HomeMy WebLinkAbout2856 WHIPTAIL LOOP; ; CBC2021-0453; PermitBuilding Permit Finaled •
{'Cityof
Carlsbad
Commercial Permit
Print Date: 04/09/2025
Job Address: 2856 WHIPTAIL LOOP, CARLSBAD, CA 92010-6708
Permit No:
Status:
(8(2021-0453
Closed -Finaled
Permit Type: BLDG-Commercial Work Class: Tenant Improvement
Parcel#: 2091201400 Track#:
Valuation: $332,466.00 Lot#:
Occupancy Group: B/M/Sl/Fl Project#:
#of Dwelling Units: Plan#:
Bedrooms:
Bathrooms:
Construction Type: IIIB
Orig. Plan Check#:
Occupant Load: 35 Plan Check #:
Code Edition: 2019
Sprinkled: Yes
Project Title:
Description: CAMSTON WRATH ER; OFFICE Tl (5,137 SF)/ PARTITIONS, HVAC, PLUMBING
Property Owner:
HAMANN OAK PROPERTIES LP
1000 PIONEER WAY
EL CAJON, CA 92020
(619) 440-7424
FEE
BUILDING PLAN CHECK
BUILDING PLAN REVIEW-MINOR PROJECTS (LDE)
BUILDING PLAN REVIEW -MINOR PROJECTS (PLN)
CERTIFICATE OF OCCUPANCY
COMM/IND Tl -STRUCTURAL
COMMUNITY FACILITIES DISTRICT (CFD) FEE -NON-RES
FIRE Plan Review (per hr -Regular Office Hours)
PUBLIC FACILITIES FEES -inside CFD
PUBLIC FACILITIES FEES -inside CFD
SB1473 -GREEN BUILDING STATE STANDARDS FEE
SEWER BENEF IT AREA FEES -E
SEWER CONNECTION FEE (General Capacity all areas)
STRONG MOTION -COMMERCIAL (SMIP)
TRAFFIC IMPACT Commercial-Industrial w/in CFD
Total Fees: $14,000.57 Total Payments To Date: $14,000.57
Applied: 11/23/2021
Issued: 01/18/2022
Finaled Close Out: 04/09/2025
Final Inspection: 11/23/2022
INSPECTOR: Kersch, Tim
Contractor:
HAMANN CONSTRUCTION
1000 PIONEER WAY
EL CAJON, CA 92020-1923
(619) 440-7424
Balance Due:
AMOUNT
$1,068.16
$194.00
$98.00
$15.00
$1,643.33
$260.94
$670.50
$6,050.88
$1,587.64
$14.00
$1,612.88
$424.15
$93.09
$268.00
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
{'cityof
Carlsbad
COMMERCIAL
BUILDING PERMIT
APPLICATION
B-2
Plan Check CBC. 2-o 2../ -f) '-/~
Est. Value I/ 3.#,A . '"/(,.IQ. tp# IJ. I
PC Deposit I .~L/,3 , ~3 f
Date II ·-<3 -Z.o Z.f
Job Address.......:Z;=~~!L...-!::~~::!.!:::li::::::!o~~~-----Suite: ____ APN: zoq -(ZO -ll/
Tenant Name #: ___ &,.......,m.......,5krt-......... __ W __ ~ _____________ Lot #: ____ Year Built: '2.0(q
Year Built: wq Occupancy: 1?,f \ 51 Construction Type:~ Fire sprinklersofEsO NO A/C:~ESQNo
BRIEF DESCRIPTION OF WORK:
D Addition/New: ___________ New SF and Use, _________ New SF and Use
______ SF Deck, SF Patio Cover, SF Other (Specify) ___ _
□Tenant Improvement: 6,1 ~=¼--, SF,
____ SF,
Existing Use: _0-"-+1-f"_l+r -=5_1 __ Proposed Use:-+-,~-----
Existing Use: Proposed Use: _____ _
0 Other: _________________________________ _
PRIMARY APPLICANT PROPERTY OWNER J
Name: i&-na:tiL. ,/i' c..vrJµ Name: Moor~ ~ , l-p
Address: ~ ~ ~ Address: ~ooo'r~ ~
City: _______ State: ___ .Zip:. ____ City: C'/ ~ State: ~ip:
Phone: Phone: <a tq-'-'40 -31:£-Zt/
Email: ____ ~ ...................... G?~--ham;.a..;..a._%.a..,_;,.._YlC-0""'-""-_, =(p81Yl....._..___ Email: ________________ _
DESIGN PROFESSIONAL CONTRACTOR OF RECORD
Name: __ PcuJL_...aa...~GJ .... • ... ~----------Business Name: ~~'\'Y'IM\f\ (}-d,
Address: tooo f>~ W~ Address: lOOo ft.£N.U'v ~~
City: State: ½ip: ____ City: if] ~ State: ~4ip: 0,-Z,.o-z.o
Phone: ______________ Phone: G, tq -4<:/0 -3t£ U:i
Email: Email=------=-------....----,....,..,..,..-----..---
Architect State License: C-1531/o CSLB License#: 3 7 QIY 2-Class: Bi ao-A
Carlsbad Business License# (Required): l2'6'C"::)44-:2,_
APPLICANT CERT/FICA T/ON: I certify that I have read the application and state that the above information is correct and that the
information on the plans is accurate. I agree to comply with al I City ordinances and State laws relating to building
construction.
SIGN:_.,..~ __ .,.V _______ DATE: rr-zz, z.oL(
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
REV. 10/21
Page 2
If applicable, the following document(s) will be required prior to permit issuance:
1. County of San Diego Health Department approval letter -if the business will be operating
any of the following: new apartment building greater than four units, permanent makeup
facility, food and beverage facility, public or community swimming pool. Note: This is not a
complete list. Refer to the San Diego County Food and Housing Division.
https://www.sandiegocounty.gov/deh/fhd/
2. Sewer District Certification -if the project site is outside of Carlsbad Sewer District
boundaries.
Additional Information: This form is prepared by city staff and provided to the applicant prior
to permit issuance. Coordination with the outside sewer district will be required.
3. School District Certification -if project proposes any new square footage.
Additional Information: This form is prepared by city staff and provided to the applicant prior
to permit issuance. Coordination with the school district will be required.
4. Special Inspection Agreement -if project requires a special inspector on site.
Additional Information: Coordination between property owner and state licensed contractor
is required.
5. E-29 Storm Water Pollution Prevention Plan -if the project proposes any new square
footage or soil disturbance.
6. B-59 Waste Management Plan -if the project proposes any new square footage or if the
valuation of alteration is greater than $200,000.
Please contact the building division with any questions on these documents:
Building@CarlsbadCA.gov
760-602-2719
' '
THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _
A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON
SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO
PERMIT ISSUANCE.
(OPTION A): LICENSED CONTRACTOR DECLARATION:
lherebyaffirmunderpenaltyofperjurythatlamlicensedunderprovisionsofChapter9(commencingwithSection7000)ofDivision3
of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the
following declarations (CHOOSE ONE):
DI have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued. Policy No .. _________________________________________ _
-~
[3}<have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: Insurance Company Name:------------~----------
Policy No. 5Y::!0,:2Z-3::: Expiration Date: __ .._.J'2-=-,( ..... 1,_,.l .... w ... ~2~,,__ ___ _
-OR-I 1
D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code,
Interest and attorney's fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (I) Civil Code).
lender's Name: ______________________ lender's Address: _____________________ _
CONTRACTOR CERTIF/CA TION; The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and
utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan ore not
approved for canstruction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct
dimensions af; the property, bulldings, structures and their setbacks from property lines and from one another; access roods/easements, and utilities. The existing and proposed use of each building
as stated is true and carrect; all easements and other encumbrances ta development have been accurately shown and labeled os well as all on-site grading/site preparation. All improvements
existing on the property were campleted in accordance with all regulations in existence at the time of their construction, uni otherwise noted.
