Loading...
HomeMy WebLinkAbout7100 AVIARA RESORT DR; ; FPC2020-006611i L1] : I (7city of Carlsbad . fJJjjj . Print Date: 07/22/2024 Permit No: FPC2020-0066 Job Address: 7100 AVIARA RESORT DR, CARLSBAD, CA 92011-4908 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2157500100 Track : Applied: 04/07/2020 Valuation: $1,299,954.50 Lot #: Issued: 04/20/2020 Occupancy Group: Project #: DEV89028 Finaled Close Out: 08/28/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check#: INSPECTOR: Maldonado, Adalmira Plan Check 4*: Salcedo, Felix Project Title: PACIFIC RIM Description: PARK HYATT AVIARA -SPRINKLER TI (194 HEADS) Applicant: FPContractor: DESIGN BUILD FIRE PROTECTION INC DESIGN BUILD FIRE PROTECTION INC ROBERT BERRY 13771 DANIELSON ST, # SUITE G 13771 DANIELSON ST POWAY, CA 92064-8840 POWAY, CA 92064-6896 (858) 842-3237 (858) 842-3237 FEE AMOUNT FIRE Hourly Services First Hour $159.00 FIRE NFPA 13 or 13R System > 100 heads $654.00 Total Fees: $813.00 Total Payments To Date: $813.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov D DESIGN BUILD }_)J FIRE PROTECTION, INC. C-16 License #926322 13771 Danielson Street, Suite G - Poway, CA 92064 Phone (858) 842-3237 - Fax (858) 842-3226 DATE: 10-6-2017 PROJECT: Park Hyatt Carlsbad, CA GENERAL CONTRACTOR: PSI FIRE SPRINKLER MATERIAL SUBMITTAL item Page Fire Sprinklers '1 Concealed Pendent 1 Recessed Pendent 8 Upright Sprinkler 8 Dry Barrell Sprinkler 15 Page 1 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT III(IIs1G® SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile cover assembly that provides up to 1/2" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE ([NT) coating has been investigated for installation in corrosive environments and is cULus Listed as indicated in the Approval Charts. The [NT finish is only available for the sprinkler assembly, the cover plate is not plated. LISTINGS AND APPROVALS cus cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 WARNING: Cancer and Reproductive Harm- -. wwwP65Warnings.ca.gov VdS Approved: Certificate G4080021 LPCB Approved: Certificate number 096e/12 (E CE Certified: Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate 0832-MED-1003 Refer to Approval Chart 1 Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Form No. F_103005 18.10.11 Rev 18.2.P65 Replaces Form No. F_103005 Rev 18.2 (Added P65 Warning.) Page 2 of 7 MIRAGE® STANDARD AND '4 I F(IF'IG QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C11000 or Stainless Steel UNS-S30400 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirages Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463 - HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 "F (68 "C) = B, 175 "F (79 "C) = D, 200 "F (93 "C) = E For example, sprinkler VK463 with a 155 "F (68 "C) temperature rating = 13667AB. Standard Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135 "F (57 "C) UL (139 °F (59 "C) FM and LPCB) = A, 165 "F (74 "C) = C For example, cover 13504 with a Polished Chrome finish and a 165 °F (74 °C) temperature rating = 13504FC. Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Temperature Suffix: 135 "F (57 "C) UL (139°F (59 "C) FM and LPCB)=A, 165 "F (74 "C) = C For example, cover 21876 with a 165 "F (74 "C) temperature rating = 21876C NOTE: The cULus Listings for the square cover plate 15394 are for the 135°F (57 "C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a 1/2 ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_103005 18.10.11 Rev 18.2.P65 All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers CUS. (fl \\ 'silkiNG I set iA.lst T -, 4 3-5/16" (84 mm) Figure 2: Square Cover Assembly 15394 Page 3 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP N41KJWJ SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1SPRINKLER