0 7.5 0 7.5
Appl. & Cooking 0 19.91 0 19.91
Plug Loads 0 28.95 0 28.95
Outdoor Lighting 0 1.76 0 1.76
TOTAL COMPLIANCE 0 124.48 0 124.31
Registration Number: 423-P010150734A-OOO-OOO-OOOOOOO-OOOO Registration Date/Time: 08/19/2023 16:56 HERS
NOTICE: This document has been generated by California Home Energy Efficiency Ratin9 Services (CHEERS) using information uploaded by third parties not affiliated with or related to 0
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version: 2022.0.000 Repo
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2023-08-19Tl6:54:02-07:t
Input File Name: 33329.ribd22x
ENERGY USE INTENSITY
Standard Design {kBtu/ft2 -yr ) Proposed Design {kBtu/ft2 -yr ) Compliance Margin (kBtu/ft2 -yr
Gross EUl1 20.03 20.02 0.01
Net EUl2 20.03 20.02 0.01
Notes
1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.
2. Net EU I is Energy Use Total (including PV) / Total Building Area .
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• NO SPECIAL FEATURES REQUIRED
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performanc
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
BUILDING -FEATURES INFORMATION
01 02 03 04 OS
Project Name Conditioned Floor Area (ft2)
Number of Dwelling Number of Bedrooms Number of Zones Number c
Units Coolin.
Residential Building 2328 1 4 3
-
ZONE INFORMATION
01 02 03 04 05 0
Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heat
Zone 1 Conditioned HVAC Systeml 1158 8 DHW
Zone 2 Conditioned HVAC System! 934 8 DHW
Proposed Addition Zone Conditioned HVAC Systeml 236 8 DHW
Registration Number: 423-P010150734A-000-000-O000000-O000 Registration Date/Time: 08/19/2023 16:56 HERS
NOTICE: This document has been generated by California Home Energy Efficiency Ratin9 Services (CHEERS) using information uploaded by third parties not affiliated with or related to 0 and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version : 2022.0.000 Repo
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building Calculation Date/Time: 2023-08-19T16:54:02-07_:1
Input File Name: 33329.ribd22x Calculation Description: Title 24 Analysis
OPAQUE SURFACES
01 02 03 04 05 06 07 08 09
Name Zone Construction Azimuth Orientation Gross Area (ft2) Window and Tilt (deg) Wall Excep Door Area (ft2)
Front Wall Zone 1 Default Wall Prior to 315 Front 228 91.2 90 197 none
Left Wall Zone 1 Default Wall Prior to 45 Left 48 0 90 197 none
Rear Wall Zone 1 Default Wall Prior to 135 Back 228 151.3 90 197 none
Right Wa ll Zone 1 Default Wall Prior to 225 Right 308 75 90 197 none
Front Wall 2 Zone 2 Default Wall Prior to 315 Front 225.28 36 90 197 none
Left Wall 2 Zone 2 Default Wall Prior to 45 Left 272 18 90 197 none
Rear Wall 2 Zone 2 Default Wall Prior to 135 Back 225.28 39 90 none 197
Right Wall 2 Zone 2 Default Wall Prior to 225 Right 272 35.2 90 none 197
Addition Left Proposed R-15 Wall 45 Left 112.3 6.7 90 Wall Addition Zone none
Addition Rear Proposed R-15 Wall 135 Back 137.7 42 90 Extensic Wall Addition Zone
Proposed
Addition Interior Addition R-15 Walll n/a n/a 137.7 20 n/a Surface Zone» _Ga rag
e -
Interior Surface Proposed R-15 Walll n/a n/a 1 0 n/a Addition Zone
Roof Zone 1 Default Roof Prior to n/a n/a 224 n/a n/a 197
Roof 2 Zone 2 Default Roof Prior to n/a n/a 934 n/a n/a 197
Registration Number: 423-P010150734A-000-000-0000000-0000 Registration Date/Time: 08/19/2023 16:56 HERS
NOTICE: This document has been generated by California Home Energy Effidency Ratinp Services (CHEERS) using information uploaded by third parties not affiliated with or related to Cf
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version: 2022.0.000 Repo
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building Calculation Date/Time: 2023-08-19T16:54:02-07 :I
Input File Name: 33329.ribd22x Calculation Description: Title 24 Analysis
OPAQUE SURFACES
01 02 03 04 OS 06 07 08 09
Name Zone Construction Azimuth Orientation Gross Area (tt2)
Window and Tilt (deg) Wall Excep Door Area (ft2)
Addition Roof Proposed R-30 Roof Attic n/a n/a 236 n/a n/a Addition Zone
Roof3 _Garage_ R-38 HP Attic n/a n/a 494 n/a n/a
Interior Surface Zone 1 R-0 Roof No Attic n/a n/a 140 n/a n/a 2
Interior Surface Zone 2 R-0 Floor No n/a n/a 934 n/a n/a 3 Crawlspace
Front Exterior _Garage_ R-0 Wall 315 Front 152 0 90 Wall none
Left Exterior _Garage_ R-0 Wall 45 Left 152 0 90 Wall none
Rear Exterior _Garage_ R-0 Wall 135 Back 16 0 90 Wall none
Right Exterior _Garage_ R-0Wall 225 Right 48 0 90 none Wall
ATTIC
01 02 03 04 05 06 07 0
Name Construction Type Roof Rise Roof Roof Radiant Cool (x in 12) Reflectance Emittance Barrier
Attic _Garage_ Attic Garage Roof Cons Ventilated 4 0.1 0.85 No N
Attic Zone 1 Attic RoofZone 1 Ventilated 4 0.1 0.85 No N
Attic Zone 2 Attic RoofZone 2 Ventilated 4 0.1 0.85 No N
Attic Proposed Addition Attic Roof Proposed Addition Zone Ventilated 3 0.1 0.85 No N Zone
Registration Number: 423-P010150734A-000-000-0000000-0000 Registration Date/Time: 08/19/2023 16:56 HERS
NOTICE: This document has been generated by California Home Energy Efficiency Ratin9 Services (CHEERS) using information uploaded by third parties not affiliated with or related to Cf
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Sta ndards -2022 Residential Compliance Report Version : 2022.0.000 Repo
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building
Calculation Description: Title 24 Analysis
FENESTRATION/ GLAZING
01 02 03 04 05 06 07 08 09
Orientatio Width Heigh Area Name Type Surface Azimuth (ft) t (ft) Mult. (ft2) n
Window Window Front Wall Front 315 1 71.2
New 8036 Window Rear Wall Back 135 1 28 Window
Window 2 Window Rear Wall Back 135 1 123.
