HomeMy WebLinkAbout1205 AVIARA PKWY; ; CBC2021-0489; PermitBuilding Permit Finaled
{city of
Carlsbad
Commercial Permit
Print Date: 06/26/2025
Job Address: 1205 AVIARA PKWY, CARLSBAD, CA 92011-1276
Permit Type:
Parcel#:
Va luation:
BLDG-Commercial
2120405600
$6,792,673.00
Occupancy Group: S
#of Dwelling Units:
Bedrooms:
Work Class:
Track#:
Lot#:
Project#:
Plan#:
Construction Type:
New
DEV2017-0033
Bathrooms:
Occupant Load:
Orig. Plan Check#: PC2021-0065
Plan Check #:
Code Edition:
Sprinkled:
Project Title: AVIARA APARTMENTS
Description: AVIARA APARTMENTS; NEW (157,420 SF) PARKING GARAGE
Applicant:
CHRIS SCHOENECK
5120 SHOREHAM PL, # UNIT 150
SAN DIEGO, CA 92122-5959
{858) 623-4962
FEE
BUILDING PLAN CHECK FEE (manual)
Property Owner:
AVIARA LP
AUSTIN W
5120 SHOREHAM PL, # 150
SAN DIEGO, CA 92122-5959
(858) 535-1475
BUILDING PLAN REVIEW-MAJOR PROJECTS (LOE)
BUILDING PLAN REVIEW -MAJOR PROJECTS (PLN)
CERTIFICATE OF OCCUPANCY
FIRES Occupancies~ 50,000sq. ft. New
LOW & MODERATE HAZARD STORAGE
581473 -GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION -COMMERCIAL (SMIP)
SWPPP INSPECTION FEE TIER 1 -Medium BLDG
SWPPP PLAN REVIEW FEE TIER 1 -Medium
Total Fees: $17,592.95 Total Payments To Date: $17,592.95
Permit No:
Status:
CBC2021-0489
Closed -Finaled
Applied: 12/27/2021
Issued: 05/25/2023
Finaled Close Out: 06/26/2025
Final Inspection: 06/16/2025
INSPECTOR: Kersch, Tim
Contractor:
WERMERS MULTI-FAMILY CORP
5120 SHOREHAM PL, # STE 150
SAN DIEGO, CA 92122-5959
(858) 535-1475
Balance Due:
AMOUNT
$5,000.00
$581.00
$295.00
$16.00
$971.00
$8,195.00
$272.00
$1,901.95
$292.00
$69.00
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was iss ued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
COMMERCIAL
BU ILDING PERMll
APPLICATION
B-2
Job Address 1205 Aviara Parkway Suite:. _____ APN: 212-040-56-00
Tenant Name #:. _____ _ Lot It: _______ Year Built : 2022-2023 _____ _
Year Built:. __ _ Occupancy: __ _ Construction Type: __ Fire sprinklers0tESQNO A/C:(vYESQNO
n:mr-DE',Cf<JrflOi\l OF WOf{i(: Parl<ing Structure
[Z] Additio11/New:_1_5_8_,_2_·1_2 ________________ i'lew SF and Use,. __________ New SF c1nd Use
______ SF Deck, SF Patio Cover, SF Other (Specify) ___ _
0Tenant Improvement: _____ SF,
_____ SF,
Existing Use: _______ Proposed Use: ______ _
Existing Use: Proposed Use: ______ _
□ Pool/Spa: ____ SF Additional Gas or ElectrrcalFeatures? ____________ _
D Solar: ___ l<W,. ___ Modules, Mounted: 0Roof OGrouncl
D Reroof:. ___________________________________ _
D Plumbing/Mechanical/Electrical
Dother: ______________________________ _
PnlMARY APPLI CANT
Name: Wermers Properties
Address: 5120 Shoreham Place #150
City: San Diego State:_C_A_-'Zip: 92122
Phone: (858) 623-4941
Email: robertog@wermersproperties.com
DESIGN PROFESSIONAL
Name: S\,.Q.~V\ ~ • .\:(,c.,U.., Gv""(\c.r---it.d -P\C>
Address: \ L\ '-\ () 0 '"""'?fr ',ye
City: (-:y{ u.fv'~ State: c, A. Zip: cp .. & ~ 0
Phone: :f\ l{ -\a bq_ • j t (oO
Email: -~,..£:o(2 CAO OA,),.,.~.,~(. .(_u,I"'
Architect State License: \j •• \ °fu3 VJ
PfWPEHTY OWNEn
Name: Aviara LP
Address: 3444 Camino del Rio Noth, Ste 202
City: San Diego state:~Zip:_9_2_10_8 __ _
Phone: (619) 285-5500
Email: Dszuberla@rvmsd.com
CONTRJ.\CTOR OF RECORD
Business Name: Wermers Multi-Family Corp
Address: 5120 Shoreham Place #150
City: San Diego
Phone: (858) 535-1475
State: CA Zip: . ....;;.;92;;.;1.;;;;22;:_ __ _
Email: samd@wermerscompanies.com
CSLB License#: 733553 Class: ·-------
Carlsbad Business License# (Required): BLOS006613-10-2019
APPLICANT CERTIFICATION: /certify that I have read the application and state that theaboveinformationiscorrectand that the
information on the plansisaccurate. lagree to comply with all City ordinances and State laws relating to building
construction. A. 0 l I ,
NAME (PRINT): Richard L. Lemmel SIGN: fttt ~ /jJ., ( (n> DATE: 12/21/21
1635 Faraday Ave Carlsbad. CA 92008 Ph: 760-602-2719 Fax: 750-602-8558 Email: Buildingi@carlsbadca.gov
REV. 07/21
Tl IIS PJ\GE Rl(lUIHED 1Yf PEHIVllT IS5UAI\JCF
t\Llllil.'lli'-l\1f'l:H1•11!1 U\l'-li\' l,,tkll l \ll.li lli'.,(' ,i 'i i Ill U11',Ull0i\lti,.'\' itlt((li\!\l'iWPLIU '{<lWt'lil1 11 Ill l',l(',l)l'i
'ii( ,1,11N1.., t I w; i ()!{1'11 h .•\i\l I\C,l'f'I i FOH t·l t l 1 •:H l:111 II t Y /\i\1 1\I I J l·IO!UD\ l lili'J FUl{l'tl ur: LL I I U ( I', IF.I !UIIU.11 111:11 Jt{ I (J
PFH MI f ISSU.t.\f•KF.
(OPTI Oi'I /\): LICE~ED CONfHACfOH OECU\HATION:
J hcrebyaf firm under penal tyof per jurylhat /0111 licensedw1cle1provisionsof Chapter 9 (wn1mencing with Section 7000) af Division 3
of the Business and Professions Cocle, and my license is in fuU forcenndeffect . I a/so affirm u11dP.r penoltyof pe1juryoneof the
fol/owi11g clec/orotions (Utoosr: ONE):
0 1 ha•,e and will 111ainlair1 J c~ttificale of c:on>t:nl lo S.<:if-int,utc r,1, wo,ker<.;' u,rnpr.:nsation ptuv,ded Uy Section j/UO or the Labo• Cotle. for the µerforrnann? ul the
1.,•1ork v,;hil:h lhis permit b 1s~1.1~d . PolicyNo ______________________________________ _
.()1(-Cl]i have and will 111a1ntai11 \'/o,ker's ccunpcnsaliofl, dS reqwre(I by Ser.lion 1700 or thP. Lalhlr Cuc.le, for the perforn>,mcP. of the work for which tlus pe,m11 is issued
My workers' compensation insurance earner and polir.y m11nh~r are: Insurance Company Name: -~,pre.:,S:. I:~~"\C..C..-~f~ «r-=------
Policy No. W e:.',v'C. !> I <f> \ ~ .. _._ _______________ E,tpiratio11 Date: __.l.,,,O_·_,l_·-='U>=~'.2-,-c._'.!,.,_ ___ q ____ _
•Oil•
O certilicate or Exemption: I certify that in the pe,forn,ancc or the wor!t for which this permit i~ issued, I shall not employ any person in any manner so as 10 bec0n,~
subject 10 the workers' compensation laws of California. WAflNING: Failure to secure workers compensation coverage Is unlawful and shall subject an employer to
criminal penalties and civil fine$ up to $Hl0,000.00, in additlo,, the lo the cost of compensation, damages as pro'lided ror in Section 3706 of the lnbor Code,
interest and attorney's fees.
_c;pt\lSTRUCTIOi\l LENDII\JG AGf.i'ICY, IF AI\IY:
I hereby aifim• that there Is a construction lending agency for the performance of the work this per mil is i5sued (Sec. 3097 (i) Civil Code).
I.ender's Narne: ____________________ Lender's llddress: ___________________ _
CONTRACTOR CERT/FICA TION: I certify that/ have read the app i tionand stat
the information on the plans isaccurate. lagree to comply w· all City ordina
construction.
{OPTION BJ: O\,Vi\lF.R•BUILDER DECLARJ.\TION:
that the above informat ion is correct and that
es and State laws relating to building
I hereby affirm that I am exempt from Contractor 's License Law for the following reason: n I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
L.rrJ44, Business and Professions Code: The Contractor's License Law does not apply to an owner or properly who builds or improves thereon, and who does such
work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner•builder will have the burden of proving that he did not build or improve for lhe purpose of sale).
·OR-
D 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business ancl Professloos Cocle: The
Contractor's License l aw does not apply to an owner or property who builds or Improves thereon, and contracts for such projects with contractor(s) licensed
pursuant lo the Contractor's License Law).
·OR-□, am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
D FOAivl 8-61 uowner Builder /\cknowle<.Jgement and Verification Form" i--; (equired for all'( pernut issued to:) propenv owner
By rny-sIgn1cure bt!low I ac:<nowledge lh::it, e:,cept for my persont1I res,denc~ 11) \-'thich I must h/Ne resid~.l for at It.Ht one year pdt:ir to compl~tlon of th'"!
improvements covered by this p~rmit, I cannot h?gally sell a structuf'e that I have built :ts an owner•IH1ilder 1f 1t ha-; not b'.:?en constructed in its enttrety by licensed
rntHrac.tors. I understand that a copy of the applicable law, Section 7044 of the Businessand Professions( ode, lsavailableupon request when this applicat ion is
submitted or at the following Web site: http:I/www.leginfo.ca.gov/ ca/aw. html.
OWNER CERT/FICA T/ON: /certify that I have read the application and state that the above information iscorrectand that the
information on the plans is accurate. /agree to comply with all City ordinances and State lawsrelating to building
construction.
NAME (PRINT): SIGN: __________ DATE: ______ _
Note: If the person signing above Is an authorized agent for the property owner Include form 8·62 signed by property owner.
1635 Faraday Ave Carlsbad, Cll 92008 Ph; 760-602·2719 Fax: 760·602·8558 Email: 8\lllding@carlsbadca.gov
2 REV. 07121
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
04/11/2024 04/11/2024 BLDG-84 Rough 244404-2024 Partial Pass Tim Kersch Re inspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks}
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
04/16/2024 04/16/2024 BLDG-84 Rough 245068-2024 Partial Pass Tim Kersch Re inspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks}
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
06/16/2025 06/16/2025 BLDG-Final Inspection 288030-2025 Passed Tim Kersch Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
Thursday, June 26, 2025 Page 44 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 9201 1-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
BLDG-14 238719-2024 Partial Pass Tim Kersch Re inspection Incomplete
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/20/2024 02/20/2024 BLDG-14 239018-2024 Passed Tim Kersch Complete
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/29/2024 02/29/2024 BLDG-14 240054-2024 Partial Pass Tim Kersch Reinspectlon Incomplete
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
03/14/2024 03/14/2024 BLDG-14 240971-2024 Partial Pass Tim Kersch Reinspection Incomplete
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
03/28/2024 03/28/2024 BLDG-84 Rough 242376-2024 Passed Tim Kersch Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
04/01/2024 04/01/2024 BLDG-84 Rough 243724-2024 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
Thursday, June 26, 2025 Page 43 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
01/24/2024 01/24/2024 BLDG-11 237609-2024 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 237610-2024 Partial Pass Tim Kersch Re Inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/25/2024 01/25/2024 BLDG-13 Shear 237797-2024 Partial Pass Tim Kersch Reinspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 237794-2024 Partial Pass Tim Kersch Relnspection Incomplete
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-34 Rough 237795-2024 Partial Pass Tim Kersch Re Inspection Incomplete
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/29/2024 01/29/2024 BLDG-13 Shear 237918-2024 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 237916-2024 Partial Pass Tim Kersch Reinspection Incomplete
Frame/Steel/Bolting/We
!ding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-34 Rough 237917-2024 Partial Pass Tim Kersch Reinspection Incomplete
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/06/2024 02/05/2024
Thursday, June 26, 2025 Page 42 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type:
Work Class:
Status:
Scheduled
Date
BLDG-Commercial Application Date:
New Issue Date:
Closed -Finaled Expiration Date:
IVR Number:
Actual Inspection Type
Start Date
Inspection No.
Checklist Item
Are inactives slopes properly
stabilized?
Are areas flatter than 3:1
covered or protected?
Are sediment controls properly
maintained?
Are erosion control BMPs
functioning properly?
Are natural areas protected
from erosion?
Do basins appear to be
maintained as required?
Are perimeter control BMPs
maintained?
Is the entrance stabilized to
prevent tracking?
Have sediments been tracked
on to the street?
Are storm drain inlets
protected and maintained?
Have materials collected
around the storm drains?
Has sediment accumulated on
impervious surfaces?
Are dumpsters and trash
receptacles covered?
Has trash/debris accumulated
throughout the site?
Are stockpiles and spoils
protected from runoff?
Are all storage areas clean
and maintained?
Are spill kits provided onsite?
Are washout areas maintained
and protected?
Were spills/leaks observed
during the inspection?
Were there any discharges
during the inspection?
Is the SWPPP wall map up to
date and accurate?
Was the SWPPP or Erosion
Control Plan reviewed?
Are portable restrooms
properly positioned?
Do portable restrooms have
secondary containment?
Are BMPs stockpiled for
emergency deployment?
COMMENTS
Thursday, June 26, 2025
12/27/2021
05/25/2023
10/15/2024
37800
Inspection
Status
Owner: AVIARA LP
Subdivision: RANCHO AGUA HEDIONDA POR
OF
Address: 1205 AVIARA PKWY
CARLSBAD, CA 9201 1-1276
Primary Inspector Reinspection Inspection
Passed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Page 41 of 44
I PERMIT INSPECTION HISTORY for (CBC2021-0489)
Application Date: 12/27/2021 Owner: AVIARA LP Permit Type: BLDG-Commercial
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
Status: Closed -Finaled Expiration Date: 10/15/2024
IVR Number: 37800
OF
Address: 1205 AVIARA PKWY
CARLSBAD, CA 92011-1276
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector Reinspection Inspection
Status
01/23/2024 01/23/2024 BLDG-11 237459-2024 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 237460-2024 Partial Pass Tim Kersch Relnspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-SW-Inspection 237504-2024 Passed Tim Kersch Complete
Thursday, June 26, 2025 Page 40 of 44
'
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type:
Work Class:
Status:
Scheduled
Date
BLDG-Commercial Application Date:
New Issue Date:
Closed -Finaled Expiration Date:
IVR Number:
Actual Inspection Type
Start Date
Inspection No.
Checklist Item
Are inactives slopes properly
stabilized?
Are.areas flatter than 3:1
covered or protected?
Are sediment controls properly
maintained?
Are erosion control BMPs
functioning properly?
Are natural areas protected
from erosion?
Do basins appear to be
maintained as required?
Are perimeter control BMPs
maintained?
Is the entrance stabilized to
prevent tracking?
Have sediments been tracked
on to the street?
Are storm drain inlets
protected and maintained?
Have materials collected
around the storm drains?
Has sediment accumulated on
impervious surfaces?
Are dumpsters and trash
receptacles covered?
Has trash/debris accumulated
throughout the site?
Are stockpiles and spoils
protected from runoff?
Are all storage areas clean
and maintained?
Are spill kits provided onsite?
Are washout areas maintained
and protected?
Were spills/leaks observed
during the inspection?
Were there any discharges
during the inspection?
Is the SWPPP wall map up to
date and accurate?
Was the SWPPP or Erosion
Control Plan reviewed?
Are portable restrooms
properly positioned?
Do portable restrooms have
secondary containment?
Are BMPs stockpiled for
emergency deployment?
COMMENTS
Thursday, June 26, 2025
12/27/2021
05/25/2023
10/15/2024
37800
Inspection
Status
Owner: AVIARA LP
Subdivision: RANCHO AGUA HEDIONDA POR
OF
Address: 1205 AVIARA PKWY
CARLSBAD, CA 92011-1276
Primary Inspector Reinspection Inspection
Passed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Page 39 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
01/17/2024 01/17/2024 BLDG-11 236932-2024 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 236933-2024 Partial Pass Tim Kersch Reinspectlon incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-SW-Pre-Con 237121-2024 Passed Tim Kersch Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/22/2024 01/18/2024 BLDG-11 237135-2024 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 237136-2024 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-SW-Inspection 237474-2024 Passed Tim Kersch Complete
Thursday, June 26, 2025 Page 38 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type:
Work Class:
Status:
Scheduled
Date
BLDG-Commercial Application Date:
New Issue Date:
Closed -Finaled Expiration Date:
IVR Number:
Actual Inspection Type
Start Date
Inspection No.
Checklist Item
Are inactives slopes properly
stabilized?
Are areas flatterthan 3: 1
covered or protected?
Are sediment controls properly
maintained?
Are erosion control BMPs
functioning properly?
Are natural areas protected
from erosion?
Do basins appear to be
maintained as required?
Are perimeter control BMPs
maintained?
Is the entrance stabilized to
prevent tracking?
Have sediments been tracked
on to the street?
Are storm drain inlets
protected and maintained?
Have materials collected
around the storm drains?
Has sediment accumulated on
impervious surfaces?
Are dumpsters and trash
receptacles covered?
Has trash/debris accumulated
throughout the site?
Are stockpiles and spoils
protected from runoff?
Are all storage areas clean
and maintained?
Are spill kits provided onsite?
Are washout areas maintained
and protected?
Were spills/leaks observed
during the inspection?
Were there any discharges
during the inspection?
Is the SWPPP wall map up to
date and accurate?
Was the SWPPP or Erosion
Control Plan reviewed?
Are portable restrooms
properly positioned?
Do portable restrooms have
secondary containment?
Are BMPs stockpiled for
emergency deployment?
COMMENTS
Thursday, June 26, 2025
12/27/2021
05/25/2023
10/15/2024
37800
Inspection
Status
Owner: AVIARA LP
Subdivision: RANCHO AGUA HEDIONDA POR
OF
Address: 1205 AVIARA PKWY
CARLSBAD, CA 92011-1276
Primary Inspector Reinspection Inspection
Passed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Page 37 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
BLDG-13 Shear 235640-2024 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/08/2024 01/08/2024 BLDG-11 235819-2024 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 235818-2024 Partial Pass Tim Kersch Reinspectlon Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/09/2024 01/09/2024 BLDG-11 236049-2024 Passed Tim Kersch Complete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 236050-2024 Passed Tim Kersch Complete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/16/2024 01/10/2024 BLDG-11 236248-2024 Passed Tim Kersch Complete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 236249-2024 Passed Tim Kersch Complete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-SW-Inspection 236805-2024 Passed Tim Kersch Complete
Thursday, June 26, 2025 Page 36 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
BLDG-13 Shear 234008-2023 Passed Tim Kersch Complete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/19/2023 12/19/2023 BLDG-11 234157-2023 Passed Tim Kersch Complete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 234158-2023 Passed Tim Kersch Complete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/20/2023 12/20/2023 BLDG-11 234358-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 234360-2023 Partial Pass Tim Kersch Relnspectlon Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/03/2024 01/03/2024 BLDG-11 234548-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 234547-2023 Partial Pass Tim Kersch Reinspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/04/2024 01/04/2024 BLDG-11 235639-2024 Partial Pass Tim Kersch Relnspection Incomplete
Foundatlon/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 35 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHOAGUAHED~NDAPOR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
BLDG-13 Shear 233267-2023 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/13/2023 12/13/2023 BLDG-11 233435-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 233437-2023 Partial Pass Tim Kersch Relnspectlon Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/14/2023 12/14/2023 BLDG-11 233681-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 233682-2023 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/15/2023 12/15/2023 BLDG-11 233834-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundatlon/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 233835-2023 Partial Pass Tim Kersch Reinspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/18/2023 12/18/2023 BLDG-11 234007-2023 Passed Tim Kersch Complete
Foundatlon/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 34 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 232170-2023 Partial Pass Tim Kersch Reinspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/06/2023 12/06/2023 BLDG-11 232589-2023 Partial Pass Tim Kersch Relnspectlon Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 232590-2023 Partial Pass Tim Kersch Reinspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/07/2023 12/07/2023 BLDG-11 232809-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 232808-2023 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/11/2023 12/11/2023 BLDG-11 233038-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 233039-2023 Partial Pass Tim Kersch Reinspect ion Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/12/2023 12/12/2023 BLDG-11 233266-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 33 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/27/2023 11/27/2023 BLDG-11 231402-2023 Partial Pass Tim Kersch Reinspectlon Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/28/2023 11/28/2023 BLDG-11 231564-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/29/2023 11/29/2023 BLDG-11 231766-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/30/2023 11/30/2023 BLDG-11 231958-2023 Passed Tim Kersch Complete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 231959-2023 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/01/2023 12/01/2023 BLDG-11 232057-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 232058-2023 Partial Pass Tim Kersch Reinspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/04/2023 12/04/2023 BLDG-11 232169-2023 Partial Pass Tim Kersch Re inspection Incomplete
F oundation/Ftg/Piers
(Rebar)
Thursday, June 26, 2025 Page 32 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
Angie Teanio 949-615-0390 Jacob 06/28/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
11/16/2023 11/16/2023 BLDG-11 230686-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 230687-2023 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/17/2023 11/17/2023 BLDG-11 230866-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 230867-2023 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/20/2023 11/20/2023 BLDG-11 230972-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/21/2023 11/21/2023 BLDG-11 231146-2023 Passed Tim Kersch Complete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/22/2023 11/22/2023 BLDG-11 231296-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Thursday, June 26, 2025 Page 31 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
Angie Teanio 949-615-0390 Jacob 06/28/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
11/14/2023 11/09/2023 BLDG-11 230052-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 230258-2023 Partial Pass Tim Kersch Reinspectlon Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949•615-0390 Jacob 06/21/2023
Angie Teanio 949·615-0390 Jacob 06/26/2023
Angie Teanio 949·615-0390 Jacob 06/27/2023
Angie Teanio 949•615-0390 Jacob 06/28/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
11/15/2023 11/15/2023 BLDG-11 230591-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 230592-2023 Passed Tim Kersch Complete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 30 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio CMU 07/25/2023
BLDG-84 Rough 229701-2023 Passed Tim Kersch Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
11/08/2023 11/08/2023 BLDG-11 229894-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 229895-2023 Partial Pass Tim Kersch Re inspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
11/09/2023 11/09/2023 BLDG-13 Shear 230051-2023 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 29 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivisio n: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
10/30/2023 10/30/2023 BLDG-11 228709-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
10/31/2023 10/31/2023 BLDG-11 228948-2023 Partial Pass Tim Kersch Relnspectlon Incomplete
Foundation/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/01/2023 11/01/2023 BLDG-11 229087-2023 Partial Pass Tim Kersch Relnspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/02/2023 11/02/2023 BLDG-11 229259-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/06/2023 11/06/2023 BLDG-11 229432-2023 Passed Tim Kersch Complete
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLOG-84 Rough 229508-2023 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
11/07/2023 11/07/2023 BLDG-11 229700-2023 Passed Tim Kersch Complete
Foundatlon/Ftg/Piers
(Rebar)
Thursday, June 26, 2025 Page 28 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/23/2023 10/23/2023 BLDG-11 227953-2023 Partial Pass Tim Kersch Reinspectlon Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 227954-2023 Partial Pass Tim Kersch Reinspectlon Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/24/2023 10/24/2023 BLDG-11 228153-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
10/25/2023 10/25/2023 BLDG-11 228377-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
10/26/2023 10/26/2023 BLOG-11 228501-2023 Partial Pass Tim Kersch Relnspectlon Incomplete
Foundation/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 27 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
BLDG-84 Rough 227452-2023 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/19/2023 10/19/2023 BLDG-11 227655-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 227656-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/20/2023 10/20/2023 BLDG-11 227777-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 227778-2023 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Thursday, June 26, 2025 Page 26 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/12/2023 10/12/2023 BLDG-84 Rough 226805-2023 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/17/2023 10/17/2023 BLDG-11 227151-2023 Partial Pass Tim Kersch Reinspect Ion Incomplete
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 227150-2023 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/18/2023 10/18/2023 BLDG-11 227451-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 25 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLOG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/05/2023 10/05/2023 BLDG-11 226144-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 226145-2023 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/1 0/2023 10/10/2023 BLDG-11 226406-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
10/11/2023 10/11/2023 BLDG-11 226650-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 226651-2023 Partial Pass Tim Kersch Relnspection Incomplete
Combo(14,24,34,44)
Thursday, June 26, 2025 Page 24 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
BLDG-14 225298-2023 Partial Pass Tim Kersch Re inspection Incomplete
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
09/28/2023 09/28/2023 BLDG-11 225462-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
10/02/2023 10/02/2023 BLDG-84 Rough 225689-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/03/2023 10/03/2023 BLDG-84 Rough 225869-2023 Partial Pass Tim Kersch Relnspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/04/2023 10/04/2023 BLDG-11 225972-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 225971-2023 Partial Pass Tim Kersch Reinspectlon Incomplete
Combo{14,24,34,44)
Thursday, June 26, 2025 Page 23 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
09/20/2023 09/20/2023 BLDG-11 224510-2023 Passed Tim Kersch Complete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
09/26/2023 09/26/2023 BLDG-11 225007-2023 Partial Pass Tim Kersch Relnspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio CMU 07/25/2023
BLDG-13 Shear 225006-2023 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
Angie Teanio 949-615-0390 Jacob 06/28/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
09/27/2023 09/27/2023 BLDG-11 225299-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 22 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
BLDG-11 223438-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
09/12/2023 09/12/2023 BLDG-11 223660-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
09/13/2023 09/13/2023 BLDG-11 223819-2023 Passed Tim Kersch Complete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
09/18/2023 09/18/2023 BLDG-11 223974-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
09/19/2023 09/19/2023 BLDG-84 Rough 224410-2023 Partial Pass Tim Kersch Relnspectlon Incomplete
Combo(14,24,34,44)
Thursday, June 26, 2025 Page 21 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
09/07/2023 09/07/2023 BLDG-11 22307 4-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
BLDG-84 Rough 223075-2023 Partial Pass Tim Kersch Reinspect ion Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
09/08/2023 09/08/2023 BLDG-11 223324-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
09/11/2023 09/11/2023
Thursday, June 26, 2025 Page 20 of 44
Permit Type:
Work Class:
Status:
Scheduled
Date
PERMIT INSPECTION HISTORY for (CBC2021-0489)
BLDG-Commercial Application Date: 12/27/2021
New Issue Date: 05/25/2023
Closed -Finaled Expiration Date: 10/15/2024
IVR Number: 37800
Actual Inspection Type Inspection No. Inspection
Start Date Status
BLDG-11 222713-2023 Partial Pass
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
Angie Teanio
Angie Teanio
COMMENTS
TEXT
949-615-0390 Jacob
949-615-0390 Jacob
Jacob 949-615-0390
Owner: AVIARA LP
Subdivision: RANCHO AGUA HEDIONDA POR
OF
Address: 1205 AVIARA PKWY
CARLSBAD, CA 92011-1276
Primary Inspector Reinspection Inspection
Tim Kersch Re inspection Incomplete
Passed
Yes
Created Date
06/16/2023
06/26/2023
07/17/2023
BLDG-24 Rough/Topout 222711-2023 Partial Pass Tim Kersch Relnspection Incomplete
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-84 Rough
Combo(14,24,34,44)
222712-2023
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
COMMENTS
Passed
Yes
Passed Tim Kersch Complete
Passed
Yes
No
No
No
No
09/06/2023 09/06/2023 BLDG-11 222985-2023 Partial Pass Tim Kersch Reinspection Incomplete
Thursday, June 26, 2025
Foundation/Ftg/Piers
(Rebar)
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
Angie Teanio
Angie Teanio
COMMENTS
TEXT
949-615-0390 Jacob
949-615-0390 Jacob
Jacob 949-615-0390
BLDG-84 Rough
Combo(14,24,34,44)
222986-2023 Partial Pass Tim Kersch
Passed
Yes
Created Date
06/16/2023
06/26/2023
07/17/2023
Relnspectlon Incomplete
Page 19 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
08/30/2023 08/30/2023 BLOG-11 222474-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
BLOG-84 Rough 222475-2023 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
08/31/2023 08/31/2023 BLOG-84 Rough 222598-2023 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
09/01/2023 09/01/2023
Thursday, June 26, 2025 Page 18 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
BLDG-84 Rough 221943-2023 Partial Pass Tim Kersch Reinspect ion Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
08/28/2023 08/28/2023 BLDG-11 222138-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
BLDG-84 Rough 222139-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
08/29/2023 08/29/2023 BLDG-11 222240-2023 Partial Pass Tim Kersch Relnspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 222241-2023 Partial Pass Tim Kersch Relnspectlon Incomplete
Combo(14,24,34,44)
Thursday, June 26, 2025 Page 17 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
08/17/2023 08/17/2023 BLDG-11 220928-2023 Partial Pass Tim Kersch Relnspectlon Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
08/22/2023 08/22/2023 BLDG-11 221360-2023 Partial Pass Tim Kersch Relnspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
08/23/2023 08/23/2023 BLDG-43Air 221769-2023 Passed Tim Kersch Complete
Cond./Furnace Set
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 221768-2023 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
08/25/2023 08/25/2023 BLDG-43 Air 221944-2023 Partial Pass Tim Kersch Re inspection Incomplete
Cond./Furnace Set
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 16 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
Angie Teanio 949-615-0390 Jacob 06/28/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
BLDG-21 219905-2023 Partial Pass Tim Kersch Re inspection Incomplete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio Jacob 949-615-0390 07/17/2023
08/09/2023 08/09/2023 BLDG-11 220104-2023 Partlal Pass Tim Kersch Re Inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
08/10/2023 08/10/2023 BLDG-11 220246-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
08/15/2023 08/15/2023 BLDG-11 220593-2023 Partial Pass Tim Kersch Relnspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 15 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
BLDG-14 219284-2023 Partial Pass Tim Kersch Reinspectlon Incomplete
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
08/02/2023 08/02/2023 BLDG-66 Grout 219472-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
08/03/2023 08/03/2023 BLDG-11 219597-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Foundation/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio CMU 07/25/2023
BLDG-21 219598-2023 Partial Pass Tim Kersch Re inspection Incomplete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio Jacob 949-615-0390 07/17/2023
08/08/2023 08/08/2023 BLDG-13 Shear 219906-2023 Partial Pass Tim Kersch Reinspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 14 of 44
PERMIT INSPECTION HISTORY for {CBC2021-0489)
Permit Type: BLOG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/1 5/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
07/31/2023 07/31/2023 BLDG-11 219067-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
BLDG-13 Shear 219065-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
Angie Teanio 949-615-0390 Jacob 06/28/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
BLDG-14 219066-2023 Partial Pass Tim Kersch Re inspection Incomplete
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-21 219068-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio Jacob 949-615-0390 07/17/2023
08/01/2023 08/01/2023 BLDG-11 219285-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 13 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector
Date Start Date
NOTES Created By
Angie Teanio
Angie Teanio
Angie Teanio
Angie Teanio
Angie Teanio
Status
TEXT
949-615-0390 Jacob
949-615-0390 Jacob
949-615-0390 Jacob
949-615-0390 Jacob
Jacob 949-615-0390
BLDG-21
Underground/Underflo
or Plumbing
218700-2023 Partial Pass
Checklist Item COMMENTS
BLDG-Building Deficiency
Tim Kersch
07/27/2023 07/27/2023 BLDG-11 218854-2023 Partial Pass Tim Kersch
Thursday, June 26, 2025
Foundation/Ftg/Piers
(Rebar)
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
COMMENTS
TEXT
CMU
BLDG-13 Shear
Panels/HD (ok to wrap)
218853-2023 Partial Pass Tim Kersch
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
Angie Teanio
Angie Teanio
Angie Teanio
Angie Teanio
COMMENTS
TEXT
949-615-0390 Jacob
949-615-0390 Jacob
949-615-0390 Jacob
949-615-0390 Jacob
Jacob 949-615-0390
BLDG-21
Underground/Underflo
or Plumbing
218855-2023 Partial Pass Tim Kersch
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
COMMENTS
TEXT
Jacob 949-615-0390
Reinspection
Created Date
06/21/2023
06/26/2023
06/27/2023
06/28/2023
07/17/2023
Relnspection
Passed
Yes
Re inspection
Passed
Yes
Created Date
07/25/2023
Reinspection
Passed
Yes
Created Date
06/21/2023
06/26/2023
06/27/2023
06/28/2023
07/17/2023
Relnspection
Passed
Yes
Created Date
07/17/2023
Inspection
Incomplete
Incomplete
Incomplete
Incomplete
Page 12 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
BLDG-13 Shear 218109-2023 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
Angie Teanio 949-615-0390 Jacob 06/28/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
BLDG-21 218111-2023 Partial Pass Tim Kersch Reinspectlon Incomplete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio Jacob 949-615-0390 07/17/2023
07/25/2023 07/25/2023 BLDG-22 Sewer/Water 218498-2023 Partial Pass Tim Kersch Relnspectlon Incomplete
Service
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
07/26/2023 07/26/2023 BLDG-11 218699-2023 Partial Pass Tim Kersch Relnspectlon Incomplete
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio CMU 07/25/2023
BLDG-13 Shear 218698-2023 Partial Pass Tim Kersch Reinspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 11 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 9201 1-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
07/18/2023 07/18/2023 BLDG-11 217720-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
BLDG-13 Shear 217719-2023 Partial Pass Tim Kersch Relnspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
Angie Teanio 949-615-0390 Jacob 06/28/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
BLDG-21 217721-2023 Partial Pass Tim Kersch Reinspectlon Incomplete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio Jacob 949-615-0390 07/17/2023
07/20/2023 07/20/2023 BLDG-11 218110-2023 Partial Pass Tim Kersch Reinspectlon Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio Jacob 949-615-0390 07/17/2023
Thursday, June 26, 2025 Page 10 of 44
I
PERMIT INSPECTION HISTORY for {CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
07/11/2023 07/10/2023 BLDG-11 216699-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-12 Steel/Bond 216926-2023 Partial Pass Tim Kersch Relnspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-13 Shear 216927-2023 Partial Pass Tim Kersch Reinspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-21 216928-2023 Partial Pass Tim Kersch Re inspection Incomplete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
07/13/2023 07/13/2023 BLDG-13 Shear 217248-2023 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
Angie Teanio 949-615-0390 Jacob 06/28/2023
BLDG-21 217249-2023 Passed Tim Kersch Complete
Underground/Underflo
orPlumblng
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 9 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
BLDG-13 Shear 216257-2023 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
Angie Teanio 949-615-0390 Jacob 06/28/2023
07/06/2023 07/06/2023 BLDG-11 216364-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Foundatlon/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-21 216362-2023 Partial Pass Tim Kersch Re inspection Incomplete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
07/10/2023 07/10/2023 BLDG-13 Shear 216697-2023 Partial Pass Tim Kersch Reinspectlon Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
Angie Teanio 949-615-0390 Jacob 06/28/2023
BLDG-21 216698-2023 Partial Pass Tim Kersch Reinspection Incomplete
Underground/Underflo
or Plumbing
Thursday, June 26, 2025 Page 8 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Application Date: 12/27/2021 Owner: AVIARA LP Permit Type: BLDG-Commercial
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
Status: Closed -Finaled Expiration Date: 10/15/2024
IVR Number: 37800
OF
Address: 1205 AVIARA PKWY
CARLSBAD, CA 92011-1 276
Scheduled Actual Inspection Type
Date Start Date
Inspection No. Inspection Primary Inspector Reinspection Inspection
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
Angie Teanio
Angie Teanio
Angie Teanio
Status
COMMENTS
TEXT
949-615-0390 Jacob
949-615-0390 Jacob
949-615-0390 Jacob
949-615-0390 Jacob
BLDG-12 Steel/Bond
Beam
216116-2023 Passed
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
Angie Teanio
Angie Teanio
Angie Teanio
Angie Teanio
Angie Teanio
Angie Teanio
COMMENTS
TEXT
949-615-0390 Jacob
949-615-0390 Jacob
949-615-0390 Jacob
949-615-0390 Jacob
949-615-0390 Jacob
949-615-0390 Jacob
949-615-0390 Jacob
BLDG-21
Underground/Underflo
or Plumbing
216118-2023 Passed
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
Angie Teanio
Angie Teanio
Angie Teanio
COMMENTS
Waster main service.
TEXT
949-615-0390 Jacob
949-615-0390 Jacob
949-615-0390 Jacob
949-615-0390 Jacob
Tim Kersch
Tim Kersch
07/05/2023 07/05/2023 BLDG-11 216258-2023 Partial Pass Tim Kersch
Thursday, June 26, 2025
Foundation/Ftg/Piers
(Rebar)
Checklist Item
BLDG-Building Deficiency
COMMENTS
Passed
Yes
Created Date
06/13/2023
06/15/2023
06/20/2023
06/27/2023
Complete
Passed
Yes
Created Date
06/06/2023
06/15/2023
06/19/2023
06/21/2023
06/26/2023
06/27/2023
06/28/2023
Complete
Passed
Yes
Created Date
06/21/2023
06/26/2023
06/27/2023
06/28/2023
Re inspection Incomplete
Passed
Yes
Page 7 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
BLDG-12 Steel/Bond 215913-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/06/2023
Angie Teanio 949-615-0390 Jacob 06/15/2023
Angie Teanio 949-615-0390 Jacob 06/19/2023
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
Angie Teanio 949-615-0390 Jacob 06/28/2023
BLDG-13 Shear 215914-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
Angie Teanio 949-615-0390 Jacob 06/28/2023
BLDG-21 215915-2023 Partial Pass Tim Kersch Relnspectlon Incomplete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Waster main service. Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
Angie Teanio 949-615-0390 Jacob 06/28/2023
06/30/2023 06/30/2023 BLDG-11 216117-2023 Passed Tim Kersch Complete
Foundation/Ftg/Piers
(Rebar)
Thursday, June 26, 2025 Page 6 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 9201 1-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/13/2023
Angie Teanio 949-615-0390 Jacob 06/15/2023
Angie Teanio 949-615-0390 Jacob 06/20/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
BLDG-12 Steel/Bond 215722-2023 Partial Pass Tim Kersch Reinspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/06/2023
Angie Teanio 949-615-0390 Jacob 06/15/2023
Angie Teanio 949-615-0390 Jacob 06/19/2023
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
BLDG-13 Shear 215724-2023 Partial Pass Tim Kersch Relnspectlon Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
BLDG-21 215725-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Waster main service. Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
Angie Teanio 949-615-0390 Jacob 06/27/2023
06/29/2023 06/29/2023
Thursday, June 26, 2025 Page 5 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
BLDG-12 Steel/Bond 215472-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/06/2023
Angie Teanio 949-615-0390 Jacob 06/15/2023
Angie Teanio 949-615-0390 Jacob 06/19/2023
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
BLDG-13 Shear 215473-2023 Partial Pass Tim Kersch Re inspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
BLDG-21 215474-2023 Partial Pass Tim Kersch Reinspection Incomplete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Waster main service. Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
Angie Teanio 949-615-0390 Jacob 06/26/2023
06/28/2023 06/28/2023 BLDG-11 215723-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 4 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date: 10/15/2024 Address: 1205 AVIARA PKWY
IVR Number: 37800 CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
BLDG-12 Steel/Bond 214933-2023 Partial Pass Tim Kersch Reinspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/06/2023
Angie Teanio 949-615-0390 Jacob 06/15/2023
Angie Teanio 949-615-0390 Jacob 06/19/2023
06/22/2023 06/22/2023 BLDG-12 Steel/Bond 215093-2023 Partial Pass Tim Kersch Reinspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/06/2023
Angie Teanio 949-615-0390 Jacob 06/1512023
Angie Teanio 949-615-0390 Jacob 0611912023
Angie Teanio 949-615-0390 Jacob 06/21/2023
BLDG-13 Shear 215094-2023 Partial Pass Tim Kersch Reinspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
BLDG-21 215095-2023 Partial Pass Tim Kersch Reinspection Incomplete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/21/2023
06/27/2023 06/2712023 BLDG-11 215475-2023 Partial Pass Tim Kersch Re Inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Thursday, June 26, 2025 Page 3 of 44
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Application Date: 12/27/2021 Owner: AVIARA LP Permit Type: BLDG-Commercial
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
Status: Closed -Finaled Expiration Date: 10/15/2024
IVR Number: 37800
OF
Address: 1205 AVIARA PKWY
CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/06/2023
Angie Teanio 949-615-0390 Jacob 06/15/2023
06/19/2023 06/19/2023 BLDG-11 214630-2023 Partial Pass Tim Kersch Reinspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
BLDG-12 Steel/Bond 214631-2023 Partial Pass Tim Kersch Reinspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/16/2023
06/20/2023 06/20/2023 BLDG-12 Steel/Bond 214743-2023 Partial Pass Tim Kersch Reinspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/06/2023
Angie Teanio 949-615-0390 Jacob 06/15/2023
Angie Teanio 949-615-0390 Jacob 06/19/2023
06/21/2023 06/21/2023 BLDG-11 214934-2023 Partial Pass Tim Kersch Re inspection Incomplete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 949-615-0390 Jacob 06/13/2023
Angie Teanio 949-615-0390 Jacob 06/15/2023
Angie Teanio 949-615-0390 Jacob 06/20/2023
Thursday, June 26, 2025 Page 2 of 44
Building Permit Inspection History Finaled
{cityof
Carlsbad
PERMIT INSPECTION HISTORY for (CBC2021-0489)
Permit Type: BLDG-Commercial Application Date: 12/27/2021 Owner: AVIARA LP
Work Class: New Issue Date: 05/25/2023 Subdivision: RANCHO AGUA HEDIONDA POR
OF
Status: Closed -Finaled Expiration Date:
IVR Number:
10/15/2024
37800
Address: 1205 AVIARA PKWY
CARLSBAD, CA 92011-1276
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date
BLDG-84 Rough 245636-2024
Combo(14,24,34,44)
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
COMMENTS
Status
Requested Tim Kersch
06/07/2023 06/07/2023 BLDG-12 Steel/Bond 213360-2023 Partial Pass Tim Kersch
Beam
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
COMMENTS
TEXT
949-615-0390 Jacob
06/14/2023 06/14/2023 BLDG-11 214086-2023 Partial Pass Tim Kersch
Foundation/Ftg/Piers
(Rebar)
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
COMMENTS
TEXT
949-615-0390 Jacob
06/16/2023 06/16/2023 BLDG-11 214427-2023 Partial Pass Tim Kersch
Thursday, June 26, 2025
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
Angie Teanio
COMMENTS
TEXT
949-615-0390 Jacob
949-615-0390 Jacob
BLDG-12 Steel/Bond
Beam
214426-2023 Partial Pass Tim Kersch
Incomplete
Passed
Yes
Yes
No
No
No
Reinspection Incomplete
Passed
Yes
Created Date
06/06/2023
Relnspection Incomplete
Passed
Yes
Created Date
06/13/2023
Re inspection Incomplete
Passed
Yes
Created Date
06/13/2023
06/15/2023
Reinspection Incomplete
Page 1 of 44
.. •
l N TER W ESi
DA TE: JUNE 28, 2022
JURISDICTION: CITY OF CARLSBAD
PLAN CHECK#.: CB-CBC2021-0489.RC2
PROJECT ADDRESS: 1205 Aviara Parkway
□ APPLICANT
□ JURIS.
sE_ylf( lV
PROJECT NAME: AVIARA APARTMENTS PARKING STRUCTURE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies id entified below are resolved and checked by building department staff.
IZI The check list transmitted herewith is for the applicant's information. The plans are being held
at lnterwest until corrected plans are submitted for recheck. SEE ATTACHED FOR
REMAJNING ITEMS
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
IZI The applicant's copy of the check list has been sent to the jurisdiction at:
Warmers Properties
D lnterwest staff did not advise the applicant that the plan check has been completed.
IZI lnterwest staff did advise the applicant that the plan check has been completed.
Person contacted: Warmers Properties Telephone#: 858-623-4941
Date contacted: (by:
Mail Telephone Fax In Person
0 REMARKS:
By: ALI SADRE S.E., CASp (for D.Y.)
lnterwest
6/17
Email: robertog@wermersprooerties.com
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 921 23 ♦ (858) 560-1468 ♦ Fax. (858) 560-1 576
City of Carlsbad CB-CBC2021-0489 .RC 1
APR. 15,2022
GENERAL
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one
of two ways:
1. Deliver all corrected sets of plans and ca lculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-
2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering
and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and ca lculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City
Planning, Engineering and Fire Departments until review by lnterwest is complete.
ACCESSIBILITY
Please show the access aisle on the passenger side of the van accessible parking for
single van accessible stall, with the vehicle in the forward position. See detail 2/GA 1 .4,
bottom of the page. Sec. 1109A.8.6.
ADDITIONAL
3. Please provide a response list indicating where each correction item has been
addressed on the plans. I.e., specify the plan sheet, note, or detail number, calculation
page, etc., where the item is corrected on the plans.
4. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake Drive, Suite
208, San Diego, California 92123; telephone number of 858/560-1468, to perform the
plan review for your project. If you have any questions regarding these plan review
items, please contact ALI SADRE S.E., CASp (for D.Y.) at lnterwest. Thank you.
• 1W
IN TER W E S T
A SAF!lbullt COMPANY
DATE: 4/20/22
JURISDICTION: Carlsbad
PLAN CHECK#.: CB-PC2021-0065.RC1
PROJECT ADDRESS: 1205 Aviara Parkway
□ APPLICANT
□ JURIS.
SET: II
PROJECT NAME: Aviara Apartments -259 Unit Multifamily wrap building
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes .
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
C8J The check list transmitted herewith is for the applicant's information. The plans are being held at
lnterwest until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to the jurisdiction.
D lnterwest staff did not advise the applicant that the plan check has been completed.
C8J lnterwest staff did advise the applicant that the plan check has been completed.
Person contacted: Wermers Properties Telephone#: 858-623-4941
Date contacted: (by: ) Email: robertog@wermersproperties.com
Mail Telephone Fax In Person
0 REMARKS:
By: Paul Martinez, AIA, NCARB
lnterwest
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, Cali fornia 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
NOTE: The items listed below are from the previous correction list. These remaining items
have not been adequately addressed. The numbers of the items are from the previous check
list and may not necessarily be in sequence. The notes in bold font are current.
GENERAL
1. Please make all corrections, as requested in the correction list. Submit FOUR new complete
sets of plans for commercial/industrial projects (THREE sets of plans for residential projects).
For expeditious processing, corrected sets can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad
Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will
route the plans to lnterwest and the Carlsbad Planning, Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320 Chesapeake
Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and
calculations/reports directly to the City of Carlsbad Building Department for routing to their
Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City
Planning, Engineering and Fire Departments until review by lnterwest is complete.
2. Plans may be submitted in electronic format, subject to the jurisdiction's approval. If so, they
must have restrictions removed from the security settings. Electronic plans with restrictions to
markups, printing, or stamping will not be approved.
Electronic plans must be submitted back to the jurisdiction's building department and will then
be routed to lnterwest. ONLY submit FULL complete and combined sets of plans, uploading
multiple single sheets will not be allowed. Make sure all plans and calc packages, spec.
reports, etc. are labeled clearly and can be read what they are and WHAT SUBMITTAL they
go with. DO NOT SEND documents directly to lnterwest as they will not be accepted.
3. Provide item-by-item responses on an 8-1/2-inch by 11-inch sheet(s) clearly and specifically
indicating where and how each correction item has been addressed (vague responses, such
as "Done" or "See plans," are unacceptable).
4. Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located in the plans. Have changes been made to the plans not resulting from
this correction list?
Please indicate: □Yes □ No
5. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake Drive, Suite 208,
San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review
for your project. If you have any questions regarding these plan review items, please contact
lnterwest. Thank you.
STRUCTURAL
Plan Check Engineer: Erich A. Kuchar, P.E.
1. No further comments as submitted.
ELECTRICAL
Set: II
PLAN REVIEWER: Scott Humphrey SET:11
1) No Comments.
MECHANICAL & PLUMBING COMMENTS
PLAN REVIEWER: Martha McNicholas, P.E. SET II
MECHANICAL (2019 CALIFORNIA MECHANICAL CODE)
2nd Review 4-15-2022
Previous comments not addressed:
1. (Title 24 not provided). Area provided on Energy Cale's Title 24 section A, reflected the total
area for entire building. Each AC equipment should be sized based on each unit square
footage /zone area and by the building occupancy type. Please provide energy calculations for
each unit to match area on architectural plans and the (2) proposed sizes equipment
scheduled KBtu/hr. Energy Title 24 showed on section H. Dry System Equipment indicated 2
systems 23 KBtu/hr and 29 KBtu/hr, equipment schedule is undersized to 17 Kbtu/hr and 21
Kbtu/hr respectively. Please provide the correct equipment schedule to comply with Title 24,
Part 6 or Energy Code and 2019 California Green Building Code, Title 24 Part II. After
corrected , a complete mechanical plan review will be performed.
