Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5770 ARMADA DR; ; FPC2019-0073
J1:1 P S I 1 I Zis] 41 (7city of Carlsbad =ire PRO, M1111".. ii Print Date: 07/22/2024 Permit No: FPC2019-0073 Job Address: 5770 ARMADA DR, CARLSBAD, CA 92008-4608 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel f: 2110222600 Track #: Applied: 03/19/2019 Valuation: $0.00 Lot #: Issued: 04/29/2019 Occupancy Group: Project : Finaled Close Out: 07/22/2024 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix Plan Check #: Fieri, Dominic Project Title: Description: SEASPINE -FIRE ALARM TI (ADD NOTIFICATION DEVICES & PULL STATIONS THROUGHOUT BLDG) Applicant: TNG SECURITY INC 4241 PONDEROSA AVE, # STE D SAN DIEGO, CA 92123-6500 (858) 503-7500 FEE AMOUNT FIRE Hourly Services Each Additional Hour $272.00 FIRE Hourly Services First Hour $159.00 FIRE Hourly Services First Hour $159.00 FIRE TI Fire Alarm System $620.00 Total Fees: $1,210.00 Total Payments To Date: $1,210.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 I Inspections: 442-339-2660 1 www.carlsbadca.gov FPC20190073 577O ARMADA I SEASPINE - FIRE ALARM TI (ADD NOTIFICATION FIRE PEiRivilT DEVICES PULL STATIONS THROUGHOUT BLDG) 1635 Faraday Ave., C Phone: 760-602-4665 www.carlsL, RECE WED MAR 19 2019 CAR LS BAD FIRE DEPARTMENT 2110222600 3/19/2019 FPC201 9-0073 Project Information Project Name Project Address '77Q ,4-ru'4taoL.- Ar,t.i Suite# Scope of Work'AJ) O(fs f pIt ch'LClc Arl Associated Building Permit #(if applicable) NlA ai"d - Adc're,' W)&- 6614,N-q7 El Fire Sprinkler System: Number of risers LFire Alarm LII Sprinkler Monitoring El New system %iTenant Improvement Number of heads El Underground: Number of hydrants El Other: Contractor Information Company Name C't frr Cov-.ifrQrC (al Address city J4''1 C City state C'4 zip 2 123 Applicant Name VO4 Phoneg ç)gt0ç3 Email k-'€ Contractor License Number and Type c-.IO _13 1~6 Exp. Date City Business Lic se Nu ber Signature Date Sli q 1/9 _______________ Submittal Package for: Seaspine 5770 Armada Drive Carlsbad, CA 92008 California Commercial Security 9560 Ridgehaven Court, Suite C San Diego, CA 92123 Contains Cutsheets and CSFM Listings for: EXISTING Fire Alarm Control Panel EXISTING Remote Annunciator Power Supply Document Cabinet Relay Input Module Relay Module Smoke Detector HEat Detector Manual Pull Station Strobe Horn/Strobe Weatherproof Strobe Weatherproof Horn/Strobe DPG 3/1/2019 0 L DF-60601:A1 • A1-60 MS.9200UDLS(E) Rev 3 Intelligent Addressable FACP with Built-In Communicator (a FirelffeWarms by Honeywell Ada ressa 61 51Fi Al Ciiti II el General 0 The Fire•Lite MS-9200UDLS Rev 3 with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. While the MS-9200UbLS Rev 3 may be used with an SLC configured in the CLIP (Classic Loop Interface Protocol) mode, it can also operate in LiteSpeedTM mode—Fire.Lite's latest polling technology—for a quicker device response time. LiteSpeed's patented technology polls 10 devices at a time. This improvement allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification cir- cuits in under 10 seconds. With Litespeed polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The MS-9200UDLS Rev 3's quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is com- pleted, the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, additional secondary ANN-BUS, and increasedpower for the resettable and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polar- ity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PS-Tools Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows® XP or greater, a compatible modem, and PS-Tools—the Fire•Lite Upload/Download software kit—may serve as a Service Termi- nal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. Version 5.0 firmware supports the following: Primary and Sec- ondary ANN-bus deviOes, AD355 (LiteSpeed), USB port, NAC circuit diagnostics, a hew report has been added to the walk- test that lists untested devices, new device types added: audio telephone type code for ACC 25/50ZST, Photo Supervisory and auto-resettable Drill (non-latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary tele- phone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless othenvise specified, the term MS-9200UDLS is used in this document to refer to both the MS-9200UDLS and the MS-9200UDLS(E) FACPs (Fire Alarm Control Panels). Features Listed to UL standard 864, 9th edition. On-board DACT. Remote site or local USB port upload/download, using PS- Tools. Four (4) Style Y (Class B) NAC circuits, which can be con- verted to four (4) Style Z (Class A) circuits with optional ZNAC-92 converter module. (Up to 6.0 amps total NAC power when using optional XRM-24B.) Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules or LCD-80F, ANN-80 or Legacy ACS Annunciators. ANN-BUS for connection to following optional modules (cannot be used if ACS annunciators are used): - ANN-80(-W) Remote LCD Annunciator - ANN-I/O LED Driver - ANN-S/PG Printer Module - ANN-RLY Relay Module - ANN-LED Annunciator Module - ANN-RLED Annunciator Module alarms only - ROME Relay Option Module Enclosure ACS/TERM: - ACS Annunciators: Up to 32 Legacy ACM Series annun- ciators (ACM-16AT or ACM-32 series). Cannot be used if ANN-BUS devices are used. - Terminal-mode Annunciators: Up to 32 Legacy LCD-80F remote annunciators. DF-60601 Al • 12/07/2010 - Page 1 of 6 / EIA-232 printer/PC interface (variable baud rate) on main circuit board, for use with optional UL-listed printer PRN-6F. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. Detector sensitivity test capability (NFPA 72 compliant). History file with 1,000-event capacity. Maintenance alert warns when smoke detector dust accu- mulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Waterflow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,000 rn). See installation manual for wire tables. NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). The four Class B NACs can be converted to four Class A NACs with optional ZNAC-92 converter module. Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 amps maximum per each NAC circuit. NOTE: Maximum 24VDC system power output is shared among all NAC circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (order programming kit PS-Tools, separately). Upload/ download system programming locally to the MS- 9200UDLS Rev 3 in less than one minute. USB upload/download programming with standard Male-A to Male-B cable. User Interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Alarm Silenced (yellow) System Trouble (yellow) Maintenance/Presignal (yellow) Disabled (yellow) Battery Fault (yellow) Ground Fault (yellow) KEYPAD CONTROLS Acknowledge/Step Alarm Silence Drill System Reset (lamp test) 16-key alpha-numeric pad (similar to telephone keypad) 4 cursor keys Enter Product Line Information MS-9200UDLS: 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-cliiaracter LCD display, sin- gle printed circuit board mounted on chassis, and cabinet. 120 VAC operation. MS-9200UDLSE: Same as MS-92001LIDLS, except with 240 VAC operation. 4XTMF Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. ZNAC-92: Optional converter module which converts four (4) Style Y (Class B) NAC circuits to four (4) Style Z (Class A) cir- cuits. PK-CD Programming software for Winddws®-based PC com- puter (cable not included), available on www.firelite.com. DP-9692: Optional dress panel for MS-9200UDLS Rev 3. TR-CE: Optional trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houses two 55i AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AHI. Requires additional BB- 55F for mounting. BAT Series: Batteries, see data sheet DF-52397. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with MS-9200UDLS Rev 3(E). PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download pro- gramming and updating panel firmware. PRN-6F: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-2/21.11D, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet DF-60407 or DF-52424 for more information.) Page 2 of 6— DF-60601 Al • 12/07/2010 IPBRKT: Mounting kit for IPDACT-2/2UD in common enclo- sure. IPSPLT: V-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. COMPA TIBLE ANNUNCIA TORS ANN-80(-W): LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the FACP LCD dis- play. Recommended wire type is un-shielded. (Basic model is red; order -W version for white; see DF-52417.) ANN-LED: Annunciatbr Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red enclo- sure (see DF-60241). ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241). ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. (See DF- 5243 1.) ROME: 'Relay Option Module Enclosure. Provides one ANN- RLY Relay Module already installed. The ROME Series pro- vides mounting space for one additional Relay Module or one addressable Multi-module. (See Installation Sheet PN 53530.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF-52429.) ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) ACM-BRF: Relay module provids 8 F6rm-C 5.0 amp relays. ACS-LED Zone Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. LCD-80F (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the MS-9200UDLS Rev 3, see the following data sheets (doc- ument numbers) ACM-SRF (DF-5 1555), ACS/ACMSeries (OF- 52378), LDM Series (DP:-51384), LCD-80F (DF-52 185). LITESPEED COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable Jew-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detec- tor with thermal sensor. SD355R: Addressable remote test capable detector for use with D355PL or DNR(W) duct smoke detector housings. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355HT: Fixed high-temperature detector that activates at 190F/88C. AD355(A): Low-profile, intelligent, "Adapt" multi-sensor detec- tor (B350LP base included). BEAM355: Intelligent beam moke detector. BEAM355S: Intelligent beam 'smoke detector with integral sensitivity test. D355PL: lnnovair Flex low-flow non-relay duct-detector hous- ing. SD355R included. DNRW: Innovair Flex low-flow non-elay duct-detector hous- ing, with NEMA-4 rating. Watertight. (Order SD355R sepa- rately.) MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0 (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only IDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. - DF-60601:A1 • 12/07/2010 - Page 3 of 6 CMF-300: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0 (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0 (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface mod- ule mounted inside. 1300: Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 opera- tion). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F., MMF-302-6: Six-zone interface module for compatible conven- tional two-wire detectors. Mount one or two modules in a 1313- 2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-617. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. NOTE: 1) For more information on, Compatible Addressable Devices for use with the MS-9200UDLS Rev 3, see the following data sheets (document numbers): A0355 (DF-52324), BG-I2LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-60379), CMF/CRF Series (DF-52 130), CP355 (DF-52383), D355PL (DF- 52398), H355 Series (DF-52385), /300 (DF-52389), MMF-300 Series/MDF-300 (DF-52 121), MMF-300-10 (DF-52347), MMF- 302-6 (DF-52356), SD355/SD355T (DF-52384). 2) Legacy 300 Series detection devices such as the CP300ICP350, SD300(7)/ SD350(7) and older modules such as the M300, M301, M302, C304, and BG-10LX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard LiteSpeed protocol. Please consult factory for further information on previous 300 Series devices. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel manual for wiring details. Page 4 of 6— DF-60601 Al • 12/07/2010 DF-60601:A1 • 12/07/2010—Page 5 of 7 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits . 1 Addressable device capacity..........................................198 Programmable software zones.........................................99 ACS Annunciators ............................................................32 ANN-bus devices..............................................................16 Electrical Specifications AC Power: MS-9200UDLS Rev 3:120 VAC, 60 Hz, 3.0 amps. MS-9200UDLS Rev 3E: 240 VAC, 5 0 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery charger capacity: 7 AH - 18 AH batteries. Up to two 18 Ah batteries can be housed in the FACP cabinet. Larger batteries require an external battery charger such as the CHG- 75 or CHG-120, and a separate battery cabinet such as the BB-26 or NFS-LBB. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style Y (Class B) for a total of four Style Y (Class B) or with an optional ZNAC-92 module con- verts to four Style Z (Class A) NACs. Maximum signaling cur- rent per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style V (Class B) NAC. Refer to panel documentation and Fire-Lite Device Compatibility Docu- ment for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Special Application Non-resettable Power (24 VDC Nomi- nal): Jumper selectable (JP4) for conversion to resettable power output. Up to 1.0 amp total DC current available from each output. Power-limited. Special Application Resettable Power (24 VDC nominal): Jumper selectable (JP6) for conversion to non-resettable power. Up to 1.0 amp total DC current available. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 300 mA. End-of-Line Resistor: 4.71K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a mini- mum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12" (.30 cm.) deep. Backbox: 19.00' (48.26 cm.) high x 16.65' (42.29 cm.) wide x 5.20 (13;34 cm.) deep. Trim Ring (TA-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 491C/32 - 120°F and at a relative humidity 93% t 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F NFPA Standards The MS-9200UDLS Rev 3 complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be con- nected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). - CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). - OT, PSDN (Other Technologies, Packet-switched Data Network) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9200UDLS Rev 3 control panel. In some cases, certain mod- ules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S624 FM approved CSFM: 7165-0075:0208 MEA: 120-06-E For ULC-listed version, see DF-60599. FireLite® Alarms® is a registered trademark of Honeywell International Inc. Wheelock@ is a registered trademark of and ExcederTM is a trademark of Cooper Notification. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I 0 9001 We try to keep our product information up-to-date and accurate. 9301=1=1 We cannot cover all specific applications or anticipate all requirements. ffilliffffillill & MMUFACT11111ING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 6 of 6— DF-60601 Al • 12/07/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7165-0075:0208 .Page I of 1- CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneywell.com DESIGN: Models MS-9200UD and MS-9200UDLS addressable control units. Local, auxiliary, remote station, central station and proprietary (protected premise). Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *MS.9200UDLS panel also suitable for high-rise application for use with Model ECC-50/100 emergency voice evacuation panel (CSFM #6911-0075:0226). This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev 11-12-13gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID cASTILLO, Program Coordinator Fire Engineering Division df-52417:b • B-90 ANN-80 80-Character LCD Serial Annunciator General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-80s may be connected to the ANN-Bus of each FACP. No programming is required, which saves time during system commissioning. Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill, and Reset. Control switches can be independently enabled or disabled at the FACP. Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP. Enclosure supervised for tamper. System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACP. ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Time-and date display field. Aesthetically pleasing design constructed of durable Lexan. Surface mount directly to wall or to single, double, or 4" square electrical box. Semi-flush mount to single, double, or 4" square electrical box. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight ANN-805 can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Fire•LITsALarms by Honeywell Trouble Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC Current consumption @ 24 VDQ nominal (filtered and non- resettable): 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 491C). Relative humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep. For use indoors in a dry location. All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2424 FM approved (ANN-80) CSFM: 7120-0075:211 MEA: 442-06-E (ANN-80) The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. df-52417:b •05/30/08 - Page 1 of 2 ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-BUS communications circuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-BUS accessory mod- ules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (*) Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. Power wire distance limitation is set by 1.2 volt maximum line drop form source to end of circuit. All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case Current Draw (amps) 22 Gauge 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. 6,000 ft. -6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft, 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172ft. 1,866 ft. 2,953 ft. 0.00 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 - 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN-BUS devices. ANN-BUS and power wiring are supervised and power-limited. = TBI ANN-BUS Device ORDERING OPTIONS: ANN-80: Red, 80 character LCD Annunciator. ANN-80-W: White, 80 character LCD Annunciator. [O1IQ)I1lIJ' 911Mi1U1I 12345678 FACP Wiring to ANN-BUS Device FireLite® Alarms is a registered trademark of Honeywell International Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate: . . We cannot cover all specific applications or anticipate all requirements. CINthUNC & IW4UFACTORINC All specifications are subject to change without notice. QUALITY SYSTEMS - Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105 www.firelite.com Page 2 of 2 - df-52417:b 05/30/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0075:0211 Page 1 of 1 CATEGORY: 7120--ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneywell.com DESIGN: Model ANN-80 and *ANN80W remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control ulilits. Refer to Manufacturers Installation Manual for details. *Rev. 04-28-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff the test results and/or other data but does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division FCPS-24FS6 24 Volt, 6 Amp Power Supply [t- The Fire-Lite FCPS-24FS6(CIE) is a compact, cost-effec- tive, 6-amp remote power supplies with battery charger. The FCPS-24F56(C/E) may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may stand-alone. Primary appli- cations include notification appliance (bell) circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FOPS provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either two Class B (Style Y) and Class A (Style Z, with ZNAC-4 option module) or four class B only. Alternately, the four outputs may be configured as any combination of resettable/non-resettable power outputs (optimal for powering four-wire smoke detec- tors. The FFCPS-24F86(C/E) also contains a battery charger capable of charging up to 7.0 Amp hour batteries. FOPS- 24FS6(C/E) is ULC-listed. NOTE: Unless otherwise specified, the term FCPS-24FS6 used in this document refers to the standard FCPS-24FS6, FCPS- 24FS6C, FCPS-24FS6E Features UL-Listed Notification Appliance Circuit (NAC) synchroniza- tion using System Sensor, Wheelock, or Gentex Com- mander2" appliances. Operates as a "sync-follower" or as a "sync-generator" (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumped perma- nently "ON" (stand-alone mode). Two Class B (Style Y) or Class A (Style Z, with ZNAC-4 module) NACs (circuits 1 & 3) 6-amp full load output, with 3 amps maximum/circuit, in NAC expander mode (UL 864). 4-amp continuous Output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NACs. Selectable earth fault detection. AC trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9 - 32 VDC. Self-contained in compact, locking cabinet - 15"H x 14.5W x 2.75"D (cm: 38.1 H x 36.83W x 6.985D). DF-52301 :A2 • D-025 (& FlreLITeALarms by Honeywell Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FCPS-24FS6: 120 VAC, 60 Hz, 3.2A maximum. FCPS-24F56/E: 240 VAC, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm2) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDC. Trigger Current: 2.0 mA (16-32 V); Per Input: 1.0 mA (9 - 16 V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): - FCPS-24F: 4.0 A maximum. Total short-term current for all outputs (NAC expander mode): - FCPS-24F: 6.0 A maximum. DF-52301 :A2 • 5/17/13 - Page 1 of 4 Secondary Power-(Battery) Charging Circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. Maximum current charge: 250 mA. Maximum battery capacity: 7.0 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A. Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP noti- fication appliance circuits will activate the FCPS when reverse- polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A. Both resettable and non-reset- table power options are available. Resettable outputs are cre- ated by connecting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances" away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. "NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 10,000 feet (3,046 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-24F56 can track (i.e. "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24FS6 is configured (via DIP switch settings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input ter- minal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24F56 is configured (via DIP switch settings) as a "sync generator," the FCPS's sync input terminals are not used. Rather, the FCPS is the originator of the strobe synchro- nization pulses on the FCPS's NAC outputs. In "sync genera- tor" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24FS6 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Page 2 of 4— DF-52301 :A2 • 5/17/13 Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S2424, S1287 ULC Listed: S2424 CSFM Approved: 7315-0076:176 MEA: 387-94E Ordering Information FCPS-24F56: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24FS6 is ULC-listed. FCPS-24FS6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power. BAT-1270: Battery, 12-volt, 7.0 AH (two required). PS-1270: Battery, 12-volt, 7.0 AH (two required). 