HomeMy WebLinkAbout2158 TWAIN AVE; ; CBR2024-0501; PermitBuilding Permit Finaled Print Date: 07/07/2025 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: 2158 TWAIN AVE, BLDG-Residential 2081802400 $65,479.04 Residential Permit CARLSBAD, CA 92008-4617 Work Class: Track#: Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check #: Alteration Permit No: Status: (city of Carlsbad CBR2024-0501 Closed -Finaled Applied: 02/28/2024 Issued: 06/12/2024 Finaled Close Out: 07/07/2025 Final Inspection: 06/16/2025 INSPECTOR: Renfro, Chris Description: MCCULLOCH: FIRST FLOOR 1,136 SF INTERIOR REMODEL; NEW EXTERIOR WINDOWS AT KITCHEN Applicant: OFFSET DESIGN FLAVIA GOMES 3509 DEL REY ST, # UNIT 213 SAN DIEGO, CA 92109-5755 FEE BUILDING PLAN CHECK REMODEL-RESIDENTIAL-OTHER Property Owner: MCCULLOCH ANDREW AND MELISSA LIFE TRUST 03-31-22 2158 TWAIN AVE CARLSBAD, CA 92008-4617 SB1473 -GREEN BUILDING STATE STANDARDS FEE STRONG MOTION -RESIDENTIAL (SMIP) Total Fees: $1,329.93 Total Payments To Date: $1,329.93 Balance Due: AMOUNT $519.38 $799.04 $3.00 $8.51 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with t he City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY t o any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov Cbtyof Carlsbad RESIDENTIAL BUILDING PERMIT APP LI CATION B-1 Plan Check CBR2024-0501 Est. Value PC Deposit Date JobAddress2158 TWAIN AVE., CARLSBAD, CA 92008unit: APN:208-180-24-00 ·------ CT /Project #:, _________________ Lot #:TR14340 Year Built: _2_0_0_4 ______ _ BRIEF DESCRIPTION OF WORK:PARTIALL Y INTERIOR REMODEL OF FIRST FLOOR OF EXISTING HOl.J AREA TO BE REMOLED 937 S.F 0 New SF : living SF, ____ Deck SF,. ___ Patio SF, ____ Garage SF __ _ Is this to create an Accessory Dwelling Unit? O Y O N New Fireplace? O YO N, if yes how many? ___ _ ~ Remodel:937 SF of affected area Is the area a conversion or change of use? 0 YE) N □ Pool/Spa: ____ SF Additional Gas or Electrical Features? ___________ _ □Solar: ___ KW, ___ Modules, Mounted:0RoofQGround, Tilt: 0Y0N, RMA:OY ON, Battery:OYO N, Panel Upgrade: Ov ON Electric Meter number: ------------ Other: APPLICANT (PRIMARY CONTACT) Name:Flavia Gomes -Offset Design Address:3509 DEL REY ST Unit 213 City:SAN DIEGO state:CA Zip:92109 Phone:858344 7702 Emau:FLA VIA@OFFSETDESIGNDRAFT .COM DESIGN PROFESSIONAL Name:Flavia Gomes -Offset Design Address:3509 DEL REY ST Unit 213 City:San Diego State:CA Zip:92109 Phone:858344 7702 Email:FLAVIA@OFFSETDESIGNDRAFT.COM PROPERTY OWNER Name:ANDREW & MELISSA MCCULOCH Address:2158 TW Al N AVE., City:CARLSBAD State:CA Zip:92008 Phone: __________________ _ Email: __________________ _ CONTRACTOR OF RECORD Business Name:. ______________ _ Address:, ________________ _ City:, ______ State:, ____ Zip:. _____ _ Phone:. ________________ _ Email: _________________ _ Architect State License: __________ _ CSLB License #: ______ Class:, ______ _ Carlsbad Business License# (Required): ______ _ APPLICANT CERT/FICA TION: I certify that I hove read the application and state that the above information is correct and that the information of the plans is accurate. I agree to comply with all City ordinances and State laws relating ta building construction. NAME (PRINT}: _F_la_vi_a_G_o_m_e_s_____ SIGN,:.,.: __ .,r.U¥v==~~~;:;.___,;;_....;....• DATE: 06/11/2024 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 J" / Email: Bullding@carlsbadca.gov REV. 04122 THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: CBR2024-0501 A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: I herebyaff irm under penal tyof perjury that I am licensed under provisions of Chapter 9 ( commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and ef feet. I alsoaffirm under penalty of perjury one of the fol lowing declarations (CHOOSE ONE): D I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. Policy No. __________________________________________ _ -OR- DI have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: lnsuranceCompany Name:------------------------• Policy No. ____________________________ Expiration Date:-----------------• -OR- D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGENCY. IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name:. _______________________ Lender's Address: ______________________ _ CONTRACTOR CERT/FICA TION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility casements. All proposed modifications and/or additions are dearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions or; lhe property, buildings, slruclures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. NAME (PRINT): _________ SIGNATURE: __________ DATE: ______ _ Note: If the person signing above is an authorized agent for the contract tter of authorization on contractor letterhead. -OR- (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided t hat such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, t he owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). -OR- I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License l aw). -OR- D I am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: AND. D FORM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors./ understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, isavailableuponrequestwhen this application is submitted orat the following Web site: http:I/www.leginfo.ca.gov/calaw.html. OWNER CERT/FICA TION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. NAME (PRINT): An rew ullocti SIGN: uJ.fv\.J l\\'~J-~ DATE: 6111 l2024 Note: If the erson si nin above Is an authorized a ent for the ro e owner include form B-62 si ned b ro ert owner. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Bulldlng@cartsbadca.gov 2 REV. 04/22 ( City of Carlsbad OWNER-BUILDER ACKNOWLEDGEMENT FORM B-61 Development Services Building Division 1635 Faraday Avenue 442-339-2719 www .ca rlsbad ca .gov OWNER-BUILDER ACKNOWLEDGMENT FORM Pursuant to State of California Health and Safety Code Section 19825-19829 To: Property Owner An application for construction permit(s) has been submitted in your name listing you as the owner-builder of the property located at: Site Address 2158 Twain Ave, Carlsbad, CA 92008 The City of Carlsbad ("City") is providing you with this Owner-Builder Acknowledgment and Verification form to inform you of the responsibilities and the possi ble risks associated with typical construction activities issued in your name as the Owner-Builder. The City will not issue a construction permit until you have read and initialed your understanding of each provision in the Property Owner Acknowledgment section below and sign the form. An agent of the owner cannot execute this notice unless you, the property owner, complete the Owner's Authorized Agent form and it is accepted by the City of Carlsbad. INSTRUCTIONS: Please read and initial each statement below to acknowledge your understanding and verification of this information by signature at the bottom of the form. These are very important construction related acknowledgments designed to inform the property owner of his/her obligations related to the requested permit activities. I. AM I understand a frequent practice of unlicensed contractors is to have the property owner obtain an "Owner -Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed contractor and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. II. AM I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed contractor to assume this responsibility. Ill. AM I understand as an "Owner-Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own. IV. AM I understand contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. V. AM I understand if I employ or otherwise engage any persons, other than California licensed contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. REV. 08/20 Owner-Builder Acknowledgement Continued VI. AM I understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disabilit y insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. VII. AM I understand under California Contractors' State License Law, an Owner-Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building contractor. VIII. AM I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) which result from any latent construction defects in the workmanship or materials. IX. AM I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. X. AM I am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the following address: 2158 Twain Ave., Carlsbad, CA 92008 XI. AM I agree that, as the party legally and financially responsible fort his proposed construction activity, I will abide by all applicable laws and requirements that govern Owner-Builders as well as employers. XII. AM I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractor's State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner- Builder and wish to hire contractors, you will be responsible for verifying whether or not those contractors are properly licensed and the status of their workers' compensation coverage. Before a building permit can be issued, this form must be completed, signed by the property owner and returned to the City of Carlsbad Building Division. I declare under penalty af perjury that I have read and understand all of the information provided on this form and that my responses, including my authority to sign this form, is true and correct. I am aware that I have the option to consult with legal counsel prior to signing this form, and I have either (1) consulted with legal counsel prior to signing this form or (2) have waived this right in signing this form without the advice of legal counsel. Andrew McCulloch 06/11/2• Property Owner Name (PRINT) Property Owner Signature Date 2 REV. 08/20 Building Permit Inspection History Finaled {cityof Carlsbad ' PERMIT INSPECTION HISTORY for (CBR2024-0501) Permit Type: BLDG-Residential Application Date: 02/28/2024 Owner: TRUST MCCULLOCH ANDREW AND MELISSA LIFE TRUST 03-31-22 Work Class: Alteration Issue Date: 06/12/2024 Subdivision: CARLSBAD TCT#97-16A KELLY RANCH CORE Status: Closed -Finaled Expiration Date: 04/21 /2025 Address: 2158 TWAIN AVE IVR Number: 55004 CARLSBAD, CA 92008-4617 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Relnspection Inspection Date Start Date Status 08/07/2024 08/07/2024 BLDG-11 257082-2024 Passed Chris Renfro Complete Foundatlon/Ftg/Plers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 10/23/2024 10/23/2024 BLDG-84 Rough 265390-2024 Passed Chris Renfro Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 06/16/2025 06/16/2025 BLDG-Final Inspection 287802-2025 Passed Chris Renfro Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Monday, July 7, 2025 Page 1 of 1 True North COMPLIANCE SERVICES May 21, 2024 City of Carlsbad Community Development Department -Building Division 1635 Faraday Ave. City of Carlsbad -FINAL REVIEW City Penn it No: CBR2024-050 I True North No.: 24-0 I 8-I 84 Carlsbad, CA 92008 Plan Review: Residential Interior Remodel Address: 2158 Twain Ave Applicant Name: Flavia Gomes Applicant Email: flavia@offsetsigndraft.com OCCUPANCY AND BUILDING SUMMARY: Occupancy Groups: Type V-8 (Revise to R-3/U) Occupant Load: N/ A Type of Construction: 58 (Revise to Type V-8) Sprinklers: No Stories: Two Area of Work (sq. ft.): ??? (Provide this information) sq. ft. The plans have been reviewed for coordination with the permit appli cation. Valuation: Confirmed Scope of Work: Confinned Floor Area: Confirmed Attn: Building & Safety Department, True North Compliance Services, Inc. has completed the final review of the following documents for the project referenced above on behalf of the City of Carlsbad: I. 2. Drawings: One (I) copy dated May 7, 2024, by Offset Design+ Drafting. Structural Calculations: Electronic copy dated February 22, 2024, by LoveLace Engineering. The 2022 California Building, Mechanical, Plumbing, and E lectrical Codes (i.e., 2021 IBC, UMC, UPC, and 2020 NEC, as amended by the State of California), 2022 California Green Building Standards Code, 2022 California Existing Building Code, and 2022 California Energy Code, as applicable, were used as the basis of our review. Please note that our review has been completed and we have no further comments True North Compliance Services, Inc. 8369 Vickers Street, Suite 207, Son Diego, CA 92111 T / 562. 733.8030 We have enclosed the above noted documents bearing our review stamps fo r your use. Please call if you have any questi ons or ifwe can be of further assistance. Sincerely, True North Compliance Services Review By: Bashir Habboub -Plan Review Engineer Transmittal Letter April 14, 2024 City of Carlsbad Community Development Department -Building Division 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review: Residential Interior Remodel Address: 21 58 Twain Ave, Carlsbad CA Applicant Name: Flavia Gomes Applicant Email: flavia@offsetdesigndraft.com True North COMPLIANCE SERVICES SECOND REVIEW City Permit No: CBR2024-050 I True North No.: 24-018-184 True North Compliance Services, Inc. has completed the review of the following documents for the project referenced above on behalf of the City of Carlsbad. Our comments can be found on the attached list. I. Drawings: Electronic copy dated April 2, 2024, by Offset Design & Drafting. 2. Structural Calculations: Electronic copy dated February 22, 2024, by Miles T. Lovelace, PE. Attn: Permit Technician, the scope of work on the plans has been reviewed for coordination with the scope of work on the permit application. See below for information if the scope of work on plans differs from the permit application: Valuation: Scope of Work: Floor Area: Confirmed Confirmed Confirmed Our comments follow on the attached list. Please call if you have any questions or if we can be of further assistance. Sincerely, Tru e North Compliance Services Review By: Bashir Habboub -Plan Review Engineer Quality Review By: Alaa Atassi -Plan Review Engineer True North Compliance Services, Inc. 8369 Vickers Street, Suite 207, San Diego, CA 92111 T / 562.733.8030 Residential Interior Remodel 2158 Twain Ave April 14, 2024 City of Carlsbad-SECOND REVIEW City Permit No.: CBR2024-0501 True North No.: 24-018-184 Page2 Plan Review Comments HARD COPY-RESUBMITTAL INSTRUCTIONS: Please do not resubmit plans until all departments have completed their reviews. For status, please contact building@carlsbadca.gov Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). Corrected sets can be submitted as follows: Deliver THREE corrected sets of plans and TWO corrected calculations/reports directly to the City of Carlsbad Building Division, 1635 Faraday Ave., Carlsbad, CA 92008, (442) 339-2719. The city will route the plans to True North, Planning and Land Development Engineering Departments (if applicable) for continued review. Note: Tf this project requires FIRE PREVENTION review, ensure that you follow their specific instructions for resubmittal review. The city will not route plans back to Dennis Grubb & Associates for continued Fire Prevention review. GENERAL INFORMATION: A. The following comments are referred to the 2022 California Building, Mechanical, Plumbing, Electrical Codes, California Green Building Standards Code, and Energy Code (i.e., 2021 IBC, UMC, UPC, and 2020 NEC, as amended by the State of California). B. There may be other comments generated by the Building Division and/or other City departments that will also require your attention and response. This attached list of comments, then, is only a portion of the plan review. Contact the City for other items. C. Respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which details, specification, or calculation shows the required information. Your complete and clear responses will expedite the re-check. D. Where applicable, be sure to include the architect and engineer's stamp and signature on all sheets of the drawings and on the coversheets of specifications and calculations per CBPC 5536.1 and CBPC 6735. This item will be verified prior to plan approval. OCCUPANCY & BUILDING SUMMARY: Occupancy Groups: Occupant Load: Type of Construction: Sprinklers: Stories: Area of Work (sq. ft.): R-3/U NIA VB No Two 937 sq. ft. Residential Interior Remodel 2158 Twain Ave City of Carlsbad-SECOND REVIEW City Permit No.: CBR2024-0501 True North No.: 24-018-184 Page 3 April 14, 2024 NON-STRUCTURAL COMMENTS: T2. Kitchens require exhaust fans to comply with table 150.0-G. Show exhaust fan or a ducted range hood and specify CFM rating on plans. Exhaust fan must be ducted to the exterior of the building. PC2: Please revise the CFM rating to be per CEnC Table 150. 