2. (Title 24 not provided) No sizing calculations were provided. Please provide load
calculations, sizing, system type and equipment selection for each proposed AC equipment
schedule KBtu/hr. CEC 140.4(a) and (b). Envelope heating and cooling loads shall be
calculated using envelope characteristics, including square footage, thermal conductance,
Solar Heat Gain Coefficient or shading coefficient, and air leakage, consistent with the
proposed design. CEC 140(b) 5
3. Missing mechanical plans M-4.0, M-4.1, M-4.2 for leasing office/gym/fitness. Please provide
NOTE: Additional comments may follow upon addressing this item.
4. (Title 24 not provided) For leasing office/gym/fitness, please provide energy calculations for
each unit to match area on architectural plans to comply with Title 24, Part 6 or Energy Code
and 2019 California Green Building Code, Title 24 Part II. After corrected , a complete
mechanical plan review will be performed.
5. (Title 24 not provided) For leasing office/gym/fitness Please provide load calculations, sizing,
system type and equipment selection for each proposed AC. CEC 140.4(a) and (b). Envelope
heating and cooling loads shall be calculated using envelope characteristics, including square
footage, thermal conductance, Solar Heat Gain Coefficient or shading coefficient, and air
leakage, consistent with the proposed design. CEC 140(b) 5
6. No provided. Please provide note on plans that a louver door will be installed .. Clothes
dryers installed in enclosed spaces require an opening of not less than 100 square inches for
make-up air within the door or by other approved means. Please address on the plans. CMC
504.4.1
7. location. NOTE: If so, the ducts cannot terminate within that enclosed location.
Additional comments after items are addressed:
8. Plan M1 .0. Table with air handler equipment schedule indicated fan coils schedule. Table with
fan coils equipment schedule, indicated air handler schedule. Please correct equipment
schedule on tables.
9. Plan M4.0. 1st and 2nf floor. Provide room names on plans.
10. Plan M4.0. Provide ventilation to bathroom on 1st floor area. Only exhaust is provided. Heating,
Ventilation and air conditioning Systems (including hydronic systems) shall be balanced
Please provide ventilation according with Table 402.1 CMC 402.1. Per CMC 314.1
11 . Plan M4 .0. Please show compliance with CMC 603.4.1 & 603.5 for length limitations for
factory made flexible air ducts: (1) Cannot be greater than 5' in length, (2) cannot be used as a
replacement of rigid elbows (i.e. only an elbow connect to a terminal device/register is
acceptable), (3) sag between supports hangers shall not exceed ½" per foot of support
spacing, and (4) the elbow connection to the terminal device/register is required to have a
bend radius not less than one duct diameter. Provide rigid duct work installation details on
plans.
PLUMBING (2019 CALIFORNIA PLUMBING CODE)
12. No provided. Carlsbad Only: Per City of Carlsbad, new buildings are required to comply with
the Carlsbad Climate Action Plan. Regarding the water heating design, please either provide a
heat pump water heater, electric resistance water heater or solar water-heating system.
13. No provided. Please review the required CAP form. Either electrical or solar powered water
heaters are required. Please address. NOTE: A complete review of the gas sizing calculations
will be conducted upon addressing this comment.
14. No provided. No civil/site plans were provided. Provide civil/site plumbing plans showing the
locations of the gas and water meters, the site gas and water supply piping and the pipe sizing,
cleanouts, routes, and slopes for both the sewer and storm drainage systems.
15. No provided. Identify the extent of the private sewer, water, and gas systems on the
plumbing site plan. Clearly specify, on the plans, which City Department (i.e. Building
Department, Engineering Department etc.) is responsible for the permitting, plan check, and
inspections for the private utility systems. NOTE: If this will be under a separate permit, please
specify this within the plans.
16. No provided. If the Building Department is responsible for the review of the private (civil) site
utility systems, then provide complete on-site plumbing construction drawings for the private
site water system and private site sewer and storm waste systems. CPC Chapter 7, Part 2
17. No provided. For backwater valve review, please show the upstream sewer manhole rim and
finished floor elevations per CPC 710.0. Mandatory: Fixtures installed on a floor level below
the next upstream manhole cover require backwater protection. NOTE: Please see the
following requirements.
• MANDATORY: Fixtures installed on a floor level below the next upstream manhole
cover require backwater protection.
• PROHIBITED: Fixtures installed on a floor level above the next upstream manhole
cove~ cannot drain through a backwater valve.
18. No provided. All multi-residential buildings now require water sub-meters for each unit.
Please show this within the enlarged water plans. CPC 601.2.
19. Title 24 not provided. Energy Cale's Title 24 indicated 259 solar water heaters. Equipment
schedule indicated (9) gas water heaters. Please clarify
20. To be provided. A blank Certification of Compliance were provided on plans. A complete
certificate of compliance is necessary when installing CPVC/PEX water piping materials prior
to building permit issuance. CPC 604.1.1 (CPVC)/CPC 604.1.2(PEX) NOTE: Please provide.
Note: If you have any questions regarding this Plumbing and Mechanical plan review, please contact
Martha McNicholas mmcnicholas@esgil.com. To speed the review process, note on this list (or a
copy) where the corrected items have been addressed on the plans.
BUILDING COMMENTS
Plan Reviewer: Paul Martinez, AIA Set: II
PLANS
1. All sheets of the plans and the first sheet of the calculations are required to be signed by the
licensed architect or engineer responsible for the plan preparation. California Business and
Professions Code.
RC-1: Drawings cannot be approved until plans and first sheet of calculations are
signed by the architect or engineer responsible for their preparation.
FIREWALLS
2. Fire walls shall extend to the outer edge of horizontal projecting elements, such as balconies,
roof overhangs, canopies, marquees and architectural projections that are within 4' of the fire
wall. Section 706.5.2. Exceptions:
a) Horizontal projecting elements without concealed spaces, provided the exterior wall
behind and below the projecting element has not less than 1-hour fire-resistance-rated
construction for a distance not less than the depth of the projecting element on both
sides of the fire wall. Openings within such exterior walls shall be protected by fire
assemblies having a fire-protection rating of not less than¾ hour.
b) Noncombustible horizontal projecting elements with concealed spaces, provided a
minimum 1-hour fire-resistance-rated wall extends through the concealed space. The
projecting element shall be separated from the building by a minimum of 1-hour fire-
resistance-rated construction for a distance on each side of the fire wall equal to the
depth of the projecting element. The wall is not required to extend under the projecting
element where the building exterior wall is not less than 1-hour fire-resistance-rated for
a distance on each side of the fire wall equal to the depth of the projecting element.
Openings within such exterior walls shall be protected by fire assemblies having a fire-
protection rating of not less than ¾ hour.
c) For combustible horizontal projecting elements with concealed spaces, the fire wall
need only extend through the concealed space to the outer edges of the projecting
elements. The exterior wall behind and below the projecting element shall be of not
less than 1-hour fire-resistance-rated construction for a distance not less than the depth
of the projecting elements on both sides of the fire wall. Openings within such exterior
walls shall be protected by fire assemblies having a fire-protection rating of not less than
¾ hour.
RC-1: Details to prove compliance were not provided for the projections (i.e.,
balconies). Please provide.
3. Where the roof on either side of a fire wall slopes toward the fire wall at a slope greater than
2: 12, the fire wall shall extend to a height equal to the height of the roof located 4' from the fire
wall plus 30 inches. Section 706.6.2. There is no exception to this requirement (i.e., the
exceptions found in Section 706.6 do not apply here).
RC-1: Details to prove compliance were not provided. Please contact the plan reviewer
to coordinate alternate means of compliance.
FIRE-RESISTIVE CONSTRUCTION
4. Please indicate the basis of approval (Item Number in Table 721.1 , U.L. Directory, etc.) for the
fire-resistive construction elements found in the AD series drawings. Details missing basis of
approval include 11/AD1 .2, 15/AD1 .2, etc.
RC-1: Please provide a basis of approval for the lined joist bays within the floor/ceiling
and roof/ceiling assemblies.
5. Detail how fire-resistive wall construction will be maintained at built-in wall fixtures and behind
mailboxes, fire extinguisher cabinets, electric panels exceeding 16 square inches in area, etc.
Section 714.4.2. See detail 19/AD1 .2, etc., and provide basis of approval.
RC-1: A basis of approval is required for the outlet penetration detail. Please provide.
ROOFS/DECKS/BALCONIES
6. Specify on the plans the following information for the deck/balcony surfacing materials, per
CBC Section 107.2:
a) Manufacturer's name and product name/number.
b) ICC approval number, or equal.
RC-1: Information was not provided. The comment will stand until the information is
provided.
ADDITIONAL ITEMS FOR R2 OCCUPANCIES
7. Wall and floor/ceiling assemblies separating dwelling units from each other and from common
space (such as corridors, laundry rooms, common garages, service areas, etc.) must have a
listed rating of STC 50 (and IIC of 50 for floors). Section 1206. Show the location of and
provide details of the listed wall and floor/ceiling assemblies and indicate the listing agency and
listing number for the tested ratings.
RC-1: The corridor wall does not meet the minimum STC level required by code. Please
revise.
ACCESSIBLE ROUTE OF TRAVEL
8. Accessible routes of travel shall be provided from public transportation stops, accessible
parking and accessible passenger loading zones, and public streets or sidewalks to the
accessible entrance they serve. The accessible route shall to the extent feasible, coincide with
the route for the general public. Section 111 0A.1.
RC-1: Curb ramps are not provided when the walks abut the roads at the perimeter of
the development. Please also clarify if a bus stop serves the development. If so, please
provide an accessible path of travel from the bus stop.
[DO NOT PAY -THIS IS NOT AN INVOICE}
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Paul Martinez
BUILDING ADDRESS: Aviara Parkway
BUILDING OCCUPANCY: R-2, B, A-3
BUILDING AREA Valuation
PORTION ( Sq. Ft.} Multiplier
R-2 239391
B 4039
A-3 4028
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
1997 UBC Building Permit Fee ~]
I <'\-1,\1'1 .
1997 UBC Plan Check Fee • J
Type of Review: Complete Review
D Repetitive Fee
..,. Repeats
D Other
D Hour1y
EsGil Fee
PLAN CHECK#.: CB-PC2021-0065
DATE: 01-20-2022
Reg. VALUE ($}
Mod.
43,092,405
43,092,405
D Structural Only
$27,004.55
Sheet 1 of 1
DA TE: O 1-20-2022
JURISDICTION: Carlsbad
PLAN CHECK#.: CB-PC2021-0065
PROJECT ADDRESS: Aviara Parkway
• 1W
INTERWEST
A SAF'Ebuitt COMPANY
□ APPLICANT
□ JURIS.
SET: I
PROJECT NAME: Aviara Apartments -259 Unit Multifamily wrap building
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
[8J The check list transmitted herewith is for the applicant's information. The plans are being held at
lnterwest until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
[8J The applicant's copy of the check list has been sent to the jurisdiction.
D lnterwest staff did not advise the applicant that the plan check has been completed.
[8J lnterwest staff did advise the applicant that the plan check has been completed.
Person contacted: Wermers Properties Telephone#: 858-623-4941
Date contacted: (by: ) Email: robertog@wermersproperties.com
Mail Telephone
0 REMARKS:
By: Paul Martinez
lnterwest
Fax In Person
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
PLAN REVIEW CORRECTION LIST
COMMERCIAL
PLAN CHECK#.: CB-PC2O21-OO65
OCCUPANCY: R-2, B, A-3
TYPE OF CONSTRUCTION : V-A
JURISDICTION: Carlsbad
USE: Mixed Use Apartment Building
ACTUAL AREA: R-2-239,391 / A -4,028
B -4,039
Building using height and area increase STORIES: 4
For sprinkler as allowed in footnotes and this
Being an R-2 building on grade HEIGHT: under 60'-0"
SPRINKLERS?: Yes
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: -
DATE INITIAL PLAN REVIEW
COMPLETED: 01-20-2022
FOREWORD (PLEASE READ):
OCCUPANT LOAD: -
DATE PLANS RECEIVED BY
ESGIL CORPORATION: -
PLAN REVIEWER: Paul Martinez
This plan review is limited to the technical requirements contained in the California version of
the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy conservation , noise attenuation and access for
the disabled. This plan review is based on regulations enforced by the Building Department.
You may have other corrections based on laws and ordinances enforced by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Code sections cited are based on the 2019 CBC, which adopts the 2018 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2018 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
GENERAL
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to lnterwest and the Carlsbad Planning ,
Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by lnterwest is
complete.
2. Plans may be submitted in electronic format, subject to the jurisdiction's
approval. If so, they must have restrictions removed from the security settings.
Electronic plans with restrictions to markups, printing, or stamping will not be
approved.
3.
4.
5.
Electronic plans must be submitted back to the jurisdiction's building department
and will then be routed to lnterwest. ONLY submit FULL complete and combined
sets of plans, uploading multiple single sheets will not be allowed. Make sure all
plans and calc packages, spec. reports, etc. are labeled clearly and can be read
what they are and WHAT SUBMITTAL they go with. DO NOT SEND documents
directly to lnterwest as they will not be accepted.
Provide item-by-item responses on an 8-1/2-inch by 11-inch sheet(s) clearly and
specifically indicating where and how each correction item has been addressed
(vague responses, such as "Done" or "See plans," are unacceptable).
Please provide a response list indicating where each correction item has been
addressed on the plans. I.e., specify the plan sheet, note, or detail number,
calculation page, etc., where the item is corrected on the plans.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans. Have changes been
made to the plans not resulting from this correction list?
Please indicate: □Yes □ No
6. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact lnterwest. Thank
you.
7. All sheets of the plans and the first sheet of the calculations are required to be
signed by the licensed architect or engineer responsible for the plan preparation.
California Business and Professions Code.
STRUCTURAL
Plan Check Engineer: Erich A. Kuchar, P.E. Set: I
8. Provide a finalized stamped and signed Geotechnical Engineering Report. The
one provided indicates this was a draft and not final. If any values have changed,
please indicate them and structural to be updated to match.
9. Provide a letter from the soils engineer confirming that the foundation plan,
grading plan and specifications have been reviewed and that it has been
determined that the recommendations in the soil report are properly incorporated
into the plans.
10. Add "Post Tension Drawings" to deferred submittal list on sheet SN1 .
11 . Update title on 3/SW0.2 for "4" story building not "5".
12. Concrete Mix for foundations to specify Exposure Category C1 at a minimum.
Footings are in contact with soil and therefore exposed to minimal moisture.
Exposure Category C1 can be removed if waterproofing protection is placed
between the foundation and the soil. ACI 318-14, Table 19.3.1.1 . I.e.
13. Provide an anchor detail for Truss Roof Framing as well. Only flat frame details
on sheet SW9.0 were provided however the roof is truss assembly.
14. For DJ add to plans for table call outs what the minimum depth to be left after
ripping and match with calcs ... for 2x8 which is 7 .. 5" thick what can they be
ripped to for the lengths provided ... 6", 5.5" ... ?
15. Provide elevations for all Moment Frames uses on plans and shown in tables for
MF-1 through MF-9. Currently only MF-1 and MF-2 elevations are provided .
16. Call out the structural seismic gap required between the apartment building and
the stand-alone parking garage building. Furthermore, the separation must be a
minimum of square root of the sum of the squares for the deflection of the 2
buildings. Due to two separate engineering firms working on each building each
set of plans must note what is the maximum deflection in each direction on each
floor level to guarantee coordination has been done and separation can be
verified. Please add.
17. On sheet S7.1.5 for the detail call out bubble at Drive Through Tunnel #2 this is
labeled as 1/S3.25 yet there is no S3.25 sheet please update.
18. For the tunnel area above as mentioned where the steel moment frame is
located there is a shear wall that is being supported on this beam. Provide calc
reference for where this beam is located showing the seismic tension.
Compression load is being applied with the 2.5x amplifier for discontinuous shear
walls along with all roof, floor, and wall framing loading.
19. Seismic-force-resisting Systems
a) Combination of systems along the same axes. Where a combination of
different structural systems is used in the same direction, the value of R
used in each direction should not be greater than the least R of the
systems in that direction. (ASCE 7-16, Section 12.2.3). For where the
moment frames are in parallel with the wood framed shear walls show in
the calculations where this has been done or update plans and calcs.
20. Where trellises are located in the corner of the buildings the EBM anchors must
be attached to the deck framing at level 4 as they can not be on the roof and then
over the trellises. Provide a detail how they will eb anchored into the deck
framing of these units similar to details on sheet SW9.0. How does the concrete
decking work? How will anchors be attached?
21 . Provide some sort of blocking and strapping at floor framing of moment frame to
wood frame interaction at second floor framing for tunnel areas. This will be a
weak point in the diaphragm due to moment frame deflection greater than wood
walls .... Some sort of strapping is required to ensure the top of the moment
frame does not move independently away from the sheathing and top chords of
the wood walls.
22. Detail 4/SW5.0 calls out for Hoist Beam per plan yet Hoist Beam could not be
found on plan please add and update.
ELECTRICAL
PLAN REVIEWER: Scott Humphrey SET: I
1) Sheet E0.10, E0.11 , E0.12 -Feeders to the individual units is not identified -
Reference is made to sheet E0.18 which does not exist. Additionally, the unit
PNL & APT# are missing. Please add all information to the plan set.
2) Sheet E0.10 -The feeder from HSDA (225A) to emergency inverter is not
identified. I did see the voltage drop calculations where its identified however,
should be referenced for the inspector.
3) Sheet E0.10 -Feeders from PNL EG1 to the other emergency PNL's is not
identified. Please add to the plan set.
4) Sheet E0.10 -The fire pump controller shall have a listed SPD installed in or on
the controller, 695.15 CEC.
5) Sheet E0.11 -Not all feeders are identified on the plans. Example, 1 000A feeder
to MSB to MSB-3R is not identified . I did see the voltage drop calculations where
its identified however, should be referenced for the inspector. Please check all
and add feeder tags.
6) E0.14 -All Services equipment rated 1200amps or more provide the following
information on a permanent label, 110.16(8):
a) Nominal system voltage
b) Available fault current at the service OCPD
c) Clearing time of the service OCPD
d) Date the calculation was performed
(i) A note on the plans is fine.
7) E0.16 -Please update the general notes to the 2019 Title 24 -currently
references to the 2016 cycle. Update all pages.
8) E0.10 -All emergency switchboards and PNL boards shall have a listed SPD
installed in or on the equipment, 700.8 CEC .
9) E3.21 -No electrical shown.
10) E3.22 -No electrical shown.
11) E3.23 -No electrical shown.
12) Please add the future PV system to the deferred submittal page.
13) Sheets E0.31 and E1 .5 are missing from the plan set.
14) Sheet E0.32 is not referenced (listed) on the index page, E0.01.
15) Details regarding site (area) lighting/power were not provided for review and
were not part of this review.
Note: If you have any questions regarding this Electrical and Energy plan review list
please contact Scott Humphrey at (858) 560-1468. To speed the review process, note
on this list (or a copy) where the corrected items have been addressed on the plans.
MECHANICAL & PLUMBING COMMENTS
PLAN REVIEWER: Martha McNicholas, P.E. SET
MECHANICAL (2019 CALIFORNIA MECHANICAL CODE)
1. Area provided on Energy Cale's Title 24 section A, reflected the total area for
entire building. Each AC equipment should be sized based on each unit square
footage /zone area and by the building occupancy type. Please provide energy
calculations for each unit to match area on architectural plans and the (2)
proposed sizes equipment scheduled KBtu/hr. Energy Title 24 showed on section
H. Dry System Equipment indicated 2 systems 23 KBtu/hr and 29 KBtu/hr,
equipment schedule is undersized to 17 Kbtu/hr and 21 Kbtu/hr respectively.
Please provide the correct equipment schedule to comply with Title 24, Part 6 or
Energy Code and 2019 California Green Building Code, Title 24 Part II. After
corrected, a complete mechanical plan review will be performed.
2. No sizing calculations were provided. Please provide load calculations, sizing,
system type and equipment selection for each proposed AC equipment schedule
KBtu/hr. CEC 140.4(a) and (b). Envelope heating and cooling loads shall be
calculated using envelope characteristics, including square footage, thermal
conductance, Solar Heat Gain Coefficient or shading coefficient, and air leakage,
consistent with the proposed design. CEC 140(b) 5
3. Missing mechanical plans M-4.0, M-4.1 , M-4.2 for leasing office/gym/fitness.
Please provide NOTE: Additional comments may follow upon addressing this
item.
4. For leasing office/gym/fitness, please provide energy calculations for each unit to
match area on architectural plans to comply with Title 24, Part 6 or Energy Code
and 2019 California Green Building Code, Title 24 Part II. After corrected , a
complete mechanical plan review will be performed.
5. For leasing office/gym/fitness Please provide load calculations, sizing, system
type and equipment selection for each proposed AC. CEC 140.4(a) and (b).
Envelope heating and cooling loads shall be calculated using envelope
characteristics, including square footage, thermal conductance, Solar Heat Gain
Coefficient or shading coefficient, and air leakage, consistent with the proposed
design. CEC 140(b) 5
6. Provide total quantity of FAU's and CU 's on proposed equipment schedule
7. Please provide on architectural and mechanical plans fire rated walls for all shaft
locations penetrating walls for CEF/1 corridor ventilation on hallways as per detail
A/M2.1 to comply with CBC 713
8. For the propose fire damper/smoke, fire smoke dampers shall comply with UL
555S, and shall be installed in accordance with the manufacturer's installation
instructions where required by the California Building Code. Please provide UL
listed and installation details on plans. CMC 605.1
9. Fire and smoke dampers shall be provided with an approved means of access
large enough to allow inspection and maintenance of the damper and its
operating parts. The access shall not affect the integrity of the fire-resistance-
rated assembly. The access openings shall not reduce the fire-resistance rating
of the assembly. CMC 605.5
10. For CEF/1 , provide enlarge plan for corridor ventilation showing duct termination
location on corridors.
11. Exhaust outlets shall be located a minimum of 10 feet (3048 mm) above
adjoining grade and 10 feet (3048 mm) from doors, occupied areas, and
operable windows. CMC 407.2.2
12. Mounting details for FAU 1 & 2. Please provide fan coils details installation on
plans showing condensate overflow protection details on plans. Where an
equipment or appliance is installed in a space where damage can result from
condensate overflow, other than damage to replaceable lay-in ceiling tiles, a
drain line shall be provided and shall be drained in accordance with Section
310.1. An additional protection method for condensate overflow shall be provided
in accordance with one of the following:
• A water level detecting device that will shut off the equipment or appliance
in the event the primary drain is blocked. CMC 310.2
• An additional watertight pan of corrosion-resistant material, with a
separate drain line, installed beneath the cooling coil, unit, or the
appliance to catch the overflow condensate due to a clogged primary
condensate drain.
13. For each new unit, please provide outdoor air calculations showing the minimum
outside air rates will be provided. Please provide calculations for each unit upon
next submittal (i.e. Qwhole = 0.03Afloor + 7.5(Nbed +1 )). Per California Energy
Code 120.1(c).3 (i.e. see Table 120.1-A)
14. Please provide O/A ductwork location, routing, and termination on plans to all fan
coils units. CEC 120
15. Outdoor air intakes shall be located at least 25 feet from exhaust outlets of
ventilating systems, combustion equipment stacks, and areas that may collect
vehicular exhaust or other noxious fumes. The bottom of outdoor air intakes shall
be located a s high as practicable, but not less than 10 feet above ground level. If
installed above the roof, they shall be located 18 inches above roof level or 3 feet
above a flat roof where heavy snowfall is anticipated. Please provide location on
plans. CMC407.2.1
16. Clearly specify within the mechanical plans that a duct leakage test will be
conducted that complies with CMC 603.10.1
17. Provide the dryer manufacturers installation instructions. If using the
manufacturers installation instructions, please provide the dryer manufacturers
model number to be on the plans. CMC 504.4
18. Clothes dryers installed in enclosed spaces require an opening of not less than
100 square inches for make-up air within the door or by other approved means.
Please address on the plans. CMC 504.4.1
19. Plans showed some units exhaust termination on balconies or directly into
openings. Environmental air duct exhaust shall terminate not less than 3 feet
from a property line, 10 feet from a forced air inlet, and 3 feet from openings into
the building. Environmental exhaust ducts shall not discharge onto a public
walkway. Please correct on plans location of exhaust ducts. CMC 502.2.1
20. Some units showed VTR on exhaust dryers/bathrooms. Provide Vent thru roof
riser plan showing ceiling/floors/roof penetrations, fire rated assemblies, and
protection provided on each penetration. Piping, tubing, and duct system
penetrations of fire-resistance-rated walls, partitions, floors, floor/ceiling
assemblies, roof/ceiling assemblies, or shaft enclosures shall be protected in
accordance with the requirements of the California Building Code CBC 714 and
CMC 316.5
21 . Elevator machine rooms are required to have independent ventilation or an
independent air conditioning system to protect against overheating. Please
provide enlarge elevator room on plans and AC system . CBC 3005.2
22. Please address the location where Units range hood exhaust ducts terminate.
Clearly specify within the plans if there is a breezeway directly above this
location. NOTE: If so, the ducts cannot terminate within that enclosed location.
PLUMBING (2019 CALIFORNIA PLUMBING CODE)
23. Carlsbad Only: Per City of Carlsbad, new buildings are required to comply with
the Carlsbad Climate Action Plan. Regarding the water heating design, please
either provide a heat pump water heater, electric resistance water heater or solar
water-heating system.
24. Please review the required CAP form. Either electrical or solar powered water
heaters are required. Please address. NOTE: A complete review of the gas
sizing calculations will be conducted upon addressing this comment.
25. No civil/site plans were provided. Provide civil/site plumbing plans showing the
locations of the gas and water meters, the site gas and water supply piping and
the pipe sizing , cleanouts, routes , and slopes for both the sewer and storm
drainage systems.
26. Identify the extent of the private sewer, water, and gas systems on the plumbing
site plan. Clearly specify, on the plans, which City Department (i.e. Building
Department, Engineering Department etc.) is responsible for the permitting, plan
check, and inspections for the private utility systems. NOTE: If this will be under
a separate permit, please specify this within the plans.
27 . If the Building Department is responsible for the review of the private (civil) site
utility systems, then provide complete on-site plumbing construction drawings for
the private site water system and private site sewer and storm waste systems.
CPC Chapter 7, Part 2
28. For backwater valve review, please show the upstream sewer manhole rim and
finished floor elevations per CPC 710.0. Mandatory: Fixtures installed on a floor
level below the next upstream manhole cover require backwater protection.
NOTE: Please see the following requirements.
• MANDATORY: Fixtures installed on a floor level below the next upstream
manhole cover require backwater protection.
• PROHIBITED: Fixtures installed on a floor level above the next upstream
manhole cover cannot drain through a backwater valve.
29. All multi-residential buildings now require water sub-meters for each unit. Please
show th is within the enlarged water plans. CPC 601 .2.
30. Please provide on plans water-conserving Fixtures and Fittings as per Note 1:
[BSC, DSA-SS & DSA-SS/CC] Flow rates for specified plumbing fixtures for
mandatory nonresidential construction are contained in Chapter 5, Division 5.3 of
the California Green Building Standards Code (Part 11 , Title 24, California Code
of Regulations -CALGreen). Scoping provisions applicable to nonresidential
additions and alterations are contained in Section 301.3 of CALGreen. CPC
401 .3 Please make sure the maximum flow rate for each fixture complies with the
following chart:
FIXTURE TYPE MAXIMUM FLOW RATE
Water closets 1.28 gallons/flush
Urinals (wall mounted) 0. 125 gallons/flush
Showers 1.8 gpm @ 80 psi
Lavatory faucets-nonresidential 0. 5 gpm @60 psi
Kitchen faucets 1.8 gpm @ 60 psi
Metering faucets 0. 2 gallons/cycle
31 . Energy Cale's Title 24 indicated 259 solar water heaters. Equipment schedule
indicated (9) gas water heaters. Please clarify
32. Provide hot water heater calculations on plans. The minimum capacity for
storage water heaters shall be in accordance with the first-hour rating listed in
Table 501 .1 (2).
33. Water heaters of other than the direct-vent type shall be located as close as
practical to the chimney or gas vent. Please provide on plan . CPC 504.2
34. Waters heaters are located on roof. Please provide the clearance requirements
for water heaters. Shall comply with Section CPC 504.3.1 or Section CPC
504 .3.2.
35. Detail 6 on plan P0.2 for water heating venting does not apply to this project.
Water heaters are proposed on roof per plan P2.5. Clarify.
36. For the hot water recirculating loop system, please detail the following:
• The installation of an air release valve on the inlet side of the recirculation
pump, within 4' of the pump.
• Show the required hose bibb installed between the water heater and isolation
valve (after the recirculation pump) per Energy Code 110.3.(c).5.C
37. 2" Vent on fixture schedule is indicated. Some 1 1 /2" vents are shown on riser
plan P4.0. Please correct.
38. Please provide floors numbers on riser plans P4.0/ P4.1
39. Provide Vent thru roof riser plan showing ceiling/floors/roof penetrations, fire
rated assemblies, and protection provided on each penetration. Piping, tubing,
and duct system penetrations of fire-resistance-rated walls, partitions, floors,
floor/ceiling assemblies, roof/ceiling assemblies, or shaft enclosures shall be
protected in accordance with the requirements of the California Building Code
CBC 714
40. For each gas meter, please provide a gas line rise isometric and calculations
showing gas demands, pipe total developed lengths (i.e. for MPG & low
pressure), the proper CPC 1215.2 Tables (i.e. for MPG & low pressure) and pipe
sizing. NOTE: A complete review of the gas sizing will be conducted upon
addressing this comment.
41 . For each gas pressure regulator, please show the following requirements within
the plumbing floor plans: (1) An accessible shut-off valve installed prior to the
regulator and (2) vented to the exterior. CPC 1208. 7 .5(1) & 1210.9
42. Within each floor plan (i.e. water supply and waste & vent), please provide ID
tags for each fixture that is consistent within the fixture schedule. NOTE: 'TYP.
notes will suffice, yet each floor plan needs at least some fixture ID tags).
43. Please add the following note to the plumbing plans: "Per CPC 309.5, the
plumbing piping system will be designed and installed in conformance with sound
limitations as required in CBC."
44. In areas of residential accommodation drainage piping material (i.e. waste, vent
and storm drainage) types ABS and PVC are limited to buildings of two stories or
less. All buildings that have 3 or more levels of residential units cannot use PVC
or ABS. Please address. CPC 701 .2(a), CPC 903.1.1, & CPC 1101.4
45. A blank Certification of Compliance were provided on plans. A complete
certificate of compliance is necessary when installing CPVC/PEX water piping
materials prior to building permit issuance. CPC 604.1.1 (CPVC)/CPC
604.1.2(PEX) NOTE: Please provide.
46. Describe the method of compliance for temperature limitations for the following
fixture types: bathtubs, bidets, and showers 120 degrees F per CPC 408.3,
409.4. NOTE: The water heater thermostat may not be used for compliance.
47. A mop/service sink is specified within the fixture schedule. No locations were
provided on plans.
48. Please provide plumbing roof plans showing the location of all plumbing vent
terminations in relation to the solar ready areas. NOTE: Plumbing vents cannot
terminate directly below PV panels.
49. Include the main and overflow roof drainage design calculations: Roof area,
rainfall rate, pipe sizing, horizontal drain slope and drain, gutters and
downspout's locations on the plans. CPC 1103.0.
Note: If you have any questions regarding this Plumbing and Mechanical plan review,
please contact Martha McNicholas mmcnicholas@esgil.com. To speed the review
process, note on this list (or a copy) where the corrected items have been addressed on
the plans.
BUILDING COMMENTS
Plan Reviewer: Paul Martinez, AIA Set: I
PLANS
1. All sheets of the plans and the first sheet of the calculations are required to be
signed by the licensed architect or engineer responsible for the plan preparation.
California Business and Professions Code.
2. Provide a note on the plans indicating if any hazardous materials will be stored
and/or used within the building which exceed the quantities listed in IBC Tables
307.1(1) and 307.1(2).
3. Specify on the plans the uses of all rooms or areas. Sec. 107.2.
4. On the cover sheet of the plans, include smoke alarm as deferred submittal item
(CBC 420.5).
SITE PLAN
5. Provide a statement on the site plan stating: "All property lines, easements and
buildings, existing and proposed, are shown on this site plan." Additional
verbiage such as " ... must be verified with civil plans" is not acceptable. Drawings
shall be coordinated upon submittal. Please ensure drawings are coordinated
and remove verbiage such as "must be verified with [discipline]" from future
submittals.
6. Show on the site plan all proposed walls, retaining walls and fences. Specify their
heights on the plans. Provide construction details if a part of this permit.
7. Show on the site plan , or provide the grading plans, showing finish floor
elevations, elevations of finish grade adjacent to buildings, drainage patterns and
locations and gradients of cut or fill slopes. Section 107.2.
8. Show the location of any designated flood plains , open space easements, or
other development restricted areas on the site plan. Section 107.2.
BUILDING AREA
9. FLS analysis sheet A 1.2 is incomplete or uncoordinated. Examples:
a) All areas: mixed-use allow area e_guation is not found on CBC 506.2.4 as
cited in the calculations
b) Area 2 is a mixed-use building (contains S-2), but is not designated as
mixed-use
c) Area 5 cites 508.2.3 for the allowable area calculation, but that is not the
correct code section
d) Fire wall legend stipulates the building is Type Ill-A, but the coversheet
stipulates the building is Type V-A.
e) Fire protection between dwelling units is required but not shown on the
plans (CBC 420.2)
f) Fire protection between occupancies is required but not shown on the
plans (CBC 508.4)
FIREWALLS
10. Per Section 706.2, a fire wall shall have sufficient structural stability under fire
conditions to allow collapse of construction on either side without collapse of the
wall or shall be constructed as double fire walls in accordance with NFPA 221.
11 . Fire walls shall be continuous from exterior wall to exterior wall and shall extend
at least 18" beyond the exterior surface of exterior walls. Section 706.5.
Exceptions:
a) Fire walls shall be permitted to terminate at the interior surface of
combustible exterior sheathing or siding provided the exterior wall has a
fire-resistance rating of at least 1 hour for a horizontal distance of at least
4' on both sides of the fire wall. Openings within such exterior walls shall
be protected by fire assemblies having a fire-protection rating of not less
than¾ hour.
b) Fire walls shall be permitted to terminate at the interior surface of
noncombustible exterior sheathing, exterior siding or other
noncombustible exterior finishes provided the sheathing, siding, or other
exterior noncombustible finish extends a horizontal distance of at least 4'
on both sides of the fire wall.
c) Fire walls shall be permitted to terminate at the interior surface of
noncombustible exterior sheathing where the building on each side of the
fire wall is protected by an automatic sprinkler system.
12. Where the fire wall intersects exterior walls, the fire-resistance rating of the
exterior walls shall comply with one of the following, per Section 706.5.1 :
a) The exterior walls on both sides of the fire wall shall have a 1-hour fire-
resistance rating with ¾-hour protection where opening protection is
required by Section 705.8. The fire-resistance rating of the exterior wall
shall extend a minimum of 4 feet on each side of the intersection of the fire
wall to exterior wall. Exterior wall intersections at fire walls that form an
angle equal to or greater than 180 degrees do not need exterior wall
protection.
b) Buildings or spaces on both sides of the intersecting fire wall shall assume
to have an imaginary lot line at the fire wall and extending beyond the
exterior of the fire wall. The location of the assumed line in relation to the
exterior walls and the fire wall shall be such that the exterior wall and
opening protection meet the requirements set forth in Sections 705.5 and
705.8. Such protection is not required for exterior walls terminating at fire
walls that form an angle equal to or greater than 180 degrees.
13. Fire walls shall extend to the outer edge of horizontal projecting elements, such
as balconies, roof overhangs, canopies, marquees and architectural projections
that are within 4' of the fire wall. Section 706.5.2. Exceptions:
a) Horizontal projecting elements without concealed spaces, provided the
exterior wall behind and below the projecting element has not less than 1-
hour fire-resistance-rated construction for a distance not less than the
depth of the projecting element on both sides of the fire wall. Openings
within such exterior walls shall be protected by fire assemblies having a
fire-protection rating of not less than ¾ hour.
b) Noncombustible horizontal projecting elements with concealed spaces,
provided a minimum 1-hour fire-resistance-rated wall extends through the
concealed space. The projecting element shall be separated from the
building by a minimum of 1-hour fire-resistance-rated construction for a
distance on each side of the fire wall equal to the depth of the projecting
element. The wall is not required to extend under the projecting element
where the building exterior wall is not less than 1-hour fire-resistance-
rated for a distance on each side of the fire wall equal to the depth of the
projecting element. Openings within such exterior walls shall be protected
by fire assemblies having a fire-protection rating of not less than ¾ hour.
c) For combustible horizontal projecting elements with concealed spaces, the
fire wall need only extend through the concealed space to the outer edges
of the projecting elements. The exterior wall behind and below the
projecting element shall be of not less than 1-hour fire-resistance-rated
construction for a distance not less than the depth of the projecting
elements on both sides of the fire wall. Openings within such exterior
walls shall be protected by fire assemblies having a fire-protection rating
of not less than¾ hour.
14. Where the roof on either side of a fire wall slopes toward the fire wall at a slope
greater than 2: 12, the fire wall shall extend to a height equal to the height of the
roof located 4' from the fire wall plus 30 inches. Section 706.6.2.
a) There is no exception to this requirement (i.e., the exceptions found in
Section 706.6 do not apply here).
FIRE-RESISTIVE CONSTRUCTION
15. Please indicate the basis of approval (Item Number in Table 721.1, U.L.
Directory, etc.) for the fire-resistive construction elements found in the AD series
drawings. Details missing basis of approval include 11 /AD1 .2, 15/AD1 .2, etc.
16. Details with references to the 2016 code cycle include 1/AD1 .2, 4/AD1 .2,
5/AD1 .2, 8/AD1 .2, etc. Please revisit FLS details and include current code cycle
references .
17. Please key FLS details to the plans. Some details do not appear to be related to
the project. For instance, there are details for 2-hr protection, but Table 602
stipulates a maximum rating of 1 Hr for various building elements.
18. Provide details on the plans for the fire-resistive construction. Include roof/ceiling
assemblies, floor/ceiling assemblies, wall assemblies, column, and beam
assemblies, etc. Be sure to list with each detail the basis of approval (U .L. listing
number, ICC research report, etc.).
a) In California, Section 705.5 was modified for Group A, E, H, I, Land R
occupancies, along with high-rise buildings, by requiring exterior walls to
be rated for exposure to fire from both sides, regardless of fire separation
distance.
b) There are 2 Hr protection details shown on the AD series sheets, but
Table 602 stipulates the highest rating is 1 Hr for Type VA. Please
coordinate fire protection details accordingly.
c) There are details that are not keyed to the plans. Please key in plans,
sections, etc., as necessary.
19. Detail how fire-resistive wall construction will be maintained at built-in wall
fixtures and behind mailboxes, fire extinguisher cabinets, electric panels
exceeding 16 square inches in area, etc. Section 714.4.2. See detail 19/AD1 .2,
etc., and provide basis of approval.
20. Detail on the plans how fire-resistive wall and ceiling protection will be
maintained at all duct penetrations, such as at bathroom and kitchen hood fans,
laundry room fans and dryer vents. Section 717. See also details 11/AD1 .2,
15/Ad1 .2.
21 . Fire dampers shall be installed per Section 717.5 at all duct and air transfer
openings of:
a) Ceilings of fire-resistive floor-ceiling assemblies or roof-ceiling assemblies.
b) Fire walls.
c) Fire barriers (see exception for walls).
d) Fire partitions at fire-rated corridors. See exceptions.
e) Shaft enclosures (smoke dampers are also required). See exceptions.
22. Smoke dampers shall be installed per Section 717.5 at all duct and air transfer
openings of:
a) Fire-rated corridors.
b) Shaft enclosures (fire dampers are also required). See exceptions.
c) Horizontal exits.
d) Smoke barriers.
e) In California, Section 717.5.2 was modified for Group A, E, H, I, Land R
occupancies, along with high-rise buildings, to state that duct openings in
fire barriers shall also be provided with smoke dampers.
23. If smoke dampers are required , the plans shall show the locations of the smoke
detectors listed in the options of Section 717.3.3.2 of the CBC.
24. Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor--
ceilings and roof-ceilings shall be protected as required in CBC Section 714."
25. Clearly identify location and hourly fire-resistive rating of vertical shafts on the
plans. Provide construction details showing location of fire dampers and how fire
resistivity will be maintained at floors and roofs. There are currently mechanical
shafts in the corridor that are not rated. Section 712.
26. An elevator machinery room is required to be separated from the remainder of
the building by fire barriers (707) and horizontal assemblies (711) that are not
less than the required rating of the hoistway. Please detail how these ratings will
be maintained for the mechanical openings shown. Note: This comment does
not apply to buildings 4 stories or less above grade plane and the machinery
room does not abut the elevator hoistway. Section 3005.
27. Where columns require a fire-resistance rating, the entire column , including its
connections to beams or girders, shall be protected. Where the column extends
through a ceiling, fire resistance of the column shall be continuous from the top of
the floor through the ceiling space to the top of the column. Please key detail to
plans. Section 704.2.
28. Members of the structural frame (other than columns) supporting more than one
floor and roof (or more than 2 floors, or supporting a load-bearing wall, or a
nonload-bearing wall more than 2 stories high) must be individually encasement
fire protected. (Section 704.3) Detail the required protection on the plans.
29. Detail all furred ceilings as required in Section 803.15.2.1.
30. Refer to detail 2/AD1 .6. Please confirm if it is the architect's intention to provide
unequal leafs, as shown in the detail. If so, ensure minimum clear widths are
maintained.
INTERIOR WALL AND CEILING FINISHES
31 . Provide a note on the plans or on the finish schedule, stating, "Wall and ceiling
materials shall not exceed the flame spread classifications in IBC Table 803.13."
FIRE BARRIERS
32. Structural members supporting a horizontal fire barrier must have the same fire-
resistive rating as the separation. Section 707.5.1.
33. Incidental use areas must be separated from the main occupancy. Section 509.
See Table 509 below. Please graphically show on the plans, similar to fire walls.
Please address the following specific concerns:
a) Even if sprinklers are used to eliminate the need for 1-hour wall
construction, Section 509.4.2 still requires the partitions to extend to the
underside of the floor/roof above and for any doors in the partitions to be
self-closing.
ROOM OR AREA SEPARATION AND/OR
PROTECTION
Furnace room where any piece of equipment 1 hour or provide automatic fire-
is over 400,000 Btu per hour input extinguishing system
Rooms with boilers where the 1 hour or provide automatic fire-
largest piece of equipment is extinguishing system
over 15 psi and 10 horsepower
Refrigerant machinery rooms 1 hour or provide automatic sprinkler
system
Laundry rooms over 100 square feet 1 hour or provide automatic fire-
extinguishing system
In other than ambulatory care facilities and 1 hour or provide automatic fire-
Group 1-2 occupancies, waste and linen extinguishing system
collection rooms over 100 square feet
34. Steel electrical outlet boxes at fire barrier walls shall not exceed sixteen square
inches, shall not exceed 100 square inches per 100 square feet of wall, and shall
be separated by a horizontal distance of twenty-four inches when on opposite
sides of a wall. Section 714.4.2.
35. Ducts penetrating fire barriers at occupancy separations must have fire dampers.
Section 717.5.2.
a) In California, Section 717.5.2 was modified for Group A, E, H, I, Land R
occupancies, along with high-rise buildings, to require smoke dampers in
addition to fire dampers.
36. Exits should have a minimum separation of one-half the maximum overall
diagonal dimension of the building or area served. Section 1007.1 .1. Where a
building is equipped throughout with an automatic sprinkler system , the
separation distance may be reduced to one-third of the diagonal. Please show
analysis on FLS plan .
37. Note on the plans: "All egress doors shall be readily openable from the egress
side without the use of a key or special knowledge or effort." Section 1010.1 .9.
In lieu of the above, in a Group B, F, Mor S occupancies (or places of religious
assembly or Group A occupancies having an occupant load of 300 or less), you
may note on the plans "Provide a sign on or near the exit door, reading THIS
DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED." This
signage is only allowed at the main exit. Section 1010.1.9.4.
38. Each door in a means of egress from an occupancy of Group A having an
occupant load of 50 or more (and any occupancy of Group H) shall not be
provided with a latch or lock unless it is panic hardware. Section 1010.1.10.
39. All doors and gates, within the exit path to a public way from an occupancy of
Group A having an occupant load of 50 or more (and any occupancy of Group H)
shall not be provided with latches or locks unless they are equipped with panic
hardware. Sections 1010.1.10 and 1010.2.
40. Regardless of occupant load, a floor or landing not more than ½ inch below the
threshold is required on each side of an egress door. Section 1010.1.7.
41 . Assembly occupancies must comply with Section 1029.
a) In California, Section 1029.3.1 was added to state: "Group A occupancies
that have an occupant load of 100 or more and less than 300, shall have
at least one of the required means of egress directly to an exit, or through
a lobby, that is not used to access the other required exit, to an exit, or to
a one hour rated corridor to an exit or continuous through a one hour rated
lobby to an exit."
STAIRWAYS
42. Stairway handrails should not project more than 4½ inches into the required
width. Section 1014.8.
43. Stairway riser must be 4 inches minimum and 7 inches maximum and minimum
run shall be 11 inches. Section 1011.5.2:
44. Doors opening onto a landing shall not reduce the landing to less than one-half
the required width. When fully open, the door shall not project more than 7" into
a landing. Section 1011.6.
45. The plans should clearly label the stairs as being either "interior exit access
stairways" (Section 1019) or "interior exit stairways" (Section 1023).
CORRIDORS
46. Corridors shall have fire partition walls of one-hour construction when required by
Table 1020.1. Show the locations of the rated corridors on the plans or clearly
show compliance with an applicable exception from Section 1020.1.
47. Corridors shall have interior door openings protected by tight-fitting smoke and
draft control assemblies rated 20 minutes. Table 716.1 (2). Doors shall be
maintained self-closing or be automatic closing by action of a smoke detector per
Section 909.5.3. Doors shall be gasketed to provide a smoke and draft seal
where the door meets the stop on sides and top. Section 716.2.2.1.
48. Duct penetrations (or air transfer openings) of fire-rated corridor construction
shall have fire and smoke dampers per Sections 717.
49. Provide a complete architectural section of the corridor, showing all fire-resistive
materials and details of construction for the fire partition walls and roof/ceilings
and all penetrations. Section 107.2.
EXIT SIGNS/ILLUMINATION
50. Exit signs are req uired whenever two exits are required. Show all required exit
sign locations on FLS plans. Section 1013.1.
51. Show that the means of egress path will be lighted with at least one-foot candle
at floor level. Section 1008.
52. Show separate sources of power may be required for exit illumination. Review
Section 1008.3.
ELEVATORS
53. In buildings having an elevator in California, at least one gurney-sized elevator
shall be provided. The elevator car shall be of such a size and arrangement to
accommodate a 24-inch by 84-inch ambulance gurney or stretcher with not less
than 5-inch radius corners in the horizo ntal open position and two emergency
personnel each requiring a minimum clear 21-inch diameter circle area. Section
3002.4.1 a.Please identify the gurney elevator on the plans and add clearances.
54. In California, Chapter 30 was modified for Group A, E, H, I, Land R occupancies,
along with high-rise buildings, to require elevator lobbies where an elevator shaft
connects more than TWO stories (as opposed to three stories listed in the IBC).
Note: The exception to eliminate the lobby due to fire sprinklers does not apply
to these occupancies.
55. Emergency Hoistway Venting. Elevator hoistways containing the driving machine
shall be provided with means for venting smoke and hot gasses to the outer air in
case of fires. Please show venting conformance with Section 3003.4
GLASS AND GLAZING
56 . Specify on the window schedule the glass type and thickness to show
compliance with Section 2404.
ROOFS/DECKS/BALCONIES
57. Enclosed framing in wood exterior balconies and decks shall be provided with
openings that provide a net free cross ventilation area not less than 1 /150 of the
area of each separate space. CBC Section 2304.12.2.6.
58. Wood balconies and decks that support moisture-permeable floors shall be
provided with an impervious moisture barrier system under the moisture-
permeable floor, with positive drainage. CBC Section 2304.12.2.5.
59 . Specify on the plans the following information for the deck/ balcony surfacing
materials, per Section 107.2:
a) Manufacturer's name and product name/number.
b) ICC approval number, or equal.
60. Specify on the plans the following information for the roof materials, per Section
1506.3:
a) Manufacturer's name and product name/number.
b) ICC approval number, or equal.
61 . Show the sizes/locations of roof/deck drains and overflows. Section 1503.4.
FIRE EXTINGUISHING
62. If standpipes are required, provide the following note on the plans: "In buildings
required to have standpipes, not less than one standpipe shall be provided for
use during construction. Standpipes shall be reviewed and approved prior to
installation." Section 3311 .
63. Specify on the plans that portable fire extinguishers will be installed in the
building in accordance with Section 906.
MISCELLANEOUS LIFE/SAFETY
64. Where columns are required to be fire-resistance rated by any provisions of the
code, the entire column shall be provided individual encasement protection on all
sides for the full column length. Please key details to the plans. Section 704.2.
65. Specify on plan all Primary Structural Members requiring individual fire
protection. This includes all columns and beams supporting more than two
stories or one story and the roof. Details for individual fire protection for these
members must be cut on plan and show an approved method for fire protection.
66. Please provide notes on the plans to show the suspended ceilings in Seismic
Design Categories D, E & F comply with ASCE 7-16 Section 13.5.6.2.2 as
follows:
a. The width of the perimeter supporting closure angle or channel shall be
not less than 2.0 in. unless qualified perimeter supporting clips are used.
b. Closure angles or channels shall be screwed or otherwise positively
attached to wall studs or other supporting structures. Perimeter supporting
clips shall be qualified in accordance with approved test criteria per
Section 13.2.5.
c. Perimeter supporting clips shall be attached to supporting closure angle or
channel with a minimum of two screws per clip and shall be installed
around the entire ceiling perimeter.
d. In each orthogonal horizontal direction, one end of the ceiling grid shall be
attached to the closure angle, channel, or perimeter supporting clip. The
other end of the ceiling gird in each horizontal direction shall have a
minimum 0.75-in clearance from the wall and shall rest upon and be free
to slide on a closure angle, channel, or perimeter supporting clip.
e. Ceiling areas over 2500 ft.2 must have seismic separation joints or full
height partitions.
f. Ceilings without rigid bracing must have 2" oversize trim rings for
sprinklers and other ceiling penetrations.
