Loading...
HomeMy WebLinkAbout1549 REGATTA RD; ; CBR2023-4050; PermitBuilding Permit Finaled Residential Permit Print Date: 04/16/2025 Job Address : Permit Type: Parcel#: Valuation: • Occupancy Group: #of Dwelling Units: Bed rooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: 1549 REGATTA RD, CARLSBAD, CA 92011-4038 BLDG-Residential Work Class: 2150715100 Track#: $2,593.80 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Description: HESNDERSON: CREATE NEW BATHROOM Applicant: Property Owner: Alteration DOUG RANDALL 9880 N MAGNOLIA SANTEE, CA 92071-1901 (619) 933-4868 CO-OWNERS HENDERSON KEITH WAND HEATHER FEE BUILDING PLAN CHECK REMODEL-RESIDENTIAL-KITCHEN or BATH 1549 REGATTA RD CARLSBAD, CA 92011-4038 (713) 907-9590 SB1473 -GREEN BUILDING STATE STANDARDS FEE STRONG MOTION -RESIDENTIAL (SMIP) Total Fees: $647.55 Total Payments To Date: $647.55 Permit No: Status: {'Cityof Carlsbad CBR2023-4050 Closed -Fina led Applied: 08/24/2023 Issued: 07/25/2024 Finaled Close Out: 04/16/2025 Final Inspection: 03/25/2025 INSPECTOR: de Roggenbuke, Dirk Contractor: YOSEPH ZORA 5519 CLAIREMONT MESA BLVD, # 153 SAN DIEGO, CA 92117-2342 (619) 304-5858 Balance Due: AMOUNT $245.05 $401.00 $1.00 $0.50 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov { City of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION 8-1 Plan Check (r!,~2-D 23 :Y OS◊ Est. Value PC Deposit f,2.l.fS 05 Date ca I 2. '-f I 2 3 I I Job Address 1549 Regatta Rd Unit: APN: 2150715100 -----· CT/Project #: __________________ Lot #:. ____ Vear Built: _________ _ BRIEF DESCRIPTION OF WORK: Create New full bathroom inside footprint of existing dwelling □ New SF: Living SF, _____ Deck SF, ____ Patio SF, ____ Garage SF __ _ Is this to create an Accessory Dwelling Unit? O Y O N New Fireplace? O YON , if yes how many? ___ _ ~ Remodel: _____ SF of affected area Is the area a conversion or change of use? Cl) YO N D Pool/Spa: _____ SF Additional Gas or Electrical Features? ____________ _ □ Solar: ___ KW, ___ Modules, Mounted:0Roof OGround, Tilt: 0 YON, RMA: 0 YON, Battery:OYO> N, Panel Upgrade: Ov ON Electric Meter number: ------------- 0th er: APPLICANT (PRIMARY CONTACT) Name: Doug Randall / Permit Runner PROPERTY OWNER Name: Keith & Heather Hesnderson Address: 9825 Maine Ave. Address: 1549 Regatta Rd City: Lakeside State:_C_a __ Zip:92040 City: Carlsbad State:_c_a __ Zip: 92011 Phone: 619-933-4868 Phone: (713) 907-9590 Email: permits@permitrunner.net Email: ____________________ _ DESIGN PROFESSIONAL CONTRACTOR OF RECORD Name: Business Name: CALI BATH AND KITCHEN ------------------Address: Address: 5519 CLAIRMONT MESA BLVD #153 City: ________ State: ___ .Zip: ____ _ City: SAN DIEGO State:_c_a __ Zip: 921 17 Phone: _________________ _ Phone: (858) 215-2676 Email: _________________ _ Email: calibath@permitrunner.net Architect State License: ___________ _ CSLB License#: 1022034 Class: B -------- Carlsbad Business License# (Required): _______ _ APPLICANT CERTIFICATION: I certify that I have read the application and state that agree to comply with oil City ordinances and State laws relating to building construction. NAME (PRINT): _o_o_u_g_R_a_n_d_a_11 ____ _ SI 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov REV. 04122 THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING TH IS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: I herebyaffirm under penalty of perjury that lam licensed under provisions of Chapter 9(commencingwith Section l000)of Division 3 of the Business and Professions Code, and my license is in full force and effect. I a/so affirm under penalty of perjury one of the following declarations {CHOOSE ONE): D I have and wi ll maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit Is Issued. PolicyNo. _________________________________________ _ -OR- [!! I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: STATE COMPENSATION INSURANCE F Policy No. 9270311 Expiration Date: _21_1_212_4 ______________ _ -OR- D Certificate of Exemption: I certify that in the performance of the work for wh ich this permit is Issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of t he work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: ______________________ Lender's Address: _____________________ _ CONTRACTOR CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to developmen e been accurately show d labeled as well