HomeMy WebLinkAbout2256 IVORY PL; ; CBR2024-1038; PermitPrint Date: 05/27/2025
Building Permit Finaled
Residential Permit
CBR2024-1038Permit No:
Job Address:
Permit Type:
Parcel #:
Valuation:
Occupancy Group:
2256 IVORY PL, CARLSBAD, CA 92009-1732
BLDG-Residential
2132021800
$12,000.00
Work Class:
Lot #:
Project #:
Solar/Photovoltaic
Status:
Applied:
Issued:
04/26/2024
06/14/2024
Finaled Close Out:05/27/2025
#of Dwelling Units:
Track #:
Plan #:
Closed - Finaled
Plan Check #:
Orig. Plan Check #:Bathrooms:
Final Inspection:07/02/2024Bedrooms:Construction Type:
Occupant Load:
Code Edition:
Sprinkled:
INSPECTOR:Alvarado, Tony
NEW 11.85DC KW(10.8AC KW) ROOF MOUNTED PHOTOVOLTAIC SYSTEM W/ 30 MODS, 30 MICRO INV, 3 BATTERIES. DAISY
CHAINED BATTERIES DISQUALIFY THIS FROM SOLARAPP. (E-REVIEW)
Description:
Project Title:
Applicant:
JOHN LAVENDER
10769 WOODSIDE AVESANTEE, CA 92071-3174
AMOUNTFEE
BUILDING PLAN CHECK $336.05
SB1473 – GREEN BUILDING STATE STANDARDS FEE $1.00
SOLAR–RESIDENTIAL: BATTERY BACK-UP $210.00 SOLAR–RESIDENTIAL: per kW $307.00
STRONG MOTION – RESIDENTIAL (SMIP)$1.56
Total Fees:$855.61 Total Payments To Date:$855.61 Balance Due:$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad CA 92008-7314 ï 442-339-2719 ï 760-602-8560 f ï www.carlsbadca.gov
Building Division Page 1 of 1
{"Cityof
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
Plan Check
Est. Value
PC Deposit
Date
Job Address Unit: APN:
CT/Project #: Lot #: Year Built:
BRIEF DESCRIPTION OF WORK:
PROPERTY OWNER
Name:
Address:
State: Zip: City: State: Zip:
Phone:
APPLICANT (PRIMARY CONTACT)
Name:
Address:
City:
Phone:
Email: Email:
DESIGN PROFESSIONAL CONTRACTOR OF RECORD
Name: Business Name:
Address:
City: State: Zip:
Phone:
Email:
Architect State License:
Address:
City: State: Zip:
Phone:
Email:
CSLB License #: Class:
Carlsbad Business License # (Required):
APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information of the plans is accurate. I
agree to comply with all City ordinances and State laws relating to building construction.
NAME (PRINT): DATE:
1635 Faraday Ave Carlsbad, CA 92008
SIGN:
Ph: 442-339-2719 Email: Building@carlsbadca.gov
1 REV. 04/22
New SF : Living SF, _ Deck SF, Patio SF, Garage SF
Is this to create an Accessory Dwelling Unit? Y N New Fireplace? Y N , if yes how many? _________
Solar: KW, Modules, Mounted: Roof Ground, Tilt: Y N, RMA: Y N,
Battery: Y N, Panel Upgrade: Y N
Other:
Additional Gas or Electrical Features? Pool/Spa: SF
Is the area a conversion or change of use? Y N Remodel: SF of affected area
ůĞĐƚƌŝĐDĞƚĞƌŶƵŵďĞƌ͗ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ
8082864939 760 749 1111
LINDSAY@DESIGNS.SOLAR LINDSAY@DESIGNS.SOLAR
COSMIC SOLAR
943 POINSETTIA AVE, STE 401 VISTA, CA 92081
760 749 1111
LINDSAY@DESIGNS.SOLAR
831831 - B, C-10
12/21/2022LINDSAY GRIMSHAWLINDSAY GRIMSHAW
2256 IVORY PLACE CARLSBAD, CA 92009
NEW 11.85KW ROOF MOUNT PV SYS W/ 30 MODS, 30 MICRO INV, 3 BATTERIES.
LINDSAY GRIMSHAW
10769 WOODSIDE AVE SANTEE CA 92071
SAGHBINI, ALAA
2256 IVORY PLACE CARLSBAD, CA 92009
2132021800
□
□
D
□
C Cityof
Carlsbad
CG O 0
0 0
0 0
00
0 0
00 00
THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER:__________________
A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING
THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE.
(OPTION A): LICENSED CONTRACTOR DECLARATION:
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the
following declarations (CHOOSE ONE):
I have and will maintain a certificate of consent to self-insure for workers’ compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued. Policy No.
-OR-
I have and will maintain worker’s compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers’ compensation insurance carrier and policy number are: Insurance Company Name:
Policy No. _____________________________________________________________ Expiration Date:
-OR-
Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become
subject to the workers’ compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
interest and attorney’s fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender’s Name: Lender’s Address:
CONTRACTOR CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and
utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are
not approved for construction and may be required to be altered or removed. The city’s approval of the application is based on the premise that the submitted documents and plans show
the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed
use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation.
All improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted.
NAME (PRINT): SIGNATURE: DATE:
Note: If the person signing above is an authorized agent for the contractor provide a letter of authorization on contractor letterhead.
(OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor’s License Law for the following reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor’s License Law does not apply to an owner of property who builds or improves thereon, and who does such
work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
-OR-
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor’s License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor’s License Law).
-OR-
I am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
AND,
FORM B-61 “Owner Builder Acknowledgement and Verification Form” is required for any permit issued to a property owner.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed
contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is
submitted or at the following Web site: http://www.leginfo.ca.gov/calaw.html.
OWNER CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility
easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved
for construction and may be required to be altered or removed. The city’s approval of the application is based on the premise that the submitted documents and plans show the correct
dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each
building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All
improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted.
NAME (PRINT): SIGN: DATE:
Note: If the person signing above is an authorized agent for the property owner include form B-62 signed by property owner.
1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov
2
REV. 04/22
-OR -
STATE
9047550 3/1/2023
LINDSAY GRIMSHAW LINDSAY GRIMSHAW 12/21/22
□
□
□
□
□
□
□
Building Permit Inspection History Finaled
PERMIT INSPECTION HISTORY for (CBR2024-1038)
BLDG-Residential 04/26/2024Application Date:Permit Type:Owner:
Solar/Photovoltaic 06/14/2024Work Class:Issue Date:Subdivision:CARLSBAD TCT#02-20 LA COSTA
GREENS NEIGHBORHOOD 1.10
12/30/2024Expiration Date:Status:
IVR Number: 56086
Closed - Finaled 2256 IVORY PL
CARLSBAD, CA 92009-1732
Address:
Scheduled
Date
Inspection Type Inspection No. Inspection
Status
Primary Inspector Reinspection InspectionActual
Start Date
07/02/2024 07/02/2024 BLDG-35 Solar Panel 253441-2024 Passed Tony Alvarado Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency Yes
BLDG-Final Inspection 253847-2024 Passed Tony Alvarado Complete
COMMENTS PassedChecklist Item
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
Tuesday, May 27, 2025 Page 1 of 1
{cityof
Carlsbad
RESIDENTIAL SOLAR
(Property Owner Consent Form)
B-13A
Community Development
Building Division
1635 Faraday Avenue
442-339-2719 or via email
at Building@CarlsbadCA.gov
Form B-13A; August 2022 Page 1 of 1
I hereby authorize the following company/person(s) to act as my agent(s) to apply for, sign, and file the
documents necessary to obtain a building permit for the installation of a solar photovoltaic system at my
property.
AUTHORIZED AGENT
Company name:
Company address:
Representative name:
Phone number:
Email address:
PROJECT INFORMATION
Property address:
Project description:
I declare under penalty of perjury that I am the property owner for the address listed above and have
reviewed the above information and certify its accuracy.
Property owner (print) Property owner (signature) Date
The property owner’s original (wet) signature required. Agent/contractor is not authorized to sign on behalf of property owner.
SOLAR PERMIT SPECIALISTS
10769 WOODSIDE AVE SANTEE CA 92071
LINDSAY GRIMSHAW
8082864939
LINDSAY@DESIGNS.SOLAR
Alaa Saghbini (Apr 26, 2024 09:42 PDT)Alaa Saghbini 26/04/24
2256 IVORY PLACE
NEW 11.85KW ROOF MOUNT PV SYS W/ 30 MODS, 30 MICRO INV, 3 BATTERIES.
{city of
Carlsbad
True North Compliance Services, Inc.
3939 Atlantic Avenue Suite 224, Long Beach, CA 90807
T | 562.733.8030
Transmittal Letter
June 4, 2024
City of Carlsbad FIRST REVIEW
Community Development Department - Building Division City Permit No: CBR2024-1038
1635 Faraday Ave. True North No.: 24-018-398
Carlsbad, CA 92008
Plan Review: PV SYSTEM
Address: 2256 Ivory Pl, Carlsbad CA
Applicant Name: Lindsay Grimshaw Applicant Email: lindsay@designs.solar
True North Compliance Services, Inc. has completed the review of the following documents for the project
referenced above on behalf of the City of Carlsbad. Our comments can be found on the attached list.
1. Drawings: Electronic copy dated May 10, 2024, by Cosmic Solar.
Attn: Permit Technician, the scope of work on the plans has been reviewed for coordination with the scope of
work on the permit application. See below for information if the scope of work on plans differs from the permit
application:
Valuation: Confirmed
Scope of Work: Confirmed
Floor Area: N/A
Notes: N/A
Our comments follow on the attached list. Please call if you have any questions or if we can be of further
assistance.
Sincerely,
True North Compliance Services
Review By: Kevin Ybarra - Plans Examiner
True orth
'/. COMPLIANCE SERVICES
PV SYSTEM City of Carlsbad– FIRST REVIEW
2256 Ivory Pl City Permit No.: CBR2024-1038
June 4, 2024 True North No.: 24-018-398
Page 2
Plan Review Comments
ELECTRONIC - RESUBMITTAL INSTRUCTIONS:
Please do not resubmit plans until all departments have completed their reviews. For status, please
contact building@carlsbadca.gov
Please make all corrections, as requested in the correction list. Corrected sets can be submitted as follows:
Email the revised plans and comment response letter(s) to building@carlsbadca.gov for continued
review.
Note: If this project requires FIRE PREVENTION review, ensure that you follow their specific
instructions for resubmittal review. The city will not route plans back to Dennis Grubb &
Associates for continued Fire Prevention review.
GENERAL INFORMATION:
A. The following comments are referred to the 2022 California Building, Mechanical, Plumbing, Electrical
Codes, California Green Building Standards Code, and Energy Code (i.e., 2021 IBC, UMC, UPC, and 2020
NEC, as amended by the State of California).
B. There may be other comments generated by the Building Division and/or other City departments that will
also require your attention and response. This attached list of comments, then, is only a portion of the plan
review. Contact the City for other items.
C. Respond in writing to each comment by marking the attached comment list or creating a response letter.
Indicate which details, specification, or calculation shows the required information. Your complete and
clear responses will expedite the re-check.
D. Where applicable, be sure to include the architect and engineer’s stamp and signature on all sheets of the
drawings and on the coversheets of specifications and calculations per CBPC 5536.1 and CBPC 6735. This
item will be verified prior to plan approval.
OCCUPANCY & BUILDING SUMMARY:
Occupancy Groups: R3
Type of Construction: VB
Sprinklers: No
Stories: 2
Area of Work (sq. ft.): 657 sq. ft.
ELECTRICAL COMMENTS:
Sheet PV-4 Wire callout 6 shows dual #2awg feeds from the 200amp breaker to the Tesla Gateway. Per CEC
310.10(G)(1) min size of conductors used in parallel is 1/0 awg.
Sheet PV-4 Wire callout 5 shows #8awg ground from the Tesla Gateway to the backup sub panel. Per CEC
250.122, min size ground for 200amps is #6awg.
PV SYSTEM City of Carlsbad– FIRST REVIEW
2256 Ivory Pl City Permit No.: CBR2024-1038
June 4, 2024 True North No.: 24-018-398
Page 3
If you have any questions regarding the above comments, please contact Kevin Ybarra via telephone (562) 733-
8030.
[END]
True North Compliance Services, Inc.
