Loading...
HomeMy WebLinkAboutDWG 549-9; CT 2024-0001; TYLER STREET HOMES; 01-03CAR L S B A D V I L L A G E D R SITE T Y L E R S T I N T E R S T A T E 5 N.T.S. 86542 03/31/2027 1 TITLE SHEET / NOTES 2 TYLER STREET IMPROVEMENTS 3 DETAILS EG = EXISTING GRADE FS = FINISHED SURFACE FG = FINISHED GRADE FL = FLOWLINE FF = FINISHED FLOOR GF = GARAGE FACE IE = INVERT ELEVATION LA = LANDSCAPE AREA TC = TOP OF CURB TG = TOP OF GRATE ELEVATION RIM = TOP OF RIM ELEVATION EXISTING GRADE FYSB = FRONT YARD SETBACK RYSB = REAR YARD SETBACK SYSB = SIDE YARD SETBACK ABBREVIATION: SDRSD - SAN DIEGO REGIONAL STANDARD DRAWING CMWD - CARLSBAD MUNICIPAL WATER DISTRICT * NOTE: MODIFIED PER CITY OF CARLSBAD STANDARD ** TO BE VERIFIED IN THE FIELD WITH THE R-VALUE TEST THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S):204-010-09-00 THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS: N E ADDRESS: 3215-3225 TYLER STREET, CARLSBAD CA 92008 THE IMPROVEMENT WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS, CURRENT AT THE TIME OF CONSTRUCTION, AS DIRECTED BY THE CITY ENGINEER. PLSA 4070J:\ACTIVE JOBS\4070 NORUM-CARLSBAD-TYLER STREET\CIVIL\DRAWING\IMPROVEMENT PLANS\4070-CV-IP-01-TITLE.DWG 1. CARLSBAD MUNICIPAL CODE 2. CITY OF CARLSBAD ENGINEERING STANDARDS 3. THIS SET OF PLANS 4. RESOLUTION NO __________ DATED ___________ AND NO __________ DATED ___________ 5. THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK) 6. SOILS REPORT AND RECOMMENDATIONS BY GEOTECHNICAL EXPLORATION, INC: JOB. NO. 23-14403 DATED 1/29/2024 7. THE SAN DIEGO REGIONAL STANDARD DRAWINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS. 8. CALIFORNIA COASTAL COMMISSION DEVELOPMENT PERMIT CONDITIONS DATED _________ 9. ENVIRONMENTAL APPROVAL DOCUMENTS DATED________ 10. STORM WATER POLLUTION PREVENTION PLAN (TIER 2) PREPARED BY: ___________ , SEE SHEETS 5-6, DWG 549-9A. 11. STORM WATER QUALITY MANAGEMENT PLAN PREPARED BY: ___________ DATED: _______________ 12. CALIFORNIA STORM WATER QUALITY ASSOCIATION BMP CONSTRUCTION HANDBOOK AND CALTRANS CONSTRUCTION SITE BMP MANUAL PLSA PLSA N/A THE BASIS OF BEARINGS FOR THIS SURVEY IS THE CALIFORNIA COORDINATE SYSTEM, NAD 83 (CCS83) EPOCH 1991.35, ZONE 6, AS DETERMINED LOCALLY BY A LINE BETWEEN FIRST ORDER CONTROL STATIONS "CLSB 130" AND "CLSB 122" BEING A GRID BEARING OF N 63°33'34" E GRID AS DERIVED FROM GEODETIC VALUES SHOWN ON RECORD OF SURVEY 17271, CITY OF CARLSBAD SURVEY CONTROL, FILED ON FEBRUARY 8, 2002 AS FILE NUMBER 2002-0112862 IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY. TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERATED BY FIELD SURVEY METHODS FROM INFORMATION GATHERED ON: JULY 27, 2023 BY: PASCO, LARET, SUITER & ASSOCIATES TOPOGRAPHY SHOWN HEREON CONFORMS TO NATIONAL MAP ACCURACY STANDARDS. IN SOUTHEAST CORNER OF DRAINAGE BOX INLET AT THE END OF CURB RETURN IN THE NORTHEAST CORNER OF GRAND AVENUE AND WASHINGTON STREET, 52 FEET WEST OF RAILROAD TRACKS AND 40 FEET NORTH OF THE CENTER OF GRAND AVENUE. LOT 5 INDUSTRIAL TRACT, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, AS PER MAP 1743, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAID SAN DIEGO COUNTY JANUARY 3, 1923, TOGETHER WITH THAT PORTION OF LOTS 13, 14, 15, AND 16 IN BLOCK "F" OF CARLSBAD ACRE TRACT 106, ACCORDING TO MAP THEREOF NO. 535, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, MAY 2, 1888. ALSO THOSE PORTIONS OF FIRST STREET ADJACENT ON THE NORTHEAST; PINE AVENUE ADJACENT ON THE NORTHWEST; AND THE ALLEY ADJACENT ON THE SOUTHWEST LYING BETWEEN THE NORTHEASTERLY LINE OF THE 200.00 FOOT RIGHT-OF-WAY OF THE ATCHISON TOPEKA AND SANTA FE RAILROAD AND THE SOUTHWESTERLY LINE OF SAID BLOCK "F", AS VACATED BY RESOLUTION OF THE COUNTY BOARD OF SUPERVISORS ON MARCH 1, 1915 IN BOOK 36, PAGE 104 OF MISCELLANEOUS RECORDS, MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT THE NORTHWEST CORNER OF SAID LOT 5, ALSO BEING THE NORTHEASTERLY CORNER OF LOT 4 OF SAID MAP 1743; THENCE, SOUTH 55°27'00" WEST 162.84 FEET ALONG THE SOUTHEASTERLY LINE OF SAID LOT 4 TO A POINT ON A PARALLEL LINE THAT IS 3.00 FEET, MEASURED PERPENDICULAR AND SOUTHWESTERLY OF THE SOUTHWESTERLY LINE OF SAID LOT 5; THENCE, SOUTH 34°33'00" EAST 139.82 FEET TO THE NORTHWESTERLY LINE OF LOT 6 OF SAID MAP 1743; THENCE, NORTH 55°27'00" EAST 162.84 FEET ALONG THE NORTHWESTERLY LINE OF SAID LOT 6 TO THE NORTHEASTERLY CORNER OF LOT 5, ALSO BEING THE SOUTHWESTERLY RIGHT-OF-WAY OF TYLER STREET (FORMERLY FIRST STREET); THENCE, NORTH 34°33'00" WEST 139.82 FEET ALONG SAID SOUTHWESTERLY LINE OF TYLER STREET (FORMERLY FIRST STREET) TO THE POINT OF BEGINNING. X X W W S S G G W S S W W OE OE CARLSBAD GS-26, GS-27 & GS-28 CMWD W-3, W-6 CARLSBAD S-7 1 EA 1 EA 241 LF 140 LF 1,080 SF N/A 847 SF 114 LF PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 CT 2024-0001 "AS BUILT" DATE DATE REVIEWED BY: TYLER STREET HOMES 3215-3225 TYLER STREET 3 549-9 IMP 2024-0010 INSPECTOR MAP 775 MAP 1743 CR 20872 CR 24398 CR 30120 CR 9487 ROS 9309 ROS 14504 ROS 03194 ROS 16439 1. THIS PLAN SUPERSEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD REGARDING IMPROVEMENTS SHOWN ON THIS SET OF PLANS. 2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAIVE ANY PORTION OF THE CARLSBAD MUNICIPAL CODE, RESOLUTION OF CONDITIONAL APPROVAL, CITY STANDARDS OR OTHER ADDITIONAL DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT. THE ENGINEER IN RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE IS DISCOVERED. 3. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER- OF-WORK FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL. 4. A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT OF WAY. PRIOR TO PERMIT ISSUANCE, A CERTIFICATE OF INSURANCE MUST BE FILED NAMING THE CITY OF CARLSBAD AS AN ADDITIONAL INSURED ON THE PERMITTEE'S POLICY IN THE MINIMUM AMOUNT OF $1,000,000.00 FOR EACH OCCURRENCE OF LIABILITY. THE INSURANCE COMPANY WRITING THE POLICY MUST HAVE A RATING OF "A-" OR BETTER AND A SIZE CATEGORY OF CLASS VII OR BETTER AS ESTABLISHED BY "BESTS" KEY RATING GUIDE. 5. NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HAVE BEEN OBTAINED FROM THE CITY AND OTHER APPROPRIATE AGENCIES. 6. REVISION OF THESE PLANS MAY BE REQUIRED IF THE PROPOSED IMPROVEMENTS ARE NOT CONSTRUCTED PRIOR TO THE DEADLINE DATE OF THE IMPROVEMENT AGREEMENT. 7. NO REVISIONS WILL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE CITY ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE APPROPRIATE SHEET OF THE PLANS AND TITLE SHEET. 8. ORIGINAL DRAWINGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING SIGNED BY THE CITY ENGINEER. 9. THE ORIGINAL DRAWING SHALL BE REVISED TO REFLECT AS-BUILT CONDITIONS BY THE ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. 10. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT ALL TIMES DURING CONSTRUCTION. 11. WHERE TRENCHES ARE WITHIN CITY EASEMENTS, A SOILS REPORT COMPRISED OF: (A) SUMMARY SHEET, (B) LABORATORY WORK SHEETS AND (C) COMPACTION CURVES, SHALL BE SUBMITTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. THE SOILS REPORT WILL BE SUBMITTED TO THE CITY ENGINEERING INSPECTOR WITHIN TWO WORKING DAYS OF COMPLETION OF FIELD TESTS. THE WRITTEN FIELD COMPACTION REPORT(S) SHALL BE IMMEDIATELY SUBMITTED TO THE CITY ENGINEERING INSPECTOR UPON COMPLETION OF THE FIELD TESTS. 12.A PRECONSTRUCTION MEETING SHALL BE HELD PRIOR TO THE BEGINNING OF WORK AND SHALL BE ATTENDED BY ALL REPRESENTATIVES RESPONSIBLE FOR CONSTRUCTION, INSPECTION, SUPERVISION, TESTING AND ALL OTHER ASPECTS OF THE WORK. THE CONTRACTOR SHALL SCHEDULE THE MEETING BY CALLING THE INSPECTION LINE AT (760) 438-3891 AT LEAST FIVE (5) WORKING DAYS PRIOR TO STARTING CONSTRUCTION. APPROVED DRAWINGS MUST BE AVAILABLE PRIOR TO SCHEDULING. 13.ALL INSPECTION REQUESTS OTHER THAN FOR PRECONSTRUCTION MEETING WILL BE MADE BY CALLING THE ENGINEERING 24-HOUR INSPECTION REQUEST LINE AT (760) 438-3891. INSPECTION REQUESTS MUST BE RECEIVED PRIOR TO 2:00 P.M. ON THE WORK DAY BEFORE THE INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE. REQUESTS MADE AFTER 2:00 P.M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER. 14. THE OWNER AND/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 15. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL PLAN TO THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING SLOPE OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECTION FROM THE HAZARD OF CAVING GROUND DURING THE EXCAVATION OF SUCH TRENCH OR TRENCHES OR DURING THE PIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5') OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PLAN VARIES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS, TITLE 8 CALIFORNIA ADMINISTRATIVE CODE, THE PLAN SHALL BE PREPARED BY A REGISTERED ENGINEER AT THE CONTRACTORS EXPENSE. A COPY OF THE OSHA EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION. 16. NO BLASTING SHALL BE COMMENCED WITHOUT A CITY ENGINEER APPROVED BLASTING PROGRAM AND BLASTING PERMIT. 17. IF ANY ARCHAEOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK ZONE DURING CONSTRUCTION, OPERATIONS WILL CEASE IMMEDIATELY, AND THE PERMITTEE WILL NOTIFY THE CITY ENGINEER. OPERATIONS WILL NOT RESTART UNTIL THE PERMITTEE HAS RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO DO SO. 18. ALL OPERATIONS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR OPERATION OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED GRADING EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 7:00 A.M. AND 6:00 P.M. EACH DAY, MONDAY THRU FRIDAY AND NO EARTHMOVING OR GRADING OPERATIONS SHALL BE CONDUCTED ON WEEKENDS OR HOLIDAYS. (A LIST OF CITY HOLIDAYS IS AVAILABLE AT THE ENGINEERING DEPARTMENT COUNTER.) 19.ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY INSPECTOR FOR APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING OF WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTE OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 20. IMPORT MATERIAL SHALL BE OBTAINED FROM, AND WASTE MATERIAL SHALL BE DEPOSITED AT, A SITE APPROVED BY THE CITY ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTES OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 21. THE EXISTENCE AND LOCATION OF UTILITY STRUCTURES AND FACILITIES SHOWN ON THE CONSTRUCTION PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. ATTENTION IS CALLED TO THE POSSIBLE EXISTENCE OF OTHER UTILITY FACILITIES OR STRUCTURES NOT SHOWN OR IN A LOCATION DIFFERENT FROM THAT SHOWN ON THE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN ON THE PLANS AND ANY OTHER EXISTING FACILITIES OR STRUCTURES NOT SHOWN. 22. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES ( ABOVEGROUND AND UNDERGROUND ) WITHIN THE PROJECT SITE SUFFICIENTLY AHEAD OF THE CONSTRUCTION TO PERMIT THE REVISIONS OF THE CONSTRUCTION PLANS IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN CONFLICT WITH THE PROPOSED WORK. 23. THE CONTRACTOR SHALL NOTIFY AFFECTED UTILITY COMPANIES (SEE BELOW) AT LEAST TWO FULL WORKING DAYS PRIOR TO STARTING CONSTRUCTION NEAR THEIR FACILITIES AND SHALL COORDINATE WORK WITH A COMPANY REPRESENTATIVE. UNDERGROUND SERVICE ALERT (800)422-4133 SDG&E (800)411-7343 AT&T (800)892-0123 TIME WARNER CABLE (760)438-7741 COX COMMUNICATIONS (619)262-1122 CITY OF CARLSBAD (STREETS AND STORM DRAIN) (760)434-2980 *CITY OF CARLSBAD (SEWER,WATER & RECLAIMED WATER) (760)438-2722 *SAN DIEGUITO WATER DISTRICT (760)633-2650 *LEUCADIA WASTEWATER DISTRICT (760)753-0155 *VALLECITOS WATER DISTRICT (760)744-0460 *OLIVENHAIN WATER DISTRICT (760)753-6466 *BUENA SANITATION DISTRICT (760)726-1340 x1330 *AS APPROPRIATE 24. IN ACCORDANCE THE CITY STORM WATER STANDARDS ALL STORM DRAIN INLETS CONSTRUCTED BY THIS PLAN SHALL INCLUDE "STENCILS" BE ADDED TO PROHIBIT WASTE DISCHARGE DOWNSTREAM. STENCILS SHALL BE ADDED TO THE SATISFACTION OF THE CITY ENGINEER. 