HomeMy WebLinkAbout2760 VICTORIA AVE; ; CB072764; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
12-06-2007 Residential Permit Permit No: CB072764
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No·
Valuation:
Occupancy Group.
# Dwelling Units:
Bedrooms:
Project Title:
2760 VICTORIA AV CBAD
RESDNTL
1674902600
Sub Type:
Lot#:
$48,800.00 Construction Type:
Reference #:
0 Structure Type:
0 Bathrooms:
BESSLER RES-400 SF FAM ROOM
ADDITION
RAD
0
VN
0
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Orig PC#:
Plan Check#:
Applicant: Owner:
TERRY MONTELLO
4715 60TH ST
SAN DIEGO 92115
619 994 5557
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park 1n Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD 113 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot Water Con. Fee
Meter Size
Add'I Pot Water Con. Fee
Reel Water Con. Fee
$380.19
$0.00
$247.12
$0.00
$0.00
$4.88
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0 00
$0.00
$0.00
$0.00
$0.00
BESSLER DAVID&HELEN
2760 VICTORIA AVE
CARLSBAD CA 92010
Meter Size
Add'I Reel. Water Con . Fee
Meter Fee
SDCWA Fee
CFO Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnlieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
TOTAL PERMIT FEES
ISSUED
11/01/2007
LSM
12/06/2007
12/06/2007
Total Fees· $745.19 Total Payments To Date: $247.12 Balance Due:
t fTTl?Il?S
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$69.00
$20.00
$24.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$745.19
$498.07
Inspector: Date: Clearance: _____ _
NOTICE· Please take NOTICE that approval of your project includes the "Imposition" of ees, dedications, reservations, or other exactions hereafter collectively
referred to as 'fees/exactions · You have 90 days from the date this permit was issued lo protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a). and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review. set aside, void, or annul their imposition.
You are hereby FUR rHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes. nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
f eslexacti r as t which the ire .
City of Carlsbad
1635 Faraday Ave., Carlsbad, CA 92008
760-602-2717 / 2718/ 2719
Plan Check No. ~07 ~, ~"-}
Est. Value lf. K ~o
' Fax: 760-602-8558 Plan Ck. Deposit c:9l/f7. ~
Building Permit Application
JOB ADDRES~7
T/PR JECT #
DESCRIPTION OF WORI<: ~
EXISTING USE
CONTACT NAME (If Different Fom Appl/cant/
ADDRESS
ADDRESS
CITY
EMAIL
ARCH/DESIGNER NAME & ADDRESS
STATE ffi
FAX
Date \ '-\ l j 0 ,
SUITE#/SPACE#/UNIT# APN (
# BEDROOMS # BATHROOMS TENANT BUSINESS NAME
mm GW-v1
PATIOS (SF) DECKS (SF)
APPLICANT NAME
STATE
PHONE FAX
EMAIL
STATE UC.#
AIR CONDITIONING
YES □ NO □
ZIP
FIRE SPRINKLERS
YES □ NO □
(lee. 701 I.I Busi nus and Pro~ssions Code: Any City or County which requires a permit to construe~ alter improve. demolish or reP.air any structure prior to its issuance, also requires the applicant for such pennit to file a signed tat,ment that he is rtcensed J)Ur,uant 10 the pro,isions of Ihe Contractors License Law (Chapter 9. commending with Section iOO0 of Division J of th, Business and Prolmions Cod,} or that h, ~ mmpt therefrom, and the bam for the alleged mmption. AJiy violation of Section 703 I.I by any applicant for a permit sub~cu the applicant to a civil penalty of not more than frve hundred dollar, (SSOO}).
