Loading...
HomeMy WebLinkAbout5600 AVENIDA ENCINAS; ; FPC2023-0128J 1 1 1IsTt4I elock 4L-City of Carlsbad Print Date: 07/22/2024 Permit No: FPC2023-0128 Job Address: 5600 AVENIDA ENCINAS, CARLSBAD, CA 92008-4452 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2100905000 Track #: Applied: 07/21/2023 Valuation: $8,223,037.68 Lot #: Issued: 10/24/2023 Occupancy Group: Project #: DEV2022-0059 Finaled Close Out: 04/05/2024 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix Plan Check #: Cheung, Nathaniel Project Title: 5600 AVENIDA ENCINAS TI Description: VUORI -REVISED PLANS FOR FIRE ALARM NOTIFICATION DEVICES TO BE INSTALLED ON EXISTING ALARM SYSTEM (124 DEVICE (REV 1) Applicant: FPContractor: ELECTRONIC CONTROLS SYSTEM LLC ELECTRONIC CONTROL SYSTEMS LLC RICHARD SAYLORS 12575 KIRKHAM CT 12575 KIRKHAM CT POWAY, CA 92064-8844 POWAY, CA 92064-8844 (858) 513-1911 (858) 513-1911 FEE AMOUNT FIRE Hourly Services (each additional hour) $170.00 FIRE Hourly Services (first hour) $200.00 FIRE Hourly Services (first hour) $200.00 FIRE Hourly Services (first hour) $200.00 FIRE TI Fire Alarm System $735.00 FIRE TI Fire Alarm System $781.00 Total Fees: $2,286.00 Total Payments To Date: $2,086.00 Balance Due: $200.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov -. Albireo Energy Partnering for Success Vuori 5600 Avenida Encinas Carlsbad, CA 92008 I Product Data Submittal Fire Alarm System July 21, 2023 Albireo Energy. 12575 Kirkham Ct • Poway, CA 92064 Phone: 858-513-1911 www.a1bireoenergy.com Albireo Partnering for Success Table of Contents 1. Fire Alarm Equipment N FS-320 PSE-6 FSP-951 FSP-951R DNR FRM-1 SCWL PC2WL Existing Fire Alarm Control Panel (Provided for Reference Only) Remote Notification Power Supply Smoke Detector Smoke Detector for Duct Smoke Duct Smoke Detector Control Relay Ceiling Mount Strobe Ceiling Mount Speaker Strobe Albireo Energy• 12575 Kirkham Ct Poway, CA 92064 • Phone: 858-513-1911 • www.albireoenergy.com 0 NoTIFIER® by Honeywell NFS-320 Intelligent Addressable Fire Alarm Control Panel General The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products meet virtually every application requirement. The NFS-320's modular design makes system planning easier. The panel can be configured with just a few devices for small building applications, or networked with many devices to protect a large cam- pus or a high-rise office block. Simply add additional peripheral equipment to suit the application. Wireless fire protection can be added with the SWIFT wireless gateway and devices. For installations using NFS-320C, an optional ACM Series annunci- ator can be mounted in the same cabinet (up to 48 zones/points, order separately; see DN-60085). NOTE: Unless called out with a version-specific "R", "C" or "E" at the end of the part number, "NFS-320" refers to models NFS-320, NFS-320R, NFS-320C, and NFS-320E. ONYX® Series panels integrate with the Connected Life Safety Ser- vices (CLSS) platform through the CLSS Gateway, providing connectivity to central station, cloud, and mobile applications. (See HON-62034.) This cloud-based functionality provides reliable pro- tection and remote monitoring of the system, reduced manual data entry, and reporting. Features Certified for seismic applications when used with the appropriate seismic mounting kit. Approved for Marine applications when used with listed compati- ble equipment. See DN-60688. One isolated intelligent Signaling Line Circuit (SLC) Class A, B, or X. Wireless fire protection using SWIFT Smart Wireless Integrated Fire Technology. See DN-60820. Up to 159 detectors and 159 modules per SLC; 318 devices max- imum. - Detectors can be any mix of photo, thermal, or multi-sensor; wireless detectors are available for use with the FWSG(A). - Modules include addressable pull stations, normally open con- tact devices, two-wire smoke detectors, notification, or relay; wireless modules are available for use with the FWSG(A). Standard 80-character display. Network options: - High-speed network for up to 200 nodes (N16e/x, NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCD, NCA-2, DVC-EM, ONYXWorks, NFS-3030, NFS-640, and NCA). -Standard network for up to 103 nodes (N16e/x, NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCD, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP- 300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC- EM is used in network paging. 6.0 A power supply with four Class A/B built-in Notification Appli- ance Circuits (NAC). Selectable System Sensor, Wheelock, or Gentex strobe synchronization. Built-in Alarm, Trouble, Security, and Supervisory relays. VeriFire® Tools online or offline programming utility. Upload! Download, save, store, check, compare, and simulate panel data- bases. Upgrade panel firmware. Autoprogramming and Walk Test reports. Multiple central station communication options: - Standard UDACT - Internet - Internet/GSM 80-character remote annunciators (up to 32). EIA-485 annunciators, including custom graphics. Printer interlace (80-column and 40-column printers). History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. Alarm Verification selection per point, with automatic counter. Presignal/Positive Alarm Sequence (PAS). Silence inhibit and Auto Silence timer options. NAC coding functions: - March time. - Temporal. - California two-stage coding. - Canadian two-stage. - Strobe synchronization. Optional cloud connectivity for remote off site monitoring through CLSS (see HON-62034) Monitor multiple buildings through one off-campus central station, and report through the CLSS Gateway Optional remote programing through CLSS Field-programmable on panel or on PC with VeriFire® Tools pro- gram check, compare, simulate. Full QWERTY keypad. Battery charger supports 18 - 200 AH batteries. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitor mod- ules. Automatic time control functions, with holiday exceptions. Extensive, built-in transient protection. Powerful Boolean logic equations. DN-71 12:Q • 9/14/2022 - Page 1 017 SWIFT WIRELESS Self-healing mesh wireless protocol. Each SWIFT Gateway supports up to 49 SWIFT devices. Up to 4 wireless gateways can be installed with overlapping net- work coverage. RELEASING FEATURES Ten independent hazards. Sophisticated cross-zone (three options). Delay timer and Discharge timers (adjustable). Abort (four options). Low-pressure CO2 listed. VOICE FEATURES Integrates with FirstCommand Series. See DN-60772. Telephone applications require NFC-FFT. HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 A POWER SUPPLY (6.0 A IN ALARM) 120 VAC (NFS-320/NFS-320C); 240 VAC (NFS-320E). Displays battery current/voltage on panel (with display). FLASHSCAN® INTELLIGENT FEATURES Polls up to 318 devices in less than two seconds. Activates up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Patent 5,539,389). Manual sensitivity adjustment - up to nine levels. Pre-alarm ONYX intelligent sensing - up to nine levels. Day/Night automatic sensitivity adjustment. Sensitivity levels: - Photo - 0.5 to 2.35%/foot obscuration. Up to 32 remote displays - High-Sensitivity Photoelectric (VIEW®) - Open Air Protection (0.5% - 2.0%/ft. obscuration), Special Applications (0.02%- 0.50/./ft. obscuration) - Multi-Criteria Detector - Open Air Protection (2.52-3.890/./ft. obscuration), Special Applications (1.13-2.52%/ft. obscuration) Drift compensation (U.S. Patent 5,764,142). Degraded mode: In the unlikely event that the NFS-320's primary microprocessor fails, FlashScan detectors revert to degraded operation and can activate the control panel's NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Dis- able/Enable switch for this feature. Multi-detector algorithm involves nearby detectors in alarm deci- sion (U.S. Patent 5,627,515). Automatic detector sensitivity testing (NFPA-72 compliant). Maintenance alert (two levels). Self-optimizing pre-alarm. FSV-951 SERIES VIEI4® (VERY INTELLIGENT EARLY WARNING) HIGH-SENSITIVITY SMOKE DETECTOR Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals. Addressable operation pinpoints the fire location. Ivory models (-IV) support CLIP mode as well as FlashScan. ULC listed models available; "A" models are ULC Listed. -R is retrofit, backwards compatible for use with older panels. FCO-951/-IV ADVANCED MULTI-CRITERIA FIR&'CO DETECTOR Detects all four major elements of a fire (smoke, heat, CO, and flame). 