HomeMy WebLinkAboutDWG 549-9A; CT 2024-0001; TYLER STREET HOMES; 01-09CAR L S B A D V I L L A G E D R SITE T Y L E R S T I N T E R S T A T E 5 J:\ACTIVE JOBS\4070 NORUM-CARLSBAD-TYLER STREET\CIVIL\DRAWING\GRADING PLANS\4070-CV-GP-01-TITLE.DWG N.T.S. CUT: FILL: IMPORT: EXPORT: REMEDIAL: 2,108 CY (DEPTH OF 2.5 FEET) CY CY CY CY THE BASIS OF BEARINGS FOR THIS SURVEY IS THE CALIFORNIA COORDINATE SYSTEM, NAD 83 (CCS83) EPOCH 1991.35, ZONE 6, AS DETERMINED LOCALLY BY A LINE BETWEEN FIRST ORDER CONTROL STATIONS "CLSB 130" AND "CLSB 122" BEING A GRID BEARING OF N 63°33'34" E GRID AS DERIVED FROM GEODETIC VALUES SHOWN ON RECORD OF SURVEY 17271, CITY OF CARLSBAD SURVEY CONTROL, FILED ON FEBRUARY 8, 2002 AS FILE NUMBER 2002-0112862 IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY. TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERATED BY FIELD SURVEY METHODS FROM INFORMATION GATHERED ON: JULY 27, 2023 BY: PASCO, LARET, SUITER & ASSOCIATES TOPOGRAPHY SHOWN HEREON CONFORMS TO NATIONAL MAP ACCURACY STANDARDS. 1. ACTUAL STRUCTURAL SECTIONS WILL BE DETERMINED AFTER "R" VALUE TESTS HAVE BEEN CONDUCTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, ON THE PREPARED BASEMENT SOIL. THE "R" VALUE TESTS AND THE ENGINEERED STRUCTURAL SECTION MUST BE SUBMITTED TO THE ENGINEERING INSPECTOR FOR REVIEW AND APPROVAL A MINIMUM OF TWO (2) CITY WORKING DAYS BEFORE THE WORK BEGINS. 2. STREET LIGHTS SHALL BE INSTALLED AS SHOWN ON THESE PLANS, UNDERGROUND CONDUIT RUNS, SERVICE POINTS AND HAND-HOLES SHALL BE SHOWN ON THE "AS-BUILT" PLANS. NO DIRECT BURIAL STREET LIGHT FOUNDATIONS WILL BE ALL LUMINAIRES SHALL BE "CUT OFF" TYPE ALLOWED. 3. ALL UNDERGROUND UTILITIES AND LATERALS SHALL BE INSTALLED PRIOR TO CONSTRUCTION OF CURBS, CROSS GUTTERS OR SURFACING OF STREETS. 4. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. 5. WHEELCHAIR RAMPS SHALL BE INSTALLED PER REQUIREMENTS OF TITLE 24, CALIFORNIA ADMINISTRATIVE CODE. 6. STREET TREES SHALL BE INSTALLED PER SECTION VI OF THE CITY OF CARLSBAD LANDSCAPE MANUAL. 7. FIRE HYDRANT MARKERS SHALL BE PLACED IN THE STREET WITHIN THE LIMITS OF WORK OF THIS PLAN PER SDRSD DWG M19. 8. ALL SURVEY MONUMENTS AND POINTS THAT ARE DISTURBED BY THIS WORK SHALL BE REESTABLISHED, PERPETUATED, AND DOCUMENTED PER THE PROFESSIONAL LAND SURVEYORS ACT. 9. TWO (2) SETS OF SURVEY (CUT) SHEETS SHALL BE PROVIDED TO THE CITY ENGINEERING INSPECTOR. 10. STREET LIGHTS SHALL BE 5,500 LUMEN (40 WATT) OR 13,700 PUPIL LUMEN (100 WATT) HIGH EFFICIENCY INDUCTION LIGHTS. THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S):206-010-09-00 THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS: N_____________ E________________ (CCS 83) ADDRESS: 3215-3225 TYLER STREET, CARLSBAD, CA 92008 *NOTE: QUANTITIES WITHIN / SUBSET OF DISTURBED AREA SIGNATURE DATE I (WE) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER-ALL GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF THIS SITE. I (WE) ALSO UNDERSTAND AND ACKNOWLEDGE THAT I (WE) MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPs) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND SIGNED OFF BY THE CITY OF CARLSBAD. IF THIS PROJECT/DEVELOPMENT IS SUBJECT TO A STATE-REGULATED SWPPP, I (WE) ALSO AGREE A QUALIFIED SWPPP PRACTITIONER (QSP) HAS BEEN OR WILL BE RETAINED TO SUPERVISE IMPLEMENTATION OF THE SWPPP IN ACCORDANCE WITH THE CALIFORNIA CONSTRUCTION ORDER AND MUNICIPAL PERMIT, LATEST VERSION. JOHN NORUM FOR: TYLER STREET DEV LLC 1 TITLE SHEET / NOTES 2 DEMOLITION PLAN 3 GRADING PLAN 4 SECTIONS AND DETAILS 5 DETAILS 6 DETAILS 7 TIER 2 SWPPP COVER SHEET 8 TIER 2 SWPPP 9 SINGLE SHEET BMP THE GRADING WORK SHALL CONSIST OF THE CONSTRUCTION OF ALL CUTS AND FILLS, REMEDIAL GRADING, DRAINAGE FACILITIES, EROSION CONTROL FACILITIES, AND PLANTING OF PERMANENT LANDSCAPING AND PREPARATION OF AS-BUILT GRADING PLANS, AS-BUILT GEOLOGIC MAPS AND REPORTS, ALL AS SHOWN OR REQUIRED ON THIS SET OF PLANS AND THE CITY STANDARDS, SPECIFICATIONS, REQUIREMENTS, RESOLUTIONS AND ORDINANCES CITED ON THESE PLANS. THE GRADING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS, CURRENT AT THE TIME OF CONSTRUCTION, AS DIRECTED BY THE CITY ENGINEER. *AS MODIFIED BY CITY OF CARLSBAD STANDARDS 3215-3225 TYLER STREET CARLSBAD, CA 92008 APN: 204-010-09-00 0 1,740 1,740 0 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT JOHN NORUM AT (949) 678-4927, 24 HOURS A DAY. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY DEVICES WHEN RAIN IS EMINENT. 3. FOR PROJECTS COVERED BY STATE SWPPP/WDID, IN ACCORDANCE WITH THE CONSTRUCTION ORDER ISSUED BY THE CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD, THE QUALIFIED SWPPP PRACTITIONER (QSP) SHALL UPDATE AND MAINTAIN THE WATER POLLUTION CONTROL PLAN (WPCP) TO ADDRESS UPDATED SITE CONDITIONS OF THE PROJECT. THE UPDATED WPC PLAN AND UPDATED SWPPP SHALL BE KEPT AT THE PROJECT SITE AND MADE AVAILABLE TO THE CITY INSPECTOR. ADDITIONAL CONSTRUCTION BMP'S BEYOND THE ORIGINAL APPROVED SWPPP SHALL BE PROVIDED TO ADDRESS SITE CONDITIONS NOT ANTICIPATED. THE QSP SHALL REPORT BMP DEFICIENCIES TO THE CITY INSPECTOR. THE QSP SHALL OBTAIN APPROVAL FROM THE QUALIFIED SWPPP DEVELOPER AND THE CITY INSPECTOR REGARDING ANY SIGNIFICANT CHANGES TO BMP DEPLOYMENT. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREATE A HAZARDOUS CONDITION. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED SWPPP AND/OR EROSION CONTROL PLAN SHALL BE INCORPORATED HEREON. 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 10. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH 3/4 INCH MINIMUM AGGREGRATE. 11. SHOULD GERMINATION OF HYDROSEEDED SLOPES FAIL TO PROVIDE EFFECTIVE COVERAGE OF GRADED SLOPES (90% COVERAGE) PRIOR TO NOVEMBER 15, THE SLOPES SHALL BE STABILIZED BY PUNCH STRAW INSTALLED IN ACCORDANCE WITH SECTION 35.023 OF THE EROSION AND SEDIMENT CONTROL HANDBOOK OF THE DEPARTMENT OF CONSERVATION, STATE OF CALIFORNIA. I, JAIME A. CERROS, A REGISTERED GEOTECHNICAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION ON 8/17/2023. TWO COPIES OF THE SOIL REPORT COMPILED FROM THIS STUDY, WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. SIGNED: GEOTECHNICAL EXPLORATION INC. PHONE NUMBER: (858) 549-7222 G.E./P.E. NO.: R.C.E. 34422 G.E. 2007 DATE: LICENSE EXPIRATION DATE: SEPTEMBER 30, 2025 1. CARLSBAD MUNICIPAL CODE 2. CITY OF CARLSBAD ENGINEERING STANDARDS 3. THIS SET OF PLANS 4. RESOLUTION NO __________ DATED _________ AND NO __________ DATED _________ 5. THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK) 6. SOILS REPORT AND RECOMMENDATIONS BY GEOTECHNICAL EXPLORATION, INC: JOB. NO. 23-14403 DATED 1/29/2024 7. THE SAN DIEGO REGIONAL STANDARD DRAWINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS. 8. CALIFORNIA COASTAL COMMISSION DEVELOPMENT PERMIT CONDITIONS DATED _________ 9. ENVIRONMENTAL APPROVAL DOCUMENTS DATED________ 10. STORM WATER POLLUTION PREVENTION PLAN (TIER 2) PREPARED BY: ___________ , SEE SHEETS 5-6, DWG 549-9A. SW NO. ________ WDID NO. _________ 11. STORM WATER QUALITY MANAGEMENT PLAN PREPARED BY: ___________ DATED: _______________ 12. CALIFORNIA STORM WATER QUALITY ASSOCIATION BMP CONSTRUCTION HANDBOOK AND CALTRANS CONSTRUCTION SITE BMP MANUAL PLSA PLSA N/A N/A ABBREVIATION: SDRSD - SAN DIEGO REGIONAL STANDARD DRAWING CMWD - CARLSBAD MUNICIPAL WATER DISTRICT * NOTE: MODIFIED PER CITY OF CARLSBAD STANDARD TYPE DESCRIPTION OWNERSHIP AGREEMENT SHEET NO.FREQUENCY MAINTENANCE MAINTENANCE STORMWATER REQUIREMENTS THAT APPLY: STANDARD STORMWATER REQUIREMENTS PRIORITY PROJECT REQUIREMENTS YES NO EXEMPT FROM YES NO EXEMPT FROM TRASH CAPTURE?HYDROMODIFICATION? TRASH CAPTURE HOA 3 AS NEEDED 362 1666 X X W W S S G G 64 64 SD SD 496 LF LOT 5 INDUSTRIAL TRACT IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, AS PER MAP 1743, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAID SAN DIEGO COUNTY JANUARY 3, 1923. 215 SF 2 EA 4 EA JANUARY 2025 PARTIALLY COMPLETED PROJECTS SEEKING TO INDEFINITELY STOP WORK AND CLOSE THE GRADING PERMIT MUST IMPLEMENT APPROPRIATE ACCESS RESTRICTION AND EROSION AND SEDIMENT CONTROL MEASURES TO THE SATISFACTION OF THE CITY, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1) PERMANENTLY STABILIZE ALL SLOPES (>5%) - 70% COVER WITH WELL-ESTABLISHED, SUSTAINABLE, NON-WEED VEGETATION (SEE CITY LANDSCAPE MANUAL FOR GUIDELINES) IS CONSIDERED ADEQUATE. 2) PERMANENTLY STABILIZE FLAT AREAS (≤5%) - 70% COVER WITH WELL-ESTABLISHED, SUSTAINABLE, NON-WEED VEGETATION (SEE CITY LANDSCAPE MANUAL FOR GUIDELINES) OR 2 INCHES (MINIMUM) OF PERMEABLE COVER (E.G., GRAVEL) IS CONSIDERED ADEQUATE. 3) RESTRICT ACCESS TO SITE - COORDINATE WITH CITY STAFF TO DETERMINE APPROPRIATE FENCING TYPE. 4) SIGNAGE ALONG FRONTAGE ROAD(S) POSTING THAT DUMPING, LITTERING, AND TRESPASSING ARE PROHIBITED. 5) TRESPASS ENFORCEMENT AUTHORIZATION LETTER MUST BE SENT FROM THE OWNER TO THE CITY OF CARLSBAD POLICE DEPARTMENT. 6) NOTARIZE AND RECORD AGAINST THE PROPERTY AN AGREEMENT STATING THAT OWNER IS RESPONSIBLE FOR MAINTAINING FENCING AND SIGNAGE, ADHERING TO THE FIRE PREVENTION ORDINATION, KEEPING THE SITE FREE FROM LITTER ACCUMULATION AND VEGETATION GROWTH, AND REMOVING ANY ILLEGALLY DUMPED MATERIALS AT THE SITE UNTIL THE PROPERTY IS DEVELOPED IN THE FUTURE. IN SOUTHEAST CORNER OF DRAINAGE BOX INLET AT THE END OF CURB RETURN IN THE NORTHEAST CORNER OF GRAND AVENUE AND WASHINGTON STREET, 52 FEET WEST OF RAILROAD TRACKS AND 40 FEET NORTH OF THE CENTER OF GRAND AVENUE. DESCRIPTION: CLSB-130, 2.5" DISK LOCATION: RECORDED: ELEVATION: 40.91 DATUM: NGVD29 MAP 775 MAP 1743 CR 20872 CR 24398 CR 30120 CR 9487 ROS 9309 ROS 14504 ROS 03194 ROS 16439 BF = BOTTOM OF FOOTING ELEVATION EG = EXISTING GRADE FS = FINISHED SURFACE FG = FINISHED GRADE FL = FLOWLINE FF = FINISHED FLOOR GLIP = GARAGE LIP ELEVATION IE = INVERT ELEVATION LA = LANDSCAPE AREA TC = TOP OF CURB TG = TOP OF GRATE ELEVATION RIM = TOP OF RIM ELEVATION EXISTING GRADE FYSB = FRONT YARD SETBACK RYSB = REAR YARD SETBACK SYSB = SIDE YARD SETBACK (IN ADDITION TO THE REQUIREMENTS OF CHAPTER 15.16 OF THE CARLSBAD MUNICIPAL CODE.) 1. THIS PLAN SUPERSEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD REGARDING GRADING SHOWN ON THIS SET OF PLANS. 2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAIVE ANY PORTION OF THE CARLSBAD MUNICIPAL CODE, RESOLUTION OF CONDITIONAL APPROVAL, CITY STANDARDS OR OTHER ADDITIONAL DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT. THE ENGINEER IN RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE IS DISCOVERED. 3. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER-OF- WORK FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL. 4. A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT OF WAY. PRIOR TO PERMIT ISSUANCE, A CERTIFICATE OF INSURANCE AS WELL AS ADDITIONAL INSURED ENDORSEMENT MUST BE FILED NAMING THE CITY OF CARLSBAD AS AN ADDITIONAL INSURED ON THE PERMITTEE'S POLICY IN THE MINIMUM AMOUNT OF $1,000,000.00 FOR EACH OCCURRANCE OF LIABILITY. THE INSURANCE COMPANY WRITING THE POLICY MUST HAVE A RATING OF "A-" OR BETTER AND A SIZE CATEGORY OF CLASS VII OR BETTER AS ESTABLISHED BY "BESTS" KEY RATING GUIDE. 5. NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HAVE BEEN OBTAINED FROM THE CITY AND OTHER APPROPRIATE AGENCIES. 6. REVISION OF THESE PLANS MAY BE REQUIRED IF THE PROPOSED IMPROVEMENTS ARE NOT CONSTRUCTED PRIOR TO THE DEADLINE DATE OF THE IMPROVEMENT AGREEMENT. 7. APPROVAL OF THESE PLANS BY THE CITY ENGINEER DOES NOT AUTHORIZE ANY WORK OR GRADING TO BE PERFORMED UNTIL THE PROPERTY OWNER'S PERMISSION HAS BEEN OBTAINED AND A VALID GRADING PERMIT HAS BEEN ISSUED. 8. NO REVISIONS WILL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE CITY ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE APPROPRIATE SHEET OF THE PLANS AND THE TITLE SHEET. 9. ORIGINAL DRAWINGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING SIGNED BY THE CITY ENGINEER. 10. THE ORIGINAL DRAWING SHALL BE REVISED TO REFLECT AS-BUILT CONDITIONS BY THE ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. 11. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT ALL TIMES DURING CONSTRUCTION. 12. WHERE TRENCHES ARE WITHIN CITY EASEMENTS, A SOILS REPORT COMPRISED OF: (A) SUMMARY SHEET, (B) LABORATORY WORK SHEETS AND (C) COMPACTION CURVES, SHALL BE SUBMITTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. THE SOILS REPORT WILL BE SUBMITTED TO THE CITY ENGINEERING INSPECTOR WITHIN TWO WORKING DAYS OF THE COMPLETION OF FIELD TESTS. 13. A SOILS COMPACTION REPORT AND COMPLIANCE VERIFICATION REGARDING ADHERENCE TO RECOMMENDATIONS OUTLINED IN THE SOILS REPORT IS REQUIRED PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL CONTROLLED GRADING SHALL BE DONE UNDER THE DIRECTION OF A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. ALL FILL OR FUTURE FILL AREAS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF CARLSBAD STANDARD SPECIFICATIONS AND THE " EARTHWORK SPECIFICATIONS " ATTACHED TO THE PRELIMINARY SOILS INVESTIGATION. DAILY FIELD COMPACTION REPORTS WILL BE SUBMITTED TO THE PROJECT INSPECTOR. 14.A PRECONSTRUCTION MEETING SHALL BE HELD PRIOR TO THE BEGINNING OF WORK AND SHALL BE ATTENDED BY ALL REPRESENTATIVES RESPONSIBLE FOR CONSTRUCTION, INSPECTION, SUPERVISION, TESTING AND ALL OTHER ASPECTS OF THE WORK. THE CONTRACTOR WILL BE CONTACTED BY THE PROJECT INSPECTOR TO COORDINATE A DATE AND TIME FOR THE PRECONSTRUCTION MEETING. APPROVED DRAWINGS MUST BE AVAILABLE PRIOR TO SCHEDULING. THE GRADING PERMIT WILL BE PROVIDED BY THE PROJECT INSPECTOR AT THE MEETING. 15.ALL INSPECTION REQUESTS OTHER THAN FOR PRECONSTRUCTION MEETING WILL BE MADE BY CALLING THE ENGINEERING 24-HOUR INSPECTION REQUEST LINE AT (760) 438-3891. INSPECTION REQUEST MUST BE RECEIVED PRIOR TO 2:00 P.M. ON THE WORKING DAY BEFORE THE INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE. REQUESTS MADE AFTER 2:00 P.M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER. 16. THE OWNER AND/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 17. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL PLAN TO THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING SLOPING OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECTION FROM THE HAZARD OF CAVING GROUND DURING THE EXCAVATION OF SUCH TRENCH OR TRENCHES OR DURING THE PIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5') OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PLAN VARIES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS, TITLE 8 CALIFORNIA ADMINISTRATIVE CODE, THE PLAN SHALL BE PREPARED BY A REGISTERED ENGINEER AT THE CONTRACTORS EXPENSE. A COPY OF THE OSHA EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION. 18. NO BLASTING SHALL BE PERFORMED UNTIL A VALID BLASTING PERMIT HAS BEEN OBTAINED FROM THE CITY OF CARLSBAD. SUBMIT APPLICATION FOR BLASTING PERMIT WELL IN ADVANCE OF THE SCHEDULING OF BLASTING OPERATIONS. 19.IF ANY ARCHAEOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK AREA DURING CONSTRUCTION, OPERATIONS WILL CEASE IMMEDIATELY, AND THE PERMITTEE WILL NOTIFY THE CITY ENGINEER. OPERATIONS WILL NOT RESTART UNTIL THE PERMITTEE HAS RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO DO SO. 20. ALL OPERATIONS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR OPERATION OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED GRADING EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 7:00 A.M. AND 6:00 P.M. EACH DAY, MONDAY THRU FRIDAY AND NO EARTHMOVING OR GRADING OPERATIONS SHALL BE CONDUCTED ON WEEKENDS OR HOLIDAYS. (A LIST OF CITY HOLIDAYS IS AVAILABLE AT THE ENGINEERING DEPARTMENT COUNTER.) 21.ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY INSPECTOR FOR APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING OF WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTE OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 22. IMPORT MATERIAL SHALL BE OBTAINED FROM, AND WASTE MATERIAL SHALL BE DEPOSITED AT, A SITE APPROVED BY THE CITY ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTES OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 23. BRUSH SHALL BE REMOVED ONLY WITHIN THE AREA TO BE GRADED. NO TREES ARE TO BE REMOVED UNLESS SPECIFICALLY NOTED ON THE PLAN. 24. ALL AREAS SHALL BE GRADED TO DRAIN. GRADING RESULTING IN THE PONDING OF WATER IS NOT PERMITTED. ALL EARTHEN SWALES AND DITCHES SHALL HAVE A MINIMUM ONE PERCENT SLOPE. 25. THESE PLANS ARE SUBJECT TO A SIGNED AND APPROVED SWPPP AND/OR SET OF EROSION CONTROL PLANS. EROSION CONTROL SHALL BE AS SHOWN AND AS APPROVED BY THE CITY ENGINEER OR AS DIRECTED BY THE PROJECT INSPECTOR. 26. ALL SLOPES SHALL BE TRIMMED TO A FINISH GRADE TO PRODUCE A UNIFORM SURFACE AND CROSS SECTION. THE SITE SHALL BE LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS OR OTHER DEBRIS SHALL BE REMOVED AND DISPOSED OF AT A SITE APPROVED OF BY THE CITY ENGINEER. 27. ALL SLOPES SHALL BE IRRIGATED, STABILIZED, PLANTED AND/OR HYDROSEEDED WITHIN TEN (10) DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED GRADING PLANS. 28. LANDSCAPING SHALL BE ACCOMPLISHED ON ALL SLOPES AND PADS AS REQUIRED BY THE CITY OF CARLSBAD LANDSCAPE MANUAL, THE LANDSCAPING PLANS FOR THIS PROJECT, DRAWING NO. 538-7L , AND/OR AS DIRECTED BY THE CITY ENGINEER OR PLANNING DIRECTOR. 29. THE OWNER/APPLICANT SHALL INSURE THAT ALL CONTRACTORS SHALL COORDINATE THE WORK OF THESE GRADING PLANS WITH THAT SHOWN ON BOTH THE LANDSCAPE AND IRRIGATION PLANS AND THE IMPROVEMENT PLANS AS REQUIRED FOR THIS WORK IN ACCORDANCE WITH THE LANDSCAPE MANUAL TIME REQUIREMENTS. 30. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED AS A RESULT OF THE GRADING OPERATION, IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. 31. THE EXISTENCE AND LOCATION OF UTILITY STRUCTURES AND FACILITIES SHOWN ON THE CONSTRUCTION PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. ATTENTION IS CALLED TO THE POSSIBLE EXISTENCE OF OTHER UTILITY FACILITIES OR STRUCTURES NOT SHOWN OR IN A LOCATION DIFFERENT FROM THAT SHOWN ON THE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN ON THE PLANS AND ANY OTHER EXISTING FACILITIES OR STRUCTURES NOT SHOWN. 32. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES ( ABOVE GROUND AND UNDER GROUND ) WITHIN THE PROJECT SITE SUFFICIENTLY AHEAD OF GRADING TO PERMIT THE REVISION OF THE GRADING PLANS IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN CONFLICT WITH THE PROPOSED WORK. 33. THE CONTRACTOR SHALL NOTIFY AFFECTED UTILITY COMPANIES (SEE BELOW) AT LEAST 2 FULL WORKING DAYS PRIOR TO STARTING GRADING NEAR THEIR FACILITIES AND SHALL COORDINATE THE WORK WITH A COMPANY REPRESENTATIVE. UNDERGROUND SERVICE ALERT (800)422-4133 SDG&E (800)411-7343 AT&T (800)892-0123 TIME WARNER CABLE (760)438-7741 COX COMMUNICATIONS (619)262-1122 CITY OF CARLSBAD(STREETS & STORM DRAIN)(760)434-2980 CITY OF CARLSBAD(SEWER,WATER & RECLAIMED WATER) (760)438-2722 34. PERMIT COMPLIANCE REQUIREMENTS: A.FOR CONTROLLED GRADING - THE APPLICANT HIRES A CIVIL ENGINEER, SOILS ENGINEER, AND/OR GEOLOGIST TO GIVE TECHNICAL ADVICE, OBSERVE AND CONTROL THE WORK IN PROGRESS {15.16.120 A.8} CARLSBAD MUNICIPAL CODE. B.PRIOR TO FINAL APPROVAL OF A GRADING PERMIT - THE FOLLOWING REPORTS MUST BE SUBMITTED TO THE CITY ENGINEER VIA THE PROJECT INSPECTOR {15.16.120 A.10} CARLSBAD MUNICIPAL CODE: (1) FINAL REPORT BY SUPERVISING GRADING ENGINEER STATING ALL GRADING IS COMPLETE. ALL EROSION CONTROL, SLOPE PLANTING AND IRRIGATION ARE INSTALLED IN CONFORMANCE WITH CITY CODE AND THE APPROVED PLANS ( OBTAIN SAMPLE OF COMPLIANCE LETTER FROM CITY ENGINEERING DEPARTMENT). (2) AS-BUILT GRADING PLAN. (3) REPORT FROM THE SOILS ENGINEER, WHICH INCLUDES RECOMMENDED SOIL BEARING CAPACITIES, A STATEMENT AS TO THE EXPANSIVE QUALITY OF THE SOIL, AND SUMMARIES OF FIELD AND LABORATORY TESTS AND PLOTTED TEST POINTS THE REPORT SHALL ALSO INCLUDE A STATEMENT BY THE SOILS ENGINEER THAT THE GRADING WAS DONE IN ACCORDANCE WITH THE REQUIREMENTS AND RECOMMENDATIONS OUTLINED IN THE PRELIMINARY SOILS REPORT AND ANY SUPPLEMENTS THERETO. (4) REPORT WITH AS-BUILT GEOLOGIC PLAN, IF REQUIRED BY THE CITY. 35. UNLESS A GRADING PERMIT FOR THIS PROJECT IS ISSUED WITHIN ONE (1) YEAR AFTER THE CITY ENGINEER'S APPROVAL, THESE PLANS MAY BE REQUIRED TO BE RESUBMITTED FOR PLANCHECK. PLANCHECK FEES WILL BE REQUIRED FOR ANY SUCH RECHECK. 35. IN ACCORDANCE WITH THE CITY STORM WATER STANDARDS, ALL STORM DRAIN INLETS CONSTRUCTED BY THIS PLAN SHALL INCLUDE "STENCILS" BE ADDED TO PROHIBIT WASTEWATER DISCHARGE DOWNSTREAM. STENCILS SHALL BE ADDED TO THE SATISFACTION OF THE CITY ENGINEER. TOTAL LOT AREA = 22,768 SF DISTURBED ROW AREA = 628 SF TOTAL DISTURBED AREA = 23,396 SF (THIS AREA INCLUDES BUT IS NOT LIMITED TO OFF-SITE WORK INCLUDING PUBLIC IMPROVEMENTS AND TEMPORARY DISTURBANCE SUCH AS VEHICLE AND EQUIPMENT STAGING AREAS, CONSTRUCTION TRENCHES, BACKFILL CUTS AND SLOPE KEYWAYS) *TOTAL NEW / REPLACED IMPERVIOUS AREA = 15,809 SF I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. BY: DATE: BRYAN A. KNAPP, R.C.E. R.C.E. NO.: 86542 REGISTRATION EXPIRATION DATE: 03-31-2027 FIRM: PASCO, LARET, SUITER, AND ASSOCIATES, INC. ADDRESS: 1911 SAN DIEGO AVE, SUITE 100 CITY, STATE: SAN DIEGO, CA 92110 TELEPHONE: (858) 259-8212 NAME: JOHN NORUM FOR: TYLER STREET DEV LLC ADDRESS: 2888 LOKER AVENUE EAST, SUITE 220 CARLSBAD, CA 92008 PHONE NO.:(949) 678-4927 TITLE SHEET 1 REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. TYLER STREET HOMES CT 2024-0001 549-9A GR 2024-0023 PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4070 9 TC-32 HOA 3 AS NEEDED REM TRITON TDAM12(5)-PERF-FTC BIOFILTRATION BASIN N/A N/A 2025-027 1/28/2025 24 EA PROPERTY BOUNDARY CENTERLINE OF ROAD ADJACENT PROPERTY LINE PUBLIC RIGHT-OF-WAY SETBACK LINE EXISTING CONTOUR LINE PROPOSED CONTOUR LINE PROPOSED FLOWLINE PROPOSED DIRECTION OF FLOW PROPOSED PCC FLUSH CURB (SIZE PER PLAN) PROPOSED MASONRY RETAINING WALL PROPOSED DEEPENED FOOTING PER SEPARATE ARCHITECTURAL PLAN PROPOSED PCC PAVEMENT* PROPOSED PERVIOUS PAVERS: COLOR AND FINISH PER SEPARATE PLAN EXISTING FENCE EXISTING WATER MAIN (SIZE PER PLAN) EXISTING SEWER MAIN (SIZE PER PLAN) EXISTING GAS MAIN (SIZE PER PLAN) PROPOSED 4" PVC PRIVATE STORM DRAIN PIPING; UNLESS NOTED OTHERWISE ON PLAN PROPOSED 6" AREA DRAIN ( BY NDS OR APPROVED EQUAL) PROPOSED 12"X12" BROOKS BOX W/ REM TRITON TDAM12(5)-PERF-FTC (TRASH CAPTURE BMP) PROPOSED 24"X24" BROOKS BOX W/ REM TRITON TDAM12(5)-PERF-FTC (TRASH CAPTURE BMP) PCC RIBBON GUTTER PROPOSED RAISED PLANTER BMP PROPOSED HEADWALL 7 EA YES YES 7527 11/6/2024 1 EA 4/21/2025 4/23/2025 GEI JOB NO. 23-14403 4/23/2025 1 TITLE SHEET / NOTES 2 DEMOLITION PLAN 3 GRADING PLAN 4 SECTIONS AND DETAILS 5 DETAILS 6 DETAILS 7 TIER 2 SWPPP COVER SHEET 8 TIER 2 SWPPP 9 SINGLE SHEET BMP SITE PLAN NF NF GRADING NOTES SHEET NOTES ~ WORK TO BE DONE ~ -', ~ / -~\ ' ' /~ LEGEND DESCRIPTION STD. SYMBOL QUANTITY -- LEGAL DESCRIPTION VICINITY MAP - OWNER'S CERTIFICATE ---------- BENCHMARK .. BASIS OF BEARINGS ~;1/&~ I/ // // /I EROSION CONTROL NOTES I · . . SOURCE OF TOPOGRAPHY ' F<ZS(<'.:<2'.