HomeMy WebLinkAbout2269 MASTERS RD; ; CBR2022-0255; PermitBuilding Permit Finaled
Residential Permit
Print Date: 03/12/2025
Job Address:
Permit Type:
Parcel#:
Valuation:
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load :
Code Edition:
Sprinkled:
Project Title:
2269 MASTERS RD, CARLSBAD, CA 92008-3849
BLDG-Residential
2121401000
$62,000.00
Work Class:
Track#:
Lot#:
Project#:
Plan#:
Construction Type:
Orig. Plan Check #:
Plan Check#:
Alteration
Permit No:
Status:
{city of
Carlsbad
CBR2022-0255
Closed -Finaled
Applied: 01/26/2022
Issued: 06/23/2022
Finaled Close Out: 03/12/2025
Final Inspection: 11/19/2024
INSPECTOR: Kersch, Tim
Dreibelbis, Peter
Renfro, Chris
Alvarado, Tony
Description: INTERIOR REMODEL KITCHEN/LIVING AREA (1200 SF)/BI-FOLD DOOR/DECK (323 SF)/PERGOLA (323 SF)
Applicant: Property Owner:
DTV DESIGNS
TOM VORKOPER
7406 SE 36TH ST
CO-OWNERS AARON AND LAURA SHIRLEY
2269 MASTERS RD
MERCER ISLAND, WA 98040-3413
(858) 775-3465
FEE
BUILDING PLAN CHECK
BUILDING PLAN CHECK FEE (manual)
CARLSBAD, CA 92008-3849
BUILDING PLAN REVIEW-MINOR PROJECTS (PLN)
DECKS/BALCONY-NEW/REPLACE
REMODEL-RESIDENTIAL-OTHER
SB1473 -GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION -RESIDENTIAL (SMIP)
Total Fees : $2,721.58 Total Payments To Date: $2,721.58
Contractor:
PROPACIFIC BUILDERS INC
3146 TIGER RUN CT, # 109
CARLSBAD, CA 92010-6503
(760) 481-8003
Balance Due:
AMOUNT
$1,003.60
$64.92
$98.00
$825.00
$719.00
$3.00
$8.06
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired .
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
( City of
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
Plan Check C~zz.-ozs-5"
Est. Value ~
Job Address 2269 Masters Rd Unit: APN: 212-140-10-00 -----
CT/ProJ·ect #: Lot#: Vear Built: 1997 --------------------------------
BRIEF DESCRIPTION OF WORI<: Interior remodel including new bi-fold door, new kitchen and living room. A pergola and 2nd floor deck are also proposed.
E] New SF : Living SF, ____ Deck SF, 323 Patio SF, ~ a rage SF __ _
Is this to create an Accessory Dwelling Unit? O Y o N New Fireplace? O YON, if yes how many? ___ _
GJ Remodel:_1_2_oo ____ SF of affected area Is the area a conversion or change of use? O Y 0) N
□ Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _
0Solar: ___ KW, ___ Modules, Mounted:ORoofOGround, Tilt: 0 Y0 N, RMA:CY O N,
Battery:OYO N, Panel Upgrade: Cv ON
Other:
PRIMARY APPLICANT
Name: Tom Vorkoper
PROPERTY OWNER
Name: Laura Shirley
Address: 7406 SE 36th St
City: Mercer Island
Phone: 858.775.3465
State:_w_a __ Zip:98040
Ema ii: tvorkoper@dtv-designs.com
DESIGN PROFESSIONAL
Name: same as PRIMARY APPLICANT
Address: _________________ _
City: ________ S,tate: ___ Zip: ____ _
Phone: _________________ _
Email: _________________ _
Architect State License: C 28199 ------------
Address: 2269 Masters Rd
City: Carlsbad State:_c_a_ .... Zip: 92008
Phone:, ____________________ _
Email: ____________________ _
CONTRACTOR OF RECORD
Business Name: ProPacific Builders
Address: 5631 Palmer Way Ste D
City: Carlsbad
Phone: 760.481.8003
State:_c_a __ Z.ip:92010
Email: mike@propacificbuilders.com
CSLB License #: 897986 Class: B --------
Carlsbad Business License# (Required):_1_74_2_5_8 _____ _
APPLICANT CERT/FICA TION: I certify that I have read the app/icarion and state that the above infar n is correct and that the Information of the plans Is accurate. I
agree to comply with all City ordinances and State lows relating to building construction.
163S Faraday Ave Carlsbad, CA 92008 Ph: 760-602·271 Email: Bulldlng@carlsbadca.gov
REV. 10121
THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _
A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWN ER. IF THE PERSON SIGNING
THIS FORM IS AN AGENT FOR EITHER ENTfTY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRlOR TO PERMIT ISSUANCE.
(OPTION A): LICENSED CONTRACTOR DECLARATION:
I herebyaffirm under penal tyof pe1jury that I am licensed under provisions of Chapter 9(commencingwi th Section 7000)of Division 3
of the Business and Professions Code, and my license is·in fu/ I force and effect. I also affirm tinder penal tyof perj ury one of the
following declarations (CHOOSE ONE):
01 have and will maintain a certificate of consent to self-insure for workers' compensatlon provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued. PolicyNo. _________________________________________ _
-OR-
(!] I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit Is issued.
My workers' compensation insurance carrier and policy number are: lnsuranceCompany Name: SiititJSFiAmaa:bTStl race Co
Policy No. WOOffi23 Expiration Date: ..,'SY,,...' C,.,.ffi.,,...tl.,.,3----------•
-OR-
O Certificate of Exemption: I certify that in the performance of the work for which this permit is Issued, I shall not employ any person In any manner so asto become
subject to the workers' compensation laws of California. WARNING : Failure to secure workers compensation coverage is unlawful and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for In Section 3706 of the labor Code,
interest and attorney's fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby atnrm that there is a construction lending agency for the performance of the work this permit Is issued (Sec. 3097 (i) Civil Code).
Lender's Name: ______________________ Lender's Address: _____________________ _
CONTRACTOR C£RT/FICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and
utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potenUally existing detail within these plans Inconsistent with the site plan are
not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show
the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed
use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation.
All Improvements existing on the property were completed In accordance with all regulations in existence at the time of their construction, unless otherwise noted.
NAME (PRINT): Scott Jaeger SIGNATURE: AAriM---DATE:_""""6_-2_1_-2_2 __
Note: If the person signing above is an authorized agent fot the contra . ,iz, r of authorfzatlon on contractor letterhead.
(t<'f
-OR-"
(OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not Intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who bullds or improves thereon, and who does such
work himself or through his own employees, provided that such Improvements are not Intended or offered for sale. If, however, the building or Improvement Is sold
within one year of completion, the owner-builder will have the burden of proving that he did not build or Improve for the purpose of sale).
-OR-
□ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's license Law).
-OR-O I am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
AND,
D FORM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit Issued to a property owner.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if It has not been constructed ln Its entirety by licensed
contractors. I understand that a copy of the applicable /aw, Section 7044 of the Bus;ness and Professions Code, isovai/able upon request when this application is
submitted orat the following Web site: http: I /www.leginfo.co.gov/colaw.html.
OWNER CERTIFICATION: The appllcant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utllltles/utillty
easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans Inconsistent with the site plan are not approved
for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct
dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each
building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All
improvements existing on the property were completed In accordance with all regulations in existence at the time of their construction, unless otherwise noted.
NAME (PRINT): SIGN: __________ DATE: _____ _
Note: If the erson si nln above is an authorized a ent for the ro ert owner intlud.e form 8-62 si ned b ro ert owner.
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558
2
Email: Buildlng@carlsbadca.gov
REV.10/2
PERMIT INSPECTION HISTORY for (CBR2022-0255)
Permit Type: BLDG-Residential Application Date: 01/26/2022 Owner: CO-OWNERS AARON AND LAURA
Work Class: Alteration
Status: Closed -Finaled
SHIRLEY
Issue Date: 06/23/2022 Subdivision: CARLSBAD TCT#91-03
Expiration Date: 12/06/2024
IVR Number: 38355
Address: 2269 MASTERS RD
CARLSBAD, CA 92008-3849
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector Reinspection Inspection
Wednesday, March 12, 2025
Checklist Item
Are erosion control BMPs
functioning properly?
Are perimeter control BMPs
maintained?
Is the entrance stabilized to
prevent tracking?
Have sediments been tracked
on to the street?
Has trash/debris accumulated
throughout the site?
Are portable restrooms
properly positioned?
Do portable restrooms have
secondary containment?
Status
COMMENTS Passed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Page 3 of3
PERMIT INSPECTION HISTORY for (CBR2022-0255)
Permit Type: BLDG-Residential Application Date: 01/26/2022 Owner: CO-OWNERS AARON AND LAURA
SHIRLEY
Work Class: Alteration Issue Date: 06/23/2022 Subdivision: CARLSBAD TCT#91-03
Address: 2269 MASTERS RD
CARLSBAD, CA 92008-3849
Status:
Scheduled
Date
10/12/2022
10/13/2022
12/29/2022
06/10/2024
11/19/2024
Closed -Finaled
Actual Inspection Type
Start Date
10/12/2022 BLDG-Final Inspection
Checklist Item
Expiration Date: 12/06/2024
IVR Number: 38355
Inspection No.
193928-2022
COMMENTS
Inspection
Status
Cancelled
Primary Inspector
Tony Alvarado
BLDG-Building Deficiency Canceled
10/13/2022 BLDG-17 Interior
Lath/Drywall
Checklist Item
194040-2022
COMMENTS
Passed Tim Kersch
BLDG-Building Deficiency
12/29/2022 BLDG-Final Inspection
Checklist Item
BLDG-Plumbing Final
BLDG-Structural Final
BLDG-Electrical Final
06/06/2024 BLDG-71 Set Ups
Checklist Item
199835-2022
COMMENTS
Partial Pass Tony Alvarado
December 29, 2022: partial pass.
1. Partial second story balcony, would
walking deck, and attached open lattice
trellis, per engineered plans and detail
specifications -partial pass.
2. PENDING:
a) anchoring/method of attachment, two
new 6 x 8 trellis beam lattice members,
connection to new 8 x 12 attached patio
structure beam not completed/not
connected-substandard construction
anchored connections.
b) contractor only has only (3) 8D penny
nailing/toenails (typical), at one side of
each trellis 6" x 8" beams (not acceptable).
3. Informed contractor representative that
approved lag bolts with photos confirming
new lag bolt anchoring connection system
will be acceptable.
4. The rest of second level, wood walking
deck, balcony, and attached open lattice
beam trellis work-OK.
250983-2024
COMMENTS
Partial Pass Tony Alvarado
BLDG-Building Deficiency Partial Pass
11/19/2024 BLDG-Final Inspection
Checklist Item
268555-2024
COMMENTS
BLDG-Building Deficiency
BLDG-Structural Final
BLDG-Electrical Final
BLDG-SW-Inspection 268557-2024
Passed Tony Alvarado
Passed Tony Alvarado
Wednesday, March 12, 2025
Reinspection Inspection
Reinspectlon Incomplete
Passed
No
Complete
Passed
Yes
Re inspection Incomplete
Passed
Yes
Yes
Yes
Reinspectlon Incomplete
Passed
Yes
Passed
Yes
Yes
Yes
Complete
Complete
Page 2 of 3
Building Permit Inspection History Finaled
(cityof
Carlsbad
PERMIT INSPECTION HISTORY for (CBR2022-0255)
Permit Type: BLOG-Residential Application Date: 01/26/2022 Owner: CO-OWNERS AARON AND LAURA
SHIRLEY
Work Class: Alteration Issue Date: 06/23/2022 Subdivision: CARLSBAD TCT#91-03
Status: Closed -Finaled Expiration Date: 12/06/2024
IVR Number: 38355
Address: 2269 MASTERS RD
CARLSBAD, CA 92008-3849
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector
Date Start Date Status
08/01/2022 08/01/2022 BLDG-21 188118-2022 Passed Chris Renfro
Underground/Underflo
or Plumbing
Checklist Item COMMENTS
BLDG-Building Deficiency
09/02/2022 09/02/2022 BLDG-11 190451-2022 Passed Peter Dreibelbis
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS
BLDG-Building Deficiency
09/16/2022 09/16/2022 BLDG-11 191871-2022 Partial Pass Peter Dreibelbis
Foundation/Ftg/Piers
(Rebar)
Checklist Item
BLDG-Building Deficiency
COMMENTS
Dry pack ok, ok to pour
09/29/2022 09/29/2022 BLDG-14 192923-2022 Partial Pass Chris Renfro
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item
BLDG-Bui lding Deficiency
COMMENTS
2nd story deck nailing ok. Shear ok. Wrap
and install windows and make watertight
and call for rough combo inspection
10/11/2022 10/11/2022 BLDG-18 Exterior 193694-2022 Passed Tim Kersch
Wednesday, March 12, 2025
Lath/Drywall
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-84 Rough
Combo(14,24,34,44)
193695-2022
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(D ecks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
COMMENTS
Passed Tim Kersch
Reinspection Inspection
Complete
Passed
Yes
Complete
Passed
No
Relnspectlon Incomplete
Passed
No
Reinspection Incomplete
Passed
Yes
Passed
Yes
Passed
Yes
Yes
Yes
Yes
Yes
Complete
Complete
Page 1 of 3
Carlsbad CB-CBR2022-0255
February 11, 2022
~ ~,. /
~ CITY OF
. · • @elop,nent Services
SPECIAL INSPECTLON \) ~ uilding Division
AGREEMENf ~ 16~5 Faraday Avenue
CARLSBAD 8-45 ~ • \ , 760-602-2719
www.carlsbadca.gov
In accordance with Chapter 17 of the California Building Code the following m st be completed when work being performed
requires special inspection, structural observation and constn.1ction material testing.
