Loading...
HomeMy WebLinkAbout2501 STATE ST; ; FPR2022-0023:1Il11Is]I ~' aty of Callsbad Print Date: 07/26/2024 Permit No: FPR2022-0023 Job Address: 2501 STATE ST, CARLSBAD, CA 92008-1624 Status: Closed - Finaled Permit Type: FIRE-Construction Residential Work Class: Multifamily Fire Alarm Parcel U: 1552001000 Track #: Applied: 09/14/2022 Valuation: $0.00 Lot U: Issued: 10/20/2022 Occupancy Group: Project U: Finaled Close Out: 04/17/2024 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check U: INSPECTOR: Salcedo, Felix Plan Check #: Project Title: Description: OCEAN 17 -DIGITAL REVISION TO NEW COMPLETE OPERATING SYSTEM FOR SPRINKLER MONITORING OF NEW 17 UNIT CON[ PROJECT (ADDRESSABLE, NEW CONSTRUCTION, 4-STORIES, 40 DEVICES) (ORIGINAL SUBMITTAL HARD COPIES, REVISION IS DIGITAL E-REVIEW) Applicant: FPContractor: STANDARD ELECTRONICS ACCENT ELECTRONICS JESUS LEDEZMA 613 W MAIN ST 9340 STEVENS RD EL CAJON, CA 92020-3323 SANTEE, CA 92071-2810 (619) 596-9950 (619) 596-9950 FEE AMOUNT FIRE Plan Review (per hr - Regular Office Hours) $240.00 FIRE Sprinkler Monitoring $453.00 Total Fees: $693.00 Total Payments To Date: $693.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov I, Standard Ph: (619) 596.9950 February 25, 2022 Fax: (619) 596-8850 613W. Main . August 23, 2022 El Cajon, CA 92020 Electronics c7, CIO tiC. #590876 BSISACO #AC01903 UL Installer #S3570-1 StandardElectnrnics.us SUBMITTAL SHEET PROJECT: Ocean 17 Condos FA ELEC.CONTR: EQUIPMENT Fire Alarm System ITEM QTY DESCRIPTION MODEL NO. DATA SHEET S3 Addressable Fire Control Panel 1 1 SFM#:7165-1703:0176 SLP-BLK FCI System Sensor Loop Card - 1 loop used for 159 sensors and 159 2 1 modules SFM#:7165-1703:0176 SLC-PM FCI LCD Color Touchscreen display with five programmable switches SFM#7165-1703:0176 LCD-SLP FCI Digital Alarm Communication Transmitter 4 1 SFM#7165-1703:0125 DACT-E3 FCI Cellular Communicator 5 1 SFM#7300-1157:0136 CELLCOMF-LTE DMP 6 2 12 Volt 7 AH Sealed Lead Acid Battery ES7-12 MK Battery 7 1 Fire Alarm Document Storage Box 55U00690 Space Age Analog Photoelectronic Sensor - White 8 SFM#7272-1703:0501 ASDPL3WH FCI Analog Heat Detector ROR 15'/Fixed 135° - White 9 1 SFM#7270-1703-0502 ATD.L3RWH FCI 6" Base, Flanged for use with analog sensor - White 10 4 SFM#7300-1653:0109 B300-6 System Sensor All Weather, Fixed 1350 Heat Detector 11 SFM#7270-0021:0001 302ET 135 FCI Addressable Double Action Pull Station 12 1 SFM#7150-1703:0119 MS7AF FCI Addressable Mini Monitor Module 13 19 SFM#7300-1703:0102 AMM217 FCI Addressable Duct Detector Housing 14 2 SFM#3240- 1653:0209 DNR FCI Analog Photoelectronic Sensor - For DNIRJDNRW 15 2 SFM#7272- 1703:0501 ASDPL3R FCI 3" Sampling Tube for DNR 16 2 (NO DATA SHEET) DST-3 FCI Key Activated Remote Test Station 17 2 SFM# 7300-1653:0212 RTS 15 1KEY System Sensor Addressable Output Relay Control Module 18 8 SFM#7300-1703:0102 AOM2RF FCI Multi-Voltage Relay 19 2 SFM#7300-1004:0101 RIC- 1 Space Age Ph (619)596-9950 February 25, 2022 Standard Fax: (619) 596-8850 613W, Maui . August 23, 2022 I, Electronics El Cajon, CA 92020 C7, C1O LIC. #590876 BSISACO #AC01903 UL Installer #53570-1 StandardElectronics.us SUBMITTAL SHEET PROJECT: Ocean 17 Condos FA ELEC.CONTR: EQUIPMENT Fire Alarm System ITEM QTY DESCRIPTION MODEL NO. DATA SHEET 20 1 Multi-Voltage Relay SFM#7300-1004:0101 RIC-2 Space Age 21 4K 2 conductor, 16 AWG, Unshielded, Jacketed D162F WCW 22 0.3K 2 conductor, 16 AWG, Unshielded, Jacketed, Underground 112+162 RED ADL 23 .1K 4 conductor, 18 AWG, Unshielded, Jacketed 184F ADL 24 .4K 14 AWG THHN SOLID 14 AWG WCW S3 Series Honeywell I Analog and Networking Systems *Gfl S3 Series Control Panel SmaLl Addressable Fire Alarm Control Panel General The Gamewell-FCI®, S3 Series Intelligent Fire Alarm Control Panel provides the latest, innovative high-end processing power. The S3 Series panel is a digital, microprocessor-based system that offers a simple, intuitive solution for the small to mid-sized fire alarm applications. In standalone or network configurations, the S3 Series complies with most fire alarm application requirements. It supports the following types of networks. Up to 64 nodes using the 7100 Series panel. Up to 122 nodes using the S3 Series or E3 Series® panels. Use either twisted-pair wire or fiber-optic to network panels at a high-speed 625K baud ARCNET network bus. With flexible Boolean logic, intelligent detection, and Ethernet connectivity, this system provides power and versatility that surpasses comparable, small addressable fire alarm systems. The basic S3 Series configuration consists of an SLP (Smart Loop Panel) main board, LCD-SLP touchscreen display, SLC loop personality modules, and as seven amp power supply. The SLID main board provides either one or two SLC loops in the Class A or B configuration that supports either of the following protocols: Up to 318 devices per loop using the System Sensor® protocol. If you add a second loop module, it increases the maximum device count to 636 devices. Up to 126 devices per loop using the Apollo protocol. If you add a second loop module, it increases the maximum device count to 252 devices. FEATURES & BENEFITS Listed per ANSI/UL® Standard 864 9th Edition IBC Seismic Certified Allows one SLC loop (expandable to two loops) that supports either System Sensor or Apollo devices in Class A or Class B (Style 4, 6 or 7) Supports a network system of up to 122 nodes (includes E3 Series® panels) or up to 64 nodes (includes 7100 Series) System Sensor supports up to 318 intelligent devices and each SLC Loop supports the following - up to 159 detectors - upto159modu1es (expandable to 636 maximum per panel) Apollo supports up to 126 intelligent detectors and modules per SLC. (Expandable to 252 maximum per panel) Includes a high resolution (4.3") (10.92 cm) color touchscreen display Provides TO amp power supply (120VAC or 24OVAC) Includes four Class Bor two Class A built-in Notification Appliance Circuits (NAC) Provides selectable System Sensor, Cooper-Wheelock, or Gentex strobe synchronization Supports up to 32 serial annunciators (LCD, LED-only, LED Switch) Offers an Ethernet port for programming, a variety of system reports, and a FocalPoint® Graphic Workstation connectivity Provides two fully- programmable Form-C contacts for Fire, Trouble, and Supervisory TimeCap -Saves time and date upto48 hours without any power or battery Automatically adjusts to any NAC End-of- Line Resistor (EOL) value (lk-55k ohm) for Legacy audible/visual appliances Removable display can be used as a remote annunciator Suitable for pre-action deluge applications General Four Class B or two Class A NACs can be wired and synchronized using the System Sensor, Cooper- Wheelock®, or Gentex strobes. To retrofit the SLP on the existing audible/visual appliances, the on-board Electronic EOL (EEOL) automatically adjusts to the EOL resistor in the field. A 4.3 (10.92 cm) color touchscreen display screen shows the following: Events on the system Status of analog addressable devices Complete diagnostic fault codes/messages Five programmable function buttons with LED status for accessibility to the following functions: - Disable/Enable - Trouble Acknowledge - Bypass Output - Alarm Acknowledge - Lamp Test - Custom-defined Application The S3 Series Fire Alarm and Life Safety System is an easy-to-use intelligent fire alarm solution designed for the small to mid-sized buildings. Analog technology delivers the benefits of a simple system installation, while a user-friendly interface makes panel operation and system maintenance quick and intuitive. Smart Panel Programming Using Boolean logic programming, the installer may customize the system to precisely suit the needs of the building owner. Auto-programming allows the installer to instantly locate all the devices on the SLC loop. Simple, Intuitive Display The front panel display provides a user-friendly interface for the operators control. A 4.3" (10.922 cm) color touchscreen displays system status, event details and service modes. On the front of the panel, six LEDs show the following conditions. Fire • Silenced Hazard (Gas or CO) • AC Power Supervisory • Trouble Five custom programmable switches allow the user quick access to common functions specific to the building like device disable, output bypass and device status. Perfect for Retrofits The S3 Series is well-suited for retrofit applications. The SLP provides a simple way to upgrade your fire protection system. It is designed to be an upgrade solution for the legacy FCI, 7100 and Gamewell, 602 Series panels. An added feature is the SLPs EEOL. Using EEOL, the installers can automatically identify the EOL for existing audible/visual appliances. Flexibility for Future Growth The S3 Series can be expanded to add a second SLC loop without replacing the entire system. Using the RPT-E3-UTP Network Repeater, you can network up to 64 nodes (122 nodes with the ANX node expander) using either twisted-pair or fiber-optic. The built-in Ethernet port allows the connection to the Gamewell- FCIs FocalPoint Graphical Workstation. Figure 1 LCD-SLP Display Optional Accessories DACT-E3 - Dialer The Digital Alarm Communication Transmitter sends digital signals over telephone lines to the central station. It connects to the SLID through an RS-485 bus. Using the Contact ID format, the DACT-E3 provides a four-digit account code followed by the code/numbers listed below: Three-digit Event Code Two-digit Group Number Three-digit Contact Number All codes are used to provide specific point identification. The DACT-E3 is compatible with digital alarm communicator receivers (DACRs) that receive the following signaling formats: Contact ID • SIA 3+j. .4+2 For more information, refer to the following data sheets: DACT-E3 Data Sheet, P/N: 9020-0610 RPT-E3-UTP - Network Repeater Card The Network Repeater allows the SLP fire control panels to connect to the broadband network from remote locations. It connects to other networked units using unshielded, twisted-pair wiring. The RPT-E3- UTP is available with two add-on fiber modules: FML-E3 connects to the network using either 62.5/125 micron multi-mode fiber. FSL-E3 connects to the network using 9/125 micron single-mode fiber. Refer to the following data sheets: RPT-E3-UTP Data Sheet, P/N: 9020-0609. FML-E3/FSL-E3 Data Sheet, P/N: 9021-60783 LCD-7100 - Remote Annunciator' . Ordering Information The Remote serial display features an 80-character SLP-BLK: SLP addressable FACP in black S3, SLP-BB display. The LCD-7100 can be surface or flush- enclosure. Requires either an SLC-PM or an SLC95- mounted on a standard 4-gang electrical box. You can PM for SLC loops. use up to five LCD-7100 remote annunciators per SLP SLP-RED: SLP addressable FACP with red door and panel. For more information, refer to the LCD-7100 black S3, SLP-BB backbox. Requires either an SLC-PM Data Sheet, P/N: 9020-0486. or an SLC95-PM for SLC loops. ASM-16 - Addressable Switch/LED Module There are 16 programmable switches available to perform any function the application requires. Each ASM-16 switch has 3 LEDs fully programmable in red, yellow, and green. These LEDs can be programmed to operate with a certain button press or operate independently as a status signal (e.g. ON, OFF, Activated, etc). Up to 16 ASM-16 modules can be connected to the SLP panel. For more information, refer to the ASM-16 Data Sheet, P/N: 9020-0554. ANU-48 -48 LED Driver Unit The ANU-48 provides output for eight remote panel switches and 48 remote LEDs for use in a remotely located UL® Listed annunciator enclosure. Up to 16 ANU-48 modules can be connected to the SLP panel. For more information, referto the ANU-48 Data Sheet, P/N: 9020-0596. Figure 2 illustrates the S3, SLP-BB Cabinet Enclosure. $3, SLP-BB CABINET $3, SLP-BB CABiNET OUTER 000R 20118"H 411TD Figure 2 S3, SLP Enclosure SLP-RED-G: SLP addressable FACP 240VAC power supply with red door and black S3, SLP-BB backbox. Requires either an SLC-PM or an SLC95-PM for SLC loops. SLC-PM: System Sensor Loop Card - 1 loop used for 159 sensors and 159 modules. For use with the S3 panels only. SLC95-PM: Apollo Loop Card-1 loop used for 126 sensors and modules. For use with the S3 panels only. Accessories DACT-E3: Digital Dialer CommunicatorTransmitter for the S3 or E3 Series. LCD-SLP: LCD Color Touchscreen display with five programmable switches. For use with the S3 Series panels. Remote annunciation requires the E3 Series A2 cabinet. (E3BB-BA2, E3BB-RA2) RPT-E3-UTP: Network repeater card with twisted-pair, fiber connections. Requires either an FML-E3 or an FSL-E3 card. FML-E3: Multi-mode fiber-optic card for one channel on the RPT-E3-UTP. FSL-E3: Single-mode fiber-optic card for one channel on the RPT-E3-UTP. SLP-RB: SLP motherboard For use with the replacement or the retrofit solutions. FLPS-7-RB: SLP I20VAC 7A power supply. For use with the replacement or the retrofit solutions. SLP-RETROFIT: SLP Retrofit Kit for the 7100 B-Slim and I F602 panels. Includes the new door and the mounting plate. Requires the following: SLP-RB • FLPS-7-RB SLC95-PM • LCD-SLP SLC-PM S3BB-RB:SLP red cabinet with an inner door for the mounting display behind the locked, plexi-glass door. Requires the following: SLP-RB • FLPS-7-RB SLC95-PM • LCD-SLP SLC-PM LCD-7100: Remote Serial LCD Annunciator ASM-16: Remote Programmable Addressable Switch/ LED Module ANU-48: Remote LED Driver Module Figure 3 illustrates the various S3 Series configuration options that are available. Supports up to 636 Velociti devices or 252 XP95 devices S3 Series ~, R" Fire Al Pane arm D MCS-COF Intelligent Duct 60 Dtector d ,,,, ASD-PL2F ASD-LS Photo Detector Laser Detector I ru Ii Networked up to 122 panels using twisted- pair wire or fiber optics. AMM-21F AMM-211IF Mini Monitor Module Dual lopotlOutpul Module 1 L Li AOM-2RF MS-7AF co c Relay Module Pull Station 41) LCD-7100 LCDSLP LCD-E3 -n RemoteAnnunicator CoTO00o., Annunicator RernoteAnnunicator g . Local E3 Series Energy Trip Panel 07 : 13 Ethernet FocalPoint Workstation ASM-16 ANU-48 Laptop LED Switch