HomeMy WebLinkAbout6221 EL CAMINO REAL; ; FA1000138/1/24, 1:43PM FA100013 Permit Data City of Carlsbad Fire Alarm Permit 6221 ELCAMINO Job Address: REAL Permit Type: FALARM Parcel No: 2131000600 Lot #: 0 Permit No: FAI 00013 Status: ISSUED Applied 3/22/2010 Approved: Reference No.: Issued: PC #: Inspector: Project Title: ZIMMER DENTAL T.I. FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: STANLEY CONVERGENT SECURITY SOLUTIONS, INC. #100 5625 RUFFIN RD SAN DIEGO, CA 858-627-4813 Owner: WALTON CWCA NORTHPOINTE 76 LLC C/O CTMT-WALTON RE TAX 4678 WORLD PARKWAY CIR ST LOUIS MO Fees ($) Add'I Fees ($) Total ($) Balance ($) 125 0 125 0 about:blank 1/1 FAiow(S' ZIMMER DENTAL 6221 EL CAMINO REAL, CARLSBAD, CA Fire Alarm Submittal T.I. Submitted By: STANLEY SECURITY 5625 RUFFIN ROAD #100 San Diego, CA. 92123 Lic. CIO - 848019 ZIMMER DENTAL T.I. Fire Alarm Submittal Equipment List Description Model Manufacture CSFM# EXISTING EQUIPMENT Fire Alarm Panel 5800 Honeywell 7165-0822:124 Fire Alarm Annunciator 541R Honeywell 7165-0822:124 Smoke Detector 2412B System Sensor 7272-1209:103 Manual Pull Station BG-12 Fire-Lite 7150-0075:184 Strobe S1224MC System Sensor 7125-1209:222 Horn/Strobe P1224MC System Sensor 7135-1209:223 Connection to exist water flow Provided and installed by Others. Connection to exist tamper sw. Provided and installed by Others. Connection to exist P.I.V Switch Provided and installed by Others. NEW EQUIPMENT 3 Horn/Strobe P2R System Sensor 7125-1653:188 Lot Wire 14/2Cond. (Notification) Atlas Cable 7161-0972:100 Lot Wire 18/4Cond. (Annunciator) Atlas Cable 7161-0972:100 Lot Wire 18/2Cond. (Initiation) Atlas Cable 7161-0972:100 Lot #14 THWN Underground Cable Selectable-Output Horns, Strobes, and Horn Strobes SpectrAlertAdvance selectable-output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper resistant construction Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Reid-selectable candela settings on wall and ceiling units: 15,15/75, 30, 75, 95, 110,115,135,150,177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall and ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with existing SpectrAlert products Compatible with MDL sync module The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings GHUNG LISTED APPROV! S401 (chm. horn ,trob, horn,) 3023S72 S5512(rtrobe,) 0 MEA approved 725 1653186(Indoor,tbE,) 7 7:25- !25-1653:1(h0,n st,obes, MEA452-05-E chimernobos) 7135-1653:189 (horns. chln,e,) SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box or double-gang back box Two-wireproducts shall also mount to a single-gang 2 x 4 x 17/s-inch back box A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.CircuiC Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30 75,95,110,115,135,150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4/16 x 411/ic x 21A-inch back box The module shall also control two Style '((class B) circuits or one Style Z (class A) circuit The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. L. !L Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DE/FWR or regulated 24 DcJFWR1 Operating Voltage Range5 8 to 17.5V (12V nominal) or 16 to 33 V (24V nominal) Input Terrnin& Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8diameterx 2.5 high (173 mm diameter x 64mm high) Wall-Mount Dimensions (including lens) 5.6L x 4.7-Wx 25D (142 mm Lx 119 mmWx 64mm D) Horn Dimensions 5.6L x4.7Wx 13-D (142 mm Lx 119 mm Wx33 mm D) Wall-Mount Back Box Skirt Dimensions (Bl3S-2, BRSW-2) 5.9L x 5.0Wx 2.2D(151 mm Lx 128 mmWx 56mm D) Ceiling-Mount Beck Box Skirt Dimensions (BHSC-2, BBSCW-2) 7.1 diameterx 2.2-high (180 mm diameter x 57 mm high) Wall-Mount Trim Ring Dimensions (sold as a S pack) (TR-HS, TRW-115) 5.7Th x4.8Wx 035T (145 mm L x122 mmWx 9 m D) Ceilirrg..MourrtTrirn Ring Dimensions (sold as a Speck) (TRc-HS,TRCW-HS) 6,9diameterx 0.35-high (175 mm diameter x 9 m high) Notes: Full Wave