Loading...
HomeMy WebLinkAbout6191 EL CAMINO REAL; ; FA1500597/10/24, 2:50 PM FA150059 Permit Data City of Carlsbad Fire Alarm Permit 6191 ELCAMINO Job Address: REAL Permit Type: FALARM Parcel No: 2131002300 Lot #: 0 Permit No: FA150059 Status: ISSUED Applied 9/8/2015 Approved: 9/9/2015 Reference No.: Issued: 9/9/2015 PC #: Inspector: Project Title: VIA SAT BLDG 4 REMOVE AND RELOCATED EXISTING DEVICES CONSISTING OF THE EQUIPMENT SHOWN IN THE DEVICE LEGEND, TO ACCOMMODATE NEW TI. Applicant: JJJ ENTERPRISES 533 5 VINEWOOD ST ESCONDIDO CA 760-747-3050 Owner: LEVINE INVESTMENTS LIMITED PARTNERSHIP 1702 E HIGHLAND AVE #310 PHOENIX AZ Fees ($) Add'I Fees ($) Total ($) Balance ($) 290 0 290 0 about:blank 1/1 FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS ViaSat Bldg 4 Tenant Improvement 6191 El Camino Real Carlsbad, CA 92011 FIRE ALARM SYSTEM MATERIAL DATA SHEETS FAIS0059 FIRE ALARM SYSTEM BILL OF MATERIALS WHEELOCK RSS-24MCC MULTICAIWELA CEILING STROBES CSFM# 7125-0785:0141 WHEELOCK AS-24MCC MULTICAIWELA CEILING HORN /STROBES CSFM# 7125-0785:0131 Series RSS and RSSP Strobes and Strobe Plates Series RSS Series RSS Series RSSWP t. Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi-candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 1 5/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1 00m European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. D OU L M EA APPROVED S5391 151-92-E 7125-0785:141 Features Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADNNFPNUFC/ANSI compliant. Meets OSHA 29 Part 1910.165 Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd. (Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage Synchronize using the Wheelock sync modules or panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire For Weatherproof Series RSS See Datatsheet S9004 SERIES RSSIRSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 Sync Strobe NAC Cir.Z:, RSSRSS F r DSM #2 A sYflC ; Strobe NAC Cir.I C DSM #3 P RSS nRS S' Strobe NAC Cir. I DSM Interconnecting wiring shown. Maximum of twenty (20) NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range. Note that NFPA-72 specifies a flash rate of I to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. 'Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSS/RSSP - Wall Mount I Ceiling Mount RSS/RSSP 241575W 24MCW 24MCWH 24MCC I 24MCCH 24VDC ___________ I I Models I I I I I I I I 1575cd l5cd 30cd 75Cd ll0cd I 135cd l85Cd I l5cd 30Cd 75cd 95cd I 115Cd I 177cd UL max* 0.090 0.060 10.092 10.165 10.220 10.300 10.420 10.065 10.105 10.189 10.2491 0.300 I 0.420 RSS/RSSP RSS/RSSP Wall Mount 4VDC * RMS current ratings are per UL average RMS method. UL max Current Models 121575W rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum 12 vdc 0.152 listed voltage (16v for 24v units). For audibles the max current is usually at UL max 0.255 the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, * see installation instructions. Table 2: AudibleslSpeakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6/G10 Speakers ET-1010/1080, E70, ET70 Chimes CH70 Wiring Diagrams SERIES RSS/RSSP APPLIANCE FROM +___ _______ TO NEXT PRECEDING - APPLIANCE APPLIANCE, SYNC OR EOLR MODULE, POWER SUPPLY OR FACP + H SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE NAC + SYNC CIRCUIT —OUT--F- =RSS RSS SS ROBEL NAC CIRCUIT RETURN STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM _____ _______ ______ + APPLIANCE PRECEDING II II - OR EOLR APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP + - + - STROBE AUDIBLE STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY FROM + + TO NEXT PRECEDING APPLIANCE APPLIANCE OR - __________________ __________ - OR EOLR FACP FROM - 1 1 - - + TO NEXT PRECEDING STROBE OR STROBE. SYNC — - - •1I 1 1 - - EOLR - — MODULE, POWER SUPPLY OR FACP STROBE APPLIANCE SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH WHEELOCK POWER SUPPLIES Series PS Power Supplies rHS nRS S j OUTPUTS ire EOLR 4 - 4-CLASS A OR RSS C 2-CLASS P HS r•;_ I IRSS PS Power 11 For detail using DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83177 for DSM. For wiring information on the power supplies refer to Wheelock Power Supplies. Specifications and Ordering Information Model Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE Mounting Square or Round Agency Approvals - UL MEA CSFM FM BFP RSS-24MCW-FR 940 X - X 15/30/75/110 X - X - B,DE,F,G,HJN,OR,X Square X X X X X