Loading...
HomeMy WebLinkAbout2864 VIA CONQUISTADOR; ; CB154288; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 01-07-2016 Cogeneration Permit Permit No:CB154288 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: 2864 VIA CONQUISTADOR CBAD COGEN Sub Type: PHOTO 2225922600 Lot #: 0 $15,200.00 Constuction Type: NEW Reference #: TAYLOR: ROOF MOUNT PV 10.07KW, 38 MODULES, NO PANEL UPGRADE, NORMA Owner: Status: ISSUED Applied: 12/07/2015 Entered By: SLE Plan Approved: 12/07/2015 Issued: 12/07/2015 Inspect Area: Plan Check #: SOLARCITY TAYLOR FAMILY TRUST 02-03-06 3055 CLEARVIEW WY SAN MATEO CA 94402 650-7 59-4658 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Green Bldg Stands (SB1473) Fee $167.81 $0.00 $117.47 $32.53 $0.00 $1.98 $1.00 2864 VIA CONQUISTADOR CARLSBAD CA 92009 PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $320.79 Total Fees: $320.79 Total Payments To Date: $320.79 Balance Due: $0.00 Inspector: Clearance: _____ _ t--OTlCE: Aa:Ee tale t--OTlCE M cW'M ci yar ptje:1 irdu:les the "lrrµ:sition" ci fees, oodcai0'1S, resaVcEO"lS, a-cfur exa:iicns rereater cx:Aledively reterroo to as 'fees/exa:iicns." Yru ha\€ 00 days fran the date ttis pcmit v..as issuoo to ~est irTµ)Sition ci trese fees/exa:iicns. If~ ~est Ihm ~ rru;t fdlONthe ~est procecires set fath in C:OJerrmrt Ore Section ffil20(a), a-d file the ~est a-d en/ ctta-ra:µroo irtamiion wth the Oty Mnaglr fa i:rooessirg in ~ wth Ca1stm M.rid!B Ore Section 3.32.mo. Falu-e to tirray fdlONM rrrorl.re wll l:H' en/ SlbiExµrt lega alien to atta::k. re.,iew, set asioo, lotid, a-cJYU thlir irllX)Sition. • Yru a-e t-a'IDj R.Rn-ffi t--OTlRED tt-at yar rigt to~ the sµ'cified fees/exa:ticns OCES t\OT ADA.. Y to waer a-d-cxrralion fees ard ~ty cta-ges, ra planirg, zoirg, gcdrg a-ctta-sinilar ,wicaion i:rooessirg cr service fees in cxrralion wth ttis ptje:1. 1'ffi cx:ES IT ADA.. Y to en/ fees/exa:iicns ci vhd1 ·rus1 ·1.e1 a t--OTl sirrilar to ttis or as to vhd1 tt-e staute ci lirritaions has ·rus1 ctta-wse 'roo. THE fOlltM••~ APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE· 0 PI.AHNIHG 0 EHGIHEERING □BUI.DING □FIRE □HEALTH 0 HAZMATIAPCO Plan Check No. Est. Value Plan Ck. Deposit (_ Ci~of Carlsbad Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www.car1sbadca.gov Date 12..--I SWPPP SUITU/SPACEI/UNIT, APN DESCRIPTION OF WORK: Include Squa,e Feet of Atrected Alu(S) K.W ,o . 01 PV Array Roof Mount; Modules bi; lnverter(s) I ; String(s) 3 Main Panel upgrade? ..Jo • Aush Mounted? N l> ; RMA? lf"5 EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIRE SPRINKLERS YES□No□ Amaya Salce 2370 Qak Ridge Way CrTY STATE ZIP Vista CA 92081 PHONE FAA PHONE 760-877..W38 EMAIL EMAIL asaJce@solarcity.com DESIGN PROFESSIONAL Same as Contractor CONTRACTOR BUS. NAME Solar Citv Coro. ADDRESS ADDRESS 3055 Clearview Way CrTY STATE ZIP CllY STATE ZIP San Mateo CA 94402 PHONE FAA PHONE FAA (650) 638-1028 EMAIL EMAIL asalce@solarcity.com STATE LIC. # STATE LIC.# Cl.ASS CllY BUS. LIC.# 888104 C.46. C1 1227803 (Sec. 7031.5 Business and Professions Code: Arry Ci1y or County which requires a permit to construct, alter, Improve, demolish or rllpalr anr structure, prior to Its Issuance, also requires the applicant for such permit to flle a si.11)1ed statement tfiat he Is licensed pursuant to the provisions of the Contractor"s License Law (Chapter 9, commending with S8ctlon 7000 of Division 3 of the Business and Professions Code) or that he Is exempt therefrom, and the basis for the alleg,:,d exemption. Any violation of Section 7031.5 by arry applicant for a permit subjects the applicant to • civll penally of not more than f,ve hundred dollars {$5001). w . blowing declarations: 0 I hava and wlll maintain a certificate workers' compensation as provided by Section 3700 of Iha labor Code, for lhe pelformance of lhe wor1< for which this permit Is Issued. IZJ I have