Rectified (RNR1 voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 Cd. A05-0395-OO7 UL Current Draw Data 8-173 Volta 16-33 Volts 6-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern d8 DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 J 8-173 Volts 16-33 Volts DC Input 15 15/75 15 1 517 5 30 75 95 110 115 Temporal High 137 147 (7) 90 (10]) 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-TemporaiHigh 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-TemporalLow 132 154 80 90 105 161 184 202 211 ?TYT cr 16-33 Vots 16-33Volt DC Input 135 150 177 185 I 2R Input 13.5 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data 6-17.5 16-33 24-Volt Nomi Switch Volts Volts Reverberant An rhoic Position Sound Pattern dtr DC FWR DC FWFI DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium /4 /4 80 80 86 86 96 96 3 Temporal Low /1 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 75 Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8, and 9 are not available on 2-wire horn strobe. AO5-0395-507 SpectrAlert Advance Dimensions Wall.-mount horn strobes Cefling-i-nourst horn strobes WaR back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information WL#A.i4k Wall Horn Strobes P2Rt 2-Wire Horn Strobe, Standard cd5, Red P2RI-1 2-Wire Horn Strobe, High cd, Red P2W 2-Wire Horn Strobe, Standard cd, White P2WH 2-Wire Horn Strobe, High cd, White P4R 4-Wire Horn Strobe, Standard cd, Red P4PJ-1 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes 5t Strobe, Standard cd, Red SRH Strobe, High cd, Red SW Strobe, Standard cd, White SWH Strobe, High cd, White r:eilirrci horn Strobes PC2R 2-Wire Horn Strobe, Standard cd, Red PC2RH 2-Wire Horn Strobe, High cd, Red PC2W 2-Wire Horn Strobe, Standard cd, White PC2WW 2-Wire Horn Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red PC4RH 4-Wire Horn Strobe, High cd, Red PC4W 4-Wire Horn Strobe, Standard cd, White Ceiling Strobes SCR Strobe, Standard cd, Red SCRH Strobe, High cd, Red SCW Strobe, Standard cd, White SCWH Strobe, High cd, White Horns HR Horn, Red HW Horn, White Accessories BBS-2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White TR-HS Trim Ring, Wall, Red TRW-HS Trim Ring, Wall White TRC-HS Trim Ring, Ceiling, Red TRCW-HS Trim Ring, Ceiling, White Notes: kId -Pto model number for plain housing (noFlRE' marking on cover), e.g., P2R-P t Add -SP to model number for FUEGO marking on cover, e.g., P2R-SP. 'Standard cd'refers to strobes that include 15,15/75,30,75,95, 110, and 115 candela settings.'High cdrefers to strobes that include 135,15Q 177, and 185 candela settings. SYSEEM 3825 Ohio Avenue. St Charles, IL 60174 ©S9SCtOSOr Pt rO SfJS'OR' Phone: 800-SENSOR2 Fax: 630-3776495 fOOUO5 iig the vbnofthdsht A05-0395-007 4,9 #2132 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I i FIRE ]ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I US TING SERVICE LISTING No. 7125-1653:188 Page lof 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: System Sensor, Unincorporated Div. of Honeywell Intl Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 Fax (630) 377-7245 Trish.Linhartsystemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffice models are suitable for outdoor applications at temperatures from -40 Degrees F to +151 Degrees F (-40 Degrees C to +66 Degrees C) and are rated NEMA 4X* when used with the System Sensor weather proof back boxes models SA-WBB (Wall), *SA..WBBW (Wall), SA-WBBC (Ceiling) and *SA.WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8— 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired applications when used with separately listed compatible fire alarm control units. Suitable for indoor or outdoor use, ceiling or wall mount. The audible units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instruction Manual for details. "Rev. 12-01-08 bh This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division