TEMPERATUREIl[e.'PAND1llFINISHES I Sprinkler ikle S r Cover Plate Large Cover Squire Cover M*WÜ Temperature Nominal -- -= Ambient - Temperature Rating of Cover Base Part Plate Base Part Plate Base Part Bulb Color Classification Temperature Ceiling - Assembly (Required) Number Number Number Rating' Temperature,' 135 °F (57 °C) cULus Ordinary 155 °F (68° C) 100 °F (38 °C) 13504 or 21876 13642or218751 15394 Red 139 °F_(59_°C)_FM and_LPCB Intermediate 175 °F (79° C) 150 °F (65° C) 165 °F (74 °C) 13504 or 218761 113642 or 2187551 15394 Yellow Intermediate 1 200°F (93° C) 150°F (65° C) 165°F (74 °C) 13504 or 2l876 13642 or 21875 15394 Green Cover Plate Finishes': Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Sprinkler Finishes: Brass and ENT Corrosion Resistant Coatings': ENT Footnotes The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 4 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. Stainless Steel versions are not available with any finishes or paint. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 4 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 7- ~7 1(UL) Sprinilder Temperature Rating -f Covet ~131e Ternperature Rating Mira ge Concealed Peiident Sprinklers VK462 and VK463 AWII- Cover aLF rlists KEY Thread Nominal Maximum Listings and Approvals4 Sprinkler SIN Size K-Factor Water Working (Refer also to Design Criteria) Base Part No.' Pressure Inch mm U.S. meti1c2 cULus' NYC I VdS7 LPCB CE 12 Standard Response Applications 13503A VK462 1/2" - 5.6 80.6 175 psi (12 bar) -- - AY1CZ1 AY1,BZ1 AY1,CZ18 AY3 - 19785A VK462 112" - 5.6 80.6 175 psi (12 bar) -- - - - -- - AY2,CZ2 21356A VK462 -- 15 5.6 80.6 175 psi (12 bar) -- - - - -- - AY2, CZ2 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1,AV1, BX16 - - - AY3 -- 13503JN11 VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BXI,AV1, BX16 - - -- - -- __________ AS3, BT3 13667A VK463 1/2" 15 5.6 80.6 250 psi (17.2 bar)3 AV1, BX1 AV1, BX16 - - -- - -- Cover Plate Assembly Temperature Ratings',' Sprinkler Temperature S - 135 "F (57 "C) cover 21876 or 21875 (large diameter) Cover Plate Assembly Finishes10 Ratings T - 165 °F (74 °C) cover 21876 or 21875 (large diameter) 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique A- 155 F (68 V - 135 F (57 C) cULus Listed cover 13504, 13642 (large diameter), or 15394 (square cover plate) Brass, Brushed Brass, Brushed Copper, Painted White, B - 175 F (79 C) and 200 F x - 165 °F (74 "C) cover 13504, or 13642 (large diameter) Painted Ivory, or Painted Black (93 C) Y - 135 "F (57 "C) cover 13504 LPCB Approved as 139 "F 2 - Brass C - 200 "F (93 °C) (59 "C) 3 - Stainless Steel Z - 165 "F (74 "C) cover 13504 Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. 7 VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 +A1:2001 i-A.2:2004 +A3:2006, Certificate G4080021. 10E Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD40249. The 135/139 °F cover has an orange label. The 165 "F (74 °C) cover has a white label. 10 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 11 cULus Listed as corrosion resistant. 12 MED Certified, Standard 12259-1, EC-certificate 0832-MED-1003. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No. F_I 03005 18.10.11 Rev 18.2.P65 Page 5 of 7 M I RAG EO STANDARD AND N4 I KJ QR CONCEALED PENDENT SPRINKLER VK462 AND HP 0 SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com - DESIGN CRITERIA. UL - (AlSo refer t-A-pr cULus Listing Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Approval Requirements: The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupan- cies, except in 0H4. NOTES: Due to the design the sprinkler type 'Domed-CCP' shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: Prepare the sprinkler key. Remove the plastic cover. Hold the sprinkler with the wrench and fasten it. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F103005 18.10.11 Rev 18.2.P65 Page 6 of 7 MIRAGE® STANDARD AND 4J II(IF4r1G®QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 2694118-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com ApproáI Chart 2 (FM) Cover Plate TerripeFature Rati Mirage5 Standard ResponLe Concealed Pendent Sprinkler VK462 AW1* Cover Plate Fin_KEY Sprinkler Base NPT Thread Size Nominal K-Factor Maximum FM Approvals3 Part No.' SIN Water Working (Refer also to Design Criteria below.) Inch mm U.S. mett1c2 Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AWl, BX1,AY2, BZ2 Cover Plate Assembly Temperature Ratings1'4 Cover Plate Assembly Finishes5 Sprinkler Temperature Ratings Y - 139 OF (59 "C) cover 21875 or 21876 z - 165 OF (74 °C) cover 21875 or 21876 1 - Polished Chrome, Brushed Chrome, Bright A- 155°F (68 °C) W- 139°F (59 °C) cover 13504, 13642 (large diameter), or Brass, Antique Brass, Brushed Brass, B -175°F (79 °C) and 200°F (93 °C) 15394 (square cover plate) Brushed Copper, Painted White, Painted X - 165 OF (74 °C) cover 13504, 13642 (large diameter), or Ivory, or Painted Black 15394 (square cover plate) 2 - Stainless Steel Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. The 139 OF (59 °C) cover has an orange label. The 165 OF (74 °C) cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA wfW - - (Also refer töApproval Chart 2 above) - - FM ADoroval Requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F103005 18.10.11 Rev 18.2.P65 Sprinkler Wrench Part No. I4047WB** Sprinkler and Adapter Assembly Protective cap removed Use wrench 14O47WB Step 1: Carefully slide the wrench sideways around the deflector and pins Step 2: t Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. 2-1/4" (57 mm) diameter opening required in the ceiling. Page 7 of 7 MIRAGE® STANDARD AND OR CONCEALED PENDENT "4J II(IIr1G® SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047WB** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise Ito 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Sprinkler frame arms Sprinkler wrench fla - 112"(I5 mm) NPT 29/ Maximum 1665*. 2-1/16" (52 mm) Minimum CI'C) -tji1 i1Ii 2-3/4" (70 mm) or NOTE: Upon sprinkler activation, the deflector descends 3-5/16'(84 mm) to approximately 13/16" (21 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F-1 03005 18.10.11 Rev 18.2.P65 Replaces Form No. F_103005 Rev 18.2 (Added P65 Warning.) Page 1 of 6 MICROFAST® QUICK 4J I Ki RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast Quick Response Pendent Sprinkler VK302 is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. LISTINGS AND APPROVALS cULus Listed: Category VNlV FM Approved: Class Series 2000 VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 LPCB Approved: Certificate 096e106 WARNING: Cancer and Reproductive Harm- w.wP65Wamingscagov CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-50021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 C) = A, 155 ¶ (68 C) = B, 175 °F (79 C) = D, 200 ¶ (93 °C) = E, 286 F (141 00) = G Form No. F_033314 19.02.21 Rev 19.1 Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-i Escutcheon.) Page 2 of 6 MICROFAST® QUICK 'J I I(IIs1G® lII[s1U'7W.. RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 2F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2 ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap- Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F033314 19.02.21 Rev 19.1 Sprinkler wrench 13655W/B* for recessed pendent sprinklers **A 1/2" ratchet is required (not available from Viking) Page 3 of 6 r1G® RESPONSE PENDENT Ki SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES - -_----=.