NAME (PRINT): ~~'(~ V,cHf( SIGNATURE: _________ DATE: IC· Zl-Z O c...l
Note: If the person signing above Is an authorized agent for the contractor provide a ----------------------·
(OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such
work himself or through his own employees, provided that such Improvements are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
-OR-
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
-OR-
DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
AND,
D FORM 8-61 "Owner Builder Acknowledgement and Verification Form# is required for any permit Issued to a property owner.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed
contractors. / understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is
submitted or at the following Web site: http:Ilwww.leginfo.ca.gov/calaw.html.
OWNER CERTIF/CA TION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and urilities/utl/ity
easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved for
construction and may be required to be altered or removed. The city's approval of the appllcation is based on the premise that the submitted documents and plans show the correct dimensions of;
the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utllities. The existing and proposed use of each building as stated is true
and correct; all easements and other encumbrances to development have been accurately shown ond labeled as well as all on·site grading/site preparation. All improvements existing on the property
wtrt! completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted.
NAME (PRINT): SIGN: __________ DATE: ______ _
Note: If the person signing above is an authorized agent for the property owner include form B-62 signed by property owner.
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
2 REV. 10/21
I
PERMIT INSPECTION HISTORY for (CBC2021-0453)
Permit Type: BLDG-Commercial
Work Class: Tenant Improvement
Status: Closed -Finaled
Scheduled Actual Inspection Type
Date Start Date
11/21/2022 11/21/2022 BLDG-Final Inspection
Checklist Item
Application Date: 11/23/2021 Owner: HAMANN OAK PROPERTIES LP
Issue Date: 01/18/2022 Subdivision: CARLSBAD TCT#97-13-02
Expiration Date: 04/17/2023
IVR Number: 37245
Address: 2856 WHIPTAIL LOOP
CARLSBAD, CA 92010-6708
Inspection No. Inspection Primary Inspector Reinspection Inspection
Status
197097-2022 Partial Pass Tim Kersch Reinspectlon Incomplete
COMMENTS Passed
BLDG-Building Deficiency No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final Yes
BLDG-Electrical Final No
11/23/2022 11/23/2022 BLDG-Final Inspection 197323-2022 Passed Tim Kersch Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
Wednesday, April 9, 2025 Page 4 of4
PERMIT INSPECTION HISTORY for (CBC2021-0453)
Permit Type: BLDG-Commercial Application Date: 11/23/2021 Owner: HAMANN OAK PROPERTIES LP
Work Class: Tenant Improvement Issue Date: 01/18/2022 Subdivision: CARLSBAD TCT#97-13-02
Status: Closed -Finaled Expiration Date: 04/17/2023 Address: 2856 WHIPTAIL LOOP
IVR Number: 37245 CARLSBAD, CA 92010-6708
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
BLDG-22 Sewer/Water 188586-2022 Passed Tim Kersch Complete
Service
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
08/12/2022 08/12/2022 BLDG-12 Steel/Bond 189044-2022 Partial Pass Tim Kersch Relnspectlon Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Virtual inspection. Deputy report provided. Yes
09/27/2022 09/27/2022 BLDG-84 Rough 192735-2022 Partial Pass Tim Kersch Re inspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/05/2022 10/05/2022 BLDG-83 Roof $heating, 193411-2022 Passed Tim Kersch Complete
Exterior Shear (13, 15)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear Panels-HD (ok Yes
to wrap)
BLDG-15 Roof Yes
Sheathing-Reroof
10/07/2022 10/07/2022 BLDG-17 Interior 193637-2022 Cancelled Tim Kersch Reinspectlon Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
10/19/2022 10/19/2022 BLDG-85 T-Bar, Ceiling 194488-2022 Passed Tim Kersch Complete
Grids, Overhead
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
Wednesday, April 9, 2025 Page 3 of 4
PERMIT INSPECTION HISTORY for (CBC2021-0453)
Permit Type: BLDG-Commercial Application Date: 11/23/2021 Owner: HAMANN OAK PROPERTIES LP
Work Class: Tenant Improvement Issue Date: 01/18/2022 Subdivision: CARLSBAD TCT#97-13-02
Status: Closed -Finaled Expiration Date: 04/17/2023 Address: 2856 WHIPTAIL LOOP
IVR Number: 37245 CARLSBAD, CA 92010-6708
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
04/26/2022 04/26/2022 BLDG-24 Rough/Topout 181370-2022 Passed Tim Kersch Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
05/13/2022 05/13/2022 BLDG-43 Air 182704-2022 Passed Tim Kersch Complete
Cond./Furnace Set
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-44 182703-2022 Passed Tim Kersch Complete
Rough/Ducts/Dampers
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
07/14/2022 07/14/2022 BLDG-84 Rough 186878-2022 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
08/02/2022 08/02/2022 BLDG-84 Rough 188261-2022 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
08/05/2022 08/05/2022 BLDG-17 Interior 188587-2022 Passed Tim Kersch Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Wednesday, April 9, 2025 Page 2 of 4
Building Permit Inspection History Finaled
( City of
Carlsbad
PERMIT INSPECTION HISTORY for (CBC2021-0453)
Permit Type: BLDG-Commercial Application Date: 11/23/2021 Owner: HAMANN OAK PROPERTIES LP
Work Class: Tenant Improvement Issue Date: 01/18/2022 Subdivision: CARLSBAD TCT#97-13-02
Status: Closed -Finaled Expiration Date: 04/17/2023 Address: 2856 WHIPTAIL LOOP
IVR Number: 37245 CARLSBAD, CA 92010-6708
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
03/18/2022 03/18/2022 BLDG-21 178627-2022 Passed Tim Kersch Complete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
03/28/2022 03/28/2022 BLDG-84 Rough 179184-2022 Partial Pass Tim Kersch Re inspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
03/30/2022 03/30/2022 BLDG-17 Interior 179366-2022 Passed Tim Kersch Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Repair of electrical room. Yes
To one hour.
04/11/2022 04/11/2022 BLDG-14 180224-2022 Partial Pass Tim Kersch Re inspection Incomplete
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
04/14/2022 04/14/2022 BLDG-14 180579-2022 Passed Tim Kersch Complete
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
04/19/2022 04/19/2022 BLDG-16 Insulation 180815-2022 Passed Tim Kersch Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
04/21/2022 04/21/2022 BLDG-17 Interior 181076-2022 Partial Pass Tim Kersch Re inspection Incomplete
Lath/Drywall
Wednesday, April 9, 2025 Page 1 of 4
DATE: DEC.24,2021
JURISDICTION: CARLSBAD
• lW
INTERWEST
'>Al'[t, 11 C MPANi
□ APPLICANT
□ JURIS.
PLAN CHECK#.: CBC-2021-0453.RCl
PROJECT ADDRESS: 2856 WHIPTAIL LOOP
PROJ ECT NAME: CAMSTON WRATHER -T.I.
SET: II
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at lnterwest
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to :
~ lnterwest staff did not advise the applicant that the plan check has been completed .
D lnterwest staff did advise the applicant that the plan check has been completed .
