Loading...
HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; FPC2022-0186hty of PERMIT REPORT Carlsbad Print Date: 07/17/2024 Permit No: FPC2022-0186 Job Address: 5781 VAN ALLEN WAY, CARLSBAD, CA 92008-7321 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121304400 Track #: Applied: 10/04/2022 Valuation: $697,882.55 Lot #: Issued: 10/19/2022 Occupancy Group: Project U: Finaled Close Out: 07/17/2024 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check U: INSPECTOR: Robinson, Jarrod Plan Check U: Project Title: Description: THERMO FISHER GOLD RUSH CP 2 -SPRINKLER TI (74 HEADS, 2 RISERS) Applicant: FPContractor: WESTERN FIRE PROTECTION INC WESTERN FIRE PROTECTION INC MARIO MACK 13630 DANIELSON ST 13630 DANIELSON ST POWAY, CA 92064-6830 POWAY, CA 92064-6830 (858) 513-4949 (858) 513-4949 FEE AMOUNT FIRE NFPA 13 or 13R System 7-100 heads $654.00 Total Fees: $654.00 Total Payments To Date: $654.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Western Fire Protection Inc. ThermoFis her Scientific Gold Rush Office T.I. - CP-2 5781 Van Allen Way Carlsbad, CA 92008 Automatic Wet Fire Sprinkler System 21-3596-02 Product Submittal 9-30-2022 13630 Danielson Street • Poway, CA 92064 • Phone: (858) 513-4949 • Fax: (858) 513-1322 SECTION DESCRIPTION CONTENTS 1. SPRINKLERS VICTAULIC FL-QR SEMI-RECESSED PENDENT V2708 VICTAULIC FL-SR UPRIGHT V3401 VICATULIC FL-QR UPRIGHT V2704 VICTAULIC VICFLEX SERIES AH2 BRAIDED FLEXIBLE HOSE 2. PIPE & FITTINGS BULL MOOSE SCH 10 & SCH 40 BLACK STEEL PIPE WHEATLAND SCH 10 & SCH 40 BLACK STEEL PIPE VICTAULIC FIRELOCK FITTINGS VICTAULIC FIRELOCK RIGID COUPLING #009N VICTAULIC FIRELOCK RIGID COUPLING #005H VICTAULIC FIRELOCK FLEXIBLE COUPLING #75 VICTAULIC STYLE 920 MECHANICAL-T BOLTED BRANCH OUTLET VICTAULIC STYLE 922 MECHANICAL-T BOLTED BRANCH OUTLET MERIT WELDED OUTLET FITTINGS SMITH COOPER DUCTILE IRON THREADED FITTINGS 3. HANGERS TOLCO FIG 200 ADJUSTABLE BAND HANGER TOLCO FIG 25 SURGE RESTRAINER TOLCO FIG 100 ALL THREAD ROD ERICO CADDY BRANCH LINE RESTRAINT TOLCO FIG 58 THREADED SIDE BEAM BRACKET DeWALT SUSPENDER DUAL-DIRECTIONAL DeWALT SNAKE 4. MISCELLANEOUS ARGCO FIRE SPRINKLER SPARE HEADBOX ARGCO FIRE SPRINKLER IDENTIFICATION SIGNS MATERIALS MAY BE SUBSTITUTED WITH LISTED EQUAL DUE TO PRODUCT AVAILABILITY* Standard Coverage, Quick Response Upright, Pendent and Recessed Pendent Sprinklers .4tauiic K2.8 (4.0), K4.2 (6.1) K5.6 (8. 1) K8.0 (11.5) 41.01 1.0 PRODUCT DESCRIPTION QUICK RESPONSE UPRIGHT SPRINKLERS SIN V2815 V4215 V2704 V3402 ORIENTATION UPRIGHT UPRIGHT UPRIGHT UPRIGHT K-FACTOR' 2.81mpJ4.05.I. 4.2lmp./6.1 5.1. 5.61rnpJ8.1S.I. 8.0tmp./11.55.I. CONNECTION ½' NPT/115mm BSPT ½" NPT/15mm BSPT ½' NPT/15mm BSPTIIGS 3/4" NPT/20mm BSPT/IGS MAX. WORKING PRESSURE 175 psi/1200 kPa 175 psi/1 200 kPa 175 psi/1200 kPa cULus 250 psi /1725 kPa 175 110 kPa GLOBE RE-DESIGNATION GL2815 GL4215 - I - GLOBE EQUIVALENT I - - GL5615 GL8118 QUICK RESPONSE PENDENT SPRINKLERS SIN V2801 V4201 V2708 V3406 ORIENTATION PENDENT PENDENT PENDENT PENDENT K-FACTOR1 2.8 ImpJ4.0 S.I. 4.2 Impi6.1 S.I. 5.6 ImpJ8.1 S.I. 8.0 Impi1 1.5 5.1. CONNECTION ½" NPT/15mm BSPT ½" NPT/15mm BSPT ½" NPT/lsmm BSPT/IGS 3/4" NPT/20mm BSPT/IGS MAX. WORKING PRESSURE 175 psi /1200 kPa 175 psi /1200 kPa 175 psi /1200 kPa cULus 250 psi/1 725 kPa 175 psi/1 200 kPa GLOBE RE-DESIGNATION GL2801 GL4201 - - GLOBE EQUIVALENT - - GL5601 GL8101 QUICK RESPONSE RECESSED PENDENT SPRINKLERS SIN V2801 V4201 tV2708 V3406 ORIENTATION PENDENT PENDENT PENDENT PENDENT K-FACTOR' 2.81mpi4.0S.I. 4.2lmp./6.1 S.I. 5.61mpj8.1S.I. 8.olmp./11.55.I. CONNECTION ½" NPT/15mm BSPT ½" NPT/lsmm BSPT ½" NPT/15mm BSPT/IGS 1/4" NPT/20mm BSPT/IGS MAX. WORKING PRESSURE 175 psi/1 200 kPa 175 psi/1 200 kPa 175 psi/1 200 kPa cULus 250 psi/1 725 kPa 175 psi/i 200 kPa ESCUTCHEON Recessed Recessed Recessed Recessed GLOBE RE-DESIGNATION GL2801 GL4201 - I - GLOBE EQUIVALENT - - GL5601 GL8101 AVAILABLE GUARDS/SHIELDS SPRINKLER V28 V42 V27 V34 Upright U U Pendent U AVAILABLE WRENCHES SPRINKLER V56-2 Recessed V56 Open End V27-2 Recessed V27 Open End V34-2 Recessed V34 Open End 3/6 Hex-Bit V2815 and V4215 V2707 and V2704 V3402 V2801, and V4201 V2706 and V2708 V3406 Factory Hydrostatic Test: 100% @ 500 psi/3447 kPa/34 bar Mm. Operating Pressure: UL/FM: 7 psi/48 kPa/.5 bar VdS: 5 psi/35 kPa/.35 bar (Upright only) Temperature Rating: See tables in section 2.0 1 For K-Factor when pressure is measured in bar, multiply S.I. units by 100. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. tnm 41.01 16343 Rev 0 Updated 07/2022 © 2022 Victaulic company. All rights reserved. 