- = :=--L-----•- -- - -I Sprinkler Temperature Sprinkler Nominal --- '--ri- Maximum Ambient i- Classification Temperature Rating Ceiling Temperature Bulb Color U o Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F033314 19.02.21 Rev 19.1 Page 4 of 6 IIs1G®MICROFAST@ QUICK RESPONSE PENDENT Ki SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com ApproväICharti"(UL) The Viking Microfast® Quick Response KEY Finish Pendent Sprinkler VK302 Ffix i cffappscabie) Maximum175PSI(12Bár)WWP - Base Sprinkler Thread Size Nominal Overall Listings and Approvals' Part SIN Style K-Factor Length (Refer also to Design Criteria.) Criteria.) NPT Number' BSP U.S. metric' Inches mm cULus' VdS LPCB (E 8 12979 VK302 Pendent 1/2 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, B1Y D1Z, dY Dl 19780 VK302 Pendent 1/2" - 5.6 80.6 2-1/4 58 - - - -- -- D3 21354 VK302 Pendent - 15mm 5.6 80.6 2-1/4 58 - - - -- -- D3 - Product Below lability (Contact Local Viking Office) 06662B VK302 Pendent 1/2" 15 min 1 5.6 80.6 F 2-1/4 58 A1Z, B1Y, D2, C2X -- - -- -- 18021 VK302 I Pendent 1 1/2" 15mm1 5.6 80.6 1 2-1/4 58 AiX, B1Y Al I AiX, B1Y D1X, Cir Di - Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135 "F (57 CC), 155 "F (68 CC), 175 "F I - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 "C), 200 "F (93 °C), 286 °F (141 °C) Polyester56, Black Polyes- Viking Micromatic® Model E-1 Recessed Escutcheon B - 135 F (57 "C), 155 "F (68 "C), 175 "F ter -' Y - Standard surface-mounted escutcheon or recessed with the Viking Micromatic® (79 "C), and 200 "F (93 "C) 2 - ENT5 Model E-i, E-2, or E-3 Recessed Escutcheon C - 155 "F (68 "C), 175 "F (79 "C), and 3- Chrome Z - Standard surface-mounted escutcheon 200 "F (93 "C) D - 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), 286 "F (141 "C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, Ed-certificate of constancy of performance 0832-CPR-S0021. 8 MED Certified, Standard EN 12259-1, EC-0832-MED-1003. -- . -.. ...- - DESIGN CRITERIA - UL - (Also refer to AppThval Chart Al above) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F033314 19.02.21 Rev 19.1 Page 5 of 6 l'III['1iUu7f M PONSE PENDENT JII(IFr41Gj® RES ICROFAST®QUICK SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Ch 2 (M The Viking Microfast5 Quick Response F1nsh I - - MX Escutcheon (if pp Pendent Sprinkler VK302 - -Maximum175PSl(l2 Bar) WWP - Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric2 Inches mm 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 1 58 A1Z, B1Y, D2X, C2 frJj• ProductJ:f Limited Availability (ContactI 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 1 58 A1Z, B1Y Approved Temperature Ratings Approved Escutcheons A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200 °F X - Standard surface-mounted escutcheon or the (93 °C), 286 °F (141 °C) Approved Finishes Viking Micromatic5 Model E-1 Recessed B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 1 -Brass, Chrome, White Polyester', Escutcheon 200 °F (93 °C) and Black Polyester4 Y - Standard surface-mounted escutcheon or recessed C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2 - ENT5 with the Viking Micromatic® Model E-1 or E-2 °F (141 °C) Recessed Escutcheon 0 - 155°F (68 °C), 175 °F (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion proofing for corrosive environments. DESIGN CRITERIA FM .- Z (Also reftApprol Chart 2 böve) - FM Approval Requirements: The Viking Microfast®1 Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.02.21 Rev 19.1 1-1/8" (29 mm) Mm. 7 1-1/8" (29 mm) Mm. 2" (51 mm) -:r Max. Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum Page 6 of 6 tJ I I(IIs16i®MICROFAST" QUICK RESPONSE PENDENT S PRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2-5/16" (59 mm) minimum (15 mm) -J 2-1/2" (64 mm) maximum NPT : I •:, ,.