3
Window 3 Window Right Wall Right 225 1 75
Window4 Window Front Wall 2 Front 315 1 36
Window 5 Window Left Wall 2 Left 45 1 18
Window6 Window RearWall 2 Back 135 1 39
Window7 Window Right Wall 2 Right 225 1 35.2
Addition Addition Left 2034 Window Wall Left 45 1 6.7
Window
Addition Addition 6070 Sliding Window Rear Wall Back 135 1 42
Gia
Calculation Date/Time: 2023-08-19T16:54:02-07.:I
Input File Name: 33329.ribd22x
10 11 12 13
U-factor U-factor Source SHGC SHGC Sou rce
1.19 Table 0.83 Table
110.6-A 110.6-B
0.3 NFRC 0.23 NFRC
0.3 NFRC 0.23 NFRC
1.19 Table 0.83 Table
110.6-A 110.6-B
1.19 Table 0.83 Table
110.6-A 110.6-B
1.19 Table 0.83 Table
110.6-A 110.6-B
1.19 Table 0.83 Table
110.6-A 110.6-B
1.19 Table 0.83 Table
110.6-A 110.6-B
0.3 NFRC 0.23 NFRC
0.3 NFRC 0.23 NFRC
Registration Number: 423-P010150734A-000-000-0000000-0000 Registration Date/Time: 08/19/2023 16:56 HERS
NOTICE: This document has been generated by California Home Energy Efficiency Ratinf} Services (CHEERS) using information uploaded by third parties not affiliated with or related to Cf and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version: 2022.0.000 Repo
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building Calculation Date/Time: 2023-08-19Tl6:54:02-07:I
Input File Name: 33329.ribd22x Calculation Description: Title 24 Analysis
OPAQUE DOORS
01 02 03 04 OS
Name Side of Building Area (ft2) U-factor Status
Door Front Wall 20 0.5 Existing
Addition 3068 Door Addition Interior Surface 20 0.2 New
SLAB FLOORS
01 02 03 04 OS 06 07 08
Edge lnsul. Edge lnsul.
Name Zone Area (ft2) Perimeter (ft) R-value and R-value and Carpeted Fraction Heated
Depth Depth
Slab Zone 1 1158 134 none 0 80% No
Addition Slab Proposed 236 66.3 none 0 80% No Addition Zone
Slab-on-Grade _Garage_ 494 0.1 none 0 0% No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 OS 06 07
Total Cavity Interior/ Exterior
Construction Name Surface Type Construction Type Framing Continuous U-factor R-value R-value
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. 0. C. R-0 None/ None 0.361
Default Wall Prior to Exterior Walls Wood Framed Wall 2x4 @ 16 in. 0 . C. R-0 None I None 0.361 197
R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in . 0 . C. R-15 None I None 0.095
Registration Number: 423-P010150734A-000-000-0000000-0000 Registration Date/Time: 08/19/2023 16:56 HERS
NOTICE: This document has been generated by California Home Energy Effidency Ratin9 Services (CHEERS) using information uploaded by third parties not affiliated with or related to Cf
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version: 2022.0.000 Repo
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building Calculation Date/Time: 2023-08-19T16:54:02-07.:I
Input File Name: 33329.ribd22x Calculation Description: Title 24 Analysis
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07
Total Cavity Interior/ Exterior
Construction Name Surface Type Construction Type Framing Continuous U-factor R-va lue R-value
R-15 Walll Interior Walls Wood Framed Wall 2x4 @ 16 in. 0 . C. R-15 None/ None 0.086
Attic Garage Roof Cons Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-19 None/ 0 0.059 Ceiling
Attic RoofZone 1 Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-0 None/ 0 0.644 Ceiling
Attic RoofZone 2 Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-0 None/ 0 0.644 Ceiling
" .
Attic Roof Proposed Attic Roofs Wood Framed 2x4 @ 24 in. O. C. R-0 None/ 0 0.644 Addition Zone Ceiling
R-38 HP Attic Ceilings {below Wood Framed 2x4 @ 24 in. 0. C. R-38 None/ None 0.025 attic) Ceiling
Default Roof Prior to Ceilings {below Wood Framed 2x4 @ 16 in. 0. C. R-11 None/ None 0.083 197 attic) Ceiling
Registration Number: 423-P010150734A-000-000-0000000-0000 Registration Date/Time: 08/19/2023 16:56 HERS
NOTICE: This document has been generated by California Home Energy Efficiency Ratin9 Services (CHEERS) using information uploaded by third parties not affiliated with or related to Cf and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards -2022 Residential Compliance Report Vers ion: 2022.0.000 Repo
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building Calculation Date/Time: 2023-08-19Tl6:54:02-07:I
Input File Name: 33329.ribd22x Calculation Description: Title 24 Analysis
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 OS 06 07
Total Cavity Interior/ Exterior
Construction Name Surface Type Construction Type Framing Continuous U-factor R-value R-value
.