1 victaulic.com 2.0 CERTIFICATION/LISTINGS C<p( (E UK H (~~) UPRIGHT APPROVALS/LISTINGS SIN V2815 V4215 (V2704 V3402 Nominal K Factor Imperial 2.8 4.2 5.6 8.0 Nominal K Factor 5.1.2 4.0 6.1 8.1 11.5 Orientation UPRIGHT UPRIGHT UPRIGHT UPRIGHT Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 135°F/57°C 135°F157°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C cULus 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 286°F/141°C 286'F/1 41-C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C FM - - 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C LPCB - - 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C CE, UKCA - - . 175°F/79°C . 175°F/79°C 200°F/93°C 200°F/93°C 286'F/1 41'C 286°F/1 41°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C VdS - - 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C CCC 155°F/68°C 155°F/68°C K-ZSTZ - - 286°F/141°C For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. PENDENT APPROVALS/LISTINGS SIN V2801 V4201 V2708 V3406 Nominal K Factor Imperial 2.8 4.2 5.6 8.0 Nominal K Factor 5.1.2 4.0 6.1 8.1 11.5 Orientation PENDENT PENDENT PENDENT PENDENT Escutcheon Flush/Extended Flush/Extended Flush/Extended Flush/Extended Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C cULus 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C FM - - 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C / 286°F/141°C 286°F/141°C CCC 155°F/68°C 155°F/68°C K-ZSTX - 286°F/141°C 2 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. NOTES Listings and approval as-of printing. Where cULus Listed, Polyester and VC-250 Coatings Listed as Corrosion Resistant (V3402 with VC-250 Only) Where FM Approved, VC-250 Coating Approved as Corrosion Resistant New York City Acceptance - All UL Listed and/or FM Approved sprinklers acceptable to NYC per section 28-113 of the Administrative Code and the 01CR Rule 41.01 16343 Rev D Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 2 ',4taLJIic victaulic.com 2.0 CERTIFICATION/LISTINGS (CONTINUED) RECESSED PENDENT APPROVALS/LISTINGS SIN V2801 V4201 V2708 V3406 Nominal K Factor Imperial 2.8 4.2 5.6 8.0 Nominal K Factor 5.1.2 4.0 6.1 8.1 11.5 Orientation PENDENT PENDENT PENDENT PENDENT Escutcheon Recessed Recessed - Recessed Recessed Approved Temperature Ratings F°IC° 135°F157°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F 57°C 155°F/68°C cULus 175°F/79°C 175°F/79°C 155°F'68°C / 175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/1 41°C 286°F/1 41 °C 200°F/93°C 286'F/1 41'C FM 135°F/57°C 135°F157°C WITH 1/i" ADJUSTMENT - - 155F/68C 155F/68C ESCUTCHEON ONLY 175'F/79'C 175*F/79'C 200°F/93°C 200°F193°C CCC 155°F/68°C -ZSTX - - 286 F/141 286°F/141°C 2 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. NOTES Listings and approval as of printing. Where cULus Listed, Polyester and VC-250 Coatings Listed as Corrosion Resistant (V3402 with VC-250 Only) Where FM Approved, VC-250 Coating Approved as Corrosion Resistant New York City Acceptance - All UL Listed and/or FM Approved sprinklers acceptable to NYC per section 28-113 of the Administrative Code and the 01CR Rule. 41.01 16343 Rev D Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victau I ic .com 3 Lictaulicr victaulic.com 3.0 SPECIFICATIONS - MATERIAL Deflector: Bronze Bulb Nominal Diameter: 3.0mm /13 mm inal make-in Load Screw: Bronze Pip Cap: Bronze Frame Lodgement spring Spring Seal: PTFE coated Beryllium nickel alloy Y t63 Pip cap and / Frame: Brass spring seal Bulb m Lodgement Spring: Stainless steel Load screw Deflector Installation Wrench: Ductile iron Sprinkler Frame Finishes: I 33mm1 Plain brass Chrome plated 17A6'7 White polyester painted34 Deflector 37 mm Flat black polyester painted34 Load screw Bulb Custom polyester painted34 Pip cap and VC-2505 spring seat Lodgement spring mm 63 Not available on the Intermediate Level Style Pendent. Frame UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. NOTE ½713 mm Nominal make-in For cabinets and other accessories refer to separate sheet. 7A6Il 1 mm Nominal make-in lI15i Deflector 40 mm Lodgement spring Load screw Pip cap and Bulb spring seal 25A67 Pip cap and 21/4 / Bulb 58 mm spring seal Load screw Lodgement srin 7mm Frame Frame - Deflector mm 31 mm Nominal make-in Deflector Deflector 116 / 37mm Load screw Bulb Load screw Bulb Pip cap and Pip cap and '/ spring seal _______ T63mm spring 63 / spring seal Lodgement 2½/ mm Lodgement spring Frame _________Frame /l3mm L Nominal make-in 1/2713 mm Nominal make-in 41.01 16343 Rev D Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 4 \,taUIiC victauIiccom 4.0 DIMENSIONS 234760 mm 2/51 mm Hole in ceiling /8/22 mm Max. ((3/4" Ad).) /8'7l6 mm Max. (½' Adj.) 1473mm Mm. Typical ceiling 13/a"/34 mm Mm. (½' Adj.) 114729mm Mm ((3/4" Ad)) 1 ~\W) Finished surface 17/s"/47 mm Max. 2146775 mm 21/8760 mm 2/51 mm - Hole in ceiling 7/8722 mm Max. (1/4" Adj.) 1/8716 mm Max. (½" Ad).) W/3 mm Mm. Typical ceiling Finished surface 17/8"/47 mm Max 2"A6775 mm 1Y8729 mm Mm. (1/4" Ad).) 13/a"/34 mm Mm. (½' Ad).). 2-Y8760 mm 2751 mm -' Hole in ceiling 1/25 mm Max. (3/4" Ad).) 3W/19 mm Max. (½" Ad).) 