Person contacted : Renata Vincente Telephone#: 619-440-7424
Date contacted : (by:
Mail Telephone Fax In Person
0 REMARKS:
By: ALI SADRE S.E., CASp
lnterwest
12/17
Email : renata@hamannco.com
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego Ca li fornia 92 123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Hazardous Materials Questionnaire
County of San Diego, Department of Environmental Health and Quality
PO Box 129261, San Diego, CA 92112-9261
Record ID #: Not in System
Plan Check#: DEH2021-HHMBP-010921
Balance Due: $73.00
(858) 505-6700 (800) 253-9933 www.sdcdehq.org
Business Name
Camston Wrather
Business Contact
Aaron Kamenash
Telephone # Plan File #
(619) 251-3702
Project Address City
2856 WHIPTAIL LOOP
State
CA
Zip Code
92010
APN#
209-120-14-00
Applicant Applicant E-Mail Applicant Telephone#
Renata Vicente renata@hamannco.com (619) 251-3702
The following questions represent the facility's activities, NOT the specific project description.
PART I: FIRE DEPARTMENT -HAZARDOUS METERIALS DIVISION: OCCUPANCY CLASSIFICATION: (Not required for projects within the City of San Diego.)
Indicate by selecting the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are selected, Applicant must
contact the Fire Protection Agency with jurisdiction prior to plan submittal.
Occupancy Rating: B, S1 & S2 Facility's Square Footage (including proposed project): 1645
D Explosive or Blasting Agents □ Organic Peroxides D Water Reaclives □ Corrosives
□ Compressed Gases □ Oxidizers
Pyrophorics
□ Cryogenics □ Other Health Hazards
□ Flammable/Combustible Liquids □ □ Highly Toxic or Toxic Materials □ None of These
□ Flammable Solids □ Unstable Reactives □ Radioactives
PART U· SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION (HMDl: If the answer to any of the questions Is
yes, applicant must contact the County of San Diego Hazardous Materials Division, iri person at 5500 Overland Ave., Suite 110, San Diego, CA 92123, or by phone at (858)
505-6700 prior to issuance of a building permit. FEES ARE REQUIRED.
Project Completion Date: 3/30/2022
YES
1. □
2. □
3. □
4. □
5. □
6. □
7. □
8. □
NO
Ii!]
Ii!]
Ii!]
□
I&]
I&]
I&]
Ii!]
Is your business listed on the reverse side of this form? (check all that apply).
Will your business dispose of Hazardous Substances or Medical Waste in any amount?
Will your business store or handle Hazardous Substances in quantities equal to or greater than
55 gallons, 500 pounds, or 200 cubic feet?
Will your business handle carcinogens or reproductive toxins in any quantity?
Will your business use an existing, or install an underground storage tank?
Will your business store or handle Regulated Substances (CalARP)?
Will your business use or install a Hazardous Waste Tank System (Title 22, Article 1 0)?
Will your business store petroleum in tanks or containers at your facility with a total storage capacity
equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act).
□
□
□
CalARP Exempt
CalARP Required
CalARP Complete
Review Date:
PART m: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCDI: If the answer to Question #1 is 'Yes' and the answer to Question #2 is 'No', the applicant
must contact the APCD prior to the issuance of a building or demolition permit. If any answer to Questions #3, #4, or #5 Is 'Yes', the applicant must contact the APCD prior to
the Issuance of a building or demolition permit. If the answer to Question #3 or #4 is 'Yes', the applicant may need to submit an asbestos notification form to the APCD at
least 10 working days prior to commencing demolition or renovation (some residential projects may be exempt from the notification requirements). Contact the APCD at
10124 Old Grove Road, San Diego, CA 92131 or telephone (858) 586-2600 for more information.
1.
2.
3.
4.
YES NO
□ I&]
□ □
□ □
□ I&]
WIii any existing building materials be distu rbed as part of this project? (If the answer is 'Yes', an asbestos survey may be required.)
Has a survey been performed to determine the presence of asbestos containing materials?
Will the project Involve handling or disturbance of any asbestos containing materials?
WIii the project involve the removal of any load supporting structural member?
5. □
□
I&]
□
Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD
factsheet at http://www.sdapcd.org/info/facts/permlts.pdf
6. (ANSWER ONLY IF QUESTION 5 IS 'YES') Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? Search
the California School Directory at http://www.cde.ca.gov/re/sd/ for public and private schools or contact the appropriate school district.
Briefly describe business activities: Briefly describe proposed project:
Recource Recovery Competition of office area improvements
I declare under penalty of perjury that to the best of my knowledge and belief, the responses made herein are true and correct. l&I; Fees Acknowledged: 1&1
Renata Vicente
Name of Owner or Authorized Agent
FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:
BY:
EXEMPT OR NO FURTHER INFORMATION
REQUIRED
COUNTY-HMO' APCD
;?-(Or.
[.:>~ % f.P ~EVI -·oNEo 0a
M. Martinez
SICNl,TURE
12/15/2021
FOR OFFICIAL USE ONLY
RELEASED FOR BUILDING PERMIT BUT NOT FOR
OCCUPANCY
COUNTY-HMO APCD
12/8/2021
Date
DATE: __________ _
RELEASED FOR OCCUPANCY
COUNTY-HMO APCD
• A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply.
DEHQ HMD HMBP Questionnaire v 2.0 (812021)
Printe,fon: 12/1512021 @ 10:13 AM
Building Permit Finaled
Revision Permit
Print Date: 04/09/2025
Job Address: 2856 WHIPTAIL LOOP, CARLSBAD, CA 92010-6708
Permit No:
Status:
{city of
Carlsbad
PREV2022-0059
Closed -Fina led
Permit Type: BLDG-Permit Revision Work Class: Commercial Permit Revision
Parcel #: 2091201400 Track #:
Valuation: $0.00 Lot#:
Occupancy Group: B/M/Sl/Fl Project#:
#of Dwelling Units: Plan#:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition: 2019
Sprinkled: Yes
Project Title:
Construction Type:IIIB
Orig. Plan Check#: CBC2021-0453
Plan Check #:
Applied: 05/19/2022
Issued: 07/29/2022
Finaled Close Out: 04/09/2025
Final Inspection:
INSPECTOR:
Description: CAMSTON WRATHER: ADD 765 SF MEZZANINE FOR STORAGE// NEW PARTIONS // NEW ROOF PENETRATIONS EQUIPMEN-
VENTILATION
Applicant :
HAMANN CONSTRUCTION
REBECA MULLEN
1000 PIONEER WAY
EL CAJON, CA 92020-1923
(619) 440-7424
FEE
BUILDING PLAN CHECK FEE (manual)
BUILDING PLAN REVIEW-Revisions
Total Fees: $379.50
Building Division
Property Owner:
HAMANN OAK PROPERTI ES LP
1000 PIONEER WAY
EL CAJON, CA 92020
(619) 440-7424
Total Payments To Date: $379.50
Contractor:
HAMANN CONSTRUCTION
1000 PIONEER WAY
EL CAJON, CA 92020-1923
(619) 440-7424
Balance Due:
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
AMOUNT
$315.00
$64.50
$0.00
Page 1 of 1
{'cityof
Carlsbad
PLAN CHECK REVISION OR
DEFERRED SUBMITTAL
APPLICATION
8-15
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www .carlsbadca.gov
Original Plan Check Number C.f!e ...... 2G2\ u y c, "'-I
Project Address 2, ~ 5(.; v..: r\,\. r ·h1-L ~ kc r
Plan Revision Number QRD/ 2D22,-: C()~
General Scope of Revision/Deferred Submittal: .J ll-~ r 1., i'\ lUr\. u .. hQQh , '"t6 ,; ~ -'YY\.L ~ :y:nu ·~
)UV-..: (Y\Alv\. 51>t'.'-t-l/,:n,d:-I <lo,,t 1'-...: ~tul:\-u."YY) +1. .it '\-V-<\ { /\(Y\h ~A,\.U"Yt,
CONTACT INFORMATION:
Phone G IC\ -Lft..{ ~ :'.\L{, LY Fax ---~----='-+-, ,__ ________ _
Address kcc {)\"-· nA < 1. t·i... Ct,J City t-! L.Al,~ Z. n2 ..... 2~ 'P-----
EmaifAddress e<J~cc..._ 0 hL\,)'tlCttlr\Cu e~n,
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1 . Elements revised: GJ-1rans G!/cafcufations D Soils D Energy D Other
2. 3.
