Loading...
HomeMy WebLinkAbout4469 ADAMS ST; ; FPR2020-0012$City of PERMIT REPORT Carlsbad Print Date: 05/11/2021 Job Address: 4469 ADAMS ST, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2062000300 Track #: Valuation: $618,446.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check If: Plan Check U: Project Title: MARTIN RESIDENCE Description: MARTIN RESIDENCE -NEW 13D SPRINKLER SYSTEM (61 HEADS) Permit No: FPR2020-0012 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 02/24/2020 Issued: 03/06/2020 DEV15005 Finaled Close Out: 05/11/2021 Inspector: Final Inspection: Applicant: FPContractor: SYMONS FIRE PROTECTION SYMONS FIRE PROTECTION INC ANGELA ZUMAYA 12155 PAINE PL 12155 PAINE PL P0 WAY, CA 92064-7154 POWAY, CA 92064-7154 (619) 588-6364 (619) 588-6364 FEE AMOUNT FIRE NFPA 13D Single Family System (Insp/Bldg) $125.00 FIRE NFPA 13D Single Family System (Plan Review) $246.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov ff V'4 rEc, LI F F Li L • L 12155 PAINE PLACE P0 WAY, CA 92064 LICENSE C16-682025 HYDRAULIC CALCULATIONS FOR MARTIN RESIDENCE FILE NUMBER: 19-0937 DATE: 9-4-18 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm/512 sq. ft. AREA OF APPLICATION: M. BEDROOM COVERAGE PER SPRINKLER: 256 sqft. NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 26.1 gpm TOTAL WATER REQUIRED (including hose): 31.1 gpm (5 gpm Hose STREAM) FLOW AND PRESSURE (@ NODE 9 BOR): 26.1 gpm @9 psi SPRINKLER K-FACTOR (ORIFICE SIZE): 4.9 DESIGN/LAYOUT BY: FRANCISCO IBARRA AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-682025 WATER DEPARTMENT: CARLSBAD MUNICIPAL WATER DEPARTMENT CONTACT: VALERIE (760) 602-2750 WATER FLOW AVAILABILITY DATA: STATIC: 76 psi STATIC CALCULATIONS BY HASS COMPUTER PROGRAM HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 5/11/2020 C:\USERS\MDELATORRE\DESKTOP\19-0937.SDF JOB TITLE: MARTIN RESIDENCE TWO HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ T D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 68.4 67.0 500.0 68.4 31.1 54.9 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (PT) (PSI) (GPM) 1 5.0 SOURCE 54.9 31.1 2 7.0 - - - - 46.7 - - - 3 7.0 - - - - 42.7 - - - 4 0.0 - - - - 44.9 - - - 5 2.0 HOSE STREAM 41.4 5.0 6 10.5 - - - - 35.1 - - - 7 10.5 - - - - 30.1 - - - 7A 10.5 - - - - 19.5 - - - 8 10.5 - - - - 19.6 - - - 9 10.5 - - - 16.1 - - - 10 16.5 - - - - 7.8 - - - hA 12.5 K= 4.90 7.1 13.1 11 16.0 - - - - 8.0 - - - 12 16.0 - - - - 7.9 - - - 12A 12.5 K= 4.90 7.0 13.0 13 -1.5 - - - - 16.8 - - - 14 0.5 - - - - 23.2 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/11/2020 C:\USERS\MDELATORRE\DESKTOP\19-0937.SDF JOB TITLE: MARTIN RESIDENCE TWO HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (PT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.1 0.995 PL 20.00 PP 7.3 1 5.0 SRCE 54.9 (N/A) 12.8 150 FTG TG PE -0.9 2 7.0 0.0 46.7 0.0 0.252 TL 29.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 7.0 0.0 46.7 0.0 4.0 psi, 31.0 gpm 3 7.0 0.0 42.7 0.0 Pipe: 3 31.1 2.050 PL 85.00 PP 0.8 3 7.0 0.0 42.7 0.0 3.0 150 FTG 2E3L PE 3.0 4 0.0 0.0 44.9 0.0 0.007 TL 110.00 PV Pipe: 4 31.1 1.025 PL 5.00 PP 2.6 4 0.0 0.0 44.9 0.0 12.1 150 FTG E2L PE -0.9 5 2.0 H.S. 41.4 5.0 0.218 TL 12.00 PV Pipe: 5 26.1 1.101 PL 9.00 PP 2.7 5 2.0 H.S. 41.4 5.0 8.8 150 FTG ET2RC PE -3.7 6 10.5 0.0 35.1 0.0 0.111 TL 24.00 PV Pipe: 6 26.1 0.874 PL 6.50 PP 5.0 6 10.5 0.0 35.1 0.0 13.9 150 FTG ET PP 0.0 7 10.5 0.0 30.1 0.0 0.342 TL 14.50 PV Pipe: 7 13.3 0.874 PL 52.00 PP 10.6 7 10.5 0.0 30.1 0.0 7.1 150 FTG 8ET7R PE 0.0 8 10.5 0.0 19.6 0.0 0.098 TL 108.00 PV Pipe: 8 12.8 0.874 PL 57.60 PP 10.6 7 10.5 0.0 30.1 0.0 6.8 150 FTG 9E2T7R PE 0.0 7A 10.5 0.0 19.5 0.0 0.092 TL 115.60 PV Pipe: 9 4.2 0.874 PL 0.50 PP 0.0 8 10.5 0.0 19.6 0.0 2.3 150 FTG T PP 0.0 7A 10.5 0.0 19.5 0.0 0.012 TL 3.50 PV Pipe: 10 17.1 0.874 PL 7.00 PP 3.4 7A 10.5 0.0 19.5 0.0 9.1 150 FTG 2ET2R PE 0.0 9 10.5 0.0 16.1 0.0 0.156 TL 22.00 PV Pipe: 11 9.2 0.874 PL 61.00 PP 5.7 9 10.5 0.0 16.1 0.0 4.9 150 FTG 7E4T7R PE -2.6 10 16.5 0.0 7.8 0.0 0.049 TL 115.00 PV Pipe: 12 7.9 0.874 PL 96.00 PP 5.8 9 10.5 0.0 16.1 0.0 4.2 150 FTG 9E2T9R PE -2.4 12 16.0 0.0 7.9 0.0 0.037 TL 156.00 PV Pipe: 13 -5.1 0.874 PL 5.00 PP 0.2 12 16.0 0.0 7.9 0.0 2.7 150 FTG TR PE -0.2 10 16.5 0.0 7.8 0.0 --- -.- 0.017 - TL - 9.00 .---- PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/11/2020 C:\USERS\MDELATORRE\DESKTOP\19-0937.SDF JOB TITLE: MARTIN RESIDENCE TWO HEAD CALC PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (PT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13A 4.1 0.874 PL 2.50 PP 0.1 10 16.5 0.0 7.8 0.0 2.2 150 FTG T PE 0.2 11 16.0 0.0 8.0 0.0 0.011 TL 5.50 PV Pipe: 14 13.1 0.874 PL 15.00 PP 2.4 11 16.0 0.0 8.0 0.0 7.0 150 FTG 2E PE 1.5 hA 12.5 4.9 7.1 13.1 0.095 TL 25.00 PV Pipe: 15 13.0 0.874 PL 15.00 PP 2.4 12 16.0 0.0 7.9 0.0 7.0 150 FTG 2E PE 1.5 12A 12.5 4.9 7.0 13.0 0.094 TL 25.00 PV Pipe: 16 -9.0 0.874 PL 18.00 PP 1.2 11 16.0 0.0 8.0 0.0 4.8 150 FTG E2R FE 7.6 13 -1.5 0.0 16.8 0.0 0.048 TL 25.00 PV Pipe: 17 -9.0 0.874 PL 96.50 PP 7.3 13 -1.5 0.0 16.8 0.0 4.8 150 FTG 8E4T4R FE -0.9 14 0.5 0.0 23.2 0.0 0.048 TL 152.50 PV Pipe: 18 -9.0 0.874 PL 10.00 PP 0.7 14 0.5 0.0 23.2 0.0 4.8 150 FTG E PE -4.3 8 10.5 0.0 19.6 0.0 0.048 TL 15.00 PV NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.012 gpm and a maximum imbalance at any node of 0.196 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 13.9 ft/sec at pipe 6. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is 68.39 psi with a flow of 34.92 gpm. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/11/2020 C:\USERS\NDELATORRE\DESKTOp\19-0937.SDF JQB TITLE: MARTIN RESIDENCE TWO HEAD CALC (6) PIPE FITTINGS TABLE User Pipe Table Name: FSS.PIP PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Ell Tee TEERUN COUPLG EL45 0.874 5.00 3.00 1.00 0.00 1.00 1.00 0.00 1.00 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) B T L C B G A D Eli Tee 2.050 8.00 15.00 3.00 17.00 9.