1/476 mm Mm. 41'~~ Typical ceiling 15Ao"/24 mm Min. (3/4" Adj.) 13A6730 mm Mn (½" Adj) I Finished surface 1146/43 mm Max. ~W) 2'5A6"/75 mm 41.01 16343 Rev D Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5 \t9uIic victaulic.com 5.0 PERFORMANCE Sprinkler is to be installed and designed as per NFPA, FM Datasheets, or any local standards. 6.0 NOTIFICATIONS AL WARNING _____ • Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressur- ized and drained immediately prior to installation, removal, adjust- ment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. - These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Ratings: All glass bulbs are rated for temperatures from -67°F/-55°C to those shown in the table below. 1-40: Victaulic FireLockiM Automatic Sprinklers Installation and Maintenance Instructions I-V9: Style V9 Victaulic FireLockrM IGSTM lnstallationReadynM Sprinkler Coupling Installation Instructions User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as lathe suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions at sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement at any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products lobe installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 41.01 16343 Rev 0 Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com ictsulicr Standard Coverage, Standard Response Upright Pendent and Recessed Pendent Sprinklers, A ______ K2.8 K4.2 (6.1), K5.6 (8.1)' K8.0 (11.5)) 41.51 1.0 PRODUCT DESCRIPTION STANDARD RESPONSE UPRIGHT SPRINKLERS SIN V2861 V4261 V2703 V3401 ORIENTATION UPRIGHT UPRIGHT UPRIGHT UPRIGHT K-FACTOR' 2.8 Impf4.0 S.I. 4.2Impi6.1 S.I. 5.61mp./8.1 S.I. 8.0 Imp./11.5 S.I. CONNECTION ½' NPT/15mm BSPT ½" NPT/15mm BSPT ½" NPT/15mm BSPT/IGS 3/4' NPT/20mm BSPT/IGS MAX. WORKING PRESSURE 175 psi (1200 kPa) 175 psi (1200 kPa) 175 psi (11200 kPa) cULus2 psi (1725 kPa) 175 psi (1200 kPa) GLOBE RE-DESIGNATION GL2861 GL4261 GLOBE EQUIVALENT GL5661 GL8164 STANDARD RESPONSE PENDENT SPRINKLERS SIN V2851 V4251 V2707 V3405 ORIENTATION PENDENT PENDENT PENDENT PENDENT K-FACTOR' 2.8lmp./4.0S.I. 4.21mpi6.1 S.I. 5.61rnp./8.1S.I. 8.0lmpil1.55.I. CONNECTION ½" NPT/15mm BSPT ½" NPT/15mm BSPT ½" NPT/lsmm BSPT/IGS 3/4" NPT/20mm BSPT/IGS MAX. WORKING PRESSURE 175 psi (1200 kPa) 175 psi (1200 kPa) cULu7s52 psi psi (1725 kPa) (1200 kPa) 175 psi (1200 kPa) GLOBE RE-DESIGNATION GL2851 GL4251 _____________________ GLOBE EQUIVALENT GL5651 I GL8156 STANDARD RESPONSE RECESSED PENDENT SPRINKLERS SIN V2851 V4251 V2707 V3405 ORIENTATION PENDENT PENDENT PENDENT PENDENT K-FACTOR' 2.8 Impj4.0 S.I. 4.21mpj6.1 SI. 5.61mpi8.1 S.I. 8.0 Imp./11.5 5.1. CONNECTION ½"NPT/lSmmBSPT ½"NPT/15mmBSPT ½"NPT/lSmmBSPT 3/4"NPT/20mmBSPT MAX. WORKING PRESSURE 175 psi (1200 kPa) 175 psi (1200 kPa) 175 psi (1200 kPa) cULus 250 psi (1725 kPa) 175 psi (1200 kPa) ESCUTCHEON Recessed Recessed Recessed Recessed GLOBE RE-DESIGNATION GL2851 GL4251 GLOBE EQUIVALENT GL5651 GL8156 AVAILABLE GUARDS/SHIELDS SPRINKLER V28 V42 V27 V34 UPRIGHT PENDENT ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.Com 41.51 16372 Rev B Updated 07/2022 © 2022 Victaulic Company. All rights reserved. 1 ________________ victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) AVAILABLE WRENCHES SPRINKLER V56-2 Recessed V56 Open End V27-2 Recessed V27 Open End V34-2 Recessed V34 Open End 'M Hex-Bit V2861 and V4261 V2703 and V2707 V3401 V2851 and V4251 V2707 V3405 Factory Hydrostatic Test: 100% @ 500 psi/3447 kPaI34 bar Mm. Operating Pressure: UL/FM: 7psi/48 kPa/.5 bar VdS: 5ps1/35 kPa/.35 bar (Upright only) Temperature Rating: See tables in section 2.0 1 For K-Factor when pressure is measured in bar, multiply S.I. units by 10.0. 41.51 16372 Rev B Updated 07/2022 0 2022 Victaulic company. All rights reserved. victaulic.com 2 \/taUIiC 3 41.51 16372 Rev B Updated 07/2022 © 2022 Victaulic Company. All rights reserved. ,it-hii ilim mnm \htauI i c° uie°fiiIir mm 2.0 CERTIFICATION/LISTINGS c®<& (E UK rv—ds] © USTED CR UPRIGHT APPROVALS/LISTINGS SIN V2861 V4261 V2703 lV34Oi Nominal K Factor Imperial 2.8 4.2 5.6 8.0 -- Nominal K Factor SI.2 4.0 6.1 8.1 11.5 Orientation UPRIGHT UPRIGHT - UPRIGHT UPRIGHT Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C cULus 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 286°F/141°C 200°F/93°C 286°F/141°C 286°F/141°C 360'F/1 82'C 286°F/141°C 360°F/1 82°C 360°F/1 82°C 500°F/260°C 360°F/1 82°C 135°F157°C 135°F/57°C 155°F/68°C 155°F/68°C FM - 175°F/79°C 175°F/79°C - 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C - 3607/1 82°C 360°F/1 82°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C LPCB 175°F/79°C 175°F/79°C - 200°F/93°C 200°F/93°C 286°F/141°C 286°F/1 41 °C 360°F/1 82°C 360°F/1 82°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C CE, UKCA - - 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 286°F/1 41°C 286°F/1 41°C 135°F/57°C 135°F/57°C i 55°F/68°C i 55°F/68°C VdS - - 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 