as all on-site grading/site preparation. All improvements existing on the property were completed in accordance with all regulations in exist ce a the time of their co r tion, unles otherwise noted. NAME (PRINT): Doug Randall Note: If the person signing above is an authorized agent for the contractor ro~e a (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). -OR- DI, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). -OR- DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: A 1D, D FORM 8·61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors./ understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is submitted or at the following Web site: http:Ilwww.leginfo.ca.gov/ ca law. h tml. OWNER CERTIFICATION: Th e applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan, Any potentially existing detail within these plans inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. NAME (PRINT): SIGN: __________ DATE: _____ _ Note: If the erson si nin above is an authorized a ent for the ro ert owner include form 8-62 si ned b owner. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov 2 REV, 04/22 PERMIT INSPECTION HISTORY for (CBR2023-4050) Permit Type: BLDG-Residential Application Date: 08/24/2023 Owner: CO-OWNERS HENDERSON KEITH W AND HEATHER Work Class: Alteration Issue Date: 07/25/2024 Subdivision: CARLSBAD TCT#93-09A OCEAN Status: Scheduled Date 03/19/2025 03/25/2025 Closed -Finaled Expiration Date: 09/15/2025 IVR Number: 51559 BLUFF Address: 1549 REGATTA RD CARLSBAD, CA 92011-4038 Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspection Inspection Checklist Item COMMENTS BLDG-Building Deficiency BLDG-27 Shower PanfTubs 275499-2025 Checklist Item COMMENTS BLDG-Building Deficiency BLDG-SW-Inspection Checklist Item 275500-2025 COMMENTS Are erosion control BMPs functioning properly? Are perimeter control BMPs maintained? Is the entrance stabilized to prevent tracking? Have sediments been tracked on to the street? Has trash/debris accumulated throughout the site? Are portable restrooms properly positioned? Do portable restrooms have secondary containment? 03/19/2025 BLDG-14 279162-2025 Frame/Steel/Bolting/We lding (Decks) Checklist Item COMMENTS Status Passed Dirk de Roggenbuke Partial Pass Dirk de Roggenbuke Passed Dirk de Roggenbuke BLDG-Building Deficiency 3/19/25 bedroom 4, framing for new widow ok 03/25/2025 BLDG-Final Inspection Checklist Item 279489-2025 COMMENTS BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Passed Dirk de Roggenbuke Passed Yes Complete Passed Yes Reinspection Incomplete Passed Yes Yes Yes Yes Yes Yes Yes Passed Yes Passed Yes Yes Yes Yes Yes Complete Complete Wednesday, April 16, 2025 Page 2 of 2 Building Permit Inspection History Finaled (cityof Carlsbad PERMIT INSPECTION HISTORY for (CBR2023-4050) Permit Type: BLDG-Residential Application Date: 08/24/2023 Owner: CO-OWNERS HENDERSON KEITH W AND HEATHER Work Class: Alteration Issue Date: 07/25/2024 Subdivision: CARLSBAD TCT#93-09A OCEAN BLUFF Status: Closed -Finaled Expiration Date: 09/15/2025 Address: 1549 REGATTA RD IVR Number: 51559 CARLSBAD, CA 92011-4038 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 01/27/2025 01/27/2025 BLDG-21 274598-2025 Passed Dirk de Roggenbuke Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-84 Rough 27 4599-2025 Passed Dirk de Roggenbuke Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 No Rough-Ducts-Dampers BLDG-SW-Inspection 274600-2025 Partial Pass Dirk de Roggenbuke Re inspection Incomplete Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 02/05/2025 02/05/2025 BLDG-16 lnsulatlon 275498-2025 Passed Dirk de Roggenbuke Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-17 Interior 275321-2025 Partial Pass Dirk de Roggenbuke Reinspection Incomplete Lath/Drywall Wednesday, April 16, 2025 Page 1 of 2 Transmittal Letter September S, 2023 City of Carlsbad Community Development Department -Building Division 1635 Faraday Ave. Carlsbad. CA 92008 Plan Review: Residential Remodel Address: 1549 Regatta Rd, Carlsbad CA Applicant Name: Doug Randall Applicant Email: permits@permitrunner.net COMPllANCE S.ERVICfS FIRST REVIEW City Pennit No: CBR2023-4050 True North No.: 23-018-821 True North Compliance Services, Inc. has completed the review of the following documents for the project referenced above on behalf of the City of Carlsbad. Our comments can