90286: Optional module mounting kit, is required to install an addressable module on the power supply main circuit board. Style Y NAC or Door Holder Power Output #4 NOTE. All NAC outputs can be converted to Style Z with ZNAC-4 option module. FCPS Trouble Style Y NAC Style Y NAC Style Y NAC Contact Output #3 Output #2 Output #1 Output AC Power INPUT/OUTPUT FUNCTIONS are programmable by SWI DIP switch settings 24 VDC Specific Application Power NAC Control Input #2 (from FACP) NAC Control Input #1 (from FACP) Sync Input FCPS Battery Charger Simplified Block Diagram DF-52301 :A2 • 5/17/13 - Page 3 of 4 000 0 [LJ ® CO Z NIN go 20 Mon C CL i 0 0 OC 0 0 0 g 00 LL CD . u_C 00 8 x ) E>5 C C 8 2 to .51-. I9 C U) - • 8 8 0 0 0 0 CI) (I) 0 0 LOL ID 2(-9--- — —,0.5 I + II I + I + II + + CL Z Oi L L L lii I Id. I n cl oDO Q ________ o e Board Layout System Sensori and FireLite® Alarms are registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. EON BRING I MANUFAMBING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52301:A2 • 5/17/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IQ1 LISTING SERVICE LISTING No. 7315-0075:0206 Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Models FCPS-24FS6 and FCPS-24FS8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listeë's name, product designation, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. NOTE: Rev. 05-06-05JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ftVt operational requirements or installation 'criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID cASTILLO, Program Coordinator Fire Engineering Division Fire Document Box The FDB is the perfect fit to meet the demanding code requirements today. NFPA 72 10.18.2.1.2.8 states that a cabinet must be "prominently labeled 'FIRE ALARM DOCUMENTS'." An internal galvanized sleeve holds the documents safely and securely. The sleeve is easily removable to allow storage of a 1.5" 3 ring binder or other media. The galvanized sleeve also contains 2 hooks for key rings or thumb drives, a place for several business cards, a cutout for a 1.4 Oz. can of test gas and a slot where a standard CD "jewel" case can be stored. Access to the documents is via a high security lock with a 3/4" barrel. Standard Features: Overall Dimensions are: 12" Wide x 13.1" High x 2.25" Deep 3/4" barrel lock to secure door Piano Hinged Door w/Notes Sticker Removable document holder can hold 1" of 8.5" x 11" paperwork Powder Coat Red Finish 16 Gauge CRS construction Embossed: Key Ring Hooks Business Card Holder CD Case Slot 1.4 Oz. can of detector smoke Custom screening with your logo Key Ring Hooks Detector Smoke Business Card Holder CD Jewel Case installation & Inspection Notes ._— --- - REGIS16ED NFPA Made InU.S.A. CQPANY Space Age Electronics, Inc. 2008 ED0447 LTI 0505 Rev.A Oct. 2010 1/2 ADA L Lock wl 314" barrel Space Age Electronics, Inc. www.lsae.com 8110.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! APSPACE AGE ELECTRONICS, INC. Specifications: The Fire Document Box (FDB) shall be constructed of 16 gauge cold rolled steel (CRS); it shall be painted with a durable red powder coat paint. The front door shall be lettered with the words "FIRE ALARM DOCUMENTS" in White indelible letters 1" in height. The door of the FOB shall be locked with a keyed lock, 3/4" barrel. The cabinet shall contain a 16 gauge galvanized CRS sleeve. This sleeve shall allow for the storage of 1" of paper, test and inspection records, manuals and other important documents. The sleeve shall also facilitate the hanging of key rings and thumb drives (for data storage) along with business cards and space for a CD "jewel" case. The unit shall also contain a I .4oz can of smoke detector test gas. Adheared inside the door shall be a "Notes" label for the recording of valuable information such as AHJ approvals, various system codes and the location of hard to find devices. If so desired, the internal sleeve (held in by 2 wing nuts) may be removed and the space used to insert a 1.5" 3 ring binder. ACIBDI NOTES: System Access: System Level Code 5A2813 L110507 RA FDB DO,SI .1. So.,.Ao. ESthflI. 58O,,eu4IR,.d St,t. MADIT4O 003.408.1723 Notes Sticker inside FDB Door Ordering Information: Part # Description SSU00672 FDB Fire Document Box SSU00673 FDB Custom Logo/lock (ask for Form FDI 0498 to order custom box) CKI Replacement 1.4 Oz Test Gas This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0447 LTI 0505 Rev.A 2/2 Space Age Electronics, 'Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFI, IFXIA and IFX/D enclosures. Models ACE-1 1, ACE-12 and ACE-13, *AcE2424 *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff the test results and/or other data but does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division AIR AND MR-'I 00, 200 SERIES in Control MULTI-VOLTAGE CONTROL RELAYS PRODUCT DESCRIPTION The MR Series Multivoltage Control Relays offer SPDT or DPDT 10 Amp resistive contacts which may be operated by one of four input control voltages. A single relay may be energized from a voltage source of 24VDC, 24VAC, I 2OVAC or 230VAC by wiring to appropriate input terminals. 1 Each relay position contains a red LED which indicates the relay coil is energized. Relays may be "snapped apart" from a standard 4 module assembly and used independently. These - Devices are Ideal for applications where local contacts are required for system status, remote - contacts for control of electrical loads and general purpose switching.They are suitable for use with HVAC, Temperature Control, Fire Alarm, Security Energy Management and Lighting Control Systems. FEATURES + Relays may be energized from a voltage source of 18 to 35VDC orVAC, I 2OVAC or 230VAC :• Each relay position contains a red LED, which illuminates when the coil is energized.This provides a time saving device when checking an installed system - no metering is required + Single, dual or triple relay modules may be "snapped apart" from standard 4-position master + DC control inputs are polarized + For continuous duty use at 24VAC, 24VDC, I 2OVAC, or 230VAC •• Available in dust resistant enclosures with LED viewing port(s) + /C versions mounted in enclosures /C/R versions with red covers for NYC and other uses CSFM LISTED . IT versions come complete with track mounting hardware which facilitates installation in standard cabinets MEA ACCEPTED + UL recognized relays rated at 10,000,000 mechanical operations + UL listed as Control Unit Accessory IMRECOGNIZED COMPONENT WIRING (TYPICAL FOR ONE MODULE POSITION) MR-1O1 SPOT CONTACT RESISTIVE 7A @ 30VDC, 10A @ 125VAC, 7A 250VAC INDUCTIVE: .25HP 125/25SVAC (NC), .33 HP 125/250VAC (NO.) RELAY ERG IZI LEO NOTE: DC COIL INPUT IS POLARIZED INPUT CONTROL VOLTAGES 24VDC © 15mA 24VAC 48mA I20VAC 21 MA 230 VAC 19inA Air Products and Controls is a Brand of Apollo America A 25 Corporate Drive HALMA Auburn Hills, Ml 48326 (248) 332-3900 Phone GROUP (888) 332-2241 Toll free COMPANY (248) 332-8807 Fax A/WlA/ nfl-fl rnm MR-201 DPDT CONTACTS RESISTIVE: 7A @ 30VDC, ISA @ I25VAC, 7A @ 250VAC INDUCTIVE: ,25HP 125/250VAC (NC. .33 HP 125050 VAC (NO.) INC C NO NC C NOS RELAY 1000110001 ENERGIZED LED —* 0 ON NOTE: DC COIL INPUT IS = POLARIZED 0 — INPUT CONTROL • 0 18/24 115 230 5 VOLTAGES I 24VDC 6 28mA 24VAC@69mA &C. AC. 120VAC45rnA —0 8 XH 230 VAC @ 381M —0 12 Li Distributed By: PRODUCT SPECIFICATIONS r'r%krrAr'-r --.- KIf'I f's'i III * RAM A ,'Cri I r¼n.1r -1 -_s,j, IV. MODEL MODULE CONFIGURATION MOUNTED MOUNTED COVER FILE FILE FILE NUMBER: POSITIONS PER POSITION H X W X D H X W X D MATERIAL S3403 73-92-E 7300-1004 3.25" (82mm) MR-101/T 1 SPDT 2.125" (54mm) UOXX2 :106 1.50" (38mm) Grey MR-101/C 1 SPDT 5.125" (130mm) ABS-94V0 UOXX Vol. 14 3.125" (79mm) 2.50" (63mm) Plastic UOXX2 UOXX7 ______ _______ :101 Red MR-I 01/dR 1 SPDT ABS-94V0 Vol. 22 Plastic 3.25" (82mm) MR-1041T 4 SPDT 8.50" (215mm) UOXX2 :106 1.50" (38mm) Plated MR-1 04/C 4 SPDT 5.125" (130mm) 18ga UOXX 9.50" (241 mm) 2.50" (63mm) CR S UOXX2 UOXX7 Vol. 14 :101 Red MR-1 04/dR 4 SPDT 18ga CRS 3.25" (82mm) MR-2011T 1 DPDT 2.125" (54mm) UOXX2 :106 1.50" (38mm) Grey MR-201/C 1 DPDT 5.125" (130mm) ABS-94V0 UOXX Vol. 16 3.125" (79mm) 2.50" (63mm) P Plastic UOXX2 _______ :101 1 DPDT UOXX7MR-201/C/R Red ABS-94V0 ______ Vol. 22 Plastic 3.25" (82mm) MR-204/T 4 DPDT 8.5" (215mm) UOXX2 :106 1.50" (38mm) Plated MR-204/C 4 DPDT 5.125" (130mm) 18ga UOXX 9 an,, (241mm) 2.50" (63mm) CRSUOXX2 UOXX7 Vol. 16 :101 MR204/C/R 4 DPDT Red 18ga CRS I COIL VOLTAGE: MR-100: 24(18-35)VDC, 24(18-35)VAC, 120VAC, 230VAC MR-200: 24(18-35)VDC, 24VAC, 120VAC, 230VAC (Pull in voltage: 75% of nominal max. © 25°C; Drop out voltage: 25% of nominal mm. @ 25°C) POLARIZED: DC input only ENERGIZED LED INDICATOR: One per module position CURRENT REQUIREMENT: Per module position: MR-100 Series = 48mA max/ MR-200 Series= 69mA max CONTACT RATINGS: 7A @ 28VDC /10A (NO:1/6HP, NC:1/8HP) © 120VAC / 7A @ 230VAC CONTACT CONSTRUCTION: Dry Form "C" ENVIRONMENTAL: 32°F to 120°F (0°C to 49°C) @ 85% RH (@32°F), Non-condensing, Non-freezing WIRING: Solid or stranded; #14 to #22AWG terminals IT VERSIONS: 3.5" wide, low profile plastic snap track provided with mounting screws IC VERSIONS: Backbox: 18ga CRS, plated with 1/2" conduit knockouts top and bottom *UOX)(Control Unit Accessories, System; 2=Component; 7=Certified for Canada NOTICE: The information contained in this document is intended only as a summary and is subject to change without notice. The products described have specific instructional/installation documentation, which covers various technical, approval, code, limitation and liability information. Copies of this documentation along with any gen- eral product warning and limitation documents, which also contain important information, are provided with the product and are also available from Air Products and Controls Inc. The information contained in all of these documents should be considered before specifying or using the products. Any example applications shown are subject to the most current enforced local/national codes, standards, approvals, certifications, and/or the authority having jurisdiction. All of these resources, as well as the specific manufacturer of any shown or mentioned related equipment, should be consulted prior to any implementation. For further information or assistance concerning the products, contact Air Products and Controls Inc. Air Products and Controls Inc. reserves the right to change any and all documentation without notice. ©Air Products and Controls Inc. 2012 DS-RL-2 D120607 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1004:0101 . - Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Apollo America Inc.25 Corporate Dr., Auburn Hills, MI 48326 Contact: John Schertel (248) 332-3900 Fax (248) 332-8807 Email: John.Schertel@apollo-fire.com - DESIGN: Models MR-101/C, *MR..I 01/C/R, *MR101SSE/C *MR..I 01-SSE/C/R, MR-104/C, *MRI 04/C/R, *MR4045SE/C *MR1 04-SSE/C/R, MR-201/C, MR-201 /C/*R, *MR20I -SSE/C, *MR..201SSE/C/R MR-204/C, MR204/C/*R, *MR204SSE/C *MR.204SSEIC/R PAM-1, PAM-2, PAM-3, PAM-4, PAM-SD, RIC-I, RIC-2, RIC-3, RIC-4, MRRlC301/*C, *MRR1C301/c/R MRRIC305*/C, * MR-RIC-305/C/R, MRRIC40I*/C, *MRRlC.401/C/R MRRIC405*/C and *MRRIc..405/C/R relay modules. *Models MR-ITM/C - and MR-ITM/C/R relay modules (with test mode). Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installatiori instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. NOTE: I. Formerly Air Products and Controls, Inc. *Rev. 04-03-14 gt Tt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52121:E• E-325 MMF-300(A) Series, MDF-300 Addressable Monitor Modules General Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF.300(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire sys- tems. LiteSpeedTM is a communication protocol developed by Fire-Lite Engineering that greatly increases the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. MMF-300(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special (a FlreuTe®ALarms by Honeywell TI MMF-300(A) (Type H) supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPECIFICATIONS Nominal operating voltage: 15 to 3,2 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noricondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF-301(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. DF-52121:E • 07/30/2015— Page 1 of 4 Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems 1415 0 1 ADDRESS 0 1 11 4 LOOP TENS ONES o LU cIo - -J LW 0 cc ca • The MMF-301(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301 (A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-opeh dry-contact devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. MMF-301(A) OPERATION Each MMF-301(A) iuses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports ité type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. MMF-302(A) Interface Module Supports compatible two-wire smoke detectors. Page 2 of 4— DF-52121:E .07/30/2015 Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry °entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The MMF-302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals TIO and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondénsing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style 0 (Class A) IDC circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4(10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424. ULC: S2424. FM Approved. CSFM: 7300-0075:0185. MEA: 72-01-E. Product Line Information NOTE: "A" suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions afld refer to the SLC Wiring Manual, PN51309. Architects/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. DF-52121:E •07/30/2015 - Page 3 of 4 Fire-Lite is a registered trademark and LiteSpeedTM and FireWatchTM are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. b I I EN21116131111118 & WMFACTDMNG All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52121:E •07/3012015 LISTID rc,nM,s, CRF.300(A) Relay Module General The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedTM is a communication protocol developed by Fire'Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01— 159 for MS-9600(A) series panels, 01 - 99 on MS-9200UDLS(A) and MS-9050UD(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The CRF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Open/short supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a control module and a relay module. df-60379:A1 • E-400 (a FlreuTe®ALarms by Honeywell CRF-300(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F(00C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (11.43 cm) high1 x 4° (10.16 cm) wide x 1.250 (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125° (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum voltage Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9A Inductive (LIR=5ms) Coded 30 VDC 0.5 A Inductive (L/R=2m5) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A df-60379:A1 • 08/04/09 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM approved CSFM: 7300-0075:185 MEA: 72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document /56-1190-005 and refer to the SLC Wiring Manual, document 51309. LiteSpeedTM is a trademark and Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. 2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MMiMC11IRING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 - df-60379:A1 • 08/04/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev©Honeywell.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description andf operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire the test results and/or other data but does not make an independent verification Engineering staff of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 3O,2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-61 010:A FMIMFALarms by Honeywell SD365 Installation 5D365(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class B) wiring. SD365R(A) mounts in a 0355PL(A) or DNR(A) /DNRW duct detector housing. Operation Each SD365(A) Series detector uses one possible addresses on the Fire-Iite Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an ES-50X or ES-200X addressable fire alarm control panel. The results of the sensitivity test can be printed off the for record keeping. Specification Voltage range: 15 —32 VDC (peak). Standby current: 200 pA © 24 VDC. Max current: 4.5 mA @ 24 VDC (latched "ON"). Air velocity: 4,000 ft/mm. (20 m/sec.) maximum. Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter. - B300-6: 6.1 (15.6 cm) diameter. - B501: 4' (10.2 cm) diameter. SD365(A) Series Addressable Photoelectric Detectors General The Fire-Lite SD365(A), SD365T(A), and SD365R(A) Series addressable plug-in photoelectric smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contempo- rary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. Exclusively for use with Fire-Lite's addressable fire alarm control panels, the 5D365(A) Series point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, provid- ing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. The SD365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the 5D365T(A) and a remote test capable detec- tor on the SD365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP Two-wire loop connection. Unit uses base for wiring. ADDRESSING Addressable by device. Rotary, decimal addressing: Please refer to the Fire-Lite panel manuals for device capacity. ARCHITECTURE New modern profile for improved aesthetics. Unique single-source design to respond quickly and dependably to a broad range of fires. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. OPERATION Designed to meet UL 268 7th Edition. Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level. Visible LED "blinks" when the unit is addressed (communicating with the fire panel) and latches on in alarm. Low standby current. MECHANICALS Sealed against back pressure. Mounts to: single-gang box, 3.5' (8.89 cm) or 4.0 (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (with or without a mud ring - not included). OPTIONS Remote LED output connection, RA100Z. For a complete list of detector bases see DN-60981. Shipping weight: 3.4 oz. (95 g). DF-61010:A • 4/2/18 - Page 1 of 3 Operating temperature range: SD365(A): 0°C to 50°C (32°F to 122°F); SD365T(A): 0°C to 38°C (32°F to 100°F). SD365R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Relative humidity: 10%-93%, non-condensing. Listings Listings and approvals below apply to the SD365 Series detectors. In some cases, certain detectors may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listed: S1059 CSFM: 7272-0075-0502 FM Approved Product Line Information NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. NOTE: "IV" suffix indicates LiteSpeedo and CLIP device. NOTE: 'A" suffix indicates Canadian version. SD365(A): White, Addressable photoelectric detector; B300-6 base included. LiteSpeed only. SD365(A)-IV: Ivory, Addressable photoelectric detector; B300-6 base included. SD365T(A): White, Same as 5D365 but with thermal element; B300-6 base included. LiteSpeed only. SD365T(A)-IV: Ivory, Same as 5D365 but with thermal element; B300-6 base included. SD365R(A): White, Remote test capable addressable photoelectric detector for use with DNR(A)/DNRW. LiteSpeed only. SD365R(A)-IV: Ivory, Remote test capable addressable photoelec- tric detector; for use with DNR(A)/DNRW. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. 13300-6: White, 6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109 Pending) B300-6-IV: lvory,6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109 Pending) 13300A-6: Same as B300-6, ULC listed. 113300A-6411: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B224B1-IV: Ivory Isolator detector base. (CSFM: 7300-1653:0216 Pending) B224B1A-WH: White, isolator detector base, ULC listing. B224B1A-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses Flash Scan protocol. (CSFM: 7300-1653:0213 Pending) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B200SA-WH: Same as B200S-WH, ULC listing B200SA-IV: Same as 6200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SRA-Wt-I: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base. B501-IV: Ivory color, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for B21OLP(A) base. base. ULJULC listed. (CSFM: 7300-1653:0109 Pending) B501-WHITE-BP: Bulk pack of B501 -WHITE contains 10. B224RB-WH: White, relay base. (CSFM: 7300-1653:0216 Pending) B224RB-IV: Ivory, relay base. (CSFM: 7300-1653:0216 Pending) B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224Bl-WH: White, isolator detector base. (CSFM: 7300- 1653:0216 Pending) DF-61010:A • 4/4/18 —Page 2 of 3 RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B300- 6(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. CK300: Color Kit (includes cover and trim ring), white, 10-pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack. CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack. FireLite® Alarms is a registered trademark of Honeywell International Inc. @2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. S O9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I _____________ All specifications are subject to change without notice. d U I ENGINEERING & MANUFACThRIN QUALITY SYSTEMS For more information, contact Fire.Lite Alarms. Phone: (800)627-3473, FAX: (877) 699-4105. www.firelite.com Page 3 of 3— DF-61010:A • 4/4/18 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0075:0502 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennettHoneywell.com DESIGN: Models 5D365, SD365R and SD365T analog addressable, photoelectric smoke detectors for open area and duct installations. Model SD365T has a complementary heat detector. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed System Sensor base Models B200S and B200SR (CSFM Listing 7300-1653:0213), B200S-LF and B200SR-LF (CSFM Listing 7300-1653:0238), B300-6 and B300-6-IS bases (CSFM Listing 7300-1653:0109), System Sensor duct detector housings Models DNR and DNRW (CSFM listing 3240-1653:0209), Fire-Lite duct detector housing Model D355PL (CSFM listing 3240-0075:0221) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. XLF: 7272-0028:0503 02-01-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-61011:A H365(A) Series Addressable Thermal Detectors General The Fire-Lite H365(A), H365R(A), and H365HT(A) Series address- able plug-in thermal detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the H365(A) Series ideal for both system operation and building design. Exclusively for use with Fire-Lite's addressable fire alarm control panels, the H365(A) Series point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. The H365(A) Series includes fixed temperature, rate-of-rise and high heat fixed temperature detectors that provide effective, intelligent property protection for a variety of applications. Features SLC Loop: Two-wire SLC loop connection. Unit uses base for wiring. ADDRESSING: Addressable by device. - Rotary, decimal addressing. Please refer, to the Fire-Lite panel manuals for device capacity. ARCHITECTURE: Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Integral communications and built-in device-type identification. Built-in tamper resistant feature. Built-in functional test switch activated by external magnet. OPERATION: Fixed temperature model (H365(A)) factory preset to 135°F (57°C). Rate-of-rise model (H365R(A)), 15°F (8.3°C) per minute. High-temperature model (H365HT(A)) factory preset to 190°F (88°C). 360°-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink red in Normal condition and turn on steady red in Alarm. • Visible LEDs "blink" every time the unit is addressed. MECHANICALS: Sealed against back pressure. SEMS screws for wiring of the separate base. Designed for direct-surface or electrical-box mounting. Plugs into separate base for ease of installation and maintenance. Separate base allows interchénge of photoelectric, ionization and thermal sensors. OTHER SYSTEM FEATURES: Remote test feature from the panel. Walk test with address display. Low standby current. (a Flre.tlTeeALarms by Honeywell H365 Options: Remote LED output connection to optional RA100Z remote LED annunciator. Installation H365 Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are per- miffed for Style 4 (Class "B") wiring only. Applications Use thermal detectors for protection of property. Construction These detectors are constructed of fire-resistant plastic. The H365 Series plug-in intelligent thermal detectors are designed to commer- cial standards and offer an attractive appearance. Operation Each H365 Series detector uses one of 159 (panel dependent) pos- sible addresses on the Fire-Lite Signaling Line Circuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when com- manded by the panel. The H365 Series offers features and perfor- mance that represent the latest in thermal detector technology. DF-6101 1:A • 4/23/18 - Page 1 of 3 Specifications Size: 2.0 (5.3 cm) high; base determines diameter. - B300-6: 6.1 (15.6 cm) diameter. - B501: 4" (10.2 cm) diameter. For a complete list of detector bases see DF-60983 Shipping weight: 3.4 oz. (95 g). Operating temperature range: H365, H365R Series: —20°C to 38°C (-4°F to 100°F); H365H: —20°C to 66°C (-4°F to 150°F). Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% — 93% noncondensing. Mounting: B300-6(A) flanged base, included. See "Product Line Information: Intelligent Bases," if using a dif- ferent base. Fixed-temperature setpoint: 135°F (57°C) for the H365 and H365R; 190°F (88°C) for the H365HT. Rate-of-rise detection: responds to greater than 15°F (8.3°C) per minute. ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 200uA © 24 VDC (one communica- tion every 5 seconds with LED enabled). Max current: 4.5 mA © 24 VDC ('ON"). Listings and Approvals Listings and approvals below apply to the H365(A) Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listing: S2101 FM Approved CSFM: 7272-0075-0501 Product Line Information NOTE: '-lV" suffix indicates CLIP and LiteSpeed device. NOTE: "A" suffix indicates Canadian version. H365(A): White, low-profile intelligent 135°F fixed thermal sensor, B300-6 base included. LiteSpeed only. H365(A)-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, B300-6 base included. H365R(A): White, low-profile intelligent rate-of-rise thermal sensor, B300-6 base included. LiteSpeed only. H365R(A)-IV: Ivory, low-profile intelligent rate-of-rise fixed thermal sensor, B300-6 base included. H365HT(A): White, low-profile intelligent 190°F fixed thermal sensor, B300-6 base included. LiteSpeed only. H365HT(A)-IV: Ivory, low-profile intelligent 190°F thermal sensor, B300-6 base included. INTELLIGENT BASES NOTE: For details on intelligent bases, see DF-60059. B300-6: White, 6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109) B300-6-IV: lvory,6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109) B300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UL'ULC listed. (CSFM: 7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. ULJULC listed. (CSFM: 7300-1653:0109,) B501-IV: Ivory color, 4" standard European flangeless mounting base. ULJULC listed. (CSFM: 7300-1653:0109) B501-WHITE-BP: Bulk pack of B501 -WHITE contains 10. B224RB-WH: White, relay base. (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base. (CSFM 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224B1-WH: White, isolator detector base. (CSFM: 7300- 1653:0216) B224B1-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216) B224B1A-WH: White, isolator detector base, ULC listing. B224B1A-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B2005-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses Flash Scan protocol. (CSFM: 7300-1653:0213) B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement:. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the DF-61011:A • 4/23/18 — Page 2 of 3 NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base. TR300-IV: Ivory, replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B300- 6(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. CK300: Color Kit (includes cover and trim ring), white, 10-pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack. CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack. Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. S O9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I 33 All All specifications are subject to change without notice. d U I ENGINEERING & MANUFACTURING QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800)627-3473, FAX: (877) 699-4105. www.firelite.com Page 3 of 3— DF-6101 1:A • 4/23/18 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0075:0501 Page 1 of I CATEGORY: 7270 -- HEAT DETECTOR LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett©Honeywell.com DESIGN: Models H365, H365HT (fixed temperature) and H365R (fixed temperature with Rate-of-Rise) electronic heat detectors. Suffix -IV for ivory color and -BL for black color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Model H365 (fixed temperature): 135°F. Model H365HT (fixed temperature): 190°F. Model H365R (fixed temperature with rate of rise):135°F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Notifier base B7IOLP (CSFM#7300-0028:173); System Sensor bases B510, B2IOLP, B300-6, B300-6-IS (CSFM#7300-1653:0109); 13224131, B224RB (CSFM#7300-1653:0126); 13200S, B200SR (CSFM#7300-1653:0213); B200S-LF, B200SR-LF (CSFM#7300-1653:238); and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. XLF: 7270-0028:0502 02-01-18 gt • This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff the test results and/or other data but does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILL.O, Program Coordinator Fire Engineering Division DF-520130 • E-100 BG-12LX Addressable Manual Pull Station 8 FIreLITeALarms by Honeywell 61-0113—evice The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACP5) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in dawn position and the word ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-la or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4' (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity;: 10% to 93% (noncondensing) For use indoors in a dry location Installation The BG-1 2LX will moiiint semi-flush into a single-gang, double- gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-b 0 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (8G12TR) may be used. The BG12T1R is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 —159 with Breakaway Tab removed for MS-9600 Series, 1 - 99 and MS-9200UDLS, 1 - 50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed DF-52013:D.4/13/2012—Page 1of2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status UL/ULC Listed: S711 (listed for Canadian and non-Cana- dian applications). NIEA: 67-02-E. CSFM: 7150-0075:0184. FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. FireLite® Alarms® is a registered trademark of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. ENDINEMING & MAN VMCIlIRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52013:1) • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneyweIl.com DESIGN: Models BG-12, BG-125, BG-I2NC, BG-12W, BG-I2LW, BG-12WP, BG-I2LWP, BG-12L, BG-12LX, BG-I2LA, BG-12PS, BG-12LSP, BG-I2SP, BG-I2LR, BG-12LRA, BG-I2LAO, BG-I2LAOB, BG-12-LO, BG-12LOB, BG-I2LPS, BG-I2LPSP, BG-12SL, UT-PSI and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-12LW and BG-12LWP are intended for outdoor use when installed with Model WP-I0 back box. Models BG-LAOB and BG-I2LOB are intended for outdoor use when installed with Model WBB or WP-1 0 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID cASTILLO, Program Coordinator Fire Engineering Division SYSTEM SENSOR Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. )l Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 tor ALERT models 7135-1653:0503 3057383 AVDS868.02 • 12/01/2017 • Papa 3 L-Series Specifications _______ ______ • '; 1 General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync'Circuit°° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module; 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync'Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. T 77 7_77777' - . ................ Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Rang& 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (Including lens) 6.8' diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9' diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02 • 12/01/2017 • Page 2 UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 87 41 60 Range 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded Hiah 42 43 54 UL Max. Current Draw (mA DC Input RMS), Ceiling 8-17.5 Volts 15cd 30cd Horn Strobe, Candela Range 16-33 Volts 15cd 30cd (15-177 cd) 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02 • 12/01/207 • Page 3 2.47' (62.7 mm) 1.37 (34.8 mm) 6.83 dh (173n r— (64 mm) 6.92' (175. L-Series Dimensions A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box -01 .I1 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications". 