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/11/2020 C:\USERS\MDELATORRE\DESKTOp\19-0937.SDF JQB TITLE: MARTIN RESIDENCE TWO HEAD CALC WATER SUPPLY ANALYSIS Static: 68.40 psi Resid: 67.00 psi Flow: 500.0 gpm 80.0 70.0 - LEGEND 1 60. ( G A 2 U G 50.0 E P 40. C R E S S 30.0 U R E 20.0 1 jAvailable pressure 68.39 psi @ 31.1 gpm 2 gRequired pressure 54.89 psi 8 31.1 gpm Source Supply Curve System Demand Curve p S 10.0 i -14.7 10C150 200 250 300 350 400 450 500 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKL!R Y3T IN HYDRAULIC ANALYSIS Page 6 DATE: 5/11/2020 C:\USERS\MDELATORRE\DESKTOP\19-0937.SDF JQB TITLE: MARTIN RESIDENCE TWO HEAD CALC WATER SUPPLY CURVE 72+ 0\\\\\\\\\\\\\\\\\ * <-67.0 psi @ 500 gpm 66+ Flow Test Point 60+ x 54+ P 48+ R I E S I S 42+ U R I E I 36+ P S I I 30+ 24+ 18+ 12+ LEGEND X = Required Water Supply I 54.89 psi 8 31.1 gpm 6+ I 0 = Available Water Supply 68.39 psi 8 31.1 gpm 0++-+---+----+-----+ ------+ --------+ --------+ ---------+ -----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) Model RFC30 & RFC30LL Model RFC43 & RFC43LL Model RFC49 & RFC49LL Model RFC58 Bulletin 006 May 2019 Model RFC Series Residential Sprinklers Flat Concealed Pendent cULus Listed Features cULus Listed as Residential Sprinklers Push-On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL) and Australian WaterMark Certified (WMCS). Model RFC30 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link oper- ating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 135°F (570C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by ei- ther pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjust- ment. Model RFC58 and RFC76 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC cover plates are avail- able in a variety of finishes as listed in Table H. ( Model RFC Cover Plate Model RFC76 Sprinkler Model Nominal K-Factor gpmlpsi"2 (I/mm/bar"2) Max. Coverage Area ft x ft (m x m) Ustings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0(43) 14 x 14 (4.3 x 4.3) cULus RA061 1 RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL, WMCS RA321 1 RFC43 4.3(62) 20 x 20(6.1 x 6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20 (6.1 x 6.1) cULus, LL, WMCS RA3212 RFC49 4.9(71) 20 x 20 (6.1 x 6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3216 RFC58 5.8(84) 20x20(6.1 x6.1) cULus RA0613 RFC76 7.6(109) 20 x 20(6.1 x 6.1) cULus RA0618 cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). I WMCS: Australian WaterMark Certified. www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads; 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor. Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Cover Plate Sealing Assembly: Nickel Alloy with PTFE Model RFC cover plate Load Screw: Bronze Alloy Deflector. Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Sprinkler Wrench Model W3 (with wrench-able cap) I Bottom View Model FC (without wrench-able cap) Cup: Steel Listings and Approvals Cover Plate Finishes cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Watermark Certified (RFC49LL only) Model RFC49 & RFC49LL Sprinkler Components and Dimensions Threads J...,.. 2-6/16"(58 mm) Dia. Body - Cup Tower 1-3/4° (44 mm) ~1- 1/4" (6 mm) Fusible Link --. Nominal face of fitting to ceiling Deflector (retracted) \W'. 3/16' (5 mm Pin (extended) \ Deflector (extended) -1J-.JI f \ Model RFC Cover Plate 3-5/16° (84 mm) Dia. -.'.-4 Ceiling Model RFC49 & RFC49LL Sorinkler Hydraulic Desian Criteria Minimum Flow and Residual Pressure (1) Max. Coverage Area (2) Ordinary Temperature Intermediate Temperature _________________ Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) 16x16 13 7.0 13 7.0 (4.9x4.9) (49.0) (0.48) (49.0) (0.48) 18x18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20x20 20 16.7 21 18.4 (6.1x6.1) (75.7) (1.15) (79.5) (1.27) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table D above and (2) the flo w r e q u i r e d t o achieve a minimum design density of 0.1 gpmlsq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. cov e r a g e a r e a l i s t e d . Bulletin 006 Page 4 of 8 May 2019 www.reliablesprinkler.com Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1 00°C) sprinkler 165°F (74°C) cover plate Cover Plate Finishes 1' Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated El Satin Chrome Stainless Steel Clad(3) Custom Color Paint(2) Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. Custom color paint is semi-gloss, unless specified otherwise. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Co v e r p l a t e s are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Installation Dimensions Recommended Mm. to Mm. to Max. Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max Face Dropped Deflector Cover Plate Model Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model inch (mm) inch (mm) inch (mm) Ceiling() Ceiling Rating inch (mm) inch (mm) RFC30, RFC 3-5/16 2-5/8 1/2 1-1/2t02 1/2to1 135°F RFC30LL (84) (67) (13) (38 to 51) (13 to 25) (57°C) RFC43, 1350F'2' RFC43LL, RFC 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C) RFC49, (84) (67) (13) (38 to 51) (13 to 25) or 165°F'3' RFC49LL (74°C) 135°F'2' RFC58, RFC 3-5/16 2-5/8 3/4 1-1/2to2-1/4 1/4 to 1 (57°C) RFC76 (84) (67) (19) (38 to 57) (6 to 25) or 1650F'3' (74°C) Notes: Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2' x 1/2" brass nipple extension (Reliable PIN 6999991900) is available where necessary for replacement of existing sprinklers. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (381C). For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (66°C). Installation Model RFC series sprinklers are intended to be installed in ac- cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Mod- el RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench-able protec- tive cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench-able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed us- ing the Model FC wrench by temporarily removing the protec- tive cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permit- ted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engag- es the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PIFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20ff-lbs (19 to 27 N-m) for 3/4" thread sprinklers. Bulletin 006 May 2019 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or im- pairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- dent residential sprinklers. Model RFC 30 and RFC30LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (380C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprin- klers are available in either ordinary or intermediate tempera- ture classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (660C), respectively. Page 7 of 8 www.reliablesprinkler.com Model FC For use with Model RFC Series sprinklers without wrench-able cap installed Model W3 For use with Model RFC Series sprinklers with wrench-able cap installed Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire-protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwrit- ers Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Australian WaterMark Certified (RFC30LL, RFC43LL, and RFC49LL only). Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reHablesprinkler.com. Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) Temperature Rating Cover Plate Model RFC Temperature Rating Finish (See Table H) Sprinkler Wrench Model FC Model W3 Bulletin 006 Page 8 of 8 May 2019 11 Mim www.reIiablesprinkler.com Design Criteria tables in this Bulletin. For NFPA 13 applications, the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ mm), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model Fl Res Series sprinklers are listed for use in wet systems only. Bulletin 135 May 2019 1,iabl Model Fl Res Series Glass Bulb Residential Sprinklers cULus Listed Features cULus Listed Residential Sprinklers Available in pendent and horizontal sidewall orientations Decorative finishes available, including recessed escutch- eons and conical concealed cover plates Product Description Model FiRes Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The FiRes Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 130. Application The Model FiRes Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 130. The Model FiRes residential sprin- klers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 130. For NFPA 13R and NFPA 130 applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Residential Sprinkler Summary Sprinkler Sprinkler Identification Orientation K-Factor gpm/ps1112 Thread Size Installation Options Max. Coverage Area Model Number (SIN) (lpm/bar NPT or 1S07-1 ft x ft (m x m) F1Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) FiRes49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20x20(6.1 x6.1) F1Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res30CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed or Recessed 14x 14(4.3x4.3) FiRes49CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed or Recessed 20x20(6.1 x6.1) F1Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed or 20x20(6.1 x6.i) Recessed F1Res76 CCP R7618 Pendent 7.6(109) Conical Concealed or 20x20(6.i x6.1) Recessed F1Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1) F1Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1) F1Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20 (4.9 x 6.1) FiRes 58 HSWX RA3533 Horizontal Sidewall 5.8 (84) 1/2 Recessed 14 x 26 (4.3 x 7.9) w. reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or IS07-1R112 Temperature Ratings Nominal K-Factor 4.9 (71 metric) 155°F (68°C) Max. Working Pressure: 175 psi (12 bar) 175°F (79°C) - -. Material Specifications .i. Recessed Escutcheons Thermal Sensor: 3 mm glass-bulb Fl Recessed Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy R/ Recessed" Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector. Bronze Alloy Model W2 Model GFR2 (Recessed) * Model R/ escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res49 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4' (57mm) 2-1/4" (57mm) DIA. Face of fitting DIA. Face of fittino 1-15/16' to finished (49mm) DIA. ceiling 5/8'(l6mm) +1- 3/8' (9mm) F Rim 2-1/4" (57) 1-5/8'(4 3/8' 2-7/8" (72mm) Dimensions Fl Recessed Escutcheon Installation _.W I 1-3/4' (44mm) +1- 1/4' (6mm) 2-7/8' (72mm) DIA. P2 & FV Recessed Escutcheon Installation 1-15/16' to finished (49mm) DIA. ceiling 1/2'(l3mm) I +1- 1/4' (6mm) Model Fl Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems') !7 Maximum Coverage Area() ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) . Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 13(49) 7.0(0.48) 1 t 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 13 (49) 7.0 (0.48) 18 x 18(5.5 x 5.5) 17(64) 12.0(0.83) 20x20(6.1x6.1) 20(76) 16.7(1.15) 12 x 12(3.7 x 3.7) 15(57) 9.4(0.65) 4 to 8 inches (100(0200 mm) 14 x 14 (4.3 x 4.3) 16(61) 10.7 (0.74) 16 x 16(4.9 x 4.9) 17(64) 12.0(0.83) 18x 18(5.5x5.5) 19(72) 15.0(1.03) 20x20(6.1 x6.1) 22(83) 20.2(1.39) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or ( 2 ) t h e f l o w r e q u i r e d t o achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larg e r m a x . c o v e r a g e a r e a l i s t e d . Bulletin 135 Page 3 of 15 May 2019 www.reliablesprinkler.com Finishes Standard Finishes Special Application Finishes 7(ConicaQ Sprinkler") Fl, F2 RI, FP'), CCP, SWC (Conical) Sprinkler Fl, F2. RI, CCP, S Escutcheons Cover "J Escutcheons Cover Plates " Bronze Brass -- Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White White White Paint Black Black Black Paint Polyester (2) Polyester Polyester (2) Polyester -- - - Custom Color Custom Color Custom Color Paint Polyester Polyester Electroless Nickel -- PTFE'2 -- Notes Paint or any other coating applied over the factory finish will void all approvals and warranties. cULus Listed Corrosion Resistant. The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models Fl Res sprinklers are to be installed as shown in this bulletin. Model Fl, F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model F1 Res sprinklers. Not all F1 Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutch- eon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models F1 Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model GFR2 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Model GFR2 Installation of Fl Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for Fl or F2 recessed escutcheons; or 2-5/8" (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC-2 cover plates. Install Fl Res HSW sprinklers with a ceiling to deflector dis- tance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and "Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: 1/2" NPT and IS07-1R1/2: 8-18 ft-lbs (11 -24 N-m) 3/4" NPT and lS07-1R3/4: 14-20 ft-lbs (19-27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to mini- mize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Maintenance Reliable Model F1 Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuum- ing without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Model W2 Bulletin 135 Page 14 of 15 May 2019 www.reliablesprinkler.com Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadver- tent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler Model (See Table A) Temperature Rating Threads (NPT or lS07-1) Finish (See Table N) Escutcheon or Cover Plate Model Finish (See Table N) Sprinkler Wrench Model W2 (Pendent and HSW) GFR2 (Recessed and Concealed) Bulletin 135 Page 15 of 15 May 2019 www.reliablesprinkler.com LO CO C.'J 0 0) 0) 0) 0) 0) z VL KW lSPF'.ISI\E • • 12 155 PAiNE PLACE P0 WAY, CA 92064 HYDRAULIC CALCULATIONS FOR MARTIN RESIDENCE FILE NUMBER: 19-0937.SDF DATE: FEBRAURY 16, 2020 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm/ 512 sq.ft. AREA OF APLICATION: M. BEDROOM