3939 Atlantic Avenue Suite 224, Long Beach, CA 90807
T | 562.733.8030
Transmittal Letter
June 4, 2024
City of Carlsbad FIRST REVIEW
Community Development Department - Building Division City Permit No: CBR2024-1038
1635 Faraday Ave. True North No.: 24-018-398
Carlsbad, CA 92008
Plan Review: PV SYSTEM
Address: 2256 Ivory Pl, Carlsbad CA
Applicant Name: Lindsay Grimshaw Applicant Email: lindsay@designs.solar
True North Compliance Services, Inc. has completed the review of the following documents for the project
referenced above on behalf of the City of Carlsbad. Our comments can be found on the attached list.
1. Drawings: Electronic copy dated May 10, 2024, by Cosmic Solar.
Attn: Permit Technician, the scope of work on the plans has been reviewed for coordination with the scope of
work on the permit application. See below for information if the scope of work on plans differs from the permit
application:
Valuation: Confirmed
Scope of Work: Confirmed
Floor Area: N/A
Notes: N/A
Our comments follow on the attached list. Please call if you have any questions or if we can be of further
assistance.
Sincerely,
True North Compliance Services
Review By: Kevin Ybarra - Plans Examiner
True orth
'/. COMPLIANCE SERVICES
PV SYSTEM City of Carlsbad– FIRST REVIEW
2256 Ivory Pl City Permit No.: CBR2024-1038
June 4, 2024 True North No.: 24-018-398
Page 2
Plan Review Comments
ELECTRONIC - RESUBMITTAL INSTRUCTIONS:
Please do not resubmit plans until all departments have completed their reviews. For status, please
contact building@carlsbadca.gov
Please make all corrections, as requested in the correction list. Corrected sets can be submitted as follows:
Email the revised plans and comment response letter(s) to building@carlsbadca.gov for continued
review.
Note: If this project requires FIRE PREVENTION review, ensure that you follow their specific
instructions for resubmittal review. The city will not route plans back to Dennis Grubb &
Associates for continued Fire Prevention review.
GENERAL INFORMATION:
A. The following comments are referred to the 2022 California Building, Mechanical, Plumbing, Electrical
Codes, California Green Building Standards Code, and Energy Code (i.e., 2021 IBC, UMC, UPC, and 2020
NEC, as amended by the State of California).
B. There may be other comments generated by the Building Division and/or other City departments that will
also require your attention and response. This attached list of comments, then, is only a portion of the plan
review. Contact the City for other items.
C. Respond in writing to each comment by marking the attached comment list or creating a response letter.
Indicate which details, specification, or calculation shows the required information. Your complete and
clear responses will expedite the re-check.
D. Where applicable, be sure to include the architect and engineer’s stamp and signature on all sheets of the
drawings and on the coversheets of specifications and calculations per CBPC 5536.1 and CBPC 6735. This
item will be verified prior to plan approval.
OCCUPANCY & BUILDING SUMMARY:
Occupancy Groups: R3
Type of Construction: VB
Sprinklers: No
Stories: 2
Area of Work (sq. ft.): 657 sq. ft.
ELECTRICAL COMMENTS:
Sheet PV-4 Wire callout 6 shows dual #2awg feeds from the 200amp breaker to the Tesla Gateway. Per CEC
310.10(G)(1) min size of conductors used in parallel is 1/0 awg.
Sheet PV-4 Wire callout 5 shows #8awg ground from the Tesla Gateway to the backup sub panel. Per CEC
250.122, min size ground for 200amps is #6awg.
RESPONSE: UPdated wire size
RESPONSE: Updated wire size.
PV SYSTEM City of Carlsbad– FIRST REVIEW
2256 Ivory Pl City Permit No.: CBR2024-1038
June 4, 2024 True North No.: 24-018-398
Page 3
If you have any questions regarding the above comments, please contact Kevin Ybarra via telephone (562) 733-
8030.
[END]
True North Compliance Services, Inc.
8369 Vickers Street, Suite 207, San Diego, CA 92111
T | 562.733.8030
Transmittal Letter
May 8, 2024
City of Carlsbad FIRST REVIEW
Community Development Department - Building Division City Permit No: CBR2024-1038
1635 Faraday Ave. True North No.: 24-018-398
Carlsbad, CA 92008
Plan Review: Residential – PV System
Address: 2256 Ivory Pl., Carlsbad CA
Applicant Name: Lindsay Grimshaw Applicant Email: lindsay@designs.solar
True North Compliance Services, Inc. has completed the review of the following documents for the project
referenced above on behalf of the City of Carlsbad. Our comments can be found on the attached list.