1. ACTUAL STRUCTURAL SECTIONS WILL BE DETERMINED AFTER "R" VALUE TESTS HAVE BEEN CONDUCTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, ON THE PREPARED BASEMENT SOIL. THE "R" VALUE TESTS AND THE ENGINEERED STRUCTURAL SECTION MUST BE SUBMITTED TO THE ENGINEERING INSPECTOR FOR REVIEW AND APPROVAL A MINIMUM OF TWO (2) CITY WORKING DAYS BEFORE THE WORK BEGINS. 2. STREET LIGHTS SHALL BE INSTALLED AS SHOWN ON THESE PLANS, UNDERGROUND CONDUIT RUNS, SERVICE POINTS AND HAND-HOLES SHALL BE SHOWN ON THE "AS-BUILT" PLANS. NO DIRECT BURIAL STREET LIGHT FOUNDATIONS WILL BE ALLOWED. ALL LUMINAIRES SHALL BE "CUT OFF" TYPE. 3. ALL UNDERGROUND UTILITIES AND LATERALS SHALL BE INSTALLED PRIOR TO CONSTRUCTION OF CURBS, CROSS GUTTERS OR SURFACING OF STREETS. 4. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. 5. WHEELCHAIR RAMPS SHALL BE INSTALLED PER REQUIREMENTS OF TITLE 24, CALIFORNIA ADMINISTRATIVE CODE. 6. STREET TREES SHALL BE INSTALLED PER SECTION VI OF THE CITY OF CARLSBAD LANDSCAPE MANUAL. 7. FIRE HYDRANT MARKERS SHALL BE PLACED IN THE STREET WITHIN THE LIMITS OF WORK OF THIS PLAN PER SDRS DWG M19. 8. ALL SURVEY MONUMENTS AND POINTS THAT ARE DISTURBED BY THIS WORK SHALL BE REESTABLISHED, PERPETUATED, AND DOCUMENTED PER THE PROFESSIONAL LAND SURVEYORS ACT. 9. TWO (2) SETS OF SURVEY (CUT) SHEETS SHALL BE PROVIDED TO THE CITY ENGINEERING INSPECTOR. 10. STREET LIGHTS SHALL BE 5,500 LUMEN (40 WATT) OR 13,700 PUPIL LUMEN (100 WATT) HIGH EFFICIENCY INDUCTION LIGHTS. 1. SEWER MAIN AND APPURTENANCES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "CITY OF CARLSBAD ENGINEERING STANDARDS (LATEST EDITION), VOLUME 1- GENERAL DESIGN STANDARDS, CHAPTER 6-DESIGN CRITERIA FOR GRAVITY SEWER LINES AND APPURTENANCES, AND VOLUME 3 -STANDARD DRAWINGS AND NOTES AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, LATEST EDITION (GREEN BOOK). 2. BEFORE ANY CONNECTION TO THE CITY'S EXISTING SYSTEM, A PERMIT SHALL BE OBTAINED FROM THE CITY. IT MUST BE SIGNED AND APPROVED BY THE CITY ENGINEER OR DESIGNEE. 3. BEFORE CONSTRUCTION BEGINS IN ANY PUBLIC RIGHT OF WAY, A CITY RIGHT OF WAY PERMIT SHALL BE REQUIRED. 1. WATER & RECYCLED WATER MAIN AND APPURTENANCES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "CITY OF CARLSBAD ENGINEERING STANDARDS" (LATEST EDITION) VOLUMES 2 & 3. 2. BEFORE ANY CONNECTION OR SHUT DOWN OF VALVES ON EXISTING C.M.W.D. LINES, A PERMIT SHALL BE OBTAINED FROM THE C.M.W.D. OFFICE AND MUST BE SIGNED AND APPROVED BY THE CITY OF CARLSBAD'S DEPUTY CITY ENGINEER AND THE UTILITY OPERATIONS' PUBLIC WORKS MANAGER. 3.ALL INSPECTION REQUESTS OTHER THAN FOR PRECONSTRUCTION MEETING WILL BE MADE BY CALLING THE ENGINEERING 24-HOUR INSPECTION REQUEST LINE AT (760) 438-3891. INSPECTION REQUESTS MUST BE RECEIVED PRIOR TO 2:00 P.M. ON THE WORK DAY BEFORE THE INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE. REQUESTS MADE AFTER 2:00 P.M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER. 4. NO TREES OR STRUCTURES SHALL BE ALLOWED IN THE WATER LINE EASEMENT, ALL EXISTING TREES AND STRUCTURES SHALL BE REMOVED PRIOR TO COMMENCEMENT OF WORK - ANY EXCEPTIONS SHALL REQUIRE WRITTEN PERMISSION FROM THE DISTRICT ENGINEER. 5. ALL BURIED COPPER PIPING AND APPURTENANCES SHALL BE PROTECTED BY MEANS OF CATHODIC PROTECTION. IF DEVELOPER/OWNER CONDUCTS A SOILS TEST REPORT AND DEMONSTRATES THAT PROTECTION CAN BE PERFORMED IN ANOTHER MANNER, THE DISTRICT ENGINEER WILL CONSIDER AN ALTERNATIVE FORM OF PROTECTION. 6. THE EXACT HORIZONTAL AND VERTICAL ALIGNMENT AND TYPE OF MATERIALS OF THE FIRE LINE LOCATED BETWEEN THE DETECTOR CHECK VALVE AND BUILDING SHALL BE DETERMINED BY THE CITY OF CARLSBAD FIRE MARSHAL. 7. ALL POTABLE WATER SERVICES SHALL BE 1" AND ALL METERS SHALL BE 1" (UNLESS OTHERWISE NOTED ON PLANS). 8. ALL WATER METER BOXES SHALL BE 17" X 30" X 12" POLYMER CONCRETE AS MANUFACTURED BY ARMORCAST OR EQUAL. 9. MINIMUM SPACING BETWEEN POTABLE WATER SERVICES AND SEWER LATERALS SHALL BE 10 FEET. 10. THE TOP OF WATER METER BOXES SHALL BE FLUSH WITH THE FINISHED SURFACE GRADE. 11. CONSTRUCTION OF WATER MAINS AND RECYCLED WATER MAINS SHALL ADHERE TO THE "CRITERIA FOR THE SEPARATION OF WATER MAINS AND SANITARY SEWERS" PUBLISHED BY THE STATE OF CALIFORNIA'S DEPARTMENT OF HEALTH SERVICES. 12. AXIAL DEFLECTION AT THE PIPE JOINTS IS NOT ALLOWED. THE USE OF A HIGH- DEFLECTION COUPLING AT A PIPE JOINT MAY BE PERMITTED BY THE INSPECTOR ON A CASE BY CASE BASIS NOT TO EXCEED 4 DEGREES TOTAL DEFLECTION PER COUPLING (2 DEGREES/EACH GASKET). USE CERTAINTEED "VINYL-IRON" H.D. FOR C900. 13. BEFORE CONSTRUCTION BEGINS IN ANY PUBLIC RIGHT OF WAY, A CITY RIGHT OF WAY PERMIT SHALL BE REQUIRED. 14. NO CUTTING OR SNAPPING OF ASBESTOS CEMENT PIPE (ACP) IS PERMITTED. CONTRACTOR SHALL REMOVE ACP TO NEAREST COUPLING AND INSTALL ACP X PVC ADAPTORS AND THE NECESSARY PVC SIZE AND CLASS PIPE TO INSTALL THE TEE AT THE STATION. 15. PRIOR TO BACKFILL, INSTALL TRACER WIRE ON TOP OF PIPE AND SECURE IN PLACE WITH 2-INCH WIDE PLASTIC ADHESIVE TAPE AT MAXIMUM 10-FOOT INTERVALS. WIRE TO ENTER VALVE STANDS BY MEANS OF DRILLED HOLE IN PIPE STAND WALL JUST BELOW 4TTBOX. WIRE IS NOT TO INTERFERE WITH VALVE NUT OPERATION. RUN TRACER WIRE CONTINUOUSLY ALONG PIPE AND TERMINATE IN ADJACENT VALVE BOXES FOR BURIED ASSEMBLIES OR BURIED VALVES. WHERE BURIED SPLICES OCCUR, USE AN ELECTRICAL EPOXY RESIN SUCH AS SCOTCHCAST, OR APPROVED EQUAL. PROVIDE 24 INCHES OF COILED WIRE AT ACCESS POINTS FOR ATTACHMENTS OF PIPE LOCATING EQUIPMENT. EACH INSTALLED RUN OF PIPE SHALL BE CAPABLE OF BEING LOCATED USING THE TRACER WIRE. PROTECT WIRE INSULATION FROM DAMAGE DURING INSTALLATION AND BACKFILLING. WIRE INSULATION THAT IS BROKEN, CUT, OR DAMAGED SHALL BE REPLACED. TRACER WIRE SHALL BE AWG NO. 8 STRANDED COPPER WIRE WITH HIGH MOLECULAR WEIGHT POLYETHYLENE (HMW/PE) INSULATION SPECIFICALLY DESIGNED FOR DIRECT BURIAL IN CORROSIVE SOIL OR WATER. POLYETHYLENE INSULATION SHALL CONFORM TO ASTM D 1248, TYPE 1, CLASS C. WIRES WITH CUT OR DAMAGED INSULATION ARE NOT ACCEPTABLE AND REPLACEMENT OF THE ENTIRE WIRE WHICH HAS BEEN DAMAGED WILL BE REQUIRED AT THE CONTRACTOR'S EXPENSE. 