0-G. Since the building area exceeds 1500 sf, the minimum CFM rating shall be 110 CFM if electric range hood and 180 CFM if gas range hood. 11 O CFM if electric 180 CFM if gas STRUCTURAL COMMENTS: S3. Some exterior walls are altered. Please provide calculations for lateral load resisting system (shear walls) or confirm that the existing shear walls are adequate. PC2: Structural calculation indicates the redundancy factor, r, is l. 0. Provide explanation or calculation to justify use of 1.0 instead ofl.3. ASCE 7-16 Section 12.3.4. PC2: Please specify holddowns at other ends of shear walls on sheets S2, S3. PC2: Revise the wind calculations to utilize the 2021 /BC instead of 2018. ~ eNGINEE.Rl"O CLIENT : OFFSET DESIGN STU .. n .. •,n ,,.., ... ,.,,., u•,.•c.•i JOB NO.: J 1nd Ana sis for Low-rise Bulldln , Based INPUT DATA Exposu,e catego,y (B, c or o. ASCe Me :ze.7.3) lmportancefactor(ASCE7-18Talll~ i.,. Bask: wind speed (ASCE 7-18 29 5, 20181 ) V • Topographlcfactor(,',SCE7-1829.8& .8-1) K,. • If you have any questions regarding the above comments, please contact Bashir Habboub via email bashirh@tncservices.com or telephone (562) 733-8030. lEND] Transmittal Letter March 6, 2024 City of Carlsbad Community Development Department -Building Division 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review: Residential Interior Remodel Address: 2158 Twain Ave, Carlsbad CA Applicant Name: Flavia Gomes Applicant Email: flavi a@offsetdesigndraft.com True North COMPLIANCE SERVICES FIRST REVIEW City Permit No: CBR2024-050 l True North No.: 24-018-184 True North Compliance Services, Inc. has completed the review of the following documents for the project referenced above on behalf of the City of Carlsbad. Our comments can be found on the attached list. 1. Drawings: Electronic copy dated February 27, 2024, by Offset Design & Drafting. 2. Structural Calculations: Electronic copy dated February 22, 2024, by Miles T. Lovelace, PE. Attn: Permit Technician, the scope of work on the plans has been reviewed for coordination with the scope of work on the permit application. See below for information if the scope of work on plans differs from the permit application: Valuation: Scope of Work: Floor Area: Confirmed Confirmed Confirmed Ou_r comments follow on the attached list. Please call if you have any questions or if we can be of further assistance. Sincerely, True North Compliance Services Review By: Bashir Habboub -Plan Review Engineer Quality Review By: Alaa Atassi -Plan Review Engineer True North Compliance Services1 Inc. 8369 Vickers Street, Suite 207, San Diego, CA 92111 T / 562.733.8030 Residential Interior Remodel 2158 Twain Ave March 6, 2024 Plan Review Comments HARD COPY -RESUBMITTAL INSTRUCTIONS: City of Carlsbad-FIRST REVIEW City Permit No.: CBR2024-0501 True North No.: 24-018-1 84 Page2 Please do not resubmit plans until all departments have completed their reviews. For status, please contact building@carlsbadca.gov Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). Corrected sets can be submitted as follows: Deliver THREE corrected sets of plans and TWO corrected calculations/reports directly to the City of Carlsbad Building Division, 1635 Faraday Ave., Carlsbad, CA 92008, (442) 339-2719. The city will route the plans to True North, Planning and Land Development Engineering Departments (if applicable) for continued review. Note: If this project requires FIRE PREVENTION review, ensure that you follow their specific instructions for resubmittal review. The city will not route plans back to Dennis Grubb & Associates for continued Fire Prevention review. GENERAL INFORMATION: A. The following comments are referred to the 2022 California Building, Mechanical, Plumbing, Electrical Codes, California Green Building Standards Code, and Energy Code (i.e., 2021 IBC, UMC, UPC, and 2020 NEC, as amended by the State of California). B. There may be other comments generated by the Building Division and/or other City departments that will also require your attention and response. This attached list of comments, then, is only a portion of the plan review. Contact the City for other items. C. Respond in writing to each comment by marking the attached comment list or creating a response letter. Indi cate which details, specification, or calculation shows the required information. Your complete and clear responses will expedite the re-check. D. Where applicable, be sure to include the architect and engineer's stamp and signature on all sheets of the drawings and on the coversheets of specifications and calculations per CBPC 5536. l and CBPC 6735. This item will be verified prior to plan approval. OCCUPANCY & BUILDING SUMMARY: Occupancy Groups: Occupant Load: Type of Construction: Sprinklers: Stories: Area of Work (sq. ft.): Type V-B (Revise to R-3/U) NIA 5B (Revise to Type V-B) No Two ??? (Provide this information) sq. ft. ARCIDTECTURAL COMMENTS: Al. Sheet TS.1: Residential Interior Remodel 2158 Twain Ave City of Carlsbad-FIRST REVIEW City Permit No.: CBR2024-0501 True North No.: 24-018-184 Page3 March 6, 2024 a) Revise the occupancy group to R-3/U -Non-sprinklered instead of Type V-B -Non-sprinklered. I~ R-3/U -Non Sprinklered ! b) Revise the type of construction to VB instead of SB. TYPE OF CONSTRUCTION : TOTAL SITE SO .FT. VB c) Specify the total area of remodel under the scope of work. d) Revise the sheet index as follows: i) Sheets GB 1/GB2/GB3/SP/T 1/ A 7 .1/ A 7 .2 are not part of the plan set. Please remove the sheets from the sheet index ii) Please add the structural sheets (S 1 through SD2) to the sheet index. A2. Sheet Al.3: a) Detail 7-A-10.2 cannot be located for the one-hour wall between the garage and the kitchen. Pleas ensure that ½" minimum gypsum board is applied on the garage side. b) Ensure that the Door between the kitchen and the garage is 20-minute fire-rated and is equipped self-closing and self-latching devices. CRC R302.5. l • 11 1/4" -7" I. c) Since a side hinged door is being replaced with a sliding door, please ensure that the existing door at the foyer complies with the requirements of CRC R3 l l.2 as follows: i) Door shall have a minimum clear width of 32" when measured between the face of the door and the stop, with the door open at 90 degree. A 3 ft wide door provides 32" clear width. ii) Door shall have a minimum clear height of 78", measured from the top of the threshold to the bottom of the stop. d) Provide a landings at exterior door 01 in the direction of travel and not to be more than 7.75" below the top of the threshold. CRC R3 l l .3 .2. Residential Interior Remodel 2158 Twain Ave March 6, 2024 1/2' r l City of Carlsbad-FIRST REVIEW City Permit No.: CBR2024-0501 True North No.: 24-018-184 Page4 e) Revise the plans to provide a clear passageway of not less than 3 feet between counter fronts and appliances or counter fronts and walls in the kitchen. CBC 1208. l il ;f~rij( y f ~ l ::-Co:'"' ow I ,~==='-n -i---..,. ' 1'-. I I --i-EJ I '+-3tt Till I 8' -111/4" 9'-7" A3. Sheet El.I: a) Provide a carbon monoxide alarm outside the movie room in the immediate vicinity. (CRC R315.3) MOVIE ROOM b) Add the following note: The smoke alarms and carbon monoxide alarms shall be interconnected and hardwired per CRC R314.4, R314.5, R315.2.4 and R315.2.5. Residential Interior Remodel 2158 Twain Ave March 6, 2024 MECHANICAL COMMENTS: City of Carlsbad-FIRST REVIEW City Permit No.: CBR2024-0501 True North No.: 24-018-184 Page5 Ml. Add the following note: All exhaust ducts shall terminate at least 3 feet from any opening into the building per CMC 502.2. ELECTRICAL COMMENTS: El. Sheet El. 1: Specify a minimum ofone receptacle outlet in the hallway. CEC 210.52 PLUMBING COMMENTS: Pl. Note on plan the following water-conserving plumbing fixture: Kitchen faucet flush volume shall not exceed 1.8 gallons per minute. CPC 407.2.1.1. GREEN BUILDING COMMENTS: G 1. Climate Action Plan requirements apply to all residential remodels equal to or exceeding $60,000 in valuation. The City of Carlsbad requires that all projects that qualify for CAP compliance will require a completed Climate Action Plan (CAP) Consistency Checklists ( city forms B-50) to be completed by the APPLICANT. https://www.carlsbadca.gov/home/showpublisheddocwnent/6878/638225 I 57825900000 a) For plans submitted to the City the following Climate Action Plan requirements apply, per Carlsbad ordinance: b) The applicant is to fill out the B-50 CAP Consistency Checklist. The scope of work and project valuation will determine which sections of the CAP are required. c) Plan examiners review the B-50 CAP Consistency Checklist for completion. For example: If new residential construction is the scope of work, CAP sections 2A, 3A, and 4A are required to be filled on the B-50 checklist. ENERGY COMPLIANCE COMMENTS: Tl . Specify all proposed switches to be dimmer controlled. CEnergyC 150.0 (K)(2)(F) T2. Kitchens require exhaust fans to comply with table 150.0-G. Show exhaust fan or a ducted range hood and specify CFM rating on plans. Exhaust fan must be ducted to the exterior of the building. STRUCTURAL COMMENTS: S 1. Sheets S2 through S4: Please provide a title for each floor plan as per example below. Residential Interior Remodel 2158 Twain Ave March 6, 2024 ' I I I I ' J I I I I [l,L _________________ r 0FO<lndattonPlan S2. Sheet S5: 1~~~~~~:.~1 --------------------, r- City of Carlsbad-FIRST REVIEW City Permit No.: CBR2024-0501 True North No.: 24-018-184 Page 6 a) Please revise the retrofit pad footing detail to be numbered l as per the plan section callout. l HOTH-~ l 1 (GBITT:R IH?ER POST) !!'~~;~~'!."!!'~l!!~-F-IT_P_A_o_F_o_o_T_I_N_G __ 0 b) Provide 8" minimum clearance from finished grade to bottom of sill plate or specify wood framing members to be preservative-treated. CRC RJl 7.1 & CBC 2304.12.1.2 S3. Some exterior walls are altered. Please provide calculations for lateral load resisting system (shear walls) or confirm that the existing shear walls are adequate. If you have any questions regarding the above comments, please contact Bashir Habboub via email bashirh@tncservices.com or telephone (562) 733-8030. fEND] 0ffsGt design + drafting RESPONSE LETTER -RECORD ID: CRB2O24-05O1 Date: April 2nd, 2024 ATT: Bashir Habboub GENERAL INFORMATION A. NOTED B. NOTED C. NOTED D. NOTED OCCUPANCY & BUILDING SUMMARY 1. PLEASE SEE UPDATED SHEET -TS.1 UNDER PROJECT INFORMATION, AND SCOPE OF WORK err\' Offset Design Draft 3509 Del Rey Street Unit 213, San Diego -California -92109 0ffsGt design + drafting ARCHITECTURAL COMMENTS: A1 SHEETTS.1 A. PLEASE SEE UPDATED SHEET -TS.1 UNDER PARCEL INFORMATION B. PLEASE SEE UPDATED SHEET -TS.1 UNDER PARCEL INFORMATION C. PLEASE SEE UPDATED SHEET -TS.1 UNDER SCOPE OF WORK D. PLEASE SEE UPDATED SHEET -TS.1 UNDER SHEET INDEX A2 SHEET A1 .3: A. PLEASE SEE UPDATED SHEET -A?.1 DETAIL A?.1/1 AND SHEET A1 .3 FOR DETAIL IN PLANS B. PLEASE SEE UPDATED SHEET A1.3 KEYNOTE #13 FOR COMPLIANCE C. PLEASE SEE UPDATED SHEET A1 .3 KEYNOTE #14 FOR COMPLIANCE D. PLEASE SEE UPDATED SHEET A1 .3 FOR LANDING DIMENSIONS E. PLEASE SEE UPDATED SHEET A1.3 FOR KITCHEN PASSAGEWAY DIMENSIONS A3 SHEET E1 .1: A. PLEASE SEE UPDATED SHEET E1 .1 FOR CARBON MONOXIDE ALARM ON PLANS B. PLEASE SEE UPDATED SHEET E1.1 UNDER RESIDENTIAL ENERGY REQUIREMENTS #G MECHANICAL COMMENTS: M1 . PLEASE SEE UPDATED SHEET E1 .1 UNDER RESIDENTIAL VENTILATION REQUIREMENTS -NOTE #5 ELECTRICAL COMMENTS: E1 . PLEASE SEE UPDATED SHEET E1 .1 FOR HALLWAY RECEPTACLE PLUMBING COMMENTS: P1. PLEASE SEE UPDATED SHEET E1 .1 FOR PLUMBING NOTES #1 Offset Design Draft 3509 Del Rey Street Unit 213, San Diego -California -92109 GREEN BUILDING COMMENTS: G1. PLEASE SEE FORM W/ SUBMITTAL ENERGY COMPLIANCE COMMENTS: 0ffsGt design + drafting T1. PLEASE SEE UPDATED SHEET E1 .1 FOR ALL PROPOSED SWITCHES TO BE DIMMER CONTROLED T2. PLEASE SEE UPDATED SHEET E1 .1 FOR LEGEND AND EXAUST FAN IN PLANS STRUCTURAL COMMENTS: S1. PLEASE SEE STRUCTURAL RESPONSE LETTER S2. PLEASE SEE STRUCTURAL RESPONSE LETTER S3. PLEASE SEE STRUCTURAL RESPONSE LETTER Offset Design Draft 3509 Del Rey Street Unit 213, San Diego -California -92109 ,. ,, MCCULLOCH RESIDENCE STRUCTURAL CORRECTIONS PROJECT# CBR2024-501 D CORRECTION # I TITLES ADDED TO PAGES 52, 53, AND 54. 0 CORRECTION # 2 A) PAD FOOTING DETAIL NUMBER ADDED TO SHEET 55 B) 8" MIN. VERTICAL CLEARNACE CALLOUT ADDED TO DETAIL I. PRESSURE TREATED MEMBER INFORMATION IS PROVIDED ON PAGE SI-WOOD NOTES -NOTE 3 0 CORRECTION # 3 SHEAR REINFORCEMENT HAS BEEN ADDED TO LATERAL LINE I ON 22 AND 53. ONLY LATERAL LINE I HAS ALTERED EXTERIOR WALLS. LATERAL LINE A THE OPENING SIZE IS NOT CHANGING. DETAIL 5 55 ADDED FOR FOUNDATION PLAN. DETAIL 6 55 ADDED FOR FLOOR FRAMING. Digitally signed by Miles Lovelace 0ffsGt design + drafting RESPONSE LETTER -RECORD ID: CRB2O24-O5O1 Date: April 16th, 2024 ATT: Bashir Habboub 2nd REVIEW GENERAL INFORMATION A. NOTED B. NOTED C. NOTED D. NOTED OCCUPANCY & BUILDING SUMMARY 1. PLEASE SEE SHEET -TS.1 UNDER PROJECT INFORMATION, AND SCOPE OF WORK Offset Design Draft 3509 Del Rey Street Unit 213, San Diego -California -92109 0tfsGt design + drafting NON-STRUCTURAL COMMENTS : T2 A. PLEASE SEE UPDATED SHEET -E1 .1 UNDER LIGHTING & ELECTRICAL RCP STRUCTURAL COMMENTS: S3 1. PLEASE SEE STRUCTURAL RESPONSE LETTER 2. PLEASE SEE STRUCTURAL RESPONSE LETTER 3. PLEASE SEE STRUCTURAL RESPONSE LETTER Offset Design Draft 3509 Del Rey Street Unit 213, San Diego -California -92109 MCCULLOCH RESIDENCE STRUCTURAL CORRECTIONS PROJECT# CBR2024-501 0 GORREG TION # S3 REDUNDANCY VALUE INCREASED TO 1.3. SHEAR HALLS INCREASED TO NUMBER 3 DUE TO INCREASED LOAD, HOLD-DOHNS STILL OKAY. UPDATED LATERAL PAGES PROVIDED. Q GORREGTION # S3 HOLD-DOHNS ARE NOT NEEDED AT EITHER ENDS OF THE SHEAR HALLS AS THE SHEAR HALLS ARE FORCE TRANSFER SHEAR HALLS USING 'CSl6' STRAPS AT TOP AND BOTTOM OF THE OPENING PER DETAIL 20 SD2. THE THO SHEAR HALLS A CT AS ONE SHEAR HALL ACROSS SMALL OPENINGS. 0 GORREG TION # S3 HIND CALCULATIONS REVISED TO UPDATED 2021 IBC. Digitally signed by Miles Lovelace ~~LOVELACE ENGINEERING STRUCTURAL ENGINEERING SERVICES STRUCTURAL CALCULATIONS DATE: PROJECT: DESICiNER: JOB: FEBRUARY 22, 2024 MCCULLOCH RESIDENCE 2158 TWAIN AVENU E SAN DIEGO, CA 92008 OFFSET DESIGN+ DRAFTING 35098 DEL REY, UNIT 273 SAN DIEGO, CA 92109 ]24075 858.535.9lll I fax 858.535.1989 I www.1--·----· ·~-..u•,, 10509 Vista Sorrento Pkwy, Suite 102 San Diego, CA 92121 ...... l:1te ~ LOVELACE ENGi NEERING JOB J24015 -MCCULLOCH RESIDENCE SHEET NO. TC-I OF ------- CALCULATEDBY _______ C_.K_._ DATE _____ _ STRUCTURAL ENGINEERING SERVICES CHECKEDBY __________ DATE _____ _ 10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121 pllone858.535.91 11 • fax858.535.1989 • www.lDvelaceeng.com SCALE __________________ _ TABLE OF CONTENTS SUBJECT SHEET DESIGN CRITERIA ...................................................................................................................................................... DC-I DESIGN LOADS........................................................................................................................................................... DL-1 VERTICAL ANAL YSIS/DESl<SN .............................................................................................................................. V-1/1 LATERAL ANALYSIS/DESIGN .............................................................................................................................. . FOUNDATIONS /RETAINING WALLS ................................................................................................................... F-1/2 STRUCTURAL NOTES/ SCHEDULES/ DETAILS (WHERE APPLICABLE) ............................................ . TOTAL / II LOVELACE ENGINEERING Joa J24015 -MGGULLOGH -RESIDENCE SHEET NO. DG-1 OF ------ CALCULATEDBY _______ G_.K_._ DATE _____ _ STRUCTURAL ENGINEERING SERVICES CHECKEOBY _________ DATE _____ _ !0509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121 phone 858.535.91 11 • fax 858.535.1989 • www.lovelaceeng.com SCALE _________________ _ DESIGN CRITERIA 60VERNING GODE, GBG 2022 GONGRETE: AGI 318-19 f'c.=2500 psi, NO SPEGIAL INSPECTION 'REQ'D. (U.N.O.) MASONRY: TMS 402-16 I AGI 530-13 MEDIUM WEl6HT, ASTM G90, f'm= 1500 psi, SPEGIAL INSP. 'REQ'D MORTAR: ASTM G210, f'c.=1800 psi, TYPES 6ROUT: ASTM G416, f'c.