<I PROJECT ADDRESS ABBREVIATION LEGEND PROJECT LOCATION REFERENCE DRAWINGS a EARTHWORK QUANTITIES [ii □ OWNERLDEVELOPER INFORMATION INDEX OF SHEETS •-. • : ~ • • b, .• . : ~ . • t,,.. • • : ~ • . . . . DISTURBED AND IMPERVIOUS AREA ' :·~·~· +~·:~ •• + ••• + •• + + + + ffi-- ABANDONMENT NOTES SOILS ENGINEER'S CERTIFICATE DECLARATION OF RESPONSIBLE CHARGE (SHEETS 1-9) ~~ .. 7 ~ioHSSio,v. PL S A ~ ~<., ~-C£,? '-1t <". 7 :::? ~ 1'o t, c.-, ~ ""' :;..--:: df?;-?7 ~ GE 2007 ~ 11--~ .., "" = = ... ~1;s\lf ESS / 0,1: EXP. 9/30/1,'i * * ~ ~ ~KDRtw Ir, '-'It ~ tfCH\\I"~\~ PLSAEN GINEERING.COM g~ %~ or c~1.1~1:J c,,:, Qj --0 ---z. ~ No. 86542 ~ I SHEET II CITY OF CARLSBAD 11 SHEETS I °" Exp. 03/31 /27 =<> * * J'~?. C/VI \. rS;*~ GRADING PLANS FOR: - ~ ~ ~ t OF C/\\.1~ - APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63912 EXPIRES 9/30126 DAlE DWN BY: I PROJECT NO. I DRAWING NO. DAlE INITIAL DAlE INITIAL DAlE INITIAL CHKD BY: ENGINEER OF WORK REVISION DESCRIPTION OlHER APPROVAL CITY APPROVAL RVWD BY: Docusign Envelope ID: D48B54F8-556D-45B8-ABE2-69EB8EFFFC77 5/14/2025 XXXXX 45 45 4 5 45 45 45 45 1 S T O R Y R E S I D E N C E DE T A C H E D GA R A G E 1 S T O R Y RE S I D E N C E (C O N N E C T E D ) OV E R H A N G OV E R H A N G 1 S T O R Y RE S I D E N C E (C O N N E C T E D ) OVE R H A N G SH E D OV E R H A N G AU T O C A R E SH O P ST O R A G E BU I L D I N G SHIPPING CONTAINER X X X X X X X X X X X X X X X X X X X X X X XXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X S S S S S S S S S S S S S S S S S S S S S S S S G G G G G G G G G G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE W W OE OE OE OE OE OE OE OE OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOE OE OE OE OE OE OE OE OE OE OE OE OE OE N3 4 ° 0 0 ' 4 8 " W 1 3 9 . 8 7 ' N56°00'45"E 162.86' N3 4 ° 0 0 ' 4 8 " W 1 3 9 . 9 0 ' S56°00'01"W 162.86' LOT 6 MAP NO. 1743 APN: 204-070-28-00 LOT 4 MAP NO. 1743 APN: 204-010-08-00 FUTURE DEVELOPMENT APN: 204-010-10-00 SUBJECT PROPERTY GROSS AREA = 22,768 SF (0.52 AC) APN: 204-010-09-00 20.0'20.0' 40.0' 5 5 5 5 5 5 5 3 3 2 2 1 8 8 8 6 6 6 6 6 6 3 3 3 8 6 4 7 4 5 TY L E R S T R E E T PINE AVENUE 10 11 8 ~1 . 0 ' ~2 . 0 ' ~3 . 0 ' 8 8 8 ~2 . 9 ' 44 4 3 43 44 44 43 43 44 44 46 46 9 9 9 ~4 . 9 ' ~4 . 8 ' 9 ~1 . 5 ' 10 GRAPHIC SCALE: 1" = 10' 0 10'20'30' J:\ACTIVE JOBS\4070 NORUM-CARLSBAD-Tyler Street\CIVIL\DRAWING\GRADING PLANS REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. TYLER STREET HOMES CT 2024-0001 549-9A GR 2024-0023 PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4070 9PLAN VIEW - DEMO PLAN SCALE: 1" = 10' HORIZONTAL DEMO NOTES 1 EXISTING SURVEY MOMUMENT TO REMAIN; SEE NOTE 4 THIS SHEET EXISTING WALL TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING DIRT EXISTING STRUCTURE TO BE REMOVED EXISTING PCC HARDSCAPE TO BE REMOVED EXISTING ASPHALT DRIVE TO BE REMOVED EXISTING OFFSITE STRUCTURE OVERHANG EXISTING OFFSITE STRUCTURE EXISTING OVERHEAD LINE TO BE REMOVED EXISTING OVERHEAD LINE TO REMAIN 2 3 4 5 6 1. CONTRACTOR TO KILL EXISTING GAS SERVICES PRIOR TO DEMOLITION OF ANY STRUCTURES 2. CLEAR AND GRUB EXISTING ONSITE VEGETATION; DISPOSE OF ANY EXISTING ONSITE DEBRIS. 3. EXISTING SURVEY MONUMENTS SHALL BE PROTECTED IN PLACE. MONUMENT(S) DISTURBED OR DESTROYED SHALL BE REPLACED BY A LICENSED LAND SURVEYOR WHO SHALL FILE A CORNER RECORD WITH THE COUNTY. ADDITIONAL NOTES LEGEND PROPERTY BOUNDARY CENTERLINE OF ROAD ADJACENT PROPERTY LINE PUBLIC RIGHT-OF-WAY EXISTING CONTOUR LINE EXISTING FENCE EXISTING WATER MAIN EXISTING SEWER MAIN EXISTING GAS MAIN EXISTING WALL EXISTING BUILDING OVERHANG EXISTING BUILDING X X W W S S G G 7 8 DEMOLITION PLAN 2 9 10 11 NF NF I I I I I I I ' I ., • -' -, I . I . .... ' I '· ' -, i ' -1· /. .... , \ ... -, ' -, / -, I -, I ' ' I I I I I I I --,- 1 I ' / I· / -, I [ __ _ /1' / r I I I ,._ I I ' • '-1 i ' -' T' I -, .1 I I I I ' -I I I I . I ' I I \ ' \ ' \ . \ ' I ' I I / ~-----7 I... I I /.. I I I I I ,·.- ' . ...... ...... /' ' I I ,· ---f. ...... ,· . \' I I I, ' .• ' ,-.... --- '\ '\ ' ' \ ' \ ,, ,· . \ '·.· \ ' .. I ' Jj ---- -, I I ' ' • \ .+J I \" • I \ I ,. .,,. .,,. I .,,. .,,. .,,. I , I-,--',-----~, ' ' .,,. .,,. •,•--, -, .,,. I -, ' I I • ' ' ' -,· ' ,· . I 1'· ... ·, . ,~'' .,,. .,,. .,,. .,,. .,,. .,,. .,,. .,,. .,,. ' o--1 I I I \ I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I il l I I I I I I I I I I I I I I 7 ~ I I I I I I I I I I I I H--\ \ \ \ \ \ \ I \ I ,, I I I I I I I I I I I I I I I I I I I C = \-----, aas I I 0 0 0 0 0 0 0 0 0 0 0 ---------- ---64 ---- ■■■■■■■■■■■ I I t----+--+-----------1-------i----t-------r------i ~ 11 CITY OF CARLSBAD I LJ GRADING PLANS FOR: APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63912 EXPIRES 9 30 26 DAlE DA 1E INITIAL ENGINEER OF WORK REVISION DESCRIPTION DA 1E INITIAL DAlE INITIAL DlHER APPROVAL CITY APf'ftOVAL DWN BY: __ _ CHKD BY: __ _ RVWD BY: PROJECT NO. DRAWING NO. Docusign Envelope ID: D48B54F8-556D-45B8-ABE2-69EB8EFFFC77 5/14/2025 45 45 4 5 45 SH E D AU T O C A R E SH O P ST O R A G E BU I L D I N G SHIPPING CONTAINER X X XXXX X X X X X X X X X X X S S S S S S S S S S S S S S S S S S S S S S S G G G G G G G G G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W W W IRR IRR IRR IRR W W W W S S S F F F F SD SD W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W C JT JT JT JT JT JT JT JT JT SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD WM WM JT JT JT JT J T JTJTJTJTJTJTJTJT JT JT OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE W WW W SD SD SD SD SD SD JT X X X X XXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXX X X X XX XX XXX XXX X X X XX XX X N3 4 ° 0 0 ' 4 8 " W 13 9 . 8 7 ' N56°00'45"E 162.86' N3 4 ° 0 0 ' 4 8 " W 1 3 9 . 9 0 ' N56°00'01"E 162.86' 1 46 . 7 T W 46 . 5 T W @ F G (4 5 . 8 B W @ E G ) 44 . 7 T F H = 2 . 0 F T 46 . 8 T W 46 . 6 T W @ F G (4 5 . 5 B W @ E G ) 44 . 8 T F H = 2 . 0 F T 46 . 6 F G PROPERTY LINE1 46 . 5 T W 46 . 3 T W @ F G (4 3 . 9 B W @ E G ) 43 . 2 T F H = 3 . 3 F T 46 . 3 F G 46 . 2 T W 46 . 0 T W @ F G (4 3 . 8 B W @ E G ) 42 . 9 T F H = 3 . 3 F T LOT 6 MAP NO. 1743 APN: 204-070-28-00 LOT 4 MAP NO. 1743 APN: 204-010-08-00 FUTURE DEVELOPMENT APN: 204-010-10-00 8 ±5 ' 46 . 0 T W 45 . 8 T W @ F G (4 3 . 4 B W @ E G ) 42 . 7 T F H = 3 . 3 F T 45 . 8 F G 45 . 8 T W 45 . 6 T W @ F G (4 3 . 3 B W @ E G ) 42 . 5 T F H= 3 . 3 F T 45 . 7 F G ±5 ' 45 . 1 T W 44 . 9 T W @ F G (4 3 . 2 B W @ E G ) 42 . 4 T F H = 2 . 7 F T 43 . 1 T W 42 . 9 T W @ F G (4 2 . 9 B W @ E G ) 42 . 4 T F H = 0 . 7 F T PUBLIC ROW 46 . 5 T W 46 . 3 T W @ F G (4 5 . 3 B W @ E G ) 44 . 5 T F H = 2 . 0 F T 46 . 7 T W 46 . 5 T W @ F G (4 5 . 2 B W @ E G ) 44 . 7 T F H = 2 . 0 F T PROPERTY LINE1 46 . 2 F G 46 . 4 T W 46 . 2 T W @ F G (4 4 . 1 B W @ E G ) 43 . 1 T F H = 3 . 3 F T 46 . 2 T W 46 . 0 T W @ F G (4 3 . 8 B W @ E G ) 42 . 9 T F H = 3 . 3 F T 8 45 . 8 F G 46 . 0 T W 45 . 8 T W @ F G (4 3 . 9 B W @ E G ) 43 . 3 T F H = 2 . 7 F T 45 . 7 F G 45 . 8 T W 45 . 6 T W @ F G (4 2 . 9 B W @ E G ) 41 . 8 T F H = 4 . 0 F T 45 . 1 T W 44 . 9 T W @ F G (4 2 . 8 B W @ E G ) 41 . 8 T F H = 3 . 3 F T 43 . 0 T W 42 . 8 T W @ F G (4 2 . 8 B W @ E G ) 42 . 3 H = 0 . 7 F T 45.7 FG/HP 6" TEE AT 10' O.C. TO DISCHARGE THROUGH HEAD WALL, TYP. 43.1 IE Q100 (MIT) = 0.03 CFS V100 (MIT) = 1.37 FT/S (43.0 EG) 4 (43.1 EG) 43.1 IE Q100 (MIT) = 0.03 CFS V100 (MIT) = 1.37 FT/S (43.2 EG) 43.2 IE Q100 (MIT) = 0.03 CFS V100 (MIT) = 1.37 FT/S 4 PROPERTY LINE PER LOT LINE ADJUSTMENT (COC DOC# 2024-0147448 RECORDED JUNE 12, 2024) PROP. 24-FT WIDE PRIVATE UTILITY AND ACCESS EASEMENT (43.2 EG) PROP. TRANSFORMER 6" TEE AT 10' O.C. TO DISCHARGE THROUGH HEAD WALL, TYP. (43.3 EG) 43.3 IE Q100 (MIT) = 0.02 CFS V100 (MIT) = 1.25 FT/S 4 (43.1 EG) 43.2 IE Q100 (MIT) = 0.02 CFS V100 (MIT) = 1.25 FT/S 4 (43.0 EG) 43.1 IE Q100 (MIT) = 0.02 CFS V100 (MIT) = 1.25 FT/S 4 43.1 IE Q100 (MIT) = 0.02 CFS V100 (MIT) = 1.25 FT/S (43.0 EG) 4 45 . 7 F G / H P 45.4 TG 43.4 IE 5 45.7 FG 45.7 FG/HP 48.7 TG 46.0 IE 6 6.0' 10.11' BMP #9 A = 48 SF 48.2 FG UNIT 12 FF = 46.4 PAD = 45.7 1-4" STEP 46.0 FG 45.8 FG 45.8 FG 45.9 FG 48.9 TG 46.2 IE6 49.4 TG 46.7 IE 6 PROP. MAILBOX 5.0' PUBLIC R/W DEDICATION 15.0'6.0' 45.4 TG 43.4 IE 5 45.8 FG 45.8 FG 45.9 FG 1-4" STEP 46.0 FG 45.7 FG 45.7 FG\HP 48.7 TG 46.0 IE 6 BMP #1 A = 48 SF 48.2 FG UNIT 6 FF = 46.4 PAD = 45.7 45.7 FG/HP 45.7 FG 45.7 FG 45.7 GLIP 6.0' 45.6 FG 14 UNIT 5 FF = 46.4 PAD = 45.7 1-4" STEP 46.0 FG BMP #2 A = 32 SF 48.2 FG 1-4" STEP 46.0 FG BMP #3 A = 22 SF 48.4 FG BMP #6 A = 30 SF 48.4 FG BMP #7 A = 32 SF 48.9 FG 1-6" STEP 46.7 FG 48.9 TG 46.2 IE 48.9 TG 46.2 IE 46.6 FG 49.4 TG 46.7 IE46.3 FG 46.4 FG BMP #8 A = 22 SF 48.9 FG 1-4" STEP 46.7 FG 46.6 FG 1-4" STEP 46.7 FG 49.4 TG 46.7 IE 6 46.6 FG 46 . 5 F G 5.0' STBK PROP. MAILBOX 46.7 FG 5.0' STBK PROP. BIKE RACK 46.6 FG 1-4" STEP 46.7 FG BMP #16 A = 22 SF 48.9 FG 1-4" STEP 46.7 FGBMP #15 A = 32 SF 48.9 FG 49.4 TG 46.7 IE6 46.5 FG46.4 FG 48.9 TG 46.2 IE 6 1-4" STEP 46.7 FG BMP #14 A = 30 SF 48.4 FG UNIT 9 FF = 47.1 PAD = 46.4 BMP #13 A = 22 SF 48.4 FG UNIT 8 FF = 47.1 PAD = 46.4 BMP #11 A = 22 SF 48.4 FG 1-4" STEP 46.0 FG BMP #10 A = 32 SF 48.2 FG 1-4" STEP 46.0 FG UNIT 11 FF = 46.4 PAD = 45.7 UNIT 10 FF = 46.4 PAD = 45.7 46.2 TG 44.9 IE3 44.9 IE 48.7 TG 46.0 IE6 12.2' 46.3 FG46.2 FG 45 . 1 F L 45.6 FG 45.7 FG 45.7 FG 45.7 GLIP 45.7 GLIP 45.7 GLIP 45.7 FG 46.0 FG BMP #12 A = 22 SF 48.2 FG 45.0 IE 48.9 TG 46.2 IE 6 46.1 FG 46.4 FG 46.4 GLIP 46.4 GLIP 46.4 GLIP 46.3 FG SIGHT TRIANGLE UNIT 7 FF = 47.1 PAD = 46.4 46.5 FG 45.7 GLIP UNIT 4 FF = 46.4 PAD = 45.7 45 . 3 F L 45 . 4 F L 20 . 0 ' 24 . 