HomeMy WebLinkAbout3182 LIONSHEAD AVE; ; FPC2019-0070PERMIT REPORT (3ity of Carlsbad Print Date: 06/10/2024 Permit No: FPC2019-0070 Job Address: 3182 LIONSHEAD AVE. CARLSBAD, CA 92010-4701 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2218801000 Track U: Applied: 03/18/2019 Valuation: $1,188,795.60 Lot U: Issued: 04/01/2019 Occupancy Group: Project #: Finaled Close Out: 02/22/2024 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check U: INSPECTOR: Wong, Cindy Plan Check U: Fieri, Dominic Project Title: Description: BERG ELECTRIC - SPRINKLER TI (193 HEADS) Applicant: FPContractor: PACIFIC FIRE SYSTEMS INC PACIFIC FIRE SYSTMES INC CRYSTAL LYONS 12316 OAK KNOLL RD, U STE A 12316 OAK KNOLL RD, U STE A POWAY, CA 92064-5364 POWAY, CA 92064-5363 (858) 722-9865 (858) 883-2333 FEE AMOUNT FIRE NFPA 13 or 13R System > 100 heads $654.00 Total Fees: $654.00 Total Payments To Date: $654.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov HYDRAULIC CALCULATIONS BERGELECTRIC T.I. 3182 LIONSHEAD AVE CARLSBAD, CA 92008 - - Fire Protection by Computer Design PACIFIC FIRE SYSTEMS, INC. 12316 OAK KNOLL RD. SUITE A P0 WAY, CA 92064 858-883-2333 Job Name : Berg Electric TI - Area 2 Drawing Location : 3182 LIONSHEAD AVE, CARLSBAD, CA Remote Area : 1 Contract Data File : Area 2.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PACIFIC FIRE SYSTEMS, INC. Page Berg Electric TI - Area 2 Date Hydraulic Design Information Sheet Name - BERGELECTRIC T.I. Date - 03-13-19 Location - 3182 LIONSHEAD AVE, CARLSBAD, CA Building - System No. - 1 Contractor - PACIFIC FIRE SYSTEMS, INC. Contract No. - Calculated By - C. LYONS Drawing No. - FP2 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - Occupancy - B AND S2 S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. (X) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E N Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .10 (X) Wet Make VIKING D Area Per Sprinkler - VARIES ( ) Dry Model VK602 E Elevation at Highest Outlet - 11'-10" ( ) Deluge Size 3/4" S Hose Allowance - Inside - 100 ( ) Preaction K-Factor 8.0 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 G Hose Allowance - Outside - N Note Based on existing calculation card residual GPM / PSI, manually peaked Calculation Flow Required - 289.650 Press Required - 36.061 Summary C-Factor Used: 120 Overhead Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - @ Press - R Residual Press - Elev. - Well Flow - Proof Flow S Elevation - U P Location - P L Source of Information Y C Commodity Class Location O Storage Ht. Area Aisle W. N Storage Method: Solid Piled % Palletized % Rack N Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C 41 PACIFIC FIRE SYSTEMS, INC. Page 2 Berg Electric TI - Area 2 Date Demand: Dl - Elevation : 4.908 D2 - System Flow : 289.65 D2 - System Pressure : 36.061 Hose ( Demand) D3 - System Demand : 289.65 Safety Margin 150 140 130 p120 R° E10° S90 s80 U70 R6° E5° 40 - ______ ________ ___________ _____________ _______________ 30 20 an w - IQi_d •.... I I I __________________________ I 50 100 150 200 250 300 350 400 450 FLOW (NA1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flbw Diagram PACIFIC FIRE SYSTEMS, INC. Berg Electric TI - Area 2 0 $6 - 6 I 69.7 34. S7 - 7 I 35.4 26. S8 -. 8 I 8.6 34.4 S9 +- 9 0 S12-. 12 I 87.1 33. S13+-. 13 I 53.2 26 . S14,- 14 I 27.2 33. S15#-. 15 6.5 33 I S16,- 16 16.8 10OT- 100 16.8 16. IOIT-+ 101 33.7 69.i 102L. 102 1 I 36 87.1 103T- 103 I 123.1 15. 104T-+ 104 1' 107.3 18. 105T-+ 105 1 I 88.6 17 I 106T-* 106 71.6 15. 107T-> 107 t I 56.1 14. 108T- 108 t I 41.5 14 109T-+ 109 t I 27.5 13. IIOT--> 110 1 I 13.7 Page 3 Date Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FIw Diagram PACIFIC FIRE SYSTEMS, INC. Berg Electric TI - Area 2 13.T IIIT+ 111 16.8 1201- 120 1 I 16.8 16. 1211- 121 I 33.7 6O. 1221-. 122 I 93.9 72. 1231-. 123 I 166.5 15. 1241-. 124 18.8 1251;-. 125 I 88.6 17 . 1261;- 126 71.6 154 127w-. 127 I 56.1 144 128 I 41.5 14 . 129 27.5 134 130 I 13.7 132 1311- 131 16.8 IOOL. 120T 16.9 1011;-. 121T 69.7 35.4 102T-*6 -*7 -8 -*9 122T 69.7 8.6 87.1 53.2 6.5 103T-* 12 -* 13 -* 14 - 15 -. 16 123T 87.1 27.2 15.8 1041;.- 124T 18.8 1057- 125T 17 1061-. 126T 15.5 1071;.. 127T Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 4 Date Flow Diagram PACIFIC FIRE SYSTEMS, INC. Page 5 Berg Electric TI - Area 2 Date 14.6 1081- 128T 14 109J-. 129T 13.8 1101-. 130T 13.7 1111-. 131T 16.8 36 107.3 71.6 41.5 13.7 100-. 101-4 102.- 1034-. 104+- 105+- 106+-- 107+- 108+- 1094- 110+-. 111 33.7 123.1 88.6 56.1 27.5 16.8 93.9 182.3 88.6 56.1 27.5 120+- 121+- 122+- 123+- 124+- SPL-+ 125-p 126-p 127-p 128-. 129-. 130-. 131 33.7 166.5 107.3 71.6 41.5 13.7 289.6 SPL+- TOR.- BOR 289.6 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary PACIFIC FIRE SYSTEMS, INC. Page 6 Berg Electric TI - Area 2 Date Fitting Legend Abbrev. Name % % 1 1,4 1% 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 139OStandardElbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 I 90' Grvd-Vic Elbow #10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 T NFPA 13 90 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Piessure / Flow Summary - STANDARD PACIFIC FIRE SYSTEMS, INC. Page 7 Berg Electric TI - Area 2 Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. S6 11.833 28.51 na S7 11.833 8 18.39 na S8 9.333 5.6 22.82 na S9 11.833 8 18.48 na S10 11.833 8 18.56 na S12 11.833 27.77 na S13 11.833 8 18.0 na S14 9.333 5.6 21.56 na S15 11.833 8 17.7 na S16 11.833 8 17.0 na S17 11.833 8 17.16 na lOOT 28.0 23.05 na 10IT 28.0 23.05 na 102T 28.0 22.45 na 103T 28.0 22.19 na 1041 28.0 23.22 na lOST 28.0 23.37 na 106T 28.0 23.45 na 107T 28.0 23.51 na 108T 28.0 23.54 na 109T 28.0 23.56 na hOT 28.0 23.57 na lilT 28.0 23.57 na 120T 28.0 23.48 na 121T 28.0 23.48 na 122T 28.0 23.11 na 123T 28.0 22.97 na 124T 28.0 23.61 na 1251 28.0 23.9 na 126T 28.0 23.89 na 127T 28.0 23.88 na 1281 28.0 23.87 na 129T 28.0 23.87 na 130T 28.0 23.87 na 131T 28.0 .23.87 na 6 28.0 21.51 na 7 28.0 21.04 na 8 28.0 20.9 na 9 28.0 20.89 na 10 28.0 21.0 na 12 28.0 20.77 na 13 28.0 20.06 na 14 28.0 19.75 na 15 28.0 19.73 na 16 28.0 19.74 na 17 28.0 19.99 na 100 26.5 23.66 na 101 26.5 23.66 na 102 26.5 23.64 na 103 26.5 23.66 na 104 26.5 23.84 na 105 26.5 23.97 na 106 26.5 24.06 na 107 26.5 24.12 na 108 26.5 24.16 na 109 26.5 24.18 na 110 26.5 24.19 na 120 26.5 24.17 na 121 26.5 24.17 na 122 26.5 24.18 na 123 26.5 24.21 na 124 26.5 24.29 na 34.31 1.0 1 17.0 26.75 0.1 225 7.0 34.4 1.0 1 17.0 34.47 1.0 1 17.0 33.94 1.0 1 17.0 26.0 0.1 225 7.0 33.66 1.0 1 10.6 32.98 1.0 1 17.0 33.14 1.0 1 17.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard PACIFIC FIRE SYSTEMS, INC. Page 8 Berg Electric TI - Area 2 Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. SPL 26.5 24.61 na 125 26.5 24.59 na 126 26.5 24.58 na 127 26.5 24.56 na 128 26.5 24.55 na 129 26.5 24.55 na 130 26.5 24.54 na TOR 26.5 24.73 na BOR 0.5 36.06 na The maximum velocity is 12.8 and it occurs in the pipe between nodes S10 and 10 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 9 Berg Electric TI - Area 2 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn S6 0.0 1.049 E 2.0 20.333 28.513 to 120.0 T 5.0 7.000 -7.002 6 0.0 0.0 0.0 27.333 0.0 Vet = 0 0.0 0.0 21.511 K Factor =0 S7 34.31 1.049 E 2.0 20.333 18.391 K Factor = 8.00 to 120.0 T 5.0 7.000 -7.002 7 34.31 0.3531 0.0 27.333 9.652 Vet = 12.74 0.0 34.31 21.041 K Factor = 7.48 S8 26.75 1.049 E 2.0 20.667 22.816 K Factor = 5.60 to 120.0 T 5.0 7.000 -8.085 8 26.75 0.2229 0.0 27.667 6.166 Vet = 9.93 0.0 26.75 20.897 K Factor = 5.85 S9 34.40 1.049 E 2.0 19.500 18.485 K Factor = 8.00 to 120.0 1 5.0 7.000 -7.002 9 34.4 0.3548 0.0 26.500 9.402 Vet = 12.77 0.0 34.40 20.885 K Factor = 7.53 S10 34.47 1.049 E 2.0 19.500 18.561 K Factor= 8.00 to 120.0 T 5.0 7.000 -7.002 10 34.47 0.3562 0.0 26.500 9.438 Vel = 12.80 0.0 34.47 20.997 K Factor = 7.52 S12 0.0 1.049 E 2.0 19.167 27.772 to 120.0 T 5.0 7.000 -7.002 12 0.0 0.0 0.0 26.167 0.001 Vel = 0 0.0 0.0 20.771 K Factor = 0 S13 33.94 1.049 E 2.0 19.167 18.002 K Factor= 8.00 to 120.0 1 5.0 7.000 -7.002 13 33.94 0.3462 0.0 26.167 9.060 Vel = 12.60 0.0 33.94 20.060 K Factor = 7.58 814 26.00 1.049 E 2.0 22.667 21.564 K Factor =5.60 to 120.0 T 5.0 7.000 -8.085 14 26.0 0.2115 0.0 29.667 6.276 Vet= 9.65 0.0 26.00 19.755 K Factor = 5.85 S15 33.66 1.049 E 2.0 19.500 17.702 K Factor = 8.00 to 120.0 T 5.0 7.000 -7.002 15 33.66 0.3409 0.0 26.500 9.034 Vet = 12.50 0.0 33.66 19.734 KFactor= 7.58 816 32.98 1.049 E 2.0 22.667 17.000 K Factor =8.00 to 120.0 T 5.0 7.000 -7.002 16 32.98 0.3284 0.0 29.667 9.742 Vel = 12.24 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 10 Berg Electric TI - Area 2 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 32.98 19.740 K Factor = 7.42 S17 33.14 1.049 E 2.0 22.667 17.161 K Factor =8.00 to 120.0 T 5.0 7.000 -7.002 17 33.14 0.3312 0.0 29.667 9.827 Vel = 12.30 0.0 33.14 19.986 K Factor = 7.41 lOOT -16.79 2.157 T 12.307 1.500 23.053 to 120.0 0.0 12.307 0.650 100 -16.79 -0.0028 0.0 13.807 -0.039 Vel = 1.47 0.0 -16.79 23.664 K Factor= -3.45 101T -16.89 2.157 T 12.307 1.500 23.049 to 120.0 0.0 12.307 0.650 101 -16.89 -0.0029 0.0 13.807 -0.040 Vel = 1.48 0.0 -16.89 23.659 K Factor= -3.47 102T 69.68 2.157 T 12.307 1.500 22.452 to 120.0 0.0 12.307 0.650 102 69.68 0.0391 0.0 13.807 0.540 Vel = 6.12 0.0 69.68 23.642 K Factor= 14.33 103T 87.14 2.157 T 12.307 1.500 22.194 to 120.0 0.0 12.307 0.650 103 87.14 0.0592 0.0 13.807 0.817 Vel = 7.65 0.0 87.14 23.661 K Factor = 17.91 104T -15.79 2.157 T 12.307 1.500 23.224 to 120.0 0.0 12.307 0.650 104 -15.79 -0.0025 0.0 13.807 -0.035 Vel = 1.39 0.0 -15.79 23.839 K Factor= -3.23 105T -18.77 2.157 T 12.307 1.500 23.368 to 120.0 0.0 12.307 0.650 105 -18.77 -0.0035 0.0 13.807 -0.048 Vel= 1.65 0.0 -18.77 23.970 K Factor= -3.83 106T -16.97 2.157 T 12.307 1.500 23.452 to 120.0 0.0 12.307 0.650 106 -16.97 -0.0029 0.0 13.807 -0.040 Vel = 1.49 0.0 -16.97 24.062 K Factor= -3.46 107T -15.52 2.157 T 12.307 1.500 23.508 to 120.0 0.0 12.307 0.650 107 -15.52 -0.0025 0.0 13.807 -0.034 Vel = 1.36 0.0 -15.52 24.124 KFactor= -3.16 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 11 Berg Electric TI - Area 2 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 108T -14.58 2.157 1 12.307 1.500 23.541 to 120.0 0.0 12.307 0.650 108 -14.58 -0.0022 0.0 13.807 -0.030 Vel 1.28 0.0 -14.58 24.161 K Factor= -2.97 109T -14.03 2.157 T 12.307 1.500 23.560 to 120.0 0.0 12.307 0.650 109 -14.03 -0.0020 0.0 13.807 -0.028 VeI= 1.23 0.0 -14.03 24.182 K Factor= -2.85 11 OT -13.77 2.157 T 12.307 1.500 23.569 to 120.0 0.0 12.307 0.650 110 -13.77 -0.0020 0.0 13.807 -0.027 VeI= 1.21 0.0 -13.77 24.192 K Factor= -2.80 lilT -13.70 2.157 T 12.307 1.500 23.572 to 120.0 0.0 12.307 11.838 111 -13.7 -0.0020 0.0 13.807 -0.027 VeI= 1.20 0.0 -13.70 35.383 K Factor= -2.30 120T 16.79 2.157 T 12.307 1.500 23.482 to 120.0 0.0 12.307 0.650 120 16.79 0.0028 0.0 13.807 0.038 Vel = 1.47 0.0 16.79 24.170 K Factor= 3.42 121T 16.89 2.157 T 12.307 1.500 23.483 to 120.0 0.0 12.307 0.650 121 16.89 0.0028 0.0 13.807 0.039 Vel = 1.48 0.0 16.89 24.172 K Factor 3.44 122T 60.24 2.157 T 12.307 1.500 23.114 to 120.0 0.0 12.307 0.650 122 60.24 0.0298 0.0 13.807 0.412 Vel = 5.29 0.0 60.24 24.176 K Factor= 12.25 123T 72.59 2.157 1 12.307 1.500 22.975 to 120.0 0.0 12.307 0.650 123 72.59 0.0422 0.0 13.807 0.582 Vel = 6.37 0.0 72.59 24.207 K Factor= 14.75 124T 15.79 2.157 1 12.307 1.500 23.607 to 120.0 0.0 12.307 0.650 124 15.79 0.0025 0.0 13.807 0.035 Vel = 1.39 0.0 15.79 24.292 K Factor = 3.20 125T 18.77 2.157 T 12.307 1.500 23.896 to 120.0 0.0 12.307 0.650 125 18.77 0.0034 0.0 13.807 0.047 Vel= 1.65 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 12 Berg Electric TI - Area 2 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. I.G. or Ftng's Pe Pv Notes ****** Point Qt PfIFt Eqv. Ln. Total Pf Pn 0.0 18.77 24.593 KFactor= 3.78 126T 16.97 2.157 T 12.307 1.500 23.890 to 120.0 0.0 12.307 0.650 126 16.97 0.0028 0.0 13.807 0.039 Vel = 1.49 0.0 16.97 24.579 K Factor= 3.42 1271 15.52 2.157 T 12.307 1.500 23.879 to 120.0 0.0 12.307 0.650 127 15.52 0.0024 0.0 13.807 0.033 Vel = 1.36 0.0 15.52 24.562 K Factor= 3.13 128T 14.58 2.157 T 12.307 1.500 23.872 to 120.0 0.0 12.307 0.650 128 14.58 0.0022 0.0 13.807 0.030 Vel = 1.28 0.0 14.58 24.552 KFactor= 2.94 129T 14.03 2.157 T 12.307 1.500 23.868 to 120.0 0.0 12.307 0.650 129 14.03 0.0020 0.0 13.807 0.028 Vel = 1.23 0.0 14.03 24.546 K Factor = 2.83 130T 13.77 2.157 T 12.307 1.500 23.867 to 120.0 0.0 12.307 0.650 130 13.77 0.0019 0.0 13.807 0.026 Vel = 1.21 0.0 13.77 24.543 K Factor= 2.78 131T 13.70 2.157 T 12.307 1.500 23.866 to 120.0 0.0 12.307 11.838 131 13.7 0.0020 0.0 13.807 0.027 Vel = 1.20 0.0 13.70 35.731 K Factor = 2.29 lOOT 16.79 2.157 21 24.613 128.000 23.053 to 120.0 0.0 24.613 0.0 120T 16.79 0.0028 0.0 152.613 0.429 Vel = 1.47 0.0 16.79 23.482 K Factor = 3.46 101T 16.89 2.157 2T 24.613 128.000 23.049 to 120.0 0.0 24.613 0.0 121T 16.89 0.0028 0.0 152.613 0.434 Vel= 1.48 0.0 16.89 23.483 K Factor = 3.49 102T -69.68 2.157 T 12.307 11.750 22.452 to 120.0 0.0 12.307 0.0 6 -69.68 -0.0391 0.0 24.057 -0.941 Vel = 6.12 6 0.0 2.157 0.0 12.000 21.511 to 120.0 0.0 0.0 0.0 7 -69.68 -0.0392 0.0 12.000 -0.470 Vel = 6.12 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fiial Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 13 Berg Electric TI - Area 2 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 7 34.31 2.157 0.0 12.875 21.041 to 120.0 0.0 0.0 0.0 8 -35.37 -0.0112 0.0 12.875 -0.144 Vel = 3.11 8 26.75 2.157 0.0 14.875 20.897 to 120.0 0.0 0.0 0.0 9 -8.62 -0.0008 0.0 14.875 -0.012 Vel = 0.76 9 34.40 2.157 0.0 18.000 20.885 to 120.0 0.0 0.0 0.0 10 25.78 0.0062 0.0 18.000 0.112 Vel = 2.26 10 34.46 2.157 T 12.307 58.500 20.997 to 120.0 0.0 12.307 0.0 1221 60.24 0.0299 0.0 70.807 2.117 Vet= 5.29 0.0 60.24 23.114 KFactor= 12.53 1031 -87.14 2.157 T 12.307 11.750 22.194 to 120.0 0.0 12.307 0.0 12 -87.14 -0.0592 0.0 24.057 -1.423 Vel = 7.65 12 0.0 2.157 0.0 12.000 20.771 to 120.0 0.0 0.0 0.0 13 -87.14 -0.0592 0.0 12.000 -0.711 VeI= 7.65 13 33.94 2.157 0.0 12.875 20.060 to 120.0 0.0 0.0 0.0 14 -53.2 -0.0237 0.0 12.875 -0.305 Vet = 4.67 14 26.01 2.157 0.0 3.000 19.755 to 120.0 0.0 0.0 0.0 15 -27.19 -0.0070 0.0 3.000 -0.021 Vet = 2.39 15 33.66 2.157 0.0 11.875 19.734 to 120.0 0.0 0.0 0.0 16 6.47 0.0005 0.0 11.875 0.006 Vet = 0.57 16 32.98 2.157 0.0 18.000 19.740 to 120.0 0.0 0.0 0.0 17 39.45 0.0137 0.0 18.000 0.246 Vet = 3.46 17 33.14 2.157 1 12.307 58.500 19.986 to 120.0 0.0 12.307 0.0 1231 72.59 0.0422 0.0 70.807 2.989 Vet = 6.37 0.0 72.59 22.975 KFactor= 15.14 1041 15.79 2.157 2T 24.613 128.000 23.224 to 120.0 0.0 24.613 0.0 1241 15.79 0.0025 0.0 152.613 0.383 Vel = 1.39 0.0 15.79 23.607 K Factor= 3.25 105T 18.77 2.157 21 24.613 128.000 23.368 to 120.0 0.0 24.613 0.0 125T 18.77 0.0035 0.0 152.613 0.528 Vel = 1.65 0.0 18.77 23.896 K Factor = 3.84 