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box t! lr••li ;Q.:-: Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White 1'YtS'TE'Ii!ñ1 3825 Ohio Avenue • St. Charles, IL 60174 1 ©2ol7 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com Phone: 800-SENSOR2 • Fax: 630-377-6495 tsr current product informaon, including the latest version 01 this data sheet. AVDS868-02 • 12/01/2017 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire the test results and/or other data but does not make an independent verification Engineering staff of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: RegiJIated 12 VDC setting: 8-17.5 VDC RegUlated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL:. Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID cASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. KireyevhoneywelI.com DESIGN: System Sensor Indoor 2-wire and *4..wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *134WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff the test results and/or other data but does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI2OKL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VOC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID cASTILLO, Program Coordinator Fire Engineering Division Agency Listings SIGNAUNO (9 LISTED <zEi> S401 1 (chimes, horn strobes, horns) APPROVED S3593 (outdoor and alert strobes) 3023572 0 MEh4i 7300-1653:187 (outdoor Strobes) approved 7125-1653:188 (horn strobes, chime strobes) M5A452-05-E 7135-1653:189 (horns, chimes) SYSTEM SENSOR® Outdoor Selectable. Output Strobes and Horn Strobes for Ceiling Applications V o 05$ y S iv"-41 SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from -40°F to 151°F. Like the entire SpectrAlert Advance line, outdoor strobes and horn strobes for ceiling applications include a variety of features that increase application flexibility and simplify installation. First, field- selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Plastic and metal weatherproof back boxes come with 34-inch top and bottom conduit entries and 34-inch knock-outs at the back. Three screw-in NPT plugs with 0-ring gaskets for a watertight seal is included with each back box. SpectrA lertO Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features Weatherproof NEMA 4X, 1P56 rated Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field-selectable candela settings: 15,15/75,30,75,95,110,115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from -40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting SpectrAlert Advance Outdoor Strobe, and Horn Strobe Specifications ig 1 General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync*CircUitTm Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40 and 151 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1638 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1638 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four- wire products, the strobe shall be powered independently of the sounder. The horn strobe on a 2-wire model shall work on a non-coded power supply. The horn on 4-wire horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor listed per UL. The horn strobe shall be suitable for use in wet environments. . .'. ., Operating Temperature —40°F to 151°F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range with MDL3 Sync Module 8.5 to 17.5V (12 V nominal) or 16.5 to 33V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Strobe! Horn Strobe Dimensions 5.6"L x 4.7"W x 1.3"D (142 mm Lx 119 mm W x 33 mm D) Strobe! Horn Strobe Dimensions with Back Box 5.6"L x 4.7"W x 1.3"D (142 mm Lx 119 mm W x 33 mm D) Ceiling-Mount Weatherproof Back Box Dimensions 7.1" diameter x 2.0" high (180 mm diameter x 51 mm high) Notes: Full Wave Rectified (RNR) voltage is a non-regulated, time-varying power source that is used on some .power supply and panel outputs. Products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS 11401 UL Current Draw Data Candela 8-17.5 Volts DC FWR 16-33 Volts DC FWR Standard 15 123 128 66 71 Candela 15/75 142 148 77 81 Range 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela 150 NA NA 246 220 Range 177 NA NA 281 251 185 NA NA 286 258 Sound Pattern dB 8-17.5 Volts DC FWR 16-33 Volts DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 DC Input 8-17.5 Volts 15 15/75 16-33 Volts 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low UL Max. Current Draw (rnA DC Input 132 RMS), 2-Wire 16-33 Volts 135 150 154 Horn:Str6be, 80 High 177 Candela 185 90 105 Range (135-185 cd) FWR Input 161 184 16-33 Volts 135 150 202 177 211 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Horn Tones and Sound Output Data Horn Strobe Output (dBA) 8-17.5 16-33 _ 24-Volt Nominal IStrobe TOutput Ij) Listed Candela Candela rating at -40°F 15 Do not use below 32°F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 150 177 1177 185 1185 awnun oounu YMIIO V,Ju La flCVCI MCI CU It flU Position Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- High 82 82 88 88 93 92 100 100 Temporal 5 Non- Medium Temporal 78 78 85 85 90 90 98 98 6 Non- Low Temporal 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tsettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS11401 SpectrAlert Advance Diagrams Ceiling-Mount Horn Strobes Ceiling Plastic Weatherproof Back Box Ceiling-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information 00,777 7 Horn Strobes PC2RK 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) PC2RHK 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) PC2WK 2-Wire, Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) PC2WHK 2-Wire, Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Ceiling Strobes SCRK Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SCRHK Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SCWK Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SCWHK Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Accessories SA-WBBC Red, Metal Weatherproof Back Box SA-WBBCW White, Metal Weatherproof Back Box MP12OK Notes: "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High ca" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing outdoor units, both the device and back box must be replaced. iSTiáYi1 Al 3825 Ohio Avenue • St. Charles, IL 60174 ©2O15SysternSensor. Product specrhcahons subject to change without notice. Visit systemse550r.com Phone: 800-SENSOR2 • Fax: 630-377-6495 AvD5t14o2.02/15 for current product ntormation, including the latest version of this data sheet. IN CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0187 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.KireyevhoneyweIl.com DESIGN: Models SWK, SWHK, SCWK, SCWHK, SRK, SRHK, SCRK and SCRHK strobe lights intended for indoor or outdoor use and may be mounted on the wall or the ceiling. These strobe lights are suitable for outdoor use at an operating temperature range of -40°F to 150°F (-40°C to 660C)* rating and are NEMA 4X rated when used with the Listed models SA-WBB (wall), SA-WBBW (Wall) or the model SA-WBBC (ceiling), SA-WBBCW (Ceiling) weatherproof back boxes. May be followed by suffix -P for plain housing with no lettering. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for general signaling. For indoor or outdoor use. Refer to listee's Installation Instruction Manual for details. NOTE: Not approved for public mode and not to be used as an evacuation signal for the hearing impaired. *Corrected 07-22-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix 'K' indicating indoor or outdoor use, or may be followed by suffix "P" for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30,2019 Authorized By: DAVID cASTILLO, Program Coordinator Fire Engineering Division