Loading...
HomeMy WebLinkAbout1376 CASSINS ST; ; CBR2021-3370; PermitBuilding Permit Finaled Residential Permit Print Date: 04/22/2025 Job Address: 1376 CASSINS ST, CARLSBAD, CA 92011-4856 Permit Type: Parcel#: Valuation: BLDG-Residential 2156914600 $22,371.31 Occupancy Group: #of Dwelling Units: 1 Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: Work Class: Track#: Lot#: Project#: Plan#: Construction Type: Orig. Plan Check #: Plan Check#: Description: 1376 CASSINS;NEW ADU (481 SF) INTERIOR CONVERSION Property Owner: Second Dwelling Unit RYAN-LANDON ALISON P TRUST 09-17-96 1376 CASSI NS ST CARLSBAD, CA 92011-4856 FEE BUILDING PLAN CHECK BUILDING PLAN REVIEW-MINOR PROJECTS (LDE) BUILDING PLAN REVIEW-MINOR PROJECTS (PLN) CERTIFICATE OF OCCUPANCY GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION REMODEL-RESIDENTIAL-OTHER SB1473 -GREEN BUILDING STATE STANDARDS FEE STRONG MOTION -RESIDENTIAL (SMIP) Total Fees: $1,722.21 Total Payments To Date: $1,722.21 Permit No: Status: Applied: Issued: C cityof Carlsbad CBR2021-3370 Closed -Expired 11/10/2021 02/28/2022 Finaled Close Out: Final Inspection: INSPECTOR: de Roggenbuke, Dirk Balance Due: AMOUNT $755.30 $194.00 $98.00 $15.00 $175.00 $481.00 $1.00 $2.91 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. . . EXfirid Befure-AVttvf ln1>• tJO plans Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov ( City of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Check t!6'<2.o~I ... 33 70 Est. Value d ~ I; 5'2.CJ'. ;o PC Deposit If 75r• 3 0 Date // -IO -Z. 02.. I Job Address 1376 Cassins Street Unit: APN: 215-691-46 ----~ CT/Project #:_1_3_1_4_2 ______________ Lot #: 74 Year Built: _1_9_9_6 ______ _ BRIEF DESCRIPTION OF WORK: Create an ADU with disability accommodations for a current household resident. Convert existing bedroom, bathroom, and garage space to the new ADU. 0 New SF : Living SF, ____ Deck SF,. ___ Patio SF, ____ Garage SF __ _ Is this to create an Accessory Dwelling Unit? O Y O N New Fireplace? O YO N, if yes how many? ___ _ @1 Remodel:_4....;;.8--'-1 ___ SF of affected area Is the area a conversion or change of use? O YO N □ Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _ 0 Solar: ___ KW, ___ Modules, Mounted:ORoof O Ground, Tilt: 0 YON, RMA: 0 YO N, Battery:OYC N, Panel Upgrade:OYCN Other: PRIMARY APPLICANT Name: Mark Landon Address: 1376 Cassins Street City: Carlsbad State: CA Zip: 92011 Phone: (760} 931-1448 Email: MyDumpsterFile@gmail.com DESIGN PROFESSIONAL Name: Matt Deskin Address: 1752 Cottonwood Dr City: Vista State: CA Zip: 92081 Phone: (760) 427-1505 Email: mdeskin@att.net PROPERTY OWNER Name:Alison P. Ryan-Landon Trust Address: 1376 Cassins Street City: Carlsbad State: CA Zip:_9_2_0_11 __ _ Phone: (760) 822-0687 Email: AlisonRyanLandon@gmail.com CONTRACTOR OF RECORD Business Name: ________________ _ Address: _________________ _ City: _______ State: ___ Zip:. ______ _ Phone: -------------------Em a i I:. __________________ _ Architect State License: ___________ _ CSLB License #: ______ Class: ______ _ Carlsbad Business License # (Required): _______ _ APPLICANT CERT/FICA T/ON: I certify that I have read the application and state th:o=t the ab information is c agree to comply with all City ordinances and State laws relating ta building construction. NAME (PRINT): Mark Landon SIGN: ~---~U\TE: 11/05/2021 ect and that the information of the plans is accurate. I 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov REV. 10121 THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: lherebyaffirmunderpenaltyofperjurythatlamlicensedunderprovisionsofChapter9(commencingwithSection7000)ofDivision3 of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the following declarations (CHOOSE ONE): 01 have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. PolicyNo. ____________________________________________ _ -OR- DI have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name:-------------------------• Policy No. _____________________________ Expiration Date: ________________ _ -OR- O Certificate of Exempt ion: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of california. WARNING: Failure to secure workers compensation coverage Is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for In Section 3706 of the labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). lender's Name: _______________________ ,lender's Address: _______________________ _ CONTRACTOR CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans Inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. NAME (PRINT): Note: If the person signing above is an authorized agent for the contractor (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: liJ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). -OR- ~I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). -OR- DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: AND, liJ FORM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors./ understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is submitted or at the following Web site: http: I I www.leginfo.ca.gov/ cal aw. html. OWNER CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All improvements existing on the property were completed in accordance with all regulations in existence the time of their construction, unless otherwise noted. NAME (PRINT}: Alison P. Ryan-Landon Note: If the erson sl nln above is an authorized a ent for the 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 2 owner. Email: Building@carlsbadca.gov REV.10/2 ( City of Carlsbad OWNER-BUILDER ACKNOWLEDGEMENT FORM B-61 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov OWNER-BUILDER ACKNOWLEDGMENT FORM Pursuant to State of California Health and Safety Code Section 19825-19829 To: Property Owner An application for construction permit(s) has been submitted in your name listing you as the owner-builder of the property located at: Site Address 1376 Cassins Street, Carlsbad, CA 92011 The City of Carlsbad ("City") is providing you with this Owner-Builder Acknowledgment and Verification form to inform you of the responsibilities and the possible risks associated with typical construction activities issued in your name as the Owner-Builder. The City will not issue a construction permit until you have read and initialed your understanding of each provision in the Property Owner Acknowledgment section below and sign the form. An agent of the owner cannot execute this notice unless you, the property owner, complete the Owner's Authorized Agent form and it is accepted by the City of Carlsbad. INSTRUCTIONS: Please read and initial each statement below to acknowledge your understanding and verification of this information by signature at the bottom of the form. These are very important construction related acknowledgments designed to inform the property owner of his/her obligations related to the requested permit activities. I. ~I understand a frequent practice of unlicensed contractors is to have the property owner obtain an "Owner· Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed contractor and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of II. Ill. IV. V. te limits of my insurance coverage for injuries to workers on my property. ~I understand building permits are not required to be signed by property owners unless they are responsible ~or the construction and are not hiring a licensed contractor to assume this responsibility. ~understand as an "Owner-Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own. A -I understand contractors are required by law to be licensed and bonded in California and to list their license ~ers on permits and contracts. ~nderstand if I employ or otherwise engage any persons, other than California licensed contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. 