Loading...
HomeMy WebLinkAbout2390 VIA PELICANO; ; CB900700; Permit.. • f5/02/90 15: 27 Page 1 of 1 B U I L D I N G Job Address: 2390 VIA PELICANO Permit Type: SINGLE FAMILY DWELLING Parcel No : 215-571-29-00 Valuation: 145,299 P E R M I T Str: Permit No: CB900700 Project No: A9000811 Development No: DEV89063 Fl: Ste: Construction Type: NEW Occupancy Group: R3 Description: PLAN 2 PC : SF GARAGE Class Code: 90-290 2027 SF 439 PHASE 4' LOT 119 Status: Applied Apr/Issue Validated By: ISSUED 05/02/90 05/02/90 DC CONTRACTOR J.-D1 I ''1 FIELDSTONE 14 CORPORATE PLAZA NEWPORT BEACH CA 92660 Lie. C 402826 619-546-8081 *** Fees Required *** *** Fees Collected & Credits *** -------------------------------------------- Fees: Adjustments: Total Fees: Fee description 10,770.00 .00 10,770.00 Total Credits: Total Payments: Balance Due: Units Fee/Unit .00 250.00 10,520.00 Ext fee Data --------------------------------------------------------------------------- Building Permit Plan Check Strong Motion Fee Public Facilities Fee Enter 'Y' for La Costa Enter 'Y' for Bridge MFF TIF > > > > Enter Park-in-Lieu District#(9) > Growth Management Fee & Zone(99) > * BUILDING TOTAL Enter "Y" for Plumbing Issue Fee Each Plumbing Fixture Each Building Sewer Each Water Heater Each Gas Piping System Each Vacuum Breaker * PLUMBING TOTAL ) > > > ) > Enter 'Y' for Electric Issue Fee > Single Phase Per AMP > * ELECTRICAL TOTAL ($10 Minimum) Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts To 100,000 BTU> Each Metal Fireplace > Each Vent Fan Single Duct > Each Hood > Each Dryer Vent > * MECHANICAL TOTAL .ur .. Fl~,'APPROVAL INSP. ~DATE __ CLEARANCE rt01/[0 IJ 1713.00 4.00 310.00 15 .00 1.00 1.00 1.00 2.00 100,00 1.00 1.00 3.00 1. 00 1.00 c I OF CARLSBAD 2.50 6.50 2.50 2 .50 2.50 .25 9.00 6.50 4.50 6.50 4.50 2075 Las Palmas Dr., Carlsbad CA 92009 (619) 438-1161 801.00 521,00 10.00 5085,00 Y 670.00 Y 530.00 Y 1713.00 983.00 310.00 6 10623.00 7.50 Y 37 .50 6.50 2.50 2.50 5.00 62.00 5.00 Y 25.00 30,00 15.00 Y 9.00 6.50 13.50 6.50 4.50 55.00 PERMIT# CB900700 DESCRIPTION: PLAN 2 PC SF GARAGE CITY OF CARLSBAD INSPECTION REQUEST FOR 09/26/90 90-290 2027 SF 439 INSPECTOR AREA Mf PLANCK# CB900700 OCC GRP PHASE 4 LOT 119 TYPE: SFD JOB ADDRESS: 2390 VIA FELICANO APPLICANT: FIELDSTONE COMPANY CONTRACTOR: FIELDSTONE OWNER: REMARKS: T2/MH/DON SPECIAL INSTRUCT: TOTAL TIME: CD 19 29 39 49 LVL DESCRIPTION ST Final structural PL Final Plumbing EL Final Electrical ME Final Mechanical ------------------- CONSTR. TYPE NEW STR: FL: STE: ~:~::: ~1!~~:!