=2000 psi REINFORGIN6 STEEL, ASTM A615, Fy= 40k.sl FOR # 4 AND SMALLER ASTM A615, Fy= 60k.sl FOR# 5 AND LA-R6ER (U .N.O.) STRUCTURAL STEEL, AISG 360-16, 15TH EDITION ASTM A512, Fy= 50 k.sl (STEEL SHAPES) U.N.O. ASTM A500, eRADE B, Fy= 46k.sl (STRUCTURAL TUBE) ASTM A53, eRADE f?, Fy= 35k.si (STRUCTURAL PIPE) ASTM A36, Fy= 36 k.sl (PLATES) BOLTIN6: A301, SIN6LE PLATE SHEA'R GONN. WELDIN6, WOOD, 6LULAMS, SOIL: A325-N, A490-N Hl6H ST'REN6TH, SIN6LE PLATE SHEA'R GONN. ElOXX SERIES-TYP., E90 SERIES FOR A615 BRADE 60 'REBA'R SHOP WELDIN& TO BE DONE IN AN APPROVED FABRICATOR'S SHOP FIELD WELDIN& TO HAVE CONTINUOUS SPEGIAL INSPECTION. NDS-18 DOU6LAS FIR LA-RGH 24F-V4 FOR SIMPLE SPAN COND ITIONS 24F-V8 FOR CANTILEVER CONDITION ALLOWABLE BEA-RIN6 PRESSURE AG TIVE SOIL PRESSURE -1500 AT-'REST SOIL PRESSURE (-RESTRAINED) = __ _ PASSIVE SOIL PRESSURE = __ _ LATERAL EA'RTHQUAKE PRESSURE =--- GOEFFIGIENT OF FRIG TION = --- psf pc.f pc.f pc.f pc.f ~ EXISTIN6 NATURAL SOIL PER GBG TABLE 18062 SOILS-REPORT BY, PROJEG T NUMBER: DATED: LOVELACE ENGi NEERING Joe -124015 -MCCULLOCH -RESIDENCE SHEET NO. DL-1 OF ------ CALCULATEDBY _______ C_.K_._ DATE _____ _ STRUCTURAL ENGINEERING SERVICES CHECKEDBY _________ DATE _____ _ 10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121 phone 858.535.9111 • fax 858.535.1989 • www.lovelaceeng.com SCALE _________________ _ DESIGN LOADS -ROOF DEAD LOAD: -ROOFIN6 ( COMP, SHINGLES ) ............................. . SHEATHIN6 ................................................ . -RAFTERJCEILIN6 JOISTS OR TRUSSES ...................... . INSULA TION ................................................ . DRYWALL ................................................. . OTHER (ELEC., MECH., MISC.) ............................... . TOTAL DEAD LOAD : LIVE LOA D : (ROOF USE PER IBC TA BLE 1601 .1) TOTAL LOAD: FLOOR DEAD LOAD, FLOOR I N6 ( CARPET 4 PAD ) ............................ . DEX-0-TEX ............................................... . SHEATHIN6 ................................................ . JOISTS .................................................... . DRYHALL / STUCCO ....................................... . OTHER (ELEC., MECH., MISC.) .............................. . TOT AL DEAD LOA D : LIVE LOAD: (RESIDENTIAL USE PER IBG TABLE 1601.1) TOTAL LOAD: EXTERIOR HALL STUDS ..................................................... . DRYWALL ................................................. . INSULA TION ................................................ . EXTERIOR FINISH ( STUCCO ) .............................. . OTHER (MISC.) ............................................ . TOTAL LOAD, INTERIOR WALL STUDS ..................................................... . DRYHALL ................................................. . OTHER (MISC.) TOTAL LOAD: 5.0p sf 1.5 3.5 1.5 2.5 1.0 15.0 psf 20.0p sf 35.0psf 5.0 psf .0 2.0 3.5 2.5 2.0 15.0 psf 40.0psf 55.0psf 1.0psf 2.5 1.5 10.0 1.0 16.0 psf 1.0 psf 5.0 1.0 1.0psf + SOLA-R 3.0 18.0 psf 20.0 p sf 38.0psf DECK/OTHER 2.5 p sf 2.5 2.0 3.5 10.0 4.5 25.0 psf 60.0psf 85.0psf V -1 Joe J24015 -MCCULLOGH RESIDENCE I/"'~ LOVELACE ENGINEERING SHEET NO. __________ Of ______ _ CALCULATEDBY _______ G_._K_._ DATE _____ _ STRUCTURAL ENGINEERING SERVICES CHECKEDBY __________ DATE _____ _ 10509 Vista Sorrento Parkway. Suite 102, San Diego, CA 92121 phone858.535.9111 • faxSSS.535.1989 • www.lovelaceeng.oom SCALE __________________ _ LEVEL: ---'-R-'-"O'---'Oc...cF ___ _ MEMBERS: -=B-=E"-A-'-'-M-'-"S=----!SEE GODE CHECK CALCULATIONS THAT FOLLOHI MARK: REH SPAN= 12.5 FT. X GRID LINE: __ 0 FULL SPAN UNIFORM LOAD H I D= ____ (=l5~=sf~)•~~-'--'-"'a=)-= xx D 1p1FJ L= (40 psf)*(4'/2) W2 D= ___ _ = xx Lr = L f I 1 _1_ l D (plF) L= ___ _ = Lr L W3 D= ______________ _ = D (plF) L= = Lr L = Pl D= __ (,_15'----"'C...::s--'-'f )'-*..,_(1=5_,_'/=2=)(=3_,_'/=2"-)---=-@-'5:::....·=5_' __________ o Maximum 'Reac.tlon (lbsJ L = __ (o.._4_0__,_p_s....:..f)_*(,_15_':....::/2c...:.)..:....:(3'-'c..:./2-=-) ________ = __ __.,,, L D Lr Lr ,-:~_>_D_L_:=_-~=--~=--=~--=~--=~..::-=-=--=--=--=--=--=--=----------___ J.c_'---=--===~: RRm~:I ;;~ I ~gl = I USE, 4xl2 DF. NO. I OR ~ • • MA'RK: RH-I SPAN= 1625 FT. eRID LINE: HI D=------'-'~=..!......_l_:_.:::.._=-----------=---(15 sf )*(16 '/2) D -------"'--L---L 1p1FJ L= (40 sf )*(16 '/2) = Lr W2 D= (18 sf)*(38'/2) = _______ D (plF) L= L (20 sf)*(38'/2) = Lr, W3D= -----===--=-'-'---'---'--'-='--------------D (25 psf )*(l'/2) = (plF) L= ~----------=-,'--L (60 psf)*(l'/2) = Lr 0 FULL SPAN UNIFORM LOAD t W4 D= ___ o Maximum Reac.tlons (lbs) (16 sf)*(8') = (PLF L= ____________________ ..!-'__J_ __ L D Lr L = Lr = P2 D= -----o '-R,= 5810 3080 4300 (lbs) L= -L -Rr= --1.c, 5810 3080 4300 I U_S_E_: ------------------~, -Rm= H l8x40 STEEL HEADER OR MARK: 0 FULL SPAN UNIFORM LOAD RH-2 SPAN= 3 FT. GRID LINE: (15 psf)*(4'/2) H I D =------'-'~=..!........1--'--'-~-----------=---D (plF) L= L (40 sf)*(4'/2) = Lr W2D= D (18 psf)*(4'/2) = (20 sf)*(4'/2) = Lr ,__ __ L = (plF) L = W3D= ------'-'--"-1~~-=-'--------------(16 sf)*(l8') D (p IF) L= ------------=-'----L = Lr t t = Pl D= ______ 0 Maximum 'Reac.tlons (lbs) (lbs) L = ~--L D Lr L f :_u~-!-,:---------------------~"r ~~ ;: I :~ f = __ Lr = 6x6 DF #I OR Project Title: Engineer: Project ID: Project Descr: MCCULLOCH RESIDENCE CK J24075 V-2 Wood Beam Project File: J24075 -VERTICAL.ec6 UC#: KW-06013959, Build:20.23.2.14 DESCRIPTION: RB-1 Lovelace Engineering, Inc. (c) ENERCALC INC 1983-2022 CODE REFERENCES Calculations per NOS 2018, IBC 2021, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method : Allowable Stress Design Load Combination : ASCE 7-16 Wood Species Wood Grade Beam Bracing Douglas Fir-Larch No.1 Completely Unbraced 0(0.2) L(0.5) Fb+ Fb - Fc-Prll Fe-Perp Fv Ft D 0.03 L 0.08 4x12 Span = 12.50 ft 1,000.0 psi 1,000.0 psi 1,500.0 psi 625.0 psi 180.0 psi 675.0 psi E : Modulus of Elasticity Ebend-xx 1,700.0 ksi Eminbend -xx 620.0ksi Density 31.210pcf Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load: D = 0.0150, L = 0.040 ksf, Tributary Width= 2.0 ft, (FLOOR) Point Load : D = 0.20, L = 0.50 k @ 5.50 ft, (FLOOR) DESIGN SUMMARY Design OK Maximum Bending Stress Ratio = 0.674 1 Maximum Shear Stress Ratio = 0.240: 1 Section used for this span 4x12 Section used for this span 4x12 fb: Actual = 720.60psi fv: Actual = 43.16 psi F'b = 1,068.99psi F'v = 180.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 5.520ft Location of maximum on span = 0.000 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span# 1 Maximum Deflection Max Downward Transient Deflection 0.11 2 in Ratio= 1342 >=360 Span: 1 : L Only Max Upward Transient Deflection O in Ratio= 0 <360 n/a Max Downward Total Deflection 0.161 in Ratio = 928>=240 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio= 0<240 n/a Maximum Forces & Stresses for Load Combinations Load Combination lvlax Slress Ral1os lvlomenl 'values Sfiear 'values Segment Length Span# M V CD CM Ct CLx CE Cfu Ci C r M fb F'b V fv F'v DOnly 0.0 0.00 0.0 0.0 Length = 12.50 ft 1 0.228 0.083 0.90 1.00 1.00 0.98 1.100 1.00 1.00 1.00 1.36 220.5 966.0 0.35 13.4 162.0 +D+L 1.00 1.00 0.98 1.100 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 12.50 ft 1 0.674 0.240 1.00 1.00 1.00 0.97 1.100 1.00 1.00 1.00 4.43 720.6 1,069.0 1.13 43.2 180.0 +D+0.750L 1.00 1.00 0.97 1.100 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 12. 50 ft 1 0.451 0.159 1.25 1.00 1.00 0.96 1.100 1.00 1.00 1.00 3.66 595.6 1,320.2 0.94 35.7 225.0 +0.600 1.00 1.00 0.96 1.100 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 12.50 ft 1 0.080 0.028 1.60 1.00 1.00 0.94 1.100 1.00 1.00 1.00 0.81 132.3 1,651.7 0.21 8.1 288.0 Wood Beam UC#: KW-06013959, Build:20.23.2.14 DESCRIPTION: RB-1 Overall Maximum Deflections Load Combination Span +D+L Vertical Reactions Load Combination Max Upward from all Load Cond1t1ons Max Upward from Load Combinations Max Upward from Load Cases DOnly +D+L +D+0.750L +0.60D LOnly Project Title: Engineer: Project ID: Project Descr: Love ace Engineering, Inc. MCCULLOCH RESIDENCE CK J24075 V-3 Project File: J24075 -VERTICAL.ec6 (c) ENERCALC IN 1983-2022 Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span 0.1615 6.159 0.0000 0.000 Support notation : Far left is #1 Values in KIPS Support 1 Support 2 1.133 1.049 1.133 1.049 0.780 0.720 0.353 0.329 1.133 1.049 0.938 0.869 0.212 0.197 0.780 0.720 .... ~ Lovelace Engineering, Inc. liii:::iil 10509 Vista Sorrento Pkwy, Ste. 102 San Diego, CA 92121 Project Title: Engineer: Project ID: Project Descr: MCCULLOCH RESIDENCE CK J24075 V-4 Steel Beam Project File: J24075 -VERTICAL.ec6 LIC#: KW-06013959, Build:20.23.2.14 DESCRIPTION: RH-1 STEEL CODE REFERENCES Calculations per AISC 360-16, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Lovelace Engineering, Inc. (c) ENERCALC IN 1983-2022 Analysis Method Allowable Strength Design Beam Bracing : Completely Unbraced Bending Axis : Major Axis Bending Fy : Steel Yield : E: Modulus : 50.0 ksi 29,000.0 ksi .. 0 0.3~• Lrt0.380) -~------== • 0(0.120) L(0.320) Of.0-1280) 0(0.08750) L(0.210) W18x40 Span• 16.20 n 1 Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width= 8.0 ft, (FLOOR) Uniform Load : D = 0.0180, Lr= 0.020 ksf, Tributary Width= 19.0 ft, (ROOF) Uniform Load : D = 0.0250, L = 0.060 ksf, Tributary Width= 3.50 ft, (DECK) Uniform Load : D = 0.0160 ksf, Tributary W idth= 8.0 ft, (EXTERIOR WALL) DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Ma : Applied Mn / Omega : Allowable Load Combination Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection 0.477: 1 W18x40 45.927 k-ft 96.282 k-ft +D+O. 750Lr+O. ?SOL Span# 1 0.046 in Ratio= 0.000 in Ratio= 0.123 in Ratio= 0.000 in Ratio= Maximum Forces & Stresses for Load Combinations Load Combination l'ii'lax Slress Ral1os Maximum Shear Stress Ratio = Section used for this span Va : Applied Vn/Omega : Allowable Load Combination 4,181 0 1583 0 Location of maximum on span Span # where maximum occurs >=720. <720.0 Span: 1 : L Only >=720. Span: 1 : +D+0.750Lr+0.750L <720.0 Summary of l'ii'lomenl llalues Segment Length Span# M V Mmax+ Mmax -Ma Max Mnx Mnx/Omega Cb Rm DOnly Dsgn. L = 16.20 ft 0.244 0.052 23.54 23.54 160.79 96.28 1.14 1.00 +D+L Dsgn. L = 16.20 ft 0.425 0.090 40.92 40.92 160.79 96.28 1.14 1.00 +D+Lr Dsgn. L = 16.20 ft 0.374 0.079 36.00 36.00 160.79 96.28 1.14 1.00 +O+O. 750Lr+O. ?SOL Osgn. L = 16.20 ft 0.477 0.101 45.93 45.93 160.79 96.28 1.141.00 +D+0.750L Dsgn. L = 16.20 ft 0.380 0.080 36.58 36.58 160.79 96.28 1.14 1.00 +0.600 Dsgn. L = 16.20 ft 0.147 0.031 14.12 14.12 160.79 96.28 1.14 1.00 Design OK 0.101 : 1 W18x40 11.340 k 112.770 k +O+O. 750Lr+O. ?SOL 0.000 ft Span# 1 Summary of Sliear llalues Va Max VnxVnx/Omega 5.81 169.16 112.77 10.10 169.16 112.77 8.89 169.16 112.77 11.34 169.16 112.77 9.03 169.16 112.77 3.49 169.16 112.77 --""'11111 Lovelace Engineering, Inc. :::.:... 10509 Vista Sorrento Pkwy, Ste. 102 San Diego, CA 92121 Steel Beam Project Title: Engineer: Project ID: Project Descr: MCCULLOCH RESIDENCE CK J24075 V-5 Project File: J24075 -VERTICAL.ec6 l UC#: KW-06013959, Build:20.23.2.14 DESCRIPTION: RH-1 STEEL Lovelace Engineering, Inc. (c) ENERCALC INC 1983-2022 Overall Maximum Deflections Load Combination +D+0. 750Lr+0. 750L Vertical Reactions Load Combination Span Max Upward from all Load Cond1t1ons Max Upward from Load Combinations Max Upward from Load Cases D Only +D+L +D+Lr +D+0.750Lr+0.750L +D+0.750L +0.600 Lr Only L Only Max. "-" Dell Location in Span Load Combination 0.1228 8.146 Support notation : Far left is#· Support 1 Support 2 11.340 11 .340 11 .340 11.340 5.812 5.812 5.812 5.812 10.105 10.105 8.890 8.890 11.340 11.340 9.032 9.032 3.487 3.487 3.078 3.078 4.293 4.293 Max. "+" Dell Location in Span 0.0000 Values in KIPS 0.000 -~ Lovelace Engineering, Inc. Project Title: Engineer: MCCULLOCH RESIDENCE CK V-6 ,..... ~ 10509 Vista Sorrento Pkwy, Ste. 102 San Diego, CA 92121 Wood Beam UC#: KW-06013959, Build:20.23.2.14 DESCRIPTION: RH-2 CODE REFERENCES Calculations per NOS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Analysis Method : Allowable Stress Design Load Combination : ASCE 7-16 Wood Species Wood Grade Beam Bracing Douglas Fir-Larch No.2 Completely Unbraced Project ID: J24075 Project Descr: Lovelace Engineering, Inc. ""' Fb + Fb - Fc-Pr11 Fe • Perp Fv Ft Span• 3.0ft 900.0psi 900.0psi 1,350.0 psi 625.0 psi 180.0 psi 575.0 psi Project File: J24075 • VERTICAL.ec6 (c) ENERCALC INC 1983-2022 E : Modulus of Elasticity Ebend-xx 1,600.0ksi Eminbend -xx 580.0ksi Density 31.210pcf Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width= 2.0 ft, (FLOOR) Uniform Load : D = 0.0180, L = 0.020 ksf, Tributary Width= 2.0 ft, (ROOF) Uniform Load : D = 0.0160 ksf, Tributary Width= 18.0 ft, (EXTERIOR WALL) DESIGN SUMMARY Maximum Bending Stress Ratio = 0.26Q 1 Maximum Shear Stress Ratio Section used for this span 6x6 Section used for this span fb: Actual = 233.96psi fv: Actual F'b = 900.00psi F'v Load Combination +D+L Load Combination Location of maximum on span = 1.500ft Location of maximum on span Span # where maximum occurs = Span# 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.002 in Ratio= 19967 >=360 Span: 1 : L Only Max Upward Transient Deflection O in Ratio= 0<360 n/a Max Downward Total Deflection 0.007 in Ratio = 4985 >=240 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0<240 n/a Maximum Forces & Stresses for Load Combinations Load Combination Segment Length V CD CM Cl Clx CE Cfu Ci C r M DOnly Length = 3.0 ft 1 0.217 0.166 0.90 1.00 1.00 1.00 1.000 1.00 1.00 1.00 0.41 175.5 +D+L 1.00 1.00 1.00 1.000 1.00 1.00 1.00 Length = 3.0 ft 1 0.260 0.199 1.00 1.00 1.00 1.00 1.000 1.00 1.00 1.00 0.54 234.0 +D+0.750L 1.00 1.00 1.00 1.000 1.00 1.00 1.00 Length = 3.0 ft 1 0.195 0.149 1.25 1.00 1.00 1.00 1.000 1.00 1.00 1.00 0.51 219.4 +0.60D 1.00 1.00 1.00 1.000 1.00 1.00 1.00 Length = 3.0 ft 1 0.073 0.056 1.60 1.00 1.00 1.00 1.000 1.00 1.00 1.00 0.24 105.3 Design OK = 0.199: 1 6x6 = 35.74 psi = 180.00 psi +D+L = 0.000ft = Span # 1 F'b V fv F'v 0.0 0.00 0.0 0.0 810.0 0.54 26.8 162.0 0.0 0.00 0.0 0.0 900.0 0.72 35.7 180.0 0.0 0.00 0.0 0.0 1,125.0 0.68 33.5 225.0 0.0 0.00 0.0 0.0 1,440.0 0.32 16.1 288.0 Wood Beam LIC#: KW-06013959, Build:20.23.2.14 DESCRIPTION: RH-2 Overall Maximum Deflections Load Combination Span +D+L Vertical Reactions Load Combination Max Upward from all Load Cond1t1ons Max Upward from Load Combinations Max Upward from Load Cases DOnly +D+L +D+0.750L +0.60D L Only Project Title: Engineer: Project ID: Project Descr: Lovelace Engineering, Inc. MCCULLOCH RESIDENCE CK J24075 V -7 Project File: J24075 -VERTICAL.ec6 (c) ENERCALC INC 1983-2022 Max. "-" Dell Location in Span Load Combination Max. "+" Dell Location in Span 0.0072 1.511 0.0000 0.000 Support notation : Far left is #1 Values in KIPS Support 1 Support 2 0.721 0.721 0.721 0.721 0.541 0.541 0.541 0.541 0.721 0.721 0.676 0.676 0.325 0.325 0.180 0.180 LOVELACE ENGi NEERING Jos J24015 -MCCULLOCH -RESIDENCE SHEET NO. f-1 OF ------ CALCULATEDBY _______ C_.K_._ DATE _____ _ STRUCTURAL ENGINEERING SERVICES CHECKEDBY _________ DATE _____ _ 10509 Vista Sorrento Parkway, Suite 102, San Diego. CA 92121 phone858.535.9111 • fax858.535.1989 • www.lovelaceeng.com SCALE _________________ _ FOUNDATION DESIGN ALLOV'IABLE BEA-RING PRESSURE, q= 1500 PSF (PER DESIGN C-RITERIA) CONTINUOUS PERIMETER 4 BEARING v-lALL FOOTINGS, LOCATION: MAX CONTINUOUS FOOTING H1= MAX LOAD = 1815 PLF HIDTH-REQ'D= (H1/q x 12) = lt'>~,1'so_o_K_l.2 = 15 IN I USE: 15 11 HIDE X 18 " DEEP HITH 2 # 4 TOP 4 BOTTOM I LOCATION: H1 = ------------------= PLF IN HIDTH-R.EQ'D= (H1/q x 12) = ____ _ ----= IUSE: "HIDE X II DEEP HITH TOP 4 BOTTOM I LOCATION: -------- H,= ___ _ = PLF HIDTH-R.EQ'D= (H1/q x 12) = __ _ ______ = ___ IN I USE: "HIDE X "DEEP HITH TOP 4 BOTTOM I ISOLATED SPREAD FOOTINGS, ( 2-STORY CONT. FTG. POINT LOADS) MARK, i.E.::lL P= CONT. FTG. CAPACITY (MIDWALL) ------- Areq'd = P/q X 144= 5621f5ao X 144 USE: IZI PER PAD FOOTING SCHEDULE MA-RK,_(F-2) = 5625 LBS = 540 SQ IN P= CONT. FTG. CAPACITY (ENDWALL) = 3281 LBS -~---- Areq'd = P/q x 144= 3.2e>Xsa, x 144 USE: IZI PER PAD FOOTING SCHEDULE MA-RK, (F-3) P= 18" x 18" x 18" DEEP PAD FTG. CAPACITY A"""l'd = P/q x 144= 33•7f500~x~l44~----- USE: IZI PER PAD FOOTING SCHEDULE = 3 15 SQ IN ---- = 3315 LBS = 324 SQ IN H 15 "x36"=540in2 15"x21"=315in2 18"xl8"=324in2 .r:~ LOVELACE Joa J24O15 -MGGULLOGH RESIDENCE ENGi NEERING SHEET NO. F-2 OF ------- GK CALCULATEDBY _________ DATE _____ _ STRUCTURAL ENGINEERING SERVICES 10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121 CHECKE0BY __________ DATE _____ _ phone 858.535.9111 • fax 858.535.1989 • www.lovelaceeng.com SCALE __________________ _ FOUNDATION DESIGN ALLOWABLE BEARING PRESSURE, q= 1500 PSF (PER DESIGN GRITERIN ISOLA TED SPREAD FOOTIN6S, MARK, (F-4) P= 2 4" x 24" SQ. PAD FTG. GAPAGITY = 6000 LBS Areq-d = P/q x 144= 600'¾soo x 144 USE, ~ PER PAD FOOTING SCHEDULE MARK, _(F-5) = 516 SQ IN 24"x24"=516in2 ---- P= 30" x 30" SQ. PAD FTG. GAPAGITY = Gf315 LBS --------- Ar oq' d = P/q x 144= <1311(5_o.ac...cx'-'-'-l44~---------= GfOO SQ IN 3O"x3O"=CfOOln2 USE, {fil PER PAD FOOTING SCHEDULE MA'RK: (F-6) P= 36" x 36" SQ. PAD FTG. GAPA GITY = 13500 LBS --------- A roq 'd = P/q x 144= 1350'a'soo x 144 = 126 Cf SQ IN 36"x36"=12Cf61n2 USE, @J PER PAD FOOTING SCHEDULE MARK, (F-1) P= 42" x 42" SQ. PAD FTG. GAPAGITY = 18315 LBS ------------ Aroq'd = P/q x 144= 18315,:1'soo x 144 = 1164 SQ IN 42"x42"= 1164in2 USE: @J PER PAD FOOTING SCHEDULE HA'RK, (F-8) P= 48" x 48" SQ. PAD FTG. GAPAGITY =24OOOLBS ---------- Aroq'd = P/q x 144= .2400C,,,(5Q_X_l44 _________ =_2_3_O4 SQ IN 48"x48"=23O41n2 USE, [[) PER PAD FOOTING SCHEDULE L-1 ~ MCCULLOCH RESIDENCE CK LOVELACE OFFSET DESIGN STUDIO ENGINEERING 4/2/2024 Sf RUCTU RAL [N0 1N E.ERINC Sf RVtCES J24075 Page: SEISMIC WEIGHT Level 1 FLOOR Typical Plate Ht. (ft.) 8 Element Type Dead Load (psf) Area (sf) Weight Diaphragm ROOF 18 700 12600 Diaphragm FLOOR 15 2100 31500 Diaphragm 0 Dead Load (psf) Length (ft.) Weight Wall EXTERIOR 16 220 28160 Wall INTERIOR 7 150 8400 Wall 0 Dead Load (lbs.) Weight Misc./ Concentrated 0 Total Weight (lbs.) 80660 Seismic Weight (lbs.) 62380 Level 2 ROOF Element Type Dead Load (psf) Diaphragm ROOF 18 Diaphragm Diaphragm Dead Load (psf) Wall EXTERIOR 16 Wall INTERIOR 7 Wall Dead Load (lbs.) Misc./ Concentrated Total 76420 CITY Typical Plate Ht. (ft.) Area (sf) 2250 Length (ft.) 215 150 Seismic Weight CBR2024-0501 2158 TWAIN AVE 8 Weight 40500 0 0 Weight 27520 8400 0 Weight 0 76740 MCCULLOCH: FIRST FLOOR 1,136 SF INTERIOR REMODEL; NEW EXTERIOR WINDOWS AT KITCHEN 2081802400 4/4/2024 CBR2024-0501 ASCE. AMERICAN SOC HY Of CML ENGINl:ERS Seismic Site Soil Class: Results: Ss: S1 Fa : Fv : SMs D -Default (see Section 11.4.3) 0.987 So1 N/A 0.36 T L : 8 1.2 PGA: 0.431 N/A PGAM: 0.517 1.184 FPGA 1.2 SM1 N/A le : 1 Sos 0.79 Cv : 1.294 Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Data Accessed: Thu Feb 22 2024 Date Source: USGS Seismic Design Maps https ://ascehazardtool. org/ Page2 of 3 L-2 Thu Feb 22 2024 .