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Filial Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 14 Berg Electric TI - Area 2 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. .1C11 or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 106T 16.97 2.157 2T 24.613 128.000 23.452 to 120.0 0.0 24.613 0.0 126T 16.97 0.0029 0.0 152.613 0.438 Vel= 1.49 0.0 16.97 23.890 K Factor = 3.47 107T 15.52 2.157 2T 24.613 128.000 23.508 to 120.0 0.0 24.613 0.0 127T 15.52 0.0024 0.0 152.613 0.371 VeI= 1.36 0.0 15.52 23.879 KFactor= 3.18 108T 14.58 2.157 2T 24.613 128.000 23.541 to 120.0 0.0 24.613 0.0 128T 14.58 0.0022 0.0 152.613 0.331 VeI= 1.28 0.0 14.58 23.872 K Factor = 2.98 109T 14.03 2.157 2T 24.613 128.000 23.560 to 120.0 0.0 24.613 0.0 129T 14.03 0.0020 0.0 152.613 0.308 Vel = 1.23 0.0 14.03 23.868 K Factor = 2.87 11 OT 13.77 2.157 2T 24.613 128.000 23.569 to 120.0 0.0 24.613 0.0 130T 13.77 0.0020 0.0 152.613 0.298 Vel = 1.21 0.0 13.77 23.867 K Factor = 2.82 lilT 13.70 2.157 21 24.613 128.000 23.572 to 120.0 0.0 24.613 0.0 131T 13.7 0.0019 0.0 152.613 0.294 Vel = 1.20 0.0 13.70 23.866 K Factor = 2.80 100 -16.79 3.26 0.0 12.500 23.664 to 120.0 0.0 0.0 0.0 101 -16.79 -0.0004 0.0 12.500 -0.005 Vel = 0.65 101 -16.89 3.26 0.0 12.500 23.659 to 120.0 0.0 0.0 0.0 102 -33.68 -0.0014 0.0 12.500 -0.017 VeI= 1.29 102 69.68 3.26 0.0 12.500 23.642 to 120.0 0.0 0.0 0.0 103 36.0 0.0015 0.0 12.500 0.019 Vel = 1.38 103 87.14 3.26 0.0 11.833 23.661 to 120.0 0.0 0.0 0.0 104 123.14 0.0150 0.0 11.833 0.178 VeI= 4.73 104 -15.79 3.26 0.0 11.250 23.839 to 120.0 0.0 0.0 0.0 105 107.35 0.0116 0.0 11.250 0.131 VeI= 4.13 105 -18.77 3.26 0.0 11.250 23.970 to 120.0 0.0 0.0 0.0 106 88.58 0.0082 0.0 11.250 0.092 Vel = 3.40 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 15 Berg Electric TI - Area 2 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 106 -16.97 3.26 0.0 11.250 24.062 to 120.0 0.0 0.0 0.0 107 71.61 0.0055 0.0 11.250 0.062 Vel= 2.75 107 -15.52 3.26 0.0 10.667 24.124 to 120.0 0.0 0.0 0.0 108 56.09 0.0035 0.0 10.667 0.037 Vel = 2.16 108 -14.58 3.26 0.0 10.500 24.161 to 120.0 0.0 0.0 0.0 109 41.51 0.0020 0.0 10.500 0.021 Vel = 1.60 109 -14.04 3.26 0.0 10.500 24.182 to 120.0 0.0 0.0 0.0 110 27.47 0.0010 0.0 10.500 0.010 Vel = 1.06 110 -13.77 3.26 0.0 10.500 24.192 to 120.0 0.0 0.0 11.188 111 13.7 0.0003 0.0 10.500 0.003 Vel = 0.53 0.0 13.70 35.383 K Factor = 2.30 120 16.79 4.26 0.0 12.500 24.170 to 120.0 0.0 0.0 0.0 121 16.79 0.0002 0.0 12.500 0.002 Vel = 0.38 121 16.89 4.26 0.0 12.500 24.172 to 120.0 0.0 0.0 0.0 122 33.68 0.0003 0.0 12.500 0.004 Vel = 0.76 122 60.24 4.26 0.0 12.500 24.176 to 120.0 0.0 0.0 0.0 123 93.92 0.0025 0.0 12.500 0.031 Vel = 2.11 123 72.59 4.26 0.0 11.833 24.207 to 120.0 0.0 0.0 0.0 124 166.51 0.0072 0.0 11.833 0.085 Vel= 3.75 124 15.79 4.26 T 26.334 11.250 24.292 to 120.0 0.0 26.334 0.0 SPL 182.3 0.0084 0.0 37.584 0.316 Vel = 4.10 SPL -289.65 4.26 0.0 4.917 24.608 to 120.0 0.0 0.0 0.0 125 -107.35 -0.0031 0.0 4.917 -0.015 Vel = 2.42 125 18.77 4.26 0.0 6.333 24.593 to 120.0 0.0 0.0 o:o 126 -88.58 -0.0022 0.0 6.333 -0.014 Vel = 1.99 126 16.97 4.26 0.0 11.250 24.579 to 120.0 0.0 0.0 0.0 127 -71.61 -0.0015 0.0 11.250 -0.017 Vel = 1.61 127 15.52 4.26 0.0 10.667 24.562 to 120.0 0.0 0.0 0.0 128 -56.09 -0.0009 0.0 10.667 -0.010 Vel = 1.26 128 14.58 4.26 0.0 10.500 24.552 to 120.0 0.0 0.0 0.0 129 -41.51 -0.0006 0.0 10.500 -0.006 Vel = 0.93 129 14.04 4.26 0.0 10.500 24.546 to 120.0 0.0 0.0 0.0 130 -27.47 -0.0003 0.0 10.500 -0.003 Vel = 0.62 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fiial Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 16 Berg Electric TI - Area 2 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 130 13.77 4.26 0.0 10.500 24.543 to 120.0 0.0 0.0 11.188 131 -13.7 0.0 0.0 10.500 0.0 Vel = 0.31 0.0 -13.70 35.731 K Factor= -2.29 SPL 289.65 6.357 21 25.147 16.875 24.608 to 120.0 0.0 25.147 0.0 TOR 289.65 0.0028 0.0 42.022 0.119 VeI= 2.93 TOR 0.0 6.357 0.0 26.000 24.727 to 120.0 0.0 0.0 11.261 BOR 289.65 0.0028 0.0 26.000 0.073 Vel = 2.93 0.0 289.65 36.061 K Factor= 48.23 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fire Protection by Computer Design PACIFIC FIRE SYSTEMS, INC. 12316 OAK KNOLL RD. SUITE A POWAY, CA 92064 858-883-2333 Job Name Berg Electric TI - Area 1 Drawing : AREA 1 Location 3182 LIONSHEAD AVE, CARLSBAD, CA Remote Area : 1 Contract Data File Area 1 .WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PACIFIC FIRE SYSTEMS, INC. Page Berg Electric TI - Area 1 Date Hydraulic Design Information Sheet Name - BERGELECTRIC T.I. Date - 03-13-19 Location - 3182 LIONSHEAD AVE. CARLSBAD, CA Building - AREA 1 System No. - 1 Contractor - PACIFIC FIRE SYSTEMS, INC. Contract No. - Calculated By - C. LYONS Drawing No. - FP2 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - Occupancy - B AND S2 (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. (X) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. NFPA 231 ( ) NFPA 231C Figure Curve Other Specific Ruling Made By Date Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .10 (X) Wet Make VIKING Area Per Sprinkler - VARIES ( ) Dry Model VK602 Elevation at Highest Outlet - 11'-10" ( ) Deluge Size 3/4" Hose Allowance - Inside - 100 ( ) Preaction K-Factor 8.0 Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 Hose Allowance - Outside - Note Based on existing calculation card residual GPM / PSI, manually peaked Calculation Flow Required - 589.584 Press Required - 35.828 Summary C-Factor Used: 120 Overhead Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - @ Press - R Residual Press - Elev. - Well Flow - Proof Flow S Elevation - U P Location - P L Source of Information - Y C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack N Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row C ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: S Y S T E M D E S I G N Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C PACIFIC FIRE SYSTEMS, INC. Page 2 Berg Electric TI - Area 1 Date Demand: Dl - Elevation : 4.908 D2 - System Flow : 289.584 D2 - System Pressure : 35.828 Hose ( Demand) D3 - System Demand : 289.584 Safety Margin 150 140 130 p120 R0 E10° S90 s 80 u 70 R6° E5° 40 - ______ ________ ___________ _____________ _______________ 30 20 In 'U 1 I I I 50 100 150 200 250 300 350 400 450 FLOW( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram PACIFIC FIRE SYSTEMS, INC. Page 3 Berg Electric TI - Area 1 Date 34.2 S6 - 6 I 41.1 34.1 ST - 7 I 6.9 26.Z S8-8 1 I 19.7 34. $9 - 9 33.9 12 60.4 33.i 13 26.7 25. S144- 14 0.8 33. S154-. 15 -r I 32.8 33 I S16,- 16 19 IOOT-* 100 19 19.. bIT-> 101 38.2 75. 1021- 102 t 37.1 1031-. 103 1- I 131.5 17j 1041:4 104 1 I 113.8 19. 105T-* 105 t I 93.9 18 I 1061:.> 106 t I 75.9 16.f 1071:-> 107 1 I 59.4 15. 1081:-> 108 1 I 44 14. 1091:-> 109 -r I 29.1 14. 1101:-> 110 f 14.5 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fkw Diagram PACIFIC FIRE SYSTEMS, INC. Page 4 Berg Electric TI - Area 1 Date 14. 111W- 111 19 120W- 120 f 19 19. 121W- 121 I 38.2 54. 122W-. 122 t 92.3 65. 123W- 123 t I 158.1 17j 124W- 124 19.9 125W- 125 93.9 18 4. 126W-. 126 75.9 16.4 127W- 127 59.4 154 128W- 128 I 44 144 129W-. 129 I 29.1 144 130W- 130 14.5 144 131W-. 131 19 100W- 120T 19.2 101W- 121T 75.3 6.9 54.1 102W- 6 -* 7 .-+ 8 +-. 9 - 122T 41.1 19.7 94.4 26.7 32.8 103W- 12 -* 13 -* 14 .-+ 15 - 16 - 123T 60.4 0.8 65.8 17.7 104W- 124T 19.9 105W- 125T 18 106W- 126T 16.4 107W- 127T Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FIw Diagram PACIFIC FIRE SYSTEMS, INC. Berg Electric TI - Area 1 15.5 100- 128T 14.9 109w- 129T 14.6 1107_. 130T 14.5 111w-. 131T Page 5 Date 19 37.1 113.8 75.9 44 14.5 100-+ 101-* 102+- 103- 104+- 105+- 106+- 107+-. 108+-. 109+-. 110+- III 38.2 131.5 93.9 59.4 29.1 19 92.3 175.8 93.9 59.4 29.1 120+-- 121+- 122~-. 123+- 124+-. SPL-+ 125- 126-~ 127-+ 128-+ 129-* 130-+ 131 38.2 158.1 113.8 75.9 44 14.5 289.6 SPL+- TOR~- BOR 289.6 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary PACIFIC FIRE SYSTEMS, INC. Page 6 Berg Electric TI - Area 1 Date Fitting Legend Abbrev. Name % % 1 1% 1% 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 90' Grvd-Vic Elbow #10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 T NFPA 1390' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD PACIFIC FIRE SYSTEMS, INC. Page 7 Berg Electric TI - Area 1 Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. S6 11.833 8 18.32 na 34.24 1.0 1 10.6 S7 11.833 8 18.2 na 34.13 1.0 1 17.0 S8 9.333 5.6 22.7 na 26.68 0.1 225 7.0 S9 11.833 8 18.43 na 34.35 1.0 1 17.0 S12 11.833 8 18.01 na 33.95 1.0 1 10.6 S13 11.833 8 17.76 na 33.72 1.0 1 17.0 S14 9.333 5.6 21.46 na 25.94 0.1 225 7.0 S15 11.833 8 17.63 na 33.59 1.0 1 10.6 S16 11.833 8 17.0 na 32.98 1.0 1 17.0 lOOT 28.0 22.72 na 101T 28.0 22.72 na 102T 28.0 22.02 na 103T 28.0 21.72 na 1041 28.0 22.91 na lOST 28.0 23.07 na 106T 28.0 23.16 na 107T 28.0 23.22 na 108T 28.0 23.26 na 109T 28.0 23.28 na hOT 28.0 23.29 na lIlT 28.0 23.29 na 1201 28.0 23.27 na 1211 28.0 23.27 na 1221 28.0 22.98 na 1231 28.0 22.87 na 1241 28.0 23.39 na 1251 28.0 23.65 na 1261 28.0 23.65 na 1271 28.0 23.64 na 1281 28.0 23.63 na 1291 28.0 23.62 na 1301 28.0 23.62 na 1311 28.0 23.62 na 6 28.0 20.94 na 7 28.0 20.76 na 8 28.0 20.75 na 9 28.0 20.81 na 12 28.0 20.07 na 13 28.0 19.71 na 14 28.0 19.62 na 15 28.0 19.62 na 16 28.0 19.74 na 100 26.5 23.32 na 101 26.5 23.32 na 102 26.5 23.3 na 103 26.5 23.32 na 104 26.5 23.52 na 105 26.5 23.66 na 106 26.5 23.77 na 107 26.5 23.84 na 108 26.5 23.88 na 109 26.5 23.9 na 110 26.5 23.91 na 120 26.5 23.96 na 121 26.5 23.97 na 122 26.5 23.97 na 123 26.5 24.0 na 124 26.5 24.08 na SPL 26.5 24.37 na 125 26.5 24.36 na 126 26.5 24.34 na 127 26.5 24.32 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard PACIFIC FIRE SYSTEMS, INC. Page 8 Berg Electric TI - Area 1 Date Node No. Elevation K-Fact Pt Actual Pn Flow Density Area Press Actual Req. 128 26.5 24.31 na 129 26.5 24.31 na 130 26.5 24.3 na TOR 26.5 24.49 na BOR 0.5 35.83 na The maximum velocity is 12.75 and it occurs in the pipe between nodes S9 and 9 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 9 Berg Electric TI - Area 1 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn S6 34.24 1.049 E 2.0 20.333 18.320 K Factor= 8.00 to 120.0 T 5.0 7.000 -7.002 6 34.24 0.3519 0.0 27.333 9.618 Vel = 12.71 0.0 34.24 20.936 K Factor = 7.48 S7 34.13 1.049 E 2.0 20.333 18.201 K Factor = 8.00 to 120.0 T 5.0 7.000 -7.002 7 34.13 0.3498 0.0 27.333 9.561 Vel = 12.67 0.0 34.13 20.760 K Factor = 7.49 S8 26.68 1.049 E 2.0 20.667 22.701 K Factor = 5.60 to 120.0 T 5.0 7.000 -8.085 8 26.68 0.2218 0.0 27.667 6.137 Vel = 9.90 0.0 26.68 20.753 K Factor = 5.86 S9 34.35 1.049 E 2.0 19.500 18.433 K Factor = 8.00 to 120.0 T 5.0 7.000 -7.002 9 34.35 0.3539 0.0 26.500 9.378 Vel = 12.75 0.0 34.35 20.809 K Factor = 7.53 S12 33.95 1.049 E 2.0 19.167 18.009 K Factor =8.00 to 120.0 T 5.0 7.000 -7.002 12 33.95 0.3464 0.0 26.167 9.064 Vel = 12.60 0.0 33.95 20.071 K Factor = 7.58 S13 33.72 1.049 E 2.0 19.167 17.763 K Factor =8.00 to 120.0 T 5.0 7.000 -7.002 13 33.72 0.3420 0.0 26.167 8.949 Vel = 12.52 0.0 33.72 19.710 K Factor = 7.60 S14 25.94 1.049 E 2.0 22.667 21.462 K Factor = 5.60 to 120.0 T 5.0 7.000 -8.085 14 25.94 0.2106 0.0 29.667 6.247 Vel = 9.63 0.0 25.94 19.624 K Factor= 5.86 S15 33.59 1.049 E 2.0 19.500 17.628 K Factor =8.00 to 120.0 1 5.0 7.000 -7.002 15 33.59 0.3395 0.0 26.500 8.998 Vel = 12.47 0.0 33.59 19.624 K Factor= 7.58 S16 32.98 1.049 E 2.0 22.667 17.000 K Factor =8.00 to 120.0 T 5.0 7.000 -7.002 16 32.98 0.3284 0.0 29.667 9.742 Vel = 12.24 0.0 32.98 19.740 K Factor = 7.42 lOOT -19.04 2.157 T 12.307 1.500 22.724 to 120.0 0.0 12.307 0.650 100 -19.04 -0.0035 0.0 13.807 -0.049 Vel = 1.67 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Firal Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 10 Berg Electric TI - Area 1 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. I.G. or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 -19.04 23.325 K Factor = -3.94 1011 -19.16 2.157 T 12.307 1.500 22.719 to 120.0 0.0 12.307 0.650 101 -19.16 -0.0036 0.0 13.807 -0.050 Vel = 1.68 0.0 -19.16 23.319 KFactor= -3.97 102T 75.31 2.157 T 12.307 1.500 22.024 to 120.0 0.0 12.307 0.650 102 75.31 0.0451 0.0 13.807 0.623 Vel = 6.61 0.0 75.31 23.297 K Factor = 15.60 1031 94.38 2.157 1 12.307 1.500 21.721 to 120.0 0.0 12.307 0.650 103 94.38 0.0686 0.0 13.807 0.947 Vel = 8.29 0.0 94.38 23.318 K Factor = 19.54 104T -17.72 2.157 T 12.307 1.500 22.911 to 120.0 0.0 12.307 0.650 104 -17.72 -0.0031 0.0 13.807 -0.043 Vel = 1.56 0.0 -17.72 23.518 K Factor = -3.65 105T -19.89 2.157 T 12.307 1.500 23.068 to 120.0 0.0 12.307 0.650 105 -19.89 -0.0039 0.0 13.807 -0.054 Vel = 1.75 0.0 -19.89 23.664 K Factor= -4.09 106T -17.98 2.157 1 12.307 1.500 23.161 to 120.0 0.0 12.307 0.650 106 -17.98 -0.0033 0.0 13.807 -0.045 Vel = 1.58 0.0 -17.98 23.766 K Factor = -3.69 1071 -16.45 2.157 T 12.307 1.500 23.223 to 120.0 0.0 12.307 0.650 107 -16.45 -0.0028 0.0 13.807 -0.038 Vel= 1.44 0.0 -16.45 23.835 K Factor = -3.37 108T -15.46 2.157 T 12.307 1.500 23.261 to 120.0 0.0 12.307 0.650 108 -15.46 -0.0025 0.0 13.807 -0.034 Vel = 1.36 0.0 -15.46 23.877 K Factor= -3.16 109T -14.87 2.157 1 12.307 1.500 23.282 to 120.0 0.0 12.307 0.650 109 -14.87 -0.0023 0.0 13.807 -0.032 Vel = 1.31 0.0 -14.87 23.900 K Factor = -3.04 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 11 Berg Electric TI - Area 1 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn hOT -14.60 2.157 T 12.307 1.500 23.292 to 120.0 0.0 12.307 0.650 110 -14.6 -0.0022 0.0 13.807 -0.031 Vel = 1.28 0.0 -14.60 23.911 K Factor= -2.99 lilT -14.52 2.157 T 12.307 1.500 23.294 to 120.0 0.0 12.307 11.838 111 -14.52 -0.0021 0.0 13.807 -0.029 VeI= 1.27 0.0 -14.52 35.103 K Factor= -2.45 120T 19.04 2.157 T 12.307 1.500 23.266 to 120.0 0.0 12.307 0.650 120 19.04 0.0035 0.0 13.807 0.048 Vel = 1.67 0.0 19.04 23.964 K Factor= 3.89 121T 19.16 2.157 T 12.307 1.500 23.267 to 120.0 0.0 12.307 0.650 121 19.16 0.0035 0.0 13.807 0.049 VeI= 1.68 0.0 19.16 23.966 K Factor = 3.91 122T 54.09 2.157 T 12.307 1.500 22.984 to 120.0 0.0 12.307 0.650 122 54.09 0.0245 0.0 13.807 0.338 Vel = 4.75 0.0 54.09 23.972 KFactor= 11.05 123T 65.81 2.157 T 12.307 1.500 22.866 to 120.0 0.0 12.307 0.650 123 65.81 0.0352 0.0 13.807 0.486 Vel = 5.78 0.0 65.81 24.002 K Factor= 13.43 124T 17.72 2.157 T 12.307 1.500 23.386 to 120.0 0.0 12.307 0.650 124 17.72 0.0030 0.0 13.807 0.042 Vel = 1.56 0.0 17.72 24.078 K Factor = 3.61 125T 19.89 2.157 T 12.307 1.500 23.655 to 120.0 0.0 12.307 0.650 125 19.89 0.0038 0.0 13.807 0.053 Vel = 1.75 0.0 19.89 24.358 KFactor= 4.03 126T 17.98 2.157 T 12.307 1.500 23.648 to 120.0 0.0 12.307 0.650 126 17.98 0.0032 0.0 13.807 0.044 VeI= 1.58 0.0 17.98 24.342 K Factor = 3.64 127T 16.45 2.157 T 12.307 1.500 23.636 to 120.0 0.0 12.307 0.650 127 16.45 0.0027 0.0 13.807 0.037 Vel = 1.44 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 12 Berg Electric TI - Area 