1 REV. 08/20 VI. k 1 understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. VII._ ~ "'-t-understand under California Contractors' State License Law, an Owner-Builder who builds single-family ~ntial structures cannot legally build them with the intent to offer t hem for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building cont ractor. VIII. IX. X. XI. ~~ / I understand as an Owner-Builder if I sell t he property for which this permit is issued, I may be held liable ~y financial or personal injuries sustained by any subsequent owner(s) which result from any latent rnstruct ion defects in the workmanship or mat erials. ~ I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' St ate License Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed cont ractors. ~I am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the following address: (1,, fo Ca(frh s if--Ct:t---lth~ d Cit q '2..o l/ ~I agree t hat, as the party legally and fi na:Cially responsible for this proposed construction activity, I will abide bl(_ ~I applicable laws and requirements that govern Ow ner-Builders as well as employers. XII. ~ agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractor's State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner- Builder and wish to hire contractors, you will be responsible for verifying whether or not those contractors are properly licensed and the status of their workers' compensation coverage. Before a building permit can be issued, this form must be completed, signed by the property owner and returned to the City of Carlsbad Building Division. I declare under penalty af perjury that I have read and understand all af the information provided on this form ond that my responses, including my authority to sign this form, is true and correct. I om aware that I have the option to consult with legal counsel prior to signing this form, ond I have either (1) consulted with /ego/ counsel prior to signing this form or (2) have waived this right in signing this form without the advice of legal counsel. ,;P~rSign,Me Alison P. Ryan-Landon Trust Property Owner Name (PRINT) 11/05/102 I Date 2 REV. 08/20 ~ ~ Cicyof Carlsbad OWNERS AUTHORIZED AGENT FORM 8-62 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov OWNER'S AUTHORIZED AGENT FORM Only a property owner, contractor or their authorized agent may submit plans and applications for building permits. To authorize a third-party agent to sign for a building permit, the owner's third party agent must bring this signed form, which identifies the agent and the owner who s/he is representing, and for what jobs s/he may obtain permits. The form must be completed in its entirety to be accepted by the City for each separate permit application. Note: The following Owner's Authorized Agent form is required to be completed by the property owner only when designating an agent to apply for a construction permit on his/her behalf. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Property Owner Acknowledgement, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner-Builder Permit for my project. Scope of Construction Project (or Description of Work): Conver+ e.x,Jt,'y b eJ roo/v\f bcih (T)O tn, Qh cl 9ar4,~e fo V\evv A1)U. ProjectlocationorAddress: l"$-7b Cq{£1\d J}, Cg,v--l..fh4.ef CA q2..Dl{ 7 Name of Authorized Agent: --~l/Y)~(;l_r_k __ L~u_Vl~i_C>_(\ ____ Tel No. (7 ~ 6) q ~{ ~, lflt J Address of Authorized Agent: ___ ~l~>-7~b __ C_a_f'_'J_, h_J __ J_t ___________ _ Ccv--lJ /e,u_cf / CA-q 2-o l I • I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Property Owner's Signature: ---1-,b!:l ___ :::::...._c:::::::=:::=--------------Date: 1 PERMIT INSPECTION HISTORY for (CBR2021-3370) Permit Type: BLDG-Residential Application Date: 11/10/2021 Owner: TRUST RYAN-LANDON ALISON P TRUST 09-17-96 Work Class: Second Dwelling Unit Issue Date: 02/28/2022 Subdivision: CARLSBAD TCT#90-36 UNIT#02 Status: Closed -Finaled Expiration Date: 02/10/2025 Address: 1376 CASSINS ST CARLSBAD, CA 92011-4856 Scheduled Date IVR Number: Actual Inspection Type Start Date Inspection No. Checklist Item Are erosion control BMPs functioning properly? Are perimeter control BMPs maintained? Is the entrance stabilized to prevent tracking? Have sediments been tracked on to the street? Has trash/debris accumulated throughout the site? Are portable restrooms properly positioned? Do portable restrooms have secondary containment? COMMENTS Tuesday, April 22, 2025 36974 Inspection Primary Inspector Reinspection Inspection Status Passed Yes Yes Yes Yes Yes Yes Yes Page 3 of 3 PERMIT INSPECTION HISTORY for (CBR2021-3370) Permit Type: BLDG-Residential Application Date: 11/10/2021 Owner: TRUST RYAN-LANDON ALISON P TRUST 09-17-96 Work Class: Second Dwelling Unit Issue Date: 02/28/2022 Subdivision: CARLSBAD TCT#90-36 UNIT#02 Status: Closed -Finaled Expiration Date: 02/10/2025 IVR Number: 36974 Address: 1376 CASSINS ST CARLSBAD, CA 92011-4856 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Date Start Date Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers Status COMMENTS 12/06/2023 12/06/2023 BLDG-44 232781-2023 Failed Dirk de Roggenbuke 02/28/2024 02/28/2024 05/24/2024 05/24/2024 08/12/2024 08/12/2024 Tuesday, April 22, 2025 Rough/Ducts/Dampers Checklist Item BLDG-Building Deficiency COMMENTS 12/06/23 stove vent. proper flashing to seal roof opening needed. Mesh and black draft damper needed BLDG-16 Insulation 240788-2024 Passed Dirk de Roggenbuke Checklist Item COMMENTS BLDG-Building Deficiency BLDG-17 Interior 240501-2024 Passed Dirk de Roggenbuke Lath/Drywall Checklist Item COMMENTS BLDG-Building Deficiency BLDG-27 Shower 249745-2024 Failed Dirk de Roggenbuke Pan/Tubs Checklist Item COMMENTS BLDG-Building Deficiency 5/24/24 shower pan lining shall be pitched at 1/4" per foot per CPC 408.7 BLDG-27 Shower 257 489-2024 Passed Dirk de Roggenbuke Pan/Tubs Checklist Item COMMENTS BLDG-Building Deficiency 5/24/24 shower pan lining shall be pitched at 1/4" per foot per CPC 408.7 8/12/24 shower pan hot mop ok BLDG-SW-Inspection 257675-2024 Partial Pass Dirk de Roggenbuke Reinspection Inspection Passed Yes Yes Yes Yes Yes Reinspectlon Incomplete Passed No Complete Passed Yes Complete Passed Yes Reinspection Incomplete Passed No Complete Passed Yes Re inspection Incomplete Page 2 of 3 Building Permit Inspection History Finaled {cityof Carlsbad PERMIT INSPECTION HISTORY for (CBR2021-3370) Permit Type: BLDG-Residential Application Date: 11/10/2021 Owner: TRUST RYAN-LANDON ALISON P TRUST 09-17-96 Work Class: Second Dwelling Unit Issue Date: 02/28/2022 Subdivision: CARLSBAD TCT#90-36 UNIT#02 Status: Closed -Finaled Expiration Date: 02/10/2025 Address: 1376 CASSINS ST CARLSBAD, CA 92011-4856 IVR Number: 36974 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 06/21/2023 06/21/2023 BLDG-25 Water 214682-2023 Passed Dirk de Roggenbuke Complete HeaterNents Checklist Item COMMENTS Passed Yes BLDG-Building Deficiency NOTES Created By Angie Teanio TEXT Created Date 08/23/2023 08/23/2023 08/25/2023 08/25/2023 10/12/2023 10/12/2023 Tuesday, April 22, 2025 760-317-7117 Mark// Please call in advance. 06/19/2023 Disabled homeowner needs time to open the garage door. BLDG-Final Inspection 214683-2023 Cancelled Dirk de Roggenbuke Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final NOTES Created By Angie Teanio COMMENTS TEXT 760-317-7117 Mark// Please call in advance. Disabled homeowner needs time to open the garage door. BLDG-21 221705-2023 Passed Dirk de Roggenbuke Underground/Underflo or Plumbing Checklist Item COMMENTS BLDG-Building Deficiency BLDG-11 221988-2023 Passed Dirk de Roggenbuke Foundation/Ftg/Piers (Rebar) Checklist Item COMMENTS BLDG-Building Deficiency 8/25/23 foundation rebar, vapor barrier, pipes wrapped.Epoxy anchors. Special inspector report noted BLDG-84 Rough 226946-2023 Passed Dirk de Roggenbuke Combo(14,24,34,44) Relnspectlon Incomplete Passed No No No No No Created Date 06/19/2023 Passed Yes Passed Yes Complete Complete Complete Page 1 of 3 DATE: February 11, 2022 JURISDICTION: Carlsbad • lW INT ERWEST A SAFEbulll COMPANY ) □ APPLICANT □ JURIS. PLAN CHECK#.: CB-CBR2021-3370.rcl, Approved ____ SET: II PROJECT ADDRESS: 1376 Cassins Street PROJECT NAME: Convert Existing Bedroom, Bathroom, and Garage space to new ADU ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Mark Landon ~ lnterwest staff did not advise the applicant that the plan check has been completed. D lnterwest staff did advise the applicant that the plan check has been completed. Person contacted : Telephone#: Date contacted: Mail Telephone 0 REMARKS: By: Abe Doliente lnterwest (by: Email: Fax In Person Enclosures: 2/4/22 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92 123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: November 29, 2021 JURISDICTION: Carlsbad • lW INTERWEST A. SAfEb\llll COMPAHV PLAN CHECK#.: CB-CBR2021-3370 PROJECT ADDRESS: 1376 Cassins Street SET: I □ APPLICANT □ JURIS. PROJECT NAME: Convert Existing Bedroom, Bathroom, and Garage space to new ADU D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Mark Landon D lnterwest staff did not advise the applicant that the plan check has been completed. ~ lnterwest staff did advise the applicant that the plan check has been completed. Person contacted : Mark Landon Telephone#: 760-931 -1448 Date contacted: Mail Telephone 0 REMARKS: By: Abe Doliente lnterwest (by: Email: MyDumpsterFile@gmail.com Fax In Person Enclosures: 11/15/21 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CB-CBR2021-3370 November 29, 2021 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CB-CBR2021-3370 JURISDICTION: Carlsbad PROJECT ADDRESS: 1376 Cassins Street FLOOR AREA: Rem odel -48 1 SF REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: November 29, 2021 FOREWORD (PLEASE READ): STORIES: 2 HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 11/15/21 PLAN REVIEWER: Abe Doliente This plan review is limited to the technical requirements contained in the California Residential Code, California Building Code, California Plumbing Code, California Mechanical Code, California I Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2019 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2019 CRC, 2019 CBC, 2019 CPC, 2019 CMG and 2019 CEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2019 California Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CB-CBR2021-3370 November 29, 2021 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City Planning, Engineering and Fire Departments until review by lnterwest is complete. PLANS 1. Provide item-by-item responses on an 8-1/2-inch by 11-inch sheet(s) clearly and specifically indicating where and how each correction item has been addressed (vague responses, such as "Done" or "See plans," are unacceptable) 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Signatures on the final sets of plans will be verified before they are aplproved. 