16. CONTRACTOR TO SUBMIT E-28 FORM TO CM&I, MINIMUM 2 WEEKS PRIOR TO SCHEDULED WATER SHUTDOWN. 1. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL SIGNING AND STRIPING. 2. SIGNING, STRIPING AND PAVEMENT MARKINGS SHALL CONFORM TO THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (FHWA'S MUTCD LATEST VERSION, AS AMENDED FOR USE IN CALIFORNIA), CALTRANS STANDARD SPECIFICATIONS (2018 OR LATEST VERSION THEREOF), THESE PLANS AND THE SPECIAL PROVISIONS. 3. ALL SIGNING AND STRIPING IS SUBJECT TO THE APPROVAL OF THE TRANSPORTATION DIRECTOR OR HIS REPRESENTATIVE, PRIOR TO INSTALLATION. 4. ANY DEVIATION FROM THESE SIGNING AND STRIPING PLANS SHALL BE APPROVED BY THE ENGINEER OF WORK AND TRANSPORTATION DIRECTOR PRIOR TO ANY CHANGE IN THE FIELD. 5. ALL SIGNING AND STRIPING SHALL BE REFLECTIVE PER CALTRANS SPECIFICATIONS. STRIPING SHALL BE REPAINTED TWO WEEKS AFTER INITIAL PAINTING. SIGNING SHALL USE ENCAPSULATED LENS REFLECTIVE SHEETING (HIGH INTENSITY OR EQUAL). 6. PRIOR TO FINAL ACCEPTANCE OF STREET IMPROVEMENTS, ALL STREET STRIPING AND MARKINGS WITHIN A 500' PERIMETER OF THE CONSTRUCTION PROJECT WILL BE RESTORED TO A "LIKE NEW" CONDITION, IN A MANNER MEETING THE APPROVAL OF THE CITY INSPECTOR. 7. EXACT LOCATION OF STRIPING AND STOP LIMIT LINES SHALL BE APPROVED BY TRANSPORTATION DIRECTOR OR HIS REPRESENTATIVE PRIOR TO INSTALLATION. 8. CONTRACTOR SHALL REMOVE ALL CONFLICTING PAINTED LINES, MARKINGS AND PAVEMENT LEGENDS BY GRINDING. DEBRIS SHALL BE PROMPTLY REMOVED BY THE CONTRACTOR. 9. ALL PAVEMENT LEGENDS SHALL BE THE LATEST VERSION OF THE CALTRANS STENCILS. 10. LIMIT LINES AND CROSSWALKS SHALL BE FIELD LOCATED. CROSSWALKS SHALL HAVE 10' INSIDE DIMENSION UNLESS OTHERWISE SPECIFIED. 11. ALL CROSSWALKS, LIMIT LINES, STOP BARS, PAVEMENT ARROWS AND PAVEMENT LEGENDS SHALL BE THERMOPLASTIC UNLESS OTHERWISE SPECIFIED. 12. FIRE HYDRANT PAVEMENT MARKERS SHALL CONFORM TO THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (FHWA'S MUTCD 2009 LATEST VERSION, AS AMENDED FOR USE IN CALIFORNIA) AND SAN DIEGO REGIONAL STANDARD DRAWING M-19. 13. ALL MEDIAN NOSES AND FLARES SHALL BE PAINTED YELLOW. 14. ALL SIGNS SHALL BE STANDARD SIZE AS SHOWN IN THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (FHWA'S MUTCD 2009 REVISION 1 AND 2, AS AMENDED FOR USE IN CALIFORNIA) UNLESS OTHERWISE SPECIFIED. 15. SIGN POSTS SHALL BE SQUARE PERFORATED STEEL TUBING WITH BREAKAWAY BASE PER SAN DIEGO REGIONAL STANDARD DRAWING M-45. 16. WHEN A SIGN IS ATTACHED TO A POLE, IT SHALL BE MOUNTED USING A STANDARD CITY OF CARLSBAD MOUNTING BRACKET WITH STRAPS. 17. EXISTING SIGNS REMOVED BY THE CONTRACTOR SHALL BE DELIVERED BY THE CONTRACTOR TO THE CITY OF CARLSBAD PUBLIC WORKS YARD AT 405 OAK AVENUE. 18. ALL SIGNS SHOWN ON THESE PLANS SHALL BE NEW SIGNS PROVIDED AND INSTALLED BY THE CONTRACTOR EXCEPT THOSE SIGNS SPECIFICALLY SHOWN AS EXISTING TO BE RELOCATED OR TO REMAIN. 19. (IF NECESSARY) WHERE R4-7 SIGN AND OM1-3 OBJECT MARKER ARE TO BE INSTALLED IN A 2-FOOT WIDE MEDIAN NOSE, THE R4-7 SIGN SHALL BE 18"X24" AND THE OM1-3 OBJECT MARKER SHALL BE 12"X12" 20. ALL NEW AND RELOCATED SIGNS SHALL BE CLEARLY VISIBLE, NOT BLOCKED BY ANY OBSTRUCTION. THE CONTRACTOR IS RESPONSIBLE TO TRIM OR REMOVE ANY VEGETATION BLOCKING NEW AND RELOCATED. I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. BY: DATE: BRYAN A. KNAPP, R.C.E. R.C.E. NO.: REGISTRATION EXPIRATION DATE: FIRM: PASCO, LARET, SUITER, AND ASSOCIATES, INC. ADDRESS: 1911 SAN DIEGO AVE, SUITE 100 CITY, STATE: SAN DIEGO, CA 92110 TELEPHONE: (858) 259-8212 362 1666 DESCRIPTION: CLSB-130, 2.5" DISK LOCATION: RECORDED: ELEVATION: 40.91 DATUM: NGVD29 NAME:JOHN NORUM FOR: TYLER STREET DEV LLC ADDRESS:2888 LOKER AVENUE EAST, SUITE 220 CARLSBAD, CA 92010 PHONE NO.: (949) 678-4927 SDRSD G-2* WCMWD W-4, W-6 1 EA F FCMWD W-9 1 EA CMWD W-17, W-18 1 EAWW WM WM SDRSD G-14A* (WIDTH PER PLAN)205 SF W W 148 LF 280 SF JANUARY 2024 SEE GRADING PLAN DWG 549-9A FOR DESCRIPTION OF ONSITE BMPS TREE WELL SD-A OWNER YES 2-3 INSPECTED MONTHLY MAINTAIN WHEN NEEDED SDRSD G-7 PROPERTY BOUNDARY CENTERLINE OF ROAD PUBLIC RIGHT-OF-WAY EXISTING CONTOUR LINE PROPOSED CONTOUR LINE PROPOSED DIRECTION OF FLOW PROPOSED SAWCUT OF EXISTING PAVEMENT PROPOSED 3" AC GRIND AND OVERLAY PROPOSED 4" AC OVER 6" CLASS II AB** PROPOSED 4" PCC SIDEWALK PROPOSED 6" PCC CURB & GUTTER REMOVE EXISTING CURB & GUTTER PROPOSED TRENCH RESURFACING EXISTING OVERHEAD ELECTRICAL LINE EXISTING FENCE EXISTING WATER MAIN (SIZE PER PLAN) EXISTING SEWER MAIN (SIZE PER PLAN) EXISTING GAS MAIN (SIZE PER PLAN) PROPOSED 8" PUBLIC WATER MAIN UPSIZE IMPROVEMENTS PROPOSED 8"X6" REDUCER PROPOSED 8" GATE VALVES PROPOSED 1" IRRIGATION WATER SERVICE, METER AND BACKFLOW PROPOSED 2" DOMESTIC WATER SERVICE, METER AND BACKFLOW PROPOSED 6" FIRE SERVICE, 6" FIRE RPDA PROPOSED FIRE HYDRANT ASSEMBLY PROPOSED 6" PVC SEWER LATERAL WITH 12" CLEANOUT LID & BACK WATER DEVICE PROPOSED 6" PCC DRIVEWAY APRON PROPOSED TREE WELL BMP 3 EA 3 EA 1 EA 1 140 LF 2025-027 1/28/2025 SDC GS DS GS-1.02 CMWD W-20 CMWD W-21 7527 11/6/2024 4/21/2025 NF NF GENERAL NOTES STREET NOTES SIGNING AND STRIPING NOTES / VICINITY MAP SEWER NOTES INDEX OF SHEETS ABBREVIATION LEGEND REFERENCE DRAWINGS WATER NOTES OWNER/DEVELOPER INFORMATION SOURCE OF TOPOGRAPHY LEGAL DESCRIPTION PROJECT LOCATION BENCH MARK BASIS OF BEARINGS DECLARATION OF RESPONSIBLE CHARGE (SHEETS 1-3) --- '?'<-0 I OJI( f3' ~ ~~DRtw~'-1( '<' ,._ 1< ~-1< /::? 9:-'lo "' Cr)Q:} ..-a--z "' No. 86542 "' u.J "' "' Exp. 03/31/27 =o * * J',t,,!f Cl VI\.. r:t* 't- OF Cf>,\..\~ POST-CONSTRUCTION BMP TABLE STORM WATER REQUIREMENTS THAT APPLY: EXEMPT FROM EXEMPT FROM TRASH CAPTURE1 HYOROMODIFICA TION1 ~ STANDARD STORM WATER REQUIREMENTS ~ YES ~ YES PRIORITY PROJECT REQUIREMENTS NO NO TYPE DESCRIPTION OWNERSHIP MAINTENANCE SHEET NO. MAINTENANCE AGREEMENT FREQUENCY /1, DAlE INITIAL ENGINEER OF WORK REVISION DESCRIPTION I I I WORK TO BE DONE DESCRIPTION LEGEND STD. SYMBOL -------- 64 ----64 ---- (·.