286°F/1 41°C 286°F/1 41°C 155°F/68°C 155°F/68°C CCC 175°F/79°C - ZSTZ-15 - - 200°F/93°C - 286°F/141°C 286°F/141°C 2 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. NOTES Listings and approval as of printing. Where cULus Listed, Polyester and VC-250 Coatings Listed as Corrosion Resistant (V3401 with VC-250 Only) Where FM Approved, VC-250 Coating Approved as Corrosion Resistant New York City Acceptance - All UL Listed and/or FM Approved sprinklers acceptable to NYC per section 28-113 of the Administrative Code and the 01CR Rule. 41.51 16372 Rev B Updated 07/2022 © 2022 Victaulic Company. All rights reserved: s,irfi.Iir mm 51 virtnilic mm 2.0 CERTIFICATION/LISTINGS (CONTINUED) C(P (E UK t © PENDENT APPROVALS/LISTINGS SIN V2851 V4251 V2707 V3405 Nominal K Factor Imperial 28 42 56 80 Nominal K Factor 5.1.2 4.0 6.1 8.1 11.5 Orientation PENDENT PENDENT PENDENT PENDENT Escutcheon FlushlExtended FlushlExtended FlushlExtended FlushlExtended Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 1 155°F/68°C cULus 175°F/79°C 175°F/79°C 175 175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/1 41°C 286°F/141°C 286°F/1 41 *C 360°F/1 82°C 360°F/1 82°C 60°F/i 82°C 360°F/1 82°C 500°F/260°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C FM - 175°F/79°C i 75°F/79°C - 200°F/93°C 200°F/93°C 286°F/1 41°C 286°F/1 41°C 3607/1 82°C 360°F/1 82°C 155°F/68°C 155°F/68°C CCC i 75°F/79°C - ZSTX-15. - - 200°F/93°C 286°F/1 41°C 286°F/141°C RECESSED PENDENT APPROVALS/LISTINGS SIN V2851 V4251 V2707 V3405 Nominal K Factor Imperial 2.8 4.2 5.6 8.0 Nominal K Factor Sj.2 4.0 6.1 - 8.1 11.5 Orientation PENDENT PENDENT PENDENT PENDENT Escutcheon Recessed Recessed Recessed Recessed Approved Temperature Ratings F°IC° 135°F/57°C 135°F/57°C 155F/68:C 135°F/57°C 135°F/57°C cULus 175 F/79 C 155°F/68:C 175 F/79 C i 55°F/68°C i 55°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 175°F/79°C 286°F/1 41°C 286°F/1 41°C 200°F/93°C 200°F/93°C FM 135°F/57°C 135°F/57°C With ½ Adjustment - - 155°F/68°C 155°F/68°C Escutcheon Only 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 155°F/68°C 155°F/68°C CCC i 75°F/79°C - ZSTX-15 - 200°F/93°C - 286°F/141 °C 286°F/1 41°C 2 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. NOTES Listings and approval as of printing. Where CULIJS Listed, Polyester and VC-250 Coatings Listed as Corrosion Resistant (V3401 with VC-250 Only) Where FM Approved, VC-250 Coating Approved as Corrosion Resistant New York City Acceptance - All UL Listed and/or FM Approved sprinklers acceptable to NYC per section 28-113 of the Administrative Code and the 01CR Rule. victaulic.com 3.0 SPECIFICATIONS - MATERIAL Deflector: Bronze 1°A6"! Bulb Nominal Diameter: 5.0mm Deflector 40mm Load Screw: Bronze Load screw Pip Cap: Bronze Bulb Pip cap and 21/4 / Spring Seal: PTFE coated Beryllium nickel alloy spring seal 7 mm Lodgement spring Frame: Brass Frame Lodgement Spring: Stainless steel 7A6'Yll mm Installation Wrench: Ductile iron Nominal make-in Sprinkler Frame Finishes: V2861, V4261 Plain brass Chrome plated White polyester painted3 4 1/l6/ 37 mm Flat black polyester painted34 Deflector Custom polyester painted34 Load screw Bulb r60 VC-2505 Pip cap and '! Not available on the Intermediate Level Style Pendent. spring seal m Lodgement spring UL Listed for corrosion resistance. Frame UL Listed and FM Approved for corrosion resistance. NOTE mm - 7A6'Yl 1 Ndmirial make-in For cabinets and other accessories refer to separate sheet. V2703 17A6! Deflector 37 mm 7Ao/11 mm Nominal make-in Load screw Bulb Lodgement spring Pip cap and sp Z ring seal Pip cap and spring seal 1/2 Lodgement spring 63mm )liI 58 mm Frame L 1/2713 mm Nominal make-in V3401 ,1o'711 mm JNominal make-in Frame I Lodgement spring Pip cap and spring seal 60 mm Bulb Load screw Deflector VV 25 mm V2707 Luau 5LCW Frame Deflector 31 mm V2851, V4251 ½"/13 mm -- - [Nominal make-in Frame Lodgement spring - 63 mm 2½"! Pip cap and spring seal Bulb I Load screw Deflector 11/167 33 mm V3405 41.51 16372 Rev B Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5 XIkctauhcr victaulic.com 4.0 DIMENSIONS 2%'/60 mm 2751 mm - Hole in ceiling /8"/22 mm Max. (3%' Adj.) /8716 mm Max. (½ Adj.) W/3 mm Mm. Typical ceiling Ii Finished surface 17/8747 mm Max 1Y8"/29 mm Mm. (3/4" Adj.) 1/8"/34 mm Mm. (½" Ad).). - 25A6775 mm - V2851, V4251 2%'76O mm - 2/51 mm - Hole in ceiling 1725 mm Max. (3%" Ad).) 3/4719 mm Max. (½" Adj.) 1/,/6 mm Mm. Typical ceiling Finished surface 13A6"/30 mm Mm. (½" Ad).) 5A6"/24 mm Mm. (34" Adj.) 1516/43 mm Max. 25A6775 mm V2707 21/8760 mm 2/51 mm Hole in ceiling W/22 mm Max. (1/4"Ad).) 35716 mm Max. (½' Adj.) Y873 mm Mm. Typical ceiling 133/29 mm Mm. (3%' Adj.) 1%734 mm Mm. (½" Ad).) Finished surface 17/8 /47 mm Max. 25A&"/75 mm V3405 41.51 16372 Rev B Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 6 \4tauIic' 7 41.51 16372 Rev B Updated 07/2022 © 2022 Victaulic Company. All rights reserved, victaulic.com \4taulI jCe victaulic.com 5.0 PERFORMANCE Sprinkler is to be installed and designed as per NFPA, FM Datasheets, or any local standards. 