Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6191 EL CAMINO REAL; ; FA070066
7/10/24,1:32 PM FA070066 Permit Data City of Carlsbad Fire Alarm Permit 6191 ELCAMINO Job Address: REAL Permit Type: FALARM Parcel No: 2131002300 Lot #: 0 Permit No: FA070066 Status: ISSUED Applied 8/27/2007 Approved: 9/18/2007 Reference No.: Issued: 9/18/2007 PC #: Inspector: Project Title: VIASAT, BLDG 42 FIRE ALARM INSPECTIONS @ $62/EA Applicant: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO CA 760-747-3050 Owner: LEVINE INVESTMENTS LIMITED PARTNERSHIP 1702 E HIGHLAND AVE #310 PHOENIX AZ Fees ':7 Total ($) Balance ($) fAldhIFees ($) about:blank 1/1 FIRE ALARM ALARM - SECURITY - LOW VOLTAGE SYSTEMS APPROVUBMITTED CARLSBAD Ft E DEAfMENT VIASAT BLDG. #4 6191 EL CAM[NO REAL CARLSBAD, CA FIRE ALARM SYSTEM These plans have been reviewed for apparent compliance with the current applicable codes and standards in force in the jurisdiction. The owner or contractor may utilize this review in support of an application for it huikliitg Permit with the express understanding that this review in no way relieves the owner or contractor or their protessional engineer or architect Or stile responsibility for full compliance with said codes and stan tlt dards. including the building code or for any responsihv fir deficiencies. errors. omissions or negligence in these plans whether or not noted in this review. Dale: q/y/ or Reviewer: 14/V (J RECOMMENI) APPROVAL RECOMMEND APPROVAL. AS NOTED j VIASAT BLDG. #4 CARLSBAD, CA BILL OF MATERIALS NOTIFIER FMM-101 MONITOR MODULE CSFM# 7300-0028:202 August 23, 2004 DN-6720 H-220 FMM-1, FMM-101, FZM-1, FDM-1 NOTIFIER® Monitor Modules with FlashScan® Section: Intelligent/Addressable Devices GENERAL Four different monitor modules are available for NOTIFIER in- telligent controls to suit a variety of applications. Monitor mod- ules are used to supervise a circuit of dry-contact input de- vices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1). FMM-1 - is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input de- vices. FMM-101 - is a miniature monitor module (a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D) used to supervise a Class B (Style B) circuit. Its compact design allows the FMM-101 to often be mounted in a single-gang box behind the device it's monitoring. FZM-1 - is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. FDM-1 - is a standard-sized dual monitor module used to monitor and supervise two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a new communi- cation protocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between ana- log intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FlashScan® is a registered trademark of NOTIFIER.. FMM-1 MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan® sys- tems, 01 - 99 on CLIP systems. LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1 Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or tour-wire fault-tolerant Initiating Device Circuit (lDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1 can be used to replace MMX-1 mod- ules in existing systems. LISTED CS669 APPROVED S635 U.S. Coast Guard 161.002/2313 (AFP-200; FMM-1/-101, FZM-l) 161.002/42/1 California (NFS-640: FMM-1/-101) State Fire Marshal 7300-0028:202 I _ 9 6789 detail of FDM-1 5 ,O 4 If 11 311 12 ii .113 - note "ones" TENS 2 addresses are 0, 2, 4, 6, 8 only 6 8 31 ONES ( LOOP ADDRESS FMM-1 Applications - Use to monitor a zone of four- wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact alarm activation devices, May also be used to monitor normally open supervisory devices with special supervisory indica- tion at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for su- pervision of the Style D circuit. Maximum IDC loop length is 2.500 ft./762 m (20 ohms maximum). 93/60141 (E3) (FMM-1/-101, FZM-1) 94/60004/E2 (AFP200.- except FDM-1) 02/60007 (NFS-640: FDM-1) MEA 143-01-F (FDM-1) 317-01-E (FMM-1I- 101) 345-02-E (FMM-1/-101) 457-99-E (FZM-1, FMM-1I-101) 447-99-F FMM-1 and FZM-1 NOTIFIER® is a Honeywell company product information up-to-date and accurate We cannot cover all specific applications ISO 9001 This document is not intended to be used for installation purposes. We try to keep our or anticipate all requirements, All specifications are subject to change without notice. ill =4 - _id I i i For more information, contact NOTIFIER. Phone: 12031 4847161 FAX: (203) 484-7118 ENGlNEIRlNG 9 MANUFACTURING NOT I F I E R 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS DN6720 . 08/23/04 - Page lof 6 FMM-1 Operation -Each FMM-1 uses one of 159 avail- able module addresses on an SLC loop. It responds to regu- lar polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communica- tion with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). FMM-1 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 375 pA (LED flashing). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4' (10.16 cm) wide x 1.25 (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125' (5.398 cm) deep box. FMM-101 MINI MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the panel. Powered directly by two-wire FACP. No additional power required. High noise (EMF/RFl) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScant sys- tems, 01— 99 on CLIP systems. ADDRESS 121 L OP Ilk TENS ONES H-. 0 Lu 0 C) d The FMM-101 Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101 is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101 can be used to replace MMX-101 module in existing systems. FMM-101 Applications - Use to monitor a single de- vice or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry- contact devices; May also be used to monitor normally-oper supervisory devices with special supervisory indication at the control panel. Monitored circuit/device is wired as an NFPP Style B (Class B) Initiating Device Circuit. A 47 ohm End-of- Line Resistor (provided) terminates the circuit. FM M-1 01 Operation - Each FMM-101 uses one of 15 available module addresses on an SLC loop. It responds tc -egular polls from the control panel and reports its type and he status (open/normal/short) of its Initiating Device Circuit (IDC). FMM.101 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3' (3.302 cm) high x 2.75' (6.985 cm) wide x 0.5' (1.270 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM-1 INTERFACE MODULE Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan® sys- tems, 01 —99 on CLIP systems. LED flashes during normal operation (this is a program- mable option). LED latches steady to indicate alarm on command from control panel. The FZM-1 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional de- tectors back to the control panel. All two-wire detectors be- ing monitored must be UL compatible with the module. The FZM-1 has a panel-controlled LED indicator and can be used to replace MMX-2 modules in existing systems. FZNI-1 Applications - Use the FZM-1 to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Ini- tiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (pro- vided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. FZM-1 Operation - Each FZM-1 uses one of 159 avail- able module addresses on an SLC loop. It responds to regu- lar polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communica- tion with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). FZM-1 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 255 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 Vevs maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4 5" (11.43 cm) high x 4 (10.16 cm) wide 1.25' (3.175 cm) deep. Mounts to a 4' (10.16 cm) square 2.125' (5:398 cm) deep box. Page 2 of 6 - DN-6720 - 08/23/04 FDM-1 DUAL MONITOR MODULE The FDM-1 Dual Monitor Module is intended for use in in- telligent, two-wire systems. It provides two independent two- wire initiating device circuits (IDCs) at two separate, consecu- tive addresses. it is capable of monitoring normally open contact fire alarm and supervisory devices or either normally open or normally closed security devices. The module has a single panel-controlled LED NOTE: The FDM-1 provides two Class B (Style Y) (DC circuits ONLY. Class A (Style Z) (DC circuits are NOT supported in any application. FDM-1 Specifications Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 5.7 mA (LED on). Maximum operating current: 750 pA (LED flashing). EOL resistance: 47K ohms. Maximum IDC wiring resistance: 1,500 ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4' (10.16 cm) wide x 2.125° (5.398 cm) deep. FDM-1 Automatic Addressing —The FDM-1 auto- matically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1 is set to address '56", then it will automatically assign itself to ad- dresses "56" and "57'. NOTE: "ones" addresses on the FDM-1 are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first ad- dress, and terminals 8 and 9 use the second address. J -CAUTION! V Avoid duplicating addresses on the system. INSTALLATION FMM-1, FDM-1, and FZM-1 modules mount directly to a stan- dard 4" (10.16 cm) square, 2.125" (5,398 cm) deep, electrical box. They may also be mounted to the SMBSOO surface-mount box. Mounting hardware and installation instructions are pro- vided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. PRODUCT LINE INFORMATION FMM-1 Monitor module. FMM-101 Monitor module, miniature. FZM-1 Monitor module, two-wire detectors FDM-1 Monitor module, dual, two independent Class B circuits. SMB500 Optional surface-mount backbox. ARCHITECTS'/ENGINEERS' SPECIFICATIONS Specifications of these and all NOTIFIER products are avail- able from NOTIFIER. © 00 CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING Face Plate for FMM-1, FZM-1, and FDM-1 MOUNTING DIAGRAMS - -. for siandard-sized 1- -Ji:2j modules 1(1 J l / fl I ifl - ,/ )) - DN-6720 08/23/04 - Page 3o(6 WIRING DIAGRAMS The following wiring diagrams are included: FDM-1 typical dual two-wire Style B initiating device circuit configuration. FMM-101, typical two-wire Style B initiating device circuit configuration. FMM-1 typical two-wire initiating circuit configuration, NFPA Style B. FMM-1 typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. FMM-1, typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). FZM-1, interface two-wire conventional detectors, NFPA Style B. FZM-1, interface two-wire conventional detectors, NFPA Style D. FRM-1 relay control module used to disconnect a power supply. Fig. I FDM-1: Typical dual two-wire Style B initiating device circuit configuration. Two Initiating Device Circuits ,WWI (L & H) TO Next each power-limited to Device - FROM Panel 230 pA max. 12 VDC max. MONITOR (+) or Previous Device 47K EOL MODULE Resistor Communication Line ELR-47K 32 VDC maximum. El z Twisted-pair is recommended. 