Control LED Display Driver Programming Figure 3 S3 Series Panel Configuration Options 4 S3 Series Control Panel Technical Specifications SYSTEM Device Loops: Up to two Class A or B, System Sensor units, each loop supports up to 318 device addresses. OR- Apollo units, each loop supports up to 126 device addresses per loop. NAC Circuits: Four Class B or 2 Class A (2.0 A each circuit), 6.0 A total NAC Operating Voltage: 24 VDC NAC Minimum Voltage: 19.5 VDC @ 20.4 V battery voltage SLC Loop Circuit Operating Voltage: 24 V peak-to-peak Input Voltage: 120 VAC, 60 Hz 240 VAC 50-60 Hz Input Current: 120 VAC, 2.75 amps max. 240 VAC, 1.4 amps max. Aux Power (Resettable): Two Auxiliary circuits, 24 VDC, 1.75 A Aux Power Supervised Class 2 Power-Limited (Non-Resettable): (maximum current of 1.75 is shared between two circuits). Base Panel Current Draw: Standby: 0.111 amps Alarm: 0.243 amps Operating Temperature: 320-120° F (00-490 C) Relative Humidity: 93% (non-condensing) Battery Charger Voltage: +24 VDC Battery Charger Capacity: 55 A/H batteries (cabinet accommodates 12 A/H batteries) Alarm, Trouble & Supervisory Relay Contacts: Form-C, 2 amps ® 24VDC (resistive) Cabinet Dimensions: S3, SLP-BB Dimensions: 14 1/2"Wx20 1/8"Hx4 1/2" 0 (36.83Wx 51.18 H x 11.43 D cm) S3BB-RB Dimensions: 19 3/8"Wx19 3/8"Hx4.5" 0 (49.22 W 49.22 H x 11.43 D) TEMPERATURE AND HUMIDITY RANGES This system meets N FPA requirements for operation at 0— 491C/32 - 120°F and at a relative humidity 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 270C/60 - 80°F STANDARDS The S3 Series Control Panel is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869 FM Approved MEAFDNY. COA 6162 CSFM: 7165-1703:0176 City of Chicago Approved: Class 1 Reference Certificate of Compliance: VMA 45894-02C ISO 9001 Certification For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewelt- fci.com/en-US/ documentation/Pages! Listings.aspx E3 Series", FocalPoint®, Gamewell-FCI®, and System Sensor® are registered trademarks of Honeywell International Inc. Cooper-Wheelock® is a registered trademark of Cooper-Wheelock Corporation. Gentex' is trademark of Gentex Corporation. UL® is a registered trademark of Underwriters Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. For more information Learn more about Gamewell-FCI's S3 Series Control Panel and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com 9021-60730 I H 109/17 6)2017 Honeywell International Inc. Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1703:0176 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: GAMEWELL-FC112 Clintonville Road, Northford, CT 06472 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.branthoneywell.com DESIGN: Model S3 fire alarm control unit. Automatic, manual, waterfiow, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. System components: SLP-E3; Smart Loop Panel Main Board Subassembly LCD-SLP; Liquid Crystal Display- Smart Loop Panel Subassembly FML-E3; Fiber Optic Multi Mode Board FSL-E3; Fiber Optic Single Model Board SLC-PM; Signaling Line Circuit for System Sensor Devices SLC95-PM; Signaling Line Circuit for Apollo Devices SLP-BB; Basic System Enclosure - Backbox, Door, Mounting Plate *DACTE3; Digital Alarm Communication Transmitter *LCDE3; LCD Display *FLPS7RB. Power Supply *RPTE3UpT; Network Repeater *ASM16 PIN 1100-0455; Annunciator Switch *ANU48; P/N 1100-0503; Annunciator *LCD..7100. Remote LCD Display. Refer to the listee's data sheet for additional detailed product description and operational considerations RATING: 120 V, 60 Hz, 2.75 A 240 V, 50/60 Hz, 1.4 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. *Rev 08-30-17 gt r This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division -PM SLC- Honeywell alog and Networking Systems SLC Personality Loop Modules General The Gamewell-FC15, S3 Series (SmallAddressable Fire Alarm Control Panel) signaling line circuits (SLCs) provide the communication between the S3 Series fire alarm control panel and the SLC devices. Each SLP-E3 (Smart Loop Panel) main board supports either one or two of the following plug-in SLC-Personality Modules. SLC-PM (Signaling Line Circuit Personality Module) SLC95-PM (Signaling Line Circuit-95-Personality Module) The SLC-PM/SLC95-PM modules provide one SLC loop in Class B or Class A wiring. The SLC-PM supports the following devices: Up to 318 System Sensor Velociti® devices. - 159 sensors and 159 modules Up to 198 System Sensor CLIP devices. - 99 sensors and 99 modules The SLC95-PM supports the following devices: Up to 126 Apollo XP95 devices. - 126 sensors and modules Installation The SLC-PM/SLC95-PM modules are designed to be plugged into the Smart Loop Panel-Main Board (SLP-E3). This feature allows you to expand the S3 Series (Small Addressable Fire Alarm Control System without the need to remove or replace hardware. Ordering Information SLC-PM: System Sensor, Signaling Line Circuit-Personality Module with up to 318 devices SLC95-PM: Apollo SLC Personality Module with up to 126 devices FEATURES & BENEFITS SLC95-PM (Apollo) Listed perANSl/UL • SLC-PM supports the SLC95-PM supports the Standard 864 9th System Sensor Velociti Apollo XP95 protocol Edition protocol using up to using up to 126 devices 318 devices - Uses up to 126 - Uses up to 159 sensors and modules sensors and 159 modules Supports Class Aor Class B Wiring Offers a simple, plug-in installation feature SLC-PM/SLC95-PM Technical Specifications SYSTEM STANDARDS For a complete listing of all SLC-PM SLC95-PM Operating Current: 0.014 amp 0.016 amp The SLC-PM/SLC95-PM are designed to comply compliance approvals and certifications, please visit: Alarm Current: 0.014 amp 0.016 amp with the following standard: http://www.gamewell- Line Impedance: 40 Ohms UL Standard: UL 864 9th Edition fci.com/en-US! Line Capacitance: 0.5 uf max. AGENCY LISTINGS AND APPROVALS documentation/Pages! Listings.aspx Operating Voltage: 24 VDC FWR Operating Temperature: 321 to 1200 F (00 to 49° C) These listings and approvals apply to the modules Velociti® and Gamewell-FCI° Relative Humidity: 0 to 93°/o,non-condensing at specified in this document. In some cases, certain are registered trademarks of 90° F (32° C) modules or applications may not be listed by certain Honeywell International Inc. approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL® is a registered trademark TEMPERATURE AND HUMIDITY RANGES of Underwriters Laboratories UL Listed: S1869 Inc. This system meets NFPA requirements for operation at 0 FM Approved - 49°C/32 - 120°F and at a relative humidity 93% ± 2°/c MEA FDNY: COA #6162 This document is not intended RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F to be used for installation). However, the useful life of the systems standby batteries CSFM: 7165-1703:0176 purposes. We try to keep our and the electronic components maybe adversely affected City of Chicago Approved: Class 1 product information up-to- by extreme temperature ranges and humidity. Therefore, it Reference Certificate of Compliance: VMA 45894-02C date and accurate. We cannot cover is recommended that this system and its peripherals be ISO 9001 Certification all specific applications or anticipate all requirements. installed in an environment with a normal room All specifications are subjectto temperature of 15— 271C/60 - 80°F change without notice For more information Learn more about Gamewell-FCI's SLC-PM/SLC95-PM and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 9021-60781 I E 109/17 Honeywell www.honeywell.com 52017 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1703:0176 Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Model S3 fire alarm control unit. Automatic, manual, waterfiow, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. System components: SLP-E3; Smart Loop Panel Main Board Subassembly LCD-SLP; Liquid Crystal Display- Smart Loop Panel Subassembly FML-E3; Fiber Optic Multi Mode Board FSL-E3; Fiber Optic Single Model Board SLC-PM; Signaling Line Circuit for System Sensor Devices SLC95-PM; Signaling Line Circuit for Apollo Devices SLP-BB; Basic System Enclosure - Backbox, Door, Mounting Plate *DACTE3; Digital Alarm Communication Transmitter *LCDE3; LCD Display *FLPS7RB; Power Supply *RPTE3UPT; Network Repeater *ASM16 P/N i 100-0455; Annunciator Switch *ANU48; P/N 1100-0503; Annunciator *LCD.7100. Remote LCD Display. Refer to the listee's data sheet for additional detailed product description and operational considerations RATING: 120 V, 60 Hz, 2.75 A 240 V, 50/60 Hz, 1.4 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. Rev 08-30-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division LCD-SLP Honeywell LCD-SLP Analog and Networking Systems LCD Touchscreen Annunciator Display General The Gamewell-FCI, Liquid Crystal Display, Smart Loop Panel (LCD-SLP) is a touchscreen annunciator display used with the S3 Series and E3 Series® Systems. The LCD-SLP provides an easy-to-use, intuitive interface for the operator's control. The 4.3" (10.92 cm) color touchscreen display shows the following: System Status • Event Details • Service Modes The following identify the LED Indicators that display on the panel. AC (green) • Fire Alarm (red) • Hazard (blue) Supervisory (yellow) • Trouble (yellow) • Silenced (yellow) The five fully-programmable front panel switch/LED combinations provide a direct access to perform the following tasks: Device Bypass • Lamp Test • Enable/Disable Groups or Devices The display features the following physical switches. Menu • System Reset • Drift Walk Test Five Programmable Switches Installation The LCD-SLP panel's adaptable design allows it to be mounted in a variety of S3 Series, E3® Series or Retrofit cabinet installations. For additional information, refer to the E3 Series Cabinets Data Sheet, P/N:9020-0649. S3 Series Cabinets - SLP-BB basic system enclosure - S3BB-BB/S3BB-RB system enclosure E3 Series® Cabinets - AA size cabinet (E3BB-BAA, E3BB-RAA) - A2 size cabinet (E3BB-B42, E3BB-RA2) - A size flush cabinet (E3BB-FLUSH-LCD) - B-Slim cabinet (E3BB-RBSLIM) - B size cabinet (E3BB-BB, E3BB-RB) - C size cabinet (E3BB-BC/INCC, E3BB-RC/INCC) - D size cabinet (E3BB-BD/INCC, E3BB-RD/INCC) Retrofit Cabinets - 600-RETROFIT - 7200-B-RETROFIT - 7200-C-RETROFIT Ordering Information LCD-SLP: LCD Touchscreen display unit E311313-BA2: Remote enclosure with inner door, black, one LCD slot E311313-RA2: Remote enclosure with inner door, red, one LCD slot E313113-FLUSH-LCD: Remote flush mounting enclosure, black, LCD slot FEATURES & BENEFITS Listed per ANSI/UL Standard 864 9th Edi- tion UL Listed and FM approved for Pre- Action/Deluge and Agent Releasing Provides 43(10.92cm) color touchscreen dis- play of System Events Includes five custom function buttons with LEDs for direct access to system controls. Shows the Hazard LED to indicate gas, carbon monoxide or other toxic gases Both the E3 Series (ILl- MB-E3/ILl95-MB-E3) and the S3 Series (SLP) support up to 15 LCD- SLP displays via the PS- 485 serial interface Offers the following installation options: - Locally mounted in the E3 Series and S3 Series panels - Remotely mounted in the E3 Series, A2 cabinet - LCD Flush enclosure Displays the following six LED indicators: -AC Power - Alarm - Hazard - NAC Silence - Supervisory - Trouble LCD-SLP Technicat. Specifications SPECIFICATIONS Operating Voltage: 24 VDC FWR Operating Current: 0.030 amp Alarm Current: 0.065 amp Operating Temperature: 32°to120° F (00to49° C) Relative Humidity: 0 to 93°/o non-condensing at 900 F (32° C) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at - 49°C/32 - 120°F and at a relative humidity 93% ± 2°/c RH (non-condensing) at 32°C ± 2°C (90°F ± 31F). However, the useful life of the systems standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 27°C/60 - 80°F. STANDARDS The LCD-SLP is designed to comply with the following standard: UL Standard: UL 864 9th Edition: AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869 FM Approved MEAFDNY: COA#6162 CSFM: 7165-1703:0176 City of Chicago Approved: Class 1 Reference Certificate of Compliance: VMA 45894-02C ISO 9001 Certification For a complete listing of all compliance approvals and certifications, please visit http:/!www.gamewetl- fci.com/en-IJS/ documentation/Pages! Listings.aspx E3 Series® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information Learn more about Gamewell-FCI's LCD-SLP and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com 9021-60782 I F 109/17 @2017 Honeywell International Inc. Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1703:0176 Page 1 of 1 CATEGORY: 7165 -.FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: GAMEWELL-FC112 Clintonville Road, Northford, CT 06472 Contact: Lisa Brant (203)484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Model S3 fire alarm control unit. Automatic, manual, waterfiow, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. System components: SLP-E3; Smart Loop Panel Main Board Subassembly LCD-SLP; Liquid Crystal Display- Smart Loop Panel Subassembly FML-E3; Fiber Optic Multi Mode Board FSL-E3; Fiber Optic Single Model Board SLC-PM; Signaling Line Circuit for System Sensor Devices SLC95-PM; Signaling Line Circuit for Apollo Devices SLP-BB; Basic System Enclosure - Backbox, Door, Mounting Plate *DACT.E3. Digital Alarm Communication Transmitter *LCDE3; LCD Display *FLPS..7..RB. Power Supply *RpT..E3.UpT; Network Repeater *ASM16 P/N i 100-0455; Annunciator Switch *ANU48; P/N 1100-0503; Annunciator *LCD..7100; Remote LCD Display. Refer to the listee's data sheet for additional detailed product description and operational considerations RATING: 120 V, 60 Hz, 2.75 A 240 V, 50/60 Hz, 1.4 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. *Rev 08-30-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILL.O,, M.E., F.P.E. Fire Engineering Division DACT-E3 Features Listed under UL® Standard 864, 9th Edition Communicates with the E3, ILI-MB-E3/lL195-MB-E3 sub-assembly via RS-485 Communicates in a variety of formats (including full Contact ID) Transmits and verifies data to the central station Offers pre-programmed dialing to the central station phone number Performs on and off-hook status to the phone lines Traces proper central station ACK" and "Kiss-off' tone Activates hang-up and release phone lines Compatible with the IPDACT Internet Communicator GameweII - FIRE CONTROL INSTRUMB.ITS BACTmE3 by Honeywell Description Digital Alarm The Digital Alarm Communicator Transmitter (DACT-E3) is Communicator Transmitter an optional component of the E3 Series® Expandable Emergency Evacuation System. The DACT-E3 sends digi- tal signals over the telephone network to a central station. This module can be located in the main cabinet or remotely located via a local RS-485 serial interface. The DACT-E3 is compatible with digital alarm communica- tor receivers (DACRs) that receive the following signaling formats: SIA DC8 • 3+1 2300 Hz SIA DCS20 • 4+2 1400 Hz Ademco Contact ID • 4+2 2300 Hz 3+1 1400 Hz In addition to the DACT-E3 being compatible with digital signaling formats, the DACT-E3 features numerous for- mats for communication to a central station. As a digital communicator, the DACT-E3 complies with FCC Part 8, Telecommunication Standards for DC and AC Ringer Equivalence. Installation Instructions The DACT-E3 is adaptable for installation in standard E3 Series® System cabinets. Typically, the DACT-E3 module mounts on standoffs on top of the left side of the ILl-MB- E3/IL195-MB-E3 module. Either unit can be easily con- nected to the backbox or sub-assembly plate depending on the cabinet module. Note: For instructions on installing the DACT-E3, refer to the E3 Series® Expandable Emergency Evacuation Instal- lation/Operation Manual, Part Number: 9020-0574 or the DACT-E3 Installation Instructions Part Number:9000-0581. Specifications Operating Voltage: 24 VDC (from the PM-9/PM-9G power supply) Operating Current: 0.018 amp Alarm Current: 0.018 amp Operating Temperature: 32° to 120° F (0 to 49° C) Relative Humidity: 0 to 93%, non-condensing at 90° F (32° C) E3 Series® and NetSOLO® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Ordering Information An ISO 9001-2000 Company SIGNAUNG f QCity MEA fgo City of LISTED oppaovno Approved App.ee S1869 3025415 FDNY: 7165.1703:0125 CO-' Approved C0A66077 CIan2 Part Number Description DACT-E3 Digital alarm communicator transmitter GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell.FCI for their use. @2011 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0610 Rev. I page 1 of 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 9 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1703:0125 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: GAMEWELL-FC112 Clintonville Road, Northford, CT 06472 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: Iisa.brant©honeywell.com DESIGN: Model E3 Series® BROADBAND and E3 Series® CLASSIC Voice Evacuation System. The E3 Systems may also work in conjunction with all the sub-assemblies of listee's 7100 Series Control Panel and NetSOLO systems (CSFM Listing No. 7165-1703:0105 and 6911-1703:0116, and 6911-1703:0118). Unit conveys all fire alarm, audio evacuation, voice paging, and fire fighter communications. Power-limited; non-coded, automatic, manual, smoke control, water flow, sprinkler supervisory, local auxiliary, central station, remote station, and proprietary service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: ILI-MB-E3; Intelligent Loop Interface Master Board PM-9, PM-9G; Power Supply ILI-95-MB-E3, ILI-95-S-E3; Loop Interface Subassemblies E3BB-FLUSH-LCD; Enclosure for ICD-E3 E3BB-BA/-RA/-BAA/-RAA/-BB/-RB/-BC/-RC/-BD; Cabinets RPT-E3-FO; or Repeater Sub-assembly, Fiber Optic or RPT-E3-UTP; Repeater Sub-assembly, Unshielded twisted pair wire LCD-E3; LCD Keypad Display *LCDSLP; LCD Touchscreen Display Screen DACT-E3 sub-assembly; Digital alarm communicator transmitter ILI-S-E3; Intelligent Loop Unit, Expansion Board ANX-SR, ANX-MR-FO, ANX-MR-UTR; Addressable Node Expanders Sub Assembly INCC-E; Intelligent Network Enclosure INCC; Intelligent Network Central Command INI-VG, INI-VGC-UTP, INI-VGC-FO, INI-VGX-UTP; Intelligent Network Interface Sub Assembly INI-VGX-FO, I NI-VGE-UTP, INI-VGE-FO; Intelligent Network Interface Sub Assembly ASM-16; Annunciator Switch Sub Assembly INX; Network Audio Transponder Enclosure ANU-48; Annunciator Sub Assembly NGA; Touch Screen LCD Display Sub Assembly LCD-7100; Remote LCD Display SBB-C4, SBB-D4; Backbox *Revision 09-18-20 \'lMN This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Listing No. 7165-1703:0125 Page 2 of 2 FCI-VDR-D4B, FCI-DR-C413, FCI-CR-D4B; Doors with locks AA-100, AA-120; Amplifiers AM-50-25, AM-50-70; Amplifier Sub Assembly CHGI20; Battery Charger with Cabinet BC-IIFCI-LBB; Backbox IPDACT-2; IP Digital Alarm Communicator FPJ; Firefighters's Telephone Jack Receptacle FHS; Portable Firefighters's Telephone Handset 7100 Series#; Fire Alarm Control Panel or INI-7100 UTP#; Intelligent Network Interface Sub-assembly, [Twisted, unshielded wire] or lNl-7100 FO#; Intelligent Network Interface RATING: 120 V, 60 Hz, 3.5 A Primary; 24 V dc, 9A Secondary INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as fire alarm control unit for use with separately listed electrically and functionally compatible initiating and indicating devices. Suitable for high-rise applications when used with the above voice evacuation systems. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NPFA 72. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of alarm signaling), the Retard/Reset/Restart period shall be 30 seconds or less. *Revision 09-18-20 WAN r, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division DMP.COM 0 0 0 0 0 0 @DMPALARMS CeliCom LIE Alarm Communicators FEATURES Fully supervised universal alarm communication over LIE Program your own account number to easily work around locked panels External SMA antenna Use Contact ID dialer capture, four input zones or bell monitoring Wiring for Ademco ECP Bus Communicates with DMP SCS-1R and SCS-VR Receivers Armed/disarmed status LED Private labeling available on the rubber logo insert Two output terminals with multiple output options WORKS WITH MOST PANELS If the existing panel supports Contact ID, then it's a candidate for upgrading with CellCom-LTE-V, CellComZ-LTE-V, or CellComF-LTE-V. There are no issues with lockout codes. Simply add the CellCom-LTE-V unit to the existing installation and program in your own account number. AVAILABLE BURGLARY COMMUNICATION The CellCom-LTE-V provides control of basic panel security functions and video. The CelIComZ-LTE-V adds the ability to remotely interact with Z-Wave devices, enabling a variety of home automation features including control of lights, door locks, thermostats, and more. FIRE COMMUNICATION The CellComF-LTE-V offers cellular fire communication on any fire control panel via Contact ID captures or zone inputs. Meets NFPA 72 Standard for Single Communication Technology. MOBILE SYSTEM CONTROL With CellComLTE communicators, you can easily update your customers' older residential and commercial systems to the latest cellular communication links. With cellular in place, end users can remotely access their panels via the Virtual Keypad app. This makes it possible to use their mobile device not only to control basic arm/disarm functions and receive alerts, but also to control Z-Wave home automation devices. ENABLE VIDEO ON THE APP With the CellCom-LTE-V communicators, you can easily add up to six video cameras. Via the Virtual Keypad app, end users can remotely view their premises to cancel or verify an alarm or simply check in on children or senior adults. Users can also capture still or video images. FULLY SUPERVISED COMMUNICATION CellCom-LTE-V allows alarm messages to be communicated to an SCS-1R or SCS-VR Receiver over the Verizon LTE network. Sending alarm communication for burglary control panels over the LTE network provides higher speeds. FIELD PANEL UPDATES The Model 400 USB Flash Module allows you to easily field update firmware for panels that would otherwise require the use of a computer and a Model 399 Programming Harness. SYSTEM PROGRAMMING System programming over cell via VirtualLink includes zone information and monitoring center communications. MULTIPLE CONNECTION OPTIONS CellCom-LTE-V communicators can be attached to the existing panel in a variety of ways. It can capture Contact ID messages from the dialer or connect the four input zones from outputs on the panel. Or it can sense the output of the bell of an existing alarm and communicate the appropriate message to the central station. FOUR ZONES Each of the CellCom-LTE-V models provide four zones for connection to burglary control panel outputs. Zone 4 is intended for connection to the control panel bell output. OUTPUTS Use outputs to connect to an arming zone of an existing panel for control of that panel via the app. EASY UPGRADE FOR DIALER-ONLY PANELS Older, dial-up panels have new life with the addition of cellular communication. Earn customer loyalty by extending the life of their existing panels and build satisfaction with the purchase decision. BUILD CUSTOMER LOYALTY Avoid the possibility of customers seeking mobile intrusion alarm features from a competitor by enabling those features on their existing panel with a minimal additional cost. They are less likely to switch systems and cancel their contract. When the time does come to replace the panel, they are more likely to rely on you. DMP's Virtual Keypad app can be branded with your organization's logo and contact information to provide a daily reminder of your services. CELLCOM SERIES Specifications Dimensions 5.5W 3.75 H xl D Color White Open-Collector Outputs 2 Zones 4 CellCom-LTE-V Primary Power 12VDC Current Draw Alarm 99 mA Standby 51 mA CeIIComF-LTE-V Primary Power 12-24VDC Current Draw at 12VDC Alarm 99 mA Standby 51 mA Current Draw at 24VDC Alarm 81 mA Standby 30 mA CeIIComZ-LTE-V Primary Power 12VDC Current Draw Alarm 109 mA Standby 64 mA Ordering Information CellCom-LTE-V Universal Alarm Communicator CellComF-LTE-V Universal Fire Alarm Communicator CellComZ-I.TE-V Universal Alarm Communicator with 2-Wave Certifications California State Fire Marshal (CSFM) Underwriters Laboratory (UL) Listed ANSl/UL 1610 Central Station Burglar (Cellular) ANSI/UL 1023 Household Burglar ANSVUL 985 Household Fire Warning (CID Capture) ANSI/UL 864 Fire Protective Signaling Systems Cellular FCC Part 15: MlVCNN0301 CellComLTE FCC Part 1510: CCKPCO163 IC: 5251A-PC0163 800-641-4282 I DMP.coni 2500 N. Partnership Bind, Springfield, MO 65803 Designed, Engineered & Manufactured in Springfield, MO using U.S. & global components 52018 Digital Monitoring Products, Inc. I 11-1774 118345 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1157:0136 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Monitoring Products, lnc.2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Amy Konwinski (417) 831-9362 Fax (417) 447-9698 Email: akonwinski@dmp.com DESIGN: Models CellComSLC, CellComSLCZ, CellComSLCF, CellCom-LTE-V, CellComZ-LTE-V, CellComF-LTE-V, iComSLF, iCOMSL, iComSLZ, DualComNF-L, CellComSF, CellComDF, and *DualComNF FN Communicators. Refer to listee's data sheet for additional detailed product description and operational considerations and listee's installation instructions for details. RATING: 12 VDC or 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as alarm communicators for use with separately listed fire and burglary alarm control units. For indoor use only. *Models CellComSLCF, CellComF-LTE-V, DualComNF-L, CellComSF, CellComDF, and DualComNF-FN comply with the applicable requirements in UL 864, 10th Edition. *Models iComSLF, iCOMSL, iComSLZ comply with the applicable requirements in UL 864, 9th Edition. *Models CellComSLC, CellComSLCZ, CellCom-LTE-V, CellComZ-LTE-V comply with the applicable requirements in UL 985, 5th Edition. Refer to listee's Installation Instruction Manual for details. Burglary and other non-fire functions were not examined. *Rev 05-26-22 DAL This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division O I 11 00 09'___I 6521(2.5820.04) 1510(5.9420.04) m 1 I 0B °CE ( 70BT25505 SPECIFICATIONS Nominal Voltage (V) 12V Nominal Capacity 20 hour rate ( 0.36A to 10.50V) 7.2Ah 10 hour rate ( 0.72A to 10.50V) 6.84Ah 5 hour rate (1.22A to 10.20V) 6.12Ah 1 C (7.2A to 9.60V) 3.24Ah 3C (21.6A to 9.60V) 2.52Ah Weight Approx. 5.39Lbs. (2.45kg) Internal Resistance (at 1KHz) 22 mQ Maximum Discharge Current for 30 seconds: 144A Maximum Discharge Current for 5 seconds: 288A Operating Temperature Range Charge 0°C (32°F) to 40°C (104°F) Discharge -15°C ( 5°F) to 50°C (122°F) Storage -15°C (5°F) to 40°C (104°F) Charge Retention (shelf life) at 20°C ( 68°F) 1 month 92% 3 months 90% 6 months 80% Charging Methods at 20°C ( 68°F) Cycle Use : Charging Voltage 14.4 to 15.OV Maximum Charging Current : 2.16A Standby Use : Float Charging Voltage 13.50 to 13.80V Life expectancy: Cycle Use : 100% depth of discharge 200 cycles 80% depth of discharge 225 cycles 50% depth of discharge 500 cycles Standby Use : 3-5 years Case Material : ABS (Option : 94-HB & 94V-0 Flame Retardant Case Material) Terminal Fl or F2 Maintenance-Free Rechargeable Sealed Lead-Acid Battery DIMENSIONS mm(inch) 'k, w F1 F2 (FABTON TAB NO. 107) (F021504 TAB NO. 250) MK Battery 1631 South Sinclair Street • Anaheim, California 92806 Toll Free: 800-372-9253 • Fax: 714-937-0818 • E-mail: sales@mkbattery.com 0 4, Standard Features: Installed with a 4 GB digital flash drive with USB B connector 2 key ring hooks to hold system keys Business card holder for key contacts Overall dimensions are 12" x 13" tall and 2 1/4" deep 18 gauge steel box and cover for security Durable powder coat baked on finish other colors available Standard 3/4" cat 30 key lock. Other lock assemblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "SYSTEM RECORD DOCUMENTS" Legend sheet for documentation, passwords and system information SYSTEM RECORD DOCUMENTS The SRD is the perfect item to help you meet demanding code requirements today. NFPA 722013 7.7.2.4 states that a cabinet must be "prominently labelled 'SYSTEM RECORD The SRD is the perfect fit to meet todays demanding code requirements. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2013 7.7.2.1 states, "With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the software not being on site when technicians arrive to service the system. Along with your fire alarm software you can store your test & inspection, service records, manuals & system records. Using a standard USB B connector you may also store you records electronically (See NFPA 72 2013 7.5.6.7). The SRD has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has an organized record for identifying equipment information, required documentation locations (See NFPA 72 2013 7.2.1). ISO qpp-ir' 7AA7A ronics, Inc. ll Free MEYAEMt cal Made In\U.S.A. ..ax Space Age Electronics, Inc. 2013 ED0584 LT10641 Rev.A 1/2 No Excuses, Just Solutions! mentation (SIG-FUN) -rn- kd m c. 3 LT10644 R3. I system information -off, maintenance & ernate locations JOSPACEAGE ELECTRONICS, INC. Specifications: The system record documents box (SRD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "SYSTEM RECORD DOCUMENTS "with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The SRD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holder with a location to mount standard business type cards for key contact personnel. Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! Ordering Information: ,,,.Part # Description SSU00689 System Record Documents Cabinet RED SSU00690 Custom screening with your Logo EA0315 10 pack door legend sheet This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0584 LT10641 Rev.A 2/2 Honeywell Addressable Devices Gaieel Velociti® Series 3 Detectors Photoelectric Detectors Description The Gamewell-FCI, Velociti® Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern bright white color, the Velociti Series 3 is aesthetically pleasing for today's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations. The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI, ASD-PL3 photoelectric detectors re-designed optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment. The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR (DNRW) duct smoke detector housing. The ASD-PTL3 multi- sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 135°F fixed temperature thermal sensing. For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number after the detector model. Note: Although the E3 Series® and S3 Series panels support both the Velociti® and CLIP protocols, the GWF-7075 panel does not support the CLIP protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. Photoelectric Detector FEATURES & BENEFITS Complies with UL® Standard 268 7th Edition Designed with anew profile to offer modern and improved aesthetics Contains a built-in functional test switch activated by external magnet Supports a low standby current Provides rota ryaddress switches (01-159) Supplies optional relay, isolator, or sounder bases (standard or tow frequency) Includes dual LEDs for • Offers expanded color 3601 visibility options Ordering Information NOTE: -IV suffix indes Ivory color model. NOTE:'-BL: sZfirticates Black color model. NOTE: "WH" suffix mdi ight White color model. ASO-PL3: oelectric smoke detector, bright white, Velociti ASD-PL3R: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, bright white, Velociti ASD-PTL3: Photoelectric smoke detector with thermal sensing, bright white, Velociti ASD-PL3-IV: Photoelectric smoke detector, ivory, Velociti/ CLIP ASD-PL3R-IV: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, ivory, Velociti/CLIP ASD-PTL3-IV: Photoelectric smoke detector with thermal sensing, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540. Note: "IV" suffix indicates Flashscan and CLIP devices. "WH" suffix indicates bright white B501-WHITE: 4" Flangeless mounting base, bright white B501-WHITE-BP: 4" Flangeless mounting base bulk pack, bright white B501-IV: 4" Flangeless mounting base, ivory B300-6: 6° Flanged mounting base, bright white B300-6-IV: 6" Flanged mounting base, ivory B300-6-BP: 6" Flanged mounting base bulk (Pack of 10) B200SR-WH: Standard sounder base, bright white B200SR-IV: Standard sounder base, ivory B200S-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B200S-LF-WH: Intelligent addressable low frequency sounder base, bright white 8200S-LF-IV: Intelligent addressable lowfrequency sounder base, ivory B224RB_WH: Relay base, bright white B224RB-IV: Relay base, ivory B224B1-WH: Isolator base, bright white B224B1-IV: Isolator base, ivory DNR: Intelligent duct detector housing, non-relay DNRW: Intelligent duct detector housing, non-relay, watertight 2 Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6" Base, bright white TR300-IV: Accessory Flange Ring for B300 6" Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single-gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-IR: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCSCOF Series detectors. (Pack of 10) CK300-BL: Black detector kit. (Pack of 10) CK300-IR-BL: Black, detector color kit for use with MCSCOF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/ or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole for XR2B. Shipped with three, 5-foot (1.524,m) sections. Velociti® Series 3 Detectors Technicat. Specifications SYSTEMS Photoelectric Intelligent Detector: Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.49 cm) installed in B300-6 base 4 inches (10.16 cm) installed in B501 base Shipping Weight: 3.4 oz (96.4 g) Operating Temperature Range: Photo: 32° F to 122° F (0° C to 5010 Photo in Duct Applications: -4° Fto 158° F (-20° C to 70° C) Photo with Thermal: 32° F to 100° F (0° C to 38° C) Operating Humidity Range: 100/6 to 93% non-condensing Rate-of-Rise Detection: Responds to greater than 151F/minute or 135°F (8.3° C/minute or 57°C Air Velocity Range: 0 to 4,000 ft/mm (0 to 1219.2 m/min) Electrical Specifications Voltage Range: 15 to 32 VDC Standby Current (® 24 VDC): 200 UA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.): 2 mA® 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.): 4.5 mA® 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 STANDARDS The Velociti® Series 3 Photoelectric Detectors are designed to comply with the following standard: UL Standard: UL 268 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2332 FM: 3023594 MEA FDNY: COA-219-02-E Vol. VI CSFM: 7272-1703:0501 ISO 9001 Certification For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages! Listings.aspx [3 Series®, Velociti® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. For more information Learn more about Gamewell-FCI's Velociti® Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com 9020-0617 I K 04/2018 02018 Honeywell International Inc. Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 9 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1703:0501 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: GAMEWELL-FCI12 C)Efitonville Road, Northford, CT 06472 Contact: Lisa Bran03) 484-6105 Fax (203) 484-7309 Email: lisa.bran1honeywell.com DESIGN: Models ASD-PL3, ASD-PL3R, and ASD-PTL3 analog addressable, photoelectric smoke detectors for open area and duct installations. Model ASD-PTL3 has a complementary heat detector. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed System Sensor base Models *13501 *B21OLP (CSFM,Listing 7300-1653:0109), B200S and B200SR (CSFM Listing 7300-1653:0213), B200S-LF and B200SR-LF (CSFM Listing 7300-1653:0238), B300-6 and B300-6-IS bases (CSFM Listing 7300-1653:0109), *B224Bl and *B224RB (CSFM Listing 7300-1653:0126), System Sensor duct detector housings Models DNR and DNRW (CSFM listing 3240-1653:0209) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. *All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition, January 11, 2016. XLF: 7272-0028:0503 *Revision 12/17/19 DCC This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Honeywell I Addressable Devices Velociti® Series 3 Detectors Thermal Detectors Description The Gamewell-FCI, Velociti® Series 3 intelligent thermal detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern bright white color, the Velociti Series 3 is aesthetically pleasing for today's contemporary buildings. The Velociti Series 3 heat detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations. The thermal detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. Velociti Series 3 thermal detectors provide cost-effective, intelligent property protection using the following single thermistor: ATD-L3 offers 135°F fixed thermal detection. ATD-L3R offers 135°F fixed and rate-of-rise thermal detection. ATD-L3H provides fixed high-temperature detection at 190°F. For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number that appears after the detector model. Note: The E3 Series® and S3 Series panels support both the Velociti® and CLIP protocols, and the GWF-7075 panel supports only the Velociti® protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS Complies with UL®268 Contains a built-in Provides rotaryaddress 7th Edition functional test switch switches (01-159) Designed with a new activated by an Supplies optional relay, profile to offer modern external magnet isolator, or sounder and improved Supports a lowstandby bases (standard or low aesthetics current frequency) Thermal Detector Includes dual LEDs • Offers expanded color used for 3601 visibility options Ordering Information NOTE: -IV suffix indic-1vory color model. NOTE: "-BL" s, ffi 4rr icates Black color model. NOTE: "WH"ffix indicates Bright White color model. ATD-L3: Thermal heat detector, 135°F fixed, bright white, Velociti ATD-L3-IV: Thermal heat d , 35°F fixed, ivory, Velociti/CLIP ATD-L3 ermal heat detector, 135°F rate of rise, bright white, Velociti ATD-L3R-IV: Thermal heat detector, 135°F rate of rise, ivory, Velociti/CLIP ATD-L3H: Thermal heat detector, 190°F high temp, bright white, Velociti ATD-L3H-IV: Thermal heat detector, 190°F high temp, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540. 8501-White: 4" Flangeless mounting base, bright white B501-White-BP: 4" Flangetess mounting base bulk pack, bright white B501-IV: 4" Flangeless mounting base, ivory B501-BL 4" Flangeless mounting base, B300-6:6' Flanged mounting base, bright white B300-6-IV: 6" Flanged mounting base, ivory 8300-6-BP: 6" Flanged mounting base bulk pack B200SR-WH: Standard sounder base, bright white B200SR-IV: Standard sounder base, ivory B200S-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, bright white 8200SR-LF-IV: Standard low frequency sounder base, ivory 8200S-LF-WH: Intelligent addressable low frequency sounder base, bright white B200S-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224R8-IV: Relay base, ivory B22481-WH: Isolator base, bright white B22481-IV: Isolator base, ivory Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6" Base, bright white TR300-IV: Accessory Flange Ring for B300 6" Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single-gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-IR: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCS- COF Series detectors. (Pack of 10) CK300-BL: Black detector kit (Pack of 10) CK300-IR-81: Black, detector color kit for use with MCS- COF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/or removal of the detector heads from the bases in high ceiling applications. XP-A: Extension pole for XR213. Shipped with three, 5- foot (1.524,m) sections. VeLociti® Series 3 Detectors Technical Specifications SYSTEMS Thermal Intelligent Detector Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.6 cm) installed in B300-6 base 4 inches (10.2 cm) installed in 6501 base Shipping Weight: 3.4 oz (95 g) Operating Temperature Range: Thermal 135° F fixed: -4° F to 100° F (-20° C to 38° C) Thermal 135° F rate-of-rise: -4° F to 100° F (-20° C to 38° C) Thermal 1901 F rate-of -rise:-4° Fto 135° F (-20° C to 57° C) Operating Humidity Range: 10% to 93% non- condensing Rate-of-Rise Detection:: Responds to greater than 151F/minute or 135°F (8.3° C/minute or 57°C Electrical Specifications Voltage Range:: 15 to 32 VDC Standby Current (® 24 VDC): 200 uA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.): :2 mA® 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.): :4.5 mA® 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating: :0.0063 STANDARDS For a complete listing of all compliance approvals and The Velociti°' Series 3 Thermal Detectors are designed to certifications, please visit: comply with the following standard: http://www.gamewell- UL Standard: UL 268 fci.com/en-US/ documentation/Pages! AGENCY LISTINGS AND APPROVALS Listings.aspx These listings and approvals apply to the modules E3 Series, Velociti® and specified in this document. In some cases, certain Gamewell-FC16 are registered modules or applications may not be listed by certain trademarks and CLIP is a approval agencies, or listing may be in process. trademark of Honeywell Consult factory for latest listing status. International Inc. UL: S2332 UL® is a registered trademark FM: 3023594 of Underwriter's Laboratories MEA-FDNY: 219-02-E Vol. VI Inc. CSFM: 7270-1703-0502 This document is not intended ISO 9001 Certification to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. 4llspecifications are subject to change without notice. For more information Learn more about Gamewell-FCI's Velociti° Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com 9020-0620 I 0 104/2018 162018 Honeywell International Inc. Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-1703:0502 Page 1 of I CATEGORY: 7270 -- HEAT DETECTOR USTEE: GAMEWELL-FC112 Clintonville Road, Northford, CT 06472 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Models ATD-L3, ATD-L3H (fixed temperature) and ATD-L3R (fixed temperature with Rate-of-Rise) electronic heat detectors. Suffix -IV for ivory color and -BL for black color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Model ATD-L3 (fixed temperature): 135°F. Model ATD-L3H (fixed temperature): 190°F. Model ATD-L3R (fixed temperature with rate of rise):135°F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Notifier base B71OLP (CSFM#7300-0028:173); System Sensor bases B501, B21OLP, B300-6, B300-6-IS (CSFM#7300-1653:0109); 13224131, B224RB (CSFM#7300-1653:0126); B200S, B200SR (CSFM#7300-1653:02 13); B2005-LF, B200SR-LF (CSFM#7300-1653:238); and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. XLF: 7270-0028:0502 02-01-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division SYSTEM SENSOR® Select Series Mounting Base Options System Sensor mounting bases and kits provide a variety of installation options for detectors in any application. i—I H ILJI 1•_))} _p Features Bases enable quick and secure detector plug-in SEMS screws provide easy wiring connection Support for 12-24 AWG provides installation flexibility Multiple base formats meet application requirements Standard white color with ivory and black options UL 268 compliant Mechanical locking feature restricts removal of attached sensor head Specialty Base Features Pre-wired mounting plate simplifies installation Application driven feature sets Sounder bases both UL 268 and UL 464 compliant Agency Listings S1GJIAUNG FM 0 USTED S911 3062622 4 & 6 bases: 7300-1653:0109 Relay & IsoIor bases: 1300-1653:0126 Sider s: 7135-1653:0213 Low-frequency baoe 7300-1653:0238 To meet local code and application requirements, System Sensor offers standard 4" and 6" bases, as well as, specialty base designs including relay, isolator, sounder and low frequency sounder options for Select Series detectors. The standard 4" and 6" bases offer a plug-in detector base intended for use in intelligent systems, with screw terminals provided for power (+ and -), and remote annunciator connections. Communication takes place over the power (+ and -) lines. The 4" base offers a compact design while the 6" base provides compatibility with a wider range of junction boxes. The Select Series specialty bases support application driven requirements. The bases employ a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface-mount boxes. The mounting plate enables pre-wiring of all connections to speed and simplify installation. Relay bases (B224RB-WH/B224RB-lV) provide one form C contact relay for control of auxiliary functions, such as door closure and elevator recall. The relay can operate in two different modes (short and long delay). The activation time for the short delay is 60 ms to 100 ms, while the activation time for the long delay is 6 sec to 10 sec. A shunt with pin headers, located on the base PC board, is used to set the delay timing. Isolator bases (B224B1-WH/B224B1-IV) allow the Signaling Line Circuit (SLC) loop to operate under fault conditions created from a short circuit preventing an entire communication loop from being disabled. The base isolates the section of the loop containing the short circuit from the remainder of the circuit and automatically restores when the fault is corrected. The Select Series sounder and low frequency sounder bases are designed for new and existing dwelling unit applications. They offer maximum flexibility in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. The tConsult your fire alarm control panel manufacturer for compatibility with the addressable model of the sounder base. SPDS90I-00 • 04/04/2018 • Page 1 Select Series low frequency sounder bases are designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent. Studies show that a lower frequency, centered around 520 Hz, is the most ideal to wake sleeping occupants, even those with mild to severe hearing loss. The B200SR sounder and LF sounder bases (B200SR-WHIB200SR-IV/B200SR-LF-WH/ B200SR-LF-IV) are fully compatible with existing B501 BH-Series sounder base installations. The device enables users to select one of two 8501 -supported tones (ANSI Temporal 3 or Continuous) through a jumper. The B200S sounder and LF sounder bases (B200S-WH/B200S-IV/B200S-LF-WH/ B200S-LF-IV) adopt the same address as the detector, but use a unique device type on the loop. The Fire Alarm Control Panel (FACP) can use that address to command an individual sounder - or a group of sounders - to activate. The command set from the FACP can be tailored to multiple event-driven tone outputs allowing selection of volume (75 or 85 dBA), tone (ANSI Temporal 3, ANSI Temporal 4 or March Time) and group. In addition, some FACPs will enable custom tone patterns. The 8200S series sounder bases recognize the System Sensor synchronization protocol. This enables it to be used as a component of the general evacuation signal - along with other System Sensor AV appliances - when connected to a power supply or FACP output capable of generating the System Sensor synchronization pulses. Specifications - Select Series Bases Diameter B501-WHITE, B501-IV, B501-BL: 4.0'(10.2 cm) B200S-WH, B200S-IV, B200S-LF-WH, B200S-LF-IV, B200SR-WH, B200SR-IV, B200SR-LF-WH, B200SR-LF4V: 6.85" (17.4 cm) B300-6, B300-6-IV. 6.1"(155 mm) B224B1-WH, B224B1-IV, B224RB-WH, B224RB-IV: 6.85" (17.4 cm) Base Height B501-WHITE, B501-IV, B501-BL: 0.74" (18.8 mm) (without sensor) B200S-WH, B200S-IV, B200S-LF-WH, B200S-LF-IV, B200SR-WH, B200SR-IV, B200SR-LF-WH, B200SR-LF-IV: 1.6-(4.1 cm) 8300-6, B300-6-IV: 0.76"(19 mm) B224B1-WH, B224B1-IV, B224RB-WH, B224RB-IV: 1.61" (4.1 cm) Weight: B501-WHITE 0.32 lb (145 gm) B200S-WH, B200S-IV, B200SR-WH, B200SR-IV: 0.50 lb (227 gm) B2005-LF-WH, B200S-LF-IV, B200SR-LF-WH, B200SR-LF-IV: Weight: 0.6 lb (272 gm). B300-6, B300-6-IV: 0.32 lb (145 gm) B224RB-WH, B224RB-IV, B224B1-WH, B224B1-IV 0.50 lb (227 gm) Wire Gauge B501-WHITE, B501-IV, B501-BL, B224B1-WH, B224B1-IV, B224RB-WH, B224RB-IV, B300-6, B300-6-IV: 18 AWG (0.823 mm2) to 12 AWG (3.31 mm2) B200S-WH, B200S-IV, B200S-LF-WH, B200S-LF-IV, B200SR-WH, B200SR-IV, B200SR-LF-WH, B200SR-LF-IV: 14 AWG to 12 AWG Temperature Range Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at systemsensor.com Humidity Range 10% to 93% RH non-condensing Operating Voltage 15 to 32 VDC Operating Voltage 15 to 32 VDC Standby Current 150 pA Standby Current 170 pA max. Set Time Position 1, Short Delay: 60 to 100 ms Position 2, Long Delay: 6 to 10 sec Electrical Specifications: Reset Time 20 ms max. Operating Voltage 15 to 32 VDC Standby Current 170 pA max. Operating Voltage 15 to 32 VDC Standby Current 450 pA max. Isolation Current 15 mA max Relay 2 coil latching relay Characteristics 1 Form C contact UL/ULC Rating: CURRENT RATING MAXIMUM VOLTAGE LOAD DESCRIPTION APPLICATION 2A 25 VAC PF = 0.35 Non-coded 3A 30 VDC Resistive Non-coded 2A 30 VDC Resistive Coded 0.46 A 30 VDC (L/R = 20m5) Non-coded 0.7 A 70.7 VAC PF = 0.35 Non-coded 0.9 A 125 VDC Resistive Non-coded 0.5 A 125 VAC PF = 0.75 Non-coded 0.3 A 125 VAC PF = 0.35 Non-coded SPDS901-00 • 04104/2018 • Page 2 External Supply Electrical Ratings External Supply Electrical Ratings External Supply 16 to 33 VDC (VFWR) External Supply 16 to 33 VDC (VFWR) Voltage Voltage Standby Current: 500 pA maximum Standby Current: 550 pA maximum VDC Alarm Current: 35 mA maximum (at high volume setting); Alarm Current, High-volume setting 15 mA maximum (at low volume setting) SLC Electrical Ratings SLC Operating 15 to 32 VDC Voltage: SLC Standby 300 i.JA maximum Current: Sound Output High Volume: Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone) Low Volume: Greater than 75 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone) 70 mA maximum @33.0 VDC 90 mA maximum @ 24.0 VDC 140 mA maximum @16.0 VDC Alarm Current, Low-volume setting 15 mA maximum @33.0 VDC 20 mA maximum @ 24.0 VDC 25 mA maximum @ 16.0 VDC SLC Electrical Ratings SLC Operating 15 to 32 VDC Voltage: SLC Standby 300 pA maximum (base only, refer to Current: applicable sensor specification) Sound Output High Volume: Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone) Low Volume: Greater than 75 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone) External Supply Electrical Ratings External Supply 16 to 33 VDC (VFWR) Voltage Standby Current: 500 pA maximum Alarm Current: 35 mA maximum SLC Electrical Ratings SLC Operating 15 to 32 VDC Voltage: SLC Standby 300 pA maximum Current: Sound Output Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone) External Supply Electrical Ratings External Supply 16 to 33 VDC (VFWR) Voltage Standby Current: 1 mA maximum VDC Alarm Current 65 mA maximum @ 33.0 VDC 90 mA maximum @ 24.0 VDC 125 mA maximum 016.0 VDC SLC Electrical Ratings SLC Operating 15 to 32 VDC Voltage: SLC Standby Refer to applicable sensor specification. Current: Sound Output Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone) SPDS901.00 • 04/04/2018 • Page 3 TR300 Trim Ring Select Series Junction Box Selection Guide B501-WHITE, B501-IV, No No Yes No No Yes Yes Yes Yes No B501-BL B200S-WH, B200S-IV, B200S-LF-WH, B200S-LF-IV, B200SR-WH, B200SR-IV, Yes Yes Yes Yes Yes Yes No No No No B200SR-LF-WH, B200SR-LF-IV B300-6, B300-6-IV Yes No Yes Yes Yes Yes No No No No 8224B1-WH, B224Bl-IV Yes Yes Yes Yes Yes Yes No No No No B224RB-WH, B224RB-IV Yes Yes Yes Yes Yes Yes No No No No * with 3.0" mud ring Note: Box depth contingent on base and wire size. Refer to National. Electric Code or applicable local codes for appropriate recommendations. Ordering Information Model Description White Ivory Black B501-WHITE B501-IV B501-BL 4" Flangeless mounting base Accessories 13501-WHITE-BP - - 4" Flangeless mounting base bulk pack, white B300-6 B300-6-IV - 6" Flanged mounting base RA100Z 8300-6-BP - - 6" Flanged mounting base bulk pack, Remote LED white Annunciator B200S-WH B200S-IV - Intelligent addressable sounder base B200S-LF-WH B200S-LF-IV - Intelligent addressable sounder base, low-frequency B200SR-WH B200SR-IV - Standard sounder base (compatible with B501 BH series) B200SR-LF-WH B200SR-LF-IV - Low-frequency sounder base (compatible with B501 BH series) CK300-BL B224B1-WH B224B1-IV - Isolator base - Color Kit B224RB-WH B224RB-IV - Relay base Related Accessories White Ivory Black CK300 CK300-IV CK300-BL Color kit (includes cover and trim ring) CK300-IR CK300-IR-IV CK300-IR-BL PTIR Color kit (includes cover and trim ring) TR300 TR300-IV - Trim ring - SMB600 Surface mounting kit (flanged), ivory RA100Z - - Remote LED annunciator M02-04-00 Detector test magnet M02-09-00 Test magnet with telescoping handle "STEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2O18 System Sr. Phone: 800-SENSOR2 • Fax: 630-377-6495 for ~srd pmduct Mrmatm, kduding the latest version of #ft data sheet. SENSOR www.systemsensor.com SPOS901.00 • 04/04/2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com,,' DESIGN: Models B401, B401B, B401 40113R, B401BR-750, B401R-750, B402B, B404B, B404BT, B406B, B501, B501B, 156587-002, B501BH, B501BHT, 13401131-1, B110LP, B110RLP, B1I0RLP750, B112jB114LP, B114LPBT, B116LP, B21OLP, B501-BL, B501-IV, *B501..wLdlTE B300-6, B300-6-IV, B300-6-IS detector bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, *model number, *electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. *Refer to Manufacturers Installation Instruction Manual for details. NOTE: Formerly 7300-1209:128 *Rev 04-03-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division df-50673:Rev • F-850 302 Series Rate-Anticipation Heat Detectors General The Thermotech 302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 135°F (57.2°C) or 194°F (90°C) ratings. The 302 Series are normally-open devices designed espe- cially for fire detection and alarm systems. Features Immediate response. The 302 Series activate whenever ambient air temperature reaches a detector's setting, elimi- nating the thermal time lag inherent in conventional heat detectors. Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Universal application. The 302 Series can be used in all areas for any type of occupancy. Self-restoring. Hermetically sealed. Shock resistant, corrosion resistant, and tamper-proof. Principles Of Operation The 302 Series rate-anticipation heat detectors respond and activate the fire alarm immediately whenever the ambient tem- perature reaches the preset temperature setting. Under rapid heat rise conditions, the rate-anticipation feature enables the detector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature fluctuations below the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automatically resets itself. Dimensions (Model 302) Total overall length: 4-1/8" (10.48 cm). Base diameter: 2" (5.08 cm). Electrical Ratings Voltage Current 6-125VDC 5amps 6-25VDC lamp 125 VDC 0.5 amp Application Information 302 Series detector have a smooth ceiling UL rating of 50 x 50'(15.24 x 15.24 meters) and are the only type of heat detec- tors having such a rating on both fixed temperature and rate anticipation. ORM-LITerALWMS by Honeywell 1271phol.jpg Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S539 (302-AW-1 35/-194; 302-ET-135/-194; 302-135-194) FM Approved: (302-AW-135/-1 94; 302-ET-135/-194; 302-135/-194) CSFM: 7270-0021:001 1271 diI.l,I FINE SILVER CONTACT POINTS EXPANSION STRUTS H0311 EXPANSION SENSING SHELL 0.040 ANODIZED ALUMINUM HEAT ANTICIPATION CONTROL SLEEVE SETTING SCREW DEVCON HERMETIC SEAL Cut-Away View df-50673: Rev • 02/03/09 - Page 1 of 2 Thermotech Model 302 Series Rate-Anticipation Heat Detectors Model Number Description Refer To 302-135 135°F Interior Vertical Mounting Note 1 below 302-194 194°F Interior Vertical Mounting 302-AW-1 35 135°F All-Weather Vertical Mounting Note 2 below 302-AW-1 94 194°F All-Weather Vertical Mounting 302-ET-135 135°F All-Weather Vertical Mounting Note 3 below 302-ET-194 194°F All-Weather Vertical Mounting 302-EPM-135 135°F Explosion Proof Mounting Note 4 below 302-EPM-194 194°F Explosion Proof Mounting AP-P Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4" outlet box. NOTE 1: For interior mounting in any atmosphere that is compatible with terminal-screw-type connections. UL rating 50'x50'(15.24 x 15.24 meters). NOTE 2: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox when the all-weather leads are properly spliced to 'THW" or equivalent type wire. NOTE 3: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover, or any outlet box. NOTE 4: Explosion-proof for installation in hazardous locations. Has hexagonal wrench-grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co., or equal. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 1311111191111111 & MMIM1URINJ All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— df-50673:Rev • 02/03/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 9 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0021:0001 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: , UT 84414 Thermotech Inc.,2900 North 100 /F(801) Contact: Lee Barker (801) 782-2 782-1746 Email: thermotechinc@hotmail.c DESIGN: Models 302, 302H, 302AW, 302ET and 302EPM heat detectors. Units are open circuit, 1350 F, 1940 F fixed temperature and rate-of-rise type heat detectors. Models 302 and 302-H are for indoor use. Models 302-ET or 302-AW are for all weather use. Model 302-EPM is suitable for use in Class I, Groups C and D and Class II, Groups E, F and G hazardous locations. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 6-125 VAC orVDC, 125 VDC 1350 F, 1940 F fixed temperature and rate-of-rise INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models 302, 302-ET and 302-AW are for intended for vertical mount and Models 302-H is intended for horizontal m'ount only. MARKING: Listee's name, model number, electrical and temperature rating and UL label. APPROVAL: Listed as fixed temperature and rate of rise type heat detectors for use with separately listed compatible fire alarm control units. *Rev. 05-01-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Honeywell MS-7 Series Addressable Devices Manual Fire Alarm Pull Stations GeneraL The Gamewell-FCI, MS-7 Series manuaIf ire alarm pull stations are available in a wide variety of configurations. The pull stations comply with the Americans with Disabilities Act (ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All putt stations include a key lock/resetwhich is keyed alike with the Gamewell-FCI fire alarm control panels and other manual fire alarm pull stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti Series addressable station is a double action pull station designed for installation in the signaling line circuit of Gamewell-FCl analog addressable control panels. Activation of the pull station causes its assigned address to register at the fire alarm control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The station features screw terminals. MS-7 Series MS-7ASF Velociti Addressable Station The MS-7ASF Velociti Series addressable pull station is a single action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the pull station is activated.* The station features screw terminals. The Velociti Series pull stations use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and focuses on the single device. The net effect offers a response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action pull station is used with conventional fire alarm control panels. It features a set ofsingle pole contacts and screw terminals for connection to an initiating circuit. FEATURES & BENEFITS Addressable stations The pull stations (MS- Offers surface or semi- Includes a tumbler lock *Only the red LED is compatible with all 7LOB) are Listed for flush mounting fortest and reset keyed operative in panels that Gamewel(-FCl analog outdoor applications alike with analog do not operate in Velociti addressable fire alarm Shock and vibration addressable fire alarm mode controls Complies with ADA pull resistant controls force requirements Conventional stations Both single and double suitable for use with action pull stations any UL Listed control available panel MS-7S Single Action Station The MS-7S single action pull station is used with conventional fire alarm control panels. It features a set of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action pull station similar to the MS-7 station, with the additional feature of including both English and Spanish instructions molded into the unit. MS-7LR Dual-action Agent Release Station The MS-7LR is designed for usewith the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems. It features a set of single pole contacts and screw terminals used to connect to an initiating circuit. MS-7LRA Agent Release Station with Abort The MS-7LRA is designed for use with the Gamewell- FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabilities are required. It consists of the following: An MS-7LR mounted on a plate with an abort switch LED indicators that signal system normal and system activated status MS-71_013 Double Action Station (Listed for Outdoor Applications) The MS-71_013 station must be mounted on a Model SB-I/O backbox. In retrofit applications, the pull station is UL Listed for use with the WP-10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior pull stations may be surface mounted or semi-flush mounted on a standard double-gang, or4-inch (10.2 cm) square electrical box. An optional trim ring (BG12TR) may also be used for semi-flush mounting. NYC-Plate The NYC-Plate provides the backplate for the manual pull station. (See Figure 1). Figure 1 NYC-Plate Ordering Informjpr(' MS-7: Doubçstation MS-7APelociti addressable double action station MS_TASF**: Velociti addressable single action station MS-7S: Single action station, wire leads MS-7SP: Double action station, English and Spanish instructions MS-7LR: Agent release station, dual-action MS-7LRA: Agent release station with abort switch, LED indicators, dual- action MS-7LOB: Double action station, outdoor use (Includes SB-I/O - Indoor/outdoor use backbox) SB-I/O: Indoor/outdoor use backbackbox SB-10: Surface backbox BG12TR: Trim ring for semi-flush mount, plastic NY-PLATE: NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. MS-7 Series Technical. Specifications SYSTEMS Material: Lexan Contact Ratings: 0.25 amps. @ 30 VAC/VOC (resistive) Dimensions: 55/8" H x 41/4"W x 1/4"D (14 x 10.1 x 3.2 cm) Operating Temperature: (MS-7AF, MS-7ASF): 32° to 120° F (00 to 49° C) (MS-7 LOB): -301 to 150° F (-350 to 66° C) Relative Humidity: (MS-7AF, MS-7ASF): 10 to 93°/c (non-condensing) (MS-7 LOB): 85°/c ± 5°/c @ 861± 3.60 (301± 2° C) Alarm Current: .0030 amp. 0.007 for LED Supervisory Current: (MS-7AF, MS-7ASF): .00030 amps. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 491C/32 - 120°F and at a relative humidity 93°/c ± 2°/c RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 271C/60 - 80°F STANDARDS The MS-7 Series is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2465 FM: 3023594 MEA FDNY: 67-02-E Vol. VII CS FM: 7160-1703:0119 7160-1703:0170 7160-1703:0109 ISO 9001 Certification For a complete listing of all compliance approvals and certifications, please visit: http:!/www.gamewell- fci.com!en-US/ documentation/Pages! Listings.aspx LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. Velocitie and Gamewell-FCI are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. For more information Learn more aboutGamewell-FCI's MS-7 Series and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com 9020-0616 I F I 11/17 @2017 Honeywell International Inc. Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1703:0119 Page 1 of 1 CATEGORY: 7150 - FIRE ALARM PULL BOXES LISTEE: GAMEWE/ Bnt intonville Road, Northford, CT 06472 Contact: L 03) 484-6105 Fax (203) 484-7309 Email: lisa eywell.com DESIGN: Model MS-7AF dual action fire alarm pull box. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. NOTE: Formerly: 7150-0694:261 XLF: 7150-0028:0199 *Updated 09-08-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Honeywell I Addressable Devices AMM-2F Addressable Monitor Module General The Gamewell-FCI Velociti® Series, addressable monitor module AM M-2F is a single Style B, Class B initiating device circuit (IOC) with a 47KW end-of-line resistor. This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell-FCI addressable series fire alarm control panel. Any initiating device with normally open (NO.) dry contacts may be made addressable when connected to the AMM-2F module. The Velociti®Seriems use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. _•)• AMM-2F The AMM-2F module can be programmed to provide a wide variety of input functions to the Gamewetl-FCI addressable series fire alarm control panels. It can be identified as a manual station, heat detector, plenum detector, waterflow switch, tamper switch, N.C. contact, smoke detector, projected beam smoke detector, sub loop, remote zone, etc. It can also serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possible to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-2F can support a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. The compact size facilitates the installation of the module inside manual stations, or mounting boxes of various types of alarm initiating devices. Ordering Information AMM-2F: Addressable monitor module, single circuit, Style B, Class B FEATURES & BENEFITS Compact size allows • Class B, Style B, • 40 Ohm line resistance • Connects to any easy installation initiating circuit for each initiating normally open dry device circuit contact device AMM-2F Technical. Specifications System STANDARDS For a complete listing of all compliance approvals and Supervisory Current: .000375 amps The E3 Series Control Panel is designed to comply with certifications, please visit Alarm Current: .00060 amps the following standard: http://www.gamewell- Operating Temperature: 320 to 120° F (00 to 49° C) UL Standard: UL 864 9th Edition fci.com/en-US/ documentation/Pages! Relative Humidity: 10 to 93°/c (non-condensing) AGENCY LISTINGS AND APPROVALS Listings.aspx End-of-Line Resistance: 47K ohms These listings and approvals apply to the modules Velociti and Gamewell-FCI® Dimensions: 1.3" Lx 2.5"W x 0.5" D specified in this document. In some cases, certain are registered trademarks of (3.3 x 6.4 x 1.3 cm) modules or applications may not be listed by certain Honeywell International Inc TEMPERATURE AND HUMIDITY RANGES approval agencies, or listing may be in process. UL is a registered trademark This system meets NFPA requirements for operation at 0 Consult factory for latest listing status. of Underwriters Laboratories - 491C/32 - 120°F and at a relative humidity 93% ± 2°/c UL: S1949 Inc. RH (noncondensing) at 32°C ± 2°C (90°F ± 319. FM: 3023594 This document is not intended However, the useful life of the system's standby batteries MEA FDNY: 227-03-E VOL. IV to be used for installation purposes. and the electronic components may be adversely affected CSFM: 7300-1703:0102 We try to keep our by extreme temperature ranges and humidity. Therefore, ISO 9001 Certification product information up-to- date and accurate We cannot it is recommended that this system and its peripherals be cover all specific applications installed in an environment with a normal room or anticipate all requirements. temperature of 15— 27°C/60 - 80°F. All specifications are subject to change without notice. For more information Learn more about Gamewell-FCI's AMM-2F and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 9020-0626 1 F 1 11/17 Honeywell ©2017 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1703:0102 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: GAMEWELL-FC112 Clintonville Road, Northford, CT 0 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7)9 Email: Iisa.brant@honeywell.com DESIGN: Models AMM4, *AMM4F AMM-2 and *AMM2F monitor modules and Models ACM, AOM-2, AOM-2R, *AOM..2RF AOM-25 and *AOM..2sF control modules. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as accessories for use with separately listed compatible control units. System Sensor Model SMB500 surface mount box (CSFM Listing No. 7300-1653:103) may be used as an enclosure for these modules NOTE: FORMERLY: 7300-0694:178 XLF: 7300-1653:0103 12-4-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Gamewefl 0j!!!::: - rr7Ini CONTROL tLJ INSTRUMENTS by Honeywell InnevairFiefm Series INIIINIW Duct Smoke Housing Description The InnovalrFlexrm Series, DNR intelligent, non-relay pho- toelectric duct smoke detector, and the DNRW watertight, non-relay photoelectric duct smoke detector feature a piv- oting housing that fits both square and rectangular foot- prints. These detectors are capable of mounting to a round or rectangular duct The DNR/DNRW detectors can be used with the E3 Series®and 7100 Series Systems. Note: The lnnovairFlex Series, DNR requires the Veloc- iti® Series, ASD-PL2FR Sensor and AOM-2RF, if relays are required for the fan control. The DNRW duct smoke detector, with its NEMA 4 rating, is Listed as a watertight enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water. These features allow operators to use the detector in the most extreme environments. The units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of -4°F to 158°F. and a humidity range of 0 to 95 percent (non-condensing). An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. A cover tam- per feature was added to indicate a trouble signal for a removed or improperly installed sensor cover. The lnnovairFlex housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of the relay module. The lnnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFiex product line is compatible with all previous Innovair models, including remote test accessories. WARNING:Duct smoke detectors have specific limitations. DUCT SMOKE DETEC1ORS ARE: NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection, and NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional duct smoke detector 2911 application information. E3 Senes®and velociti®are registered trademarks and innovarFlexTm Is trademark of Honeywell International, Inc. tiL®lS a registered trademark or Underwriters Laboratories Inc. Intelligent Non-Relay Photoelectric Duct Smoke Housing Features Photoelectric, integrated low-flow technology Air velocity rating from 100 ItImin to 4,000ft1min (0.5m/s to 20.32m/sec) Versatile mounting options: square or rectangular configuration Bread ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required New Cover tamper signal Increased wiring space with a newly added 3/4-inch conduit knockout Available space within housing to accommodate the mounting of the relay module Easily accessible code wheels on sensor head (sold separately) Clear cover for convenient visual inspection tJL® 268A Listed Remote testing capability Requires SLC line power only NEMA Type 4 UL Listed for non-hazardous indoor and outdoor applications (DNRW only) UV Resistant, UL® Listed housing and cover material (DNRW only) An ISO 9001-2000 Company 9 FM LUTE APFFvvm 2202 A 0 5911 3029700 2207 7272-1703:0121 5911 11 GAMEWELL-FCI 12 Clintonville Road, Northtord CT 06472-1610 USA 'Tel: (203)484-7161 ° Fax: (203) 484-7118 Sa1Oaeb-irtaTmtedOrly aenl i1asI for irIaai p xs .anI aes4ectiethargewtflaJtrTe No.eW3 biltyisa3ainEdbyGmBNetfUtbrftruse MbyH0n*%'dllMxnabord Inc. Jrttsr. www.gamewell-fci.com 9021-60475 Rev 0 page 1 of 4 Architectural/Engineering Specifications The air duct smoke detector shall be a System Sensor lnnovairFlex DNR Intelligent Non-Relay Photoelectric Duct Smoke Detector and DNRW Watertight NEMA4 Duct Smoke Detector. The detector housing shall be UL Listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 ft/min to 4,000 ft/mm (0.5 m/sec to 20.32 m/ sec). The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS151 KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Physical Specifications Size: Rectangular Dimensions: 14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.6 cm) Depth Square Dimensions: 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight 1.6 lb (0.73 kg) Environmental Rating: NEMA4 (DNRW only) Operating Temperature Range: 4° to 158°F (-20° to 70°C) Storage Temperature Range: —22° to 158°F (-30° to 70°C) Operating Humidity Range: 0% to 95% relative humidity non-condensing Air Duct Velocity: 100 to 4000 ft/mm (0.5 to 20.32 m/sec) DCOIL - (if included) 17.5- 26.4 VDC .95mA max. Electrical Ratings For information on the electrical specifications, refer to the lnnovairFlex DNR Duct Smoke Detector Installation Instructions, PIN 156-3051-001R. Accessory Current Loads at 24 VOC Device Standby Trouble RAIOOZ 0 mA 12 mA Max. RTSI5I!RTSI5I KEY 0 mA 12 mA Max. Installing the InnovairFIex Sampling Tube The InnovairFIex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab. (Figure 3 illustrates the front locking tab). Rg.rel Rre2 Rne3 OAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60475 Rev. D page 2 of 4 www.gameweIl4cl.com Wiring for Intelligent Non-Relay Duct Smoke Detector I----, I- comm. LINE COMM. LINE I I COMM. LINE ULIFM LISTED I 1ST 2ND CONTROL DETECTOR DETECTOR PANEL IN LOOP IN LOOP Figure 4 System Wiring Diagram for DNR RAIO& REMOTE ALARM LED OPTION 1 PER UNIT Figure 5 DNR to RAIOOZ DNR 10 RTS4SI!RTS45IKEYIRTSI5II RTSI5IIEY WIH 'R" REMOTE TEST CAPABLE DETECTOR HEAD OPTION: 1ESTc0IL+ 451/451KEY 1TQ1L+ 1ESTCOIL _ R1151/R75151 KEY 1FQiL- OMM+ OUT(CONV ONLY) + Wr(OCWCPI.Y) + e R51151 KEY RRIS- J RE MOIE TEST STATION cOMM. ' - RNRTS LEO OPTION I PER LIET I RIS+ RA+@ - RTS + 1ESTCOILOPTION I PER (Nif - 5 95nACUREENTDRAW Figure 6 DNR to RTSI5IIRTSI5I Key Important Notes: The use of either RTS 151 or RTS1 51 KEY requires the installation of an accessory coil, DCOIL, sold separately. For additional information, refer to the DNR or DNRW Duct Smoke Detector Installation Instructions, PIN 156-3051-001 R and the Duct Application Smoke Detectors Application Guide. The RTS1S1/RTS151KEY test coil circuit requires an external 24 VDC power supply which must be UL Listed. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA• Tel: (203) 484-7161 Fax: (203) 484-7118 www.gamewell.fci.com 9021-60475 R. 0 page 3 of 4 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accesso- ries are UL Listed. - -. ini. IN __ r. Ordering Information Part ber Description DNR Intelligent non-relay photoelectric low-flow duct smoke detector DNRW Watertight intelligent non-relay photoelectric low-flow duct smoke detector ASD-PL2FR Intelligent photoelectric smoke sensor with remote test capability in duct applications Accessories Part Number Description DCOIL Remove test coil required with RTS151/RT5151151KEY DSTI Metal sampling tube duct width up to 1 ft (0.3m) DSTI .5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DSTI .5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) DS75 Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m) DSTIO Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) DH4000E-1 Weatherproof enclosure ETX Metal exhaust tube duct width 1 ft (0.3m) M02.04.00 Test magnet P48-21-00 End cap for metal sampling tubes RAIOOZIRAIOOZA Remote annunciator alarm LED RTSI5I Remote test station RTSI5I KEY Remote test station with key lock GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60475 Rev. 0 page 4 of 4 www.gamewelI.fci.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-1653:0209 Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Br (203) 484-6105 Fax (203) 484-7309 Email: lisa.6thoneywell.com DESIGN: Models DNR, DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. 01-02-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WaNG, Program Coordinator Fire Engineering Division Honeywell Addressable Devices *Ga II Velociti® Series 3 Detectors Photoelectric Detectors Description The Gamewell-FCI, Velociti® Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern bright white color, the Velociti Series 3 is aesthetically pleasing for today's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations. The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCl, ASD-PL3 photoelectric detector's re-designed optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment. The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR (DNRW) duct smoke detector housing. The ASD-PTL3 multi- sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 135°F fixed temperature thermal sensing. For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number after the detector model. Note: Although the E3 Series® and S3 Series panels support both the Velociti® and CLIP protocols, the GWF-7075 panel does not support the CLIP protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. Photoelectric Detector FEATURES & BENEFITS Complies with UL® Standard 268 7th Edition Designed with anew profile to offer modern and improved aesthetics Contains a built-in functional test switch activated by external magnet Supports low standby current Supplies optional relay, isolator, or sounder bases (standard or low frequency) Provides rotary address • Includes dual LEDs for • Offers expanded color switches (01-159) 3601 visibility options Ordering Information NOTE: -IV suffix indicates Ivory color model. NOTE-"-BL's !idcates Black color model. NOTE: "WH" fiJes Bright White color model. ASD-PL3:*foelectric smoke detector, bright white, Velociti ASD-PL3R: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, bright white, Velociti ASD-PTL3: Photoelectric smoke detector with thermal sensing, bright white, Velociti ASD-PL3-IV: Photoelectric smoke detector, ivory, Velociti/ CLIP ASD-PL3R-IV: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, ivory, Velociti/CLIP ASD-PTL3-IV: Photoelectric smoke detector with thermal sensing, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540. Note: "IV" suffix indicates Flashscan and CLIP devices. "WH" suffix indicates bright white• B501-WHITE: 4" Flangeless mounting base, bright white B501-WHITE-BP: 4" Flangeless mounting base bulk pack, bright white B501-IV: 4" Flangeless mounting base, ivory B300-6: 6" Flanged mounting base, bright white B300-6-IV: 6" Flanged mounting base, ivory B300-6-BP: 6" Flanged mounting base bulk (Pack of 10) B200SR-WH: Standard sounder base, bright white B200SR-IV: Standard sounder base, ivory B200S-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B200S-LF-WH: Intelligent addressable low frequency sounder base, bright white B200S-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB_IV: Relay base, ivory B224B1-WH: Isolator base, bright white B224B1-IV: Isolator base, ivory DNR: Intelligent duct detector housing, non-relay DNRW: Intelligent duct detector housing, non-relay, watertight FA Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6" Base, bright white TR300-IV: Accessory Flange Ring for B300 6" Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single-gang electrical box. For use with B501 and 8300-6. CK300: Bright White detector kit (Pack of 10) CK300-IR: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCSCOF Series detectors. (Pack of 10) CK300-BL: Black detector kit. (Pack of 10) CK300-IR-Bl: Black, detector color kit for use with MCSCOF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR213: Detector removal tool. Allows the installation and/ or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole for XR2B. Shipped with three, 5-foot (1.524,m) sections. Velociti® Series 3 Detectors Technical. Specifications SYSTEMS Photoelectric Intelligent Detector: Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.49 cm) installed in 8300-6 base 4 inches (10.16 cm) installed in B501 base Shipping Weight: 3.4 oz (96.4 g) Operating Temperature Range: Photo: 32° F to 122° F (0° C to 50° C) Photo in Duct Applications: -4° F to 158° F (-20° C to 70° C) Photo with Thermat 32° F to 100° F (0° C to 38° C) Operating Humidity Range: 10% to 93% non-condensing Rate-of-Rise Detection: Responds to greater than 151F/minute or 135°F (8.3° C/minute or 57°C Air Velocity Range: 0 to 4,000 ft/mm (0 to 1219.2 m/min) Electrical Specifications Voltage Range: 15 to 32 VDC Standby Current (@24 VDC): 200 UA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.): 2 mA @ 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.): 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 STANDARDS The Velociti® Series 3 Photoelectric Detectors are designed to comply with the following standard: UL Standard: UL 268 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2332 FM: 3023594 MEA FDNY: COA-219-02-E Vol. VI CSFM: 7272-1703:0501 ISO 9001 Certification For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages! Listings.aspx E3 Series®, Velociti® and Gamewe[l-FCI® are registered trademarks of Honeywell International Inc. UL® i a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We Cannot Cover all specific applications or anticipate all requirements. All specifications are subject to Change without notice. For more information Learn more about Gamewell-FCI's Velociti® Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com 9020-0617 I K 104/2018 @2018 Honeywell International Inc. Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1703:0501 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: GAMEWELL-FC112 Clintonville Rp Northford, CT 06472 Contact:L'isa Brant (203) 484-(05 Fax (203) 484-7309 Email: lisa.brant@honeYwejbm DESIGN: Models ASD-PL3, ASD-PL3R, and ASD-PTL3 analog addressable, photoelectric smoke detectors for open area and duct installations. Model ASD-PTL3 has a complementary heat detector. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed System Sensor base Models *13501 *B21OLP (CSFM Listing 7300-1653:0109), B200S and B200SR (CSFM Listing 7300-1653:0213), B200S-LF and B200SR-LF (CSFM Listing 7300-1653:0238), B300-6 and B300-6-IS bases (CSFM Listing 7300-1653:0109), *B224B1 and *B224RB (CSFM Listing 7300-1653:0126), System Sensor duct detector housings Models DNR and DNRW (CSFM listing 3240-1653:0209) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. *All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition, January 11, 2016. XLF: 7272-0028:0503 *Revision 12/17/19 DCC This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division SYSTEM SENSOR Duct Smoke Detector Accessories Expand the versatility of the /nnovairFlex" line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories APA151 Piezo Annunciator MHR Mini-Horn, Red MHW Mini-Horn,White RA 100Z/RA 100ZA Remote Annunciator RTS1 51 ote Test Station _._-1n RTS151KEY Remote Test Station with Key P152 Multi-Signaling Accessory AOS Add-On Strobe Duct smoke detector accessories add functionality to the duct smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All System Sensor duct smoke detectors and accessories are UL listed. The APAIS1 piezo annunciator, which replaces the APA45 1 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply with NFPA 90A. The MHR and MHW SpectrAlert Advance mini-horns feature RTS2-AOS Multi-Signaling Accessory temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. The RA1 OOZ and RA1 OOZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. The RTS1S1 and RTS151KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the P15151 KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. Agency Listings @ <~> 0 USTED The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFIex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately).The AOS (Add-On Strobe) is an optional accessory included with the RTS2-AOS model. Specifications, Duct Smoke Detector Accessories Voltage Regulated 24 VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 0°C to 49CC (32°F to 1201) Relative Humidity 10 to 93% non-condensing Wire Gauge 12 to 18AWG Dimensions 4.6 H x 29W x .45 D Voltage Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 VDC or FWR Opera ting Voltage 8 to 33VDC (9 to 33VDC with Sync-Circuit- Module) Sounder Current Draw 22 mA RMS max at 8 to 17.5 Volts DC 17 mA RMS max. at 8 to 17.5 Volts FWR 29 mA RMS max at 16 to 33 Volts DC 25 mA RMS max at 16 to 33 Volts FWR Temperature Range 0°Cto49°C (32°F to 120°F) Humidity Range 10 to 93% non-condensing Nominal Sounder Frequency 3kHz Wire Gauge 12t0 18AWG Dimensions 4.6 H x 2.9-W x 045D Voltage Range Conventional System: 3.1 to32VDC Intelligent System: 18 to 32VDC Maximum Alarm Current 12 mA Dimensions 4.6 H x 2.8'W x13"D Power Requirements Alarm LED: 2.8 to 32 VDC 12 mA max Total Current: 105 mA max Test Switch 10VA@32VDC Reset Switch 10 VA @ 32 VDC Alarm Response Time 40 seconds max. Temperature Range -1 09C to 60°C (14°F to 140°F) Relative Humidity . 95% non-condensing Wire Gauge 14 to 18AWG Dimensions 4.8'Hx2.90Wx 1.4D Power Requirements Power LED (Green): 14 to 35VDC. 12 mA max. Alarm LED (Re: 2.8 to 32VDC, 12 mA max. Total Current: 105 mA max Alarm Response Time 40 seconds max. Temperature Range -10CC to 60CC (14°f to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 18AWG Dimensions Voltage Muld-signaling 4.6Hx275'Wx 1.8D Accessory 20 to 29 VDC Power Requirements Standby: 3.0 mA max Trouble: 16.0 mA max. Alarm without strobe: 30 mA max Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range -10CC to 60-C (14-F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22AWG Dimensions 4.8Wx 5.3Hx 1.6'D For the very latest product specifications and listing information, please visit the System Sensor Web site at wwwsystemsensor.com. All RTS151 UL S4011 R15151 KEY ULS2522 APA151 ULS4011 RT52-AOSULS2522 I RA100ZULS2522 MHWULS4O11 MHRULS4O11 AOS "57EM 3825 Ohio Avenue. St. Charles, IL 60174 Z-4 SENSOR' Phone: 800-SENSOR2 'Fax: 630-377-6495 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0212 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6)5 Fax (203) 484-7309 Email: lisa.branthoney%Jim DESIGN: Models RTS151, RTS151 KEY and RA100Z Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division AOM-2RF Honeywell I Addressable Devices Velociti Series® AOM-2RF Addressable Output Relay Control Module General The Gamewell-FCI Velociti Series, addressable output relay control module (AOM- 2RF) allows a Gamewell-FCI analog addressable fire alarm control panel to switch discrete relay contacts by code command. The relay provides two isolated sets of Form-C contacts which transfer simultaneously. Circuit connections to the relay contacts are not supervised by the module. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the SLC devices and certain Gamewell-FCI analog addressable fire alarm control panels. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net result produces a superior response speed up to five times greater than earlier designs. The AOM-2RF Module is designed for installation in the signaling line circuit of any Gamewell-FCI analog addressable fire alarm control panel. The module contains a panel controlled LED. The AOM-2RF is designed to mount in a 4(10.16cm) square junction box 2 1/8' (5.53 cm) deep. Ordering Information AOM-2RF: Addressable output relay control module Table 1 lists the relay contact ratings. CURRENT RATING MAXIMUM VOLTAGE LOAD DESCRIPTION APPLICATION 34 30 VDC Resistive Non-Coded 24 30 VDC Resistive Coded 0.94 110 VDC Resistive Non-Coded 0.54 125 VAC Resistive Non-Coded 0.5A 30 VDC Inductive (L/R=5ms) Coded 14 30 VDC Inductive (L/R=2ms) Coded 0.54 125 VAC Inductive (PF=.35) Non-Coded 0.74 75 VAC Inductive Non-Coded Table 1: Relay Contact Ratings FEATURES & BENEFITS Listed under UL" Standard 864 Offers two sets of Form "C" contacts Provides visual rotary, decimal switch addressing (01-159) Includes a bi-cotor LED that flashes green whenever the module is addressed, and lights steady red upon activation* Designed as a compact size to allow easy installation Note 1: Only the red LED is operative in panels that do not operate in Velociti' mode *Note 2:The bi-color LED functionality is not available on the GWF-7075 panel. Velociti Series® AOM-2RF Technical Specifications SYSTEMS Supervisory Current: .000375 amps. Average Operating Current: 255 uA (Velociti Mode) 230 uA (CLIP Mode) Alarm Current: .0065 amps. Operating Temperature: 320 to 120° F (01 to 49° C) Relative Humidity: 10 to 93% relative humidity (non- condensing) Dimensions: 41/2" H x 4"W xl 1/4" (11.4 x 10.2 x 3.2 cm) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 490C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 309. However, the useful life of the systems standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 270C/60 - 80°F STANDARDS The Velociti Seriesa AOM-2RF is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S1913 FM: 3023594 FDNY: COA-219-02-E Vol. VI CSFM: 7300-1703:0102 ISO 9001 Certification For a complete listing of all compliance approvals and certifications, please visit http://www.gamewell- fci.com/en-US/ documentation/Pages! Listings.aspx Velociti® Series and Gamewell- FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. For more information Learn more about Gamewell-FCI's Velociti Series° AOM-2RF and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com 9020-0625 I I 104/19 6)2019 Honeywell International Inc. Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1703:0102 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: GAMEWELL-FC112 Clintonville Road, Northford, CT 06472 Contact: Lisa Brant (203) 484-6)d5 Fax (203) 484-7309 Email: lisa.brant@honeywell. DESIGN: Models AMM-4, *AMM..(AMM..2 and *AMM..2F monitor modules and Models AOM, AOM-2, AOM-2R, *AOM..2RF AOM-25 and *AOM..2SF control modules. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as accessories for use with separately listed compatible control units. System Sensor Model SMB500 surface mount box (CSFM Listing No. 7300-1653:103) may be used as an enclosure for these modules NOTE: FORMERLY: 7300-0694:178 XLF: 7300-1653:0103 12-4-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division The SSU-RIC-1 Relay, SPOT, provides 10.0 Amp resistive form C contacts. The relay coil may be energized by one of three input voltages: 24VDC, 24VAC, or 115VAC. SAE PN# SSU-RIC-1 RIC RIO-I, RIC-2 Series Relay Multi-Voltage Relay Module The RIC-1 and RIC-2 are ideal for applications where remote relays are required for control or status feedback. They are suitable for use with HVAC, temperature control, fire alarms, security, energy management and lighting control systems. The RIC-1 and RIC-2 Relay Modules are multi- voltage devices providing 10 Amp resistive dry form Coil Re C contacts. These relays may be energized by one Energized of three input voltages: 24VAC, 24VDC or 115VAC. LED i A red LED is provided which when illuminated, indicates the relay coil is energized. To mount the RIC Series module, simply push the self-clinching spud through a 1/2" (12.7mm) knockout on a junction box and connect via the 12" long "flying" leads. The SSU-RIC-2 Relay. DPDT, provides 10.0 Amp resistive form C contacts. The relay coil may be energized by one of three input voltages: 24VDC, 24VAC, or 115VAC. SAE PN# SSU-RIC-2 Specifications &A10 flLI n.S - ans r Ifl oou -nl'.- I COIL VOLTAGE: 24VAC/24VDC/115VAC 24VAC/24VDC/115VAC DC POLARIZED: NO NO ENERGIZED LED INDICATOR: YES YES COIL POWER REQUIREMENTS: @24VDC 18mA 18mA @24VAC 39mA 39mA @115VAC 26mA 26mA CONTACTCONFIGURATION: (1) SPDT Dry Form "C" (1) DPDT Dry Form "C" CONTACT RATINGS: Resistive @115VAC 10A 10A WIRELEADS: 12"/18AWG 12"/18AWG AMBIENTTEMPERATURE: -58"F to 185"F -58"F to 185"F (-50"C to 85"C) (-50"C to 85"C) MOUNTING: Place spud through a I2" I12.7mm1 knockout on a junction box. DIMENSIONS: H 2-1/2" 2-1/2" W 1-314" 1-3/4" 0 1-1/4" 1-1/4" LISTINGS AND APPROVALS: UL: File # S3403 File # S3403 Standard Features: 10 Amp resistive dry form C contacts Coil input voltages: 24VAC, 24VDC, or 115VAC Contains a red LED which illuminates when the coil is energized Wire nuts included for installation UL listed, file # S3403 12" wire leads Sturdy full plastic enclosure Installation Wiring "Shown in the non-energized condition - --- -------- 1 POLE #1 #2 Available On DHH RIC-2 Module Only ED (A (4 24VACNDC () 115VAC COIL COIL - U Underwriters Laboratories NOTICE: Please refer to Space Age disclaimer page for complete disclaimer notice. • Listed Space Age Electronics, Inc. 406 Lincoln Street Marlboro, MA 01752-2195 www.1sae.com ©Space Age Electronics, Inc. 2003 ED0400 LT10280 Rev. A Pg. 1/1 No Excuses Just Solutions! 800.486.1723,—voice 508.485.09661 508.485.4740—fax CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION O OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1004:0101 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Apollo America Inc.30 Corporate Drive, Auburn Hills, MI 48326 Contact: Dale Howells (248) 332-3900 Fax (248) 332-8807 Email: dale.howells@apollo-fire.com / / DESIGN: Models MR-101/C, *MR101Ic/R MR-101-SSE/C, *MRi 0i-SSE/C/RAR-194C, *MR104/C/R, *MR104SSE/C *MRi 04-SSEICIR, MR-201/C, MR-~1/C/, *MR..2o1SSE/C *MR.201..SSE/C/R MR-2041C, MR204/C/*R, *2o4E/c *MR204SsE/C/R PAM-1, PAM-2, PAM-3, PAM-4, PAM-SD, RIC-1, RIC-2, RIC-3, RIC-4, MRRIC301/*C, *MRRIC301 /C/R, MRRlC305*/C, * MR-RIC-305/C/R, MRRIC401*/C, *MR.RIC..401/C/R MRRlC405*/C and *MR..RIC..405/C/R relay modules. *Models MR-ITM/C and MR-ITM/C/R relay modules (with test mode). Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. NOTE: 1. Formerly Air Products and Controls, Inc. *Rev. 04-03-14 gt ,rI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Fire/Life Safety SmartWireTM UL Listed and Rated Type CMR or FPLR Multi-Conductor Non-Shielded Non-Plenum Fire Alarm CSFM# 7161-1727:0100 D162F6AWG2 Conductor Non-Shielded Non-Plenum Fire Alarm Description 116 AWG 2 Conductor Bare Copper, Non-Shielded Non- Plenum Fire Alarm, UL C(UL) Mlk or FPLR UL ffdKcIor Description 16 (Solid Bare Copper) -- [xnsulation PVC .O1O 1 TI1 Marking - - UFESAF rY OROL cABLE INIT. / IND. DEVICE / ZONEABCDEO 123456 7 89 16 AWG UL C(UL) CMR OR FPLR UL 75C ROHS MADE IN THE USA Overall Diameter 178" Nom. Eacitance :26 pF/Ft. Nom. -- emperature and Voltage to C to 75 C / 300 Volt Weight 1:29 Lbs/Mft. Agencies Approvals: NEC Article 800, 760; UL C(UL) CMR or FPLR UL, RoHS Compliant, Made in the USA C® Multiple Conductor Unshielded Rating: NEC Type FPL,PLTC cTL)us Listed Meets 300/ requirements Ibr Power-Limited as specified in the NEC Flame Rating: UL1685 P-rVHA-CFR Title X Part 7, SubpartK, Section 7.408 (EI 4 IMSHAI APPROVED jdMIL Primary Color Code: iption: 1. Black, 2. Red, Bare Copper 3. Brown, 4. Blue PVC Insulation Jacket: Black Shortoverall tiMstlengths Water Block Construction Overall Sunlight& (GATA Fvbistjre Resislantjacket *LINK I Conductor I Insulation I Jacket I I Nom. I I Type & I Nom. I Catalog No. of Type I Type & I O.D. I Capacitance No. Conductors I & Thickness Thickness I Between Nom. D.C.R Inches Conductors PVC 7 Strand lL• i:J 65 92 0 Aft 18AWG 1 7 Strand • UIII:IDli1 77 EW_ M P PP I !.AYIS M=1 435QAVft H2NO Water Resistant Cable is a Registered Trademark of American Data Link Inc. Primary Color Code: Description: 1. Black, 2. Red, Bare Copper 3. Brown, 4. Blue PVC Insulation Jacket: Black Shortoverall tMstlengths Water Block Construction A Overall Sunlight& (UATA iVbisture Resistantjacket *LIjIJK Multiple Conductor Unshielded Rating: NEC Type FPLIPLTC (ETL)us Listed Fvèels 300I requirements fbr Power-Limited as specified in the NEC Flame Rating: UL1685 P -FHA -CFR Title 3Q Part7, SubpartK, Section 7.407 (Et M HA IL1 APPROVED iTiIs Inches Inches - Inches - 14AWG PVC rvc H2+142 2 19Strand .023 .032 .310 24pfift 273 QAvit 14AWG PVC PVC H2+144 4 19 Strand .023 .032 .395 24pfift 273 QiMt 12AWG PVC ivc H2+122 2 19Strand .023 .032 .340 25pfift 1.71 QIMt H2NO Water Resistant Cable is a Registered Trademark of American Data Link Inc. Toll Free: 1-866-734-7082 * 724-503-4290 * Fax: 724-503-4382 48 www.american-datalink.com Power-Limited Multiple Conductor Unshielded Description: Rating: Bare Copper • NEC Type FLPRICIVR 75' C PVC insulation • cTL)us Listed Cabled construction • Weis 31W requirements Overall 75' C Sunlight Resistant as specified in the NEC PVC jacket • Flame Rating: UL1666 RoHS Compliant • P-TvHA-CFR Title 3CI Part7, SubpartK, Section 7.408 G. Primary Color Code: 1. Black, 2. Red, 3. Browi, 4. Blue Jacket: Red ut_SIS I!sj!I \U4TA APPROVED *LINK I Conductor I Insulation I Jacket I I Nom. I Type & I Nom. I Catalog No. of Type I Type I O.D. I Capacitance No. Cond. & Thickness I & Thickness j Between Nom. D.C.R Conductors 2 Solid ...r• em1 , AY11 Solid •• 29 pfAt .1YLI - —r*Solid 14. 31Thi àYII Solid ..ii -'32 pf/ft IIIt1PJ'ii Power-Limited Multiple Conductor Unshielded Primary Color Code: Description: Rating: Bare Copper • NEC Type FPLRCL3 75' C PVC insulation • (ETL)us Listed Cabled construction • Wets 30CY requirements Overall 75' C SunlightResislant as specified in the NEC PVC Jacket • Flame Rating: UL1666 RoHS Compliant 1. Black, 2. Red, 3. Brow, 4. Blue Jacket: Red 1JATA *LINK t'II! Inches Inches Inches 14 AWG PVC PVC 142F 2 Solid .012 .015 .195 2525 Q,Mft 14 AWG PVC PVC 144F 4 Solid .012 .015 .240 2525 Q,Mt I 12 AWG PVC PVC 122F 2 Solid .012 .015 .225 1.588 Q,Mft Toll Free: 1-866-734-7082 * 724-503-4290 * Fax: 724-503-4382 www.american-datalink.com 35 pfift 35 pfift 45 pfift 29 SmartWireTM Building Wire THHN, THWN-2, 190 Nylon, 1WN75 (cUL) Thermoplastic Insulated, Nylon Sheathed Heat, Moisture, Oil & Gasoline Resistant 600 Volt Copper Product Description: Windy City Wire Type THHN or THWN-2 conductors are primarily used in conduit as branch circuits in commercial or industrial applications, as specified by the National Electrical Code. Type THHN or THWN-2 are available as stranded in sizes 14 AWG - 10 AWG, and as solid in sizes 14— 10 AWG. The conductors are soft-annealed, stranded or solid copper and are insulated with a tough, heat and moisture resistant polyvinyl chloride (PVC), over which a nylon (polyamide) jacket is applied. Specifications: Windy City Wire Type THHN or THWN-2 meets applicable ASTM specifications, UL Standard 83, UL Standard 758, and UL Standard 1063. The conductors are Gasoline and Oil Resistant II, and have a voltage rating to 600 volts. All THHN is UL and cUL Listed. CSFM# 7161-1727:0100 r Conductor AWG Size - - No. Stands PVC Thickness Insulation Nylon (Mils) Thickness Jacket (Mils) Nominal O.D. (Mils) Ampacity 90 C THHN/THWN-2 Approx. Net Weight Per MFT r. I tiI 'A. • CL, Windy City 0 - 1,000 Wire standard (both ways). Other stocking put size, 1,000' RackPack ups available upon Boxes, request. with Ascending/Descending Sequential Foot Markers ®LISTED C®US LISTED MADE IN THE U.S.A.