• - L_.._ (57 mm (45 mm) - mt Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon :1 2-1/8' —ø j(54 mm) A 1-3/4" it J (45 mm) ir44 Max. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 19.02.21 Rev 19.1 Replaces Form No. F_033314 Rev 18.1 P65 (Removed F-i Escutcheon.) Page 1 of 7 4sJ KiI16i® STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page. DESCRIPTION Viking Standard Response Dry Pendent Sprinklers are thermosensitive spray sprin- klers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction systems where it is necessary to prevent water or conden- sation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Standard Response Dry Pendent Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive environments and are listed/approved as indicated in the approval charts. NOTE: When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indi- cation of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Classes 2013 and 2015 NYC Approved: MEA 89-92-E, Volume 37 zt WARNING: cancer and Reproductive Harm- ww.P65wamings.ca.gov FCB) LPCB Approved: Ref. No. 096e/06 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPR-50021 MED Certified: Standard EN 12259-1, EC-certificate 0832-MED-1 003 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) NOTE: Other International approval certificates are available upon request. Refer to Approval Chart I and Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1991. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to 100 psi (6.89 bar) Thread size: 1" NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) for all listed and approved lengths. Glass-bulb fluid temperature rated to -65 ¶ (-55 C) Covered by the following U.S. Patents: 8,636,075 and 10,220,231 * cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). **Metric K-factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Form No. F_071591 19.06.24 Rev 19.1 Replaces Form No. F_071591 Rev 18.1.P65 (Added patent number.) Page 2 of 7 STANDARD RESPONSE A l*I:II[sU.7fA DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Pip Cap: Brass UNS-C31400 or UNS-C3 1600 Pip Cap Adapter: Brass UNS-C36000 Seat (for Sprinklers VKI51, VK155, and VK159 only): Copper UNS-C21000 Orifice: Copper UNS-C22000 or UNS-C11000 (Copper UNS-C21000 for Sprinklers VK151, VK155, and VK159) Gasket (for Sprinklers VK151, VK155, and VK1 59 only): Buna-N Tube: ERW Hydraulic Steel Tube Barrel End and Threads (for Sprinklers VK150, VK154, and VK158): QM Brass Support (Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Order Standard Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ("A" dimension) to sprinkler base part number. Order in a specific length noted as the 'A" dimension (see Figures 3 through 5). The "A" dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 1-1/2" to 45-1/2" (38.1 to 1,156 mm) for the adjustable standard style, 3" to 47" (76.2 to 1,194 mm) for the plain barrel style, and 3-1/4" to 47-1/2" (82.5 to 1,207 mm) for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a "made-to-order" basis: Recessed Dry Pendent up to 65-1/2" (1,664 mm). Adjustable Standard Dry Pendent up to 63-1/2" (1,613 mm). Plain Barrel Dry Pendent up to 65" (1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, and ENT = JN Temperature Suffix (°F/°C): 155"/68" = B, 175"/79° = D, 200"/93" = E, 286"/141" = G For example, sprinkler VK154 with 1" NPT Threads, a Chrome finish and a 155 "F/68 "C temperature rating, and "A" length of 10" = Part No. 07740UFB10. Available Finishes And Temperature Ratings: Refer to Table 1. Wrench Accessories: (Also refer to the Viking website.) Hat Protective Sprinkler Wrenches: Sprinkler Standard Wrench: Part No. 07297W/B (available since 1991) Shield Wrench for recessed sprinklers: Part No. 07565W/Bt (available since 1991) tA 1/2 ratchet is required (not available from