COVERAGE PER SPRINKLER: 256 sq.ft. NUMBER OF SPRINKLERS: 2 SPRINKLERS TOTAL SPRINKLER WATER FLOW REQUIRED: 26.0 gpm TOTAL WATER REQUIRED (including hose): 31.0 gpm FLOW AND PRESSURE (@ BOR): 26.0 gpm @ 53.9 psi SPRINKLER ORIFICE SIZE: 7/16" inch NAME OF CONTRACTOR: SYMONS FIRE PROTECTION, INC. DESIGN! LAYOUT: FRANCISCO IBARRA AUTHORITY HAVING JURISDICTION: CARLBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C 16-682025 WATER DEPARTMENT: CARLSBAD MUNICIPAL WATER DEPARTMENT CONTACT: VALERIE (760) 602-2750 WATER PRESSURE INFORMATION: 76 psi STATIC CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE #38071930) HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DAmE: 2/16/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0937.SDF JO' TITiE: MARTIN RESIDENCE TWO HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 68.4 67.0 500.0 68.4 31.0 67.2 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 5.0 SOURCE 67.2 31.0 2 7.0 - - - - 59.1 - - - 3 7.0 - - - - 55.1 - - - 4 0.0 - - - - 57.3 - - - 5 2.0 HOSE STREAM 53.9 5.0 6 10.5 - - - - 47.5 - - - 7 10.5 - - - - 19.6 - - - 8 10.5 - - - - 16.8 - - - 9 16.5 - - - - 8.3 - - - 10 16.5 - - - - 8.2 - - - bA 12.5 K= 4.90 7.0 13.0 11 16.0 - - - - 9.1 - - - 12 16.5 - - - - 8.2 - - - 12A 12.5 K= 4.90 7.0 13.0 13 -1.5 - - - - 17.5 - - - 14 -1.5 - - - - 24.1 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 2/16/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0937.SDF JOB TITLE: MARTIN RESIDENCE TWO HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.0 0.995 PL 20.00 PF 7.3 1 5.0 SRCE 67.2 (N/A) 12.8 150 FTG TG PE -0.9 2 7.0 0.0 59.1 0.0 0.251 TL 29.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 7.0 0.0 59.1 0.0 4.0 psi, 31.0 gpm 3 7.0 0.0 55.1 0.0 Pipe: 3 31.0 2.050 PL 85.00 PF 0.8 3 7.0 0.0 55.1 0.0 3.0 150 FTG 2E3L FE 3.0 4 0.0 0.0 57.3 0.0 0.007 TL 110.00 PV Pipe: 4 31.0 1.025 PL 5.00 PF 2.6 4 0.0 0.0 57.3 0.0 12.1 150 FTG E21, FE -0.9 5 2.0 H.S. 53.9 5.0 0.217 TL 12.00 PV Pipe: 5 26.0 1.101 PL 9.00 PF 2.7 5 2.0 H.S. 53.9 5.0 8.8 150 FTG ET2RC PE -3.7 6 10.5 0.0 47.5 0.0 0.111 TL 24.00 PV Pipe: 6 26.0 0.874 PL 38.00 PF 27.9 6 10.5 0.0 47.5 0.0 13.9 150 FTG 7E3T PE 0.0 7 10.5 0.0 19.6 0.0 0.340 TL 82.00 PV Pipe: 7 17.8 0.874 PL 9.50 PF 2.8 7 10.5 0.0 19.6 0.0 9.5 150 FTG T4R PE 0.0 8 10.5 0.0 16.8 0.0 0.168 TL 16.50 PV Pipe: 8 9.5 0.874 PL 66.00 PF 6.0 8 10.5 0.0 16.8 0.0 5.1 150 FTG 7E4T PE -2.6 9 16.5 0.0 8.3 0.0 0.053 TL 113.00 PV Pipe: 9 4.8 0.874 FL 2.50 PF 0.1 9 16.5 0.0 8.3 0.0 2.5 150 FTG T PE 0.0 10 16.5 0.0 8.2 0.0 0.015 TL 5.50 PV Pipe: 10 13.0 0.874 FL 15.50 PF 2.9 10 16.5 0.0 8.2 0.0 7.0 150 FTG 2ET2R FE 1.7 bA 12.5 4.9 7.0 13.0 0.094 TL 30.50 PV Pipe: 11 -8.2 0.874 FL 6.50 PF 0.7 10 16.5 0.0 8.2 0.0 4.4 150 FTG 2E PE 0.2 11 16.0 0.0 9.1 0.0 0.041 TL 16.50 PV Pipe: 12 4.7 0.874 FL 4.50 PF 0.1 9 16.5 0.0 8.3 0.0 2.5 150 FTG R FE 0.0 12 16.5 0.0 8.2 0.0 0.015 TL 5.50 PV Pipe: 13 13.0 0.874 PL 15.50 PF 2.9 12 16.5 0.0 8.2 0.0 7.0 150 FTG 2ET2R FE 1.7 12A 12.5 4.9 7.0 13.0 0.094 TL 30.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 2/16/2020 C:\PROGRAN FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0937.SDF JOB TITLE: MARTIN RESIDENCE TWO HEAD CALC PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 14 -8.3 0.874 PL 84.00 PF 6.0 12 16.5 0.0 8.2 0.0 4.4 150 FTG 9E6TR PE 2.6 8 10.5 0.0 16.8 0.0 0.041 TL 148.00 PV Pipe: 15 -8.2 0.874 PL 15.00 PF 0.9 11 16.0 0.0 9.1 0.0 4.4 150 FTG E2R PE 7.6 13 -1.5 0.0 17.5 0.0 0.041 TL 22.00 PV Pipe: 16 -8.2 0.874 PL 89.00 PF 6.6 13 -1.5 0.0 17.5 0.0 4.4 150 FTG 9E9TR PE 0.0 14 -1.5 0.0 24.1 0.0 0.041 TL 162.00 PV Pipe: 17 -8.2 0.874 PL 10.00 PF 0.7 14 -1.5 0.0 24.1 0.0 4.4 150 FTG E2R PE -5.2 7 10.5 0.0 19.6 0.0 0.041 TL 17.00 PV NOTES (HASS): Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.006 gpm and a maximum imbalance at any node of 0.086 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 13.9 ft/sec at pipe 6. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is 68.39 psi with a flow of 31.28 gpm. PIPE FITTINGS TABLE User Pipe Table Name: FSS.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 2/16/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0937.SDF JdB TITLE: MARTIN RESIDENCE TWO HEAD CALC PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 0.874 5.00 3.00 1.00 0.00 1.00 1.00 0.00 1.00 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B C A D Eli Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B C A D Eli Tee 2.050 8.00 15.00 3.00 17.00 9.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B C A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 2/16/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0937.SDF JOB TITLE: MARTIN RESIDENCE TWO HEAD CALC WATER SUPPLY ANALYSIS Static: 68.40 psi Resici: 67.00 psi Flow: 500.0 gpm :iswsj 70.0 60.0 G A U 50.0 G E 40.0 P R E 30.0 S S U 20.0 R E KIM p S 0.0 i -14.7 LEGEND 1 g Available pressure 68.39 psi @ 31.0 gpm 2 0 Required pressure 67.25 psi @ 31.0 gpm Source Supply Curve System Demand Curve 100150 200 250 300 350 400 450 500 FLOW (GPM) )te: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 2/16/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0937.SDF JOB TITLE: MARTIN RESIDENCE TWO HEAD CALC WATER SUPPLY CURVE 72+ 0\\\\\\\\\\\\\\\\\ X * <-67.0 psi @ 500 gpm 66+ Flow Test Point 60+ 54+ P48+ R E I S I 5 42+ U I R I E I 36+ P S I I 30+ 24+ 18+ 12+ LEGEND I, I X = Required Water Supply 67.25 psi @ 31.0 gpm 6+ I 0 = Available Water Supply I 68.39 psi @ 31.0 gpm I, 0++-+---+----+-----+------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) Bulletin 006 January 2020 Relmlabi Model RFC Series Residential Sprinklers Flat Concealed Pendent cULus Listed Features cULus Listed as Residential Sprinklers Push-On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL) and Australian WaterMark Certified (WMCS). Model RFC30 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link oper- ating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC30 & RFC30LL Model RFC43 & RFC43LL Model RFC49 & RFC49LL Model RFC58 Model RFC Series sprinklers are installed with a Model RFC or Model G5 Cover Plate. Model G5 Cover Plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjustment. Model RFC58 and RFC76 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC and G5 Cover Plates are available in a variety of finishes as listed in Table H. Model RFC76 0 Model RFC & G5 Cover Plate Sprinkler Model Nominal K-Factor gpm/p5i112 (I/mm/bar112) Max. Coverage Area ft x ft (m x m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0(43) 14x 14(4.3x4.3) cULus RA0611 RFC30LL 3.0(43) 14 x 14(4.3 