6.0 NOTIFICATIONS A WARNING I m Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressur- ized and drained immediately prior to installation, removal, adjust- ment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Ratings: All glass bulbs are rated for temperatures from -670F/-550C. 1-40; Victaulic FirelockTM Automatic Sprinklers Installation and Maintenance Instructions 149: Style V9 VictaLilic rireLockiM IGSTM lnstallationReodyTM Sprinkler Coupling Installation Instructions User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendatinn for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. Victaulic® VicFIexTM Sprinkler Fittings 4tauiicr Series AH2 and AH2-CC Braided Flexible Hoses 10.85 SeriésAH2 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component Series AH2 1"/DN25 ID Braided Hose: 31, 36, 48, 60, 72/790, 915, 1220, 1525, 1830 mm. Note: length includes adapter nipple and 5.75/140 mm straight reducer. Series AH2-CC 1"/DN25 ID Braided Hose: 31, 36, 48, 60, 72/790, 915, 1220, 1525, 1830 mm. Note: length includes captured coupling and 5.75/140 mm straight reducer. Connections From Branchline 3%"/20mm BSPT female thread (VdS only) 1 '4732mm BSPT female thread (LPCB only) 1"/25mm NPT or BSPT female Thread 1725mm Grooved IGS (refer to Submittal 10.54 for additional IGS connections) No. 116 CPVC Adapter (1/25mm Female CPVC Socket x 1725mm Grooved IGS) No. 142 Welded Outlet Style 922 Outlet-T Style 920N Mechanical-T Outlet No. 65 Grooved End of Run Fitting Hose Inlet 1/25mm Grooved IGS 1"/25mm NPT or BSPT male thread 3/4"/20mm BSPT male thread (VdS only) 1 '/4/32mm BSPT male thread (LPCB only) ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph LSubmitted By Date Approved Date S victaulic.com 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. 1 ictaulic victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) Sprinkler Reducer Sprinkler Connection: ½' and 3/4"/15mm and 20mm NPT or BSPT female thread Straight Lengths: 5.75", 9", 13"/140mm, 230mm, 330mm 90° Elbows Standard Short Low Profile Short Standard Long Low Profile Long (Short elbows typically used with concealed sprinklers. Long elbows typically used with recessed pendent sprinklers) Brackets Style A132 for suspended and hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place Style A133 for surface mount applications, wood, metal and block walls, or ceilings Style A134 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment Style ABS for hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment Style A137 for suspended and hard lid ceilings Style A137 Adjustable for suspended and hard-lid ceilings Style AB10 for Armstrong® TechZoneTM ceilings Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 900 low profile elbows) Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 47100mm. Style ABBA bracket for suspended, exposed, and hard-lid ceilings Style ABMM bracket for surface mount and stand off-mount applications, wood, metal and block walls, or ceilings and hard-lid ceilings • Strut channel and pipe clamp, not supplied by Victaulic Maximum Working Temperature 2250F/107°C 150°F/650C (No. 116 CPVC Adapter) Maximum Working Pressure 200 psi/1375 kPa (FM Approval) 175 psi/1206 kPa (cULus Listed) 1600 kPa/232 psi (VdS/LPCB Approved) 1.4 MPa (CCCf Approved) 175 psi/1206 kPa (No. 116 CPVC Adapter) Minimum Bend Radius 7/178mm (FM/CCCf Approval) 2/51 mm (cULus Listed) 3776.2 mm (VdS/LPCB Approved) S S 10.85 5839 Rev AK Updated 03/2021 © 2021 Victauhc company. All rights reserved. victaulic.com 2 \Jt9UIiC victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) Maximum Allowable Sprinkler K-Factors FM (1/2715mm reducer) K5.6/8,1 (S.I.), (34"/20mm reducer) K14.0/20,2 (S.I.) cULus (1/2 /15mm reducer) K8.0/11,5 (S.I.), (3%I20mm reducer) K14.0/20,2 (S.I.) VdS/LPCB (½/15mm reducer) K5.6/8,1 (S.I.), (34/20mm reducer) K8.0/11,5 (S.I.) 2.0 CERTIFICATION/LISTINGS < c@ us RVdS 0-CB LISTED NOTE The VicFfex Series AH2 Hose has been tested and evaluated by Spears® for acceptable use with Spears® cvc Products and is therefore covered under the Spears® FlameGuard® Installer Protection Plan. 3.0 SPECIFICATIONS - MATERIAL Series AH2: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Nut and Nipple: Carbon Steel, Zinc-Plated Reducer (½"I15 mm or 3/4720 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated Series AH2-CC: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Coupling Retainer Ring: Polyethelene Nut: Carbon Steel, Zinc-Plated Reducer (1/2'715 mm Or 3/4'720 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: Orange enamel (North America, Asia Pacific). Red enamel (Europe). Hot dipped