3. Plans shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations. (California Business and Professions Code). Signatures on the final sets of plans will be verified before they are approved. FIRE PROTECTION 4. Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. 5. Show locations of permanently wired smoke alarms at the ADU, per Section R314: 6. Also, note on the plans that existing smoke alarms and carbon monoxide alarms at the existing house will be field verified by the City Building lnspewctor. Carlsbad CB-CBR2021-3370 November 29, 2021 GENERAL RESIDENTIAL REQUIREMENTS 7. Clearly show on the floor plans the limits of the proposed ADU. 8. Wall assemblies separating main house and the attached accessory unit shall be of one-hour fire resistive construction. Provide details of the assemblies. Section R302 .3. Such wall assemblies shall extend to the underside of the roof sheathing, where applicable. Exceptions: a) A fire-resistance rating of ½-hour shall be permitted in buildings equipped throughout with an automatic sprinkler system installed in accordance with NFPA 13. b) Wall assemblies need not extend through attic spaces when the ceiling is protected by not less than ¾-inch Type X gypsum board and an attic draft stop constructed as specified in Section R302.12.1 is provided above and along the wall assembly separating the dwellings. The structural framing supporting the ceiling shall also be protected by not less than ½ -inch gypsum board or equivalent. 9. Floor assemblies separating the main house and the attached accessory unit shall be of one-hour fire resistive construction (½-hour if the building has an automatic sprinkler system). Provide details of the assemblies. Section R302.3. Such assemblies shall extend to and be tight to the exterior wall, where applicable. 10. The supporting construction of fire-rated floor assemblies shall have an equal or greater fire-rating. Section R302.3.1. 11 . Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor-- ceilings and roof-ceilings shall be protected as required in CRC Section R302.4." 12. Walls and floors separating the main house and the attached accessory unit shall have a sound transmission class (STC) of not less than 50. Additionally, floors must have an impact insulation class (IIC) rating of not less than 50. CBC Section 1207. Show the location of and provide details of the listed wall and floor/ceiling assemblies and indicate the listing agency and listing number for the tested ratings. ROOFS 13. Show the required ventilation for attics (or enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters). The minimum vent area is 1 /150 of attic area ( or 1 /300 of attic area if at least 40% (but not more than 50%) of the required vent is located no more than 3' below the ridge) and remaining vents located at the lower third of the of the attic space. Show on the plans the area required and area provided. Section R806.2. 14. Where eave vents are installed, insulation shall not block the free flow of air. A minimum of 1" of air space shall be provided between the insulation and the roof sheathing. To accommodate the thickness of insulation plus the required 1" ., Carlsbad CB-CBR2021-3370 November 29, 2021 clearance, member sizes may have to be increased for rafter-ceiling joists. Section R806.3. 15. Note on the plans: "Attic ventilation openings shall be covered with corrosion-resistant metal mesh with 1/16" minimum to¼" maximum openings. Section R806.1. 16. Show location of attic access with a minimum size of 22"x30", unless the maximum vertical headroom height in the attic is less than 30". Access must be provided to each separated attic area (if over 30 sq. ft.), shall be located in a hallway or other readily accessible location and 30" headroom clearance is required above the opening. Section R807.1. FOUNDATION/STRUCTURAL REQUIREMENTS 17. The following locations shall require the use pressure-preservative treated wood (Section R317.1): a) Wood joists or the bottom of a wood structural floor when closer than 18" (or wood girders when closer than 12") to exposed ground. b) All sill plates that rest on concrete or masonry exterior walls and are less than 8" above exposed ground. c) Sills and sleepers on a concrete or masonry slab that is in direct contact with the ground (unless separated from such slab by an impervious moisture barrier). d) The ends of wood girders entering exterior masonry or concrete walls having clearances of less than ½" on tops, sides and ends. e) Wood siding, sheathing and wall framing on the exterior of a building having a clearance of less than 6" from the ground. 18. Show all the shear walls, their lengths and hold downs on the plans. 19. Clarify the grid lines on the plans. Structural calculations used A, B, C, and D, but the plans show A, B,, 1, and 2. 20. The plans indicate that special inspection will be provided. Please complete the attached City special Inspection form. for the following work. (CBC Chapter 17 and Section 107.2) ELECTRICAL 21 . An ADU may have a separate utility service installed, or sub fed via existing service with adequate capacity. ADU's require electrical load calculations per CEC 220.83 to justify existing electrical service size is adequate. PLUMBING Carlsbad CB-CBR2021-3370 November 29, 2021 22. An instantaneous water heater is shown on the plans. Please include a gas pipe sizing design (isometric or pipe layout) for all gas loads. a) The gas pipe sizing for a tank type water heater shall be based upon a minimum 199,000 Btu gas input rating. Energy Standards 150.0(n). ENERGY CONSERVATION 23. Revise the energy calculations to show 2 stories instead of 1 story. 24. Include on the Title Sheet of the plans the following statement: "Compliance with the documentation requirements of the 2019 Energy Efficiency Standards is necessary for this project. Registered, signed, and dated copies of the appropriate CF1 R, CF2R, and CF3R forms shall be made available at necessary intervals for Building Inspector review. Final completed forms will be available for the building owner." 25. When replacing or modifying the mechanical system: If applicable. o If more than 40' of new ductwork is installed in unconditioned space, HERS inspection is required for both existing and new duct sealing. o Replacement of mechanical equipment (air handler, condensing unit of an air conditioner or heat pump, cooling or heating coil, or the furnace heat exchanger) requires HERS inspection. o Note: The CF1 R-AL T-HVAC form may be submitted at the final inspection, it is not required at initial plan submittal. MISCELLANEOUS 26. Revise note under General Notes on sheet 1 to show 2019 CRC instead of 2016. 27. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 28. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake Drive, Suite 208, San Diego , California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Error! Reference source not found. at lnterwest. Thank you. Carlsbad CB-CBR2021-3370 November 29, 2021 (_ City of Carlsbad SPECIAL INSPECTION AGREEMENT B-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov In accordance with Chapter 17 of the Callfornla Bulldfng Code the following must be completed when work being performed requires special Inspection, structural observation and construction material testing. Project/Permit: C t ~ 2 O 1-\ -'~ 1 O Project Address· I 3 7 ~ C A. > J l"l; S .f. A. ,.T}!IS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder 'Jll· (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please print) A \ fJo O P. I< VW) -L Ct '\ J. () " (Fnl) (M.11 T (~ .. , MailingAddress· \:17G Cu SH'nS St, c,v-\JbcicA C,\ qi..o\\-~5" Email· Vny<l·"'b~J:\er::b\e G 8~C\{LlO'!h Phone· (7C,o)3'l1-1l(J I am: ~roperty Owner □Property Owner's Agent of Record □Architect of Record □Engineer of Record State of California Registration Numbe • Expiration Date: _______ _ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise lo comply with the City of Carlsbad requirements for special inspections, structural observations, construction ma rials testing and off-site fabrication of building components. as prescribed in the statement of special Inspections noted on e approved pla sand. as required by the California Building Code. Signatur • Date: DI -2-J-Z.0 2. 