·.·.·.·.·.·.·.·.·.·.· .•. •. •.•.•.•.•.•.•.•.•.•.•.•.•.• .•. •. •. j I / / 7 ,' 7 1 7 / 7 ,, /1 fZ 7 7 7 / 71 7 I 7 7 <J ® ~ ►1 ----§ ------0 ~ QUANTITY P L S A It, .. ~ P.E. EXP. PLSAEN GINEE RING.COM I SHEET I CITY OF CARLSBAD I SHEETS I ENGINEERING DEPARlMENT IMPROVEMENT PLANS FOR: TITLE SHEET APPROVED: JASON S. GELOERT ENGINEERING MANAGER RCE 63912 f:¥1>.9/YJ/28 DAlE I PROJECT NO. I DRAWING NO. DAlE INITIAL DAlE INITIAL RVWD BY: DlHER APPROVAL QlY APPROVAL CHKD BY: Docusign Envelope ID: AD6F41AF-0945-4557-A78D-2AB04DAB16AF 5/14/2025 PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 CT 2024-0001 "AS BUILT" DATE DATE REVIEWED BY: TYLER STREET HOMES 3215-3225 TYLER STREET 3 549-9 IMP 2024-0010 INSPECTOR GRAPHIC SCALE: 1" = 10' 0 10'20'30' J:\ACTIVE JOBS\4070 NORUM-CARLSBAD-TYLER STREET\CIVIL\DRAWING\IMPROVEMENT PLANS\4070-CV-IP-02-PLAN AND PROFILE.DWG PLAN VIEW - PUBLIC IMPROVEMENTS SCALE: 1" = 10' PROFILE VIEW - CL TYLER STREET SCALE: 1" = 10' HORIZONTAL; 1" = 4' VERTICAL 36 CL 40 CL 44 CL 48 CL 52 CL 48 TC 44 TC 52 TC 40 TC 36 CL 40 CL 44 CL 48 CL 52 CL 48 TC 44 TC 52 TC 40 TC CONSTRUCTION NOTES 1 2 3 4 5 6 7 8 9 10 11 12 13 14 5+00 5+50 6+00 PROFILE VIEW - TOP OF CURB RIGHT SCALE: 1" = 10' HORIZONTAL; 1" = 4' VERTICAL UTILITIES ARE KNOWN TO EXIST IN THE AREA. INFORMATION SHOWN HEREON IS PER BEST AVAILABLE RECORD INFORMATION. EXACT HORIZONTAL AND VERTICAL LOCATION OF EXISTING UTILITIES UNKNOWN. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO ORDERING MATERIALS AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER OF WORK OF ANY DISCREPANCIES BETWEEN ACTUAL LOCATION AND PLAN LOCATION OF UTILITIES UPON DISCOVERY OF DISCREPANCY ALL EXISTING MONUMENTS TO BE PROTECTED IN PLACE. ANY MONUMENTS DESTROYED DURING CONSTRUCTION SHALL BE REPLACED BY A LICENSED LAND SURVEYOR AND PROPER DOCUMENTATION SHALL BE FILED WITH THE COUNTY RECORDER. ADDITIONAL NOTES 1. ALL UTILITIES SHOWN HEREON PER BEST AVAILABLE RECORD INFORMATION. 2. ONSITE IMPROVEMENTS SHOWN HEREON FOR REFERENCE ONLY; REFER TO SEPARATE PRECISE GRADING PLAN DWG 549-9A FOR CONSTRUCTION 3. EXISTING SEWER LATERALS AND CLEANOUTS COULD NOT BE LOCATED. ANY EXISTING SEWER LATERALS LOCATED DURING CONSTRUCTION SHALL BE REMOVED PER CITY OF CARLSBAD STANDARD SPECIFICATION 15000-3.12. CONTRACTOR TO LOCATE DURING CONSTRUCTION. 4. FOR PRIVATE ONSITE WATER, RECYCLED WATER, FIRE, AND SEWER SEE SEPARATE PRIVATE UTILITY PLAN AND PRIVATE FIRE UNDERGROUND PLAN UNDER SEPARATE PERMIT SUBMITTAL. EASEMENT / DEDICATION NOTES PROPOSED 5.0' WIDE PUBLIC UTILITY EASEMENT AND PUBLIC STREET EASEMENT TO THE CITY OF CARLSBAD 1 EXISTING EASEMENTS NOTES ITEMS 1 THROUGH 3 ARE NON MAPPING ITEMS AND HAVE BEEN OMITTED HEREON. 15 2 *NOTE: DURING CONSTRUCTION EXISTING WATER SERVICES AFFECTED BY WATER MAIN UPSIZE TO REMAIN ACTIVE. CONTRACTOR TO SUBMIT TEMPORARY HIGH LINE WITH SHUT DOWN REQUEST.PVC SEWER LATERAL TABLE CL STATIONING OF LATERAL @ MAIN SIZE MAIN IE IE @ MAIN LENGTH DROP TO MAIN LATERAL ELEV. @ PL (IE) LATERAL SLOPE % GROUND ELEV. @ PL DEPTH BELOW PL (PL TO IE) BACKWATER VALVE REQ'D 5+57.07 6" 38.5 39.7 24.00' 1.20' 40.1'2.0%46.4' 6.3'NO 8" WATER MAIN THRUST / ANCHOR BLOCK TABLE **BEARING AREA (SF)BEND / FITTING APPROX. SIZE **BEARING AREA BASED ON 200 PSI TEST PRESSURE FOR 8" PIPE, SAND AND GRAVEL (1,500 LB/SF) 18.290° 10.4 TEE & DEAD END 4.25' X 4.25' 3.25' X 3.25' 13.0 45° 3.75' X 3.5' EXISTING SURVEY MONUMENT SHALL BE PROTECTED IN PLACE. MONUMENT SHALL BE REPLACED BY A LICENSED LAND SURVEYOR WHO SHALL FILE A CORNER RECORD WITH THE COUNTY IF DISTURBED OR DESTROYED PROPOSED SEWER CLEANOUT WITH CONCRETE BOX AND TRAFFIC RATED LID BY J&R OR BROOKS PART NO. 3-R-T PER CITY OF CARLSBAD STANDARD S-7 PROPOSED 8" SEWER CONNECTION, REFER TO CSD S-7 REMOVE AND REPLACE EXISTING CURB & GUTTER WITH 6" PCC CURB & GUTTER PER SDRSD G-02* PROPOSED 1" IRRIGATION WATER SERVICE, METER AND BLACKFLOW PER CMWD STANDARD W-3, W-6 MAXIMUM IRRIGATION DEMAND 5.6 GPM INSTALL PRESSURE REGULATOR AND SET AT 80 PSI PROPOSED 2" DOMESTIC WATER SERVICE, METER AND BACKFLOW PER CMWD STANDARD W-4, W-6 PROPOSED 6" FIRE SERVICE AND 6" FIRE RPDA (BY WILKINS MODEL 475DA OR APPROVED EQUAL) PER CMWD W-9. INSTALL U.L. LISTED 2-WAY (2 X 2-1/2" INLET) FIRE DEPARTMENT CONNECTION (FDC) BY POTTER ROEMER MODEL 5715-A-DI OR APPROVED EQUAL ON FIRE SERVICE RPDA PROPOSED 20' WIDE PCC DRIVEWAY APRON PER SDRSD G-14A*; SEE DETAIL ON SHEET 3 FOR VEHICLE PCC ROADWAY TYPICAL SECTION PROPOSED TRENCH RESURFACING OF AC PAVEMENT PER CITY OF CARLSBAD STANDARD GS-26, GS-28 PROPOSED TRENCH RESURFACING OF AC PAVEMENT PER CITY OF CARLSBAD STANDARD GS-27, GS-28 PROPOSED 4" PCC SIDEWALK PER SDRSD G-07 PROPOSED 3" AC GRIND AND OVERLAY PROPOSED AC PAVEMENT SAWCUT PER DETAIL ON SHEET 3 INSTALL FIRE HYDRANT ASSEMBLY PER CMWD STANDARD W-17, W-18 PROPOSED TREE WELL BMP PER DETAILS ON SHEET 3 *AS MODIFIED PER CITY OF CARLSBAD STANDARDS X X X 45 45 45 45 X X X XXXXXXXXXXXXXXXXX 5+00 6+00SSSSSSSSSSSSSSSSSSS S S S S S G G G G G G G G G G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W W W IR R IR R IR R IR R W W W W S S S F F F F W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W C WMWM JTJTJTJT JT JT JT JT JTJ T OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE W WW OE OE OE OE OE OE OE OE OE X X X X X X X X X X X X (SEE DWG 549-9A FOR ONSITE IMPROVEMENTS) L3 L2 ST A 4 + 8 0 . 1 7 ~ 1 5 . 0 0 ' R T MA T C H T O E X . T C ; BE G I N I M P R . P C C C & G ; BE G I N C U R B T R A N S I T I O N ; (4 5 . 7 8 T C ) ; ( 4 5 . 6 5 F L ) ST A 6 + 2 0 . 0 7 ~ 1 5 . 0 0 ' R T MA T C H T O E X . T C ; EN D I M P R . P C C C & G ; (4 6 . 4 6 T C ) ; ( 4 5 . 9 7 F L ) ST A 5 + 5 7 . 0 7 ~ 0 . 0 0 ' T (3 8 . 5 I E ) ( N W ) 39 . 7 I E ( S W ) @ L A T 38 . 5 I E I N ( S W ) @ M A I N (3 8 . 5 I E ) ( S E ) ST A 5 + 2 8 . 5 7 ~ 1 0 . 