galvanized. Gasket:' Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type Ill Finish No. 116 Adapter Fitting: CPVC and Brass Seal: Victaulic EPDM 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 3 X A—c—ta—ulicr uirfiiIir mm 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose • I!1 ill I r_ —o ••1 H'i Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31 25.3 31 790 641 790 36 31.3 36 915 794 915 48 42.3 48 1219 1073 1220 60 54.3 60 1525 1378 1525 72 66.3 72 1830 1683 1830 Series AH2-CC Braided Hose Hose Length A B inches inches inches mm mm mm 31 24.5 29.8 790 622 757 36 29.5 34.8 915 749 884 48 41.5 46.8 1219 1054 1189 60 53.5 58.8 1525 1359 1494 72 65.5 70.8 1830 1 1664 1798 Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Adapter Nipple 6 Braid 7 Collar/Weld Fitting 8 Sleeve 9 Reducer Item Description Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut Captured Coupling 6 Braid 7 Collar/Weld Fitting 8 Sleeve 9 Reducer 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. uimfiiiIim mnm III 'JtauIac 350"! 3.63/ 2.84"! vo m 92 mm 48 4.0 DIMENSIONS (CONTINUED) Standard Reducer 5.75/140 mm straight reducer Optional Reducers 2.62! 66.5 mm 2.62"! 665 mm 7.257 1842 mm JEIlI 55°" 6.57"! 1 139.7 mm —7 m 5.00"! 9.0/229 mm straight reducer 43'7 3.25"! 127.0 mm 122. 7mm 82.6 mm II1IIlllllliIllllIll 11 .._...1. 13.0/330 mm straight reducer Short 900 elbow reducer Long 90° elbow reducer NOTE The Short 90° elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. FM/VdS Approved only. Low Profile 5.25"! 133 mm 116 mm i I 1.4"! 1.4"! 36mm 36mm k Short 90° elbow reducer Long 90° elbow reducer NOTE Style AB11: When low profiles elbows are with the Style AB11 bracket, the Low Profile Short Elbow is typically used with concealed sprinklers while the Low Profile Long Elbow is typically used in the installation of recessed pendent sprinklers. No. 116 CPVC Adapter EtoE NOTES E to E is 3.0"/76.0 mm The No. 116 CPVC Adapter has 2 ft. (0.6 ml EQI of 1" Schedule 40 pipe. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 5 \taUIic victaulic.com 4.1 DIMENSIONS Vicflex Brackets Suspended Ceilings Hard-Lid Ceilings LItem - Description L_1 24 /610mm0r48 /1219mm Square Bar 2 Patented Vertically Adjustable Center BracjJ 3 End Bracket NOTE Both sizes FM/VdS/LPCB Approved, cULus listed Style AB3 Surface Mount Applications FM/LPCB Approved Style AB4 Hard-Lid Ceilings with Hat furring channel grid system Item Description 1 24/610mm or 48/1219mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket for Hat Furring Channel NOTE Both sizes FM/VdS/LPCB Approved, cULus listed. 10.85 5839 Rev AK updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com \4taulacr Style A137 Adjustable Suspended Ceilings Hard-Lid Ceilings Item Description 1 700mm or 1400 mm Square Bar , 2 Patented 1 -Bee26 Center Bracket 3 End Bracket (adjustable) NOTE Both sizes FM/VdS/LPCB Approved. ,uf2I.lir 4.2 DIMENSIONS Vic flex Brackets Style AB5 Hard-Lid Ceilings Item Description 1 24/610mm or 48"/1219 mm Square Bar 2 Patented Vertically Adjustable center Bracket 3 End Bracket NOTE Both sizes FM/VdS/LPCB Approved, cULus listed. Style AB7 Suspended Ceilings Hard-Lid Ceilings Item Description 1 247610 rhm or 48/1219mm Square Bar 2 Patented 1Bee2x Center Bracket 3 End Bracket NOTE Both sizes FM/VdS/LPCB Approved. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. ujt-+i ii it. rnm FA \1taL1Iicr Style AB11 Suspended ceilings Hard-Lid ceilings Item Description 1 24°/610mm or 48/1219mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE FM/VdS Approved, cULus listed. 4.3 DIMENSIONS VicFiex Brackets Style AB1O Suspended ceilings Armstrong TechZoneTM Item Description 1 6"/152 mm Square Bar 2 Patented I -Bee2l Center Bracket 3 End Bracket NOTE FM/VdS/LPCB Approved, cULus listed. Style AB12 Suspended ceilings Hard-Lid ceilings Item Description 1 Style A131 2 Bracket Body 2 #2 Square Drive Set Screw NOTE FM/VdS Approved. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 8 \JtaUIic Style ABMM Surface mount Stand-off mount L Item Description Style ABMM Bracket Body 2 Cap Screw, Serated Flange, M6 x 1 x 15.24, T25 Torx Drive Recessed 14142l ,Iu' rrm 4.3 DIMENSIONS (CONTINUED) VicFlex Brackets Style ABBA Floor-above mount Cantilever mount Temporary mount in exposed ceilings Item Description 1 Style ABBA Mounting Plate 2 Style ABBA Square Bar Cap Screw, Serated Flange, M6 x 1 x 20, T25 Torx Drive Recessed 4 Style ABMM Bracket Body Cap Screw, Serated Flange, M6 x 1 x 15.24, T25 Torx Drive Recessed NOTE FM Approved. NOTE FM Approved. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. Ifid-f M1 114- f-nm ,NJ tauIic victaulic.com 4.4 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket Bracket Assembly Style AB2 4 ' 37 . 