1.- B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC. Ch 17, Section 1706). This section must be completed by the contractor I builder I owner-builder. Contractor's Company Name: A I, 's:o O f, f-yM-LC\"'J O I'\ Please check a you are Owner-Bu~der~ Name: (Please print) AltL:> O p, Rytiu,,.-l.-.tl Y\JD/) (F"") {Ml) f'A -• {LUI) 6 Mailing Address: I 3 7 b caJ f (hJ .f}, u.t.,. li bet, C{ l8 q 2.. c) l(-48 5 I Email: myd"'me-'\-fc+'ne {) 'h-st:\rl , c.ovn Phone· (;J 6--o) ~I 7-7(11 State of California Contractor's License Number: __________ Expiration Date: _______ _ • I acknowledge and, am aware, of special requirements contained In the statement of special inspections noted on the approved plans: • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution or the reports; and • I certify that I wil have a qualified person within our (the contractor's) organization to exercise such control. • t w111 argy/de a Qaafreaort11eu,,1n compliance wfth csc section 170:f.1,2 prior to requesting final inspection. Signature·~----;--==¥'!.---=------=-------------D,ate: B45 Page 1 of 1 Rev. 08/11 civ il e nginee ring structural des i gn land surveying STRUCTURAL CALCULATIONS REMODEL CASSINS 1376 Cassins St. Carlsbad, CA 92011 Job No: 21-637 January 18, 2022 CBR2021-3370 1376 CASSINS ST t:\ > 1---0 1376 CASSINS;NEW ADU (481 SF) INTERIOR CONVERSION 27315 Valley Center Road -Valley Center, CA Email: wynneng@wynnengineering.com -Los. 2156914600 2/1/2022 CBR2021-3370 JOB. WYNN ENGINEERING INC. 27315 Valley Center Road SHEET NO. ---- CALCULATEO BY: OF ------------ Valley Center, CA 92082 DATE: _______ _ (760) 7 49-8722 (760) 749-7493 Fax CHECKED BY. DATE _______ _ SCALE: ------------------- STRUCTURAL DESIGN SPECIFICATIONS BUILDING CODE -2019 California Building Code & ASCE 7-16 WOOD FRAMING -Design per 2018 NOS Specification for Wood Construction & Supplement Douglas Fir-Larch graded per WCLIB or WWPA grading rules as follows: Member Type Gracie Fb (pSI) Member Type Grade Joists No 2 900 Studs STUD Beams (2x -4x) No 1 1000 Posts (4x) No 1 Beams(6x or larger B&S No 1 1350 Posts (6x or larger) P&T No 1 STEEL -Design per AISC Specification 360-16 Hot rolled steel complying with ASTM specifications as follows: Section Gracie Fy/Fu /ksi) Section Grade W -Wide Flange A992 50 / 65 Standard Pipe A53 Gr B HSS -Tube A500 Gr C 50 / 62 Plates & Misc A36 WELDING -E70XX Electrodes with Fy = 70ksi unless noted otherwise in calculations CONCRETE -Design per CBC Chapter 19 and ACI 318-14 Specification for reinforced concrete Cof!_crete fc = 25Q_0psi at 28 days unless noted otherwise in calculations. Type II C~ent CONCRETE MASONRY -Design per CBC Chapter 21 and TMS 602-16 Specification for Reinforced Masonry Medium weight solid grouted CMU with fm = 2000psi unless noted otherwise in calculations Mortar -Type M or S Grout fg .: 2000psi STEEL REINFORCING -Bars complying with ASTM A615 (A706 for Welded Bars) as follows: Bar Size Gracie Fy (ks1) Bar Size #3,#4 A615Gr40 40 #5 and larger STRUCTURAL COMPOSITE LUMBER -Manufactured by Trus Joist per ICC-ER ESR-1387. Member Type Parallam (PSL) Microlam (LVL) Gracie OF -2.0E DF -1.9E Fb (psi) 2900 2600 Member Type Timberstrand (LSL) Grade A615Gr60 Grade OF -1.7E GLUE LAMINATED LUMBER -Douglas Fir-Larch Combination 24F-V4 unless noted otherwise in calculations MANUFACTURED WOOD I JOISTS -T JI Pro series by Trus Joist per ICC-ES ESR 1153 RETROFIT EPOXY -Hilti RE-500 V3 designed per ICC ER-381 4 or Simpson SET-XP designed per ICC ESR-2508 Fb (psi) 700 1000 1200 Fy/Fu (ks1) 35160 36158 Fy (ksi) 60 Fb /psi) 2600 WYNN ENGINEERING INC. 27315 Valley Center Road Valley Center, CA 92082 (760) 749-8722 (760) 749-7493 Fax GRAVITY STRUCTURAL LOADS ROOF LOADS Dead Loads Clay Tile Roofing ~ood Decking Framing Insulation Drywall Mechanical Misc. Live Load Total Load WALL LOADS Dead Loads Exterior Walls -Stucco Interior Walls Lateral Live Load -Code Minimum Load (psf) 23.0 10 2.5 4.0 0.5 2.5 1.0 2.5 20.0 43.0 Load (psf) 15.0 10.0 5.0 JOB: SHEET NO .. ---- CALCULATED BY CHECKED BY OF. __________ _ DATE·-------- DATE: ______ _ SCALE: ------------------ FLOOR LOADS Load (psf) Dead Loads 16.0 Finish Flooring 3.0 Plywood Decking 3.5 Framing 4.0 Insulation 0.5 Drywall 2.5 Mechanical 1.0 Misc 1.5 Live Load -General Residential 40.0 Total Load 56.0 WYNN ENGINEERING INC. 27315 Valley Center Road Valley Center, CA 92082 (760) 749-8722 (760) 749-7493 Fax SEISMIC STRUCTURAL LOADS Structure Height h. 23.0ft Risk Category II Soil Profile D Response Modification Factor R 6.5 Importance Factor 1.00 Structure Period Ct 0.020 X 0.75 T, 0.21 Os TL 8.000s 1.S*Ts 0.676s EQUIVALENT LATERAL FORCE PROCEDURE C = p SM ' (R I /) (Eq 12.8-2) = 0.17 C < pSo, s -T(R If) (Eq 12.8-3) = 0.37 Note: Where a soils report is not provided the exceptions given in ASCE 7-10 11.4.8 are used. VERTICAL DISTRIBUTION Heiaht Area Diaph h, a, w, Level n n' psi A Roof 23 2500 23 B Floor 10 2500 16 C Low Roof 10 300 23 0 -E F • These are Ultimate Loads, Multiply by 0.7 for ASD WIND STRUCTURAL LOADS Mean Roof Height h 23.0ft Roof Angle $ 20deg Basic Wind Speed 100 mph JOB· SHEET NO .. ___ _ OF: __________ _ CALCULATED BY CHECKED BY DATE -------- DATE·------- SCALE. ------------------ Mapped 0.2s Acceleration s, 1.07 Mapped 1.0s Acceleration s, 0.39 0.2s Site Coefficient F, 1.20 1.0s Site Coefficient F, 1.50 Design 0.2s Acceleration Sn, 0.86 Design 1.0s Acceleration s,,, 0.39 Redundancy Factor p 1.30 Seismic Design Catego!'.}'. D C~ ~ O.SpS, when S, ~ 0.60 • (Rll) (Eq 12.8-6) = 0.00 Cs= 0.044Susl ~ 0.0 I (Eq 12.8-5) = 0.04 Governing Seismic Response Coefficient Cs = 0.17 Weiaht Moment' FxJ Wall Story w. w~ hr,X Wr, Cs X rw\'.x % psi kip ft-kip % k,o psi 7.5 76.3 1754 67% 18.7 7.5 15 77.5 775 30% 8.2 3.3 7.5 9.2 92 3% 1.0 3.2 162.9 2620 100% 27.9 Importance Factor I 1.00 Exposure Factor -C 1-. 1.21 Topographic Factor K,, 1.00 ZONE Lateral Pressures Vertical Pressures ASCE 7-16 Figure 28.5-1 Design Pressure P,3(1 P, psi psi A 220 26.6 B -5.8 I -7.0 • These are Ultimate Loads, Multiply by 0.6 for ASD C D 14.6 .3 2 17.7 -3.9 E F G H -19.1 -13.3 j -133 I -10 1 -23.1 -16.1 -16.1 -12.2 WYNN ENGINEERING INC. 27315 Valley Center Road Valley Center, CA 92082 (760) 7 49-8722 (760) 749-7493 Fax SOILS PARAMETERS & LOADING JOB SHEET NO .. ___ _ CALCULATED BY CHECKED BY OF.----------- DATE: _______ _ DATE: ______ _ SCALE· _________________ _ Parameters Based on 2019 California Building Code (T1610.1 & T1806.2) General Soils Parameters: Allowable Net Soil Pressure at Minimum Depth ~inimu_i!l Footing Depth Minimum Footing Width Coefficient of Friction Passive Pressure -EFP Retaining Wall Soils Parameters: Allowable Net Soil Pressure at Minimum Depth Minimum Footing Depth Coefficient of Friction Passive Pressure -EFP At Rest Pressure -EFP Active Pressure -Level Slope -EFP Active Pressure -2:1 Slope -EFP 1500 psf 12 in 12in 0.25 100 pcf 1500 psf 12 in 0.25 100 pct 60 pct 45 pct 65 pct WYNN ENGINEERING INC. 27315 Valley Center Road Valley Center, CA 92082 (760) 7 49-8722 (760) 749-7493 Fax Wood Post Capacity Schedule (2)-2x6 (3)-2x6 4x4 4x6 d in 5.5 5.5 ~ 3.5 5.5 -1- b in 3 4.5 3.5 3.5 Fe ps, 850 850 1500 1500 CF 1.15 1.15 1.15 1.1 - Emin mpsi 0.58 0.58 0.62 I 0.62 Height I• -ft 4 13.85 I 22.90 17.34 I 26.37 6 10.18 20.78 11 .78 18.25 -' 8 6.72 17.28 7.48 11.68 --I 10 4.56 13.33 5.00 7.83 12 3.25 10.08 3.55 5.56 --1 14 7.74 2.63 4.13 16 6.07 ,_ -~ --l- 20 t--- 25 -l ~ 30 JOB· ----------------- SHEET NO.: __ _ OF _________ _ CALCULATED BY: ___ _ DATE: ______ _ CHECKED BY DATE:------- SCALE·----------------- Minor Axis is Assumed Unbraced Post Size 4x8 6x6 6x8 6x10 8x8 8x10 7.25 5.5 7.25 9.25 7.25 9.25 I 3.5 5.5 5.5 5.5 7.25 7.25 1500 1000 1000 1000 I 1000 1000 + 1.05 1 1 1 1 1 0.62 0.58 0.58 0.58 0.58 0.58 Post Capacity' Pa -kips 33.56 29.19 38.47 49.09 51.54 65.76 ~ 23.68 27.56 36.34 46.36 50.10 63.92 I 15.29 24.80 32.68 41.70 I 47.77 60.94 t 10.29 20.92 27.57 35.18 44.26 56.47 I 7.31 16.82 22.18 28.29 39.53 50.44 5.44 13.35 17.60 I 22.45 34.09 43.49 10.67 14.07 I 17.95 28.77 36.71 t 7.13 9.40 12.00 20.31 25.91 t- 13.67 17.45 9.72 12.40 2 3 Capacity Per 2015 NOS Section 3.7.1 as Follows: Fe'= C, x Cp x F, x A C0 is calculated as C = I + ( F,,. I F,,.') ,, 2c Where 4 Fe'= C, x F,; c is taken as 0.8 JOB: WYNN ENGINEERING INC. 27315 Valley Center Road SHEET NO.: ___ _ OF:------------- Valley Center, CA 92082 CALCULATED BY: DATE: ________ _ (760) 7 49-8722 (760) 749-7493 Fax CHECKED BY· DATE.