Loading...
HomeMy WebLinkAbout2840 VIA CONQUISTADOR; ; CB991238; PermitCity of Carlsbad 04/12/1999 Residential Permit Permit No:CB991238 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: 03/31/1999 # Dwelling Units: Bedrooms: Project Title: Applicant: SHEA HOMES 200 Building Inspection Request Line (760) 438-3101 2840 VIA CONQUISTADOR CBAD RESDNTL Sub Type: SFD Status: 2225922000 Lot#: 84 Applied: $193,687.00 Construction Type: VN Entered By: 6 Reference #: CT93-04 1 Structure Type: SFD Issued: 3 Bathrooms: 2.5 Inspect Area: BENICIA-RANCHO CARRILLO-PHSE4 Orig PC#: PLAN 1, SFD 2203 SF.GAR 567 SF-VILLAGE Q Plan Check#: Owner: 10721 TREENA STREET SAN DIEGO CA 92131 619-549-3156 CONTINENTAL RANCH INC C/O CONTINENTAL HOMES 12636 HIGH BLUFF DR #300 SAN DIEGO CA 92130 ISSUED 03/11 /1999 JM Plan Approved: 04/12/1999 CB981009 990034 Total Fees: $15,272.19 Total Payments To Date: Balance Due: $15,272.19 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Inspector: m= $950.08 Reel. Water Con. Fee $0.00 $0.00 Meter Size $617.55 Add'I Reel. Water Con. Fee $0.00 $0.00 CFD Payoff Fee $4,485.49 ($49.40) PFF $3,525.10 $19.37 PFF (CFD Fund) $0.00 $0.00 License Tax $0.00 $0.00 License Tax (CFD Fund) $0.00 $0.00 Traffic Impact Fee $550.00 $0.00 Traffic Impact (CFO Fund) $0.00 $0.00 PLUMBING TOTAL $175.00 $0.00 ELECTRICAL TOT AL $60.00 $0.00 MECHANICAL TOTAL $59.00 $0.00 Housing Impact Fee $0.00 $0.00 Housing lnlieu Fee $0.00 $0.00 Master Drainage Fee: $0.00 $2,400.00 Sewer Fee: $2,480.00 D5/8 $0.00 TOTAL PERMIT FEES $15,272.1 9 FINAL APPROVAL Date: ·3 -c,0--00 Clearance: 3· \"l -ctz NOTICE: Please take NOTICE that approval of your project includes the 'Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exactions.· You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Cartsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired. 2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161 I , UNSCHEDULED BUILDING INSPECTION DATE 3-}7::fX) PERMIT# 19J2~'b INSPECTOR -DA~--- PLAN CHECK# ____ _ DESCRIPTION -----------~l.Q<-arl---,s.g<C.....~,___ ___ _ CODE DESCRIPTION ACT COMMENTS • . . City of Carlsbad Bldg Inspection Request For: 3/15/2000 . Permit# CB991238 Title: BENICIA-RANCHO CARRILLO-PHSE4 Description: PLAN 1, SFD 2203 SF,GAR 567 SF-VILLAGE Q Type: RESDNTL Sub Type: SFD Job Address: 2840 VIA CONQUISTADOR Suite: Lot 84 Location: OWNER CONTINENTAL RANCH INC Owner: SHEA HOMES LTD PARTNERSHIP Remarks: Total Time: CD Descri ption Act Comments 19 Final Structural _µ!J 29 Final Plumbing -- 39 Final Electrical -- 49 Final Mechanical -- Associated PCRs lnsgection Histor.y Date Description Act lnsp Comments 2/15/2000 39 Final Electrical AP DA EMR 12/29/1999 82 Drywall/Ext Lath/Gas Test AP DA 12/20/1999 16 Insulation AP DA 12/15/1999 84 Rough Combo AP DA 12/14/1999 84 Rough Combo NS DA 12/3/1999 13 Shear Panels/HD's AP DA 11/15/1999 15 Roof/Reroof AP DA 6/9/1999 11 Fig/Foundation/Piers AP DH Inspector Assignment: DA --- Phone: 6198439542 Inspector: '2fr: Requested By: RAY Entered By: CHRISTINE INC OR PORAT ED GEO TECHNICAL CONSULTANTS !~ GEOCON C 6960 FLANDERS DRIVE e SAN D~E;~~A~;~~~~l;~;~RV;~~~~58R~~;R;AX (619) 558-6159 • PROJECT NAME: PrN c w1 ,.. M, .rt , ]-,-1/ft " u $'-C '< , PROJECT No. s:E ~1 r , , -11 LOCATION: /,,,J ~/-,072, s,~ ,, j 1,~',1 DATE : ,"', 13.jc,Ja FOUNDATION LOCATION (if not entire building)-------------------------- PLAN FILE NO. PERMIT NOS : l ~--aq Of'!(,, t{)I r.:: q ''H7. 5'3 0 ADDITIONAL OBSERVATION REQUIRED FOUNDATION TYPE : ht 1fJ-?q /"t-4-"t 0 CONVENTIONAL J1rl?