~ LOVELACE ~ FNC--INEl=RING !>TRVCTUAAL (NGIN(.l AING ~(AVICC'S Overall Ht. 24 e- Tc. = C th;; System MCCULLOCH RESIDENCE OFFSET DESIGN STUDIO J24075 SEISMIC BASE SHEAR 11 Period Calculation System Ct All Other Systems 0.02 Ts = 0.589 s Ta = 0.217 s TL= 8 s Base Shear R Omega Cd X 0.75 Wood Shear Walls 6.5 2.5 4.5 1.0 Level 2 1 Site Class: ~ SDS =~ SDl = 0.466 S1 = [ 0.360 V = Cslii' Fx = C..,x V ht. (ft.) 9 15 24 ft. wx (lbs.) 76740 62380 Vertical Distribution hx 24 15 Cs= W= V= k 1 1 1 0.122 139.12 k 16.91 k Total Base Shear wx*hxAk Cvx 1841760 0.66310946 935700 0.33689054 2777460 CK 4/2/2024 Page: per ASCE 7, Fig. 22-14 per ASCE 712.8.1.1 Fx k 11.2 k 5.7 k Ta= Cthnx Ta= 0.217 fV = 1.940 FROM TABLES & LINEAR SM1 = S1 * fV .,. 5D1/ 's = SDs SM1 = 0.698 T5 = 0.589 SD1 = (2/J)SM1 1.ST5 = 0.884051 SD1 = 0.466 :. Per exception 2 of ASCE 7 -16 section 11.4.8 Ta < 1.ST5 so C5 from equation 12.8 -2 can be used and does not need to be factored. INTERPOLATION L -3 A SCE. M'EHICAN SOC HY Of CIVl L"iGINlfllS Address: ASCE Hazards Report Standard: ASCE/SEI 7-16 Risk Category: II Latitude: 33.14181 Longitude: -1 17.298027 L-4 2158 Twain Ave Carlsbad, California 92008 Soil Class: D -Default (see Section 11.4.3) Elevation: 325.216969560486 ft (NAVO 88) Wind Results: Wind Speed 10-year MRI 25-year MRI 50-year MRI 100-year MRI Data Source: Date Accessed: "' y . , .. ,, ., ,.,, .. ,, ... ,, ,,, .. " .. !! •~ H. l 96 Vmph 66 Vmph 72 Vmph 77 Vmph 82 Vmph A,... ... ·'"· ~t~' ,. -· ,.\ ... J ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1-CC.2-4, and Section 26.5.2 Thu Feb 22 2024 1 } Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. https ://ascehazardtool. org/ Page 1 of 3 Thu Feb 22 2024 } PROJECT : MCCULLOCH RESIDENCE CLIENT : OFFSET DESIGN STUDIO "•"' ruu t u c., .. u■,NC. u■v,cu JOB NO. '. J24075 Wind Analysis for Low-rise Building, Based on 2018 IBC/ASCE 7-16 INPUT DATA Exposure category (B. e or o. ASCE 7-16 26.7.3) Importance factor (ASeE 7-16 Table 1.5-2) Basic wind speed (ASeE 7-16 26.5.1 or 2018 IBC) Topographic factor (ASeE 7-16 26.6 & Table 26.8-1) Building height to eave Building height to ridge Building length Building width, including overhangs Overhang sloped width Effective area of components (or Solar Panel area) DESIGN SUMMARY Max horizontal force normal to building length. L, face Max horizontal force normal to building length, B, face Max total horizontal torsional load Max total u ard force ANALYSIS Velocity pressure qh = 0.00256 K, K., K0 K0 V2 C I = w 1.00 V = 100 I<,, = h = e 24 h = r 29.5 L = 75 B = 53 Oh= 0 A= 12 ( 1.12 20.76 psf DATE : 03/29/24 for all Category mph, (160.93 kph) Flat ft, (7.32 m) ft, (8.99 m) ft, (22. 86 m) ft, (16. 15 m) ft, (0.00 m) PAGE DESIGN BY REVIEW BY B ft2, <== Overhang? (Yes or No) No m'J CK 32.10 kips, (143 kN), SD level (LRFD leveQ, Typ. 22.68 kips, (101 kN) 285. 123 ft-kips, (387 kN-m) 63. 90 ki 284 kN where: qh = velocity pressure at mean roof height, h. (Eq. 26.10-1 page 268) K, = velocity pressure exposure coefficient evaluated at height, h, (Tab. 26.10-1. pg 268) Ko = wind directionalijy factor. (Tab. 26.6-1, for building, page 266) 0.95 0.85 26.75 ft L-5 h = mean r..:.o.;..of""h""et"'· "-h"-t -------------~ K. = ground elevation factor. (1.0 per Sec. 26.9, page 268) < 60 ft, [Satisfactory] .__ ___ <..;.M;..;;I.;..;n-=L,'-=B), [Satisfactory) (ASCE 7-16 26.2.1) (ASCE 7-16 26.2.2) Design pressures for MWFRS p = qh [(G c p, )-(G cp1 )] where: p = pressure in appropriate zone. (Eq. 28.3-1, page 311 ). Pmin = 16 psf (ASCE 7-16 28.3.4) G c., = product of gust effect factor and external pressure coefficient, see table below. (Fig. 28.3-1, page 312 & 313) G c., = product of gust effect factor and internal pressure coefficient.(Tab. 26.13-1, Enclosed Building, page 271) = 0.18 or -0.18 a = width of edge strips, Fig 28.3-1, page 312, MAX[ MIN(0.1 B, 0.1 L, 0.4h). MIN(0.04B, 0.04L), 3] = 5.30 ft Net Pressures (psf), Basic Load Cases Net Pressures (psf), Torsional Load Cases Roof angle 8 = 11. 73 Roof angle 8 = 0.00 Roof an Jle 8 = 11.73 Surface Ge., Net Pressure with Ge., Net Pressure with (+GC,,) (-GCp1) (+Ge.,) (-GC.,) Surface Ge., Net Pressure with (+GC.,) (-GC.,) 1 0.46 5.78 13.25 -0.45 -13.08 -5.60 1T 0.46 1.44 3.31 2 -0.69 -18.06 -10.59 -0.69 -18.06 -10.59 2T -0.69 -4.52 -2.65 3 -0.42 -12.44 -4.97 -0.37 -11.42 -3.94 3T -0.42 -3.11 -1.24 4 -0.35 -11.06 -3.59 -0.45 -13.08 -5.60 4T -0.35 -2.76 -0.90 5 0.40 4.57 12.04 Roof an ~le 8 = 0.00 6 -0.29 -9.76 -2.28 1E 0.70 10.69 18.17 -0.48 -13. 70 ~.23 Surface Ge., Net Pressure with (+GC.,) (-GC,,) 2E -1.07 -25.95 -18.48 -1.07 -25.95 -18.48 ST 0.40 1.14 3.01 3E -0.60 -16.23 -8.75 -0.53 -14.74 -7.27 6T -0.29 -2.44 -0.57 4E -0.52 -14.62 -7.14 -0.48 -13.70 ~.23 SE 0.61 8.93 16.40 6E -0.43 -12.66 -5.19 Load Case A (Transverse) Load Case 8 (l ongitudinal) Load Case A (Transverse) Load Case 8 (Longitudinal) Basic Load Cases Torsional Load Coses L-6 Basic Load Case A Transverse Direction Basic Load Case B Longitudinal Direction) Area Pressure !kl wlh Area Pressure /kl with Surface (fr) (+Ge0,) (-Ge•,) Surface (ft') (+Gep,) (-Gep,) 1 1546 8.93 20.48 Povomang = -14.53 psf 2 1743 -31.48 -18.45 2 1743 -31.48 -18.45 (ASeE 7-16 28.3.3) 3 1743 -19.90 -6.87 3 1743 -21.68 -8.66 5 1158 5.29 13.94 4 1546 -17.09 -5.54 6 1158 -11.29 -2.64 1E 254 2.72 4.62 2E 287 -7.44 -5.30 2E 287 -7.44 -5.30 3E 287 -4.23 -2.08 3E 287 -4.66 -2.51 SE 260 2.32 4.27 4E 254 -3.72 -1.82 6E 260 -3.30 -1.35 E Horiz. 29.91 29.91 E Horiz. 22.20 22.20 Vert. -63.90 -34.20 Vert. -51.26 -21.94 Min.wnd Horiz. 32.10 32.10 Min. 'Mnd Horiz. 22.68 22.68 28.4.4 Vert. -63.60 -63.60 28.4.4 Vert. -63.60 -63.60 Torsional Load Case A (Transverse Direction I Torsional Load Case B ILonaltudlnal Dlrectlonl Area Pressure /kl wlh Torsion lft·kl Area Pressure /kl with Torsion /ft-kl Surface (ti') (+Ge•,) (-Ge.,) (+Ge.,) (-Ge•,) Surface (ti') (+Gep,) (-Ge.,) (+Gep.) (-Ge•,) 1 646 3.73 8.55 60 138 2 1743 -31.48 -18.45 -17 -10 2 728 -13.15 -7. 71 -43 -25 3 1743 -19.90 -6.87 11 4 3 728 -9.06 -3.62 30 12 5 449 2.05 5.40 21 56 4 646 -7.14 -2.32 115 37 6 449 -4.38 -1.02 45 11 1E 254 2.72 4.62 88 149 2E 287 -7.44 -5.30 53 38 2E 287 -7.44 -5.30 -49 -35 3E 287 -4.23 -2.08 -30 -15 3E 287 -4.66 -2.51 30 16 SE 260 2.32 4.27 55 102 4E 254 -3.72 -1.82 120 59 6E 260 -3.30 -1.35 79 32 1T 900 1.30 2.98 -24 -56 ST 709 0.81 2.13 -10 -27 2T 1015 -4.58 -2.69 17 10 6T 709 -1.73 -0.40 -22 -5 3T 1015 -3.16 -1.26 -12 -5 Total Horiz. Torsional Load, M, 184.2 184.2 4T 900 -2.49 -0.81 -47 -15 Total Horiz. Torsional Load, M, 285 285 Design pressures for components and cladding rr----,' J<r-2!½;l! ~t1~J.! ~ p = qh[ (G c.> -(G c .. n I r---, I I I I I I I ·-I I I I I I where: p = pressure on component. (Eq. 30.3-1, pg 334) 2 I I I ! I I 2,1 -12, 2,I _ 12, I I I I I~ I I & I Prnn = 16.00 psf (ASeE 7-16 30.2.2) I I I I IN I INI I t...---'-+-3: I I I I G e. = external pressure coefficient. Walls 1.L---;;-_,:' J; Jel-2n--lj; ~!"i-~.i"; ~ see table below. (ASeE 7-16 30.3.2) 0= 11. 73 0 Roof fh 7' Roof 8>7· ElfecUve Zone 1 Zone 1' Zone 2 Zone 2e Zone 2n Zone 2r Area (n') GC. -GC. GC, -Ge, Ge, -GC. GC -GC. GC. -GC, GC, -GC, Comp. 12 0.52 -2.00 --0.52 -2.00 0.52 -2.89 0.52 -2.89 Elfectlve Zone3 Zone3e Zone Jr Zone4 Zone5 Area (112) GC. -GC. GC. -GC. GC. -GC. GC0 -GC. GC0 -GC0 12 --0.52 -2.89 0.52 I -3.46 0.99 -1.09 0.99 I -1.37 Zone 1 Zone 1' Zone 2 Zone 2e Zone 2n Zone 2, Comp. & Cladding Poaltlv• Nefl•tlv• Poalllve N9gat#ve Poeltlv• N-,,.tlve p ...... N.,,Miv• _..,_ --· p ...... N.,,.tlv. Pressure 16.00 -45.25 16.00 -45.25 16.00 -63.66 16.00 -63.66 ( psf) Zone 3 Zone l e Zone 3r Zone4 Zone 5 Poaltlve Neaellt/e Po.ltlve N-aelN• Poeltlv• NH.,lv• Po.Hive Neafflve Po.Hin .... .,,.,. (The Max Pressure 16.00 -63.66 16.00 -75.51 24.21 -26.28 24.21 I -32.22 75.51 psf) L-7 ~ MCCULLOCH RESIDENCE CK LOVELACE OFFSET DESIGN STUDIO 4/2/2024 ENGINEERING Sl"RUCTVRAL [NGIN[.[AIHC, S[.1:-"/ICE!, J24075 Page: LATERAL STORY FORCES Seismic Level Fx (lbs.) Diaphragm Area (sf) ASO Story Load (psf) 0 0.7 2 11212 2250 0.7 3.5 1 5696 2800 0.7 1.4 Wind Direction N-S A-0 Force= 32.1 Pressure= 15.3 psf Level Ht. length area Trib. Ht. ASD diaph. Load 0 Ridge/Parapet 10 75 750 5 0.6 plf 2 9 75 675 14.5 0.6 133 plf 1 9 75 675 9 0.6 83 plf 2100 sf Direction E-W 1-4 Force= 22.68 Pressure= 15.3 psf Level Ht. length area Trlb. Ht. ASO diaph. Load Ridge/Parapet 10 53 530 5 0.6 plf 2 9 53 477 14.5 0.6 133 plf 1 9 53 477 9 0.6 83 plf 1484 sf .~ LOVELACE ~ ENGINEERING STRUCfUR AL E N C IN EEl"-IINC S ERVIC E S MCCULLOCH RESIDENCE OFFSET DESIGN STUDIO J240-75 Level Name Level# Lateral Line ROOF 2 1 Direction E-W CK 4/2/2024 Page: WOOD SHEARWALL ANALYSIS & DESIGN Area 1 2 3 4 SEISMIC LOAD SDS = 0.79 p = 1.0 Story Load Sf 1000 3.5 factor 1.0 Total/2 = Seismic Load psi Load (lbs) u•11 Load Type L None Load (pit) 0 Length L (ft.) 20 Load L (lbs.) 0 1744 lbs. Total/2 = Wind Load ADDITIONAL SEISMIC LOAD ADDITIONAL WIND LOAD Line Segment H H/L Ratio Load Ratio Load E Adj. Load E Load W Adj. Load W Unit Shear E Unit Shear W OTME OTMW Wall Weight Wall UDL Unit. DL Concen. DL CDL loc. DL Moment DLMom. E DLMom. W Net OT E Net OTW Uplift E Add. Uplift E UpliftW Add. Uplift W Tot. Uplift E Tot. UpliftW HD# Load (lbs.) I Offset factor Total Add. Load Total Seismic Load = 1 Max Shear 16 I I I 0 Adjust. Load 0 1744 lbs. SHEAR PLf I USE# OVERTURNING UPLIFT • -No HD required, by inspection •• -See Perforated/ Force-Transfer Shearwall calculatiqn Line Load (lbs.) Total Wind Load = 1 Shear Wall WIND LOAD Load Type R Load (pit) Length R (ft.) Load R (lbs.) 0 lbs. Offset factor Adjust. Load Total Add. Load 0 0 lbs. None 0 0 0 Total Shear Length (ft.) 0 lbs. lbs. lbs. lbs. pit pit Capacity= 260 pit #-ft. #-ft. psi plf pit lbs. ft. #-ft. #-ft. #-ft. #-ft. #-ft. lbs. lbs. lbs. lbs. lbs. lbs. L-8 lvll.ttlo CIC 2306.J ~~ LOVELACE ~ ENGINEERING STRUCTURA L EN C 1N EEHINC SERVICES MCCULLOCH RESIDENCE OFFSET DESIGN STUDIO J24075 Level Name Level # Lateral Line floor 1 1 Direction E-W CK 4/2/2024 Page: WOOD SHEARWALL ANALYSIS & DESIGN Area 1 2 3 4 SEISMIC LOAD sos = 0.79 p = LO Story Load SF 1150 145 1.4 Factor 1.0 1.0 Total/2 = Seismic Load psf Load (lbs) 1638 Load Type L 1 -4 206 Load (plf) 83 0 Length L (ft.) 20 0 Load L (lbs.) 1651 922 lbs. Total/2 = Wind Load ADDITIONAL SEISMIC LOAD ADDITIONAL WIND LOAD Line Load (lbs.) Ofuet Factor Adjust. Load Line Load (lbs.) 1 1744 1.00 1744 1 Total Add. Load 1744 Total Seismic Load = 2666 lbs. Total Wind Load = SHEAR Segment 1 2 L 6.5 I 4 H 9 9 H/L Ratio 1.4 2.3 Load Ratio 0.62 0.38 Load E 1651 1016 Adj. Load E 1143 Load W 511 314 Adj. Load W 365 225 Unit Shear E 254 286 Unit Shear W 56 56 Max Shear 286 PLF I USE# 2 Shear Wall OVERTURNING OTM E 14855 9141 OTM W 4598 2830 Wall Weight 16 16 WallUDL 144 144 Unif. DL Concen. DL COL loc. DL Moment 3042 I 1152 DLMom. E 1489 564 DLMom. W 1825 691 Net OTE 13366 8577 Net OTW 2773 2138 UPLIFT Uplift E 2056 2144 Add. Uplift E UpliftW 427 535 Add. Uplift W Tot. Uplift E 2056 2144 Tot. Uplift W 427 535 HO# .. .. . -No HD required, by inspection •• -See Perforated / Force-Transfer Shearwall calculation WIND LOAD Load Type R Load (plf) Length R (ft.) Load R (lbs.) 825 lbs. Ofuet Factor Adjust. Load 1.0 Total Add. Load 0 825 lbs. 1-4 83 0 0 Total Shear Length (ft.) 11 lbs. lbs. lbs. lbs. plf plf Capacity = 350 plf #-ft. #-ft. psf plf plf lbs. ft. #-ft. #-ft. #-ft. #-ft. #-ft. lbs. lbs. lbs. lbs. lbs. lbs. L -9 •v~•Ho CIC llOI.J I~ LOVELACE ~ ENGINEERING srRVCTUllAL EN Glr-fEERING ~LllVI CES Shear E 2666 Segment Adj. Shear E 1143 Adjust. Shear E 2666 Shear w 82S Adjust. Shear W S89 ll (ft.) 6.S H above 2 ft. H opening 4 ft. H below 3 ft. Total Height 9 ft. LI w v,...., l I I I I • CptfJ I I I • IT,...., OVERTURNING OTM E 23996 lb.-ft. OTMW 7428 lb.-ft. Wall Weight 32 psf Wall UOL 288 plf Uniform Ol 10 plf Ol Moment 27155 lb.-ft. OLMoment E 13290 lb.-ft. OLMoment W 16293 lb.-ft. Net OTE 10706 lb.-ft. Net OTW -8866 lb.-ft. MCCULLOCH RESIDENCE OFFSET DESIGN STUDIO J24075 Level Name Level# Lateral Une FLOOR 1 1 Direction E-W FORCE TRANSFER SHEAR WALL SHEAR Net shear to segments, non-adjusted for segment ratio Segment-adjusted shear per NOS 4.3.4 adjusted for overall H/l ratio of Force-Transfer Shear Wall Net shear to segments, non-adjusted per CBC 2306.3 Adjusted shear value per CBC 2306.3 Total Perforated Overall W(ft.) l2 (ft.) length (ft.) Length (ft.) H/l Ratio 3.0 4.0 14 11 0.7 E w Maximum V 197 44 plf Strap Force 367 Shear 254 Strap Force 1 367 81 lbs. Use CS16 v' 254 56 plf Use# 1 Strap Force 2 226 50 lbs. v<'bo.) . L2 u_[JLll _J_l_flJLJ_u l I I I I l_ .., <io(rJ :i! v,-.. IIDCD [JI ]JII j -:-;;i;;--~1V . --· ~ v<'lo.J ~rn Ii II ]ffiS j ,- ---~;;,----v•:pt,J UPLIFT Uplift E 793 lbs. Add. Uplift E lbs. Uplift W -657 lbs. Add. Uplift W lbs. Tot. Uplift E 793 lbs. Tot. UpliftW ~57 lbs. HO# 1 L -10 CK 4/2/2024 Page: lbs. plf strap Shear Wall y • VI\. V' • Vlf'LltL.11 "' • V • Cv-UI -<V-UI .-i • .v • ""1.l<M&> • <v·"-11 ~ L OVELACE MCCULLOCH RESIDENCE Level Name floor CK ENGINEERING OFFSET DESIGN STUDIO Level# 1 Direction 4/18/2024 ~HH,<. 1.,,HAL I.NC .. 'I !:. L H\ "4(; ~ (.J,;y 1c·t ~ J24075 Lateral Line 1 E-W Page: ! WOOD SHEARWALL ANALYSIS & DESIGN 11 SEISMIC LOAD SDS = 0.79 p = 1.3 Story Load 1.4 psf Area SF Factor Load (lbs) WIND LOAD 1 1150 1.0 1638 Load Type L 1-4 Load Type R 1·4 2 145 1.0 206 Load (plf) 83 Load (plf) 83 3 0 Length L (ft.) 20 Length R (ft.) 0 4 0 Load L (lbs.) 1651 Load R (lbs.) 0 Total/2 = Seismic Load 922 lbs. Total/2 = Wind Load 825 lbs. ADDITIONAL SEISMIC LOAD ADDITIONAL WIND LOAD Line Load (lbs.) Offset Factor Adjust. Load Line Load (lbs.) Offset Factor Adjust. Load 1 1744 1.00 1744 1 1.0 Total Add. Load 1744 Total Add. Load 0 Total Seismic Load = 3466 lbs. Total Wind Load = 825 lbs. SHEAR Segment 1 2 ... Total Shear Length (ft.) L 6.5 4 11 H 9 9 H/L Ratio 1.4 2.3 Load Ratio 0.62 0.38 Load E 2146 1320 lbs. Adj. Load E 1485 lbs. 8y'la110 Load W 511 314 lbs. Adj. Load W 365 225 lbs. CIIC 2306 l Unit Shear E 330 371 pit Unit Shear W 56 56 pit Max Shear 371 PLF I USE# 3 Shear Wall I Capacity= 490 plf OVERTURNING OTME 19311 11884 #-ft. OTMW 4598 2830 #-ft. Wall Weight 16 16 psf Wall UDL 144 144 plf Unit. DL pit Concen. DL lbs. CDL lac. ft. DL Moment 3042 1152 #-ft. DL Mom. E 1489 564 #·ft. DL Mom.W 182S 691 #-ft. Net OT E 17822 11320 #-ft. Net OTW 2773 2138 #-ft. UPLIFT Uplift E 2742 2830 lbs. Add. Uplift E lbs. UpliftW 427 535 lbs. Add. Uplift W lbs. Tot. Uplift E 2742 2830 lbs. Tot. Uplift W 427 535 lbs. HD# .. .. • -No HD required, by inspection "', ____ " -See Perforatl!d / Force-Transfer Shearwall calculation "' I ,, j ~ LOVELACE MCCULLOCH RESIDENCE Level Name FLOOR CK ENGINEERING OFFSET DESIGN STUDIO Level# 1 Direction 4/18/2024 ::,l~V<;. l l,U\L !.H <.. 'tl::l'-l.l'lV !:,l;RVlt;~:, J24075 Lateral Line 1 E-W Page: FORCE TRANSFER SHEAR WALL 11 SHEAR Shear E 3466 Net shear to segments, non-adjusted for segment ratio Segment AdJ. Shear E 1485 Segment-adjusted shear per NOS 4.3.4 Adjust. Shear E 3466 adjusted for overall H/L ratio of Force-Transfer Shear Wall ShearW 825 Net shear to segments, non-adjusted per CBC 2306.3 Adjust. Shear W 589 Adjusted shear value per CBC 2306.3 Total Perforated Overall Ll (ft.) w (ft.) L2 (ft.) Length (ft.) Length (ft.) H/L Ratio 6.5 3.0 4.0 14 11 0.7 H above 2 ft. E w Maximum V 257 44 plf Strap Force 477 lbs. H opening 4 ft. Shear 330 plf Strap Force 1 477 81 lbs. H below 3 ft. Use CS16 strap I v' 330 56 plf Use# 2 Shear Wall Total Height 9 ft. Strap Force 2 293 50 lbs. L.1 W L.2 U_lJLll_J_I_ITJLJ_u v ■ VIL ,,,...., [Ji ]JI iiow V • VA'L\<C..JJ ---..... <plr> ,,,...., II II ~ • -V • l,l(Ll4.I.