R-30 Roof Attic Ceilings (below Wood Framed 2x4 @ 24 in. 0. C. R-30 None/ None 0.032 attic) Ceiling
I
R-0 Floor No Crawlspace Interior Floors Wood Framed Floor 2x12 @ 16 in. 0. C. R-0 None/ None 0.196
R-0 Roof No Attic Interior Ceiling Wood Framed 2x4 @ 16 in. 0. C. R-0 None/ None 0.202 Ceiling
BUILDING ENVELOPE -HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII} High R-value Spray Foam Insulation Building Envelope Air Leakage CFMS0
Not Required Not Required N/A n/a
.
WATER HEATING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Distribution Water Heater Number of Solar Heating Compact HERS Water Heater SI Type Name Units System Distribution Verification Name(#}
Domestic DHW Heater DHW Heater DHW Sys 1 Hot Water Standard 1 1 n/a None n/a 1 (1) Ex
(DHW)
Registration Number: 423-P010150734A-000-000-0000000-0000 Registration Date/Time: 08/19/2023 16:56 HERS
NOTICE: This document has been generated by California Home Energy Efficiency Ratinr, Services (CHEERS) using information uploaded by third parties not affiliated with or related to Cf and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version: 2022.0.000 Repo
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building Calculation Date/Time: 2023-08-19Tl6:54:02-07.:I
Input File Name: 33329.ribd22x Calculation Description: Title 24 Analysis
WATER HEATERS
01 02 03 04 OS 06 07 08 09 10 11 12
Heating Heating Input Tank Standby 1st Hr. # of Tank Vol . Rated Insulation Loss or Name Element Tank Type Units (gal) Efficiency Efficiency Input Type Rating or R-value Recovery Rating or
Type Type Pilot (Int/Ext) Eff Flow Rate
DHW Gas Small Storage 1 so Heater 1 EF 0.57 Btu/Hr 75000 0 80
WATER HEATING -HERS VERIFICATION
01 02 03 04 OS 0
Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Recirculati Type
DHW Sys 1 -1/1 Not Required Not Required Not Required None Not Re
SPACE CONDITIONING SYSTEMS
01 02 03 04 OS 06 07 08 09
Heating Unit Heating Cooling Unit Cooling Distribution Required
Name System Type Equipment Equipment Fan Name Thermostat S1 Name Count Name Count Name Type
HVAC Heating and Heating Cooling Air
Systeml cooling Component 1 Component 1 HVAC Fan 1 Distribution n/a Ex
system other 1 1 System 1
-
HVAC -HEATING UNIT TYPES
01 02 03
Name System Type Number of Units
Heating Component 1 Electric 1
Registration Number: 423-P010150734A-000-000-0000000-0000 Registration Date/Time: 08/19/2023 16:56 HERS
NOTICE: This document has been generated by California Home Energy Efficiency Ratinfl Services (CHEERS) using Information uploaded by third parties not affiliated with or related to 0 and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version : 2022.0.000 Repo
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building Calculation Date/Time: 2023-08-19Tl6:54:02-07:I
Input File Name: 33329.ribd22x Calculation Description: Title 24 Analysis
HVAC -COOLING UNIT TYPES
01 02 03 04 05 06 07
Name System Type Number of Units Efficiency Metric Efficiency Efficiency Zonally Controlled EER/EER2/CEER SEER/SEER2
Cooling Central split AC 1 Component 1 EER2/SEER2 11.7 14 Not Zonal
HVAC -DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12 13
Duct Ins. Duct Surface Area R-value Location HERS Name Type Design Type Bypass Duct Duct Leakage Verification Status
Suppl Retur Suppl Retur Suppl Retur I
y n y n y n
Air Existing Air
Unconditio Non-Atti Atti No Bypass Distribution Distribution R-6 R-6 n/a n/a (not Existing
System 1 ned attic Verified C C Duct specified) System
1-hers-dist
HVAC-FAN SYSTEMS
01 02 03
Name Type Fan Power (Watts/CFM)
HVAC Fan 1 HVAC Fan 0.45
HVAC FAN SYSTEMS -HERS VERIFICATION
01 02
Name Verified Fan Watt Draw Require
HVAC Fan 1-hers-fan Not Required
Registration Number: 423-P010150734A-000-000-0000000-0000 Registration Date/Time: 08/19/2023 16:56 HERS
NOTICE: This document has been generated by California Home Energy Efficiency Ratin9 Services (CHEERS) using information uploaded by third parties not affiliated with or related to 0
and cannot guarantee, the accuracy or completeness of the Information contained in this document.
CA Building Ene rgy Efficiency Standards -2022 Residential Compliance Report Version: 2022.0.000 Repo
Schema Version : rev 20220901
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residential Building
Calculation Description: Title 24 Analysis
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Darrell Hovde
Company:
Hovde Engineering Inc
Address:
1201 Coe Street
City/State/Zip:
Camarillo, CA 93010
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
Calculation Date/Time: 2023-08-19Tl6:54:02-07j
Input File Name: 33329.ribd22x
Documentation Author Signature:
V a-vve,ll; tl o-vd,e;
Signature Date:
08/19/2023
CEA/ HERS Certification Identification (If applicable):
RCN13803
Phone:
(805) 388-7689
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of ntle 24, Part 1 and P;
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicabl
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name: Responsible Designer Signature:
Darrell Hovde Va-vve,U; tl o-vd€/
Company: Date Signed:
Hovde Engineering Inc 08/19/2023
Address: License:
1201 Coe Street M26054, CA
City/State/Zip: Phone:
Camarillo, CA 93010 (805) 388-7689
Di(litally signed by California Home Energy Efficiency Rating Services (CHEERS).. This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 423-P010150734A-000-000-0000000-0000 Registration Date/Time: 08/19/2023 16:56 HERS
NOTICE: This document has been generated by California Home Energy Efficiency Ratin9 Services (CHEERS) using information uploaded by third parties not affiliated with or related to O and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards -2022 Residentia l Compliance Report Version : 2022.0.000 Repo
Schema Version: rev 20220901
RESIDENTIAL MEASURES SUMMARY RMS-1
Project Nam e Building Type Gil Single Family □ Addition Alone I Date
Munday Addition & Alterations □ Multi Family [;zl Existing+ Addition/Alteration 8/19/2023
Project Address California Energy Climate Zone I Total Cond. Floor Area I Addition I #of tits
2087 Westwood Drive Carlsbad CA Climate Zone 07 2,328 236
INSULATION Area
Construction Type Cavity (ff) Special Features Status
Wall Wood Framed -no insulation 137 Existing
Door Opaque Door -no insulation 20 Existing
Wall Wood Framed -no insulation 48 Existing
Wall Wood Framed -no insulation 77 Existing
Wall Wood Framed -no insulation 233 Existing
Roof Wood Framed Attic R 11 224 Existing
Slab Unheated Slab-on-Grade -no insulation 1,158 Perim = 134' Existing
Demising Wood Framed Rafter -no insulation 140 Existing
FENESTRATION I Total Area: 4741 Glazing Percentage: 20.4% I New/Altered Average U-Factor: 0.30
Orientation Area(ff) U-Fac SHGC Overhang Sidefins Exterior Shades Status
Front (NW) 107.2 1.190 0.83 none none NIA Existing
Rear (SE) 70.0 0.300 0.23 none none NIA New
Rear (SE) 123.3 0.300 0.23 none none NIA Existing
Right (SW) 110.2 1.190 0.83 none none NIA Existing
Left (NE) 18.0 1.190 0.83 none none NIA Existing
Rear (SE) 39.0 1.190 0.83 none none NIA Existing
Left (NE) 6.7 0.300 0.23 none none NIA New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 No Heating Provided nla Split Air Conditioner 14.0 SEER2 Setback Existing
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
HVAC System Ducted Ducted Attic 6.0 Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EneravPro 9. 1 bv EneravSoft User Number: 4403 ID: 33329 Paae 15 of 23
RESIDENTIAL MEASURES SUMMARY RMS-1
Project Name Building Type Gil Single Family □ Addition Alone I Date
Munday Addition & Alterations □ Multi Family Gil Existing+ Addition/Alteration 8/19/2023
Project Address California Energy Climate Zone I Total Cond. Floor Area I Addition I # of ~nits
2087 Westwood Drive Carlsbad CA Climate Zone 07 2,328 236
INSULATION Area
Construction Type Cavity (ff) Special Features Status
Wall Wood Framed -no insulation 189 Existing
Wall Wood Framed -no insulation 254 Existing
Wall Wood Framed -no insulation 186 Existing
Wall Wood Framed -no insulation 237 Existing
Roof Wood Framed Attic R 11 934 Existing
Demising Wood Framed wl o Crawl Space -no insulation 934 Existing
Wall Wood Framed R 15 107 New
Wall Wood Framed R 15 96 New
FENESTRATION I Total Area: 474 I GlazinQ PercentaQe: 20.4% I New/Altered AveraQe U-Factor: 0.30
Orientation Area(ff) U-Fac SHGC Overhang Sidefins Exterior Shades Status
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EneravPro 9. 1 bv EneravSoft User Number: 4403 ID: 33329 Paae 16 of 23
RESIDENTIAL MEASURES SUMMARY RMS-1
Project Name Building Type G2I Single Family D Addition Alone I Date
Munday Addition & Alterations D Multi Family l;i:'I Existing+ Addition/Alteration 8/19/2023
Project Address California Energy Climate Zone I Total Cond. Floor Area I Addition I #oftits 2087 Westwood Drive Carlsbad CA Climate Zone 07 2,328 236
INSULATION Area
Construction Type Cavity (ff) Special Features Status
Roof Wood Framed Attic R30 236 New
Slab Unheated Slab-on-Grade -no insulation 236 Perim = 66' New
Demising Wood Framed R 15 118 Altered
FENESTRATION I Total Area: 474 I Glazing Percentage: 20.4% I New/Altered Average U-Factor: 0.30
Orientation Area(ff) U-Fac SHGC Overhang Sidefins Exterior Shades Status
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EneravPro 9. 1 bv EneravSoft User Number: 4403 ID: 33329 Paae 17 of 23
2022 Single-Family Residential Mandatory Requirements Summary
NOTE: Single-family residential buildings subject to the Energy Codes must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information.
(0412022)
Building Envelope:
§ 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or
less when tested per NFRC-400, ASTM E283, or AAMANJDMA/CSA 101/I.S.2/A440-2011 . *
§ 110.6(a)5: Labeling. Fenestration products and exterior doors must have a label meeting the requirements of§ 10-111 (a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from
Tables 110.6-A, 110.6-B, or JA4.5 for exterior doors. They must be caulked and/or weather-stripped.•
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be
caulked, qasketed, or weather stripped.
§ 110.8(a): Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household
Goods and Services (BHGS).
§ 110.8(9): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of§ 110.8(9).
§ 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the
roofing material must meet the requirements of§ 110.8(i) and be labeled per§ 10-113 when the installation of a cool roof is specified
on the CF1R.
§ 110.80): Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer
Affairs.
Roof Deck, Ceiling and Rafter Roof Insulation. Roof decks in newly constructed attics in climate zones 4 and 8-16 area-weighted
average U-factor not exceeding U-0.1 84. Ceiling and rafter roofs minimum R-22 insulation in wood-frame ceiling; or area-weighted average
§ 150.0(a): U-factor must not exceed 0.043. Rafter roof alterations minimum R-19 or area-weighted average U-factor of 0.054 or less. Attic access
doors must have permanently attached insulation using adhesive or mechanical fasteners . The attic access must be gasketed to
prevent air leakage. Insulation must be installed in direct contact with a roof or ceiling which is sealed to limit infiltration and exfiltration
as specified in & 110.7, includinq but not limited to placinq insulation either above or below the roof deck or on top of a drvwall ceilinq. •
§ 150.0(b): Loose-fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood
§ 150.0(c): framing or have a U-factor of 0.071 or less. Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102.
Masonrv walls must meet Tables 150.1-A or B. •
§ 150.0(d): Raised-floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor. *
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone
§ 150.0(0: without facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from
physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of§ 110.8(9).
§ 150.0(g)1 :
Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II
vapor retarder. This requirement also applies to controlled ventilation crawl space for buildings complying with the exception to
&150.0(d).
§ 150.0(g)2:
Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of
all insulation in all exterior walls, vented attics, and unvented attics with air-permeable insulation.
§ 150.0(q): Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have
a maximum U-factor of 0.45; or area-weighted average U-factor of all fenestration must not exceed 0.45. •
Fireplaces, Decorative Gas Appliances, and Gas Loq:
§ 110.5(e) Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces.
§ 150.0(e)1 : Closable Doors. Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)2: Combustion Intake. Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in
area and is equipped with a readily accessible, operable, and tiqht-fittinq damper or combustion-air control device.•
§ 150.0(e)3: Flue Damper. Masonry or factory-built fireplaces must have a flue damper with a readily accessible control. •
Space Conditioning, Water Heating, and Plumbing System:
§ 110.0-§ 110.3: Certification. Heating, ventilation, and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other
requlated appliances must be certified by the manufacturer to the California Enerqy Commission. •
§ 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-N.
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance
§ 110.2(b): heaters must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone;
and in which the cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and
the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating. •
§ 110.2(c): Thermostats. All healing or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat. *
& 110.3(c)3:
Insulation. Unfired service water heater storage tanks and solar water-healing backup tanks must have adequate insulation, or tank
surface heat loss rating.
§ 110.3(c)6: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with
hose bibbs or other fittinqs on both cold and hot water lines to allow for flushinq the water heater when the valves are closed.
5/6/22
. § 110.5:
§ 150.0(h)1:
§ 150.0(h)3A:
§ 150.0(h)3B:
§ 150.00)2:
§ 150.0(n)1 :
§ 150.0(n)3:
Ducts and Fans:
§ 110.8(d)3:
§ 150.0(m)1 :
§ 150.0(m)2:
§ 150.0(m)3:
§ 150.0(m)?:
§ 150.0(m)8:
§ 150.0(m)9:
§ 150.0(m)10:
§ 150.0(m) 11:
§ 150.0(m)12:
5/6/22
2022 Single-Family Residential Mandatory Requirements Summary
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces; household cooking appliances
(except appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour); and pool and
s a heaters.•
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook,
Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation
Standards Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2.
Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any
d er.
Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the
manufacturer's instructions.
Water Piping, Solar Water-heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water
i in must be insulated ass ecified in 609.11 of the California Plumbin Code. *
Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment'
maintenance, and wind as required by §120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no
adhesive tapes). Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must
include, or be protected by, a Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and
non-crushable casin or sleeve.
Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must
designate a space at least 2.5' x 2.5' x 7' suitable for the future installation of a heat pump water heater, and meet electrical and
plumbing requirements, based on the distance between this designated space and the water heater location; and a condensate drain no
more than 2" hi her than the base of the water heater
Solar Water-heating Systems. Solar water-heating systems and collectors must be certified and rated by the Solar Rating and
Certification Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO
R&T), or by a listing agency that is approved by the executive director.
Ducts. Insulation installed on an existing space-conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air-distribution system ducts and plenums must meet CMC §§ 601.0-605.0 and ANSI/SMACNA-006-2006 HVAC
Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply-air and return-air ducts and plenums must be insulated to
R-6.0 or higher; ducts located entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3. 1.4.3.8)
do not require insulation. Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be
sealed with mastic, tape, or other duct-closure system that meets the applicable UL requirements, or aerosol sealant that meets UL 723.
The combination of mastic and either mesh or tape must be used to seal openings greater than ¼", If mastic or tape is used. Building
cavities, air handler support platforms, and plenums designed or constructed with materials other than sealed sheet metal, duct board or
flexible duct must not be used to convey conditioned air. Building cavities and support platforms may contain ducts; ducts installed in
these spaces must not be compressed. •
Factory-Fabricated Duct Systems. Factory-fabricated duct systems must comply with applicable requirements for duct construction,
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive
duct tapes unless such tape is used in combination with mastic and draw bands.
Field-Fabricated Duct Systems. Field-fabricated duct systems must comply with applicable requirements for: pressure-sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic
dampers.
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage due tosunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather must be suitable for outdoor service (e.g., protected by aluminum, sheet metal, painted canvas, or plastic
cover). Cellular foam insulation must be protected as above or painted with a water retardant and solar radiation-resistant coating.
Porous Inner Core Flex Duct. Porous inner cores of flex ducts must have a non-porous layer or air barrier between the inner core and
outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing , in
accordance with Reference Residential Appendix RA3.1 .
Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13
or equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A.
Clean-filter pressure drop and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service. Filter
racks or grilles must use gaskets, sealing, or other means to close gaps around the inserted filters to and prevents air from bypassing the
filter.*
§ 150.0(m)13:
2022 Single-Family Residential Mandatory Requirements Summary
Space Conditioning System Airflow Rate and Fan Efficacy. Space condition ing systems that use ducts to supply cooling must have
a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must
be 2: 350 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy :S 0.45 watts per CFM for gas furnace air
handlers and :S 0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow 2: 250 CFM per ton of nominal
cooling capacity, and an air-handling unit fan efficacy :S 0.62 watts per CFM. Field verification testing is required in accordance with
Reference Residential Appendix RA3.3. •
Ventilation and Indoor Air Qualitv:
§ 150.0(o)1 : Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASH RAE Standard 62.2,
Ventilation and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in§ 150.0(o)1. •
§ 150.0(o)1B: Central Fan Integrated (CFI) Ventilation Systems. Continuous operation of CFI air handlers is not allowed to provide the whole-
dwelling unit ventilation airflow required per §150.0(o)1 C. A motorized damper(s) must be installed on the ventilation duct(s) that
prevents all airflow through the space conditioning duct system when the damper(s) is closed andcontrolled per §150.0(o)1 Biii&iv. CFI
ventilation systems must have controls that track outdoor air ventilation run time, and either open or close the motorized damper(s) for
compliance with §150.0(o)1C.
Whole-Dwelling Unit Mechanical Ventilation for Single-Family Detached and townhouses. Single-family detached dwelling units,
§ 150.0(o)1C: and attached dwelling units not sharing ceilings or floors with other dwelling units, occupiable spaces, public garages, or commercial
spaces must have mechanical ventilation airflow specified in § 150.0( o) 1 Ci-iii.
§ 150.0(o)1G: Local Mechanical Exhaust. Kitchens and bathrooms must have local mechanical exhaust; nonenclosed kitchens must have demand-
controlled exhaust system meeting requirements of §150.0(o)1Giii,enclosed kitchens and bathrooms can use demand-controlled or
continuous exhaust meeting §150.0(o)1Giii-iv. Airflow must be measured by the installer per §150.0(o)1 Gv, and rated for sound per
&150.0(o)1Gvi. •
§ 150.0(o)1H&I: Airflow Measurement and Sound Ratings of Whole-Dwelling Unit Ventilation Systems. The airflow required per§ 150.0(o)1C must
be measured by using a flow hood, flow grid, or other airflow measuring device at the fan's inlet or outlet terminals/grilles per Reference
Residential Appendix RA3.7. Whole-Dwelling unit ventilation systems must be rated for sound per ASHRAE 62.2 §7.2 at no less than the
minimum airflow rate reauired bv &150.0(o)1C.
Field Verification and Diagnostic Testing. Whole-Dwelling Unit ventilation airflow, vented range hood airflow and sound rating,
§ 150.0(o)2: and HRV and ERV fan efficacy must be verified in accordance with Reference Residential Appendix RA3.7. Vented range hoods
must be verified per Reference Residential Appendix RA3. 7.4.3 to confirm if it is rated by HVI or AHAM to comply with the airflow
rates and sound requirements per §150.0(o)1G
Pool and Spa Systems and Equipment·
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: compliance
§ 110.4(a): with the Appliance Efficiency Regulations and listing in MAEDbS; an on-off switch mounted outside of the heater that allows shutting off
the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not
use electric resistance heatina. •
§ 110.4(b)1: Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or
dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b )3: Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time
switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
§ 150.0(p): Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump
sizinQ, flow rate, pipina, filters, and valves. •
Liahtina:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable
§ 110.9: reauirements of§ 110.9. •
§ 150.0(k)1A: Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A, except lighting integral to exhaust fans, kttchen
range hoods, bath vanity mirrors, and garage door openers; navigation lighting less than 5 watts; and lighting internal to drawers, cabinets, and linen
closets wtth an efficacy of at least 45 lumens per watt.
§ 150.0(k)1B: Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JAB. •
§ 150.0(k)1C: Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must not contain screw based sockets, must be airtight,
and must be sealed with a gasket or caulk. California Electrical Code § 410.116 must also be met.
§ 150.0(k)1D: Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JAB
elevated temperature reauirements, including marking requirements, must not be installed in enclosed or recessed luminaires.
§ 150.0(k) 1 E: Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a
luminaire or other device shall be no more than the number of bedrooms. These boxes must be served by a dimmer, vacancy sensor
control, low voltaae wirina, or fan speed control.
§ 150.0(k)1F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust
hoods) must meet the aoolicable requirements of§ 150.0(k). •
5/6/22
2022 Single-Family Residential Mandatory Requirements Summary
§ 150.0(k)1G: Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JAB. •
Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JAB
§ 150.0(k)1H: elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires.
§ 150.0(k)1I: Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required
to comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of
power, emit no more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or
linen closet is closed.
§ 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)28: Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems. •
§ 150.0(k)2A: Accessible Controls. Lighting must have readily accessible wall-mounted controls that allow the lighting to be manually turned
on and off.•
§ 150.0(k)28: Multiple Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the dimmer or sensor is installed
to comply with§ 150.0(k).
§ 150.0(k)2C: Mandatory Requirements. Lighting controls must comply with the applicable requirements of§ 110.9.
Energy Management Control Systems. An energy management control system (EMCS) may be used to comply with dimming,
§ 150.0(k)2D: occupancy, and control requirements if it provides the functionality of the specified control per§ 110.9 and the physical controls specified
in § 150.0(k)2A.
Automatic Shutoff Controls. In bathrooms, garages, laundry rooms, utility rooms and walk-in closets, at least one installed luminaire
§ 150.0(k)2E: must be controlled by an occupancy or vacancy sensor providing automatic-off functionality. Lighting inside drawers and cabinets with
opaque fronts or doors must have controls that turn the light off when the drawer or door is closed.