135°F (57.2°C) fixed-temperature heat detector. Transmits an alarm signal due to heat. Separate signal for life-safety CO detection. SLC Intelligent Loop DEVICES I - - 10000 FPTI-951 - . FDU-80 LCD2-80 FCO-951 . . . etc. EIA-485 EIA-485 FWSG NBG-12LX 'f 4, XP6/10 FMM-1 FCM-1 Input/Output Modules IDC j NAC F'RM-1 Relay Contact 2048 annunciator/control points U. U. U. U. ACM-8R Relay Control $I1!I;I$lII ACM/AEM-24AT LED Annunciator LL±J LDM-32 Custom Graphics Sample System EIA-232 Options Dual phone lines to Optional 318-point UDACT Central Station 7112blok-2014.wmf PRN Series Printer Page 2 of 7— DNJ-7112:0 • 9/14/2022 Optional addressable sounder base for Temp-3 (fire) or Temp-4 (CO) tone. Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. ULC listed models available; -A models are ULC Listed. FPTI-951(A) INTELLIGENT MULTI-CRITERIA DETECTOR Combined photoelectric, thermal, and infrared sensor UL 268 7th Edition and UL 521 Listed; Canadian models CAN/ ULC S529 and CAN/ULC S530 Microprocessor-based technology; combination photo, thermal, and infrared technology. FPC-951(A) PHOTOELECTRIC/CO SENSOR Combined photoelectric and carbon monoxide sensor FSCO-95(A) INTELLIGENT CO SENSOR Carbon monoxide sensor FS-OSI-RI(A) ADDRESSABLE INTELLIGENT SINGLE-ENDED BEAM SMOKE DETECTOR Intelligent addressable reflector-type linear optical beam smoke detector Fast, easy, and intuitive beam alignment indicated by directional LED arrows Long range coverage of 16-328 ft (5-loom) is standard; no sepa- rate long-range kit required INTELLIGENT VESDA-E DETECTORS Intelligent aspiration smoke detectors connect directly to the SLC loop of compatible ONYX® Series panels: - VEA-040-AOO-NTF, VEA-040-A1O-NTF - VEP-AOO-P-NTF, VEP-Al O-P-NTF, VEP-A00-1 P-NTF - VEU-AOO-NTF, VEU-A10-NTF - VES-AOO-P-NTF-UL, VES-A10-P-NTF-UL Models offer LED display, LCD display, or both Coverage options for spaces up to 69,965 square feet FlashScan, Exclusive World-Leading Detector Protocol At the heart of the NFS-320 is a set of detection devices and device protocol - FlashScan (U.S. Patent 5,539,389). FlashScan is an all- digital protocol that gives superior precision and high noise immu- nity. In addition to providing quick identification of an active input device, this protocol can also activate many output devices in a fraction of the time required by competitive protocols. This high speed also allows the NFS-320 to have the largest device per loop capacity in the industry - 318 points - yet every input and output device is sampled in less than two seconds. The microprocessor-based FlashScan detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing Intelligent sensing is a set of software algorithms that provides the NFS-320 with industry-leading smoke detection capability. These complex algorithms require many calculations on each reading of each detector, and are made possible by the high-speed microcom- puter used by the NFS-320. Drift Compensation and Smoothing: Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces mainte- nance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, such as those caused by electrical interference. Maintenance Warnings: When the drift compensation performed for a detector reaches a certain level, the performance of the detec- tor may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust: Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automat- ically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predetermined levels of alarm. Pre-alarm operation can be latching or self-restoring, and can be used to acti- vate special control functions. Self-Optimizing Pre-Alarm: Each detector may be set for "Self- Optimizing" pre-alarm. In this special mode, the detector 'learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level lust above these normal peaks. Cooperating Multi-Detector Sensing: A patented feature of ONYX intelligent sensing is the ability of a smoke sensor to consider read- ings from nearby sensors in making alarm or pre-alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram is a timesaving feature. The FACP "learns" what devices are physically connected and automatically loads them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installation, even if only a portion of the detectors are installed. Keypad Program Edit (with KDM-R2) The NFS-320, like all NOTI- FIER intelligent panels, has the exclusive feature of program cre- ation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS- 320 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the pro- gram to be entered with independent per-point segments, while the NFS-320 simultaneously monitors other (already installed) points for alarm conditions. VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confi- dence in the site-specific software. It is Windows®based and pro- vides technologically advanced capabilities to aid the installer. The installer may create the entire program for the NFS-320 in the com- fort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. Placement of Equipment in Chassis and Cabinet The following guidelines outline the NFS-320's flexible system design. Wiring: When designing the cabinet layout, consider separation of power-limited and non-power-limited wiring as discussed in the NFS-320 Installation Manual. It is critical that all mounting holes of the NFS-320 are secured with a screw or standoff to ensure continuity of Earth Ground. Networking: If networking two or more control panels, each unit requires a Network Communication Module or High-Speed Network Communication Module (HS-NCM can support two nodes; see "Net- working Options" on page 4). These modules can be installed in any DN-71 12:Q • 9/14/2022 - Page 3 of 7 option board position (see manual), and additional option boards can be mounted in front of them. KDM.R2 Controls and Indicators Program Keypad: OWERTY type (keyboard layout). 12 LED Indicators: Power; Fire Alarm; Pre-Alarm; Security; Super- visory; System Trouble; Signals Silenced; Points Disabled; Control Active; Abort; Pre-Discharge; Discharge. Product Line Information "Configuration Guidelines" on page 4 "Main System Components" on page 4 "Networking Options" on page 4 "Auxiliary Power Supplies and Batteries" on page 4 "Audio Options" on page 4 "Compatible Devices, EIA-232 Ports" on page 4 "Compatible Devices, EIA-485 Ports" on page 4 "Compatible Intelligent Devices" on page 5 'Enclosures, Chassis, and Dress Plates" on page 6 "Other Options" on page 6 CONFIGURATION GUIDELINES The NFS-320 system ships assembled; description and some options follow. See "Enclosures, Chassis, and Dress Plates" on page 6 for information about mounting peripherals. Stand-alone and network systems require a main display. On stand- alone systems, the panel's keypad provides the required display. On network systems (two or more networked fire panel nodes), at least one NCD, NCA-2/C, NCS, or ONYX Works annunciation device is required. (For NCA-2, see DN-7047. For NCD, see DN-60974.) MAIN SYSTEM COMPONENTS NFS-320: The standard, factory-assembled NFS-320 system includes the following components: one control panel mounted on chassis (120 V operation - ships with grounding cable, battery interconnect cables, and document kit); includes integral power sup- ply mounted to the main circuit board; one primary display KDM-R2 keypad/display; and one cabinet for surface or semi-flush mounting. Purchase batteries separately. One or two option boards may be mounted inside the NFS-320 cabinet; additional option boards can be used in remote cabinets. (Non-English versions also available. NFS-320-SP, NFS-320-PO.) NFS-320R: Same as NFS-320, but