be found on the attached list. I. Drawings: Hard Copy dated July 21, 2023, by Not provided. Attn: Permit Technician, the scope of work on the plans has been reviewed for coordination with the scope of work on the permit application. See below for information if the scope of work on plans differs from the permit application: Valuation: Scope of Work: Floor Area: See Notes Below Confirmed See Notes Below Notes: Valuation and floor area were not provided per the permit application Our comments follow on the attached list. Please call if you have any questions or if we can be of further assistance. Sincerely, True North Compliance Services Review By: Ali Al-Murshid -Plan Review Engineer Quality Review By: Ryan DeCastro -Plan Review Engineer True North Compliance Services,, Inc. Residential Remodel 1549 Regatta Rd September 5, 2023 City of Carlsbad-FIRST REVIEW City Permit No.: CBR2023-4050 True North No.: 23-018-821 Page2 Plan Review Comments HARD COPY -RESUBMITTAL INSTRUCTIONS: Please do not resubmit plans until all departments have completed their reviews. For status, please contact building@carlsbadca.gov Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). Corrected sets can be submitted as follows: Deliver THREE corrected sets of plans and TWO corrected calculations/reports directly to the City of Carlsbad Building Division, 1635 Faraday Ave., Carlsbad, CA 92008, (442) 339-27 19. The city will route the plans to True North, Planning and Land Development Engineering Departments (if applicable) for continued review. Note: If this project requires FIRE PREVENTION review, ensure that you follow their specific instructions for resubmittal review. The city will not route plans back to Dennis Grubb & Associates for continued Fire Prevention review. GENERAL INFORMATION: A. B. C. D. ..---The following comments are referred to the 2022 California Building, Mechanical, Plumbing, Electrical Codes, California Green Building Standards Code, and Energy Code (Le., 2021 me, UMC, UPC, and 2020 NEC, as amended by the State of California). There may be other comments generated by the Building Division and/or other City departments that will also require your attention and response. This attached list of comments, then, is only a portion of the plan review. Contact the City for other items. Respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which details, specification, or calculation shows the required information. Your complete and clear responses will expedite the re-check. Where applicable, be sure to include the architect and engineer's stamp and signature on all sheets of the drawings and on the coversheets of specifications and calculations per CBPC 5536.1 and CBPC 6735. This item will be verified prior to plan approval. OCCUPANCY & BUILDING SUMMARY: Occupancy Groups: Type of Construction: Sprinklers: Stories: Area of Work (sq. ft.): Provide this information VB No Provide this information Provide this information in sq. ft. ? Residential Remodel 1~49 Regatta Rd September 5, 2023 City of Carlsbad-FIRST REVIEW City Permit No.: CBR2023-4050 True North No.: 23-018-821 Page 4 / ✓ (4) /4) The net clear width shall be 20" minimum. Please consider accounting for the 2" window sashes on each side of the window. A5. Show location of all existing smoke and carbon monoxide alarms. a) Smoke alarms are required in every bedroom, area leading to these bedrooms and on every floor. CRC 314.3 b) Carbon monoxide alarm is required in all areas leading into the bedroom and on every floor. CRC R315.3 MECHANICAL COMMENTS: Ml. Show the location of the bathroom exhaust duct termination. Air ducts sh all exhaust 3'-0" from openings into the building and the property line. CMC 504.5 ELECTRICAL COMMENTS: El. In the bathroom, provi~ GFCI receptacle outlets within 3 feet of the sink basin's edge per CEC 2 10.52(D) and 210.8. E2. Provide at least one wall switched-controlled lighting outlet at the bathroom per CEC 210. 