§ 150.0(k)2F: Dimmers. Lighting in habitable spaces (e.g., living rooms, dining rooms, kitchens, and bedrooms) must have readily accessible wall-
mounted dimming controls that allow the lighting to be manually adjusted up and down. Forward phase cut dimmers controlling LED light
sources in these spaces must comply with NEMA SSL 7A.
§ 150.0(k)2K: Independent controls. Integrated lighting of exhaust fans shall be controlled independently from the fans. Lighting under cabinets or
shelves, liqhtinq in disolav cabinets, and switched outlets must be controlled separately from ceiling-installed lighting.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to
§ 150.0(k)3A: other buildings on the same lot, must have a manual on/off switch and either a photocell and motion sensor or automatic time switch
control) or an astronomical time clock. An energy management control system that provides the specified control functionality and meets all
applicable requirements may be used to meet these requirements.
§ 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must either comply with§ 140.8 or consume no more than 5
watts of power.
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements fornonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0.
Solar Readiness:
Single-family Residences. Single-family residences located in subdivisions with 10 or more single-family residences and where the
§ 110.10(a)1 : application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency,
which do not have a photovoltaic system installed, must comply with the requirements of§ 110.10(b)-(e).
Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with
access, pathway, smoke ventilation , and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any
requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5
feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160
§110.10(b)1A: square feet each for buildings with roof areas greater than 10,000 square feet. For single-family residences, the solar zone must be
located on the roof or overhang of the building and have a total area no less than 250 square feet. .
§ 110.10(b)2: Azimuth. All sections of the solar zone located on steep-sloped roofs must have an azimuth between 90-300° of true north.
§ 110.1 O(b)3A: Shading. Th~ solar zpne must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)38: horizontal distance of the height difference _between the highest point of the obstruction and the horizontal projection of the nearest point of the
solar zone, measured in the vertical plane.
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for
roof dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a
§ 110.10(c): pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single-family
residences and central water-heatina svstems, a pathway reserved for routina plumbing from the solar zone to the water-heating system.
§ 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from§ 110.1 O(b)-(c) must be
provided to the occupant.
§ 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
§ 110.10(e)2: Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole
circuit breaker for a future solar electric installation. The reserved space must be permanently marked as "For Future Solar Electric."
Electric and Energy Storage Ready:
5/6/22
§ 150.0(s)
§ 150.0(1)
§ 150.0(u)
§ 150.0(v)
2022 Single-Family Residential Mandatory Requirements Summary
Energy Storage System (ESS) Ready. All single-family residences must meet all of the following: Either ESS-ready interconnection
equipment with backed up capacity of 60 amps or more and four or more ESS supplied branch circuits, Q[ a dedicated raceway from the
main service to a subpanel that supplies the branch circuits in § 150.0(s); at least four branch circuits must be identified and have their
source collocated at a single panelboard suitable to be supplied by the ESS, with one circuit supplying the refrigerator, one lighting circuit
near the primary exit, and one circuit supplying a sleeping room receptacle outlet; main panelboard must have a minimum busbar rating of
225 amps; sufficient space must be reserved to allow future installation of a system isolation equipment/transfer switch within 3' of the main
anelboard, with racewa s installed between the anelboard and the switch location to allow the connection of backu ower source.
Heat Pump Space Heater Ready. Systems using gas or propane furnaces to serve individual dwelling units must include: A dedicated
unobstructed 240V branch circuit wiring installed within 3' of the furnace with circuit conductors rated at least 30 amps with the blank cover
identified as "240V ready;" and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker
ermanentl marked as "For Future 240V use."
Electric Cooktop Ready. Systems using gas or propane cooktop to serve individual dwelling units must include: A dedicated unobstructed
240V branch circuit wiring installed within 3' of the cooktop with circuit conductors rated at least 50 amps with the blank cover identified as
"240V ready;" and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently
marked as "For Future 240V use."
Electric Clothes Dryer Ready. Clothes dryer locations with gas or propane plumbing to serve individual dwelling units must include: A
dedicated unobstructed 240V branch circuit wiring installed within 3' of the dryer location with circuit conductors rated at least 30 amps with
the blank cover identified as "240V ready;" and a reserved main electrical service panel space to allow for the installation of a double pole
circuit breaker ermanentl marked as "For Future 240V use ."
*Exceptions may apply.
5/6/22
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name Date
Munday Addition & Alterations 8/19/2023
System Name Floor Area
HVAC System 2,328
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK
Heating System CFM Sensible Latent CFM Sensible
Output per System 0 Total Room Loads 2,173 43,854 1,386 1,465 55,300
Total Output (Btuh) 0 Return Vented Lighting 0
Output (Btuh/saftl 0.0 Return Air Ducts 1,61 0 2,716
Cooling System Return Fan 0 0
Output per System 1 Ventilation 0 0 0 0 0
Total Output (Btuh) 1 Supply Fan 0 0
Total Output (Tons) 0.0 Supply Air Ducts 1,610 2,716
Total Output (Btuh/saftl 0.0
Total Output (sqft/Ton) 27,936,000.0 TOTAL SYSTEM LOAD 47,074 1,386 60,732
Air System
CFM per System 0 HVAC EQUIPMENT SELECTION
Airflow (cfm) 0 Furnace -A/C 1 0 0
Airflow (cfm/saft) 0.00
Airflow (cfm/Ton) 0.0
Outside Air(%) 0.0% Total Adjusted System Output 1 0 0
Outside Air (cfm/sqft) 0.00 (Adjusted for Peak Design conditions)
Note: values above given at ARI conditions TIME OF SYSTEM PEAK Aug 3 PM I Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak)
34 °F 66 °F 105 Of
--~ ·i ~~-,]~]-_~
Outside Air i ~~ 0 cfm Heating Coil 103 °F ..