Workers' Compensation Declaration: I hereby affirm under penaffy of perjury one of the following declarations:
~
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by. Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
I have and will maintain wor~ti?~y Section 3700 of the Labor Code, for the performryv~~rk ffl~~~ued. My workers' compe~,rtti!tJi:~picY
number are: Insurance Co. ~ J.J..4t...ll\. Polley No. ~~....__..,""JJ_, ___ U,4._"-t-~-:::,1._,-jJ::=f..,._1,-+;---Expiration Date ..,!J..,Ll...._.t"'"l!LLJ=~,-~-,..,,.....,""Q.__..,__
This section need not be completed if the permit is for one hundred dollars ($100) or less.
0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' nsation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation dama s asl1i>tclll1dled for In Section 3706 of the Labor code, interest and attorney's fees.
,/f5 CONTRACTOR SIGNATURE DATE l/-1 -07
I hereby affirm that I am exempt from Contractor·s License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not inlended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply lo an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion. the owner-builder will have the burden of proving that he did not build or improve for the purpose ol sale).
O I, as owner of the property, am exclusively contracting with licensed conlractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply lo an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
0 I am exempt under Section _____ Business and Professions Code for !his reason:
1. I personally plan to provide the major labor and materials for construclion of the proposed property improvement. D Yes D No
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address / phone/ contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate. supervise and provide the major work (include name/ address/ phone/ contractors· license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone/ type of work):
,/f5 PROPERTY OWNER SIGNATURE DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration forrn or risk management and prevention program under Sections 25505. 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? 0 Yes O No
Is lhe applicant or future building occupant required to oblain a permit from the air pollution control district or air quality management district? D Yes D No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D Yes D No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
of the work this permit is issued (Sec. 3097 (i) Civil Code}.
Lender's Address
I certify that I have read the application and state that the above information Is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
!,hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations (1,/er s·o· deep and demolition or construction of structures (1,ler 3 stories in height
EXPIRATION: Every permit issued by the Building Official under • ions of this Code shall expire by fimitation and become nun and void ~ the building or work authorized by such permit is not commenced within
180 days from the date of such permit or~ the uikf uth • by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Unfom1 Building Code).
,/f5 APPLICANT'S SIGNATURE ,,.__,v • ...,..., DATE / / • ,~ (} 7
City of Carlsbad Bldg Inspection Request
For: 04/16/2008
Permit# CB072764
Title: BESSLER RES-400 SF FAM ROOM
Description: ADDITION
Type: RESDNTL Sub Type: RAD
Job Address:
Suite:
Location:
2760 VICTORIA AV
Lot
APPLICANT TERRY MONTELLO
Owner: BESSLER DAVID&HELEN
Remarks:
Total Time:
0
Inspector Assignment: PC ---
Phone: 6199443746
Inspector:
Requested By: ALAN
Entered By: KATHY
CD Description
19 Final Structural
;_pcomment
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
---
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
lns1;2ection Histo[Y