in red enclosure. NFS-320C: Based on NFS-320 above. NFS-320C supports installa- tion of an optional ACM-series annunciator in the same cabinet. UL- and ULC-listed. (Non-English version also available: NFS-320C- FR.) For NFS-320C, see DN-60085. NFS-320CR: Same as NFS-320C but in a red enclosure. For NFS- 320C, see DN-60085. NFS-320E: Same as NFS-320, but with 240 V operation. (Non- English versions also available. NFS-320E-SP, NFS-320E-PO.) TR-320: Trim ring for the NFS-320 cabinet. NETWORKING OPTIONS NCM-W, NCM-F: Standard Network Communications Modules. Wire and multi-mode fiber versions available. See DN-6861. HS-NCM-W(-2), HS-NCM-MF, HS-NCM-SF, HS-NCM-WMF(-2), HS-NCM-WSF(-2), HS-NCM-MFSF: High-speed Network Commu- nications Modules. Wire, single-mode fiber, multi-mode fiber, and media conversion models are available. See DN-60454. RPT-W, RPT-F, RPT-WF: Standard-network repeater board with wire connection (RPT-W), multi-mode fiber connection (RPT-F), or allow- ing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks. See DN-6971. ONYXWorks: UL-listed graphics PC workstation, software, and computer hardware. See DN-7048 for specific part numbers. NFN-GW-EM-3: NFN Gateway, embedded. See DN-60499. NWS-3: NOTI'FIRE.NETTM Web Server. See DN-6928.. VESDA-HLI-GW: VESDAnet high-level interface gateway. See ON- 60753. LEDSIGN-GW: UL-listed sign gateway. Interfaces with classic and high-speed NOTI•FIRE•NET networks through the NFN Gateway. See DN-60679. OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW. See ON- 60679. AUXILIARY POWER SUPPLIES AND BATTERIES ACPS-610: 6.0 A or 10.0 A addressable charging power supply. See DN-60244. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and transfer relay, and overcurrent protection. Mounts on two of four positions on a CHS-4L or CHS-4 chassis. See DN-5952. FCPS-24S6/S8: Remote 6 A and 8 A power supplies with battery charger. See DN-6927. BAT Series: Batteries. NFS-320 uses two 12 volt, 1810200 AH bat- teries. See DN-6933. AUDIO OPTIONS NFC-50/100: 25 watt, 25 VRMS, emergency Voice Evacuation Con- trol Panel (VECP) with integral commercial microphone, digital mes- sage generator, and Class A or Class B speaker circuits. See DN- 60772. COMPATIBLE DEVICES, EIA -232 PORTS PRN-7: 80-column printer. See DN-60897. VS4095/5: Printer, 40-column, 24 V. Mounted in external backbox. See DN-3260. DPI-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACP5 and/or peripherals; mount on NFS-320 chassis. See DN-6870. COMPATIBLE DEVICES, EIA -485 PORTS ACM-24AT: ONYX Series ACS annunciator -24 points, expandable to 64 of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by pow- ered-up switch selection) by point to be red, green, or yellow; the Trouble LED is always yellow. See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT, expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM-48A: ONYX Series ACS annunciator - 48 points, expandable to 64 of annunciation with Alarm or Active LED per circuit. Active/ Alarm LEDs can be programmed (by powered-up switch selection) in groups of 24 to be red, green, or yellow. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A, expands the ACM- 48A to 96 points. See DN-6862. ACM-BR: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See DN- 3558. FDU-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See ON- 6820. Keypad Switch Controls: Acknowledge/Scroll Display; Signal CAP-GW: Common Alerting Protocol Gateway. See DN-60756. Silence; Drill; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long-life LED backlight. Page 4 of 7-ON-71 12:0 • 9/14/2022 LCD2-80: Terminal and ACS mode. 80-character, backlit LCD dis- play. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See DN-60548. LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM-R32; remote custom driver modules. See DN-0551. SCS: Smoke control stations SCS-8, SCE-8, with lamp drivers SCS- 8L, SCE-8L; eight (expandable to 16) circuits (HVAC only). See DN- 48 18. TM-4: Transmitter Module. Includes three reverse-polarity circuits and one municipal box circuit; mount on NFS-320 chassis or remotely. See DN-6860. UDACT-2: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-60686. UZC-256: Programmable Universal Zone Coder provides positive non-interfering successive zone coding. Microprocessor-controlled, field-programmable from lBM®compatibIe PCs (requires optional programming kit). Mounts in BB-UZC. See DN-3404. COMPATIBLE INTELLIGENT DEWCES NOTE: "A" suffix indicates ULC-Listed model: FWSG(A) Wireless SWIFT Gateway: Addressable gateway sup- ports wireless SLC devices. Order FWSGA for ULC applications. See DN-60820. FCO-951/-IV FlashScan, Addressable intelligent multi-criteria smoke sensors, photo, carbon monoxide, fixed temperature heat detector and infra-red (IR). ULC: FCO-951N-IV FPC-951. FlashScan, Combined photoelectric and carbon monoxide sensor. ULC: FPC-951A. FSCO-951. FlashScan, Addressable carbon monoxide sensor. ULC: FSCO-951 A. FPTI-951, FPTI-951-IV: Addressable intelligent multi-criteria photo- electric, thermal and IR sensors. ULC: FPTI-951A, FPTl-951A-IV. FS-OSI-RlAddressable intelligent single-ended beam smoke detec- tor. ULC: FS-OSI-RIA. FSP-951: White, low-profile intelligent photoelectric sensor, FlashScan only. ULC: FSP-951A. FSP-951-IV: Ivory, low-profile intelligent photoelectric sensor. ULC: FSP-951A-IV FSP-951T: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FlashScan only. ULC: FSP-951TA. FSP-951T-IV: Ivory, same as FSP-951T but includes a built-in 135°F (57°C) fixed-temperature thermal device. ULC: FSP-951TA-IV. FSP-951R: White, low-profile intelligent photoelectric sensor, remote test capable. For use with DNRIDNRW. FlashScan only. ULC: FSP- 95RA FSP-951 R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable. FlashScan only. ULC: FSP-95RA-IV, for use with DNRA. FST-951: White, low-profile intelligent 135°F fixed thermal sensor, FlashScan only. Must be mounted to one of the bases listed below. ULC: FST-951A. See DN-60975. FST-951-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, FlashScan and CLIP. Must be mounted to one of the bases listed below. ULC: FST-951A-IV. FST-951 R: White, low-profile intelligent rate-of-rise thermal sensor, FlashScan only. Must be mounted to one of the bases listed below. ULC: FST-951A FSP-951 R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable. FlashScan only. ULC: FSP-95RA-IV, for use with DNRA. FST-951H: White, low-profile intelligent 190°F fixed thermal sensor, FlashScan only. Must be mounted to one of the bases listed below. ULC: FST-951 HA. FST-951 H-IV: Ivory, low-profile intelligent 190°F thermal sensor, FlashScan and CLIP. Must be mounted to one of the bases listed below. ULC: FST-951HA-IV. FSV-951, FSV-951 R:White, intelligent high-sensitivity photoelectric smoke detector. ULC: FSV-951A, FSV-951 RA FSV-951-IV, FSV-951 R-IVIvory, intelligent high-sensitivity photoelec- tric smoke detector. ULC: FSV-951A-IV, FSV-951RA-IV. VEP-AOO-P-NTF: Intelligent aspiration smoke detector with LED dis- play, 4 pipes, covers up to 21,520 square feet. See DN-61029. UL/ ULC Listed. VEP-AllO-P-NTF: Intelligent aspiration smoke detector with LED and LCD display, 4 pipes, covers up to 21,520 square feet. See ON- 61029. ULIULC Listed. VEP-A00-1P-NTF: Intelligent aspiration smoke detector with LED display, single pipe, covers up to 10,760 square feet. See ON- 61029. UL/ULC Listed. VEU-AOO-NTF: Intelligent aspiration smoke detector with LED dis- play, 4 pipes, covers up to 69,965 square feet. See DN-61034. UL/ ULC Listed. VEU-A10-NTF: Intelligent aspiration smoke detector with LED and LCD display, 4 pipes, covers up to 69,965 square feet. See ON- 61034. UL'ULC Listed. VEA-040-AOO-NTF: Intelligent aspiration with LED display, 40 point- addressable detection points. Covers 36,000 square feet. See ON- 61036. UL/ULC Listed. VEA-040-AlO-NTF: Intelligent aspiration with LED and LCD display, 40 point-addressable detection points. Covers 36,000 square feet. See DN-6 1036. ULJULC Listed. VES-A00-P-NTF-UL: Intelligent scanning aspiration detector with LEDs. See DN-62040. UL 268 7th edition. VES-A10-P-NTF-UL: Intelligent scanning aspiration detector with 3.5" display. See DN-62040. UL 268 7th edition. DNR: jnnovairFlex low-flow non-relay duct-detector housing. ULC: DNRA. (Order FSP-951 R(A) separately.) See DN-60429. DNRW: Same as above with NEMA-4 rating, watertight. See DN- 60429. B224RB-WH: White, low-profile relay base. See DN-60054. ULC: B224RBA-WH. B224RB-IV: Ivory, plug-in System Sensor relay base. ULC: B224RBA-IV. B224B1-WH: White, isolator base for low-profile detectors. See ON- 60054. ULC: B224B1A-WH. B224B1-IV: Ivory isolator detector base. ULC: B224BIA-IV. B300-6: White, standard flanged low-profile mounting base. (For 10- pack order B300-6-BP.) ULC: B300A-6. B300-6-IV: Ivory, standard flanged low-profile mounting base. ULC: B300A-6-IV. B501 -WHITE: European-style, 4' (10.16 cm) base. See DN-60054. (For 10-pack order B501-WHITE-BP.) UL/ULC listed. B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. B501-IV: Ivory color, 4" standard European flangeless mounting base. ULJULC listed. B200S-WH: White, intelligent programmable sounder base, capable of producing a variety of tone patterns including ANSI Temporal 3. Compatible with synchronization protocol. See DN-60054. ULC: B200SA-WH. B2005-IV: Ivory intelligent, programmable sounder base. ULC: B200SA-IV. ON-7112:Q • 9/14/2022 - Page 5 of 7 B200SCOA-WH: White intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO detectors. Based on B200SA. ULC listed. B200SCOA-IV: Ivory intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO detectors. Based on B200SA. ULC listed. B200S-LF-WH: White, low-frequency version of B200S. See DN- 60054. B200S-LF-IV: Ivory, low-frequency version of B200S. B200SR-WH: White intelligent programmable sounder base, Tem- poral 3 or Continuous tone. For retrofit installations replacing B501 BH series bases. See DN-60054. ULC: B200SRA-WH. B200SR-IV: Ivory intelligent programmable sounder base, Temporal 3 or Continuous tone. For retrofit installations replacing B501BH series bases. ULC: B200SRA-IV. B200SR-LF-WH: White, low-frequency version of B200SR. See ON- 60054. B200SR-LF-IV: Ivory, low-frequency version of B200SR. FMM-1: FlashScan monitor module. See DN-6 720. FDM-1(A): FlashScan dual monitor module. See DN-6 720. FZM-1(A): FlashScan two-wire detector monitor module. See DN- 6720. FMM-101(A): FlashScan miniature monitor module. See DN-6 720. FCM.1(A): FlashScan control module. See DN-6 724. FCM-i-REL(A): FlashScan releasing control module. See DN- 60390. FRM-1(A): FlashScan relay module. See DN-6724. FDRM-1(A): FlashScan dual monitor/dual relay module. See ON- 60709. NBG-12LX: Manual pull station, addressable. See ON-6 726. N-MPS series: Manual pull stations, addressable and conventional. For use in Canada only. See DN-5497 and DN-60629. ISO-X(A): Isolator module. See DN-2243. ISO-6(A): Six fault isolator module. See ON-60844. XP6-C(A): FlashScan six-circuit supervised control module. See DN-6924. XP6-MA(A): FlashScan six-zone interface module; connects intelli- gent alarm system to two-wire conventional detection zone. See DN- 6925. XP6-R(A): FlashScan six-relay (Form-C) control module. See ON- 6926. XP10-M(A): FlashScan ten-input monitor module. See ON-6923. ENCLOSURES, CHASSIS, AND DRESS PLATES CAB-BM Marine System: Protects equipment in shipboard and waterfront applications. Also order BB-MB for systems using 100 AH batteries. For a full list of required and optional equipment, see DN-60688. NFS-LBB: Battery Box (required for batteries larger than 26 AH). NFS-LBBR: Same as above, but red. SEISKIT-320/B26: Seismic mounting kit. Required for seismic-certi- fied applications with NFS-320 and BB-26. Includes battery bracket for two 26 AH batteries. SEISKIT-BB25: Seismic mounting kit for the BB-25. Includes battery bracket for two 26 AH batteries. SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AH batteries. Backboxes NOTE: "C" suffix indicates ULC-Listed mode. ABF-i B Annunciator Flush Box. ABF-i DB(C) Annunciator Flush Box with Door. ABF-2B Annunciator Flush Box ABF-2DB(C) Annunciator Flush Box with Door ABF-4B Annunciator Flush Box ABS-1 TB(C) Annunciator Surface Box ABS-1 B(C) Annunciator Surface Box ABS-2B Annunciator Surface Box ABS-21)(C) Annunciator Surface Box ABS-41)(C) Annunciator Surface Box BB-UZC: Backbox for housing the UZC-256. Required for NFS-320 applications. Black. For red, order BB-UZC-R. OTHER OPTIONS CGW-MB: CLSS Gateway for Internet/cloud-based communication between the FACP and peripheral devices. See HON-62034. HON-CGW-MBB: CLSS Gateway, pre-installed in a cabinet. See HON-62034. 411: Slave Digital Alarm Communicator. See DN-6619. 411UDAC: Digital Alarm Communicator. See DN-6746. IPDACT-212UD, IPDACT Internet Monitoring Module: Connects to primary and secondary DACT telephone output ports for internet communications over customer-provided Ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. See DN-60408. IPSPLT: V-adapter option allow connection of both panel dialer out- puts to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket; Red. For Black order IPENC-B. HWF2V-COM: LTE Digital Cellular Fire Alarm Communicator and Internet Panel, Verizon LTE / IP. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Con- nects to the primary and secondary ports of a DACT. See DH-62010. (For Canadian applications order IPGSM-4GC. See DH-60771.) HWF2A-COM: LTE Digital Cellular Fire Alarm Communicator and Internet Panel, AT&T LTE I IP. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Con- nects to the primary and secondary ports of a DACT. (For Canadian applications order IPGSM-4GC. See OH-60771.) NFS-320-RB: Replacement board with central processing unit (CPU). NOTE: Keypad must be removed before shipping old unit out for repair. NFS-320-RBE: Replacement CPU, Export. NFS-320-RB-PO: Replacement CPU, Portuguese. NFS-320-RB-POE: Replacement CPU, Export, Portuguese. NFS-320-RBC-FR: Replacement CPU, Canadian French. NFS-320-RB-SP: Replacement CPU, Spanish. NFS-320-RB-SPE: Replacement CPU, Export, Spanish. NOTE: For other options including compatibility with retrofit equipment, refer to the panel's installation manual, the SLC manual, and the Device Compatibility Document. Page 6 of 7-ON-71 12:0 • 9/14/2022 SPECIFICATIONS SYSTEM CAPACITY Intelligent Signaling Line Circuits .......................................1 Intelligent detectors .......................................................159 Addressable monitor/control modules ............................159 Programmable internal hardware and output circuits ........4 Programmable software zones ............ ............................. 99 Special programming zones.............................................14 LCD annunciators per NFS-320/-320E ............................32 ACS annunciators per NFS-320/-320E .....................32 addresses x 64 points ELECTRICAL SPECIFICATIONS Primary input power: - NFS-320: 120 VAC, 50/60 Hz, 5.0 A. - NFS-320E: 220/240 VAC, 50/60 Hz, 2.5 A. Current draw (standby/alarm): - NFS-320(E) board: 0.250 A. Add 0.035 A for each NAC in use. - KDM-R2 (Backlight on): 0.100 A. Total output 24 V power: 6.0 A in alarm. NOTE: The power supply has a total of 6.0 A of available power. This is shared by all internal circuits. See Installation Manual for a complete cur- rent draw calculation sheet. Standard notification circuits (4): 1.5 A each. Resettable regulated 24V power: 1.25 A. Two non-resettable regulated 24V power outputs: —1.25 A. - 0.50 A. Non-resettable 5V power: 0.15 A. Battery charger range: 18 AH —200 AH. Use separate cabinet for batteries over 26 AH. Float rate: 27.6 V. CABINET SPECIFICATIONS NFS-320 cabinet dimensions: Backbox: 18.12 in. (46.025 cm) width; 18.12 in. (46.025 cm) height; 5.81 in. (14.76 cm) depth. Door: 18.187 in. (46.195 cm) width; 18.40 in. (46.736 cm) height; 0.75 in. (1.905 cm) depth. Trim ring: Molding width is 0.905 in. (2.299 cm). Shipping weight (without batteries): 36.15 lb. (16.4 kg). TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the systems standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to the basic NFS-320 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listed: S635. FM Approved. CSFM: 7165-0028:0243. Fire Dept. of New York: COA# 6212. City of Chicago. NOTE: For additional information on NFS-320C, see DN-60085. For information on NFS-320SYS, see DN-60637. Marine Applications: Marine approved systems must be config- ured using components itemized in this document. (See Main Sys- tem Components, in "Product Line Information.) Specific connections and requirements for those components are described in the installation document, PN 54756. When these requirements are followed, systems are approved by the following agencies: US Coast Guard 161.002/50/0, 161.002/55/0 (Standard 46 CFR and 161 .002). Lloyds Register 11/600013 (ENV 3 category). American Bureau of Shipping (ABS) Type Approval. NOTE: For information on marine applications, see DN-60688. STANDARDS The NFS-320 complies with the following UL Standards and NFPA 72, International Building Code (IBC), and California Building Code (CBC) Fire Alarm Systems requirements: UL 864, 10th edition (Control Units and Accessories for Fire Alarm Systems). UL 2610 (Commercial Premises Security Alarm Units and Systems). UL 2572 (Mass Notification Systems). (NFS-320 version 20 or higher). ULC-5527-11 Standard for the Installation of Fire Alarm Sys- tems. LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). AUXILIARY (Automatic, Manual and Waterflow) (requires TM-4). REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires TM-4). PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). Not applicable for FM. CENTRAL STATION (Automatic, Manual, Waterflow and Sprin- kler Supervisory) (requires DACT). EMERGENCY VOICE/ALARM. OT, PSDN (Other Technologies, Packet-switched Data Network). IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). CBC 2007 (Seismic). 11111111ifififfla & MUt1E QUALITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. WI specifications are subject to change without notice. NOTI.FIRE.NET'5, ONYXWnrtos' and SWIFP are all trademarks 01 and FlanhS- N OTI Fl ER car®, NOTtFtEA®\ ONYX®, VeriFrrnOtToob, and OIEW® are all registered trademarks of 12 Clintonville Road Honeywell International Inc 00022 by Honeywell International Inc All rights resarsed. Unainhorized use of this docu- Northford, CT 06472 mentin strictly prohiboed. 203.484.7161 www.notifier.com Country of Origin: USA NOTIFIER® by Honeywell NOTIFIER® by Honeywell PSE-6/PSE-1 0 Series 6/10 Amp, 24 Volt Power Supply Expanders General The PS Series is a remote power supply line from NOTIFIER and is a direct replacement for the FCPS-24S6/8 Series. The PSE-6(C)(E) is a 6 amp and the PSE-1 0(C)(E) is a 10 amp, remote power supply with battery charger that may be connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notification appli- ance circuits) configured as either Class B or Class A (requires the ZNAC-PS option card) with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and other fire alarm sys- tem peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabi- net. The PSE-6E and PSE-10E are models rated for 240V opera- tion. Features Up to five (6 amp model) or seven (10 amp model) inde- pendently-configurable, power-limited output circuits for: - Class B and/or Class A NACs - Class B and/or Class A resettable or non-resettable 24V auxil- iary power - door holder power Converts from Class B to Class A wiring without losing any out- puts using the ZNAC-PS converter card (sold separately) Optimal for powering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated power Configurable for ANSI® Temporal 3 or Temporal 4 coded output UL-Listed NAC synchronization using System Sensor®, Whee- lock®, Gentex®, orAMSECO® appliances Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet Ability to cascade up to four power supplies Two (6 amp model) or three (10 amp model) fully-isolated input/ control circuits which can be programmed to any output Two Form C normally-closed trouble relays for AC Trouble and General Trouble, Ground Fault relay available on Canadian mod- els only 6 or 10 amp full load output, respectively, with 3 A maximum/cir- cuit Individual NAC power and trouble LEDs for diagnostic efficiency Trouble history modes for diagnostic support Wide range end-of-line supervision value (normal: 2K-27K ohms) Selectable earth fault detection (enable or disable) AC trouble report delay timer Completely configurable via onboard DIP switches, no extra soft- ware required Self-contained in compact, locking cabinet constructed of heavy gauge steel with a corrosion-resistant powder coat chip and scratch-resistant finish Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring Includes integral battery charger capable of charging up to 33 AH batteries Cabinet can house two 7 AF-I or 18 AF-I batteries Battery charger may be disabled via DIP switch for applications requiring larger batteries and external battery charger Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire Works with any UL 864 FACP which utilizes an industry-standard reverse-polarity notification circuit Optional devices include addressable control, monitor, and relay modules and power-supervision relay (EOLR-1) Standards and Codes The PSE Series comply with the following standards: NFPA 72 National Fire Alarm Code UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode), 10th Edition UL 1481 Power Supplies for Fire Alarm Systems IBC 2009 (when using SEISKIT-MULTI-1) CBC 2007 (when using SEISKIT-MULTI-1) Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635, S674 ULC Listed: S635 (PSE-6/10C) CSFM Approved: 7315-0028:0513 FDNY Approved FM Approved DN-61092:C .3/10/2021—Page 1 of 2 SPECIFICATIONS Primary (AC) Power: PSE-6(C): 120 VAC, 50/60 Hz, 5.OA maximum PSE-10(C): I20VAC, 50/60 Hz, 6.2A maximum PSE-6E: 240 VAC, 50/60 Hz, 2.7A maximum PSE-10E: 240 VAC, 50/60 Hz, 3.5A maximum Wire Size: #12-14AWG with 600 V insulation Command Input Circuit: Trigger Input Voltage: 9 to 32 VDC Trigger Current: 2.0 mA(16 - 32 V); Per Input: 1.0 mA (9- 16 V) Trouble Contact Rating: 4 A at 24 VDC Output Circuits: 24 VDC filtered, regulated PSE-6: TB8-TB9 - 1A Regulated, 3A special applications; TB10- TB12 - 0.3A Regulated, 3A special applications PSE-10: TB8-TB11 - 1.5A Regulated, 3A special applications; TB12-TB14 - 0.3A Regulated, 3A special applications 6.0 A (PSE-6) or 10.0 A (PSE-1 0) maximum total continuous cur- rent for all outputs Secondary Power (Battery) Charging Circuit: Supports lead-acid batteries only Float-charge voltage: 27.6 VDC Maximum current charge: 1.5 A Maximum battery capacity: 18 AH (inside cabinet) Maximum battery charging capacity: 33 AH (external cabinet) Physical: Dimensions: 20.0K x 14.5W x 3.5"D (cm: 50.8H x 36.83W x 8.9D) Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two 18AH batteries is 39 pounds (17.7 kg) Ordering Information @P E-6: 6.