67. Specify on the plans that the draftstopping and fireblocking from Section 718 will
be installed (combustible construction):
a) Draftstopping in floors. Draftstopping shall be installed to subdivide floor
ceiling assemblies where required by Section 708.4.2. In other than
Group R occupancies, draft stopping shall be installed to subdivide
combustible floor/ceiling assemblies so that horizontal floor areas do not
exceed 1,000 square feet.
b) Draftstopping in attics. Draftstopping shall be installed to subdivide attic
spaces where required by Section 708.4.2. In other than Group R,
draftstopping shall be installed to subdivide combustible attic spaces and
combustible concealed roof spaces such that any horizontal area does not
exceed 3,000 square feet. Ventilation of concealed roof spaces shall be
maintained in accordance with Section 1202.2.1.
68. In R-2, where window openings are > 72" above grade, then the lowest part of
the window opening shall be at least 36" above the floor. Section 1015.8. See
possible exceptions.
69. "Group A occupancies that have an occupant load of 100 or more and less than
300, shall have at least one of the required means of egress directly to an exit, or
through a lobby, that is not used to access the other required exit, to an exit, or to
a one hour rated corridor to an exit or continuous through a one hour rated lobby
to an exit." Confirm assembly spaces comply.
70. Specify on the plans that the Emergency Responder Safety Features of
Section 914 will be installed .
ADDITIONAL ITEMS FOR R2 OCCUPANCIES
71 . Walls and floors separating dwelling units in the same building, shall be fire
partitions or horizontal assemblies as required by Sections 708 and 711 .
Sections 420.2 and 420.3:
a) Such fire partitions and floors shall have a fire-resistance rating of not less
than 1-hour (except in buildings of Type 118, 1118 and VB Construction with
automatic sprinkler systems (complying with Section 903.3.1.1), where the
fire-resistance rating may be reduced to ½-hour). Section 708.3.
b) Such fire partitions shall extend to the underside of the floor/roof sheathing
above.
i) In lieu of extending the wall to the floor/roof sheathing above, they
may terminate at the fire-resistance-rated roof/ceiling assembly
above. In this case, the space between the ceiling and the deck
above shall be fire-blocked or draftstopped in accordance with
Sections 718.2 and 718.3 at the partition line. Section 708.4.
72. For laundry and/or trash chutes, show on the plan compliance with Sections
713.13 and 903.2.11 .2.
73. Wall and floor/ceiling assemblies separating dwelling units from each other and
from common space (such as corridors, laundry rooms, common garages, service
areas, etc.) must have a listed rating of STC 50 (and IIC of 50 for floors). Section
1206. Show the location of and provide details of the listed wall and floor/ceiling
assemblies and indicate the listing agency and listing number for the tested
ratings.
74. Show that ceiling height hallways is a minimum of 7'-6". Section 1207.2.
75. Bathrooms (defined as having a shower or tub), shall be provided with
mechanical ventilation (an openable window is not allowed). Energy Standards
150(0).
76. Fans installed in bathrooms (having a shower or tub)-shall be Energy Star rated,
vented to the outside, and shall be controlled by a humidistat. (Humidistat not
required if the fan is a whole house ventilation component). CalGreen 4.506.1.
77. Show locations of permanently wired smoke alarms with battery backup in Group
R-2 occupancies as follows (Section 907.2.11 .2):
a) Inside each bedroom.
b) On the ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.
c) In each story within a dwelling unit, including basements.
• NOTE: Where more than one smoke alarm is required to be installed within a
unit, the smoke alarms shall be interconnected in such a manner that the
activation of one alarm will activate all of the alarms in the unit. Section
907.2.11.3.
78. In R-2, occupancies, where window openings are > 72" above grade, then the
lowest part of the window opening shall be at least 36" above the floor. Section
1015.8. See possible exceptions.
79. Indicate on the plans whether the sprinkler system is the residential type (13-R).
If so, exceptions to, or reductions in code requirements allowed because of the
installation of an automatic fire-extinguishing system are NOT permitted. For
example, Table 506.2 allows area increases only if the sprinkler system complies
with Section 903.3.1.1 (not 903.3. 1.2, which is the 13-R section). Also, the
allowable opening areas in Table 705.8 are based on non-13-R sprinklers.
ACCESSIBLE MEANS OF EGRESS CBC Section (1009)
80. All required accessible spaces shall be provided with accessible means of
egress equal in number to the number of exits required by Sections 1006.2 and
1006.3. CBC Section 1009.1.
a) Elevators. Sections 1009.2.1 and 1009.4:
i) In buildings 4 or more stories, elevators must comply with Section
1009.4 (which includes the need for standby power, etc.).
ii) In buildings less than 5 stories, designers have the option whether
elevators are to be considered part of the accessible means of
egress (to limit travel distance or to satisfy other provisions of the
code). If this option is taken, compliance with Section 1009.4 must
be shown.
ELEVA TORS AND WHEELCHAIR LIFTS
81. Specify on the plans that a two-way communication system shall be provided at
the elevator landings on each accessible floor. Section 1009.8. This applies
whether or not the building has an automatic fire sprinkler system.
82. Show on the plans to show that the inside of the elevator car complies with the
following, per Section 11 B-407.4.1. The clear distances between walls, or between
the walls and the door, excluding return panels, is:
a) :2'.68" by 54" (at side-slide opening doors).
i) In California, Section 3002.4A was modified for Group A, E, H, I, L
and R occupancies, along with high-rise buildings, to require an
elevator sized to accommodate the loading and transport of an
ambulance gurney with dimensions of 84 inches by 24 inches with
not less than 5-inch radius corners in the horizontal open position
and two emergency personnel each requiring a minimum clear 21 -
inch diameter circle area.
b) The distance from walls to front return panel is :2'.51".
83. All buildings and structures with one or more passenger service elevators shall be
provided with not less than one medical emergency service elevator to all landings
meeting the provisions of Section 3002.4a. The medical emergency service
elevator(s) shall be clearly identified in the construction documents.
SIGNAGE
84. Per Section 1013.4, tactile exit signs shall be required at the following locations:
a) Wherever basic CBC provisions require exit signs from a room or area to a
corridor or hallway. The tactile exit sign shall have the words, "EXIT
ROUTE."
b) Each grade-level exit door. The tactile exit sign shall have the word, "EXIT."
c) Each exit door that leads directly to a grade-level exterior exit by means of a
stairway or ramp. The tactile exit sign shall have the following words as
appropriate:
i) "EXIT STAIR DOWN."
ii) "EXIT RAMP DOWN ."
iii) "EXIT STAIR UP."
iv) "EXIT RAMP UP."
d) Each exit door that leads directly to a grade-level exterior exit by means of
an exit enclosure or an exit passageway. The tactile exit sign shall have the
words, "EXIT ROUTE."
e) Each exit door through a horizontal exit. The tactile exit sign shall have the
words, "TO EXIT."
ACCESSIBLE ROUTE OF TRAVEL
85. Accessible routes of travel shall be provided from public transportation stops,
accessible parking and accessible passenger loading zones, and public streets
or sidewalks to the accessible entrance they serve. The accessible route shall to
the extent feasible, coincide with the route for the general public. Section
111 0A.1.
86. Where more than one route of travel is provided, all routes shall be accessible.
Section 111 0A. 1. 1 .
87. General: All common use areas (lobbies, restrooms, community rooms, pools,
etc., that serve accessible dwelling units shall be accessible. Section 1127 A.1 .
Please provide more information regarding the common use areas, as they
currently refer you to "interior drawings," which are not found in the set.
88. A minimum linear length of 30" of countertop shall be provided for the kitchen
sink, and a minimum linear length of 30" of countertop shall be provided for a
work surface, both of which shall be designed to enable repositioning to a
minimum height of 28 inches. Section 1133A.4.
Exceptions:
i) Only 5% of covered dwelling units are required to comply with the
repositionable countertop requirements.
ii) Stone, cultured stone, and tiled countertops may be used without
meeting the repositioning requirements.
iii) In covered dwelling units, two 15-inch minimum width breadboards
may be provided in lieu of the required 30 inches of countertop
work surface.
89. Please stipulate the source of funds for the project. Are public finds being used to
finance the project? Please advise.
Building Permit Finaled
Revision Permit
Print Date: 06/26/2025
Job Address: 1205 AVIARA PKWY, CARLSBAD, CA 92011-1276
Permit No:
Status:
Ccityof
Carlsbad
PREV2023-0167
Closed -Finaled
Permit Type: BLDG-Permit Revision Work Class: Commercial Permit Revision
Parcel#: 2120405600 Track#: Applied: 08/21/2023
Valuation: $0.00 Lot#: Issued: 05/28/2025
Occupancy Group: S Project#: DEV2017-0033 Finaled Close Out: 06/26/2025
#of Dwelling Units: Plan#:
Bedrooms: Construction Type:
Bathrooms:
Occupant Load:
Orig. Plan Check#: CBC2021-0489
Plan Check #:
Code Edition:
Sprinkled:
Project Title: AVIARA APARTMENTS
Description: AVIARA APARTMENTS: DEFERRED STAIR SUBMITTAL
Applicant:
WERMERS PROPERTIES
5120 SHOREHAM PL, # STE 150
SAN DIEGO, CA 92122-5959
(858) 535-1475
FEE
Property Owner:
AVIARA LP
AUSTIN W
5120 SHOREHAM PL, # 150
SAN DIEGO, CA 92122-5959
(858) 535-1475
BUILDING PLAN CHECK REVISION ADMIN FEE
THIRD PARTY REVIEW-Consultant Cost (BLDG)
THIRD PARTY REVIEW-Consultant Cost (BLDG)
Total Fees: $575.00 Total Payments To Date:
Building Division
$575.00
Final Inspection:
INSPECTOR:
Contractor:
WERMERS MULTI-FAMILY CORP
5120 SHOREHAM PL, # STE 150
SAN DIEGO, CA 92122-5959
(858) 535-1475
Balance Due:
AMOUNT
$35.00
$300.00
$240.00
$0.00
Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
( City of
Carlsbad
PLAN CHECK REVISION OR
DEFERRED SUBMITTAL
APPLICATION
Development Services
Building Division
1635 Faraday Avenue
442-339-2719
www.carlsbadca.gov 8-15 ____ , ________ _,
for,,u'JJ,'YJ4 P-orrn,·+ Fc3C,UJ1./ -0'1~~
Original Plafl Check !\lumber ________ Plan Revision Number Ff?,0J 2.02.3--0\ b /
Project Address }20 !7 AY,a vq fkw,r
General Scope of Revision/Deferred Submittal: ---'Pt~k--=...;r......:..rW.x:..= __ J~fet,........,'"""' y-__ ~ __ b_V'J'l_r'_f-_k/i_( ___ _
CONTACT INFORMATION:
Name U)* Phone "flfq-6Pf3'-DG3o Fax'-----------
Address ____________________ City ______ Zip ____ _
Email Address __ C'-"~'-'--""+-J___,__e,,~w._,-c:,r"'---_,,..,=0:.__c:__-=U=-VVl__,_f._'/,/_l'J_;_~_-_.:.C()=---VVl ___________ _
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1 . Elements revised: D Plans D Calculations D Soils D Energy D Other
2.
Describe revisions in detail
4. Does this revision, in any way, alter the exterior of the project?
5. Does this revision add ANY new floor area(s)? D Yes
6. Does this revision affect any fire related issues? D Yes
7. Is this a complete set? D Yes D No
£.S'Signature__.<;~_.c:...-=,,-_ __.__~~LlL,~~v=---------
D Yes
0 No
0 No
Date
3.
List page(s) where each
revision is shown
0 No
~/2.../,/23
1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 442-339-27 19 Fax: 760-602-8558 Email: building@carlsbadca.gov
www.carlsbadca.gov
March 14, 2024
City of Carlsbad
Community Development Department -Building Division
1635 Faraday Ave.
Carlsbad, CA 92008
Plan Review: Deferred Submittal Tl
Address: 1205 A viara Parkway
Applicant Name: Corey Johnson
Applicant Email: CoreyJ@wermerscompanies.com
OCCUPANCY AND BUILDING SUMMARY:
Occupancy Groups: NI A
Occupant Load: NI A
Type of Construction: NI A
Sprinklers: NIA
Stories: NI A
Area of Work (sq. ft.): NIA sq. ft.
The plans have been reviewed for coordination with the permit application.
Valuation: See Notes Below
Scope of Work: Confirmed
Floor Area: See Notes Below
Deferred submittal, no valuation or floor area
Attn: Building & Safety Department,
J TrueNorth
,I COMPLIANCE SERVICES
City of Carlsbad -FINAL REVIEW
City Permit No: PREV2023-0167
True North No.: 23-01 8-806
True North Compliance Services, Inc. has completed the final review of the following documents for the project
referenced above on behalf of the City of Carlsbad:
I.
2.
Drawings: One (I) copy dated June 8, 2023, by Buildwise Inc.
Structural Calculations: One (I) copy dated September 18, 2023, by Orie Engineering.
The 2022 California Building, Mechanical, Plumbing, and Electrical Codes (i.e., 2021 !BC, UMC, UPC, and 2020
NEC, as amended by the State of California), 2022 California Green Building Standards Code, 2022 California
Existing Building Code, and 2022 California Energy Code, as applicable, were used as the basis of our review.
Please note that our review has been completed and we have no further comments, however, we bring the
following to your attention:
I . This project is Hourly. Please charge the applicant the following hours of plan review.
True North Compliance Services, Inc.
8369 Vickers Street, Suite 207, San Diego, CA 92111
T / 562.733.8030
Review No. Hourly Rate Hours Total
1st Review $120.00 2.5 $300
2nd Review $120.00 2 $240
Total $540
We have enclosed the above noted documents bearing our review stamps for your use. Please call if you have any
questions or if we can be of further assistance.
Sincerely,
True North Compliance Services
Review By: Alaa Atassi -Plan Review Engineer
Orie2 Engineering
Structural Engineers
9750 Miramar Road, Suite 310
San Diego, CA 92126
Fax: (658) 586-0911
Structural Calculations
PROJECT: Aviara-lFA-Stairs Garage
(Project# 158.033-23 )
CLIENT: PCIW
DESIGNED BY:
ESY
DATE:
9/18/23
Orie2 -Structural Engineers
Orie2 Engineering
Structural Engineers
9750 Miramar Road, Suite 310
San Diego, CA 92126
Fax: (858) 586-0911
Structural Calculations -Table of Contents
Aviara-lFA-Stairs Garage
Orie2 Job No . .-158.033-23
I
1. Design Criteria & Loads ................................................................................ 1 -5
2. Stairs Model .................................................................................................. 6 -26
3. Stairs Connections Analysis ....................................................................... 27 -56
4. Railing Analysis .......................................................................................... 57 -82
5. Appendix ..................................................................................................... 83 -86
3/17/23, 10:54 AM ATC Hazards by Location
A This is a beta release of the new ATC Hazards by Location website. Please ~ with feedback.
O The ATC Hazards by Location website will not be updated to support ASCE 7-22. ~Y,
l\TC Hazards by Location
Search Information
AdclreH:
Coordlnatff:
Elevation:
TlrnHtamp:
Hazard Type:
Rer.renc:e Document:
Rlak Catego,y:
Site ClaH:
Basic Parameters
Name Value
Ss 1.041
S1 0.3TT
SMs 1,249
SM1 • null
Sos 0.833
So1 • null
• See Section 11.4.8
1205Avlara Pkwy, Carisbad, CA92011, USA
33.1217135, -117.3029721
85ft
2023-03-17T17:54:23.189Z
Seismic
ASCE7-16
D-default
l>ffc:rtptlon
MCER ground motion (period=0.2s)
MCER ground motion (period=1.0s)
Site-modified spectral acceleration value
Site-modified spectral acceleration value
Numeric seismic design value at 0.2s SA
Numeric seismic design value at 1.0s SA
Go gle
..,Additional Information
Name Value l>ffc:tlptlon
SDC • null Seismic deslgn category
F, 1.2 Site amplification factor at 0.2s
Fv • null Site amplification factor et 1.0s
CRs 0.894 Coefficient of risk (0.2s)
CR1 0.905 Coefficient of risk (1.0s)
PGA 0.458 MCEo peak ground acceleration
FPGA 1.2 Site amplification factor at PGA
PG~ 0.549 Site modified peak ground acceleration
TL 8 Long-period transition period (s)
SsRT 1.041 Probablllsllc risk-targeted ground motion (0.2s)
SsUH 1.165 Factored uniform-hazard spectral acceleration (2% probability of
exceedanca In 50 years)
SsD 1.5 Factored deterministic acceleration value (0.2s)
S1RT 0.377 Probabilistic risk-targeted ground motion (1.0s)
S1UH 0.417 Factored uniform-hazard spectral acceleration (2% probability of
exceedanca In 50 years)
S1D 0.6 Factored detennlnistic acceleration value (1.0s)
PGAd 0.531 Factored detennlnlstic acceleration value (PGA)
• See Section 11 .4.8
Temecula 0.
0 Escondido
San Diego
..
Borrego
Sp,i:,g•
Page 1
Anza-Borrego
Desert State Park
Cleveland
National F.orest i Map data C2023 Google, INEGI
The results indicated here DO NOT reflect any stal9 or local amendments to the valU6S or any de/lneation lines made during the building code adopllon process. Users should confirm any
output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design.
Please note that the ATC Hazards by Locallon website will not be updated to support ASCE 7-22. ~y,
Disclaimer
https://hazards.atcouncil.org/#/seismic?lat=33.1217135&Ing=-117.3029721 &address=1205 Aviara Pkwy%2C Car1sbad%2C CA 92011 %2C USA 1/2
.0
Orie2 Engineering
Structural Engineers
9750 Mlfama, Road, Su,te 3 10
San 0,ego. CA 92126
Fax· (858) 586-0911
Project No. : 158.033-23
PROJECT : Aviara-lFA-Stairs Garage
Aviara Garage Stairs #1 & #2
-:· t4 4!.o -: ~ I 1 NL NL ~/l.:.,.l'-7 ---:TR=,EAO:-:-::c"O,a,IH=-.-+----,f,, j--F · F ·
Page 2
DATE: 3/16/23
BY : ESY
I --, : I, I
CHU WALL .~if 1!.U•/• i' 1!.U•/• ,}i I u:
-~--TY_P_. ___ 3t......_J.__ _______________ ..._-t+-----+---,1 __ ...,_ _ _,1 U:
l/2 0.0. TUBE
o\NORAIL (TYP)
U/2 0.0. TUBE
CAIN RAIL
TYP
----:-: I
I
1--I-_,_
I I
I I
I I
I I
I
I
I
--1
I
I
I
-<:.a:: -d
I
I
I
I
I
I -~
I
I
I
UP I
I
I
I
_J -I
I
I
I I' I I : 'L ________ _
I I
I I
I I _I __ I _
I I
I I
UP I I
I
I
I
I
I
I :+---'-t-tt--..1
I --I --
2"LT.WT.CONCRtft 1 OVER 10 GA.Pl I t 1 I I EL'.-6°-3 4"'
I I T o. LAN NG I I 1 1
NL ,I'~ 4
.:.,_1<-l --~T"'R"'EAD'T41'<"!.0,.D"'IrrM-. +---.rJ ! -L ,,
• 4!.4 -~-
2"LT .WT .CONCRETE
OVER 10 GA.Pl
u.
u.
p
"'
5-.... --_, ...
'$
0 _,
N
"' .,
"'
0 ... ... N
.,,
Orie2 Engineering
Structural Engineers
9750 M,nun.r Road, Surte 310
s.n Diego, CA 92126
Fax (858) 586-0911
_,
""0 ... J
N
HSS 1/ 2X3/16
POST '4'-0 O.C
HSS5 8X5/8Xl 16
PICKETS '4"0.C
1.---N.L.
Project No. : 158.033-23
PROJECT: Aviara-lFA-Stairs Garage
Aviara Garage Stairs #1 & #2
I
I ... ., 7 TREADS Ill• 6~5
N.L.----l
L
F.F,--..j
L3X3X1/4 SUPPORT
3Xl/4 I UPPORT
-7',r-'-----------------
12
CMU WALL (TYP)
Page 3
DATE : 3/16/23
BY : ESY
00
'+~ci J ~ ...
-~r-~-~~ ::. . _, "' ... --~r--,..,.
$
I ._,
$~
~ffi "'.., ~= !." 1 ... N I-
"' -' i 00 ~§
!"' ...
,..,.
~
' ._,
$, : "'.., _, .,, ..,. !i
"' "l ...
"' j~
00 ~ .
I C! iii I-
-~r-• ~ Ii :-,, ... .,, "'i "'. I ~
;!., ~ 1~ "' irl I-..,.
91:li ;.., I=
Orie 1 Engineering
Structural & Bridge Engineers
Project No.· _l5~8~.0~33-~2'"3 _________ _
9750 M11amar Road. Surte 310
San Diego. CA 92126
Phone# (858) 335-7643 PROJECT Avlar•IFA-Stalrs Garage
SEISMIC DEMANDS ON NONSTRUCTURAL COMPONENTS ASCE 7-16 13.3.1
Code: 2022 CBC, ASCE 7-16 CHAPTER 11 , 12, 13 SEISMIC DESIGN CRITERIA
Soil Site Class: D Table 20-3-1, Default = D
s.: 104.1
S1: 37.7
F.: 1.200
Fv: 1.923
SMs: 1.249
SM1: 0.725
S05: 0.833
So1: 0.483
%g
%g
(USGS using Latitude/Longitude)
Table 11.4-1
Table 11.4-2
F.s.
F,S1
2/3(SMs)
2/3(SM,)
Occupancy: Component: Egress Stair
Ip: 1.5 ASCE 7-16, Section 13.1.3
Component= Rigid -Limited deformability elements and attachments
ap = 1 ASCE 7-16, Table 13.5-1 or 13.6-1
Rp = 2.5
ht. of struct to pt. of attachment, z = 5
ave. roof height to base, h = 6
Seismic Force:
F p = 0 .4apSos
(R,/lp)
Fp = 0.533 x WP
F p,m;n = 0.3Soslp
F p,m;n = 0.375
F p,mu = 1.6Soslp
F p.m .. = 1.999
FP = 0.533
X (1+2(z/h)) X Wp ASCE 7-16, Eq 13.3-1
<-Governs
ASCE 7-16. Eq 13.3-3
ASCE 7-16, Eq 13.3-2
(LRFD)
Page 4
DATE: 03117/23
BY. ESY
Orie 2 Engineering Project No. :_1_58_.0_3_3_-2_3 _____ _ DATE :
Structural & Bridge Engineers
9750 Miramar Rd., Suite 310 Phone#: (858) 335-7643 PROJECT : Aviara-lFA-Stairs Garage BY :
San Diego, CA 92126
Gravity Design Loads
CODE: 2022 California Building Code (CBC)
DEAD LOAD
Stringer Dead Load
Precast Treads
Misc.
MC12x10.6 Stringer
Landing Dead Load
10 GA Metal Pan
2' Lightweight Concrete Fill
Framing Members
FLOOR LIVE LOADS:
Seismic Design@ Stringers
Fp Seismic=
MC12x10.6 =
1 /2 Width of Stairs =
Fp =
Seismic Design @ Landing
Fp Seismic=
MC12x10.6 =
C8x11.5 =
C4x7.25 =
Total Area of Landing =
Length of Seismic Members =
Fp =
Sub-Total :
Total :
Sub-Total :
38.0 psf
2.0 psf
40.0 psf
5.3 psf
45.3 psf
6.0 psf
19.0 psf
25.0 psf
Varies
100.0 psf
0.533 •w (Strength)
10.6 plf
2.00 ft
48.3 plf
Egress Stairs
0.533 •w (Strength)
10.6 plf
11.5 plf
7.25 plf
Total Length of MC12x10.6 =
Total Length of C8x 11.5 =
Total Length of C4x7.25 =
8 ft Weight of MC12x10.6 =
8 ft Weight of C8x11.5 =
4 ft Weight of C4x7.25 =
Total Weight of Landing Members =
16.0 sqft
20 0 ft 'Seismic Members' are members to which seismic load is applied in the analysis
16.1 plf Fp = ( Total Weight of Landing Members x Cs I Length of Seismic Members)
Page 5
03/17/23
ESY
84.8 lb
92 lb
29 lb
206 lb
+ ( Dead Load (PSF) x Total Area of Landing x Cs / Length of Seismic Members )
Envelope Only Solution
IIIRISA Orie2 Engineering, Inc.
"' ESY
Section Set
SK-1
Page 6
Section Sets
IMC12x10.6
C8x11 .,5
C4x7.25
Mar 17, 2023 at 04:34 PM
Aviara Stairs GARAGE.r3d
Loads: BLC 1, D
Envelope Only Solution
IIIRISA ~;~2 Engineering, Inc.
1',(W ,c.: .. t..::.::::...:... ________ I
Dead Load
Page 7
SK-2
Mar 17, 2023 at 04:35 PM
Aviara Stairs GARAGE.r3d
Loads: BLC 2, L
Envelope Only Solution
IIIRISA l.20:::r::ie:..2..::.E:..:..:ng~in.:..:e..:..er_in..:::.g:_, l_nc_._1 •• ,,.. """ =··' L~ES~Y---------1
Live Load
Page 8
SK-3
Mar 17, 2023 at 04:35 PM
Aviara Stairs GARAGE.r3d
Loads: BLC 3, Ex
Envelope Only Solution
Ill RISA 1-0_r_ie_2_E_n_g_in_ee_r_in_g_, l_nc_._---1
ESY
Seismic Load X
Page 9
SK-4
Mar 17, 2023 at 04:35 PM
Aviara Stairs GARAGE.r3d
Loads: BLC 4, Ez
Envelope Only Solution
IIIRISA 1--0_r_ie2_En_g_in_e_er_in_g,_l_nc_. ----1
ESY
Seismic Load Z Page 10
0.017 k/ft
SK-5
Mar 17, 2023 at 04:35 PM
Aviara Stairs GARAGE.r3d
Member Code Checks Displayed (Enveloped)
Envelope Only Solution
IIIRISA Orie2 Engineering, Inc.
.,.. ... ESY
Code Check (Bending)
SK-6
Page 11
Code Check
(Env)
No Cale
> 1.0
.90-1.0
.75-.90
.50-.75
0.-.50
Mar 17, 2023 at 04:35 PM
Aviara Stairs GARAGE.r3d
Company
Designer
: Orie2 Engineering, Inc.
: ESY IIIRISA
A NEMETSCHEK COMPANY
Job Number
Model Name :
Model Settings
Number of Reoorted Sections
Number of Internal Sections
Member Area Load Mesh Size (in2)
Consider Shear Deformation
Consider Torsional Waroina
Annroximate Mesh Size (in)
Transfer Forces Between lntersectina Wood Walls
Increase Wood Wall Nailina Caoacitv for Wind Loads
Include P-Delta for Walls
Ootimize Masonrv and Wood Walls
Maximum Number of Iterations
Sinale
Multiole (Ootimum)
Maximum
Global Axis corresoondina to vertical direction
Convert Existina Data
Default Global Plane for z-axis
Plate Local Axis Orientation
Hot Rolled Steel
Stiffness Adiustment
Notional Annex
Connections
Cold Formed Steel
Stiffness Adiustment
Wood
Temoerature
Concrete
Masonrv
Aluminum
Structure Tvoe
Stiffness Adiustment
Stainless
Stiffness Adiustment
Comoression Stress Block
Analvze usina Cracked Sections
Leave room for horizontal rebar solices (2*d bar soacina)
List forces which were ianored for desian in the Detail Reoort
Column Min Steel
Column Max Steel
Rebar Material Snee
Warn if beam-column framina arranaement is not understood
Number of Shear Reaions
Reaion 2 & 3 Soacina Increase Increment (in)
Code
Risk Cateaorv
Drift Cat
5
100
144
Yes
Yes
24
Yes
Yes
Yes
Yes
3
No
Yes
No
y
Yes xz
Global
AISC 15th (360-16): ASD
Yes (Iterative)
None
AISC 14th (360-10): ASD
AISI S100-16: ASD
Yes <Iterative)
AWC NDS-18 / SDPWS-15 ASD
< 100F
ACI 318-19
TMS 402-16: ASD
MADM1-15:ASD
Buildina
Yes (Iterative)
AISC 14th (360-10): ASD
Yes <Iterative)
Rectanaular Stress Block
Yes
Yes
Yes
1
8
ASTM A615
No
4
4
ASCE 7-16
I or II
Other
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d ]
Page 12
3/17/2023
4:58:20 PM
Checked By :
Page 1
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A NEMETSCHEK COMPANY Model Name :
Model Settinas (Continued)
Base Elevation fft)
Include the weiaht of the structure in base shear calcs Yes
S (a) 1
SD <a) 1
SD. fa) 1
T, (sec) 5
T Z (sec)
TX (sec)
C,Z 0.02
c.x 0.02
C,Exn. Z 0.75
CExo. X 0.75
RZ 3
RX 3
Q.7 1
Q .')( 1
cdz 4
c.x 4
oz 1
ox 1
RISA-3D Version 21 [Aviara Stairs GARAGE.r3d]
Page 13
3/17/2023
4:58:20 PM
Checked By :
Page 2
IIIRISA
A NEMETSCHfK COMPANY
Node Coordinates
Label
1 N17
2 N18
3 N19
4 N20
5 N21
6 N22
7 N23
8 N24
9 N25
10 N26
11 N27
12 N28
13 N29
14 N30
15 N31
16 N32
17 N33
18 N34
19 N35
20 N36
21 N37
22 N38
23 N39
24 N40
25 N41
26 N42
27 N43
28 N44
29 N45
30 N46
31 N47
32 N48
33 N49
34 N50
35 N51
36 N52
37 N53
38 N54
39 N55
40 N56
41 N57
42 N58
43 N59
44 N60
45 N61
46 N62
47 N63
48 N64
49 N65
50 N66
51 N67
52 N68
53 N69
54 N70
55 N71
RISA-3D Version 21
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name :
X [ft] y [ft] z [ft]
28.582907 -11.250288 -0.000333
21 .16624 -4.500287 -11.083666
21 .16624 -4.500287 -7.083666
28.582907 -6.750287 -9.083666
24.582907 -11.250288 -0.000333
17.16624 -0.000287 -0.000333
17.16624 -4.500287 -11.083666
21 .16624 -0.000287 -0.000333
28.582907 -6.750287 -7.083666
28.582907 -6.750287 -11.083666
17.16624 -4.500287 -7.083666
24.582907 -6.750287 -7.083666
24.582907 -6.750287 -11.083666
24.582907 -6.750287 -9.083666
19.16624 -4.500287 -11.083666
19.16624 -4.500287 -7.083666
28.582907 -6.750287 -8.083666
17.16624 -4.500287 -8.083666
17.16624 -4.500287 -10.583666
28.582907 -6.750287 -10.583666
28.082907 -6.750287 -11.083666
25.582907 -6.750287 -11 .083666
17.66624 -4.500287 -11 .083666
20.16624 -4.500287 -11.083666
17.16624 -4.500287 -7.583666
17.66624 -4.500287 -7.583666
17.66624 -4.500287 -7.083666
18.16624 -4.500287 -7.583666
18.16624 -4.500287 -7.083666
18.66624 -4.500287 -7.583666
18.66624 -4.500287 -7.083666
19.16624 -4.500287 -7.583666
19.66624 -4.500287 -7.583666
19.66624 -4.500287 -7.083666
20.16624 -4.500287 -7.583666
20.16624 -4.500287 -7.083666
20.66624 -4.500287 -7.583666
20.66624 -4.500287 -7.083666
21 .16624 -4.500287 -7.583666
17.66624 -4.500287 -8.083666
18.16624 -4.500287 -8.083666
18.66624 -4.500287 -8.083666
19.16624 -4.500287 -8.083666
19.66624 -4.500287 -8.083666
20.16624 -4.500287 -8.083666
20.66624 -4.500287 -8.083666
21.16624 -4.500287 -8.083666
17.16624 -4.500287 -8.583666
17.66624 -4.500287 -8.583666
18.16624 -4.500287 -8.583666
18.66624 -4.500287 -8.583666
19.16624 -4.500287 -8.583666
19.66624 -4.500287 -8.583666
20.16624 -4.500287 -8.583666
20.66624 -4.500287 -8.583666
[ Aviara Stairs GARAGE.r3d ]
Page 14
3/17/2023
4:58:20 PM
Checked By :
Detach From Diaphraam
Page 3
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
,._ NEIAl'TSCHEK COMPI\NY Model Name:
Node Coordinates (Continued)
Label X fftl Y fftl Z fftl
56 N72 21.16624 -4.500287 -8.583666
57 N73 17.16624 -4.500287 -9.083666
58 N74 17.66624 -4.500287 -9.083666
59 N75 18.16624 -4.500287 -9.083666
60 N76 18.66624 -4.500287 -9.083666
61 N77 19.16624 -4.500287 -9.083666
62 N78 19.66624 -4.500287 -9.083666
63 N79 20.16624 -4.500287 -9.083666
64 N80 20.66624 -4.500287 -9.083666
65 N81 21.16624 -4.500287 -9.083666
66 N82 17.16624 -4.500287 -9.583666
67 N83 17.66624 -4.500287 -9.583666
68 N84 18.16624 -4.500287 -9.583666
69 N85 18.66624 -4.500287 -9.583666
70 N86 19.16624 -4.500287 -9.583666
71 N87 19.66624 -4.500287 -9.583666
72 N88 20.16624 -4.500287 -9.583666
73 N89 20.66624 -4.500287 -9.583666
74 N90 21.16624 -4.500287 -9.583666
75 N91 17.16624 -4.500287 -10.083666
76 N92 17.66624 -4.500287 -10.083666
77 N93 18.16624 -4.500287 -10.083666
78 N94 18.66624 -4.500287 -10.083666
79 N95 19.16624 -4.500287 -10.083666
80 N96 19.66624 -4.500287 -10.083666
81 N97 20.16624 -4.500287 -10.083666
82 N98 20.66624 -4.500287 -10.083666
83 N99 21.16624 -4.500287 -10.083666
84 N100 17.66624 -4.500287 -10.583666
85 N101 18.16624 -4.500287 -10.583666
86 N102 18.66624 -4.500287 -10.583666
87 N103 19.16624 -4.500287 -10.583666
88 N104 19.66624 -4.500287 -10.583666
89 N105 20.16624 -4.500287 -10.583666
90 N106 20.66624 -4.500287 -10.583666
91 N107 21.16624 -4.500287 -10.583666
92 N108 18.16624 -4.500287 -11.083666
93 N109 18.66624 -4.500287 -11.083666
94 N110 19.66624 -4.500287 -11 .083666
95 N111 20.66624 -4.500287 -11.083666
96 N112 24.582907 -6.750287 -7.583666
97 N113 25.082907 -6.750287 -7.583666
98 N114 25.082907 -6.750287 -7.083666
99 N115 25.582907 -6.750287 -7.583666
100 N116 25.582907 -6.750287 -7.083666
101 N117 26.082907 -6.750287 -7.583666
102 N118 26.082907 -6.750287 -7.083666
103 N119 26.582907 -6.750287 -7.583666
104 N120 26.582907 -6.750287 -7.083666
105 N121 27.082907 -6.750287 -7.583666
106 N122 27.082907 -6.750287 -7.083666
107 N123 27.582907 -6.750287 -7.583666
108 N124 27.582907 -6.750287 -7.083666
109 N125 28.082907 -6.750287 -7.583666
110 N126 28.082907 -6.750287 -7.083666
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d ]
Page 15
3/17/2023
4:58:20 PM
Checked By :
Detach From Diaphragm
Page4
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A NEMETSCHEK COMPANY Model Name :
Node Coordinates {Continued/
Label X rttl y [ft] Z lftl
111 N127 28.582907 -6.750287 -7.583666
112 N128 24.582907 -6.750287 -8.083666
113 N129 25.082907 -6.750287 -8.083666
114 N130 25.582907 -6.750287 -8.083666
115 N131 26.082907 -6.750287 -8.083666
116 N132 26.582907 -6.750287 -8.083666
117 N133 27.082907 -6.750287 -8.083666
118 N134 27.582907 -6.750287 -8.083666
119 N135 28.082907 -6.750287 -8.083666
120 N136 24.582907 -6.750287 -8.583666
121 N137 25.082907 -6.750287 -8.583666
122 N138 25.582907 -6.750287 -8.583666
123 N139 26.082907 -6.750287 -8.583666
124 N140 26.582907 -6.750287 -8.583666
125 N141 27.082907 -6.750287 -8.583666
126 N142 27.582907 -6.750287 -8.583666
127 N143 28.082907 -6.750287 -8.583666
128 N144 28.582907 -6.750287 -8.583666
129 N145 25.082907 -6.750287 -9.083666
130 N146 25.582907 -6.750287 -9.083666
131 N147 26.082907 -6.750287 -9.083666
132 N148 26.582907 -6.750287 -9.083666
133 N149 27.082907 -6.750287 -9.083666
134 N150 27.582907 -6.750287 -9.083666
135 N151 28.082907 -6.750287 -9.083666
136 N152 24.582907 -6.750287 -9.583666
137 N153 25.082907 -6.750287 -9.583666
138 N154 25.582907 -6.750287 -9.583666
139 N155 26.082907 -6.750287 -9.583666
140 N156 26.582907 -6.750287 -9.583666
141 N157 27.082907 -6.750287 -9.583666
142 N158 27.582907 -6.750287 -9.583666
143 N159 28.082907 -6.750287 -9.583666
144 N160 28.582907 -6.750287 -9.583666
145 N161 24.582907 -6.750287 -10.083666
146 N162 25.082907 -6.750287 -10.083666
147 N163 25.582907 -6.750287 -10.083666
148 N164 26.082907 -6.750287 -10.083666
149 N165 26.582907 -6.750287 -10.083666
150 N166 27.082907 -6.750287 -10.083666
151 N167 27.582907 -6.750287 -10.083666
152 N168 28.082907 -6.750287 -10.083666
153 N169 28.582907 -6.750287 -10.083666
154 N170 24.582907 -6.750287 -10.583666
155 N171 25.082907 -6.750287 -10.583666
156 N172 25.582907 -6.750287 -10.583666
157 N173 26.082907 -6.750287 -10.583666
158 N174 26.582907 -6.750287 -10.583666
159 N175 27.082907 -6.750287 -10.583666
160 N176 27.582907 -6.750287 -10.583666
161 N177 28.082907 -6.750287 -10.583666
162 N178 25.082907 -6.750287 -11.083666
163 N179 26.082907 -6.750287 -11.083666
164 N180 26.582907 -6.750287 -11.083666
165 N181 27.082907 -6.750287 -11.083666
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d )
Page 16
3/17/2023
4:58:20 PM
Checked By :
Detach From DiaphraQm
Page 5
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A NEMETSCHEK COMPANY Model Name :
Node Coordinates (Continued)
Label X ft y ft
166 N182 27.582907 -6.750287
Hot Rolled Steel Properties
z ft
-11.083666
Page 17
311712023
4:58:20 PM
Checked By :
Detach From Dia hra m
Label E [ksil G [ksil Nu Therm Coeff 11 e5°F-'1 Densitv lk/ft3l Yield lksil Rv Fu fksi] Rt
1 A992 29000 11154 0.3 0.65 0.49 50 1.1 65 1.1
2 A36 Gr.36 29000 11154 0.3 0.65 0.49 36 1.5 58 1.2
3 A572 Gr.50 29000 11154 0.3 0.65 0.49 50 1.1 65 1.1
4 A500 Gr.B RND 29000 11154 0.3 0.65 0.527 42 1.4 58 1.3
5 A500 Gr.B RECT 29000 11154 0.3 0.65 0.527 46 1.4 58 1.3
6 A500 Gr.C RND 29000 11154 0.3 0.65 0.527 46 1.4 62 1.3
7 A500 Gr.C RECT 29000 11154 0.3 0.65 0.527 50 1.4 62 1.3
8 A53 Gr.B 29000 11154 0.3 0.65 0.49 35 1.6 60 1.2
9 A1085 29000 11154 0.3 0.65 0.49 50 1.4 65 1.3
10 A913 Gr.65 29000 11154 0.3 0.65 0.49 65 1.1 80 1.1
Hot Rolled Steel Design Parameters
Label Shaoe Lenath lftl Lb v-v lftl Lb z-z lftl Lcomo too lftl Lcomo bot lftl Channel Conn a fftl Function
1 M17 MC12x10.6 4.091 1 1 1 1 NIA NIA Lateral
2 M18 MC12x10.6 8.392 1 1 1 1 NIA NIA Lateral
3 M19 MC12x10.6 4 1 1 NIA NIA Lateral
4 M20 C8x11 .5 4 1 1 NIA NIA Lateral
5 M21 MC12x10.6 4 1 1 NIA NIA Lateral
6 M22 C8x11 . 5 4 1 1 N/A N/A Lateral
7 M23 MC12x10.6 4 1 • 1 NIA NIA Lateral
8 M24 C8x11 .5 4 1 1 NIA NIA Lateral
9 M25 MC12x10.6 8.392 1 1 1 1 NIA NIA Lateral
10 M26 MC12x10.6 4.091 1 1 1 1 NIA NIA Lateral
11 M27 MC12x10.6 8.392 1 1 1 1 NIA NIA Lateral
12 M28 MC12x10.6 8.392 1 1 1 1 NIA NIA Lateral
13 M29 MC12x10.6 4 1 1 NIA NIA Lateral
14 M30 C8x11. 5 4 1 1 NIA NIA Lateral
15 M31 C4x7.25 4 1 1 NIA NIA Lateral
16 M32 C4x7.25 4 1 1 NIA NIA Lateral
Hot Rolled Steel Section Sets
Label Shaoe Tvoe Desian List Material Desian Rule Area lin2l lvv lin4l lzz [in•] J lin•l
1 MC12x10.6 MC12X10.6 Beam Channel A36 Gr.36 Tvnical 3.1 0.378 55.3 0.06
2 C8x11 . 5 C8X11.5 Beam Channel A36 Gr.36 Tvnical 3.37 1.31 32.5 0.13
3 C4x7.25 C4X7.25 Beam Channel A36 Gr.36 Tvnical 2.13 0.425 4.58 0.082
Plate Primary Data
Label A Node B Node C Node D Node Material Thickness finl
1 P3 N27 N41 N42 N43 nen Steel 0.135
2 P4 N43 N42 N44 N45 aen Steel 0.135
3 P5 N45 N44 N46 N47 aen Steel 0.135
4 P6 N47 N46 N48 N32 nen Steel 0.135
5 P7 N32 N48 N49 N50 aen Steel 0.135
6 P8 N50 N49 N51 N52 nen Steel 0.135
7 pg N52 N51 N53 N54 aen Steel 0.135
8 P10 N54 N53 N55 N19 nen Steel 0.135
RISA-3D Version 21 [Aviara Stairs GARAGE.r3d] Page6
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A NEMFTSCHEK COMPANY Model Name :
Plate Primary Data {Continued)
Label A Node B Node C Node D Node
9 P11 N41 N34 N56 N42
10 P12 N42 N56 N57 N44
11 P13 N44 N57 N58 N46
12 P14 N46 N58 N59 N48
13 P15 N48 N59 N60 N49
14 P16 N49 N60 N61 N51
15 P17 N51 N61 N62 N53
16 P18 N53 N62 N63 N55
17 P19 N34 N64 N65 N56
18 P20 N56 N65 N66 N57
19 P21 N57 N66 N67 N58
20 P22 N58 N67 N68 N59
21 P23 N59 N68 N69 N60
22 P24 N60 N69 N70 N61
23 P25 N61 N70 N71 N62
24 P26 N62 N71 N72 N63
25 P27 N64 N73 N74 N65
26 P28 N65 N74 N75 N66
27 P29 N66 N75 N76 N67
28 P30 N67 N76 N77 N68
29 P31 N68 N77 N78 N69
30 P32 N69 N78 N79 N70
31 P33 N70 N79 N80 N71
32 P34 N71 N80 N81 N72
33 P35 N73 N82 N83 N74
34 P36 N74 N83 N84 N75
35 P37 N75 N84 N85 N76
36 P38 N76 N85 N86 N77
37 P39 N77 N86 N87 N78
38 P40 N78 N87 N88 N79
39 P41 N79 N88 N89 N80
40 P42 N80 N89 N90 N81
41 P43 N82 N91 N92 N83
42 P44 N83 N92 N93 N84
43 P45 N84 N93 N94 N85
44 P46 N85 N94 N95 N86
45 P47 N86 N95 N96 N87
46 P48 N87 N96 N97 N88
47 P49 N88 N97 N98 N89
48 P50 N89 N98 N99 N90
49 P51 N91 N35 N100 N92
50 P52 N92 N1 00 N101 N93
51 P53 N93 N101 N102 N94
52 P54 N94 N102 N103 N95
53 P55 N95 N103 N104 N96
54 P56 N96 N104 N105 N97
55 P57 N97 N105 N106 N98
56 P58 N98 N106 N107 N99
57 P59 N35 N23 N39 N100
58 P60 N100 N39 N1 08 N101
59 P61 N101 N108 N109 N102
60 P62 N102 N109 N31 N103
61 P63 N103 N31 N110 N104
62 P64 N104 N110 N40 N105
63 P65 N105 N40 N111 N106
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d ]
Material
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
cien Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
cien Steel
aen Steel
qen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
cien Steel
aen Steel
_gen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
cien Steel
aen Steel
aen Steel
aen Steel
Page 18
3/17/2023
4:58:20 PM
Checked By :
Thickness finl
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.1 35
0.135
0.135
0.135
0.135
0.135
Page 7
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A NEMETSCHEK COMPANY Model Name :
Plate Primary Data (Continued)
Label A Node B Node C Node D Node
64 P66 N106 N111 N18 N107
65 P67 N28 N112 N113 N114
66 P68 N114 N113 N115 N116
67 P69 N116 N115 N117 N118
68 P70 N118 N117 N119 N120
69 P71 N120 N119 N121 N122
70 P72 N122 N121 N123 N124
71 P73 N124 N123 N125 N126
72 P74 N126 N125 N127 N25
73 P75 N112 N128 N129 N113
74 P76 N11 3 N129 N130 N115
75 P77 N115 N130 N131 N117
76 P78 N117 N131 N132 N119
77 P79 N119 N132 N133 N121
78 P80 N121 N133 N134 N123
79 P81 N123 N134 N135 N125
80 P82 N125 N135 N33 N127
81 P83 N128 N136 N137 N129
82 P84 N129 N1 37 N138 N130
83 P85 N130 N138 N139 N131
84 P86 N131 N139 N140 N132
85 P87 N132 N140 N141 N133
86 PBB N1 33 N141 N142 N134
87 P89 N134 N142 N143 N135
88 P90 N135 N143 N144 N33
89 P91 N136 N30 N145 N137
90 P92 N137 N145 N146 N138
91 P93 N138 N146 N147 N139
92 P94 N139 N147 N148 N140
93 P95 N140 N148 N149 N141
94 P96 N141 N149 N150 N142
95 P97 N142 N150 N151 N143
96 P98 N143 N151 N20 N144
97 P99 N30 N152 N153 N145
98 P100 N145 N153 N154 N146
99 P101 N146 N154 N155 N147
100 P102 N147 N155 N156 N148
101 P103 N148 N156 N157 N149
102 P104 N149 N157 N158 N150
103 P105 N150 N158 N159 N151
104 P106 N151 N159 N160 N20
105 P107 N152 N161 N162 N153
106 P108 N153 N162 N163 N154
107 P109 N154 N163 N164 N155
108 P110 N155 N164 N165 N156
109 P111 N156 N165 N166 N157
110 P112 N157 N166 N167 N158
111 P113 N158 N167 N168 N159
112 P114 N159 N168 N169 N160
113 P115 N161 N170 N171 N162
114 P116 N162 N171 N172 N163
115 P117 N163 N172 N173 N164
116 P118 N164 N173 N174 N165
117 P119 N165 N174 N175 N166
118 P1 20 N166 N175 N176 N167
RISA-3D Version 21 [Aviara Stairs GARAGE.r3d]
Material
aen Steel
nen Steel
aen Steel
aen Steel
nen Steel
aen Steel
nen Steel
aen Steel
nen Steel
nen Steel
nen Steel
nen Steel
aen Steel
nen Steel
aen Steel
aen Steel
nen Steel
aen Steel
nen Steel
nen Steel
aen Steel
nen Steel
aen Steel
nen Steel
aen Steel
nen Steel
aen Steel
aen Steel
nen Steel
aen Steel
nen Steel
nen Steel
aen Steel
nen Steel
oen Steel
nen Steel
aen Steel
nen Steel
nen Steel
oen Steel
nen Steel
aen Steel
nen Steel
aen Steel
nen Steel
nen Steel
aen Steel
nen Steel
aen Steel
nen Steel
aen Steel
nen Steel
aen Steel
aen Steel
nen Steel
Page 19
3/17/2023
4:58:20 PM
Checked By :
Thickness linl
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
Page8
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A NEMETSC.HEK COMPANY Model Name :
Plate Primary Data (Continued)
Label A Node B Node C Node D Node Material
119 P121 N167 N176 N177 N168 aen Steel
120 P122 N168 N177 N36 N169 oen Steel
121 P123 N170 N29 N178 N171 aen Steel
122 P124 N171 N178 N38 N172 aen Steel
123 P125 N172 N38 N179 N173 oen Steel
124 P126 N173 N179 N180 N174 aen Steel
125 P127 N174 N180 N181 N175 oen Steel
126 P128 N175 N181 N182 N176 aen Steel
127 P129 N176 N182 N37 N177 aen Steel
128 P130 N177 N37 N26 N36 oen Steel
Design Size and Code Check Parameters
Label Max Axial/Bending Chk
Typical
Nodal Loads and Enforced Displacements
No Data to Print...
