HomeMy WebLinkAbout6191 EL CAMINO REAL; ; AS1200207/10/24,2:51 PM AS 120020 Permit Data City of Carlsbad Sprinkler Permit 6191 ELCAMINO Job Address: REAL Permit Type: SPRINK Parcel No: 2131002300 Lot #: 0 Reference No.: Permit No: AS120020 Status: PENDING Applied 2/14/2012 Approved: Issued: PC #: Inspector: Project Title: VIASAT BLDG #4 LAB REMODEL T.I. Applicant: Owner: SCHMIDT FIRE PROTECTION CO INC LEVINE INVESTMENTS LIMITED PARTNERSHIP 4760 MURPHY CANYON RD SAN DIEGO, CA 92123 858-279-6122 1702 E HIGHLAND AVE #310 PHOENIX AZ Fees ($) Add'l Fees ($) Total ($) Balance ($) 262 0 262 0 about:blank 1/1 Vertical Sidewall Conventional Model Fl FR56 Series Quick Response Standard Spray m Upright Pendent Horizontal Sidewall Recessed Pendent/Fl/F2 AS 12- W 2—Qulletin 014 Rev. F Reliable Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS SchadenverhUtung GmbH UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56 Series Sprinklers are quick re- sponse sprinklers which combine the durability of a stan- dard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1FR56 Series Recessed automatic sprin- klers utilize a 3.0 mm frangible glass bulb. These sprin- klers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR56 Series sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Hecesseci Horizontal Sidewall Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflec- tor style and sprinkler type are in accordance with the lat- est published standards of the National Fire Protection As- sociation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. E33 Recessed Pendent/FP The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 s— 2 5/8" 0/A. [66.7mm] HOLE IN CEILING 2 5/76" 014. [58.7mm] - CUP C " X 7/2" REDUCER I I I I I / CEILING FACE OF PITYiNG TO FACE OF CEILING DIMENSION(f) ADJUSTMENT' O?4F002 (I) REFER TO F? ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS, 2 27/32" 014. 0I4FGOI (72.2mm] (I) REFER TO TI & F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. 2 1/4" HOLE 014 (57.2mm] ' 7 75/76" 074 [ [49.2mm] L---s-.c E 1 TURN COLLAR LINIIL PONT AGAINST SPRINKLER WRENCH BOSS-- ADJUSTMENT flWWB 1" 5 7/2" REDUCER FACE OF FITTING TO CEILING DIMENSION I/B" _j [3.2-j Model F1FR56 Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model 0 Sprinkler Wrench Installation Data: Nominal Orifice Thread Nominal K Factor Size US Metric Sprinkler Height Approval Organization Sprinkler Identification Number (SIN) Upright Pendent Standard-Upright (SSU) and pendent Deflectors Marked to Indicate Position 1//'15mm ½" NPT(R1/s) 5.6 T 80 1 2.25" (57mm) 1,2,3,4 RA 1425(1I 1 RAi4142 Conventional-Install in Upright or Pendent Position 15mm 1 ½" NPT(R½) 5.6 80 57mm 3,4 RA1475 cULus listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. S.' Upright Pendent Conventional Model Fl FR56 Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread K Factor J Sprinkler Sprinkler Identification Number Orifice ------------ Size US Metric j Height (SIN) ½" (15mm) ½" NPT(R½) 5.6 80 2.25" (57mm) RA1414 Refer to escutcheon data table for approvals and dimensions. Model F1FR56/F1 or F2 Model F1FR56/FP 2. Horizontal Sidewall Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler US I Metric Orifice Thread Size Height Organizations Identification Numbers (SIN) 1/2"(15mm) ½" NPT(R1/2) 5.6 8.0 2.25(57mm) 123,4 RA1485 15mm ½" NFT (R1/2) 5.6 8.0 2.25" (57mm) 40 LPC Approval is for pendent position only. Sprinkler Type Deflector to Ceiling Distance (Min. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4" (102mm) - 12' (305mm) Vertical Sidewall Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations _________________ Sprinkler Nominal Orifice Thread Size Height and Type of Approval Identification Ordinary Numbers (SIN) US Metric Light Hazard Hazard ½"(lSmm) 1 ½" NFl (R1/2) 5.6 80 2.63" (67mm) 1,2 1 RA1435 (i) FACE OF FITTING DIMENSION 1 1/4" /1/N. [31.8mm] 2 1/4" HOLE 0/A. /8" 4-12" TO FACE OFCEILING [5 7.2mm] .2mm] [1016mm3048mm] CEILING TO 1"X 1/2" REDUCER - DEFLECTOR 227/I2"D/A. 1 15/6"DIA.il [49.2m [72.2mm TURN COLR TIGHT AGAINST SPRINKLER WRENCH BOSS. (1) A DJUSTMENT o IJFGO3A REFER TO ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. FM APPROVED FOR 4" - 6" [ID 1.6MM - 152.4MM] CEILING TO DEFLECTOR. Note: For Recessed HSW Sprinklers use installation wrench GFR2. 3. Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model AOl Sprinkler Wrench Technical Data: Nominal "K" Factor Thread Temp. Rating Max. Bulb Sprinkler Sprinkler Cover • Orifice US Metric • Size Model Ambient Color Approvals Identification Temp Number(SIN) ½" (15mm) 5.6 80 ½" NPT F1FR 135°F/57°C 135°F157°C 100°F/38°C Orange 1,2 RA1414 ½" (15mm) i 5.6 80 ½" NPT F1FR 155°F168°C 135°F/57°C 100°F/38°C Red 1, 2,40) RA1414 ½' (15mm) 5.6 80 ½' NPT F1FR 175°F/79°C 165°F/74°C 100°F/38°C Yellow 1,2 RA1414 1/2" (15mm) 5.6 80 ½" NPT F1FR 200°F/93°C 165°F/741C 100°F/380C Green 1,2 RA1414' For VdS only = 155"F/68°C Norbuib and 1/2" [12,7mm] adjustment. 1" x 7/2" REDUCING TEE OR ELBOW 2 5/8" 0/A, 2 5/16 0/A - -' -I HOLE IN CEILING CUP 03666 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING / 'SD T; T7'>7'7 DIMENSION CEILING —" - , 112 " MAX. COVER ADJUSTMENT H" 15/16 COVER PLATE ASSEMBLY 3 5/16 0/A. SPRINKLER 1/2" ADJUSTMENT o,,;co, Figure 1 1" x 1/2" REDUCING TEE OR ELBOW 2 5/16" 0/A - CUP --.,. CEILING 5/16" MAX COVER ADJUSTMENT COVER PLATE— ASSEMBLY SPRINKLER r'-t 2 5/8" 0/A. -I HOLE IN CEILING 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 3/4" — 3 5/16" 0/A. 5/16" ADJUSTMENT 017-2 Figure 2 Installation Aid A protective cap is included for use during installation, Important: The F1FR56 Sprinkler with Model COP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed, The Model F1FR56 Recessed Quick Response Sprin- klers are to be installed as shown. The Model Fl or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56 Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model Fl FR56 Sprinklers, use the Mod- el D Sprinkler Wrench. Use the Model GFR2 Wrench for installing F1FR56 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½" NPT (R1I2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprin- klers. The Model F1FR56/ COP Concealed Sprinkler uses the ½" orifice, ½" NPT (R1/2), 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C) Model F1FR56 Pendent *DuPont Registered Trade Mark Sprinkler with a threaded Model COP cup which is fac- tory attached to the sprinkler. The assembly is complet- ed by the installation of the attractive, low profile, 135°F (57°C) or 165°F (74°C) rated Model COP push on cover plate assembly. The cover plate and sprinkler cup as- semblies are joined using a cover plate skirt with flexible tabs for threaded engagement. A choice of two cover plate assemblies provide either ½" (13mm) or /i€" (8mm) of cover adjustment. Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2 /8" (67mm) diameter hole is cut in the ceil- ing, the sprinkler is easily installed with the Model RO1 Wrench. A Teflon* based thread sealant should be applied to the sprinkler threads only. The Model AOl Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER, The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other con- cealed cover plate/cup assembly with the Model Fl FR56 Pendent Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color 0 OF Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High 141 286 225°F (107°C) Blue Not available for recessed sprinklers. Escutcheon Data (1) Escutcheon "A" FaceofFrthngto Model Approvals Adjustment Dimension Ceiling or Wall Dimension Fl 1,3,4 Max Recess 11/2" (38 lrrni) 3/16" - Min Recess 3/4 (19.1mm) (5mm - 24rrn) F2 1,2,3,4 Max Recess 1 'W(38, lrrrn) ________ Min Recess 1" (25rrrn) I (5rm -l7nm) FP Push-on/ 1,4 Max Recessed 7/s" (llnTn) 1 1Y2" (38.lrrni) Thread-off Mm Recessed 15/ (24n'rn) 1" (25.4mm) 1) SIN: RA1435 - cULus and FM permits use with Fl or F2 escutcheons for light hazard only. Maintenance The Models FlFR56 and F1FR56 Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler Escutcheon I Cover plate Bronze Brass Chrome Plated Chrome Chrome White Polyester Plated White Coated (4,5) White Painted Speci I Application Finishes Sprinkler Escutcheon Cover plate Bright Brass (3) Bright Brass Bright Brass Black Plated Black Plated Satin Black Paint (2) Black Paint Off White Off White (2) Off White Black Paint Satin Chrome Satin Chrome Black Plated Other finishes and colors are available on special order. Consult the factory for details. (2) cULus Listed only. 200°F (93°C) maximum. (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1425 (Upright) and RA1414 (Pendent) in standard black or white. (il) FM Approvals finish as "Polyester coated" applies to SIN Number RA 1414 (Pendent) in standard black or white. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model F1FR56 Recessed sprinklers are ordered, the sprin- klers and escutcheons are packaged separately. 5. 1111111111ft ReliableFor Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gaugesldentification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address - ® Recycled Paper Revision lines indicate updated or new data. 0G. Printed in USA 02/11 P/N 9999970300