> • (v'"L.l') OVERTURNING UPLIFT OTME 31195 lb.-ft. Uplift E 1326 lbs. OTMW 7428 lb.-ft. Add. Uplift E lbs. Wall Weight 32 psf UpliftW -657 lbs. Wall UDL 288 pit Add. Uplift W lbs. Uniform DL 10 plf Tot. Uplift E 1326 lbs. DL Moment 27155 lb.-ft. Tot. Uplift W -657 lbs. DL Moment E 13290 lb.-ft. HD# 1 DL MomentW 16293 lb.-ft. Net OT E 17905 lb.-ft. Net OTW -8866 lb.-ft. ( City of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue 442-339-2719 www.carlsbadca.gov This checklist is intended to help building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their project. This completed checklist (B-50) and summary (B-55) must be included with the building permit application. The Carlsbad Municipal Code (CMC) can be referenced during completion of this document. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool The B-50 checklist was originally developed several years ago to support implementation of the CAP. Recent updates to the California Building Standards Code have imposed newer performance standards on building permit applications. Therefore, the applicant is advised to review all applicable code sections and apply the maximum performance standard, which may exceed the CAP consistency checklist requirements Consultation with a certified Energy Consultant is encouraged to assist in filling out this document. Appropriate certification includes, but is not limited to: Licensed, practicing Architect, Engineer, or Contractor familiar with Energy compliance, IECC/HERS Compliance Specialist, ICC GB Energy Code Specialist, RESNET HERS rater certified, certified ICC Residential Energy Inspector/Plans Examiner, ICC Commercial Energy Inspector and/or Plans Examiner, ICC CALgreen Inspector/Plans Examiner, or Green Building Residential Plan Examiner. If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, check N/A and provide an explanation or code section describing the exception. The project plans must show all details as stated in the applicable Carlsbad Municipal Code (CMC) and/or Energy Code and Green Code sections. Appllcatlon Information Project Name/Building Permit No.: McCulloch Residence BP No.: CB R2024-0 Date: 03/27 /24 PropertyAddress/APN: 2158 Twain ave., Carlsbad.CA , 92008 / 208-180-24-00 Applicant Name/Co.: Flavia Gomes Applicant Address: 3509 Del Rey St. , unit 23, San Diego, CA 92109 Contact Phone: 858-344-7702 Contact Email: flavia@offsetdesigndraft.com Contact information of person completing this checklist (if different than above): Name: Flavia Gomes Contact Phone: 858-344-7702 Company name/address: Offset Design Draft/ 3509 Del Rey St. Contact Email: flavia@offsetdesigndraft.com B-50 CITY Page 1 of 7 Revised 12122 Use the table below to determine which sections of the Ordinance checklist are applicable to your project. For alterations and additions to existing buildings, attach a Permit Valuation breakdown on a separate sheet. For purposes of determining valuation, the amount should be upon either the actual contract price for the work to be permitted or shall be determined 'Mth the use of the current "ICC Building Valuation Data" as published by the International Code Council, whichever is higher (refe,:to Section 18.04.035 of the CMC). Building Permit Valuation (BPV) $ breakdown ....:..$_4_5..:..,0_0_0_._0_0 _____ _ Construction Type I Complete Section(•) I Notes: I] Residential □ New construction 2A*, 3A*, 4A* *Includes detached, newly constructed ADU l!!!I Additions and alterations: l!!!I BPV < $60,000 N/A All residential additions and alterations □ BPV;? $60,000 1A,4A 1-2 family dwellings and townhouses 'Mth attached garages □ Electrical service panel upgrade only only. *Multi-family dwellings only where interior finishes are □ BPV;? $200,000 1A, 4A* removed and significant site 'M>rk and upgrades to structural and mechanical, electrical, and/or plumbing systems are orooosed 28* *Multi-family dwellings only where ;?$1 ,000,000 BPV AND BPV :2: $1,000,000 affecting .:75% existing floor area D Nonresidential and hotels/motels □ New construction 18, 28, 38, 48 and 5 □ Alterations: □ BPV.: $200,000 or additions.: 18,5 1,000 square feet □ BPV;? $1,000,000 18,28,5 Building alterations of.: 75% existing gross floor area ;? 2,000 sq. ft. new roof addition 28,5 18 also applies if BPV.: $200,000 Instructions: 1. Choose first between residential or non-residential based on the type of project being submitted. 2. Next chose between new construction or addition/alteration for residential or non-residential. 3. The columns to the right of your selection will determine which sections of the CAP program are applicable to your project. 4. Appropriate details must be included on the plans for selections made. EXAMPLE: Scope of work includes a new, 2 story, single family residential structure. The selections would be: Residential and New construction in the table above. For a 2-story structure, CAP sections 2A, 3A and 4A would be applicable. (Solar PV, water heating, EV charging) The* indicates that new detached ADU's are included. EXAMPLE: Scope of work includes a tenant improvement (i.e., alterations) valued at over one million dollars. The selections would be: Non-residential and Alteration BPV.?: $1,000,000. CAP sections 1 B, 2B and 5 would be applicable to this project. (Energy efficiency, Solar PV and Transportation Demand Management (TOM)*) It may be necessary to supplement the completed checklist 'Mth supporting materials, calculations or certifications, to demonstrate full compliance 'Mth CAP ordinance requirements. For example, projects that propose or require a performance approach to comply 'Mth energy-related measures 'MIi need to attach to this checklist separate calculations and documentation as specified by the ordinances . . I 3 CAP Ordinance Compliance Checklist Item Check the appropriate boxes, explain all not applicable and exception items, and provide supporting calculations and documentation as necessary. 1. Energy Efficiency Please refer to Section 18.30.060 of the Carlsbad Municipal Code (CMC) and Section 150.2 of the CEC for more information. Appropriate details and notes must be placed on the plans according to selections chosen in the design. A. 0 Residential addition or alteration i:!:: $60,000 building permit valuation. Details of selection chosen below must be placed on the plans referencing CMC 18.30.060. □ N/A ________ _ □ Exception: Home energy score '?:.7 (attach certification) Year Built Single-family Requirements Multi-family Requirements □ Befi:Jre1978 Select one option: □ Duct sealing □ Attic insulation □Cool roof □ Attic insulation □ 1978 and later Select one option: □ Lighting package □ VVaterheating package □ Between1978-1991 Select one option: □ Duct sealing □ Attic insulation □ Cool roof ~ 1992 and later Select one option: □ Lighting packa<1e □ Water-heating package B. 0 New Nonresidential construction (including additions over 1,000sf), new hotel/motel construction AND alterations i:!:: $200,000 building permit valuation. See Section 18.21.050 of the CMC and CALGreen Appendix AS. At least one measure from each applicable building component required. 0 NtA residential SFR A5.203.1 .1 Choose one: D Outdoor lighting D Restaurant service water heating (Section 140.5 of the CEC) D Warehouse dock seal doors □ Daylight design PAFs D Exhaust air heat recovery 0 NIA residential SFR AS.203.1 .2.1 Choose one: □ .95 Energy budget (Projects 'Mth indoor lighting OR mechanical) □ .90 Energy budget (Projects Vvith indoor lighting AND mechanical) 0 NIA residential SFR AS.211.1 ** □ On-site renewable energy: 0 NtA residential SFR AS.211 .3** □ Green power: (If offered by local utility provider, 50% minimum renewable sources) 0 NtA residential SFR AS.212.1 □ Elevators and escalators:(Project wth more than one elevator or too escalators) 0 N/Aresidential SFR A5.213.1 □ Steel framing: (Provide details on plansforoptions 1-4 chosen) 0 N/A residential SFR * High-rise residential buildings are 4 or more stories. ** For alterations;,: $1,000,000BPV and affecting> 75%existing gross floor area, OR alterations that add 2,000 square feet of new roof addition: comply with Section 18.030.040 of the CMC (section 2B below) instead. 4 2. Photovoltaic Systems A. 0 Residential new construction. Refer to Section 150.1(c)14 of the CEC for single-family requirements and Section 170.2(d) of the CEC for multi-family requirements. If project includes installation of an electric heat pump water heater pursuant to CAP section 3 below (residential water heating), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use addttional CFA orSARA #d.u. Calculated k\Ndc• Exception sheets if necessary) D D D □ Total System Size: k\M:lc kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.) 'Formula calculation where CFA = conditional floor area, #du = number of dwellings per plan type If proposed system size is less than calculated size, please explain. B. 0 Nonresidential, hotel/motel and multifamily additions, alterations and repairs of these projects 2:$1,000,000 BPV AND affecting 2:75% existing floor area, OR addition that increases roof area by 2:2,000 square feet. Please refer to Section 18.30.040 and 18.30.070 of the CMC when completing this section. Choose one of the following methods: (Gross floor area or Time-Dependent Valuation method) D Gross Floor Area (GFA)Method GFA: Min.System Size: kWd D If< 1 O,00Os.f. Enter: 5 kVVdc D If <!: 1 0,OOOs.f. calculate: 15 kWdc x (GFA/10,000) •• **Round building size factor to nearest tenth, and round system size to nearest whole number. D Time-Dependent Valuation Method C. 0 Annual TDV Energy use:*** ______ .x .80= Min. system size: ______ k\M:lc ***Attach calculation documentation using modeling software approved by the California Energy Commission. • All newly constructed non residential, hotel/motel and highrise multifamily buildings that are required by CEC section 140.10(a) to have a PV system shall also have a battery storage system meeting CEC section 140.10(b). Non residential, hotel/motel and multifamily additions, alterations or repairs that trigger solar due to the Carlsbad Climate Action Plan will NOT require battery storage. Battery storage is required when triggered by CEC section 140.10(a) and/or 170.2(g). 5 3. Water Heatin A. Residential. Refer to Section 18.30.050 of the CMC and Sections 150.1(c)8 or 170.2(d) of the CEC when completing this section. Provide com lete details on the fans. Residential new construction and alterations: l!!!I Required: 60% of energy needed for service water heating from on-site solar or recovered energy. For systems serving individual units, choose one system: □ Single 240-volt heat pump water heater AND compact hot water distribution AND Drain water heat recovery (low-rise residential only) □ Single 240-volt heat pump water heater AND PV system .3 kWdc larger than required. □ Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher. □ Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors □ Gas or propane system with a solar water hearing system and recirculation system. For systems serving multiple units, choose one system: □ Heat pump water heating system with recirculation loop tank and electric backup. □ Solar water heating system that is either: □ .20 solar savings fraction □ .15 solar savings fraction, plus drain water heat recover OR: □ System meets performance compliance requirements of section 150.1 (d) or 170.2(d) and deriving at least 60% of energy from on-site solar or recovered energy. □ Exception:. _____________________________________ _ B. Nonresidential and hotel/motel new construction. This section also applies to high-rise residential. Refer to Sections 18.030.020 and 18.040.030 of the CMC and Sections 140.5 and 170.2 of the CEC when completing this section. Provide complete details on the plans. 1. Non-residential: □ Required: Water heating system derives at least 40% of its energy from one of the following: □ Solar-thermal □ Photovoltaics □ Recovered energy □ Required: High-capacity service water heating system 2. Water heating system is (choose one): D Heat pump water heater □ Electric resistance water heater(s) D Solar water healing system with .40 solar savings fraction 3. Hotel/motel: □ Required: High-capacity service water heating system (meeting Section 170.2(d) of the CEC) □ Required: Located in garage or conditioned space Exception: not applicable 6 5. D Transportation Demand Management (TOM): Nonresidential ONLY An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to determine whether your permit requires a TOM plan. If TOM is applicable to your permit, staff will contact the applicant to develop a site-specific TOM plan based on the permit details. Acknowledgment: Employee ADT Estimation for Various Commercial Uses Use EmpADTfor first 1,000 s.f. EmpADTI 1000s.f.1 Office (all)2 20 Restaurant 11 Retaib 8 Industrial 4 Manufacturing 4 \/Varehousing 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 10thEdition 13 11 4.5 3.5 3 2 For all office uses, use SANDAG rate of 20 ADT/1,000 sf to calculate employee ADT 3 Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. (8,334 sf/ 1,000 x 4.5) + 8 = 46 Employee ADT I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a TOM plan and understand that an approved TOM plan is a condition of permit issuance. Applicant Signature: /~ . Name: Flavia GoiK"es Date: 03-27-2024 Phone No.: 858-344-7702 8 4. Electric Vehicle Charging A □ Residential • New construction and major alterations.• This section also applies to hoteUmotel projects. Refer to Section 18.21.030 of the CMC and Section 4.106.4 of the GBSC when com letin this section. Choose one: D One and tv.o-family residential dwelling alterations with attached private garage. (not required if a panel upgrade would be needed) D New detached ADU. (no EV space required when no additional parking facilities are added) D New one and tv.o-family reSKlential c!v.emngs and townhouse with attached private garage. D One EV Ready parking space required l!!!I Exception: not applicable simple interior remodel D Newand l11cp' alterations to multi-family and hotel/motel projects: D Exception: ________________ _ Total Pai<ing Spaces Proposed EVSE Spaces EV Capable (10% of total) I EV Ready (25% of Toti! I EV chargers (5% ofT otal) I I *Major alterations are: (1) for one and two-family dwellings and for town houses with an attached garage, alterations have a building permit valuation ~$60,000 or include an electrical service panel upgrade. (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation~ $200,000, interiorfinishesa re removed and significant siteworka nd u pgradesto structural and mechanical, electrical, a nd/orp lumbing systems are proposed. B. D Non-Residential -New construction D Exception : _____________ _ Please refer to Section 18.21.040 of the CMC when completing this section Total Parking Spaces Prooosed EV Capable I EVCS (Installed with EVSE) I EV Ready (optional) I EV Space (optional) I I I Calculation: Refer to the table below: Total Number of Parking Spaces provided Number of required EV Capable Spaces Number of required EVCS ~nstalled .,.,;th EVSE) □ 0-9 1 1 □ 10-25 4 1 □ 26-50 8 2 □ 51-75 13 3 □ 76-100 17 5 □ 101-150 25 6 □ 151-200 35 9 □ 201 andover 20 percent of total 25 percent of Required EV Spaces Calculations: Total EV Capable spaces= .20x Total parking spaces proposed (rounded upto nearest whole number) EVSE Installed = Total EVSE Spaces x .25 (rounded up to nearest whole number) EVSE other may be "EV Ready" or "EV Space· 7 C_cityof Carlsbad CLIMATE ACTION PLAN (CAP) COMPLIANCE CAP Building Plan Template B-55 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov The following summarizes project compliance with the applicable Climate Action Plan ordinances of the Carlsbad Municipal Code and California Green Building Standards Code (CALGreen), current version. The following certificate shall be included on the plans for all building permits that are required to comply with the CAP measures: 1. ENERGY EFFICIENCY APPLICABLE: Dves [j] NO Complies with CMC 18.30.060 or 18.21.050 0 Yes li]N/A Existing Structure, year built: ____ _ Prepared Energy Audit? D es D No Energy Score: _____ _ Efficiency Measures included in scope: 2. PHOTOVOLTAIC SYSTEM APPLICABLE: □YES [ijNO Complies with CMC section 18.30.040 and 2022 California Energy Code section 150.l(c)14 D Yes ~/A Size of PV system (kWdc): Sizing PV by load calculations If by load Calculations: D Yes 0No Total calculated electrical load: 80% of load: Exception Requested Exception Approved BYes~ Yes 0No 3. ALTERNATIVE WATER HEATING SYSTEM APPLICABLE: □ YES [ijNO 4. s. Complies with CMC sections 18.30.020 18.20.030 and/or 18.30.050? Alternative Source: □ Electric □ Passive Solar Exception Requested Exception Approved ELECTRIC VEHICLE (EV) CHARGING APPLICABLE: DYes 0Yes DYES □No □No [i)No Complies with CMC section 18.21.030? Panel Upgrade? □ Yes IZJN/A D Yes 0No Required Provided Total EV Parking Spaces: No. of EV Capable Spaces: No. of EV Ready Spaces: No. of EV Installed Spaces: Hardship Requested Hardship Approved --nves □Yes TRAFFIC DEMAND MANAGEMENT APPLICABLE: Compliant? TOM Report on file with city? 0No □No □ YES IZJNO 0 Yes [Z]No DYes [Z)No Building Permit Finaled Revision Permit Print Date: 07/07/2025 Job Address: 2158 TWAIN AVE, CARLSBAD, CA 92008-4617 Permit No: Status: (cityof Carlsbad PREV2024-0140 Closed -Fina led Permit Type: BLDG-Permit Revision Work Class: Residential Permit Revision Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: 2081802400 Track#: $65,479.04 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: CBR2024-0501 Plan Check#: Applied: 07/17/2024 Issued: 09/23/2024 Finaled Close Out: 07/07/2025 Final Inspection: INSPECTOR: Description: MCCULLOCH: PROPOSED 90 SF LAUNDRY ROOM ON 2ND FLOOR// PROPOSED 100 AMP SUBPANEL IN EXISTING GARAGE Applicant: OFFSET DESIGN FLAVIA GOMES 3509 DEL REY ST, # UN IT 213 SAN DIEGO, CA 92109-5755 FEE THIRD PARTY REVIEW -Consultant Cost (BLDG) Property Owner: MCCULLOCH ANDREW AND MELISSA LIFE TRUST 03-31-22 2158 TWAIN AVE CARLSBAD, CA 92008-4617 Total Fees: $420.00 Total Payments To Date: $420.00 Building Division Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov AMOUNT $420.00 $0.00 Page 1 of 1 ,r= . f PLAN CHECK REVISION OR ~ C1cy o~EC ~ED susM1TTAL Development Services Building Division 1635 Faraday Avenue 442-339-2719 www.carlsbadca.gov C 1 b d APPLICATION af S a AUG 3 0 2024 8-15 ~A_,;;,.1.