Member Point Loads
No Data to Print...
Member Distributed Loads (BLC 3 : Ex)
Page 20
3/17/2023
4:58:20 PM
Checked By :
Thickness rinl
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
Max Shear Chk
Member Label Direction Start Maqnitude [k/ft, F, ksf k-ft/ft] End Maonitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %) End Location I/ft, %Y
1 M27 X 0.049 0.049 0 %100
2 M25 X 0.049 0.049 0 %100
3 M26 X 0.049 0.049 0 %100
4 M17 X 0.049 0.049 0 %100
5 M28 X 0.049 0.049 0 %100
6 M18 X 0.049 0.049 0 %100
7 M29 X 0.017 0.017 0 %100
8 M23 X 0.017 0.017 0 %100
9 M32 X 0.017 0.017 0 %100
10 M24 X 0.017 0.017 0 %100
11 M20 X 0.017 0.017 0 %100
12 M30 X 0.017 0.017 0 %100
13 M21 X 0.017 0.017 0 %100
14 M31 X 0.017 0.017 0 %100
15 M22 X 0.017 0.017 0 %100
16 M19 X 0.017 0.017 0 %100
Member Distributed Loads (BLC 4 : Ez)
Member Label Direction Start Maanitude [k/ft F ksf k-ft/ft] End Maanitude [k/ft F ksf k-ft/ft] Start Location [(ft %)1 End Location 11ft, %\'
1 M27 z 0.049 0.049 0 %100
2 M25 z 0.049 0.049 0 %100
3 M26 z 0.049 0.049 0 %100
4 M17 z 0.049 0.049 0 %100
5 M28 z 0.049 0.049 0 %100
6 M18 z 0.049 0.049 0 %100
7 M29 z 0.017 0.017 0 %100
8 M23 z 0.017 0.017 0 %100
9 M32 z 0.017 0.017 0 %100
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d ] Page 9
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A NEMETSCHEK COMPANY Model Name :
Member Distributed Loads (BLC 4 : Ez) (Continued)
Page 21
3/17/2023
4:58:20 PM
Checked By :
Member Label Direction Start Maanitude fk/ft F ksf k-ft/ftl End Maanitude [k/ft F ksf k-ft/ftl Start Location flft %)1 End Location [(ft %)1
10 M24 z 0.017 0.017 0 %100
11 M20 z 0.017 0.017 0 %100
12 M30 z 0.017 0.017 0 %100
13 M21 z 0.017 0.017 0 %100
14 M31 z 0.017 0.017 0 %100
15 M22 z 0.017 0.017 0 %100
16 M19 z 0.017 0.017 0 %100
Member Distributed Loads (BLC 5 : BLC 1 Transient Area Loads)
Member Label Direction Start Maanitude [k/ft F, ksf k-ft/ftl End Maanitude fk/ft F ksf k-ft/ftl Start Location f(ft %)1 End Location f(ft %)1
1 M25 y -0.08 -0.08 7.772e-16 8.392
2 M27 y -0.08 -0.08 1.443e-15 8.392
3 M18 y -0.08 -0.08 3.331e-16 8.392
4 M28 y -0.08 -0.08 6.661e-16 8.392
5 M17 y -0.08 -0.08 1.11e-15 4.091
6 M26 y -0.08 -0.08 0 4.091
7 M20 y -0.025 -0.025 0 4
8 M23 y -0.025 -0.025 1 4
9 M24 y -0.025 -0.025 1 4
10 M29 y -0.025 -0.025 1 3
11 M32 y -0.05 -0.05 1 3
12 M19 y -0.025 -0.025 1.832e-15 4
13 M21 y -0.025 -0.025 1 4
14 M22 y -0.025 -0.025 1 4
15 M30 y -0.025 -0.025 1 3
16 M31 y -0.05 -0.05 1 3
Member Distributed Loads (BLC 6 : BLC 2 Transient Area Loads)
Member Label Direction Start Maanitude fk/ft, F, ksf, k-ft/ftl End Maanitude fk/ft, F, ksf k-ft/ftl Start Location flft, %)1 End Location [(ft, %)'
1 M18 y -0.2 -0.2 3.331e-16 8.392
2 M28 y -0.2 -0.2 6.661e-16 8.392
3 M20 y -0.1 -0.1 0 4
4 M23 y -0.1 -0.1 1 4
5 M24 y -0.1 -0.1 1 4
6 M29 y -0.1 -0.1 1 3
7 M32 y -0.2 -0.2 1 3
8 M19 y -0.1 -0.1 1.832e-15 4
9 M21 y -0.1 -0.1 1 4
10 M22 y -0.1 -0.1 1 4
11 M30 y -0.1 -0.1 1 3
12 M31 y -0.2 -0.2 1 3
13 M25 y -0.2 -0.2 5.551e-16 8.392
14 M27 y -0.2 -0.2 1.221 e-15 8.392
15 M17 y -0.2 -0.2 1.11e-15 4.091
16 M26 y -0.2 -0.2 0 4.091
Member Area Loads (BLC 1 : D)
Node A Node B Node C Node D Direction Load Direction Maanitude fksfl
1 N22 N24 N19 N27 y A-B -0.04
2 N28 N25 N17 N21 y A-B -0.04
3 N19 N18 N29 N28 y A-B -0.04
4 N27 N23 N18 N19 y TwoWav -0.025
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d ] Page 10
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A NEMFTSCHF.K COMPANY Model Name :
Member Area Loads (BLC 1 : D) (Continued)
Node A Node 8 Node C Node D Direction
5 N28 N29 N26 N25 y
Member Area Loads (BLC 2 : L)
Node A Node 8 Node C Node D Direction
1 N27 N23 N18 N19 y
2 N28 N29 N26 N25 y
3 N27 N19 N24 N22 y
4 N19 N18 N29 N28 y
5 N28 N25 N17 N21 y
Basic Load Cases
BLC Description Category Y Gravity
1 D DL -1
2 L LL
3 Ex EU<
4 Ez ELZ
5 BLC 1 Transient Area Loads None
6 BLC 2 Transient Area Loads None
Load Combinations
Description Solve P-Delta BLC Factor
1 D Yes y DL 1
2 L Yes y LL 1
3 D+L Yes y DL 1
4 D + 0.7Ex Yes y DL 1
5 D + 0.7Ez Yes y DL 1
6 D -0.7Ex Yes y DL 1
7 D -0.7Ez Yes y DL 1
8 D + 0.75L + 0.525Ex Yes y DL 1
9 D + 0.75L + 0.525Ez Yes y DL 1
10 D + 0.75L -0.525Ex Yes y DL 1
11 D + 0.75L -0.525Ez Yes y DL 1
12 0.60 + 0.7Ex Yes y DL 0.6
13 0.6D + 0.7Ez Yes y DL 0.6
14 0.60-0.7Ex Yes y DL 0.6
15 0.60-0.7Ez Yes y DL 0.6
16 1.40 y DL 1.4
17 1.2D + 1.6L y DL 1.2
18 1.2D + 0.5L + Ex y DL 1.2
19 1.2D + 0.5L + Ez y DL 1.2
20 1.20 + 0.5L -Ex y DL 1.2
21 1.2D + 0.5L -Ez y DL 1.2
22 0.9D + Ex y DL 0.9
23 0.9D + Ez y DL 0.9
24 0.9D-Ex y DL 0.9
25 0.9D-Ez y DL 0.9
26 1.20 + 0.SL + OmeaaEx y DL 1.2
27 1.2D + 0.SL + OmeaaEz y DL 1.2
28 1.2D + 0.SL -OmeaaEx y DL 1.2
29 1.2D + 0.5L -OmeaaEz y DL 1.2
30 0.9D + OmeaaEx y DL 0.9
31 0.9D + OmeaaEz y DL 0.9
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d )
Load Direction
TwoWa
Load Direction
Two Way
TwoWav
A-8
A-8
A-8
Distributed
16
16
16
16
BLC Factor
LL 1
ELX 0.7
ELZ 0.7
EU< -0.7
ELZ -0.7
EU< 0.525
ELZ 0.525
EU< -0.525
ELZ -0.525
EU< 0.7
ELZ 0.7
EU< -0.7
ELZ -0.7
LL 1.6
EU< 1
ELZ 1
EU< -1
ELZ -1
EU< 1
ELZ 1
EU< -1
ELZ -1
Om*EU< 1
Om*ELZ 1
Om*EU< -1
Om*ELZ -1
Om*EU< 1
Om*ELZ 1
Page 22
3/17/2023
4:58:20 PM
Checked By :
Ma nitude ks
-0.025
Maanitude fksfl
-0.1
-0.1
-0.1
-0.1
-0.1
Area/Member)
5
5
BLC Factor
LL 0.75
LL 0.75
LL 0.75
LL 0.75
LL 0.5
LL 0.5
LL 0.5
LL 0.5
LL 0.5
LL 0.5
LL 0.5
LL 0.5
Page 11
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A l<EMETSCHEK COMPANY Model Name:
Load Combinations (Continued)
Solve P-Delta
32 y
33 y
Load Combination Design
BLC Factor BLC
DL 0.9 Om*ELX
DL 0.9 Om*ELZ
Factor BLC
-1
-1
Page 23
3/17/2023
4:58:20 PM
Checked By :
Factor
Description CD Service Hot Rolled Cold Formed Wood Concrete Masonrv Aluminum Stainless Connection
1 D Yes Yes Yes Yes Yes Yes Yes Yes Yes
2 L Yes Yes Yes Yes Yes Yes Yes Yes Yes
3 D+L Yes Yes Yes Yes Yes Yes Yes Yes Yes
4 D + 0.7Ex 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
5 D + 0.7Ez 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
6 0-0.7Ex 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
7 0-0.7Ez 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
8 D + 0.75L + 0.525Ex 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
9 D + 0.75L + 0.525Ez 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
10 D + 0.75L -0.525Ex 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
11 D + 0.75L -0.525Ez 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
12 0.60 + 0.7Ex 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
13 0.60 + 0.7Ez 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
14 0.60 -0.7Ex 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
15 0.60 -0.7Ez 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
16 1.40 Yes Yes Yes Yes Yes Yes Yes
17 1.20 + 1.6L Yes Yes Yes Yes Yes Yes Yes
18 1.20 + 0.5L + Ex Yes Yes Yes Yes Yes Yes Yes
19 1.20 + 0.5L + Ez Yes Yes Yes Yes Yes Yes Yes
20 1.20 + 0.5L -Ex Yes Yes Yes Yes Yes Yes Yes
21 1.20 + 0.5L -Ez Yes Yes Yes Yes Yes Yes Yes
22 0.90 + Ex Yes Yes Yes Yes Yes Yes Yes
23 0.90 + Ez Yes Yes Yes Yes Yes Yes Yes
24 0.90 -Ex Yes Yes Yes Yes Yes Yes Yes
25 0.90-Ez Yes Yes Yes Yes Yes Yes Yes
26 1.20 + 0.5L + OmeaaEx Yes Yes Yes Yes Yes Yes Yes
27 1.20 + 0.5L + OmeaaEz Yes Yes Yes Yes Yes Yes Yes
28 1.20 + 0.5L -OmeaaEx Yes Yes Yes Yes Yes Yes Yes
29 1.20 + 0.5L -OmeaaEz Yes Yes Yes Yes Yes Yes Yes
30 0.90 + OmeaaEx Yes Yes Yes Yes Yes Yes Yes
31 0.90 + OmeaaEz Yes Yes Yes Yes Yes Yes Yes
32 0.90 -OmeaaEx Yes Yes Yes Yes Yes Yes Yes
33 0.90 -OmeaaEz Yes Yes Yes Yes Yes Yes Yes
Envelope Node Reactions
Node Label X lkl LC Y lkl LC Z lkl LC MX lk-ft LC MY lk-ftl LC MZ [k-ftl LC
1 N34 max 1.806 10 1.958 3 0.017 15 0 15 0 15 0 15
2 min -0.094 12 0.345 12 -1.073 3 0 1 0 1 0 1
3 N35 max 0.089 10 -0.109 15 0.017 14 0 15 0 15 0 15
4 min -0.07 12 -0.857 3 -0.264 8 0 1 0 1 0 1
5 N33 max 1.794 10 2.041 3 1.035 3 0 15 0 15 0 15
6 min -0.098 12 0.357 12 -0.029 13 0 1 0 1 0 1
7 N36 max 0.091 6 -0.05 13 0.26 8 0 15 0 15 0 15
8 min -0.073 12 -0.5 3 -0.026 14 0 1 0 1 0 1
9 N17 max 0.11 14 1.821 3 -0.119 15 0 15 0 15 0 15
10 min -0.11 1 4 0.326 12 -1.164 3 0 1 0 1 0 1
11 N21 max 0.144 14 3.635 3 -0.536 15 0 15 0 15 0 15
12 min -0.144 4 0.647 14 -3.822 3 0 1 0 1 0 1
RISA-30 Version 21 [ Aviara Stairs GARAGE.r3d ] Page 12
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A NEMETSCHFK COMPANY Model Name :
Envelope Node Reactions (Continued/
Node Label X [kl LC Y[kl LC Z [kl LC MX [k-ft] LC
13 N22 max 0.11 14 1.88 3 1.244 3 0 15
14 min -0.111 4 0.336 12 0.133 13 0 1
15 N24 max 0.144 6 3.645 3 3.833 3 0 15
16 min -0.144 12 0.649 14 0.537 13 0 1
17 N39 max -0.048 14 0.279 3 -0.03 15 0 15
18 min -0.576 3 0.034 15 -0.49 3 0 1
19 N40 max -0.109 14 1.54 3 -0.279 15 0 15
20 min -1.267 3 0.285 13 -3.259 3 0 1
21 N38 max -0.111 14 1.447 3 3.229 3 0 15
22 min -1.244 3 0.267 15 0.277 13 0 1
23 N37 max -0.041 14 0.011 15 0.477 3 0 15
24 min -0.548 3 -0.047 9 0.029 13 0 1
25 Totals: max 1.908 6 16.844 3 1.908 15
26 min -1.908 12 3.177 14 -1.908 5
Envelope Beam Deflections
Member Label Soan Location [ft] y' [in]
1 M17 1 max 3.196 -0.001
2 1 min 0 0
3 M18 1 max 2.622 0.001
4 1 min 8.392 0.053
5 M19 1 max 0.083 -0.001
6 1 min 0 -0.004
7 2 max 3.5 0
8 2 min 1 0
9 3 max 4 0
10 3 min 3.542 0
11 M20 1 max 1.5 -0.001
12 1 min 0 0
13 M21 1 max 0.5 0
14 1 min 0 0
15 2 max 3 0
16 2 min 0.542 0
17 3 max 3.75 -0.001
18 3 min 3.042 0
19 M22 1 max 2.875 -0.001
20 1 min 0 0
21 M23 1 max 0.083 -0.001
22 1 min 0 -0.001
23 2 max 3.5 0
24 2 min 1.042 0
25 3 max 4 0
26 3 min 3.542 0
27 M24 1 max 2.917 -0.001
28 1 min 0 0
29 M25 1 max 2.71 0.001
30 1 min 8.392 0.067
31 M26 1 max 1.619 -0.001
32 1 min 0 0
33 M27 1 max 2.885 0.001
34 1 min 8.392 0.054
35 M28 1 max 2.71 0.001
36 1 min 8.392 0.067
37 M29 1 max 0.125 -0.001
38 1 min 0 -0.004
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d ]
Page 24
3/17/2023
4:58:20 PM
Checked By :
MY [k-ftl LC MZ lk-ftl LC
0 15 0 15
0 1 0 1
0 15 0 15
0 1 0 1
0 15 0 15
0 1 0 1
0 15 0 15
0 1 0 1
0 15 0 15
0 1 0 1
0 15 0 15
0 1 0 1
(n) L'/y' Ratio LC
NC 3
NC 1
NC 4
3773 3
NC 1
6632 3
NC 15
NC 1
NC 15
NC 1
NC 3
NC 1
NC 15
NC 1
NC 15
NC 1
NC 8
NC 1
NC 8
NC 1
NC 2
NC 1
NC 15
NC 1
NC 15
NC 1
NC 10
NC 1
NC 13
2999 3
NC 10
NC 1
NC 7
3707 3
NC 15
3004 3
NC 4
6164 3
Page 13
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A NEMETSCHEK COMPA'IY Model Name :
Envelope Beam Deflections {Continued)
Member Label Soan Location fftl
39 2 max 3.5
40 2 min 1
41 3 max 4
42 3 min 3.542
43 M30 1 max 1.375
44 1 min 0
45 M31 1 max 0.625
46 1 min 2
47 M32 1 max 3.333
48 1 min 2
Envelope Beam Deflection Checks
Beam Desian Rule Soan Defl linl Ratio LC Defl linl
1 M17 Tvoical 1 0 NC HOU 0
2 M18 Tvnical 1 0.0009154 NC HOU 0.037
3 M19 Tvoical 1 -3.474e-5 NC 1<DU -0.002
4 2 -1.613e-21 NC HOU -3.39e-21
5 3 -4.406e-5 NC HOU -9.89e-5
6 M20 Tvnical 1 1.084e-19 NC HOU -8.674e-19
7 M21 Tvnical 1 -7.302e-23 NC HOU -3.716e-22
8 2 4.567e-21 NC HOU 9.904e-21
9 3 -0.000527 NC 1<0Ll -0.0009937
10 M22 Tvoical 1 0 NC HOU 0
11 M23 Tvnical 1 4.875e-21 NC HOU 1.052e-20
12 2 8.179e-22 NC HOU 1.969e-21
13 3 -4.612e-5 NC 1rou -0.0001042
14 M24 Tvoical 1 2.168e-19 NC HOU 8.674e-19
15 M25 Tvoical 1 0.021 9627 1<0Ll 0.046
16 M26 Tvoical 1 0 NC HOU 0
17 M27 Tvnical 1 0.0009202 NC HOU 0.037
18 M28 Tvoical 1 0.021 9656 HOU 0.046
19 M29 Tvnical 1 -3.776e-5 NC HOU -0.003
20 2 -2.598e-21 NC 1<DU -5.974e-21
21 3 -4.612e-5 NC 1(0L) -0.0001042
22 M30 Tvoical 1 1.084e-19 NC HOU -6.505e-19
23 M31 Tvoical 1 0 NC HOU -0.008
24 M32 Tvnical 1 0 NC 1<DU -0.008
Envelope A/SC 15TH (360-16): ASD Member Steel Code Checks
v' linl (n) L'/v' Ratio
0 NC
0 NC
0 NC
0 NC
-0.001 NC
0 NC
-0.001 NC
-0.011 4391
-0.001 NC
-0.011 4410
Ratio LC Defl linl
NC 2<LU 0
5484 2fLL\ 0.053
9664 2<LU -0.004
NC 2fLU -5.003e-21
NC 2fLL\ -0.000143
NC 2<LU -6.505e-19
NC 2fLL\ -4.441e-22
NC 2(Lll 1.447e-20
NC 2fLU -0.0009394
NC 2fLL\ -3.469e-18
NC 2<LU 1.54e-20
NC 2(LL\ 2.787e-21
NC 2lLU -0.0001503
NC 2(LL\ 8.674e-19
4356 2<Lll 0.067
NC 2fLL\ 0
5386 2(LU 0.054
4361 2fLU 0.067
8958 2(LL\ -0.004
NC 2fLL\ -8.571 e-21
NC 2fLL\ -0.0001503
NC 2(Lll -6.505e-19
6302 2fLU -0.011
6328 2(LL\ -0.011
Page 25
3/17/2023
4:58:20 PM
Checked By :
LC
15
1
15
1
2
1
12
3
15
3
Ratio LC
NC 3<DL+LU
3773 3<DL+Lll
6632 3<DL+LL\
NC 3<DL+Lll
NC 3<DL+Lll
NC 3fDL+LU
NC 3<DL+Lll
NC 3fDL+LU
NC 3<DL+LU
NC 3<DL+LU
NC 3<DL+LU
NC 3fDL+LU
NC 3(DL+LU
NC 3<DL+Lll
2999 3<DL+LU
NC 3<DL+LU
3707 3lbL+LU
3004 3(DL+Lll
6164 3<DL+LU
NC 3<DL+Lll
NC 3<DL+Lll
NC 3(0L+LU
4391 3<DL+Lll
4410 3<DL+LU
Member Shape Code CheckLodft LC Shear CheckLocfft Dir LC Pnc/om fk Pnt/om lk Mnvv/om lk-ft Mnzz/om lk-ft Cb Eon
1 M17 MC12X10.E 0.055 0 7 0.017 4.091 V 3 41 .181 66.826 0.883 20.838 1 H1-1b
2 M18 MC12X10.f 0.338 8.392 6 0.039 8.392 V 3 28.393 66.826 0.883 20.838 1 H1-1b
3 M19 MC12X10.E 0.317 0 6 0.056 0.5 z 6 41.565 66.826 0.883 20.838 1.62~ H1-1b
4 M20 C8X11.5 0.044 0.5 3 0.023 4 V 11 61 .254 72.647 2.231 17.299 1 H1-1 b'
5 M21 MC12X10.f 0.117 3 3 0.033 3 V 3 41 .565 66.826 0.883 20.838 1.551 H1-1 b
6 M22 C8X11.5 0.025 0.5 4 0.039 0 V 4 61.254 72.647 2.231 17.299 1 H1-1 b
7 M23 MC12X10.f 0.121 1 3 0.036 1 V 3 41.565 66.826 0.883 20.838 1.727 H1-1 b
8 M24 C8X11.5 0.042 2 3 0.048 4 V 8 61.254 72.647 2.231 17.299 1 H1-1 b
9 M25 MC12X10.E 0.384 4.196 4 0.035 8.392 V 3 28.393 66.826 0.883 20.838 1 H1-1b
10 M26 MC12X10.F 0.089 2.045 5 0.017 4.091 V 3 41.181 66.826 0.883 20.838 1 H1-1 b
11 M27 MC12X10.E 0.335 8.392 6 0.039 8.392 V 3 28.393 66.826 0.883 20.838 1 H1-1b
12 M28 MC12X10.F 0.407 4.109 8 0.035 8.392 V 3 28.393 66.826 0.883 20.838 1 H1-1b
13 M29 MC12X10.E 0.31 0 6 0.055 0.5 z 6 41 .565 66.826 0.883 20.838 l.54e H1-1b
RISA-30 Version 21 [ Aviara Stairs GARAGE.r3d ] Page 14
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A NEMET SCH EK COMPANY Model Name :
Envelope AISC 15TH (360-16): ASD Member Steel Code Checks (Continued)
Page 26
3/17/2023
4:58:20 PM
Checked By :
Member Shape Code CheckLocfft LC Shear Checklocfft Dir LC Pnc/om fk PnUom fk Mnvv/om fk-ft Mnzz/om [k-ft Cb Eqn
14 M30 C8X11.5 0.051 0.5 3 0.023 0.5 y 3 61.254 72.647 2.231 17.299 1 H1-1b'
15 M31 C4X7.25 0.084 2.083 3 0.018 3.5 y 3 40.989 45.916 0.969 5.102 1 H1-1b
16 M32 C4X7.25 0.085 2 3 0.017 0.5 V 3 40.989 45.916 0.969 5.102 1 H1-1b
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d] Page 15
ASD Joint Reactions
0.11 1.244 / 0.133 1.806
3.645 / 0.649
Envelope Only Solution
-. -0.576
3•635 / O ~6 7119 / -1 .164
1.821 / 0.326
Reaction and Moment Units are kips and kip-ft {Enveloped)
IIIRISA Orie2 Engineering, Inc.
• ~--• -·· ESY
9 /-1 .267
Page 27
3.229 / 0.277
0-tJI I 0.029
SK-7
Mar 17, 2023 at 04:43 PM
Aviara Stairs GARAGE.r3d
ASD Joint Reactions
Page 28
3.229 / 0.277
Envelope Only Solution
Reaction and Moment Units are kips and kip-ft (Enveloped)
IIIRISA Orie2 Engineering, Inc.
,. ~L-••-· ESY
SK-8
Mar 17, 2023 at 04:43 PM
Aviara Stairs GARAGE.r3d
ASD Joint Reactions
Envelope Only Solution
Reaction and Moment Units are kips and kip-ft (Enveloped)
IIIRISA Orie2 Engineering, Inc.
, " ... u " ESY
Page 29
Landing Anchors to (E) CMU Wall
T = 3,259 lbs
Vx = 1,267 lbs
Vy= 1,540 lbs
SK-9
Mar 17, 2023 at 04:43 PM
Aviara Stairs GARAGE.r3d
IIIRISA
A NEMeTSCHEK COMPANY
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number ASD Joint Reactions Model Name :
Envelope Node Reactions
Node Label X fkl LC Y [kl LC Z [kl LC MX [k-ft
1 N34 max 1.806 10 1.958 3 0.017 15 0
2 min -0.094 12 0.345 12 -1.073 3 0
3 N35 max 0.089 10 -0.109 15 0.017 14 0
4 min -0.07 12 -0.857 3 -0.264 8 0
5 N33 max 1.794 10 2.041 3 1.035 3 0
6 min -0.098 12 0.357 12 -0.029 13 0
7 N36 max 0.091 6 -0.05 13 0.26 8 0
8 min -0.073 12 -0.5 3 -0.026 14 0
9 N17 max 0.11 14 1.821 3 -0.119 15 0
10 min -0.111 4 0.326 12 -1.164 3 0
11 N21 max 0.144 14 3.635 3 -0.536 15 0
12 min -0.144 4 0.647 14 -3.822 3 0
13 N22 max 0.11 14 1.88 3 1.244 3 0
14 min -0.111 4 0.336 12 0.133 13 0
15 N24 max 0.144 6 3.645 3 3.833 3 0
16 min -0.1 44 12 0.649 14 0.537 13 0
17 N39 max -0.048 14 0.279 3 -0.03 15 0
18 min -0.576 3 0.034 15 -0.49 3 0
19 N40 max -0.109 14 1.54 3 -0.279 15 0
20 min -1.267 3 0.285 13 -3.259 3 0
21 N38 max -0.111 14 1.447 3 3.229 3 0
22 min -1.244 3 0.267 15 0.277 13 0
23 N37 max -0.041 14 0.011 15 0.477 3 0
24 min -0.548 3 -0.047 9 0.029 13 0
25 Totals: max 1.908 6 16.844 3 1.908 15
26 min -1.908 12 3.177 14 -1.908 5
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d ]
LC MY [k-ft LC
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
Page 30
3/17/2023
4:43:17 PM
Checked By :
MZ fk-ft LC
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
Page 1
Orie2 Engineering
Structural Engineers
9750 M,,.ma, Road, Su,lo 310
San Diego. CA 92126
Fax-(858) 586-0911
PRECAST CONCRETE TREAD "STEPTREAO" (BY "STEPSTONE")
N.L.
L3X3Xl /4 W/3/4"0 x4_1/2"
Project No. : 158.033-23
PROJECT : Aviara-lFA-Stairs Garage
Page 31
DATE: 3/16/23
BY: ESY
Landing Anchors to (E) CMU Wall
l3X3Xl/4XO' -6
2"LT .WT.CONCRETE
C8Xll.S OVER 10 GA. l
HEADER
,'---,.+--------------'----+--~_::~l:r
CMU WALL
C4X7.25
L3X3Xl/4
W/3/4"0 X 4'1"1/2" NOMINAL EMBEDMENT HILTI KB-TZ£ EXPANSION ANCHORS
(ICC-ESR 4266)
SECTION-2
' ' ' 8 ' L3X3Xl/4~--,-,1 _.1t.-k-'--J~'---'--..1<-.::J"--
W/3/4"0 X 4 1/2" NOMINAL EMBEOMENT HILTI KB-TZ[ EXPANSION ANCHORS
(ICC-ESR 4266)
SECTION-3
T = 3,259 lbs
Vx = 1,267 lbs
Vy = 1,540 lbs
V = ( 1267"2 + 1540"2 )"1/2 = 1,995 lbs
s = 8"
Load reduction factor= 0.5 + ( 8 -4 ) / ( 27 -4 ) x 0.5 = 0.587
Tallow= 0.587 x 3810 x 3 anchors= 6,709 lbs
Vallow = 0.587 x 4090 x 3 an chors= 7,202 lbs
NOMINAL EMBEDMENT , HIL TI KB-TZ2 EXP. ANCHORS 4;tl{r2 EMBEDMENT (ICC-ESR 4266)
T I T allow= 3,259 I 6,709 lbs= 0.49 < 1.0
V /Vallow= 1,995 I 7,202 lbs = 0.28 < 1.0
OK
OK
SECTION-8 T I T allow + V / V allow = 0. 77 < 1. 0 OK
Page 32
TABLE 3A-ALLOWABLE ADHESIVE BOND TENSION LOADS FOR THREADED RODS AND REINFORCING BARS IN THE FACE OF
GROUT-FILLED CONCRETE MASONRY UNITS (POUNDS)1•2•7•8•9•11•12•13
Anchor Load @ Spacing• Edge Distances
Diameter Embedment Critical, Minimum, Critical, Minimum, (inches), or (inches)3 Cc, and Load Reduction Load Reduction
Sc, Sc, Smin Factor at Sm1n 6 Cc, Cmfn Factor at Cm1n 6 Rebar Size (inches) (inches) (inches) (inches)
3/a or No. 3 33/a 1240 13.5 4 0.70 12 4 0.80
1/2 or No. 4 41/2 2035 18 4 0.70 20 4 0.76
5/eor No. 5 55/. 2840 22.5 4 0.50 20 4 0.71
~ 3/4 or No. 6 63/4 3810 27 4 0.50 20 4 0.66
TABLE 3B-ALLOWABLE ADHESIVE BOND SHEAR LOADS FOR THREADED RODS AND REINFORCING BARS IN THE FACE OF
GROUT-FILLED CONCRETE MASONRY UNITS (POUNDS)1-2•7•8•9•10•11•12•13
Spacing• Edge Distances
Anchor Load Load Reduction Factor at Cmin • Embedment Load@ Critical, Minimum, Critical, Minimum, Diameter (inches)' Cc, and Sc, Reduction (inches) Sc, Smln Factor at Ccr Cmin
(inches) (inches) 6 (inches) (inches) Load Load Parallel Smin Perpendicular
to Edge to Edge
3/s or No. 3 33/s 850 13.5 4 1.00 12 4 0.88 1.00
1/2 or No. 4 41/2 1495 18 4 1.00 12 4 0.49 1.00
5/, or No. 5 55/. 2615 22.5 4 0.50 20 4 0.40 0.78
3/4 or No. 6 63/4 4090 27 4 0.50 20 4 0.26 0.60
For SI: 1 inch .= 25.4 mm, 1 lbf = 4.45 N, 1 PSI = 6.89 kPa.
The following footnotes apply to both Tables 3A and 38:
1 All values are for anchors installed in fully grouted concrete masonry with minimum masonry strength of 1500 psi. Concrete masonry units must be light-, medium-,
or normal-weight conforming to ASTM C90. Allowable loads have been calculated using a safety factor of 5. 2 Anchors may be installed in any location in the face of the masonry wall (cell, web, joints). Anchors are limited to one per masonry cell.
Embedment depth is measured from the outside face of the concrete masonry unit.
' The critical spacing, s.,, is the anchor spacing where full load values in the table may be used. The minimum spacing, Sm,,. is the minimum anchor spacing for which
values are available and installation is recommended. Spacing is measured from the center of one anchor to the center of an adjacent anchor. 5 The critical edge distance, c.,., is the edge distance where full load values in the table may be used. The minimum edge distance, c.,1,, is the minimum edge distance
for which values are available and installation is permitted. Edge distance is measured from the center of the anchor to the closest edge (See Figure 2). 6 Load reduction factors are multiplicative; both spacing and edge distance load reduction factors must be considered. 7 Load values for anchors installed at less than Ser and c.,. must be multiplied by the appropriate load reduction factor based on actual edge distance (c) or spacing (s). 8 Linear interpolation of load values between minimum spacing (Smm) and critical spacing (Ser) and between minimum edge distance (cm,,) and critical edge distance
(ccr) is permitted. 9 Concrete masonry thickness must be equal to or greater than 1.5 times the anchor embedment depth. EXCEPTION: the 5/8-inch-and the 3/4-inch-diameter anchors and No.5 and No. 6 reinforcing bars may be installed in minimum nominally 8-inch-thick concrete masonry. 10 When using the basic load combinations in accordance with IBC Section 1605.3.1, tabulated allowable loads must not be increased for seismic or wind loading.
When using the alternative basic load combinations in the 2009 or 2006 IBC Section 1605.3.2 that include seismic or wind loads, tabulated allowable loads may be
increased, or the alternative basic load combinations may be reduced according to Table 2. For the 2015 and 2012 IBC, the allowable loads or load combinations
must not be adjusted.
11 Allowable loads must be the lesser of the adjusted masonry or bond values tabulated above and the steel values given in Table 10. 12 Tabulated allowable bond loads must be adjusted for increased base material temperatures in accordance with Figure 1, as applicable. 13 For combined loading, see Section 4.1.2.
LRFD Joint Reactions
Stringer Anchors to Embed Plate\
T = 5,650 lbs
Vy = 5,376 lbs
Vx = 205 lbs
-0.109 / -1 .267
0.137
0.158 1.835/0.133
I 5.376 I o.649
Stringer Bottom Anchors to (E) Concrete Slab
Vz = 5,634 lbs
Vx = 205 lbs
Envelope Only Solution
5.359 / 0.6~6.119 /-1.717
2.686 I 0.326
Reaction and Moment Units are kips and kip-ft (Enveloped)
IIIRISA Orie2 Engineering, Inc.
··~ ,._,.,M" ESY ~--------1
Page 33
4.76 / 0.277
.068
I I -~jgci I 0.029
'-.
-0.041 / -0.808
• -0.103
SK-10
Mar 17, 2023 at 04:51 PM
Aviara Stairs GARAGE.r3d
IIIRISA
A NEMETSCHEK COMPANY
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name : LRFD Joint Reactions
Envelope Node Reactions
Node Label X [kl LC Y [kl LC Z fkl LC MX [k-ft
1 N34 max 2.638 17 2.886 17 0.017 15 0
2 min -0.11 22 0.345 12 -1.583 17 0
3 N35 max 0.137 20 -0.109 15 0.021 24 0
4 min -0.099 22 -1.267 17 -0.382 17 0
5 N33 max 2.612 17 3.01 17 1.526 17 0
6 min -0.116 22 0.357 12 -0.029 13 0
7 N36 max 0.14 20 -0.05 13 0.366 17 0
8 min -0.103 22 -0.736 17 -0.034 24 0
9 N17 max 0.158 24 2.686 17 -0.119 15 0
10 min -0.158 18 0.326 12 -1 .717 17 0
11 N21 max 0.205 24 5.359 17 -0.536 15 0
12 min -0.205 18 0.647 14 -5.634 17 0
13 N22 max 0.158 24 2.774 17 1.835 17 0
14 min -0.158 18 0.336 12 0.133 13 0
15 N24 max 0.205 20 5.376 17 5.65 17 0
16 min -0.205 22 0.649 14 0.537 13 0
17 N39 max -0.048 14 0.413 17 -0.03 15 0
18 min -0.849 17 0.034 15 -0.722 17 0
19 N40 max -0.109 14 2.27 17 -0.279 15 0
20 min -1.867 17 0.285 13 -4.803 17 0
21 N38 max -0.111 14 2.132 17 4.76 17 0
22 min -1.834 17 0.267 15 0.2.77 13 0
23 N37 max -0.041 14 0.015 25 0.704 17 0
24 min -0.808 17 -0.068 17 0.029 13 0
25 Totals: max 2.726 20 24.833 17 2.726 25
26 min -2.726 22 3.177 14 -2.726 19
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d ]
LC MY [k-ft LC
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
Page 34
3/17/2023
4:51:57 PM
Checked By :
MZ [k-ft LC
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
Page 1
Page 35
LRFD Overstrength Joint Reactions
0.158 1.037 / 0.206
2.675 I 0.976
-0.817 / -3.019
2.669 I 0.973
-0 186 / -0.98
1.331 / 0.49
Envelope Only Solution
Reaction and Moment Units are kips and kip-ft (Enveloped)
IIIRISA Orie2 Engineering, Inc.
ESY
2.803 / 0.44
49
I_ &1~11 0.049
-0.065 / -0.484
-0.103
SK-13
Mar 17, 2023 at 04:56 PM
Aviara Stairs GARAGE.r3d
IIIRISA
A NEMETSCHEK COMPANY
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name : LRFD Overstrength Joint Reactions
Envelope Node Reactions -Overstrenqth or Capacity Limit
Node Label X [kl LC Y [kl LC Z [kl LC MX [k-ft LC
1 N34 max 1.903 28* 1.45 28* 0.01 33* 0 33*
2 min -0.11 30* 0.519 30* -1.083 27* 0 26*
3 N35 max 0.137 28* -0.167 33* 0.021 32* 0 33*
4 min -0.099 30* -0.677 27* -0.281 26* 0 26*
5 N33 max 1.897 28* 1.507 28* 1.063 29* 0 33*
6 min -0.116 30* 0.537 30* -0.028 31* 0 26*
7 N36 max 0.14 28* -0.078 31* 0.282 26* 0 33*
8 min -0.103 30* -0.43 29* -0.034 32* 0 26*
9 N17 max 0.158 32* 1.331 28* -0.186 33* 0 33*
10 min -0.158 26* 0.49 30* -0.98 27* 0 26*
11 N21 max 0.205 32* 2.669 26* -0.817 33* 0 33*
12 min -0.205 26* 0.973 32* -3.019 27* 0 26*
13 N22 max 0.158 32* 1.373 28* 1.037 29* 0 33*
14 min -0.158 26* 0.505 30* 0.206 31* 0 26*
15 N24 max 0.205 28* 2.675 26* 3.026 29* 0 33*
16 min -0.205 30* 0.976 32* 0.819 31* 0 26*
17 N39 max -0.076 32* 0.218 27* -0.049 33* 0 33*
18 min -0.502 26* 0.052 33* -0.443 27* 0 26*
19 N40 max -0.172 32* 1.122 29* -0.442 33* 0 33*
20 min -1 .101 26* 0.428 31* -2.826 27* 0 26*
21 N38 max -0.175 32* 1.054 27* 2.803 29* 0 33*
22 min -1 .072 26* 0.4 33* 0.44 31 * 0 26*
23 N37 max -0.065 32* 0.015 33* 0.431 29* 0 33*
24 min -0.484 26* -0.049 27* 0.049 31* 0 26*
25 Totals: max 2.726 28* 12.128 26* 2.726 33*
26 min -2.726 30* 4.765 32* -2.726 27*
RISA-30 Version 21 [ Aviara Stairs GARAGE.r3d ]
MY [k-ft LC
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
Page 36
3/17/2023
4:57:05 PM
Checked By :
MZ fk-ft LC
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
Page 1
Orie2 Engineering Project No, : 158.033-23
Structural Engineers
9750 M~am.r Road, Surte 310
S... 0..00 CA 92126 PROJECT : Aviara-lFA-Stairs Garage
Fu (858) 586-0911
Stringer Bottom Anchors to (E) Concrete Slab
PRECAST CONCRETE TREAD "STEPTREAD"
(BY "STEPSTONE")
11 GA.
CONC . SLA
MC12X1O.6
STRINGER
L4X3Xl(.4X O'-7" fLLH) W/2 -1/2 '0X 3" NOM NAL EMBED I
4 I L J HILTI KB-TZ2 EXPANSION ANCHORS
(ICC ESR-4266)
,.,
SECTION-1
Concrete design properties:
f c = 4,000 psi
Concrete Slab on Grade Thickness = 5"
Stringer Bottom Anchors to (E) Concrete Slab
Vz = 5,634 lbs
Vx = 205 lbs
I
~
SB ON GRADE W/ #4@18" O/C EA. WY. (C)
OVE PROPERLY PREPARED SUBGRADE -LAP
3'-0" AS REQ'D -SEE GEOTECHNICAL REPORT
-JO~T SLAB PER TYPICAL DETAIL AT 15'-0'
O/CMAX.
~ ....
Page 37
DATE : 3/16/23
BY: ESY
CAP PL 1/4"
co :5 V) . u z ex: 0
...I u u
z
UJ
:E 0 UJ co
:E UJ
3. PROVIDE NORMAL WEIGHT CONCRETE (145 PCF) (U,N.O.) WITH PROVEN SHRINKAGE
CHARACTERISTICS OF LESS THAN 0.055 PERCENT, ATTAINING MINIMUM COMPRESSIVE
STRENGTHS AT 28 DAYS (fc) AS FOLLOWS, UNLESS NOTED OTHERWISE:
COLUMNS .............................................. 5000 PSI
SHEARWALLS ....................................... 5000 PSI
ELEVATED SLABS & BEAMS ................ 5000 PSI
FOUNDATIONS ...................................... 4000 PSI
SLAB ON GRADE ................................... 4000 PSI
METAL DECK FILL. ................................ 3000 PSI L TWT U.N.O.
Page 38
1:115.-1 ----------------------------------H ii ti PROFIS Engineering 3.0.88
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter:
Item number:
Effective embedment depth:
Material:
Evaluation Service Report:
Issued I Valid:
Proof:
Stand-off installation:
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 17, 2023
Kwik Bolt TZ2 -CS 1/2 (2 1/2) hnom3
2210254 KB-TZ2 1/2x3 3/4
h•f.act = 2.500 in., hnom = 3.000 in.
Carbon Steel
ESR-4266
12/17/2021 I 12/1/2023
Design Method ACI 318-19 / Mech
eb = 0.000 in. (no stand-off); t = 0.250 in.
Page:
Specifier:
E-Mail:
Date:
Daniel Fisher
dfisher@orie2.com
9/18/2023
•
Anchor plateR : I, x IY x t = 3.000 in. x 6.000 in. x 0.250 in.; (Recommended plate thickness: not calculated)
Profile:
Base material:
Installation:
Reinforcement:
Seismic loads (cat. C, D, E, or F)
no profile
cracked concrete, 4000, fc' = 4,000 psi; h = 5.000 in.
hammer drilled hole, Installation condition: Dry
tension: not present, shear: not present; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar
Tension load: yes (17.10.5.3 (d))
Shear load: yes (17.10.6.3 (c))
R -The anchor calculation is based on a rigid anchor plate assumption.
Geometry [in.] & Loading [lb, in.lb]
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademar1< of Hilti AG, Schaan
Page 39
1 = i i 5 • 1 _____________________ _
Hilti PROFIS Engineering 3.0.88
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
1.1 Design results
Case
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 17, 2023
Description
Combination 1
2 Load case/Resulting anchor forces
Anchor reactions [lb]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x
1 0 2,819
2 0 2,819
max. concrete compressive strain: -[%o]
max. concrete compressive stress: -[psi]
resulting tension force in (x/y)=(0.000/0.000): O [lb]
resulting compression force in (x/y)=(0.000/0.000): 0 [lb]
103
103
Page:
Specifier:
E-Mail:
Date:
Forces [lb]/ Moments [in.lb]
N = 0; Vx = 205; Vy= 5,634;
M. = 0; My = 0; Mz = 0;
Shear force y
2,817
2,817
Anchor forces are calculated based on the assumption of a rigid anchor plate.
3 Tension load
Load Nu, [lb] Capacity ♦ N0 [lb]
Steel Strength* N/A N/A
Pullout Strength* N/A NIA
Concrete Breakout Failure•• N/A NIA
• highest loaded anchor ••anchor group (anchors in tension)
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Daniel Fisher
dfisher@orie2.com
9/18/2023
Seismic Max. Ulil. Anchor[%]
yes 64
()2
-V
Utilization PN = Nu/♦ N" Status
N/A N/A
N/A N/A
N/A N/A
2
,:,,s.,
Hilti PROFIS Engineering 3.0.88
www.hiltl.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 17, 2023
Fastening point:
4 Shear load
Load V "" [lb]
Steel Strength• 2,819
Steel failure (with lever arm)* N/A
Pryout Strength .. 5,638
Concrete edge failure in direction x-.. 5,634
• highest loaded anchor .. anchor group (relevant anchors)
4.1 Steel Strength
Vsa.eq = ESR value
<I> v., •• 1 ~ v".
Variables
A,0 v [in.2]
0.10
Calculations
V,. 09 [lb)
6,878
Results
V,. 09 [lb)
6,878
refer to ICC-ES ESR-4266
ACI 318-19 Table 17.5.2
futa [psi)
114,004 1.000
<I> steel ~ nonductile
0.650 1.000
<I> V,. 09 [lb)
4,471
Input data and results must be checked for conformity with the existing conditions and for plausibility!
Page:
Specifier:
E-Mail:
Date:
Capacity ♦ V n [lb]
4,471
N/A
11,270
10,304
2,819
PROFIS Engineering ( c ) 2003-2023 Hilti AG. FL-9494 Schaan Hilli is a registered Trademark of Hilti AG, Schaan
Utilization 13v = Vu.'♦ vn
64
N/A
51
55
Page 40
3
Daniel Fisher
dfisher@orie2.com
9/18/2023
Status
OK
N/A
OK
OK
3
1 = i i 5 • • ----------------------Hilti PROFIS Engineering 3.0.88
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 17. 2023
Fastening point:
4.2 Pryout Strength
v cpg = kcp [ (::c:) \j/ ec,N Wed,N 1Vc,N Wcp,N Nb ]
4> v cpg ~vu.
ANc seeACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
1V ec,N
\j/ ed,N
\j/ cp,N
Variables
2
\j/ c,N
1.000
Calculations
ANc [in.2]
86.25
Results
16,100
h01 [in.] ec1 N [in.]
2.500 0.000
Cac [in.] kc
6.750 21
ANco [in.2] IV ec\.N
56.25 1.000
4> concrete <t,seismic
0.700 1.000
Page:
Specifier:
E-Mail:
Date:
ACI 318-19 Eq. (17.7.3.1b)
ACI 318-19 Table 17.5.2
ACI 318-19 Eq. (17.6.2.1.4)
ACI 318-19 Eq. (17.6.2.3.1)
ACI 318-19 Eq. (17.6.2.4.1b)
ACI 318-19 Eq. (17.6.2.6.1b)
ACI 318-19 Eq. (17.6.2.2.1)
ec2 N [in.] c. min [in.]
0.000 8.000
A • fc [psi]
1.000 4,000
Wec2.N \j/ ed.N
1.000 1.000
cf,nonduciile 4> Vcpg [lb]
1.000 11 ,270
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilli AG, FL-9494 Schaan Hilti is a registered Trademark of H1ll1 AG, Schaan
1Vcp,N
1.000
Vu• [lb]
5,638
Page 41
4
Daniel Fisher
dfisher@orie2.com
9/18/2023
Nb [lb]
5,250
4
•=iiS•• Hilti PROFIS Engineering 3.0.88
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 17, 2023
Fastening point:
4.3 Concrete edge failure in direction x-
V cbg = (~:) IV ec.V 1Ved,V IV c.V IV h,V IV parallel,V Vb
~ Vcbg ~ Vua
Ave seeACI 318-19, Section 17.7.2.1, Fig. R 17.7.2.1(b)
IV ec.V
IV ed,V
IV h,V
Variables
c11 [in.]
8.000
10 [in.]
2.500
Calculations
Ave [in.2]
140.00
Results
14,720
c12 [in.] ecv [in.]
0.000
d1 [in.]
1.000 0.500
Avco [in.2] IV ec,V
288.00 1.000
4> concrete 4>seismic
0.700 1.000
Page:
Specifier:
E-Mail:
Date:
ACI 318-19 Eq. (17.7.2.1b)
ACI 318-19 Table 17.5.2
ACI 318-19 Eq. (17.7.2.1.3)
ACI 318-19 Eq. (17.7.2.3.1)
ACI 318-19 Eq. (17.7.2.4.1b)
ACI 318-19 Eq. (17.7.2.6.1)
ACI 318-19 Eq. (17.7.2.2.1a)
IV c,V h0 [in.]
1.000 5.000
fc [psi] 111 parallel,V
4,000 2.000
IVed,V IVh,V
1.000 1.549
4> nonductile ~ v cbg [lb]
1.000 10,304
Input data and results must be checked for confonnity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademarl< of Hilti AG, Schaan
vb (lb]
9,773
Vua (lb]
5,634
Page 42
5
Daniel Fisher
dfisher@orie2.com
9/18/2023
5
i = i i S .-• ----------------------Hilti PROFIS Engineering 3.0.88
www.hilti.com
Company: Orie2 Engineering Inc Page:
Address: Specifier:
Phone I Fax: 18583359452 I E-Mail:
Design: Concrete -Mar 17, 2023 Date:
Fastening point:
5 Warnings
Page 43
6
Daniel Fisher
dfisher@orie2.com
9/18/2023
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered -the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The
proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential
concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout
or pryout strength governs.
Refer to the manufacturer's product literature for cleaning and installation instructions.
For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/
• "An anchor design approach for structures assigned to Seismic Design Category C, D, E or Fis given in ACI 318-19, Chapter 17, Section
17.10.5.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the
case, the connection design (tension) shall satisfy the provisions of Section 17.10.5.3 (b), Section 17.10.5.3 (c), or Section 17.10.5.3 (d). The
connection design (shear) shall satisfy the provisions of Section 17.10.6.3 (a), Section 17.10.6.3 (b), or Section 17.10.6.3 (c)."
Section 17.10.5.3 (b) / Section 17.10.6.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile
yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.10.5.3 (c) / Section 17.10.6.3
(b) waive the ductility requirements and require the anchors to be designed for the maximum tension I shear that can be transmitted to the
anchors by a non-yielding attachment. Section 17.10.5.3 (d) / Section 17.10.6.3 (c) waive the ductility requirements and require the design
strength of the anchors to equal or exceed the maximum tension/ shear obtained from design load combinations that include E, with E increased
by w0.
• Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI
318-19, Section 26.7.
Fastening meets the design criteria!
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilli AG, FL-9494 Schaan Hilli is a registered Trademark of H1lli AG, Schaan
6
Page 44
1:11-;;.1 ----------------------------------Hi It i PROFIS Engineering 3.0.88
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 17, 2023
Fastening point:
6 Installation data
Profile: no profile
Hole diameter in the fixture: dr = 0.562 in.
Plate thickness (input): 0.250 in.
Recommended plate thickness: not calculated
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions for use is
required.
Page:
Specifier:
E-Mail:
Date:
7
Daniel Fisher
dfisher@orie2.com
9/18/2023
Anchor type and diameter: Kwik Bolt TZ2 -CS 1 /2 (2 1 /2)
hnom3
Item number: 2210254 KB-TZ2 1/2x3 3/4
Maximum installation torque: 602 in.lb
Hole diameter in the base material: 0.500 in.
Hole depth in the base material: 3.250 in.
Minimum thickness of the base material: 5.000 in.
Hilti KB-TZ2 stud anchor with 3 in embedment, 1/2 (2 1/2) hnom3, Carbon steel, installation per ESR-4266
6.1 Recommended accessories
Drilling
• Suitable Rotary Hammer
• Properly sized drill bit
Coordinates Anchor [in.]
Anchor
1
2
X
0.000
0.000
y
-2.000
2.000
8.000
8.000
Cleaning
• Manual blow-out pump
,,i. y
1.500 1.500
( I'\ ?
~
1
1.500 1.500
Input data and results must be checked for conformity with the existing conditions and for plausibility!
0 0 ~
~
0 0 0 ,i
0 0 ~
~
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademarl< of Hilti AG, Schaan
Setting
• Torque controlled cordless impact tool
• Torque wrench
• Hammer
0 0 0 ,.;
...
~
X
0 0 0 (")
7
•=iiS•• Hilti PROFIS Engineering 3.0.88
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 17, 2023
Fastening point:
7 Remarks; Your Cooperation Duties
Page:
Specifier:
E-Mail:
Date:
Page 45
8
Daniel Fisher
dfisher@orie2.com
9/18/2023
• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each
case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data
or programs, arising from a culpable breach of duty by you.
Input data and results must be checi<ed for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademar1< of Hilti AG, Schaan
8
Page 46
Orie2 Engineering Project No. : 158.033-23
Structural Engineers
9750 Mlf'llmar Road, Suite 310
San Diego, CA 92126 PROJECT: Aviara-lFA-Stairs Garage DATE: 3/16/23
BY: ESY Fax (858) 586-0911
Stringer Anchors to Embed Plate
TOP OF
CONCRETE SLAB
EMBED PL3/8X8X8 / 4-5/8"0 X 9" HEADED STUDS
SECTI ON -?
PRECAST CONCRETE TREAD "STEPTREAD" (BY "STEPSTONE")
1/4" END PL
TOP OE
::..:, SLAB
N
-r--~----.111,---;
M -----~==llFF:
MC12X1O.6
STRINGER
llGA ANGLE (TYP)
TYP.3
SIDES
PRECAST CONCRETE TREAD "STEPTREAD"
(BY "STEPSTONE")
MC12X1O .6 STRINGER "'f CONC.
L2X2Xl/8
EMBED PL3 /8X8X8 W/ 4-5/8"0 X 9" HEADED STUDS
SECTION-4
TYP.3 SIDES
Stringer Anchors to Embed Plate
T = 5,650 lbs
As-Built Design Criteria for the building is not available.
Concrete design properties:
Vy = 5,376 lbs fc = 3,000 psi (minimum for structural concrete)
Vx = 205 lbs Concrete Slab Thickness= 7.5" (Field Verified by Buildwise)
•=iiS•• Hilti PROFIS Engineering 3.0.84
www.hiltl.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter:
Item number:
Effective embedment depth:
Material:
Evaluation Service Report:
Issued I Valid:
Proof:
Stand-off installation:
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 18, 2023 (1)
AWS D1.1 GR. B 5/8
not available
h0r = 12.000 in.
Hilti Technical Data
-I -
Design Method ACI 318-19 / CIP
eb = 0.000 in. (no stand-off); t = 0.500 in.
Page:
Specifier:
E-Mail:
Date:
l
Page 47
Dan iel Fisher
dfisher@orie2.com
3/18/2023
l
Anchor plateR : Ix x IY x t = 7.500 in. x 8.000 in. x 0.500 in.; (Recommended plate thickness: not calculated)
Profile:
Base material:
Reinforcement:
no profile
cracked concrete, 3000, fc' = 3,000 psi; h = 420.000 in.
tension: present, shear: present; anchor reinforcement: shear
edge reinforcement: > No. 4 bar
R -The anchor calculation is based on a rigid anchor plate assumption.
Geometry [in.] & Loading [lb, in.lb]
X
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG. FL-9494 Schaan Hilti is a registered Trademar1< of Hilti AG, Schaan
•=iiS•• Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
1.1 Design results
Case
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 18, 2023 (1)
Description
Combination 1
2 Load case/Resulting anchor forces
Anchor reactions [lb)
Tension force: (+ Tension, -Compression)
Page:
Specifier:
E-Mail:
Date:
Forces [lb]/ Moments [in.lb]
N = 5,650; V, = 5,376; VY= 205;
M, = 0; My = 0; M, = 0;
Anchor Tension force Shear force Shear force x Shear force y
1 1,412 1,345 1,344
2 1,412 1,345 1,344
3 1,412 1,345 1,344
4 1,412 1,345 1,344
max. concrete compressive strain: -[%o]
max. concrete compressive stress: -[psi]
resulting tension force in (x/y)=(0.000/0.000): 5,650 [lb]
resultLng compression force in (x/y)=(0.000/0.000): 0 [lb]
Anchor forces are calculated based on the assumption of a rigid anchor plate.
3 Tension load
Steel Strength*
Pullout Strength*
Concrete Breakout Failure**
Concrete Side-Face Blowout, direction x-••
Load Nua [lb]
1,412
1,412
5,650
2,825
• highest loaded anchor ••anchor group (anchors in tension)
Input data and results must be checked for conformity with the existing conditions and for plausibility!
51
51
51
51
Capacity ♦ N" [lb]
14,966
15,456
7,058
18,387
PROFIS Engineering ( c ) 2003-2023 Hilti AG. FL-9494 Schaan Hllti is a registered Trademar1< of Hilti AG, Schaan
Seismic
no
i~y
03
t\
Tension
0 1
Utilization PN = N"1/♦ Nn
10
10
81
16
Page 48
2
Daniel Fisher
dfisher@orie2.com
3/18/2023
Max. Util. Anchor[%]
92
0 4
• V .
0 2
Status
OK
OK
OK
OK
2
•=ii59'• Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
3.1 Steel Strength
N,a = A ,e,N futa
qi N,a 2: Nua
Variables
A,. N [in.2)
0.31
Calculations
N .. (lb)
19,955
Results
N,. [lb)
19,955
3.2 Pullout Strength
NpN = \j/ c,p NP
NP = 8 Abrg f0
qi NpN 2: Nua
Variables
1V c,p
1.000
Calculations
N [lb)
22,080
Results
N00 [lb)
22,080
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 18, 2023 (1)
ACI 318-19 Eq. (17.6.1.2)
ACI 318-19 Table 17.5.2
futa (psi]
65,000
4> steel 4> N,a [lb]
0.750 14,966
ACI 318-19 Eq. (17.6.3.1)
ACI 318-19 Eq. (17.6.3.2.2a)
ACI 318-19 Table 17.5.2
Ab, [in.2) A. a
0.92 1.000
~ concrete 4> Nen [lb)
0.700 15,456
Nu• [lb]
1,412
f0 [psi)
3,000
Nua [lb)
1,412
Input data and resulls must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilli AG. FL-9494 Schaan Hilli is a registered Trademark of Hilt, AG, Schaan
Page:
Specifier:
E-Mail:
Date:
Page 49
3
Daniel Fisher
dfisher@orie2.com
3/18/2023
3
•=iiS•• Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 18, 2023 (1)
Fastening point:
3.3 Concrete Breakout Failure
(ANc ) Ncbg = ANcO lj/ ec,N 1Vod,N 1V c,N lj/ cp,N Nb
cj> Ncbg ~ Nua
ANc seeACI 318-19, Section 17.6.2.1 , Fig. R 17.6.2.1(b)
ANcO = 9 h!,
1V oc,N = C +: e~) ~ 1.0
3 h0,
lj/ ed,N : 0.7 + 0.3 ( t~t) ~ 1.0
lj/ cp,N
Variables
12.000
c.c [in.]
Calculations
ANc [in.2]
300.00
Results
Ncbg [lb)
9,410
ec, N [in.]
0.000
kc
16
ANcO [in.2)
1,296.00
4> concrete
0.750
ec2N [in.]
0.000
A. a
1.000
1V ocl,N
1.000
cl> NcbQ [lb]
7,058
Page:
Specifier:
E-Mail:
Date:
ACI 318-19 Eq. (17.6.2.1b)
ACI 318-19Table 17.5.2
ACI 318-19 Eq. (17.6.2.1.4)
ACI 318-19 Eq. (17.6.2.3.1)
ACI 318-19 Eq. (17.6.2.4.1b)
ACI 318-19 Eq. (17.6.2.6.1b)
ACI 318-19 Eq. (17.6.2.2.3)
Ca min [in.) lj/ c,N
2.250 1.000
fc [psi]
3,000
111 ec2,N 1Ved,N
1.000 0.737
Nua [lb]
5,650
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, Fl-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1Vcp,N
1.000
Page 50
4
Daniel Fisher
dfisher@orie2.com
3/18/2023
Nb [lb)
55,121
4
•=fiS~• Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 18, 2023 (1)
3.4 Concrete Side-Face Blowout, direction x-
N,b = 160 c11 ~ "-. ~
N,bg = a g,oup N,b
~ N ,bg ~ N ua
ACI 318-19 Eq. (17.6.4.1)
ACI 31 8-19 Eq. (17.6.4.2)
ACI 318-19 Table 17.5.2
Page:
Specifier:
E-Mail:
Date:
ag,oup = ( 1 + 6 ~a1) see ACI 318-19, Section 17.6.4.2, Eq. (17.6.4.2)
Variables
c11 [in.]
2.250
Calculations
1.296
Results
N ,bg [lb]
24,517
c.2 [in.]
N ,b [lb]
18,913
q> concrete
0.750
Atx [in.2] A..
0.92 1.000
~ N,t,g [lb] N ua edge [lb J
18,387 2,825
Input data and results must be checked for conformity with the existing conditions and for plausibility•
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademar1< of Hilti AG, Schaan
fc [psi]
3,000
s [in.]
4.000
Page 51
5
Daniel Fisher
dfisher@orie2.com
3/18/2023
5
•=iiS~•
Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 18, 2023 (1)
Fastening point:
4 Shear load
Load V ua [lb]
Steel Strength* 1,345
Steel failure (with lever arm)* NIA
Pryout Strength** 5,380
Concrete edge failure in direction **1 NIA
* highest loaded anchor **anchor group (relevant anchors)
1 Shear Anchor Reinforcement has been selected!
4.1 Steel Strength
V,a = A,e V fu1a
(j> V,teel ?. Vu••
Variables
A,.v [in.2
]
0.31
Calculations
V,1 [lb]
19,955
Results
v,. [lb]
19,955
ACI 318-19 Eq. (17.7.1.2a)
ACI 318-19 Table 17.5.2
futa [psi]
65,000
$ steel (j> v,. [lb]
0.650 12,971 1,345
Input data and results must be checked for confonnity with the existing conditions and for plausibilityl
Page:
Specifier:
E-Mail:
Date:
Capacity ♦ V" [lb]
12,971
NIA
13,174
NIA
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a regis1ered Trademark of Hilti AG, Schaan
Utilization 13v = Vu/♦ Vn
11
NIA
41
NIA
Page 52
6
Daniel Fisher
dfisher@orie2.com
311812023
Status
OK
NIA
OK
NIA
6
•=iiS•• Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 18, 2023 (1)
Fastening point
4.2 Pryout Strength
v cpg = kcp [ (:;c:) ljl oc.N 1Ved,N ljlc,N 1Vcp.N Nb ]
ct> v cpg .: v ••
ANc seeACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
ANcO = 9 h!,
'V ec,N = (-k) S 1.0 1 +--3 h81
ljl ed.N
ljl cp,N
Variables
2
111 c.N
1.000
Calculations
ANc [in.2]
300.00
Results
18,820
h01 [in.]
12.000
c.c [in.] ..
ANco [in.2]
1,296.00
~ concrete
0.700
ec1 N [in.]
0.000
kc
16
1V ec1,N
1.000
cf> Vcpg [lb]
13,174
Page:
Specifier:
E-Mail:
Date:
ACI 318-19 Eq. (17.7.3.1b)
ACI 318-19 Table 17.5.2
ACI 318-19 Eq. (17.6.2.1.4)
ACI 318-19 Eq. (17.6.2.3.1)
ACI 318-19 Eq. (17.6.2.4.1b)
ACI 318-19 Eq. (17.6.2.6.1b)
ACI 318-19 Eq. (17.6.2.2.3)
ec2 N [in.] c. m;n [in.]
0.000 2.250
), a fc [psi]
1.000 3,000
ljl ec2.N 1Ved,N
1.000 0.737
v •• [lb]
5,380
5 Combined tension and shear loads, per ACI 318-19 section 17.8
Utilization ~N v [%] Status
0.801 0.408 5/3 92 OK
Input data and results must be checked for conformity wtth the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 H1lti AG, FL-9494 Schaan Hilti is a registered Trademar1< of Hilti AG, Schaan
'Vcp,N
1.000
Page 53
7
Daniel Fisher
dfisher@orie2.com
3/18/2023
Nb [lb]
55,121
7
,:,,s.,
Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete• Mar 18, 2023 (1)
Fastening point:
6 Warnings
Page:
Specifier:
E-Mail:
Date:
Page 54
8
Daniel Fisher
dfisher@orie2.com
3/18/2023
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered -the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The
proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential
concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout
or pryout strength governs.
• For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/
The design of Anchor Reinforcement is beyond the scope of PROFIS Engineering. Refer to ACI 318-19, Section 17.5.2.1 (b) for information
about Anchor Reinforcement.
• Anchor Reinforcement has been selected as a design option, calculations should be compared with PROFIS Engineering calculations.
Fastening meets the design criteria!
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 H1lti AG, FL-9494 Schaan Hilti ,s a registered Trademari< of Hilti AG. Schaan
8
Page 55
i = i i S • • ----------------------Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
7 Installation data
Profile: no profile
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 18, 2023 (1)
Hole diameter in the fixture: d, = 0.687 in.
Plate thickness (input): 0.500 in.
Recommended plate thickness: not calculated
Page:
Specifier:
E-Mail:
Date:
9
Daniel Fisher
dfisher@orie2.com
3/18/2023
Anchor type and diameter: AWS D1 .1 GR. B 5/8
Item number: not available
Maximum installation torque: -
Hole diameter in the base material: -in.
Hole depth in the base material: 12.000 in.
Minimum thickness of the base material: 12.813 in.
Hilti AWS welded headed stud anchor with 12 in embedment, 5/8, Steel galvanized, installation per instruction for use
~ ~ y
3.750 3.750
0 0 0 N
0 3
4 0 0 0 -,i
0 0 ~ ~ ..
ST X
1 ? 0 0 0 -,i
0 0 0 c--.i
2.250 3.000 2.250
Coordinates Anchor [in.)
Anchor X y c_, c •• C-y c.Y
1 -1.500 -2.000 2.250 5.250
2 1.500 -2.000 5.250 2.250
3 -1.500 2.000 2.250 5.250
4 1.500 2.000 5.250 2.250
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG. FL-9494 Schaan H1lti is a registered Trademark of Hilti AG, Schaan
9
,:,,s_, ----------------------------------H ii ti PROFIS Engineering 3.0.84
www.hilti.com
Company: Orie2 Engineering Inc Page:
Address: Specifier:
Phone I Fax: 18583359452 I E-Mail:
Design: Concrete -Mar 18, 2023 (1) Date:
Fastening point:
8 Remarks; Your Cooperation Duties
Page 56
10
Daniel Fisher
dfisher@orie2.com
3/18/2023
Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each
case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data
or programs, arising from a culpable breach of duty by you.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilli AG, FL-9494 Schaan Hilli is a registered Trademar1< of Hilti AG, Schaan
10
Orie2 Engineering
Structural Engmeers
9750 Miramar Road, Surte 310
San O,ego, CA 92126
Fax (858) 586-0911
Project No. : 158.033-23
PROJECT: Aviara-lFA-Stairs Garage
Stairs Railing
HSSl¼ xl¼ xi/s
TOP & BOTTOM 11/z
~VCLR .
r--------
Ll/2 0.0 TUBE
I..O UJ _,
Z M ,-,.H Z _J 0 <{ r-1
_J \..J _,
a.. z N
H UJ V,
UJ 0
V, z
'--J II •
_J 0
UJ • r-
3 16
3/S"BENT ROD @ EA. POST
(PICKET)@ 4" MAX.
POST@ 4 -0 MAX.
MC12X10 .6
STRINGER
SECTION-AB
Rail Post Weld Loading
M = 553 lb-ft= 6,636 lb-in
V = 186 lbs
Page 57
DATE : 3/16/23
BY : ESY
Page 58
Stairs Rail Post Weld
"WELDGRP.xls" Program
Version 2.1
WELD GROUP ANALYSIS
Using the Elastic Method for up to 24 Total Welds
Job Name: Aviara-lFA-Stairs Garage Subject: Weld at Base Plate
Job Number: 158.033-23 Originator: ESY I Checker: I ORO
Input Data:
Number of Welds, Nw =I 4 I 14.0
Weld Coordinates:
Start End 12.0 X1 (in.) Y1 (in.) X2 (in.) Y2 (in.)
Weld #1 0.000 0.000 0.000 1.500
1 10.0 Weld #2 0.000 0.000 1.500 0.000
Weld #3 1.500 0.000 1.500 1.500
Weld #4 0.000 1.500 1.500 1.500 ,§_ 8.0
"' ,_ ,->< --~ 6.0
>-,-
,-4.0
---
--2.0
-----m 0.0
0.0 2.0 4.0 6.0 8.0 10.0 12.0
X-AXIS (in.) -+
--WELD GROUP PLOT
--,---
+Y 1 =Start --2=End
1 2 ----2
~Weld #3 Weld #2
No. of Load Points =I 1 I Weld #1
Load Point Data: 1
Point #1 1 2
X-Coordinate (in.)= 0.750
'-origin
+X --Y-Coordinate (in.)= 0.750 ·-·--Z-Coordinate (in.) = 0.000 +Z ----Axial Load, Pz (k) = 0.00 NOMENCLATURE --Shear Load, Px (k)= 0.00 -Shear Load, Py (k)= 0.19 --Moment, Mx (in-k) = 6.64
Moment, My (in-k) = 0.00 -Moment, Mz (in-k) = 0.00
(continued)
1 of 2 3/20/2023 8:21 AM
Results:
Weld Grouo Prooerties· I: Loads,; C.G. of Weld Groun:
Lw=
Xe=
Ye=
Ix =
ly =
J=
6.000
0.750
0.750
2.25
2.25
4.50
Weld #1
Weld #2
Weld #3
Weld #4
in. L'. Pz = 0.00
in. L'. Px= 0.00
in. L'. Py= 0.19
inAJ L'. Mx= 6.64
inAJ L'. My= 0.00
inAJ L'. Mz = 0.00
Weld Forces k/in.
Fw 1 Fw 2
2.214 2.214
2.214 2.214
2.214 2.214
2.214 2.214
Reauired E70XX Weld Size:
Fw(max) = 2.214 kips/in.
Fillet (leg)= 0.149 in.
Throat (eff) = 0.105 in.
Size of Weld Required = 0.149"
kips
kips
kips
in-k
in-k
in-k
Size of Weld Provided= 3/16" = 0.1875"
Weld Req / Weld Prov = 0.149 / 0.1875 = 0.80 < 1.0
2 of 2
Page 59
"WELDGRP.xls" Program
Version 2.1
OKAY
3/20/2023 8:21 AM
co .... ~ ~
x ~ ....
Cl)
Cl)
I
Envelope Only Solution
IIIRISA 1-0_r_ie_2_E_n_gi_ne_e_ri_ng_,_ln_c_. --,
ESY
Section Set
I en en ......
u, ~
~ X ~ q
SK-1
Page 60
Section Sets
I HSS1 .5"x1 .5"x1/8"
HSS1 .5"x1 .5"x3/16"
. (0 .... <'> X . ""! x ~
Cl)
Cl)
I
Mar 20, 2023 at 08:15 AM
Aviara Stairs GARAGE railin ...
Loads: BLC 2, L 1
Envelope On ly Solution
IIIRISA Orie2 Engineering, Inc.
• •·•"" .•. , i._:E:.:S::.Y:...._ ______ 1
Live Load 1
Page 61
0.05 k/ft
SK-2
Mar 20, 2023 at 08:16AM
Aviara Stairs GARAGE rail in ...
Loads: BLC 3, L2
Envelope Only Solution
II •RISA i_:0::..:r~ie::-2 _E_;ng=--in_e_e_rin_g_, l_nc_._7 ·~· M.•. ESY
Live Load 2 Page 62
SK-3
Mar 20, 2023 at 08:16AM
Aviara Stairs GARAGE railin ...
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A NEMETSCHEK COMPAN'V Model Name :
Model Settinas
Number of Reoorted Sections 5
Number of Internal Sections 100
Member Area Load Mesh Size lin2) 144
Consider Shear Deformation Yes
Consider Torsional Waroina Yes
Annroximate Mesh Size /in) 24
Transfer Forces Between lntersectina Wood Walls Yes
Increase Wood Wall Nailina Caoacitv for Wind Loads Yes
Include P-Delta for Walls Yes
Ootimize Masonrv and Wood Walls Yes
Maximum Number of Iterations 3
Sinale No
Multiole /Ootimum) Yes
Maximum No
Global Axis corresoondina to vertical direction y
Convert Existina Data Yes
Default Global Plane for z-axis xz
Plate Local Axis Orientation Global
Hot Rolled Steel AISC 15th (360-16\: ASD
Stiffness Adiustment Yes /Iterative)
Notional Annex None
Connections AISC 14th (360-10\: ASD
Cold Formed Steel AISI S100-16: ASD
Stiffness Adiustment Yes (Iterative)
Wood AWC NDS-18 / SDPWS-15 ASD
Temoerature < 100F
Concrete ACI 318-19
Masonrv TMS 402-16: ASD
Aluminum AA ADM1-15: ASD
Structure Tvoe Buildina
Stiffness Adiustment Yes (Iterative)
Stainless AISC 14th (360-10\: ASD
Stiffness Adiustment Yes (Iterative)
Comoression Stress Block Rectanaular Stress Block
Analvze usina Cracked Sections Yes
Leave room for horizontal rebar solices /2*d bar soacina) Yes
List forces which·were ianored for desian in the Detail Reoort Yes
Column Min Steel 1
Column Max Steel 8
Rebar Material Soec ASTM A615
Warn if beam-column framina arranaement is not understood No
Number of Shear Renions 4
Reaion 2 & 3 Soacina Increase Increment /in) 4
Code ASCE 7-16
Risk Cateaorv I or II
Drift Cat Other
RISA-3D Version 21 [ Aviara Stairs GARAGE railing.r3d ]
Page 63
3/20/2023
8:17:18AM
Checked By :
Page 1
IIIRISA
A NEMFTSCHEK COMPANY
Company
Designer
: Orie2 Engineering, Inc.
: ESY
Job Number
Model Name :
Model Settinas (Continued)
Base Elevation (ft)
Include the weiaht of the structure in base shear calcs
S, fa)
SD, fa) so. (q)
T <sec)
T Z (sec)
TX <sec)
c,z
c.x
CExo. Z
CExo. X
RZ
RX
OnZ
0.)(
c.z c.x
oz ox
Yes
1
1
1
5
0.02
0.02
0.75
0.75
3
3
1
1
4
4
1
1
RISA-3D Version 21 [ Aviara Stairs GARAGE railing.r3d )
Page 64
3/20/2023
8:17:18AM
Checked By :
Page2
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A. NEMETSCHEK COMPANY Model Name :
Node Coordinates
Label X fftl y [ft]
1 N1 -2612.432742 -4626.405423
2 N2 -2608.891075 -4624.155423
3 N3 -2608.891075 -4620.655423
4 N4 -2605.349409 -4621.905423
5 N5 -2605.349409 -4618.405423
6 N6 -2612.432742 -4622.905423
Hot Rolled Steel Properties
Label E lksil G lksil Nu
1 A992 29000 11154 0.3 0.65
2 A36 Gr.36 29000 11154 0.3 0.65
3 A572 Gr.50 29000 11154 0.3 0.65
4 A500 Gr.B RND 29000 11154 0.3 0.65
5 A500 Gr.B RECT 29000 11154 0.3 0.65
6 A500 Gr.C RND 29000 11154 0.3 0.65
7 A500 Gr.C RECT 29000 11154 0.3 0.65
8 A53 Gr.B 29000 11154 0.3 0.65
9 A1085 29000 11154 0.3 0.65
10 A913 Gr.65 29000 11154 0.3 0.65
Hot Rolled Steel Design Parameters
Label Shaoe Lenath lftl
1 M1 HSS1 .5"x1 .5"x3/16" 3.5
2 M2 HSS1 .5"x1 .5"x3/16" 3.5
3 M3 HSS1 .5"x1 .5"x3/16" 3.5
4 M4 HSS1 .5"x1 .5"x1/8" 8.392
Hot Rolled Steel Section Sets
Label Sha e
1 HSS1 .5"x1 .5"x1/8" HSS1 .5X1.5X1/8"
2 HSS1 .5"x1 .5"x3/16" HSS1 .5X1 .5X3/16"
Design Size and Code Check Parameters
Label
Typical
Node Loads and Enforced Displacements (BLC 3 : L2)
Node Label L, D, M Direction
N6 L Z
Member Point Loads
Page 65
3/20/2023
8:17:18AM
Checked By :
z [ft] Detach From Diaohragm
0
0
0
0
0
0
Densitv fk/ft3l Yield fksil Rv Fu fksil Rt
0.49 50 1.1 65 1.1
0.49 36 1.5 58 1.2
0.49 50 1.1 65 1.1
0.527 42 1.4 58 1.3
0.527 46 1.4 58 1.3
0.527 46 1.4 62 1.3
0.527 50 1.4 62 1.3
0.49 35 1.6 60 1.2
0.49 50 1.4 65 1.3
0.49 65 1.1 80 1.1
Lcomo too fftl Channel Cann a fftl Function
Lbvv NIA N/A Lateral
Lbvv N/A N/A Lateral
Lbvv NIA N/A Lateral
Lbvv N/A N/A Lateral
in4 lzz in4 J in•
0.218 0.325
0.289 0.425
Max Axial/Bending Chk Max Shear Chk
Ma nitude k*s2/ft k*s2*ft
No Data to Print...
RISA-3D Version 21 [ Aviara Stairs GARAGE railing.r3d ] Page 3
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A NEMFTSCHEK COMPANY Model Name:
Member Distributed Loads (BLC 2 : L 1)
Page 66
3/20/2023
8:17:18 AM
Checked By :
Member LabelDirectionStart Ma nitude k/ft, F, ksf, k-ft/ft End Ma nitude k/ft, F, ksf, k-ft/ft Start Location ft, % End Location
1 M4 Z 0.05 0.05 0 %100
Member Area Loads
No Data to Print...
Basic Load Cases
BLC Descriotion Cateaorv Y Gravitv Nodal Distributed
1 D DL -1
2 L1 LL 1
3 L2 LL 1
Load Combinations
Solve P-Delta BLC Factor BLC Factor
Yes y DL 1 2 1
Yes y DL 1 3 1
Load Combination Design
Descri tion Service Hot Rolled Cold Formed Wood Concrete Mason Aluminum Stainless Connection
1 D + L1 Yes Yes Yes Yes Yes Yes Yes Yes Yes
2 D + L2 Yes Yes Yes Yes Yes Yes Yes Yes Yes
Enveloe,e Node Reactions
Node Label X [kl LC Y [kl LC Z [kl LC MX lk-ftl LC MY lk-ftl LC MZ [k-ftl LC
1 N4 max -0.001 2 0.017 2 0.002 2 -0.014 2 -0.026 2 0.001 2
2 min -0.001 1 0.017 1 -0.146 1 -0.447 1 -0.109 1 0.001 1
3 N1 max 0.001 2 0.018 2 -0.087 1 -0.339 1 -0.018 1 -0.001 2
4 min 0.001 1 0.D18 1 -0.148 2 -0.415 2 -0.085 2 -0.001 1
5 N2 max 0 2 0.024 2 -0.054 2 -0.159 2 -0.067 2 0 2
6 min 0 1 0.024 1 -0.186 1 -0.553 1 -0.081 1 0 1
7 Totals: max 0 2 0.059 2 -0.2 2
8 min 0 1 0.059 1 -0.42 1
Enveloe,e Beam Deflections
Member Label Span Location fftl v' linl (n) L'/v' Ratio LC
1 M4 1 max 4.196 0 NC 2
2 1 min 0 0 NC 1
3 2 max 8.392 0 NC 2
4 2 min 4.283 0 NC 1
Enveloe,e Beam Deflection Checks
Beam Desi n Rule S an Defl in Ratio Defl in Ratio Defl in Ratio LC
1 M4 0 NC 0 NC N/A NIA N/A
2 2 0 NC 0 NC NIA NIA NIA
RISA-3O Version 21 [ Aviara Stairs GARAGE railing.r3d ] Page4
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A t,EMETSCHEK COMPANY Model Name :
Envelope A/SC 15TH (360-16): ASD Member Steel Code Checks
Member Shape Code Check Locfft LC Shear Check Lodft DirLC Pnc/om fk
1 M1 HSS1 .5X1 .5X3/16" 0.341 0 2 0.111 3.5 z 2 19.015
2 M2 HSS1 .5X1 .5X3/16" 0.454 0 1 0.113 3.5 z 1 19.015
3 M3 HSS 1.5X 1.5X3/16" 0.368 0 1 0.136 3.5 z 1 19.015
4 M4 HSS1 .5X1 .5X1/8" 0.146 8.392 2 0.077 4.196 z 1 3.237
RISA-3D Version 21 [ Aviara Stairs GARAGE railing.r3d ]
Pnt/om fk Mnvv/om fk-ft
29.54 1.219
29.54 1.219
29.54 1.219
20.584 0.887
Page 67
3/20/2023
8:17:18AM
Checked By :
Mnzz/om fk-ft Cb Eqn
1.219 2.17~ H1-1t
1.219 1 H1-1t
1.219 2.17~ H1-1t
0.887 1.314 H1-1t
Page 5
-0 087 / -0 148
Envelope Only Solution
ASD Joint Reactions
Rail Post Weld Loading
M = 553 lb-ft= 6,636 lb-in
V = 186 lbs
Reaction and Moment Units are kips and kip-ft (Enveloped)
IIIRISA 1-O_r_ie_2_E_n_gi_ne_e_ri_ng_,_ln_c_. ---i
ESY
Page 68
0.002
SK-4
Mar 20, 2023 at 08:17 AM
Aviara Stairs GARAGE raili ...
IIIRISA
A NEM<TSCHEK COMPANY
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name : ASD Joint Reactions
Envelope Node Reactions
Node Label X [kl LC Y [kl LC Z [kl LC MX [k-ftl
1 N4 max -0.001 2 0.017 2 0.002 2 -0.014
2 min -0.001 1 0.017 1 -0.146 1 -0.447
3 N1 max 0.001 2 0.018 2 -0.087 1 -0.339
4 min 0.001 1 0.018 1 -0.148 2 -0.415
5 N2 max 0 2 0.024 2 -0.054 2 -0.159
6 min 0 1 0.024 1 -0.186 1 -0.553
7 Totals: max 0 2 0.059 2 -0.2 2
8 min 0 1 0.059 1 -0.42 1
RISA-3D Version 21 [ Aviara Stairs GARAGE railing.r3d ]
LC MY fk-ft LC
2 -0.026 2
1 -0.109 1
1 -0.018 1
2 -0.085 2
2 -0.067 2
1 -0.081 1
Page 69
3/20/2023
8:18:03AM
Checked By :
MZ [k-ft LC
0.001 2
0.001 1
-0.001 2
-0.001 1
0 2
0 1
Page 1
Orie2 Engineering Project No. : 158.033-23
Structural Engineers
9750 Mwamar Road, SUtte 310
San Diego, CA 92126
Fax C858) ~11
PROJECT: Aviara-lFA-Stairs Garage
Handrail to (E) CMU Wall
t. ' • CMU_ ·~ .~ Ll,l'-----,l'-l_1/_2 Ll/2 0.0 TUBE
~.,. :CLR / HANDRAIL (TYP) WALL ~ • v -/
t. 0 -------------~~~~
•v · •iv-,~ I . ~
7 b,. .~ 7 Ii .-'I
l.J z
H 0 z
:3
• 'O • • I q . . .,-
• V • •I V -
.6 I 0
7 b,. •• ~ 7 cl • . .a
WALL BRACKET o
W/ 3/8"0 X 3" o !-
NOMINAL EMBED j a::: KB-TZ2 EXPANSION N o _ I <I
.I· 0
I
I 3 J J
ANCHOR
(ICC ESR-4266)
EMBEDMENT
SECTION-AC
L = 200 lbs
M = 200 lbs x 2.25" = 450 lb-in
T,M = 450 lb-in / 1.5" = 300 lbs
T = 300 lbs
V = 200 lbs
T allow = 590 lbs
Vallow = 695 lbs
T I T allow= 300 / 590 = 0.51 < 1.0 OKAY
V /Vallow= 200 / 695 = 0.29 < 1.0 OKAY
TIT allow+ V /Vallow= 0.80 < 1.0 OKAY
l.J z
H
V)
0 z
Page 70
DATE : 3/16/23
BY : ESY
TABLE 3-ALLOWABLE TENSILE LOADS FOR CARBON STEEL AND STAINLESS STEEL KB-TZ2
ANCHORS IN THE FACE OF GROUT-FILLED CONCRETE MASONRY WALLS 1•3•4•5•6
Page 71
ALLOWABLE SPACING EDGE DISTANCE
NOMINAL NOMINAL TENSILE Critical Minimum Critical Minimum
ANCHOR EMBEDMENT CAPACITY Spacing, Spacing, Load Edge Edge
DIAMETER AT Sc, AND C c, S c, Sm,.2 Multiplier Distance, Distance,
(INCHES) at Sm1n C c, Cmln
in. {mm) lb {kN) in {mml in {mm\ in Imm\ in lmml
¼ 1¼ (44) 145 (0.6) 6 (152) 0.62
17/s (48) 405 (1.8) 6 (152) 3 (76) 0.49
3/s
3 (76) 590 (2.6) 10 (254) 0.58 12 (305)
2½ (64) 500 (2.2) 8 (203) 0.59
1/2 4 (102)
3¼ (95) 640 (2.8) 13 (330) 0.78 4 (102)
3¼ (83) 890 (4.0) 11 (279) 0.66
% 5 (127)
41/2 (114) 940 (4.2) 16 (406) 0.61
20 (508)
4 (102) 1,245 (5.5) 13 (330) 0.49
¼ 6 (152)
5½ (140) 1,385 (6.2) 19 (483) 0.45
For SI: 1 inch = 25.4 mm, 1 lb = 4.45 N.
TABLE 4-ALLOWABLE SHEAR LOADS FOR CARBON STEEL AND STAINLESS STEEL KB-TZ2
ANCHORS IN THE FACE OF GROUT-FILLED CONCRETE MASONRY WALLS 1•3•4•5•6
ALLOWABLE SPACING EDGE DISTANCE
Load
Multiplier
at Cmln
0.87
0.80
0.93
0.94
1.00
0.96
0.96
0.75
0.82
NOMINAL NOMINAL SHEAR Critical Minimum Critical Minimum Perpendicular Parallel
ANCHOR Edge Edge EMBEDMENT CAPACITY AT DIAMETER
(INCHES)
in. {mm)
¼ 1¼ (44)
17/s (48)
3/s
3 (76)
21/2 (64)
1/2
3¼ (95)
3¼ (83)
sis
4½ (114)
4 (102)
¼
5½ (140)
For SI: 1 inch = 25.4 mm, 1 lb = 4.45 N.
Footnotes for Table 3 and Table 4:
Sc,AND Cc,
lb {kN)
320 (1.4)
585 (2.6)
695 (3.1)
1,045 (4.7)
1,735 (7.7)
2050 (9.1)
1,735 (7.7)
2050 (9.1)
Spacing,
Sc,
in Imm)
6 (152)
6 (152)
10 (254)
8 (203)
13 (330)
11 (279)
16 (406)
13 (330)
19 (483)
Spacing, Load Load Load
Sm,.2 Multiplier Distance, Distance, Direction Direction
at Sm1n Cc, Cmln Factor at Factor at
In fmml in {mm) in {mml Cmln Cmln
1.00 1.00
3 (76)
0.76 0.99
12 (305)
4 (102) 0.50 0.83
0.73 4 (102)
0.36 0.75
5 (127)
0.35 0.85
20 (508)
0.36 0.75
6 (152)
0.35 0.85
'Values valid for anchors installed in face shells of Type 1, Grade N, lightweight, medium-weight, or normal-weight concrete masonry units
conforming to ASTM C90. The masonry units must be fully grouted with coarse grout conforming to 2021 , 2018 and 2015 IBC Section 2103.3,
or 2012 IBC Section 2103.13. Mortar must comply with 2021, 2018 and 2015 IBC Section 2103.2.1, or 2012 IBC Section 2103.9. Masonry
compressive strength must be at least 1,500 psi at the time of anchor installation.
2Loads tabulated are applicable to anchors spaced a critical distance of 4 times the effective embedment. The anchors may be placed at a
minimum spacing, Sm1n, provided that reductions are applied to the tabulated values.
3Anchors must be installed a minimum of 13/s inches from any vertical mortar joint in accordance with Figure 4.
'Embedment depth must be measured from the outside face of the concrete masonry unit.
5For intermediate edge distances, allowable loads may be determined by linearly interpolating between the allowable loads at the two
tabulated edge distances.
6The tabulated allowable loads have been calculated based on a safety factor of 5.0.
Page 72
Orie2 Engineering Project No. : 158.033-23
Structural Engineers
9750 M.-amar Road, Surte 310
San Ooogo, CA 92126 PROJECT: Aviara-lFA-Stairs Garage DATE : 3/16/23
BY : ESY Fax (858) 586-0911
3 16
Ll/2 O.D TUBE
CANE RAIL
SECTION-AD
REF: 13/GAS.ll
EMBED PL3/8X9X9 ~v/ 4-1/2"0 X 4" HEADED STUDS
LRFD Load Combination 1.2D + 1.6L
1.6L = 1.6 x 200 lbs = 320 lbs
M = 320 lbs x 42" = 13,440 lb-in
V = 320 lbs
3 16
HSS11/z x11/2 X3 16
POST
SECTION-AF
EMBED PL3 /8X9X9 W/ 4-1/2"0 X 4" HEADED STUDS
1 : i i S • • ----------------------
Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter:
Item number:
Effective embedment depth:
Material:
Evaluation Service Report:
Issued I Valid:
Proof:
Stand-off installation:
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 20, 2023
AWS 01.1 GR. B 1/2
not available
her= 4.000 in.
Hilti Technical Data
-I -
Design Method ACI 318-19 / CIP
eb = 0.000 in. (no stand-off): t = 0.375 in.
Page:
Specifier:
E-Mail:
Date:
l
Page 73
Daniel Fisher
dfisher@orie2.com
8/10/2023
l
Anchor plateR : I, x Iv x t = 9.000 in. x 9.000 in. x 0.375 in.: (Recommended plate thickness: not calculated)
Profile:
Base material:
Reinforcement:
no profile
cracked concrete, 3000, fc' = 3,000 psi; h = 7.500 in.
tension: not present, shear: not present;
edge reinforcement: none or < No. 4 bar
R -The anchor calculation is based on a rigid anchor plate assumption.
Geometry [in.] & Loading [lb, in.lb]
4 I
X
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Page 74
•=iiS~• --------------------------------Hi It i PROFIS Engineering 3.0.87
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
1.1 Design results
Case
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 20, 2023
Description
Combination 1
2 Load case/Resulting anchor forces
Anchor reactions [lb]
Tension force: (+ Tension, -Compression)
Anchor Tension force Shear force Shear force x
2
3
4
1,084
166
1,084
166
80
80
80
80
80
80
80
80
max. concrete compressive strain: 0.07 (%o]
max. concrete compressive stress: 312 [psi]
resulting tension force in (x/y)=(-1.470/0.000): 2,500 (lb]
resulting compression force in (x/y)=(3.907/-0.000): 2,500 [lb]
Page:
Specifier:
E-Mail:
Date:
Forces [lb]/ Moments [in.lb]
N = 0; V, = 320; VY= 0;
M, = 0; My= 13,440; Mz = 0;
Shear force y
0
0
0
0
Anchor forces are calculated based on the assumption of a rigid anchor plate.
3 Tension load
Steel Strength•
Pullout Strength*
Concrete Breakout Failure••
Concrete Side-Face Blowout, direction ••
Load Nu• [lb]
1,084
1,084
2,500
NIA
• highest loaded anchor **anchor group (anchors in tension)
Input data and results must be checked for conformity with the existing conditions and for plausibility!
Capacity ♦ N" [lb]
9,555
9,895
5,293
N/A
PROFIS Engineering ( c) 2003-2023 Hilti AG. FL-9494 Schaan Hilti IS a registered Trademark of Hilti AG, Schaan
Seismic
no
A~ y
03
®
Tension
01
Utilization 13N = Nu.f♦ N"
12
11
48
NIA
2
Daniel Fisher
dfisher@orie2.com
8/10/2023
Max. Util. Anchor[%]
48
t
04
• V ® ~
Compres ion
02
I
Status
OK
OK
OK
NIA
2
i = i i S • i ______________________ _
Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
3.1 Steel Strength
Nsa = A,e.N futa
cj> N .. ;,: Nua
Variables
A,. N [in.2]
0.20
Calculations
N,a [lb]
12,740
Results
N,. [lb]
12,740
3.2 Pullout Strength
NpN = ~I c,p Np
NP = 8 Abrg fc
cj> NpN ;,: Nua
Variables
111 c,p
1.000
Calculations
N [lb]
14,136
Results
N00 [lb]
14,136
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 20, 2023
ACI 318-19 Eq. (17.6.1.2)
ACI 318-19 Table 17.5.2
fu1a [psi]
65,000
cj> steel cl> N,a [lb]
0.750 9,555
ACI 318-19 Eq. (17.6.3.1)
ACI 318-19 Eq. (17.6.3.2.2a)
ACI 318-19Table 17.5.2
Ab, [in.2] A a
0.59 1.000
4>. concrete cl> N00 [lb]
0.700 9,895
1,084
f0 [psi]
3,000
Nua [lb]
1,084
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Page:
Specifier:
E-Mail:
Date:
Page 75
3
Daniel Fisher
dfisher@orie2.com
8/10/2023
3
•=iiS•• Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 20, 2023
Fastening point:
3.3 Concrete Breakout Failure
(ANc ) Ncbg = A ljl ec,N ljl ed,N 'V c,N \j/ cp,N Nb NcO
$ Ncbg <! Nua
ANc seeACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
ANcO = 9 h!,
\j/ ec.N = ( 1+ ~ e~) s 1.0
3 h01
\j/ ed,N = 0.7 + 0.3 ( t•s~:,) S 1.0
\j/ cp,N
Variables
4.000
c,c [in.]
Calculations
ANc [in.2]
156.25
Results
Nebo [lb)
7,562
ec1 N [in.]
1.470
kc
24
ANcO [in.2]
144.00
<I> concrete
0.700
ec2 N [in.)
0.000
"-a
1.000
1V ec1.N
0.803
$ Ncba [lb]
5,293
Page:
Specifier:
E-Mail:
Date:
ACI 318-19 Eq. (17.6.2.1b)
ACI 318-19 Table 17.5.2
ACI 318-19 Eq. (17.6.2.1.4)
ACI 318-19 Eq. (17.6.2.3.1)
ACI 318-19 Eq. (17.6.2.4.1b)
ACI 318-19 Eq. (17.6.2.6.1 b)
ACI 318-19 Eq. (17.6.2.2.1)
c. min [in.) \j/ c.N
2.500 1.000
( [psi]
3.000
1Vec2,N lj/ ed,N
1.000 0.825
Nua [lb]
2,500
Input data and results must be checked for conformity with the existing conditions and for plausibili1yl
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilt, AG, Schaan
'Vcp,N
1,000
Page 76
4
Daniel Fisher
dfisher@orie2.com
8/10/2023
Nb [lb]
10,516
4
•=iiS~• Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 20, 2023
Fastening point:
4 Shear load
Load V ua [lb]
Steel Strength• 80
Steel failure {with lever arm)' N/A
Pryout Strength .. 320
Concrete edge failure in direction y ... 320
• highest loaded anchor .. anchor group {relevant anchors)
4.1 Steel Strength
V,a = A,e.V futa
tj> V,teel <?. Vua
Variables
A,.v [in.2
]
0.20
Calculations
V,a [lb]
12,740
Results
v,. [lb]
12,740
ACI 318-19 Eq. (17.7.1.2a)
ACI 318-19 Table 17.5.2
futa [psi]
65,000
tj> steel ti> V,a [lb]
0.650 8,281 80
Input data and results must be checked for conformity with the existing conditions and for plausibility!
Page:
Specifier:
E-Mail:
Date:
Capacity ♦ Vn [lb]
8,281
N/A
13,180
3,108
PROFtS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Utilization 13v = V ua/♦ vn
1
N/A
3
11
Page 77
5
Daniel Fisher
dfisher@orie2.com
8/10/2023
Status
OK
N/A
OK
OK
5
Page 78
1:115;.1 ----------------------------------Hilt i PROFIS Engineering 3.0.87
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 20, 2023
Fastening point:
4.2 Pryout Strength
V cpg = kcp [ (::c:) \jl ec.N \jl ed,N \jl c,N \jl cp,N Nb ]
<I> v cpg ~ v u.
ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1 (b)
\jl ec,N
\jl ed,N
IV cp.N
Variables
2
ljl c,N
1.000
Calculations
ANc [in.2]
156.25
Results
18,828
h8r [in.)
4.000
c.c [in.]
ANco [in.2]
144.00
4> concret•
0.700
ec1 N [in.]
0.000
kc
24
1V ec1,N
1.000
4> Vcoo [lb]
13,180
Page:
Specifier:
E-Mail:
Date:
ACI 318-19 Eq. (17.7.3.1b)
ACI 318-19 Table 17.5.2
ACI 318-19 Eq. (17.6.2.1.4)
ACI 318-19 Eq. (17.6.2.3.1)
ACI 318-19 Eq. (17.6.2.4.1b)
ACI 318-19 Eq. (17.6.2.6.1b)
ACI 318-19 Eq. (17.6.2.2.1)
ec2N [in.) C1 mon [in.)
0.000 2.500
A• fc [psi]
1.000 3,000
\jl ec2,N \jl ed,N
1.000 0.825
Vu• [lb]
320
Input data and results must be checked for conformity with the existing conditions and for plausibili1yl
PROFIS Engineering ( c) 2003-2023 Hilt, AG, FL-9494 Schaan Hilti is a registered Trademark of Hilt, AG, Schaan
\jl cp,N
1.000
6
Daniel Fisher
dfisher@orie2.com
8/10/2023
Nb [lb]
10,516
6
i = i i 5 • • ----------------------Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 20, 2023
Fastening point:
4.3 Concrete edge failure in direction y-
(Ave ) V cbg = Avco IV ec,V 1Ved,V IV c,V IV h,V 1v parallel.V v b
$ Vcbg <:: Vua
Ave see ACI 318-19, Section 17.7.2.1, Fig. R 17.7.2.1(b)
Avc0 = 4.5 c!,
IV ec,V = (, + ~) ~ 1.0
1.5c01
IV ed,V = 0.7 + 0.3( 1 _~~
81
) ~ 1.0
1Vh,V = #;:: 1.0
a
( (
I 0.2 )
= 7 t.) ~
Variables
c., [in.]
2.500
10 [in.]
4.000
Calculations
Ave [in.2]
38.44
Results
4,440
c02 [in.]
2.500
A. a
1.000
Avco [in.2]
28.12
tf, concrete
0.700
ecv [in.]
0.000
d0 [in.]
0.500
IV ec.V
1.000
$ Vct>o [lb]
3,108
Page:
Specifier:
E-Mail:
Date:
ACI 318-19 Eq. (17.7.2.1b)
ACI 318-19 Table 17.5.2
ACI 318-19 Eq. (17.7.2.1.3)
ACI 318-19 Eq. (17.7.2.3.1)
ACI 318-19 Eq. (17.7.2.4.1b)
ACI 318-19 Eq. (17.7.2.6.1)
ACI 318-19 Eq. (17.7.2.2.1a)
IV c.V h0 [in.]
1.000 7.500
fc [psi] ~I parallel,V
3,000 2.000
IV ed,V IVh,V
1.000 1.000
Vu• [lb]
320
5 Combined tension and shear loads, per ACI 318-19 section 17.8
I:, Utilization 13N v [%] Status
0.472 0.103 5/3 31 OK
Input data and results must be checked for conformity wi1h the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademarl< of Hilti AG. Schaan
Vb [lb]
1,624
Page 79
7
Daniel Fisher
dfisher@orie2.com
8/10/2023
7
•=iiS~•
Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 20, 2023
Fastening point:
6 Warnings
Page:
Specifier:
E-Mail:
Date:
Page 80
8
Daniel Fisher
dfisher@orie2.com
8/10/2023
The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021 , ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered -the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The
proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential
concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout
or pryout strength governs.
• For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/
Fastening meets the design criteria!
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG. FL-9494 Schaan Hilti is a registered Trademark of Hilli AG, Schaan
8
Page 81
i = i i S • i _____________________ _
Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 20, 2023
Fastening point:
7 Installation data
Profile: no profile
Hole diameter in the fixture: d1 = 0.562 in.
Plate thickness (input): 0.375 in.
Recommended plate thickness: not calculated
Page:
Specifier:
E-Mail:
Date:
9
Daniel Fisher
dfisher@orie2.com
8/10/2023
Anchor type and diameter: AWS 01 .1 GR. B 1 /2
Item number: not available
Maximum installation torque: -
Hole diameter in the base material: -in.
Hole depth in the base material: 4.000 in.
Minimum thickness of the base material: 4.813 in.
Hilti AWS welded headed stud anchor with 4 in embedment, 1/2, Steel galvanized, installation per instruction for use
n Y
4.500 4.500
0
0 I{)
N
0 0
0 3
.,,. I{)
.f
0 0 -0 .. .f X
1 ? 0 0 "' .f
0 0 ": N
2.500 4.000 2.500
Coordinates Anchor [in.]
Anchor X y c .• c •• c.y c.Y
1 -2.000 -2.000 2.500 2.500
2 2.000 -2.000 6.500 2.500
3 -2.000 2.000 2.500 6.500
4 2.000 2.000 6.500 6.500
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilli AG, Schaan
9
1:115;.1
Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 20, 2023
Fastening point
8 Remarks; Your Cooperation Duties
Page:
Specifier:
E-Mail:
Date:
Page 82
10
Daniel Fisher
dfisher@orie2.com
8/10/2023
Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each
case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data
or programs, arising from a culpable breach of duty by you.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Enginee,ing ( c) 2003-2023 Hilt, AG. FL-9494 Schaan Hilt, is a registered Trademark of Hilti AG, Schaan
10
C'
)
co
Q)
C)
l1
l
Q.
n ~,
,
[! ~:
i
0
-
_;
_:
,-
'
'-
'
,
C-
-
--
+
-
,
,_
.
_
,
,
_
.
.
.
.
_
,
_
-
'
-
'
-
-
_
__
,
_
,
.
.
_
_
,
0-
!
0·
' 0
~ i~
I
,.•
0
-
_ _;
,.
,
-
J
.
.
.
.
.
,
.
i
-
-
4
-
,
'
-
-
l
-
"
'
-
'
4
-
+-
.
;
.
+
-
-
-
-
+
'
'-
-
'
~
0-
t 'l
;
I
I
!1
,.
!1
0·
0
I
I
I
I
-H
-n
!1
!t
I
_,
_
-
-
i
-
-
-
"
-
-
-
+
-
.
.
-
-
-
-
i
-
l
!
□-T
I 0
.L
i
.
,,
I I I
~
,4
.·••
t
.
•
"·
jj
14
1
I
I
.,,
,
I
'
•.
I
I
!(
i
,
,
:•.\
i
i
-·
-
H
'
r·~
·.
:
I
!
0
€)
i!
:
If
1,
ii
~
0 0
i
j
-
--
·-
,-•
.
.
.
-
•
-
i
0-
fi
b;
"
'
ii
I
I
~.
~
,,
'
"
@)
-
_;
_:
.-
-
'
1
-
-
1
.
-
;
'
-
-
'
l
'
-
,
'
-
'
"
-
'
l
-
+
+
-
i
-
-
;
.
.
.
.
.
.
-
..
.
µ
_
.
:
.
.
:
,
0-
1
0·
I
I
''
I
I
I
I
I
I
+-
+
-
-
-
-
"
-
-
+
-
+
-
-
-
i
a
,
□-
r
i!
;
I
;:
=
.
:
=
=
=
=
==
=
::
;
;
=
=
=
=
:
;
:
=
=
=
=
::
.
'
"
-
!
' 0
~---·
~-
~-
t
{e}
1 -~r_ __
~
'f
ip_ __
~-
·~ !~
APPROVER NOTE·
-f,'Z.~
VERIFICATION IS REQ'D AT ALL 0IM£NSI0NS :riiMl~~fh:CIN~~r11~F sl&.
SEmON A-A
; l -·-·---~
.
~:; if-
1-1·= ·1--. _ ./3)_ ., 'y'
: 'If -~J ~! ~= ~ .. :· ____ _
-~ t~ ' !~ .
r~ i·--~
1] l~t J ~l
ji t .. ~J~
~-
~
~---
~
! ,,i ,;..-11. rl
I I -·-~ ~; __ -~-' . ..J·----'------;;,n,
~ffe
[·-·--~
1------~
., ;i -~
r4-~
; ~:J!. ;_ -··:1 : /Ii.I(..
1]
-~
~ f_
~
t
~-
~! t
::-I~-• ~~ 2 ""' ... ~-.J~~----·····-L.--.-·-· -
~]
--~
-~"""
"'
~ffe
SEmON B-B -.....-n,-cr--
I JSSUCO f(a "'"'1<1N.
Of.SOtmON I Ol/2J/l31
~
l I ~I
'.f
1i J : ~-
--__ i
--~
~i
,_:j]
-d . ji
di ____ J
BUILDWISE INC.
1800 J<tlN TOWlRS AVUIUE, U (AJON, CA. 92010 l'MONE cut> na-uoo" oso su-1021
~-
{t
~
{l
~-
~--· ~-•-;
r,.;;."i'" i
~ n~
~! ,-~! i
Page 84
.. ...;; l :~ ¥
:---~
~ ~-! i.J
J
:--~
31 in, : ir
... ,
' -· ·---~
-~ ! J~
fl:~ ,.!!',,. m ,:n!s
, ~L-~ -
---·-·
~
nQJ£CT:
-~·
.. ~\ ~·
.E:311
! i : ~ .... ~-r------~;~-
i:,.,-
J -t~--~
H-,--/ ~-! • '! : l ~
·~
i--•.t . . ~;~,~:::·_:r: -l--~1i
SECTION C-C
~ AVIARA -PAIUC.INC STRUCT\JRE (c.A.RAC.E) STAllt fl • caoss SECTION
LOCAtfON: OllAlinrl: VW JOI Jllo: 1600
CARLSIAO, CA O.Tt: 02_{15/23 OMWIPC. Nl .. U. ~
COHTAACTOI:: ~ WERMERS Co. 02/15/U MEG101 A
"'
co
(I
)
0)
ro
0..
0-
-
--
0
--
-
--
-
0-
·
-
H
..
,.
!
I
.,
$
..
,.
.
,
1 $
€>
'
:J
,
l
~
;
Ci
i
,,
....
1
11
l,
J
;,
•
. .
~
0
0--
-
-
0
--
__
_
j
0-
-
I
I
I
I
I
I
I
I
;i
i
·-~
Ji
~
·-
0
0--
-
-
-
0
I 11
.l
~-0
I
I
1!
I
1!
I
1!
11
!
I
! i !
•·:
.
__
_
_
_
i __
_
_
___
_
I
i
~
"'
';
;
_,,
t
l
°
I $
I
•.t
~
"'
:
,,I
0
~
.. ,
I
I··
..
:u
-
-
!1
I
!1 I
!1
I
!'
I
i
ii
·
•
~
!
.
~w
i
'2
~
~~
J!
,
.
.
.
-0
ai
i
:
J
~~
!
;
oi
l
;
~j
~-
!~
i:
~
:l
~
0
=~
!
i~
l
~--
7--,
t
~-
i a:_·j 1 ~ ~ --:::, " v ·---~
t
~--<·-·
t
~·
;r;
't
APPROVER NOTE i
r.,.,:o
V[IUFICATJON .IS REQ'D AT All Ot~(kSIONS ~PiMEs=ri~fh~l~'Otllrr~F sl&.
SEmON A-A
.,_.r ....
11:,'f
-·-~
' ]1
-;--·-~
t~=j' i'~~
~]
;-~--~ = '.l •
-t,-' • ~I
--~ ____ }P
1/J
;·-·-L.h f~' v t
·• l; ~! ~ ___ }l~
~! J
'Of )fUl O,lil ....... 0◄"} n,.11.11
~1:'M1,\mS.U!'lf.-G40tl '": ~ Of OWINU.C0U,NII CUTU llNt: £ fA(f OJ F'[<flSM
~·-
•5"' ,-,i ,;--
i i ! t lf j
I I -:::,, ~! hi •
~~
~·
r,
1F:
~·
~
'-··
~·
~·-<·-·-•·
'I! !f
---~--
l-----"'"'-----1-------::.;..
SECTION 8-8
,. I ISSUED ~OI: JJ'l'IIO','Al
OESOJll'TION
~, ...
•.L-j
ioini7i"i ~
ll'/.-
·-·-·-~
1----~
~I
~-
---1--~'
ii t __ :r
-~
I ~! J! ~---~'
tj]
J -~
~
' J ___ ..,.._
~! j
-~
~
··-1·-~?
BUILDWISE INC.
1800 ~~ TM.as A\IOIJE, E.L CAJON, (A. 92010 l'tQI£. ('19) 3'1·1100 & CSSI} SSJ-1029
>!-• !,_._, ...... i
~·
"~·· -:_ < • ' .
;;f'---;;-; !
Page 86
\ ' -l ----.L3::\.
{JJ-·······.1~ -·-1 . "'" :::J::·"" ~-::-··-• • •
~ -~'.I v
-1/ ~i ·--i----~1~
~·
.....,,.,
•·-"'.·· • ·4 i
t ·
~~·
~·
r ·
~· ~~
J -l: ~,--~
ll?~J
J
--·-~ ~ . ,
I
r:' ~;
:r-.. ~_.J
·-+-·'
·~·!-~ ,r:
~~-· ';;J~l•-·-·=---== ~ !
i 1~-
-~I ip
~ ;~~
,, ~!
.. ,-1
SECTION C-C
PIIOJECT· ~
~:~:-PAR~H«, STRUCTURE {c.,A.RA.c.EJ I ~~~_'1 .-... caoss s~~~ I
CAIi.LS.BAO, (A 02/1\/21
~_Mo:
~..c11t..,.u.
1600
«.ITAACTOlt:
WERMERS Co. OflC'D: ~ ~ 02/1\/23 MEG201 I A
Orie2 Engineering
Structural Engineers
9750 Miramar Roao. Suite 310
San Diego, CA 92126
Fax: (858) 586-0911
RESPONSE TO PLAN REVIEW COMMENTS
September 18, 2023
PROJECT: Aviara-lFA-Stairs -Garage
Our responses to the Structural Plan & Calculation Review Comments are as follows:
Comment
S2
S3
Structural Comments & Responses
Response
Comment: Regarding section-1 , Address the following comments:
a) Please specify the existing slab thickness and concrete strength
to ensure that the input data in Hilti software are correct.
b) Please specify the edge distance on hilti report.
c) Please revise to show and include the tension force.
Response:
a) The concrete compressive strength is f'c = 4,000 psi for slabs on
grade. The thickness of the slab is 5" thick. Calculations revised,
and as-built excerpts included accordingly. See calculation pages
37-45.
b) Per As-Builts, anchor edge distance is a minimum of 8".
Calculations revised to reflect edge distance. See calc pgs. 37-45.
c) The 5,359 lbs / 647 lbs reaction force are both compressive
forces bearing on concrete. There is no tension on these anchors
under any load combination.
Comment: On page 46 at the structural calculation, please revise the
slab thickness and show it in the section.
Response: The 420 inches is not the slab thickness. The slab thickness
is 7.5 inches, and the 420 inches represents a long enough length of the
slab (where people walk on it). In reality this length is longer than 420
inches, but this arbitrary length is sufficient for anchor calculations.
Orie2 Engineering
Structural Engineers
9750 Miramar Road. Suite 310
San Diego, CA 92126
Fax: (858) 586-0911
Structural Calculations
PROJECT: Aviara-lFA-Stairs Garage
(Project # 158.033-23 )
CLIENT: PCIW
DESIGNED BY:
ESY
DATE:
8/10/23
PREV2023-0167
1205 AVIARA PKWY
Orie2 -Structural Engineers
AVIARA APARTMENTS: DEFERRED STAIR SUBMITTAL
DEV201 7-0033 2120405600
CBC2021-0489 8/21/2023
PREV2023-0167
CITY
Orie2 Engineering
Structural Engineers
9750 Miramar Road, Suite 310
San Diego, CA 92126
Fax: (858) 586-0911
Structural Calculations -Table of Contents
Aviara-lFA-Stairs Garage
Orie2 Job No. 158.033-23
1. Design Criteria & Loads ................................................................................ 1 -5
2. Stairs Model .................................................................................................. 6 -26
3. Stairs Connections Analysis ....................................................................... 27 -55
4. Railing Analysis .......................................................................................... 56 -81
5. Appendix ..................................................................................................... 82 -85
3/17 /23, 10:54 AM ATC Hazards by Location
A This 1s a beta release of lhe new ATC Hazard& by Localiorl website Please contact u& with feedback.
O The ATC Hazards by Location website w,11 not be updalecl lo support ASCE 7-22. EL'll!..!ll!L,yj]Y,
l\TC Hazards by Location
Search Information
Address:
Coordinates:
Elevation:
Timestamp:
Hazard Type:
Reference Document:
Risk Category:
Site Class:
Basic Parameters
Name Value
Ss 1.041
s, 0.377
s.,s 1.249
s.,, • null
Sos 0.833
So1 • null
• See Section 11.4 .8
1205Aviara Pkwy, Carlsbad, CA92011, USA
33.1217135, -117.3029721
85 tt
2023-03-17T17:54:23. 1892
Seismic
ASCE7-16
D-default
Description
MCER ground motion (period=0.2s)
MCER ground motion (period=1.0s)
Site-modified spectral acceleration value
Site-modified spectral acceleration value
Numeric seismic design value at 0.2s SA
Numeric seismic design value at 1,0s SA
•Additional Information
Name Value
SDC • null
Fa 1.2
Fv • null
CR5 0.894
CR1 0.905
PGA 0.458
FPGA 1.2
PGA., 0.549
TL 8
SsRT 1.041
SsUH 1.165
SsD 1.5
S1RT 0.377
S1UH 0.417
S1D 0.6
PGAd 0.531
• See Section 11.4.8
Description
Seismic design category
Site amplification factor at 0.2s
Site amplification factor at 1.0s
Coefficient of risk (0.2s)
Coefficient of risk (1.0s)
MCEG peak ground acceleration
Site amplification factor at PGA
Site modified peak ground acceleration
Long-period transition period (s)
Probabilistic risk-targeted ground motion (0.2s)
Factored uniform-hazard spectral acceleration (2% probability of
exceedance in 50 years)
Factored deterministic acceleration value (0.2s)
Probabilistic risk-targeted ground motion (1.0s)
Factored uniform-hazard spectral acceleration (2% probability of
exceedance in 50 years)
Factored deterministic acceleration value (1.0s)
Factored deterministic acceleration value (PGA)
TefTJ<!Cula 0
85 ft
ca,,J
0 E$COOdido
San Diego -o
Bo11ego
Sp,~ngs
Page 1
Anza-Borrego
Desert
State Park
Cleveland
National Forest i Map data 02023 Google, INEGI
The results indicated here DO NOT 1eflect any state or local amendments to the values or any delmeation lines made during the buildir~9 code adoption process Users should confirm any
output obtained from this tool with the local Authority Havmg Junsd1ction before proceeding with design.
Please note that the ATC Hazards by Location website will not be updated to support ASCE 7-22. f.,nq9ut..,.,h;,,
Disclaimer
https://hazards.atcouncil.org/#/seismic?lat=33.1217135&Ing=-117.3029721 &address=1205 Aviara Pkwy%2C Carlsbad%2C CA 92011 %2C USA 1/2
.0
CMU WALL
TYP.
Orie2 Engineering
Sttucturat Eng/fleers
9750 Miramar Road. Suite 310
San o,ego. CA 92126
Fax: (858) 586-0911
7 TREADS @.11"=6!..S
I
I NL r-
Project No. : 158.033-23
PROJECT: Aviara-lFA-Stairs Garage
Aviara Garage Stairs #1 & #2
I.I.
Page 2
DATE: 3/16/23
BY : ESY
I I
I --=L~-=~~-=~~-=-N
------
.1/2 0.0. TUBE
A.NDRAIL (TYP)
L l/2 O.D. TUBE
CAIN RAIL
OPP.
TYP
---
I
1--I
I
I
I
1---
I
I
1--I
I
I
I
1---
I
I
1-
I
I
I
I UP
ffi u z H e:: j-
V)
I ID
0
rl >< N .-i
;,. ...... 'l'i'l--"'?1
rl"' Ei:'
rl -' ~
~'<I'...., uj
~
C. ::::,
V)
~ "" >< .,. u
__J
I
;'\.
I
MC12X10 .6-STRINGER ~ iH::-=+-_-_-_-___ ___J_ .... _-_-_-_-r-_-+--+-t=11=·
I
I
I
_I _
I
I
UP 1
I
I
I _ I_
I
I
I
I
I
I
I
I
C8Xll. 5
TOS=+6'-6.J3/
~TYJ
C4X1.25 I
I
I
I
I
I
I
1...__ ................. .........,
---1
I
---1
2" LT. WT. CONCRETt. 1 ...-/\
OVER 10 GA.PL 1 11
I
I
EL1.=+6' -3 4"
r I T 0. LAN NG I I
NL .,f-~ 4~,.1'-l ---=T=RE=-t~~~0=o=IM~· _--1---.....tJ i
/,.,<-< ______ 7_TR_EA_D_S_@._11_' '_'=_6_!.._5 ____ __,,,j<-L _____ ...;._4_!..4.:.._ ____ --,1g1i~
2"LT.WT.CONCRETE
OVER 10 GA.PL
u.
u.
"$
rl --_,
rl
~ ....
0 _,
N
,.,.,
U"l _,
m
Orie2 Engineering
Structumf Eogioeers
9750 Miramar Road. Suite 310
san Diego. CA 92126
Fax (858) 586-0911
I HSS1_1/2X'.L.l/2Xl/B
TOP & BOTT. RAI S (TYP.)
HSSL1/2XL 1/2X3/16
POST ~ '-0 0 . C
HSS5/SX5/8Xl/16
PICKETS ~··o.c
2'-2
._1/2 0 . D.. TUBE 1
-tANDRAIL VP.
0 .... .,
N
~N.L.
I ,r
0 .-l .,
"'
L3X3Xl/4
SUPPORT
Project No. : 158.033-23
PROJECT: Aviara-lFA-Stairs Garage
Aviara Garage Stairs #1 & #2
Page 3
DATE: 3/16/23
BY : ESY
II • ...J 1-UJ
~~~-~--
~~r----~-~--
00
'+10
~-,~
::➔ 111,
.. , I.I) .....
I :
I I
I I I I
I I
14 I
MC12X10.6
_MC12Xl0.6
1 L3X3Xl/4 I SUPPORT ---,,,..., ________________ _
I
12 I
I
CMU WALL
("TYP)
-
,....
$
I ._,
~~ ~_., ~~
$
V, _,
~--
M _,
N
0 UJ • let: 'H ;.., I-
Vl
er:
QO
...... ... -::;,.
I ...,, .. ;::;..
'°
V)
0::
00
~ ~
'1'J,
!;:'}
er: ...,.
v ·
'1 00 I .
!
...J w
:.,. ..., -..... z M H 1 0
"' z 1<( • ....J V • + 0 II •
..J 1-UJ
~ H 0 :z :5
0
I-
V -..... 'i.
'1 ....
V, j
I :s .
1 0 II ....J I-w
Orie 1 Engineering
Structural & Bridge Engineers
Project No.· c.•-=58"-'.0"'3-'-3·cc23'------------
9750 Miram.1r Ro$d, Suite 310
San Diego. CA 92126
Phone# (858) 335--7643 PROJECT; Aviara-lFA-Statrs Garage
SEISMIC DEMANDS ON NONSTRUCTURAL COMPONENTS ASCE 7-16 13.3.1
Code: 2022 CBC, ASCE 7-16 CHAPTER 11, 12, 13 SEISMIC DESIGN CRITERIA
Soil Site Class: D Table 20-3-1, Default = D
s.: 104.1
s,: 37.7
F.: 1.200
Fv: 1.923
SM5: 1.249
SM,: 0.725
S05: 0.833
Sa,: 0.483
%9
%9
(USGS using Latitude/Longitude)
Table 11.4-1
Table 11.4-2
F3 S,
Fv•S,
2/3(SMs)
2/3(SM,l
Occupancy: Component: Egress Stair
Ip: 1.5 ASCE 7-16, Section 13.1.3
Component = Rigid -Limited deformability elements and attachments
ap = 1 ASCE 7-16, Table 13.5-1 or 13.6-1
Rp = 2.5
ht, of struct to pt. of attachment, z = 5
ave. roof height to base, h = 6
Seismic Force:
F P = 0 .4apSos
(Rpilp)
Fp = 0.533 x WP
Fp,mln = 0.3Soslp x WP
Fp,mln = 0.375 X WP
F p,max = 1.6Soslp X W p
Fp,max = 1.999 X WP
FP = 0.533
x (1+2(z/h)) x WP ASCE 7-16, Eq 13.3-1
<--Governs
ASCE 7-16, Eq 13.3-3
ASCE 7-16, Eq 13.3-2
(LRFD)
Page 4
DATE: 03117123
BY : ESY
Page 5
~ Orie 2 Engineering
·~j Structural & Bridge Engineers
Project No. : _1.c.58'----.0-'--'3'-'-3--2-3 _____ _ DATE: 03/17/23
9750 Miramar Rd., Suite 310 Phone#: (858) 335-7643 PROJECT : Aviara-lFA-Stairs Garage BY:
San Diego, CA 92126
Gravity Design Loads
CODE: 2022 California Building Code (CBC)
DEAD LOAD
Stringer Dead Load
Precast Treads
Misc.
MC12x10.6 Stringer
Landing Dead Load
10 GA Metal Pan
2" Lightweight Concrete Fill
Framing Members
FLOOR LIVE LOADS:
Seismic Design @ Stringers
Fp Seismic=
MC12x10.6 =
1/2 Width of Stairs =
Fp =
Seismic Design @ Landing
Fp Seismic=
MC12x10.6 =
C8x11.5=
C4x7.25 =
Sub-Total:
Total:
Sub-Total:
38.0 psf
2.0 psf
40.0 psf
5.3 psf
45.3 psf
6.0 psi
19.0 psf
25.0 psi
Varies
100.0 psi
0.533 •w (Strength)
10.6 pit
2.00 ft
48.3 pit
Egress Stairs
0.533 •w (Strength)
10.6 pit
11.5 plf
7.25 plf
Total Length of MC12x10.6 =
Total Length of C8x11.5 =
Total Length of C4x7.25 =
8 ft Weight of MC12x10.6 =
8 ft Weight of C8x11.5 =
4 ft Weight of C4x7.25 =
ESY
Total Weight of Landing Members =
Total Area of Landing =
Length of Seismic Members =
Fp =
16.0 sqft
20.0 ft
16.1 pit
"Seismic Members" are members to which seismic load is applied in the analysis
Fp = ( Total Weight of Landing Members x Cs/ Length of Seismic Members )
+ ( Dead Load (PSF) x Total Area of Landing x Cs/ Length of Seismic Members)
84.8 lb
92 lb
291b
2061b
Envelope Only Solution
IIIRISA ~O_r_ie_2_E_n_gi_ne_e_ri_ng_,_ln_c_. --1
ESY
Section Set
SK-1
Page 6
Section Sets
CMC12x10.6
C8x11 .,5
C4x7.25
Mar 17, 2023 at 04:34 PM
Aviara Stairs GARAGE.r3d
Loads: BLC 1, D
Envelope Only Solution
II IRISA i...:0:.:r.:.:ie-=-2_E.....:ng::....in_e_e_rin_;;g_,_ ln_c._7 .. .••. .• ·'" .,. ~E::.::S:..:.Y ______ -----i
Dead Load
Page 7
SK-2
Mar 17, 2023 at 04:35 PM
Aviara Stairs GARAGE.r3d
Loads: BLC 2, L
Envelope Only Solution
II IRISA L,:O::,:r_::ie:::.2-=E.:..::ng~in_:e_e_rin....::g~, _I n_c._--;
•• •• •• AM• 1-..'.E:..::S::....:Y _______ I
Live Load
Page 8
SK-3
Mar 17, 2023 at 04:35 PM
Aviara Stairs GARAGE.r3d
Loads: BLC 3, Ex
Envelope Only Solution
IIIRISA 1-0_r_ie_2_E_n_gi_ne_e_ri_ng_,_ln_c_. --1
ESY
Seismic Load X
Page 9
SK-4
Mar 17. 2023 at 04:35 PM
Aviara Stairs GARAGE.r3d
Loads: BLC 4, Ez
Envelope Only Solution
II I RISA 1-0_r_ie_2_E_n_gi_ne_e_ri_ng_,_ln_c_. ---1
ESY
Seismic Load Z
Page 10
0.017 k/ft
SK-5
Mar 17, 2023 at 04:35 PM
Aviara Stairs GARAGE.r3d
Member Code Checks Displayed (Enveloped)
Envelope Only Solution
IIIRISA f-O_ri_e2_En_g_in_e_er_in_g_, l_nc_. ----i
ESY
Code Check (Bending)
SK-6
Page 11
Code Check
(Env)
No Cale
> 1.0
.90-1 .0
.75-.90
.50-.75
■ 0.-.50
Mar 17, 2023 at 04:35 PM
Aviara Stairs GARAGE.r3d
Company
Designer
: Orie2 Engineering, Inc.
: ESY IIIRISA
A NCMC rsCHfK COMPANY
Job Number
Model Name:
Model Settinas
Number of Renorted Sections
Number of Internal Sections
Member Area Load Mesh Size 0n2\
Consider Shear Deformation
Consider Torsional Waroina
Annroximate Mesh Size /in)
Transfer Forces Between lntersectina Wood Walls
Increase Wood Wall Nailina Caoacitv for Wind Loads
Include P-Delta for Walls
Ootimize Masonrv and Wood Walls
Maximum Number of Iterations
Sinale
Multiole /Ootimum\
Maximum
Global Axis corresnondina to vertical direction
Convert Existinn Data
Default Global Plane for z-axis
Plate Local Axis Orientation
Hot Rolled Steel
Stiffness Adiustment
Notional Annex
Connections
Cold Formed Steel
Stiffness Adiustment
Wood
Temnerature
Concrete
Masonrv
Aluminum
Structure Tvoe
Stiffness Adiustment
Stainless
Stiffness Adiustment
Comoression Stress Block
Analvze usinn Cracked Sections
Leave room for horizontal rebar solices (2*d bar snacina)
List forces which were ianored for desian in the Detail Reoort
Column Min Steel
Column Max Steel
Rebar Material Snee
Warn if beam-column framina arranaement is not understood
Number of Shear Reaions
Reaion 2 & 3 Snacina Increase Increment /in\
Code
Risk Catenorv
Drift Cat
5
100
144
Yes
Yes
24
Yes
Yes
Yes
Yes
3
No
Yes
No
y
Yes
xz
Global
AISC 15th £360-16): ASD
Yes /Iterative\
None
AISC 14th 1360-10): ASD
AISI S100-16: ASD
Yes /Iterative\
AWC NDS-18 / SDPWS-15 ASD
< 100F
ACI 318-19
TMS 402-16: ASD
AA ADM1-15: ASD
Buildina
Yes /Iterative)
AISC 14th 1360-10): ASD
Yes /Iterative)
Rectanaular Stress Block
Yes
Yes
Yes
1
8
ASTM A615
No
4
4
ASCE 7-16
I or II
Other
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d ]
Page 12
3/17/2023
4:58:20 PM
Checked By:
Page 1
IIIRISA
Company
Designer
: Orie2 Engineering, Inc.
: ESY
Job Number
Model Name:
Model Settinas (Continued)
Base Elevation /ft\
Include the weiaht of the structure in base shear calcs
S (a\
SD, la\
SD. (a\
T, /sec\
T Z <sec\
TX (sec\
CZ
ex
CExo. Z
CExo. X
RZ
RX
OnZ
OnX
CaZ
C,X
oz
ox
Yes
1
1
1
5
0.02
0.02
0.75
0.75
3
3
1
1
4
4
1
1
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d]
Page 13
3/17/2023
4:58:20 PM
Checked By :
Page 2
IIIRISA
Node Coordinates
Label
1 N17
2 N18
3 N19
4 N20
5 N21
6 N22
7 N23
8 N24
9 N25
10 N26
11 N27
12 N28
13 N29
14 N30
15 N31
16 N32
17 N33
18 N34
19 N35
20 N36
21 N37
22 N38
23 N39
24 N40
25 N41
26 N42
27 N43
28 N44
29 N45
30 N46
31 N47
32 N48
33 N49
34 N50
35 N51
36 N52
37 N53
38 N54
39 N55
40 N56
41 N57
42 N58
43 N59
44 N60
45 N61
46 N62
47 N63
48 N64
49 N65
50 N66
51 N67
52 N68
53 N69
54 N70
55 N71
RISA-3D Version 21
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name:
X fftl Y fftl Z fftl
28.582907 -11.250288 -0.000333
21 .1 6624 -4.500287 -11 .083666
21.16624 -4.500287 -7.083666
28.582907 -6.750287 -9.083666
24.582907 -11.250288 -0.000333
17.16624 -0.000287 -0.000333
17.16624 -4.500287 -11.083666
21.16624 -0.000287 -0.000333
28.582907 -6.750287 -7.083666
28.582907 -6.750287 -11.083666
17.16624 -4.500287 -7.083666
24.582907 -6.750287 -7.083666
24.582907 -6.750287 -11.083666
24.582907 -6.750287 -9.083666
19.16624 -4.500287 -11 .083666
19.16624 -4.500287 -7.083666
28.582907 -6.750287 -8.083666
17.16624 -4.500287 -8.083666
17.16624 -4.500287 -10.583666
28.582907 -6.750287 -10.583666
28.082907 -6.750287 -11.083666
25.582907 -6.750287 -11 .083666
17.66624 -4.500287 -11.083666
20.16624 -4.500287 -11.083666
17.16624 -4.500287 -7.583666
17.66624 -4.500287 -7.583666
17.66624 -4.500287 -7.083666
18.16624 -4.500287 -7.583666
18.16624 -4.500287 -7.083666
18.66624 -4.500287 -7.583666
18.66624 -4.500287 -7.083666
19.16624 -4.500287 -7.583666
19.66624 -4.500287 -7.583666
19.66624 -4.500287 -7.083666
20.16624 -4.500287 -7.583666
20.16624 -4.500287 -7.083666
20.66624 -4.500287 -7.583666
20.66624 -4.500287 -7.083666
21.16624 -4.500287 -7.583666
17.66624 -4.500287 -8.083666
18.16624 -4.500287 -8.083666
18.66624 -4.500287 -8.083666
19.16624 -4.500287 -8.083666
19.66624 -4.500287 -8.083666
20.16624 -4.500287 -8.083666
20.66624 -4.500287 -8.083666
21 .16624 -4.500287 -8.083666
17.16624 -4.500287 -8.583666
17.66.624 -4.500287 -8.583666
18.16624 -4.500287 -8.583666
18.66624 -4.500287 -8.583666
19.16624 -4.500287 -8.583666
19.66624 -4.500287 -8.583666
20.16624 -4.500287 -8.583666
20.66624 -4.500287 -8.583666
[ Aviara Stairs GARAGE.r3d]
Page 14
3/17/2023
4:58:20 PM
Checked By :
Detach From Diaohraqm
Page 3
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number :
ANf:METt"iCHf:I\ COMPANY Model Name:
Node Coordinates (Continued)
Label Xfftl y fftl Z fftl
56 N72 21.16624 -4.500287 -8.583666
57 N73 17.16624 -4.500287 -9.083666
58 N74 17.66624 -4.500287 -9.083666
59 N75 18.16624 -4.500287 -9.083666
60 N76 18.66624 -4.500287 -9.083666
61 N77 19.16624 -4.500287 -9.083666
62 N78 19.66624 -4.500287 -9.083666
63 N79 20.16624 -4.500287 -9.083666
64 N80 20.66624 -4.500287 -9.083666
65 N81 21.16624 -4.500287 -9.083666
66 N82 17.16624 -4.500287 -9.583666
67 N83 17.66624 -4.500287 -9.583666
68 N84 18.16624 -4.500287 -9.583666
69 N85 18.66624 -4.500287 -9.583666
70 N86 19.16624 -4.500287 -9.583666
71 N87 19.66624 -4.500287 -9.583666
72 N88 20.16624 -4.500287 -9.583666
73 N89 20.66624 -4.500287 -9.583666
74 N90 21 .16624 -4.500287 -9.583666
75 N91 17.16624 -4.500287 -10.083666
76 N92 17.66624 -4.500287 -10.083666
77 N93 18.16624 -4.500287 -10.083666
78 N94 18.66624 -4.500287 -10.083666
79 N95 19.16624 -4.500287 -10.083666
80 N96 19.66624 -4.500287 -10.083666
81 N97 20.16624 -4.500287 -10.083666
82 N98 20.66624 -4.500287 -10.083666
83 N99 21 .16624 -4.500287 -10.083666
84 N100 17.66624 -4.500287 -10.583666
85 N101 18.16624 -4.500287 -10.583666
86 N102 18.66624 -4.500287 -10.583666
87 N103 19.16624 -4.500287 -10.583666
88 N104 19.66624 -4.500287 -10.583666
89 N105 20.16624 -4.500287 -10.583666
90 N106 20.66624 -4.500287 -10.583666
91 N1 07 21.16624 -4.500287 -10.583666
92 N108 18.16624 -4.500287 -11.083666
93 N109 18.66624 -4.500287 -11.083666
94 N110 19.66624 -4.500287 -11.083666
95 N111 20.66624 -4.500287 -1 1.083666
96 N112 24.582907 -6.750287 -7.583666
97 N113 25.082907 -6.750287 -7.583666
98 N114 25.082907 -6.750287 -7.083666
99 N115 25.582907 -6.750287 -7.583666
100 N116 25.582907 -6.750287 -7.083666
101 N117 26.082907 -6.750287 -7.583666
102 N118 26.082907 -6.750287 -7.083666
103 N119 26.582907 -6.750287 -7.583666
104 N120 26.582907 -6.750287 -7 .083666
105 N121 27.082907 -6.750287 -7.583666
106 N122 27.082907 -6.750287 -7.083666
107 N123 27.582907 -6.750287 -7.583666
108 N124 27.582907 -6.750287 -7.083666
109 N125 28.082907 -6.750287 -7.583666
110 N126 28.082907 -6.750287 -7.083666
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d]
Page 15
3/17/2023
4:58:20 PM
Checked By:
Detach From Diaohraqm
Page 4
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number :
Model Name:
Node Coordinates (Continued)
Label X [ft] Y rftl z [ft]
111 N127 28.582907 -6.750287 -7.583666
112 N128 24.582907 -6.750287 -8.083666
113 N129 25.082907 -6.750287 -8.083666
114 N130 25.582907 -6.750287 -8.083666
115 N131 26.082907 -6.750287 -8.083666
116 N132 26.582907 -6.750287 -8.083666
117 N133 27.082907 -6.750287 -8.083666
118 N134 27.582907 -6.750287 -8.083666
119 N135 28.082907 -6.750287 -8.083666
120 N136 24.582907 -6.750287 -8.583666
121 N137 25.082907 -6.750287 -8.583666
122 N1 38 25.582907 -6.750287 -8.583666
123 N139 26.082907 -6.750287 -8.583666
124 N140 26.582907 -6.750287 -8.583666
125 N141 27.082907 -6.750287 -8.583666
126 N142 27.582907 -6.750287 -8.583666
127 N143 28.082907 -6.750287 -8.583666
128 N144 28.582907 -6.750287 -8.583666
129 N145 25.082907 -6.750287 -9.083666
130 N146 25.582907 -6.750287 -9.083666
131 N147 26.082907 -6.750287 -9.083666
132 N148 26.582907 -6.750287 -9.083666
133 N149 27.082907 -6.750287 -9.083666
134 N150 27.582907 -6.750287 -9.083666
135 N151 28.082907 -6.750287 -9.083666
136 N152 24.582907 -6.750287 -9.583666
137 N153 25.082907 -6.750287 -9.583666
138 N154 25.582907 -6.750287 -9.583666
139 N1 55 26.082907 -6.750287 -9.583666
140 N156 26.582907 -6.750287 -9.583666
141 N157 27.082907 -6.750287 -9.583666
142 N158 27.582907 -6.750287 -9.583666
143 N159 28.082907 -6.750287 -9.583666
144 N160 28.582907 -6.750287 -9.583666
145 N161 24.582907 -6.750287 -10.083666
146 N162 25.082907 -6.750287 -10.083666
147 N163 25.582907 -6.750287 -10.083666
148 N1 64 26.082907 -6.750287 -10.083666
149 N165 26.582907 -6.750287 -10.083666
150 N166 27.082907 -6.750287 -10.083666
151 N167 27.582907 -6.750287 -10.083666
152 N168 28.082907 -6.750287 -10.083666
153 N169 28.582907 -6.750287 -10.083666
154 N170 24.582907 -6.750287 -10.583666
155 N171 25.082907 -6.750287 -10.583666
156 N172 25.582907 -6.750287 -10.583666
157 N173 26.082907 -6.750287 -10.583666
158 N174 26.582907 -6.750287 -10.583666
159 N175 27.082907 -6.750287 -10.583666
160 N176 27.582907 -6.750287 -10.583666
161 N177 28.082907 -6.750287 -10.583666
162 N178 25.082907 -6.750287 -11 .083666
163 N179 26.082907 -6.750287 -11.083666
164 N180 26.582907 -6.750287 -11 .083666
165 N181 27.082907 -6.750287 -11.083666
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d)
Page 16
3/17/2023
4:58:20 PM
Checked By:
Detach From Diaohraqm
Page 5
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name:
Node Coordinates (Continued)
Label X ft y ft
166 N182 27.582907 -6.750287
Hot Rolled Steel Properties
z ft
-11.083666
Page 17
311712023
4:58:20 PM
Checked By:
Detach From Dia hra m
Label E fksil G fksil Nu Therm Coeff 11 e5°F-'1 Density [k/ft3l Yield [ksil Rv Fu fksil Rt
1 A992 29000 11154 0.3 0.65 0.49 50 1.1 65 1.1
2 A36 Gr.36 29000 11154 0.3 0.65 0.49 36 1.5 58 1.2
3 A572 Gr.50 29000 11154 0.3 0.65 0.49 50 1.1 65 1.1
4 A500 Gr.B RND 29000 11154 0.3 0.65 0.527 42 1.4 58 1.3
5 A500 Gr.B RECT 29000 11154 0.3 0.65 0.527 46 1.4 58 1.3
6 A500 Gr.C RND 29000 11154 0.3 0.65 0.527 46 1.4 62 1.3
7 A500 Gr.C RECT 29000 11154 0.3 0.65 0.527 50 1.4 62 1.3
8 A53 Gr.B 29000 11154 0.3 0.65 0.49 35 1.6 60 1.2
9 A1085 29000 11154 0.3 0.65 0.49 50 1.4 65 1.3
10 A913 Gr.65 29000 11154 0.3 0.65 0.49 65 1.1 80 1.1
Hot Rolled Steel Design Parameters
Label Shaoe Lenath lftl Lb v-v [ft] Lb z-z [ftl Lcom o too lftl Lcomo bot fftl Channel Conn a fftl Function
1 M17 MC12x10.6 4.091 1 1 1 1 NIA NIA Lateral
2 M18 MC12x10.6 8.392 1 1 1 1 NIA NIA Lateral
3 M19 MC12x10.6 4 1 1 NIA NIA Lateral
4 M20 C8x11. 5 4 1 1 NIA NIA Lateral
5 M21 MC12x10.6 4 1 1 NIA NIA Lateral
6 M22 C8x1 1. 5 4 1 1 NIA NIA Lateral
7 M23 MC12x10.6 4 1 1 NIA NIA Lateral
8 M24 C8x11. 5 4 1 1 NIA NIA Lateral
9 M25 MC12x10.6 8.392 1 1 1 1 NIA NIA Lateral
10 M26 MC12x10.6 4.091 1 1 1 1 NIA NIA Lateral
11 M27 MC12x10.6 8.392 1 1 1 1 NIA NIA Lateral
12 M28 MC12x10.6 8.392 1 1 1 1 NIA NIA Lateral
13 M29 MC12x10.6 4 1 1 NIA NIA Lateral
14 M30 C8x11. 5 4 1 1 NIA NIA Lateral
15 M31 C4x7.25 4 1 1 NIA NIA Lateral
16 M32 C4x7.25 4 1 1 NIA NIA Lateral
Hot Rolled Steel Section Sets
Label Shaoe Tvoe Desiqn List Material Desian Ru le Area lin21 lvv fin•l lzz [in•] J [in•]
1 MC12x10.6 MC12X10.6 Beam Channel A36 Gr.36 Tvoical 3.1 0.378 55.3 0.06
2 C8x11. 5 C8X11.5 Beam Channel A36 Gr.36 Tunical 3.37 1.31 32.5 0.13
3 C4x7.25 C4X7.25 Beam Channel A36 Gr.36 Tvoical 2.13 0.425 4.58 0.082
Plate Primary Data
Label A Node B Node C Node D Node Material Thickness linl
1 P3 N27 N41 N42 N43 nen Steel 0.135
2 P4 N43 N42 N44 N45 aen Steel 0.135
3 P5 N45 N44 N46 N47 nen Steel 0.135
4 P6 N47 N46 N48 N32 aen Steel 0.135
5 P7 N32 N48 N49 N50 aen Steel 0.135
6 P8 N50 N49 N51 N52 aen Steel 0.135
7 pg N52 N51 N53 N54 aen Steel 0.135
8 P10 N54 N53 N55 N19 nen Steel 0.135
RISA-3O Version 21 [ Aviara Stairs GARAGE.r3d ] Page 6
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name:
Plate Primary Data (Continued)
Label A Node B Node C Node D Node
9 P11 N41 N34 N56 N42
10 P12 N42 N56 N57 N44
11 P13 N44 N57 N58 N46
12 P14 N46 N58 N59 N48
13 P15 N48 N59 N60 N49
14 P16 N49 N60 N61 N51
15 P17 N51 N61 N62 N53
16 P18 N53 N62 N63 N55
17 P19 N34 N64 N65 N56
18 P20 N56 N65 N66 N57
19 P21 N57 N66 N67 N58
20 P22 N58 N67 N68 N59
21 P23 N59 N68 N69 N60
22 P24 N60 N69 N?0 N61
23 P25 N61 N?0 N71 N62
24 P26 N62 N71 N72 N63
25 P27 N64 N73 N74 N65
26 P28 N65 N74 N75 N66
27 P29 N66 N75 N76 N67
28 P30 N67 N76 N77 N68
29 P31 N68 N?? N78 N69
30 P32 N69 N78 N79 N?0
31 P33 N?0 N79 NB0 N71
32 P34 N71 N80 N81 N72
33 P35 N73 N82 N83 N74
34 P36 N74 N83 N84 N75
35 P37 N75 N84 N85 N76
36 P38 N76 N85 N86 N??
37 P39 N?? N86 N87 N78
38 P40 N78 NB? N88 N79
39 P41 N79 N88 N89 N80
40 P42 NB0 N89 N90 N81
41 P43 N82 N91 N92 N83
42 P44 N83 N92 N93 N84
43 P45 N84 N93 N94 N85
44 P46 N85 N94 N95 N86
45 P47 N86 N95 N96 NB?
46 P48 N87 N96 N97 N88
47 P49 N88 N97 N98 N89
48 P50 N89 N98 N99 N90
49 P51 N91 N35 N100 N92
50 P52 N92 N100 N101 N93
51 P53 N93 N101 N102 N94
52 P54 N94 N102 N103 N95
53 P55 N95 N103 N104 N96
54 P56 N96 N104 N105 N97
55 P57 N97 N105 N106 N98
56 P58 N98 N106 N107 N99
57 P59 N35 N23 N39 N100
58 P60 N100 N39 N108 N101
59 P61 N101 N108 N109 N102
60 P62 N102 N109 N31 N103
61 P63 N103 N31 N110 N104
62 P64 N104 N110 N40 N105
63 P65 N1 05 N40 N 111 N106
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d]
Material
□en Steel
aen Steel
aen Steel
nen Steel
□en Steel
□en Steel
aen Steel
aen Steel
aen Steel
□en Steel
nen Steel
aen Steel
aen Steel
aen Steel
□en Steel
aen Steel
aen Steel
nen Steel
□en Steel
nen Steel
aen Steel
□en Steel
aen Steel
□en Steel
aen Steel
aen Steel
aen Steel
□en Steel
aen Steel
□en Steel
aen Steel
□en Steel
nen Steel
aen Steel
□en Steel
aen Steel
aen Steel
nen Steel
□en Steel
aen Steel
□en Steel
aen Steel
□en Steel
□en Steel
nen Steel
□en Steel
aen Steel
nen Steel
□en Steel
aen Steel
□en Steel
nen Steel
□en Steel
aen Steel
aen Steel
Page 18
3/17/2023
4:58:20 PM
Checked By:
Thickness finl
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.1 35
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.1 35
0.135
0.135
Page 7
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A NtMt:: T~',GHfK COMPANY Model Name:
Plate Primary Data (Continued)
Label A Node B Node C Node D Node
64 P66 N106 N111 N18 N107
65 P67 N28 N112 N113 N114
66 P68 N114 N113 N1 15 N116
67 P69 N116 N115 N117 N118
68 P70 N118 N117 N119 N120
69 P71 N120 N119 N121 N122
70 P72 N122 N121 N123 N124
71 P73 N124 N123 N125 N126
72 P74 N126 N125 N127 N25
73 P75 N112 N128 N129 N113
74 P76 N113 N129 N130 N115
75 P77 N115 N130 N131 N117
76 P78 N117 N131 N132 N119
77 P79 N119 N132 N133 N121
78 P80 N121 N133 N134 N123
79 P81 N123 N134 N135 N125
80 P82 N125 N135 N33 N127
81 P83 N128 N136 N137 N129
82 P84 N129 N137 N138 N130
83 P85 N130 N1 38 N139 N131
84 P86 N131 N139 N140 N132
85 P87 N132 N140 N141 N133
86 P88 N133 N141 N142 N134
87 P89 N134 N142 N143 N135
88 P90 N135 N143 N144 N33
89 P91 N136 N30 N145 N137
90 P92 N137 N145 N146 N138
91 P93 N138 N146 N147 N139
92 P94 N139 N147 N148 N140
93 P95 N140 N148 N149 N141
94 P96 N141 N149 N150 N142
95 P97 N142 N150 N151 N143
96 P98 N143 N151 N20 N144
97 P99 N30 N152 N153 N145
98 P100 N145 N153 N154 N146
99 P101 N146 N154 N155 N147
100 P102 N147 N155 N1 56 N148
101 P103 N148 N156 N157 N149
102 P104 N149 N157 N1 58 N150
103 P105 N150 N158 N159 N151
104 P106 N151 N159 N1 60 N20
105 P107 N152 N161 N162 N1 53
106 P108 N153 N162 N1 63 N154
107 P109 N154 N163 N164 N155
108 P110 N155 N164 N1 65 N156
109 P111 N156 N165 N166 N157
110 P112 N157 N166 N167 N158
111 P113 N158 N167 N168 N159
112 P114 N159 N168 N169 N160
113 P115 N161 N170 N171 N162
114 P116 N162 N171 N172 N163
115 P117 N163 N172 N173 N164
116 P118 N164 N173 N174 N165
117 P119 N165 N174 N175 N166
118 P120 N166 N175 N176 N167
RISA-30 Version 21 [ Aviara Stairs GARAGE.r3d]
Material
aen Steel
nen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
oen Steel
aen Steel
nen Steel
aen Steel
nen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
nen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
aen Steel
nen Steel
aen Steel
aen Steel
aen Steel
aen Steel
nen Steel
nen Steel
nen Steel
aen Steel
aen Steel
nen Steel
aen Steel
nen Steel
aen Steel
nen Steel
aen Steel
aen Steel
aen Steel
aen Steel
nen Steel
Page 19
3/17/2023
4:58:20 PM
Checked By :
Thickness finl
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
Page 8
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name:
Plate Primary Data (Continued)
Label A Node B Node C Node D Node Material
119 P121 N167 N176 N177 N168 aen Steel
120 P122 N168 N177 N36 N169 aen Steel
121 P123 N170 N29 N178 N171 aen Steel
122 P124 N1 71 N178 N38 N1 72 aen Steel
123 P1 25 N172 N38 N179 N173 aen Steel
124 P126 N173 N1 79 N1 80 N174 aen Steel
125 P127 N1 74 N180 N1 81 N175 aen Steel
126 P128 N1 75 N1 81 N1 82 N176 aen Steel
127 P129 N176 N182 N37 N177 aen Steel
128 P130 N177 N37 N26 N36 aen Steel
Design Size and Code Check Parameters
Label Max Axial/Bending Chk
Typical
Nodal Loads and Enforced Displacements
No Data to Print...
Member Point Loads
No Data to Print...