Date Description Act lnsp Comments
04/11/2008 89 Final Combo co PC COMPLETE ELECTRIC AND CONNECT RANGE
02/12/2008 17 Interior Lath/Drywall AP PC
02/12/2008 18 Exterior Lath/Drywall AP PC
02/12/2008 23 Gas/Test/Repairs NR PC NO GAS TEST
02/08/2008 16 Insulation AP PC
02/06/2008 16 Insulation CA PC
02/04/2008 14 Frame/Steel/Bolting/Welding AP PC OK TO INSULATE
02/04/2008 24 Rough/Topout co PC
02/04/2008 34 Rough Electric AP PC
02/04/2008 44 Rough/Ducts/Dampers AP PC
01/31/2008 11 Fig/Foundation/Piers AP PC SEE ENGIN REPORT IN FILE OK TO POUR
01/31/2008 21 Underground/Under Floor AP PC @KIT
01/30/2008 84 Rough Combo CA PC
Inspecti on List
Permit#: CB072764 Type: RESDNTL RAD BESSLER RES-400 SF FAM ROOM
ADDITION
Date Inspection Item Inspector Act Comments
04/16/2008 89 Final Combo PC AP
04/16/2008 89 Final Combo RI
04/11 /2008 89 Final Combo RI
04/11 /2008 89 Final Combo PC co COMPLETE ELECTRIC AND CONNECT
RANGE
02/12/2008 17 Interior Lath/Drywall PC AP
02/12/2008 18 Exterior Lath/Drywall PC AP
02/12/2008 23 Gas/Test/Repairs PC NR NO GAS TEST
02/08/2008 16 Insulation PC AP
02/06/2008 16 Insulation PC CA
02/04/2008 14 Frame/Steel/Bolting/Weldin PC AP OK TO INSULATE
02/04/2008 24 Rough/Topout PC co
02/04/2008 34 Rough Electric PC AP
02/04/2008 44 Rough/Ducts/Dampers PC AP
01/31 /2008 11 Ftg/Foundation/P1ers PC AP SEE ENGIN REPORT IN FILE OK TO
POUR
01/31 /2008 21 Underground/Under Floor PC AP @KIT
01/30/2008 84 Rough Combo PC CA
01 /29/2008 11 Fig/Foundation/Piers PC co PROVIDE ENGR FIX FOR SLAB
01/09/2008 13 Shear Panels/HD's PC PA U/F INT. PANEL
01 /09/2008 14 Frame/Steel/Bolting/Weldin PC WC
12/19/2007 14 Frame/Steel/Bolting/Weldin PC WC
12/19/2007 83 Roof Sheathing/Ext Shear PC AP
12/10/2007 81 Underground Combo PC AP
Wednesday April 16 2008 Page 1 of 1
EsGil Corporation
In Partnersfiip witfi <]overnment for <BuiMin9 Safety
DATE: 11/26/07
JURISDICTION: Carlsbad
PLAN CHECK NO.: 07-2764
PROJECT ADDRESS: 2760 Victoria Ave
SET: II
PROJECT NAME: Room Addition for Bessler Residence
□ APPLICANT ~
,,,-~EVIEWER
□ FILE
1::8:1 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
1::8:1 Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by: ) Fax
Mail Telephone Fax In Person
□ REMARKS:
By: Ray Fuller Enclosures:
Esgil Corporation
0 GA 0 MB 0 EJ 0 PC (P) 11 /19/07
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
-.I
DATE: 11/09/07
JURISDICTION: Carlsbad
PLAN CHECK NO.: 07-2764
EsGil Corporation
In Partnersfiip witfi (}owrnment for <Bui(aing Safety
SET: I
PROJECT ADDRESS: 2760 Victoria Ave
PROJECT NAME: Room Addition for Bessler Residence
<G1:~NT
D PLAN REVIEWER
□ FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information . The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Terry Montello
4715 60th Street San Diego, Ca. 92115
D Esgil Corporation staff did not advise the applicant that the plan check has been completed.
~ Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Te'JY Montello Telephone#: (619) 994-5557
Date contacted)/ /l3t01(by'/.-~) Fax (619) 229-0642
Maily"Telephone
0 REMARKS:
By: Ray Fuller
Fax✓ In Person
Esgil Corporation
0 GA O MB O EJ O PC
Enclosures:
11/05/07
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1 576
Carlsbad 07-2764
11/09/07
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 07-2764 JURISDICTION: Carlsbad
PROJECT ADDRESS: 2760 Victoria Ave
FLOOR AREA:
Addition 400
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 11/01/07
DATE INITIAL PLAN REVIEW
COMPLETED: 11/09/07
FOREWORD (PLEASE READ):
STORIES: 1
HEIGHT: 11 ft per UBC
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 11/05/07
PLAN REVIEWER: Ray Fuller
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments. Clearance from those departments may be req uired prior to
the issuance of a building permit.