47K EOL All wiring shown is supervised Resistor L ONES and power limited. ELR-47K LOOP ADDRESS Connect modules to listed compatible NOTIFIER control panels only. ANY NUMBER of UL Listed contact closure devices may be used. 6822vqrl.wmf DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. Install contact closure devices per manufacturers installation instructions. (+) (1 TO /1 . 4 //-NEXT .1 1 DEVICE BLACK RED UL LISTED Compatible (-) (+) FMM-101 Control 5110 5-'- 8 9 Panel 3 (1' '12 /1 1 1514 (-) VICLETI-1 -4 YELLOW Fig. 2 Ffv1M-101: Typical two-wire Style B initiating device circuit configuration. 47K EOL INCLUDED M Page 4 of 6 — ON-6720 0e/23/04 Connect modules to listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Install contact closure devices per manufacturers installation instructions. Any number of UL-listed contact closure devices may be used. DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. V Fig. 3 FMM-1: Typical two-wire initiating device circuit configuration, NFPA Style B. TO Next Device MONITOR Initiating Device Circuit (ID C) 0 MODULE NFPA Style B, power limited: Communication Line 230 pA max. 12 VDC max.011 4 , - , . 8 is 47K EOL Resistor 6 3 ELR-47K 5 LOOP ONES ADDRESS which supporunis feature) ° FUTURE FEATURE C) 672Owr2.wnf 'V Fig. 4 FMM-1: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. 32 VDC maximum. Twisted-pair is — recommended. Communication Loss (optional connection for panels —) FROM Panel or Previous —4 Device EOL Resistor is internal at terminals 8 & 9 FROM Panel or Previous Device tion Line mum. Is d. anels re) 'V Fig. 5 FMM-1: Typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). TO Next (—) FROM Panel Initiating Device Circuit (IDC) Device or Previous NFPA Style B power limited MONITOR '—1 Device 230 pA max. @ 12 VDC max Communication Line 14K Series Resistor . .-. . ) 32 VOC maximum. Twisted-pair is 10 8 i(]). 1 7 recommended Resistor ss oUrs s connection0 for panels which support this feature) FUTURE FEATURE DN-6720 . 08/23/04 — Page 5 of 6 Connect modules to listed compatible control panels only. Terminal wiring must be power limited. DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. DO NOT LOOP wire under terminals. Break wire run to provide supervision of connections. Detectors must be UL listed compatible with module. Install detectors per manufacturers installation instructions. Power to the interface module must be externally switched to reset the detectors. An FRM-1 relay Control module can be used to switch power from a standard power supply; see Fig. 7 below. 'V Fig. 6 FZM-1: Interface two-wire conventional detectors, NFPA Style B. 3.9K EOL Resistor (included) A2143-1O TO Next Device INTERFACE MODULE 0 .37 ENs 2 6 ( 3 15 4 W ONES csco9 6120w45wnI r FROM Pane! or Previous Q Device Communication Line 1) 32 VOC maximum. Twisted-pair is recommended. Listed Battery Backup 4 switched DC I power supply. — Optional Branch Circuit TO Next Interface Module Module supervises supply voltage and detector loop. V Fig. 7 FZM-1: Interface two-wire conventional detectors, NFPA Style D. 3.9K EOL Resistor uinr/,icor1) rar1i arr1 TO N?xt Device flJ INTERFACE 7 n— MODULE o .±L4 FROM Panel or Previous Device Communication Line 32 VDC maximum. Twisted-pair is recommended. terminals 8 6 30 Listed ttery e:d DC . Backup ------ LOOP ONES . I i S, ____ power — Optional Branch Circuit TO Next Interface Module Module supervises supply voltage and detector loop. 'V Fig. 8 FRM-1: Relay control module used to disconnect a power supply. TO Next -4 Device FROM Panel +) or Previous Device DC POWER SUPPLY Listed forFire (—) Protection with Battery Backup (—) I (+) 4 CONTROL MODULE 0 9 —j 1, 7H 21 6 31 5HH4l OP ADOR cs 00 Communication Line 32 VDC maximum. Twisted-pair is (+) recommended. 672Ow7 ;v( Page 6 of 6 — DN-6720 08/23/04 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:202 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, *FTM..1 monitor modules and Models FCM-1, FRM-1 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. *Model FTM-1 is intended to be used with Notifier Models NFS-640 (CSFM Listing Nos. 7165-0028:214 and 7170-0028:216), NFS-3030, NFS2-3030 (CSFM Listing Nos. 7165-0028:224 and 7170-0028:223) Fire Alarm Control Units. Rev. 07-12-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager