HomeMy WebLinkAbout5040 TIERRA DEL ORO ST; ; AS1401916/27/24, 3:40 PM 0 AS140191 Permit Data City of Carlsbad Sprinkler Permit 5040 TIERRA DEL Job Address: ORO ST Permit Type: SPRINK Parcel No: 2100200700 Lot #: 0 Reference No.: Permit No: AS140191 Status: ISSUED Applied 7/25/2014 Approved: 8/6/2014 Issued: 8/6/2014 PC #: Inspector: Project Title: PORTER RESIDENCE NEW SPRINKLER SYSTEM FOR RESIDENCE: EXERCISE ROOM, BEDROOM #3, AND ELEVATOR AT 1ST FLOOR (416 SF) NEW MASTER BEDROOM/BATH/CLOSET, VEIW ROOM, AND OFFICE AT 2ND FLOOR (1257 SF) TOTAL NEW LIVING SPACE: 1,673 DF EXISTING LIVING SPACE: 2,431 SF TOTAL LIVING SPACE: 4,104 SF NEW WATERPROOF BALCONY AT 2ND FLOOR (300 SF) COVERED ENTRY (105 DF) EXISTING GARAGE: 388 SF Applicant: ALPHA FIRE PROTECTION 500 HACIENDA DR #180 VISTA, CA 760-727-6993 Owner: COOK JOAN D SEPARATE PROPERTY TRUST 05-15-81 7040 AVEN IDA ENCINAS #104-369 CARLSBAD CA Fees ($) Add'I Fees ($) j Total ($) Balance ($) 470 * 0 470 0 about:blank 1/1 2. ALPHA FIRE PROTECTION RESIDENTIAL FIRE SPRINKLER SYSTEM :7/10/ JOB ADDRESS: 5040 TIERRA DEL ORo, CARLSBAD, CA. ASSESSOR'S PARCEL NUMBER: 210-020-07 OWNER'S NAME: PORTER OWNER'S ADDRESS: SAME OWNER'S PHONE NUMBER: GENERAL CONTRACTOR'S NAME: BH WORTHING CONSTRUCTION GENERAL CONTRACTOR'S ADDRESS: GENERAL CONTRACTOR'S PHONE NUMBER: SPRINKLER CONTRACTOR'S NAME: ALPHA FIRE PROTECTION SPRINKLER CONTRACTOR'S ADDRESS: 4203 GENESEE AVE #103-424 SAN DIEGO, CA 92117 SPRINKLER CONTRACTOR'S PHONE NUMBER: (760) 727-6993 CALIFORNIA STATE LICENSE #582853 EXPIRES 12-31-2015 HYDRAULIC NOTES: WATER METER SIZE: 1" (NEW) METER ELEVATION: -30 AMSL PRESSURE AT METER: 93 PSI FLOW (GPM): HOUSE SIDE OF METER: 50 GPM PAD ELEVATION: 31' PRESSURE AT PAD: 893 PSI PIPE LENGTH: METER To PAD: 15' Pipe Type/Size: PVC —1 1/4" SPRINKLER TABLE: FROM LINDA ONTIVEROS @ CARLSBAD WATER DEPT (760) 602-2750 DATE: 7-21-14 SYMB COMPANY & MODEL ORF TYPE TEMP K-FAT CANOPY QTY Tyco LF-II 1/2 SSP RR Sin#2524 165 Degree 4.9 White Concealed 29 Tyco TY-FRB Sin # 3231 1/2 SSP 200 Degree 5.6 White Recessed/none 7 Total 41 PIPE TABLE: TYPE MFG MODEL AREA OF USE CPVC TYCO BLAZEMASTER SYSTEM STEEL ALLIED SCHEDULE 40 NONE USED COPPER MULLER TYPES M & L SUPPLY PVC SPEARS SCHEDULE 40 SUPPLY NOTE: PIPE MUST BE U.L. OR F.M. LISTED FOR RESIDENTIAL FIRE SPRINKLER USE. PLANS MUST STATE: "PIPE WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS." "A COPY OF PIPE MANUFACTURER'S INSTALLATION INSTRUCTION PAMPHLET MUST BE KEPT ON-SITE." Alpha Fire- Hydraulic Calculations Contract Name: R (ZT€ Sheet / of ( Calculation for: 2.-/11/2 OW Date: Nozzle Type & Location Flow In GPM - Pipe Size Inches Fittings And Devices Pipe Fittings Total Friction Loss psi/fl Required Pressure psi Elevation Node Notes q TypecP Diameter 7( C-Factor / $Z) Ln Pt UP, 70 I 13 Ft 12.. Pf 3,77 Tot 16' Pe q Q Type Diameter C-Factor Ln Pt 20-14 7 Ft Pf Tot Pe q Q Type C/o C Diameter C-Factor / oC Ln 7 gq PtI(p,70 p Ft 11 pf 3 qq Tot 1cl Pe .-' ç Q 40 Type C,- Diameter f C-Factor / f? '2 IM Ln5 2 '-1 9 3 PtZO,? 3 4 Ft 2,2- Pf L9, 40 Tot 7 5 Pe 4,33 c q Q q D Type&Q C-Factor ico Lu 4LA.6 07 7 7 Tot 9O,5 Pt Diameter t't Ft 3 Pf C Pe,j0 q Q (.L9 Type, Diameter 4 C-Factorl o 7. Tr,, a—C (ii Ln , gj,; 73 It It 7 Pi Tot (7 Pe 3 L) q Q q 0 Type Al C U Diameter it1 C-Factor I D c, Ln ; 0 Pt 571 ( (p A/ $6/' i-PJ Ft i q Z. ,4 c1 To 2. 7, Pe Q LI Type CC V Diameter? kj C-Factor 15D ic Ln (q / Tot e? Pt L (ii. 7 34) 611Z Ft Pf - Pe ..