~~l Q~ PHONE: ,.f\t;J.v INSPECTOR ~"'-1"---l~~+---------- ACT COMMENTS ~--- ***** INSPECTION HISTORY***** DATE 072090 072090 071890 071090 071090 071090 071090 071090 071090 071090 071090 070590 070590 062690 051490 051190 050990 050990 DESCRIPTION Interior Lath/Drywall Exterior Lath/Drywall Grout Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Rough/Ducts/Dampers Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Rough/Ducts/Dampers Gas/Test/Repairs Rough/Topout Roof/Reroof Ftg/Foundation/Piers Ftg/Foundation/Piers Sewer/Water Service Underground/Under Floor ACT AP AP AP co AP AP AP co co co AP AP AP AP AP NR AP AP INSP MP MP MP MP MP MP MP MP MP MP MP PY PY MP MP MP MP MP COMMENTS RET WALL STRAP UPPER KITCHEN VENT BLOCK 2X8 VERT. ABOVE ALCOVE REDHEAD PLATE LIVINGROOM PULL FAU DUCT OFF VENT DEPT: BUILDING FINAL BUILDING IN 5cTION ENGINEERING FIRE LANNIN:J U/M PLAN CHECK#: CB900700 PERMIT#: CB900700 PROJECT NAME: PLAN 2 PC 90-290 2027 SF 439 SF GARAGE PHASE 4 LOT 119 ADDRESS: 2390 VIA FELICANO CONTACT PERSON/PHONE#: SEWER DIST: LC WATER DIST: CA WATER DATE: 09/12/90 PERMIT TYPE: SFD INSPECTED /l / DATE /jf-/J~'/) / ===================================~=~~ ================================= BY: ----~-~IL-,:::_ ___ INSPECTED: 'd£:7/ I APPROVED__ DISAPPROVED _ INSPECTED BY: INSPECTED BY: DATE INSPECTED: DATE INSPECTED: APPROVED DISAPPROVED APPROVED DISAPPROVED ==================-====--==---===---===---=====-============================= COMMENTS: ~--..., FINL BUILDING INSPECTION DEPT: BUILDING 6GINEERING PLAN CHECK#: CB90~ IRE PLANNING PERMIT#: CB900700 ~ PROJECT NAME: PLAN 2 PC 90-290 2027 SF 43 SF GARAGE PHASE 4 LOT 119 ADDRESS: 2390 VIA FELICANO CONTACT PERSON/PHONE#: SEWER DIST: LC WATER DIST: CA U/M WATER DATE: 09/12/90 PERMIT TYPE: SFD [~~;;~TE~~--,~~~~::::::#==::::::::==7=:::::::::::=== INSPECTED DATE BY: __________ INSPECTED: ____ APPROVED DISAPPROVED INSPECTED BY: DATE INSPECTED: APPROVED DISAPPROVED ==============================-============================================== COMMENTS: FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING PLAN CHECK#: CB900700 PERMIT#: CB900700 FIRE PLANNING PROJECT NAME: PLAN 2 PC 90-290 2027 SF 439 SF GARAGE PHASE 4 LOT 119 ADDRESS: 2390 VIA PELICANO CONTACT PERSON/PHONE#: SEWER DIST: LC WATER DIST: CA WATER DATE: 09/12/90 PERMIT TYPE: SFD INSPECTED BY: DATE TP ~~ / INSPECTED: '1-1.Jl.-/-t:zo APPROVED L DISAPPROVED INSPECTED BY: INSPECTED BY: DATE INSPECTED: DATE INSPECTED : APPROVED DISAPPROVED APPROVED DISAPPROVED ========================-=====-===---=----==----=-----------===---===---==--- COMMENTS: S£P 1990 S\ AA RJS5 FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING E ) PLANNING U/M PLAN CHECK#: CB900700 PERMIT#: CB900700 PROJECT NAME: PLAN 2 PC 90-290 2027 SF 439 SF GARAGE PHASE 4 LOT 119 ADDRESS: 2390 VIA PELICANO CONTACT PERSON/PHONE#: SEWER DIST: LC WATER DIST: CA RECEIVED SEP t 4 1990 WATER DATE: 09/12/90 PERMIT TYPE: SFD ============================================================================= INSPEC~D DATE BY: . 