'roject/Permit: Shirley Remodel Project Address: 2269 Masters Rd
A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check~ you are Owner-Builder
□. (If you checked as owner-builder you must also complete Section B of this agreement.)
Name: (Please print,_) __ D_a_le ___________ T __________ V_o_r_k_o..,.p_e_r ____ _
(First) (M il
Mailing Address 7406 SE 36th St, Mercer Island, Wa 98040
Email· tvorkoper@dtv-designs.com
(l851)
Phone· 858.775.3465
I am: □Property Owner □Property Owner's Agent of Record CllArchitect of Record □Engineer of Record
State of California Registration NumbeL· ____________ Expiration Date:_4_/_2_0_2_3 ____ _
AGREEMENT: I, the undersigned, decl under penalty of perjury under the laws of the State of California, that I have read
understand, acknowledge and pr comply with the City of Carlsbad requirements for special inspections, structura
observations, construction mater" s n • abrication of building components, as prescribed in the statement o
special inspections noted on th plans and, as required by the California Building Code.
Signatur Date: April 25, 2022
B. CONTRACTOR'S STATEMENT RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the
contractor I builder/ owner-builder.
contractor's company Name: ProPacific Builders, Inc. Please check if you are Owner-Builder D
Name: (Please prinl) ___ S_c_o_t_t __________________ _._Ja_e_g,,__e_r _______ _
(Firtt) (Ml) (Le,o
Mailing Address : 5631 Palmer Way Ste D, Carlsbad, Ca. 920 l 0
Email: scott@propacificbuilders.com Phone_· _7_6_0_.4_8_1_.8_0_0_3 ___ _
State of California Contractor's License Number_· 8_9_7_9_8_6 ______ Expiration Date: 3 .31/2023
• I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on
the approved plans;
• I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the
building official;
• I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and
frequency of reporting and the distribution of the reports; and
• I certify that I will have a qualified person within our (the contractor's) organization to exercise such control.
• I will ovide a fin I re ort I ett in com liance with CBC Section 1704.1.2 rior tor uestin final
Signature·~--Date: April 25, 2022 ------
S.45 Page 1 of 1 Rev. 0S/11
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF1 R-AL T-05-E (Revised 01/1 9)
COMMISSION
CERTIFICATE OF COMPLIANCE
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
Project Name: Shirley Remodel
CALIFORNIA ENERGY
CFlR-ALT-05-E
(Page 1 of 8)
Page l of 8 I Date Prepared· 01 /06/2022
This compliance document is only applicable to simple alterations that do not require HERS verification far compliance. When HERS verification is required, a CFlR-ALT-01 shall first be registered
with a HERS Provider Data Registry.
Alterations to Space Conditioning Systems that are exempt from HERS verification requirements may use the CFlR-AL T-05 and CF2R-AL T-05 Compliance Documents. Possible exemptions from
duct leakage testing include: less than 40 ft of ducts were added or replaced; or the existing duct system was insulated with asbestos; ar the existing duct system was previously tested and passed
by a HERS Rater. If space conditioning systems are altered and ore not exempt from HERS verification, then a CFlR-AL T-02 must be completed and registered with a HERS Provider Data Registry.
Alterations that utilize close Cell Spray Polyurethane Foam (ccSPF) with a density of 1.5 to less than 2.5 pounds per cubic foot having an R-value greater than 5.8 per inch, or Open Cell Spray
Polyurethane Foam (ocSPF} with o density of 0.4 to less than 1.5 pounds per cubicfaat having on R-volue of 3.6 per inch, shall complete and register o CFlR-ALT-01 with o HERS Provider Data
Registry.
If more than one person hos responsibility for installation of the items an this certificate, each person shall prepare and sign o certificate opplicoble to the portion of construction for which they
ore responsible. Alternatively, the person with chief responsibility for construction shall prepare and sign this certificate for the entire construction. All applicable Mandatory Measures shall be
met. Temporary labels shall not be removed before verification by the building inspector.
A. General Information
01 Project Name: Shirley Remodel
03 Project Location: 2269 Masters Rd
05 CA City: Carlsbad
07 Zip Code: 92008
09 Climate Zone: 7
11 Building Type: Single Family
13 Project Scope: Alteration
CA Building Energy Efficiency Standards -2019 Residential Compliance
02
04
06
08
10
12
Date Prepared:
Building Front Orientation (deg or cardinal):
Number of Altered Dwelling Units:
Fuel Type:
Total Conditioned Floor Area (ft2):
Slab Area (ft2):
CBR2022-0255
2269 MASTERS RD
01/06/2022
NW
1
Natural Gas
3,018
1,601
INTERIOR REMODEL KITCHEN/LIVING AREA (1200
SF)/B1-FOLD DOOR/DECK (323 SF)/PERGOLA (323 SF)
2121401000
1/26/2022
CBR2022-0255
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF 1 R-AL T-05-E (Revised 01/1 9)
COMMISSION
CERTIFICATE OF COMPLIANCE
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
Project Name; Shirley Remodel
B. Building Insulation Details (Section 150.2(b)1)
01 02 03 04 05 06
Frame Frame
Frame Depth Spacing Cavity
Tag/ID Assembly Type Type (inches) (inches) R-value
CA Building Energy Efficiency Standards -2019 Residential Compliance
07 08 I 09
Proposed
Appendix JA4
Continuous Reference
Insulation
R-value U-factor Table Cell
CALIFORNIA ENERGY
CFlR-ALT-05-E
(Page 2 of 8)
Page 2 of 8 I Date Prepared 01/06/22
10 11
Required
U-Factor
from Table
150.1-A or
B Comments
January 2019
STATE OF CALIFORNIA
Prescriptive Res idential Alterations That Do Not Require HERS Field Verification
CEC-CF1 R-ALT-05-E (Revised 01 /19)
COMMISSION
CERTIFICATE OF COMPLIANCE
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CALIFORNIA ENERGY
CFlR-ALT-05-E
(Page 3 of 8)
Project Name: Shirley Remodel Page 3 of 8 I Date PreP3red. 01/06/22
C. Roof Replacement (Prescri ptive Alteration, Section 150.2(b)1H)
01 02 03 04 05 06 07 08 09 10 11 12 13
Proposed M inimum Required
R-value Aged Solar Thermal SRI Aged Solar Thermal
Method of Roof CRRC Product ID Deck Initial Solar Reflectanc Emittanc (Optional Reflectanc Emittanc SRI
Compliance Pitch Exception Number Product Type Insulation Reflectance e e ) e e (Optional)
NOTES:
• Roof area covered by building integrated photovoltaic panels and sol ar thermal panels are exempt from the above Cool Roof requirements .
• Liquid field applied coatings must comply with installation criteria from Section 110.8(i)4 .
D. Fenestration/Glazing Allowed Areas and Efficiencies (Section 150 .2(b)l )
01 02 03 04 05 06 07
Maximum Maximum
Allowed Allowed West-Existing Existing
Fenestration Facing Fenestration West-Facing Maximum Maximum Maximum Maximum
Area For All Fenestration Area for All Fenestration Allowed Allowed Allowed Allowed
Alteration Orientations Area Only Orientations Area U-factor U-factor SHGC SHGC
Type (ft1) (ft1) (ft1) (ft1) (Windows) (Skylights) (Windows) (Skylights) Comments
Add n/a n/a 190 0 0.32 0.55 0.25 0.3
CA Building Energy Efficiency Standards -2019 Residential Compliance January 2019
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF1R-ALT-05-E (Revised 01/19)
COMMISSION
CERTIFICATE OF COMPLIANCE
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CALIFORNIA ENERGY
CFlR-ALT-05-E
(Page 4 of 8)
Project Name: Shirley Remodel Page 4 of 8 I Date Prepared; 01/06/22
E. Fenestration Proposed Areas and Efficiencies -Add (Section 150.2(b)1A)
Note: Doors w ith greater than or equal to 25 percent glazed area are considered glazed doors and are treated as fenestration products.
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Orientatio Proposed Proposed West Proposed Proposed Exterior Combined
Tag/ID Fenestration Frame Dynamic Number of Fenestration Facing Proposed U-factor Proposed SHGC Shading SHGC from n Type Type Glazing N,S, W, E Panes Area ft2 Fenestration U-factor Source SHGC Source Device CFlR-ENV-03 Area ft2
1 New Metal SE 2 190 0 0.32 NFRC 0.25 NFRC n/a 0.25
15 Total Proposed Fenestration Area 190
16 Maximum Allowed Fenestration Area n/a
17 Compliance Statement I Existing+ Proposed Fenestration Area :S Maximum Allowed Fenestration Area [[] Yes D No
18 Total Proposed West-Facing Fenestration Area 0
19 Maximum Allowed West-Facing Fenestration Area n/a
20 Compliance Statement I Existing+ Proposed West-Facing Fenestration Area :S Maxi,mum Allowed West-Facing Fenestration Area ~ Yes □No
21 Proposed Fenestration U-factor (Windows) 0.32
22 Required Fenestration U-factor (Windows) 0.32
23 Compliance Statement I Proposed Fenestration U-factor :S Required Fenestration U-factor Dll Yes D No
24 Proposed Fenestration SHGC (Windows) 0.25
25 Requ ired Fenestration SHGC (Windows) 0.25
26 Compliance Statement I Proposed Fenestration SHGC :S Required Fenestration SHGC ~ Yes D No
27 Proposed Fenestration U-factor (Skylights) 0
28 Required Fenestration U-factor (Skylights) n/a
29 Compliance Statement I Proposed Fenestration U-factor :S Required Fenestration U-factor @Yes □No
30 Proposed Fenestration SHGC (Skylights) n/a
31 Required Fenestration SHGC (Skylights) n/a
CA Building Energy Efficiency Standards -2019 Residential Compliance January 2019
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF1 R-AL T-05-E (Revised 01/19)
COMMISSION
CERTIFICATE OF COMPLIANCE
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
Project Name: Shirley Remodel
32 I Compliance Statement I Proposed Fenestration SHGC s Required Fenestration SHGC
F. Fenestration/Glazing Proposed Areas and Efficiencies -Replace (Section 150.2(b)1B)
CALIFORNIA ENERGY
CFlR-Al T-05-E
(Page 5 of 8)
Page S of 8 I Date Prepared 01/06/22
D Yes D No
Note: Doors with greater than or equal to 25 percent glazed area are considered glazed doors and are treated as fenestration products.
01 02 03 04 05 06 07 08 9 10 11 12 13 14
Area Area Net Proposed Proposed Exterior Combined SHGC
Tag/ Fenestration Frame Dynamic Orientation Removed Added Added Proposed U-factor Proposed SHGC Shading from
ID Type Type Glazing N, 5, W, E (ft2) (ft2) Area (ft2) U-factor Source SHGC Source Device CFlR-ENV-03
15 Net Added West-facing Fenestration Area
16 Is Net Added Fenestration Area s for west-facing fenestration? D Yes
□No
17 Net Added Fenestration Area (all orientations)
18 Is Net Added Fenestration Areas O for all orientations? D Yes
□ No
19 Proposed Fenestration U-factor (Windows)
20 Required Fenestration U-factor (Windows)
21 Is the proposed Fenestration U-factor s the Required Fenestration U-factor? □Yes
D No
22 Proposed Fenestration SHGC {Windows)
23 Required Fenestration SHGC {Windows)
24 Is the Proposed Fenestration SHGC s the Required Fenestration SHGC? D Yes
D No
25 Proposed Fenestration U-factor {Skylights)
26 Required Fenestration U-factor (Skylights)
27 Is the proposed Fenestration U-factor s the Required Fenestration U-factor? □Yes
D No
28 Proposed Fenestration SHGC
29 Required Fenestration SHGC
30 Is the Proposed Fenestration SHGC s the Required Fenestration SHGC? □Yes
D No
CA Building Energy Efficiency Standards -2019 Residential Compliance January 2019
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF1 R-AL T-05-E (Revised 01/19)
COMMISSION
CERTIFICATE OF COMPLIANCE
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CALIFORNIA ENERGY
CFlR-ALT-05-E
(Page 6 of 8)
Project Name: Shirley Remodel Page 6 of 8 I Date Prepared 01/06/22
G. Space Conditioning (SC) Systems -Heating/Cooling (Prescriptive Section 150.2(b))
Alterations to Space Conditioning Systems shall be exempt from HERS verification requirements as prerequisite for use of the CFlR-AL T-0S and CF2R-ALT-OS Compliance Documents. If new
space conditioning systems are installed or existing systems are altered and are not exempt from HERS verification, then a CFlR-ALT-02 shall be completed and registered with a HERS Provider
Data Registry. In each row below for each dwelling unit in the building, check the box that indicates the exemption from HERS verification compliance:
D a: space conditioning system was not altered;
D b: less than 40 ft of ducts were added or replaced;
D c: (exempt from duct leakage testing) if: the existing duct system was insulated with asbestos;
D d: (exempt from duct leakage testing) if: the existing duct system was previously tested and passed by a HERS Rater.