Describe revisions in detail List page(s) where each
revision is shown
r ~"t"\. -'\:,..t,C!, 'rv I e~,t Y,,U{'Yl,, Ult .. JL~ i t: e,·l. A \u., , f\\t. \ ,
l I , I
/><tlJ'l-
\ '\ \)... )\,\1\,, .... h. .. \. '2-t.l..-~ ~ C.£\1;,n Yh l ii; ,,<c::\-un A {LO i 104
()
{Y\. .e,,:i--~
u A\os
&: uv ~. ~-:v --1/1....< \---u, "YVl -t',-tt J.le,~ Ale~
I
\)\.:_¾ .\ . \ -h,t{..d·'l{..'" ,.d(__ (~ t,-4._I,_ I 5u.,, c.·i 0~3
\~v~ 'J-\'d.t.t°
I
L-{'-l,'r'Yl~ -\;7. t-,U,1 P<: ~' }')'\,\ )'\,I. i'-'\ ~"}vv--....t--\
-, . ' :n,J~.( C\e..0h,C~.-:,....L -~n o-it-\C.l b -, JA l\1,,t,.1 l yYUYV\. C ---.,JfV_.._·t. j
4.
// " Does this revision, in any way, after the exterior of the pro ·ect? D Yes No
5. / 0 No Does this revision add ANY new floor area(s)? [SJ Yes
6. Does this revision affect any fire related issues? D Yes / G No
7. Is this a complete set? ~es [_.:.J I .Jo
£$'Signature 'i:'YY4'-lu "'-Date 6 /l'i5 (2-2-
1635 Faraday Avenue, Carlsbad, CA 92008 ftr 760-602-2719 ,Eax: 760-602-8558 .E.maitbuilding@carfsbadca.gov
www.carlsbadca.gov
DATE: July 28, 2022
JURISDICTION: Carlsbad
• 1W
INTERWEST
A SA"Ebuill COMPANY
PLAN CHECK#.: CB-PREV2022-0059.RC3 SET: IV
PROJECT ADDRESS: 2856 Whiptail Loop East
□ APPLICANT
□ JURIS.
PROJECT NAME: Revision #1 of Comston Wrather -Com -TI (CB-CBC2021-0453)
[:8J The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The check list transmitted herewith is for the applicant's information. The plans are being held at
lnterwest until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person .
D The applicant's copy of the check list has been sent to the jurisdiction at:
[:8J lnterwest staff did not advise the applicant that the plan check has been completed.
D lnterwest staff did advise the applicant that the plan check has been completed.
Person contacted : Telephone#:
Date contacted: (by: ) Email:
Mail Telephone Fax In Person
0 REMARKS: Set Ill is paper, partial set.
By: Greg Favereaux, P.E.
lnterwest
Received on: -
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: June 1, 2022
JURISDICTION: Carlsbad
PLAN CHECK#.: CB-PREV2022-0059
• 1W
INTERWEST
A SAFl!bv,lt COMPANY
SET: I
PROJECT ADDRESS: 2856 Whiptail Loop East
□ APPLICANT
□ JURIS.
PROJECT NAME: Revision #1 of Comston Wrather -Com -TI (CB-CBC2021-0453)
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
C8J The check list transmitted herewith is for the applicant's information. The plans are being held at
lnterwest until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
C8J The applicant's copy of the check list has been sent to the jurisdiction at:
D lnterwest staff did not advise the applicant that the plan check has been completed.
C8J lnterwest staff did advise the applicant that the plan check has been completed .
Person contacted : Rebeca Mullen Telephone #: 619-440-7 424
Date contacted: (by: ) Email: Rebeca@hamannaco.com
Mail Telephone Fax In Person
0 REMARKS:
By: Greg Favereaux, P.E.
lnterwest
Received on: -
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92 123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad CB-PREV2022-0059
June 1, 2022
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: CB-PREV2022-0059 JURISDICTION: Carlsbad
PROJECT ADDRESS: 2856 Whiptail Loop East
FLOOR AREA: 7955 sq ft
Revision Area
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: June 1,2022
FOREWORD (PLEASE READ):
STORIES: 2
HEIGHT: 40 ft
DATE PLANS RECEIVED BY
ESGIL CORPORATION: -
PLAN REVIEWER: Greg Favereaux, P.E.
This plan review is limited to the technical requirements contained in the California Residential
Code, California Building Code, California Plumbing Code, California Mechanical Code,
California I Electrical Code and state laws regulating energy conservation, noise attenuation and
access for the disabled. This plan review is based on regulations enforced by the Building
Department. You may have other corrections based on laws and ordinance by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Present California law mandates that construction comply with the 2019 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2019 CRC, 2019 CBC,
2019 CPC, 2019 CMC and 2019 CEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2019 California Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad CB-PREV2022-0059
June 1, 2022
GENERAL
1. Please make all corrections, as requested in the correction list. Submit FOUR new complete
sets of plans for commercial/industrial projects (THREE sets of plans for residential projects).
For expeditious processing, corrected sets can be submitted in one of two ways:
a. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad
Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The
City will route the plans to lnterwest and the Carlsbad Planning, Engineering and Fire
Departments.
OR;
b. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City
Planning, Engineering and Fire Departments until review by lnterwest is complete.
STRUCTURAL
2. For the new guard rail, also include a detail where the guard is supported by beam/header
below. Provide calculations showing adequacy of connection as needed, per Section 1607.8.1.
3. Foundation details show new footing to be placed into existing slab -Provide a method to
ensure the foundations do not experience significant differential settlement. If epoxy anchors
are to be used, call out epoxy type, including ESR-ICC #, and note that special inspection will
be required. Section 1705.3.
ADDITIONAL
4. There are no Mechanical, Plumbing, or Electrical comn:ients at this time.
5. Please provide a response list indicating where each correction item has been addressed on
the plans. I.e., specify the plan sheet, note, or detail number, calculation page, etc., where the
item is corrected on the plans.
6. Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located in the plans. Have changes been made to the plans not resulting from
this correction list? Please indicate: □Yes □ No
7. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake Drive, Suite 208,
San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review
for your project. If you have any questions regarding these plan review items, please contact
Error! Reference source not found. at lnterwest. Thank you.
Carlsbad CB-PREV2022-0059
June 1, 2022
Carlsbad CB-PREV2022-0059
June 1, 2022
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
0059
PLAN CHECK#.: CB-PREV2022-
PREPARED BY: Greg Favereaux, P.E. DA TE: June 1, 2022
BUILDING ADDRESS: 2856 Whiptail Loop East
BUILDING OCCUPANCY:
BUILDING AREA Valuation
PORTION (Sq.Ft.) Multiplier
Emp Entrance 5067
Mezzanine 765
Lab 2123
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code CB By Ordinance
1997 UBC Building Permit Fee ~
rKrrn,
1997 UBC Plan Check Fee _• J
Type of Review: □ Complete Review
D Repetitive Fee
""" Repeats
• Based on hourly rate
Comments:
D Other
GJ Hourly
EsGil Fee
Reg. VALUE
Mod.