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure PSE-6C: Same as above, ULC-listed model PSE-6R: Same as PSE-6 with red enclosure PSE-6E: 6.0 A, 240 VAC remote charger power supply in a lock- able, metal enclosure PSE-lO: 10.0 A, 120 VAC remote charger power supply in a lock- able, metal enclosure PSE-IOC: Same as above, ULC-listed model PSE-10R: Same as PSE-10 with red enclosure PSE-10E: 10.0 A, 240 VAC remote charger power supply in a lock- able, metal enclosure ZNAC-PS: Optional Class A output converter module FCM-1: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external 24 VDC to power notifica- tion appliances. FIRMA: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch FMM-1: Addressable Monitor Module for one zone of normally open dry-contact initiating devices. Includes plastic cover plate and end- of-line resistor. Module may be configured for either a Class B or Class A IDC. FDM-1: Dual Monitor Module. Same as FMM-1 except it provides two inputs for Class B wiring only FDRM-1: Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only. XP6-C: Six-circuit supervised control module XP6-R: Six Form-C relay control module EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270-BP: Battery, 12 volt, 7.0 AH, 5-pack (two required, see BAT Series data sheet DN-6933). BAT-12180-BP: Battery, 12 volt, 18AH, 2-pack BAT-12330: Battery, 12 volt, 33AH SEISKIT-MULTI-1: Seismic kit for the PSE Series. Includes bracket and hardware for two 7AH or two 18AH batteries. Iso 9001 INwI1wc 111111111111111T SYSTIMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements All specifications are subject to change without notice NOTlylERAl and System Sensor® are registered trademarks at Honeywell International, Inc. Wheelock® is a registered trademark at Cooper Tech- nologies Company Gentvx® is a registered trademark of Genres Corpora- I]on AMSECO® is a reiatered trademark of Foyer Electric Signal 12 Clintonville Road Company, LLC ANSI® is registered trademark of the American National Northford, CT 06472 Standards Institute, Inc. 203.484.7161 ©2021 by Honeywell International Inc All tights reserved. Unauthorized use at this document is strictly prohibited www.notifier.com Country of Origin: USA NOTIFIER® by Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM NNX LISTING SERVICE LISTING No.: 7315-0028:0513 CATEGORY: 7315 - POWER UNITS LISTEE: Notifier One Fire-Lite Place, Northford, CT, 06472 Contact: Brant, Lisa (203) 484-6105 (203) 484-7309 Email: Iisa.branthoneywell.com DESIGN: Models PSE-6, PSE-6E, PSE-6R, PSE-lO, PSE710E, and PSE-1OR Power Supply Expander. Model ZNAC-PS Class A Converter Module. The PSE series are remote power supply and battery charger units which also provide programmable synchronized Class B NAC's. Model Variations: All PSE-6 Models: Maximum 6A Capacity; 5 Class B NAC's; 2 Command Inputs; Trouble and AC Loss Relays All PSE-lO Models: Maximum 1 O Capacity; 7 Class B NAC's; 3 Command Inputs; Trouble and AC Loss Relays With Suffix 'E": Nominal 240V, 50/60 Hz AC Input Without Suffix 'E": Nominal 120V, 50/60 Hz AC Input With Suffix "R": Red Enclosure Without Suffix "R': Black Enclosure Model ZNAC-PS: Optional Class A Conversion Module Refer to listees printed data sheet for detailed product description and operational considerations. RATING: Models PSE-6 and PSE-6R: 120V AC, 50/60 Hz, 5.OA Maximum Models PSE-6E: 240V AC, 50/60 Hz, 2.7A Maximum Models PSE-lO and PSE-IOR: 120V AC, 50/60 Hz, 6.2A Maximum Models PSE-10E: 240V AC, 50/60 Hz, 3.5A Maximum Model ZNAC-PS: 24V DC Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a power supply extender when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTES: 09-16-20 VWW Mr I This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational J requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/24/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 NOTIFIER by Honeywell' FSP-951 Series Addressable Photoelectric Smoke Detectors The NOTIFIER® FSP-951 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the FSP-851 Series. A new modern, sleek, con- temporary design and enhanced optical sensing chamber is engi- neered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The FSP-951 Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the FSP-951T. The FSP-951R is a remote test capable detector for use with DNR Series duct detector housings. FSP-951 series detec- tors are available for both FlashScan® and CLIP applications as designated. Features SLC LOOP: Two-wire SLC loop connection Unit uses base for wiring Compatible with FlashScan® and CLIP protocol systems Stable communication technique with noise immunity ADDRESSING: Addressable by device Rotary, decimal addressing (Refer to the NOTIFIER panel manuals for device capacity.) ARCHITECTURE: Sleek, low-profile, stylish design Unique single-source design to respond quickly and dependably to a broad range of fires Integral communications and built-in device-type identification Built-in tamper resistant feature Remote test feature from the panel Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only) Built-in functional test switch activated by external magnet Removable cover and insect-resistant screen for simple field cleaning Expanded color options OPERATION: Designed to meet UL 268 7th Edition Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level LED "blinks" when the unit is polled (communicating with the fire panel) and latches in alarm. Low standby current MECHANICALS: Sealed against back pressure SEMS screws for wiring of the separate base Designed for direct-surface or electrical-box mounting Plugs into separate base for ease of installation and maintenance Separate base allows interchange of photoelectric, ionization and thermal sensors OPTIONS: Optional relay, isolator, and sounder bases Installation FSP-951 Series plug-in intelligent smoke detectors use a detach- able base to simplify installation, service and maintenance. Installa- tion instructions are shipped with each detector. Mount detector base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 7-taps" or branches are permitted for Class "B" wiring only. When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and isola- tor bases. Construction These detectors are constructed of fire-resistant plastic. The FSP- 951 Series plug-in intelligent smoke detectors are designed to com- mercial standards and offer an attractive appearance. Operation Each FSP-951 Series detector uses one of the panel's addresses (total limit is panel dependent) on the NOTIFIER Signaling Line Cir- cuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The FSP-951 Series offers fea- tures and performance that represent the latest in smoke detector technology. Product Line Information NOTE: '-1V" suffix indicates CLIP and FlashS can device. FSP-951: White, low-profile intelligent photoelectric sensor, FlashS- can only FSP-951A: Same as FSP-951 but with ULC listing DN-60977:D • 8/13/2020 - Page 1 of 3 (FSP951-IV: Ivory, low-profile intelligent photoelectric sensor FSP-951A-IV: Same as FSP-951-IV but with ULC listing FSP-9511: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed-temperature thermal device, FlashScan only FSP-951TA: Same as FSP-951T but with ULC listing FSP-951T-IV: Ivory, same as FSP-951T but includes a built-in 135°F (57°C) fixed-temperature thermal device FSP-951TA-IV: Same as FSP-951T-IV but with ULC listing (FS95lR: White, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW, FlashScan only FSP-951 RA: Same as FSP-951 R but with ULC listing, for use with DNRA FSP-951 R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW FSP-951RA-IV: Same as FSP-951R-lV but with ULC listing, for use with DNRA INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300A-6: Same as B300-6, ULC listed B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-WHITE-BP: Bulk pack of B501 -WHITE contains 10 B224RB-WH: White, relay base (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base (CSFM: 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing B224RBA-IV: Ivory, relay base, ULC listing B224B1-WH: White, isolator detector base (CSFM: 7300-1653:0216) B224B1-IV: Ivory isolator detector base (CSFM: 7300-1653:0216) B224B1A-WH: White, isolator detector base, ULC listing 6224B1A-IV: Ivory isolator detector base, ULC listing B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200SA-WH: Same as B200S-WH, ULC listing B200SA-IV: Same as B200S-IV, ULC listing B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications Page 2 of 3— DN-60977:D • 8/13/2020 B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz i-/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653.