0 ' 3. 0 ' 3. 0 ' 6. 0 ' 5. 0 ' 2' 2' 3. 0 ' 45 . 5 F L 45.7 GLIP 46.0 FG 48.7 TG 46.0 IE6 46.2 TG 44.9 IE3 14.2' 46 . 2 F G 46 . 3 F G BMP #4 A = 22 SF 48.2 FG BMP #5 A = 22 SF 48.4 FG UNIT 3 FF = 47.1 PAD = 46.4 48.9 TG 46.2 IE 6 46.1 FG 46.4 FG GLIP 46.4 UNIT 2 FF = 47.1 PAD = 46.4 UNIT 1 FF = 47.1 PAD = 46.4 46.4 FG SIGHT TRIANGLE 46.4 FG 46 . 6 F G 45 . 8 F L 7 8 46 . 1 F L 24 . 0 ' 20 . 0 ' 9 20 . 0 ' 46 . 5 F L / H P 46 . 4 F L 46 . 0 F L GLIP 46.4GLIP 46.4 0.7%1. 0 % 1. 0 % 5. 0 % 5. 0 % 1. 0 % 1. 0 % 2.0%0.7%3. 6 % 3. 6 % 2. 2 % 2. 2 % 3. 8 % 3. 8 % 2. 4 % 2. 4 % 1.0%0.5% 4.8% 0.9% 2:1 0.5%1.2% 2:1 2. 0 % 2. 0 % 1. 0 % 2. 0 % 1. 0 % 4.9% 1.1% 1. 0 % 3. 9 % 2.5%0.7%0.7% 5. 0 % 0.7%0.7% 1. 0 % 4. 4 % 0.5% 3. 0 % 1.0% 1. 8 % 2. 0 % 2. 0 % 2. 0 % 3. 0 % 1. 0 % 2. 0 % 2. 0 % 2. 0 % 2. 0 % 3. 7 % 1.2%0.5% 1. 8 % 2. 0 % 3. 0 % 1.0% 1.0% 1. 0 % 1. 0 % 1. 5 % 1. 5 % 1. 5 % 1. 5 % 1. 5 % 1. 5 % 1. 5 % 1. 5 % 1. 5 % 1. 5 % 1. 5 % 1. 5 % 2.0%8.0% 2.0% 2.0% 3:1 2.0% 4. 2 % 4. 2 % 0.7%5. 0 % MAX 46 . 6 F G 46 . 2 F L TY L E R S T R E E T (S E E D W G 5 4 9 - 9 F O R P U B L I C IM P R O V E M E N T S I N R O W ) MAX MAX 10.11'6 6 10.0' STBK 9 10 10 10 10 10 10 10 10 10 10 46.6 FG 46.5 FG 46.4 FG 46.4 FG 45 . 9 T W 45 . 7 T W @ F G (4 3 . 3 B W @ E G ) 42 . 6 T F H= 3 . 3 F T 44.4 IE 45.1 IE 44.9 IE 6 44.9 IE 45.0 IE 44.5 IE 44.6 IE 46.1 FG 46.2 FG 44.2 IE 48.7 TG 46.0 IE6 44.6 IE 46.3 FG46.2 FG 10 45.1 IE 44.9 IE 46.2 FG 46.1 FG 44.7 IE44.6 IE 46.3 FG46.2 FG 44.5 IE 45.7 FG 44.2 IE 48.7 TG 46.0 IE6 44.4 IE 11 11 1111 1111 11 11 11 11 11 11 11 11 PINE AVENUE 9 9 9 45.1 TG 43.6 IE 16 10 PROP. PL EX. PL 8.0% 7.0' 8.0% 8" STEP 46.4 FS46.4 FS 8.0% 8" STEP 46.4 FS 46.4 FS 0. 5 % 0. 5 % 9 9 43.3 IE 10 12 12 12 12 12 12 43.2 IE TOP OF SLOPE BOTTOM OF SLOPE 4" STEP 46.1 FS 4" STEP 46.1 FS 4" STEP 46.1 FS 4" STEP 46.8 FS 4" STEP 46.8 FS 4" STEP 46.8 FS 4" STEP 46.1 FS 4" STEP 46.1 FS 4" STEP 46.1 FS 4" STEP 46.8 FS 4" STEP 46.8 FS 4" STEP 46.8 FS45.7 FG/HP 13 13 13 13 13 13 13 13 46.4 FG/GB 46.4 FG/GB 41.9 BF 2 41.9 BF 2 43.6 BF2 43.6 BF2 43.4 IE 43.4 IE 4544 4544 45.7 FG/HP 45.7 FG/HP AA B B EE 44.5 BF 2 44.2 BF 2 44.2 BF2 43.8 BF2 44.5 BF2 43.8 BF2 46.2 TG 44.6 IE3 46.2 TG 44.6 IE3 F G H H G FD D C C 9 9 14 (4 4 . 2 F G ) (4 4 . 8 F G ) (4 3 . 4 F G ) (4 3 . 1 F G ) (4 3 . 8 F G ) (4 3 . 8 F G ) (4 2 . 8 F G ) (4 4 . 8 F G ) 15 15 43.3 IE 43.3 IE 43.3 IE 43.2 IE 43.2 IE 0.5% 0.5% 6" PVC SD PIPE @ 1.5% MIN 6" P V C S D P I P E @ 1 . 0 % M I N 10 6" P V C S D P I P E @ 1 . 0 % M I N 10 10 6" PVC SD PIPE @ 1.0% MIN10 6" P V C S D P I P E @ 1 . 0 % M I N 10 6" P V C S D P I P E @ 1 . 0 % M I N 10 6" PVC SD PIPE @ 1.0% MIN10 10 10 11 45 . 4 T G 43 . 5 I E 3 45 . 7 T G 43 . 9 I E 3 45 . 7 T G 43 . 9 I E 3 45 . 4 T G 43 . 5 I E 3 43 . 5 I E 17 43 . 5 I E 17 GRAPHIC SCALE: 1" = 10' 0 10'20'30' J:\ACTIVE JOBS\4070 NORUM-CARLSBAD-Tyler Street\CIVIL\DRAWING\GRADING PLANS REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. TYLER STREET HOMES CT 2024-0001 549-9A GR 2024-0023 PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4070 9PLAN VIEW - GRADING PLAN SCALE: 1" = 10' HORIZONTAL GENERAL NOTES 1. ALL UTILITIES SHOWN HEREON PER BEST AVAILABLE RECORD INFORMATION. 2. ALL EXISTING ONSITE STRUCTURES TO BE DEMOLISHED UNLESS OTHERWISE NOTED. 3. ALL EXISTING ONSITE TREES TO BE REMOVED UNLESS OTHERWISE NOTED. 4. ALL ONSITE WATER, SEWER, AND STORM DRAIN FACILITIES TO BE PRIVATELY MAINTAINED. 5. HARDSCAPE SHALL DRAIN AWAY FROM PROPOSED STRUCTURES AT A MINIMUM OF 2.0% FOR 10 FEET, AND LANDSCAPE FOR A MINIMUM OF 5.0% IN ACCORDANCE WITH THE 2016 CALIFORNIA BUILDING CODE SECTION 1804.4. ANY DEVIATION SHALL REQUIRE RECOMMENDATION FROM PROJECT GEOTECHNICAL ENGINEER. 6. EXISTING SEWER LATERALS AND CLEANOUTS COULD NOT BE LOCATED. ABANDON EXISTING SEWER LATERALS PER CITY OF CARLSBAD STANDARD SPECIFICATION 15000-3.11. CONTRACTOR TO LOCATE DURING CONSTRUCTION. 7. FOR PRIVATE ONSITE WATER, RECYCLED WATER , FIRE, AND SEWER SEE SEPARATE PRIVATE UTILITY PLAN AND PRIVATE FIRE UNDERGROUND PLAN UNDER SEPARATE PERMIT SUBMITTAL. CONSTRUCTION NOTES 1 2 3 4 5 6 7 8 9 10 EASEMENT / DEDICATION NOTES PROPOSED 5.0' WIDE PUBLIC UTILITY EASEMENT AND PUBLIC STREET EASEMENT TO THE CITY OF CARLSBAD 1 EXISTING EASEMENTS NOTES ITEMS 1 THROUGH 3 ARE NON MAPPING ITEMS AND HAVE BEEN OMITTED HEREON. PROPOSED MASONRY RETAINING WALL PER SDRSD C-03 DEEPENED FOOTING; DEPTH PER PLANS PROPOSED 6" AREA DRAIN BY NDS OR APPROVED EQUAL PROPOSED RIP RAP ENERGY DISSIPATER PER SDRSD D-40; ROCK CLASS = No.2 BACKING T = 1.1 FT PROPOSED 12" X 12" BROOKS BOX OR APPROVED EQUAL. INSTALL REM TRITON TDAM12(5)-PERF-FTC; SEE DETAIL SHEET 5 (TRASH CAPTURE BMP) PROPOSED 4" DRAIN INLET BY NDS OR APPROVED EQUAL FOR EMERGENCY OVERFLOW PROPOSED PCC RIBBON GUTTER SEE DETAIL SHEET 4 PROPOSED PERVIOUS PAVERS SEE DETAIL SHEET 4 PROPOSED 6" WIDE 520-C-2500 PCC FLUSH CURB WITH DEEPENED EDGE 1.0' BELOW BOTTOM OF PAVER STORAGE LAYER INSTALL 4" PRIVATE PVC STORM DRAIN PIPE @ 1% MIN; UNLESS NOTED OTHERWISE ON PLAN PROPOSED VERTICAL CONNECTION TO PRE-FABRICATED RAISED PLANTER BOX, SEE DETAIL SHEET 5-6 PROPOSED MODIFIED CUTOFF WALL PER DETAIL SHEET 4 PROPOSED BUILDING OVERHANG PROPOSED FREE STANDING 6" CURB PER SDRSD G-01 BERM @ TOP OF SLOPE PER DETAIL ON SHEET 4 PROPOSED 24" X 24" BROOKS BOX OR APPROVED EQUAL. INSTALL REM TRITON TDAM12(5)-PERF-FTC; SEE DETAIL SHEET 5 (TRASH CAPTURE BMP) PROPOSED RETAINING WALL 3" PVC DRAINAGE PIPE PER DETAIL SHEET 4 *AS MODIFIED PER CITY OF CARLSBAD STANDARDS 11 GRADING PLAN 3 12 13 14 15 16 17 NF NF ' ,1 ~--~=--_JI u_ ---~ --.------- \ \ \ \ I \ / - I -, - / I " --J l --( / / l I; 'I I I I \ --~ 7· -,-' ,.-.d'r--. -r t / ,, / ., / ' • '--1 ; ( I I ' ' \ J I t t -' / ' I I I ' - -J I , - I I I I -J t t I : ~:: :,• ~~........_ -.. • J~ ---------;;;;:_ r ~ ' r' I I I ' , I p - ~ I I I I I I I I I I I I Jj I I ' I I I J_ I 7 / /~ I I ~ C='=-= I I I I I I I I I I / I I I t-+----H---:-- -\ I \ I \ I \ I \ I \ I I il l_ ~~~h. ~ \ I \\I ~ E ~ t L I n----+lf-+--- • I . I " I -I r .. i I I I I I I . l I . ·1 i\ I I /-½HI I fH---I ----+-- l:.iil-D----+ztl I I I --+- • I ,I-+ " I "' I • Li -· I . I I I I I I I I I I I I I I I I I I I I I I I 0 0 0 0 0 0 0 0 0 4 1 i-1L 0 0 0 0 0 0 0 I I " " .,. I II I\--¼) I i -+ )! I <t \ I ) I r;:::::::::::,-I ' I I "'. ~} l~I _j I I _ <1 • /~,, -I I I l A 0 □ -----c: t-----+--+------------------,t-----+---+-----+-----t ~ 11 CITY OF CARLSBAD I LJ 1----+----+--------------+----+-------t,-----+------t GRADING PLANS FOR: APPROVED: JASON S. GELDERT t----+----+--------------+----+-------tf----+------t ::;;EN:;:;:;Gl;:;::N:;;;EE;:;Rl:::::::NG::::::M:::AN::::A::GER=:';::::::::R:::CE::::::6::::3::::91::::2::::::::EXP:::::::::::IRES:::::::9=:::;'30~26:::::::=D:::::A::::lE:::::: 1------cD~AlE~l-,1=N111=•--+,--------------+----+-------tf----+------I DWN BY: --PROJECT NO. I DRAWING NO. ~ 1--DA_lE~~IN_lll_AL--t-_DA_lE~~•N_lll_AL---1 CHKD BY: __ ENGINEER OF WORK REVISION DESCRIPTION DlHER APPROVAL CITY APf'ftOVAL RVWD BY: Docusign Envelope ID: D48B54F8-556D-45B8-ABE2-69EB8EFFFC77 5/14/2025 X FENCE PER SEPARATE LANDSCAPE PLANS; COMBINED WALL AND FENCE HEIGHT NOT TO EXCEED 6' FROM LOWEST ADJACENT GRADE TW PER PLAN = TOP OF WALL AT FINISH SURFACE 0.5' MIN COVER OVER FOOTING PER SDRSD TYP. BW PER PLAN = BOTTOM OF WALL AT FINSIHED GRADE *H = EXPOSED WALL HEIGHT = TW - BW PERFORATED PVC SCHEDULE 40 OR SDR 3" DIAMETER PIPE WITH 0.5% SLOPE, WITH 1.5 CU-FT OF GRAVEL 1" DIAMETER MAX WRAPPED IN GEOFABRIC MIRAFI 140N PL 0.3'WATERPROOFING TO TOP OF WALL BY OTHERS MIRADRAIN 6000 PROPOSED MASONRY RETAINING WALL PER SDRSD C-03 1.0' 1. 0 ' PERVIOUS PAVERS PER DETAIL THIS SHEET 1%-5%1%-5%FL PROPOSED 3' WIDE 5" THICK PCC RIBBON GUTTER 1.5'1.5' 3.0' 0.05'FL + 0.05' GLIP (1% X-SLOPE) = FL + 0.2 GLIP (5% X-SLOPE) = FL + 0.6 Q100 DEPTH = 0.1' FREEBOARD = 0.1' E B C A TY L E R S T R E E T AE B C F F D D GG HH 4" CLEANOUT / INSPECTION PORT WITH ATRIUM GRATE RIM = FG + 6" 3" HARDWOOD MULCHTW ELEV. = BMP FG + 12" PRE-FABRICATED RAISED PLANTER BOX; SEE DETAILS SHEET 5 FS ELEV. PER PLAN PLANTER WATERPROOFING IMPERVIOUS LINER LDPE 30-MIL 4" DIAMETER PERFORATED UNDERDRAIN PIPE 4" PVC OUTLET PIPE (TYP.) 4" DRAIN INLET BY NDS OR APPROVED EQUAL WITH ATRIUM GRATE FOR EMERGENCY OVERFLOW DEEP ROOTED, DENSE, DROUGHT TOLERANT PLANTING SUITABLE FOR WELL-DRAINED SOIL ROOF DOWNSPOUT PIPE IE = FG + 4" 5" LAYER OF 3/4" CLEAN CRUSHED ROCK 4" THICK CHOKER COURSE OF 3/8" PEA GRAVEL 18" THICK LAYER OF ENGINEERED SOIL; *SEE NOTE BELOW 3.0" 6.0" PONDING DEPTH 6.0" FREEBOARD *BIOFILTRATION "ENGINEERED SOIL" LAYER SHALL BE EVENLY MIXED COMPOSITION OF WASHED SAND, SANDY LOAM TOPSOIL, AND HUMIC COMPOST. THE MIX SHALL CONTAIN 65% SAND, 20% TOPSOIL, AND 15% COMPOST OR HARDWOOD MULCH IN ACCORDANCE WITH COUNTY OF SAN DIEGO LID BIOSWALE MEDIA BIO65 CUT SHEET. 0.5' 2" LAYER OF DECORATIVE PEA GRAVEL; REFER TO LANDSCAPE PLANS FOR DETAILS90° ELBOW FG = PER PLAN SPLASH BLOCK OR 2'x2' RIP-RAP PER SDRSD D-4; ROCK CLASS = NO. 2, T = 1.1 FT AT ROOF DOWNSPOUT OUTLET 6" BASE LAYER OF NO. 6 GRAVEL DEEPENED FOOTINGCONNECT TO PVT STORM DRAIN; SEE GRADING PLAN FOR CONTINUATION ROWCLPL 5.0' DEDICATION 5.0'5.0'15.0'15.0' 40.0' (1-2%)(1-2%)(3-4%) EX. 6" PCC CURB AND GUTTER EX. 4" PCC SIDEWALK PROP. 8" DR 18 PVC WATERMAIN EX. 8" VC SEWER MAIN PER DWG 118-9 EX. 1.5" GAS PER DWG 402-6 PER DWG 549-9 NOTE: -ALL AGGREGATE MUST BE CLEAN/WASHED AND FREE OF FINES (SAND, SILT, ETC.) -THE PAVERS SHALL NOT BE SEALED ONCE THE VOID FILLER HAS BEEN ADDED -EACH COURSE SHALL BE VIBRATORY COMPACTED BEFORE PLACEMENT OF NEXT COURSE -NO IMPERVIOUS LINER OR FILTER FABRIC IS TO BE USED -SPECIAL APPROVAL REQUIRED FOR USE IN HIGHLY EXPANSIVE SOIL-SUBDRAIN MAY BE REQUIRED -SLOPE SUBGRADE AWAY FROM STRUCTURES AT 5.0% MIN. FOR 10-FT MIN. -BASE LAYER OF NO. 57 MATERIAL AND SUBGRADE SOIL LAYER SHALL BE COMPACTED TO AT LEAST 95% RELATIVE COMPACTION STORAGE LAYER - MIN. 4" THICK OF (NO. 2) GRAVEL (40% VOID RATIO) CHOKER COURSE - MIN. 6" THICK (NO.57) CRUSHED ROCK GRAVEL BASE MATERIAL BEDDING COURSE - MIN. 1" THICK OF (NO.8) SAND BUILDING DEEPENED FOOTING 1.0' MIN BELOW BOTTOM LAYER OF GRANULAR MATERIAL PCC RIBBON GUTTER; SEE DETAIL THIS SHEET VOID FILLER-1 8" TO 3 8" (NO.8) AGGREGATE IN VOIDS 3.15 " THICK PERVIOUS PAVERS W/ MIN. 38" VOID; SEE LS PLANS DWG 549-9L FOR DETAILS SLOPE BOTTOM OF PERVIOUS PAVER LAYER AWAY FROM BUILDING FOOTING; SEE NOTE BELOW COMPACTED SOIL SUBGRADE 1%-5% 5% CL 10.0'2.0' 5% 2.0'2.0' 4" PVC PIPE THROUGH DEEPENED FLUSH CURB ABOVE STORAGE LAYER; 2 LF BOTTOM OF PROPOSED 520-C-2500 PCC DEEPENED FLUSH CURB; 1.0' BELOW BOTTOM LAYER OF GRANULAR MATERIAL NOTE: -ALL AGGREGATE MUST BE CLEAN/WASHED AND FREE OF FINES (SAND, SILT, ETC.) -THE PAVERS SHALL NOT BE SEALED ONCE THE VOID FILLER HAS BEEN ADDED -EACH COURSE SHALL BE VIBRATORY COMPACTED BEFORE PLACEMENT OF NEXT COURSE -NO IMPERVIOUS LINER OR FILTER FABRIC IS TO BE USED -SPECIAL APPROVAL REQUIRED FOR USE IN HIGHLY EXPANSIVE SOIL-SUBDRAIN MAY BE REQUIRED -SLOPE SUBGRADE AWAY FROM STRUCTURES AT 5.0% MIN. FOR 10-FT MIN. -BASE LAYER OF NO. 57 MATERIAL AND SUBGRADE SOIL LAYER SHALL BE COMPACTED TO AT LEAST 95% RELATIVE COMPACTION CHOKER COURSE - MIN. 6" THICK OF (NO.57) CRUSHED ROCK GRAVEL BASE MATERIAL BUILDING DEEPENED FOOTING 1.0' MIN BELOW BOTTOM LAYER OF GRANULAR MATERIAL CAST-IN-PLACE 520-C-2500 PCC EDGE MIN 4" WIDE MORTAR OR POLYMER ADHERED PAVERS TO TOP, TYP. VOID FILLER-1 8" TO 3 8" (NO.8) AGGREGATE IN VOIDS 3.15" THICK PERVIOUS PAVERS W/ MIN. 3 8" VOID; SEE LS PLANS DWG 549-9L FOR DETAILS SLOPE BOTTOM OF PERVIOUS PAVER LAYER AWAY FROM BUILDING FOOTING; SEE NOTE BELOW COMPACTED SOIL SUBGRADE 1%-5% 4.0' STORAGE LAYER MIN. 2" THICK OF (NO. 2) GRAVEL (40% VOID RATIO)5% BEDDING COURSE - MIN. 1" THICK OF (NO.8)SAND 5% 1%-5% X MI N 2 " 4" PVC PIPE THROUGH DEEPENED FLUSH CURB ABOVE STORAGE LAYER; 2 LF BOTTOM OF PROPOSED 520-C-2500 PCC DEEPENED FLUSH CURB; 1.0' BELOW BOTTOM LAYER OF GRANULAR MATERIAL PL APN: 204-070-28-00 UNIT 8 FF = 47.1 PAD = 46.41.8' 6.0' 14.0' 4.0'X 2.0%0.3' 46.3 TW (44.4 BW@EG) 49.9 TW 46.4 BW@FG BMP #15 48.9 FG EXISTING GRADE PROPOSED FENCING PER SEPARATE LANDSCAPE PLAN 549-9L PROPOSED PERVIOUS PAVERS SEE DETAIL THIS SHEET PROPOSED RAISED PLANTER BIOFILTRATION BMP (TYP.); SEE DETAIL THIS SHEETPROPOSED RETAINING WALL PER SDRSD C-03 HMAX = 3.0' DEEPENED FOOTING X REMEDIAL GRADING CUTREMEDIAL GRADING CUT 0.5'0.2' EXISTING BUILDING 4.9' APPROX. EXISTING BUILDING FOOTING; CONFIGURATION UNKNOWN 1:1 PROPOSED LANDSCAPED SWALE X APN: 204-010-08-001.8' 6.0' 14.0' 4.0' PL 2.0%46.3 TW (44.3 BW@EG) 49.9 TW 46.4 BW@FG BMP #7 48.9 FG PROPOSED FENCING PER SEPARATE LANDSCAPE PLAN 549-9L PROPOSED PERVIOUS PAVERS SEE DETAIL THIS SHEET PROPOSED RAISED PLANTER BIOFILTRATION BMP (TYP.); SEE DETAIL THIS SHEET PROPOSED RETAINING WALL PER SDRSD C-03 HMAX = 3.0 DEEPENED FOOTING X UNIT 2 FF = 47.1 PAD = 46.4 0.5'0.2' EXISTING BUILDING EXISTING GRADE REMEDIAL GRADING CUT 0.3' 1.5' APPROX. EXISTING BUILDING FOOTING; CONFIGURATION UNKNOWN 1:1 PROPOSED LANDSCAPED SWALE UNIT 1 FF = 47.1 PAD = 46.4 PL 5.0' DEDICATION 5.0' VARIES TYLER STREET EXISTING GRADE REMEDIAL GRADING CUT SEE DWG 549-9 FOR PROPOSED IMPROVEMENTS GLIP = 45.7 GLIP = 45.7 UNIT 5 FF = 46.4 PAD = 45.7 1%-5%1%-5% 24.0' EXISTING GRADE PROPOSED PERVIOUS PAVERS SEE DETAIL THIS SHEET PROPOSED PCC RIBBON GUTTER SEE DETAIL THIS SHEET PROPOSED PERVIOUS PAVERS SEE DETAIL THIS SHEET DEEPENED FOOTING DEEPENED FOOTING UNIT 11 FF = 46.4 PAD = 45.7 18.0' PROPOSED BUILDING OVERHANG PROPOSED BUILDING OVERHANG EXISTING GRADE REMEDIAL GRADING CUT UNIT 4 FF = 46.4 PAD = 45.7 UNIT 3 FF = 47.1 PAD = 46.4 14.2' 3.5'3.5' VARIES 7.2' 49.4 TW 46.2 BW@FG BMP #10 48.4 FG 49.2 TW 46.0 BW@FG BMP #11 48.2 FG PROPOSED PERVIOUS PAVERS SEE DETAIL THIS SHEET EXISTING GRADE REMEDIAL GRADING CUT PL PL 5.0' DEDICATION 5.0' APN: 204-010-10-00 TYLER STREET (43.2 EG) X 46.4 FLGRADE BREAK 45.8 FL GRADE BREAK 45.5 FL 0.7%2.0%0.7% 0.0% 44.6 BOT 44.6 BOT 43.9 BOT 0.0%43.9 BOT 0.0% PROPOSED VEHICULAR PERVIOUS PAVERS SEE DETAIL THIS SHEET 12"X12" BROOKS BOX 45.1 TG PL PL 5.0' DEDICATION 5.0' APN: 204-010-10-00 TYLER STREET (43.0 EG) X PROPOSED PEDESTRIAN PERVIOUS PAVERS SEE DETAIL THIS SHEET 2:1 MAX 12"X12" BROOKS BOX 45.5 TGX 46.7 FL 45.7 FG 45.4 BOT 0.5% GRADE BREAK 45.9 FG GRADE BREAK 46.4 FG 44.7 BOT 0.0% 1.2%1.2% 0.0% 44.7 BOT 45.4 BOT 0.5% 0.0% PROPOSED 520-C-2500 PCC 6" WIDE, 30" MIN DEPTH DEEPENED FLUSH CURB PROPOSED 520-C-2500 PCC 6" WIDE, 30" MIN DEPTH FLUSH CURB SEE DWG 549-9 FOR PROPOSED IMPROVEMENTS SEE DWG 549-9 FOR PROPOSED IMPROVEMENTS EXISTING GRADE REMEDIAL GRADING CUT EXISTING GRADE REMEDIAL GRADING CUT PROPOSED 6" CURB PER SDRSD G-01 4" PVC PIPE THROUGH DEEPENED FLUSH CURB ABOVE STORAGE LAYER; 2 LF 4" PVC PIPE THROUGH DEEPENED FLUSH CURB ABOVE STORAGE LAYER; 2 LF BERM @ TOP OF SLOPE PER DETAIL THIS SHEET PL 3.5' 10.1' UNIT 6 FF = 46.4 PAD = 45.72:1 MAX APN: 204-010-10-00 6.0' (43.2 EG) 49.2 TW 45.7 BW@FG BMP #1 48.2 FG PROPOSED RAISED PLANTER BIOFILTRATION BMP (TYP.); SEE DETAIL THIS SHEET SD OUTLET CUTOFF WALL AND RIP RAP PER DETAIL THIS SHEET X EXISTING GRADE REMEDIAL GRADING CUT 0.6' 4" SD OUTLET PIPE BERM @ TOP OF SLOPE PER DETAIL THIS SHEET 12 " 2.0' 6" 6" 6" 2.0' 6" 520-C-2500 PCC 6" STORM DRAIN PIPE OUTLET 2'X2' ROCK RIP RAP PER SDRSD D-40, NO. 2 BACKING, 1.1-FT THICK FLUSH CURB 1.0' BELOW FS FS PER PLAN 2:1 4"X4"X4" TEE 4" PVT. PVC SD PIPE @ 1% MIN 4. 0 " 0.5' 6.0' 0.5' 2:1 MA X PL TOP OF SLOPE 45.7 FG BOTTOM OF BERM 45.4 FG J:\ACTIVE JOBS\4070 NORUM-CARLSBAD-Tyler Street\CIVIL\DRAWING\GRADING PLANS TYPICAL DETAIL - VEHICULAR PERVIOUS PAVERS NOT TO SCALE TYPICAL DETAIL - PCC RIBBON GUTTER NOT TO SCALE TYPICAL DETAIL - RETAINING WALL NOT TO SCALE PLAN VIEW - SECTION KEY MAP SCALE: 1" = 60' TYPICAL DETAIL - RAISED PLANTER NOT TO SCALE TYPICAL SECTION - TYLER STREET NOT TO SCALE TYPICAL DETAIL - PEDESTRIAN PERVIOUS PAVERS NOT TO SCALE REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. TYLER STREET HOMES CT 2024-0001 549-9A GR 2024-0023 PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4070 9 SECTION C-C NOT TO SCALE SECTION B-B NOT TO SCALE SECTION A-A NOT TO SCALE SECTION D-D NOT TO SCALE SECTION F-F NOT TO SCALE SECTIONS AND DETAILS 4 SECTION G-G NOT TO SCALE SECTION H-H NOT TO SCALE SECTION E-E NOT TO SCALE TYPICAL DETAIL - MODIFIED CUTOFF WALL NOT TO SCALE TYPICAL DETAIL - BERM @ TOP OF SLOPE NOT TO SCALE NF NF I I tiJ,---CQ--'----L.11----.1--Jl_~ l+J'i'--T?t-r--r+-,--,----'F-ffl .... -. I I 7 I -I I ____ ]_ ------i.--,1- I • I --' -,_!.-•-;:: ---c -I --==::1------==.;-~ '---cc.,~\~ I I '1 T rn: --I -, 11-111==111 11 I I ' I •_II ITT' II ,. II ,. II• -1 -1 -1 -1 I I J.U; ill fil.=lJ;-- I I I I l... --... --... --... --... --... --... --... I I '1 / --... --... / '--... / '--... I / --... / --...... / / / / / / / / I I I I I I I ) --I 1:-=:::ln~LJ~?itir,:·:rr u=·-_ =~= -~\-----e._--:-;-; -~rn-n~ I I I -i I I I -!-- )l; -1 E I I I t----+--+-----------1------i---t------r-----i ~ 11 CITY OF CARLSBAD I LJ DA 1E INITIAL DA 1E INITIAL DAlE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OlHER APPROVAL CITY APf'ftOVAL GRADING PLANS FOR: APPROVED: ENGINEERING MANAGER DWN BY: __ _ CHKD BY: __ RVWD BY: JASON S. GELDERT RCE 63912 EXPIRES 9 30 26 DAlE PROJECT NO. I DRAWING NO. Docusign Envelope ID: D48B54F8-556D-45B8-ABE2-69EB8EFFFC77 5/14/2025 REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. TYLER STREET HOMES CT 2024-0001 549-9A GR 2024-0023 PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4070 9 DETAILS 5 NF NF C r: [36' l I 3'0" • L I 4 96" 8'0" 4" SCH 40 PVC OVERFLOW DRAIN PIPE 1-1 3 A =:J 2 AL-FORMED AND FULLY WELDED 1/8" ASTM B209 5052-H32 MARINE GRADE ALUMINUM. WALL REINFORCEMENT SYSTEM AROUND INSIDE PERIMETER. (NOT SHOWN) PLANTER IS DESIGNED FOR NO MORE THAN 130LBS P.C.F. SATURATED SOIL DENSITY. CUSTOMER APPROVAL· SIGNATIJRE AUTI<ORllEI TOURl'lfiOl. mEWORl(S TO "A!'IUPAUUllE T~~ POO!lUCT AS l >IOW!'I C 4 96" C 8'0" r [48' l A 4'0" I l} 4" SCH 40 PVC OVERFLOW DRAIN PIPE 3 JOI =:J A 2 AL-FORMED AND FULLY WELDED 1/8" ASTM ----"' B209 5052-H32 MARINE GRADE ALUMINUM. "' WALL REINFORCEMENT SYSTEM AROUND INSIDE PERIMETER. (NOT SHOWN) PLANTER IS DESIGNED FOR NO MORE THAN 130LBS P.C.F. SATURATED SOIL DENSITY. CUSTOMER APPROVAL· IIGNATIJRi AUTI<ORllES TOURl'IE,Ol. mEWORl(S TO ""-!'IUFb.Ul.OlE T~E PROOUCT b.S S>IOW!'I C B (CAN BE TRIMMED DURING FIELD INSTALLATION TO FIT REQUIREMENTS)~ OVERFLOW DRAIN FLEXIBLE GASKET, 55 PLATES, SEALANT, AND 55 HARDWARE FOR B B (CAN BE TRIMMED DURING FIELD INSTALLATION TO FIT REQUIREMENTS)~ OVERFLOW DRAIN FLEXIBLE GASKET, 55 PLATES, SEALANT, AND SS HARDWARE FOR B A NOTES: \ \ 1-4" SCH 40 PVC END CAP ,, ~4 " SCH 40 PERFORATED PVC DRAIN PIPE [TO BE COVERED WITH FILTER FABRIC PROVIDED BY OTHERS) SECTION A-A PART NUMBER: WFT-AL963642-SA L AAMA 2604 POLYESTER POWDER COAT WITH ZINC-FREE EPOXY PRIMER l [42"] 31611 4" SCH 40 PVC OUT HOLDING AND SEALING AROUND PIPE - [ALL PARTS INCLUDED)~:/·,,--- / \ I \ TOP DETAIL DETAIL B SCALE 1 4 OTournesol SITEWORKS •~.in F~RFR STRFFT. l!t.'l(X',J C':ITY. CA Q45B7 S~E OW!,IJO: WFT-AL963642-SUB TllU RIORETFNTION Pl ANTER WITH DRAINAGE ASSEM[ll_Y, MARINE GRADE ALUMINUM, STANDALONE UNIT, 96 X36X42: A A NOTES: \ \ 1-4" SCH 40 PVC END CAP ,, ~4" SCH 40 PERFORATED PVC DRAIN PIPE [TO BE COVERED WITH FILTER FABRIC PROVIDED BY OTHERS) SECTION A-A PART NUMBER: WFT-AL964842-SA L AAMA 2604 POLYESTER POWDER COAT WITH ZINC-FREE EPOXY PRIMER l [42"] 31611 ~c~J 4" SCH 40 PVC OUT HOLDING AND SEALING AROUND PIPE - [ALL PARTS INCLUDED)~:/,,,,,--- / \ I \ TOP DETAIL DETAIL B SCALE 1 4 OTournesol SITEWORKS •~.in FARFR STRFFT. l!t.'l(X'-J C':ITY. CA Q45B7 S~E nw1,r.1a: WFT-AL964842-SUB Tlll_E• RIORETFNTION PLANTER WITH DRAINAGE ASSf:M[ll_Y, MARINE GRADE ALUMINUM, STANDALONE UNIT, 96 X 48X42: A 2. ALL DIMENSIONS ARE NOMINAL, ACTUAL SIZE MAY VARY +/-1/8" UNLESS SPECIFIED OTHERWISE DIMENSIONS /\RE IN INCHES UNLESS Al'PRO'JED BY: GKO~ETRA DRAW/I BY, R.1.K::UNE DATE: 12,118,'WB SHEET 1 OF 1 2. ALL DIMENSIONS ARE NOMINAL, ACTUAL SIZE MAY VARY +/-1/8" UNLESS SPECIFIED OTHERWISE DIMENSIONS ARE IN INCHES UNLESS Al'PRO'JED Bf, GKO~ETRA DRAW/I BY, R.1.K::UNf DATE: 12,'13!20B SHEET 1 OF 1 REM ·www.remti.l1~r.~.com Revel l."'nviromnental Manufacturing Inc. .,ak'S@remfil!rnwun (888) 526-473G Llc. No. 857410 Nonhtm California 960-8 D<.:tr1Jil Av~mlt' Cornx wd, C;,lif-Orni;, 9451 8 I': (925) 676-4736 F: ('.)25) 676,8676 Southern California 2) IO S1Jt11I, Gr~ndJ\vn •u~ S<lnt;, .An;,, C;,JifOrni'I :)?,705 I' (71-1) 557-2676 F: (71/4) 557,2679 Overflow Bypass TYPICAL TRENCH DRAIN Standard Size Ditnensions Nol all mmh:l and e<i:1.c;o. arc lisl:cd here Model: TT2-PERF-FTC TDAMS(S)-TDAM8(10)-TDAM12(5)· PE RF-FTC PERF-FTC PERF-FTC Width: 4" 5" 8" 12" Height: 4" 5" 10" 5" Trench 4" 5" 8" 12" Width • ' • • Est. Bypass (CFS) {CFS) {CFS) {CFS) Max .11 .28 .86 .65 Treatment {CFS) {CFS) {CFS) {CFS) Rate: * Note: Overflow bypass will vary depending upon the depth of each trench drain. Removable Cap Stainless Steel Screen TDAM Stainless Steel Housing TDAM15(5) installed TDAM12 (5)-PERF-FTC TDAM (TT2}-PERF-FTC for rounded bottom 4" fD trench drains. 4 REM TRITON TDAM -PERF -FTC Product Overview: REM designed the TRITON TDAM-PERF-FTC Fitter Series to provide a highly adaptable solution that allows the flexibility to maximize the filter treatment flow rates and pollutant capturing capacity in trench drain and shaffow type drains applications. The TRITON TDAM-PERF-FTC Series uses Perforated Stainless Steel (PERF) Screen that is designed to capture debris, trash and sediment while sustaining very high treatment rates as a Full Trash Capture System as per the 5mm CSWRCB specification. TRITON TDAM-PERF-FTC Filters can be sized to fit most industry standard trench drains, parkway drains, shallow structures, and catch basins. They are sized to spec and scalable for all different lengths and applications. Media strategy may also be optimized for specific polfutant concerns. Notes: • TDA M ho1Jsings ore constructed utilizing Type 304 .16go. Stainless Steel, with 1 "and 2"welded square openings. • Hemovub/e cartridge tops und bottoms are constructed utilizing over 90% recycled ABS Plastic or fiberglass, • Filter ~'Cfeen utilizes 22yu, l)'pe 3()4Stain/ess Steel perfomtion. • Perforated Stainless Steel is configured with a 4.8mm apenin,qs, havin!J a S1% Open Area /Or excellent flow rates comparalive toils size. • REM TRITON jilter cartridges can be removable /Or ease of cleaning anri maintenance • Filter designs include a high flaw overflow bypass to climifwle pooliflg or floodin,q duriflfJ }wavy rain eve111s. • OptiotJal Stainless Steel Cartridge housings are capable of horm·ng an absorbent meriia 1/ ever 1·equired, with no retmfitting or modifications needed. • Maintenance information and replacement REM Media Packs are available 11pon request by contacting REM at sales@remjilters.com or (888) 526-4736, • Made in the USA. (Lengths: 4" up to 10') (Standard Heights: 3", S", 10") 3 C B A QTHERWl'.)E )PECIFIED APP.WVALOATE: 12/20/2·J23 2 4 4 3 2 1 Cl.lSTnMER A""RD\/U ,mNAllJKU,lJIHU!<Jlt', lllU<Nc'>OL SU~WUKK'>.1 0 MJ\NlJH,ll UKt I Ht PHOIJUCI A'> >HOWN 72" 6'0" r [ 48"] A 4'0" I l} 4" SCH 40 PVC OVERFLOW DRAIN PIPE (CAN BE TRIMMED DURING FIELD INSTALLATION TO FIT REQUIREMENTS)~ 1JII QA AL-FORMED AND FULLY WELDED 1/8" ASTM~ 8209 5052-H32 MARINE GRADE ALUMINUM. WALL REINFORCEMENT SYSTEM AROUND INSIDE PERIMETER. (NOT SHOWN) PLANTER IS DESIGNED FOR NO MORE THAN 130LBS P.C.F. SATURATED SOIL DENSITY. FLEXIBLE GASKET, SS PLATES, SEALANT, ANO SS HARDWARE FOR HOLDING ANO SEALING AROUND PIPE "' ;--OVERFLOW DRAIN /// l (ALL PARTS INCLUDED)~, /,..--'/ I I 4" SCH 40 PVC_/ END CAP -s \ I '-. / [42"] 3'6" ~~c~J \__4" SCH 40 PERFORATED PVC DRAIN PIPE -\_4 " SCH 40 PVC OUT (TO BE COVERED WITH FILTER FABRIC PROVIDED BY OTH ERS) )( I \ TOP DETAIL SECTION A-A -3"7 j DETAIL B NOTES: PART NUMBER: WFT-AL724842-SA ~ I 1. AAMA 2604 POLYESTER POWDER COAT WITH ZINC-FREE EPOXY PRIMER 2. ALL DIMENSIONS ARE NOMINAL, ACTUAL SIZE MAY VARY+/-1/8" UN LESS SPECIFIED OTHERWISE 4 3 2 SCALE I 4 OTournesol SITEWORKS 29SO F"8ER ST~EET, _MON CITY, 0 945111 S~E DW6 ND, WFT-AL724842-SUB DIMEN'.;;IUNSARE IN INCHE) UNLESS OTHERWISE SPECIFIED BIORETENTION PLANTER W ITH DRAINAGE ASSEMBLY, MARINE GRADE ALUMINUM, STANO/\LONE UN IT, 72 X 48 X 42 APPROVED SY. ~WOISTRA AP?RCVALOATE: 12/lJ/2023 OP.A'MN 6v. RMCCUJC O~TE: 12/18/2023 1 SH•~T 1 OF 1 QTHERWl'.)E )PECIFIED APP.WVALOATE: 12/20/2·J23 3 2 BIO-RETENTION PLANTER LEGEND PLANTER ID MANUFACTURER MODEL NO. & DESCRIPTION COLOR FINISH QUANTITY C DMA-1 DMA-9 TOURNESOL WFT-AL723642-S. 72"LX 36"W X 42'H START (Sl TBD TBD 2 DMA-1, DMA-9 TOURNESOL WFT-AL723642-M, 72"L X 36"W X42"H , MIDDLE IMI TBD TBD 2 DMA-1, D MA-9 TOURNESOL WFT-AL723642-E, 72"LX 36"W X 42'H, END IEI TBD TBD 2 DMA-2, DMA-7. DMA-10, DMA-15, DMA-17 TOURNESOL WFT-AL723642, 72'L X 36'W X 42"H, STAND ALONE (SA) TBD TBD 9 DMA-3, DMA-4, DMA-5, DMA-11, DMA-12, DMA-13, DMA-18 TOURNESOL WFT-AL963642. 96'L X 36'W X 42"H STAND ALONE ISA) TB□ TBD 7 B DMA-6 DMA-14 TOURNESOL WFT-AL964842 96'L X 48'W X 42"H STAND ALONE ISAl TBD TBD 2 DMA-8, DMA-16 TOURNESOL WFT-AL724842, 72'L X 48'W X 42"H, STAND ALONE (SA) TBD TBD 2 DMA-1, D MA-9 TOURNESOL SCP-K48B, SCOOP CONNECTION KIT FOR 48" WIDE PLANTERS TBD TBD 4 DHCC, CUSTOM DRAIN HOLES, MANUFACTURER TO DMA-2, DMA-7. PROVIDE SHOP DRAWINGS TO BE APPROVED BY THE DMA-10 DMA-15 TOURNESOL CONTRACTOR TBD TBD 6 A t----+--+--------------,t-----+---+-----+---t ~ 11 CITY OF CARLSBAD I LJ GRADING PLANS FOR: APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63912 EXPIRES 9 30 26 DAlE DAlE INillAL ENGINEER OF WORK REVISION DESCRIPTION DA 1E INillAL DAlE INITIAL DTHER APPROVAL CITY APf'ftOVAL DWN BY: CHKD BY: __ _ RVWD BY: PRO.ECT NO. DRAWING NO, Docusign Envelope ID: D48B54F8-556D-45B8-ABE2-69EB8EFFFC77 5/14/2025 REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. TYLER STREET HOMES CT 2024-0001 549-9A GR 2024-0023 PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4070 9 DETAILS 6 NF NF C - B - A C - B - A 4 I 3 I 2 I 1 ,lt,NAIUKl AUIHU~lllS IUU'NeSUL SIIHl,UKKs·1 U MANU>A[I UHl IHC PKUIJUU A> SHUWN [72"] 6'0" I. AL-FORMED AND FULLY WELDED 1/8" ASTM~, ~ B209 5052-H32 MARINE GRADE ALUMINUM. "'· A WALL REINFORCEMENT SYSTEM AROUND INSIDE [36" • 1JE: =:J PERIMETER. (NOT SHOWN) I 3'0" PLANTER IS DESIGNED FOR NO MORE THAN L 130LBS P.C.F. SATURATED SOIL DENSITY. ' 4" SCH 40 PVC OVERFLOW DRAIN PIPE (CAN BE TRIMMED DURING FIELD INSTALLATION TO FIT REQUIREMENTS)~ ;-OVERFLOW DRAIN II I . \ I -/-....8 ...... 1~111 I~ . ,::: V l [42"] 3'6" ~c~J FLEXIBLE GASKET, SS PLATES, SEALANT, AND SS HARDWARE FOR HOLDING AND SEALING AROUND PIPE (ALL PARTS INCLUDED) 4" SCH 40 PVC_j END CAP \__4 " SCH 40 PERFORATED -\ PVC DRAIN PIPE ~4" SCH 40 PVC OUT (TO BE COVERED WITH FILTER FABRIC PROVIDED BY OTHERS) TOP DETAIL SECTION A-A f--3'' -I NOTES: 1" PART NUMBER: WFT-AL723642-SA AAMA 2604 POLYESTER POWDER COAT WITH ZINC-FREE EPOXY PRIMER DETAIL B SCALE I c 4 0 T OU rn esol ,m t: BIORETENTION PLANTER WITH DRAINAGE ASSEMBLY, SITE WO R.. KS MARINEGRADEALUMINUM,STANDALONEUNIT_.72 X36X 42 29SO FABER snEET, _'tJJON CITY, c~ 94>61 s9E lowGNo, WFT-AL723642-SUB 1. 2. ALL DIMENSIONS ARE NOMINAL, ACTUAL SIZE MAY VARY+/-1/8" UNLESS SPECIFIED OTHERWISE DIMENSIOtJS ARE IN INChES UNLESS APPROVEC av: ~KOOISTRA DRAWN R~: RMCCUIC LI~ I>, ll/1"/1U1' IS/1HT 1 OF 1 I [36"] A 3'0" li NOTES: 4 4 :n·] 6'0" I I I I I A I I . . . . • . . . I \ '-4" SCH 40 PERFORATED '-4" RUBBER PVC DRAIN PIPE COUPLER (TO BE COVERED WITH FILTER FABRIC PROVIDED BY OTHERS) SECTION A-A PART NUMBER: WFT-AL723642-M 1. AAMA 2604 POLYESTER POWDER COAT WITH ZINC-FREE EPOXY PRIMER 3 3 I I 2 2 AL-FORMED AND FULLY WELDED 1/8" ASTM~\ B209 5052-H32 MARINE GRADE ALUMINUM. ' WALL REINFORCEMENT SYSTEM AROUND INSIDE PERIMETER. (NOT SHOWN) PLANTER IS DESIGNED FOR NO MORE THAN 130LBS P.C.F. SATURATED SOIL DENSITY. j [ 12"] 1'0" l I--[3o'] --I I 2'6" I \~r 1 \ / [42"] V J TOP DETAIL f----3 '' ----j 1" OTHERWISE SPECIFIED ~e>HLVALLIHc 'LJjn/1□1; I I CUSTOMER Af'f'RO\IAL 1 1 '>lGNl\llJRE Atmi0illZES TOU'lNE>OL SITEW0RK> TO MANlJfACTURE IBE PRODUCT A> '>H0WN 0 T OU rn esol mlf~IORETENTION PLANTER WITH DRAINAGE ASSEMBLY, SITE WO R.. KS MARINEGRADEALUMINUM,MIDDLEUIJIT,72X36X -12 mo FABER ST~EET, _'N!Oh' CITY, CA 94581 S~E IOWSNO, WFT-AL723642-M-SUB 2. ALL DIMENSIONS ARE NOMINAL, ACTUAL SIZE MAY VARY+/-1/8" UNLESS SPECIFIED OTHERWISE DIMENSIONS ARE IN INCI-.ES UNLESS APPROVED iv: HOOlSTRA DRA'NN B'; RMCCUJC 0~TE: 11Jrn.l2on IS/1EET 1 OF 1 OTHERWISE SPECIFIED ~Pi'HCVALOAE 12/2-Jll□B 4 I 3 I 2 I 1 C C -- B B - A A C C -- B B - A A 4 I [72• l 6'0' I. [36'] + I 1JE: =:J 3'o· L 3 A I 2 AL rORMED AND FULLY wELDED 11s· AST,t.t--,,-..__ B209 5052-H32 MARINE GRADE ALUMINUM, w ALL REINFORCEMENT SYSTEM AROUND INSIDE PERIMETER. (NOT SHOwN) PLANTER IS DESIGNED FDR ND MORE THAN 130LBS P C.F. SATURATED SDIL DENSITY. I 1 COST[IO APf'R[J\l~L• Slli\lAll.M: AllflOUZES T[JJlltCII. SITEIICRn TD IWIJFACTLRE Tl£ ~orocT AS Sff[JI/N. 4' SCH 40 PVC OVERFLO\/ DRA[N P[PE <CAN BE TRIMMED DURING FIELD [NSTALLATr□N TD FIT REQU[REMENT~ □VERFLD\/ DRAIN I ..... l vlll I \__4' SCH 40 PERFORATED 1 [42• l 3'6' ~c~l FLEXIBLE GASKET, SS PLATES, SEALANT, AND SS HARDI/ARE FDR HOLDrNG AND SEAUNG AROUND P[PE <ALL PARTS [NCLUDED 4' RUBBER COUPLER PVC DRA[N P[PE 4' SCH 40 PVC OUT NOTES: (TD BE COVERED \/ITH FILTER FABRIC PROVIDED BY OTHERS) SECTION A-A PART NUMBER, wFT -AL 723642-E AAMA 2604 POLYESTER POI/DER COAT \/ITH ZINC-FREE EPOXY PRIMER TOP DETAIL ---3'-I 1' DETAIL B SCALE 1 : 4 I ourneso Bl□RETENT!lfi PLANTER VITH DRAINAGE ASSEMBLY, 0 -r: I ""' s I T E W o R K s MARINE GRADE ALUMINUM, END UNIT, 71 X 36 X 41 c!'Jll FAfER SlR[ET, IMJUN □TY, CA ~4~87 '~'I"""' \/FT-AL723642-E-SUB I A 1 2. ALL DIMENSI□NS ARE NOMINAL, ACTUAL SIZE MAY VARY +/-1/8' UNLESS SPECIFIED DTHER\/ISE IIIHENSLD~§_, AR_E _ _[N lNCf-CS UNLESS 11THt RI.""- llff!MD BY• [;lllIJISTRA APPmVlt. om, 12120/2023 11!~\IN BY• RMCOJIE DATEi 12/Jij,12023 l"'l' OF 1 4 4 I, I I i------[n"] ------i 6'0" [36 ] l 3'0" 1 "o"'-111_,__1'----------~~I LI--~ 3 3 A /-4" SCH 40 PVC CLEANOUT PIPE _,/ (CAN BE TRIMMED DURING FIELD I I 2 2 AL-FORMED AND FULLY WELDED 1/8" ASTM--,,~ B209 5052-H32 MARINE GRADE ALUMINUM. -.., WALL REINFORCEMENT SYSTEM AROUND INSIDE PERIMETER. (NOT SHOWN) PLANTER IS DESIGNED FOR NO MORE THAN 130LBS P.C.F. SATURATED SOIL DENSITY. I I ClJSl0!.:ER Al'n OVAl • 1 S.GNA TURE ALITH0RILES TOORNE50L SITEW0RK> TO MAJl:lJFACTlJIIE THE PRODUCT M, '>H0WN. \ 4" SCH 40 PVC CLEAN OUT I // INSTALLATION TO FIT REQUIREMENTS) NOTES: \ /' = , 11 . . . . . . . . . . J / \ / 1__4" SCH 40 PERFORATED L LONG 4" SCH 40 PVC DRAIN PIPE PVC ELBOW (TO BE COVERED WITH FILTER FABRIC PROVIDED BY OTHERS) SECTI ON A-A PART NUMBER: WFT-AL723642-S 1. AAMA 2604 POLYESTER POWDER COAT WITH ZINC-FREE EPOXY PRIMER 2. ALL DIME NSIONS ARE NOMINAL, ACTUAL SIZE MAY VARY +/-1/8" UNLESS SPECIFIED OTHERWISE 4 I 3 I TOP DETAIL :-3•j j ~I~ 2 I ourneso BIORETENTION PLANTER W ITH DRAINAGE ASSEMBLY, 0 1. I nm SITE WO R. KS MARINEGRADEALUMINUM,STARTERUNIT_.72X36X42 <930 HBE's STREET, U~ION CITY, CA 940!1 sr I OWONO, WFT-Al723642-S-SUB DIMENSIONS ARE IN INCHES UNLESS APPRD\'EDBY: GO0ISlRA. OTHERWISE SPECIFIED Af'PROVAL DAH: 11,'20,'2013 I PMWN BV; ~MCClJ,~! □ ATE: ll.Jl~/202'! ISHEET 1 OF 1 C B f--- A C ~ B ~ A PLSA 1,...-, PLSAENGINEERING.COM t----+--+--------------,t----+---+----+---1 ~ 11 CITY OF CARLSBAD I LJ DA 1E INITIAL DA 1E INITIAL DAlE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OlHER APPROVAL CITY APf'ftOVAL GRADING PLANS FOR: APPROVED: ENGINEERING MANAGER OWN BY: ---1 CHKD BY: __ RVWD BY: . JASON S. GELDERT RCE 63912 EXPIRES 9/30/26 DAlE PRO.ECT NO. I DRAWING NO. Docusign Envelope ID: D48B54F8-556D-45B8-ABE2-69EB8EFFFC77 5/14/2025 CAR L S B A D V I L L A G E D R SITE T Y L E R S T I N T E R S T A T E 5 J:\ACTIVE JOBS\4070 NORUM-CARLSBAD-TYLER STREET\CIVIL\DRAWING\GRADING PLANS\4070-CV-GP-07-SWPPP COVER.DWG N.T.S. Best Management Practice* (BMP) Description Construction Activity CASQA Designation BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE Pollution Control BMPs Waste Management and Materials Management BMPs Non-Storm Water Control BMPs Tracking BMPs Sediment Control BMPsErosion Control TELEPHONE NO.: (949) 678-4927 TELEPHONE NO.: (949) 678-4927 ADDRESS: 2888 LOKER AVENUE EAST, SUITE 220 CARLSBAD, CA 92010 NAME: JOHN NORUM FOR: TYLER STREET DEV LLC MEDIUMHIGH CONSTRUCTION THREAT TO STORM WATER QUALITY (CHECK BOX): ADDRESS: 2888 LOKER AVENUE EAST, SUITE 220 CARLSBAD, CA 92010 NAME: TYLER STREET DEV LLC REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. TYLER STREET HOMES CT 2024-0001 549-9A GR 2024-0023 PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4070 9 TIER 2 SWPPP COVER SHEET 7 THE FOLLOWING GENERAL SITE MANAGEMENT REQUIREMENTS SHALL BE ADHERED TO 9. ALL INACTIVE AREAS MUST BE PROTECTED WITH THE APPROPRIATE EROSION CONTROL 10. PERIMETER PROTECTION AND SEDIMENT CONTROL BMPs WILL BE UPGRADED, IF NECESSARY, 11. ADEQUATE SEDIMENT CONTROL BMPs MUST BE INSTALLED AND MAINTAINED. 