Viking). Sprinkler Guard: Chrome, with no listings or approvals, for installation on dry pendent sprinklers manufactured after May 1994 only (Part No. 08954). Replacement Escutcheons: Adjustable Standard Dry Escutcheon: Base Part No. 07741 Recessed Dry Escutcheon Cup: Base Part No. 05459A Go7297Q INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION Figure 1: Standard Sprinkler Wrench 07297W/B During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. Form No. F_071591 19.06.24 Rev 19.1 Page 3 of 7 "J I I(IF1G® STANDARD RESPONSE l.I:II[.1uu7fA DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page. AVAILABILITY The Viking Standard Response Dry Pendent Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Noniñal Maximum Ambeñt Classification Temperature Rating' Ceiling Temperature' U lb Color Ordinary 155 °F (68 'C) 100 °F (38 °C) Red Intermediate 175 'F (79 'C) 150 'F (65 'C) Yellow Intermediate 200 'F (93 °C) 150 'F (65 'C) Green High 286 'F (141 'C) 225 'F (107 'C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coating',": White Polyester and ENT in all temperature ratings Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT cor- rosion proof. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environ- ment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. U . fl /—Wrench 07565V/Bi* mustbe used for installing recessed Y sprinklers Step 1: Carefully - slide the wrench *A 1/2' ratchet is required (not sideways around the ' .. the sprinkler deflector available from Viking). Step 2 Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers Form No. F071591 19.06.24 Rev 19.1 Page 4 of 7 I II(II1G ® STANDARD RESPONSE lsI:II[iu.yy DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. /ApprovaI Gh°art,1 (UL) 1 F T InIsh Standard'Response Standard Orifice Dry Pendent Sprinklers Esajttheon (rf applicable) Maximum 175 PSI P2 bar) WWP - -- - Sprinkler Nominal Order Length Listings and Approvals4 Base SIN Style Thread Size K-Factor2 Increment (Refer also to Design Criteria below.) Part No.' NPT BSP U.S. metric3 Inches mm cULus' NYC6 © LPCB (E7 08 07740U VK154 - Standard " - 5.6 -- 1/2" 12.7 Al, A6 Al - -- - 07854U 25 mm - Adjustable -- 80.6 1/2" 12.7 Al, A6 -- -- - -- -- 09341 VK155 - 25 mm - 80.6 1/2" 12.7 - - -- A2 A2 A2 06530U VK158 Adjustable Recessed 1" -- 5.6 -- 1/4" 6.35 B3, 67 63 - - - - 07853U - 25 mm - 80.6 1/4" 6.35 63, B7 - - - - - 20239U 1" - 5.6 - 1/4" 6.35 - - C9 -- - - 20374U -- 25 mm -- 80.6 1/4" 6.35 - - C9 -- - - 09342 VK159 - 25 mm -- 80.6 1/4" 6.35 -- -- - 63 63 B3 07852U Plain1" Barrel - 5.6 - 1/2" 12.7 A4, A8 AS -- - -- -- 07855U - 25 mm - 80.6 1/2" 12.7 A4, A8 -- -- - -- -- 09343 VK151 - 25 mm - 80.6 1/2" 12.7 - - - - AS AS I AS Approved Finishes and "A" Dimensions 1 - Chrome or White Polyester9 sprinkler with a Chrome or White Polyester Sleeve and Approved Temperature Ratings Escutcheon with "A" dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) "A" 2- Chrome with dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) A - 155 °F (68 °C), 175 °F (79°C), 200 °F (93 °C), 3-Chrome or White Polyester" with "A" dimensions 3-1/4" to 47-1/2" (82.5 to 1,207 mm) d °F hAl °C' an / 4-Chrome, White Polyester", or Brass with "A" dimensions 3" to 47" (76.2 to 1,194 mm) "A" 5-Chrome or Brass with dimensions 3" to 47" (76.2 mm to 1,194 mm) B - 155 °F (68 °C), 175 °F (79°C), and 200 °F (93 °C) 6 - ENT9 sprinkler with an ENT6 Sleeve and Escutcheon with "A" dimensions 1-1/2" to 45-1/2" C - 155 °F (68 °C) (38.1 mm to 1,156 mm) 7 - ENT9 with "A" dimensions 3-1/4" to 47-1/2" (82.5 to 1,207 mm) with "A" dimensions 3" to 47" (76.2 to 1,194 mm) Chrome with "A" dimensions 3-1/4" to 47-1/2" (82.5 to 1,207 mm) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 37. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPR-S0021. 