x 4.3) cULus, LL, WMCS RA3211 RFC43 4.3(62) 20x20(6.1 x6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3212 RFC49 4.9(71) 20x20(6.1 x6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3216 RFC58 5.8(84) 20x20(6.1 x6.1) cULus RA0613 RFC76 7.6(109) 20x20(6.1 x6.1) cULus RA0618 cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). WMCS: Australian WaterMark Certified. www.reliablesprinkler.com Bottom View Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC30LL only) Watermark Certified (RFC30LL only) Model RFC30 & RFC30LL Sprinkler Components and Dimensions 2-5/16"(58 mm) Threads Dia. Body Cup Tower 1-3/4' (44 mm) +/- 1/4"(6 mm) Fusible Link Nominal face of fitting to ceiling Deflector (retracted) 3/16"(5 mm) IPin (extended) r-I-- -i Deflector (extended) Model G4/G5 Cover Plate 3-5/16"(84 mm) Dia. —1 V Ceiling Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure (1) Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 12x12 9 9.0 (3.6 x 3.6) (34) (0.62) 14x14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: 1 For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 2 of 8 January 2020 www.reliablesprinkler.com Bottom View Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1131/2 Nominal K-Factor: 4.3 (62 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Listings and Approvals Cover Plate Finishes cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC43LL only) Watermark Certified (RFC43LL only) Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1000C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Model RFC43 & RFC43LL Sprinkler Components and Dimensions 2-5/16° (58 mm) Threads - Body Cup - Tower -, Fusible Link - Deflector (retracted) Pin (extended) Deflector (extended) - Dia. 1-3/4"(44 mm) 1/4"(6 mm) Nominal face of fitting to ceiling r- 3/16°(5 mm) Model G4/G5 Cover Plate -' I - 3-5/16'(84 mm) Dia. Ceiling Model RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure (1) Max. Coverage Area (2) Ordinary Temperature ____________________ Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) 15x15 12 7.8 12 7.8 (4.6 x 4.6) (45) (0.54) (45) (0.54) 16x16 13 9.1 13 9.1 (4.9 x 4.9) (49) (0.63) (49) (0.63) 18x18 18 17.5 (5.5x5.5) (68) (1.21) -- -- 20x20 21 23.8 (6.1x6.1) (79) (1.64) -- -- Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 ñiiIibI Page 3 of 8 January 2020 www.reliablesprinkIer.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Cover Plate Sealing Assembly: Nickel Alloy with PTFE Model G5 Cover Plate Load Screw: Bronze Alloy Towers: Copper Alloy Sprinkler Wrench Pins: Stainless Steel Model FC (without wrench-able cap) Deflector: Bronze Alloy Model W3 (with wrench-able cap) Bottom View Cup: Steel Cover Plate Finishes Listings and Approvals cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Watermark Certified (RFC49LL onlv) Model RFC49 & RFC49LL Sprinkler Components and Dimensions JsLIIC 2-5/16" (58 mm) Threads Dia. Body Towe j1 _ _J — Cup 1-3/4' (44 mm) +1- 1/4(6mm) Fusible Link Deflector r—.3/l6(5 mm) Deflector (extended) Nominal face of fitting to ceiling Pin (extended) ±? Model G4/G5 Cover Plate 3-5/16" (84 mm) Dia. 7celling Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure (1) Max. Coverage Area Ordinary Temperature ___________________ Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) 16x16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) 18x18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20x20 20 16.7 21 18.4 (6.1 x6.1) (75.7) (1.15) (79.5) (1.27) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 4 of 8 January 2020 www.reliablesprinkler.com Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1 00°C) sprinkler 165°F (74°C) cover plate Bottom View Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Chrome Plated Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1 00°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed Model RFC58 Sprinkler Components and Dimensions Threads - Body Cup Tower -.., Fusible Link - Deflector (retracted) Pin (extended) Deflector (extended) 1-7/8"(48 mm) +1- 318"(9 mm) Nominal face of fitting to ceiling L.... 2-5/16"(58 mm) Dia. 3/16'(5 mm) F, Model G4/G5 Cover Plate 3-5/16 (84 mm) Dia. Ceiling Model RFC58 Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure 1) 7 Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 16x16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18x18 18 9.6 (5.5 x 5.5) (68.1) (0.66) 20x20 20 11.9 (6.1 x6.1) (75.7) (0.82) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 M Page 5 of 8 January 2020 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed Model RFC76 Sprinkler Components and Dimensions 2-5/16"(58 mm) Dia. Threads Body Cup Tower Fusible Link 1-7/8' (48 mm) +/- 3/8' (9 mm) Il_i I Nominal face of fitting to ceiling Deflector (retracted) Pin (extended) Deflector (extended) Model G4/G5 Cover Plate -' I- 3-5/16"(84 mm) Dia. r- 3/16"(5 mm) Ceiling Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure 1 Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 16x16 21 7.6 (4.9 x 4.9) (79.5) (0.52) 18x18 24 9.9 (5.5 x 5.5) (90.8) (0.68) 20x20 34 20 (6.1 x6.1) (128.7) (1.4) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 6 of 8 January 2020 R 11abld www.reliablesprinkler.com Cover Plate Finishest1 Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Color Paint(2) Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. Custom color paint is semi-gloss, unless specified otherwise. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Cover plates are not listed or approved as corrosion resistant. Installation Dimensions Table J Recommended Mm. to Mm. to Max. Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Model Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model inch (mm) inch (mm) inch (mm) Ceiling 1 Ceiling Rating inch (mm) inch (mm) RFC30, RFC; or 3-5/16 2-5/8 1/2 1-1/2to2 1/2to1 135°F RFC30LL G5 (84) (67) (13) (38t051) (13t025) (57°C) RFC43, 1350F2) RFC43LL, RFC or 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C) RFC49, G5 (84) (67) (13) (38 to 51) (13 to 25) or 165°F 3 RFC49LL (74°C) 135°F 2 RFC58, RFC or 3-5/16 2-5/8 3/4 1-1/2t02-1/4 1/4to1 (57°C) RFC76 G5 (84) (67) (19) (38 to 57) (6 to 25) or 165°F13 (74°C) Notes: Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (380C). For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (66°C). Installation Model RFC series sprinklers are intended to be installed in accordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Model RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench-able protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench-able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permitted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-lbs (19 to 27 N-m) for 3/4" thread sprinklers. Bulletin 006 January 2020 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pendent residential sprinklers. Model RFC 30 and RFC30LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (380C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are available in either ordinary or intermediate temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (660C), respectively. Page 7 of 8 www.reliablesprinkler.com Model FC For use with Model RFC Series sprinklers without wrench-able cap installed Model W3 For use with Model RFC Series sprinklers with wrench-able cap installed a Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire-protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwrit- ers Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Australian WaterMark Certified (RFC30LL, RFC43LL, and RFC49LL only). Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) Temperature Rating Cover Plate Model RFC or G5 Temperature Rating Finish (See Table H) Sprinkler Wrench Model FC Model W3 Bulletin 006 Page 8 of 8 January 2020 Relinbl www.reIiablesprinkler.com V4 Bulletin 135 October 2019 Re Model Fl Res Series Glass Bulb Ii a b I e Residential Sprinklers cULus Listed Features cULus Listed Residential Sprinklers Available in pendent and horizontal sidewall orientations Decorative finishes available, including recessed escutch- eons and conical concealed cover plates Product Description Model FiRes Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The FiRes Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model FiRes Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model FiRes residential sprin- klers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ mm), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model Fl Res Series sprinklers are listed for use in wet systems only. Residential Sprinkler Summary Sprinkler Sprinkler Identification Orientation K-Factor gpm1psi112 Thread Size Installation Options Max. Coverage Area Model Number (SIN) (lpm/bar112) NPTorlSO7-1 ftxft(mxm) F1Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x1 6 (4.9 x 4.9) F1Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20x20(6.1 x6.1) F1Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res30CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed or 14x 14(4.3x4.3) Recessed F1Res49 CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res58CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed or Recessed 20x20(6.1 x6.1) F1Res76 CCP R7618 Pendent 7.6(109) Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1) F1Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1) F1Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8 (84) 1/2 Recessed 14 x 26 (4.3 x 7.9) www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPTor 1507-1R1/2 Nominal K-Factor: 3.0 (43 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) 175°F (79°C) Material Specifications Thermal Sensor: 3 mm glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy R/ Recessed* Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res30 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4° (57mm) DIA. 1-15/16" (49mm) DIA. Face of fitting to finished ceiling 1/2° (13mm) +/- 1/4° (6mm) Threads Wrench Flat Sealing Assembly 2-1/4" Glass Bulb (57mm) Load Screw Deflector (32mm) Components Dimensions 1-3/4" (44mm) +1- 1/4° (6mm) 2-7/8° (72mm) F2 & FV Recessed Escutcheon Installation Model F1Res30 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems') Maximum Coverage Aream ft. x ft.(m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 8(30) 7.0(0.48) 1 t 4 inches (25t0100mm) 14 x 14(4.3 X 4.3) 10(38) 11.0 (0.76) 15 x 15 (4.6 x 4.6) 12(45) 16.0(1.1) 16 x 16 (4.9 x 4.9) 13(49) 18.8(l.3) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 AiiibI Page 2of 15 October 2019 www.reliablesprinkler.com to finished ceiling 5/8" (16mm) +1- 3/8" (9mm) Fl Recessed Escutcheon Installation Dimencinnq Technical Specifications Style: Pendent and Recessed Pendent Threads: 1/2" NPT or lS07-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass-bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons Fl Recessed F2 Recessed FV Recessed* Sprinkler Wrenches Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res49 Residential Pendent Sprinkler Components and Installation Dimensions tuiiw 2-1/4" (57mm) 2-1/4" (57mm) DIA. Face of fittinci DIA. Face of fittinn 1-15/16" to finished (49mm) DIA. ceiling 1/2"(l3mm) '1- 1/4" (6mm) W T 1-3/4" (44mm) +1- 1/4" (6mm) L 2-7/8" (72mm) DIA. F2 & FV Recessed Escutcheon Installation Model F1Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 13 (49) 7.0(0.48) 1 t 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 13 (49) 7.0 (0.48) 18 x 18 (5.5x 5.5) 17(64) 12.0 (0.83) 20x20(6.1x6.1) 20(76) 16.7(1.15) 12 x 12 (3.7 x 3.7) 15 (57) 9.4 (0.65) 4 to 8 inches (10010200 mm) 14 x 14(4.3 x 4.3) 16(61) 10.7 (0.74) 16 x 16(4.9 x 4.9) 17 (64) 12.0 (0.83) 18 x 18(5.5 x 5.5) 19(72) 15.0 (1.03) 20x20(6.1 x6.1) 22(83) 20.2(1.39) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 iiii Page 3 of 15 October 2019 www.reliablesprinkler.com to finished ceiling 5/8° (16mm) +1- 3/8° (9mm) Fl Recessed Escutcheon Installation Dimensions Technical Specifications Style: Pendent and Recessed Pendent Threads: 1/2" NPT or lS07-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons Fl Recessed F2 Recessed FV Recessed* Sprinkler Wrenches Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res58 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) 2-1/4(57mm) h-r- DIA. Face of fittino hT- DIA. ilFace of fitfinri 1-15/16° to finished (49mm) DIA. ceiling 1/2"(l3mm) +/- 1/4" (6mm) L_ - .... j 13im 2-7/8° (72mm) DIA. F2 & FV Recessed Escutcheon Installation Model F1Res58 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems'11 Maximum Coverage Area'2' ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16(4.9 x 4.9) 16(61) 7.6 (0.52) 1 to 4 inches (25 to 100n 18 x 18 (5.5 x 5.5) 19 (72) 10.8 (0.75) 20x20(6.1 x6.1) 22(83) 14.4(1.0) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 N Lm Page 4of 15 October 2019 www.reliablesprinkler.com Technical Specifications Finishes (See Table N) Style: Pendent and Recessed Pendent Threads: 3/4" NPT or lS07-1 R3/4 Temperature Ratings Nominal K-Factor: 7.6 (109 metric) 155°F (68°c) Max. Working Pressure: 175 psi (12 bar) 175°F (79°C) Material Specifications Recessed Escutcheons Thermal Sensor: 3 mm glass bulb Fl Recessed Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed* Sealing Assembly Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res76 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4'(57m 2-1/4° (57mm) DIA. -r Face of fitting DIA Face of fitting 1-15/16° to finished /1 6° to finished (49mm) DIA. ceiling (49mm) DIA. ceiling 5/8"(16mm) 1/2° (13mm) Ft, 03M 3/8" (9mm) +1- 1/4" (6mm) 2-1/4° I 1-5/8" - (41 mm) +1- 1 3/4 (44mm) 3/8 (6mm) +1- 9mm) 2-7/8°(72mm) DlA. (44mm) -2-7/8" (72mm) DIA L Dimensions Fl Recessed Escutcheon Installation F2 &FV RecessedEscutcheonInstallation Model Fl Res76 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area(2) Flow Pressure Deflector to ft.x ft. (M xm) gpm(I/mm) psi (bar) Ceiling Distance 18 x 18 (5.5 x 5.5) 21(80) 7.6 (0.52) 1 to 4 inches (25 to 100 mm) 20 x 20 (6.1 x 6.1) 23 (87) 9.2 (0.63) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Pages of 15 October 2019 www.reliablesprinkler.com CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPT or 1S07-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor. 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57OC)* FP Recessed* Sprinkler Wrenches Model GFR2 *Note: Model FP escutcheons and CCP cover plates are not listed for use in positively pressurized ceiling plenums. Model Fl Res3O CCP and FP Recessed Pendent Sprinkler Installation Dimensions 2-5/8" (67mm) 2-5/8" (67mm) I DIA. 1 I I I DIA. 1 I 2-5/16 (59mm)DIA. ace of fitting to finished ceiling I l _______________________________ Face of fitting to finished ceiling I 1/4" (32mm) "ej Li-1/4 (32mm) 1/4(6mm) .,-.z,z I I +1- 1/4° (6mm) 15/16" 1" (25mm) (24mm) .'?II" +1- 1/4° (6mm) L3-3/16"(78mm) DIA.- FP Recessed Escutcheon Installation Model F1Res3O CCP Pendent &FPRecessedPendentSprinklerHydraulicDesignCriteria Minimum Flow and Residual Pressure in Wet Pipe Systems 1 Maximum Coverage Area' ft x ft. (m x m) I Flow I gpm (I/mm) I Pressure I psi (bar) I I Deflector to Ceiling Distance 7 12 X 12(3.7 X 3.7) 8(30) 7.0(0.48) 1/2 to 1 inch (13 to 25 mm) 14x 14(4.3x4.3) I 11(38) 13.4(0.92) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 MEMO Page 6of 15 October 2019 qW www.reliablesprinkler.com 9/" lf7n,m CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPT or lS07-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (570C)* FP Recessed* Sprinkler Wrenches Model GFR2 *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model F1Res49 CCP & FP Recessed Pendent Sprinkler Installation Dimensions -5/8° (67mm) DIA. 2-5/16' (59mm)DIA. ace of fitting to finished ceiling 1/4" (32mm) f-1/4"(6mm) I I __________________________ __________________________ Face of fitting to finished ceiling Li-1/4° (32mm) I +/-1/4°(6m) I (24mm) L3-3/16"(78mm) DIA. - FPRecessedEscutcheonInstallation Model F1Res49 CCP Pendent and FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems" Maximum Coverage Area() ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 7 14x14(4.3x4.3) 13(49) 7.0(0.48) 1/2 to 1 inch (13 to 25 mm) 16.7(1.15) 16 X 16(4.9 X 4.9) 14(53) 8.2(0.57) 18 x 18 (5.5 x 5.5) 18(68) 13.5(0.93) 20x20(6.1x6.1) 20(76) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 ñiiiie Page 7of 15 October 2019 www.reliablesprinkler.com CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2' NPTor 1S07-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (570C)* FP Recessed* Sprinkler Wrenches Model GFR2 (Recessed) *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res58 CCP and FP Recessed Pendent Sprinkler Installation Dimensions 2-5/8° (67mm) 2-5/8(67mm) I I DIA. 1 1 DIA. 1 I - 2-5/16° (59mm)DIA. ace of fitting to finished ceiling I ___________________________________ _______________________________ Face of fitting to finished $ ceiling I 1/4° (32mm) I 1-1/4°(32mm) - 1/4(6mm) 24mm) -•'T 1/4°(6rnm) L3-3/16"(78mm) DIA.- FP Recessed Escutcheon Installation Model Fl Res58 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems'" Maximum Coverage Area(2) ft. xft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16(4.9 x 4.9) 16(61) 7.6 (0.52) 1/2 to 1 inch (13 to 25 mm) 18 x 18(5.5 x 5.5) 19(72) 10.8 (0.75) 20x20(6.1 x6.1) 22(83) 14.4(1.0) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 8of 15 October 2019 0401rawid www.reliablesprinkler.com °) A10. CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 3/4" NPT or lS07-1 R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (570C)* FP Recessed* Sprinkler Wrenches Model GFR2 (Recessed) *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res76 CCP and FP Recessed Pendent Sprinkler Installation Dimensions 2-5/8° (67mm) DIA. 2-5/16° (59mm)D1A ace of fitting to finished ceiling I _____________________ Face of filling to finished ceiling I 1/4(32mm) rim I 1-1/4 (32mm) 1/4° (6mm) 1/4° (6mm) / / / // (24mm) .. .+/-1/4°(6mm) L3-3/18"(78mm) DIA. FP Recessed Escutcheon Installation Model 1171Res76 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(Z ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16 (4.9 x 4.9) 21(80) 7.6 (0.52) 1/2to1 inch (13 to 25 mm) 18 x 18 (5.5 x 5.5) 22 (83) 8.4 (0.58) 20 x 20(6.1 x 6.1) 25(95) 10.8(0.75) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 WNW Page 9 of 15 October 2019 www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2" NPT or 1507-1R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Model F1Res44 Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-5/8" (41mm) 3/8° (10mm) +1- 1/4° (6mm) +/-1/4"(6mm) -I 2-7/16" (62mm) _ 2-1/4" 1-15/16" (57mm) (49mm) 5/1j DIA. DIA (8mm) 1 Top of Deflector Down from Ceiling to be Either 4" to 6" (100 to 150 mm) or 6" to 12° (150 to 300 mm) Based on Hydraulic Calculations Dimensions F2&FVRecessedEscutcheonInstallation Model F1Res44 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems" Maximum Coverage Areat2t ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 7 12 x 12 (3.7 x 3.7) 12(45) 7.5(0.52) 4 to 6 inches (100 to 150 mm) 18.7(1.29) 14 x 14 (4.3 x 4.3) 14(53) 10.2(0.70) 15 x 15(4.6 x 4.6) 15(57) 11.6(0.80) 16 x 16 (4.9 x 4.9) 16(61) 13.3(0.92) 16 x 18 (4.9 x 5.5) 18(68) 16.8(1.16) 16 x 20 (4.9 x 6.1) 23(87) 27.4(1.89) 18 x 18 (5.5 x 5.5) 19(72) 12 x 12 (3.7 x 3.7) 14(53) 10.2(0.7) 6 to 12 inches (150 to 300 mm) 27.4(1.89) 14 x 14 (4.3 x 4.3) 16(61) 13.2(0.91) 15X15(4.6X4.6) 16(61) 13.2(0.91) 16 x 16 (4.9 x 4.9) 17(64) 15.0(1.03) 16 x 18 (4.9 x 5.5) 20(76) 20.7(1.43) 16 x 20 (4.9 x 6.1) 23(87) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page lOofiS October 2019 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Sidewall Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass-bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) (1) Cover Plates SWC Conical Concealed Plate (2) SWC-2 (Slotted) Conical Concealed Plate (3) Sprinkler Wrenches Model GFR2 SWC-2 Note: "Not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating. 