\,/,.\~ '~ (byCityStaflJ Original Plan Check Nu~~; LQ LUZ~~Oo01 L:.P.::la;:,,:,n~Re:;,;v:.:,;is;:.:,;io~n.:..:..::N:.;;:u~m.:.:;b~e;.:_r..;;;;;;;;; ..................... ;;;;;;;;1 Project Address 2158 Twain ave., Carlsbad, CA 92008 CONSTRUCTION CHANGE FROM APPROVED PERMIT CBR2024-0501 General Scope of Revision/Deferred Submittal: __________________ _ -PROPOSED LAUNDRY OF 90 S.F. ON 2ND FLOOR, AND PROPOSED SUBPANEL BOARD OF 100 AMP IN THE TWO-CAR GARAGE. CONTACT INFORMATION: N Flavia Gomes -Offset Design Ph 858.344.7702 Fa ame____________ one .__ _______ _ Add 3509 DEL REY STREET, UNIT 213 c· SAN DIEGO z· 92109 ress ___________________ Ity ______ IP ----- Email Address FLAVIA@OFFSETDESIGNDRAFT.COM Original plans prepared by an architect or engineer. revisions must be signed & stamped by that person. 1 . Elements revised: [i] Plans D Calculations D Soils D Energy D Other 2. 3. Describe revisions in detail List page(s) where each revision is shown SCOPE OF WORK, SHEET INDEX, AND PROJECT INFORMATION CHANGED TS.1 STUDY ROOM ON 2ND FLOOR TO BE PARTIALLY CONVERTED INTO LAUNDRY A1.2 PROPOSED SUBPANEL BOARD OF 100 AMP LOCATED IN THE TWO-CAR GARAGE. A1.3 PROPOSED LAUNDRY ON 2ND FLOOR A1.4 UPDATED DOOR SCHEDULE A6.1 UPDATED ELECTRICAL PLAN: PROPOSED SUBPANEL E1 .1 NEW SHEET -PROPOSED LAUNDRY: ELECTRICAL PLAN E1.2 4. Does this revision, in any way, alter the exterior of the project? Oves ~No 5. Does this revision add ANY new floor area(s)? OYes ~No 6. Does this revision affect any fire related issues? OYes ~No 7. Is this a full set replacement /all sheets)? OYes ~No ~Signature _________________ _ Date 08/27/2024 1635 Faraday Avenue, carlsbad, CA 92008 ftr 760-602-2719 Eal.I;: 760-602-8558 Email: building@carlsbadca.gov www.cadsbadca.gov September 9, 2024 City of Carlsbad Community Development Department -Building Division 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review: Revision Residential Interior Remodel Address: 2158 Twain Ave, Carlsbad CA Applicant Name: Flavia Gomes Applicant Email: flavia@offsetdesigndraft.com OCCUPANCY AND BUILDING SUMMARY: Occupancy Groups: R-3/U Occupant Load: NIA Type of Construction: V-B Sprinklers: No Stories: 2 Area of Work (sq. ft.): 90 sq. ft. The plans have been reviewed for coordination with the permit application. Valuation: See Notes Below Scope of Work: Confirmed Floor Area: Confirmed Notes: Valuation was not provided in the pennit application. Attn: Building & Safety Department, _J True North COMPLIANCE SERVICES City of Carlsbad -FINAL REVIEW City Pe1mitNo: PREV2024-0140 True North No.: 24-018-627 True North Compliance Services, Inc. has completed the final review of the following documents for the project referenced above on behalf of the City of Carlsbad: I. 2. 3. Drawings: One (I) copy dated August 27, 2024, by Offset Design. Structural Calculations: One (I) copy dated August 13, 2024, by Miles Lovelace. B-15 Application: One (I) copy by Flavia Gomes. The 2022 Californ ia Building, Mechanical, Plumbing, and Electrical Codes (i.e., 2021 JBC, UMC, UPC, and 2020 NEC, as amended by the State of California), 2022 California Green Building Standards Code, 2022 California Existing Building Code, and 2022 California Energy Code, as applicable, were used as the basis of our review. Please note that our review has been completed and we have no further comments, however, we bring the following to your attention: I. This project is Hourly. Please charge the applicant the fo llowing hours of plan review. True North Compliance Services, Inc. 8369 Vickers Street, Suite 207, San Diego, CA 92111 T / 562.733.8030 Review No. Hourly Rate Hours Total 1st Review $120.00 1 $120 2nd Review /final $120.00 2.5 $300 Total $420.00 We have enclosed the above noted documents bearing our review stamps for your use. Please call if you have any questions or if we can be of further assistance. Sincerely, True North Compliance Services Review By: Jasmine Safaqa -Plan Review Engineer Transmittal Letter July 23, 2024 City of Carlsbad Community Development Department -Building Division 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review: Revision Residential Interior Remodel Address: 2158 Twain Ave, Carlsbad CA Applicant Name: Flavia Gomes Applicant Email: flavia@offsetdesigndraft.com ..... True North COMPLIANCE SERVICES FIRST REVIEW City Permit No: PREV2024-0140 True North No.: 24-018-627 True North Compliance Services, Inc. has completed the review of the following documents for the project referenced above on behalf of the City of Carlsbad. Our comments can be found on the attached list. 1. Drawings: One (1) copy dated July 16, 2024, by Offset Design. Attn: Permit Technician, the scope of work on the plans has been reviewed for coordination with the scope of work on the permit application. See below for information if the scope of work on plans differs from the permit application: Valuation: Scope of Work: Floor Area: See Notes Below Confirmed Confirmed Notes: Valuation was not provided in the permit application. This project is hourly. Please charge the applicant the following hours of plan review. Review# Hours Rate Total pt 2 $120.00 $240.00 Our comments follow on the attached list. Please call if you have any questions or if we can be of further assistance. Sincerely, True North Compliance Services Review By: Jasmine Safaqa -Plan Review Engineer True North Compliance Services1 Inc. 8369 Vickers Street, Suite 207, San Diego, CA 92111 T / 562. 733.8030 Revision Residential Interior Remodel 2158 Twain Ave July 23, 2024 Plan Review Comments HARD COPY -RESUBMITTAL INSTRUCTIONS: City of Carlsbad-FIRST REVIEW City Permit No.: PREV2024-0140 True North No.: 24-018-627 Page2 Please do not resubmit plans until all departments have completed their reviews. For status, please contact building@carlsbadca.gov Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). Corrected sets can be submitted as follows: Deliver THREE corrected sets of plans and TWO corrected calculations/reports directly to the City of Carlsbad Building Division, 1635 Faraday Ave., Carlsbad, CA 92008, (442) 339-2719. The city will route the plans to True North, Planning and Land Development Engineering Departments (if applicable) for continued review. Note: If this project requires FIRE PREVENTION review, ensure that you follow their specific instructions for resubmittal review. The city will not route plans back to Dennis Grubb & Associates for continued Fire Prevention review. GENERAL INFORMATION: A. The following comments are referred to the 2022 California Building, Mechanical, Plumbing, Electrical Codes, California Green Building Standards Code, and Energy Code (i.e., 2021 IBC, UMC, UPC, and 2020 NEC, as amended by the State of Cal ifornia). B. There may be other comments generated by the Building Division and/or other City departments that will also require your attention and response. This attached list of comments, then, is only a portion of the plan review. Contact the City for other items. C. Respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which details, specification, or calculation shows the required information. Your complete and clear responses will expedite the re-check. D. Where applicable, be sure to include the architect and engineer's stamp and signature on all sheets of the drawings and on the coversheets of specifications and calculations per CBPC 5536.1 and CBPC 6735. This item will be verified prior to plan approval. E. If you have any questions regarding the comments below, please contact Jasmine Saffaqa via email jasmines@tncservices.com or telephone (562) 733-8030. OCCUPANCY & BUILDING SUMMARY: Occupancy Groups: Type of Construction: Sprinklers: Stories: Area of Work (sq. ft.): R-3/U V-B No 2 90 sq. ft. Revision Residential Interior Remodel 2158 Twain Ave July 23, 2024 ARCIDTECTURAL COMMENTS: City of Carlsbad-FIRST REVIEW City Permit No.: PREV2024-0140 True North No.: 24-0l8-627 Page3 Al. Sheets Al.1, Al.3, and El.l: Please remove the "No Work Proposed" label as there is a proposed panel in the garage. A2. The permit application specifics that the revision will affect a fire related issue, please clarify how and specify the exact issue. • -• -• ·-·-· ......... •y .,c,y, a1tl;".'I ll IC: L'Xlt'nor OT rne pro1cct? 5. Docs this tt'visror ac..ld A NY new floor a1<-,:1(s)? 6. Co ·s this rev1sio--· affect any fire rc,ratcd issue!? 7 • Is this a 'u11 set re,;;laccrrent (dll st'ectsJ? MECHANICAL COMMENTS: M 1. The following comments apply to the washer/dryer: a) Specify fuel source for the proposed dryer, l_JYes G~Y?s [~Y~s r-1v, ... i) For gas burning appliance, specify size, method, and source of combustion air per CMC 701.4. Alternatively specify doors to be louvered. ii) For electric powered appliances, specify a 30 AMP circuit per CEC 220.54. b) Note the following on the plans: i) Exhaust duct termination is as follows per CMC 502.2: ( 1) 3 feet from a property I ine, (2) l 0 feet from a forced air inlet, and (3) 3 feet from openings into the building. ii) Exhaust duct shall not discharge onto a public way. CMC 502.2 iii) Unless otherwise permitted or required by the dryer manufacturer's installation instructions and approved by the city, domestic dryer moisture exhaust ducts shall not exceed a total combined horizontal and vertical length of fourteen feet, including two 90-degree elbows. Two feet shall be deducted for each 90-degrcc elbow in excess of two. CMC 504.4.2. ELECTRICAL COMMENTS: E 1 . In the laundry room, a) Provide at least one receptacle outlet per CEC 2 l 0.52(F). b) Receptacle outlet shall be GFCI protected where it is within 6 feet of a sink. CEC 210.8. PLUMBING COMMENTS: No comments. Revision Residential Interior Remodel 2158 Twain Ave City of Carlsbad-FIRST REVIEW City Permit No.: PREV2024-0140 True North No.: 24-018-627 Page4 July 23, 2024 GREEN BUILDING COMMENTS: G l . Climate Action Plan requirements apply to all new structures, residential additions/remodels equal to or exceeding $60,000 in valuation, and commercial City of Carlsbad requires that all projects that qualify for CAP compliance will require a completed Climate Action Plan (CAP) Consistency Checklists ( city forms B-50) to be completed by the APPLICANT. https://www.carlsbadca.gov/home/showpublisheddocument/6878/638225157825900000 a) For plans submitted to the City the following Climate Action Plan requirements apply, per Carlsbad ordinance: b) The applicant is to fill out the B-50 CAP Consistency Checklist. The scope of work and project valuation will determine which sections of the CAP are requ ired. c) Plan examiners review the B-50 CAP Consistency Checklist for completion. For example: If new residential construction is the scope of work, CAP sections 2A, 3A, and 4A are required to be filled on the B-50 checklist. ENERGY COMPLIANCE COMMENTS: Tl. Revise plan to show at least one luminaire in the laundry room to be controlled by a vacancy sensor. CEnergyC 150.0(k)2(E) STRUCTURAL COMMENTS: No comments. If you have any questions regarding the above comments, please contact Jasmine Saffaqa via email jasmines@tncservices.com or telephone (562) 733-8030. rEND] 0ffsGt design + drafting RESPONSE LETTER -RECORD ID: PREV2024-014O Date: August 27th, 2024 ATT: Jasmine Saffaqa 1STREVIEW-CONSTRUCTION CHANGE GENERAL INFORMATION A. NOTED !3. NOTED C. NOTED D. NOTED E. NOTED OCCUPANCY & BUILDING SUMMARY 1. PLEASE SEE SHEET -TS.1 UNDER PROJECT INFORMATION. AND SCOPE OF WORK Offset Design Draft 1 of 2 3509 Del Rey Street Unit 213, San Diego -California -92109 0ffsGt design + drafting ARCHITECTURAL COMMENTS: A1 PLEASE SEE UPDATED SHEET -A1 .1 AND A 1.3 -NOTE REMOVED A2. PLEASE SEE UPDATED FORM ATTACHED MECHANICAL COMMENTS: M1 A. ifLEASE SEE UPDATED SHEET -E1 .2 -MECHANICAL LEGEND: STACKABLE WASHER/DRYER GE PRO- FILE 4.8 CU. FT. CAPACITY ULTRAFAST COMBO WITH VENTLESS HEAT PUMP TECHNOLOGY WA~ER/DRYER -PFQ97HSPVDS ~_,,,__..., ll 11 '' JS.l.2. ~"-AL-~·. !i='.,6.f,.J:el-'1:x:,>,(2 '.I:> -~ B. 0 DUCT PROPOSED -COMMENT CLEARED OFF BY REVIEWER ELECTRICAL COMMENTS: -At A. PLEASE SEE UPDATED SHEET -E1 .2 -ELECTRICAL LEGEND: GFCI AND SYMBOLS PLACED ON LAUNDRY WALLS -ELECTRICAL FLOOR PLAN ~ C,. PLEASE SEE UPDATED SHEET -E1 .2-ELECTRICAL LEGEND: GFCI AND SYMBOLS PLACED ON LAUNDRY WALLS -ELECTRICAL FLOOR PLAN GREEN BUILDING COMMENTS: G1 PROJECT DOES NOT EXCEED $60,000.00 -COMMENT CLEARED OFF BY REVIEWER ENERGY COMPLIANCE COMMENTS: T1 PLEASE SEE UPDATED SHEET -E1 .2 -ELECTRICAL LEGEND: MV-VACANCY SENSOR AND SYMBOL PLACED IN THE LAUNDRY OUTLET -ELECTRICAL FLOOR PLAN STRUCTURAL COMMENTS: PLEASE SEE STRUCTURAL PLANS, CALCULATION AND RESPONSE LETTER Offset Design Draft 3509 Del Rey Street Unit 213, San Diego -California -92109 .__ _ ___, .i MCCULLOCH RESIDENCE STRUCTURAL CORRECTIONS PROJECT# CBR2024-501 D ADDITIONAL GHANGES OPENING SIZE ING'REASED LEADING TO ADDITION OF SHEA-R ALONG eRID LINE A AND BLOGKING AND STRAPS FOR DRAGGING SHEA-R LOADS. OPENING HEIGHT INCREASED-REDIJC,ING AVAILABLE SPAGE FOR BEAM. BEAM SIZING ON 53 CHANGED AND DETAIL 3/55 UPDATED. LATERAL (L-8 -L-11) AND VERTICAL (V-1 -V-5) CALCULATIONS UPDATED TO-REFLECT CHANGES. EXISTING WALLS GONFtRMED TO BE 2x4 FRAMED. FH-1/RH-I CHANGED TO 4x6 FROM 6x6 AND CALCULATIONS UDPATED. LOVELACE I= GINl=F ING STRUCTURAL ENGINEER IN G SE RVICE S STRUCTURAL CALCULATIONS DATE: PROJECT: DESIGNER: JOB: AUGUST 73, 2024 MCCULLOCH RESIDENCE 2758 TWAIN AVENUE SAN D I EGO, CA 92008 OFFSET DESIGN+ DRAFTING 35098 DEL REY, UNIT 273 SAN DI EGO, CA 92709 ]24075 858.535.9lll I fax 858.535.1989 I www.lovelaceeng.com --10509 Vista Sorrento Pkwy, Suite 102 San Diego, CA 92121 LOVELACE r=NGINEERI G SHEET NO. Joe J24015 -MCCULLOGH RESIDENCE TG-1 OF ------- CALCULATEDBY _______ G_._K_. -DATE _____ _ STRUCTU RA L ENG IN EERING SERV I C E S CHECKEDBY __________ DATE _____ _ 10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121 phone858.535.9111 • fax858.535.1989 • www.lovelaceeng.com SCALE __________________ _ TABLE OF CONTENTS SUBJEG T SHEET DESl6N CRITERIA ...................................................................................................................................................... DG-1 DESl6N LOADS........................................................................................................................................................... DL-1 VERTICAL ANAL YSIS/DESl6N .............................................................................................................................. V-1/5 LATERAL ANAL YSIS/DESl6N ............................................................................................................................... L-1/13 FOUNDATIONS/ -RETAININ6 HALLS ................................................................................................................... f -1/2 STRUCTURAL NOTES/ SCHEDULES/ DETAILS (HHERE APPLICABLE) ............................................ . TOTAL LOVELACE FNGltJEERING Joa J24015 -MCCULLOGH -RESIDENCE SHEET NO. DG-1 OF ------- CALCULATED BY _______ G_.K_._ DATE _____ _ STRU C TURAL EN G INEERING S ERVI C ES CHECKEDBY __________ DATE _____ _ 10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121 phone 858.535.91 11 • fax 858.535.1989 • www.lovelaceen9.com SCALE __________________ _ DESIGN CRITERIA GOVERNING GODE, CBC 2022 CONCRETE, AGI 318-19 F'c.=2500 psi, NO SPECIAL INSPECTION REQ'D. (U.N.O.) MASONRY, TMS 402-16 / AGI 530-13 MEDIUM HEl6HT, ASTM GC!O, F'm= 1500 psi, SPECIAL INSP. REQ'D MORTAR, ASTM G210, F'c.=1800 psi, TYPES GROUT, ASTM CA16, F'c.=2000 psi REINFORCING STEEL: ASTM A615, F~= 40ksi FOR # 4 AND SMALLER ASTM A615, F~= 60ksl FOR# 5 AND LAR6ER (U .N.O.) STRUC TURAL STEEL: AISG 360-16, 15TH EDITION BOLTING, HELDING, HOOD: GLULAMS, SOIL: ASTM A512, F~= 50 ksl (STEEL SHAPES) U.N.O. ASTM A500, GRADE B, F~= 46ksl (STRUCTURAL TUBE) ASTM A53, GRADE B, F~= 35ksl (STRUCTURAL PIPE) ASTM A36, F~= 36 ksl (PLATES) A301, SINGLE PLATE SHEAR CONN. A325-N, A490-N HIGH STRENGTH, SINGLE PLATE SHEAR CONN. ElOXX SERIES-TYP., EC!O SERIES FOR A615 GRADE 60 REBAR SHOP HELDING TO BE DONE IN AN APPROVED FABRICATOR'S SHOP FIELD HELDING TO HAVE CONTINUOUS SPECIAL INSPECTION. NDS-18 DOUGLAS FIR LARCH 24F-V4 FOR SIMPLE SPAN CONDITIONS 24F-V8 FOR CANTILEVER CONDITION ALLOHABLE BEARING PRESSURE ACTIVE SOIL PRESSURE =1500 = AT -REST SOIL PRESSURE (-RESTRAINED) = __ _ PASSIVE SOIL PRESSURE = __ _ LATERAL EARTHQUAKE PRESSURE = __ _ COEFFICIENT OF FRICTION = --- 181 EXISTING NATURAL SOIL PER CBC TABLE 18062 SOILS REPORT BY, PROJECT NUMBER, DATED, psf pc.F pc.F pc.F pc.F LOVELACE JOs -124015 -MCCULLOCH RESIDENCE SHEET NO DL-1 OF -------ENGl~I= DING CALCULATEDBY _______ C_._K_. -DATE _____ _ STRUC TURAL ENGINEERING SERV I CES CHECKEDBY __________ DATE _____ _ 10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121 phone858.535.9111 • fax858.535.1989 • www.lovelaceeng.com SCALE __________________ _ DESIGN LOADS 'ROOF DEAD LOAD: ROOFING (COMP.SHINGLES) ............................. . SHEATHING ................................................ . RAFTER/CEILING JOISTS OR TRUSSES ...................... . INSULATION ................................................ . DRY HALL ................................................. . OTHER (ELEC., MECH., MISC.) ............................... . TOTAL DEAD LOAD: LIVE LOAD, (ROOF USE PER IBC TABLE 1601.1) TOTAL LOAD: FLOOR DEAD LOAD, FLOORING ( CARPET a PAD ) ............................ . DEX-0-TEX ............................................... . SHEATHING ................................................ . JOISTS .................................................... . DRYHALL / STUCCO ....................................... . OTHER (ELEC., MECH., MISC.) .............................. . TOTAL DEAD LOAD: LIVE LOAD, (RESIDENTIAL USE PER IBC TABLE 1601.1) TOTAL LOAD: EXTERIOR WALL STUDS ..................................................... . DRY HALL ................................................. . INSULATION ................................................ . EXTERIOR FINISH ( STUCCO ) .............................. . OTHER (MISC.) ............................................ . TOTAL LOAD: INTERIOR WALL STUDS ..................................................... . DRY HALL ................................................. . OTHER (MISC.) ............................................ . TOTAL LOAD: 5.0 psf 1.5 3.5 1.5 2.5 1.0 15.0psf 20.0 psf 35.0psf 5.0 psf .0 2.0 3.5 2.5 2.0 15.0 psf 40.0psf 55.0 psf I.Opsf 2.5 1.5 10.0 1.0 16.0 psf I.Opsf 5.0 1.0 1.0 psf + SOLA-R 3.0 18.0psf 20.0psf 38.0psf DECK/OTHER 2.5 psf 2.5 2.0 3.5 10.0 4.5 25.0 psf 60.0psf 85.0 psf V -1 LOVELACE Joe J24015 -MCCULLOGH RESIDENCE F.NGIN FOING SHEET NO __________ OF ______ _ CALCULATEDBY ________ G_.K_._ DATE _____ _ S TRU C TURAL ENGINEERING SERVI C ES CHECKEDBY __________ DATE _____ _ 10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121 phone 858.535.9111 • fax 858.535.1989 • www.lovelaceeng.com SCALE __________________ _ LEVEL ROOF MEMBERS, BEAMS ISEE GODE GHEGK CALCULATIONS THAT FOLLOV'II SPAN= 12.5 FT. &RID LINE: _X __ _ sf)*(4'/2) 4'/2) (plf) L = -----'-c=i;;;.,d = XX D = XX Lr L 012 D=--------~"""=" __________ __:=::__ __ (plf) L= = ___________ __::_"""'--=------- 013 D=---------------=-......::---::;;;.~---- (p1FJ L= --------- Pl D=---'--'-'~~~~=~~-____:::_....,;;..af!!::.. _______ -=-=~~ (lbs) L= = = P2 D= _____ -=---,,:::::.. _____________ __:::__ __ = OR FB-1 SPAN= 18 FT. eRID LINE: (15 12sf)*(l6 '/2) = (40 12sf )*(16'/2) = Lr, (18 psf)*(4'/2) PARTIAL = (20 psf)*(4'/2) = Lr, (25 12sf )*(1'/2) = (60 12sf)*(1'/2) = Lr, (16 psf )*(8') PARTIAL = = Lr = 0110x60 STEEL HEADER OR FH-1 SPAN= 3 FT. <SRID LINE: (15 12sf)*(4'/2) = (4 0 psf)*(4'/2) = Lr, - (18 psf)*(4'/2) = (20 psf)*(4'/2) = Lr (16 psf)*(l8') = = Lr = = Lr = D xlmum -R.eae,tlons (lbs) Lr L Rm □ FULL SPAN UNIFORM LOAD 4620 5Cf0 4110 4120 630 4110 □ FULL SPAN UNIFORM LOAD I Wood Beam Lovelace Engineering, Inc. 10509 Vista Sorrento Pkwy, Ste. 102 San Diego, CA 92121 Project Title: Engineer: Project ID: Project Descr: MCCULLOCH RESIDENCE CK J24075 V -2 UC#: KW-06013959, Build:20.24.07.08 DESCRIPTION: FH-1 Lovelace Engineering, Inc. Project File: J24075 -VERTICAL.ec6 (c) ENERCALC INC 1983-2023 CODE REFERENCES Calculations per NOS 2018, IBC 2021 , ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Analysis Method : Allowable Stress Design Load Combination ASCE 7-16 Wood Species Wood Grade Beam Bracing Douglas Fir-Larch No.2 Completely Unbraced Fb + Fb - Fc -Prll Fe -Perp Fv Ft D 0288 000'.lO L004 Span •30ff 900.0 psi 900.0 psi 1,350.0 psi 625.0 psi 180.0 psi 575.0psi E : Modulus of Elasticity Ebend-xx 1,600.0 ksi Eminbend -xx 580.0ksi Density 31 .210pcf ----. Applied Loads Service loads entered. Load Factors will be applied for calculations Beam self weight calculated and added to loading Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 2.0 ft, (FLOOR) Uniform Load : D = 0.0180, L = 0.020 ksf, Tributary Width= 2.0 ft, (ROOF) Uniform Load : D = 0.0160 ksf, Tributary Width= 18.0 ft, (EXTERIOR WALL} DESIGN SUMMARY Maximum Bending Stress Ratio = 0.314 1 Maximum Shear Stress Ratio Section used for this span 4x6 Section used for this span fb: Actual = 365.83psi fv: Actual F'b = 1,166.55psi F'v Load Combination +D+L Load Combination Location of maximum on span = 1.500ft Location of maximum on span Span # where maximum occurs = Span# 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.003 in Ratio= 12706>=360 Span: 1 : L Only Max Upward Transient Deflection O in Ratio= 0 <360 nla Max Downward Total Deflection 0.011 in Ratio= 3188 >=240 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio= 0<240 nla Maximum Forces & Stresses for Load Combinations Design OK = 0.311:1 4x6 = 55.89 psi = 180.00 psi +D+L = 0.000ft = Span# 1 Load Combination Max Sfress Ratios Moment Values Shear Values Segment Length Span# M V CD CM Ct Clx cf Cfu C . I Cr M fb F'b V fv F'v DOnly 0.0 0.00 0.0 0.0 Length = 3.0 ft 1 0.261 0.258 0.90 1.00 1.00 1.00 1.300 1.00 1.00 1.00 0.40 274.0 1,050.2 0.54 41.9 162.0 +D+L 1.00 1.00 1.00 1.300 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 3.0 ft 0.314 0.311 1.00 1.00 1.00 1.00 1.300 1.00 1.00 1.00 0.54 365.8 1,166.6 0.72 55.9 180.0 +D+0.750L 1.00 1.00 1.00 1.300 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 3.0 ft 1 0.235 0.233 1.25 1.00 1.00 1.00 1.300 1.00 1.00 1.00 0.50 342.9 1,457.0 0.67 52.4 225.0 +0.600 1.00 1.00 1.00 1.300 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 3.0 ft 0.088 0.087 1.60 1.00 1.00 1.00 1.300 1.00 1.00 1.00 0.24 164.4 1,862.9 0.32 25.1 288.0 Lovelace Engineering, Inc. 10509 Vista Sorrento Pkwy, Ste. 102 San Diego, CA 92121 Project Title: Engineer: Project ID: Project Descr: MCCULLOCH RESIDENCE CK J24075 V -3 [ Wood Beam UC#: KW-06013959, Build:20.24.07.08 DESCRIPTION: FH-1 Lovelace Engineering, Inc-. -- Project File: J24075 -VERTICAL.ec6 (c) ENERCALC INC 1983-2023 Overall Maximum Deflections Load Combination +D+L Vertical Reactions Load Combination Span 1 Max Upward from all Load Conditions Max Upward from Load Combinations Max Upward from Load Cases DOnly +D+L +D+0.750L +0.60D L Only Max. "-" Defl Location in Span Load Combination Max. "+" Deft Location in Span 0.0113 1.511 0.0000 0.000 Support notation : Far left is #1 Values in KIPS Support 1 Support 2 0.717 0.717 0.717 0.717 0.537 0.537 0.537 0.537 0.717 0.717 0.672 0.672 0.322 0.322 0.180 0.180 Lovelace Engineering, Inc. 10509 Vista Sorrento Pkwy, Ste. 102 San Diego, CA 92121 Project Title: Engineer: Project ID: Project Descr: MCCULLOCH RESIDENCE CK J24075 V-4 Lste~I Beam UC#: KW-06013959, Build:20.24.07.08 -Lovelace EngineeringTnc. Project File: J24075 -VERTICAL.ec6 (c) ENERCALC INC 1983-2023 DESCRIPTION: (UPDATED) FB-1 STEEL CODE REFERENCES Calculations per AISC 360-16, IBC 2021, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method Allowable Strength Design Beam Bracing : Completely Unbraced Bending Axis : Major Axis Bending ~ __ D(2.i140 • • D(_0.~320) D 0 .1920\ r-v ' 'tr • • D(0.0875~) L(0.210) 0 DjQ..0450 Lr~~) Fy : Steel Yield : E: Modulus : .• v--0 (~ 1~@(UC>u.p;JYJ.;!i,&O~.o...7~0' ~r0.060) W10x60 Span = 18 .0 fl --1 50.0 ksi 29,000.0 ksi Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 8.0 ft, (FLOOR) Uniform Load : D = 0.0180, Lr= 0.020 ksf, Extent = 0.0 --» 6.0 ft, Tributary Width = 2.50 ft, (ROOF) Uniform Load : D = 0.0250, L = 0.060 ksf, Tributary Width = 3.50 ft, (DECK) Uniform Load : D = 0.0160 ksf, Extent= 0.0 --» 6.0 ft, Tributary Width= 12.0 ft, (EXTERIOR WALL) Uniform Load : D = 0.0160 ksf, Tributary Width= 2.0 ft, (EXTERIOR WALL) Point Load : D = 0.110, Lr = 0.060 k @ 5.0 ft, (above 1) Point Load : D = 0.730, Lr= 0.40 k@ 8.50 ft, (above 2) Point Load : D = 0.730, Lr= 0.40 k@ 14.30 ft, (above 3) Point Load : D = 0.110, Lr= 0.060 k@ 17.80 ft, (above 4) Uniform Load : D = 0.0140 ksf, Tributary Width = 1.0 ft, (hanging door) DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Ma : Applied Mn I Omega : Allowable Load Combination Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection 0.221 : 1 W10x60 41.157 k-ft 186.128 k-ft +D+L Span# 1 0.127 in Ratio= 0 in Ratio= 0.243 in Ratio= O in Ratio= Maximum Forces & Stresses for Load Combinations Load Combination Max S ress Ratios Maximum Shear Stress Ratio = Section used for this span Va : Applied Vn/Omega : Allowable Load Combination 1,698 0 889 0 Location of maximum on span Span# where maximum occurs >=720. Span: 1 : L Only <720.0 nla >=720. Span: 1 : +D+L <720.0 nla Summary of Moment Values Design OK 0.110 : 1 W10x60 9.393 k 85.680 k +D+L 0.000 ft Span# 1 Summary of Shear Values Segment Length Span# M V Mmax+ Mmax -Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega DOnly Dsgn. L = 18.00 ft 0.106 0.054 19.75 19.75 310.83 186.13 1.14 1.00 4.62 128.52 85.68 +D+L Dsgn. L = 18.00 ft 0.221 0.110 41 .16 41.16 310.83 186.13 1.14 1.00 9.39 128.52 85.68 +D+Lr Dsgn. L = 18.00 ft 0.123 0.061 22.88 22.88 310.83 186.13 1.15 1.00 5.21 128.52 85.68 +D+0. 750Lr+0. 750L Dsgn. L = 18.00 ft 0.205 0.101 38.15 38.15 310.83 186.13 1.14 1.00 8.64 128.52 85.68 +D+0.750L Dsgn. L = 18.00 ft 0.192 0.096 35.80 35.80 310.83 186.13 1.141.00 8.20 128.52 85.68 +0.60D Dsgn. L = 18.00 ft 0.064 0.032 11.85 11 .85 310.83 186.13 1.141.00 2.77 128.52 85.68 Lovelace Engineering, Inc. 10509 Vista Sorrento Pkwy, Ste. 102 San Diego, CA 92121 [ steel Beam _ Project Title: Engineer: Project ID: Project Descr: MCCULLOCH RESIDENCE CK J24075 V-5 LIC#: KW-06013959, Build:20.24.07.08 Lovelace Engineering, Inc. Project File: J24075 -VERTICAL.ec6 (c) ENERCALC INC 1983-2023 DESCRIPTION: (U PDATED) FB-1 STEEL Overall Maximum Deflections Load Combination +D+L Vertical Reactions Load Combination Span 1 Max Upward from all Load Conditions Max Upward from Load Combinations Max Upward from Load Cases D Only +D+L +D+Lr +D+O. 750Lr+O. ?SOL +D+0.750L +0.600 Lr Only LOnly Max. "." Defl Location in Span Load Combination 0.2428 9.000 Support notation : Far left is#" Support 1 Support 2 9.393 8.893 9.393 8.893 4.770 4.770 4.623 4.123 9.393 8.893 5.210 4.755 8.641 8.175 8.200 7.700 2.774 2.474 0.587 0.633 4.770 4.770 Max. "+" Defl Location in Span 0.0000 0.000 Values in KIPS ~ LOVELACE MCCULLOCH RESIDENCE ENGINEERING OFFSET DESIGN STUDIO STRUCTU RAL ENC INEERINCi SERVICES J24075 SEISMIC WEIGHT Level 1 FLOOR Typical Plate Ht. (ft.) Element Type Dead Load (psf) Area (sf) Diaphragm ROOF 18 700 Diaphragm FLOOR 15 2100 Diaphragm Dead Load I psf) Length {ft.) Wall EXTERIOR 16 220 Wall INTERIOR 7 150 Wall Dead Load (lbs.) Misc./ Concentrated Total Weight (lbs.) 80660 Seismic Weight (lbs.) Level 2 ROOF Typical Plate Ht. (ft.) Element Type Dead Load (psf) Area (sf) Diaphragm ROOF 18 2250 Diaphragm Diaphragm Dead Load (psf) Length (ft.) Wall EXTERIOR 16 215 Wall INTERIOR 7 150 Wall Dead Load (lbs.) Misc./ Concentrated Total 76420 Seismic Weight 8 Weight 12600 31500 0 Weight 28160 8400 0 Weight 0 62380 8 Weight 40500 0 0 Weight 27520 8400 0 Weight 0 76740 L-1 CK 8/8/2024 Page: ASCE. AMEIIICAN SOCIElY CJ CM. ENGINEERS Address: 2158 Twain Ave Carlsbad, California 92008 ... ·i Wind Results: Wind Speed 10-year MRI 25-year MRI 50-year MRI 100-year MRI Data Source: Date Accessed: •J'l t ' L-2 ASCE Hazards Report Standard: ASCE/SEI 7-16 Risk Category: 11 Soil Class: D -Default (see Section 11.4.3) C " P ' H ••1, 96 Vmph 66 Vmph 72 Vmph 77 Vmph 82 Vmph . . C • ' " .,, ' ' --• <' Latitude: 33.14181 Longitude: -117.298027 Elevation: 325.216969560486 ft (NAVO 88) ts-11. 11,-,10"1.H► .Kl~ \ M•0, Lt',"Rlll/1\ ) \ ' _,: I Ul ~ ' .-) j,_ ASCE/SEI 7-16, Fig. 26.5-1 B and Figs. CC.2-1-CC.2-4, and Section 26.5.2 Thu Feb 22 2024 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI= 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. https://ascehazardtool.org/ Page 1 of 3 Thu Feb 22 2024 I~ LO y E LACE PROJECT : MCCULLOCH RESIDENCE V-....: E ~., 1 N, ~ 1 J CLIENT : OFFSET DESIGN STUDIO , ,., '"'" , •• , .... ,., ""'"" JOB NO.: J24075 DATE : 03/29124 Wind Analysis for Low-rise Building, Based on 2018 IBC/ASCE 7-16 INPUT DATA Exposure category (B, C or D, ASCE 7-16 26.7.3) Importance factor (ASCE 7-16 Table 1.5·2) Basic wind speed (ASCE 7-16 26 5.1 or 2018 IBC) Topographic factor (ASCE 7-16 26.8 & Table 26.8-1) Building height to eave Building height to ridge Building length Building width, including overhangs Overhang sloped width Effective area of components (or Solar Panel area) DESIGN SUMMARY lw = V = Kzt = he= h, = L = B Oh A C 1.00 100 24 29.5 75 53 0 12 1.12 for all Category mph, (160.93 kph) Flat ft, (7.32 m) ft, (8.99 m) ft, (22. 86 m) ft, (16.15 m) ft, (0.00 m) tt2, <== Overhang? (Yes or No) m2) PAGE : DESIGN BY : CK REVIEW BY : B No Max horizontal force normal to building length, L, face Max horizontal force normal to building length, B, face Max total horizontal torsional load 32.10 kips, (143 kN), SD level (LRFD level), Typ. 22.68 kips, (101 kN) Max total u ward force ANALYSIS Velocity pressure qh = o.002ss K. K.i Kd K. v2 285.123 ft-kips, (387 kN-m) 63.90 ki s 284 kN 20.76 psf where: qh = velocity pressure at mean roof height, h. (Eq. 26.10-1 page 268) K, = velocity pressure exposure coefficient evaluated at height, h, (Tab. 26.10-1, pg 268) ~=wind directionality factor. (Tab. 26.6-1, for building, page 266) h = mean roof hei ht --~-----------------, 0.95 0.85 26.75 ft L-3 K. = ground elevation factor. (1.0 per Sec. 26.9, page 268) < 60 ft, [Satisfactory] .__ ___ <--'-M"-i-'n....LC.L'-'B), (Satisfactory] (ASCE 7-16 26.2.1) (ASCE 7-16 26.2.2) Design pressures for MWFRS p = qh [(G c p, )-(G c p, )I where: p = pressure in appropriate zone. (Eq. 28.3-1 , page 311). Pmin = 16 psf (ASCE 7-16 28.3.4) G Cpr = product of gust effect factor and external pressure coefficient, see table below. (Fig. 28.3-1, page 312 & 313) G CP 1 = product of gust effect factor and internal pressure coefficient.(Tab. 26.13-1, Enclosed Building, page 271 ) 0.18 or -0.1 8 a = width of edge strips, Fig 28.3-1, page 312, MAX[ MIN(0.1 B, 0.1 L, 0.4h), MIN(0.04B, 0.04L), 3] = 5.30 ft Net Pressures losfl Basic Load Cases ' Net Pressures losfl. Torsional Load Cases ' Roof angle 0 = 11.73 Roof angle 0 = 0.00 Roof an~le0 = 11.73 Surface GCpr Net Pressure with GCpr Net Pressure 'Nith (+GCp1) (-GCp1) (+GCp 1) (-GCpi) Surface GCpr Net Pressure with (+GCp1) (-GCp1) 1 0.46 5.78 13.25 -0.45 -13.08 -5.60 1T 0.46 1.44 3.31 2 -0.69 -18.06 -10.59 -0.69 -18.06 -10.59 2T -0.69 -4.52 -2.65 3 -0.42 -12.44 -4.97 -0.37 -11.42 -3.94 3T -0.42 -3.11 ·1.24 4 -0.35 -1 1.06 -3.59 -0.45 -13.08 -5.60 4T -0.35 -2.76 -0.90 5 0.40 4.57 12.04 Roof an ~le 8 = 0.00 6 -0.29 -9.76 ·2.28 1E 0.70 10.69 18.17 -0.48 -13.70 -6.23 Surface Net Pressure with GC01 (+GCp,) (·GC01) 2E -1.07 -25.95 -18.48 -1.07 -25.95 -18.48 ST 0.40 1.14 3.01 3E -0.60 -16.23 -8.75 -0 53 -14.74 -7.27 6T -0.29 ·2.44 -0.57 4E -0.52 -14.62 -7.14 -0.48 -13.70 -6.23 SE 0.61 8.93 16.40 6E -0.43 -12.66 -5.19 Load Case A (Transverse) Load Case B {Longitudinal) Load Case A {Transverse) Load Case B {Longitudinal) Basic Load Cases Torsional Load Cases L -4 --- Basic Load Case A Transverse Direction Basic Load Case B Longitudinal Direction) Area Pressure lk\ v,;th Area Pressure lk\ v,;th Surface (ft') (+GCp;) (-GCp;) Surface (ft') (+GCP.) (-GCp.) 1 1546 8.93 20.48 Poverhang = -14.53 psf 2 1743 -31.48 -18.45 2 1743 -31.48 -18.45 (ASCE 7-16 28.3.3) 3 1743 -19.90 -6.87 3 1743 -21.68 -8.66 4 1546 -17.09 -5.54 1E 254 2.72 4.62 2E 287 -7.44 -5.30 3E 287 -4.66 -2.51 4E 254 -3.72 -1 .82 I: Horiz. 29.91 29.91 Vert. -63.90 -34.20 Min. vvind Horiz. 32.10 32.10 28.4.4 Vert. -63.60 -63.60 Torsional Load Case A (Transverse Direction) Surface 1 2 3 4 1E 2E 3E 4E 1T 2T 3T 4T Area (ft') 646 728 728 646 254 287 287 254 900 1015 1015 900 Pressure lk\ v,;th 3.73 8.55 -13.15 -7.71 -9.06 -3.62 -7.14 -2.32 2.72 4.62 -7.44 -5.30 -4.66 -2.51 -3.72 -1.82 1.30 2.98 -4.58 -2.69 -3.16 -1.26 -2.49 -0.81 Total Horiz. Torsional Load, Mr Torsion (ft-kl 60 138 -43 -25 30 12 115 37 88 149 -49 -35 30 16 120 59 -24 -56 17 10 -12 -5 -47 -15 285 285 Design pressures for components and cladding p = qh[ (G Cp) -(G Cp;)] where: p = pressure on component. (Eq. 30. 3-1, pg 334) Pmin = 16.00 psf (ASCE 7-16 30.2.2) G Cp = external pressure coefficient. see table below. (ASCE 7-16 30.3.2) 0 = 11.73 ° Effective Zone 1 Zone 1' Area (It') GC. -GC, GC, -GC, Comp. 12 0.52 -2.00 - Effective Zone 3 Zone 3e Area (ft2) GC, -GC, GC, -GC, 12 . . 0.52 -2.89 Zone 1 Zone 1· Comp. & Cladding P..itlve NMJative Positive N-live Pressure 16.00 -45.25 ( psf) Zone 3 Zone Je Poaitlve I NeaatJve p..,.,,. Na,u,tJve 16.00 -63.66 5 1158 5.29 13.94 6 1158 -11 .29 -2.64 2E 287 -7.44 -5.30 3E 287 -4.23 -2.08 SE 260 2.32 4.27 6E 260 -3.30 -1.35 I: Horiz. 22.20 22.20 Vert. -51 .26 -21.94 Min. wind Horiz. 22.68 22.68 28.4.4 Vert. -63.60 -63.60 Torsional Load Case B (Longitudinal Direction\ Surface 2 3 5 6 2E 3E SE 6E 5T 6T Area (ft') 1743 1743 449 449 287 287 260 260 709 709 Pressure lk\ v,;th -31.48 -18.45 -19.90 -6.87 2.05 5.40 -4.38 -7.44 -4.23 2.32 -3.30 0.81 -1.73 -1.02 -5.30 -2.08 4.27 -1.35 2.13 -0.40 Torsion (ft-kl -17 -10 11 4 21 56 45 11 53 38 -30 -15 55 102 79 32 -10 -27 -22 -5 Total Horiz. Torsional Load, Mr 184.2 184.2 Walls Zone 2 GC. -GC, . . Zone 3r GC, -GC. 0.52 -3.46 Zone 2 PosJtlve H-.natJve Zone 3r Pos/t/\le N-tlv• 16.00 -75.51 :i.e-;:_2~~ kp•-;3.! I I I I I I I I 2.1 -l2r 2rl -12. :] : :1: I I I I j,~2~j,-it~n~Je il Roof 0,1• Roof o,P Zone 2e Zone 2n Zone 2r GC, -GC, GC, -GC. GC, -GC, 0.52 -2.00 0.52 -2.89 0.52 -2.89 Zone4 Zone 5 GC, -GC, GC. -GC. 0.99 -1.09 0.99 -1.37 Zone 2e Zone 2n Zone 2r Poshlvo Ne,aatlve Poshlvo N11tnat/ve Poa/1/ve N.,,.,lve 16.00 -45.25 16.00 -63.66 16.00 -63.66 Zone 4 Zone s Poaitlve N-.atlve Positive I N----.... (The Max Pressure 24.21 -26.28 24.21 -32.22 75.51 psf) ASCE. AMERK;AN SOClflY OF CIVIL ENGINEERS Seismic Site Soil Class: Results: D -Default (see Section 11 .4.3) 0.987 S01 0.36 T L : 1.2 PGA: N/A 8 0.431 Fv : 0.517 N/A PGA M: SMs 1.184 F PGA 1.2 SM1 N/A 18 : Sos 0.79 Cv : 1.294 Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Data Accessed: Thu Feb 22 2024 Date Source: USGS Seismic Design Maps https://ascehazardtool.org/ Page 2 of 3 L -5 Thu Feb 22 2024 ~ LOVELACE EN --1 ["Q "lG STRU CfUPAL ENGINEER IN G SEAVICE S MCCULLOCH RESIDENCE OFFSET DESIGN STUDIO J24075 SEISMIC BASE SHEAR II Level 2 1 Period calculation Overall Ht. System 24 All Other Systems Ts= Ta= Cch~ Ta = TL= Base Shear System R Wood Shear Walls 6.5 Site Class: F D l SDS = 0.790 SDl = 0.466 S1 = I 0.360 1 ht. {ft.) 9 15 24 ft. wx {lbs.) 76740 62380 Vertical Distribution hx 24 15 Ct X 0.02 0.7S 0.589 s 0.217 s 8 s Omega Cd 2.5 Cs = W= V= k 1 I 1 I 1 4.5 1.0 0.122 139.12 k 16.91 k Tot al Base Shear wx•hxAk Cvx 1841760 0.66310946 935700 0.33689054 2777460 CK 8/8/2024 Page: per ASCE 7, Fig. 22-14 per ASCE 712.8.1.1 Fx k 11.2 k 5.7 k Ta= Cthn x Ta= 0.217 fV = 1.940 FROM TABLES & LINEAR SM1 = S1 * fV 7' SD1/ 's = SDs SM1 = 0.698 Ts= 0.589 SD1 = C2h)SM1 1.5Ts = 0.884051 SD1 = 0.466 :. Per exception 2 of ASCE 7 -16 section 11.4.8 Ta < 1.5Ts so C5 from equation 12.8 -2 can be used and does not need to be factor ed. INTERPOLATION L-6 L -7 ~ MCCULLOCH RESIDENCE CK LOVELACE OFFSET DESIGN STUDIO 8/8/2024 ENGINEc ... Rl"'G STRUCfV RAL EN GINEE RI NG SERVICES J24075 Page: LATERAL STORY FORCES Seismic Level Fx (lbs.) Diaphragm Area (sf) ASD Story Load ( psf) 0 0.7 2 11212 2250 0.7 3.S 1 5696 2800 0.7 1.4 Wind Direction N-S A-D Force = 32.1 k Pressure= 15.3 psf Level Ht. length area Trib. Ht. ASD diaph. Load 0 Ridge/Parapet 10 75 750 5 0.6 pit 2 9 75 675 14.5 0.6 133 pit 1 9 75 675 9 0.6 83 plf 2100 sf Direction E-W 1-4 Force= 22.68 Pressure = 15.3 psf Level Ht. length area Trib. Ht. ASD diaph. Load Ridge/Parapet 10 53 530 5 0.6 plf 2 9 53 477 14.5 0.6 133 pit 1 9 53 477 9 0.6 83 pit 1484 sf I~ LOVELACE .,_.,... rt--( h:-Cll C SIRUCfUR AL E N GI NEt,RING SERVI CE~ MCCULLOCH RESIDENCE OFFSET DESIGN STUDIO J24075 Level Name Level# Lateral line ROOF 2 A Direction N-S WOOD SHEARWALL ANALYSIS & DESIGN I Area 1 2 3 4 SEISMIC LOAD SDS = 0.79 p = 1.0 Story Load SF 700 I 3.5 Factor 1.0 Total/2 = Seismic Load I ADDITIONAL SEISMIC LOAD line Segment L H H/l Ratio Load Ratio Load E Adj. Load E Load W Adj. Load w Unit Shear E Unit Shear W I I Load (lbs.) Offset Factor I Total Add. Load Total Seismic load = 1 psf Load (lbs) >«11 1221 lbs. Adjust. Load 0 1221 lbs. WIND LOAD Load Type L A ·D Load Type R Load (pit) 133 Load (pit) length l (ft.) 0 Length R (ft.) Load l (lbs.) 0 Load R (lbs.) Total/2 = Wind load 798 lbs. ADDITIONAL WIND LOAD line load (lbs.) Offset Factor ' Adjust. load I I I Total Add. Load 0 Total Wind Load = 798 lbs. SHEAR l CK 8/8/2024 Page: A·D 133 12 1596 Total Shear Length (ft.) 0 L. lbs. llbs. lbs. plf plf Max Shear 0 PLF I USE# 1 Shear Wall ! Capacity= 260 plf OTM E OTMW Wall Weight Wall UDL Unif. DL Concen. DL CDl loc. DL Moment DL Mom. E DLMom.W Net OT E NetOTW Uplift E Add. Uplift E Uplift W Add. UpliftW Tot. Uplift E Tot. Uplift W HD# OVERTURNING 16 UPLIFT I t--f---l I I • • No HD required, by inspection •• • See Perforated/ Force-Transfer Shearwall calculation L -- I #-ft. #-ft. psf plf plf lbs. 1 ft. #·ft. #-ft. #·ft. ' #·ft. #-ft. lbs. libs. lbs. lbs. lbs. lbs. L -8 CIC 1306.3 STRUCTURAL E.N G I N fE A IN C !,ERVICE!. MCCULLOCH RESIDENCE OFFSET DESIGN STUDIO J24075 Level Name level# lateral line ROOF 2 1 Direction E-W CK 8/8/2024 Page: WOOD SHEARWALL ANALYSIS & DESIGN 11 Area 1 2 3 4 SEISMIC LOAD sos= 0.79 p = 1.0 Story load SF 1000 3.5 Factor 1.0 Total/2 = Seismic Load psi load (lbs) "11 load Type l 1·4 load (plf) 133 Length l (ft.) 20 Load L (lbs.) I 2659 1744 lbs. Total/2 = Wind load ADDITIONAL SEISMIC LOAD ADDITIONAL WIND LOAD line load (lbs.) Offset Factor Adjust. Load line load (lbs.) Total Add. load 0 Total Seismic load = 1744 lbs. Total Wind load = SHEAR Segment 1 l H H/l Ratio Load Ratio load E Adj. load E LoadW Adj. load W • Unit Shear E Unit Shear W I Max Shear 0 PLF USE# 1 Shear Wall OVERTURNING OTM E OTMW Wall Weight 16 .. WallUDL Unif. DL Concen. DL COL loc. DL Moment DL Mom. E DLMom.W + Net OT E Net OTW UPLIFT Uplift E Add. Uplift E Uplift W Add. Uplift W --+ Tot. Uplift E Tot. Uplift W HD# • • No HD required, by inspection •• • See Perforated / Force-Transfer Shearwall calculation WIND LOAD load Type R 1-4 load (plf) 133 Length R (ft.) I 0 load R (lbs.) 0 1330 lbs. Offset Factor Adjust. Load Total Add. load 0 1330 lbs. Total Shear Length (ft.) 0 1 lbs. lbs. lbs. i'bs. plf /plf Capacity= 260 plf l 1 #-ft. #-ft. psi plf plf lbs. ft. #-ft. l #·ft. #-ft. #-ft. I #-ft. lbs. l ibs. lbs. lbs. I lbs. libs. L-9 Iv l'-IIIO CK2306l I~ LOVELACE ~ ENGINEERING S TR UCfURAL E NG I N EEA!NG SERVIC ES MCCULLOCH RESIDENCE OFFSET DESIGN STUDIO J24075 Level Name Level# Lateral Line FLOOR 1 A Direction N-S WOOD SHEARWALL ANALYSIS & DESIGN 11 Area 1 2 3 4 SEISMIC LOAD SDS = 0.79 p = 1.0 Story Load SF 580 150 1.4 Factor 1.0 1.0 Total/2 = Seismic Load ADDITIONAL SEISMIC LOAD Line A Segment L H H/L Ratio Load Ratio Load E Adj. Load E Load W Adj. Load W Unit Shear E Unit Shear W Load (lbs.) Offset Factor 1221 1.00 Total Add. Load Total Seismic Load = 1 2 3 3.5 9 9 3.0 2.6 _, 0.46 0.54 803 937 1205 1205 673 785 481 561 402 344 160 160 psf Load (lbs) WIND LOAD 826 Load Type L A-D Load Type R 214 Load (plf) 83 Load (plf) 0 Length L (ft.) 0 Length R (ft.) 0 Load L (lbs.) 0 Load R (lbs.) 520 lbs. Total/2 = Wind Load 660 lbs. ADDITIONAL WIND LOAD Adjust. Load Line Load (lbs.) Offset Factor Adjust. Load 1221 A 798 1.0 798 1221 Total Add. Load 798 1741 lbs. Total Wind Load = 1458 lbs. SHEAR -<----- -f-- L-10 CK 8/8/2024 Page: A-D 83 16 1321 Total Shear Length (ft.) 7 lbs. lbs. lbs. lbs. plf plf ByP:1tio CBC 2306.l Max Shear 402 PLF I USE# 3 Shear Wall Capacity= 490 plf OTM E OTMW Wall Weight Wall UDL Unif. DL Concen. DL CDL loc. OLMoment OLMom. E OLMom.W Net OT E NetOTW Uplift E Add. Uplift E Uplift W Add. Uplift W Tot. Uplift E Tot. UpliftW HD# OVERTURNING 7230 8436 #-ft. 6057 7067 #-ft. 16 16 psf 144 144 plf plf lbs. ft. 648 882 #-ft. 317 432 ~ 389 -'--529 I- 6913 8004 5669 6538 #-ft. #-ft. #-ft. #-ft. UPLIFT 2304 2287 lbs. lbs. 1890 1868 lbs. lbs. 2304 2287 lbs. 1890 1868 lbs. .. .. • -No HD required, by inspection •• -See Perforated/ Force-Transfer Shearwall calculation ~ LOVELACE f"N'3HE NG !,fRU CTUAAL E N G IN E.ERI NG S F AVICE~ Shear E 1741 Segment Adj. Shear E 2410 Adjust. Shear E 1741 ShearW 14S8 Adjust. Shear W 1042 Ll (ft.) 3.0 H above 2 ft. H opening 4 ft. H below 3 ft. Total Height 9 ft. OVERTURNING OTM E 1S666 lb.-ft. OTMW 13124 lb.-ft. Wall Weight 32 psf Wall UDL 288 plf Uniform DL 20 plf DL Moment 18634 lb.-ft. DL Moment E 9119 lb.-ft. DLMomentW 11180 lb.-ft. Net OT E 6546 lb.-ft. NetOTW 1944 lb.-ft. MCCULLOCH RESIDENCE OFFSET DESIGN STUDIO J24075 Level Name Level# Lateral line FLOOR 1 A FORCE TRANSFER SHEAR WALL II w (ft.) 4.S SHEAR Net shear to segments, non-adjusted for segment ratio Segment-adjusted shear per NDS 4.3.4 adjusted for overall H/L ratio of Force-Transfer Shear Wall Net shear to segments, non-adjusted per CBC 2306.3 Adjusted shear value per CBC 2306.3 L2 (ft.) 3.S Total Length (ft.) 11 w Perforated Length (ft.) 7 Overall H/L Ratio 0.8 Direction N-S Maximum V 158 95 plf Strap Force 383 Strap Force 1 329 197 I bs. v' 268 160 plf Strap Force 2 383 229 I bs. [JI JJ 11 ,,,..._, UPLIFT Uplift E S95 Add. Uplift E Uplift W 177 Add. Uplift W Tot. Uplift E 595 Tot. Uplift W 177 HD# 1 I I I I I I bs. bs. bs. bs. bs. bs. Shear 268 Use C516 Use# 2 i,ow v'(p\t) L -11 CK 8/8/2024 Page: lbs. plf strap 5hearWall i ;;;::: LOVELACE V ENGINEERING ST~UCTU A A L EN GIN EE R IN G SER VI CES MCCULLOCH RESIDENCE OFFSET DESIGN STUDIO J24075 Level Name Level# Lateral Line floor 1 1 Direction E-W CK 8/8/2024 Page: L -12 WOOD SHEARWALL ANALYSIS & DESIGN Area 1 2 3 4 SEISMIC LOAD SDS = 0.79 p = 1.3 Story Load SF 1150 145 1.4 Factor 1.0 1.0 Total/2 = Seismic Load psf Load (lbs) 1638 Load Type L I 1 -4 206 Load (plf) 83 0 Length L (ft.) 20 0 Load L (lbs.) 1651 922 lbs. Total/2 = Wind Load ADDITIONAL SEISMIC LOAD ADDITIONAL WIND LOAD Line Load (lbs.) Offset Factor Adjust. Load Line Load (lbs.) 1 1744 1.00 1744 1 1330 Total Add. Load 1744 Total Seismic Load = 3466 lbs. Total Wind Load = SHEAR Segment 1 2 -- L 6.5 4 H 9 9 H/L Ratio 1.4 2.3 Load Ratio 0.62 0.38 Load E 2146 1320 Adj. Load E 1485 7 LoadW 1334 821 Adj. Load W 953 586 - Unit Shear E 330 371 Unit Shear W 147 147 Max Shear 371 PLF I USE# 3 Shear Wall OVERTURNING OTM E 19311 11884 OTMW 12006 7388 Wall Weight 16 16 Wall UDL 144 144 Unit. DL Concen. DL CDL loc. DL Moment 3042 1152 DL Mom. E 1489 564 DLMom. W 1825 691 Net OT E 17822 11320 NetOT W 10181 6697 UPLIFT Uplift E 2742 2830 Add. Uplift E Uplift W 1566 1674 Add. Uplift W -1--- Tot. Uplift E 2742 2830 Tot. Uplift W 1566 1674 HD# •• .. • -No HD required, by inspection •• -See Perforated/ Force-Transfer Shearwall calculation WIND LOAD Load Type R 1 -4 Load (plf) 83 Length R (ft.) 0 Load R (lbs.) 0 825 lbs. Offset Factor Adjust. Load 1.0 1330 Total Add. Load 1330 2155 lbs. Total Shear Length (ft.) 11 lbs. lbs. By Ro11k> lbs. lbs. CBC2l06 l plf plf Capacity= 490 plf #-ft. #-ft. psf pit pit lbs. ft. #-ft. + #-ft. #-ft. 1 #-ft. #-ft. lbs. lbs. lbs. lbs. -lbs. lbs . LOVELACE ENGINEERING SfRUCf URAL E N C !NEERI N G SEAVI CES Shear E Segment Adj. Shear E Adjust. Shear E Shear W Adjust. Shear W H above 2 H opening 4 H below 3 Total Height 9 OVERTURNING OTM E 31195 OTMW 19394 e- Wall Weight 32 Wall UDL 288 Uniform DL 10 DL Moment 27155 DL Moment E 13290 DLMomentW 16293 -Net OT E 17905 NetOTW 3101 3466 1485 3466 2155 1539 Ll (ft.) ft. ft. ft. ft. I I b.-ft. b.-ft. psf plf I I I I I plf b.-ft. b.-ft. b.-ft. b.-ft. b.-ft. 6.5 MCCULLOCH RESIDENCE OFFSET DESIGN STUDIO J24075 Level Name Level# Lateral Line FLOOR 1 1 FORCE TRANSFER SHEAR WALL w (ft.) 3.0 V Strap Force 1 v' Strap Force 2 SHEAR Net shear to segments, non-adjusted for segment ratio Segment-adjusted shear per NOS 4.3.4 adjusted for overall H/l ratio of Force-Transfer Shear Wall Net shear to segments, non-adjusted per CBC 2306.3 Adjusted shear value per CBC 2306.3 L2 (ft.) 4.0 257 477 330 293 V ,.,._, Total length (ft.) 14 w 114 212 147 130 UPLIFT Uplift E Add. Uplift E Uplift W Add. Uplift W Tot. Uplift E Tot. Uplift W HD# Perforated Length (ft.) 11 plf lbs. plf lbs. Overall H/L Ratio 0.7 Strap Force Shear Use Use# II II 1326 230 1326 230 1 I I I I I I bs. bs. bs. bs. bs. bs. Direction E-W Maximum 477 330 CS16 2 L-13 CK 8/8/2024 Page: lbs. plf strap Shear Wall v • YIL v' • VJl'LIOJ 8fl2 • •V • ....CLllW> • fv'ot..:1) LOVELACE ENGINl=ERING Joa J24015 -MCCULLOCH RESIDENCE SHEETNO. ________ F-_I_ OF ______ _ CALCULATEDBY _______ C_._K_. _ DATE _____ _ STRUCTURAL ENGINEERING SERVICES CHECKEDBY __________ DATE _____ _ 10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121 phone 858.535.9111 • fax 858.535.1989 • www. lovelaceeng.oom SCALE _________________ _ FOUNDATION DESIGN ALLOHABLE BEARIN6 PRESSURE, q= 1500 PSF (PER DESl6N CRITERIA) CONTINUOUS PERIMETER 4 BEARIN6 HALL FOOTIN6S, LOCATION: MAX CONTINUOUS FOOTING H1= MAX LOAD HIDTH REQ'D= (H1/q x 12) = 1e,17f'soo x 12 = 1815 PLF = 15 IN I USE: 15 11 HIDE X 18 11 DEEP HITH 2 # 4 TOP 4 BOTTOM I LOCATION: ___________________ _ H1 = ____________________ = ___ PLF HIDTH REQ'D= (H1 /q x 12) = = IN 1usE, II HIDE X II DEEP HITH TOP 4 BOTTOM I LOCATION: ___________________ _ H 1= = PLF HIDTH REQ'D= (H1/q x 12) = = IN 1usE, II HIDE X II DEEP HITH TOP 4 BOTTOM I ISOLATED SPREAD FOOTIN6S: ( 2-STORY CONT. FTG. POINT LOADS ) MARK, (F-1) P= CONT. FTG. CAPACITY (MIDWALL) Aroq'd = P/q X 144= _5_6_2 .<.L7f's..,._o.,....o<--'-'-X--'l--'4---'4'------------ = 5625 LBS ti If = 540 SQ IN 15<1 USE: 0 PER PAD FOOTIN6 SCHEDULE 15"x36"=540in2 MARK: (F-2) P= CONT. FTG. CAPACITY (ENDWALL) A roq'd = P /q X 144= _3_2-'e,J(,u.5""'0""0'-'X-'--'-14_,_4--'--__________ _ USE: IZI PER PAD FOOTIN6 SCHEDULE MARK, (F-3) = 3281 LBS UJ = 315 SQ IN 15"x21"=315in2 P= 18" x 18" x 18" DEEP PAD FTG. CAPACITY = 3315 LBS = 324 Aroq'd = P/q X 144= 331%;.l.6.L~x,_,_144.!-'--__________ _ SQ IN USE: IZI PER PAD FOOTIN6 SCHEDULE 18"xl8"=324In2 LOVELACE Joa J24015 -MCCULLOGH RESIDENCE SHEET NO f-2 OF -------E CALCULATEDBY _______ G_K __ DATE _____ _ STRUCT URAL ENG I NEERING SERVI CES CHECKED BY __________ DATE _____ _ 10509 Vista Sorrento Parkway, Suite 102, San Diego, CA 92121 phone 858.535.9111 • fax 858.535.1989 • www.lovelaceeng.com SCALE __________________ _ FOUNDATION DESIGN ALLOHABLE BEARIN6 PRESSURE, q= 1500 PSF (PER DESl6N CRITERIA) ISOLA TED SPREAD FOOTIN6S: MARK, (F-4) P= 24" x 24" SQ. PAD FTG. CAPACITY = 6000 LBS A req'd = P/q x 144= 6000 5Q.~x_,___,_14_,._4--'-------------_5_1_6_SQ IN 2411x2411 = 516in2 USE, ~ PER PAD FOOTIN6 SCHEDULE MARK, (f-5) P= 3011 x 30" SQ. PAD FTG. CAPACITY = 9315 LBS A req'd = P/q X 144= q3,71's X 144 = CfOO SQ IN 30"x30"=900in2 --------- USE: ~ PER PAD FOOTIN6 SCHEDULE MARK, (F-b) P= 3611 x 36" SQ. PAD FTG. CAPACITY = 13500 LBS Areq'd = P/q x 144= l350~,.(i""'°""-'-'x_l,_44=---=--________ =_12_6_Cf_SQ IN 3611x3611=1296in2 USE: @J PER PAD FOOTIN6 SCHEDULE MARK: (F-1) P= 42" x 42" SQ. PAD FTG. CAPACITY = 18315 LBS Areq'd = P/q x 144= _,_e3!___,_5,~"'----'-'x,___,__14.,__4.,____ _______ =_11_6_4_SQ IN 4211x4211 = 11641n2 USE: (£] PER PAD FOOT! N6 SCHEDULE MARK, (F-B) P= 48" x 48" SQ. PAD FTG_. _G_A_P_A_G_ITY _____ =_2_4_000LBS A ,ea.'d = P/q x 144= .24000,{5 x 144 = 2304 SQ IN 4811x48"=23041n2 USE, [) PER PAD FOOTI N6 SCHEDULE