0 0 ' L T CO N N E C T T O P R O P . 8" P V C W A T E R M A I N ST A 5 + 2 3 . 5 7 ~ 1 0 . 0 0 ' L T CO N N E C T T O P R O P . 8" P V C W A T E R M A I N ST A 5 + 2 1 . 5 7 ~ 1 0 . 0 0 ' L T CO N N E C T T O P R O P . 8" P V C W A T E R M A I N ST A 5 + 0 3 . 9 8 ~ 1 0 . 0 0 ' L T CO N N E C T T O P R O P . 8" P V C W A T E R M A I N 756 15 . 0 ' 15 . 0 ' 6. 0 ' 5. 0 ' P U B L I C R O W DE D I C A T I O N 45 . 0 ' ROW ROW ROW RO W TYLER STREET PI N E A V E N U E EX . P O W E R P O L E TO B E P R O T E C T E D IN P L A C E EX. 1.5" GAS PER DWG 402-6 EX. 8" VC SEWER PER DWG 118-9 EX. 6" ACP WATER MAIN PER DWG 402-6 STA 6+20.07 ~10.00' LT CONNECT PROP. 8" PVC TO EX. 6" ACP WATER MAIN SEE CONNECTION DETAIL ON SHEET 3 ST A 4 + 8 0 . 1 7 ~ 1 0 . 0 0 ' L T CO N N E C T P R O P . 8 " P V C TO E X . 6 " A C P W A T E R M A I N SE E C O N N E C T I O N D E T A I L ON S H E E T 3 TY L E R S T R E E T S T A 4 + 8 0 . 2 6 = P I N E A V E N U E S T A 0 + 0 0 . 0 0 0+ 0 0 LOT 6 MAP 1743 LOT 4 MAP 1743 ST A 5 + 0 0 . 0 0 ~ 0 . 0 0 ' T (4 6 . 2 9 F S ) ST A 5 + 5 0 . 0 0 ~ 0 . 0 0 ' T (4 6 . 4 4 F S ) ST A 6 + 0 0 . 0 0 ~ 0 . 0 0 ' T (4 6 . 4 5 F S ) ST A 5 + 3 7 . 0 7 ~ 1 5 . 0 0 ' R T 46 . 2 8 T C ; 4 5 . 7 8 F L ST A 4 + 8 2 . 1 7 ~ 1 5 . 0 0 ' R T EN D C U R B T R A N S I T I O N ; 46 . 1 5 T C ; 4 5 . 6 5 F L EX . W A T E R S E R V I C E A N D ME T E R T O B E R E M O V E D ST A 5 + 4 0 . 0 7 ~ 1 5 . 0 0 ' R T 45 . 8 7 T C ; 4 5 . 7 9 F L 3 ST A 5 + 0 0 . 1 5 ~ 1 0 . 0 0 ' L T PR O P . 8 " T E E EX . W A T E R M E T E R S TO R E M A I N ST A 5 + 6 3 . 0 7 ~ 1 5 . 0 0 ' R T 46 . 3 4 T C ; 4 5 . 8 4 F L ST A 5 + 3 1 . 3 2 ~ 2 1 . 5 0 ' R T 46 . 3 9 F S ST A 5 + 4 0 . 0 7 ~ 2 5 . 0 0 ' R T 46 . 4 8 F S ST A 5 + 6 0 . 0 7 ~ 2 5 . 0 0 ' R T 46 . 5 2 F S ST A 5 + 6 8 . 8 2 ~ 2 1 . 5 0 ' R T 46 . 4 7 F S ST A 4 + 8 0 . 1 7 ~ 2 1 . 5 0 ' R T 46 . 2 7 F S ST A 4 + 9 9 . 0 7 ~ 2 1 . 5 0 ' R T 46 . 3 1 F S ST A 5 + 0 1 . 9 8 ~ 2 1 . 5 0 ' R T 46 . 3 2 F S ST A 5 + 0 5 . 9 8 ~ 2 1 . 5 0 ' R T 46 . 3 3 F S ST A 5 + 8 8 . 6 5 ~ 2 1 . 5 0 ' R T 46 . 5 2 F S ST A 5 + 9 4 . 3 2 ~ 2 1 . 5 0 ' R T 46 . 5 3 F S ST A 6 + 0 1 . 0 7 ~ 2 1 . 5 0 ' R T 46 . 5 5 F S ST A 6 + 0 5 . 0 7 ~ 2 1 . 5 0 ' R T 46 . 5 6 F S ST A 6 + 1 3 . 3 0 ~ 2 1 . 5 0 ' R T 46 . 5 7 F S ST A 6 + 1 7 . 3 0 ~ 2 1 . 5 0 ' R T 46 . 5 8 F S ST A 5 + 5 6 . 0 7 ~ 2 6 . 0 0 ' R T SE W E R C L E A N O U T 46 . 4 R I M ; 4 0 . 1 I E 2. 0 % 46 . 3 5 F S 46 . 3 8 F S 2. 0 % 0. 5 % 0. 5 % 2. 0 % ST A 5 + 0 3 . 9 8 ~ 2 3 . 0 0 ' R T FI R E H Y D R A N T PR O P . BA C K F L O W PR O P . W A T E R ME T E R S ST A 5 + 6 0 . 0 7 ~ 1 5 . 0 0 ' R T 45 . 9 2 T C ; 4 5 . 8 3 F L ST A 5 + 4 0 . 0 7 ~ 2 0 . 5 0 ' R T 46 . 3 9 F S ST A 5 + 6 0 . 0 7 ~ 2 0 . 5 0 ' R T 46 . 4 3 F S 9. 4 % 2. 0 % EX . F H A N D F I R E S E R V . T O B E RE M O V E D A N D R E P L A C E D EX . C & G T O RE M A I N 46 . 5 7 F S 46 . 6 0 F S EX . D W Y T O B E RE M O V E D 2. 0 % 2. 0 % ST A 5 + 5 0 . 0 7 ~ 1 5 . 0 0 ' R T 20 ' D W Y C L EX . C & G T O RE M A I N EX . O V E R H E A D UT I L I T I E S T O RE M A I N 0.23%0.23%0.23%0.23% (0.3%)(0.6%)(0.2%)(0.1%)(0.4%) 1 9 10 9 11 8 11 12 13 4 214 14 9 1 PROP. 8" DR18 PVC WATER MAIN EX. 6" ACP WATER MAIN PER DWG 402-6 9 12 12 N5 6 ° 0 0 ' 4 5 " E 1 6 2 . 8 6 ' N5 6 ° 0 0 ' 0 1 " E 1 6 2 . 8 6 ' N34°00'48"W 139.90' EX . W A T E R M E T E R TO R E M A I N EX . W A T E R M E T E R TO R E M A I N EX . 6 " W A T E R M A I N EX . S E W E R M A N H O L E (4 5 . 9 8 R I M ) (3 9 . 1 3 I E I N ) (3 9 . 0 8 I N O U T ) JO I N T T R E N C H B Y S E P A R A T E PE R M I T S H O W N F O R R E F . O N L Y EX . S T R I P I N G TO R E M A I N EX . D W Y T O BE R E M O V E D EX . D W Y T O RE M A I N *R E P L A C E E X . W A T E R SE R V I C E U P T O M E T E R *R E C O N N E C T EX . W A T E R SE R V I C E T O PR O P . W A T E R MA I N 4.2 ' 4 . 2 ' 5. 0 ' 4 PR O P . BA C K F L O W EX. BUILDING TO REMAIN ST A 4 + 9 0 . 9 5 ~ 1 8 . 0 0 ' R T TR E E W E L L 15 LOT 20 BLOCK 31 MAP 775 3246 TYLER STREET LOT 17-19 BLOCK 31 MAP 775 515 PINE AVENUE ST A 5 + 0 0 . 1 5 ~ 1 8 . 0 0 ' L T CO N N E C T P R O P . 8 " P V C TO E X . 6 " W A T E R M A I N PROP. 8" DR18 PVC WATER MAIN 9 9 L5 REMOVE EX. 6" ACP WATER MAIN 3. 0 ' 1 ST A 4 + 8 2 . 8 3 ~ 2 1 . 5 0 ' R T 46 . 2 8 F S ST A 6 + 2 0 . 0 7 ~ 2 1 . 5 0 ' R T 46 . 5 9 F S L4 L6 EX . W A L L T O B E RE M O V E D EX . W A L L T O B E RE M O V E D 12 12 12 RE M O V E A N D R E P L A C E E X . CU R B , G U T T E R & S W F R O M NE A R E S T J O I N T T O J O I N T PE R G - 1 1 (0.4%)(0.3%)(0.1%)(0.2%)(0.6%)EG @ CL EXIST. 6" ACP WATER MAIN PER DWG 402-6 PROP. 8" DR18 PVC WATER MAIN EXIST. 6" ACP WATER MAIN PER DWG 402-6 EXIST. 8" VC SEWER MAIN @ 0.37% PER DWG 118-9 APPROX. EXISTING 1.5" GAS MAIN (4 6 . 2 9 F S ) ST A 5 + 0 0 . 0 0 (4 6 . 4 4 F S ) ST A 5 + 5 0 . 0 0 (4 6 . 4 5 F S ) ST A 6 + 0 0 . 0 0 ST A = 4 + 8 0 . 1 7 CO N N E C T P R O P . 8 " P V C TO E X . 6 A C P W A T E R M A I N SE E C O N N E C T I O N D E T A I L ON S H E E T 3 42 . 6 T P ( V E R I F Y ) ST A = 5 + 0 0 . 1 5 RE P L A C E E X . T E E W I T H 8" X 8 " X 8 " T E E 42 . 7 T P ST A = 5 + 0 3 . 9 9 RE M O V E A N D RE P L A C E E X . F H AN D F I R E S E R V I C E 42 . 6 T P ST A = 5 + 2 3 . 5 7 PR O P . 1 " I R R I G A T I O N SE R V I C E 42 . 5 T P ST A = 5 + 2 1 . 5 7 PR O P . 2 " D O M E S T I C SE R V I C E 42 . 5 T P ST A = 5 + 2 8 . 5 7 PR O P . 6 " F I R E SE R V I C E 42 . 7 T P ST A = 5 + 5 7 . 0 7 PR O P . 8 " W Y E CO N N E C T I O N (3 8 . 5 I E ) ( N W ) 39 . 7 I E ( S W ) @ L A T 38 . 5 I E I N ( S W ) @ M A I N (3 8 . 6 I E ) ( S E ) ST A = 6 + 2 0 . 0 7 CO N N N E C T P R O P . 8 " P V C TO E X . 6 " A C P W A T E R M A I N SE E C O N N E C T I O N D E T A I L ON S H E E T 3 42 . 9 T P ( V E R I F Y ) 14 7 6 5 3 ST A = 6 + 1 5 . 2 6 RE P L A C E E X . W A T E R SE R V I C E U P T O M E T E R 42 . 7 T P ( V E R I F Y ) ST A = 5 + 6 5 . 