ROOM JI
66 °F 68 °F
-~ ~ I t L C~ I ---
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak)
83161°F 76 / 62 °F 55 / 54 °F
~ --_B -~~7-_] -. • li i Outside Air ~..-
0 cfm Cooling Coil 56 I 54 °F
~ ..
ROOM--lll 46.5% !
76 I 62 °F 75 I 62 °F
~ ---~ 1 t 1 ~~ I --
STORM WATER POLLUTION PREVENTION NOTES
1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE
AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION
OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN
IS EMINENT.
2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION
CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION
OF THE CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING
RAINFALL.
3. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION
CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY
INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR
UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE.
4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE
AT THE END OF EACH WORKING DAY WHEN THE FIVE (5)
DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT
( 40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER
EACH RAINFALL
5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM
AGGREGATE.
6. AOEQUA TE EROSION ANO SEDIMENT CONTROL ANO PERIMETER
PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST
BE INSTALLED AND MAINTAINED.
7. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER
THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED
TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY
REGULATIONS.
OWNER' CERTIFICATE:
I UNDERSTAND AND ACKNO\\\.EDGE THAT I MUST: (1) IMPLEMENT
BEST MANAGEMENT PRACTICES {BMPS) DURING CONSTRUCTION
.~CTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID
THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO
AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION
RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES,
COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP
THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES
UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED
BY ~E CITY OF CARLSBAD. . (
'(;._ b'i1i
D TE
E-29
STORM WATER COMPLIANCE FORM
TIER 1 CONSTRUCTION SWPPP
E-29
BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE
CB
SW
Erosion Control Sediment Control BMPs Tracking Non-Stam, Waler Waste Management and Materials
BMPs ControlBMPs Management BMPs Polution Control BMPs
C C a C 0 1 :g C g ~ :? ., g E ,, " C 0, K a 0 .; .s .2 ~ { ., ;;; :::E ,, "' 5 "' I ·5 >-"' .,
"' CU C. C ., E "'"' ~ CT g C
Oo C «> C w -~ .2 0 "' Best Management Practice· -l! C "' 0 DJ ·g-0" 0 ., 0 3'-o-
" £ "'"' .£ ,!= § "' 0 C u 5, u .,, ., ~ .., ,; "' :::E i .,c C 3' Ii; (BMP) Description ➔ ., V1 ., "' ., "' DJ C C 0 :::, -" "'., 3 ~., 0 0 3' C i!la!. 0" CC 0 l3 E " C 0 0 DJ en 0 0 "' .!! ., => E ., E ~] i ~~ 0 vi .E :::E 0 g' C e "' 0 N «> u::i -f~
., Q> C :g g' 0 t <t] 3' ., 0., -., .,, ., ~ X l -=> .D E.!? = II) =3: ~:;:;; ~ v·c ] 0, ~~ t g' =-~ " ~ ., => g :c ~ ~g "" .,, 0 g 0 C. ~ b~ ~~ ~o ~ 0 " 0 00 -o 0 :=°C ~g 0 0 ~ 0 .c 0 vi a: ~E £ct 0 a. o_ in 0. 0 c:, ~ WO vi in V1 u [;: Vl> V1 V)"' a.o a. :::E V1 :::E VlU V1 :::E
CASOA Des~nation ➔ ,.._ <0 0, ::: .., ... "' "'
,.._ 00 0 N .., ,.._ co ' N .., ... ,n
I I I I ' I I J., I I J., J., ' I ' I I I I I I I u u u '-' w w w w w e: e: V1 V1 V1 V1 i i i i i Construction AeJvily w w w w V1 V1 V1 V1 V1 V1 V1 V1 z z z z
Grodina/Soil Disturbance ~
Trenchina/Excovotion "" Stockoilino
Drillina /Barino
Concrete/Asphalt Sowcuttina ::,,f!"
Concrete Flotwork
Paving
Conduit/Pipe Installation "' Stucco/Mortar Work
Waste Disposal
Slooino /l oy Down Areo
Equipment Maintenance ond Fuelinl'l
Hazardous Substance Use /Storooe
Oewoterina
Site Access Across Dirt
Other Wstl:
Instructions: 1. Check the box to the left of oil opplicoble construction activity (first column) expected lo occur during construction.
2. Located along the top of the BMP Tobie is o list of BMP's with it's corresponding California Stormwoter Quality Association (CASOA) designation number. Choose one
or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column.
3. Refer lo the CASQA construction handbook for information ond deto,s of the chosen BMPs ond how to apply them to the project.
SHOW THE LOCATIONS OF ALL CHOSEN BMPs ABOVE
ON THE PROJECTS SITE PLAN/EROSION CONTROL PLAN.
SEE THE REVERSE SIDE OF THIS SHEET FOR A SAMPLE
EROSION CONTROL PLAN.
PROJECT INFORMATION
Site Address: '2,og'J W~:oo~ De
Assessor's Parcel Number: ________ _
Emergency Contact:
Nome· ~ ~ 6,(a X: !") \:o
NC 0 0 :J: :::E
"' I i
\ I D 24 Hour Phone: 7£pQ W7 '2.. 637~
RE
\J 2 1 ?.O'l.'3 NO ~ge 1 of 1
c\TY o-
B J'' 0. .J
.o
Construction Threat to Storm Water Quality
(Check Box)
0 t.4E01Ut.t j,14ow
CC oo (.)::,S
00 I i
r,_..
'
REV 02/16