111mm 1/8715.9 mm I I - Typical ceiling tile I Finished surface 247610 mm or 48/1219mm on Center V2707 3/4"/19 MM MAX. RECESS 23/8'/60.33 mm 1.7'/43 mm Typical ceiling grid See note J- V2707 MAX. EXTENSION Hose Clearance Chart Straight Reducer Long Elbow Short Elbow V2707 V3802 V2707 V3802 3/4 1 1/2" 3/4" ½' V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess 3/4" Max Recess ½" Max Recess 3/4" Max Recess ½ Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm AR" Minimum 2.0 3.0 7.0 - Bend Radius 50 80 175 "A Minimum Required 8.6 10.1 9.6 11.1 13.6 15.1 5.8 5.8 Installation 218 269 244 281 345 383 147 147 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com ) 10 \t9UIiC" 2616768 mm max. hole 4.5 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket See chart 2"x4" Stud If 1 Bracket Assembly Style AB2 Typical 167406 mm C/C A See Chart 1.8745 mm II . . 3½'! 89 mm Finished /8716 mm c Typical ceiling I drywall V381/2'71 3 m MAX. RECESS V38 MAX. EXTENSION Hose Clearance Chart Straight Reducer V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 /4'11 20mm WI 13mm 3/4' 120mm 3/4" 120mm ½" 113mm /4"l 20mm /4'l 20mm ½' I 13mm /4"l 20mm Max Recess' Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm ( mm mm "R" Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A" Minimum Required 6.2 7.6 6.1 7.2 8.6 7.1 11.2 12.6 11.1 Installation 158 193 155 183 218 180 285 320 282 Space Hose Clearance Chart Long Elbow Short Elbow V2707 V2709 V3802 3W I 20mm 3/4' 120mm ½' I 13mm Max Recess Sidewall Max Recess inches inches inches mm mm mm 'R' Minimum Bend Radius - "A" Minimum Required 3.3 3.6 3.3 Installation 84 91 84 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 11 \j4t9UIiC" Bracket assembly Style AB4 #10 Screw 111 - Typical 16/406 mm C/C -.-- V27 3/4'/19 mm MAX. RECESS .1:... 4.6 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB4 Bracket See chart A See Chart 4.1/ 21/8760 mm 104 mm max. hole 2/51 mm mm. hole _i_• v,.IIII --_ _uIOI -u._ ceiling 1/8"/ m al V27 MAX. EXTENSION Hose Clearance Chart Straight Reducer LongElbow ShortElbow V2707 V3802 V2707 V3802 3/4" 1/2" 3/4" 1/2" V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess 3/4" Max Recess ½" Max Recess 3/4" Max Recess ½" Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm I mm "R" Minimum 2.0 2.0 3.0 3.0 7.0 7.0 BendRadius 50 50 80 80 175 175 - "A" Minimum Required 8.8 10.2 9.8 11.2 13.8 15.2 8.0 5.9 Installation 224 259 249 285 351 386 203 150 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victautic Company. All rights reserved. victaulic.com 12 /tiuIic." 2W/60 mm max. hole V27 MAX. EXTENSION victaulic.com 47 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB5 Bracket N R See chart A See chart Bracket asse bly 2.37 I 57mm Style 2' x 4' 35,t/ metaistud i fl. iI fl' 92mm on Finished /a'/16 mm ceiling Typ. Drywall —Typical 167406 mm C/C - V271/4'7119 mm MAX. RECESS Hose Clearance Chart Straight Reducer °V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 /4l 20mm WI 13mm WI 20mm /4"l 20mm WI 13mm WI 20mm WI 20mm WI 13mm 3/4' 120mm Max Recess" Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm R" Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A" Minimum Required 6.0 7.7 6.1 7.0 8.7 7.1 11.0 12.7 11.1 Installation 158 196 155 178 221 180 279 323 282 Space Hose Clearance Chart Low-Profile Long Elbow Long Elbow Short Elbow V2707 V3802 V2709 V3802 V3802 /4'I 20mm WI 13mm 3/4"1 20m ½" I 13mm WI 13 mm Max Recess Max Recess Sidewall Max Recess Max Recess inches inches inches inches inches mm mm mm mm mm "R" Minimum I Bend Radius "A" Minimum Required 3.5 4.9 3.6 2.9 3.3 Installation 89 124 91 74 84 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 13 \JLim auuiice victaulic.com 4.8 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) 2/s76O mm 211A6768 mm I '- Bracket 2/51 mm 21/8760 mm çp StyleABli mm. hole mm. hole See Cha rah rt LH.:::3.07 76 mm J Assembly JllhtIjIJ max. hole max. hole 1.7/43 mm Finished cal 1/8"/ 15.9 mm ceiling ceiling grid Typical SeeNote 247610mm0r gfac ceiling tile V27 V38 4871219 mm on center Pendent Hose Clearance Chart Low-Profile Low-Profile Long Elbow Short Elbow V2707 V3802 3/4!'120mm ½'113mm Max Recess Max Recess inches inches mm mm 'A' Minimum Required 4.0 3.9 Installation 102 99 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 14 'j(ctauIic I Ce of TypCeI Ce3irg V2707 36/12.7 m MAX. RECESS Pypical ceiiirig V2707 W719 mm MAX. RECESS Noroinol 6 14/3556 victaulic.com 4.9 DIMENSIONS Clearances Style AB12 and ABBA Bracket Suspended Ceiling Grid with Recessed Sprinkler with Low Profile Short Elbow Suspended Ceiling Grid with Recessed Sprinkler and Straight 5.757140 mm Reducer Low Profile Low Profile Standard Standard Standard Dimension Short Elbow Long Elbow Short Elbow Long Elbow Straight Reducer 3/4719 1111M 3/4719 MM 3/4719 MM 3/4119 MM 3/4719 MM Recessed* concealed Recessed Concealed Recessed Concealed Recessed Concealed Recessed Concealed inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm I mm mm A Minimum