01 02 03 04
Dwelling Unit Name SC System Identification or Name SC System Location or Area Served Exemption from HERS Verification
(E)FAU (E)FAU 3,018 !XI a tiO b De Od
□a D b De Od
□a Db D e Od
□a Db De Od
O a Ob D e Od
□a Ob De Dd
Oa Ob D e Od
□a Ob De Od
□a Db D e Od
CA Building Energy Efficiency Standards -2019 Residential Compliance January 2019
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF1 R-ALT-05-E (Revised 01/19)
COMMISSION
CERTIFICATE OF COMPLIANCE
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
Project Name: Shirley Remodel
H. Water Heating Systems (Section 150.2(b)1G)
01 02 03 04 05 06
Water
Water Heating # of Water Heating Heating Water System Water
Dwelling Unit Identification or System Location System Heater Heaters
Name Name or Area Served Type Type in System
CA Building Energy Efficiency Standards -2019 Residential Compliance
07 08 09
Water
Heater
Storage Rated
Volume Input
(gal) Fuel Type Type
CALIFORNIA ENERGY
CFlR-ALT-05-E
(Page 7 of 8)
Page 7 of 8 I Oatl! Prepared: 01/06/22
10 11 12 13 14 15
Back-Up
Rated Heating Heating Standby Exterior Solar
Input Efficiency Efficiency Loss Insulation Savings
Value Type Value (%) R-Value Fraction
January 2019
sr,:r;: '.,F c,:..t , :,,.;NIA
Presc·r·iptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF1R-ALT-05-E (Revised 01/19)
COMMISSION
CERTIFICATE OF COMPLIANCE
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
Project Name: Shirley Remodel
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Tom Q. Le
Company·
BTA Engineers, Inc.
Address: 9845 Erma Rd, Suite-204
City/State/Zip: San Diego, CA 92131
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
CALIFORNIA ENERGY
P.age 8 or 8 I O;ate Prepued 01/06/22
./' --../ /-
Documentation Author s,gnal!l<~.P.' /fj'-/ -~-IJIY''
Signature Date: 01/00/22
CEA/ HERS Certification Identification (if applicable)·
M32857
Phone: 858-715-6601
CFlR-ALT-05-E
(Page 8 of 8)
2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible
designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of
Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations .
4. . The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance
documents, worksheets, calculations, plans and specifications submitted to the enforcemtrnt agency for approval with this building permit application.
5. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement
agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included wit.JI documentation the builder provides to the
building owner at occupancy. ,I _
Responsible Designer Name: Responsible Designer Signature: ---1 'T Tom Vorkoper
Company : Date Signed: I I DTV Designs 1/21/22
Address: license: 28199 7406 SE 36 st
City/State/Zip: Phone: 858-77 5-3465 Marcer Island, WA 98040
For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300.
CA Building Energy Efficiency Standards -2019 Residential Complia nce January 2019
DATE: May 12, 2022
JURISDICTION : Carlsbad
• lW
INTERWEST
□ APPLICANT
□ JURIS.
PLAN CHECK#.: CB-CBR2022-0255.rcl, Approved ____ SET: II
PROJECT ADDRESS: 2269 Masters Rd
PROJECT NAME: Remodel to Shirley Residence
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The check list transmitted herewith is for the applicant's information . The plans are being held at
lnterwest until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to the jurisdiction at:
~ lnterwest staff did not advise the applicant that the plan check has been completed.
D lnterwest staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted:
Mail Telephone
0 REMARKS:
By: Abe Doliente
lnterwest
Telephone#:
(by: ) Email :
Fax In Person
Enclosures:
5/5/22
9320 Chesapeake Dri ve, Suite 208 ♦ San Diego, Californ ia 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1 576
Carlsbad CB-CBR2022-0255.rcl, Approved
May 12, 2022
&,
~ ·~
W CITY OF
CARLSBAD
SPECIAL INSPECTION
AGREEMENT
B-45
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
In accordance with Chapter 17 of the California Bulldlng Code the tollowlng must be completed when work being performed
requ ires special Inspection, structural observatlon and construction matertal testing.
'roject/Permit: -----------Project Address_· ______________ _
A. 'THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check If you are Owner-Builder
□. (If you checked as owner-builder you must also complete Section B of this agreement.)
Name: (Please plint ________________________________ _
!Flr~t) (M I J (l.oot)
Mailing Addres_·~---------------------------------
Email_· ________________________ Phone_· _________ _
I am: □Property Owner □Property Owner's Agent of Record □Architect of Record Engineer of Record
state of California Registration Numbe._· ____________ Expiration Date: _______ _
AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the state of California, that I have read,
understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural
observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of
special Inspections noted on the approved plans and, as required by the California Building Code.
Signatur ..... · ______________________ Date: ___________ _
8. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the
contractor I builder / owner-bullder.
Contractor's Company Name: __________________ Please check If you are Owner-Builder □
Name: (Please print) _________________________________ _
(firltl (J,11.)
Mailing Address: _________________________________ _
Email: ________________________ Phone· ___________ _
state of California Contractor's, License Number' __________ Expiration Date; _______ _
• I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on
the approved plans;
• I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the
building official ;
• I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and
frequency of reporting and the distribution of the reports; and
• I certify that I will have a qualified pe,rson within our (the contractor's) organization to exercise such control.
• I wlll provide a final report I letter In compliance with CBC Section 1704.1.2 prior to requesting final
Inspection.
Signature~· ______________________ Date: __________ _
B-45 Page 1 of 1 Rev. 08/11
• fflT
I NTERWES
A SAFEbulll COMPANY
DATE: February 11, 2022
JURISDICTION: Carlsbad
PLAN CHECK#.: CB-CBR2022-0255
PROJECT ADDRESS: 2269 Masters Rd
SET: I
PROJECT NAME: Remodel to Shirley Residence
□ APPLICANT
□ JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
~ The check list transmitted herewith is for the applicant's information. The plans are being held at
lnterwest until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person .
~ The applicant's copy of the check list has been sent to the jurisdiction at:
Tom Vorkoper
D lnterwest staff did not advise the applicant that the plan check has been completed.
~ lnterwest staff did advise the applicant that the plan check has been completed.
Person contacted: Tom Verkoper Telephone#: 858-775-3465
Date contacted:
Mail Telephone
0 REMARKS:
By: Abe Doliente
lnterwest
(by: Email: tvorkoper@dv-designs.com
Fax In Person
Enclosures:
1/31/22
9320 Chesapeake Drive, Sui te 208 ♦ San Diego, Ca lifo rni a 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad CB-CBR2022-0255
February 11, 2022
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: CB-CBR2022-0255
PROJECT ADDRESS : 2269 Masters Rd
JURISDICTION: Carlsbad
FLOOR AREA: Remodel -1200 SF STORIES: 2
Deck -323 SF; Pergola (Patio) -323 SF
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: February 11, 2022
FOREWORD (PLEASE READ):
HEIGHT:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 1/31/22
PLAN REVIEWER: Abe Doliente
This plan review is limited to the technical requirements contained in the California Residential
Code , California Building Code, California Plumbing Code, California Mechanical Code,
California I Electrical Code and state laws regulating energy conservation, noise attenuation and
access for the disabled. This plan review is based on regulations enforced by the Building
Department. You may have other corrections based on laws and ordinance by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Present California law mandates that construction comply with the 2019 edition of the California
Code of Regulations (Title 24), which adopts the following model codes : 2019 CRC , 2019 CBC ,
2019 CPC , 2019 CMC and 2019 CEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification , modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2019 California Building Code, the approval of the plans does not permit the violation of any
state , county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad CB-CBR2022-0255
February 11, 2022
PLANS
Please make all corrections, as requested in the correction list. Submit THREE sets of
plans for residential projects. For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-
2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering
and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City
Planning , Engineering and Fire Departments until review by lnterwest is complete .
1. Provide item-by-item responses on an 8-1/2-inch by 11 -inch sheet(s) clearly and
specifically indicating where and how each correction item has been addressed
(vague responses, such as "Done" or "See plans," are unacceptable)
2. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code). Signatures on the final
sets of plans will be verified before they are approved.
3. Plans shall have the structural portions signed and sealed by the California state
licensed engineer or architect responsible for their preparation, along with
structural calculations. (California Business and Professions Code). Signatures
on the final sets of plans will be verified before they are approved.
FIRE PROTECTION
4. Revise the location of the smoke alarm so that it is at least 20 ft away from the
cooking appliance.
RAILINGS
5. Guards (Section R312):
a) Shall be provided for those portions of open-sided walking surfaces that are
located more than 30" above the floor or grade below.
b) Shall have a height of 42" (may be 34" along the sides of stairs).
c) Openings between railings shall be less than 4". The triangular openings formed
by the riser, tread and bottom element of a guardrail at a stair shall be less than 6".
d) Shall be detailed to show capability to resist a concentrated load of 200 pounds
in any direction along the top rail and 50 psf for infill components. Calculations may be
required. Table R301 .5.
DECKS/BALCONIES
Carlsbad CB-CBR2022-0255
February 11, 2022
6. Enclosed framing in wood exterior decks shall be provided with openings that
provide a net free cross ventilation area not less than 1 /150 of the area of each
separate space. Section R317.1 .6
7. Wood decks that support moisture-permeable floors shall be provided with an
impervious moisture barrier system under the moisture-permeable floor, with
positive drainage. Section R317 .1.
8. Where decks or other elevated walking surfaces are exposed to water from direct
or blowing rain , snow or irrigation , and the structural framing is protected by an
impervious moisture barrier, the construction documents shall include details for
all elements of the impervious moisture barrier system , The construction
documents shall include the manufacturer's installation instructions. Section
R106.1.5
9. Show the sizes/locations of deck drains and overflows. Section R903.4 .
STRUCTURAL
10. Decks shall be designed for 60 psf live load. Table R301.5.
11 . Recheck the deck joists and beams (FB-4) using 60 PSF for the live load.
12. The plans indicate that special inspection will be provided. Please complete the
attached City Special Inspection form .
MISCELLANEOUS
13. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes □ No □
14. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake
Drive , Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Error! Reference
source not found. at lnterwest. Thank you.
Carlsbad CB-CBR2022-0255
February 11, 2022
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Abe Doliente
BUILDING ADDRESS: 2269 Masters Rd
BUILDING OCCUPANCY: R3/u
BUILDING AREA
PORTION ( Sq. Ft.)
Remodel 1200
Deck 323
Pergola (Patioi) 323
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb
j 1997 UBC Building Permit Fee 3
I r,I t>-1:
I 1997 UBC Plan Check Fee 3
Valuation
Multiplier
By Ordinance
Type of Review: ,v" Complete Review
,,
r Repetitive Fee 3 Repeats
Comments:
,,
r Other
r Hourly
EsGil Fee ,,
PLAN CHECK#.: CB-CBR2022-0255
DATE: February 11, 2022
Reg. VALUE ($)
Mod.
7
$1,644.ooJ
r Structural Only
$1,068.60
Sheet 1 of 1
D T V v
'DESIGNS \
April 25, 2022
City of Carlsbad
Interwest Comments Responses
Shirly Remodel CB -CBR2022-0255
Comment responses for project: APN 212-140-10-00
Item
2
3
4
Sa Sb
Sc
Sd
6.
7.
8.
9.
10.
11.
12.
13.
Response
All pages have been stamped / signed by architect.
Structural sheets and calcs have been stamped and signed.
Smoke and Carbon Monoxide detector in Dining Rm has been moved closer to the
hall and farther from the cooking appliance. See I/ A 2.01 and I/ E 2.01.
Guardrail+ wall shown at 42" on drawings 7 & 16 & 18 / A 3.01 and 2 & 20 / A 3.02.
Openings less than 4" shown on drawing 5 / A 3.02
Clarified guardrail low wall connections. See 5 & 19 / A 3.02.
Added 36 linear feet of metal continuous soffit vent. See I / A 2.02 and 19 / A 3.02.
Composite deck over 2x pres. treated sleepers o/ waterproofing with positive
drainage to outer edge of deck shown on l /A 2.02, 2 & 19 / A 3.02.
Clarified waterproofing details. See 5 & 19 / A 3.02.
Also added manufactured details and application specifications.
There are no deck drains or overflows. The drainage is designed to sheet flow over
outer edge of deck. See 2 / A 2.02 and 19 / A 3.02.
Changed joists to be 12 " o.c. (from 16" o.c.)
See attached new calculations
See attached new calculations. Deck beam is ok.
See attached special inspection form
NO.
No changes have been made to the plans other than the result of these corrections.
If you have any questions or comments, please do not he sit te to contact me.
Sincerely,
Dale (Tom) Vorkoper
858. 775.3465 7406 SE 36th St, Mercer Island, Wa. 98040 tvorkoper@dtv-designs.com
INTERW£ST
DA TE : February 11, 2022
JURISDICTION: Carlsbad
PLAN CHECK#.: CB-CBR2022-0255
PROJECT ADDRESS : 2269 Masters Rd
SET: I
PROJECT NAME: Remodel to Shirley Residence
D APPLICANT
D JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
~ The check list transmitted herewith is for the applicant's information. The plans are being held at
lnterwest until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to the jurisdiction at:
Tom Vorkoper
D lnterwest staff did not advise the applicant that the plan check has been completed.
~ lnterwest staff did advise the applicant that the plan check has been completed.