-I-ctq111q 1B' SUBSTANTIAL CONFORMANCE 0 POST-TENSIONED • PURPOSE OF OBSERVATION 0 Verify soil conditions exposed are similar to those anticipated l2l Verify footing excavations extend to minimum depth recommended in soil report 0 Verify foundation reinforcement complies with minimum recommended in soil report [2] Verify slab reinforcement, sand bedding and moisture barrier comply with minimum recommended in soil report 0 Verify footings have been extended to an appropriate bearing strata .. 0 Other -----'--------'-1 _ ____,...__ __ "--'-;--_..,....,_ ___________________________ _ • SOIL REPORT RECOMMENDATIONS BASED ON: 0 Expansion Condition / □ VERY LOW 0 LOW G-MEDIUM 0 HIGH 0 VERY HIGH [B Fill Geometry ------------------------------------- 0 Other : ----------------------------------------, • MINIMUM FOUNDATION RECOMMENDATIONS: Footing Depth: 0 12 Inches D 18 Inches ~Inches OTHER _____________ _ Footing Reinforcement: 0 No.4 T&B O 2-No.4 T&B !3'2-No.5 T&B D Post-Tensioned OTHER : _____ _ Interior Slab Reinforcement : D 6x6-10/10 D 6x6-6/6 [:] No.3@24Inches [!]~.3@181nches O Post-Tensioned Slab Bedding Material and Thickness : ----~------------Vapor Barrier : .V:L,_ _______ _ , Foundation Width : -~~-"'--------------------------------- • OBSERVATIONS: _p Substantial conformance with Soil Reports (see "Purpose of Observation") □ Substantial conformance with Foundation Plans. Identify : --------------------- 0 Other • COMMENTS: ---------------------------------- .. ' ,I I ' ,/\ICu Alt' r-.h1 1JJu?r4 1uq, ,.,( 3/;J11J . --~w . t--. NOTE • IT IS ASSUMED THAT All FOOTING EXCAVATIONS Will BE CLEANED OF LOOSE MA TE RIAL PRIOR TO PLACING CONCRETE AND THAT THE-jOIL MOISTURE CONTENT Will BE MAINTAINED I r/ ( ,- FIELD COPIES TO c GEOCON REPRESENTATIVE 03/17/00 FRI 11:35 FAX 760 929 8266 &e::-.ICH ldy of Carlsbad 2075 l.11 Palm•t Driv•, C..rl1b.iid Callfomla 92009 INSPECTION RECORD INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB CALL PRIOR TO 2:00 P.M. FOR NEXT WORKDAY INSPECTION ilJ002 JOB ADDRESS: ___ _ BUILDING INSPECTION: (760) 438-3101 01-\ ___________________ LOT NO./SUITE; ___ 0 __ ,--__ DATE 4¢/J{E OWNERS N"-ME: C8991238 2840 VIA CONQUIS TAOOR CSAO USE/OCCUPANCX BENICIA,RANCHO CARRILLO-PHSE4 PLAN 1, SFD 2203 SF.GAR 567 SF-VILLAGE O )NST. CONTRACTOR BUILDING OTHER RESDNTL SFD Lot#. 84 CONTINENTAL RANCH INC APPROVED TO COVER Type of Inspection Date Inspector NotH BUILD/NC I FOUNDATION ,. ,..,, (14' /l f /._ REINFORCED STEEL Df 'l I , f/·/. MASONRY □CROUT □ WALL DRAINS TILT PANEI.S POUR STftlPS COLUMN FOOTINGS SUBFRAME □ FLOOR 0 CEILING ROOF SHEATHING HS-99 -vtt- EXT. SHEAR PANELS ,?..--:.,-.ct~ n~ FRAME 1?-.-1 c::~9'f ,?,4- INSULATION '(",).-':l\-"{'f -o.l\ EXTERIOR LA TH ---.... ,..,.._ ,y-,.,/\_ INTERIOR LATH & DRYWALL ... ,~ ( ....... --- FINAL -"7,-,..,_N\ '").(l , PLUMB/NC I Jg SEWER AND BVCO ,..,,..vco _;,o h" /7// UNDERGROUND ')1WASTE .If WATER ..J f lUf I I ,(1/"/ ~' TOP OUT □WASTE □WATER .,, -!lo ~ TUB AND SHOWER PAN I ,1-1.;J 'I .., .. -><Q:GAS TEST □ GAS PIPING 1'1...~ 'C>A-.. □ WATER HEATER D SOLAR WATER FINAL ~"")-(!)(Q "'i'"}r+- ELECTRICAL -J J ~LECTRIC UNDERGROUND Jl{UFER 1//7/(n ~/11- ROUCH ELECTRIC WALLS -n ~ -•~ f')A ROUCH ELECTRIC CEILING j -___,_, t', ~ECTRIC SERVICE □ 'TEMPORARY I 11_-; C:-...-{"'ln ,;-..A, □ BONDING □POOL - FINAL ".2..-r,-mr ~t..,)r,--- MECHANICAL UNDERGROUND DUCTS & PIPING □ DUCT & PLEM.□ REF. PIPING ·,rJ ,~= ~.IL HEAT -AIR CONO. SYSTEMS V .., II r,' VENTILATING SYSTEMS FINAL .Ly-) /-U J 'JJ"r CALL FOR FINAL INSP€CTION WHEN Alu'.PPROPRU TE ITEMS ABOVE HAVE BEEN APPROVED FINAL Si1111 When Approprio_te Buildlng Dept. (lnspcctlonsl 438-3101 1""2..-1-1-.(Y ',)~ Fire Department 931-2121 , Plannins Oepatrrnent 436-1161 1'1-1'2.. 'Z. ,,v, VVE:7 Engineering Dept. (Inspections) 438-3691 ""-I <;-Qi> IQ~ Suildlns lnspe,:tors (7am-4pml 438-3550 ,_ A ' CMWD 438-2722 Ext 7153 ~-~.rr, I( , ..., V. ..; Wa~r lnspedions -438-3891 -'--) -REV 9/98 SEE BACK FOR SPECIAL NOTES