-' q Q 5 Type P V c,- Diameter)1 CFactorO Ln / /oqc) Pt ( Z 3e ? Ft Pf Tot /5 Pe 3 q Q Type Diamete11 / C-Factor Ln Pt '°' '' /11 t o Ft Pf 4,5. Tot - Pe ..TIO _ q Q 1.) Type it j Diameter C-Factor ) Ln(2. qqqq Pt7(O,, 10 3 0 Ft Pf qq Tot I ' Pe 30 q Q Type Diameter C-Factor Ln Ptgo.g It , 7 Ft Pf Tot Pc Fire Protection Products Worldwide l Contacts www.tyco-flre.com RAPID RESPONSE Series LFII Residential 49 K-factor Concealed Pendent Sprinklers, Flat Plate Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Se- ries LFII Residential 4.9 K-factor Con- cealed Pendent Sprinklers (TY3596) are decorative, fast response, fus- ible solder sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII Residential Concealed Pendent Sprinklers (TY3596) provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment provides a measure of flexibility when cutting fixed sprinkler drops. The Series LFlI Residential Concealed Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprin- kler systems for residential occu- pancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 The Series LFII Residential Concealed Pendent Sprinklers (TY3596) has been designed with heat sensitivity and wa- ter distribution characteristics proven to help in the control of residential fires and to improve the chance for occu- pants to escape or be evacuated. The Series LFII Residential Concealed Pendent Sprinklers (TY3596) are shipped with a Disposable Protective Cap. The Protective Cap is temporar- ily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Protective Cap is removed and the Cover Plate Assembly installed. Dry Pipe System Application The Series LFII Residential Concealed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Concealed Pendent Sprinklers (TY3596) need not be increased over the number of de- sign sprinklers (hydraulic design area) as specified for wet pipe sprinkler sys- tems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFll Residen- tial Concealed Pendent Sprinklers of- fer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hy- draulic design area) for systems de- signed to NFPA 13,13D, or 13R. FEBRUARY 2014 LNO _TIC E The Series LFII Residential Con- cealed Pendent Sprinklers (TY3596) described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the National Fire Pro- faction Association, in addition to the standards of any authorities having ju- risdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number 1Y3596 TFP442 SPRINKLER- SUPPORT CliP ASSEMBI /OPERATE j SPRINKLE COVER PLATE RETAJNEI 7/8" (22,2 1-1/8" (28,6 ii DISPOSABLE DEFLECTOR IN TFP442 Page 2 of 6 BODY (1/2" NPT) - CAP SADDLE - SUPPORT CUP WITH - ROLL FORMED THREADS GUIDE PIN 7 GUIDE PIN HOUSING DEFLECTOR - WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 18 SPRINKLER WRENCH SEALING ASSEMBLY SPRINKLER WRENCHING AREA COMPRESSION SCREW LEVER SOLDER LINK H H ELEMENT II I DEFLECTOR J - L (OPERATED POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING RETAINER WITH THREAD - DIMPLES EJECTION SPRING SOLDER -' COVER PLATE/RETAINER '-.. COVER TAB ASSEMBLY PLATE FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TV3596) 2-1/2° DIA. (63,5 mm) 1/2 (12,7 mm) FACE OF 1/2° THREADED SPRINKLER NPT ADJUSTMENT FITTING 1-7/8±1/4 (47,6 mm 1/8 GAP j *6,4 mm) mm) I Ea COVER- SPRINKLER- j MOUNTING RETAINER SUPPORT CUP 3/16" SURFACE ASSEMBLY ASSEMBLY (4,8 mm) 3-3/16" DIA (81,0 mm) ' TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR TFP442 Page 3 of 6 Technical Data Approvals UL and C-UL Listed. NYC Approved under MEA 44-03-E-2NSF. Certified to NSF/ANSI 61. The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers are only listed with the Se- ties LFII Concealed Cover Plates hav- ing a factory-applied finish. These Cover Plates and their part numbers can be found in the Ordering Procedure section at the end of this data sheet. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 4.9 GPM/psi112 (70,6 LPM/bar112) Temperature Rating 160°F (71°C) Sprinkler with 139°F (59°C) Cover Plate Vertical Adjustment 1/2 inch (12,7 mm) Finishes Refer to Ordering Procedure section Physical Characteristics Body ..............Brass Cap..............................Bronze Saddle ............................Brass Sealing Assembly ................Beryllium Nickel WI TEFLON Soldered Link Halves ................. Nickel Lover ............................. Bronze Compression Screw .................Brass Deflector .................. Copper or Brass Guide Pin Housing.......Bronze Guide Pins .........Stainless Steel or Bronze Support Cup ........................Steel Cover Plate .......................Copper Retainer ...........................Brass Cover Plate Ejection Spring.....Stainless Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Support Cup at three points, falls away to expose the Sprin- kler Assembly. At this point the De- flector supported by the Arms drops down to its operated position. The fus- ible link of the Sprinkler Assembly is comprised of two link halves that are soldered together with a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprin- kler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFIl Residential Concealed Pendent Sprinklers (TY3596) are UL and C-UL Listed for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cri- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturer's recommendations that may be acceptable to the authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet 1FP485 about the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth fiat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 130 and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Ta- bles A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum re- quired discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A and B as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ ft2 over the "design area" comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of "design sprinklers" specified in NFPA 13 for wet pipe sys- tems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residen- tial Concealed Pendent Sprinklers (TY3596) in dry pipe sprinkler systems, the time for water delivery must not ex- ceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 130, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described with- in the Technical Data Sheet TFP490. Operational Sensitivity The sprinklers are to be installed rela- tive to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot ex- ceed the length of the coverage area (Ref. Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). The Series LFII must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Sup- port Cup could delay sprinkler opera- tion in a fire situation. TFP442 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure °' Maximum Coverage Maximum Spacing Ordinary Temp. Rating Minimum Area Ft. x Ft. Ft. 160°F (71°C) __________ Deflector to installation Spacing flow Pressure (m x m) (iii) Ceiling Type Ft. GPM PSI (m) (L/min) (bar) 12x12 12 13 TO Smooth (3,7 X 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14x14 14 13 7.0 inches (4,3x4,3) (4,3) (49,2) (0,48) Beamed Ceilings per NFPA 130 or Concealed 13R, S (2,4) 16 x 16 (4,9 x 4,9) 16 (4,9) 13 (49,2) 7.0 (0,48) or 13. Installed in 18x18 18 17 12.0 beam (5,5x5,5) (5,5) (64,3) (0,83) 7/8to1-1/8 inches below bottom of 20 x 20 20 20 16.7 (6,1 x 6,1) (6,1) (75,7) (1,15) beam For coverage area dimensions less than or between those Indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor.Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/tt2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT-PLATE CONCEALED PENDENT SPRINKLER (TV3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure 01, °' Maximum Coverage Maximum Spacing Ordinary Temp. Rating Minimum Area'1 Ft. x Ft. Ft 160°F (71°C) Deflector to Installation Spacing Flow Pressure (m x m) (m) Ceiling Type Ft. GPM PSI (m) (L/min) (bar) 12x12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14 x 14 14 14 8.2 inches (4,3x4,3) (4,3) (53,0) (0,57) Beamed Ceilings per NFPA 130 or Concealed a (2,4) 16 x 16 (4,9x4,9) 16 (4,9) 15 (56,8) 9.4 (0,65) 13R, or 13. installed in 18x18 18 18 13.5 beam (5,5x5,5) (5,5) (68,1) (0,93) 7/8to1-1/8 inches below bottom of 20 x 20 20 21 18.4 (6,1 x 6,1) (6,1) (79,5) (1,27) beam For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow In GPM (2M) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow In accordance with the criteria in this table must be used. TABLES DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT-PLATE CONCEALED PENDENT (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA Fire Protection Products Worldwide Contacts I www.tyco-flre.com Series 7Y-FRB - 28,4.21 56, and 80 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pen- dent, and Recessed Pendent Sprin- klers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY- FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. NOTICE The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. OCTOBER 2013 Sprinkler Identification Number (SIN) TY1131: Upright 2.81K, 1/2" NPT 1Y1231: Pendent 2.81K, 1/2" NPT 1Y2131: Upright 4.2K, 1/2- NPT TY2231: Pendent 4.2K, 112 NPT TY3131: Upright 5.6K, 1/2"NPT TY3231: Pendent 5.61K, 1/2" NPT TY4131: Upright 8.0K, 3/4" NPT 1Y4231: Pendent 8.0K, 3/4" NPT TY4831: Upright 8.01K, 1/2" NPT 1Y4931: Pendent 8.01K, 1/2- NPT TFPI7I STYLE 10 or 20 -*--- 2-7/8° (73,0 mm) DEA. -.. RECESSED ESCUTCHEON RECESSED PENDENT CROSS SECTION TFPI7I Page 2 of 10 3 - Sealing 5 - Compression Assembly Screw 4-Bulb 6Deflector* * Temperature rating -- Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector. special request. PLATE SEATING SURFACE 7/16" (11,1 mm) NOMINAL MAKE-IN W/2X' I 2-3/16" ** mm) T WREN (55,6 FLATS UPRIGHT 2 mm) rI 1/4" STYLE 10 or 20 RECESSED PENDENT ESCUTCHEON 1- 2-7/8" (73,0 mm) DlA. RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT ((1 131) AND PENDENT (7Y1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE * Temperature rating -- Pipe thread connections per Is indicated on ISO 7-1 can be provided on Deflector. special request. 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* OMINAL (556 WN I WRENCH FLATS UPRIGHT PENDENT FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT ('rf2131) AND PENDENT (r?'2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I SIGNAL*** WHITE LEAD COATED 5.6 1/2" NPT PENDENT TY3231) and UPRIGHT (TY3131) 135°F (57°C) Orange 1, 2, 3, 4, 5, 6, 7 Blue 1, 2, 3, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY3231)* Figure 10 135°F (57°C) Orange 1, 2,4, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (83°C) Green 286-F (141-C) RECESSED PENDENT (TY3231)** Figure 11 135°F (57°C) Orange 1, 2, 3,4, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) 8.0 3/4" NPT PENDENT (1Y4231) and UPRIGHT (TY4131) 135°F (57°C) Orange 1, 2, 3, 4, 5, 6, 7 Blue 1, 2, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286-F (141-C) RECESSED PENDENT (1Y4231)* Figure 12 135°F (57°C) Orange 1, 2, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY4231)** Figure 13 135°F (57°C) Orange 1, 2, 3, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (1Y4831) 135°F (57°C) Orange 1, 2, 4,5, 6 Blue 1,2, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 288°F (141°C) NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k104) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VCIS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a106) as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10 (1/2" NP1) or Style 40(3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A. Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS f)