6 MED Certified, Standard EN 12259-1, EC-certificate 0832-MED-1003. cULus Listed as corrosion resistant. -DESlGNCRiTERlk-UL ° (Also r6fer to Approval Chart 1 above) - NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-Bl tees. When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Requirements: Standard Dry Pendent Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray pendent sprinklers. Designed for use in Light, Ordinary, and Extra Hazard occupancies. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Locate no less than 4" (102 mm) from walls. Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured per- pendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F071591 19.06.24 Rev 19.1 - 13/16" (20,6 mm) Finished - Ceiling 1-1/2' - (38.1 mm) diameter 4-7/16' Sleeve finish (112.7 mm) matches Maximum escutcheon II - Minimum ceiling opening M'mum diameter' 1-3/4" (44.5 mm). Maximum ceiling hole 2-1/4' (C7 nn' (77.8 mm) 'H 'I' A For "A' Dimension Determine the distance from the face of the tee to finished ceiling. Round to the nearest 1/4' (6,35 mm) between 3-1/4" (82.5 mm) and 47-1/2' (1,219 mm). NOTE: The sprinkler will be recessed approximately 5/16' (7.9 mm) above the Finished ceiling with 5/8' (15.8 mm) vertical adjust- ment available, inished ceiling Minimum openin 2-1/8" diem Maximur openin 2-1/2' diam Adjuetmen 5/16" <7.9 mm) Minimum: 1" (25.4 r Maximum 1-5/8" (42.1 Figure 4: Adjustable Recessed Dry Pendent Sprinkler Page 5 of 7 '\J I I(II,1G® STANDARD RESPONSE l*I:II[.nu.7vA DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. For "A' Dimension' 1. Determine the distance from the face of the tee to the finished ceiling. 2. Round to the nearest 1/2" (12.7 mm) between 1-1/2' and 45-1/2' (38.1 mm and 1,156 mm). NOTE' The deflector will be located approximately 3-7/16' (87.3 mm) below the ceiling. with 1" (25.4 mm) upward and 1" (25.4 mm) downward adjustment. Deflector at minimum distance below ceiling. NOTE To locate the deflector at the minimum distance below the ceiling, with no upward adjustment available, order the dry pendent sprinkler 1" (25.4 mm) shorter than the A dimension. NOTE' To locate the deflector at the maximum distance below the ceiling, with no downward adjustment available, order the dry pendent sprinkler 1" (25.4 mm) Longer than the A dimension. Deflector at maximum distance below ceiling. Figure 3: Adjustable Standard Dry Pendent Sprinkler 6 'fl A Outside For "A" Dimension: diameter: 1-5/16' Determine distance (33.4 mm) from face of the (same as 1' tee to the base (25 mm) of the sprinkler. Schedule Round up to next 40 pipe). higher 1/2' (12.7 mm) increment between 3' (76.2 mm) and 47' (1,194 mm). T(4813/8m'M) Figure 5: Plain Barrel Dry Pendent Sprinkler Form No. F_071591 19.06.24 Rev 19.1 Page 6 of 7 "J II(II%1G® STANDARD RESPONSE DRY PEN DENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. ApprovaihartTFM) Tempey Standaid Response Standard Orifice Dry Pendent Sprinklers Finish - - - Maximum 175 PSI (12 bar) WWP - - - Sprinkler Thread Size Nominal K-Factor2 Order Length Increment FM Approvals' Base Part No." SIN Style y e (Refer also to Design Criteria below.) NPT BSP U.S. metric' Inches mm 07740U VK154 Adjustable Standard 1" 5.6 -- 1/2" 12.7 Al 07854U - 25 mm - 80.6 1/2" 12.7 Al 06530U VK158 Adjustable Recessed 1" -- 5.6 -- 1/4" 6.35 B2 07853U - 25 mm - 80.6 1/4" 6.35 B2 07852U VK150 Plain Barrel 1" - 5.6 -- 1/2" 12.7 A3 07855U - 25 mm - 80.6 1/2" 12.7 A3 Approved Temperature Ratings Approved Finishes and "A" Dimensions A - 155 °F (68 °C) 175 °F (79°C) 200 °F (93 °C) and 1 - Brass, Chrome, White Polyester, or ENT' sprinkler with a Brass, Chrome, White Polyester, or , ' 286 °F '141 ENT' Sleeve and Escutcheon with "A" dimensions 1-1/2" to 45-1/2" (38.1 to 