6d ck----= INSPECTED: 9/2 '1/fo APPROVED ii--DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED ============================================================================= COMMENTS: FINAL BUILDING INSPECTION ~ DEPT: BUILDING ENGINEERING FIRE PLANNING U/M ~ PLAN CHECK#: CB900700 DATE: 09/12/90 PERMIT#: CB900700 PERMIT TYPE: SFD PROJECT NAME: PLAN 2 PC 90-290 2027 SF 439 SF GARAGE PHASE 4 LOT 119 ADDRESS: 2390 VIA FELICANO CONTACT PERSON/PHONE#: SEWER DIST: LC WATER DIST: CA ========================================================7 ================= INSPECTED ~ DATE BY: -----<'--"""-=-----INSPECTED:SEP. 1 81990 APPROVED __ DISAPPROVED _ INSPECTED BY: INSPECTED BY: DATE INSPECTED: DATE INSPECTED: APPROVED DISAPPROVED APPROVED DISAPPROVED ========.==c1rlllbifd"MunlcfpaTWater"""Dfstrlct -================================== COMMENTS· Engineering Departme1 ,t (619) 438-336 7 PCET-TENSICNIN'.; AND EIJJGATIOO OIARl' JOB NAME Alga Hills SCS&T 8912271 AODRF.SS 2390 Via Felicano DATE 06-13-90 UJr NUMBER 119 GAirn # 855520 BUill)IlC PERMIT CB-900-700 CALIBRATIOO DATE 01-25-90 PLAN FILE Plan 2 STRAND GAUGE ELJ)NGATIONl inches NUMBER READING INITIAL 'IDI'AL DESIGN NOI'ES 1 6860 1-5/8 1-5/8 2 6860 1-5/8 1-5/8 3 6860 2-3/8 2-1/8 4 6860 2-3/4 2-3/4 5 6860 2-3/4 2-3/4 6 6860 2-3/4 2-3/4 7 6860 2-7/8 2-3/4 8 6860 2-3/4' 2-3/4 9 6860 3-1/8 3 10 6860 2-3/4 2-3/4 11 6860 2-3/4 2-3/4 12 6860 3/4 3/4 13 6860 3-3/4 3-3/4 14 6860 3-3/4 3-3/4 15 6860 3-3/4 3-3/4 16 6860 4-1/4 4-1/8 17 6860 4-1/4 4-1/8 18 6860 3 3 19 6860 2-1/2 2-1/2 20 6860 2-1/2 2-1/2 S OUTHERN CALIFORNIA SOIL A NO TESTING, I NC. 62B0 RIVERDALE STREET. P .O. BOX 20627, SAN DIEGO, CALIFORNIA 921 20 (S 1 9 ) 2B0-432 1 67B ENTERPRISE STREET. ESCONDIDO, CALIFORNIA 92025 (S 19) 746-4 544 REPORT CF COMPRESSION TESTS FILE NUMBER · 8912271 □ATE' May 22, 1990 ASTM (C39) Qt CONCRETE JOB. Al ga Hills A DDRESS 2390 Via Pe licano OWNER : ARCHITECT· Ro bert Bowlus Associates ENGINEER · CONTRAC70R Fieldstone/Ben F. Smith, Inc. L□cAT10N IN sTRucTu RE • s1 ab-on-grade, Lot # 119 CEMENT Type I I Pozzolith 322N ADMIXTURE· SANO ROCK So rrento Ready Mix Sorr ento Ready Mix Mix No oR PR0PoRT10Ns: SS0-001615 sack TIME IN MIXER, MINUTES: 46 SLUMP, INCHES 5 FABRICATED BY . RG/SCS& T Tested bv: DJ TRUCK NO: 91 LABORATORY NO: MARK· B DATE MADE DATE RECEIVED DATE TESTED DIAMETER, INCH ES AREA. SQ. INCHES MAXIMUM LOAD, LBS COMPRESSIVE STR , PSI · AGE TESTED, DAY S REQ "O PSI AT 28 D AYS UNIT WT/CU FT (PLASTIC]: 9145 5-15-90 5-16-90 5-22-90 6.00 28.27 59,000 2,090 7 2,500 D ISTRIBU T ION. (3) Ben F. Smith , In c. (1) City of Carlsbad (1) Sorrento Ready Mix (1) JEM I II 91 46 6-12-90 97,250 3,440 28 D MORTM R 0 GROUT 0 GUNITE D Permit #CB -900-700 TICKET NO· 64671 9147 Discarded L_.. SOUTHERN CALIFORNIA SOIL ANC TESTING, INC. REVIEWED BY: ~~tdL-- Michael B. Whee l er, R.C.E. #45358