Person contacted : Tom Verkoper Telephone#: 858-775-3465
Date contacted:
Mail Telephone
0 REMARKS :
By: Abe Doliente
lnterwest
(by: Email : tvorkoper@dv-designs.com
Fax In Person
Enclosures:
1 /31 /22
9320 Chesapeake Drive, Suite 208 ♦ San Diego, Califo rnia 92 123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
,
Carlsbad CB-CBR2022-0255
February 11, 2022
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: CB-CBR2022-0255
PROJECT ADDRESS: 2269 Masters Rd
JURISDICTION: Carlsbad
FLOOR AREA: Remodel -1200 SF STORIES: 2
Deck -323 SF; Pergola (Patio) -323 SF
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION :
DATE INITIAL PLAN REVIEW
COMPLETED: February 11, 2022
FOREWORD (PLEASE READ):
HEIGHT:
DATE PLANS RECEIVED BY
ESGIL CORPORATION : 1/31/22
PLAN REVIEWER : Abe Doliente
This plan review is limited to the technical requirements contained in the California Residential
Code, California Building Code , California Plumbing Code , California Mechanical Code,
California I Electrical Code and state laws regulating energy conservation, noise attenuation and
access for the disabled. This plan review is based on regulations enforced by the Building
Department. You may have other corrections based on laws and ordinance by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Present California law mandates that construction comply with the 2019 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2019 CRC , 2019 CBC ,
2019 CPC, 2019 CMC and 2019 CEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification , modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2019 California Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
I
Carlsbad CB-CBR2022-0255
February 11, 2022
PLANS
Please make all corrections, as requested in the correction list. Submit THREE sets of
plans for residential projects. For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad , CA 92008, (760) 602-
2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering
and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1 468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City
Planning, Engineering and Fire Departments until review by lnterwest is complete.
1. Provide item-by-item responses on an 8-1/2-inch by 11-inch sheet(s) clearly and
specifically indicating where and how each correction item has been addressed
(vague responses, such as "Done" or "See plans," are unacceptable)
2. All sheets of plans must be signed by the person responsible for their
preparation . (California Business and Professions Code). Signatures on the fina l
sets of plans will be verified before they are approved.
3. Plans shall have the structural portions signed and sealed by the California state
licensed engineer or architect responsible for their preparation, along with
structural calculations. (California Business and Professions Code). Signatures
on the final sets of plans will be verified before they are approved .
FIRE PROTECTION
4. Revise the location of the smoke alarm so that it is at least 20 ft away from the
cooking appliance.
RAILINGS
5. Guards (Section R312):
a) Shall be provided for those portions of open-sided walking surfaces that are
located more than 30" above the floor or grade below.
b) Shall have a height of 42" (may be 34" along the sides of stairs).
c) Openings between railings shall be less than 4". The triangular openings formed
by the riser, tread and bottom element of a guardrail at a stair shall be less than 6".
d) Shall be detailed to show capability to resist a concentrated load of 200 pounds
in any direction along the top rail and 50 psf for infill components. Calculations may be
required. Table R301.5.
DECKS/BALCONIES
Carlsbad CB-CBR2022-0255
February 11, 2022
6.
7.
8.
9.
Enclosed framing in wood exterior decks shall be provided with openings that
provide a net free cross ventilation area not less than 1 /150 of the area of each
separate space. Section R317.1.6
Wood decks that support moisture-permeable floors shall be provided with an
impervious moisture barrier system under the moisture-permeable floor, with
positive drainage. Section R317.1.
Where decks or other elevated walking surfaces are exposed to water from direct
or blowing rain , snow or irrigation, and the structural framing is protected by an
impervious moisture barrier, the construction documents shall include details for
all elements of the impervious moisture barrier system , The construction
documents shall include the manufacturer's installation instructions. Section
R106.1.5
Show the sizes/locations of deck drains and overflows. Section R903.4.
STRUCTURAL
10. Decks shall be designed for 60 psf live load. Table R301.5.
11. Recheck the deck joists and beams (FB-4) using 60 PSF for the live load.
12. The plans indicate that special inspection will be provided. Please complete the
attached City Special Inspection form.
MISCELLANEOUS
13. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes □ No □
14. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake
Drive, Suite 208, San Diego , California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Error! Reference
source not found. at lnterwest. Thank you.
,,
Carlsbad CB-CBR2022-0255
February 11, 2022
41~ "",... / ~ CITY OF
CARLSBAD
SPECIAL INSPECTION
AGREEMENT
B-45
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed
requires special inspection, structural observation and construction material testing.
>roject/Permit: __________ _ Project Address· _________________ _
A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder
□. (If you checked as owner-builder you must also complete Section 8 of this agreement.)
Name: (Please print~----------------------------------
!First1 !Mil
Mailing Addres~----
Email_· _________________________ Phone: __________ _
I am : □Property Owner □Property Owner's Agent of Record □Architect of Record □Engineer of Record
State of California Registration Numbe~·-------------Expiration Date: ________ _
AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read,
understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural
observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of
special inspections noted on the approved plans and, as required by the California Building Code.
Signatur~-----------------------Date: ___________ _
B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the
contractor I builder/ owner-builder.
Contractor's Company Name: ___________________ Please check if yoo are Owner-Builder o
Name: (Please print) __________________________________ _
(MI i (Last)
Mailing Address: ___________________________________ _
Email : _________________________ Phone: ___________ _
state of California Contractor's License Number_· __________ Expiration Date: _______ _
• I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on
the approved plans;
• I acknowledge that control wil l be exercised to obtain conformance with the construction documents approved by the
building official;
• I will have in-place procedures fo r exercising contro l within our (the contractor's) organization, for the method and
frequency of reporting and the distribution of the reports; and
• I certify that I will have a qualified person within our (the contractor's) organization to exercise such control.
• I will provide a final report I letter in compliance with CBC Section 1704.1.2 prior to requesting final
inspection.
Signature~: ________________________ Date: ___________ _
B-45 Page 1 of 1 Rev. 08/11
env1s1on
a eh ---% a . . engineering
STRUCTURAL ENGINEERS
565 PEARL ST. SUITE 209
LA JOLLA, CA 92037
858.246. 77 45
ADDENDUM
STRUCTURAL CALCULATIONS
DATE: 04/25/22
PROJECT: SHIRLEY REMODEL
DESIGNER: DTV DESIGNS
ON Lt) ON ■"'-0 0 ._..,
~N A..I o-.. , ~~o ..-I.{')
N I
N N N
0
N
0::
aJ
(.)
a Envision Engineering
La Jolla, CA 92037
Project Title:
Engineer:
Project ID:
Project Descr:
F
I Wood Beam
UC#: KW-06011582, Build 20.22.3.31 Envision Engineering, Inc.
DESCRIPTION: DECK JOISTS WITH 60 PSF
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : IBC 2018
Material Properties
(c) ENERCALC INC 1983-2022
Analysis Method : Allowable Stress Design
Load Combination · IBC 2018
Fb +
Fb -
1000 psi
1000 psi
1500 psi
E : Modulus of Elasticity
Wood Species
Wood Grade
Beam Bracing
Douglas Fir-Larch
No.1
Fe -Prll
Fe -Perp
Fv
Ft
Beam is Fully Braced against lateral-torsional buckling
D 0.016 L 0.06
2x12
Span= 17.0ft
625 psi
180 psi
675 psi
Ebend-xx 1700ksi
Eminbend -xx 620ksi
Density 31.21 pcf
Repetitive Member Stress Increase
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight NOT internally calculated and added
Uniform Load : D = 0.0160, L = 0.060 ksf, Tributary Width = 1.0 ft
DESIGN SUMMARY __ _ __ Design OK
Maximum Bending Stress Ratio = 0.905 1 Maximum Shear Stress Ratio = 0.284 : 1
Section used for this span 2x12 Section used for this span 2x12
fb: Actual = 1,041 .26psi fv: Actual = 51.14psi
Fb: Allowable = 1,150.00psi Fv: Allowable = 180.00 psi
Load Combination +D+L Load Combination +D+L
Location of maximum on span = 8.500ft Location of maximum on span = 0.000 ft
Span # where maximum occurs = Span# 1 Span # where maximum occurs = Span# 1
Maximum Deflection
Max Downward Transient Deflection 0.375 in Ratio= 544 >=360 Span: 1 : L Only
Max Upward Transient Deflection O in Ratio= 0 <360 n/a
Max Downward Total Deflection 0.475 in Ratio= 429>=180 Span: 1 : +D+L
Max Upward Total Deflection O in Ratio= 0<180 n/a
--····----· -····----•-···
Maximum Forces & Stresses for Load Combinations
Load Combination lvlax S!ress Ra!1os lvlomen! 'ilalues Sfiear 'ilalues
Segment Length Span# M V Cd CFN Ci Cr Cm Ct CL M fb F'b V fv F'v
D Only 0.00 0.00 0.00 0.00
Length= 17.0 ft 0.212 0.066 0.90 1.000 1.00 1.15 1.00 1.00 1.00 0.58 219.21 1035.00 0.12 10.77 162.00
+D+L 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length = 17.0 ft 0.905 0.284 1.00 1.000 1.00 1.15 1.00 1.00 1.00 2.75 1,041 .26 1150.00 0.58 51 .14 180.00
+D+0.750L 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length= 17.0 ft 0.581 0.182 1.25 1.000 1.00 1.15 1.00 1.00 1.00 2.20 835.75 1437.50 0.46 41.04 225.00
+0.600 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length= 17.0 ft 1 0.071 0.022 1.60 1.000 1.00 1.15 1.00 1.00 1.00 0.35 131.53 1840.00 0.07 6.46 288.00
Overall Maximum Deflections
Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
+D+L 0.4748 8.562 0.0000 0.000
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
I Wood Beam
LIC#: KW-06011582, Build:20.22.3.31 Envision Engineering, Inc.
DESCRIPTION: DECK JOISTS WITH 60 PSF
Vertical Reactions
Load Combination
Overall MAXImum
Overall MINimum
D Only
+D+L
+D+0.750L
+0.600
L Only
Support notation : Far left is #1
Support 1 Support 2
0.646 0.646
0.510 0.510
0.136 0.136
0.646 0.646
0.519 0.519
0.082 0.082
0.510 0.510
(c) ENERCALC INC 1983-2022
Values in KIPS
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID :
Project Descr:
5
!Wood Beam
UC#: KW-06011582, Build:20.22.3.31 Envision Engineering , Inc.
DESCRIPTION: FB4
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : IBC 2018
Material Properties
(c) ENERCALC INC 1983-2022
Analysis Method : Allowable Stress Design
Load Combination IBC 2018
Fb + 2900 psi E : Modulus of Elasticity
r
Wood Species
Wood Grade
Beam Bracing
iLevel Truss Joist
Parallam PSL 2.2E
Fb •
Fe· Prll
Fe -Perp
Fv
Ft
Beam is Fully Braced against lateral-torsional buckling
-----~D~0~.1_1~37....,,51L(0.525L
_______ D(Q.056
3.5x14.0
Span= 16.50 n
2900 psi Ebend-xx 2200ksi
2900 psi Eminbend -xx 1118.19ksi
750 psi
290 psi
2025 psi Density 45.07pcf
Applied Loads Service loads entered. Load Factors will be applied for calculations .
Beam self weight NOT internally calculated and added
Uniform Load : D = 0.0160 ksf, Tributary W idth = 3.50 ft
Uniform Load : D = 0.0130, L = 0.060 ksf, Tributary Width= 8.750 ft
P~$1(,,t,J _SU~MARY ............ .