1 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. I.G. or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 16.45 24.323 K Factor = 3.34 128T 15.46 2.157 T 12.307 1.500 23.629 to 120.0 0.0 12.307 0.650 128 15.46 0.0024 0.0 13.807 0.033 Vel = 1.36 0.0 15.46 24.312 KFactor= 3.14 1291 14.87 2.157 T 12.307 1.500 23.625 to 120.0 0.0 12.307 0.650 129 14.87 0.0022 0.0 13.807 0.031 Vel = 1.31 0.0 14.87 24.306 K Factor = 3.02 1301 14.60 2.157 T 12.307 1.500 23.623 to 120.0 0.0 12.307 0.650 130 14.6 0.0021 0.0 13.807 0.029 Vel = 1.28 0.0 14.60 24.302 K Factor = 2.96 1311 14.52 2.157 T 12.307 1.500 23.622 to 120.0 0.0 12.307 11.838 131 14.52 0.0022 0.0 13.807 0.030 Vel = 1.27 0.0 14.52 35.490 K Factor = 2.44 lOOT 19.04 2.157 21 24.613 128.000 22.724 to 120.0 0.0 24.613 0.0 1201 19.04 0.0036 0.0 152.613 0.542 Vel = 1.67 0.0 19.04 23.266 K Factor = 3.95 1011 19.16 2.157 2T 24.613 128.000 22.719 to 120.0 0.0 24.613 0.0 1211 19.16 0.0036 0.0 152.613 0.548 Vel= 1.68 0.0 19.16 23.267 K Factor = 3.97 1021 -75.31 2.157 T 12.307 11.750 22.024 to 120.0 0.0 12.307 0.0 6 -75.31 -0.0452 0.0 24.057 -1.088 Vel = 6.61 6 34.24 2.157 0.0 12.000 20.936 to 120.0 0.0 0.0 0.0 7 -41.07 -0.0147 0.0 12.000 -0.176 Vel = 3.61 7 34.13 2.157 0.0 12.875 20.760 to 120.0 0.0 0.0 0.0 8 -6.94 -0.0005 0.0 12.875 -0.007 Vel = 0.61 8 26.68 2.157 0.0 14.875 20.753 to 120.0 0.0 0.0 0.0 9 19.74 0.0038 0.0 14.875 0.056 Vel = 1.73 9 34.35 2.157 1 12.307 76.500 20.809 to 120.0 0.0 12.307 0.0 122T 54.09 0.0245 0.0 88.807 2.175 Vel = 4.75 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 13 Berg Electric TI - Area 1 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 54.09 22.984 KFactor= 11.28 103T -94.38 2.157 T 12.307 11.750 21.721 to 120.0 0.0 12.307 0.0 12 -94.38 -0.0686 0.0 24.057 -1.650 Vel = 8.29 12 33.95 2.157 0.0 12.000 20.071 to 120.0 0.0 0.0 0.0 13 -60.43 -0.0301 0.0 12.000 -0.361 Vel = 5.31 13 33.72 2.157 0.0 12.875 19.710 to 120.0 0.0 0.0 0.0 14 -26.71 -0.0067 0.0 12.875 -0.086 Vel = 2.35 14 25.94 2.157 0.0 3.000 19.624 to 120.0 0.0 0.0 0.0 15 -0.77 0.0 0.0 3.000 0.0 Vel = 0.07 15 33.59 2.157 0.0 11.875 19.624 to 120.0 0.0 0.0 0.0 16 32.82 0.0098 0.0 11.875 0.116 Vel = 2.88 16 32.99 2.157 T 12.307 76.500 19.740 to 120.0 0.0 12.307 0.0 123T 65.81 0.0352 0.0 88.807 3.126 Vel = 5.78 0.0 65.81 22.866 KFactor= 13.76 104T 17.72 2.157 2T 24.613 128.000 22.911 to 120.0 0.0 24.613 0.0 124T 17.72 0.0031 0.0 152.613 0.475 Vel = 1.56 0.0 17.72 23.386 K Factor = 3.66 105T 19.89 2.157 2T 24.613 128.000 23.068 to 120.0 0.0 24.613 0.0 125T 19.89 0.0038 0.0 152.613 0.587 Vel = 1.75 0.0 19.89 23.655 K Factor = 4.09 106T 17.98 2.157 2T 24.613 128.000 23.161 to 120.0 0.0 24.613 0.0 126T 17.98 0.0032 0.0 152.613 0.487 Vel= 1.58 0.0 17.98 23.648 K Factor= 3.70 107T 16.45 2.157 2T 24.613 128.000 23.223 to 120.0 0.0 24.613 0.0 127T 16.45 0.0027 0.0 152.613 0.413 Vel= 1.44 0.0 16.45 23.636 K Factor= 3.38 108T 15.46 2.157 2T 24.613 128.000 23.261 to 120.0 0.0 24.613 0.0 128T 15.46 0.0024 0.0 152.613 0.368 Vel = 1.36 0.0 15.46 23.629 K Factor= 3.18 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 14 Berg Electric TI - Area 1 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1091 14.87 2.157 2T 24.613 128.000 23.282 to 120.0 0.0 24.613 0.0 1291 14.87 0.0022 0.0 152.613 0.343 Vel = 1.31 0.0 14.87 23.625 K Factor = 3.06 11 OT 14.60 2.157 2T 24.613 128.000 23.292 to 120.0 0.0 24.613 0.0 130T 14.6 0.0022 0.0 152.613 0.331 Vel = 1.28 0.0 14.60 23.623 K Factor= 3.00 1111 14.52 2.157 2T 24.613 128.000 23.294 to 120.0 0.0 24.613 0.0 131T 14.52 0.0021 0.0 152.613 0.328 Vel = 1.27 0.0 14.52 23.622 K Factor = 2.99 100 -19.04 3.26 0.0 12.500 23.325 to 120.0 0.0 0.0 0.0 101 -19.04 -0.0005 0.0 12.500 -0.006 Vel = 0.73 101 -19.17 3.26 0.0 12.500 23.319 to 120.0 0.0 0.0 0.0 102 -38.21 -0.0018 0.0 12.500 -0.022 Vel = 1.47 102 75.32 3.26 0.0 12.500 23.297 to 120.0 0.0 0.0 0.0 103 37.11 0.0017 0.0 12.500 0.021 Vel = 1.43 103 94.38 3.26 0.0 11.833 23.318 to 120.0 0.0 0.0 0.0 104 131.49 0.0169 0.0 11.833 0.200 VeI= 5.05 104 -17.73 3.26 0.0 11.250 23.518 to 120.0 0.0 0.0 0.0 105 113.76 0.0130 0.0 11.250 0.146 Vel= 4.37 105 -19.89 3.26 0.0 11.250 23.664 to 120.0 0.0 0.0 0.0 106 93.87 0.0091 0.0 11.250 0.102 Vel= 3.61 106 -17.98 3.26 0.0 11.250 23.766 to 120.0 0.0 0.0 0.0 107 75.89 0.0061 0.0 11.250 0.069 Vel = 2.92 107 -16.45 3.26 0.0 10.667 23.835 to 120.0 0.0 0.0 0.0 108 59.44 0.0039 0.0 10.667 0.042 Vel = 2.28 108 -15.45 3.26 0.0 10.500 23.877 to 120.0 0.0 0.0 0.0 109 43.99 0.0022 0.0 10.500 0.023 Vel = 1.69 109 -14.88 3.26 0.0 10.500 23.900 to 120.0 0.0 0.0 0.0 110 29.11 0.0010 0.0 10.500 0.011 VeI= 1.12 110 -14.59 3.26 0.0 10.500 23.911 to 120.0 0.0 0.0 11.188 111 14.52 0.0004 0.0 10.500 0.004 VeI= 0.56 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams * PACIFIC FIRE SYSTEMS, INC. Page 15 Berg Electric TI - Area 1 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 14.52 35.103 K Factor = 2.45 120 19.04 4.26 0.0 12.500 23.964 to 120.0 0.0 0.0 0.0 121 19.04 0.0002 0.0 12.500 0.002 Vel = 0.43 121 19.17 4.26 0.0 12.500 23.966 to 120.0 0.0 0.0 0.0 122 38.21 0.0005 0.0 12.500 0.006 Vel = 0.86 122 54.08 4.26 0.0 12.500 23.972 to 120.0 0.0 0.0 0.0 123 92.29 0.0024 0.0 12.500 0.030 Vel = 2.08 123 65.81 4.26 0.0 11.833 24.002 to 120.0 0.0 0.0 0.0 124 158.1 0.0064 0.0 11.833 0.076 Vel = 3.56 124 17.72 4.26 1 26.334 11.250 24.078 to 120.0 0.0 26.334 0.0 SPL 175.82 0.0079 0.0 37.584 0.297 Vel = 3.96 SPL -289.58 4.26 0.0 4.917 24.375 to 120.0 0.0 0.0 0.0 125 -113.76 -0.0035 0.0 4.917 -0.017 Vel = 2.56 125 19.89 4.26 0.0 6.333 24.358 to 120.0 0.0 0.0 0.0 126 -93.87 -0.0025 0.0 6.333 -0.016 Vel = 2.11 126 17.98 4.26 0.0 11.250 24.342 to 120.0 0.0 0.0 0.0 127 -75.89 -0.0017 0.0 11.250 -0.019 Vel = 1.71 127 16.45 4.26 0.0 10.667 24.323 to 120.0 0.0 0.0 0.0 128 -59.44 -0.0010 0.0 10.667 -0.011 Vel = 1.34 128 15.45 4.26 0.0 10.500 24.312 to 120.0 0.0 0.0 0.0 129 -43.99 -0.0006 0.0 10.500 -0.006 Vel = 0.99 129 14.88 4.26 0.0 10.500 24.306 to 120.0 0.0 0.0 0.0 130 -29.11 -0.0004 0.0 10.500 -0.004 Vel = 0.66 130 14.59 4.26 0.0 10.500 24.302 to 120.0 0.0 0.0 11.188 131 -14.52 0.0 0.0 10.500 0.0 Vel = 0.33 0.0 -14.52 35.490 K Factor = -2.44 SPL 289.58 6.357 21 25.147 16.875 24.375 to 120.0 0.0 25.147 0.0 TOR 289.58 0.0028 0.0 42.022 0.119 Vel= 2.93 TOR 0.0 6.357 0.0 26.000 24.494 to 120.0 0.0 0.0 11.261 BOR 289.58 0.0028 0.0 26.000 0.073 Vel = 2.93 0.0 289.58 35.828 K Factor = 48.38 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fi'nal Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 16 Berg Electric TI - Area 1 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 POP .000~i Fire Protection by Computer Design PACIFIC FIRE SYSTEMS, INC. 12316 OAK KNOLL RD. SUITE A POWAY, CA 92064 858-883-2333 Job Name : Berg Electric TI - Area 3 Drawing Location : 3182 LIONSHEAD AVE, CARLSBAD, CA Remote Area 1 Contract Data File Area 3.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PACIFIC FIRE SYSTEMS, INC. Page Berg Electric TI - Area 3 Date Hydraulic Design Information Sheet Name - BERGELECTRIC T.I. Date - 03-13-19 Location - 3182 LIONSHEAD AVE, CARLSBAD, CA Building - System No. - 1 Contractor - PACIFIC FIRE SYSTEMS, INC. Contract No. - Calculated By - C. LYONS Drawing No. - FP2 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - Occupancy - B AND S2 (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. (X) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. NFPA 231 ( ) NFPA 231C Figure Curve Other Specific Ruling Made By Date Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .10 (X) Wet Make VIKING Area Per Sprinkler - VARIES ( ) Dry Model VK602 Elevation at Highest Outlet - ll'-lo" ( ) Deluge Size 3/4" Hose Allowance - Inside - 100 ( ) Preaction K-Factor 8.0 Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 Hose Allowance - Outside - Note Based on existing calculation card residual GPM / PSI, manually peaked Calculation Flow Required - 288.787 Press Required - 35.974 Summary C-Factor Used: 120 Overhead Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Cap. - T Time of Test - Rated Cap.- Elev.- S Static Press - 8 Press - R Residual Press - Elev. - Well Flow - Proof Flow S Elevation - U P Location - P L Source of Information - Y C Commodity Class Location O Storage Ht. Area Aisle W. N Storage Method: Solid Piled % Palletized % Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G S Horizontal Barriers Provided: S Y S T E M D S S I G N Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C PACIFIC FIRE SYSTEMS, INC. Page 2 Berg Electric TI - Area 3 Date Demand: Dl - Elevation : 4.908 D2 - System Flow : 288.787 D2 - System Pressure : 35.974 Hose ( Demand) D3 - System Demand : 288.787 Safety Margin 150 140 130 p120 R° E10° S90 580 u 70 R6° E5° 40 - 2 30 - 20 - -- 'U I.I.I.I.... .. ..p.... ... I.... 50 100 150 200 250 300 350 400 450 FLOW (N ' 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram PACIFIC FIRE SYSTEMS, INC. Berg Electric TI - Area 3 0 SO - 6 63.3 0.1. ST -. 7 I 63.3 26. S8 -. 8 I 36.5 34. S9 - 9 0 512i,- 12 I 80 04. S13+- 13 80 26. $ S14-. 14 I 54 33.. S15#- 15 20.3 33 4. S18,-. 16 14.3 1001:4 100 14.3 14.4 101T- 101 28.8 63. 102w.-. 102 I 34.5 80 1031-. 103 114.5 13.1 1041:4 104 1 100.8 17. 105T-* 105 I 83.2 15. 1061:+ 106 t 67.2 14. 107i- 107 I 52.7 13-T 1081:+ 108 1 I 39 13.1 1091:+ 109 -1 I 25.8 12. 1101:9 110 1 I 12.9 Page 3 Date Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram PACIFIC FIRE SYSTEMS, INC. Berg Electric TI - Area 3 12. 111T-3. Ill 14.3 1201-. 120 1 14.3 121 T(--121 t 28.8 66. 122T- 122 I 95.4 78. 1231-. 123 1 I 174.3 13.t 1247- 124 17.6 125w- 125 83.2 126k-. 126 67.2 14. 127w- 127 52.7 128w- 128 39 13.. 129k- 129 25.8 12. i30- 130 - 12.9 12. i311-. 131 14.3 i00- i20T 14.4 i0- i2iT 63.3 63.3 102T-+6 -+7 -+8 -+9 122T 63.3 36.5 80 80 20.3 103T-+ 12 -+ 13 -+ 14 -+ 15 -+ 16 123T 80 54 13.7 l04- 124T 17.6 l051- 125T 15.9 lOST- 126T 14.6 107T- 127T Page 4 Date Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram PACIFIC FIRE SYSTEMS, INC. Page 5 Berg Electric TI - Area 3 Date 13.7 108- 128T 13.2 109-. 129T 12.9 110.- 130T 12.9 111- 131T 14.3 34.5 100.8 67.2 39 12.9 100-f 101-* 102.- 103,-. 1044-. 1054-. 1064-. 1074- 1084- 1094- 1104- 111 28.8 114.5 83.2 52.7 25.8 14.3 95.4 188 83.2 52.7 25.8 120.- 121.- 122.- 123€- 124+- SPL-4 125-. 126-. 127-. 128-. 129-. 130-4 131 28.8 174.3 100.8 67.2 39 12.9 288.8 SPLE- TOP..- BOR 288.8 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary PACIFIC FIRE SYSTEMS, INC. Page 6 Berg Electric TI - Area 3 Date Fitting Legend Abbrev. Name % % 1 1% 1% 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 I 90' Grvd-Vic Elbow #10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 T NFPA 139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD PACIFIC FIRE SYSTEMS, INC. Page 7 Berg Electric TI - Area 3 Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. S6 11.833 28.78 na S7 11.833 28.38 na SB 9.333 5.6 22.87 na 26.78 0.1 225 7.0 S9 11.833 8 18.42 na 34.33 1.0 1 17.0 S1O 11.833 8 18.42 na 34.33 1.0 1 17.0 S11 11.833 8 18.52 na 34.42 1.0 1 17.0 S12 11.833 28.12 na S13 11.833 -27.51 na S14 9.333 5.6 21.65 na 26.06 0.1 225 7.0 S15 11.833 8 17.74 na 33.69 1.0 1 10.6 S16 11.833 8 17.0 na 32.98 1.0 1 17.0 S17 11.833 8 17.02 na 33.0 1.0 1 17.0 S18 11.833 8 17.2 na 33.18 1.0 1 17.0 lOOT 28.0 23.06 na 101T 28.0 23.06 na 102T 28.0 22.56 na 103T 28.0 22.33 na 104T 28.0 23.21 na 105T 28.0 23.35 na 106T 28.0 23.42 na 107T 28.0 23.47 na 108T 28.0 23.5 na 109T 28.0 23.52 na hOT 28.0 23.53 na lilT 28.0 23.53 na 120T 28.0 23.38 na 121T 28.0 23.38 na 122T 28.0 22.92 na 123T 28.0 22.76 na 124T 28.0 23.51 na 125T 28.0 23.82 na 126T 28.0 23.81 na 127T 28.0 23.8 na 128T 28.0 23.8 na 129T 28.0 23.79 na 130T 28.0 23.79 na 131T 28.0 23.79 na 6 28.0 21.78 na 7 28.0 21.38 na 8 28.0 20.96 na 9 28.0 20.79 na 10 28.0 20.78 na 11 28.0 20.93 na 12 28.0 21.12 na 13 28.0 20.51 na 14 28.0 19.86 na 15 28.0 19.79 na 16 28.0 19.74 na 17 28.0 19.77 na 18 28.0 20.05 na 100 26.5 23.68 na 101 26.5 23.68 na 102 26.5 23.66 na 103 26.5 23.68 na 104 26.5 23.84 na 105 26.5 23.95 na 106 26.5 24.04 na 107 26.5 24.09 na 108 26.5 24.12 na 109 26.5 24.14 na 110 26.5 24.15 na 120 26.5 24.06 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard I PACIFIC FIRE SYSTEMS, INC. Page 8 Berg Electric TI - Area 3 Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 121 26.5 24.06 na 122 26.5 24.06 na 123 26.5 24.09 na 124 26.5 24.19 na SPL 26.5 24.52 na 125 26.5 24.51 na 126 26.5 24.5 na 127 26.5 24.48 na 128 26.5 24.47 na 129 26.5 24.47 na 130 26.5 24.46 na TOR 26.5 24.64 na BOR 0.5 35.97 na The maximum velocity is 12.78 and it occurs in the pipe between nodes S1 and 11 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams 0 PACIFIC FIRE SYSTEMS, INC. Page 9 Berg Electric TI - Area 3 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn S6 0.0 1.049 E 2.0 20.333 28.777 to 120.0 T 5.0 7.000 -7.002 6 0.0 0.0 0.0 27.333 0.0 Vel = 0 0.0 0.0 21.775 K Factor 0 S7 0.0 1.049 E 2.0 20.333 28.385 to 120.0 1 5.0 7.000 -7.002 7 0.0 0.0 0.0 27.333 0.0 Vel = 0 0.0 0.0 21.383 K Factor =0 S8 26.78 1.049 E 2.0 20.667 22.868 K Factor = 5.60 to 120.0 T 5.0 7.000 -8.085 8 26.78 0.2233 0.0 27.667 6.179 Vel = 9.94 0.0 26.78 20.962 K Factor = 5.85 S9 34.33 1.049 E 2.0 19.500 18.417 K Factor = 8.00 to 120.0 T 5.0 7.000 -7.002 9 34.33 0.3536 0.0 26.500 9.371 Vel = 12.74 0.0 34.33 20.786 K Factor= 7.53 S10 34.33 1.049 E 2.0 19.500 18.416 K Factor =8.00 to 120.0 T 5.0 7.000 -7.002 10 34.33 0.3536 0.0 26.500 9.371 Vel = 12.74 0.0 34.33 20.785 K Factor= 7.53 Sil 34.42 1.049 E 2.0 19.500 18.516 K Factor= 8.00 to 120.0 T 5.0 7.000 -7.002 11 34.42 0.3554 0.0 26.500 9.418 VeI= 12.78 0.0 34.42 20.932 K Factor 7.52 S12 0.0 1.049 E 2.0 19.167 28.120 to 120.0 1 5.0 7.000 -7.002 12 0.0 0.0 0.0 26.167 0.0 Vel = 0 0.0 0.0 21.118 K Factor =0 S13 0.0 1.049 E 2.0 19.167 27.513 to 120.0 T 5.0 7.000 -7.002 13 0.0 0.0 0.0 26.167 0.0 Vel = 0 0.0 0.0 20.511 K Factor =0 S14 26.06 1.049 E 2.0 22.667 21.648 K Factor= 5.60 to 120.0 T 5.0 7.000 -8.085 14 26.06 0.2123 0.0 29.667 6.297 Vel = 9.67 0.0 26.06 19.860 K Factor = 5.85 S15 33.69 1.049 E 2.0 19.500 17.738 K Factor = 8.00 to 120.0 T 5.0 7.000 -7.002 15 33.69 0.3415 0.0 26.500 9.051 Vel = 12.51 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 10 Berg Electric TI - Area 3 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 33.69 19.787 K Factor= 7.57 S16 32.98 1.049 E 2.0 22.667 17.000 K Factor= 8.00 to 120.0 1 5.0 7.000 -7.002 16 32.98 0.3284 0.0 29.667 9.742 Vel = 12.24 0.0 32.98 19.740 K Factor= 7.42 S17 33.00 1.049 E 2.0 22.667 17.020 K Factor = 8.00 to 120.0 T 5.0 7.000 -7.002 17 33.0 0.3287 0.0 29.667 9.752 Vel = 12.25 0.0 33.00 19.770 K Factor = 7.42 S18 33.18 1.049 E 2.0 22.667 17.204 K Factor = 8.00 to 120.0 T 5.0 7.000 -7.002 18 33.18 0.3320 0.0 29.667 9.850 Vel = 12.32 0.0 33.18 20.052 K Factor = 7.41 lOOT -14.33 2.157 T 12.307 1.500 23.059 to 120.0 0.0 12.307 