2 6 RE C O N N E C T E X . W A T E R SE R V I C E T O P R O P . WA T E R M A I N 42 . 6 T P ( V E R I F Y ) 3. 5 ' M I N ST A = 5 + 5 0 . 0 0 42 . 9 T P ST A = 6 + 0 0 . 0 0 42 . 9 T P ST A = 5 + 0 0 . 0 0 42 . 7 T P PROPOSED TOP OF CURB PROPOSED FLOW LINE EXISTING TOP OF CURB EXISTING FLOW LINE EXISTING TOP OF CURB ST A = 4 + 8 0 . 1 7 MA T C H T O E X . T C ; BE G I N I M P R . P C C C & G ; BE G I N C U R B T R A N S I T I O N ; (4 5 . 7 8 T C ) ; ( 4 5 . 6 5 F L ) ST A = 4 + 8 2 . 1 7 EN D C U R B T R A N S I T I O N 46 . 1 5 T C ; 4 5 . 6 5 F L ST A = 5 + 3 7 . 0 7 46 . 2 8 T C ; 4 5 . 7 8 F L ST A = 5 + 4 0 . 0 7 45 . 8 7 T C ; 4 5 . 7 9 F L ST A = 5 + 6 0 . 0 7 45 . 9 2 T C ; 4 5 . 8 3 F L ST A = 5 + 6 3 . 0 7 46 . 3 4 T C ; 4 5 . 8 4 F L ST A = 5 + 0 0 . 0 0 (4 6 . 0 6 T C ) 46 . 2 0 T C ST A = 5 + 5 0 . 0 0 (4 6 . 2 5 T C ) ST A = 6 + 0 0 . 0 0 (4 6 . 1 7 T C ) 46 . 4 2 T C ST A = 5 + 5 0 . 0 7 20 ' D W Y C L 45 . 9 0 T C ; 4 5 . 8 1 F L 0.23%0.23% 0.23% ST A = 6 + 2 0 . 0 7 MA T C H T O E X . T C ; EN D I M P R . P C C C & G ; (4 6 . 4 6 T C ) ; ( 4 5 . 9 7 F L ) ST A = 5 + 7 8 . 1 4 46 . 6 8 T C ; 4 5 . 7 8 F L ST A = 4 + 9 0 . 9 5 PR O P O S E D C U R B C U T 46 . 1 7 T C ; 4 5 . 6 7 F L CURB DATA TABLE LINE # / CURVE # L2 L3 LENGTH 56.90 57.00 BEARING/DELTA N34°00'48"W N34°00'48"W RADIUS REMARKS 6" G-2 PCC C&G 6" G-2 PCC C&G CENTERLINE DATA TABLE LINE # / CURVE # 1 LENGTH 1439.89 BEARING/DELTA N34°00'48"W RADIUS WATER MAIN DATA TABLE LINE # / CURVE # L4 L5 L6 LENGTH 119.92 8.00 19.98 BEARING/DELTA N34°00'48"W N55°59'12"E N34°00'48"W RADIUS REMARKS 8" DR18 PVC 8" DR18 PVC 8" DR18 PVC NF NF ' ' ' ' ---- I ' ' ' -~ -~ I I t--+---+--+--+-+--+-- I I ' ' I ' ' ' I ' I ' I I ' I I I ' I I I I ---0 ----I 0 Q_ I --+---+--+-+--+--+---+1--+--+--+-+--+--+--+-+--+--+--+ I I I -- I I , 0 1 ---- ' I I ' - -_,_ I I ' I ' I ' I I ' I ' ' - - - I I - - I I 1___1_ I I I I ~ ----- - - - -1--H -1--1-----+-----+--+ - I I --+-----+---+--+--+--+- +-7 ~ :+--:t--+---+--+--+-~ ---1--~ -~ --1--~ •--t~ '\. I i~---+ ,-I-',-~ \ \ I f I I '-\ LLLLLLLLLLLLYLL LLLLLLLLLLLLLLLLLLL ~ t l l l t t t t t ---+---!--+--+--+--+-- I I +---+1--+--+--+-+---+--+--+--+-+-t-r-+--+-+--+---+-·- --r--r------ --, --- - --I-------I---, --- - - ---I----I--I----r------ - - - - ----I---- I ---- - -- -I---1--I---- +---+---+--+--+-+--+--+--+-+--+--+-- - - - -I--+---+---+ - ---f--+---+---+--+-+--+--+ - • -I---I--I---""" +--+---+ -------+--+---+---+--+--+-+--+--+--+-+--+--+---+1--+--+--+-+--+--+--+-+--+--+---+---+--+--+--+-+--+-- I I I I I ' ' r I I t--+---+--+--+-+----+---+--+--+-+-----+---+--+--+-+-~ ---+---+-----+-----+--+--+-+--+-,____,_ ,__ ,__ 1---+---!~~, - - - - ----+---+--+--+-+----+---+--+--+-+-----+--+----+---+--+--+-+----+---+--+--+-+--+-----+--+--+--+-·- /) I t t I I I - t ---+---+--+--+-+----+---+--+--+-+--+-----+-~-+-----+---+--+--+-+----+---+--+--+-+--+-----+--+--+--+-- I I I I --+--+--t--+---+--+--+--+----+--+--+--+-+--+-----+-+--+--+-·- -+--+--+--+-+-+-----+---+--+--+-t--+--t--+---+--+--+--+----+--+--+--+-+--+-----+-+--+--+-- I I +----+--+---+---+--+--+-+-r-r--+--+--+-+-t-+-+--+---+-+-+-------<-+--+--+--+----+---+-+--+---+---+--+--+--+-+-+-----+-+--+--+-·- t--+---+-+--+-+---+---+--+-- - - -t-14--,__ ,__ ,__ >-->-->--+-----+-+--+--+---+--+--,__ ,__ ,__ >-->-->--- -- ----+--1----,__ ,__ ,__ >-->-->--r--- - -+--+--+--+-t-,,_ ,__ ,__ >-->-->--+---!--+--+--+--+-- --t--t--t-----+---+---+--+--+--+--+--+--+-t--t--t--n - ' \ / +---+---+--+--+-+--+--+-_,_ - I _._ \ r ~ _ _/ 1j Lj t -t -t-------1-1 \ - -f--tl--t--+-\\ t-t---r r ,, I t I I -+---+I--+--+-+--,i'\. -t--t--r --+---+---+--+-+--+-• - J ~ --+---+---+--+-+--+-- I I ----~ -----+---+----------+----------•---+--+-----------------+-----+------------+-------<---+--+--+--+-·- t--+---+--+--+-+----+---+--+--+-+-----+---+--+--+--+--+--+-1-----+-----+--+--+-+----+---+--+----+--1-1----!--- ----+---+--+--+-+----+---+--+--+-+--+-----+-~-+-----+---+--+--+-+----+--+--+--+-+--+-----+--+--+--+-- I I -+--+-----+---!---+--+-+--+--+-+-+---!-1--1--1----+--+-- ----+---+-+--+--+----+---+--+--+-+--+-----+--+--- I I --+--+--t--+---+-+--+--+----+--+--+--+-+--+-----+-+--+--+-·- t--+---+--+--+-+----+--+--+--+-+-----+---+-+--+--+---t--+-1-----+---!---+--+-+--+-- - -1--1--1--1---+---!--- - - - - -t--+---+--+--+-+----+--+--+--+-+-~-+--t--+---+-+--+--+----+--+--+--+-+--+-----+-+--+-+--- j A , I ' I I --· ( I I 0 f'-----k I --- I I I' ~ - ____,.. ' I' r' A 11'1 '/~' '·~-----4 i;.........;... \ \ \ \ \ \ > > > > ' □ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 □ 0 PL S A lfi~ PLSAEN GINEERING.COM P.E. __ _ EXP---- I SHEET I CITY OF CARLSBAD I SHEETS I 1----+----+--------------+--1--t---,1----+----1 ENGINEERING DEPARlMENT 1----+----+--------------+--1--+---,1----+----I 1------+----+--------------+----+---<>----+----1 IMPROVEMENT PLANS FOR: TITLE SHEET 1----+----+--------------+--1--t---,1----+----1 APPROVED: JASON S. GELOERT ENGINEERING MANAGER RCE 63912 f:¥1>.9/YJ/28 DAlE DAlE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DAlE INITIAL DAlE INITIAL RVWD BY: ---1 I PROJECT NO. I DRAWING NO. >-D_lH_ER_N'~PRO'l--AL--+--a-lY-APPR~-OV_AL_, CHKD BY: .