--------- SCALE· --------------------- SHEARWALL SCHEDULE MARK3 G H L L2 M -M2 N N2 p P2 WIDTH ALLOW' NAILING SILL CONNECTION2 SEISMIC WIND SIZE/ SPACING 5/8" AB' 16d Nail 260 365 6 / 12 54" 6" 3/8 8d 380 532 4 / 12 42" - 310 435 42" 4" 6 / 12 620 870 24" - 460 645 36" - 4 / 12 920 1290 18" - 15/32 10d 600 840 30" - 3 / 12 1200 1680 15" - 770 1077 20" - 2 / 12 1540 2155 10" - 1 All values assume CDX grade Plywood or OSB panels 2 Values noted are maximum spacings Install a minimum of two (2) fasteners per piece. a) 518" A.B. is 5/8" Diameter A307 J-Bolt with a minimum 7" concrete embedment c) 1/4" SOS is SIMPSON SOS 1/4x4.5 (ICC-ESR 2236) 1/4" sos - 12" - 6" 8" 4" 6" 3" 4" 2" TOP PLATE LTP4 30" 20" 24" 12" 16" 8" 12" 6" 10" 5" 3 Sill and boundary members for walls with a capacity of 350 plf or greater must be 3in nominal lumber mirumum. Naihng edge distance must be 1/2" minim um. 4 Anchor bolts must be installed with minimum 3in x 3in x 0.229in plate washers An anchor must be placed no more than 12" and no less than 7D from each end of the wall WYNN ENGINEERING INC. 27315 Valley Center Road Valley Center, CA 92082 (760) 749-8722 (760) 749-7493 Fax HOLD DOWN HARDWARE SCHEDULE FLOOR MARK TYPE A.B.0 37 MST37 -en 0. <{ 48 MST48 -0:: I-en 60 MST60 - 2 HDU2 5/8" 4 en LU HDU4 5/8" a: 5 LU HDU5 5/8" en :::, 0 8 HDQ8 7/8" I 11 HHDQ11 1" 14 HHDQ14 1" JOB SHEET NO .. ___ _ OF· __________ _ CALCULATED BY· CHECKED BY· _____ DATE· ______ _ DATE.------- SCALE:----------------- CAPACITY NOTES ICC-ER FULL 75% 2465 1849 3695 2771 ER-2105 4665 I 3499 3075 2306 4565 3424 ER-2330 5645 4234 r 7630 5723 11810 I 8858 ER-2330 13015 9761 I WYNN ENGINEERING INC. 27315 Valley Center Road Valley Center, CA 92082 Valley Center (760) 749-8722 Los Angeles (310) 306-9728 www.wynnenglneering.com J I /, I, I I!, 1 V:.-1?/3!'A / 17 ;== /CJt? I 1/J-' VJE ft()v?-~ JOB ____________________ _ SHEET NO. _________ _ OF _______ _ CALCULATED BY ________ _ DATE ______ _ CHECKED BY ________ _ DATE ______ _ SCALE ___________________ _ .. 0 . .. . 0 D PRODUCT 207 I : Multiple Simple Beam Software copyright ENERCALC, INC 1983-2020, Build:12.20.8.24 I ,I Description : Wood Beam Design : Header A Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size : 6x10, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir • Larch Wood Grade : No. 1 Wood Species : Fb -Tension Fb -Compr 1,350.0 psi Fe -Prll 925.0 psi Fv 170.0 psi Ebend-xx 1,350.0 psi Fe -Perp 625.0 psi Ft 675.0 psi Eminbend -xx Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.0150, L = 0.040 k/ft, Trib= 2.750 ft Unif Load: D = 0.0230, Lr= 0.020 k/ft, 0.0 to 2.50 ft, Trib= 14.50 ft Unif Load: D = 0.0230, Lr = 0.020 k/ft, 3.750 to 6.250 ft, Trib= 6.0 ft Point: D = 1.670, Lr= 1.450 k @ 2.50 ft Point: D = 0.5870, Lr= 0.510 k@ 3.750 ft ·:.. 1,600.0 ksi 580.0 ksi Density 31.210 pcf Design Summary Max fb/Fb Ratio fb: Actual : 0.650 · 1 1,090.06 psf at 1,676.71 psi +D+Lr+H 2.500 ft in Span# 1 -----------------Fb : Allowable : Load Comb: .... Max fv/FvRatio = fv : Actual : 0.448: 1 95.19 psi at 212.50 psi +D+Lr+H 0.000 ft in Span# 1 6.250 ft Fv : Allowable : Load Comb: Max Reactions Left Support Right Support (k) Q L 2.14 0.34 1.63 0.34 L!: 1.71 1.27 Wood Beam Design: Header B .E 1:1 Ratio Transient Upward Ratio 0.034 in 2221 LC: Lr Only 0.000 in 9999 LC: Total Downward Ratio 0.076 in 993 LC: +D+Lr+H 0.000 in 9999 LC: Total Upward Ratio Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: Wood Species : Fb • Tension Fb -Compr Applied Loads 4x10, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir -Larch Wood Grade : No.1 1,000.0 psi Fe -Prll 1,500.0 psi Fv 180.0 psi Ebend-xx 1,000.0 psi Fe -Perp 625.0 psi Ft 675.0 psi Eminbend -xx Beam self weight calculated and added to loads Unit Load: D = 0.0150, L = 0.040 k/ft, Trib= 10.0 ft Design Summary Max fb/Fb Ratio fb : Actual : Fb : Allowable : Load Comb : 0.551 · 1 653.91 psi at 1,186.91 psi +D+L+H 3.125 ft in Span # 1 1,700.0ksi 620.0 ksi Density 31210pcf Max fv/FvRatio = fv : Actual : 0.341 : 1 61.29 psi at 180.00 psi +D+L+H 5. 500 ft in Span # 1 6.250 ft 1 Fv : Allowable : Load Comb : Max Reactions Left Support Right Support (k) D. L Lr Yi. 0.49 1.25 0.49 1.25 ax e ect1ons .E l:! Transient Downward Ratio LC: Transient Upward Ratio 0.035 in Total Downward 0.049 in 2131 Ratio 1530 LOnly LC: +D+L+H 0.000 in Total Upward 0.000 in 9999 Ratio 9999 LC: LC: I ; Multiple Simple Beam Software l'.Xlpyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 ... Wood Beam Design : Header C Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: Wood Species : Fb -Tension Fb -Compr Applied Loads 4x8, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir -Larch Wood Grade : No. 1 1,000.0 psi Fe -Prll 1,500.0 psi Fv 180.0 psi Ebend-xx 1,000.0 psi Fe -Perp 625.0 psi Ft 675.0 psi Eminbend -xx Beam self weight calculated and added to loads Unif Load: D = 0.0150, L = 0.040 k/ft, Trib= 10.0 ft Design Summary Max fb/Fb Ratio = fb : Actual: Fb : Allowable : Load Comb : 0.824; 1 1,061.55 ps, at 1,288.84 psi +D+L+H 3. 125 ft in Span # 1 1,700.0ksi 620.0 ksi Density 31 .210 pct Max fv/FvRatio = fv : Actual: 0.464 : 1 83.46 psi at 180.00 psi +D+L+H 5.667 ft in Span# 1 6.250ft Fv : Allowable : Load Comb : Max Reactions Left Support Right Support (k) Q L 0.49 1.25 049 1.25 Lr .s. 'fl. !::! Max De ections Transient Downward 0.073 in 1026 Ratio Transient Upward Ratio LC: L Only 0.000 in 9999 LC Total Downward 0.101 in 739 LC: +D+L+H 0.000 in 9999 Ratio Total Upward Ratio LC: WYNN ENGINEERING INC. 27315 Valley Center Road Valley Center, CA 92082 (760) 7 49-8722 (760) 749-7493 Fax Square Pad Footing Schedule Foundation Parameters Allowable Soil Pressure pa 1500 psf Concrete Strength fc 2500 psi Reinforcing Strength fy 40000 psi Concrete Shear Capactty VC 100 psi Minimum Column Diameter De 3.5 in Mark Length Depth 2 Reinforcing L D d Count Size As Rho> ~ ,n ,n in n # sqm % A 1 12 12 8 2 4 0.39 0.41% -- B 1.5 18 12 8 2 4 0.39 0.27% C 2 24 12 8 3 4 0.59 0.31% D 2.5 30 12 8 3 4 0.59 0.25% E 3 36 12 8 4 4 0.79 0.27% F 3.5 42 12 8 4 4 0.79 0.23% G 4 48 18 14 6 4 1.18 0.18% H 5 60 18 14 6 4 1.18 0.14% J 6 72 18 14 8 4 1.57 0.16% (1) Concrete Shear Capacity. 1 00ps, V c = 2.JJ: (2) Depth to Steel Assume 41n from (3) Minimum Steel Pm., = 0.0014 (4) Soil Bearing P,, = p,,L2 JOB· SHEET NO: ---- CALCULATED BY CHECKED BY. OF· ------------ DATE·-------- DATE: _______ _ SCALE· ------------------- Capacity Rho One Two (min) 3 Pu Bearing 4 Way5 Way6 Bending 7 % kip lb lb lb lb 0.14% 1.5 1500 9600 18400 42644 0.14% 3.4 3375 14400 18400 28809 0.14% 6.0 6000 19200 18400 32303 0.14% 9.4 9375 24000 18400 25996 0.14% 13.5 13500 28800 18400 28809 0.14% 18.4 18375 33600 18400 24786 0.14% 24.0 24000 67200 49000 57251 0.1 4% 37.5 37500 84000 49000 45955 0.14% 49.0 54000 100800 49000 50985 I (5) One Way Shear Capacity P,, = I:?¢. Ve x 2dl I (6) Two Way Shear Capacny /> = -,1, v x 4( D + d)d II 1.7 if/-.,, C C I 2 ( I Ply) (7)Bend1n9Capacny P,, = -¢0 8pd I,-1----1.7 t.7 I, civil engineering s tructural des ig n land surveying STRUCTURAL CALCULATIONS REMODEL CASSINS 13 7 6 Cassins St. Carlsbad, CA 92011 Job No: 2 1-637 October 4, 2021 27315 Valley Center Road-Valley Center, CA 92082 -(760) 749-8722-Fax (760) 749-9412 Email: wynneng@wynnengineering.com -Los Angeles (3 10) 306-9728 -Fax (31 0) 306-2129 JOB: WYNN ENGINEERING INC. 27315 Valley Center Road SHEET NO.: ___ _ OF: ___________ _ Valley Center, CA 92082 CALCULATED BY: DATE; _______ _ (760) 749-8722 (760) 749-7493 Fax CHECKED BY: DATE:-------- SCALE: ------------------- STRUCTURAL DESIGN SPECIFICATIONS BUILDING CODE-2019 California Building Code & ASCE 7-16 WOOD FRAMING -Design per 2018 NOS Specification for Wood Construction & Supplement Douglas Fir-Larch graded per WCLIB or WWPA grading rules as follows: Member Type Grade Fb (psi) Member Type Grade Joists No2 900 Studs STUD Beams (2x -4x) No 1 1000 Posts (4x) No 1 Beams(6x or larger B&S No 1 1350 Posts (6x or larger) P&T No 1 STEEL -Design per AISC Specification 360-16 Hot rolled steel complying with ASTM specifications as follows: Section Grade Fy/Fu (ks,2 Secfjon Grade W -Wide Flanl,!e A992 50/65 Standard Pipe A53 Gr B HSS-Tube A500 Gr C 50 /62 Plates & Misc A36 WELDING -E70XX Electrodes with Fy = 70ksi unless noted otherwise in calculations CONCRETE-Design per CBC Chapter 19 and ACI 318-14 Specification for reinforced concrete Concrete fc = 2500psi at 28 days unless noted otherwise in calculations. Type II Cement CONCRETE MASONRY -Design per CBC Chapter 21 and TMS 602-16 Specification for Reinforced Masonry Medium weight solid grouted CMU with fm = 2000psi unless noted otherwise in calculations Mortar -Type M or S Grout fg ;,: 2000psi STEEL REINFORCING -Bars complying with ASTM A615 (A706 for Welded Bars) as follows: Bar Size Grade Fy (ks,) Bar Size #3,#4 A615 Gr 40 40 #5 and larger STRUCTURAL COMPOSITE LUMBER-Manufactured by Trus Joist per ICC-ER ESR-1387. Member Type Grade Fb (PSI) Member Type Parallam (PSL) DF-2.0E 2900 Timberstrand (LSL) Microlam (L VL) OF -1.9E 2600 Grade A615 Gr 60 Grade OF -1.7E GLUE LAMINATED LUMBER -Douglas Fir-Larch Combination 24F-V4 unless noted otherwise in calculations MANUFACTURED WOOD I JOISTS -T JI Pro series by Trus Joist per ICC-ES ESR 1153 RETROFIT EPOXY -Hilti RE-500 V3 designed per ICC ER-3814 or Simpson SET-XP designed per ICC ESR-2508 Fb (ps,) 700 1000 1200 Fy/Fu (ksi) 35/60 36 / 58 Fy (ks1J 60 Fb (psi) 2600 I • 1· " \ • j 1J i' WYNN ENGINEERING INC. 27315 Valley Center Road Valley Center, CA 92082 (760) 749-8722 (760) 749-7493 Fax GRAVITY STRUCTURAL LOADS ROOF LOADS Load (psi) Dead Loads 23.0 Cla~ Tile Roofin9 10 Plywood Deckin9 2.5 Framing 4.0 Insulation 0.5 Drywall 2.5 Mechanical 1.0 Misc. 2.5 Live Load 20.0 Total Load 43.0 WALL LOADS Load (psi) Dead Loads Exterior Walls -Stucco 15.0 Interior Walls 10.0 Lateral Live Load -Code Minimum 5.0 JOB: SHEET NO.: ---- CALCULATED BY: CHECKED BY: OF:----------- DATE; _______ _ DATE:-------- SCALE:------------------ FLOOR LOADS Load (psi) Dead Loads 16.0 Finish Floorin9 3.0 Plywood Deckin9 3.5 Framin9 4.0 Insulation 0.5 Drywall 2.5 Mechanical 1.0 Misc 1.5 Live Load -General Residential 40.0 Total Load 56.0 WYNN ENGINEERING INC. 27315 Valley Center Road Valley Center, CA 92082 (760) 749-8722 (760) 749-7493 Fax SEISMIC STRUCTURAL LOADS Structure Height 23.0ft Risk Category II Soil Profile D Response Modification Factor R 6.5 Importance Factor 1.00 Structure Period Ct 0.020 X 0.75 T, 0.210s TL 8.000s l.5*Ts 0.676s EQUIVALENT LATERAL FORCE PROCEDURE C = pSos ' (Rll) (Eq 12.8-2) = 0.17 C < pSDI s -T(RI I) (Eq 12.8-3) = 0.37 Note: Where a soils report is not provided the exceptions given in ASCE 7-10 11.4.8 are used. VERTICAL DISTRIBUTION Heiaht Area h, ... Level It tt' A Roof 23 2500 B Floor 10 2500 C Low Roof 10 300 D E F Diaph w, psf 23 16 23 • These are Ultimate Loads, Multiply by 0.7 for ASD WIND STRUCTURAL LOADS Mean Roof Height h 23.0ft Roof Angle t 20deg Basic Wind Speed 100 mph JOB: ------------------- SHEET NO.: ---- CALCULATED BY: OF:------------ DATE: _______ _ CHECKED BY: DATE: _______ _ SCALE: ------------------- Mapped 0.2s Acceleration Ss 1.07 Mapped 1.0s Acceleration S1 0.39 0.2s Site Coefficient F, 1.20 1.0s Site Coefficient F,. 1.50 Design 0.2s Acceleration Sos 0.86 Design 1.0s Acceleration Soi 0.39 Redundancy Factor p 1.30 Seismic Design Category D C 0.5pSI O 60 s 2'. (RI I) when S1 2'. • (Eq 12.8-6) = 0.00 Cs= 0.044Sosl 2'. 0.01 (Eq 12.8-5) = 0.04 Governing Seismic Response Coefficient Cs = 0.17 Weiahe Momenf Fx" Wall Story w., w, bxx Wx CsxI:wxx ¾ psf kip It-kip % kip psf 7.5 76.3 1754 67% 18.7 7.5 15 77.5 775 30% 8.2 3.3 7.5 9.2 92 3% 1.0 3.2 162.9 2620 100% 27.9 Importance Factor 1.00 Exposure Factor -C A. 1.21 Topographic Factor Kzt 1.00 ZONE Lateral Pressures Vertical Pressures A B C D E F G H ASCE 7-16 Figure 28.5-1 P,30 psf 22.0 -5.8 14.6 -3.2 -19.1 -13.3 -13.3 -1 0.1 Design Pressure P, psf 26.6 -7.0 17.7 -3.9 -23.1 -16.1 -16.1 -12.2 • These are Ultimate Loads, Multiply by 0.6 for ASD I j I 1:! l1 • I WYNN ENGINEERING INC. 27315 Valley Center Road Valley Center, CA 92082 (760) 749-8722 (760) 749-7493 Fax SOILS PARAMETERS & LOADING JOB: ------------------- SHEET NO.: ___ _ OF:------------ CALCULATED BY: DATE: _______ _ CHECKED BY: DATE: _______ _ SCALE: ------------------- Parameters Based on 2019 California Building Code (T1610.1 & T1806.2) General Soils Parameters: Allowable Net Soil Pressure at Minimum Depth 1500 psf Minimum Footing Depth 12in Minimum Footing Width 12 in Coefficient of Friction 0.25 Passive Pressure -EFP 100 pcf Retaining Wall Soils Parameters: Allowable Net Soil Pressure at Minimum Depth 1500 psf Minimum Footing Depth 12 in Coefficient of Friction 0.25 Passive Pressure -EFP 100 pcf At Rest Pressure -EFP 60 pcf Active Pressure -Level Slope -EFP 45 pcf Active Pressure -2:1 Slope -EFP 65 pcf ' ,. 11 JOB: I WYNN ENGINEERING INC. 27315 Valley Center Road SHEET NO.: OF: Valley Center, CA 92082 CALCULATED BY: DATE: (760) 749-8722 (760) 749-7493 Fax CHECKED BY: DATE: SCALE: ' Wood Post Capacity Schedule Minor Axis is Assumed Unbraced Post Size (2)-2x6 (3)-2x6 4x4 4x6 4x8 6x6 6x8 6x10 8x8 8x10 d in 5.5 5.5 3.5 5.5 7.25 5.5 7.25 9.25 7.25 9.25 ' b in 3 4.5 3.5 3.5 3.5 5.5 5.5 5.5 7.25 7.25 ,;r: Fe psi 850 850 1500 1500 1500 1000 1000 1000 1000 1000 . CF 1.15 1.15 1.15 1.1 1.05 1 1 1 1 1 Emin mpsi 0.58 0.58 0.62 0.62 0.62 0.58 0.58 0.58 0.58 0.58 Height Post Capacity1 I e -ft P a -kips 4 13.85 22.90 17.34 26.37 33.56 29.19 38.47 49.09 51.54 65.76 11l r •I I ~ 6 10.18 20.78 11.78 18.25 23.68 27.56 36.34 46.36 50.1 0 63.92 8 6.72 17.28 7.48 11.68 15.29 24.80 32.68 41.70 47.77 60.94 10 4.56 13.33 5.00 7.83 10.29 20.92 27.57 35.18 44.26 56.47 ~: ► I 12 3.25 10.08 3.55 5.56 7.31 16.82 22.18 28.29 39.53 50.44 14 7.74 2.63 4.13 5.44 13.35 17.60 22.45 34.09 43.49 16 6.07 10.67 14.07 17.95 28.77 36.71 i 20 7.13 9.40 12.00 20.31 25.91 .. 25 13.67 17.45 30 9.72 12.40 2 Capacity Per 2015 NOS Section 3. 7 .1 as Follows: F .• = CF x c. x F c x A. ' ! 3 CP is calculated as (1 +(1:/ F,.) J-(F,E IF,•) C =1+(F,E IF,.)_ Where F = 0.822E P 2c C cE (/, / d}2 4 F; = CF x F.; c is taken as 0.8 JOB: WYNN ENGINEERING INC. 27315 Valley Center Road SHEET NO.: ---- CALCULATED BY: OF: ____________ _ Valley Center, CA 92082 DATE: ________ _ (760) 7 49-8722 (760) 749-7493 Fax CHECKED BY: DATE: ________ _ SCALE: --------------------- SHEARWALLSCHEDULE MARK3 WIDTH ALLOW1 NAILING SILL CONNECTION2 TOP PLATE G H L L2 M M2 N N2 p P2 SEISMIC WIND SIZE I SPACING 5/8" A.B' 16d Nail 260 365 6 / 12 54" 6" 3/8 8d 380 532 4 / 12 42" - 310 435 42" 4" 6 / 12 620 870 24" - 460 645 36" - 4 / 12 920 1290 18" - 15/32 10d 600 840 30" - 3 / 12 1200 1680 15" - 770 1077 20" - 2 / 12 1540 2155 10" - 1 Al values assume COX grade Plywood or OSB panels 2 Values noted are maximum spacings. Install a minimum of two (2) fasteners per piece. a) 5/8" A.B. is 5/8" Diameter A307 J-Bolt with a minimum 7" concrete embedment. c) 1/4" SOS is SIMPSON SOS 1/4x4.5 (ICC-ESR 2236) 1/4" sos LTP4 -30" 12" 20" -24" 6" 12" 8" 16" 4" 8" 6" 12" 3" 6" 4" 10" 2" 5" 3 Sill and boundary members for walls with a capacity of 350 p~ or greater must be 3in nominal lumber minimum. Nailing edge distance must be 1/2" minimum. 4 Anchor bolts must be installed with minimum 3in x 3in x 0.229in plate washers. An anchor must be placed no more than 12" and no less than 70 from each end of the wall. WYNN ENGINEERING INC. 27315 Valley Center Road Valley Center, CA 92082 (760) 7 49-8722 (760) 749-7493 Fax HOLD DOWN HARDWARE SCHEDULE FLOOR MARK TYPE A.B.0 en 37 MST37 - a.. <( 0::: 48 MST48 -I-en 60 MST60 - 2 HDU2 5/8" 4 HDU4 5/8" en w ii: 5 HDU5 5/8" w en ::> 8 HDQ8 7/8" 0 I 11 HHD011 1" 14 HHDQ14 1" JOB: SHEET NO.: ---- CALCULATED BY: CHECKED BY: OF:----------- DATE: ______ _ DATE: ______ _ SCALE:----------------- CAPACITY NOTES ICC-ER FULL 75% 2465 1849 3695 2771 ER-2105 4665 3499 3075 2306 4565 3424 ER-2330 5645 4234 7630 5723 11810 8858 ER-2330 13015 9761 Multiple Simple Beam Software copyright ENERCALC, ING. 198 ,., Description: Wood Beam Design : Header A Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-1~ 6x10, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Wood Species : Douglas Fir -Larch Wood Grade : No.1 BEAM Size: Fb -Tension 1,350.0 psi Fe -Prll 925.0 psi Fv 170.0 psi Ebend-xx Fb -Compr 1,350.0 psi Fe -Perp 625.0 psi Ft 675.0 psi Eminbend -xx 1,600.0 ksi 580.0 ksi Density 31.210 pcf Applied Loads Beam self weight calculated and added to loads Unit Load: D = 0.0150, L = 0.040 k/ft, Trib= 2.750 ft Unit Load: D = 0.0230, Lr= 0.020 k/ft, 0.0 to 2.50 ft, Trib= 14.50 ft Unit Load: D = 0.0230, Lr= 0.020 k/ft, 3.750 to 6.250 fl, Trib= 6.0 ft Point: D = 1.670, Lr= 1.450 k @ 2.50 ft Point: D = 0.5870, Lr= 0.510 k@3.750 ft Design Summary Max fb/Fb Ratio = fb: Actual: Fb : Allowable : Load Comb : Max fv/FvRatio = fv: Actual : Fv : Allowable : Load Comb : 0.650 • 1 1,090.06 psf at 1,676.71 psi +D+Lr+H 0.448: 1 95.19 psi at 212.50 psi +D+Lr+H Q .L. I.! Max Reactions (k) Left Support 2.14 0.34 1.71 Right Support 1.63 0.34 1.27 2.500 ft in Span # 1 0.000 ft in Span # 1 Yi. f. Wood Beam Design : Header B .ti Max Deflections Transient Downward Ratio 0.034in 2221 LC: Lr Only Transient Upward 