Maximum Bending Stress Ratio = 0.856 1 Maximum Shear Stress Ratio
Section used for this span 3.5x14.0 Section used for this span
fb: Actual = 2,481.50psi fv: Actual
Fb: Allowable = 2,900.00psi Fv: Allowable
Load Combination +D+L Load Combination
Location of maximum on span = 8.250ft Location of maximum on span
Span# where maximum occurs = Span# 1 Span # where maximum occurs
Maximum Deflection
Max Downward Transient Deflection 0.500 in Ratio= 395 >=360 Span: 1 : L Only
Max Upward Transient Deflection 0 in Ratio= 0<360 n/a
Max Downward Total Deflection 0.662 in Ratio= 299 >=180 Span: 1 : +D+L
Max Upward Total Deflection O in Ratio= 0 <180 n/a
Maximum Forces & Stresses for Load Combinations
Load Combination l'illax Slress Ral1os lv'lomenl 'values
Segment Length Span# M V Cd CFN Ci Cr Cm Ct CL M fb
DOnly
Length= 16.50 ft 0.232 0.141 0.90 1.000 1.00 1.00 1.00 1.00 1.00 5.78 606.31
+D+L 1.000 1.00 1.00 1.00 1.00 1.00
Length = 16.50 ft 1 0.856 0.521 1.00 1.000 1.00 1.00 1.00 1.00 1.00 23.64 2,481.50
+D+0.750L 1.000 1.00 1.00 1.00 1.00 1.00
Length = 16.50 ft 0.555 0.338 1.25 1.000 1.00 1.00 1.00 1.00 1.00 19.18 2,012.71
+0.60D 1.000 1.00 1.00 1.00 1.00 1.00
Length= 16.50 ft 1 0.078 0.048 1.60 1.000 1.00 1.00 1.00 1.00 1.00 3.47 363.79
Overall Maximum Deflections
Load Combination Span Max. "." Defl Location in Span Load Combination
+D+L 1 0.6619 8.310
Desi n OK
= 0.521 : 1
3.5x14.0
= 151.13 psi
= 290.00 psi
+D+L
= 0.000 ft
= Span# 1
Sfiear 'values
F'b V fv F'v
0.00 0.00 0.00 0.00
2610.00 1.21 36.92 261 .00
0.00 0.00 0.00 0.00
2900.00 4.94 151.13 290.00
0.00 0.00 0.00 0.00
3625.00 4.00 122.58 362.50
0.00 0.00 0.00 0.00
4640.00 0.72 22.15 464.00
Max."+" Defl Location in Span
0.0000 0.000
\ Wood Beam
UC#: KW-06011582, Build:20.22.3.31
DESCRIPTION: FB4
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
D Only
+D+L
+D+0.750L
+0.60D
L Only
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
Envision Engineering, Inc. (c) ENERCALC INC 1983-2022
Support notation : Far left is #1 Values in KIPS
Support 1 Support 2
5.732 5.732
4,331 4.331
1.400 1.400
5.732 5,732
4.649 4,649
0.840 0.840
4.331 4.33 1
•
env1s1on e··--s . . engineering
STRUCTURAL ENGINEERS
565 PEARL ST. SUITE 209
LA JOLLA, CA 92037
858.246. 77 45
STRUCTURAL CALCULATIONS
DATE: 01/06/22
PROJECT: SHIRLEY REMODEL
DESIGNER: DTV DESIGNS
CBR2022-0255
2269 MASTERS RD
INTERIOR REMODEL KITCHEN/LIVING AREA (1200
SF)/8I-FOLD DOOR/DECK (323 SF)/PERGOLA (323 SF)
2121401000
1/26/2022
CBR2022-0255
Envision Engineering
L
La Jolla, CA 92037
J Building Code Information
UC#: KW-06011582, Build:20.21 .12.16
Governing Code
City Jurisdiction
Contact Name
Alternate Contact :
Building Official
Address
Phone
Notes
FLOOR/DECK DL = 13 PSF
FLOOR LL= 40 PSF
EXT. WALL DL= 16 PSF
Project Title:
Engineer:
Project ID:
Project Descr:
Envision Engineering, Inc. (c) ENERCALC INC 1983-2021
Fax : eMail
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
j ASCE 7-16 Seismic Base Shear
UC#: KW-06011582, Build:20.21.12.16 Envision Engineering, Inc. (c) ENERCALC INC 1983-2021
DESCRIPTION: Seismic Base Shear Analysis
Specific Description: SEISMIC FORCES
Risk Category Calculations per ASCE 7-16
Risk Category of Building or Other Structure : "II": All Buildings and other structures except those listed as Category SCE 7-16, Page 4, Table 1.!~1
I, Ill, and IV
Seismic Importance Factor 1 ASCE 7-16. Page 5, Table 1.5-2
Gridded Ss & S1values from ASCE 7-16 ASCE 7-16 11.4.2
Max. Ground Motions, 5% Damping Location Carlsbad, CA 92008
S s 1.011 g, 0.2 sec response
S 1 0.3686 g, 1.0 sec response Latitude = 33.158 deg North
Longitude = 117 .326 deg West
For the closest datapoint grid location ...
Latitude = 33.160 deg North
Longitude = 117 .320 deg West
Site Class, Site Coeff. and Design Category
Site ClassiftcatioYD" : Shear Wave Velocity 600 to 1,200 ft/sec
Site Coefficients Fa & Fv Fa
(using straight-line interpolation from table val
Maximum Considered Earthquake Accelerat
Design Spectral Acceleration
Seismic Design Category
Resistin S stem
Fv
SMS =Fa. Ss
SM1 =Fv*S1
SDS = SMS • 213
S01 = SM1 • 213
=
=
=
=
D (By Default per 11.4.3)
1.20
1.93
1.213
0.712
0.809
0.475
D
ASCE 7-16 Table 20.3-1
ASCE 7-16 Table 11.4-1 & 11.4-2
ASCE 7-16 Eq. 11.4-1
ASCE 7-16 Eq. 11.4-2
ASCE 7-16 Eq. 11.4-3
ASCE 7-16 Eq. 11.4-4
E 7-16 Table 11.6-1 & -2
ASCE 7-16 Table 12.2-1
Basic Seismic Force Resisting System ...
Response Modification Coefficient " I
System Overstrength Factor "Wo"
Deflection Amplification Factor " Cd '
Cantilevered column systems detailed to conform to specific classification
2.Steel ordinary cantilever column systems
1.25 Building height Limits :
1.25 Category "A & B" Limit:
Category "C" Limit:
Category "'D" Limit: 1.25
Category "E" Limit:
Category "F" Limit: NOTE! See ASCE 7-16 for all applicable footnc
Lateral Force Procedure
Equivalent Lateral Force Procedure
Limit= 35
Limit= 35
Not Permitted ,i
Not Permitted ,i
Not Permitted ,i
ASCE 7-16 Section 12.8.2
The "Equivalent Lateral Force Procedure" is being used according to the provisions of ASCE 7-16 12.8
Determine Buildin Period Use ASCE 12.8-7
Structure Type for Building Period CalculcAII Other Structural Systems
" Ct "value 0.020 "hn " : Height from base to highest leve 10.0 ft
11 x II value 0.75
"Ta" Approximate fundemental period using Eq. 12.8-7 : Ta= Ct• (hn • x) = 0.112 sec
8.000 sec "TL": Long-period transition period per ASCE 7-16 Maps 22-14 -> 22-17
" Cs " Response Coefficient
s05 : Short Period Design Spectral Response
"R": Response Modification Factor
"I": Seismic Importance Factor
=
=
=
Building Period" Ta " Calculated from Approximate Method selt= 0.112
0.809
1.25
ASCE 7-1 6 Section 12.8.1. 1
From Eq. 12.8-2 , Preliminary Cs = 0.647
From Eq. 12.8-3 & 12.8-4 , Cs need not excee = 3.376
From Eq. 12.8-5 & 12.8-6, Cs not be less than = 0.036
Cs : Seismic Response Coefficient = = 0.6470
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID :
Project Descr:
j ASCE 7-16 Seismic Base Shear
UC#: KW-06011582, Build:20.21.12.1 6 Envision Engineering, Inc.
DESCRIPTION: Seismic Base Shear Analysis
Seismic Base Shear
Cs= 0.6470 from 12.8.1 .1
Vertical Distribution of Seismic Forces
"k": hx exponent based on Ta= 1.00
Table of building Weights by Floor Leve/ ...
W ( see Sum Wi below ) =
Seismic Base Shear V = Cs * W =
(c) ENERCALC INC 1983-2021
ASCE 7-16 Section 12.8.1
0.00 k
0.00 k
ASCE 7-16 Section 12.8.3
Level# Wi :Weight Hi : Height (Wi * Hi"k) Cvx Fx=Cvx • V Sum Story Shear Sum Story Moment
Sum Wi = 0.00 k Sum Wi * Hi = 0.00 k-ft Total Base Shear= 0.00 k
Base Moment = 0.0 k-ft
Diaphragm Forces : Seismic Design Cate o "B" to "F" ASCE 7-16 12.10.1.1
Level# Wi Fi Sum Fi SumWi Fpx : Calcd Fpx : Min Fpx : Max
Wpx . . . . . . . . . . . . . . . . . . . . Weight at level of diaphragm and other structure elements attached to it.
Fi . . . . . . . . . . . . . . . . . . . . . . Design Lateral Force applied at the level.
Sum Fi . . . . . . . . . . . . . . . . . . Sum of "Lat. Force" of current level plus all levels above
MIN Req'd Force @ Level . . . 0.20 *Sos * I * Wpx
MAX Req'd Force @ Level ... 0.40 *Sos * I * Wpx
Fpx : Design Force@ Level . Wpx * SUM(x->n) Fi / SUM(x->n) wi, x = Current level, n = Top Level
Lateral Seismic Analysis
Vbase=13 psf x (18'x18')x 0.6470 = 3.1 K
Vasd/per col = 0.7x3.1 K/4= 0.550 K per column (See Column Analysis)
At existing exterior wall with redundancy = 1.3
Fp=0.4SdsxWxlp= 0.4x 0.809x [13psf x (36'x10'+18'x9') + 16 psf x (36'x5')) = 3128 lbs
Fp asd = 1.3 x 0.7 x 3128 lbs= 2846 lbs
New Shearwall L = 6'-6"
v=2846/6.5'= 438 pit USE TYPE 5 SHEARWALL
Mor= 2846 x 1 0' = 28.46 Kip-ft
Mr=0
T = 4.4 K USE HDU4 HOLDOWN
Fpx Dsgn. Force
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
I Wood Beam
LIC#: KW-0601 1582, Build:20.21.12.16 Envision Engineering. Inc.
DESCRIPTION: FB1
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : IBC 2018
Material Properties
(c) ENERCALC INC 1983-2021
Analysis Method : Allowable Stress Design
Load Combination IBC 2018
Fb +
Fb -
2900 psi
2900 psi
2900 psi
E : Modulus of Elasticity
Wood Species
Wood Grade
Beam Bracing
iLevel Truss Joist
Parallam PSL 2.0E
Completely Unbraced
Fe -Prll
Fe -Perp
Fv
Ft
D 0.156 L 0.48
5.25x11.875
Span = 16.50 ft
750 psi
290 psi
2025 psi
Ebend-xx 2000ksi
Eminbend -xx 1016.535ksi
Density 45.07pcf
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.0130, L = 0.040 ksf, Tributary Width = 12.0 ft
P!;..$!GN SUMMARY ............... __ _ Desi n OK
Maximum Bending Stress Ratio = 0.747. 1 Maximum Shear Stress Ratio = 0.384 ; 1
Section used for this span 5.25x11.875 Section used for this span 5.25x11.875
fb: Actual = 2,104.95psi fv: Actual = 111.50 psi
Fb: Allowable = 2,819.72psi Fv: Allowable = 290.00 psi
Load Combination +D+L Load Combination +D+L
Location of maximum on span = 8.250ft Location of maximum on span = 0.000ft
Span# where maximum occurs = Span# 1 Span # where maximum occurs = Span# 1
Maximum Deflection
Max Downward Transient Deflection 0.550 in Ratio= 360 >=360 Span: 1 : L Only
Max Upward Transient Deflection O in Ratio= 0 <360 n/a
Max Downward Total Deflection 0.728 in Ratio= 271 >=180 Span: 1 : +D+L
Max Upward Total Deflection 0 in Ratio= 0<180 n/a
Maximum Forces & Stresses for Load Combinations
Load Combination l'Jlax Slress Ralios Momeni 'values Sfiear 'values
Segment Length Span# M V Cd CFN Ci Cr Cm Ct CL M fb F'b V fv F'v
D Only 0.00 0.00 0.00 0.00
Length = 16.50 ft 1 0.203 0.105 0.90 1.000 1.00 1.00 1.00 1.00 0.98 5.31 516.31 2547.86 1.14 27.35 261 .00
+D+L 1.000 1.00 1.00 1.00 1.00 0.98 0.00 0.00 0.00 0.00
Length = 16.50 ft 0.747 0.384 1.00 1.000 1.00 1.00 1.00 1.00 0.97 21.64 2,104.95 2819.72 4.63 111.50 290.00
+D+0.750L 1.000 1.00 1.00 1.00 1.00 0.97 0.00 0.00 0.00 0.00
Length = 16.50 ft 1 0.490 0.250 1.25 1.000 1.00 1.00 1.00 1.00 0.96 17.56 1,707.79 3483.50 3.76 90.46 362.50
+0.600 1.000 1.00 1.00 1.00 1.00 0.96 0.00 0.00 0.00 0.00
Length= 16.50 ft 1 0.071 0.035 1.60 1.000 1.00 1.00 1.00 1.00 0.94 3.19 309.78 4361.15 0.68 16.41 464.00
Overall Maximum Deflections
Load Combination Span Max. "-" Dell Location in Span Load Combination Max. "+" Dell Location in Span
+D+L 0.7281 8.310 0.0000 0.000
I Wood Beam
UC#: KW-06011582, Build:20.21.12.16
DESCRIPTION: FB1
Vertical Reactions
Load Combination
Overall MAX1mum
Overall MINimum
D Only
+D+L
+D+0.750L
+0.600
L Only
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
Envision Engineering, Inc. (c) ENERCALC INC 1983-2021
Support notation : Far left is #1 Values in KIPS
Support 1 Support 2
5.247 5.247
3.960 3.960
1.287 1.287
5.247 5.247
4.257 4.257
0.772 0.772
3.960 3.960
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
j Wood Beam
UC# : KW-06011582, Build:20.21.12.16 Envision Engineering, Inc.