0.650 100 -14.33 -0.0021 0.0 13.807 -0.029 VeI= 1.26 0.0 -14.33 23.680 K Factor= -2.94 101T -14.42 2.157 T 12.307 1.500 23.056 to 120.0 0.0 12.307 0.650 101 -14.42 -0.0021 0.0 13.807 -0.029 Vel = 1.27 0.0 -14.42 23.677 K Factor= -2.96 102T 63.25 2.157 1 12.307 1.500 22.562 to 120.0 0.0 12.307 0.650 102 63.25 0.0327 0.0 13.807 0.452 Vel = 5.55 0.0 63.25 23.664 KFactor= 13.00 103T 80.02 2.157 T 12.307 1.500 22.334 to 120.0 0.0 12.307 0.650 103 80.02 0.0506 0.0 13.807 0.698 Vel = 7.03 0.0 80.02 23.682 K Factor= 16.44 104T -13.73 2.157 T 12.307 1.500 23.214 to 120.0 0.0 12.307 0.650 104 -13.73 -0.0020 0.0 13.807 -0.027 Vel = 1.21 0.0 -13.73 23.837 K Factor= -2.81 105T -17.62 2.157 T 12.307 1.500 23.346 to 120.0 0.0 12.307 0.650 105 -17.62 -0.0030 0.0 13.807 -0.042 Vel = 1.55 0.0 -17.62 23.954 K Factor -3.60 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 11 Berg Electric TI - Area 3 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1061 -15.93 2.157 T 12.307 1.500 23.421 to 120.0 0.0 12.307 0.650 106 -15.93 -0.0026 0.0 13.807 -0.036 Vel = 1.40 0.0 -15.93 24.035 K Factor= -3.25 107T -14.57 2.157 T 12.307 1.500 23.471 to 120.0 0.0 12.307 0.650 107 -14.57 -0.0022 0.0 13.807 -0.031 VeI= 1.28 0.0 -14.57 24.090 K Factor= -2.97 108T -13.69 2.157 T 12.307 1.500 23.501 to 120.0 0.0 12.307 0.650 108 -13.69 -0.0020 0.0 13.807 -0.027 Vel = 1.20 0.0 -13.69 24.124 K Factor= -2.79 109T -13.18 2.157 T 12.307 1.500 23.518 to 120.0 0.0 12.307 0.650 109 -13.18 -0.0019 0.0 13.807 -0.026 VeI= 1.16 0.0 -13.18 24.142 K Factor= -2.68 hOT -12.93 2.157 T 12.307 1.500 23.526 to 120.0 0.0 12.307 0.650 110 -12.93 -0.0018 0.0 13.807 -0.025 Vel = 1.14 0.0 -12.93 24.151 KFactor= -2.63 lilT -12.86 2.157 T 12.307 1.500 23.528 to 120.0 0.0 12.307 11.838 111 -12.86 -0.0017 0.0 13.807 -0.024 Vel = 1.13 0.0 -12.86 35.342 KFactor= -2.16 120T 14.33 2.157 T 12.307 1.500 23.380 to 120.0 0.0 12.307 0.650 120 14.33 0.0020 0.0 13.807 0.028 Vel = 1.26 0.0 14.33 24.058 K Factor= 2.92 121T 14.42 2.157 T 12.307 1.500 23.380 to 120.0 0.0 12.307 0.650 121 14.42 0.0021 0.0 13.807 0.029 Vel = 1.27 0.0 14.42 24.059 K Factor= 2.94 122T 66.62 2.157 T 12.307 1.500 22.916 to 120.0 0.0 12.307 0.650 122 66.62 0.0360 0.0 13.807 0.497 Vel = 5.85 0.0 66.62 24.063 K Factor= 13.58 123T 78.90 2.157 T 12.307 1.500 22.765 to 120.0 0.0 12.307 0.650 123 78.9 0.0493 0.0 13.807 0.680 Vel 6.93 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams p PACIFIC FIRE SYSTEMS, INC. Page 12 Berg Electric TI - Area 3 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 78.90 24.095 K Factor= 16.07 1241 13.73 2.157 T 12.307 1.500 23.510 to 120.0 0.0 12.307 0.650 124 13.73 0.0019 0.0 13.807 0.026 Vel = 1.21 0.0 13.73 24.186 K Factor = 2.79 1251 17.62 2.157 T 12.307 1.500 23.816 to 120.0 0.0 12.307 0.650 125 17.62 0.0030 0.0 13.807 0.042 Vel = 1.55 0.0 17.62 24.508 K Factor = 3.56 126T 15.93 2.157 T 12.307 1.500 23.811 to 120.0 0.0 12.307 0.650 126 15.93 0.0025 0.0 13.807 0.035 Vel = 1.40 0.0 15.93 24.496 K Factor = 3.22 127T 14.57 2.157 T 12.307 1.500 23.801 to 120.0 0.0 12.307 0.650 127 14.57 0.0021 0.0 13.807 0.029 Vel = 1.28 0.0 14.57 24.480 K Factor = 2.94 128T 13.69 2.157 1 12.307 1.500 23.795 to 120.0 0.0 12.307 0.650 128 13.69 0.0019 0.0 13.807 0.026 Vel = 1.20 0.0 13.69 24.471 KFactor= 2.77 129T 13.18 2.157 1 12.307 1.500 23.792 to 120.0 0.0 12.307 0.650 129 13.18 0.0017 0.0 13.807 0.024 VeI= 1.16 0.0 13.18 24.466 K Factor = 2.66 130T 12.93 2.157 1 12.307 1.500 23.790 to 120.0 0.0 12.307 0.650 130 12.93 0.0017 0.0 13.807 0.024 VeI= 1.14 0.0 12.93 24.464 K Factor = 2.61 1311 12.86 2.157 T 12.307 1.500 23.790 to 120.0 0.0 12.307 11.838 131 12.86 0.0017 0.0 13.807 0.024 Vel = 1.13 0.0 12.86 35.652 K Factor = 2.15 lOOT 14.33 2.157 2T 24.613 128.000 23.059 to 120.0 0.0 24.613 0.0 120T 14.33 0.0021 0.0 152.613 0.321 Vel= 1.26 0.0 14.33 23.380 K Factor = 2.96 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 13 Berg Electric TI - Area 3 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 101T 14.42 2.157 21 24.613 128.000 23.056 to 120.0 0.0 24.613 0.0 121T 14.42 0.0021 0.0 152.613 0.324 Vel = 1.27 0.0 14.42 23.380 K Factor = 2.98 1021 -63.25 2.157 T 12.307 11.750 22.562 to 120.0 0.0 12.307 0.0 6 -63.25 -0.0327 0.0 24.057 -0.787 Vet = 5.55 6 0.0 2.157 0.0 12.000 21.775 to 120.0 0.0 0.0 0.0 7 -63.25 -0.0327 0.0 12.000 -0.392 Vet = 5.55 7 0.0 2.157 0.0 12.875 21.383 to 120.0 0.0 0.0 0.0 8 -63.25 -0.0327 0.0 12.875 -0.421 Vel = 5.55 8 26.78 2.157 0.0 14.875 20.962 to 120.0 0.0 0.0 0.0 9 -36.47 -0.0118 0.0 14.875 -0.176 Vel = 3.20 9 34.33 2.157 0.0 18.000 20.786 to 120.0 0.0 0.0 0.0 10 -2.14 -0.0001 0.0 18.000 -0.001 Vet= 0.19 10 34.33 2.157 0.0 15.708 20.785 to 120.0 0.0 0.0 0.0 11 32.19 0.0094 0.0 15.708 0.147 VeI= 2.83 11 34.43 2.157 T 12.307 42.792 20.932 to 120.0 0.0 12.307 0.0 122T 66.62 0.0360 0.0 55.099 1.984 Vet = 5.85 0.0 66.62 22.916 KFactor= 13.92 103T -80.02 2.157 1 12.307 11.750 22.334 to 120.0 0.0 12.307 0.0 12 -80.02 -0.0505 0.0 24.057 -1.216 Vel = 7.03 12 0.0 2.157 0.0 12.000 21.118 to 120.0 0.0 0.0 0.0 13 -80.02 -0.0506 0.0 12.000 -0.607 Vel = 7.03 13 0.0 2.157 0.0 12.875 20.511 to 120.0 0.0 0.0 0.0 14 -80.02 -0.0506 0.0 12.875 -0.651 Vel = 7.03 14 26.05 2.157 0.0 3.000 19.860 to 120.0 0.0 0.0 0.0 15 -53.97 -0.0243 0.0 3.000 -0.073 Vel = 4.74 15 33.69 2.157 0.0 11.875 19.787 to 120.0 0.0 0.0 0.0 16 -20.28 -0.0040 0.0 11.875 -0.047 Vel = 1.78 16 32.99 2.157 0.0 18.000 19.740 to 120.0 0.0 0.0 0.0 17 12.71 0.0017 0.0 18.000 0.030 Vel = 1.12 17 33.00 2.157 0.0 15.708 19.770 to 120.0 0.0 0.0 0.0 18 45.71 0.0180 0.0 15.708 0.282 Vel = 4.01 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 14 Berg Electric TI - Area 3 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 18 33.19 2.157 T 12.307 42.792 20.052 to 120.0 0.0 12.307 0.0 123T 78.9 0.0492 0.0 55.099 2.713 Vel = 6.93 0.0 78.90 22.765 KFactor= 16.54 104T 13.73 2.157 2T 24.613 128.000 23.214 to 120.0 0.0 24.613 0.0 1241 13.73 0.0019 0.0 152.613 0.296 Vel = 1.21 0.0 13.73 23.510 KFactor= 283 1051 17.62 2.157 2T 24.613 128.000 23.346 to 120.0 0.0 24.613 0.0 125T 17.62 0.0031 0.0 152.613 0.470 Vel = 1.55 0.0 17.62 23.816 K Factor = 3.61 106T 15.93 2.157 2T 24.613 128.000 23.421 to 120.0 0.0 24.613 0.0 1261 15.93 0.0026 0.0 152.613 0.390 Vel = 1.40 0.0 15.93 23.811 K Factor = 3.26 1071 14.57 2.157 21 24.613 128.000 23.471 to 120.0 0.0 24.613 0.0 1271 14.57 0.0022 0.0 152.613 0.330 Vel = 1.28 0.0 14.57 23.801 K Factor = 2.99 1081 13.69 2.157 21 24.613 128.000 23.501 to 120.0 0.0 24.613 0.0 1281 13.69 0.0019 0.0 152.613 0.294 Vel = 1.20 0.0 13.69 23.795 K Factor = 2.81 1091 13.18 2.157 21 24.613 128.000 23.518 to 120.0 0.0 24.613 0.0 1291 13.18 0.0018 0.0 152.613 0.274 Vel= 1.16 0.0 13.18 23.792 K Factor = 2.70 11 OT 12.93 2.157 21 24.613 128.000 23.526 to 120.0 0.0 24.613 0.0 1301 12.93 0.0017 0.0 152.613 0.264 Vel= 1.14 0.0 12.93 23.790 K Factor = 2.65 1111 12.86 2.157 21 24.613 128.000 23.528 to 120.0 0.0 24.613 0.0 1311 12.86 0.0017 0.0 152.613 0.262 VeI 1.13 0.0 12.86 23.790 K Factor = 2.64 100 -14.33 3.26 0.0 12.500 23.680 to 120.0 0.0 0.0 0.0 101 -14.33 -0.0002 0.0 12.500 -0.003 Vel = 0.55 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 iial Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 15 Berg Electric TI - Area 3 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "Ct' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 101 -14.43 3.26 0.0 12.500 23.677 to 120.0 0.0 0.0 0.0 102 -28.76 -0.0010 0.0 12.500 -0.013 VeI= 1.11 102 63.25 3.26 0.0 12.500 23.664 to 120.0 0.0 0.0 0.0 103 34.49 0.0014 0.0 12.500 0.018 Vel = 1.33 103 80.03 3.26 0.0 11.833 23.682 to 120.0 0.0 0.0 0.0 104 114.52 0.0131 0.0 11.833 0.155 Vel= 4.40 104 -13.73 3.26 0.0 11.250 23.837 to 120.0 0.0 0.0 0.0 105 100.79 0.0104 0.0 11.250 0.117 Vel = 3.87 105 -17.62 3.26 0.0 11.250 23.954 to 120.0 0.0 0.0 0.0 106 83.17 0.0072 0.0 11.250 0.081 Vel = 3.20 106 -15.94 3.26 0.0 11.250 24.035 to 120.0 0.0 0.0 0.0 107 67.23 0.0049 0.0 11.250 0.055 Vel = 2.58 107 -14.57 3.26 0.0 10.667 24.090 to 120.0 0.0 0.0 0.0 108 52.66 0.0032 0.0 10.667 0.034 Vel = 2.02 108 -13.69 3.26 0.0 10.500 24.124 to 120.0 0.0 0.0 0.0 109 38.97 0.0017 0.0 10.500 0.018 Vel = 1.50 109 -13.18 3.26 0.0 10.500 24.142 to 120.0 0.0 0.0 0.0 110 25.79 0.0009 0.0 10.500 0.009 Vel = 0.99 110 -12.93 3.26 0.0 10.500 24.151 to 120.0 0.0 0.0 11.188 111 12.86 0.0003 0.0 10.500 0.003 VeI= 0.49 0.0 12.86 35.342 K Factor = 2.16 120 14.33 4.26 0.0 12.500 24.058 to 120.0 0.0 0.0 0.0 121 14.33 0.0001 0.0 12.500 0.001 Vel = 0.32 121 14.43 4.26 0.0 12.500 24.059 to 120.0 0.0 0.0 0.0 122 28.76 0.0003 0.0 12.500 0.004 Vel = 0.65 122 66.61 4.26 0.0 12.500 24.063 to 120.0 0.0 0.0 0.0 123 95.37 0.0026 0.0 12.500 0.032 Vel = 2.15 123 78.90 4.26 0.0 11.833 24.095 to 120.0 0.0 0.0 0.0 124 174.27 0.0077 0.0 11.833 0.091 Vel = 3.92 124 13.73 4.26 T 26.334 11.250 24.186 to 120.0 0.0 26.334 0.0 SPL 188.0 0.0089 0.0 37.584 0.336 Vel = 4.23 SPL -288.79 4.26 0.0 4.917 24.522 to 120.0 0.0 0.0 0.0 125 -100.79 -0.0028 0.0 4.917 -0.014 Vel = 2.27 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 iIal Calculations - Hazen-Williams PACIFIC FIRE SYSTEMS, INC. Page 16 Berg Electric TI - Area 3 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 125 17.62 4.26 0.0 6.333 24.508 to 120.0 0.0 0.0 0.0 126 -83.17 -0.0019 0.0 6.333 -0.012 Vel = 1.87 126 15.94 4.26 0.0 11.250 24.496 to 120.0 0.0 0.0 0.0 127 -67.23 -0.0014 0.0 11.250 -0.016 Vel = 1.51 127 14.57 4.26 0.0 10.667 24.480 to 120.0 0.0 0.0 0.0 128 -52.66 -0.0008 0.0 10.667 -0.009 Vel = 1.19 128 13.69 4.26 0.0 10.500 24.471 to 120.0 0.0 0.0 0.0 129 -38.97 -0.0005 0.0 10.500 -0.005 Vel = 0.88 129 13.18 4.26 0.0 10.500 24.466 to 120.0 0.0 0.0 0.0 130 -25.79 -0.0002 0.0 10.500 -0.002 Vel = 0.58 130 12.93 4.26 0.0 10.500 24.464 to 120.0 0.0 0.0 11.188 131 -12.86 0.0 0.0 10.500 0.0 Vel = 0.29 0.0 -12.86 35.652 K Factor= -2.15 SPL 288.79 6.357 21 25.147 16.875 24.522 to 120.0 0.0 25.147 0.0 TOR 288.79 0.0028 0.0 42.022 0.118 VeI= 2.92 TOR 0.0 6.357 0.0 26.000 24.640 to 120.0 0.0 0.0 11.261 BOR 288.79 0.0028 0.0 26.000 0.073 Vel = 2.92 0.0 288.79 35.974 K Factor= 48.15 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MATERIAL CUT SHEET BERGELECTRIC T.I. 3182 LIONSHEAD AVE CARLSBAD, CA Worldwide I tqcu Contacts wWW.tyco-fire.com Series TYB - 2.8.q 5.6,, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described in herein are standard response, standard coverage, decora- tive 5 mm glass bulb-type spray sprin- klers. They are designed for use in light, ordinary, or extra-hazard commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The TY-B Recessed Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 in. (12,7 mm) of recessed adjust- ment or up to 3/4 in. (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond what would be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 it is recommended that the end-user be consulted about the suitability of these coatings for any given corrosive envi- ronment. The effects of ambient tem- perature, concentration of chemicals, and gas/chemical velocity, should be considered as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-B Pendent Sprinkler can be obtained by utilizing the Series TY-B Pendent Sprinkler in combination with the Model S2 Shield. NOTICE The Series TY-B 2.8, 5.6, and 8.0 K-fac- tor, Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (NFPA), in addition to the standards of any other authorities ha ving jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condi- tion. Contract the installing contrac- tor or product manufacturer with any questions. NFPA 13 prohibits installation of 1/2 in. NPT sprinklers with K-factors greater than 5.6 in new construction. They are intended for retrofit in existing sprinkler systems only. Sprinkler Identification Numbers (SIN) TY1151 ... Upright 2.8K, 1/2 in. NPT TY1251 . . .Pendent 2.8K, 1/2 in. NPT TY3151 ... Upright 5.6K, 1/2 in. NPT TY3251... Pendent 5.6K, 1/2 in. NPT TY4151 ... Upright 8.0K, 3/4 in. NPT TY4251 . . .Pendent 8.0K, 3/4 in. NPT TY4851 ... Upright 8.01K, 1/2 in. NPT TY4951 . . . Pendent 8.0K, 1/2 in. NPT JULY 2018 / \ - 'ut III 111 17 - Technical Data Approvals UL and C-UL Listed FM, LPCB, VdS, and NYC Approved Refer to Table A for complete approval infor- mation, including corrosion-resistant status. Maximum Working Pressure Refer to Table B Discharge Coefficient K=2.8 GPM/psi/2 (40,3 LPM/bar") K=5.6 GPM/psi/2 (80,6 LPM/bar") K=8.0 GPM/psi'/' (115,2 LPM/bar½) Temperature Ratings Refer to Table A Finishes Sprinkler: Refer to Table C Recessed Escutcheon: Signal or Pure White, Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Bulb ................ ............... Glass Compression Screw .................Bronze Deflector .........................Copper Bushing (K=2.8) ....................Bronze TFPI5I 7/16 1,1 mm) OMINAL RAKE-IN 2-3/16 (55,6 mm) UPRIGHT PENDENT 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) STYLE 11 RECESSEu ESCUTCHEON RECESSED PENDENT CROSS SECTION TFPI5I Page 2 of 8 7/16" (11,1 mm) NOMINAL \ / MAKE-IN 23/16 mm) I F/~'ff I I 1/2 NPT** WRENCH FLATS UPRIGHT PENDENT CEILING PLATE 1 - Frame 5 - Compression 2 - Button Screw SEATING SURFACE _ 3 - Sealing 6 - Deflector* 7 Assembly 7 - Bushing /// 1 4-Bulb _______ 2-1/4 - (57,2 mm) * Temperature rating is indicated on Deflector. 1-9/16 (39,7 mm) I - 5 ** Pipe thread connections per ISO 7-1 can be 6* provided on special request. CROSS SECTION FIGURE 1 SERIES TV-B UPRIGHT (TYI151) AND PENDENT (TV1251) SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE * Temperature rating ** Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector. special request. PLATE SEATING SURFACE 3 - Sealing, 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* 7/16 :11'1 mm) i \IOMINAL 2-3/16 MAKE-IN (55,6 mm) 2-3/16 1-1/2 I (38,1 mm) (556mm) 1 1 1/2 NPT** I WRENCH STYLE 10 -.---- 2-7/8" (73,0 mm) DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2 ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. POLY-STAINLESS FINISH ONLY FIGURE 2 SERIES TV-B UPRIGHT (TY3151) AND PENDENT (TV3251) SPRINKLERS 5.6 K-FACTOR, 112 IN. NPT, STANDARD RESPONSE CROSS SECTION TFPI5I Page 3 of 8 * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* ESCUTCHEON PLATE SEATING SURFACE N 1/2' (12,7 mm) 2-5/16' NOMINAL MAKE-IN j (58,7 mm) 2-1/4" (39,7 mm) (57,2mm) 3/4' NPT** I WRENCH STYLE 40 ..- 2-7/8" (73,0 mm) DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. 