D Structural Only
31 Hrs.@*
=====$=1=0=5-=00=
($)
$315.001
Sheet 1 of 1
Sheet#
1
2-7
8
9-11
12-14
Camston Wrather Mezzanine
Structural Calculation Index
Loads
Framing
Lateral Loads
Shear Walls
Footings
3/28/22
Description
Cl:'.
0 LL w z
Z LL Z <oO ~o~ W 1Y < ~ ::::!
0.LL~~ (/) z w 0 1.0-> <D -O t---(/)f--
0) 0 Z Z
lt)..J OQ~ o..J <t--a.
o-o::~S , <t wa.o
Nt-I~W N 0. ~ (/)
0 -~zZ :I: -0
N>3:zw~ 0 c., Cl:'. w~~~~lD
00 ~ 0 Z < t-w 0. N u (/) a.
>-1--0
ON en ON -.::t-0 Lt) ~N o-0 NO) 0 ~ ~-0) L() I
0 N N N
0
N > w ('<) ~ L{)
-.::t" Q. 0 I
~
N 0
N
0 co
0
F= U)() ('2.lf JZ:..r) •
~---{WN"r:>
,J~J~
t-11~
""61 L-1 f.Jt:..-1
Ml'?~
"1~(!) ~
f,~ .. .,.~
t .o
1, f::;,
'7.,tl
~ ~ [ "2.,t) f-!>Y t? ,_
1 "t ~ (~e ~ -r 7T';r,7.,c.,s, =' ~
r .....
--
-
~JI h 1~::
FJ-z... ~rt)..{J~
~\.49~ ~,J~
I .t ,1,. ~.,
t, ~ = l "Z./''!f,r-/ t.-; 1-;J; 7 c...,,, '::-C-Z$
Lt.-: '?O
Red-I65T .. Joist Allowable Uniform Load (PLF)
l~ll l~TI. lffllt 11 .
l~U. .115\ll. i.omi. 12sx
386 444 407 469
347 482 " 509 • 522 * * 548 * 562 *
371 340 391 349 401 358 411 36f~:421 375 432" ':384
310 426 • 436 • 447 * 458 • 469 • ..
292 336 300 345 307 353 315 362 322 371 330
210 365 277 375 • 384 • 393 * 403 •
276 325 289
442
480
379
412
332 245 28?. ,2~2 302 269 . 309 m;
146 307' i94 328 249 -.336 * 3(5
282 • 353 ~,-361
194 223 223 256 239
'1.-()u, ~ \ ~' t,1<
I ()"1,, (.. v7 d' J<
.. .. . ~:; 10-<..»
275 245 282 251 289 257 296
.:-i ~6 -4,~ ,~~
* 583
38lh 448 389 448 389 .. 487 * 487
334 385 334 385 334 385
• 418 • 418 * 418
293 337
* ''35f 293 337 ~J.;;i.m
* 366 • • '366
261 300 261 300 261 300
ii't..:: r ,z. ~~
1-L ~ I t..~
tJ'f:.. ~~r>1-i:r ~ ~.:)1,t,. FJ-i:--
ftpt.YJZ-~'-1 ,~ dr,µ-; ,
t=-.U--1 1 -~~~~"
t7L ~ t""Z..¥, ~ 1 _ OJt,,tls--~
~\.. -;. t-Z~-¥~t : I ~~P
I 'I ~(41 ~ & ~L,,
L,A1:?1~ ~At,t·C' ~ r,+1
• v~ .c:,~ 1-z.--~-z,,,
h~;;,4-'u"
L.,~11J~ ... ~-.,(--~ f= ~ 1
, ,~~ LPx-~,.,...-z..
W~t..-, ~--(\.,),:7 tf-r-; ! I ~& ,,
v~ -r J"'..-i..:: '~ y & ~.-..7 : -i -i;.ie,~ I ~~' ~,,. ,;;;~-, · fu., ,;· ,~~ e, I;'-,,-,-:;. ~ t ~ ~4 . .,,
~ vJ;, ,; f"';rl"" 'f-'--1 .• ""?· '::' 7 ~#'(
1• J~ ·4..)<.u-..1( v t-, Jc, iJ4..,.e,.,
-l +~
I y
Project Tille: Camston Wrather Mezzanine
Engineer:
Project ID:
Project Desa: CR# 2207
Description :
Wood Beam Design : FJ3
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7•16
BEAM Size: 4x12, Sawn, Fully Braced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir-Larch Wood Grade : No.2
Fb-Tension 900.0 psi Fe -Prll 1,350.0 psi Fv 180.0 psi Ebend-xx 1,600.0ksi
580.0ksi
Density 31.210 pcf
Fb -Compr 900.0 psi Fe -Perp 625.0 psi Ft 575.0 psi Eminbend -xx
Applied Loads
Unit Load: D = O.Q120, L = 0.1250 klft, Trib=-1.0 ft
Design soounary
Max fb/Fb Ratio = 0.310; 1 lb : Actual : 306.88 psi at Fb : Allowable : 990.00 psi 5.250 ft in Span# 1
Load Comb : +D+L
Max. fv/FvR.atio = 0.126: 1 fv : Actual : 22.65 psi at
Fv: Allowable : 180.00 psi
Load Comb : +D+L
9.590 ft in Span # 1
Max Reactions (k) D 1.
Left Support 0.06 0.66 Righi Support 0.06 0.66
.l.l 'Ji
Wood Beam Design : FH1
.ti
0(0.0120) L(0.1250)
ax s
4 x12
10.50 ft
Transient Downward 0.052in
Ratio 2435
LC: L Only
Transient Upward O.OOOin
Ratio 9999
LC:
Total Downward
Ratio
Total Upward
Ratio
0.057 in
2222
LC:+D+L
0.000 in
9999
LC:
calculations per NOS 2018, lBC 2018, CBC 2019, ASCE 7-16
BEAM Size: 5.25x9.25, Parallam PSL, Fully Unbraced
Using Allowable Stress Design with ASGE 7-10 Load Combinations, Major Axis Bending
Wood Species : iLevel Truss Joist Wood Grade: Parallam PSL 2.2E
Fb ~ Tension 2900 psi Fe · Prll 2900 psi Fv 290 psi Ebend-xx 2200 ksi
Fb-Compr 2900psi Fc-Perp 750psi Ft 2025psi Eminbend-xx 1118.19ksi
Density 45.07 pct
ADJ,Jied Loads
Unit Load: D = 0.10, L = 1.0 k/ft, Trib=-1.0 ft
D..esiQo summary
Max fb/Fb Ratio = 0.554 • 1
fb : Actual : 1,592.32 psi at 4.250 ft in Span# 1 Fb : Allowable : 2,876.67 psi
D{ 10 1 0
Load Comb : +O+L 5.25x9.25
Max fv/FvRatio = 0.408: 1 fv : Actual : 118.41 psi at 7.735 ft in Span# 1 Fv : Allowable : 290.00 psi
Load Comb : +D+L
I i .... 8.50 ft
x ections
Max Reactions (k) .'2 L l.r S. W. f
Left Support 0.43 4.25
Right Support 0.43 4.25
Transient Downward 0.155 in
Ratio 658
LC; LOnly
Total Downward 0.171 in
Ratio 598
LC:+D+L
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Project Title: Camston Wrather Mezzanine
Engineer:
Project ID:
Project Descr: CR# 2207
MultjpJe S{mple Beam
UC#: {c) ENERCALC I
Wood Beam Design : FH2
Calculations per NOS 2018, ISC 2018, CBC 2019, ASCE 7-16
BEAM Size : 6x12, Sawn, Fully Unbraced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir-Larch Wood Gracie : No.2
Fb-Tension 875 psi Fe -Prtl 600 psi Fv 170 psi Ebend-xx 1300ksi
470ksi
Density 31.21 pcf
Fb -Compr 875 psi Fe • Perp 625 psi Ft 425 psi Eminbend -xx
Applied Loads
Unif Load: D = 0.10, L = 1.0 k/ft, Trib=o 1.0 ft
Design Summary
Max fb/Fb Ratio = 0 .661 • 1 fb : Actual : 575.05 psf at 3.250 ft in Span # 1
Fb : Allowable : 870.47 psi
Load Comb : +O+l
Max fv/FvRatio = 0.352 : 1
fv : Actual : 59.91 psi at 0.000 ft in Span# 1 Fv: Allowable : 170.00 psi
Load Comb : +D+L
Max Reactions (k) Q l. Lr 'Ji.. .E !::!