-0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as B200SR-WH with, ULC listing B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base TR300•IV: Ivory, replacement flange for B21OLP(A) base RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B300-6(A). M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: Color Kit (includes cover and trim ring), white, 10-pack CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack SPECIFICATIONS Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0 (51 mm) high; base determines diameter - B300-6 series: 6.1 (15.6 cm) diameter - B501 series: 4° (10.2 cm) diameter For a complete list of detector bases see DN-60981 Shipping weight: 3.4 oz. (95 g) Operating temperature range: FSP-951 Series: 32°F to 122°F (0°C to 50°C) FSP-951T Series: 32°F to 100°F(0°C to 38°C) FSP-951R Series installed in DNR/DNRA/DNRW, -4°F to 158°F (-20°C to 70°C) ULJULC Listed Velocity Range: 0-4000 ft/mm. (1219.2 rn/mm.), suitable for installation in ducts Relative humidity: 10% - 93% non-condensing Thermal ratings: fixed-temperature set point 135°F (570C), rate-of- rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15- 32 volts DC peak Standby current (max. avg.): OpA@ 24 VD(one communica- tion every 5 seconds with LED enabled) Max current: ("ON") DETECTOR SPACING AND APPLICATIONS NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1 m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document SPAG91, is available at www.systemsensor.com. Listings and Approvals Listings and approvals below apply to the FSP-951 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listing: Sills FM Approved CSFM: 7272-0028:0503 NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com iso 000i ROMPS IBM I11' OUAIITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. FlashScart®. NOTIFIER®, and System Sensor® are registered trade- marks at Honeywell International, Inc. 50020 by Honeywell International Inc. All rights reserved. Unauthorized use at this document is strictly prohibited. Country of Origin: Mexico 0 NOTIFIER® by Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7272-0028:0503 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Notifier One Fire-Lite Place, Northford, CT, 06472 Contact: Brant, Lisa (203) 484-6105 (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Models FSP-951, FSP-951-SELFT, FSP-951R, FSP-951T, FSP-951T-ISO, NP-200, NP- 200R, and NP-200T analog addressable, photoelectric smoke detectors for open area and duct installations. Models FSP-951T, FSP-951T-SELFT, FSP-951T-ISO and NP- 200T have complementary heat detectors. All models are similar except for population/depopulation of components on the Printed Wiring Board for the intended features. *All models may be followed by a two digit suffix, indicating the color of the detector's enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed bases: Model B71OLP (CSFM No. 7300-0028:0173); System Sensor Models B224B1, B224RB (CSFM No. 7300-1653:0126); B200S, B200SR (CSFM No. 7300-1653:0213); B2005-LF, B200SR-LF (CSFM No. 7300-1653:0238); B501, B21OLP, B300-6, B300-6-IS (CSFM No. 7300-1653:0109). System Sensor duct detector housings Models DNR and DNRW (CSFM No. 3240-1653:0209) and separately listed compatible fire alarm control units. The Models FSP-951-SELFT and FSP-951T-SELFT are not Listed for use in duct environments. Refer to manufacturer's Installation Manual for details. All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition. Pagel of 2 ,.., CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. *Revision 10-10- 22 VWW This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/21/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 NOTIFIER® by Honeywell DNR(A) and DNRW Intelligent Photoelectric Duct Detectors The Notifier DNR(A) intelligent non-relay photoelectric duct smoke detector and DNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectan- gular footprints capable of mounting to a round or rectangular duct. The DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against fall- ing dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, oper- ating in airflow speeds of 100 to 4,000 feet per minute (0.5-20.32 m/s), temperatures of -4°F - 158°F (-20°C - 70°C), and a humidity range of 0-95 percent (non-condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indicates a trouble sig- nal for a removed or improperly installed sensor cover. The housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module. The Notifier DNR(A) duct smoke detectors can be customized to meet local codes and specifications without additional wiring and are compatible with all previous models, including remote test accesso- ries. Features Photoelectric, integrated low-flow technology Air velocity rating from 100 ft/mm —4,000 ft/mm (0.5 m/s —20.32 m/s) Versatile mounting options: square or rectangular configuration Broad ranges for operating temperature (-4°F - 158°F, -20°C - 70°C) and humidity (0% - 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required Cover tamper signal Increased wiring space with a newly added 3/4" conduit knockout Available space within housing to accommodate mounting of a relay module Easily accessible code wheels on sensor head (sold separately) Clear cover for convenient visual inspection Remote testing capability Requires com line power only Accommodates an addressable relay module, sold separately, (FRM-1) for applications requiring a Form-C relay Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depth Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Operating Temperature Range: -4°F - 158°F (-20°C - 70°C) Storage Temperature Range: -22°F - 158°F (-30°C - 70°C) Operating Humidity Range: 0% - 95% relative humidity (non-con- densing) Air Duct Velocity: 100 —4,000 ft/mm (0.5— 20.32 m/s) Accessories Notifier provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. DNR(W) housings with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote-test-capable detector. ACCESSORY CURRENT LOADS AT 24 VDC Device Standby Alarm RA100Z OmA 12mA Max RTS151/RTS151KEY OmA 12mA Max Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest list- ing status. UL: S635, S3705 ULC:S635 CSFM: 3240-1653:0209 FM approved Product Line Information NOTE: 'A suffix indicates ULC listed model. DNR(A): Intelligent non-relay photoelectric low flow smoke detector housing. Requires photoelectric smoke detector (sold separately). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector (sold separately). NEMA-4 rated. FSP-951 R(A)-IV: Remote test capable addressable low-profile pho- toelectric smoke detector; ivory; supports CLIP and FlashScan® protocols FSP-951R(A): Remote test capable addressable low-profile photo- electric smoke detector; white; supports FlashScan protocol only FSP-951(A)-IV: Addressable low-profile photoelectric smoke detec- tor; ivory; supports CLIP and FlashScan protocols FSP-951R(A): Addressable low-profile photoelectric smoke detec- tor; white; supports FlashScan protocol only DCOlL: Remote test coil. Required for older DNR(W) duct detector housing DUCTCOV: Retrofit DNR cover for manufactured prior to April 2014 ON-60429:C2 • 11/7/2019—Page 1 of 2 DUCTCOVW: Retrofit DNRW cover for manufactured prior to April 2014 DSTI(A): Metal sampling tube duct width up to 1 ft (0.3m) DSTI.5(A): Metal sampling tube duct widths up to 1 ft —2 ft (0.3- 0.6 m) DST3(A): Metal sampling tube duct widths up to 2 ft —4 ft (0.6 - 1.2 M) DST5(A): Metal sampling tube duct widths up to 4 ft - 8 ft (1.2 —2.4 M) DSTIO(A): Metal sampling tube duct widths up to 8 ft - 12 ft (2.4 - 3.7 m) DH4000E-1: Weatherproof enclosure ETX: Metal exhaust tube duct, width 1 ft (0.3 m) M02-04-00: Test magnet P48-21-00: End cap for metal sampling tubes RAIOOZ(A): Remote annunciator alarm LED RTSI5I(A): Remote test station RTSI5IKEY(A): Remote test station with key lock Important Notes DNR(W) duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. DNR(W) duct detector housings with a date code of 0012 or ear- lier require a DCOIL and auxiliary 24 VDC power for remote test applications. Iso 9001 I auaIuTY sf511.1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot coven all specific applications or anticipate all requirements. All specifications are Subject to change without notice. NOTIFIER 12 Clintonville Road Notiher® and FlashScanO are a registered