1/2" (12,7 mm) I NOMINAL I _______ 2-5/16" MAKE-IN (58,7 mm) 16" (39 (57,2 mm) - STYLE 40 2-7/8" (73,0 mm) DIA.J RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT POLY-STAINLESS FINISH ONLY FIGURE 3 SERIES TY-B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS 8.0 K-FACTOR, 3/4 IN. NPT, STANDARD RESPONSE 7/16" (11,1 mm) NOMINAL MAKE-IN 23/16 (55,6 mm) 1/2" NPT** t WRENCH FLATS UPRIGHT PENDENT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 13 - Sealing 6 - Deflector* Assembly 4 - Bulb 2-1/4" ~~q (57,2 mm) *Temperature rating is 1-9/16" 4 indicated on Deflector. (39,7 mm) ** Pipe thread connections per ISO 7-1 can be 6* provided on special request. CROSS SECTION FIGURE 4 SERIES TV-B UPRIGHT (TV4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K-FACTOR, 112 IN. NPT, STANDARD RESPONSE TFPI5I Page 4 of 8 2-7/8 DIA. 5/8±1/4' (73,0 mm) I 3/4" (19,1 mm) (159±6,4 mm) 2-1/4' CIA. 1/4' (6,4 mm) SPRINKLER PLATE FACE OF (57,2 mm)MOUTING FITTING 1/8" L (3,2 mm) MOUNTING SURFACE 1 SERIES 1-1/4" (31,8 mm) CLOSURE TYB 3/4" (19,1 mm) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 7 W-TYPE 6 SPRINKLER WRENCH - 2-7/8" DIA. 5/8±1/4" (73,0 mm) -H 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) I I FACE OF (57,2 mm) -H I I MOUNTING I I SPRINKLER PLATE FITTING (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm)I TYB 13/16" (20,6 mm) FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH Poly-Stainless Physical Characteristics Frame ............................Bronze Button ................L316 Stainless Steel' Bulb ...............................Glass Compression Screw .....L316 Stainless Steel* Deflector ...................Copper/Bronze Sealing Assembly. Gold Plated Beryllium Nickel w/T EFLO N 'Type L316 stainless steel (UNS 31603) per ASTM A479/479M or OS EN 1006 WN1.4404, Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency, such as UL Listing based on the requirements of NFPA 13 and FM Approval based on the requirements of the FM Global Loss Prevention Data Sheets. Use only the Style 10 or 40 Recessed Escutcheon, as applicable, for recessed pendent installations. Installation The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) to 3/32 in. (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by apply- ing a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). Obtain a leak-tight 3/4 in. NPT sprinkler joint by applying a minimum to maximum TFPI5I Page 5 of 8 K Sprinkler Type Temperature Rating Bulb Liquid Color Sprinkler Finish8 Natural Brass I Chrome Plated olyesterc PolyStainlc ess Lead Coated I Wax Coated I Wax-Over- I Lead Coated 135°F (57°C) Orange 2.8 1/2 ". NPT Upright (TYII51) and Pendent (TY1251) 1, 2, 3 N/A N/Ad 155°F (68°C) I Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Figure 1 360'F (182'C) Mauve 1,2 135°F (57°C) Orange Upright (TY3151) and Pendent (TY3251) 1, 2, 3, 4, 5, 6, 7 1,2 1,2,3,5 1,2,3,5 1,2,3,5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue ib, 2b, 3b, 5b ib, 2b, 3b, 5b 5.6 Figure 2 360-F (182-C) Mauve N/A 1/2 in. NPT 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY3251)a 1, 2, 3, 4, 5 1,2 N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 5 286°F (141°C) Blue 1,2 135°F (57°C) Orange Upright (TY4151) and Pendent (1Y4251) 1, 2, 3, 4, 5, 6, 7 1,2 1,2,5 1,2,3,5 1,2,5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue ib, 2b, 3b, 5b lb. 2b, 5b 80 Figure 3 360°F (182°C) Mauve N/A 3/4 in. NPT 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY4251)° 1,2,3,4,5 1,2 N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 6 286°F (141°C) Blue 1,2 135°F (57°C) Orange 8.0 1/21n. NPT Upright (TY4851) and Pendent (TY4951) 155°F (68°C) Red 1,2,3,4,5,6 N/A N/A 175°F(79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Figure 4 360°F(182°C) I Mauve NOTES Listed by Underwriters Laboratories, Inc. )UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by FM Global (FM Approvals). Approved by the Loss Prevention Certification Board )LPCB Ref. No. 007k/03). Approved by the City of New York under MEA 354-01-E. VdS Approved. (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-44441 Fax 31-53-428-3377) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05) Where Polyester Coated, Lead Coated, Wax Coated, and Was-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. Installed with Style 10(1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable 150°F (66°C) maximum ceiling temperature Frame and deflector only Not Applicable (N/A) TABLE A SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFPI5I Page 6 of 8 Sprinkler Finish K Type I I Natural Brass Chrome Polyester1 Lead I Wax Wax-Over-Lead Plated Coated Coated i Coated 2.8 Upright (TY1151) 1/2 in. and 175 psi (12,1 bar) N/As NPT Pendent (TY1251) Upright (TY3151) and 5.6 Pendent (TY3251) 250 psi (17,2 bar)2 1/2 in. or NPT 175 psi (12,1 bar) Recessed Pendent (TY3251) Upright (TY4151) and 175 psi (12,1 bar) 8.0 Pendent (TY4251) 3/4 in. NPT Recessed Pendent (TY4251) 175 psi (12,1 bar) I N/A 8.0 Upright (TY4851) 1/2 in. and 175 psi (12,1 bar) NPT Pendent (TY4951) NOTES Frame and deflector only The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL), the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL), and the Approval by the City of New York. Not Applicable (N/A) TABLE B SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE torque of 10 to 20 lb-ft (13,4 to 26,8 N.m). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the escutch- eon plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TV-B Upright and Pendent Sprinklers Installation The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. Install pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 7). For wax-coated sprinklers, use an 8 or 10 in. adjustable wrench. With reference to Figure 1 to 4, apply the W-Type 6 Recessed Sprinkler Wrench or an adjustable wrench, as applicable, to the sprinkler wrench flats. Wax Coated Sprinklers When installing wax-coated sprinklers with an adjustable wrench, take care to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environment: Open the jaws of the wrench suffi- ciently wide to pass over the wrench flats without damaging the wax coating. Before wrench tightening the sprin- kler, adjust the jaws of the wrench to contact only the sprinkler wrench flats. After wrench tightening the sprin- kler, loosen the wrench jaws before removing the wrench. After Installation After installation, complete the following: Inspect the sprinkler wrench flats and frame arms and retouch (repair) the wax coating whenever the coat- ing has been damaged and bare metal is exposed. Retouch the wax coating on the wrench flats by gently applying a heated 1/8 inch diameter steel rod to the damaged areas of wax, to smooth it back over areas where bare metal is exposed. NOTICE Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point it can begin to melt the wax, and appropriate precautions need to be taken when handling the heated rod in order to prevent the installer from being burned. TFPI5I Page 7 of 8 Series TV-B Recessed Pendent Sprinklers The Series TY-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 or 4, apply the W-Type 7 Recessed Sprin- kler wrench to the sprinkler wrench flats. Step 3. After the ceiling is installed or the finish coat is applied, slide on the Style 10 or 40 Closure over the Series TY-B Recessed Pendent Sprinkler and push the Closure over the Mount- ing Plate until its flange contacts the ceiling. Care and Maintenance The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Absence of an escutcheon, which is used to cover a clearance, may delay the time to sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. Refer to the Instal- lation Section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. 530 2.8K UPRIGHT (1/2 fl. NPT) I Y1151 531 2.3K PENDENT (1/2 in. NPT) TY1251 570 56K UPRIGHT (1/2 in. NPT) TY3151 571 5.6K PENDENT (1/2 in. NPT) TY3251 590 8.0K UPRIGHT (314 in. NPT) TY4151 591 8.0K PENDENT (3/4 in. NPT) TY4251 560 8.0K UPRIGHT (1/2 in. NPT) TY4851 561 8 OK PENDENT (1/2 in. NPT) TY4951 SIN SPRINKLER FINISH 1 NATURAL BRASS POLY-STAINLESS GREY 2 ALUMINUM (RAL9007)1 POLYESTER PURE WHITE (RAL9010)2 POLYESTER SIGNAL WHITE (RAL9003) POLYESTER JET BLACK (RAL9005)3 POLYESTER 6 WAX COATED - 286°F (141°C) MAX 7 LEAD COATED a WAX-OVER-LEAD - 286°F (141°C) MAX 9 CHROME PLATED TFPI5I Page 8 of 8 P/N 57 - XXX — X - XXX TEMPERATURE RATING 135 I 135°F (57°C) 155 155°F(68°C) 175 175°F(79°C) 200 200° F (93°C) 286 286°F (141°C) 360 1 360°F (182°C) 000 ( OPEN NOTES 1 Only available on 1Y3151, TY3251, TY4151, and TY4251. 2, Eastern Hemisphere sales only. 3. Available in only 8.0K, 155°F (68°C) or 200°F (93'C); requires lead time to manufacture. Available only for 8.0 K-factorTY4151 and 1Y4251 for use in deluge systems ('OPEN" indicates sprinkler assembly without glass bulb, button, and sealing assembly). TABLE C SERIES TV-B UPRIGHTAND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TV-B (specify SIN), (specify K-factor), (specify Upright or Pendent) Sprinkler with (specify) temperature rating, (specify) finish or coating, P/N (Refer to Table C) Recessed Escutcheon Specify: Style (10 or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) ° Refer to Technical Data Sheet TFP770 Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Wax Sticks (for retouching wrench- damaged wax coating) Specify: (specify color, below) Color- coded Wax Sticks for retouching (specify temperature rating) tempera- ture-rated Series TV-B Sprinklers, P/N (specify) Black for 135°F (57°C) ......P/N 56-065-1-135 Rod for 155°F (68°C) .......P/N 56-065-1-155 Yellow for 175°F (79°C) .....P/N 56-065-1-175 Blue for 200°F (93°C) and 286°F (141°C) .........P/N 56-065-1- 286 Note: Each wax stick is suitable for retouching up to 25 sprinklers. The wax used for286°F (141°C) sprinklers is the same as for2000F (93°C) sprinklers. Therefore, the 286°F (141°C) sprinkler is limited to the same maximum ceiling temperature as the 200°F (93°C) sprinkler which is 150°F (66°C). 1400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 il ? 02018 Johnson Controls. All rights r050rvod. All specifications and other Information shown were currant 05sf document revision data and are subject to change without notice. Johnson NATIONAL FIRE PROTECTION ASSOCIATION cod NFPAu,o tcSstorod tmdemud,s nt National Fire PwtetIun Ascociotlon; TEFLON Isa registered t,ademu,1, of Dupont Controls For Light Hazard Occupancies Only NOTE: As of May 2018 all logos have been removed from the wrench boss. WARNING; Cancer and Reproductive . Harm- wP65Warningsca.gov Specifications: Available since 2013. Minimum Operating Pressure: Refer to the Approval Charts. Maximum Working Pressure: 175 psi (12 Bar). Factory tested hydrostatically to 500 psi (34.5 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread sizes: 3/4" (20 mm) NPT Nominal K-Factors: 8.0 U.S. (115.2 metrict) t Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/8" (60 mm) Refer to Approval Chart I and Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. 1. DESCRIPTION Viking EC/QREC Pendent Sprinkler VK602 is a small thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements. This sprinkler has both standard response and quick response listings. The glass bulb operating element and special deflector char- acteristics meet the challenges of quick response extended coverage standards. The special Polyester coating can be used in decorative applications where colors are desired. 2.. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class 2020 Material Standards: Sprinkler Frame: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list) Order EC/QREC Pendent Sprinkler VK602 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, and Black Polyester M-/B Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D For example, sprinkler VK602 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 18262BAB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B (available since 2017) Wrench for recessed pendent sprinklers: Part No. 13577W/B*w (available since 2006) **A 1/' ratchet is required (not available from Viking). Form No. F_102412 18.10.18 Rev 18.2.P65 Replaces Form No. F_102412 Rev 18.2 (Added P65 Warning.) Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands,causing the glass to shatter, releasing the pip cap and sealing springassembly. Water flowing through the sprinkler orifice strikes the sprinklerdeflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking ECIQREC Pendent Sprinkler VK602 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Bulb Color Ceiling Temperature ii Ordinary 135 °F (57 °C) 100 °F (38 00) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 F (65 00) Yellow Sprinkler Finishes: Brass, Chrome, White Polyester 3, and Black Polyester3 Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester coatings. Wrench Flat I. Protective Sprinkler clip Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F102412 18.10.18 Rev 18.2.P65 Page 3 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this tecinical data page www.vikinggroupinc.com. Approval Chart I (UL) KE Standard/Quick Response Extended Coverage Pendent Sprinkler For Light Hazard Occupncies Onlj AIX 4 F Maximuii 175 PSI (12 Bar) WV/P Sprinkler NPT Nominal Maximum Areas Minimum Water Supply Requirements4 Listings and Approvals3 Base SIN Thread Size K-Factor of Coverage' (Refer also to Design U.S. metric2 (Length x Width) Part No.' Inches mm Criteria.) Standard Response Applications' cULus5 18262 VK602 3/4 20 8.0 115.2 20' x 20' (6.1 m 6.1 m) 40 gpm @ 25.0 psi (151.4 LJmin @ 1.72 Bar) A1Z Quick Response Appications 18262 VK602 3/4 20 8.0 115.2 16' x 16' (4.9 m 4.9 m) 26 gpm @ 10.6 psi (98.4 L/min @ 0.73 Bar) C1Z 18262 VK602 3/4 20 8.0 115.2 18'x 18'(5.5 m 5.5 m) 33 gpm @ 17.0 psi (124.9 L/min @ 1.17 Bar) C1Z 18262 VK602 3/4 20 8.0 115.2 20'x 20' (6.1 m 6.1 m) 40 opm @25.0 psi (151.4 L/min @ 1.72 Bar) I I B1Y I d'ltt rn/ (Contact Local ril71FIOffice) Standard Response Applications' cULus5 07077 VK602 3/4 20 8.0 115.2 20'x 20'(6.1 m 6.1 m) 40 gpm @25.0 psi (151.4 Llmin @ 1.72 Bar) A1Z Quick Response App ications 07077 VK602 3/4 20 8.0 115.2 16'x 16'(4.9 m x 4.9 m) 26 gpm 10.6 psi (98.4 L/min @ 0.73 Bar) C1Z 07077 VK602 3/4 20 8.0 115.2 18'x 18'(5.5 m 5.5 m) 33 gpm @ 17.0 psi (124.9 L/min @ 1.17 Bar) C1Z 07077 VK602 3/4 20 8.0 115.2 20'x 20' (6.1 m 6.1 m) 40 gpm @ 25.0 psi (151.4 Lfmin @ 1.72 Bar) B1Y Approved Escutcheons Sprinkler Temperature Ratings Approved Finishes V - Standard surface-mounted escutcheons or the Viking Micro- A- 155 ¶ (68 °C) and 175°F (79 °C) 1 - Brass, Chrome, White fasts Model F-i Adjustable Escutcheon9 B - 135 °F (57 °C) Polyester and Black Z - Standard surface-mounted escutcheons or the Viking Micro- C - 135 °F (57 °C), 155°F (68'C), and 175 °F (79 °C) Polyester fast' Model F-i Adjustable Escutcheon', or recessed with the Micromatic® Model E-i or E-2 Recessed Escutcheon Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. OthEr approvals may be in process. Check with the manufacturer for any additional approvals. For areas of coverage smaller than shown, use the 'Minimum Water Supply Requirement" for the next larger area listed with sprinklers of similar K- factor. Flows and pressures listed are per sprinkler. Listed by Underwriter's Laboratories, Inc. for use in the U.S. and Canada for Light Hazard occupancies with smooth, flat, horizontal ceilings only. cULus Listings are limited to Light Hazard occupancies, where albwed by the installation standards being applied. Form No. F102412 18.10.18 Rev 18.2.P65 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. DESIGN CRITERIA - UL Aleo refer to Apprcial CrO cULus Listing Requirements: Standard/Quick Response Extended Coverage Pendent Sprinkler SIN VK602 is cULus Listed as indicated in the Approval Chart for installation in ac- cordance with the latest edition of NFPA 13 for extended coverage pendent spray sprinklers: Limited to Light Hazard occupancies, where allowed by the installation standards being applied, with smooth, flat, horizontal ceilings only. Minimum spacing allowed is 8 ft. (2.4 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured per- pendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for extended coverage pendent spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Step 1 Caref wrench sidew the sprink(ei and protec (Note the oriri L. u i u r i ji- the shield in the wrench,) p 2 Carefully press the wrench upward and ensure engagement with the sprinkler wrench flats rm Sprinkler Wrench 3577W/B** must be used for Installing recessed sprinkler VK600 and VK602 A 1/2' ratchet is quired (not available from Viking). Figure 2: Wrench 13577W/B for Recessed Pendent Sprinkler VK602 Form No. F_102412 18.10.18 Rev 18.2.P65 Page 5 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Approval Chart 2 (FM) T, KEY Quick Response Extended Coverage Pendent Sprinkler AlX - -. Maximum 175 PSI (12 Bar) WWP --- ----------- --_--- NPT Thread Nominal Maximum Areas FM Approvals3 Sprinkler Base SIN Size K-Factor of Coverage Minimum Water Supply Requirements4 (Refer also to Design Part Number' Flow/Pressure Inches Imm U.S. metric2 (Length x Width) Criteria below.) 