12. ADEQUATE BMPs TO CONTROL OFFSITE SEDIMENT TRACKING MUST BE INSTALLED 13. ALL CONSTRUCTION SITES ARE TO MAINTAIN EMERGENCY STOCKPILES OF BMPs ONSITE THROUGHOUT THE YEAR. BMPs MUST BE STOCKPILED AT VARIOUS LOCATIONS THROUGHOUT THE SITE FOR THE DURATION OF THE PROJECT. THE FOLLOWING INCLUDES A PARTIAL LIST 14. THE OWNER/DEVELOPER/CONTRACTOR MUST HAVE AN APPROVED SWPPP AND BE ABLE TO DEPLOY STANDBY BMPs TO PROTECT THE EXPOSED PORTIONS OF THE SITE WITHIN 48 HRS 15. DEPLOYMENT OF PHYSICAL OR VEGETATION EROSION CONTROL BMPs MUST COMMENCE AS SOON AS SLOPES ARE COMPLETED. THE PROJECT PROPONENT MAY NOT RELY ON THE ABILITY TO DEPLOY STANDBY BMP MATERIALS TO PREVENT EROSION OF SLOPES THAT 16. THE AREA THAT CAN BE CLEARED, GRADED, AND LEFT EXPOSED AT ONE TIME IS 17. ALL DISTURBED AREAS THAT ARE NOT COMPLETED AND/OR NOT BEING ACTIVELY GRADED MUST BE FULLY PROTECTED FROM EROSION IF LEFT FOR 14 OR MORE DAYS. 18. ALL TREATMENT CONTROL BMPs MUST BE INSPECTED WEEKLY AND PRIOR TO A FORECASTED RAIN EVENT OF 50% OR GREATER. IN ADDITION, TREATMENT CONTROL BMPs 19. IF SELECTED BMP FAILS DURING A RAIN EVENT, IT MUST BE REPAIRED OR REPLACED AS SOON AS POSSIBLE. 21. THE CITY RESERVES THE RIGHT TO TEMPORARILY STOP WORK ON ANY CONSTRUCTION SITE THAT MAY HAVE THE POTENTIAL TO DISCHARGE DURING A RAIN EVENT DUE TO LACK OF BMPs, PROXIMITY TO AN ENVIRONMENTALLY SENSITIVE AREA, PREVIOUS COMPLIANCE ISSUES, AMOUNT AND DURATION OF RAIN EXPECTED, AND/OR ANY OTHER STORM WATER COMPLIANCE ISSUE. EACH SITE WILL BE EVALUATED ON A CASE BY CASE BASIS TO DETERMINE IF A TEMPORARY 20. ALL CONSTRUCTION WORKERS, INCLUDING SUB-CONTRACTORS, MUST BE TRAINED ON THE IMPORTANCE OF STORM WATER POLLUTION PREVENTION AND BMP MAINTENANCE PRIOR TO 1. ALL PERMANENT AND TEMPORARY EROSION CONTROL PLANTING AND IRRIGATION SHALL BE INSTALLED AND MAINTAINED AS REQUIRED IN THE CITY'S ENGINEERING STANDARDS AND LANDSCAPE MANUAL, CASQA AND THE FOLLOWING: A. SLOPES 6:1 OR STEEPER REQUIRING EROSION CONTROL MEASURES AS SPECIFIED a. STANDARD 1 - COVER CROP /AND EROSION CONTROL MATTING 2. ALL SLOPES SHALL HAVE IRRIGATION INSTALLED AND BE STABILIZED, PLANTED AND/OR HYDROSEEDED WITHIN TEN (10) DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED GRADING PLANS. 3. SHOULD GERMINATION OF HYDROSEEDED SLOPES FAIL TO PROVIDE EFFICIENT COVERAGE OF GRADING SLOPES (90% COVERAGE) PRIOR TO OCTOBER 1, THE SLOPES SHALL BE STABILIZED BY AN APPROPRIATE EROSION CONTROL MATTING MATERIAL APPROVED BY THE PUBLIC WORKS INSPECTOR. 4. LANDSCAPING SHALL BE ACCOMPLISHED ON ALL SLOPES AND PADS AS REQUIRED BY THE CITY OF CARLSBAD LANDSCAPE MANUAL, THE LANDSCAPING PLANS FOR THIS PROJECT OR AS DIRECTED BY THE CITY ENGINEER OR CITY PLANNER. 5. THE OWNER/APPLICANT SHALL ENSURE THAT ALL CONTRACTORS SHALL COORDINATE THE WORK OF THIS CONSTRUCTION SWPPP SHOWN ON ANY GRADING PLANS, LANDSCAPE AND IRRIGATION PLANS, AND IMPROVEMENT PLANS AS REQUIRED FOR THIS PROJECT WORK. OF THE QUANTITIES AND TYPES OF BMPs THAT MUST BE STOCKPILED FOR EMERGENCY DEPLOYMENT. THESE QUANTITIES ARE IN ADDITION TO THE AMOUNT OF MATERIALS THAT OF A PREDICTED STORM EVENT (A PREDICTED STORM EVENT IS DEFINED AS A 50% CHANCE OF RAIN WITHIN A 2-DAY NATIONAL WEATHER SERVICE FORECAST). HAVE BEEN COMPLETED. LIMITED TO THE AMOUNT OF ACREAGE THAT THE CONTRACTOR CAN ADEQUATELY PROTECT PRIOR TO A PREDICTED RAIN EVENT. FOR LARGER SITES, GRADING SHOULD BE PHASED. IT MAY BE NECESSARY TO DEPLOY EROSION AND SEDIMENT CONTROL BMPs IN AREAS THAT ARE NOT COMPLETED, BUT ARE NOT ACTIVELY BEING WORKED BEFORE ADDITIONAL GRADING IS COMPLETED. 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT: JOHN NORUM 2. DEVICES SHOWN ON CITY APPROVED PLANS SHALL NOT BE MOVED OR MODIFIED 3. ALL EROSION CONTROL DEVICES SHALL BE RESTORED TO WORKING ORDER TO THE 4. ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED DUE TO INCOMPLETE GRADING OR UNFORSEEN CIRCUMSTANCES. THROUGHOUT THE DURATION OF THE CONSTRUCTION WORK (YEAR ROUND). FROM TYLER STREET DEV LLC AT (PHONE NO.) (949) 678-4927. WITHOUT THE APPROVAL OF THE CITY INSPECTOR. SATISFACTION OF THE CITY ENGINEER AFTER EACH RAIN EVENT. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREATE A HAZARDOUS CONDITION. 6. GRADING AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY. 7. ALL BMP PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY AND WHEN THREE (3) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAIN EVENT. 8. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM AGGREGATE. BMPs AS DESCRIBED IN THE STORM WATER POLLUTION PREVENTION PLAN. THIS INCLUDES TO PROVIDE SUFFICIENT PROTECTION FROM RUNOFF DURING RAIN EVENTS. THE ABILITY TO INSTALL BMP MATERIALS IN A PROMPT MANNER IS NOT SUFFICIENT. BMPs NEED TO BE INSTALLED IN THESE AREAS. MUST BE INSPECTED AND/OR SERVICED PRIOR TO OCTOBER 1 OF EACH YEAR. VERIFICATION OF THESE INSPECTIONS WILL BE PROVIDED TO THE CITY UPON REQUEST. ALL BUILDING PADS, UNFINISHED ROADS, AND SLOPES. THE ABILITY TO INSTALL BMPs IN A PROMPT MANNER IS NOT SUFFICIENT; BMPs MUST BE INSTALLED FOR THESE AREAS. ARE REQUIRED TO BE INSTALLED ACCORDING TO THE SWPPP OR EROSION CONTROL PLAN: SILT FENCE 25% ROCK BAGS 125% FIBER ROLLS 50% TRACKING CONTROL 25% OTHER BMPs DETERMINED AS NEEDED STOP WORK IS NECESSARY. COMMENCING CONSTRUCTION BETWEEN AUGUST 1 AND OCTOBER 1 OF EACH YEAR. TRAINING RECORDS MUST BE RETAINED WITHIN THE SWPPP AND AVAILABLE UPON REQUEST. HEREIN SHALL BE TREATED WITH ONE OF THE FOLLOWING PLANTING STANDARDS: COVER CROP SHALL BE A SEED MIX TYPICALLY MADE UP OF QUICK GERMINATING AND FAST COVERING GRASSES, CLOVERS, AND/OR WILDFLOWERS. SUBMIT THE SPECIFIC SEED MIX FOR CITY APPROVAL PRIOR TO APPLICATION. THE COVER CROP SHALL BE APPLIED AT A RATE SUFFICIENT TO PROVIDE 90% COVERAGE WITHIN THIRTY (30) DAYS. THE TYPE OF EROSION CONTROL MATTING SHALL BE AS APPROVED BY THE CITY AND AFFIXED TO THE SLOPE AS RECOMMENDED BY THE MANUFACTURER. ON SLOPES 3 FEET OR LESS IN VERTICAL HEIGHT WHERE ADJACENT TO PUBLIC WALKS OR STREETS: WHEN PLANTING OCCURS BETWEEN AUGUST 15 AND APRIL 15, EROSION CONTROL MATTING SHALL BE REQUIRED. DURING THE REMAINDER OF THE YEAR, THE COVER CROP AND/OR EROSION CONTROL MATTING MAY BE USED. ON SLOPES GREATER THAN 3 FEET IN HEIGHT, EROSION CONTROL MATTING SHALL BE REQUIRED AND A COVER CROP SHALL NOT BE USED, UNLESS OTHERWISE APPROVED BY THE CITY. b. STANDARD 2 - GROUND COVER ONE HUNDRED (100%) PERCENT OF THE AREA SHALL BE PLANTED WITH A GROUND COVER KNOWN TO HAVE EXCELLENT SOIL BINDING CHARACTERISTICS (PLANTED FROM A MINIMUM SIZE OF FLATTED MATERIAL AND SPACED TO PROVIDE FULL COVERAGE WITHIN ONE YEAR). c. STANDARD 3 - LOW SHRUBS LOW SPREADING WOODY SHRUBS (PLANTED FROM A MINIMUM OF 1-GALLON CONTAINERS) SHALL COVER A MINIMUM OF SEVENTY (70%) PERCENT OF THE SLOPE FACE (AT MATURE SIZE). d. STANDARD 4 - TREES AND/OR LARGE SHRUBS TREES AND/OR LARGE SHRUBS SHALL BE (PLANTED FROM A MINIMUM OF 1-GALLON CONTAINERS) INSTALLED AT A MINIMUM RATE OF ONE (1) PLANT PER TWO HUNDRED (200) SQUARE FEET. B. SLOPES 6:1 OR STEEPER AND: a. 3' OR LESS IN VERTICAL HEIGHT AND ADJACENT TO PUBLIC WALKS OR STREET REQUIRE AT A MINIMUM STANDARD 1 (COVER CROP OR EROSION CONTROL MATTING). b. 3' TO 8' IN VERTICAL HEIGHT REQUIRE STANDARD 1 (EROSION CONTROL MATTING SHALL BE INSTALLED IN LIEU OF A COVER CROP, 2 AND 3. c. IN EXCESS OF 8' IN VERTICAL HEIGHT REQUIRE STANDARD 1 (EROSION CONTROL MATTING SHALL BE INSTALLED IN LIEU OF A COVER CROP, 2, 3, AND 4. d. REQUIRING PLANTING SHALL BE IRRATED WITH A PERMANENT, AUTOMATICALLY CONTROLLED, IRRIGATION SYSTEM COVERING 100% OF THE PLANTED AREA IN CONFORMANCE WITH THE CITY'S SLOPE IRRIGATION STANDARDS. C. AREAS GRADED FLATTER THAN 6:1 REQUIRE A COVER CROP PER STANDARD 1 WITH ONE OF MORE OF THE FOLLOWING CONDITIONS: a. SHEET GRADED PADS NOT SCHEDULED FOR IMPROVEMENTS WITHIN 6 MONTHS OF COMPLETION OF ROUGH GRADING. b. A POTENTIAL EROSION PROBLEM AS DETERMINED BY THE CITY. c. IDENTIFIED BY THE CITY AS HIGHLY VISIBLE AREAS TO THE PUBLIC OR HAVE SPECIAL CONDITIONS THAT WARRANT IMMEDIATE TREATMENT. AND MAINTAINED. NF NF TIER 2 CITY STORM WATER STORM WATER POLLUTION PREVENTION NOTES GENERAL SITE MANAGEMENT REQUIREMENTS EROSION CONTROL HYDROSEEDING. PLANTING AND IRRIGATION POLLUTION PREVENTION PLAN (TIER 2 SWPPP) OWNER/APPLICANT: EMERGENCY CONTACT: / VICINITY MAP CONSTRUCTION THREAT: □ C: C: C: .2 --"" .2 .2 -iii "" iii --0, 0 "" C: "' § <.> <.> C: :s ·E E C: E C: .2 -2 .s .2 .9-0 0 0 E -"' -::;; "" "' 0, -~ ~ --.!,; ;5. ::, c 0, ~ 0 §~ .s "' "' "' ~ .z-0 C: o-0, g.. "' .s § "' J G ~ .2 "' 0, ~ .!,; a:, g. a; " § C: 0, "' ., "' ~ 0 .s u~ -·.; "' --.s ~ .!,; E "' "" "' ~ "" "' ::;; C: " C: ➔ -2 ~ "" "' " VJ "' i 0, "' 0, a:, 0 C: C: C: c:, ::, ~ -"' -" "' ~CJJ ~ <.> -0 0 ~-£ ... 0 ]~ "" 0 "' C: C: 0 "' i~ ~ 0, "" c:, a:, 0, "s 0.2 " " -::;; c:, 0, C: C: _E Cl:.:; c., "' ~ 0, 0 " -~ "" ... -:n .S;; "' " :S -~ ~ "' 0 E al ·" "' ~~ <.> 0,-~-£ ·-0, .l2-CL e 0, 0 "' ~ ti 1 "' ::, .g ~~ i._:.:; .s::: e ..Q ~ e "" " ... ·-"" .$2 6 "" 0 "' -"R -g.. " " ::, ... --g ... -g 0 " 0 0 0 ~c: CJJ .!Q 0 0 ... 0 -., 0 ... <.> ~ 0 0 ~o ~i -.c: " ~o -0 :.::: § ct~ " ~ ~e's Vi 55 <Jl 6 ~ G ti~ Cf) ct -0, -o ~ ct 0 ~ ts ~en ~ -bt8 c5l ::;; ::t: <.o VJ .s VJ a:: CLO CL VJ ➔ "' .... " "' 0, -.,., " 0 "' -.,., " co -"' .,., .... "' --.... "' <o co --I I I I I I I I I I I I I I I I J, J, J, I I I I I I G:l G:l c., G:l G:l G:l bj bj bj bj bj bj bj bj ~ ~ ~ i i i i i kl '2: '2: '2: vi Gradina/Soil Disturbance ✓ ✓ ✓ ✓ ✓ .., Trenchina/txcavation ✓ Stockpilinq Drillinn IBorina J Concrete/Asphalt Sawcuttinq ✓ ✓ .., Concrete Flatwork ✓ ✓ ✓ ✓ ./ vi Paving ✓ ✓ ✓ ✓ .., Conduit/Pipe Installation ✓ ✓ j Stucco/Mortar Work .., Waste Disposal ✓ ✓ ✓ ✓ ✓ j Staainn ILav Down Area ./ ✓ ✓ [auioment Maintenance and Fuelina j Hazardous Substance Use/Storaae ,./ ✓ ✓ Dewaterina Site Access Across Dirt Other (list): Instructions: 1. Check the box to the left of all applicable construction activity (first column) expected to occur during construction. 2. Located along the top of the BMP Table is a list of BMP's with it's corresponding California Stormwater Quality Association (CASQA) designation number. or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column. Choose one J. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project. "' -"' i .\! "' --"' " g. i--"' VJ-o-C: '"' iii '-.. iii "' "' " E " E ~ ~ .g "' -" 1:' 0, 0 0, ... 