Member Distributed Loads (BLC 3 : Ex)
Page 20
3/17/2023
4:58:20 PM
Checked By :
Thickness finl
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
0.135
Max Shear Chk
em er a e irect1on tart aanitu e t s, -n aanitu e l I s I -tart ocat1on ' 0 M b L b I D" S M • d [k/ft F k f k ft/fll E d M • d lk/fl F k f k ft/fll S L • [(ft % )l E nd Location [(ft %)1 ' 0
1 M27 X 0.049 0.049 0 %100
2 M25 X 0.049 0.049 0 %100
3 M26 X 0.049 0.049 0 %100
4 M17 X 0.049 0.049 0 %100
5 M28 X 0.049 0.049 0 %100
6 M1 8 X 0.049 0.049 0 %100
7 M29 X 0.017 0.017 0 %100
8 M23 X 0.017 0.017 0 %100
9 M32 X 0.017 0.017 0 %100
10 M24 X 0.017 0.017 0 %100
11 M20 X 0.017 0.017 0 %100
12 M30 X 0.017 0.017 0 %100
13 M21 X 0.017 0.017 0 %100
14 M31 X 0.017 0.017 0 %100
15 M22 X 0.017 0.017 0 %100
16 M19 X 0.017 0.017 0 %100
Member Distributed Loads (BLC 4 : Ez)
Member Label Direction Start Maanitude fk/ft, F. ksf, k-ft/ft] End Maanitude lk/ft, F, ksf, k-ft/ft] Start Location !(ft, % )l End Location [(ft, % )l
1 M27 z 0.049 0.049 0 %100
2 M25 z 0.049 0.049 0 %100
3 M26 z 0.049 0.049 0 %100
4 M17 z 0.049 0.049 0 %100
5 M28 z 0.049 0.049 0 %100
6 M18 z 0.049 0.049 0 %100
7 M29 z 0.017 0.017 0 %100
8 M23 z 0.017 0.017 0 %100
9 M32 z 0.017 0.017 0 %100
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d ) Page 9
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name:
Member Distributed Loads (BLC 4: Ez/ (Continued)
Page 21
3/17/2023
4:58:20 PM
Checked By:
Member Label Direction Start Maonitude fk/ft, F, ksf, k-ft/ftl End Maanitude fk/ft, F ksf, k-ft/ftl Start Location rm. % \l End Location rm. % )1
10 M24 z 0.017 0.017 0 %100
11 M20 z 0.017 0.017 0 %100
12 M30 z 0.017 0.017 0 %100
13 M21 z 0.017 0.017 0 %100
14 M31 z 0.017 0.017 0 %100
15 M22 z 0.017 0.017 0 %100
16 M19 z 0.017 0.017 0 %100
Member Distributed Loads (BLC 5 : BLC 1 Transient Area Loads)
Member Label Direction Start Maqnitude fk/ft, F, ksf, k-ft/ftl End Maanitude fk/ft, F, ksf, k-ft/ftl Start Location I/ft, % )l End Location [(ft, %)1
1 M25 y -0.08 -0.08 7.772e-16 8.392
2 M27 y -0.08 -0.08 1.443e-15 8.392
3 M18 y -0.08 -0.08 3.331e-16 8.392
4 M28 y -0.08 -0.08 6.661e-16 8.392
5 M17 y -0.08 -0.08 1.11e-15 4.091
6 M26 y -0.08 -0.08 0 4.091
7 M20 y -0.025 -0.025 0 4
8 M23 y -0.025 -0.025 1 4
9 M24 y -0.025 -0.025 1 4
10 M29 y -0.025 -0.025 1 3
11 M32 y -0.05 -0.05 1 3
12 M19 y -0.025 -0.025 1.832e-15 4
13 M21 y -0.025 -0.025 1 4
14 M22 y -0.025 -0.025 1 4
15 M30 y -0.025 -0.025 1 3
16 M31 y -0.05 -0.05 1 3
Member Distributed Loads (BLC 6 : BLC 2 Transient Area Loads)
Member Label Direction Start Magnitude fk/ft, F, ksf, k-ft/ftl End Maanitude [k/ft, F, ksf, k-ft/ftl Start Location rm. % )1 End Location I/ft, % )l
1 M18 y -0.2 -0.2 3.331e-16 8.392
2 M28 y -0.2 -0.2 6.661e-16 8.392
3 M20 y -0.1 -0.1 0 4
4 M23 y -0.1 -0.1 1 4
5 M24 y -0.1 -0.1 1 4
6 M29 y -0.1 -0.1 1 3
7 M32 y -0.2 -0.2 1 3
8 M19 y -0.1 -0.1 1.832e-15 4
9 M21 y -0.1 -0.1 1 4
10 M22 y -0.1 -0.1 1 4
11 M30 y -0.1 -0.1 1 3
12 M31 y -0.2 -0.2 1 3
13 M25 y -0.2 -0.2 5.551e-16 8.392
14 M27 y -0.2 -0.2 1.221e-15 8.392
15 M17 y -0.2 -0.2 1.11e-15 4.091
16 M26 y -0.2 -0.2 0 4.091
Member Area Loads (BLC 1 : DJ
Node A Node B Node C Node D Direction Load Direction Maqnitude fksf]
1 N22 N24 N1 9 N27 y A-8 -0.04
2 N28 N25 N17 N21 y A-8 -0.04
3 N19 N18 N29 N28 y A-8 -0.04
4 N27 N23 N18 N19 y Two Wav -0.025
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d ] Page 10
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A Nf-M~1'SCHEK GOMf>,.\NY Model Name:
Member Area Loads (BLC 1 : D) (Continued)
Node A Node B Node C Node D Direction
5 N28 N29 N26 N25 y
Member Area Loads (BLC 2 ; L/
Node A Node B Node C Node D Direction
1 N27 N23 N18 N19 y
2 N28 N29 N26 N25 y
3 N27 N19 N24 N22 y
4 N19 N1 8 N29 N28 y
5 N28 N25 N17 N21 y
Basic Load Cases
BLC Descriotion Cateaorv Y Gravity
1 D DL -1
2 L LL
3 Ex ELX
4 Ez ELZ
5 BLC 1 Transient Area Loads None
6 BLC 2 Transient Area Loads None
Load Combinations
Description Solve P-Delta BLC Factor
1 D Yes y DL 1
2 L Yes y LL 1
3 D+L Yes y DL 1
4 D + 0.7Ex Yes y DL 1
5 D + 0.7Ez Yes y DL 1
6 D -0.7Ex Yes y DL 1
7 D -0.7Ez Yes y DL 1
8 D + 0.75L + 0.525Ex Yes y DL 1
9 D + 0.75L + 0.525Ez Yes y DL 1
10 D + 0.75L -0.525Ex Yes y DL 1
11 D + 0.75L -0.525Ez Yes y DL 1
12 0.60 + 0.7Ex Yes y DL 0.6
13 0.60 + 0.7Ez Yes y DL 0.6
14 0.60 -0.7Ex Yes y DL 0.6
15 0.60 -0.7Ez Yes y DL 0.6
16 1.40 y DL 1.4
17 1.20 + 1.6L y DL 1.2
18 1.20 + 0.5L + Ex y DL 1.2
19 1.2D + 0.5L + Ez y DL 1.2
20 1.20 + 0.5L-Ex y DL 1.2
21 1.20 + 0.5L -Ez y DL 1.2
22 0.90 + Ex y DL 0.9
23 0.90 + Ez y DL 0.9
24 0.90 -Ex y DL 0.9
25 0.90 -Ez y DL 0.9
26 1.20 + 0.5L + OmenaEx y DL 1.2
27 1.20 + 0.5L + OmeaaEz y DL 1.2
28 1.20 + 0.5L -OmeaaEx y DL 1.2
29 1.20 + 0.5L -OmenaEz y DL 1.2
30 0.90 + OmeaaEx y DL 0.9
31 0.90 + OmenaEz y DL 0.9
RISA-30 Version 21 [ Aviara Stairs GARAGE.r3d )
Load Direction
Two Wa
Load Direction
TwoWav
TwoWav
A-8
A-8
A-B
Distributed
16
16
16
16
BLC Factor
LL 1
ELX 0.7
ELZ 0.7
ELX -0.7
ELZ -0.7
ELX 0.525
ELZ 0.525
ELX -0.525
ELZ -0.525
ELX 0.7
ELZ 0.7
ELX -0.7
ELZ -0.7
LL 1.6
ELX 1
ELZ 1
ELX -1
ELZ -1
ELX 1
ELZ 1
ELX -1
ELZ -1
Om*ELX 1
Om*ELZ 1
Om*ELX -1
Om*ELZ -1
Om*ELX 1
Om*ELZ 1
Page 22
3/17/2023
4:58:20 PM
Checked By :
Ma nitude ks
-0.025
Maqnitude [ksf]
-0.1
-0.1
-0.1
-0.1
-0.1
Area/Member)
5
5
BLC Factor
LL 0.75
LL 0.75
LL 0.75
LL 0.75
LL 0.5
LL 0.5
LL 0.5
LL 0.5
LL 0.5
LL 0.5
LL 0.5
LL 0.5
Page 11
Company
Designer
: Orie2 Engineering, Inc.
: ESY IIIRISA Job Number
Model Name:
Load Combinations (Continued)
Solve P-Delta
32 y
33 y
Load Combination Design
BLC
DL
DL
Factor BLC
0.9 Om*ELX
0.9 Om*ELZ
Factor BLC
-1
-1
Page 23
3/17/2023
4:58:20 PM
Checked By :
Factor
Description CD Service Hot Railed Cold Formed Wood Concrete Masonrv Aluminum Stainless Connection
1 D Yes Yes Yes Yes Yes Yes Yes Yes Yes
2 L Yes Yes Yes Yes Yes Yes Yes Yes Yes
3 D+L Yes Yes Yes Yes Yes Yes Yes Yes Yes
4 D + 0.7Ex 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
5 D + 0.7Ez 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
6 D -0.7Ex 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
7 D -0.7Ez 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
8 D + 0.75L + 0.525Ex 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
9 D + 0.75L + 0.525Ez 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
10 D + 0.75L -0.525Ex 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
11 D + 0.75L -0.525Ez 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
12 0.60 + 0.7Ex 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
13 0.60 + 0.7Ez 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
14 0.60 -0.7Ex 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
15 0.60 -0.7Ez 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes
16 1.40 Yes Yes Yes Yes Yes Yes Yes
17 1.20 + 1.6L Yes Yes Yes Yes Yes Yes Yes
18 1.20 + 0.5L + Ex Yes Yes Yes Yes Yes Yes Yes
19 1.20 + 0.5L + Ez Yes Yes Yes Yes Yes Yes Yes
20 1.20 + 0.5L-Ex Yes Yes Yes Yes Yes Yes Yes
21 1.20 + 0.5L-Ez Yes Yes Yes Yes Yes Yes Yes
22 0.90 + Ex Yes Yes Yes Yes Yes Yes Yes
23 0.90 + Ez Yes Yes Yes Yes Yes Yes Yes
24 0.90 -Ex Yes Yes Yes Yes Yes Yes Yes
25 0.9D-Ez Yes Yes Yes Yes Yes Yes Yes
26 1.20 + 0.5L + OmeaaEx Yes Yes Yes Yes Yes Yes Yes
27 1.20 + 0.5L + OmeoaEz Yes Yes Yes Yes Yes Yes Yes
28 1.20 + 0.5L -OmenaEx Yes Yes Yes Yes Yes Yes Yes
29 1.2D + 0.5L -OmeaaEz Yes Yes Yes Yes Yes Yes Yes
30 0.9D + OmeaaEx Yes Yes Yes Yes Yes Yes Yes
31 0.90 + OmeaaEz Yes Yes Yes Yes Yes Yes Yes
32 0.90 -OmeaaEx Yes Yes Yes Yes Yes Yes Yes
33 0.90 -OmeaaEz Yes Yes Yes Yes Yes Yes Yes
Envelope Node Reactions
Node Label X fkl LC Y fkl LC Z £kl LC MX fk-ftl LC MY fk-ftl LC MZ [k-ft] LC
1 N34 max 1.806 10 1.958 3 0.017 15 0 15 0 15 0 15
2 min -0.094 12 0.345 12 -1.073 3 0 1 0 1 0 1
3 N35 max 0.089 10 -0.109 15 0.017 14 0 15 0 15 0 15
4 min -0.07 12 -0.857 3 -0.264 8 0 1 0 1 0 1
5 N33 max 1.794 10 2.041 3 1.035 3 0 15 0 15 0 15
6 min -0.098 12 0.357 12 -0.029 13 0 1 0 1 0 1
7 N36 max 0.091 6 -0.05 13 0.26 8 0 15 0 15 0 15
8 min -0.073 12 -0.5 3 -0.026 14 0 1 0 1 0 1
9 N17 max 0.11 14 1.821 3 -0.119 15 0 15 0 15 0 15
10 min -0.11 1 4 0.326 12 -1.164 3 0 1 0 1 0 1
11 N21 max 0.144 14 3.635 3 -0.536 15 0 15 0 15 0 15
12 min -0.144 4 0.647 14 -3.822 3 0 1 0 1 0 1
RISA-30 Version 21 [ Aviara Stairs GARAGE.r3d) Page 12
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name:
Envelope Node Reactions (Continued/
Node Label X fkl LC Y [kl LC Z fkl LC MX fk-ftl LC
13 N22 max 0.11 14 1.88 3 1.244 3 0 15
14 min -0.111 4 0.336 12 0.133 13 0 1
15 N24 max 0.144 6 3.645 3 3.833 3 0 15
16 min -0.144 12 0.649 14 0.537 13 0 1
17 N39 max -0.048 14 0.279 3 -0.03 15 0 15
18 min -0.576 3 0.034 15 -0.49 3 0 1
19 N40 max -0.109 14 1.54 3 -0.279 15 0 15
20 min -1.267 3 0.285 13 -3.259 3 0 1
21 N38 max -0.111 14 1.447 3 3.229 3 0 15
22 min -1.244 3 0.267 15 0.277 13 0 1
23 N37 max -0.041 14 0.01 1 15 0.477 3 0 15
24 min -0.548 3 -0.047 9 0.029 13 0 1
25 Totals: max 1.908 6 16.844 3 1.908 15
26 min -1.908 12 3.177 14 -1.908 5
Envelope Beam Deflections
Member Label Span Location fftl v' finl
1 M17 1 max 3.196 -0.001
2 1 min 0 0
3 M18 1 max 2.622 0.001
4 1 min 8.392 0.053
5 M19 1 max 0.083 -0.001
6 1 min 0 -0.004
7 2 max 3.5 0
8 2 min 1 0
9 3 max 4 0
10 3 min 3.542 0
11 M20 1 max 1.5 -0.001
12 1 min 0 0
13 M21 1 max 0.5 0
14 1 min 0 0
15 2 max 3 0
16 2 min 0.542 0
17 3 max 3.75 -0.001
18 3 min 3.042 0
19 M22 1 max 2.875 -0.001
20 1 min 0 0
21 M23 1 max 0.083 -0.001
22 1 min 0 -0.001
23 2 max 3.5 0
24 2 min 1.042 0
25 3 max 4 0
26 3 min 3.542 0
27 M24 1 max 2.917 -0.001
28 1 min 0 0
29 M25 1 max 2.71 0.001
30 1 min 8.392 0.067
31 M26 1 max 1.619 -0.001
32 1 min 0 0
33 M27 1 max 2.885 0.001
34 1 min 8.392 0.054
35 M28 1 max 2.71 0.001
36 1 min 8.392 0.067
37 M29 1 max 0.125 -0.001
38 1 min 0 -0.004
RISA-30 Version 21 [ Aviara Stairs GARAGE.r3d]
Page 24
3/17/2023
4:58:20 PM
Checked By :
MY fk-ftl LC MZ [k-ftl LC
0 15 0 15
0 1 0 1
0 15 0 15
0 1 0 1
0 15 0 15
0 1 0 1
0 15 0 15
0 1 0 1
0 15 0 15
0 1 0 1
0 15 0 15
0 1 0 1
(n) L'/v' Ratio LC
NC 3
NC 1
NC 4
3773 3
NC 1
6632 3
NC 15
NC 1
NC 15
NC 1
NC 3
NC 1
NC 15
NC 1
NC 15
NC 1
NC 8
NC 1
NC 8
NC 1
NC 2
NC 1
NC 15
NC 1
NC 15
NC 1
NC 10
NC 1
NC 13
2999 3
NC 10
NC 1
NC 7
3707 3
NC 15
3004 3
NC 4
6164 3
Page 13
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
A Nl::MI:: TSGHf.:I\ {.:()MPAN"' Model Name:
Envelope Beam Deflections (Continued)
Member Label Span Location fftl
39 2 max 3.5
40 2 min 1
41 3 max 4
42 3 min 3.542
43 M30 1 max 1.375
44 1 min 0
45 M31 1 max 0.625
46 1 min 2
47 M32 1 max 3.333
48 1 min 2
Envelope Beam Deflection Checks
Beam Desian Rule Soan Defl finl Ratio LC Defl finl
1 M1 7 Tvoical 1 0 NC 1/DL\ 0
2 M18 T,mical 1 0.0009154 NC 1/DL\ 0.037
3 M1 9 Tvoical 1 -3.474e-5 NC 1<DL\ -0.002
4 2 -1.613e-21 NC 1/DL\ -3.39e-21
5 3 -4.406e-5 NC 1£DL) -9.89e-5
6 M20 Tvnical 1 1.084e-19 NC 1/DL\ -8.674e-19
7 M21 T1mical 1 -7.302e-23 NC 1IDL\ -3.716e-22
8 2 4.567e-21 NC 1/DL\ 9.904e-21
9 3 -0.000527 NC 1<DL\ -0.0009937
10 M22 Tvoical 1 0 NC 1/DL\ 0
11 M23 Tvnical 1 4.875e-21 NC 1/DL\ 1.052e-20
12 2 8.1 79e-22 NC 1/DL\ 1.969e-21
13 3 -4.612e-5 NC 1/DL\ -0.0001042
14 M24 Tvoical 1 2.168e-19 NC 1/DL\ 8.674e-19
15 M25 Tvnical 1 0.021 9627 1/DL\ 0.046
16 M26 Tvoical 1 0 NC 1/DL\ 0
17 M27 Tvnical 1 0.0009202 NC 1<DL\ 0.037
18 M28 Tvoical 1 0.021 9656 1/DL\ 0.046
19 M29 Tvoical 1 -3.776e-5 NC f<DL\ -0.003
20 2 -2.598e-21 NC 1/DL\ -5.974e-21
21 3 -4.612e-5 NC 1 <DL\ -0.0001042
22 M30 Tvoical 1 1.084e-19 NC 1/DL\ -6.505e-19
23 M31 Tvnical 1 0 NC 1/DL\ -0.008
24 M32 T,mical 1 0 NC 1/DL\ -0.008
Envelope A/SC 15TH (360-16): ASD Member Steel Code Checks
v' linl (n) L'/v' Ratio
0 NC
0 NC
0 NC
0 NC
-0.001 NC
0 NC
-0.001 NC
-0.011 4391
-0.001 NC
-0.01 1 441 0
Ratio LC Defl finl
NC 2<LL\ 0
5484 2/LL\ 0.053
9664 2<LL\ -0.004
NC 2/LL\ -5.003e-21
NC 2£LL\ -0.000143
NC 2/LL\ -6.505e-19
NC 2£LL\ -4.441e-22
NC 2<LL\ 1.447e-20
NC 2£LL\ -0.0009394
NC 2/LL\ -3.469e-18
NC 2/LL\ 1.54e-20
NC 2/LL\ 2.787e-21
NC 2/LL\ -0.0001503
NC 2<LL\ 8.674e-19
4356 2/LL\ 0.067
NC 2<LL\ 0
5386 2/LL\ 0.054
4361 2£LL\ 0.067
8958 2<LL\ -0.004
NC 2/LL\ -8.571e-21
NC 2<LL\ -0.0001503
NC 2/LL\ -6.505e-19
6302 2<LL\ -0.011
6328 2/LL \ -0.011
Page 25
3/17/2023
4:58:20 PM
Checked By :
LC
15
1
15
1
2
1
12
3
15
3
Ratio LC
NC 3/DL+LL
3773 3/DL+LL
6632 3<DL+LL
NC 3/DL+LL
NC 3£DL+LL
NC 3/DL+LL
NC 3£DL+LL'
NC 3/DL+LL
NC 3£DL+LL
NC 3/DL+LL
NC 3/DL+LL
NC 3/DL+LL
NC 3£DL+LL'
NC 3/DL+LL
2999 3/DL+LL
NC 3/DL+LL
3707 3/DL+LL
3004 3/DL+LL\
6164 3/DL+LL\
NC 3/DL+LL\
NC 3/DL+LL\
NC 3/DL+LL'
4391 3/DL+LL\
4410 3/DL+LU
Member Shape Code CheckLocfft LC Shear CheckLocfft Dir LC Pnc/om fk PnUom fk Mnvv/om fk-ft Mnzz/om lk-ft Cb Eon
1 M17 MC12X10.f 0.055 0 7 0.017 4.091 V 3 41.181 66.826 0.883 20.838 1 H1-1b
2 M18 MC12X10.f 0.338 8.392 6 0.039 8.392 V 3 28.393 66.826 0.883 20.838 1 H1-1 b
3 M19 MC12X10.f 0.317 0 6 0.056 0.5 z 6 41.565 66.826 0.883 20.838 1.62~ H1-1 b
4 M20 C8X11 .5 0.044 0.5 3 0.023 4 V 11 61.254 72.647 2.231 17.299 1 H1-1 b
5 M21 MC12X10.f 0.117 3 3 0.033 3 V 3 41 .565 66.826 0.883 20.838 1.551 H1-1b
6 M22 C8X11 .5 0.025 0.5 4 0.039 0 V 4 61.254 72.647 2.231 17.299 1 H1 -1b
7 M23 MC12X10.f 0.121 1 3 0.036 1 V 3 41 .565 66.826 0.883 20.838 1.721 H1-1b
8 M24 C8X1 1.5 0.042 2 3 0.048 4 V 8 61.254 72.647 2.231 17.299 1 H1-1b
9 M25 MC12X10.f 0.384 4.196 4 0.035 8.392 V 3 28.393 66.826 0.883 20.838 1 H1-1b
10 M26 MC12X10.f 0.089 2.045 5 0.017 4.091 V 3 41 .181 66.826 0.883 20.838 1 H1 -1 b
11 M27 MC12X10.f 0.335 8.392 6 0.039 8.392 V 3 28.393 66.826 0.883 20.838 1 H1-1 b
12 M28 MC12X10.f 0.407 4.109 8 0.035 8.392 V 3 28.393 66.826 0.883 20.838 1 H1-1b
13 M29 MC12X10.l 0.31 0 6 0.055 0.5 z 6 41.565 66.826 0.883 20.838 1.541 H1-1b
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d] Page 14
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
ANEME'fSCHF,K COMPANY Model Name:
Envelope A/SC 15TH (360-16): ASD Member Steel Code Checks (Continued)
Member Shaoe Code CheckLoc[ft LC Shear CheckLocrtt Dir LC Pnc/om [k PnUom [k
14 M30 C8X11 .5 0.051 0.5 3 0.023 0.5 V 3 61.254 72.647
15 M31 C4X7.25 0.084 2.083 3 0.018 3.5 V 3 40.989 45.916
16 M32 C4X7.25 0.085 2 3 0.017 0.5 V 3 40.989 45.916
RISA-30 Version 21 [ Aviara Stairs GARAGE.r3d ]
Mnvv/om [k-ft
2.231
0.969
0.969
Page 26
3/17/2023
4:58:20 PM
Checked By:
Mnzz/om [k-ft Cb Eqn
17.299 1 H1 -1b'
5.102 1 H1-1b
5.102 1 H1-1 b
Page 15
Page 27
ASD Joint Reactions
0.11 1.244/0.133
3.645 / 0.649
0.144
-0.536 I -3.822 -0.144 0.11
3-63510 qd!1191.1 .164
1.821 / 0.326
Envelope Only Solution
Reaction and Moment Units are kips and kip-ft (Enveloped)
IIIRISA Orie2 Engineering, Inc.
, ··~ ESY
-0.111
3.229 / 0.277
./ ~7
'•fOf.~O. O&) I 0.029 ,O.O!)--1 ">!U' / z, 7 il..267 ·,
'"-_ 1.794 ',....,~--0· -0.041 /-0.548
'--. ~o.01 -0.073
-o.o r -T ---o oga
2.04 / 0.357
SK-7
Mar 17, 2023 at 04:43 PM
Aviara Stairs GARAGE.r3d
Page 28
ASD Joint Reactions
3.229 / 0.277
11 / -1.244
0.477 I 0.029
1.794
-0.098
Envelope Only Solution
Reaction and Moment Units are kips and kip-ft (Enveloped)
IIIRISA Orie2 Engineering, Inc.
.. ,, ""~ ESY ~---------!
SK-8
Mar 17, 2023 at 04:43 PM
Aviara Stairs GARAGE.r3d
ASD Joint Reactions
Page 29
Landing Anchors to (E) CMU Wall
T = 3,259 lbs
Vx = 1,267 lbs
Vy = 1,540 lbs
-~0.576
~-
Envelope Only Solution
Reaction and Moment Units are kips and kip-ft (Enveloped)
IIIRISA Orie2 Engineering, Inc.
"'" ESY
~
SK-9
Mar 17, 2023 at 04:43 PM
Aviara Stairs GARAGE.r3d
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number ASD Joint Reactions
,\ Nf'METSCHEK COMPANY Model Name :
Envelope Node Reactions
Node Label X [kl LC Y lkl LC Z [kl LC MX lk-ftl
1 N34 max 1.806 10 1.958 3 0.017 15 0
2 min -0.094 12 0.345 12 -1.073 3 0
3 N35 max 0.089 10 -0.109 15 0.017 14 0
4 min -0.07 12 -0.857 3 -0.264 8 0
5 N33 max 1.794 10 2.041 3 1.035 3 0
6 min -0.098 12 0.357 12 -0.029 13 0
7 N36 max 0.091 6 -0.05 13 0.26 8 0
8 min -0.073 12 -0.5 3 -0.026 14 0
9 N17 max 0.11 14 1.821 3 -0.119 15 0
10 min -0.111 4 0.326 12 -1 .164 3 0
11 N21 max 0.144 14 3.635 3 -0.536 15 0
12 min -0.144 4 0.647 14 -3.822 3 0
13 N22 max 0.11 14 1.88 3 1.244 3 0
14 min -0.11 1 4 0.336 12 0.133 13 0
15 N24 max 0.144 6 3.645 3 3.833 3 0
16 min -0.144 12 0.649 14 0.537 13 0
17 N39 max -0.048 14 0.279 3 -0.03 15 0
18 min -0.576 3 0.034 15 -0.49 3 0
19 N40 max -0.109 14 1.54 3 -0.279 15 0
20 min -1 .267 3 0.285 13 -3.259 3 0
21 N38 max -0.111 14 1.447 3 3.229 3 0
22 min -1 .244 3 0.267 15 0.277 13 0
23 N37 max -0.041 14 0.011 15 0.477 3 0
24 min -0.548 3 -0.047 9 0.029 13 0
25 Totals: max 1.908 6 16.844 3 1.908 15
26 min -1 .908 12 3.177 14 -1.908 5
RISA-30 Version 21 [ Aviara Stairs GARAGE.r3d ]
LC MY lk-ftl LC
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
15 0 15
1 0 1
Page 30
3/17/2023
4:43:17 PM
Checked By :
MZ lk-ft LC
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
0 15
0 1
Page 1
Orie2 Engineering
Strucwmt E11g111eers
9750 Mnmar Road, Sur.e 310
S..n Oi'9(), CA 92126
Fa, (858) -• 1
PRECAST CONCRETE TREAD "STEPTREAD" (BY "STEPSTONE")
N.L.
MC12X1O.6
w STRINGER\
~12"LT.WT.CONCRETE A 8 OVER 10 GA. rt ! I
~ L2X2Xl/8
Project No. : 158.033-23
PROJECT: Aviara-lFA-Stairs Garage
Page 31
DATE : 3/16/23
BY: ESY
Landing Anchors to (E) CMU Wall
L3X3Xl/4X0 '-6
ANGLE
CMU WALL
2"L T. WT . CONCRETE
OVER 10 GA. It
C4X7.25 -----
~fiJ>_ =I
L2X2Xl/8 j, 4 ~ 3 j. ---~ 3 SIDES
L3X3Xl/4 __ W/3/4"0 X 4 1/2" NOMINAL EMBEDMENT HILT! KB-TZL EXPANSION ANCHORS
(ICC-ESR 4266)
SECTION-2
PRECAST CONCRET~ TREAD "STEPTREAD"' (BY "STEPSTONE")
MC12Xl0.6 STRINGE
SECTION-3
T = 3,259 lbs
Vx = 1,267 lbs
Vy = 1 ,540 lbs
ANGLE
V = ( 1267"2 + 1540"2 )"1/2 = 1,995 lbs
s = 8"
0 N
.-t
-------1 --
1 4
Load reduction factor= 0.5 + ( 8 -4 ) / ( 27 -4 ) x 0.5 = 0.587
Tallow = 0.587 x 3810 x 3 anchors= 6,709 lbs
L3X3Xl /4 W/3/4"0 x4_1/2"
NOMINAL EMBEDMENT , HILT! KB-TZ2 EXP. ANCHORS 411/.2 EMBEDMENT (ICC-ESR 4266)
SECTION -8
Vallow= 0.587 x 4090 x 3 anchors= 7,202 lbs
T I T allow= 3,259 / 6,709 lbs= 0.49 < 1.0
V /Vallow= 1,995 / 7,202 lbs= 0.28 < 1.0
TIT allow + V /Vallow = 0.77 < 1.0
OK
OK
OK
Page 32
TABLE 3A-ALLOWABLE ADHESIVE BOND TENSION LOADS FOR THREADED RODS AND REINFORCING BARS IN THE FACE OF
GROUT-FILLED CONCRETE MASONRY UNITS (POUNDS)1•2•7•8•9•11•12•13
Anchor Load @ Spacing4 Edge Distances
Diameter Embedment Critical, Minimum, Critical, Minimum,
(inches), or (inches)3 Ccr and Load Reduction Load Reduction
Ser Ser Smln Factor at Sm1n 6 Cc, Cmin Factor at Cm1n 6
Rebar Size Cinches) (inches) (inches) (inches)
3/a or No. 3 33/a 1240 13.5 4 0.70 12 4 0.80
1/2 or No. 4 41/2 2035 18 4 0.70 20 4 0.76
5ta or No. 5 55/a 2840 22.5 4 0.50 20 4 0.71
I 3/4 or No. 6 63/4 3810 27 4 0.50 20 4 0.66
TABLE 3B-ALLOWABLE ADHESIVE BOND SHEAR LOADS FOR THREADED RODS AND REINFORCING BARS IN THE FACE OF
GROUT-FILLED CONCRETE MASONRY UNITS (POUNDS)1•2•7•8•9•10•11•12•13
Spacing• Edge Distances
Anchor Load Load Reduction Factor at Cm1n 6
Embedment Load @ Critical, Minimum, Critical, Minimum, Diameter (inches)3 Cc, and Sc, Ser Smln
Reduction Ccr Cmin Factor at (inches) (inches) (inches) (inches) (inches) Load 6 Load Parallel Smin Perpendicular
to Edae to Edge
3ta or No. 3 33/a 850 13.5 4 1.00 12 4 0.88 1.00
1/2 or No. 4 41/2 1495 18 4 1.00 12 4 0.49 1.00
5/. or No. 5 5s/. 2615 22.5 4 0.50 20 4 0.40 0.78
3/4 or No. 6 63/4 4090 27 4 0.50 20 4 0.26 0.60
For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N, 1 psi = 6.89 kPa.
The following footnotes apply to both Tables 3A and 3B:
1 All values are for anchors installed in fully grouted concrete masonry with minimum masonry strength of 1500 psi. Concrete masonry units must be light-. medium-.
or normal-weight conforming to ASTM C90. Allowable loads have been calculated using a safety factor of 5.
2 Anchors may be installed in any location in the face of the masonry wall (cell, web, joints). Anchors are limited to one per masonry cell.
3 Embedment depth is measured from the outside face of the concrete masonry unit.
4 The critical spacing, Sc,, is the anchor spacing where full load values in the table may be used. The minimum spacing, Smon, is the minimum anchor spacing for which
values are available and installation is recommended. Spacing is measured from the center of one anchor to the center of an adjacent anchor.
5 The critical edge distance, Cc,, is the edge distance where full load values in the table may be used. The minimum edge distance, Cm.,, is the minimum edge distance
for which values are available and installation is permitted. Edge distance is measured from the center of the anchor to the closest edge (See Figure 2).
6 Load reduction factors are multiplicative; both spacing and edge distance load reduction factors must be considered.
7 Load values for anchors installed at less than s" and Cc, must be multiplied by the appropriate load reduction factor based on actual edge distance (c) or spacing (s).
8 Linear interpolation of load values between minimum spacing (smin) and critical spacing (Sc,) and between minimum edge distance (Cm1n) and critical edge distance
(Cc,) is permitted.
9 Concrete masonry thickness must be equal to or greater than 1.5 times the anchor embedment depth. EXCEPTION: the 5/8-inch-and the
3/4-inch-diameter anchors and No.5 and No. 6 reinforcing bars may be installed in minimum nominally 8-inch-thick concrete masonry.
10 When using the basic load combinations in accordance with IBC Section 1605.3.1, tabulated allowable loads must not be increased for seismic or wind loading.
When using the alternative basic load combinations in the 2009 or 2006 IBC Section 1605.3.2 that include seismic or wind loads, tabulated allowable loads may be
increased, or the alternative basic load combinations may be reduced according to Table 2. For the 2015 and 2012 IBC, the allowable loads or load combinations
must not be adjusted. 11 Allowable loads must be the lesser of the adjusted masonry or bond values tabulated above and the steel values given in Table 10.
12 Tabulated allowable bond loads must be adjusted for increased base material temperatures in accordance with Figure 1, as applicable.
13 For combined loading, see Section 4.1.2.
LRFD Joint Reactions
Stringer Anchors to Embed Plate\
T = 5,650 lbs
Vy = 5,376 lbs
Vx = 205 lbs
0.158 1.835 / 0.133
1 5.376 I o.649
Stringer Bottom Anchors to (E) Concrete Slab
Vz = 5,634 lbs
Vx = 205 lbs
0.205
-0.536 -5.634 -0.205
0.158
5-359 '0-6~d.119 /-1.717
2.686 / 0.326
Envelope Only Solution
Reaction and Moment Units are kips and kip-ft (Enveloped)
IIIRISA Orie2 Engineering, Inc.
•• , « ESY ,----------!
Page 33
4.76 / 0.277
/ •• ~68 ~ -~-;~,~!I~ I _ Q..lQ4 IO 029
/ 2. : 32'f•.Q_7.67 o. f4~ o>~M
'-.... '--.,....._ 2.612~--0.041 /-0.808 ·, ,0 . -0.103 ·, ,_ ,
-0.0 -0.116
3.0 I 0.357
SK-10
Mar 17, 2023 at 04:51 PM
Aviara Stairs GARAGE.r3d
IIIRISA
Company : Orie2 Engineering, Inc.
A NEMETSCHEK COMPANY
Designer : ESY
Job Number
Model Name:
Envelope Node Reactions
Node Label X fkl LC Y fkl
1 N34 max 2.638 17 2.886
2 min -0.11 22 0.345
3 N35 max 0.137 20 -0.109
4 min -0.099 22 -1 .267
5 N33 max 2.612 17 3.01
6 min -0.1 16 22 0.357
7 N36 max 0.14 20 -0.05
8 min -0.103 22 -0.736
9 N17 max 0.158 24 2.686
10 min -0.158 18 0.326
11 N21 max 0.205 24 5.359
12 min -0.205 18 0.647
13 N22 max 0.158 24 2.774
14 min -0.158 18 0.336
15 N24 max 0.205 20 5.376
16 min -0.205 22 0.649
17 N39 max -0.048 14 0.413
18 min -0.849 17 0.034
19 N40 max -0.109 14 2.27
20 min -1.867 17 0.285
21 N38 max -0.111 14 2.132
22 min -1 .834 17 0.267
23 N37 max -0.041 14 0.015
24 min -0.808 17 -0.068
25 Totals: max 2.726 20 24.833
26 min -2.726 22 3.177
RISA-30 Version 21
LRFD Joint Reactions
LC Z [kl LC MX fk-ftl
17 0.017 15 0
12 -1.583 17 0
15 0.021 24 0
17 -0.382 17 0
17 1.526 17 0
12 -0.029 13 0
13 0.366 17 0
17 -0.034 24 0
17 -0.119 15 0
12 -1.717 17 0
17 -0.536 15 0
14 -5.634 17 0
17 1.835 17 0
12 0.133 13 0
17 5.65 17 0
14 0.537 13 0
17 -0.03 15 0
15 -0.722 17 0
17 -0.279 15 0
13 -4.803 17 0
17 4.76 17 0
15 0.277 13 0
25 0.704 17 0
17 0.029 13 0
17 2.726 25
14 -2. 726 19
[ Aviara Stairs GARAGE.r3d ]
LC MY fk-ftl LC
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
25 0 25
1 0 1
Page 34
3/17/2023
4:51:57 PM
Checked By :
MZ fk-ft LC
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
0 25
0 1
Page 1
Page 35
LRFD Overstrength Joint Reactions
0.158 1.037 I 0.206
2.675 I 0.976
0.205
-0.817 / -3 019 -0.205
0.158
2.669 / 0.973
Envelope Only Solution
-0.186 /-0.98
1.331 /0.49
Reaction and Moment Units are kips and kip-ft (Enveloped)
IIIRISA Orie2 Engineering, Inc.
,.,., , .. ,.,, ESY
2.803 / 0.44
/ -0.049 /4 -0.f I~~,, -0..4~ 1 / 0 049
/ 1Cl'54_/Q.4 0 ,4_ cY.~t2
'---, 1.897 '-~-------. ~ -0.0651 -0.484 •-.... ,....,_ o. m -0.103
', .
-0.0 -0.116
1.50 7 0.537
SK-13
Mar 17, 2023 at 04:56 PM
Aviara Stairs GARAGE.r3d
IIIRISA
A NEMETSCHEK COMPANY
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name : LRFD Overstrength Joint Reactions
Envelope Node Reactions -Overstrength or Capacity Limit
Node Label X [kl LC Y fkl LC Z fkl LC MX fk-ft LC
1 N34 max 1.903 28* 1.45 28* 0.01 33• 0 33•
2 min -0.11 30• 0.519 30• -1.083 21· 0 26*
3 N35 max 0.137 28* -0.167 33• 0.021 32• 0 33•
4 min -0.099 30* -0.677 27* -0.281 26* 0 26*
5 N33 max 1.897 28* 1.507 28* 1.063 29• 0 33•
6 min -0.116 30• 0.537 30* -0.028 31* 0 26*
7 N36 max 0.14 28* -0.078 31* 0.282 26* 0 33•
8 min -0.103 30* -0.43 29• -0.034 32* 0 26*
9 N17 max 0.158 32• 1.331 28* -0.186 33• 0 33*
10 min -0.158 26* 0.49 30• -0.98 27* 0 26*
11 N21 max 0.205 32• 2.669 26* -0.817 33* 0 33•
12 min -0.205 26* 0.973 32* -3.019 27* 0 26*
13 N22 max 0.158 32* 1.373 28* 1.037 29* 0 33*
14 min -0.158 26* 0.505 30* 0.206 31 * 0 26*
15 N24 max 0.205 28* 2.675 26* 3.026 29* 0 33*
16 min -0.205 30* 0.976 32• 0.819 31• 0 26*
17 N39 max -0.076 32* 0.218 27* -0.049 33• 0 33*
18 min -0.502 26* 0.052 33• -0.443 27* 0 26*
19 N40 max -0.172 32* 1.122 29* -0.442 33• 0 33•
20 min -1.101 26* 0.428 31* -2.826 27* 0 26*
21 N38 max -0.175 32• 1.054 27* 2.803 29• 0 33*
22 min -1.072 26* 0.4 33• 0.44 31 • 0 26*
23 N37 max -0.065 32* 0.015 33* 0.431 29• 0 33*
24 min -0.484 26* -0.049 27* 0.049 31* 0 26*
25 Totals: max 2.726 28* 12.128 26* 2.726 33*
26 min -2.726 30• 4.765 32* -2.726 27*
RISA-3D Version 21 [ Aviara Stairs GARAGE.r3d ]
MY fk-ft LC
0 33•
0 26*
0 33*
0 26*
0 33*
0 26*
0 33•
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33•
0 26*
0 33•
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
Page 36
3/17/2023
4:57:05 PM
Checked By :
MZ [k-ftl LC
0 33*
0 26*
0 33*
0 26*
0 33•
0 26*
0 33•
0 26*
0 33*
0 26*
0 33*
0 26*
0 33*
0 26*
0 33•
0 26*
0 33*
0 26*
0 33*
0 26*
0 33•
0 26*
0 33*
0 26*
Page 1
Orie2 Engineering Project No. : 158.033-23
Structural E11gmeers
9750 Mnmar R06d, Suite 310
San Diego. CA 92126 PROJECT : Aviara-lFA-Stairs Garage
Fax (85&) 586-Q91 I
Stringer Bottom Anchors to (E) Concrete Slab
PRECAST CONCRETE TREAD "STEPTR EAD"
(BY "STEPSTON E")
11 GA.
CONC .
L4X3Xl(.4X O'-7" fL LH) W/2 -1/2 '0X 3" NOM NAL EMBED
HILTI KB-TZ2 EXPANSION ANCHORS
(ICC ESR-4266)
MC12X1O .6
STRINGER
J 4 j,
N.L.
SECTION-1
Stringer Bottom Anchors to (E) Concrete Slab
Vz = 5,634 lbs
Vx = 205 lbs
Page 37
DATE: 3/16/23
BY : ESY
CAP PL 1/4"
ca
::i
Vl
u z
0 u
z . UJ ~ 0
UJ ca ~ LJ.J
1:115;.1
Hilti PROFIS Engineering 3.0.84
www.hilti.com ------
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter:
Item number:
Effective embedment depth:
Material:
Evaluation Service Report:
Issued I Valid:
Proof:
Stand-off installation:
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 17, 2023
Kwik Bolt TZ2 -CS 1/2 (2 1/2) hnom3
2210254 KB-TZ2 1/2x3 3/4
hef.act = 2.500 in., hnom = 3.000 in.
Carbon Steel
ESR-4266
12/17/2021 I 12/1/2023
Design Method ACI 318-19 / Mech
eb = 0.000 in. (no stand-off); t = 0.250 in.
Page:
Specifier:
E-Mail:
Date:
Page 38
Daniel Fisher
dfisher@orie2.com
3/18/2023
----t)
-
Anchor plateR : I, x IY x t = 3.000 in. x 6.000 in. x 0.250 in.; (Recommended plate thickness: not calculated)
Profile:
Base material:
Installation:
Reinforcement:
Seismic loads (cat. C, D, E, or F)
no profile
cracked concrete, 2500, fc' = 2,500 psi; h = 12.000 in.
hammer drilled hole, Installation condition: Dry
tension: not present, shear: not present; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar
Tension load: yes (17.10.5.3 (d))
Shear load: yes (17.10.6.3 (c))
R -The anchor calculation is based on a rigid anchor plate assumption.
Geometry [in.] & Loading [lb, in.lb]
-~
---------·----
\--c<-r
\~-t ;_
\---------z l . y
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
,:,,s~•
Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 17, 2023
Page:
Specifier:
E-Mail:
Date:
1.1 Design results
Case Description
Combination 1
Forces [lb]/ Moments [in_.lb~] ____ _ Seismic
yes
2 Load case/Resulting anchor forces
Anchor reactions [lb)
Tension force: (+ Tension, -Compression)
Anchor Tension force
0
Shear force
2,819
2,819
Shear force x
103
2 0 103
max. concrete compressive strain: -[%o]
max. concrete compressive stress: -[psi]
resulting tension force in (x/y)=(0.000/0.000): 0 [lb]
resulting compression force in (x/y)=(0.000/0.000): O [lb]
N = O; v. = 205; Vy = 5,634;
M. = 0; My = 0; Mz = 0;
Shear force y
2,817
2,817
Anchor forces are calculated based on the assumption of a rigid anchor plate.
3 Tension load
Load Nu• [lb) Capacity ♦ N0 [lb]
Steel Strength• N/A N/A
Pullout Strength• N/A N/A
Concrete Breakout Failure .. N/A N/A
• highest loaded anchor ••anchor group (anchors in tension)
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Utilization 13N = Nu.J♦
N/A
N/A
N/A
Nn
Page 39
2
Daniel Fisher
dfisher@orie2.com
3/18/2023
Max. Util. Anchor[%]
64
Status
N/A
N/A
N/A
2
V
1 : i i 5 • • ----------------------
Hilti PROFIS Engineering 3.0.84
www.hilti.com ----------
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 17, 2023
Fastening point:
4 Shear load
Load V ua [lb]
Steel Strength* 2,819
Steel failure (with lever arm)* N/A
Pryout Strength** 5,638
Concrete edge failure in direction ** N/A
• highest loaded anchor **anchor group (relevant anchors)
4.1 Steel Strength
V sa.eq = ESR value
4> v ,tee1 ~ v u.
Variables
__ A~v [in.2]
0.10
Calculations
v,. [lb]
6,878
Results
~• [lb]
6,878
refer to ICC-ES ESR-4266
ACI 318-19 Table 17.5.2
futa [psi] 0 v,seis
114,004 1.000
4> steel q> nonductile
0.650 1.000
Page:
Specifier:
E-Mail:
Date:
Capacity ♦ Vn [lb]
4,471
N/A
8,910
N/A
4>'--V_.,,a,,,,e.,._9__,__[I--'b],_ ___ Vua [lb]
4,471 2,819
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Utilization 13v = Vua/♦ vn
64
N/A
64
N/A
Page 40
3
Daniel Fisher
dfisher@orie2.com
3/18/2023
Status
OK
N/A
OK
N/A
3
1 : i i S • i _____________________ _
Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 17, 2023
Fastening point:
4.2 Pryout Strength
V cpg = kcp [ (::c:) IJI ec,N IJI ed.N IJI c,N 1J1 cp,N Nb ]
<I> v cpg ~ v u.
ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
ANcO = 9 h!t
IJI ec,N = ( 1+ ~ e~ ) $ 1.0
3 het
"' ed.N = 0 7 + 0 3 ( Ca.min ) < 1 0 " • • 1.5h0t -•
ljl cp,N $ 1.0
Variables
hef [in.]
2 2.500
Cac [in.] ljl c,N ------=-
1.000
Calculations
__ ANc [in.2]
86.25
Results
Vcpg [lb]
12,728
6.750
ANc0 [in.2]
56.25
q> ooncrele
0.700
ec1,N [in.]
0.000
kc
21
\V eci,N
1.000
cf>seismk:
1.000
Page:
Specifier:
E-Mail:
Date:
ACI 318-19 Eq. (17.7.3.1b)
ACI 318-19 Table 17.5.2
ACI 318-19 Eq. (17.6.2.1.4)
ACI 318-19 Eq. (17.6.2.3.1)
ACI 318-19 Eq. (17.6.2.4.1b)
ACI 318-19 Eq. (17.6.2.6.1b)
ACI 31 8-19 Eq. (17.6.2.2.1)
ec2 N [in.] Ca min [in.]
0.000
"'a
1.000 2,500
IJI ec2.N ljl ed,N
1.000 1.000
<f>nonduclilo <I> Ve [lb]
1.000 8,910
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
IJlcp,N
1.000
Vua [lb]
5,638
Page 41
4
Daniel Fisher
dfisher@orie2.com
3/18/2023
Nb [lb]
4,150
4
I:11S.-I
Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
5 Warnings
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 17, 2023
Page:
Specifier:
E-Mail:
Date:
Page 42
5
Daniel Fisher
dfisher@orie2.com
3/18/2023
The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered -the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The
proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential
concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout
or pryout strength governs.
Refer to the manufacturer's product literature for cleaning and installation instructions.
For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/
"An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-19, Chapter 17, Section
17.10.5.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the
case, the connection design (tension) shall satisfy the provisions of Section 17.10.5.3 (b), Section 17.10.5.3 (c), or Section 17.10.5.3 (d). The
connection design (shear) shall satisfy the provisions of Section 17.10.6.3 (a), Section 17.10.6.3 (b), or Section 17.10.6.3 (c)."
Section 17 .10.5.3 (b) / Section 17 .10.6.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile
yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.10.5.3 (c) / Section 17.10.6.3
(b) waive the ductility requirements and require the anchors to be designed for the maximum tension/ shear that can be transmitted to the
anchors by a non-yielding attachment. Section 17.10.5.3 (d) / Section 17.10.6.3 (c) waive the ductility requirements and require the design
strength of the anchors to equal or exceed the maximum tension/ shear obtained from design load combinations that include E, with E increased
by w0.
Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI
318-19, Section 26.7.
Fastening meets the design criteria!
Input data and results must be checked for conformity with the existing conditions and for plausibiMy!
PROFIS Engineering ( c ) 2003-2023 Hilli AG, FL-9494 Schaan Hilli is a registered Trademark of Hilli AG, Schaan
5
•=iiS•• Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
6 Installation data
Profile: no profile
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 17, 2023
Hole diameter in the fixture: d1 = 0.562 in.
Plate thickness (input): 0.250 in.
Recommended plate thickness: not calculated
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions for use is
required.
Page:
Specifier:
E-Mail:
Date:
Page 43
6
Daniel Fisher
dfisher@orie2.com
3/18/2023
Anchor type and diameter: Kwik Bolt TZ2 -CS 1/2 (2 1/2)
hnom3
Item number: 2210254 KB-TZ2 1/2x3 3/4
Maximum installation torque: 602 in.lb
Hole diameter in the base material: 0.500 in.
Hole depth in the base material: 3.250 in.
Minimum thickness of the base material: 5.000 in.
Hilti KB-TZ2 stud anchor with 3 in embedment, 1/2 (2 1/2) hnom3, Carbon steel, installation per ESR-4266
6.1 Recommended accessories
Drilling
Suitable Rotary Hammer
• Properly sized drill bit
Coordinates Anchor [in.)