trademark of Honeywell nte- national Inc. Northford, CT 06472 520th by Honeywell International Inc. All rights reserved. Unauthorized 203.484.7161 use of this document is strictly prohibited. www.notifier.com Country of Origin: Mexico NOTIFI ER® by Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 3240-1653:0209 CATEGORY: 3240 - DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc. 3825 Ohio Ave, St. Charles, IL, 60174 Contact: Brant,Lisa (203) 484-6105 (203) 484-7309 Email: lisa.branthoneywell.com DESIGN: Models DNR, DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTES: 01-02-18 gt This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/21/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 1 of 1 DN-6724:B3 FCM-1(A) & FRM-1(A) NOTI Fl ER® Series (a Control and Relay Modules by Honeywell Intelligent iAddressable Devicesr General FCM-1(A) Control Module: The FCM-1 (A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1 (A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1(A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1 (A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM-1 (A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 - 99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1(A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScanO releasing applications. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01-159). J7 II 111 E(PWR.) • L 1151(0 (O'1W TIG EST PYlE(S) OLE (-P TI 'enc. fit FCM-1 (A) The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1 (A) provides two Form-C dry contacts that switch together. Operation Each FCM-1 (A) or FRM-1 (A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1 (A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1 (A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM-1(A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) DN-6724:B3.17/2O11—Page 1 of 2 Maximum NAC Line Loss: 4 VDC. Contact Ratings for FRM.1 (A) External supply voltage (between Terminals T10 and Til): Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM.1(A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: T'A(LED on). Average operating current: (pAdirect poll; 255 pA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C) Humidity range: 10% to 93% non-condensing. Dimensions: 4.5' (114.3 mm) high x 4 (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125° (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S3705 (A version only) FM Approved CSFM: 7300-0028:0219 MEA: 14-00-E FDNY: COA #6067, #6065 Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded .5A 30 VDC Inductive (LlR5ms) Coded 1 A 30 VDC Inductive Coded (LIR=2ms) .3A 125 VAC Inductive Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: "A" suffix indicates ULC Listed model. FCM-1(A): Intelligent Addressable Control Module. FRM-1(A): Intelligent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1(A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document 156-1169. FRM-1(A) Installation document 156-3502. Notifier SLC Wiring Manual, document 51253. Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so ooi We try to keep our product information up-to-date and accurate. . . We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S,A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2- DN-6724:133 • 2/17/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7300-0028:0219 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Notifier One Fire-Lite Place, Northford, CT, 06472 Contact: Brant, Lisa (203) 484-6105 (203) 484-7309 Email: lisa.branthoneyweII.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM- 1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM..1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTES: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational ;,;;c.4 requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/21/2023 Listing Expires: 06/30/2024 Page 1 of 2 :.;. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL k-J1I FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Page 2 of 2 SYSTEM $ SENSOR® Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the [-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING APPROVED 0 USTED S5512 FM approved eecepf 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057363 AVDS868-02 • 13501/2317 • Page 3 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuite Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor [-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor [-Series Model listed to U[ 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor [-Series Model ______ listed to U[ 1971 and U[ 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MD[3 listed to U[ 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/RNR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 Cd. AVDS868-02 • 12/0112017 • Page 2 UL Current Draw Data 8-17.5 Volts 16-33 Volts Candela DC DC FWR Candela 15 87 41) 60 Range 30 153 "63,E 86 75 N/A (iii) 142 95 N/A (134 164 115 N/A (158 191 150 N/A (189 228 177 N/A 226 264 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 UL Max. Current Draw (mA DC Input RMS), Ceiling 8-17.5 Volts 15cd Horn Strobe, 30cd Candela 16-33 Volts 15cd 3.1 KHz Non-Temporal Low Coded High 3.1 KHz Coded High Range (15-177 cd) 30cd 75cd 95cd 28 43 42 11 5c 29 47 43 150cd 54 54 54 177cd Temporal High 103 167 (7t 1, 90 (143 (165 (187 12171 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound OutDut Data 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868.02 • 12/01/2017 • Page 3 2.47"(62.7 mm) 1.37 (34.8 mm) di--- (173n 6.92 rlism (175. (64 mm) L-Series Dimensions A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box .01 1-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe, Red (PC2WL 2-Wire, Horn Strobe, White (SCWL1 Strobe, White PC4RL 4-Wire, Horn Strobe, Red SCWL-CLR-ALERT Strobe, White, ALERT PC4WL 4-Wire, Horn Strobe, White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications". STEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2017 System Sensor. SENSOR Phone: 800-SENSOR2 e Fax: Product specifications subject to chanye without notice. Visit systernsensor.com for current product ntorora5on, ncludrng neatest uersrnrr of this data sheet. 630-377-6495 AVDS868.02 • t2/ot/2017 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7125-1653:0504 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc. 3825 Ohio Ave, St. Charles, IL, 60174 Contact: Brant,Lisa (203) 484-6105 (203) 484-7309 Email: lisa. bra nthoneyweIl.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WailTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION 'A OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 1 SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDCIfwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for NOTES: *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational 'JI requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/21/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2of2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7125-1653:0517 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc. 3825 Ohio Ave, St. Charles, IL, 60174 Contact: Brant,Lisa (203) 484-6105 (203) 484-7309 Email: lisa.branthoneywell.com DESIGN: Models P2RL-LF and P2WL-LF are low frequency *wall horn/strobes. *Models PC2RL-LF and PC2WL- LF are low frequency ceiling horns/strobes. For these models, the horn has a 6 position selectable tone settings. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, date of manufacturer, model number, electrical ratings, audibility ratings, and UL label. APPROVAL: Listed as horn/strobes when used with separately listed compatible fire alarm control units. For indoor dry use. Operating Temperature Range: 0°C to 49°C (32°F to 120°F). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. NOTES: *Revision 08-28-20 vww I: This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/21/2023 Listing Expires: 06/30/2024 Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL k-1AI FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2of2