Present California law mandates that residential construction comply with the 2001 edition of
the California Building Code (Title 24), which adopts the following model codes: 1997 UBC,
2000 UPC, 2000 UMC and 2002 NEC.
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before th e plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit th e violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad 07-2764
11/09/07
Important Notice Regarding the 2007 CBC
If you are an architect, engineer, designer or contractor that performs work within the
State of California, please be advised that a new building code will take effect on
January 1, 2008. The new building code is based on the 2006 International Building
Code (IBC) and it is significantly different than the Uniform Building Code (UBC).
All plan review applications submitted after December 31, 2007 will be required to
comply with the new code.
The 2007 CBC is currently available for purchase directly from the International Code
Council, at www.iccsafe.org.
1. Please make all corrections on the original tracings, as requested in the correction
list.
• Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1 ). Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92009, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2). Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete
2. Verfiy that the final sets of plans and any new calculations will be stamped and
signed by engineer of record also.
3. Recheck plans for tempered window locations i.e. within 2 ft of interior/exterior
doors. Could not locate for the 2050 SH's next to French Door on sheet 3.
4. Show or note that doors may open to the exterior only if the exterior landing is
not than more than one inch lower than the door threshold. Section 1003.3.1.6
5. Could not locate where exterior lighting was shown to be either high efficacy or
controlled by a combination photocontrol/motion sensor.
I Carlsbad 07-2764
11/09/07
6. Could not locate where famil y room lights were show to be either high efficacy or
be controlled by a manually-on occupancy sensor or dimmer. See also junction
box at dining.
7. Should place Identify number of truss on the roof framing plan .
8. Show or note on plans that all rake walls are to be ballooned framed and could
not determine how upper portion of 4 ft walls will comply with height to width ratio
as would be almost 9 ft?
9. You have submitted a diagram for the island sink that references the IRC. This
has not be adopted. Please incorporate the UPC design into the plans.
10. Complete special inspection form for epoxy bolts.
• Nice Job!
• City to place soils stamp on the plans at issuance .
• To speed up the review process, note on this list (or a copy) where each correction
item has been addressed, i.e., plan sheet, note or detail number, calculation page,
etc.
• Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly describe
them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list? Please
indicate:
Yes □ No □
• The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468,
to perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Ray Fuller at Esgil Corporation. Thank
you.
..
E.x11;N:) A$ Hl5H
A5 ~l6L?! f-J l'\ALL OR e,,,,ener-;.,. .
l...f:A$T' >,s Hc&H .AS
OAAJ}.eal,//lD.N..l.
FlrtlNes·TOEe
OAAJ~.-
~-ll/2"
ISLAND:. SINK VENT DETAIL
'-l----1---~ TO r-e.AR.i=sr
P~~tlON-w.EN 1H<.!!.I
ROOF
NO SCALE
11/13/2~07 06:35 6192290642
Carll,bad 07-2l 64
11/09/07
PERMITS_IN_MOTION PAGE 05/07
C ity of Carlsbad
I :mj G b,el•J4 ·Liii u(J •1 I
BUILDING OEPARThtENT
"K TICE OF REOUIREJ\ilEISI.FOR SPECIAL INSP:ECTTON I Do Not Remove From Plans
Plan Check No.
1
.. 2764
Job Address or L~al Description 2760 Vic toria A.ve
Owner ~~1 E ¢ Address 1,..1 (p D ....I\ 4 °e.t f.\.. Al--/.__
You aro hereby I otified that in addition to the inspection of construct.ion provided by the
Building Dep ent, an approved Registered Special Inspector is required to provido continuous
inspoction during the performance of the phases of construction in.dicated on the reverse side of
this sheet.
The Registered S~ecial I.nspector shall be approved by the City of Carlsbad Building
Department prior ,o the isswmce of the building pexroit. Spee;aI Inspectors having a.
ct11Tent certification from the City of San Diogo, Los Angeles, or lCBO a.tc approved as
Special lnspecto1 for the type of construction for which they are certified.