and wm maintain workers' co 3700 of Iha Labor Code. for the performance of the wor1< for which this 1)811111t Is Issued. My workers' compensation Insurance canier and policy number ara: Insurance Co. • Canpany Polley No. WCt11211-MI IAOSI Expiration Date WIii& ')ll§.section need not be completed W lhe pennlt ($100) or less. LJ Celtlfk:ate of Exemption: I certify that in for which this permit ls Issued, I shall not employ any person in any manner so as to become subject to the Wor1<ers' Compensation Laws of carifomla WARNING: Failure to secure w coverage Is unlawful, and shaft subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensatlon, damag In Section 3706 of the Labor code, Interest and attorney's fees. _g CONTRACTOR SIGNATURE I het8by alllnn that I BIii exempt lrom ConllactQ"s License Law for the following reason: D I, as owner of the property or my employees with wages as their sole corr.,ensation, wil do the wor1< and the structure Is not intended or offered for sale (Sac. 7044, Business and Professions Code: The Contractor's Ucense Law does not apply to an owner of property who builds or Improves thereon, and who does such wor1< hlmsett or through his own employees, provided that such Improvements are not Intended or offered for sale. If, however, the buldlng or Improvement is sold wilhin one ye;y of completion, the owner-builder wll have the burden of proving thal he did not build or Improve for lhe purpose of sale). □ □ I, as owner of the property, an exclusively contractlng with lcensad contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's Ucense Law does not apply 10 an owner of property who builds or Improves theraon, and contracts for such projects with contractor(s) licensed pur$U8lll to the Conttactnr's License law). I an exempl under SectJon ____ Buslness and Professions Code for this reason: 1. I personaly plan to provide the major labor and materials for constructioll of the proposed property lmprovemenL 0 Yes C}«> 2. I (have I have not) signed an applk:atk>n for a building permit for Iha proposed wor1<. 3. I have contracted with the folowlng person (firm) to provide the proposed construction fllldude name addrass /phone/ contrac10ls' license number): 4. I plan to provide por1ions of the wor1<, but I have hired the foOowlng perron to coordinate, supeivtse and provide the major woric ~rdude name I address I phone I contraclors' license number): 5. I wtN provide some of the wor1<, but I have contracted (hired) the following persons to provide the wor1< Indicated (lndude name I address I phone I type of wor1<): _g PROPERlY OWNER SIGNATURE @AGENT DATE Is the ~plcant or future building occupant required to submit a business plan, acutely hazardous materials registration loon or risk management and prevenUon program under Sections 25505, 25533 or 25534 of the Prasley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the appicait or future buldng occupant reqlired to obCain a pennil from the air pollution conlrol dls1tict or air quality management disbict? □ Yes □ No Is lhe faclity t> be oonslructed wl1hi1 1,000 feel of ~e outer boundary of a school site? □ Yes □ No IF ~y OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE Of EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm lhat there is a construction lending agency for Jhe performance of Jhe work this penmit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lenders Address I oertlfythatl ha\'8 read the application lsCOfl'eCland 1hatthelnfonnationon lhe plans lsaa:urall!. I agreetooomply'IAthall Ci1)1ordlnances and State laws relating ID buBdlng cons1rudion. I hereby aulhori2e representative menooned property for ns,:ecoon pulJ))SeS. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CflY OF CARLSBAD AGAINST ALL LW!IUTIES, JU MAY N m'f WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: AA OSHA permit is • or oonsru:ooo of structures r;J"8r 3 slores In heght. EXPIRATION: Every pennit • of ~Is Code shaD expie by lmitalon and becare nul and 'IOid l lhe tuH,g or l',OfK authorized by such pemjl is not commenced wilhin 100days iom the date of sw, such pennl is sus~ or abandoned at any lirre ale' the v.ork is cormieiad b' a perioo of 100 days (Sedbn 100.4.4 Unifoon Buikflng Code). DATE Inspection List Permit#: CB154288 Type: COGEN PHOTO TAYLOR: ROOF MOUNT PV 10.07KW, 38 MODULES, NO PANEL UPGR Date __ Inspection Item Inspector Act Comments 02/23/2016 35 Photo Voltaic (PV) RI 02/23/2016 39 Final Electrical RI 02/22/2016 35 Photo Voltaic (PV) RI AM PLEASE 02/22/2016 35 Photo Voltaic (PV) AEK AP 02/22/2016 39 Final Electrical RI AM PLEASE 02/22/2016 39 Final Electrical AEK Fl Monday, February 22, 2016 Page 1 of 1 EsGil Corporation In (['artnersfiip witfi government for (Bui(aing Safety DATE: 01/05/ 16 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 15-4288 PROJECT ADDRESS: 2864 Via Conquistador SET: II ~LICANT ~ :_~~IS. D PLAN REVIEWER D FILE PROJECT NAME: GAYLENE TAYLOR 10,000 Watts Solar Photovoltaic System ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to : ~ Esgil Corporation staff did not advise the applicant that the plan check has been completed . D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted : -Telephone#: Date contacted: (b~ Fax #: Mail Telephone Fax In Person 0 REMARKS: By: Sergio Azuela EsGil Corporation 0 GA O EJ O PC E-mail: 12/29 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, Cali fornia 92 123 ♦ (858) 560-1468 ♦ Fax (858) 560-1 576 EsGil Corporation In <Partnersliip wit Ii q overnment for <Bui{tfing Safety DATE: 12/ 14/ 15 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 15-4288 PROJECT ADDRESS: 2864 Via Conquistador SET: I □ j.PPLICANT ~JURIS. □ PLAN REVIEWER □ FILE PROJECT NAME: GAYLENE TAYLOR 10,000 Watts Solar Photovoltaic System D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed . Person contacted: Amaya Salce Telephone#: 760-877-4038 /Date con;acted: 17,,f I tp-{by:~ ~Mail (/(elephone Fax In Person 0 REMARKS: By: Sergio Azuela EsGil Corporation □ GA □ EJ □ PC Fax #: E-mail: asalce@solarcity.com Enclosures: 12/08 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92 123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 City of Carlsbad 15-4288 12/14/15 GENERAL PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2864 Via Conquistador DATE PLAN RECEIVED BY ESGIL CORPORATION: 12/08 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: 15-4288 DATE REVIEW COMPLETED: 12/14/15 This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, co unty or city law. • Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning , Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? □ Yes D No City of Carlsbad 15-4288 i2/14/15 ELECTRICAL and ENERGY COMMENTS PLAN REVIEWER: Sergio Azuela ELECTRICAL (2013 CALIFORNIA ELECTRICAL CODE) • PLANS AND GENERAL INFORMATION 1. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code. 5536.1 ). 2. Parallel design is not approved. See Single Line Diagram on sheet PV 5. ♦ The following options are available: ♦ Provide the fusing. ♦ Extend the strings to the inverters. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. City of Carlsbad 15-4288 12/14/15 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Sergio Azuela PLAN CHECK NO.: 15-4288 DATE: 12/ 14/ 15 BUILDING ADDRESS: 2864 Via Conquistador BUILDING OCCUPANCY: BUILDING AREA Valuation PORTION ( Sq . Ft.) Multiplier Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance ..- Pian Check Fee by Ordinance ..- Type of Review: D Complete Review O Repetitive Fee ...,. Repeats • Based on hourly rate D Other EJ Hourly EsGil Fee Comments: 1 1/2 hours plan review. TYPE OF CONSTRUCTION: Reg. VALUE Mod. D Structural Only 1-----1-.5-11 Hrs. @ • $100.0 0_ ($) $1so.001 Sheet 1 of 1 macvalue.doc +