RSS-24MCW-FW 9401 X I - X 15/30/75/110 X - - X B,DE,FG,H,J,N,O,R,X Square X X X X X RSS24MCWAR**** 9773 X - X 15/30/75/110 X - - X BDE,FG,HJN,O,R,X Square X X X X X RSS-241575W-FR 7471 X - X 15(75onAxis) X - X - B,DE,F,G,HJ,NOR,X Square X X X X X RSS-241575W-FW 7788 X - X 15(75onAxis) X - - X BD,E,FG,H,J,NO,R,X Square X X X X X RSS-121575W-FR 7476 X - X 15(75onAxis) - X X - B,D,E,F,G,F-IJ,N,O,R,X Square X X X X X RSS-121575W-FW 7468 X - X 15(75onAxis) - X - X B,DEF,G,HJ,NOR,X Square X X X X X RSS-24MCC-FW 3158 - X X 15/30/75/95 X - - X BD,EFG,H,J,NOR,X Square X X X X - RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - B,D,EFGH,J,N,O,R,X Square X X X X - RSS-24MCCH-FW 3461 - X X 115/177 X - - X BD,E,F,G,I-IJN,O,R,X Square X X X X - RSS-24MCWH-FR 3465 X X 135/185 X X BD,E,FQH,J,N,OR,X Square X X X X - RSS-24MCWH-FW 3464 X X 1 135/185 X X B,DE,F,G,HJN,O,R,X Square X X X X - RSSWP2475WFR** 9013 X - X 180@ 77-F X - X - BD,EFGH,J,N,OR,X Square X X X X - RSSWP2475WFW** 3034 X - X 180@ 77-F X - - X B,DE,F,G,HJ,N,O,R,X Square X X X X - RSSP-121575W-FR 7798 X - X 115(75onAxis) - X X - DE,Z Square X - X X X RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X X X X RSSP-241575W-FR 7793 X - X 15 (75 on Axis)j - - X - D,E,Z Square X X I X X X RSSP-24MCWH-FR 9482 X X 135/185 X X BD,E,F,GH,J,N,O,R,X Square X X I X - - All models sync with Wheelock DSM or Wheelock Power Supplies. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options. - **** "A stands for Agent Lettering. S0410 RSS/RSSP 07/11 Cooper Notification is Wheelock* (MEDC) SAFEPATH WAV Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15130175/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE; Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0141 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-W RSS-##C RSSP-##C RSS-#CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, • RSSP-24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *ZRS..MCC *ZRSMCW *ZRSMCCH and *ZRSMC\ Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 16-33VDC/FWR Candela 155cd,157515/75cd on axis, 30=30cd,7575cd, 110=110cd(WaIl) RSS-24MCW, RSSP24MCW,*ZRSMCW: Selectable 15cd,30cd ,75cd orll0cd RSS-24MCC, RSS24MCCR,RSSP24M CC, *ZRSM CC: Selectable 15cd,30cd,75cd and 95cd RSS24MCWH,RSS24MCWHR,RSSP24MCWH,*ZRSMCWH:Selectable 135cd, 1 85c RSS24MCCH,RSS24MCCHR,RSSP24MCCH,*ZRSMCCH:Selectable 115cd,177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models *Rev. 12-13-2006 jw r' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7125-0785:0141 Page 2 of 2 SM-12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. Rev. 12-13-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to Iistee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Series AS Audible Strobe Appliances and Series AH Audibles U'] SERIES AS SERIES AH Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/110cd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30175/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information ADA/NFPA/UFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi- Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 11 5/1 77cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce I flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires For Weatherproof Series AS, See Datasheet 590Q4 ® MEA X <~@> APPROVED E5946 151-92-E 7125-0785;131 S5391 24 VDC Models Audible AH-24 AS-241575W 1575cd High (99) dBA 24 vdc 0.062 0.100 UL max* 0.080 0.121 Med (95) dBA 24 vdc 0.033 0.080 UL max* 0.043 0.107 Low (90) dBA 24 vdc 0.017 0.072 UL max* 0.021 0.100 12 VDC Models Audible Wall Mount Audible Strobe AH-12 I AS-121575W High (99) 12 vdc 0.163 0.260 UL max- 0.192 0.320 dBA Med (95) 12 vdc 0.076 0.195 UL max* 0.108 0.275 dBA Low (90) 12 vdc 0.039 0.175 UL max* 0.058 0.265 dBA NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. .FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology 'Listed Voltage Range". Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/ AH 12 and 24 VDC Audible Reverberant Anechoic Description Volume dBA Per UL 464 dBA @10 ft. @10 ft. High 91 99 Continuous Medium 88 95 Horn Low 83 90 High 87 99 Medium 84 95 Code 3 Horn Low 79 90 Table 1: Ratings Per UL 1971 Model Number Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela (Cd) AS-24MCW 24 16.0 -33.0 15/30/75/110 AS-24MCCH 24 16.0-33.0 115/177 AS-241575W 24 16.0-33.0 15(75onAxis) AS-121575W 12 8.0 -17.5 15 (75 On Axis) AS-24MCC 24 16.0 -33.0 15/30175/95 AS-24MCWH 24 16.0 -33.0 135/185 ASWP-2475W 24 16.0-33.0 75 @ -31°F Table 3: Average RMS Current ill Mount Audible Strobe Models Ceiling Mount Audible Strobe Models AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 1 5c 30cd 75cd hOed 135cd 185cd 15cd 30cd 75cd 95cd hlscd 177cd 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 0.068 0.105 0.182 0.245 0.335 0.460 0.074 0.113 0.198 0.263 0.335 0.460 Table 4: Average Current* (AMPS) For Series ASWP# Voltage High dBA Setting (99) dBA Medium dBA Setting (95) dBA Low dBA Setting (90) dBA 24.0 VDC 0.128 0.105 0.098 UL Max* 0.168 0.155 0.150 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES . DSM #1 Strobe NAC Cir. JAS I F Hø+_ rH0 Audible NAC Cir DSM #2 I Strobe NAC Cir. 12) 5Ycø AS AS DKN C + Audible NAC Cir I DSM #3 F []Sync st Strobe NAC Or Interconnecting wiring shown. Maximum of DSM twenty (20) For detail using DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83177 for DSM. For wiring informationon the power supplies refer to Installation Instructions P84905 for Wheelock Power Supplies. Wiring Diagrams SERIES AS APPLIANCES NON-SYNCHRONIZED FROM TO NEXT APPLIANCE - OR EOLR OR FACP PRECEDING APPLIANCE Snecifications and Orderina Information - Number Model N b Order Code Strobe Candela Non- Sync Sync DSM or Wheelock Power Supplies 24 VDC 12 VDC Wall Mount Ceiling Mount MountingOptions*** Agency Approvals - UL MEA CSFM - FM - BFP AS-24MCW-FR 9024 15/30/75/110 X X X - X - A,B,D,E,FG,H,J,NOR,X X X I X X X AS-24MCW-FW 9025 15/30/75/110 X X X - X - A,B,D,E,F,G,HJ,N,O,R,X X X X X X AS-24MCWH-FR 3468 135/185 X X X - X - A,B,DE,F,GH,JN,O,R,X X X X X - AS-24MCWH-FW 3469 135/185 X X X - X - A,B,D,EFG,H,J,NOR,X X X X X - AS-241575W-FR 7405 15(75onAxis) X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS-121575W-FR 7410 15(75onAxis) X X - X X - A,B,DE,F,G,HJN,O,R,X X X X X X AS-24MCC-FR 3161 15/30/75/95 X X X - - X A,B,D,E,F,G,H,JNO,R,X X X X X - AS-24MCC-FW 3162 15/30/75/95 X X X - - X A,B,D,EFG,H,J,N,O,R,X X X X X - AS-24MCCH-FW 3467 115/177 X X X - - X A,B,D,E,F,GH,J,N,O,R,X X X X X - ASWP2475WFR** 9012 75 @ -31°F X X X - X - I (see Data Sheet S9004) X X X X X AH-24-R 7892 - X X X - X X A,B,D,E,F,G,H,J,NO,R,X X X X X X AH-24-W 7893 - X X X - X X A,BD,E,F,G,HJNO,R,X X X X X X AH-12-R 7891 - X X - X X X A,B,D,EF,GH,JN,O,R,X X X X X X AH-12-W 7894 - X X - X X X A,B,D,E,F,G,H,JNO,R,X X X X X X AH24WPR** 7416 - X X X - X X K X X X - X AH12WPR** 7415 - X X - X X X K X X X - X **For Weatherproof Series AS/AH specifications see data sheet S9004. *PENDING ***Refer to Data Sheet 57000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. S8100 AS/AH 06/11 Notification -Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30175195 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. NEit4 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: 7125-0785:0131 Page 1 of 2 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -Ware for wall mount only. *Models AS-1 21575W and AS-241575W lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -24750 and -241 OOC audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. *Lens color may be white, red, blue, green, or amber. Models ASWP-2475W and *ASWP..2475c audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, *ASWP24MCWH and *ASv/P24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. Refer to the listee's data sheet for detailed product description and operational considerations. *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division - Listing No. 7125-0785:0131 Page 2 of 2 RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:l5cd,1575:15/75cd,30:30cd,75:75cd,95:95cd,100:100cd, 110:ll0cd MCW: Selectable 15cd, 30cd, 75cd,110cd MCC: Selectable 15cd, 30cd,75cd,95cd MCWH: Selectable 135cd,185cd (65cd, 90cd at -40 C) MCCH: Selectable 115cd,177cd (50cd, 75cd at -40 C) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP-24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix -w or WH are for wall mount only. Models with suffix -C or -CH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP, AH-24WP, *ASWp..2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models AH-12, AH-24, -I2WP and -24WP audible devices are not suitable for the hearing - impaired applications. *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 40 Date Issued: July 01, 2015 Listing Expires June 3O,2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division