1. Drawings: Electronic copy dated April 25, 2024, by Cosmic Solar.
Attn: Permit Technician, the scope of work on the plans has been reviewed for coordination with the scope of
work on the permit application. See below for information if the scope of work on plans differs from the permit
application:
Valuation: Confirmed
Scope of Work: Confirmed
Floor Area: Confirmed
Notes: N/A
Our comments follow on the attached list. Please call if you have any questions or if we can be of further
assistance.
Sincerely,
True North Compliance Services
Review By: Bryan Montes - Plan Review Engineer
True orth
'/. COMPLIANCE SERVICES
Residential – PV System City of Carlsbad– FIRST REVIEW
2256 Ivory Pl. City Permit No.: CBR2024-1038
May 8, 2024 True North No.: 24-018-398
Page 2
Plan Review Comments
Please do not resubmit plans until all departments have completed their reviews. For status, please
contact building@carlsbadca.gov
Please make all corrections, as requested in the correction list. Corrected sets can be submitted as follows:
Email the revised plans and comment response letter(s) to building@carlsbadca.gov for continued
review.
Note: If this project requires FIRE PREVENTION review, ensure that you follow their specific
instructions for resubmittal review. The city will not route plans back to Dennis Grubb &
Associates for continued Fire Prevention review.
GENERAL INFORMATION:
A. The following comments are referred to the 2022 California Building, Mechanical, Plumbing, Electrical
Codes, California Green Building Standards Code, and Energy Code (i.e., 2021 IBC, UMC, UPC, and 2020
NEC, as amended by the State of California).
B. There may be other comments generated by the Building Division and/or other City departments that will
also require your attention and response. This attached list of comments, then, is only a portion of the plan
review. Contact the City for other items.
C. Respond in writing to each comment by marking the attached comment list or creating a response letter.
Indicate which details, specification, or calculation shows the required information. Your complete and
clear responses will expedite the re-check.
D. Where applicable, be sure to include the architect and engineer’s stamp and signature on all sheets of the
drawings and on the coversheets of specifications and calculations per CBPC 5536.1 and CBPC 6735. This
item will be verified prior to plan approval.
OCCUPANCY & BUILDING SUMMARY:
Occupancy Groups: ??? (Provide this information)
Occupant Load: N/A
Type of Construction: ??? (Provide this information)
Sprinklers: ??? (Provide this information)
Stories: ??? (Provide this information)
Area of Work (sq. ft.): N/A
Residential – PV System City of Carlsbad– FIRST REVIEW
2256 Ivory Pl. City Permit No.: CBR2024-1038
May 8, 2024 True North No.: 24-018-398
Page 3
ARCHITECTURAL COMMENTS:
A1. On the cover sheet of the plans, provide the following project’s information:
a) List the dwelling’s occupancy group.
b) Specify the building’s occupancy group.
c) Indicate whether fire-sprinklers are installed throughout the building or not.
A2. Individual Energy Storage System (ESS) units shall have a maximum rating of 20 kWh and the aggregate
rating of the ESS units shall not exceed 8-0 kWh in attached garages, per CRC R328.5. Indicate the
individual and combined ratings of the proposed ESS units on the plans.
A3. Clarify location of the proposed ESS units. Garage?
A4. ESS units shall be separated from each other by not less than 3 feet except where smaller separation
distances are documented to be adequate based on large-scale fire testing complying with Section 1207.1.5
of the California Fire Code, per CRC R328.3.1. Provide spacing of ESS Units.
A5. The garage where the ESS units will be installed shall be protected by smoke alarms in accordance with
Section R314. A heat detector, listed and interconnected to the smoke alarm, shall be installed in locations
within dwelling units and attached garages, where smoke alarms cannot be installed based on listing. CRC
R328.7. Provide compliance.
A6. Provide the manufacturer spec sheets for the proposed ESS units on the plans.
If you have any questions regarding the above comments, please contact Bryan Montes via email
bryanm@tncservices.com or telephone (562) 733-8030.