DESCRIPTION: FB2
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : IBC 2018
Material Properties
(c) ENERCALC INC 1983-2021
Analysis Method : Allowable Stress Design
Load Combination IBC 2018
Fb +
Fb -
2,900.0 psi
2,900.0 psi
2,900.0 psi
E : Modulus of Elasticity
Wood Species
Wood Grade
Beam Bracing
iLevel Truss Joist
Parallam PSL 2.0E
Completely Unbraced
.................. ,M ... R ... ,mm,oo, -------------
Fe -Prll
Fe -Perp
Fv
Ft
0 0.156 LO 48
3.5x11 .875
Span = 12.0 ft
750.0 psi
290.0 psi
2,025.0 psi
Ebend-xx 2,000.0ksi
Eminbend-xx 1,016.54ksi
Density 45.070pcf
A lied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.0130, L = 0.040 ksf, Tributary W idth = 12.0 ft
DESIGN SUMMARY -------------•■■~•$~-Bf•Di,11!•1~:■■■
Maximum Bending Stress Ratio
Section used for this span
lb: Actual
Fb: Allowable
Load Combination
Location of maximum on span
Span# where maximum occurs
Maximum Deflection
=
=
=
=
0.616 1
3.5x11.875
1,670.04psi
2,710.95psi
+D+L
6.000ft
Span# 1
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
0.231 in Ratio=
O in Ratio=
0.306 in Ratio=
Max Upward Total Deflection O in Ratio=
Maximum Forces & Stresses for Load Combinations
Max Stress Ratios Load Combination
Segment Length Span # M V Cd C FN
D Only
Length = 12.0 ft
+D+L
Length = 12.0 ft
+D+0.750L
Length = 12.0 ft
+0.600
1 0.166 0.109 0.90
1 0.616 0.399 1.00
1 0.417 0.259 1.25
Length= 12.0 ft 1 0.065 0.037 1.60
Overall Maximum Deflections
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.00 1.00
1.00 1.00
1.00 1.00
1.00 1.00
1.00 1.00
1.00 1.00
1.00 1.00
Maximum Shear Stress Ratio
Section used for this span
fv: Actual
Fv: Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
624>=360 Span: 1 : L Only
0 <360 n/a
471 >=180 Span : 1 : +D+L
0<180 nla
Moment 'values
M lb
1.00 1.00 0.95 2.81 409.63
1.00 1.00 0.95
1.00 1.00 0.93 11.45 1,670.04
1.00 1.00 0.93
1.00 1.00 0.90 9.29 1,354.94
1.00 1.00 0.90
1.00 1.00 0.82 1.68 245.78
Load Combination Span Max. "-" Dell Location in Span Load Combination
+D+L 0.3055 6.044
=
=
=
=
=
F'b
0.00
2470.32
0.00
2710.95
0.00
3249,35
0.00
3798.04
0.399: 1
3.5x11.875
115.60 psi
290.00 psi
+D+L
0.000ft
Span# 1
Sfiear 'values
V fv F'v
0.00 0.00 0.00
0.79 28.36 261.00
0.00 0.00 0.00
3.20 115.60 290.00
0.00 0.00 0.00
2.60 93.79 362.50
0.00 0.00 0.00
0.47 17.01 464.00
Max. "+" Deft Location in Span
0.0000 0.000
!wood Beam
UC#: KW-06011582, Build:20.21.12.16
DESCRIPTION: FB2
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
D Only
+D+L
+D+0.750L
+0.60D
L Only
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
Envision Engineering. Inc. (c) ENERCALC INC 1983-2021
Support notation : Far left is #1 Values in KIPS
Support 1 Support 2
3.816 3.816
2.880 2.880
0.936 0.936
3.816 3.816
3.096 3.096
0.562 0.562
2.880 2.880
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
!wood Beam
UC#: KW-06011582, Build:20.21 .12.16 Envision Engineering, Inc.
DESCRIPTION: FB3
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : IBC 2018
Material Pro erties
(c) ENERCALC INC 1983-2021
Analysis Method : Allowable Stress Design
Load Combination IBC 2018
Fb +
Fb-
2,900.0 psi
2,900.0 psi
2,900.0 psi
£ : Modulus of Elasticity
Wood Species
Wood Grade
Beam Bracing
iLevel Truss Joist
Parallam PSL 2.0E
Completely Unbraced
0(1) (2.9)
Fc -Prll
Fe -Perp
Fv
Ft
D 0.01729 L 0.0532
3.5x11.875
Span ; 14.0 ft
750.0 psi
290.0 psi
2,025.0 psi
Ebend-xx 2,000.0ksi
Eminbend-xx 1,016.54ksi
Density 45.070pcf
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.0130, L = 0.040 ksf,
Point Load : D = 1.0, L = 2.90 k @ 6.0 ft
Tributary Width = 1.330 ft
QESIGN 8-.VM.M./t-=R-'--'Y'------------------------
Maximum Bending Stress Ratio = 0.826 1 Maximum Shear Stress Ratio
Section used for this span 3.5x11.875 Section used for this span
fb: Actual = 2, 190.60psi fv: Actual
Fb: Allowable = 2,651 .53psi Fv: Allowable
Load Combination +D+L Load Combination
Location of maximum on span = 6.029ft Location of maximum on span
Span # where maximum occurs = Span# 1 Span # where maximum occurs
Maximum Deflection
Max Downward Transient Deflection 0.334 in Ratio= 502 >=360 Span: 1 : L Only
Max Upward Transient Deflection O in Ratio= 0 <360 n/a
Max Downward Total Deflection 0.449 in Ratio= 374 >=180 Span: 1 : +D+L
Max Upward Total Deflection O in Ratio= 0 <180 nla
Maximum Forces & Stresses for Load Combinations
Load Combination II/lax Stress Ral1os l'illomenl IJalues
Segment Length Span# M V Cd CFN Ci Cr Cm Ct CL M fb
DOnly
Length= 14.0 fl 0.230 0.093 0.90 1.000 1.00 1.00 1.00 1.00 0.93 3.83 558.94
+D+L 1.000 1.00 1.00 1.00 1.00 0.93
Length= 14.0 fl 0.826 0.330 1.00 1.000 1.00 1.00 1.00 1.00 0.91 15.02 2,190.60
+D+0.750L 1,000 1.00 1.00 1.00 1.00 0.91
Length= 14.0 fl 0.572 0.215 1.25 1.000 1.00 1.00 1.00 1.00 0.86 12.22 1,782.69
+0.60D 1.000 1.00 1.00 1.00 1.00 0.86
Length = 14.0 ft 1 0.095 0.032 1.60 1.000 1.00 1.00 1.00 1.00 0.76 2.30 335.37
Overall Maximum Deflections
Load Combination Span Max. "-" Dell Location in Span Load Combination
+D+L 1 0.4487 6.745
=
=
=
=
=
F'b
0.00
2429.65
0.00
2651 .53
0,00
3114.99
0.00
3516.20
0.330: 1
3.5x11.875
95.77 psi
290.00 psi
+D+L
0.000ft
Span# 1
Sfiear IJalues
V fv F'v
0.00 0.00 0.00
0.68 24.39 261 .00
0.00 0.00 0.00
2.65 95.77 290.00
0.00 0.00 0.00
2.16 77.92 362.50
0.00 0.00 0.00
0.41 14.63 464.00
Max."+" Defl Location in Span
0.0000 0.000
a
F
I Wood Beam
UC#: KW-06011 582, Build:20.21.12.16
DESCRIPTION: FB3
Vertical Reactions
Load Combination
Overall MAX,mum
Overall MINimum
D Only
+D+L
+D+0.750L
+0.60D
L Only
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
Envision Engineering, Inc. (c) ENERCALC INC 1983-2021
Support notation : Far left is #1 Values in KIPS
Support 1 Support 2
2.722 2.165
2.030 1.615
0.692 0.550
2.722 2.165
2.215 1.761
0.415 0.330
2.030 1.615
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
I Wood Beam
LIC#: KW-06011582. Build:20.21.12.16
DESCRIPTION: FB4
Envision Engineering, Inc.
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : IBC 2018
Material Properties
(c) ENERCALC INC 1983-2021
Analysis Method : Allowable Stress Design
Load Combination IBC 2018
Fb +
Fb -
2900 psi
2900 psi
2900 psi
E : Modulus of Elasticity
Wood Species
Wood Grade
Beam Bracing
Ii
iLevel Truss Joist
Parallam PSL 2.0E
Completely Unbraced
Fe -Prll
Fe -Perp
Fv
Ft
750 psi
290 psi
2025 psi
D(0.1137;) L_~0~.3~5~------
D 0.056
3.5X14.0
Span = 16.50 ft
Ebend-xx 2000ksi
Eminbend -xx 1016.535ksi
Density 45.07pcf
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.0160 ksf, Tributary Width = 3.50 ft
Uniform Load : D = 0.0130, L = 0.040 ksf, Tributary Width = 8. 750 ft
DESIGN SUMM-=J!l'--'-R'-'--'-Y __________________ _
Maximum Bending Stress Ratio = 0.780 1 Maximum Shear Stress Ratio
Section used for this span 3.5x14.0 Section used for this span
fb: Actual = 1,856.44psi fv: Actual
Fb: Allowable = 2,380.68psi Fv: Allowable
Load Combination +D+L Load Combination
Location of maximum on span = 8.250fl Location of maximum on span
Span # where maximum occurs = Span# 1 Span # where maximum occurs
Maximum Deflection
Max Downward Transient Deflection 0.367 in Ratio= 539 >=360 Span: 1 : L Only
Max Upward Transient Deflection O in Ratio= 0 <360 nla
Max Downward Total Deflection 0.545 in Ratio= 363>=180 Span: 1 : +D+L
Max Upward Total Deflection O in Ratio= 0 <180 nla
Maximum Forces & Stresses for Load Combinations
Load Combination lli'lax S!ress Ra!1os lli'lomen! IJalues
Segment Length Span# M V Cd CFN Ci Cr Cm C t CL M fb
DOnly
Length = 16.50 fl 0.270 0.141 0.90 1.000 1.00 1.00 1.00 1.00 0.86 5.78 606.31
+D+L 1.000 1.00 1.00 1.00 1.00 0.86
Length = 16.50 fl 0.780 0.390 1.00 1.000 1.00 1.00 1.00 1.00 0.82 17.69 1,856.44
+D+0.750L 1.000 1.00 1.00 1.00 1.00 0.82
Length = 16.50 fl 0.594 0.259 1.25 1.000 1.00 1.00 1.00 1.00 0.72 14.71 1,543.91
+0.60D 1.000 1.00 1.00 1.00 1.00 0.72
Length = 16.50 fl 1 0.1 33 0.048 1.60 1.000 1.00 1.00 1.00 1.00 0.59 3.47 363.79
Overall Maximum Deflections
Load Combination Span Max. "-" Deft Location in Span Load Combination
+D+L 1 0.5447 8.310
=
=
=
=
=
F'b
0.00
2242.41
0.00
2380.68
0.00
2597.84
0.00
2731.01
Desi n OK
0.390 : 1
3.5x14.0
113.06 psi
290.00 psi
+D+L
0.000 fl
Span# 1
Sliear 17alues
V fv F'v
0.00 0.00 0.00
1.21 36.92 261 .00
0.00 0.00 0.00
3.69 113.06 290.00
0.00 0.00 0.00
3.07 94.03 362.50
0.00 0.00 0.00
0.72 22.15 464.00
Max."+" Deft Location in Span
0.0000 0.000
I Wood Beam
UC#: KW-06011582, Build:20.21.12.16
DESCRIPTION: FB4
Vertical Reactions
Load Combination
Overall MAX1mum
Overall MINimum
D Only
+D+L
+D+0.750L
+0.60D
LOnly
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
Envision Engineering, Inc. (c) ENERCALC INC 1983-2021
Support notation : Far left is #1 Values in KIPS
Support 1 Support 2
4.288 4.288
2.888 2.888
1.400 1.400
4.288 4.288
3.566 3.566
0.840 0.840
2.888 2.888
e n
L a
!wood Beam
a
F
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
LIC#: KW-06011582, Build:20.21 .12.16 Envision Engineering, Inc.
DESCRIPTION: HDR1
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : IBC 2018
Material Properties
(c) ENERCALC INC 1983-2021
Analysis Method : Allowable Stress Design
Load Combination IBC 2018
Fb +
Fb -
2,900.0 psi
2,900.0 psi
2,900 .0psi
E : Modulus of Elasticity
Wood Species
Wood Grade
Beam Bracing
iLevel Truss Joist
Parallam PSL 2.0E
Completely Unbraced
Fe -Prll
Fe -Perp
Fv
Ft
750.0 psi
290.0 psi
2,025.0 psi
Ebend-xx 2,000.0ksi
Eminbend -xx 1,016.54ksi
Density 45.070pcf
~ -----oJQ_,;44) __________ ~---------
o 0.0845 L 0.26
3.5x11.875 l
Span = 16.0 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.0130, L = 0.040 ksf, Tributary Width = 6 .50 ft
Uniform Load : D = 0.0160 ksf, Tributary Width= 9.0 ft
DESIGN SUMMARY ---------------------------Maximum Bending Stress Ratio
Section used for this span
= 0.888 1 Maximum Shear Stress Ratio
fb: Actual
Fb: Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
=
=
3.5x11.875
2,280.40psi
2,568.17 psi
+D+L
8.000fl
Span# 1
0.395 in Ratio=
O in Ratio=
0.742 in Ratio=
0 in Ratio=
Maximum Forces & Stresses for Load Combinations
Load Combination lii'lax Slress Ral1os
Segment Length Span# M V Cct CFN Ci Cr
DOnly
Length = 16.0 fl 0.449 0.223 0.90 1.000 1.00 1.00
+D+L 1.000 1.00 1.00
Length = 16.0 fl 0.888 0.430 1.00 1.000 1.00 1.00
+D+0.750L 1.000 1.00 1.00
Length = 16.0 fl 1 0.673 0.298 1.25 1.000 1.00 1.00
+0.60D 1.000 1.00 1.00
Length = 16.0 fl 1 0.200 0.075 1.60 1.000 1.00 1.00
Overall Maximum Deflections
Section used for this span
fv: Actual
Fv: Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
486 >=360 Span: 1 : L Only
O <360 n/a
258>=180 Span: 1 : +D+l
0 <180 n/a
lii'lomenl 'i7alues
Cm Ct CL M fb
1.00 1.00 0.91 7.31 1,066.68
1.00 1.00 0.91
1.00 1.00 0.89 15.63 2,280.40
1.00 1.00 0.89
1.00 1.00 0.81 13.55 1,976.97
1.00 1.00 0.81
1.00 1.00 0.69 4.39 640.01
Load Combination Span Max. "-" Def! Location in Span Load Combination
+D+L 1 0.7417 8.058
Desi n OK
= 0.430 : 1
3.5x11.875
= 124.57 psi
= 290.00 psi
+D+L
= 15.066 fl
= Span# 1
Sfiear 'i7alues
F'b V fv F'v
0.00 0.00 0.00 0.00
2373.14 1.61 58.27 261.00
0.00 0.00 0.00 0.00
2568.17 3.45 124.57 290.00
0.00 0.00 0.00 0.00
2936.18 2.99 107.99 362.50
0.00 0.00 0.00 0.00
3204.36 0.97 34.96 464.00
Max."+" Def! Location in Span
0.0000 0.000
j Wood Beam
UC# : KW-06011582, Build:20.21 .12.16
DESCRIPTION: HDR1
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
D Only
+D+L
+D+0.750L
+0.60D
L Only
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
Envision Engineering, Inc. (c) ENERCALC INC 1983-2021
Support notation : Far left is #1 Values in KIPS
Support 1 Support 2
3.908 3.908
2.080 2.080
1.828 1.828
3.908 3.908
3.388 3.388
1.097 1.097
2.080 2.080
e::: Envision Engineering
La Jolla, CA 92037
Project Title:
Engineer:
Project ID:
Project Descr:
I Wood Beam
LIC#: KW-06011582. Build:20.21.12.16 Envision Engineering, Inc.