1,156 mm) "A" 2- Brass, Chrome, White Polyester, or ENT' with dimensions 3-1/4" to 47-1/2" (82.5 to 1,207 mm) B - 155 F (68 C), 175 F (79'C), and 200 F (93 C) 3-Brass, Chrome, White Polyester, or ENT5 with "A" dimensions 3" to 47"(76.2 to 1,194 mm) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. "This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad- ditional approvals. FM Approved as corrosion proofing for corrosive environments. ' DESlGNCRlTERIA-FM (A1sofer to AvaI Crt 2 above) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-Bl tees. When selecting other CPVC fittings, contact Viking Technical Services. FM Approval Reuuirements: Standard Dry Pendent Sprinklers in the Approval Chart above are FM Approved as standard response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_071591 19.06.24 Rev 19.1 Exposed Barrel Ambient Ambient Temperature Temperature 40T/4'CI5eF/1eCI60F/16'C of Protected Areaw at the Exposed Minimum Barrel Discharge End Lengthww Face of Tee of the Sprinkler to Top of Ceiling ) ) ) 40'F (4'C) 0 0 1 0 30F (-1'C) 0 0 0 20'f' (-7'C) 14 (100) 0 0 lOT (-12'C) 8(203) 1(25.4) 0 0'F (-18'C) 12 (305) 3(76) 0 -10F (-23C) 14 (356) 4(102) 1(25.4) -20'F (-29'C) 14 (356) 6 (152) 3 (76) -30'F (-34'C) 16 (406) 8 (203 4 (102) -40'F (-40'C) 18 (457) 8(203) 4(102) -50'F (-46'C) 120 20(508)10(254 6(152) -60'F (-51'C) '508) 10 (254 6(152) (Exposed Barret) Ceiling 1-1/2' (38.1 mm) diameter 3-1/16 (Protected Area) i-,-, -- Page 7 of 7 "J I I(IF1G ® STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page. ,,- Install 1 inch NPT threaded / end of dry pendent sprink- / ter into the 1 inch NPT outlet of a malleable iron tee fitting per ANSI B 16.3 (Class 150) or cast iron threaded tee fitting per ANSI 16.4 (Class 125) only. Minimum ceiling opening diameter: Minimum able, order the 1-3/4' (44.5 mm) dry pendent sprink- Maximum ceiling opening diameter: Deflector at ter 1' (25.4 mm) 2-1/4' (57 mm). minimum distance shorter than the Seal the clearance below ceiling 'A' dimension. space around the sprinkler to avoid leak- Note: age of air into the ______ ______ protected area and To locate the deflector at the maximum distance 13/16' consequent formation __________________ —31(20.6 of condensate around below the ceiling, the frame, which could with no downward inhibit operation or adjustment avail- 4-7/16' able, order the tion. Refer to Figure cause premature opera- (112.7 mm) dry pendent sprink- Sleeve 7 below. Maximum ter 1' (25.4 mm) longer than the Finish If humidity and tenp- I A' dimension. matches erature differential ' escutcheon causes condensation on the exposed dry sprinkler, consider Deflector at wrapping the exposed maximum distance barrel with insulation, below ceiling Foam insulating tape, or equivalent, Up to 2' (50,8 mm) adjustment available. Note: To locate the deflector at the minimum distance below the ceiling, with no upward xThe protected area refers to the area below the ceiling. The ambient temperature is the temperature at the discharge end of the sprinkler. For protected area temperatures that occur between the values listed, use the next cooler temperature. **The minimum required barrel length is not the same as the 'A' dimension. Refer to Figures 3-5 for the 'A' dimension, NOTE: Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 6: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler is shown) ,r- Seal / (or equivalent method) ___ FSeat Clearance Insulated Opening Ceiling Dry Sprinkler Seal on the Dry Sprinkler Seal Within the Ceiling Exterior of the Ceiling Figure 7: Dry Sprinkler Seal (Adjustable Standard Dry Pendent Sprinkler is Shown) Form No. F_071591 19.06.24 Rev 19.1 Replaces Form No. F_071591 Rev 18.1.P65 (Added patent number.) This concludes the material submittal