0.000 in Ratio 9999 LC: Total Downward Ratio 0.076 in 993 Total Upward Ratio LC: +D+Lr+H 0.000 in 9999 LC: Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 4x10, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Wood Species : Fb -Tension Fb -Compr Douglas Fir -Larch Wood Grade : No.1 1,000.0 psi Fe -Prll 1,500.0 psi Fv 180.0 psi Ebend-xx 1,700.0 ksi 620.0 ksi Density 31.210pcf ~ 1,000.0 psi Fe -Perp 625.0 psi Ft 675.0 psi Eminbend -xx Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.0150, L = 0.040 k/ft, Trib= 10.0 ft Design Summary Max fb/Fb Ratio = fb : Actual : Fb : Allowable : Load Comb: Max fv/FvRatio = fv : Actual : Fv : Allowable : Load Comb: 0.551 ; 1 653.91 psi at 1,186.91 psi +D+L+H 0.341 : 1 61.29 psi at 180.00 psi +D+L+H Q I. .L.r Max Reactions (k) Left Support 0.49 1.25 Right Support 0.49 1.25 3.125 ft in Span# 1 5.500 ft in Span # 1 f .ti ------------. --- 6.250 ft Max e ections Transient Downward 0.035 in 2131 LC: L Only Ratio Transient Upward 0.000 in Ratio 9999 LC: Total Downward Ratio 0.049 in 1530 Total Upward Ratio LC:+D+L+H 0.000 in 9999 LC: , I !.; WYNN ENGINEERING INC. 27315 Valley Center Road JOB _________________________ _ Valley Center, CA 92082 Valley Center (760) 749-8722 Los Angeles (310) 306-9728 www.wynnengineering.com SHEET NO. ____________ _ OF __________ _ CALCULATED BY ___________ _ DATE ________ _ CHECKED av ____________ _ DATE _________ _ SCALE __________________________ _ ' 7 7 a 1 'J. l .; $ ti 7 e I I , .\ S i, I 11 I :t ,I ' . " ..... I : . ~:··:'r::i::.::::::: • .. L .... :: .. j~::>:'..~ .. ),A:,;:L::( ... :.;1:~, A? ;.:: k1 s. : . ~ ., ..... • ./2): r1c;,.. /¥.: . ' ,;., .. , ..... ~ ., i .,1 .. ' ~ ........ : ..... :·" ··=· i .. ; , ·.i}:.;4 ·.~.:!.{,/Q.(~"-:;c.5~:o : ..... + .. ·if;'.J.'J:.1J..tp .. 1cir.:t:✓-&'t'J. ... j_· '::·(: ;;,;::--;: '.Zl '(f:f/.<J/j z.· Vb C f • ' • • • · ... c. ,. fr..,P I/)!.. f . : . . c:i.=: -----:--:· .• ... n } •lf 1?::1,:_JEL_:;~L~,(:cc-· "b .• zr ;)t E !)i 1'-'.··· + 2il<i.tL2.r:9lCZ ~D-).· ................................... , ............. . ~ .... ,. l/':--"==--:A-r ! 9 q 1%1%J . . j I .;:;: W .:.; •••• , ... . . :uie .. ~f ro:i--·J 7 .. ".; .... ' .. .:~:. : . ~.; :,, ,.,, ...... ; .... ' ......... _ ...... . I ! " ••• t' .... "':''·:··; : . ~ .. ~ . ! ........... ; • ......... i .... : .. . .,, . : .. ~ .. ..,.. -:-.. +· ..... ?..f~2e~ ... : .. i,~.::+ :.: .. ; .... : :.· ;.: c:; ... :.):~+-:-.;--:r.-1;J,cj.5k.) .. ~Jc: 5: .. :,J: .. -.. L~/lj..A:: ;.r c .. 2:1= .. lf-ftc.14?1) : ... i·· . . • . ; . ; •• .J :ti .. :-:z· t?-~ 1 :r ·.: /rt . ....... :, ... :. ,ri .. ,, ........ H.•••••••"•••'"• .................................. . .. ) ... .. ·• t .......... 7 -:-• . :~,7~& 0 r·· :,:: -ft--J'.tt( F~~-~.1> +fl~ ~7 ilf ~g -Cfi?7f4,zz/. .. -r• • , ... ,........... . . ·.::; .... , .... t ~: . 2 .. 7 I :.f:.~ ... 17 : ~.f· !:?•?·O·: ·t\tf · ·2 .....• ?;-fc(( 1 f) • i . /, i'lJ-/d{ ; h :~ q_·.'2 ... ! . • ' D PROOUCT207 . . 1e: .e Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 Wood Beam Design : Header C Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 4x8, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending , Wood Species : Douglas Fir -Larch Wood Grade : No.1 Fb -Tension Fb-Compr 1,000.0 psi Fe -Prll 1,500.0 psi Fv 180.0 psi Ebend-xx 1,700.0 ksi 620.0ksi Density 31.210 pcf 1,000.0 psi Fe -Perp 625.0 psi Ft 675.0 psi Eminbend -xx Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.0150, L = 0.040 k/ft, Trib= 10.0 ft Design Summary Max fb/Fb Ratio = fb: Actual : Fb : Allowable : Load Comb: .. !Max fv/FvRatio = l ' fv : Actual : Fv : Allowable : L!oad Comb : 0.824; 1 1,061.55 psi at 1,288.84 psi +D+L+H 0.464: 1 83.46 psi at 180.00 psi +D+L+H 0. L Lr Max. Reactions {k) Left Support 0.49 1.25 Right Support 0.49 1.25 3.125ft inSpan#1 5.667 ft in Span # 1 '.ff.. f ------------------.-----_;--__ _ __ -__ ---· _.:._ ____ -_;_ - J:j Max e ect,ons Transient Downward Ratio 4x8 s.2so n 0.073 in 1026 LC: L Only Transient Upward 0.000 in Ratio 9999 LC: Total Downward Ratio 0.101 in 739 Total Upward Ratio LC:+D+L+H 0.000 in 9999 LC: WYNN ENGINEERING INC. 27315 Valley Center Road Valley Center, CA 92082 (760) 749-8722 (760) 749-7493 Fax Square Pad Footing Schedule Foundation Parameters Allowable Soil Pressure pa 1500 psf Concrete Strength fc 2500 csi Reinforcing Strength f}'. 40000 psi Concrete Shear Capacity VC 100 psi Minimum Column Diameter De 3.5 in Mark Length Depth 2 Reinforcing L D d Count Size As Rho > ft in in in n # sqin % A 1 12 12 8 2 4 0.39 0.41 % B 1.5 18 12 8 2 4 0.39 0.27% C 2 24 12 8 3 4 0.59 0.31% D 2.5 30 12 8 3 4 0.59 0.25% E 3 36 12 8 4 4 0.79 0.27% F 3.5 42 12 8 4 4 0.79 0.23% G 4 48 18 14 6 4 1.18 0.18% H 5 60 18 14 6 4 1.18 0.14% J 6 72 18 14 8 4 1.57 0.16% (1) Concrete Shear Capacity. 100psiV< = 2.JJ: (2) Depth to Steel. Assume 4in from (3) Minimum Steel p..,, = 0.0014 (4) Soil Bearing P,, = PaLZ JOB: SHEET NO.: ___ _ OF:------------ CALCULATED BY: ____ _ DATE: _______ _ CHECKED BY: ------DATE: _______ _ SCALE: ------------------- ! ;: t ' I Capacity I~: Rho One Two • ·1 (min) 3 Pu Bearing• Way5 Way• Bending 7 • t % kip lb lb lb lb 0.14% 1.5 1500 9600 18400 42644 0.14% 3.4 3375 14400 18400 28809 0.14% 6,0 6000 19200 18400 32303 ' J ~ } Ii 0.14% 9.4 9375 24000 18400 25996 0.14% 13.5 13500 28800 18400 28809 0.14% 18.4 18375 33600 18400 24786 ., 1 1; 0.14% 24.0 24000 67200 49000 57251 0.14% 37.5 37500 84000 49000 45955 0.14% 49.0 54000 100800 49000 50985 . 1 l I (5) One Way Shear Capacity P = -¢ v X 2dL II 1.7 \I C I . l (6) Two Way Shear Capacity P = -¢ v x 4(D + d)d II 1.7 \' C C l , ( l r:fy) (7) Bending Capacity P. = -tpb 8 {Xi -J y l ----l.7 1.7 f c ''.) ~ : C cicyof Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Servic,es Building Div~ l 1635 Faraday Avenue {760} 602-2719 www .carlsbadca.gov This checklist is intended to help building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their project. This completed checklist (B-50) must be included with the building permit application. The Carlsbad Municipal Code (CMC) can be referenced during completion of this document by clicking on the provided links to each municipal code section. NOTE: The following type of permits are not required to fill out this form ❖ Patio ❖ Decks ❖ PME (w/o panel upgrade) ❖ Pool Consultation with a certified Energy Consultant is encouraged to assist in filling out this document. Appropriate certification includes, but is not limited to: Licensed, practicing Architect, Engineer, or Contractor familiar with Energy compliance, IECC/HERS Compliance Specialist, ICC G8 Energy Code Specialist, RESNET HERS rater certified, certified ICC Residential Energy Inspector/Plans Examiner, ICC Commercial Energy Inspector and/or Plans Examiner, ICC CALgreen Inspector/Plans Examiner, or Green Building Residential Plan Examiner. If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, check N/A and provide an explanation or code section describing the exception. Details on CAP ordinance requirements are available at each section by clicking on the municipal code link provided. The project plans must show all details as stated in the applicable Carlsbad Municipal Code (CMC) and/or Energy Code and Green Code sections. Project Name/Building Permit No.: Property Address/APN: Applicant Name/Co.: Applicant Address: Contact Phone: ~J~¼¾! t !~ . . . > d BP No.: C1 Contact information of person completing this checklist (if different than above): Name: Company name/address: Contact Phone: Contact Email: Applicant Signature: ~'V 9: =-J.~----Date: II -C> 'b -2.. 