DESCRIPTION: HDR2
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : IBC 2018
Material Properties
(c} ENERCALC INC 1983-2021
Analysis Method : Allowable Stress Design
Load Combination IBC 2018
Fb +
Fb -
900.0 psi
900.0 psi
E : Modulus of Elasticity
Wood Species
Wood Grade
Beam Bracing
Douglas Fir-Larch
No.2
Completely Unbraced
Fe -Prll
Fe -Perp
Fv
Ft
Spen: 5.50 fl
1,350.0 psi
625.0 psi
180.0 psi
575.0 psi
Ebend-xx 1,600.0ksi
Eminbend -xx 580.0ksi
Density 31 .210pcf
A lied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.0130, L = 0.040 ksf, Tributary Width = 6.50 ft
Uniform Load : D = 0.0160 ksf, Tributary Width = 9.0 ft
Uniform Load : D = 0.0130, L = 0.040 ksf, Tributary Width = 8.750 ft
DESIGN SUMMARY OH..... • ........... .
Maximum Bending Stress Ratio
Section used for this span
0.597: 1 Maximum Shear Stress Ratio
fb: Actual
Fb: Allowable
Load Combination
=
=
Location of maximum on span =
Span # where maximum occurs =
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
4x12
585.26psi
979.56psi
+D+L
2.750ft
Span# 1
0.019 in Ratio =
O in Ratio=
0.030 in Ratio=
0 in Ratio=
Maximum Forces & Stresses for Load Combinations
Load Combination l'Jlax Slress Ral1os
Segment Length Span# M V Cd CFN Ci Cr
D Only
Length= 5.50 ft 1 0.238 0.147 0.90 1.100 1.00 1.00
+D+L 1.100 1.00 1.00
Length = 5.50 ft 1 0.597 0.368 1.00 1.100 1.00 1.00
+D+0.750L 1.100 1.00 1.00
Length = 5.50 ft 0.403 0.247 1.25 1.100 1.00 1.00
+0.60D 1.100 1.00 1.00
Length = 5.50 ft 1 0.081 0.050 1.60 1.100 1.00 1.00
Overall Maximum Deflections
Section used for this span
fv: Actual
Fv: Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
3471 >=360 Span: 1 : L Only
0 <360 nla
2223 >=1 80 Span: 1 : +D+L
0 <1 80 n/a
l'Jlomen! 'values
Cm Ct CL M fb
1.00 1.00 0.99 1.29 21 0.35
1.00 1.00 0.99
1.00 1.00 0.99 3.60 585.26
1.00 1.00 0.99
1.00 1.00 0.99 3.02 491 .53
1.00 1.00 0.99
1.00 1.00 0.98 0.78 126.21
Load Combination Span Max. "-" Defl Location in Span Load Combination
+D+L 0.0297 2.770
= 0.368 : 1
4x12
= 66.26 psi
= 180.00 psi
+D+L
= 4.577 ft
= Span# 1
Sfiear 'values
F'b V fv F'v
0.00 0.00 0.00 0.00
882.70 0.63 23.82 162.00
0.00 0.00 0.00 0.00
979.56 1.74 66.26 180.00
0.00 0.00 0.00 0.00
1220.40 1.46 55.65 225.00
0.00 0.00 0.00 0.00
1553.97 0.38 14.29 288.00
Max. "+" Defl Location in Span
0.0000 0.000
I Wood Beam
LIC# : KW-06011582. Build:20.21 .12.16
DESCRIPTION: HDR2
Vertical Reactions
Load Combination
Overall MAX1mum
Overall MINimum
D Only
+D+L
+D+0.750L
+0.60D
L Only
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
Envision Engineering, Inc. (c) ENERCALC INC 1983-2021
Support notation : Far left is #1 Values in KIPS
Support 1 Support 2
2.619 2.619
1.678 1.678
0.941 0.941
2.619 2.619
2.199 2.199
0.565 0.565
1.678 1.678
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
!wood Beam
LIC#: KW-06011582, Build:20.21.12.16 Envision Engineering, Inc.
DESCRIPTION: TYP. PERGOLA BEAM
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : IBC 2018
Material Properties
(c) ENERCALC INC 1983-2021
Analysis Method : Allowable Stress Design
Load Combination · IBC 2018
Fb +
Fb -
1350 psi
1350 psi
925 psi
625 psi
170 psi
675 psi
E : Modulus of Elasticity
Wood Species
Wood Grade
Beam Bracing
Douglas Fir-Larch
No.1
Completely Unbraced
v
Fe -Prll
Fe -Perp
Fv
Ft
D(0.0875~Lr(0.175)
6x 14
Span= 16.50 ft
Ebend-xx 1600 ksi
Eminbend -xx 580ksi
Density 31 .21 pcf
1
A lied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load: D = 0.010, Lr = 0.020 ksf, Tributary Width = 8.750 ft
Q~$.!GN SUMMJ.!.B.¥. ....... .. Desi n OK
Maximum Bending Stress Ratio = 0.392 1 Maximum Shear Stress Ratio = 0.179: 1
Section used for this span 6x14 Section used for this span 6x14
fb : Actual = 641 .67psi fv: Actual = 38.00 psi
Fb: Allowable = 1,636.83psi Fv: Allowable = 212.50 psi
Load Combination +D+Lr Load Combination +D+Lr
Location of maximum on span = 8.250ft Location of maximum on span = 0.000ft
Span # where maximum occurs = Span# 1 Span # where maximum occurs = Span# 1
Maximum Deflection
Max Downward Transient Deflection 0.163 in Ratio= 1216 >=360 Span : 1 : Lr Only
Max Upward Transient Deflection O in Ratio= 0 <360 n/a
Max Downward Total Deflection 0.244 in Ratio= 811 >=180 Span: 1 : +D+Lr
Max Upward Total Deflection 0 in Ratio = 0 <180 n/a
Maximum Forces & Stresses for Load Combinations
Load Combination lli'lax Stress Ral1os lli'lomen! l:lalues Sfiear l}alues
Segment Length Span# M V Cd CFN Ci Cr Cm Ct CL M lb F'b V fv F'v
D Only 0.00 0.00 0.00 0.00
Length= 16.50 ft 1 0.179 0.083 0.90 0.987 1.00 1.00 1.00 1.00 0.98 2.98 213.89 1192.00 0.63 12.67 153.00
+D+Lr 0.987 1.00 1.00 1.00 1.00 0.98 0.00 0.00 0.00 0.00
Length= 16.50 ft 0.392 0.179 1.25 0.987 1.00 1.00 1.00 1.00 0.97 8.93 641.67 1636.83 1.88 38.00 212.50
+D+0.750Lr 0.987 1.00 1.00 1.00 1.00 0.97 0.00 0.00 0.00 0.00
Length= 16.50 ft 0.327 0.149 1.25 0.987 1.00 1.00 1.00 1.00 0.97 7.44 534.72 1636.83 1.57 31 .67 212 .50
+0.60D 0.987 1.00 1.00 1.00 1.00 0.97 0.00 0.00 0.00 0.00
Length= 16.50 ft 1 0.062 0.028 1.60 0.987 1.00 1.00 1.00 1.00 0.96 1.79 128.33 2063.92 0.38 7.60 272 .00
Overall Maximum Deflections
Load Combination Span Max. "-" Dell Location in Span Load Combination Max."+" Defl Location in Span
+D+Lr 1 0.2440 8.310 0.0000 0.000
Envision Engineering a
La Jolla, CA 92037
Project Title:
Engineer:
Project ID:
Project Descr: -I Wood Beam
LIC#: KW-06011582, Build:20.21.12.16 Envision Engineering, Inc.
DESCRIPTION: TYP. PERGOLA BEAM
Vertical Reactions Support notation : Far left is #1
Load Combination Support 1 Support 2
Overall MAX1mum
Overall MINimum
DOnly
+D+Lr
+D+0.750Lr
+0.60D
Lr Only
2.166 2.166
1.444 1.444
0.722 0.722
2.166 2.166
1.805 1.805
0.433 0.433
1.444 1.444
(c) ENERCALC INC 1983-2021
Values in KIPS
e:: Envision Engineering
La Jolla, CA 92037
Project Title:
Engineer:
Project ID:
Project Descr:
J Steel Column
LIC# : KW-06011582, Build:20.21.12.16 Envision Engineering, Inc. (c) ENERCALC INC 1983-2021
DESCRIPTION: TYP. COLUMN AT NEW DECK RESISTING SEISMIC LOAD
Code References
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : IBC 2018
General Information
Steel Section Name : HSS5x5x1/4 Overall Column Height 10.0 ft
Analysis Method : Allowable Strength Top & Bottom Fixity Top Free. Bottom Fixed
Steel Stress Grade
Fy : Steel Yield
Brace condition for deflection (buckling) along columns :
E : Elastic Bending Modulus
42.0 ksi
29,000.0 ksi
X-X (width) axis :
Unbraced Length for buckling ABOUT Y-Y Axis= 10 ft, K = 2.1
Y-Y (depth) axis :
Unbraced Length for buckling ABOUT X-X Axis = 10 ft, K = 2.1
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Column self weight included : 156.20 lbs • Dead Load Factor
AXIAL LOADS ...
Axial Load at 10.0 ft, Xecc = 1.0 in, Yecc = 1.0 in, D = 1.40, LR = 2.90 k
BENDING LOADS ...
Lat. Point Load at 10.0 ft creating Mx-x, E = 0.550 k
DESIGN SUMMARY
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio =
Load Combination
Location of max.above base
At maximum location values are ...
Pa : Axial
Pn / Omega : Allowabl1
Ma-x : Applied
Mn-x / Omega : Allowable
Ma-y : Applied
Mn-y / Omega : Allowable
PASS Maximum Shear Stress Rati,
Load Combination
Location of max.above base
At maximum location values are ...
Va : Applied
Vn / Omega : Allowable
Load Combination Results
0.2765 : 1
+D+0.70E o.o ft
1.556 k
37.911 k
-3.967 k-ft
15.949 k-ft
-0.1167 k-ft
15.949 k-ft
0.01 273 : 1
+D+0.70E
0.0 ft
0.3850 k
30.244 k
Maximum Axial + Bending Stress Ratios
Maximum Load Reactions ..
Top along X-X
Bottom along X-X
Top along Y-Y
Bottom along Y-Y
Maximum Load Deflections ...
Along Y-Y 0.6793 in at
for load combination : E Only
Along X-X 0.06628 in at
for load combination : +D+Lr
0.0 k
0.0 k
0.0 k
0.550 k
10.0ft above base
10.0ft above base
Load Combination Stress Ratio Status Location Cbx Cby KxLx/Ry KyLy/Rx
Maximum Shear Ratios
Stress Ratio Status Location
Maximum Reactions
Load Combination
Extreme Reactions
Item
Axial Reaction
@Base
Axial Reaction
Extreme Value @ Base
X-X Axis Reaction
@ Base @ Top
X-X Axis Reaction
@Base @Top
Maximum Deflections for Load Combinations
Load Combination
Steel Section Properties
Steel Section Properties
Max. X-X Deflection Distance
HSS5x5x1/4
HSS5x5x1/4
k Y-Y Axis Reaction
@ Base @Top
k Y-Y Axis Reaction
@ Base @ Top
Max. Y-Y Deflection
Note: Only non-zero reactions are listed.
Mx -End Moments k-ft My -End Moments
@ Base @ Top @ Base @ Top
Mx -End Moments k-ft My -End Moments
@ Base @ Top @ Base @ Top
Distance
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
5
/ Steel Column
LIC# : KW-06011582, Build:20.21.12.1 6 Envision Engineering, Inc.