21135°F SWC Conical Concealed Plate for 155°F (68°C) sprinklers 131135°F SWC-2 (Slotted) Conical Concealed Plate for 175°F (79°C) sprinklers Model Fl Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions 1 (25mm) 1 (25mm) +1- 1/4 16mm +1- 1/4 (6mm) Face of fitting to finished wall ---2-7/16(62mm)----- 5/16 j (8mm) Dimensions (67mm) P(41mm) - - SWC & SWC-2 Concealed Cover Plate Installation Top of Deflector Down from Ceiling to be Either 3 5/16w 4 to 6 (100mm to (84mm) lsomm) or 6t0 12 DIA. (150mm to 300mm) Based on Hydraulic I Calculations I Model Fl Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area(2) ft. x ft. (m x m) Ordinary Temperature Rating 155°F (68°C) Intermediate Temperature Rating 175°F (79°C) Deflector to Ceiling Distance psi (bar) Flow gpm (I/mm) Pressure psi (bar) Flow gpm (I/mm) Pressure 12 x 12(3.7 x 3.7) 13(49) 8.7 (0.60) 14(53) 10.2 (0.7) 14 x 14(4.3 x 4.3) 14(53) 10.2 (0.7) 14(53) 10.2 (0.7) 15 x 15(4.6 x 4.6) 16(61) 13.2 (0.91) -- -- 4 to 6 inches 16x 16(4.9x4.9) 17(64) 15.0(1.03) -- -- (100 to 150 mm) 16x 18(5.5 x5.5) 19(72) 18.7(l.31) -- -- 16 x 20 (4.9 x 6.1) 23 (87) 27.4(l.89) - - - - 12 x 12(3.7 x 3.7) 14(53) 10.2 (0.7) -- -- 6 to 12 inches (150t0300mm) 14x 14 (4.3x4.3) 15(57) 11.7 (0.81) -- -- 15x 15(4.6x4.6) 17(64) 15.0(1.03) -- -- 16 x 16 (4.9 x 4.9) 18(68) 16.8(1.16) -- -- 16x 18(4.9x5.5) 20(76) 20.7(l.43) -- Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Aiiii Page 11 of 15 October 2019 www.reliablesprinkler.com Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FVRecessed Sprinkler Wrenches Model W2 Model GFR2_(Recessed) Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2" NPT or 1507-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Model Fl Res58 Residential Horizontal Sidewall Sprinkler Installation Dimensions _IuIi Face of fitting to finished wall 1-5/8" (41 mm) 3/8(10mm) +1- 1/40 (6mm) +1- 1/4(6mm) 2-7/16" (62mm) 2-1/4" 1-1/16" D j (57mm) (49mm) IA. DIA 5/16" (8mm) Top of Deflector Down from Ceiling to be Either 4" to 60 (100 to l5o mm) 0r6"to 12° (150 to 300 mm) Based on Hydraulic Calculations Dimensions & F'! Recessed Escutcheon Installation Model FlRes58 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Aream ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12x 12(3.7x3.7) 16(61) 7.6 (0.52) 4 to 6 inches (100 to 150 mm) 25.0(1.72) 14 x 14(4.3 x 4.3) 18 (68) 9.7 (0.66) 15 X 15(4.6 X 4.6) 19(72) 10.7 (0.74) 16x 16(4.9x4.9) 21(80) 13.2(0.91) 16x 18(5.5x5.5) 25(95) 18.6(1.28) 16 x 20(4.9 x 6.1) 29(110) 12 x 12(3.7 x 3.7) 22(83) 14.4(l.0) 6 to 12 inches (150 to 300 mm) 28.6(1.97) 14 x 14(4.3 x 4.3) 22(83) 14.4(1.0) 15 x 15 (4.6 x 4.6) 24(91) 17.1 (1.18) 16x 16(4.9x4.9) 26(98) 20.1 (1.39) 16x 18(4.9x5.5) 31(117) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 12 of 15 www.reliablesprinkler.com 2019 sprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2" NPT or lS07-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Model Fl Res58 HSWX Residential Horizontal Sidewall Sprinkler Installation Dimensions _IuIF Face of fitting to finished wall 1-7/8" (48mm) 3/8"(10mm) +/-1/4°(6mm) +/- 1/4(6mm) 2-7/8°(73mm) - (8mm) 2-1/4' 1-15/16" Top of Deflector Down From Ceiling to be Either 4" to 6" (57mm) (49mm) — F (100 to 150 mm) or 6" to 12" DIA. DIA. (150 to 300 mm) Based on Hydraulic Calculations Dimensions F2 &FV Recessed EscutcheonInstallation Model F1Res58 HSWX Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemst Maximum Coverage Area(2) ft.x ft.(mx m) Flow gpm(I/mm) Pressure psi(bar) Deflector to CeilingDistance 18 x 20 (5.5 x 6.1) 30(114) 26.8(1.85) 4 to 6 inches (100 to 150 mm) 52.4(3.63) 20 x 20 (6.1 x 6. 1) 30(114) 26.8(1.85) 16 x 22 (4.9 x 6.7) 33(125) 32.4(2.23) 16x24(4.9x7.3) 38(144) 42.9(2.96) 14x26(4.3x7.9) 42(160) 18 x 20 (5.5 x 6. 1) 35(133) 36.4(2.51) 6 to 12 inches (150 to 300 mm) 62.9(4.34) 16 X 22(4.9 X 6.7) 38(144) 42.9(2.96) 16x24(4.9x7.3) 42(160) 52.4(3.61) 14x26(4.3x7.9) 46(174) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 13 of 15 October 2019 Rellabild www.rel iablesprinkler.com Finishes _151_ Standard Finishes Special Application Finishes Sprinkler" Fl, F2. FV CCP, SWC (Conical) Sprinkler (1) Fl, F2. Al, FP3, CCP, SWC (Conical) Escutcheons Cover Plates Escutcheons Cover Plates (I) Bronze Brass -- Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White White White Paint Black Black Black Paint Polyester (2) Polyester Polyester (2) Polyester -- -- -- Custom Color Custom Color Custom Color Paint Polyester Polyester Electroless Nickel -- -- -- PTFE (2) -- -- Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. cULus Listed Corrosion Resistant. The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models Fl Res sprinklers are to be installed as shown in this bulletin. Model Fl, F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model F1 Res sprinklers. Not all F1 Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutch- eon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res sprinklers, use only the Model W2 sprinkler Wrench: for installing Models Fl Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model GFR2 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Model W2 Model GFR2 Installation of Fl Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for Fl or F2 recessed escutcheons: or 2-5/8" (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC-2 cover plates. Install F1 Res HSW sprinklers with a ceiling to deflector dis- tance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and "Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: 1/2" NPT and 1S07-1R1/2: 8-18 ft-lbs (ii —24 N-m) 3/4" NPT and 507-1 R3/4: 14-20 ft-lbs (19-27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to mini- mize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Maintenance Reliable Model F1 Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuum- ing without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Bulletin 135 Page 14 of 15 October 2019 www.reliablesprinkler.com Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadver- tent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler Model (See Table A) Temperature Rating Threads (NPTor 1S07-1) Finish (See Table N) Escutcheon or Cover Plate Model Finish (See Table N) Sprinkler Wrench Model W2 (Pendent and HSW) GFR2 (Recessed and Concealed) LU c..J 0 N-0) 0) 0) 0) 0) 0 Bulletin 135 Page 15 of 15 October 2019 www.reliablesprinkler.com