The inspections hr a Special Inspector do not change the requirements for jnspections by
personnel ofrthe <Xity of Carlsbad building department. Toe inspections by a Special I
~::tor are' in ad~dition to the inspections nonnally required by the County Building
The Special Insp tor is n.ot authorized to inspect and approve any work other than that for which
he/she is specifi ally assigned to inspect. The Spec,al Inspector is not authorized to accept
alternate material~ structural changes, or any requests for plan changes. The Special Inspector is
required to sllbmit written reports to the City of ~dsbad building department of all work that
he/she inspected bd approved. The final inspection approval will not be given until aU Specinl
Inspection tepolti have been received and approved by the City of Carlsbad building department.
Please submit the,namcs oftne inspectors who will perform the special inspections on each of the
items indicated ol the revt!T'Se side of this sheet.
(over)
900'd 9/,9 t 099 898 • cl~O::i 1 10S3 ig :oi l00Z-8T-AON
11/13/2f07 06:35 6192290642 PERMITS_IN_MOTI DN PAGE 06/07
jSPECIAL INSPECTION PROGRAM
Carlsbad 07-1764 11/09/07
,1-,/_,... -A _.... ___ .,.,A A • .If;: ~.fittL,<;.~) cA.
ADDRESS OR LEGAL DESCRIPTION: v I~ ....., 1'-'' --,-y, • ')
I PJ.AN CHEC~ NUMSER: 0] • 'ZJk1: OWNER'S NAME: ~~
1. as the owner. or ks8nt Of the owner (contractors may nm employ the special inspector), certify that I, or
the architect/engineer of record. wlll be responsible for employing the special inspectot(s) as required by
Uniform Building Cbde (UBC) Section 1701 .1 fOf the construction project located at the sit~ nated above.
UBCSeotion108 .. 5. /) /
Signed ~o~
I, es the engi r/archltect of record, certify that I have prepered the following special
Inspection program as required by UBC Section 108.3.5 for the construction project located
at ttw site listed Jbove. ~=~--
Here
Slgnod
1, List of work uil'ing special in$pec;tion:
0 Soils Complial co Prlor to Foundation Inspection D Field Welding D Stroctural Co_1crG«J Over 2500 PSI O High Strength 8oltlng 0 Prestress.d c;pncrete ...8' ExpanslonlEpoxy Anchors
D Structural Ma~onry O Sprayed-On Fireproofing 0 09~igner Specified D Other I -----
2. Name(s) of inclividu~l(s) or flrm(s) responsible for the special inspections listed ~bove:
A. &;,1 9':' ~lr-l? ~-,t4-..ft=:c...T\O~ ~ Ill ~~"'>-N ~-~-~-""lZ-lt:>~
.. .,,,,--:C:cj::.c.,-tt:.~;z,.~(e~•11
3. Duties of the s~ecial inspcc:tors for the work llst9d above: O\ ~v~ Lt,\ ~ •
A. ,=,~ I ~n °~1..L--,~ ,L--t-~,~<lf A~,.,~
eE: e~~ a\ :!?f"o?S:f e:c:fu,L~ -
B. I
C.
Special lnsp~cto~ l h~n check in wlt11 the City and present their credentials for approval ~ beginning
work on the J0b s,tl
900"d 9l9l 09S 898 • dliOD 1 rnsa
Carlsbad 07-2764
11/09/07
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 07-2764
PREPARED BY: Ray Fuller DATE: 11/09/07
BUILDING ADDRESS: 2760 Victoria Ave
BUILDING OCCUPANCY: R3
BUILDING AREA
PORTION (Sq.Ft.)
Addition 400
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb
~ldg. P_ermit Fee by Or~inance _ E
Plan Check Fee by Ordinance -Fl
TYPE OF CONSTRUCTION: VN
Valuation Reg. VALUE
Multiplier Mod.