Anchor x __ _.:__Y ___ c .•
1 0.000 -2.000
2 0.000 2.000
Cleaning
• Manual blow-out pump
JL y
1.500 1.500 -
0 0 C?
C \? ~
..J
0 0 0 ..f
1
0 0 C?
~
1.500 1.500 -
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of H1lti AG, Schaan
-
0 0
C? "'
~ .,..
0 0 0 <')
X
Setting
Torque controlled cordless impact tool
Torque wrench
Hammer
6
1:115,.1
Hilti PROFIS Engineering 3.0.84
www.hilti.com -------
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 17, 2023
Fastening point:
7 Remarks; Your Cooperation Duties
Page:
Specifier:
E-Mail:
Date:
Page 44
7
Daniel Fisher
dfisher@orie2.com
3118/2023
Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each
case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data
or programs, arising from a culpable breach of duty by you.
Input data and results must be checked for conformity with the existing conditions and ror plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG. FL-9494 Schaan Hilti is a registered Trademark of Hilti AG. Schaan
7
Orie2 Engineering
Strnctural Engineers
9750 M••mar Road, Sui:e 310
san Diego. CA 92126
Fax (856) 586-0911
Project No. : 158.033-23
PROJECT: Aviara-lFA-Stairs Garage
Stringer Anchors to Embed Plate
Page 45
DATE: 3/16/23
BY : ESY
v 2 'l 4 v 2.., TOP OF
CONCRETE SLAB
MC12X1O.6
STRINGER
1 ~ ~ 1
: I :
~
~
\
EMBED PL3 /8X8X8
/ 4-5/8"0 X 9" HEADED STUDS ~
11 GA . ANGLE
(TYP)
SECTION-?
PRECAST CONCRETE TREAD "STEPTREAD" (BY "STEPSTONE")
4 1/s
1/4" END PL -r------1' ~-
TOP OF.
N. L.
"'E CONC. > SLAB
N
+---_.__----.11.--~I
-----11=:=:===lln====r-::
IV)
llGA ANGLE (TYP)
L2X2Xl/8
EMBED PL3 /8X8X8
W/ 4-5/8"0 X 9" HEADED STUDS
1 4
SECTION-4
Stringer Anchors to Embed Plate\
T = 5,650 lbs
Vy = 5,376 lbs
Vx = 205 lbs
TYP.3 SIDES
TYP .3
SIDES
PRECAST CONCRETE TREAD "STEPTREAD "
(BY "STEPSTONE")
MC12X1O.6 STRIN GER
,:,,s.,
Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter:
Item number:
Effective embedment depth:
Material:
Evaluation Service Report:
Issued I Valid:
Proof:
Stand-off installation:
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 18, 2023 (1)
AWS 01.1 GR. B 5/8
not available
h01 = 12.000 in.
Hilti Technical Data
-I -
Design Method ACI 318-19 / CIP
eb = 0.000 in. (no stand-off); t = 0.500 in.
Page:
Specifier:
E-Mail:
Date:
l
Page 46
Daniel Fisher
dfisher@orie2.com
3/18/2023
\
Anchor plateR: I, x IY x t = 7.500 in. x 8.000 in. x 0.500 in.; (Recommended plate thickness: not calculated)
Profile:
Base material:
Reinforcement:
no profile
cracked concrete, 3000, fc' = 3,000 psi; h = 420.000 in.
tension: present, shear: present; anchor reinforcement: shear
edge reinforcement: > No. 4 bar
R -The anchor calculation is based on a rigid anchor plate assumption.
Geometry [in.] & Loading [lb, in.lb]
X
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilli AG, Schaan
i : i i 5 ~ i _____________________ _
Hilti PROFIS Engineering 3.0.84
www.hilti.com -----
Company: Orie2 Engineering Inc Page:
Address: Specifier:
Phone I Fax: 18583359452 I E-Mail:
Design: Concrete -Mar 18, 2023 ( 1) Date:
Fastening point:
1.1 Design results
Case Description
Combination 1
_________ F_o_rces [lb]/ Moments [in.lb]
2 Load case/Resulting anchor forces
Anchor reactions [lb]
Tension force: (+ Tension, -Compression)
N = 5,650; Vx = 5,376; Vy= 205;
Mx = 0; My = 0; M2 = 0;
Anchor Tension force Shear force Shear force x Shear force y
1,412 1,345 1,344 51
2 1,412 1,345 1,344 51
3 1,412 1,345 1,344 51
4 1,412 1,345 1,344 51
max. concrete compressive strain: -[%o]
max. concrete compressive stress: -(psi]
resulting tension force in (x/y)=(0.000/0.000): 5,650 [lb]
resulting compression force in (x/y)=(0.000/0.000): 0 [lb]
Anchor forces are calculated based on the assumption of a rigid anchor plate.
3 Tension load
Steel Strength*
Pullout Strength*
Concrete Breakout Failure**
Concrete Side-Face Blowout, direction x-**
Load N0• (lb]
1,412
1,412
5,650
2,825
* highest loaded anchor **anchor group (anchors in tension)
Capacity ♦ N0 (lb]
14,966
15,456
7,058
18,387
Input data and results must be checked for conformity with the existing conditions and for plaus1bil1ty!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Seismic
no
,1.y
0 3
"\
Tension
0 1
Utilization f3N = N0.lf N"
10
10
81
16
Page 47
2
Daniel Fisher
dfisher@orie2.com
3/18/2023
Max. Util. Anchor [%]
92
0 4
~ '){
~
0 2
Status
OK
OK
OK
OK
2
1 : i i 5 ~ i _____________________ _
Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
3.1 Steel Strength
Ns• = Ase,N fu,a
<P Nsa ::?: Nua
Variables
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 18, 2023 (1)
ACI 318-19 Eq. (17.6.1 .2)
ACI 318-19 Table 17.5.2
Ase.,,N--'-'--[in_.-'
2
]'-----~f"='•~[_psi] __
0.31 65,000
Calculations
N5.[l_b] __
19,955
Results
N58 [lb]._ __
19,955
<P steel <P_N...,_sa,.__[=--lb...:.] ____ N0• [lt1
0.750 14,966 1,412
3.2 Pullout Strength
NpN = 'V c.p NP ACI 318-19 Eq. (17.6.3.1)
NP = 8 Abrg fc ACI 318-19 Eq. (17.6.3.2.2a)
<P NpN ::?: Nua ACI 318-19 Table 17.5.2
Variables
\jl c,p Abrg [in.2] A a fc [psi]
1.000 0.92 1.000 3,000
Calculations
NP [lb]
22,080
Results
NJ>n [lb] cl> concrete <P NI!!) [lb] N0• [lb]
22,080 0.700 15,456 1,412
Input data and results must be checked for conformity with lhe existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilli AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Page:
Specifier:
E-Mail:
Date:
Page 48
3
Daniel Fisher
dfisher@orie2.com
3/18/2023
3
1 : i i 5 • 1 _____________________ _
Hilti PROFIS Engineering 3.0.84
www.hilti.com -----Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 18, 2023 (1)
Fastening point:
3.3 Concrete Breakout Failure
Ncbg = (:Ne ) ljl ec,N ljl ec.N ljl c,N ljl cp,N Nb
NcO
q, Ncbg ~ Nua
ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
ANcO = 9 h!,
ljl ec.N = C +: e~) S 1.0
3 h01
1j1 ec,N = 0.7 + 0.3 ( ~-·sh:) s 1.0
'V cp.N
Variables
h01 [in.]
12.000
~ [in.]
Calculations
~c[in.2]
300.00
Results
NcbQ [lb]
9,410
~[in.]
0.000
kc
16
ANc0 [in.2]
1,296.00
4> conccete
0.750
ecwJin.]
0.000
"-a
1.000
ljl ec1,N
1.000
q, Ncbg~
7,058
Page:
Specifier:
E-Mail:
Date:
ACI 318-19 Eq. (17.6.2.1b)
ACI 318-19 Table 17.5.2
ACI 318-19 Eq. (17.6.2.1.4)
ACI 318-19 Eq. (17.6.2.3.1)
ACI 318-19 Eq. (17.6.2.4.1b)
ACI 318-19 Eq. (17.6.2.6.1b)
ACI 318-19 Eq. (17.6.2.2.3)
c. min [in.] ljl c,N
2.250 1.000
fc [psi]
3,000
ljl ec2,N ~/ ed,N
1.000 0.737
Nua [lb]
5,650
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROF IS Engineering ( c) 2003-2023 Hilti AG. FL-9494 Schaan Hilti is a registered Trademark of Hilli AG, Schaan
ljlcp,N
1.000
Page 49
4
Daniel Fisher
dfisher@orie2.com
3/18/2023
Nb (lb]
55,121
4
1:115;.1
Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 18, 2023 ( 1)
3.4 Concrete Side-Face Blowout, direction x-
N sb = 160 C31 ~ A.3 ~
N sbg = ag,oup Nsb
<j) N sbg ~ Nua
ACI 318-19 Eq. (17.6.4.1)
ACI 318-19 Eq. (17.6.4.2)
ACI 318-19 Table 17.5.2
Page:
Specifier:
E-Mail:
Date:
ag,oup = ( 1 + 6 ~.J see ACI 318-19, Section 17.6.4.2, Eq. (17.6.4.2)
Variables
c31 [in.) C32 [in.) ~' [in.2
] 1-. a re [psi]
2.250 0.92 1.000 3,000
Calculations
ex.group N,b (lb]
1.296 18,913
Results
N,bg [lb) 4> concrete <I> N•!!ll [lb] N ua,edge [lb]
24,517 0.750 18,387 2,825
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
s [in.)
4.000
Page 50
5
Daniel Fisher
dfisher@orie2.com
3/18/2023
5
,:,,s.,
Hilti PROFIS Engineering 3.0.84
www.hilti.com ----
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 18, 2023 (1)
Fastening point:
4 Shear load
Load V ua [lb]
Steel Strength* 1,345
Steel failure (with lever arm)* N/A
Pryout Strength** 5,380
Concrete edge failure in direction ** 1 N/A
• highest loaded anchor **anchor group (relevant anchors)
1 Shear Anchor Reinforcement has been selected!
4.1 Steel Strength
V sa = Ase.V futa
<I> v.,e.1;:: v ".
Variables
ACI 318-19 Eq. (17.7.1.2a)
ACI 318-19 Table 17.5.2
A=se~v~['---in_. 2..c] ___ -'futa [psi]
0.31 65,000
Calculations
Vsa (lb)
19,955
Results
~.(lb)
19,955
<j> steel
0.650
<j> V sa'-'l_lb.:..) __
12,971
Page:
Specifier:
E-Mail:
Date:
Capacity ♦ V" (lb)
Vua [l_b)~--
1,345
12,971
N/A
13,174
N/A
Input data and results must be checked for conformity with the el(isting conditions and for plausibility\
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Utilization Pv = V ua/♦ v n
11
N/A
41
N/A
Page 51
6
Daniel Fisher
dfisher@orie2.com
3/18/2023
Status
OK
N/A
OK
N/A
6
1:115;.1
Hilti PROFIS Engineering 3.0.84
www.hilti.com ------
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 18, 2023 (1)
Fastening point:
4.2 Pryout Strength
Vcpg = kcp [ (:::) lj/ ec,N lj/eo,N lj/c,N lj/cp,N Nb ]
cl> v cpg ~ v u.
ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
ANcO = 9 h!t
lj/ ec,N = (, +: e~ ) S 1.0
3 het
lj/ ed,N = 0.7 + 0.3 ( ~.-5h:) s 1.0
lj/ cp.N
Variables
kcp
2
lj/ c,N
1.000
Calculations
ANc [in.2]
300.00
Results
~~_lib]
18,820
s 1.0
h01 [in.]
12.000
c.c [in.]
ANcO [in.2]
1,296.00
<f> concrete
0.700
ec, N_ [in.]
0.000
kc
16
lj/ ec1,N
1.000
cj> V~[lb]
13,174
Page:
Specifier:
E-Mail:
Date:
ACI 318-19 Eq. (17.7.3.1b)
ACI 318-19 Table 17.5.2
ACI 318-19 Eq. (17.6.2.1.4)
ACI 318-19 Eq. (17.6.2.3.1)
ACI 318-19 Eq. (17.6.2.4.1b)
ACI 318-19 Eq. (17.6.2.6.1b)
ACI 318-19 Eq. (17.6.2.2.3)
ec2 N [in.] Ca min [in.] __
0.000 2.250
A a fc [psi]
1.000 3,000
lj/ec2.N lj/ed,N
1.000 0.737
Vua [lb)
5,380
5 Combined tension and shear loads, per ACI 318-19 section 17.8
PN -----0.801
Pv
0.408
s ____ U_t_ilization PN,v [%]
5/3 92
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilli AG, Schaan
Status
OK
lj/cp,N
1.000
Page 52
7
Daniel Fisher
dfisher@orie2.com
3/18/2023
Nb [lb]
55,121
7
,:,,s.,
Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
6 Warnings
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 18, 2023 (1)
Page:
Specifier:
E-Mail:
Date:
Page 53
8
Daniel Fisher
dfisher@orie2.com
3/18/2023
The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered -the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The
proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential
concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout
or pryout strength governs.
For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/
The design of Anchor Reinforcement is beyond the scope of PROFIS Engineering. Refer to ACI 318-19, Section 17.5.2.1 (b) for information
about Anchor Reinforcement.
Anchor Reinforcement has been selected as a design option, calculations should be compared with PROFIS Engineering calculations.
Fastening meets the design criteria!
Input data and results must be checked for conformity with the existing conditions and for plausibihty!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilli is a registered Trademark of Hilli AG, Schaan
8
Page 54
1 : i i S • i ______________________ _
Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
7 Installation data
Profile: no profile
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 18, 2023 ( 1)
Hole diameter in the fixture: d1 = 0.687 in.
Plate thickness (input): 0.500 in.
Recommended plate thickness: not calculated
Page:
Specifier:
E-Mail:
Date:
9
Daniel Fisher
dfisher@orie2.com
3/18/2023
Anchor type and diameter: AWS D1 .1 GR. B 5/8
Item number: not available
Maximum installation torque: -
Hole diameter in the base material: -in.
Hole depth in the base material: 12.000 in.
Minimum thickness of the base material: 12.813 in.
Hilti AWS welded headed stud anchor with 12 in embedment, 5/8, Steel galvanized, installation per instruction for use
~~ y
3.750 3.750 -
0 0
C,
N
0 3
.,1 0 0 -C, ..,.
0 0 -C, ... ..,. X
0 ? 1 0 C, ..,.
0 0 0 N
2.250 3.000 2.250
Coordinates Anchor [in.]
Anchor X y c., c., ~ C+y
1 -1.500 -2.000 2.250 5.250
2 1.500 -2.000 5.250 2.250
3 -1 .500 2.000 2.250 5.250
4 1.500 2.000 5.250 2.250
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilli AG. FL-9494 Schaan H1lti is a registered Trademark of Hilti AG. Schaan
9
1 : i i S • 1 ______________________ _
Hilti PROFIS Engineering 3.0.84
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 18, 2023 ( 1)
8 Remarks; Your Cooperation Duties
Page:
Specifier:
E-Mail:
Date:
Page 55
10
Daniel Fisher
dfisher@orie2.com
3/18/2023
Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits. prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each
case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences. such as the recovery of lost or damaged data
or programs, arising from a culpable breach of duty by you.
Input data and results musl be checked for conformity with the existing conditions and for plausibil1ty1
PROFIS Engineering ( c) 2003-2023 Hilti AG. FL-9494 Schaan Hilti is a registered Trademark of Hilti AG. Schaan
10
Orie2 Engineering
Slwcwral Engrneers
9750 Mtfama, Road, Sur.e 310
San D"'90. CA 92126
Fax (85Sf 586--0911
Project No. : 158.033-23
PROJECT: Aviara-lFA-Stairs Garage
Stairs Railing
HSSl½ xl½ x1/g
TOP & BOTTOM 1 1/2 ,f ~v CLR.
I I
r--------I
Ll/2 0 .0 TUBE
I.D u.J -1 Z M r-. H Z _J 0 <( ..-I
_J (._J -1
0.. z N
H
u.J Vl
u.J 0
Vl Z ..._,
II
...J 0 u.J •
I-
3 16
HANDRAIL P
3 16
\_ 3/8"BENT ROD
@ EA . POST
(PICKET)@ 4" MAX .
HSS l ½ xl½ X3/i6
POST@ 4'-0" MAX .
MC12X10 .6
STRINGER
SECTION-AB
Rail Post Weld Loading
M = 553 lb-ft = 6,636 lb-in
V = 186 lbs
Page 56
DATE: 3/16/23
BY : ESY
Stairs Rail Post Weld
WELD GROUP ANALYSIS
Page 57
"WELDGRP.xls" Program
Version 2.1
Using the Elastic Method for up to 24 Total Welds
Job Name: Aviara-lFA-Stairs Gara e
Job Number: 158.033-23
Input Data:
Number of Welds, Nw = !.____4'-----'
Weld Coordinates:
Start End
Weld #1
Weld #2
Weld #3
Weld#4
X1 in.
0.000
0.000
1.500
0.000
Y1 in. X2 in. Y2 in.
0.000 0.000 1.500
0.000
0.000
1.500
·~ ---1.500 0.000
1.500 1.500
1.500 1.500
--------
No. of Load Points = .... I ___ _,
X-Coordinate (in.)=
Y-Coordinate (in.)=
Z-Coordinate (in.)=
Axial Load, Pz (k) =
Point #1
0.750
0.750
0.000 -----0.00
0.00
0.19
6.64
0.00
Load Point Data:
14.0
12.0
_ :§_ 8.0
(/)
~ 6 0
>-
4.0
2.0
Shearload,Px(k)=
Shear Load, Py(k}=
Moment, Mx (in-k) =
Moment, My (in-k) =
Moment, Mz (in-k) = 0.00 L--___ ...___ ___ ....,__ ___ -L-___ _,
1 of 2
Checker: ORO
2.0 4.0 6.0 8.0 10.0 12.0
X -AXIS (in.) ____.
WELD GROUP PLOT
+Y
+Z
1 2
1 =Start
2=End
2
t2_Weld#3 Weld #2
Weld #1
1
1 2
'--origin
+X
NOMENCLATURE
(continued)
3/20/2023 8:21 AM
Results:
Weld Grouo Prooerties· :E Loads @ C G of Weld Group·
Lw =
Xe=
Ye= -Ix=
ly = -J=
6.000
0.750
0.750
2.25
2.25
4.50
Weld #1
Weld #2
Weld #3
Weld#4
in. :E Pz = 0.00 kips
in. I. Px = 0.00 kips
in. r, Py = 0.19 kips
jnA3 I. Mx = 6.64 in-k
inA3 I. My = 0.00 in-k
inA3 I. Mz = 0.00 in-k
Weld Forces k/in.
Fw 1 Fw 2
2.214 2.21 4
2.214 2.21 4
2.214 2.214
2.214 2.214
Reauired E70XX Weld Size:
Fw(max) = 2.214 kips/in.
Fillet (leg) = 0.149 in.
Throat (eff) = 0.105 in.
Size of Weld Required= 0.149"
Size of Weld Provided = 3/16" = 0.1875"
Weld Req / Weld Prov = 0.149 / 0.1875 = 0.80 < 1.0
2 of 2
Page 58
"WELDGRP.xls" Program
Version 2.1
OKAY
3/20/2023 8:21 AM
Section Set
I U)
U)
(.11 m ~ .....
c-5 (.11 X '><= ~ ~ ,...
X ~ ~ ,...
(/)
(/) :r:
Envelope Only Solution
IIIRISA Orie2 Engineering, Inc.
,,. .•• '"'··· ESY 1-------------1
SK-1
Page 59
Section Sets
■ HSS1 .5"x1 .5"x1/8" 0 HSS 1.5"x1 .5"x3/16"
U) ,...
c-5 X ~ ..... X ~ ,...
(/)
(/) :r:
Mar 20, 2023 at 08:15 AM
Aviara Stairs GARAGE railin ...
Loads: BLC 2, L 1
Envelope Only Solution
IIIRISA Orie2 Engineering, Inc.
. . ,. .... ,.. ..,, l...'.E:.::S:..:Y _______
7
Live Load 1
Page 60
0.05 k/ft
SK-2
Mar 20, 2023 at 08:16 AM
Aviara Stairs GARAGE railin ...
Loads: BLC 3, L2
Envelope Only Solution
IIIRISA l...:0::'..'.r.::ie:.::.2..::E::..:n::.:gi.:..:.ne:....:e ___ ri....:ng::.:.,_ln_c_. _1 . . ~ ESY
Live Load 2
Page 61
SK-3
Mar 20, 2023 at 08: 16 AM
Aviara Stairs GARAGE railin ...
Company
Designer
: Orie2 Engineering, Inc.
: ESY IIIRISA Job Number
Model Name :
Model Settinas
Number of Renorted Sections
Number of Internal Sections
Member Area Load Mesh Size <in2)
Consider Shear Deformation
Consider Torsional Waroina
Aooroximate Mesh Size /in)
Transfer Forces Between lntersectinn Wood Walls
Increase Wood Wall Nailina Caoacitv for Wind Loads
Include P-Delta for Walls
Ootimize Masonrv and Wood Walls
Maximum Number of Iterations
Sinnle
Multiole /Ootimum)
Maximum
Global Axis corresnondina to vertical direction
Convert Existina Data
Default Global Plane for z-axis
Plate Local Axis Orientation
Hot Rolled Steel
Stiffness Adiustment
Notional Annex
Connections
Cold Formed Steel
Stiffness Adiustment
Wood
Temoerature
Concrete
Masonrv
Aluminum
Structure Tvne
Stiffness Adiustment
Stainless
Stiffness Adiustment
Comoression Stress Block
Analvze usina Cracked Sections
Leave room for horizontal rebar solices I2*d bar snacina)
List forces which were ianored for desian in the Detail Reoort
Column Min Steel
Column Max Steel
Rebar Material Snee
Warn if beam-column framina arranaement is not understood
Number of Shear Reaions
Reaion 2 & 3 Snacina Increase Increment /in)
Code
Risk Catenorv
Drift Cat
5
100
144
Yes
Yes
24
Yes
Yes
Yes
Yes
3
No
Yes
No
y
Yes
xz
Global
AISC 15th /360-16\: ASD
Yes /Iterative\
None
AISC 14th 1360-10): ASD
AISI S100-16: ASD
Yes /Iterative)
AWC NDS-18 / SDPWS-15 ASD
< 100F
ACI 318-19
TMS 402-16: ASD
AA ADM1-15: ASD
Buildina
Yes /Iterative)
AISC 14th /360-10): ASD
Yes /Iterative)
Rectanaular Stress Block
Yes
Yes
Yes
1
8
ASTM A615
No
4
4
ASCE 7-16
I or II
Other
RISA-3D Version 21 [Aviara Stairs GARAGE railing.r3d]
Page 62
3/20/2023
8:17:18 AM
Checked By:
Page 1
IIIRISA
A Nf:METSGH!:-:K COMPANY
Company
Designer
: Orie2 Engineering, Inc.
: ESY
Job Number
Model Name:
Model Settinas (Continued)
Base Elevation /ft\
Include the weiaht of the structure in base shear calcs
S, {a)
SD, /a)
SDc /a)
T, /sec)
T Z /sec)
TX (sec\
CZ ex
CExo. Z
CEx□. X
RZ
R X
0 n7
OnX c.z c.x oz
oX
Yes
1
1
1
5
0.02
0.02
0.75
0.75
3
3
1
1
4
4
1
1
RISA-3D Version 21 [ Aviara Stairs GARAGE railing.r3d ]
Page 63
3/20/2023
8:17:18AM
Checked By:
Page 2
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name :
Node Coordinates
Label X fft] Y fftl
1 N1 -2612.432742 -4626.405423
2 N2 -2608.891075 -4624.155423
3 N3 -2608.891075 -4620.655423
4 N4 -2605.349409 -4621.905423
5 NS -2605.349409 -4618.405423
6 N6 -2612.432742 -4622.905423
Hot Rolled Steel Properties
Label E fksil G [ksil Nu
1 A992 29000 11154 0.3 0.65
2 A36 Gr.36 29000 11154 0.3 0.65
3 A572 Gr.SO 29000 11154 0.3 0.65
4 A500 Gr.B RND 29000 11154 0.3 0.65
5 A500 Gr.B RECT 29000 11154 0.3 0.65
6 AS00 Gr.C RND 29000 11154 0.3 0.65
7 A500 Gr.C RECT 29000 11154 0.3 0.65
8 A53 Gr.B 29000 11154 0.3 0.65
9 A1085 29000 11154 0.3 0.65
10 A913 Gr.65 29000 111 54 0.3 0.65
Hot Rolled Steel Design Parameters
Label Shape Lenath fftl
1 M1 HSS1 .5"x1 .5"x3/16" 3.5
2 M2 HSS1 .5"x1 .5"x3/16" 3.5
3 M3 HSS1 .5"x1 .5"x3/16" 3.5
4 M4 HSS1 .5"x1 .5"x1/8" 8.392
Hot Rolled Steel Section Sets
Label Shae
1 HSS1 .5"x1.5"x1/8" HSS1.5X1 .5X1/8"
2 HSS1.5"x1.5"x3/16" HSS1 .5X1 .5X3/16"
Design Size and Code Check Parameters
zrm
0
0
0
0
0
0
Density [k/ft3]
0.49
0.49
0.49
0.527
0.527
0.527
0.527
0.49
0.49
0.49
Lcomo too fftl
Lbw
Lbvv
Lbvv
Lbvv
Page 64
3/20/2023
8:17:18AM
Checked By :
Detach From Diaphraam
Yield [ksil Rv Fu [ksil Rt
50 1.1 65 1.1
36 1.5 58 1.2
50 1.1 65 1.1
42 1.4 58 1.3
46 1.4 58 1.3
46 1.4 62 1.3
50 1.4 62 1.3
35 1.6 60 1.2
50 1.4 65 1.3
65 1.1 80 1.1
Channel Conn a fftl Function
N/A N/A Lateral
N/A N/A Lateral
N/A N/A Lateral
N/A N/A Lateral
lzz in• J in•
0.218 0.325
0.289 0.425
Label Max Axial/Bending Chk Max Shear Chk
Typical
Node Loads and Enforced Displacements (BLC 3 : L2/
Node Label L, D, M Direction Ma nitude k*s2/ft, k*s2*ft
N6 L Z
Member Point Loads
No Data to Print. ..
RISA-3D Version 21 [ Aviara Stairs GARAGE railing.r3d ] Page 3
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name:
Member Distributed Loads (BLC 2: L 1)
Page 65
312012023
8:17:18 AM
Checked By :
Member Label Direction Start Ma nitude k/ft, F, ksf, k-ft/ft End Ma nitude k/ft, F, ksf, k-ft/ft Start Location ft, % End Location ft, %
1 M4 Z 0.05 0.05 0 %100
Member Area Loads
No Data to Print...
Basic Load Cases
BLC Description Category Y Gravity Nodal Distributed
Iii D DL -1
L1 LL
L2 LL
Load Combinations
Descri lion Solve P-Delta BLC Factor BLC Factor
D + L1 Yes y DL 2
2 D + L2 Yes y DL 3
Load Combination Design
Service Hot Rolled Cold Formed Wood Concrete Mason Aluminum Stainless Connection
Yes Yes Yes Yes Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes Yes Yes Yes
Envelope Node Reactions
Node Label X k LC y k r c1 LC Z k LC MX k-ft I ll LC MY k-ft r n LC MZ [k-ftl LC
1 N4 max -0.001 2 0.017 2 0.002 2 -0.014 2 -0.026 2 0.001 2
2 min -0.001 1 0.017 1 -0.146 1 -0.447 1 -0.109 1 0.001 1
3 N1 max 0.001 2 0.018 2 -0.087 1 -0.339 1 -0.018 1 -0.001 2
4 min 0.001 1 0.018 1 -0.148 2 -0.415 2 -0.085 2 -0.001 1
5 N2 max 0 2 0.024 2 -0.054 2 -0.159 2 -0.067 2 0 2
6 min 0 1 0.024 1 -0.186 1 -0.553 1 -0.081 1 0 1
7 Totals: max 0 2 0.059 2 -0.2 2
8 min 0 1 0.059 1 -0.42 1
Envelope Beam Deflections
Member Label Soan Location fftl v' finl (n) L'lv' Ratio LC
1 M4 1 max 4.196 0 NC 2
2 1 min 0 0 NC 1
3 2 max 8.392 0 NC 2
4 2 min 4.283 0 NC 1
Envelope Beam Deflection Checks
Beam Deft in Ratio LC Deft in Ratio Deft in Ratio LC
1 M4 0 NC 1 DL+2 0 NC NIA NIA NIA
2 0 NC 1 DL+2 0 NC N/A NIA NIA
RISA-3D Version 21 [Aviara Stairs GARAGE railing.r3d] Page 4
IIIRISA
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name:
Envelope A/SC 15TH (360-16): ASD Member Steel Code Checks
Member Shaoe Code Check Locfft LC Shear Check Locfft DirLC Pnc/om lk
1 M1 HSS1 .5X1 .5X3/16" 0.341 0 2 0.1 11 3.5 z 2 19.015
2 M2 HSS1 .5X1 .5X3/16" 0.454 0 1 0.113 3.5 z 1 19.015
3 M3 HSS 1.5X1 .5X3/16" 0.368 0 1 0.136 3.5 z 1 19.015
4 M4 HSS1 .5X1 .5X1/8" 0.146 8.392 2 0.077 4.196 z 1 3.237
RISA-3D Version 21 [ Aviara Stairs GARAGE railing.r3d ]
Page 66
3/20/2023
8:17:18AM
Checked By :
PnVom lk Mnvv/om lk-ft Mnzz/om lk-ft1 Cb Ean
29.54 1.219 1.219 Q.173 H1-1b
29.54 1.2 19 1.219 1 H1-1b
29.54 1.219 1.219 2.173 H1-1b
20.584 0.887 0.887 1.314 H1-1b
Page 5
Envelope Only Solution
ASD Joint Reactions
Rail Post Weld Loading
M = 553 lb-ft = 6,636 lb-in
V = 186 libs
Reaction and Moment Units are kips and kip-ft (Enveloped)
IIIRISA Orie2 Engineering, Inc.
"'." ESY
Page 67
SK-4
Mar 20, 2023 at 08:17 AM
Aviara Stairs GARAGE raili ...
IIIRISA
ANEMETSCHEK GOMPt\NY
Company : Orie2 Engineering, Inc.
Designer : ESY
Job Number
Model Name : ASD Joint Reactions
Envelope Node Reactions
Node Label X fkl LC Y fkl LC Z fkl LC MX fk-ft
1 N4 max -0.001 2 0.017 2 0.002 2 -0.014
2 min -0.001 1 0.017 1 -0.146 1 -0.447
3 N1 max 0.001 2 0.018 2 -0.087 1 -0.339
4 min 0.001 1 0.018 1 -0.148 2 -0.415
5 N2 max 0 2 0.024 2 -0.054 2 -0.159
6 min 0 1 0.024 1 -0.186 1 -0.553
7 Totals: max 0 2 0.059 2 -0.2 2
8 min 0 1 0.059 1 -0.42 1
RISA-3D Version 21 [ Aviara Stairs GARAGE railing.r3d ]
LC MY fk-ftl LC
2 -0.026 2
1 -0.109 1
1 -0.018 1
2 -0.085 2
2 -0.067 2
1 -0.081 1
Page 68
3/20/2023
8:18:03 AM
Checked By :
MZ [k-ftl LC
0.001 2
0.001 1
-0.001 2
-0.001 1
0 2
0 1
Page 1
Orie2 Engineering Project No. : 158.033-23
St,uctural Engmeers
9750 M .. ma, Road. Surte 310
San 0"'9(). CA 92126
Fax (856) !>86-0911
PROJECT : Aviara-lFA-Stairs Garage
Handrail to (E) CMU Wall
I!. • I!. CMU-·.:-. ,4 WALL V •
Ll/2 0 .0 TUBE
HANDRAIL (TYP)
"<J" I!. ~ -------------
~-__._ ~ ~ ~
WALL BRACKET
l.J z
H
0 z
~ .
0
W/ 3/8"0 X 3" o f-
NOMINAL EMBED j KB-TZ2 EXPANSION Ng§
ANCHOR u
I
I
(ICC ESR-4266) ~
l/)
L = 200 lbs
J J 3
EMBEDMENT
SECTION-AC
M = 200 lbs x 2.25" = 450 lb-in
T,M = 450 lb-in/ 1.5" = 300 lbs
T = 300 lbs
V = 200 lbs
T allow = 590 lbs
V allow = 695 lbs
T /Tallow = 300 / 590 = 0.51 < 1.0 OKAY
V /Vallow = 200 / 695 = 0.29 < 1.0 OKAY
T /Tallow + V / V allow = 0.80 < 1.0 OKAY
0 z
Page 69
DATE: 3/16/23
BY : ESY
Page 70
NOMINAL
ANCHOR
TABLE 3-ALLOWABLE TENSILE LOADS FOR CARBON STEEL AND STAINLESS STEEL KB-TZ2
ANCHORS IN THE FACE OF GROUT-FILLED CONCRETE MASONRY WALLS 1•3·'·5•6
ALLOWABLE SPACING EDGE DISTANCE
NOMINAL TENSILE Critical Minimum Critical Minimum
EMBEDMENT CAPACITY Load Edge Edge Load Spacing, Spacing, DIAMETER AT Sc,AND Cc, Ser S m1n 2 Multiplier Distance, Distance, Multiplier
Cc, Cmtn (INCHES) at S m1n
in. tmml lb (kNl in (mm\ in (mml in (mml in (mm)
¼ 1¾ (44) 145 (0.6) 6 (152) 0.62
17/a (48) 405 (1.8} 6 (152) 3 (76) 0.49
3/a
3 (76) 590 (2.6) 10 (254) 0.58 12 (305)
21/2 (64) 500 (2.2) 8 (203) 0.59
1/2 4 (102)
33/4 (95) 640 (2.8) 13 (330) 0.78 4 (102)
3¼ (83) 890 (4.0) 11 (279) 0.66
51a 5 (127)
41/2 (114) 940 (4.2) 16 (406) 0.61
20 (508)
4 (102) 1,245 (5.5) 13 (330) 0.49
¾ 6 (152)
51/2 (140) 1,385 (6.2) 19 (483) 0.45
For SI: 1 inch = 25.4 mm, 1 lb = 4.45 N.
TABLE 4-ALLOWABLE SHEAR LOADS FOR CARBON STEEL AND STAINLESS STEEL KB-TZ2
ANCHORS IN THE FACE OF GROUT-FILLED CONCRETE MASONRY WALLS 1•3•4•5•6
ALLOWABLE
NOMINAL NOMINAL SHEAR
ANCHOR EMBEDMENT CAPACITY AT
DIAMETER S.,AND Cc,
(INCHES)
in. Imm) lb /kNl ,,. 1¾ (44) 320 (1.4)
17/s (48) 585 (2.6)
31a
3 (76) 695 (3.1)
2½ (64)
'/2 1,045 (4.7)
331. (95)
3¼ (83) 1,735 (7.7)
5/s
41/2 (114) 2050 (9.1)
4 (102) 1,735 (7.7)
¾
5½ (1 40) 2050 (9.1)
For SI: 1 inch= 25.4 mm, 1 lb= 4.45 N.
Footnotes for Table 3 and Table 4:
SPACING EDGE DISTANCE
Critical Minimum Critical Minimum Perpendicular
Spacing, Spacing, Load Edge Edge Load
S er Smtn 2 Multiplier Distance, Distance, Direction
at S mln c., Cmtn Factor at
in lmml in Imm) in Imm) in (mml Cmln
6 (152) 1.00
6 (152) 3 (76)
0.76
10 (254) 12 (305)
8 (203)
4 (102) 0.50
13 (330) 0.73 4 (102)
11 (279) 0.36
5 (127)
16 (406) 0.35
20 (508)
13 (330) 0.36
6 (152)
19 (483) 0.35
at Cm1n
0.87
0.80
0.93
0.94
1.00
0.96
0.96
0.75
0.82
Parallel
Load
Direction
Factor at
Cmtn
1.00
0.99
0.83
0.75
0.85
0.75
0.85
'Values valid for anchors installed in face shells of Type 1, Grade N, lightweight, medium-weight, or normal-weight concrete masonry units
conforming to ASTM C90. The masonry units must be fully grouted with coarse grout conforming to 2021, 2018 and 2015 IBC Section 2103.3,
or 2012 IBC Section 2103.13. Mortar must comply with 2021, 2018 and 2015 IBC Section 2103.2.1, or 2012 IBC Section 2103.9. Masonry
compressive strength must be at least 1,500 psi at the time of anchor installation.
2Loads tabulated are applicable to anchors spaced a critical distance of 4 times the effective embedment. The anchors may be placed at a
minimum spacing, Smon, provided that reductions are applied to the tabulated values.
3Anchors must be installed a minimum of 13/a inches from any vertical mortar joint in accordance with Figure 4.
4Embedment depth must be measured from the outside face of the concrete masonry unit.
5For intermediate edge distances, allowable loads may be determined by linearly interpolating between the allowable loads at the two
tabulated edge distances.
6 The tabulated allowable loads have been calculated based on a safety factor of 5.0.
Orie2 Engineering
Structural Engmeers
9750 Mitamar A:o&d, Sur.e 310
San Diego. CA 92126
Fax (858} 586-0911
3 16
Project No. : 158.033-23
PROJECT: Aviara-lFA-Stairs Garage
Rail Post Embed Plate
L l /2 O.D TUBE
CANE RAIL
EMBED PL3/8X9X9 W/ 4-1/2"0 X 4" HEADED STUDS
3 16
1 'I
I : I
Page 71
DATE: 3/16/23
BY: ESY
HSSl¼ Xll/i Xl/16
POST
EMBED PL3/8X9X9 W/ 4-1/2"0 X 4" HEADED STUDS
SECTION-AD SECTION-AF
REF: 13/GA8.l l
LRFD Load Combination 1.20 + 1.6L
1.6L = 1.6 x 200 lbs = 320 lbs
M = 320 lbs x 42" = 13,440 lb-in
V = 320 lbs
•=iiS•• Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter:
Item number:
Effective embedment depth:
Material:
Evaluation Service Report:
Issued I Valid:
Proof:
Stand-off installation:
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 20, 2023
AWS D1 .1 GR. B 1/2
not available
her = 4.000 in.
Hilti Technical Data
-I -
Design Method ACI 318-19 / CIP
eb = 0.000 in. (no stand-off); t = 0.375 in.
Page:
Specifier:
E-Mail:
Date:
l
Page 72
Daniel Fisher
dfisher@orie2.com
8/10/2023
I
Anchor plateR : Ix x IY x t = 9.000 in. x 9.000 in. x 0.375 in.; (Recommended plate thickness: not calculated)
Profile:
Base material:
Reinforcement:
no profile
cracked concrete, 3000, fc' = 3,000 psi; h = 7.500 in.
tension: not present, shear: not present;
edge reinforcement: none or < No. 4 bar
R -The anchor calculation is based on a rigid anchor plate assumption.
Geometry [in.] & Loading [lb, in.lb]
4
I
z
l y
-~
X
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 H1lti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1:115;.1
Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
1.1 Design results
Case
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 20, 2023
Description
Combination 1
2 Load case/Resulting anchor forces
Anchor reactions [lb]
Tension force: (+ Tension, -Compression)
Anchor Tension force Shear force Shear force x
1 1,084 80 80
2 166 80 80
3 1,084 80 80
4 166 80 80
max. concrete compressive strain: 0.07 [%o]
max. concrete compressive stress: 312 (psi]
resulting tension force in (x/y)=(-1.470/0.000): 2,500 (lb]
resulting compression force in (x/y)=(3.907/-0.000): 2,500 [lb]
Page:
Specifier:
E-Mail:
Date:
Forces [lb] / Moments [in.lb]
N = O; V, = 320; Vy= O;
M, = 0; My= 13,440; Mz = 0;
Shear force y
0
0
0
0
Anchor forces are calculated based on the assumption of a rigid anchor plate.
3 Tension load
Steel Strength*
Pullout Strength*
Concrete Breakout Failure••
Concrete Side-Face Blowout, direction ••
Load Nu• [lb] ------
1,084
1,084
2,500
N/A
• highest loaded anchor ••anchor group (anchors in tension)
Capacity ♦ N0 [lb]
9,555
9,895
5,293
N/A
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Page 73
2
Daniel Fisher
dfisher@orie2.com
8/10/2023
Seismic __ M_a_x. Util. Anchor[%]
no 48
0 3 0 4
®
Tension Compres ion
0 1 0 2
I
Utilization 13N = Nu0/♦ Nn Status
12 OK
11 OK
48 OK
N/A N/A
2
I:115.-i
Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
3.1 Steel Strength
Nsa = Ase.N futa
<j> Nsa ;:,: Nua
Variables
~N[in.2]
0.20
Calculations
N .. [lb]
12,740
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 20, 2023
ACI 318-19 Eq. (17.6.1.2)
ACI 318-19 Table 17.5.2
futa [psi]
65,000
Results
Nsa [lb]
12,740
_____ <!> steel
3.2 Pullout Strength
NpN = ljl c,p NP
NP = 8 Ab,g fc
<I> NpN <': Nua
Variables
0.750 9,555
ACI 318-19 Eq. (17.6.3.1)
ACI 318-19 Eq. (17.6.3.2.2a)
ACI 318-19 Table 17.5.2
ljl .s!c._ ---~'~_2] "-a
1.000 0.59 1.000
Calculations
__ NpJ bL
14,136
Results
N n [lb] ¢> concrete <I> NQ!! [lb]
14,136 0.700 9,895
Nua_llb]
1,084
fc [psi]
3,000
Nua [lb]
1,084
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Page:
Specifier:
E-Mail:
Date:
Page 74
3
Daniel Fisher
dfisher@orie2.com
8/10/2023
3
1 : i i S ~ 1 ______________________ _
Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 20, 2023
Fastening point:
3.3 Concrete Breakout Failure
_ ( ANc) Ncbg -A 'V ec.N 'V ed,N 'V c,N 'V cp,N Nb NcO
<I> N cbg <! Nua
ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
ANc0 = 9 h!r
'V ec.N = ( 1+ ~ e~ ) $ 1.0
3 her
ljJ e<l,N = 0.7 + 0.3 ( ~-S~:) $ 1.0
ljJ cp,N
Variables
her [in.]
4.000
Calculations
s 1.0
ecl,.N~
1.470
kc
24
ANc [in.2] -=---------" ANcO [in.2]
156.25 144.00
Results
<I> concrete
0.700
ec2N [in.]
0.000
"' a
1.000
'V ec1,N
0.803
<l>N~~
5,293
Page:
Specifier:
E-Mail:
Date:
ACI 318-19 Eq. (17.6.2.1b)
ACI 318-19 Table 17.5.2
ACI 318-19 Eq. (17.6.2.1.4)
ACI 318-19 Eq. (17.6.2.3.1)
ACI 318-19 Eq. (17.6.2.4.1b)
ACI 318-19 Eq. (17.6.2.6.1b)
ACI 318-19 Eq. (17.6.2.2.1)
C3_Bl;n [in.] ljJ c,N
2.500 1.000
f0 [psi]
3,000
'V ec2.N ljJ ed,N
1.000 0.825
~.[lb]
2,500
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
ljJ cp,N
1.000
Page 75
4
Daniel Fisher
dfisher@orie2.com
8/10/2023
Nb [lb]
10,516
4
1:11-;;.1
Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
4 Shear load
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 20, 2023
Load V ua [lb)
Steel Strength* 80
Steel failure (with lever arm)* N/A
Pryout Strength** 320
Concrete edge failure in direction y-•• 320
• highest loaded anchor ••anchor group (relevant anchors)
4.1 Steel Strength
V sa = A,,.,v fula
q> V sleel ~ V ua
Variables
ACI 318-19 Eq. (17.7.1 .2a)
ACI 318-19 Table 17.5.2
Ase v [in.~2] ____ ~f"='•..c.[p'-s-"i]
0.20 65,000
Calculations
_y_ .. ~l __
12,740
Results
v •• _ll!1___
12,740
cf> steel ----
0.650
<I> V50 [lb]
8,281
~_J~l
80
Page:
Specifier:
E-Mail:
Date:
Capacity ♦ V" [lb)
8,281
N/A
13,180
3,108
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilli AG, Schaan
Utilization flv = V ua/♦ vn
1
N/A
3
11
Page 76
5
Daniel Fisher
dfisher@orie2.com
8/10/2023
Status
OK
N/A
OK
OK
5
•=iiS•• Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 20, 2023
Fastening point:
4.2 Pryout Strength
V cpg = kcp [ (:::) II' ec.N II' ed,N II' c.N II' cp,N Nb ]
4> v cpg ~ vua
ANc seeACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
ANcO = 9 h!r
11' ec.N = ( 1+ ~ e~ ) ~ 1.0
3 h01
II' ed,N = 0.7 + 0.3 ( ~.•s~:) ~ 1.0
II' cp.N
Variables
-~N
1.000
Calculations
ANc [in.2]
156.25
Results
~ 1.0
h01 [in.]
4.000
Cac [in.]
00
ANc0 (in.2]
144.00
ec1 N [in.]
0.000
kc
24
II' ec1,N
1.000
Page:
Specifier:
E-Mail:
Date:
ACI 318-19 Eq. (17.7.3.1b)
ACI 318-19 Table 17.5.2
ACI 318-19 Eq. (17.6.2.1.4)
ACI 318-19 Eq. (17.6.2.3.1)
ACI 318-19 Eq. (17.6.2.4.1b)
ACI 318-19 Eq. (17.6.2.6.1b}
ACI 318-19 Eq. (17.6.2.2.1)
ec2,N [in.] c.cmin [in.]
0.000 2.500
"-a fc [psi]
1.000 3,000
___ 'l'ec2,N II' ed,N
1.000 0.825
~Jl!>L cj> concrete 4> V cpgJ.1!1_ -Vua_llb]
18,828 0.700 13,180 320
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 H,lti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
II' cp.N
1.000
Page 77
6
Daniel Fisher
dfisher@orie2.com
8/10/2023
Nb (lb]
10,516
6
1 : i i 5 • 1 ______________________ _
Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 20, 2023
4.3 Concrete edge failure in direction y-
Variables
c01 [in.]
2.500
1. [in.]
4.000
Calculations
Ave [in.2]
38.44
Results
c02 [in.]
2.500
II. •
1.000
Avc0 [in.2]
28.12
¢, concrete
0.700
ecv [in.]
0.000
d0 [in.]
0.500
'I' ec.V
1.000
<I> vct,g~]
3,108
Page:
Specifier:
E-Mail:
Date:
ACI 318-19 Eq. (17.7.2.1b)
ACI 318-19 Table 17.5.2
ACI 318-19 Eq. (17.7.2.1.3)
ACI 318-19 Eq. (17.7.2.3.1)
ACI 318-19 Eq. (17.7.2.4.1b)
ACI 318-19 Eq. (17.7.2.6.1)
ACI 318-19 Eq. (17.7.2.2.1a)
'V c,V h0 [in.]
1.000 7.500
fc [psi] \j/ parallel.V
3,000 2.000
\j/ od,V \j/h,V
1.000 1.000
Vu• [lb]
320
5 Combined tension and shear loads, per ACI 318-19 section 17.8
0.472 0.103
c;
5/3
Utilization PN v [%]
31
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Status
OK
v b [lb]
1,624
Page 78
7
Daniel Fisher
dfisher@orie2.com
8/10/2023
7
•=iiS•• Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
6 Warnings
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 20, 2023
Page:
Specifier:
E-Mail:
Date:
Page 79
8
Daniel Fisher
dfisher@orie2.com
811012023
The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered -the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The
proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential
concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout
or pryout strength governs.
For additional information about ACI 318 strength design provisions, please go to https:1/submittals.us.hilti.com/PROFISAnchorDesignGuide/
Fastening meets the design criteria!
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark cl Hilti AG, Schaan
8
,:iis.,
Hilti PROFIS Engineering 3.0.87
www.hilti.com ------
Company: Orie2 Engineering Inc
Address:
Phone I Fax: 18583359452 I
Design: Concrete -Mar 20, 2023
Fastening point:
7 Installation data
Profile: no profile
Hole diameter in the fixture: d1 = 0.562 in.
Plate thickness (input): 0.375 in.
Recommended plate thickness: not calculated
Page:
Specifier:
E-Mail:
Date:
Page 80
9
Daniel Fisher
dfisher@orie2.com
8/10/2023
Anchor type and diameter: AWS 01 .1 GR. B 1/2
Item number: not available
Maximum installation torque: -
Hole diameter in the base material: -in.
Hole depth in the base material: 4.000 in.
Minimum thickness of the base material: 4.813 in.
Hilti AWS welded headed stud anchor with 4 in embedment, 1/2, Steel galvanized, installation per instruction for use
A• y
4.500 4.500
I ._
0 0 lO
N
0 0
0 3
;I lO
-<i-
0 0 ~ C) .. .,,. X
1 ? 0 0 lO -<i-
0 0 lO
N
2.500 4.000 2.500
Coordinates Anchor [in.]
Anchor X y c., c., c.y C+y
1 -2.000 -2.000 2.500 2.500
2 2.000 -2.000 6.500 2.500
3 -2.000 2.000 2.500 6.500
4 2.000 2.000 6.500 6.500
---
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
I:115.Ji
Hilti PROFIS Engineering 3.0.87
www.hilti.com
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Orie2 Engineering Inc
18583359452 I
Concrete -Mar 20, 2023
8 Remarks; Your Cooperation Duties
Page:
Specifier:
E-Mail:
Date:
Page 81
10
Daniel Fisher
dfisher@orie2.com
8/10/2023
Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each
case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data
or programs, arising from a culpable breach of duty by you.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG. FL-9494 Schaan Hilti is a registered Trademark of Hilli AG, Schaan
10