Left Support 0.33 3.25
Right Support 0.33 3.25
Wood Beam Design : FH3
-·--· -.,::. .... -.
.;;;_~~-~._---~--.-1~-__ .__ ----:·-~:-~
ex12
6.50 fl
ax ctions
Transient Downward 0.045 in
Ratio 1750
LC: L Only
Transient Upward 0.000 in
Ratio 9999
LC:
;.,
.•.•...•.• ·----··-·· ··-·· -I
Total Downward
Ratio
Total Upward
Ratio
0.049 in
1591
LC: +D+L
0.000 in
9999
LC:
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 6x8, sawn, Fully Unbraced
Usihg Allawable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir-Larch Wood Grade : No.2 Fb -Tension 750 psi Fe -Pr11 700 psi Fv 170 psi Ebend-xx
Fb -Compr 750 psi Fe -Perp 625 psi Ft 475 psi Eminbend • xx
1300ksi 470ksi
Density 31.21 pcf
Applied Loads
Unif Load: D = 0.10, L :: 1.0 k/ft, Trib=o 1.0 ft
Design Sumn18[)'.
Max fb/Fb Ratio = 0.866; 1
fb : Actual : 648.00 psi at
Fb : Allowable : 748.59 psi
Load Comb : +D+L
2.250 ft in Span # 1
Max. fv/FvRatio = 0.385 : 1 fv : Actual : 65.40 psi at Fv : Allowable ; 170.00 psi 0.000 ft in Span# 1
Load Comb : +D+L
Max Reactions (k) Q .L.
Leff Support 0.23 2.25 Right Support 0,23 2.25
Le .s. .E I:!
... -. --. .... ..... :7"~:---~-------.:~ ~--;:-·,:....:,_-,.-_~_-.;_· ___ •• /;"=.;;.,
,. ,._
ax e ectionS
6x8
4.50ft
Transient Downward 0.037 in
Ratio 1463
LC:LOnly
Transient Upward 0.000 in
Ratio 9999
LC:
Total Downward 0.041 in
Ratio 1330
LC:-+O+L
Total Upward 0.000 in
Ratio 9999
LC:
.Wood Colµrrin ..
L 1 , Buiki:20.22.3.1
DESCRIPTION: Typical Wall Stud
Code References
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-10
General Information
Analysis Method Allowable Stress Design
End Fixities Top & Bottom Pinned
Owrall Column Height
( Used for non-i;/er>der calclifal'ons)
Wood Species Douglas Fir-Larch
Wood Gracie No.2
Fb + 900.0 psi Fv
Fb -900.0 psi Ft
Fe -Prn 1,350.0 psi Density
Fe • Perp 625.0 psi
10 ft
180.0 psi
575.0 psi
31.210 pcf
Project Title: Camston Wrather Mezzanine
Engineer:
Project ID:
Project Descr. CR# 2207
CRSE
Wood Section Name
Wood GradinglManuf.
Wood Member Type
Exact Width
Exact Depth
Area
Ix
ly
Project File: 2207.ed>,
h6
Graded Lumber
Sawn
1.50 in Allow Stress Modification Factors
5.50 in Cf or Cv for Bending 1.30
8.250 in112 Cf or Cv for Compressioi 1.10
20. 797 in"4 Cf or Cv for Tension 1.30
1.547 in"4 Cm : Wet Use f=actor 1.0
Ct: Temperature Fact 1.0
Cfu : Flat Use Factor 1.0
1
E : Modulus of Elasticity . . . x-x Bending
Basic 1,600.0
y-yBending
1,600.0
580.0
Axial
1,600.0ksi
Kf : Built-up columns
Use Cr : Repetitive ?
1.0 NOS153.2
No
Minimum 580.0 Brace condition for deflection (budding) along columns :
X-X (width) axis : Fully braced against buckling ABOlfT Y-Y Axis
Y-Y (depth) axis: Unbraced Length b-buckling ABOlfT X--X Axis"' 1(
Applied Loads Service loads entered. Load Factors will be applied for calculations.
AXIAL LOADS ...
Axial Load at 10.0 ft, Xecc = 0.50 in, Yecc = 1.0 in, D = 0.130, L = 1.340 k
DESIGN SUMMARY
Bending & Shear Check Results
PASS Max. Axial+Bendiog Stress Ratio = 0.5519 : 1 Maximum SERVICE Lateral Load RMCtions ..
Load Combination +D+L Top along Y-'r 0.01225 k Bottom along Y-Y 0.01225 k
Gowming NOS F<rih>htp + Mxx + Myy, NOS Eq. 3.9-Top along X-) 0.006125 k Bottom along X-X 0.006125 k
Location of max.above base 9.933 ft Maximum SERVICE Load Lateral Deflections ... Al maximum location values are .
Applied Axial
Applied Mx
Applied My
Fe : Allowable
PASS Maximum Shear Stress Ratio=
Load Combination
Locatlon of max.above base
Applied Design Shear
Allowable Shear
Load Combination Results
Load Combination Co
OOnly
+D+L
+D+0.750L
+0.60D
Maximum Reactions
0.900
1.000
1.250
1.600
1.470k
-0.1217 k-ft
-0.06084 k-ft
808.37 psi
Along Y-Y -0.04116 in at 5.839 rt above base
for load rombination : +D+l
Along X-X -0.27o7 in at 5.839 ft above base
for load combination : +D+L
Other Factors used to calculate allowable stresses ...
0.01237 : 1 ~ Compression ~
+D+L
10.0 ff
2.227 psi
180.0 psi
Cp Maximum Axial + Bending Stress Ratios
0.585
0.544
0.461
0.376
Stress Ratio Status Location
0.04661 PASS 9.933ft
0.5519 PASS 9.933ft
0.3309 PASS 9.933ft
0.01567 PASS 9.933 ft
Maximum Shear Ratios
Stress Ratio Status Location
0.001216 PASS 10.0 ft
0.01237 PASS 10.0 ft
0.007643 PASS 10.0 ft
0.000410 PASS 10.0 ft
Note: Only non-zero reactions are listed.