121 .94
By Ordinance
Type of Review: 0 Complete Review O Structural Only
0 Repetitive Fee __ E] Repeats
Comments:
0 Other
D Hourly .__ ___ ____.I Hour *
Esgil Plan Review Fee
($)
48,776
48,776
$380.191
$247.121
$212.91 I
Sheet 1 of 1
macvalue.doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB O 2/J 2 b l( DATE----+-,/t~i.+-;,//_rlJ __ ( 7
ADDREss,--1J-~7-"-l6""-lv ___ V_~---~..;....._;.Avc: _________ _
l 01-lLCzo--J-0
. Lo .\-J-.l 0
RESIDENTIAL ~ ~ L O 8 res' TENANT IMPROVEMENT
------:ct eJ--/{( .
RESIDENTIAL ADDmON MINOR
~
PLAZA CAMINO REAL .
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER ________________ _
PLANNER ______ _ DATE ____ _;;_ __
DATE_........,/~~4 ""-'~"---W-:.J.---
"" ' ~ " rJ ~ "' D 0
~
>, .D >, .D
.i: ~
~ .c (.)
~ ,:: u
C: .!!l C: .!!l a. a. [;rt]
~ "' 0
>, .D
ij
~ ,:: u
C: "' 0::
□
•• t '
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CBD7-~ i (p'f
Planner Chris Sexton
Address 'J.1 b0 lJ I ci: or i CL. Au
Phone(760)602-4624
APN: l(D1-._.qo-~b
Type of Project & UseOddJ.Tl1
0t'\ Net Project Density: /. Q DU/AC
Zoning:~-I General Plan: fC<lM Facilities Management Zone: __,,.;2_=----
CFD (in/out) #_Date of participation: ____ Remaining net dev acres: __ _
Circle One
(For non-residential development: Type of land used created by this
permit: _____________________ }
Legend: [8] Item Complete@tem Incomplete -Needs your action
Environmental Review Required: YES __ NO V TYPE ___ _
DATE OF COMPLETION: ________ _
Compliance with conditions of approval? If not, state conditions which requi re action.
Conditions of Approval:
Discretionary Action Required: YES __ NOL TYP E ___ _
APPROVAURESO. NO. _______ DATE __ _
PROJECT NO. _________ _
OTH ER RELATED CASES: ___________________ _
Compliance with conditions or approval? If not, state conditions wh ich require action.
Conditions of Approval: ________________________ _
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES __ NOL
CA Coastal Commission Authority? YES NO __
If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103,
San Diego CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Habitat Management Plan
Data Entry Completed? YES __ NO L
If property has Habitat Type iden tified in Table 11 of HMP, complete HMP Permit application and
assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type
impacted/taken, UPDATE!)
lnclusionary Housing Fee required: YES __ NOL
(Effective date of lnclusionary Housing Ordinance -May 21, 1993.)
Data Entry Completed? YES __ NO __
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATE!)
H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06
~□□
□□□
□□□
Site Plan:
Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements,
existing and proposed structures, streets, existing street improvements, rig ht-of-way width,
dimensional setbacks and existing topographical lines (including all side and rear yard slopes).
Provide legal description of property and assessor's parcel number.
Policy 44 -Neighborhood Architectural Design Guidelines
1. Applicability: YES ____ NO v':
2. Project complies YES ___ NO ___ _
Zoning:
1. Setbacks:
Front:
Interior Side:
Street Side:
Rear:
Required ~~· Shown ~<?' Required -~--Shown
Required I~' Shown Lo,
Required T ' Shown / e, t
Top of slope: Required Shown
2. Accessory structure setbacks:
Front: Required ----~.---Shown ----~.---
Interior Side: Required Shown ____ ,::_,_ __
Street Side: Required Shown --~~---
Rear: Required Shown -.JC-------
Structure separation: Required Shown -~-----
3. Lot Coverage:
4. Height:
5. Parking:
Required< 4./ CJ 7o
Required < 60 1
Shown ~ f 't o
Shown .(,, 3 C.., 1
Spaces Required ---'~~'-------Shown _d: ______ _
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required _______ Shown ______ _
Additional Comments ________________________ _
H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06