DESCRIPTION: TYP. COLUMN AT NEW DECK RESISTING SEISMIC LOAD
Depth
Design Thick
Width
Wall Thick
Area
Weight
Ycg
Sketches
C:
i5 0
U")
5.000 in
0.233 in
5.000 in
0.250 in
4.300 inA2
15.620 pit
0.000 in
+Y
5.00in
I xx 16.00 inA4
s xx 6.41 inA3
R xx 1.930 in
Zx 7.610 inA3
I yy 16.000 inA4
s yy 6.410 inA3
R yy 1.930 in
Lecic 1
+X
"
(c) ENERCALC INC 1983-2021
J 25.800 inA4
C 10.500 jnA3
'''"
t
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
I General Footing
UC# : KW-06011582, Build:20.21.12.16 Envision Engineering. Inc. (c) ENERCALC INC 1983-2021
DESCRIPTION: TYP. F1 FOOTING
Code References
Calculations perACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : IBC 2018
General Information
Material Properties
fc : Concrete 28 day strength
fy : Rebar Yield =
Ee : Concrete Elastic Modulus
Concrete Density
(j) Values Flexure
Shear
Analysis Settings
Min Steel % Bending Reinf.
Min Allow% Temp Reinf.
Min. Overturning Safety Factor
Min. Sliding Safety Factor
Add Fig Wt for Soil Pressure
Use fig wt for stability, moments & shears
Add Pedestal Wt for Soil Pressure
Use Pedestal wt for stability, mom & shear
Dimensions
Width parallel to X-X Axis
Length parallel to Z-Z Axis
Footing Thickness
Pedestal dimensions ...
px : parallel to X-X Axis
pz : parallel to Z-Z Axis
Height
Rebar Centerline to Edge of Concrete ...
at Bottom of footing =
Reinforcin
Bars parallel to X-X Axis
Number of Bars
Reinforcing Bar Size #
Bars parallel to Z-Z Axis
Number of Bars
Reinforcing Bar Size #
2.50 ksi
60.0 ksi
3,122.0 ksi
145.0 pct
0.90
0.750
0.00180
2.0 ft
2.0 ft
12.0 in
in
in
in
3.0 in
3
5
3.0
5
C"")
1.0 : 1
1.0 : 1
Yes
Yes
No
No
Soil Design Values
Allowable Soil Bearing
Soil Density
Increase Bearing By Footing Weight
Soil Passive Resistance (for Sliding)
Soil/Concrete Friction Coeff.
Increases based on footing Depth
Footing base depth below soil surface
Allow press. increase per foot of depth
when footing base is below
Increases based on footing plan dimension
Allowable pressure increase per foot of depth
when max. length or width is greater than
X -_c;,
N
z
X
.-;;
----1..,_ .......... _=------o Q) C>
2'-0" "O w
3-#5 Bars
C"")
1.50 ksf
110.0pcf
No
250.0 pcf
0.30
ft
ksf
ft
ksf
ft
b I
Bandwidth Distribution Check (ACI 15.4.4.2)
Direction Requiring Closer Separation
n/a
n/a
n/a
X-X Section Looking to +Z Z-ec 10n Looking o + X
# Bars required within zone
# Bars required on each side of zone
Applied Loads
P : Column Load
OB : Overburden
D Lr
1.30
L s w
4.0
E H
k
ksf
-----------------•m•••••••-,.••••~""'"'.,'"'"'-••••-•••"' •• ---------•-----
M-xx
M-zz
V-x
V-z
k-ft
k-ft
k
k
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
I General Footing
UC#: KW-06011582, Build:20.21 .12.16 Envision Engineering, Inc. (c) ENERCALC INC 1983-2021
DESCRIPTION: TYP. F1 FOOTING
_D_E_S_I_G_N_S_U_M_M_A_R_Y _____________________________ ____, ..... #11-i•i•n--
Min. Ratio
PASS 0.980
PASS n/a
PASS n/a
PASS n/a
PASS n/a
PASS n/a
PASS 0.05625
PASS 0.05625
PASS 0.05625
PASS 0.05625
PASS 0.05896
PASS 0.05896
PASS 0.05896
PASS 0.05896
PASS 0.1401
Detailed Results
Soil Bearing
Rotation Axis &
Load Combination ...
X-X, 0 Only
X-X, +O+L
X-X, +0+0.750L
X-X, +0.600
Z-Z, 0 Only
Z-Z, +O+L
Z-Z, +0+0.750L
Z-Z, +0.600
Overturning Stability
Rotation Axis &
Load Combination ...
Footing Has NO Overturning
Sliding Stability
Force Application Axis
Load Combination ...
Footing Has NO Sliding
Footing Flexure
Item Applied
Soil Bearing 1.470 ksf
Overturning -X-X 0.0 k-ft
Overturning -Z-Z 0.0 k-ft
Sliding -X-X 0.0 k
Sliding -Z-Z 0.0 k
Uplift 0.0 k
Z Flexure (+X) 0.9950 k-ft/ft
Z Flexure (-X) 0.9950 k-ft/ft
X Flexure (+Z) 0.9950 k-ft/ft
X Flexure (-Z) 0.9950 k-ftlft
1-way Shear (+X) 4.422 psi
1-way Shear (-X) 4.422 psi
1-way Shear (+Z) 4.422 psi
1-way Shear (-Z) 4.422 psi
2-way Punching 21.020 psi
Xecc Zecc
Gross Allowable (in)
1.50 n/a 0.0
1.50 n/a 0,0
1.50 n/a 0.0
1.50 n/a 0.0
1.50 0.0 nla
1.50 0.0 n/a
1.50 0.0 n/a
1.50 0.0 n/a
Overturning Moment
Sliding Force
Capacity
1.50 ksf
0.0 k-ft
0.0 k-ft
0.0 k
0.0 k
0.0 k
17.688 k-ft/ft
17.688 k-ft/ft
17.688 k-ft/ft
17.688 k-ft/ft
75.0 psi
75.0 psi
75.0 psi
75.0 psi
150.0 psi
Governing Load Combination
+O+L about Z-Z axis
No Overturning
No Overturning
No Sliding
No Sliding
No Uplift
+1.200+1.60L
+1.200+1 .60L
+1 .200+1 .60L
+ 1.200+1.60L
+1.200+1 .60L
+1.200+1 .60L
+1.200+1.60L
+1.200+1.60L
+1.200+1.60L
Actual Soil Bearing Stress @ Location Actual / Allow
Bottom , -Z Top,+Z Left, -X Right, +X Ratio
0.470 0.470 n/a n/a 0.313
1.470 1,470 n/a n/a 0.980
1.220 1.220 n/a n/a 0.813
0.2820 0.2820 n/a n/a 0.188
n/a n/a 0.470 0.470 0.313
n/a n/a 1.470 1.470 0.980
n/a n/a 1.220 1.220 0.813
n/a n/a 0.2820 0.2820 0.188
Resisting Moment Stability Ratio Status
All units k
Resisting Force Stability Ratio Status
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phl•Mn Status k-ft Surface jnA2 in'2 in'2 k-ft
X-X, +1.400 0.2275 +Z Bottom 0.2592 AsMin 0.4650 17.688 OK
X-X, +1.400 0.2275 -Z Bottom 0.2592 AsMin 0.4650 17.688 OK
X-X, +1 .200+1 .60L 0.9950 +Z Bottom 0.2592 AsMin 0.4650 17.688 OK
X-X, + 1.200+ 1.60L 0.9950 -Z Bottom 0.2592 AsMin 0.4650 17.688 OK
X-X, + 1.200+0.50L 0.4450 +Z Bottom 0.2592 AsMin 0.4650 17.688 OK
X-X, +1.200+0.50L 0.4450 -Z Bottom 0.2592 AsMin 0.4650 17.688 OK
X-X, +1.200 0.1950 +Z Bottom 0.2592 AsMin 0.4650 17.688 OK
X-X, +1.200 0.1950 -Z Bottom 0.2592 AsMin 0.4650 17.688 OK
X-X, +0.900 0.1463 +Z Bottom 0.2592 AsMin 0.4650 17.688 OK
X-X, +0.900 0.1463 -Z Bottom 0.2592 AsMin 0.4650 17.688 OK
Z-Z. +1.400 0.2275 -X Bottom 0.2592 AsMin 0.4650 17.688 OK
Z-Z. +1.400 0.2275 +X Bottom 0.2592 AsMin 0.4650 17.688 OK
Z-Z. +1 .200+1 .60L 0.9950 -X Bottom 0.2592 AsMin 0.4650 17.688 OK
Z-Z, +1.200+1.60L 0.9950 +X Bottom 0.2592 AsMin 0.4650 17.688 OK
Z-Z, +1.200+0.50L 0.4450 -X Bottom 0.2592 AsMin 0.4650 17.688 OK
Z-Z, +1 .200+0.50L 0.4450 +X Bottom 0.2592 AsMin 0.4650 17.688 OK
Z-Z. +1.200 0.1950 -X Bottom 0.2592 AsMin 0.4650 17.688 OK
Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID:
Project Descr:
I General Footing
UC#: KW-06011582, Build:20.21.12.16 Envision Engineering, Inc. (c) ENERCALC INC 1983-2021
DESCRIPTION: TYP. F1 FOOTING
Footing Flexure
Flexure Axis & Load Combination
Z-Z, +1.200
Z-Z, +0.900
Z-Z, +0.900
One Way Shear
Mu
k-ft
0.1950
0.1463
0.1463
Side Tension
Surface
+X Bottom
-X Bottom
+X Bottom
As Req'd Gvrn. As
in'2 in'2
0.2592 AsMin
0.2592 AsMin
0.2592 AsMin
Actual As
in'2
0.4650
0.4650
0.4650
Phi*Mn
k-ft
17.688
17.688
17.688
Status
OK
OK
OK
Load Combination ... Vu@-X Vu@+X Vu @ -Z Vu @ +Z Vu:Max Phi Vn Vu/ Phi*Vn Status
+1.400
+ 1.200+ 1.60L
+1 .200+0.50L
+1.200
+0.900
Two-Way "Punching" Shear
Load Combination ...
+1.400
+1 .200+1.60L
+1 .200+0.50L
+1 .200
+0.900
1.01 psi
4.42 psi
1.98 psi
0.87psi
0.65 psi
Vu
1.01 psi
4.42 psi
1.98 psi
0.87 psi
0.65 psi
4.81 psi
21 .02 psi
9.40 psi
4.12 psi
3.09 psi
1.01 psi 1.01 psi 1.01 psi 75.00 psi 0.01
4.42 psi 4.42 psi 4.42 psi 75.00 psi 0.06
1.98 psi 1.98 psi 1.98 psi 75.00 psi 0.03
0.87 psi 0.87 psi 0.87 psi 75.00 psi 0.01
0.65 psi 0.65 psi 0.65 psi 75.00 psi 0.01
OK
OK
OK
OK
OK
All units k
Phi*Vn
150.00 psi
150.00 psi
150.00 psi
150.00psi
150.00psi
Vu/ Phi*Vn
0.03204
0.1401
0.06267
0.02746
0.0206
Status
OK
OK
OK
OK
OK
e n a Envision Engineering Project Title:
Engineer:
La Jolla, CA 92037 Project ID: ■ Project Descr: -I Pole Footing Embedded in Soil
LIC#: KW-06011582, Build:20.21 .12.16 Envision Engineering. Inc.
DESCRIPTION: TYP. NEW FOOTING FOR STEEL COLUMNS
Code References
Calculations per IBC 2018 1807.3, CBC 2019, ASCE 7-16
Load Combinations Used : IBC 2018
General Information
Pole Footing Shape Rectangular
Pole Footing Width . . . . . . . . . . . 24.0 in
Calculate Min. Depth for Allowable Pressures
Lateral Restraint at Ground Surface
Allow Passive .............. .
Max Passive ............... .
250.0 pcf
1,500.0 psf
Point Load
Controlling Values
Governing Load CombinatieD+O. ?OE
Lateral Load
Moment
Restraint @ Ground Surface
Pressure at Depth
Actual
Allowable
Surface Retrain! Force
Minimum RequlnKI Depth
Footing Base Area
Maximum Soil Pressure
A lied Loads
Lateral Concentrated Load (k)
D : Dead Load
Lr : Roof Live
L : Live
S : Snow
W :Wind
E : Earthquake
H : Lateral Earth
Load distance above
ground surface
k
k
k
k
k
0.550 k
k
10.0 ft
Load Combination Results
Load Combination
0.3850 k
3.850 k-ft
701.98 psf
718.75 psf
3,230.65 lbs
2.875 ft
4.0ft'2
1.073 ksf
Lateral Distributed Loads (k
TOP of Load above ground surface
BOTTOM of Load above ground surface
ounoS ace
Moments • (fl-k)
k/ft
k/ft
k/ft
k/ft
k/ft
k/ft
k/ft
ft
ft
Required
Depth" (ft)
D Only ------~---0.000 0.000 0.13
0.13
0.13
2.88
2.63
0.13
2.88
+D+L
+D+0.750L
+D+0.70E
+D+0.750L +0.5250E
+0.60D
+0.60D+0.70E
0.000
0.000
0.385
0.289
0.000
0.385
0.000
0.000
3.850
2.888
0.000
3.850
(c) ENERCALC INC 1983-2021
'i' o
.,...._,.,,...........,. ... s ... u.,.rf.,.a,...c ... e ... Lateral ,~estraint
Applied Moment (kft)
k-ft
k-ft
k-ft
k-ft
k-ft
k-ft
k-ft
.,....
0 .,....
-~~
Vertical Load (k)
1.40 k
k
2.890 k
k
k
k
k
Pressure a Depth olllncrease
Actual. -(psf) Allow • (psf) Factor
0.0 31 .3 1.000
0.0 31 .3 1.000
0.0 31 .3 1.000
702.0 718.8 1.000
631 .5 656.3 1.000
0.0 31.3 1.000
702.0 718.8 1.000