X-X Axis Reaction k Y -Y Axis Reaction Axial Reaction
@ Base
My -End Moments k..ft Mx-End Moments
Load Combination
D Only
+D+L
+D+0.750l
+0.600
@Base
...().001
-0.006
-0.005
-0.000
@Top
0.001
0.006
0.005
0.000
@Base @Top
-0.001 0.001
...0.012 0.012
-0.009 0.009
--0.001 0.001
0.130
1.470
1.135
0.078
@ Base @ Top @ Base @ Top
~ ta=! "'?!'?'I ' C,, t..4,...~, 1...rf;( :
~c,k-n <PJ : --Z..~~~ ~H-fr"T"''6-f ~ ~,~
~~ C,A--1-U!"'
q,-r~ (!,,,~? p I ~p~ '-:::' • .,.d-~., ~~ lv v'~lv-J ,_j e.,Jr-r f;> ,t,? _ -/'. )
~l":?/!C-, C-A---"f .:JI r---l-)r \f?uiwr:? 4';,IA./
C
Mark Material n Nall
0 Stucco
1 3J8·cox Plywd 8d
2 3/S'CDX Plw,,d 8d
3 3/B"CDX Plywd 8d
4 3/6"CDX Pl'/Wd 8d
5 15/32"CDX Ptr,vd 10d
6 15/32"CDX Plywd 10d
7 15/32'CDX Piywd 1Qd
8 15/32'CDX Plywd 10d
9 3/B"Struct I Plvwd 8d
10 3/B"Struct I Plvwd Bd
11 3/S"Strucl I Plywd 8d
12 3/8"Strucl I PIYWd Bd
13 15132•sIruct I Pl\tWd 10d
14 I 5/32'Slruct I Plvwo 10d
15 15/32"Strucl I Plywd 10d
16 15/32"Struct I Plywd 10d
17
18
19
20
SHEAR WALL SCHEDULE
Notes 1 • 14 & 21 app_ly_ to all walls
.!)S171EDTLER'· No. 937 8"11E
Engineer's Computation Pad
Nalllna Description Anchor Bolt Sill PL Conn (SPC) Shear Transfer Sheur Notes
Edoe Nall (ENI Field Nall (FN) Size SpaclnQ Size $pacing Type Soacfna PLF 1,2 ,3,◄,5,6,7,8,9, IO, 11.12, 13, 14,21
6' o.c, 6" o.c, 5/8' 48'0.1:. 16d 12· o.c A35 24"o.c. 180 1!l,:?0 a• o.c. 12· o.c. 5/8' 4810.r.. 16d a· o.c A35 24"o.c. 220
4"o.c. 12• o.o. 5/6' , 31:o.c. 16d 6' O,C A35 16"o.c. 320
a•o.c. 12· o.c. 5/8" 16''o.c. 16d 4• o.c A35 12•0.o. 410 16
2· o.c, 12· o.c. 518• 12•0.o. 16d 4• o.c A35 s•o.c. 53() 16
6" o.c. 12· o.c. 518• 1610.c. 16d e• o.c A35 1e•o.o. 310
4• o.c. 12· o.c. 5/8" 12'o.c. 16d 4• o.c A35 8'o.c. 460 16 3• o.c. 12· o.c. 5/8" 24"o.c. SDS1/4x6 6' o.c A35 a•o.c. 600 16, 16
2' o.c. 12' o.c. 5/8" 16"0,C. SDS1/4x6 4• o.c LTP4 s•o.c. 770 16, 16
6'o.c. 12· o.c. 5/8" 48'0.C. 16d a· o.c A35 18"o.c. 230
4"o.c. 12• o.c. 5/8' 16°0.0. 16d 611 0.c A35 12•0.c. 360 16
3• o.c. 12· o.c. 5/8" 12•0.c. 16d 4• o.o A35 B'o.c. 460 16
2· 0.0. 12• o.o. 5/8" 24110.0. SDS1/4x6 6" o.c A35 810.c. 610 16,16
6" o.c. 12· o.c. 518" 1a•o.c. 16d 6''o.c A35 16"o.c. 340
4• o.c. 12· o.c. 518" 12•0.c. 16d 4• o.c A35 a•o.c. 510 16
3• o.c. 12• o.c. 5/8" 24"o.c, SDS1/4x6 e•o.c A35 a•o.c. 665 16,16
2· o.c. 12· o.c. 5/8" 1 s•o.c. SDS1/4x6 4• 0.0 LTP4 a•o,c. 870 15,16
i~ ~-
ir_
~
F
f
<n I
\> 1' ..
~
~-
........
('C\
~:Y:::~ .....JA-t..\,Jf;
~k, ,;;-~i•
V~ ~ ... 44-pte,F.),/ la;-~ W ~ 1. ~ i.:;
1)::;, l-~/G':;: ~d'~-r" '6) ?W ~~ z. /h?:e:>)
:. d>iH'I-::: f ~T:,,¥ I o -.:: 1:f;;, 1,,t' • .-,,.
~Yl ::::--~
IJ(UF"f~ •~/...-~ Z,u1<i .;::";,o f,-h:?vt-,~.,_-:;.-3~,~
L ~ -=-z.:-z . .!.. .,~
V;-~-~◄·~~ ~--?$~ 1/~ :.::.--f -~',(
1J ;; I' ;J;, / 'Z i ~ L.,,z, ;,...~ ~~ ~ .,.......,f'~ I (T.;'T,# \
4' 'fr-"1 "-= I,~~ t (ff' '::." I ~ ... c, J<,r==i'
~HI-:. _... 11 ir~~f,,1~'t-,-t-½ ~~;(_, ';: -I 4,.R
,, tL _ z~()
I ,, fW l,.,~t) ~J ('I>-~(?1" ~' i-?.
J
7
f=durJ~,-I O'I~ ~
TIFIG-A t.... JA,4....\,..1, ~
h1,J'e-e" ,tt.;L, ,J ,t¾U,~ ~ ,J-r~cn... ~,,
9~"~ ~~;:;'4/k';f"~◄
oJ I~ 1tp e I e-' '" .. ~ , ~~
¥ c;,<i:,,f" ~~ w~ (~•~~
Tf r-r ;: 6 i-t""" r , -.:: '0'.l< ~ 1
=-ii 6{) :is,~
I ..f.. .;-.,
---·-· ~--·····.-
A-f '"'?J..P~ ~ ~ i> '? -z., -t5f
o,t--,,J:::: L-;;i;.. K-F-r-~14' <-l~,v ,~.p-,-(-,;;,.\ ! / i,Leo I,,_,.,..,;,,--t 'I' ~ » l"ZAC
-~( (; ,{;, i tsr I
Ll~t1 ~&. u'' w, ~..;$>< -i '~ J-PT1k<
wl ~--~4 ~r 1£L..~
\
: KW 1, Bulki:20.22.3.16
DESCRIPTION: Ftg under SW1,SW2,SW4
Code References
Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-10
General, Information
Material Properties
fc : Concrete 28 day strength
fy : Rebar Yield
Ee : Concrete Elastic Modulus
Coocrete Density
cp Values Flexure
Shear
Analysis Settings
Min Steel % ~ing Reinf.