__ ______ . ._ __ ___. Docusign Envelope ID: AD6F41AF-0945-4557-A78D-2AB04DAB16AF 5/14/2025 6" PCC C&G PER SDRSD G-2 STREET FLOW COMPACTED SUBGRADE 9.0' LIMITS OF STRUCTURAL SOIL ROOT BARRIER PER SDRSD L-6 30 MIL PLASTIC IMPERMEABLE LINER 48" DEEP STRUCTURAL SOIL COMPACTED TO 95%; STRUCTURAL PER A-1 STRUCTURAL SOIL OR APPROVED EQUAL DEEP ROOT TREE BUBBLER PER SDRSD DWG I-4 UNCOMPACTED SUBGRADE 3" MIN MULCH LAYER 4" OPENING FOR DRAINAGE 30 MIL PLASTIC IMPERMEABLE LINER SPLASH PAD PER SDC GS DS GS-5.06 2"8" PCC SIDEWALK PER SDRSD G-7 4.0' TREE GRATE FRAME #4 X 8" SMOOTH DOWELS @ 18" OC, GREASED ON ONE END, TYP. ALL SIDES PER SDC GS DS GS-1.00 #4 @ 18" O.C. BOTH WAYS PER SDC GS DS GS 1-.00 CURB CUT PER DETAIL THIS SHEET 6' X 4' COHO TREE GATE FRAME WITH COATED IRON IN MATT BLACK FINISH BY URBAN ACCESSORIES; INSTALL GRATE PER MANUFACTER'S SPECIFICATIONS 6" SAND FILTER LAYER ROOT BARRIER PER SDRSD L-6 9" X 30" PCC TREE GRATE SUPPORT, TYP. 3" R/W INSTALL 30 MIL PLASTIC IMPERMEABLE LINER 5.0'4.5' 0.5' SEAL PLASTIC LINER TO ADJACENT IMPROVEMENTS AND EDGE RESTRAINTS PER SDC GS DS GS-5.15 *6.0" THICK PORTLAND CEMENT CONCRETE PER GEOTECH REPORT 6" SUBGRADE TO BE COMPACTED TO AT LEAST 95% RELATIVE COMPACTION PER GEOTECH REPORT *PAVEMENT SECTION TO BE VERIFIED BY PROJECT GEOTECHNICAL ENGINEER BASED ON FIELD TESTED R-VALUE ROWCLPL 5.0' ROW DEDICATION 3.5' 6.0'5.0'15.0'15.0' 45.0' 2.0%(1-2%)(1-2%)(3-4%) PROPOSED AC PAVEMENT SAWCUT EX. 6" PCC CURB AND GUTTER PROP. 4" PCC SIDEWALK PER SDRSD G-07 PROP. 6" PCC CURB AND GUTTER PER SDRSD G-02 EX. 4" PCC SIDEWALK PROP. 8" DR 18 PVC WATERMAIN EX. 8" VC SEWER MAIN PER DWG 118-9 EX. 1.5" GAS PER DWG 402-6 PL EX.PROP. 0.5' 3.5' GU T T E R L I N E SA W C U T L I N E 3.0' MIN 2.0' MIN 6" PCC CURB & GUTTER PER SDRSD G-02 STRUCTURAL SECTION 4" AC OVER 6" CLASS II AB OVER NATIVE SUBGRADE COMPACTED TO 95% REL. COMP. COLD PLAN AND OVERLAY (3" MIN. DEPTH) TO PROVIDE SMOOTH TRANSITION EXISTING AC PAVEMENT 0.5' ROOT BALL 10.0' LIMITS OF STRUCTURAL SOIL 6" SAND FILTER LAYER ROOT BARRIER PER SDRSD L-6 30 MIL PLASTIC IMPERMEABLE LINER 48" DEEP STRUCTURAL SOIL COMPACTED TO 95%; SOIL PER A-1 STRUCTURAL SOIL OR APPROVED EQUAL DEEP ROOT TREE BUBBLER PER SDRSD DWG I-4UNCOMPACTED SUBGRADE 8" ROOT BARRIER PER SDRSD L-6 3" MULCH 7.0' 6.0' TREE GRATE FRAME 9" X 30" TREE GRATE SUPPORT #4 X 8 SMOOTH DOWELS @ 18" OC, GREASED ON ONE END, TYP. ALL SIDES PER SDC GS DS GS-1.02 #4 @ 18" O.C. BOTH WAYS PER SDC GS DS GS-1.02 INSTALL 30 MIL PLASTIC IMPERMEABLE LINER 6' X 4' COHO TREE GATE FRAME WITH COATED IRON IN MATT BLACK FINISH BY URBAN ACCESSORIES; INSTALL GRATE PER MANUFACTURE'S SPECIFICATIONS 3" PCC SIDEWALK PER SDRSD G-7 9" X 30" PCC TREE GRATE SUPPORT, TYP. 30 MIL PLASTIC IMPERMEABLE LINER PCC SIDEWALK PER SDRSD G-7 SEAL PLASTIC LINER TO ADJACENT IMPROVEMENTS AND EDGE RESTRAINTS PER SDC GS DS GS-5.15 PCC CURB & GUTTER (SIZE PER PLAN) PCC CURB & GUTTER (SIZE PER PLAN) B B A A 18" WIDE CURB CUT CENTERED ON TREE WELL SPLASH PAD PER GS-5.06 15' DIAMETER CANOPY STREET TREE WITH 354 CF MIN STRUCTURAL SOIL 9" X 30" TREE GRATE SUPPORT, SEE SECTION B-B BELOW 6' X 4' COHO TREE GATE FRAME WITH COATED IRON IN MATT BLACK FINISH BY URBAN ACCESSORIES; INSTALL GRATE PER MANUFACTURE'S SPECIFICATIONS; TO BE ADA COMPLIANT FOR PEDESTRIAN CIRCULATION CONSTRUCT CONTIGUOUS PCC SIDEWALK LIMITS OF STRUCTURAL SOIL BELOW (4' DEEP X 10' X 9') 6.2' GUTTER LIP R/W TOP OF 6" PCC C&G TOP OF 6" PCC C&G 4.5' FLOWLINE (PER PLAN) FLOWLINE (PER PLAN) 1" GUTTER DEPRESSION @ TREE WELL1" VERTICAL GUTTER TRANSITION OVER 1' HORIZONTAL 1.5' CURB CUT OPENING 1.0' 1.0' 7" 2.5' 6" 6" PCC C&G PER SDRSD G-2 STREET FLOW COMPACTED SUBGRADE CURB CUT PER DETAIL THIS SHEET 30 MIL PLASTIC IMPERMEABLE LINER 9" X 30" PCC TREE GRATE SUPPORT SPLASH PAD PER GS-5.06 ROOT BARRIER PER SDRSD L-6 SEAL PLASTIC LINER TO ADJACENT IMPROVEMENTS AND EDGE RESTRAINTS PER SDC GS DS GS-5.15 9" x 30" x 12" DEEP TYPE 1 SPLASH PAD PER SDC DS GS-5.06 (NO. 2 COARSE AGGREGATE ROCK) R=6" (TYP.) FACE OF CURB LINEGUTTER LIP 2 . 5 ' 1 . 0 ' 1 . 0 ' A A B B 18" CURB CUT OPENING CENTERED AT TREE WELL LOCATION AS SHOWN ON SHEET 2 GUTTER LIP 4 . 5 ' G U T T E R D E P R E S S I O N FACE OF CURB LINE VALL E Y VA L L E Y WWWWW PVC C900 CL235 SPOOL W/ TRANSITION COUPLING. CHASE TO NEAREST JOINT. NO CUTTING ON ACP. 5' MINIMUM. EXISTING 6" A.C. WATER MAIN PER DWG 402-6 INSTALL 8"X6" REDUCER (FLXMJ) W/ THRUST ANCHOR PER CMWD W-20 EXISTING 6" A.C. WATER MAIN PER DWG 402-6 PVC C900 CL235 SPOOL W/ TRANSITITION COUPLING. CHASE TO NEAREST JOINT. NO CUTTING ON ACP. 5' MINIMUM. INSTALL 8"X6" REDUCER (FLXMJ) W/ THRUST ANCHOR PER CMWD W-20 REMOVE EX. 6" GV AND REPLACE WITH 8" FLxPO GV 5' MIN 5' MIN REMOVE EX. TEE AND REPLACE WITH 8" X 8" X 8" FL X FL TEE W/ THRUST BLOCK PER CMWD W-19 REMOVE EX. 6" GV AND REPLACE WITH 8" FLxPO GV REMOVE AND REPLACE EX. FIRE SERVICE & HYDRANT W EX. 6"WATER MAIN REMOVE EX. 6" GV AND REPLACE WITH 8" FLxFL GV 5' M I N W PVC C900 CL235 SPOOL W/ TRANSITION COUPLING. CHASE TO NEAREST JOINT. NO CUTTING ON ACP. 5' MINIMUM. INSTALL 8"X6" REDUCER (FLXMJ) W/ THRUST ANCHOR PER CMWD W-20 J:\ACTIVE JOBS\4070 NORUM-CARLSBAD-TYLER STREET\CIVIL\DRAWING\IMPROVEMENT PLANS\4070-CV-IP-03-DETAILS.DWG PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 CT 2024-0001 "AS BUILT" DATE DATE REVIEWED BY: TYLER STREET HOMES 3215-3225 TYLER STREET 3 549-9 IMP 2024-0010 INSPECTOR PLAN VIEW - TREE WELL MODIFIED SDC GS DS GS-1.02 NOT TO SCALE SECTION A-A - TREE WELL MODIFIED SDC GS DS GS-1.02 NOT TO SCALE SECTION B-B - TREE WELL MODIFIED SDC GS DS GS-1.02 NOT TO SCALE PLAN VIEW - CURB CUT @ TREE WELL SDC GS DS GS-5.01 NOT TO SCALE SECTION A-A - CURB CUT @ TREE WELL SDC GS DS GS-5.01 NOT TO SCALE SECTION B-B - CURB CUT @ TREE WELL SDC GS DS GS-5.01 NOT TO SCALE TYPICALSECTION - VEHICLE PCC ROADWAY NOT TO SCALE TYPICAL DETAIL - AC PAVEMENT SAWCUT NOT TO SCALE TYPICAL SECTION - TYLER STREET NOT TO SCALE TYPICAL DETAIL - WATER CONNECTION DETAIL NOT TO SCALE 3 NF NF L •••••••••••• LP,~J-1 tJ ~-~-_,_____I _1_ r--71 f--------T~-~ _L __ 7 - - /!, I I I I I I I I ________ J 61 6 I - I-I I t> \ ~------t--------------+--11 -I " " " < ' ,1 ·q ,1 q I I I I • •. q L PL S A I■ a, PLSAENGINEERING.COM P.E.--EXP---- I SHEET I CITY OF CARLSBAD I SHEETS I ~===~~===~=========================t===~t===t===j===j ENGINEERING DEPARlMENT t---+---+-------------+-~I---J---1----1 IMPROVEMENT PLANS FOR: TITLE SHEET 1--+-+-------------+-----lf--1---l---1 APPROVED: JASON S. GELOERT ENGINEERING MANAGER RCE 63912 f:¥1>.9/YJ/28 DAlE DAlE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DAlE INITIAL DAlE INITIAL RVWD BY: --1 DlHER APPROVAL a1Y APPROVAL CHKD BY: PROJECT NO. I DRAWING NO. Docusign Envelope ID: AD6F41AF-0945-4557-A78D-2AB04DAB16AF 5/14/2025