18262 VK602 3/4 20 8.0 115.2 16'x 16'(4.9 m 4.9 m) 26 gpm @ 10.6 psi (98.4 Umin @0.73 Bar) A1Z 18262 VK602 3/4 20 8.0 115.2 18'x 18'(5.5 m 5.5 m) 33 gpm @ 17.0 psi (124.9 Umin @ 1.17 Bar) A1Z 18262 VK602 3/4 20 8.0 115.2 20'x 20' (6.1 m 6.1 m) 40 gpm @25.0 psi (151.4 Umin @ 1.72 Bar) A1Z Sprinkler Temperature Ratings Approved Finishes Approved Escutcheons A- 135 F (57 CC), 155 °F (68 CC), and 1 - Brass, Chrome, White Poly-ester, Z - Standard sulace-mounted escutcheons or the Viking Microfast 175 F (79 °C) and Black Polyester Model F-i Adjustable Escutcheon, or recessed with the Micro- matic® Mode! E-1 or E-2 Recessed Escutcheon Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement' for the next larger area listed with sprinklers of similar K- factor. Flows and pressures listed are per sprinkler. DESIGN CRITERIA - FM 'Also refel Tr /;proal Choil 2 above. FM Aooroval Requirements: Quick Response Extended Coverage Pendent Sprinkler VK602 is FM Approved as quick response Won-Storage extended coverage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA. LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_102412 18.10.18 Rev 18.2.P65 (54 mm) I 2" (51 mm) Maximum 1-1/8' (28,6 mm) Minimum Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Ceiling Opening Size: 2-5/16' (58,7 mm) minimum 2-1/2' (63,5 mm) maximum 2-1/8' (54 mm) 2-3/8' (60 mm) 1-3/8' (35 mm) Pendent Sprinkler 18262 (VK602) 2' 1-1/2' (32 mm) (51 mm) Minimum Maximum Standard 1/8' (3,1 mm) surface-mounted escutcheon Installed with a Microfast Model F-i Adjustable Escutcheon * Note: At maximum, adapter is exposed 1/2' (12,7 mm) from face of ceiling. Figure 3: Sprinkler VK602 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Ceiling Opening Size: 2-5/16" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum (54 mm) 1-3/4" 1-1/8" (28.6 mm) (45 mm) Minimum Maximum Installed with a Micr'omatic Model E-1 Recessed Escutcheon Installed with a Model E-2 Thread-on Recessed Escutcheon Figure 4: Sprinkler VK602 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_102412 18.10.18 Rev 18.2.P65 Replaces Form No. F 102412 Rev 18.2 (Added P65 Warning.) Page 1 of 4 N II(IF1G® 4 MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16" (56 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C 19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° =A, 155/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 ¶/68 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_052114 17.10.05 Rev 17.1 Replaces Form No. F_052114 Rev 15.2 (Replaced wrench 10896W/B with 21475M/B) Page 2 of 4 N 1FI F1G8 MICROFASP QUICK II1[Uu1M.. RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The 'liking Microfase Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1 : AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature S'prinklar Nominal Maximuii Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature2 Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 C) Yellow Intermediate 200 F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 ¶ (107 C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Figure 1: Standard Sprinkler Wrench 21475M1B Form No. F_052114 17.10.05 Rev 17.1 Page 3 of 4 N II(II%1c® MICROFAST® QUICK 4 l:II[u'7w RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Terntr. KEl Microfast Quick Response - Firish Upright Sprinkler VK300 AiX 4 Es1chess ( PnJicbe) Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals3 SIN Number1 NPT BSP U.S. metric" Inches I mm cULus I VdS I LPCB NYC- CE 12978 VK300 1/2" 1 15 mm 5.6 80.6 2-3/16 1 56 Al, B2 - - See footnote 7. - Limited VAvailability f 06661B I VK300 1/2" I 15 mm 5.6 I 80.6 2-3/16 56 1 Al, B2 I - - ISee footnote 7.I - Approved Temperature Ratings Approved Finishes A- 135°F (57 °C) 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and 1 - Brass, Chrome, White Polyester".", and Black Polyester56 B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) - Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 'Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. Meets New York City requirements, effective July 1, 2006 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast5 Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 17.10.05 Rev 17.1 Page 4 of 4 N IIII4,1c® MICROFAST® QUICK l:II[u.LW RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Trpet KEY Microfast-.Quic I, Response Al X 4 Es€Ir cf .ppJei Upright Sprinkler VK300 Maximum 175 PSI (12bar) WWP Base Part Thread Size Nominal K-Factor Overall Length FM Approvals' Number1 SIN NPT BSP U.S. metri0 (Refer also to Design Criteria below.) Inches mm 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 tNOTICE Product r Limited Availability aLocal Viking IJiI! 06661B VK300 1 1/2" 1 15 mm 5.6 80.6 2-3/16 56 Al, B2 Approved Temperature Ratings Approved Finishes A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and 286°F (141°C) 1 - Brass, Chrome, White Polyester", and Black B - 155°F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Polyester 2 - Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. 6 FM approved as corrosion resistant. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM Arrnroval Requirements: The Microfast Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 17.10.05 Rev 17.1 Replaces Form No. F_052114 Rev 15.2 (Replaced wrench 10896W/B with 21475M/B) Page 1 of 6 N II(II1G® 4 MICROFAST® QUICK III[UILW RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small thermo- sensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatingscan be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009 and G414010 Qpc~o LPCB Approved CE CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-50021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C 19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, 286°F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W1B with 21475M/B) Page 2 of 6 N iIIr1c® MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B (available since 2017). Wrench for Recessed Pendent Sprinklers: Part No. 13655W1B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2, ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. - Wrench Flat Protective Sprinkler Cap— Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_033314 17.10.05 Rev 17.2 Page 3 of 6 N II(IF1G R MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient 1 Classification Temperature Rating' Ceiling Temperature' Bulb Color U Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/B** A 1/2" ratchet is require7d . . -. for recessed pendent sprinklers ** (not available from Viking) Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 17.10.05 Rev 17.2 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Temperature KEY The Viking Microfast Quick Response Finh Pendent Sprinkler VK302 AX - Esctcc app(rcb6 Maximum 175 PSI (12 Bar) WWP Base Snrunkler Thread Size Nominal Overall Listings and Approvals3 Part _J SIN Style I K-Factor Length (Refer also to Design Criteria.) Number' NPT ______ BSP U.S. metric2 Inches mm cULus4 VdS LPCB (E 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, 131Y, 02, C2X Al A1Z, BlY D1Z, C1Y - - 19780 VK302 Pendent 1/2" - 5.6 80.6 2-1/4 58 - - - - - 03 21354 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 -- -- - -- - D3 4VP CE - Prod6&~gelow -Limited Availability (Contact T.1//t 06662B VK302 Pendent 1/2 15mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X - - - -- 18021 VK302 I Pendent 1 1/2" 115mm 5.6 1 80.6 1 2-1/4 58 A1X,131Y Al A1X,B1Y I D1X, C1Y8 01X,C1Y - Approved Temperature Ratings - Approved Finishes Approved Escutcheons A- 135 "F (57 °C), 155 "F (68 °C), 175 "F 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 "C), 200 "F (93 °C), 286 °F (141 "C) Polyester56, Black Polyes- Viking Micromatic® Model E-1 Recessed Escutcheon B - 135 °F (57 °C), 155 "F (68 °C), 175 °F ter5'6 Y - Standard surface-mounted escutcheon or the (79 "C), and 200 °F (93 °C) 2 - ENT' Viking Microfast® Model F-1 Adjustable Escutcheon, or recessed with the Viking Micro- C - 155 "F (68 "C) 175 "F (79 "C), and 3 - Chrome matic® Model E-1, E-2, or E-3 Recessed Escutcheon 200 °F (93 °C) Z - Standard surface-mounted escutcheon or the D -155 °F (68 °C), 175 °F (79 °C), 200 "F Viking Microfast® Model F-i Adjustable Escutcheon (93 °C), 286 "F (141 °C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 8 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. 8 CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above. cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. Form No. F_033314 17.10.05 Rev 17.2 Page 5 of 6 N II(IFt1c ® MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) KEY The Viking Microfast Quick Response A1 X4— trcr Pendent Sprinkler VK302 Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number1 SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric2 Inches MM 12979 VK302 Pendent 1/2' 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 Product Below Limited VAvailability TTIIT7 Viking Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 1 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 I Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings X - Standard surface-mounted escutcheon or the A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 CC), 200 °F Viking Micromatic Model E-i Recessed (93 °C), 286 °F (141 °C) Approved Finishes Escutcheon B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and I -Brass, Chrome, White Polyester', Y - Standard surface-mounted escutcheon or the 200 °F (93 C) and Black Polyester4 Viking Microfast Model F-i Adjustable Escutcheon, C - 155 °F (68 °C), 175 °F (79 °C), 200 ¶ (93 CC), 286 2 - ENT' or recessed with the Viking Micromatic® Model E-i °F (141 °C) or E-2 Recessed Escutcheon D - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon or the Viking Microfast® Model F-i Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 17.10.05 Rev 17.2 Page 6 of 6 N I 1(1 1'e ' MICROFAST® QUICK 4 iiiIU'LW RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 2-5/16" (59 mm) minimum 1/2" '• 2-1/2" (64 mm) maximum (15 mm) NPT (54mm) 21/4" 1-314" 2' 1(38 mm) (57 mm) - (51 mm) J, Mm. I (45 mm) Max. -' y Installed with a.standard Installed with a Microfast Note: At maximum, adapter 1/8" surface-mounted Model F-i Adjustable is exposed 1/2" (13 mm) escutcheon Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 4 1314 (45 mm) Max. Installed with a Model E-I Recessed Escutcheon 2-1,8 54 mm L I- 1-1/8" 4 : (29 mm) 211" Mm. (51 mm) •...- Max. • ______ Installed with a Model E-2 Thread-on Recessed Escutcheon (29 mm) Mm. Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W/B with 21475M/B) Page 1 of 7 MIRAGE® STANDARD AND N1, VJ QR CONCEALED PENDENT SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile cover assembly that provides up to %" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is cULus Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. LISTINGS AND APPROVALS cULus Listed: Category VNIV > FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 Vd (AflOA(V)1 VU ?'qJ1Ji JVU. 'I LiiiI.OI ?UUUU I LPCB Approved: Ref. No. 096e/12 (E CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart 1 Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C 19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Form No. F_103005 18.04.12 Rev 18.1 Replaces Form No. F_103005 Rev 17.1 (added stainless steel cover plates) Page 2 of 7 R MIRAGE® STANDARD AND QR CONCEALED PENDENT 'SqI I 1(1 ISIGI l:I1[uuLIv SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Yoke: Phosphor Bronze LJNS-051000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C 11000 or Stainless Steel UNS-530400 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463 - HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 "F (68 °C) = B, 175 "F (79 °C) = D, 200 °F (93 "C) = E For example, sprinkler VK463 with a 155 °F (68 "C) temperature rating = 13667AB. Standard Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-M, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135 "F (57 "C) UL (139 "F (59 "C) FM and LPCB) =A, 165 °F (74 "C) = C For example, cover 13504 with a Polished Chrome finish and a 165 "F (74 "C) temperature rating = 13504FC. Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Temperature Suffix: 135 "F (57 "C) UL (139 "F (59 "C) FM and LPCB) = A, 165 "F (74 "C) = C For example, cover 21876 with a 165 "F (74 "C) temperature rating = 21876C NOTE: The cULus Listings for the square cover plate 15394 are for the 135 "F (57 "C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) ""Requires a %" ratchet'(not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_103005 18.04.12 Rev 18.1 Page 3 of 7 ft MIRAGE® STANDARD AND 'sql I FI I''c';I QR CONCEALED PENDENT SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLEIWVhlI:1I $SPRINKLER TEMPERATURE RATINGS ANDIllE1:l*1 Sprinkler Sprinkler Maximum Cover Plate Large Cover Square Cover Temperature Nominal Ambient Temperature Rating of Cover Base Part Plate Base Part Plate Base Part Bulb Color Classification Temperature Ceiling Assembly (Required) Number' j Number' Number Rating Temperaire2 MW 135 °F (57 °C) cULus Ordinary 155 °F (68° C) 100 °F (38 °C) 13504 or 218761 13642 or 218751 15394 Red 139 °F (59 °C) FM and LPCB Intermediate 175 °F (79° C) 150 °F (65° C) 165 °F (74 °C) 11350401 21876 13642 or 2187511 15394 1 Yellow Intermediate 200 °F (93° C) 150 °F (65° C) 1 165 °F (74 °C) 11350401 21876 13642 or 218751 1 15394 1 Green Cover Plate Finishes': Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Sprinkler Finishes: Brass and ENT Corrosion Resistant Coatings4: ENT Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 4 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. Stainless Steel versions are not available with any finishes or paint. CUS7-0 - 0 C) I— 0 0 Nll(ING All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers 3-5116" (84 mm) Figure 2: Square Cover Assembly 15394 Form No. F_103005 18.04.12 Rev 18.1 Page 4 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT 'iil I FJ l:II[u.7..w SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com A nnroval Chart I UL jrkI - - r'r' ! / Mirage Conceafd Pendent Sprinklers VK462 and VK463 AW14 Cov PIae KEY Thread Nominal Maximum Listings and Approvals4 Sprinkler SIN Size K-Factor Water Working (Refer also to Design Criteria) Inch mm U.S. metric cULus' NYC I VdS7 LPCB CE Base Part No.' Pressure Standard Response Applications 13503A VK462 1/2" 5.6 80.6 175 psi (12 bar) -- AY1, CZ1 AY1, BZ1 AY1, CZ18 - 19785A VK462 1/2" - 5.6 80.6 175 psi (12 bar) -- - - - - AY2, CZ2 21356A VK462 -- 15 1 5.6 80.6 175 psi (12 bar) -- - - - AY2, CZ2 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1,AV1, BX16 - - - - 13503JN11 VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1,AV1, BX16 - - -- - AS3, BT3 13667A VK463 1/2" 15 56 80.6 250 psi (17.2bar)3 AV1,BX1 AV1, BX16 -- -- -- - Cover Plate Assembly Temperature Ratings',9 S - 135 °F (57 °C) cover 21876 or 21875 (large diameter) Cover Plate Assembly Finishes10 Sprinkler Temperature Ratings T - 165 "F (74 °C) cover 21876 or 21875 (large diameter) 1 - Polished Chrome, Brushed Chrome, Bright Brass, A - 155 °F (68 °C) V - 135 °F (57 "C) cULus Listed cover 13504, 13642 (large diameter), Antique Brass, Brushed Brass, Brushed Copper, B - 175 "F (79 "C) and 200 "F (93 °C) or 15394 (square cover plate) Painted White, Painted Ivory, or Painted Black C -200 "F (93 "c) X - 165 "F (74 "C) cover 13504, or 13642 (large diameter) 2 - Brass Y - 135 °F (57 °C) cover 13504 LPCB Approved as 139 "F (59 "C) 3 - Stainless Steel Z - 165 "F (74 "C) cover 13504 Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A1:2001 + A2:2004 + A3:2006, Certificate G4080021. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. The 135/139 "F cover has an orange label. The 165 °F (74 °C) cover has a white label. 15 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. cULus Listed as corrosion resistant. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No. F103005 18.04.12 Rev 18.1 Page 5 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT \J I KJ 4 l:I1[.Lu.LI SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1) cULus Listing Requirements; Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Anoroval Requirements: The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupan- cies, except in OH4. NOTES: Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: Prepare the sprinkler key. Remove the plastic cover. Hold the sprinkler with the wrench and fasten it. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 18.04.12 Rev 18.1 Page 6 of 7 MIRAGE® STANDARD AND J I I(J '4Jj QR CONCEALED PENDENT SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart 2 (FM) a IQ • ci H' Mirage Standard Response Concealed Pendent Sprinkler VK462 AW1 Gr Iat KEY Sprinkler Base NPT Thread Size Nominal K-Factor Maximum FM Approvals' Part No.' I I SIN I I I I I Water Working I (Refer also to Design Criteria below.) I Inch I mm I U.S. I metric' I Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AWl, BX1,AY2, BZ2 Cover Plate Assembly Temperature Ratings' .4 Cover Plate Assembly Finishes' Sprinkler Temperature Ratings Y- 139°F (59 °C) cover 21875 or 21876 Z - 165 °F (74 °C) cover 21875 or 21876 1 - Polished Chrome, Brushed Chrome, Bright A- 155°F (68 °C) W- 139°F (59 °C) cover 13504, 13642 (large diameter), or Brass, Antique Brass, Brushed Brass, B - 175°F (79 °C) and 200°F (93 °C) 15394 (square cover plate) Brushed Copper, Painted White, Painted X - 165 °F (74 °C) cover 13504, 13642 (large diameter), or Ivory, or Painted Black 15394 (square cover plate) 2 - Stainless Steel Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additiona approvals. The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA - FM Also refer to Approval Chart 2 above lf,j,Jxirt IitiTli irti ioiii Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 18.04.12 Rev 18.1 Page 7 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT 'sil II I"lGI SPRINKLER VK462 AND HP SPRINKLER VK463 (K56) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818.1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Sprinkler and Adapter Assembly Protective cap - Sprinkler Wrench removed Part No. 14047W1B** Use wrench 14047W1B** 2-1/4" (57 mm) diameter opening required in the L 4 ceiling. Step I Carefully slide the wrench sideways around the deflector and pins NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise I to 1-1/2 turns beyond finger tight. Step 2 Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat -& r Sprinkler / frame arms :- Figure 3: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) - 1/2" (15 mm) NPT 2.9/1665 LMaximum- 2.1/1611 52i I Minimum zZ 04 EE - 2-3/4" (70 mm) or NOTE: Upon sprinkler activation, the deflector descends 3-5/16" (84 mm) to approximately 13/16" (21 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F 103005 18.04.12 Rev 18.1 Replaces Form No. F_103005 Rev 17.1 (added stainless steel cover plates) 71 ISIDEWINDEW FOR WOOD - H 7k.i 7VT7Itik'ii Application Product Features Jot less than 2" ncminal width No pre-drilling required. .. -' (1-12) up to 31/2" pipe; not less than 3'(2-112") cortical width 4"& 5' pipe • Quick to install using the Sammy I Fluoros: Nut Driver with an 18V cordless I Minimum 2-112 7tottomr drill/driver, brunch lines. Minimum from bat- tom for main lines. Exction: This • Saves time from traditional -I requirement shall not apply to 2' or methods. Neker nailing strips renh g on top of steel beams. - - -- • Reduces installation costs. Made in the U.S.A. Water a wdeo demonstraba at Approvals www:twbuildex corn Part Model Screw Ultimate UL Test Box ber Descriptions Pullout (lbs) Load (lbs) City o iyui,tiLA 1 13 F 114' 8010957 ,w-; ?nn 1'4x2 1 13 1 802395 114o 1 822195 •'. 14x2 58 - -. 8073925 23 850 - •• 1 Rfl2?92 ., 2-1 2 .,, .W Red , SW. 30 3 18 125 Nut Driver Part #8114910 May require pre-drilling. .onsuft joist manufacturer. • - TIM SAMMYS SWIVEL HEAD FOR WOOD Swivel Application 17ItT1DIs Product Features wwom Eliminates distortion of threaded rod. Shl-STMIff 20 ___________ - • Accommodates up to 3 Y2" / x 12 pitch roof. ________________ • Allows 17° deflection from vertical. Hawep—' ens ________ Saves time from traditional methods. • Reduces installation costs. • .K;--/(±' •Made in the U.S.A. Approvals Rod Part Model Screw 2imate UL Test Load FM Test Min Box Case Size Number Descriptions PUl out (lbs) (lbs) Load (lbs) Thickness City City Sim, Mou Al. 414 Black • 4? 31 CiOQQC 1ST 20 • 1/4 Y 2 1257 (Fir) 1050 1b75 25 125 Pal # 81139 ioL Q.rri> 38 - 19530 14x 3 1500 14 25 125 00 JEL 30 8269957 SH-GST,C°120 SlOe 134 1 • if vertinl 850 @ 45• 25 125 830305 • , L •,l, . May requ In Dre-drdling. onsutt joist mat • ll•r Orrtrlqn Driver : v 92/3910 WMYS FOR FOOD -. Not less than 2' nominal width A Not less than 3 nominal thickness (2-112') (depth or side of vertical member) Wood Flooring No pre-drilling required. 'Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. 'Reduces installation costs. 'Made in the U.S.A. Wv/rh a video demovs005va . wwwitwbuildexcomJ 114' 8002957 GST 130 114x 1' 210 (7/16OSB) 25 125 1/4' 8003957 PET 381/ 114v 9' 1760 20 8004957 1r 2050 Q 3/8 8007957 GOT 0 1A 1 210 )6B( 300 25 125 38 8008957 GST 20 114 x 2 1760 (Fir) 850 25 125 3/8 8068925 PST 10691/4x2 1760 (Fir) 850 25 125 3/8 80091/91 flIT 20-/fl 2-1/2r 2111/ _3)8_x (Fir) 1500 25 125 #14 Black G3 K* 38 8010 143 (Fr) 1500 1475 25 125 Nut Driver 38 8059 - 1 14 x 3 2060 (Fir) 25 125 Part #8113910 801 / 114x 4 -. 2180 (Fir) 1/2 8013 . 1/4v2 1760 (Fir) 29 125 0014925 . 3/8x 2-12' 2113 (Fr) 25 125 1/2' 8015925 GST3 1I4x3' 2275 (Fir) . 25 125 414 SW Red Nut Driver Port#8114910 KN EW, MADE IN U.S.A V Ø05'. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feuture which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. l:staiatiss is then compteve. Warranty requires the use of the appropriate nut driver for installations. lk H-anaermate+ EWA-LT,. 4 ENGINEERED BY-Powers-. i•St,,,le • 1?- iIu THREAD PROFILE low torque, fast installation, full concrete - engagement nSTANDARD no need for ' specaity bit for installation 11 Pullout *T flj 1 25% Fasts for Concre'.e ii S I I 1' 4xl -5/8" concrete cc ow (w5ti $/8 coupler heudi versus 3/8 Drop-in anchor CAT * .i!rijJrir1 PFM22 11100 PEM2211200 PFM2211250 PFM1421 000 PFM1421050 11IfiIT PFM2281300 TTH1T PFM2271 050 EXTERNAL 3/8" THREAD for attaching directly to anchor ( Oak AnAlk M I M AF., air— iiiw 1 06W F' 45 FS VOL EL ft HASS 1-42 SITE Ul 1/5TH Hngermate+ For Concrete - Internally Threaded jIJI 1 x 1-4 B (121' 21 Verti I 14 2 1 1- ST SO Verti dl 3/8" 125 I 1 2-1 C I 5 1 6 21 t Hngermate+ For Concrete - Externally Threaded ME0001 1 4 1 -2 0 - 5" "i 1 '1 - 125 11 x2-1C "ie'icaI 22 2' 125 Hngermate+ Pivot For Concrete - Angled Applications PFM228130 114x2 H-SBT 45T20 VariaH# 3/8' 2 - 125 Hangermale+ Suspender For Concrete - Dual-Directional it., >' - ' - Vt. H 12 The Complete Anchoring Solution - Installation Accessories and Tools WJII F 4CF 1U. HJJGEHM/21E Sm VSTR ij' 1,010101111110 t!AIII1t0I 11 L iv Concrete F I H r 5 III10JII 1'16 Liver I nn r '0 H 11 flr'j S 221 E,to'ni2T1iroirie - S - 24I12II V 'I 'Ii'Jt I pivni ' 5 _ 1 21,tVrrdl 4 Ht I 4 DW5517 It '4 x B 1 usible nqt I SLS— Full Head mrL Mn' I' III H x BikinI SUB-F I , I y f r F '.' I r 1211$II /',it11 fur I afiging 12 n0 '22 1 1 0 ['02111 '2 '21' S'LIiB e, ' H' I-1 Fj ill nor B 1/5< XP A 1411 rn -i-Toni I iHOt Driver LB MAX' it iin,l.n InI1Ji.121''-ii - IIiI I •i(lp 1 -' ( ', , ("A ItteF "Hill 111i, '11i, '- , , ' C I- -,-"I )... I'll 'I 1 ,',JF _a'll .1' I 77 TYPE 17 GIMLET easy material removai,no 1Dual_Fiend pre-drilling - Point Etyle required Single Piece Design — Dil W000 DVIIVER spin elf feature helps reduce over driving CAT FFM2251000 5FM2251050 FFM22511 00 5FM225 1150 TM2251200 TM225125) fl:M2251300 Ism 5i226i 000 5FM2261 050 5FM226 1100 5FM226 1150 IIYITj1TE ,1:M2281100 FfM2271000 IiM2251500 JEH RIP 1I II. 5/VIMOS V'5[ _L 2 HAl S [01[ 'OlE P 1/SIR Q ]' Hangermate For Wood - Vertical PFM2251 000 1/4 I GST_ I 0 L/, 25 12 I 1/4 3ST1O '' 25 1 9 PFM2251 100 1/4 2 51 20 2 25 25 51,16" x 2-1 2 AkOft H fl 25 8 0 25 122 1 0 51 iJ 1i I S 1 x 4 - "Ortical 3/3' 25 125 I 216 2-112 G5T IA,rtiGal 1 IS 125 Hangermate For Wood - Horizontal 1 4 > 1 5 200 Hof infltol 1 0 1 x 1 PC/u 11 H)f ourItIl 11)7) DO 1,1 4 x2 SC/i, 21 PFM2261 100 Hri nnt,0 20 125 I 510 2-12 /JC0-35 Hof l(Jl 'i 2 105 Hangermate Pivot For Wood - Angled Applications PFM '44.IilIII 1 2 SH 1 Or ij 01 10 Hangermate Suspender For Wood - Dual-Directional - âDhII,I 5 1 21 1 - ( r iiL[ h 1 5 Harigermate For Wood - Acoustical Ceiling Screw Eyelet ,' x )\5j 12 r1ic& Eyet1H2 12 [Inrizontal 3, '6' Tkii Complete Anchoring Solution - Installation Accessories and Tools DES"RITIDI HANGERMATE If' VIITR 11 _______ t1iPh?(IiILII1 Vccj C:K'S [H1i Pr' Hr 1N ti*i_KitiII ruc/El •lE[ Dwel St,srp, (Jef 1 Hi: L vet vot I Ceiling Scrcr: E,'O t Driver Accustical L 1-i t'P4i1l Pole Tod KIT Pro Hanger 4 it or 1 0'iu irojtr K 'i MAX XH Lithium 1(~n S u less Compact - II I n i XR (ii in I: Fier ii eO Drilh Dr ve• KS Ii MAX*XR Lithium Ln Br.r' c-s 0 iir Hiri I mu I - 1Vii1OZIUOH II 31St'.! 01 x"61 iiLioj MOI SI$HL - MJVJ.Tfl3S t p s uici UOII38UU03 pos N9SO L2ZVJJc cI 140E LL'ZZWIJ IIIrt NOLZWa - NOLLEMM L8JdC N-Oe LI7?U C : LLfr7J c - Rr IL (JLbJdd FL LJid - FLLLHc JLLJUd WaI'RiEEI :; anti p0jVifl eanp LIDIS aJild ILJS YI einaj uids IX 6uij-eid 1 I.NIOd 91mw0-n3s; I VI1 HE C'1 117 10'J 'J 45ulx1YS 'H [ L 4 HA 111 FICj D 11LE 313 1 "-J:) 311 Hangermate For Steel - Vertical 1 l'- ' ifl 55TH 111 Vert 1 H 12 PFM2231 100 1 i-/3 4 3 - 1- 1 1 iii [HTR I Surl H 1-2C.5 -12u 55TH-12 Vert Hi 1 1 x 1-1 H r :. DSTR r H '1 1' x 1 I H - Vert 1,11 25 1 H 1 A-uI x -i .33 LII DST 1 S r cal 25 12 _I 1 -H H 431 '-'j HI LL11 3 H 12 Steel - Horizontal 1 -i-J < 43 SLAIJ 11) Hur 7C t 3 22 1 7 - ON 1 H #1 nut HiLotF 4: 24 125 P 1 4 lix 1 1 H - Hr I (I Iii 12n -ui - H n - H2ru'tji .3 H 12n 1 14 2u x 1 1 2H S HDI u tul n 125 1-20x H) 45 11111r, $2/UI -I H r: Iii H H Hangermate Pivot For Steel - Angled Applications I 1'25'#2 SHUSTR1 v'rnu I 12-201-') Ix H-)H 'j'rrlH 12' 11-'l x 43 - irixhie 3/3 .4 Hanqermate Suspender For Steel - Dual-Directional U]/-~-21'x 'H lilt PFM 1 1- - " ' i - Surt. i- H I" '4$OL i-2ix-1 I ' ri. - li'rt.5 '' ' I 12 Hangermate For Steel - Acoustical Ceiling Screw Eyelet 4tH H r;. EH 11:5 - 1 Vol 3/16 T Ii 2000 rpm' :r, C j The Complete Anchoring Solution - Installation Accessories and Tools I' IF Ii5 HAN E i'IA1 P Q,12 - 4 '1 1IP4I1iI Sjexj nukot S unri Rod Hanger ________ i4IIKIlIlI tHc.t rI LI I $uu5n' u 1 LIiIQ1II vc,.t Drivr Pint it I Irri r':i 13t it 'fly I /t'. I I xi 1. it SI P 1 Hx'q- r 1 5 $IDMII 4121'ter Ix' ongin 112 od 5 tu 12 A I fjW V MAY- ",i LIt u'ri hiIFrIri xl- 1.1[nl '[ri'r'rl' PIIl1IPJ .1 SAX' H 1,/,- I jx' I ir' H [,'Fl,,,,, K - ureit v t 1 ', - I 1 ?Q volts, No - I I - A rj LI decree L desi fb for Pivot Inslallation Ikir & Bit Reference t:I DE+ DRI.E P vat For Concrete 1 1 FM 1 P vot For Wood FM Ptvot For Steel I 4- 1 PFM220125 II 4 5 PFM220125 I PFM220125 Hangermate Specialty Rod Hanging Anchors )' •4.!: ti Suspender 41F Ar I I I UL I1 1 I MULTIPLE THREADS different thread H L . and point styles Al 4J READ - for thread engnien ugeoder For - I)f 4cuncret LUMBER age Concrete - 3Fvt.71O5O E~uspehder For S __________ Euspender For Steel — tone part for vertil or , horizontal applicpn H. __ %EWALT. ENGINEERED BY'Powers' APPROVALS ____________________ (!) <2> Hangermate+ For Concrete - Internally Threaded ULTIMATE PIPE PIPE RS OD L IfI DESCRIFT Li HANG IZE DRIVER TENSILE LOAD LOAD SIZE LOAD SIZE ICC-ES (LBS)* )AII$$I 1/4 x -518 Vertical 1/4 F !. PFM1491050 2,835 - - 4° 1,475 ESR-3889 xl-518 Vertical 3/8 n 1/4 I PFM14911DU 2 835 - - 4" 1,475 ESR-3889 1/4 x 2-1/2' Vertical 3'9" PFM1491100 3,650 - - 4' 1,475 ESR-3889 do 250pm uncracked concrete L. Hangerinate+ For Concrete * Externally Threaded 'kVAI!kIIIW,I 1/4' x 1-5/8 Vertical 3/8' DW22862 2,835 1/4 2-1/2 Vertical 3/8" 0W22862 3,650 - - 4" - - 4" 1,475 ESR-3889 1,475 ESR-3889 I in 2 500pm incrack0 concfete Haflgermate+ Pivctt For Concrete - Angled Applications OJjPcj'I'I 1/4 x 2 Variable 3/8' PFM2201250 2,830 (Vert.) 990(45°) - - - - - - - - - - In Copsi uncracked concrete Hanqennaté+ Susiender For Concrete - Dual-Directional 2,188 (Vert.) I ;'1A1e1l1 5/16" x 2-1/4" *-rt c Him 3/8" PFM2201300 I 2,767 (Horz.) - - 4" j - - 4 1,475 - 1 47i - 'In 3,650psi uncracked concrete Hangennate+ For Wood -Vertical 1/4'x 2' Vertical 1/4' PFM2201150 1.510 - - - - - t s 1/4" xl' Vertical 3/8' PFM2201150 685 - - - - - 1/4' x2 Vertical 3/8' PFM220115J 1510 3 I 1SF - - - 5/16' ti 2-1/2" Vertical 3/8" PFM2201150 2,670 4' 1,500 1 475 - II 1/4'x 3" Vertical S 5FM2201150 2.075 3' 1,050 - - - a I 1/4' x 4' Vertical 3/8' PFM2201150 2,075 3 1,050 - - - ii 15/16"-x 2-1/2 Vertical 1/2" PFM22L 1150 2,670 - - - - - . . *Ultimate Loads In Douglas Fir Hangermate+ Foi Wood - Horizontal N3 1/4 ri xl" Hon, idol 1/4" PFM2201150 635 - - I 1/4 xl' Horizontal 3/8' PFM2201150 685 - - - - - $ $ 1/4 x 2' Horizontal 3/F PFM2201150 1,800 3' 1,050 - - - I 5/16" x 2-1/2' horizontal 3/8' PFM2201150 1,450 3 1,050 - - - 'Ultimate Loads In Douglas Fir Hauqermate+ Pivot For Wood - Angled Applications 1,470 (Vert.) - - - - - ;r#pIILiIiI 1/4 x 2" Variable 318" PFM2201250 1,154(45°) - - - I iJltimate Loads In Douglas Fir Hangermate+ Suspender For Wood - Dual-Directional 5/16' x 2-1/4" \rert. & Horz. 3/8' PFM2201300 2,487 - - " 1,475 - 'Ultimate Loads In Douglas Fir FM Load applies to vertical only I Hangermate+ For Wood - Acoustical Ceiling Screw Eyelet 3/16" x 3" ert. & Horz 216' PFM2201350 883 Ut mate Loads In Douq1 APPROVALS (@ Hanijermate+ For Steel - Vertical ILlS M,IE LE050IRTI' IL 5H ORIVER THI/ [H LLAD I 11 i.F THICK. 