0 "2 \ B-50 Page 1 of 7 Revised 04/21 q '2-o l I Use the table below to determine which sections of the Ordinance checklist are applicable to your project. For alterations and additions to existing buildings, attach a Permit Valuation breakdown on a separate sheet. Building Permit Valuation (BPV) $ breakdown fl;:);l, 37 / -3 / D New construction D Addlona llld ateratlona: D BPV < $60,000 D BPV c::: $60,000 D Electrical service panel upgrade only D BPV c::: $200,000 New construction D BPV c::: $200,000 or additions c::: 1,000 square feet D BPV.::: $1,000,000 ' D ~ 2,000 sq. ft. new roof addition A high-rise residential building is 4 or more stories, including a Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use 2A*, 3A*, 4A*, N/A 1A, 4A 1A, 4A* 1B, 2B, 3B,4A N/A 4A 1B, 4A* 1 B, 2B, 3B, 4B and 5 1B, 5 18,28,5 2B,5 *Includes detached, newly constructed ADU All residential additions and alterations 1-2 family dwellings and townhouses with attached garages only. *Multi-family dwellings only where interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed Building alterations of~ 75% existing gross floor area 1B also applies if BPV ~ $200,000 ~ Please refer to Carlsbad Municipal Code (CMC) 18.21.155 and 18.30.190,and the California Green Building Standards Code (CALGreen) for more infoonation. Appropriate details and notes must be placed on the plans according to selections chosen in the design. A. D Residential addition oralteration~$60,000building pennitvaluation. □ NIA _________ _ Details of selection chosen below must be placed on the plans referencing CMC □ Exception: Home energy score ~ 7 18.30.190. (attach certification) ·I Y,ear Built Single-family Requirements Multi-family Requirements □ Before 1978 Select one option: □ Ductsealing □ Attic insulation □Cool roof □ Attic insulation □ 1978 andlater Select one option: □ Lighting package □ Water heating Package □ Between1978and1991 Select one option: □ Ductsealing □ Attic insulation □Cool roof □ 1992 and later Select one option: □ Lighting package □ Water heating package Updated 4/1 6/202 I 3 B. D Nonresidential* new construction or alterations 2: $200,000 building pennit valuation, or additions 2: 1,000square feet See CMC 18.21.155and CALGreen Appendix AS □ N/A AS.203.1.1 Choose one:□ .1 Outdoor lighting D .2 Restaurant service water heating (CEC 140.5) □ .3 Warehouse dock seal doors. □ .4 Daylight design PAFs □ .5 Exhaust air heat recovery □ N/A AS.203.1.2.1 Choose one: D .95 Energy budget (Projects with indoor lighting OR mechanical) D .90 Energy budget (Projects with indoorlightingANDmechanical) □ N/A AS.211.1 ** D On-site renewable energy: □ N/A AS.211.3... □ Green power: (If offered by local utility provider, 50% minimum renewable sources) D N/A AS.212.1 □ Elevators and escalators: (Project with more than one elevatorortwo escalators) D N/A D N/A 'i 1i -------------------------------==--....:...:.:.:....::::=:===============::..c!..· AS.213.1 □ Steel framing: (Provide details on plans for options 1-4 chosen) * Includes hotels/motels and high-rise residential buildings ** For alterations~ $1,000,000 BPVand affecting> 75% existing grossfloorarea, OR alterations that add 2,000square feet of newroofadd~ion: comply with CMC 18.30.130 (section 28 below) instead. 2. Photovoltaic Systems A. D Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. If project includes installation of an electric heat pump water heater pursuant to CAP section 38 below(low-rise residential Water Heating), increase system size by .3kWdc if PVoffsetoption is selected. Floor Plan ID (use additional CFA #d.u. Calculated kWdc* sheets if necessary) Total System Size: kWdc = (CFAx.572) / 1,000 + (1 .15 x #d.u.) *Formula calculation where CFA = conditional floor area, #du= number of dwellings per plan type If proposed system size is less than calculated size, please explain. kWdc Exception □ □ ,, □ □ B. D Nonresidential new construction or alterations 2:$1,000,000 BPV AND affecting 2:75% existing floor area, OR addition that increases roof area by 2:2,000 square feet Please refer to CMC 18.30.130 when completing this section. *Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: □ Gross Floor Area (GFA)Method GFA: □ If< 10,000s.f. Enter: 5 kWdc Min. System Size: □ If~ 10,000s.f. calculate: 15 kWdcx (GFN10,000) ** kWdc **Round building size factor to nearest tenth, and round system size to nearest whole number. Updated 4/16/2021 ··• ' ,. I - 4 □ Time-Dependent Valuation Method AnnualTDV Energy use:•-______ x .80= Min. system size: ______ kWdc .... Attach calculation documentation using modeling software approved by the California Energy Commission. HNtlng A. D Residential and hotel/motel new construction. Refer to CM~ 18.30.170 when completing this section. Provide complete details on the plans. D For systems serving individual dwelling units choose one system: D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) D Heat pump water heater AND PV system .3 kWdc larger than required in CMC 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1 ( c) 14 (low-rise residential) D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors D Exception: D For systems serving multiple dwelling units, install a central water-heating system with ALL of the following: D Gas or propane water heating system D Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18. 30.170(8) (low- rise residential) D Solar water heating system that is either: D .20 solar savings fraction D .15 solar savings fraction, plus drain water heat recovery D Exception: • '8. D Nonresidential new construction. Refer to CMC 18.30.150 when completing this section. Provide complete details on the plans. D Water heating system derives at least 40% of its energy from one of the following (attach documentation): D Solar-thermal D Photovoltaics D Recovered energy D Water heating system is (choose one): D Heat pump water heater D Electric resistance water heater(s) □Solar water heating system with .40 solar savings fraction D Exception: It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a P,erformance approach to comply with energy-related measures will need to attach to this checklist separate calculations an,d aocumentation as specified by the ordinances . • I • E I ~, Updated 4/16/21 5 4. Electric Vehicle Charging A D Residential New construction and major alterations* Please refer to CMC 18.21.140 when completing this section. □ One and two-family residential dwelling or townhouse with attached garage: □ One EVSE Ready parking space required □ Exception : □ Multi-family residential· □ Exception • Total Parking Spaces EVSE Spaces ' Proposed EVSE (10% of total) Installed (50% of EVSE) Other "Ready" Other "Capable" Calculations: Total EVSE spaces= .10x Total parking spaces proposed (rounded up to nearestwhole number) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other may be "Ready" or "Capable" I ' *Majoralterationsare: (1) for one and two-family dwellingsand townhouses with attached garages, alterations have a building permit valuation~ $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation~ $200,000, interior finishes are removed and significant site work and upgrades to, structural and mechanical, electrical, and/or plumbing systems are proposed. *ADU exceptions for EV Ready space (no EV ready space required when): (1) The accessory dwelling unit is located within one-half mile of public transit. (2) The accessory dwelling unit is located within an architecturally and historically significant historic district. (3) The accessory dwelling unit is part of the proposed or existing primary residence or an accessory structure. (4) When on-street parking permits are required but not offered to the occupant of the accessory dwelling unit. (5) When there is a car share vehicle located within one block of the accessory dwelling unit. B. D Nonresidential new construction (includes hotels/motels) □ Exception : ____________ _ Please refer to CMC 18.21.150 when completing this section Total Parking Spaces Proposed EVSE (10% of total) I Installed (50% of EVSE) J Other "Ready" I Other "Capable" I I I Calculation· Refer to the table below· Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces D 0-9 1 1 D 10-25 2 1 D 26-50 4 2 : D 51-75 6 3 • ~ '' D 76-100 9 5 j R I. D 101-150 12 6 . D 151-200 17 9 D 201 andover 10 percent of total 50 percent of Required EV Spaces Calculations: Total EVSE spaces= .10 x Total parking spaces proposed (rounded up to nearestwhole number) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other may be "Ready" or "Capable" Updated 4/ 16/202 I 6 t S. 0Tl'llllepOltatlo Demand Management (TOM): Nonresidential ONLY An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will usethetablebelowbased on yoursubmitted plans todeterminewhetherornoryourpermit requires a TOM plan. If TOM is applicable to your pennit, staff will contact the applicant to develop a site-specific TDM plan based on the permit details. Employee ADT Estimation for Various Commercial Uses Use Office (all)2 Restaurant Retai'3 Industrial Manufacturing Warehousing Emp ADTfor first 1,000 s.f. 20 11 8 4 4 4 EmpADTI 1000 s.f.1 13 11 4.5 3.5 3 1 , Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 1 ()lhEdition 2 For all office uses, use SAN DAG rate of 20 ADT/1 ,000 sf to calculate employee ADT 3 Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration saro01@ c11Gvl1U0os· Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. (8,334 sf I 1,000 x 4.5) + 8 = 46 Employee ADT ~cknowledgment: I acknowledge that the plans submitted may be subject to the City of Cartsbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a TDM plan and understand that an approved TDM plan is a condition of permit issuance. Applicant Signature: _________________ _ Date:. _____ _ • ,-_'?" other than Applicant to be contacted for TDM compliance (if applicable): Name(Printed): _________________ _ Phone Number: ____ _ Email Address: ------------------- ,l. l Updated 4/16/2021 7