0, oO <.> 0 :!;:O N C: C: C: C: § ~~ 8~ c5l ::;; <o co 0, I I I i i i ✓ ./ ✓ ./ ✓ ✓ ,/ ✓ ./ ,/ t-----+--+---------------,t----+---+-----+----1 ~ 11 CITY OF CARLSBAD I LJ GRADING PLANS FOR: APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63912 EXPIRES 9 30 26 DAlE DA 1E INITIAL ENGINEER OF WORK REVISION DESCRIPTION DA 1E INITIAL DAlE INITIAL OlHER APPROVAL CITY APf'ftOVAL DWN BY: CHKD BY: __ _ RVWD BY: PROJECT NO. DRAWING NO. Docusign Envelope ID: D48B54F8-556D-45B8-ABE2-69EB8EFFFC77 5/14/2025 4 5 45 SH E D AU T O C A R E SH O P ST O R A G E BU I L D I N G SHIPPING CONTAINER XX X X X X X X X X X X X S S S S S S S S S S S S S S S S S S S S S G G G G G G G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W IRR IRR IRR IRR W W W W S S S F F F F SD SD W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W C JT JT JT JT JT JT JT JT JT SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD S D SD SD SD SD SD SD WM WM JT JT JT JT J T JTJTJTJTJTJTJTJT JT JT OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE W WW W SD SD SD SD SD SD JT X X X X XXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXX X X X XX XX XXX XXX X X X XX XX X SD-B N3 4 ° 0 0 ' 4 8 " W 1 3 9 . 9 0 ' LOT 6 MAP NO. 1743 APN: 204-070-28-00 LOT 4 MAP NO. 1743 APN: 204-010-08-00 FU T U R E D E V E L O P M E N T AP N : 2 0 4 - 0 1 0 - 1 0 - 0 0 TY L E R S T R E E T PINE AVENUE SD-B SD-BSD-B SD-BSD-B SD-BSD-B UNIT 12 FF = 46.4 PAD = 45.7 UNIT 6 FF = 46.4 PAD = 45.7 UNIT 5 FF = 46.4 PAD = 45.7 UNIT 9 FF = 47.1 PAD = 46.4 UNIT 8 FF = 47.1 PAD = 46.4 UNIT 11 FF = 46.4 PAD = 45.7 UNIT 10 FF = 46.4 PAD = 45.7 UNIT 7 FF = 47.1 PAD = 46.4 UNIT 4 FF = 46.4 PAD = 45.7 UNIT 3 FF = 47.1 PAD = 46.4 UNIT 2 FF = 47.1 PAD = 46.4 UNIT 1 FF = 47.1 PAD = 46.4 SD-K SD-K SD-K SD-K 5.0' PUBLIC R/W DEDICATION 15.0'5.0' SD-F SD-F SD-F S3 4 ° 0 0 ' 4 8 " E 6 0 5 . 4 9 ' N56°00'45"E 605.49' N3 4 ° 0 0 ' 4 8 " W 6 0 5 . 4 9 ' S56°00'01"W 605.49' (S E E D W G 5 4 9 - 9 F O R P U B L I C IM P R O V E M E N T S I N R O W ) SE-4SE-4 SE-4 SE-4 SE-10 SE-10 SE-10 SE-10 SE-10 SE-10 SE-10 SE-1 SE-1 SE-1 SE-1 GRAPHIC SCALE: 1" = 10' 0 10 20 30 PLAN VIEW - EROSION CONTROL PLAN SCALE: 1" = 10' HORIZONTAL DETAIL B: GRAVEL BAGS NOT TO SCALE DETAIL A: CONSTRUCTION ENTRANCE NOT TO SCALE DETAIL C: SILT FENCE NOT TO SCALE PROVIDE APPROPRIATE TRANSITION BETWEEN STABILIZED CONSTRUCTION ENTRANCE AND PUBLIC RIGHT-OF- WAY *LESSER DISTANCE ALLOWED WITH CITY INSPECTOR APPROVAL 50'MIN.* PLAN DRIVE AISLE EXISTING GROUND 3" TO 6" COARSE AGGREGATE 50'MIN.* 12" MIN. PROFILE 16'MIN. GRADE 6% TO 8% 4% TO 6% 2% TO 4% 25' 40' 50' 100'LESS THAN 2% INTERVAL GRAVEL BAG ROW SPACING TABLE AREA DRAIN TWO LAYERS OF GRAVEL BAGS WITH ENDS OVERLAPPED ACTS AS SPILLWAY GAP BETWEEN BAGS RUNOFF WIRE FILTER FABRIC 4 IN (10 CM) EXCAVATED SOIL. 4. BACKFILL AND COMPACT THE INTO THE TRENCH. THE WIRE FENCE AND EXTEND IT 3. ATTACH THE FILTER FABRIC TO THE POSTS. 2. STAPLE WIRE FENCING TO ALONG THE LINE OF POSTS. TRENCH UPSLOPE FROM AND 4 BY 4 IN (10 BY 10 CM) 1. SET POSTS AND EXCAVATE A LOW IMPACT DEVELOPMENT COMPONENTS SD-B DIRECT RUNOFF TO PERVIOUS AREAS SD-K SUBSTAINABLE LANDSCAPING SD-F SIGNAGE TO DISCOURAGE DUMPING SE-1, SILT FENCE; DETAIL C SE-4 GRAVEL BAG CHECK DAM; DETAIL B SE-10, STORM DRAIN INLET PROTECTION; DETAIL B TR-1, STABILIZED CONSTRUCTION ENTRANCE; DETAIL A STREET SWEEPING AND VACUUMING PER SE-7 SCHEDULING PER EC-1 MATERIAL DELIVERY AND STORAGE PER WM-1 MATERIAL USE MANAGEMENT PER WM-2 STOCKPILE MANAGEMENT PER WM-3 SPILL PREVENTION AND CONTROL PER WM-4 SOLID WASTE MANAGEMENT PER WM-5 HAZARDOUS WASTE MANAGEMENT PER WM-6 CONCRETE WASTE MANAGEMENT PER WM-8 SANITARY / SEPTIC WASTE MANAGEMENT PER WM-9 PAVING AND GRINDING OPERATIONS PER NS-3 VEHICLE AND EQUIPMENT CLEANING PER NS-8 WIND EROSION PER WE-1 QUANTITYLEGEND 60 LF / 120 EA 600 LF 1 EA REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. TYLER STREET HOMES CT 2024-0001 549-9A GR 2024-0023 PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4070 9 J:\ACTIVE JOBS\4070 NORUM-CARLSBAD-Tyler Street\CIVIL\DRAWING\GRADING PLANS TIER 2 SWPPP 8 100 EA NF NF 4 I I I I \ \ ' ' ' \ \ I I =-::t=__ I I I I -,-,-= JI r----~ -' I ~ ,.. • I f:]/:m'==-~~r"7'1'.} '-. ' '-I •• • I :• ' I ·-, I .\ ;/ I LUU< ' ·-.. -, I I I 1-----='"-- I I I ~ I I 11 I I / / / I I I \ \ I I ' I ' r' ' ' ., I I -' I I I ' -I \ ' -, \ i., .I -------........ -------\ /I" / I " • • -I t l!cc::::;::J!.:::,,:-;pl'~ ......... ~~~~ ............... 'r""' ......... ~-v-.:~ .......... ~....,..,11-,,<-i~~~===:!~~~,......~ I I _---j_---=----_,----= = I = = -----cL-----=-_t-_ =r \ I -, \. • _---j_---=---- I I I I I I I I J ---=r- " I / "-v / / I " " I / "V / IF-. : • • • • • • / / / / / I -- • ♦•♦ •••• + + + + :♦:♦ ♦:♦: + + + + / / / Wt. lllll:~I LWM J~~L SCH PG VEC El MU~ CSM SWM@ I - ' I , I I I ,. ~ i / I " I C, C, ~ - _,,, _,,, _,,, _,,, _,,, _,,, _,,, _,,, I I I I I I I ~/ I I I l __ ~ f------t+---;.-: ---- \ I D D D D D . I ]r-,1 _L l CJ I ----------- \ I \ I \ I \ \ I \ I ',1 El E l I I I I I I I I I I I I I I -I I CWM I I PG YEC I WE ~--~ I ------ , t-----+--+-----------------,t-----+---+----+------t ~ 11 CITY OF CARLSBAD I LJ 1----+---+-----------------,1---+---+----+----1 GRADING PLANS FOR: ,__--+---+-----------------,,__-+---+----+----< APPROVED: JASON S. GELDERT t----+---+-----------------,t---+---+----+----1 :::;;EN;:;:;Gl:;::NEE:;;;Rl::';::N:::::G::::MAN::::::::::AGER=:';::::::::R:::CE::::::6::::39:::::12:::::::::::EXP::::::::::IRES=:::::9=:::::;'30~26:::::::::::::D:::::AlE=::: 1----=D~A1E=-+~,N=111.,.,..+•·-------------+----+---+------I-----I DWN BY: --PROJECT NO. I DRAWING NO. ~ t--DA_1E~_INl_11AL--+_D_A1E~_IN_l11_AL--t CHKD BY: __ ENGINEER OF WORK REVISION DESCRIPTION OlHER APPROVAL CITY APf'ftOVAL RVWD BY: Docusign Envelope ID: D48B54F8-556D-45B8-ABE2-69EB8EFFFC77 5/14/2025 4 5 45 X XXX X X X X X X X X X X X X X X X XXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXX X X X XX XX XXX XXX X X X XX XX X S S S S S S S S S S S S S S S S S S S S S S G G G G G G G G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W SD SD W W W W W W W W W W W W W W SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE W W SD SD SD SD SD SD N56°00'01"E 162.86' N3 4 ° 0 0 ' 4 8 " W 1 3 9 . 9 0 ' N56°00'45"E 162.86' N3 4 ° 0 0 ' 4 8 " W 1 3 9 . 8 7 ' TY L E R S T R E E T PINE AVENUE BL O C K 3 1 MA P N O . 7 7 5 AP N : 2 0 4 - 0 8 1 - 0 1 - 0 4 LOT 6 MAP 1743 APN: 204-070-28-00 LOT 4 MAP 1743 APN: 204-010-08-00 LOT 5 MAP 775 APN: 204-010-10-00 UNIT 8 FF = 47.1 PAD = 46.4 UNIT 2 FF = 47.1 PAD = 46.4 UNIT 11 FF = 46.4 PAD = 45.7 UNIT 5 FF = 46.4 PAD = 45.7 UNIT 7 FF = 47.1 PAD = 46.4 UNIT 1 FF = 47.1 PAD = 46.4 UNIT 9 FF = 47.1 PAD = 46.4 UNIT 3 FF = 47.1 PAD = 46.4 UNIT 10 FF = 46.4 PAD = 45.7 UNIT 4 FF = 46.4 PAD = 45.7 UNIT 12 FF = 46.4 PAD = 45.7 UNIT 6 FF = 46.4 PAD = 45.7 LA LA LA LA 1 2 3 4 5 6 7 8 1615 1411 10 9 12 13 17 18 19 20 22 21 23 24 2625 27 28 29 31 30 32 33 34 38 39 35 43 42 41 4746 37 36 44 45 40 J:\ACTIVE JOBS\4070 NORUM-CARLSBAD-Tyler Street\CIVIL\DRAWING\GRADING PLANS 1 LA 462 LANDSCAPING SUSTAINABLE DWG 549-9A SHEET 3 SITE DESIGN ANNUALLY & AS-NEEDEDSF.TC-32 SEMI-ANNUALLYRAISED PLANTER BIOFILTRATION TREATMENT CONTROL QUANTITY FREQUENCY INSPECTION BMP TABLE FREQUENCY MAINTENANCESHEET NO.(S)DRAWING NO.CASQA NO.SYMBOLBMP ID #BMP TYPE PROPERTY BOUNDARY CENTERLINE OF ROAD ADJACENT PROPERTY LINE PUBLIC RIGHT-OF-WAY ROOF DOWNSPOUT OUTFALL LOCATION LEGEND 2,877 SF. TO PERVIOUS DIRECT RUNOFF AREAS 16- 21 24- 25 28- SD-K SD-B AS-NEEDEDANNUALLY MONTHLYANNUALLY TRASH CAPTURE BMPS PLAN VIEW - SINGLE SHEET BMP PLAN NOT TO SCALE PAVERS PERVIOUS 6,913 SF.SEMI-ANNUALLYANNUALLYTC-10 (858) 259-8212 SAN DIEGO, CA 92110 1911 SAN DIEGO AVENUNE PLSA ENGINEERING BRYAN A. KNAPP THE EOW WILL VERIFY THAT PERMANENT BMPS ARE CONSTRUCTED AND OPERATING IN COMPLIANCE WITH THE APPLICABLE REQUIREMENTS. PRIOR TO OCCUPANCY THE EOW MUST PROVIDE: 1. PHOTOGRAPHS OF THE INSTALLATION OF PERMANENT BMPS PRIOR TO CONSTRUCTION, DURING CONSTRUCTION, AND AT FINAL INSTALLATION. 2. A WET STAMPED LETTER VERIFYING THAT PERMANENT BMPS ARE CONSTRUCTED AND OPERATING PER THE REQUIREMENTS OF THE APPROVED PLANS. 3. PHOTOGRAPHS TO VERIFY THAT PERMANENT WATER QUALITY TREATMENT SIGNAGE HAS BEEN INSTALLED. PRIOR TO RELEASE OF SECURITIES, THE DEVELOPER IS RESPONSIBLE FOR ENSURING THE PERMANENT BMPS HAVE NOT BEEN REMOVED OR MODIFIED BY THE NEW HOMEOWNER OR HOA WITHOUT THE APPROVAL OF THE CITY ENGINEER. BMP CONSTRUCTION AND INSPECTION NOTES: SIGNATURE 6. SEE PROJECT SWQMP FOR ADDITIONAL INFORMATION. 5. REFER TO MAINTENANCE AGREEMENT DOCUMENT. COMPANY CERTIFICATION PHONE NO. ADDRESS NAME PLAN PREPARED BY: CONTACT PHONE NO. ADDRESS NAME PARTY RESPONSIBLE FOR MAINTENANCE: BMP NOTES: AND INSTALLATION. HAS INSPECTED THIS PROJECT FOR APPROPRIATE BMP CONSTRUCTION 4. NO OCCUPANCY WILL BE GRANTED UNTIL THE CITY INSPECTION STAFF WITHOUT PRIOR APPROVAL FROM THE CITY ENGINEER. 3. NO SUBSTITUTIONS TO THE MATERIAL OR TYPES OR PLANTING TYPES APPROVAL FROM THE CITY ENGINEER. 2. NO CHANGES TO THE PROPOSED BMPS ON THIS SHEET WITHOUT PRIOR RECOMMENDATIONS AND/OR THESE PLANS. 1. THESE BMPS ARE MANDATORY TO BE INSTALLED PER MANUFACTURER'S TDAM12(5)-PERF-FTC REM TRITON TC-40 3 EA ANNUALLY & AS-NEEDEDSEMI-ANNUALLY2931- 17 20- REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. TYLER STREET HOMES CT 2024-0001 549-9A GR 2024-0023 PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4070 9 GRAPHIC SCALE: 1" = 10' 0 10'20'30'SINGLE SHEET BMP SITE PLAN 9 JOHN NORUM FOR: TYLER STREET DEV LLC 2888 LOKER AVENUE EAST SUITE 220 CARLSBAD, CA 92008 (949) 678-4927 DWG 549-9A SHEET 3 DWG 549-9A SHEET 3 DWG 549-9A SHEET 3 DWG 549-9A SHEET 3 SOURCE CONTROL BMP SIGN SEE DETAIL THIS SHEET 16 EA3247-DWG 549-9A SHEET 8 CB INSERT NF NF ' ' ' ' ' .. , ___ _ ' • -. /---[1 I / I / / ) -/ ---/ / --/ ---/ / --/ / --./ / --_7'1 ; / / / , ' ' . . . . . . ' ' / / / / / ' / / I ✓ I • / / Ir;::::::::::: I ' / / -/ / / , I <I ) I "' I) I ' 7 ~ I I I I I I I I I I I I I I I I -------- f-----t+--~/--~-- -\ I 1 I \ I \ I \ I \ I \ I \ I \ I ,, 1 ' I I I I I I I I 'cr-{t\ -1r > > , > I f f-----c l I I I 00 00 00 00 00 00 □ • PERMANENT WATER QUALITY TREATMENT FACILITY KEEPING OUR WATERWAYS CLEAN MAINTAIN WITH CARE -NO MOD/FICA TIONS WITHOUT AGENCY APPROVAL WATER QUALITY SIGN -TYPICAL DETAIL PL S A i1m-~ PLSAENGINEERING.COM SCALE: NOT TO SCALE t-----+--+---------------,t----+---+-----+----1 ~ 11 CITY OF CARLSBAD I LJ t-----t--+----------------t-----+--+----t----1 GRADING PLANS FOR: DA 1E INITIAL DA 1E INITIAL DAlE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OlHER APPROVAL CITY APPROVAL APPROVED: JASON S. GELDERT ENGINEERING MANAGER DWN BY: ---1 CHKD BY: __ RVWD BY: _ RCE 63912 EXPIRES 9/30/26 DAlE PROJECT NO. I DRAWING NO. Docusign Envelope ID: D48B54F8-556D-45B8-ABE2-69EB8EFFFC77 5/14/2025