546 1HK, THILKHESH KâMI$1IIsI 1 1-211 'rt p6112 10126/I ThI 12fl 2175 - - - - - 4-2lxl 43 Vii ['F51lS,1)11U 6565 121 2 3 7 5 C, 1' 5 V 4 OUSU' VIDII 1 1-2fl 1" #3fltit 'P Ft. 557 PP1L1200 0,060 U 2O 4 6560 C 5") V Il12 5 12111 ffJ$iIIII 14 -1l1-1 11 V'V 573 SF11 2112'lI 515- 11270 3f75 fl '33"l V 4 361,1 11 1 L 1 11 1 e Ft, 3 PP3lUL120] 111:1 52511 03 3 L' V 1 fl ' 12j 4126>1 2 VH1 30 5F012H12111 J1H 1250 2,375 V 1 LIUIH - iII 1 4-10 x 1-1 2 4 3 n. Vrt B' 66112261200 4I Ps 1. 250 4,660 C HS I V 1 U OPt' - - 14-2'1x2 57' Hri "''-i 6FV17)121)1[1 F U 3 55R1 '''5J 53 1/ 4 1 2 5 Hanqerniate+ For Steel - Horizontal RWIII$II I 1 Hors. 3 PF312s[ 1231 0000 rj 2120 2 117C.) 112 H - - - - IW1l 4U-u> b"o,' 157i,s ,.HI PF'i12L'12U1 1115 3250 0 u I 11 6 4 ullU - 1601 .121l 41 Hr 51 PH'7211''13 lIPS J,''50 1 5 7 0 C, ll H - - - - 1PIWI 1/4-20 x -1/2' #3,1 'L Hijr Z. 3/8' PFM2201200 SOb 1 1 256 5 310 11 H 4 0 061 4 lb a PWA$III 1-'12x1-572 45 Huz 0 F'F012'0121111 Qtj 3575! 3303 232 H - - - - &WAs1I 1 --SH.' 1 12 6'j'HUI Hc'it. RF/oJ12Ifl 11111,0 16011 Ii 1/ 11 H 4 0061' Hangerniate+ Pivot For Steel * Angled Applications 3.4i 38") V - - - - R1IIK1II 1 -2 1 x 1 if \57ria'il 5757 RF124 1254 .1 1,571 5 133 I,23. 'I - - - PtIII 1' 2iH'-'S 113 '.111111 0 PF3ilS'1'51 (1' 11115 (0,5 i4 1JO I 4' - - - 5373 12c, I I) - - - !Jl1P1$I 114-14X1P1 iFld,1L 157 PFM2 111250 114° 07 - - 3/51615571 41 - - - iiangermaie+ bHspenuer i-or bieei - uuai-uireciionau ga :;/l:;1:53C#j1l:lUi111,1::i1,(rrrIiI1:3:11I:::11:i:(2I:11::1,3:/;b::11::::I1:::93i::11lii3 ( 5'ilii 16 H 1 4an4aermate+ For Steel - Acoustical Ceilme Screw Eyelet PFM2251500 16 P F%1 I-- PFM2251550 - iW'- • : . YALT -p lu -p lu lu -p -p -p lu -p lu lu lu lu IQ -p • -I lu I I ho I OEWAtT 4 L lu lu II lu lu lu I • I I I -- - -p -p lu lu 7m lu lu -p lu II - - ' -------------- h II, l: Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 1/16 3/4 1 7/16 1 610 28 1/2 11/2 3/4 1 9/16 11/4 1130 55 5/8 11/2 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 13/,e 11/4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 11/4 1130 55 5/8 11/2 11/4 1 9/16 11/4 1130 55 * Max. toads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/4" Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8", 1/2 and 5/8" rod Component of State of California OSHPD Approved cLYLJUS ttsiu Material - Carbon Steel with hardened cup point set screw and Seismic Restraints System jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4 ' (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or B bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set I screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the E clamp. Open design permits inspection of thread engagement. Approvals Underwriters' Laboratories Listed in the USA (UL) and -" I Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA) Pamphlet 13 3/8 rod will support 1/2 thru 4 F pipe, 1/2 rod will support 1/2 thru 8" pipe. Included in our Seismic ' 1' Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional A load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish— Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,5 70,885 K OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 I CUSTOMER SERVICE • 800.786.5266 www.fokjo.com Fig. 200 - "Trimline" Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range - 1/2 thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2 thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2 thru 8') Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2' thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 3% 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 2/8 400 13 11/2 3/8 8mm or 10mm 37/8 2/a 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/6 41/h 600 27 3 3/8 10mm 57/8 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/6 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 6-9/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 600.786.5286 www.tolco.com Fig. 69 - Beam Clamp Retaining Strap Size Range - 3/8 thru 7/8 rod by 4 thru 16 length.* Material - Pre-Galvanized Steel Function - To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (2010) 9.3.7.1. Important Note - Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mech- anism of some kind such as a hex nut or the beveled locking slot on the TOLCO® Fig. 69R will provide a more secure reliable installation. Approvals - Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relat- ing to OSHPD proiects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Pre-Galvanized Order By - Figure number, type, length "B" and rod size being used with beam clamp Note - Minimum return on Strap: 1 Dimensions Type Rod Size A Hole Size B 1 3/8 7/16 Specify 1/2 9/16 Specify 2 5/8 11/16 Specify 3/4 13/16 Specify 3 3/8 -7/8 Specify Specify * Longer lengths are available, consult factory. Component of State of California OSHPD Approved Ui. US LISTED Seismic Restraints System OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.788.5266 S www.tolco.com Component of State of California OSHPD Approved Seismic Restraints System FIG 98 Size Range - Secures 3/8' thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 4. Fig. 98 - Rod Stiffener Fig. 98B - Rod Stiffener w/Break-off Bolt Head Size Range - Secures 3/8' thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing Approvals - Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating toOSHPDproiects. please refer to the TOLCO Seismic flLI 1II IL OYSLems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100- All Thread Rod Full Length Size Range - Secures 3/8" thru 11/2 rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F Wt./100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PFF 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Victaulic® FireLockTM Outlet-T JtauIic Style 922 10.52 1.0 PRODUCT DESCRIPTION Available Sizes 1 1/4 -2 1/2 7DN32—DN65 Threaded Outlet Sizes: 1/2 /DN15, -3/4 /DN20, and 1/DN25 NOTE IGS Grooved 1/DN25 Outlets available for this product. See oublication 10.54. Maximum Working Pressure 300 psi/2068kPa/21 Bar Application Provides a convenient method of incorporating outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products Pipe Material Carbon steel Contact Victaulic for use on additional pipe types and wall thicknesses 2.0 CERTIFICATION/LISTINGS @' [[P1 LTD NOTES See Section 7.2 REFERENCE MATERIALS for additional certification information. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. [stem No. Location Submitted By Date Spec Section Paragraph Approved Date Hir+I,r' 10.52 3355 Rev II Updated 06/2018 © 2018 Victaulic Company. All rights reserved. 1 '\Acctsulliic~ victaulic,com 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) Li Orange enamel (North America, Latin America, Asia Pacific). Li Red enamel (Europe). Li Optional: Contact Victaulic with your requirements for other coatings. Gasket': Li Grade "E" EPDM (Type A) EPDM (Violet color code) Applicable for wet and dry (oil-free air) sprinkler services only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40°F/-40°C and above. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are riot compatible. Bolts/Nuts: Li Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex flange nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex flange nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type Ill (imperial) or Type II (metric). 10.52 3355 Rev H updated 06/2018 © 2018 Victaulic company. All rights reserved. victauIiccom 2 J_i_r _________ U Style 922 victauUccom 4.0 DIMENSIONS Style 922 Size Bolt/Nut Dimensions Weight I Nominal Actual I Approximate x Branch FPT2 Run Outside Diameter Qty. Size T3 V W V Z (Each) i inches inches inches inches inches inches inches inches lb DN mm mm mm mm mm mm mm kg 14 004 0.840 .. 1.30 1 1.83 1 10 3.87 2/- 0N32 1415 474 713 77 47 25 98 05 u.S 1i50 X 1 18 183 110 387 2 1 D1420 17 28 98 65 05 1 11 2 1 S 110 39 'r5 1 ) DN25 357 55 28 . 5 0.5 1½ ½ 1.900 0.840 2 x1 1.42 1.95 1.22 4.08 2.56 1 40 DN15 483 21.3 36 50 31 104 65 0.5 3/4 1.050 1.40 1.95 1.22 4.08 2.56 1 2 h 1 DN2O 26.9 36 50 31 104 65 0.5 1 1.315 2 x 1 1.64 2.30 1.22 4.08 2.56 1 DN25 42 58 31 104 65 0.6 2 . 0,840 1 o 219 1.46 4 60 1 50 1)1 213 Ill 56 37 117 06 I 50 2 £X1 I 1 19 146 0 ",56 1 4720 1 37 11 65 06 1 1 315 100 114 1.44 4c0 2.56 2 25 2 x I 48 65 37 117 65 07 2½ 1h 2.875 0.840 2 x 1 1.91 2.44 1.71 5.40 2.56 2 0N15 73.0 21.3 49 62 43 13765 0.7 3/4 1.050 2 x 1 1.89 2.44 1.71 5.40 2.56 2 0N20 26.9 48 62 65 0.7 1 1.315 2 x 1 2.13 2.79 1.71 5.40 2.56 2 DNJ2S 54 71 43 117 65 0.7 DN65 /2 300 0,840 1 2 .4 171 . 2 715 1 13 62 43 L50 2 x 1 I 4 2,44 1.71 4420 .0.9 45 62 43 11,1 1 1 15 13 279 171 550 256 2 X1 DN2S , 51 7 43 140 65 0.8. 2 Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Refer to the specific literature for these types of special male -threaded products for guidance and possible limitations for use. Failure to verify suitability In advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. 3 \4tauIic victaulic.com 5.0 PERFORMANCE Style 922 Run Size x Outlet Size inches DN DN32 X IS 1 II1fl X [iN 50 [N 2½ 1 DN25 DNGS lent Length of 1 inch Schedule 40 Steel Pipe (per Threaded feet meters 8.5 2.6 UL 213, Section 16) (C=120)4 Grooved-' feet meters Hazen-Williams coefficient of friction is 120. 1 Firel-ock"I Innovative Groove System (IGS) outle 6.0 NOTIFICATIONS WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Dimensions Minimum Hole Diameter! Maximum Hole Diameter! Hole Saw Size Hole Saw Size inches inches mm mm All OLIIIL 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 4 JtauIic I vctauIic.com 7.1 REFERENCE MATERIALS Size Services Pressures per Regulatory Approvals and Listings6 inches psi psi psi psi psi psi 1 ¼x½ 300 300 300 T17 232 232 DN32XDN15 i 2068 2068 1 1600 1600 1¼x'/4 300 300 300 232 232 232 DN32XDN20 2068 j 2068 2068 1600 1600 i 1600 - -- _ 1 1/4 x 1 300 300 300 232 232 232 I 32 X DN25 2068 2068 2 1600 1600 0 1½x½ 300 300 300 232 232 232 DN40XDN15 2068 2068 2068 1600 1600 1600 1 2x~/4 300 300 301 232 272 DN4OXDN2( 7fl6 7068 2061 1600 ifi 100 1 1rx1 00 300, 232 2 2 DN40 X DN2 . :168 1 206 1600 18 1 10 2x12 .00 300 300 232 2 232 DN50XDN15 2068 2068 2068 1600 1817 1600 2x 1n 300 300 301 232 2 732 2061, 1600 1600 1 1 300 232 ., 232 DN5OXDN2C --------- 2068 1168 206c 1600 lii 1600 21/2x½ 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 77 300 2 232 232 L x 1 2068 300 (C 3UL) 2068 .1600 300 232 1600 232 1600 232 2068 2068 2068 1600 1600 1600 .32 DN65XDN1 - I .t,L2 100 1 232 232 DN6S X DN2O . 1600 1600 232 27 2 2 I '75X '.J,), .I 1000 11 1 1 Pressures listed in this chart are based upon standard wall pipe. Approved and Listed pressures may vary by pipe schedule. NOTE Consult regulatory agency websites for details and the most recent regulatory information. 7.2 REFERENCE MATERIALS 05.3.1:1....V....8.0110 11t1L4.I1T3S?....11.1,111337 20.01 Victstilic Terms and Conditions at Sale .1 100 Installation Instructions -022 burslalbotiun Ins Vuotiorrs it el ,)05TM Outiel- 1 p User Responsibility for Product Selection and Suitability Note Each user bears final responsibility icr making a determinationas fouls suitabrliry 01 lOis product shall Ire rearruiacturost try Vrctaulic or to Victaulic specifications. All products Victaulic products for a particular end-use application, in accordance with industry to be installed in accordance with current Victaulic irstettation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard regulaiiorrs an well as Victaulic tirrrforrrrarrce, maintenance, safety, and warning equipment wit horn, notice and without incurring obligations. instructions. Nothing in this or any other document, nor any verbal recommendation, Installation advice, or opinion from any Victaulic sIc ms pIty e shall be deerned to altcr, vary s ipe SLilu Reference. should always bc Frade io the Vict slic installalion handbook or in till rtiorr or wave any provision of Victaulic Company's standard conditions of sale, installation instructions of the product You are installing. Handbooks are included with each shipment grade, or this disclaimer, Of Victaulic products, providing complete installation and assembly data, and are available Intellectual Property Rights in POE format on WeChal. No statement contained herein concerning a possible or suggested use of any material. Warranty product, so rvice, or rtr'sin is intended, or shirirlrt he constructed, to Irarrl any In r rsi Refer to the Warranty section of the current rn Price list or contact Vir'laulir' for details under any patent or other intellectual property right of Victaulic or any of its subsidiaries Or affiliates covering such use or dsnigrr, or ass recommendation for the use of such Trademarks material, product, service, or design in the infringement at any patent or other intellectual Vicfsufic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms "Patented" or "Potent Pending" refer to design or utility patents Victai:lic Company, and/or its attliuted entities, in the U.S. and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries, 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved, victaulic.com 5 JtiuIicr