Min Allow% Temp Reinf. •
Min. Overturning Safety Factor
Add Ftg Wt for Soil Pressure
=
=
=
=
=
Use ftg wt for stability, moments & shears
Add Pedestal Wt for Soll Pressure
Use Pedestal wt for stability, mom & shear
Dimensions
Width parallel to X-X Axis
Length parallel to Z-Z Axis
Footing Thickness
Pedestal dimensions ...
px : parallel to X-X Axis
pz : paraHel to Z-Z Axis
Height
=
:::
=
=
Rebar Centerline to Edge of Concrete ...
at Bottom of footing =
Reinforcing
Bars parallel to X-X Axis
Number of Bars
Reinforcing Bar Size
Bars parallel to Z-Z Axis
=
2.50 ksi
60,0 ksi
3,122.0 ksi
145.0 pcf
0.90
0.750
= 0.00180
= 1~0 : 1
2.0 ft
9,0 ft
24.0 in
6.0 in
60.0 in
1.0 in
3.0 in
Yes
Yes
No
No
Number of Bars = 4
Reinforcing Bar Size = # 4
BandWldth Distribution Check. (ACI 15.4.4.2)
Direction Requiring Closer Separation
# Bars required within zone
Bars along X-X Axis
36.4 %
# Bars required or, each side of zone 63.6%
Applied Loads
P : Column Load
OB : Ovefburden
M-xx
M-zz
V-x
V..z
D
= 0.120
=
=
=
Lr
Project Title: Camston Wrather Mezzanine
Engineer:
Project ID:
Project Descr: CR# 2207
Project FIie: 2207.ec6
RSE (c) ENERCAL I
Soil Design Values
Allowable Soil Beating
Soil Density
Increase Bearing By Footing Weight
Soil Passive Resistance (for Sliding)
SoiVConcrete Friction Coeff.
lncreasu based on footing Depth
Footing base depth below soil surface
Allow press. increase per foot of depth
when footing base is below
=
;::
=
=
=
Increases based on footing plan dime.nsion
Allowable l)fessure increase per foot of depth
when max. length or-width is greater than
L s w
=
E
18.20
0.0
2.0 ksf
110.0 pct
No
250,0 pcf
0.30
1.0 ft
ksf
ft
H
ksf
ft
k
ksf
k-ft
k-ft
k
k
Project Title: Carnston Wrather Mezzanine
Engineer.
Project ID:
Project Oescr: CR# 2207
1 .3.16 CRSE
DESCRIPTION: Ftg under SW1,SW2,SW4
DESIGN SUMMARY --•i41Gii•JQ--
Min. Ratio Item Applied Capacity Gow.ming Load Combination
PASS 0.9905 Soil Bearing 1.981 ksf 2.0 k.sf +0.60D+0.70E about X-X axis
PASS 1.132 OYertuming -X-X 12.740 k-ft 14.418 k-ft +0.60D+0.70E
PASS n/a Overturning -Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS nia Uplift 0.0 k 0.0 k No Uplift
PASS .0000520 Z Flexure (+X) 0.002625 k-Mt 50.472 k-Mt +1.400
PASS .0000520 Z Flexure (-X) 0.002625 k-Mt 50.-4 72 k-ft/ft +1.400
PASS 0.03085 X Flexure (+Z) 2.570 k-ft/ft 83.306 k-ftlft +0.90D+E
PASS 0.008354 X FleX1Jre (-Z) 0.6959 k-ft/ft 83.306 k-ft/ft +1.20D+E
PASS nla 1-way Shear (+X) 0.0 psi 75.0 psi n/a
PASS 0.0 1-way Shear (-X) 0.0 psi 0.0 psi n/a
PASS 0.02634 1-way Shear(+Z) 1.976 psi 75.0 psi +0.90D+E
PASS 0.004971 1-way Shear (-Z) 0.3729 psi 75.0 psi +1.20D+E
PASS n/a 2-way Punching 0.1981 psi 75.0 psi +1.400
Detailed Results
Soll Bearing
Rotati041 Axis & Xecc Zecc Adual Soil Bearing stress @ location Actuaf / Allow
Load Combination ... Gross Allowable (in) Bottom, -Z Top,+Z Lett, -X Right, +X Ratio
X-X, D Only 2.0 n/a 0.0 0.2967 0.2967 o/a n/a 0.148
X•X, +D+0.70E 2.0 n/a 28.629 0.0 0.8359 n/a n/a 0.418
X-X. +D+0.5250E 2.0 n/a 21.4n 0.0 0.6530 n/a n/a 0.327
X-X. +0.600 2.0 n/a 0.0 0.1780 0.1780 n/a n/a 0.089
X-X, +0.600+0.70E 2.0 n/a 47.715 0.0 1.981 n/a n/a 0.991
2-Z. 0 Only 2.0 0.0 n/a n/a n/a 0.2967 0.2967 0.148
Z-Z, +D+0.70E 2.0 0.0 n/a nla n/a 0.2967 0.2967 0.148
Z-Z, +0+0.5250E 2.0 0.0 n/a n/a n/a 0.2967 0.2967 0.148
Z-Z, +0.600 2.0 0.0 n/a nla n/a 0.1780 0.1780 0.089
Z-Z. +0.60D+0.70E 2.0 0.0 n/a n/a n/a 0.1780 0.1780 0.089
Overturning Stability
Rotation Axis &
Load Combination ... Overturning Moment Resls1lng Moment Stability Rat.lo Status
X-X, OOnly None 0.0 k•ff Infinity OK
X-X, +D+0.70E 12.740 k-ft 24.030 k-ft 1.886 OK
X-X, +0+0.5250E 9.555 k-ft 24.030 k-ft 2.515 OK
X-X, +0.600 None 0.0 k-ff Infinity OK
X-X, +0.600+0.70E 12.740 k..ft 14.418 k-ft 1.132 OK
Z-2, D Only None 0.0 k-ft Infinity OK
Z-Z, +D+0.70E None 0.0 k-ft Infinity OK
2-2, +D+0.5250E None 0.Ok..ft Infinity OK
Z-Z, +0.600 None 0.0 k-ft Infinity OK
Z-2, +0.600+0.70E None 0.0 k-ft Infinity OK
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvm.As Actual As PhMan Status k-ft Sufface in"2 in"2 in"'2 k-ft
X-X, +1.400 0.01867 +Z Bottom 0.5184 AsMin 0.930 83.306 OK
X-X, +1.400 0.01867 -Z Bottom 0.5184 AsMin 0.930 83.308 OK
X-X. +1.200 0.0160 +Z Bott.om 0.5184 AsMin 0.930 83.306 OK
X-X, +1.200 0.0160 -Z Bottom 0.5184 AsMin 0.930 83.308 OK
X-X, +1.20D+E 1.533 +Z Bottom 0.5184 AsMin 0.930 83.306 OK
X-X, +1.20D+E 0.6959 -Z Top 0.5184 AsMin 0.930 83.306 OK
X-X, +0.900 0.0120 +Z Bottom 0.5184 .AsMin 0.930 83.306 OK
X-X. +0.900 0.0120 -Z Bottom 0.5184 AsMin 0.930 83.306 OK
X-X, +0.90D+E 2.570 +Z Bottom 0.5184 AsMin 0.930 83.306 OK
X-X, +0.90D+E 0.5219 .z Top 0.5184 .AsMin 0.930 83.306 OK z.z. +1.40D 0.002625 -X Bottom 0.5184 AsMin 0.5511 50.472 OK
Z-Z, -t-1 .400 0.002625 +X Bottom 0.5184 AsMin 0.5511 50.472 OK
• '
A1".4-\
1 ~ I FF====~=:
II 11
4f)
,.,. u,"1 ~¥' ~ G'"
11 •-~V\ -;;: 1,. ( ~
·J+7,, '(A:et:n, ~-~~1 /J,G,
<~ "'£7~ ~;;; s;-~
?iv-"~ w/ ~1-rtrJ ~
l?'( ,e_
~(. ~ ,...-.t+L>--:: ~&,-~~
&IZ T
6/24/22