70(A). Show the location for light fixtures and light switches. ~ PLUMBING COMMENTS: [fj Pl. Provide the following water-conserving plumbing fixture flow rates on the plans: a) Water closet to be 1.28 gallons per flush maximum or dual flush. [CPC 411.2.] b) Residential lavatory faucet to be 1.2 gallons per minute, maximum. [CPC 407.2.2] c) Showerheads to be 1.8 gallons per minute, maximum. [CPC 408.2] GREEN BUILDING COMMENTS: GI. Provide the valuation of the project. Climate Action Plan requirements apply to all new structures, residential additions/remodels equal to or exceeding $60,000 in valuation, and commercial City of Carlsbad requires that all projects that qualify for CAP compliance will require a completed Climate Action Plan (CAP) Consistency Checklist (city form B-50) to be completed by the APPLICANT. a) For plans submitted to the City the following Climate Action Plan requirements apply, per Carlsbad ordinance: b) The applicant is to fill out the B-50 CAP Consistency Checklist. The scope of work and project valuation will determine which sections of the CAP are required. c) Plan examiners review the B-50 CAP Consistency Checklist for completion. For example: If new residential construction is the scope of work, CAP sections 2A, 3A, and 4A are required to be filled on the B-50 checklist. ENERGY COMPLIANCE COMMENTS: Tl. Please note the following on the plans: Residential Remodel 1S49 Regatta Rd September 5, 2023 City of Carlsbad-FIRST REVIEW City Pennit No.: CBR2023-4050 True North No.: 23-018-821 Page 3 ARCIDTECTURAL COMMENTS: Al . The name and signature of the _person who prepared the plans shall be included on each sheet of the plans. B&P Code 5536.1 ~- A2. On Sheet A0l, address the following comments: Revise building codes to reference 2022 instead of 201 9. I < ,.,.-4, ' ... , ~_. Ai ' I • ·( O,,, J ·!'" ·.t •• tf •· ._ 4 1, .''•• '-••. , •r"';,:-~ ·' 1 "J. ;• • ; .._ • .:.. •• ~ I ~i ••· ~---~ .. ,.. 1 • ! d •. • ... t ·,• • '·.•: . ... . b) Revise floor plan notes no 2, 3 and I 0, general green code notes no 12 and 13 and plumbing note no.3 to reference 2022 CGBSC instead of 2019. c) d) Specify the Occupancy Group to be R-3/U. Provide the Number of Stories ,,,, :J e) Provide the Floor Area (new, existing, total, etc.) in sq. ft. l.-, ,,....-· f) Provide the Designer's infonnation. 3. Provide site plan and dimension the distance of the exterior wall of the main dwelling to the property line. A4. Sheet A03: a) At new bathroom: i) ii) iii) Specify the shower doors to be 22" minimum. Shower door shall open so as to maintain a 22" minimum unobstructed opening for egress. [CPC 408.5] Specify the glass shower enclosure to be tempered per CRC R308.4. Provide 24" from the front of the water closet to near obstacle per CPC 402.5. At bedroom-4: i) Smoke alann is required in bedroom-4. CRC 314.3 t'J p~ t-; ~dDv -r-,~)~ ~ ii) Provide infonnation about new emergency escape window (type and height above floor) and ensure the following: :/(1) Openings shall have the bottom of the clear opening not greater than 44 incl:),es, measured from the floor. / ./ (2) The net clear opening shall be 5. 7 square feet minimum (grade floor openings may have a net clear opening of 5.0 square feet minimum). The net clear height shall be 24" minimum. eA$t, Residential Remodel , 1549 Regatta Rd September 5, 2023 City of Carlsbad-FIRST REVIEW City Pennit No.: CBR2023-4050 True North No.: 23-018-821 Page5 a) Note on plans: All lighting to be high efficacy. CEnergyC 150.0(k)l(A) ~ /h ~ ...... J Revise plan to show interior ]jghting fixtures at bedroom-4 that are not controlled by occupanCY.Jlt-~ vacancy sensors to be equipped with dimming controls. CEnergyC 150.0 (K)(2)(F) ~ c) Revise plan to show at least one _E:!Dlinaire in the bathroom to be controlled by a vacancy sensor. CEnergyC 150.0(k)2(E) ~ d) Revise plan to show exhaust fan and light fixture to be separately switched per CEnergyC l 50.0(k)(2)(G). T2. Specify neW'fenestrations (e.g. windows and doors) to have a maximum U-factor of 0.30 and a maximum SHGC of0.23. CEnergyC Table 150.1-A STRUCTURAL COMMENTS: SL. Clarify if the new window in Bedroom 4 is a new opening or if the window is being replaced, if opening is new please address the following: -7 4 ,e_ \,v '-"" j ~ J ~ w- a) Provide header size at new window in bedroom-4. -7 o i, p /qt, S b) ~lease share details about shear, wrl!s and explain wpether tl\e new opening in ~edroom-4 has any 1mpactonthem. ~ Ci:>41Y--C<.cJ-ot-t'.:. J.,e_t-,e.V-h, I ~-e '0~ $' f- c) Provide material specification for the construction material used. (lumber species and grade). f e. If you have any questions regarding the above comments, please contact Ryan DeCastro via email ryand@tncservices.~om or telephone (562) 733-8030. rEND1