Required 4.0 5.5 5.6 7.2 5.9 7.5 7.7 9.3 15.0 16.6 Installation Space 101.6 139.7 142.2 182.9 149.9 190.5 195.6 236.2 381.0 421.6 Distance from Top of B Typical Ceiling Tile to 05 20 15 15 15 15 30 30 30 30 12.7 Bottom of Gate 50.8 38.1 38.1 38.1 38.1 76.2 76.2 76.2 76.2 * Adjustability will be limited Style ABMM Bracket Stand-off Dimensions 3/ 2.9t'/ 100 mm II .1 75 mrY /LL / 56 mm 10 mm 7 m 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic company. All rights reserved. victaulic.com 15 -1 ~, Ac _ta _U, ii C r victaulic.com 4.10 DIMENSIONS Clearances Style AB3 and ABMM Bracket Surface Mount Application with Recessed Sprinkler 2/51 mm mm. hole Hose Clearances inches inches inches inches inches inches inches inches inches inches Dimension mm mm mm mm mm mm mm mm mm mm WallThickness 2 4 6 8 10 2 4 6 8 10 "A 50 100 150 200 250 50 100 150 200 250 Outlet Length 5.75 9 13 5.75 9 13 9 13 13 13 5.75 9 1 13 5.75 1 9 13 9 13 13 13 B" 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 HoseClearance 11.6 14.8 18.8 9.6 12.8 16.8 10.8 14.8 12.8 10.8 12.6 15.8 1 19.8 10.6 1 13.8 17.8 11.8 15.8 13.8 11.8 "C" 294 376 478 243 325 427 275 376 325 275 319 402 503 268 1351 452 300 402 351 300 Bend Radius 7 8 "R" 175 200 NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 16 Licctaullicr victaulic.com 4.11 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with Style 922 threaded outlet Series AH2-CC Braided Hose with Style 922 grooved outlet art art Hose Clearance Chart Dimension inches inches inches inches inches mm mm mm mm mm R Minimum 3 4 5 6 7 Bend Radius 80 100 125 150 175 A Mm. 9.4 10.4 11.4 12.4 13.4 238 263 289 314 339 Hose Clearance Chart Dimension inches inches inches inches inches mm mm mm n1m mm R Minimum 3 4 5 6 7 Bend Radius 80 100 125 150 175 A Mm. 7.7 8.7 9.7 10.7 11.7 197 222 247 273 298 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 17 ictaulicr :i,4uli, 4.12 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with female threaded outlet Series AH2-CC Braided Hose with grooved outlet iii Hose Clearance Chart Dimension inches inches inches inches inches mm mm mm mm mm R Minimum 3 4 5 6 7 Bend Radius 80 100 125 150 175 A Mm. 9.4 10.4 11.4 12.4 13.41 239 264 290 315 341 Hose Clearance Chart Dimension inches inches inches inches inches mm mm mm mm mm R Minimum 3 4 5 6 7 Bend Radius 80 100 125 150 175 A Min. 8.1 9.1 10.1 11.1 12.1 205 231 256 281 307 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. viCtauIiC.Com R 4tauiicr victaulic.com 5.0 PERFORMANCE - FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses with Straight 5.757140 mm Reducers USTED Style AB2, AB4, AB5 and AB1O Brackets Hose Reducer UL_____________________ Equivalent Length of Length Nominal Outlet Size 1/33.7mm Sch. 40 pipe inches inches feet mm Type DN meters Max Bends 31 Straight ½ 15.0 790 DN15 4.6 31 Straight ½ 16.0 790 DN15 4.9 31 Straight 3/4 19.0 790 DN20 5.8 31 Straight 34 20.0 790 DN20 6.1 36 Straight ½ 18.0 915 DN15 5.5 36 Straight ½ 21.0 915 DN15 6.4 36 Straight 3/4 21.0 915 DN20 6.4 36 Straight 3/4 230 915 DN20 7.0 48 Straight ½ 21.0 1220 DN15 6.4 48 Straight ½ 32.0 -. 8 1220 brns 9.8 48 Straight 3/4 26.0 1220 DN20 7.9 48 Straight 3/4 37.0 8 1220 DN20 11.3 60 Straight ½ 27.0 1525 - DN15 8.2 60 Straight ½ 46.0 10 1525 DN15 14.0 60 Straight ~ 27.0 1525 DN20 8.2 60 Straight ~ 46.0 10 1525 DN20 14.0 72 Straight ½ 31.0 1830 DN15 9.4 72 Straight ½ 55.0 12 1830 DN15 16.8 72 Straight 3/4 30.0 1830 DN20 9.1 72 Straight 3/4 60.0 12 1830 DN20 18.3 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 19 \,Ltaulic° victaulic.com 5.0 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) ceus Series AH2 and AH2-CC Braided Hose with 900 Low Profile Elbows LISTED Style AB11 VicFIex Bracket Hose Reducer, UL Equivalent Length of Length Nominal Outlet Size 1/33.7mm Sch. 40 pipe inches inches feet mm Type ON meters Max Bends 31 LP Elbow ½ 18.0 790 DN15 5.5 31 LP Elbow ½ 24.0 790 DN15 7.3 31 LP Elbow 3/4 21.0 790 DN20 6.4 31 LP Elbow 3/4 24.0 790 DN20 7.3 36 LIP Elbow ½ 19.0 915 DN15 5.8 36 LP Elbow ½ 26.0 915 DN15 7.9 36 LP Elbow 3/4 23.0 915 DN20 7.0 36 LP Elbow 3/4 28.0 915 DM20 8.5 48 LP Elbow ½ 23.0 1220 - DN15 7.0 48 LP Elbow ½ 43.0 8 1220 DN15 13.1 48 ' LP Elbow 3/4 30.0 1220 DN20 9.1 48 LP Elbow ~ 42.0 8 1220 DM20 12.8 60 LP Elbow ½ ' 28.0 1525 DN15 8.5 60 LP Elbow ½ 49.0 10 1525 DN15 14.9 60 LP Elbow ~ 31.0 1525 DN20 9.4 60 LP Elbow 3/4 50.0 10 1525 DN20 15.2 72 LP Elbow ½ 31.0 1830 DN15 9.4 72 LP Elbow ½ 65.0 12 1830 DN15 19.8 72 LP Elbow ~ 36.0 1830 DN20 11.0 72 LP Elbow 1/4 63.0 12 1830 DM20 19.2 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com Ell J'tauIic' victaulic.com 5.0 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2/51 mm center line bend radius Nominal Outlet 1 2 3 4 5 6 7 8 9 10 11 12 Length Size Bend Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends inches inches feet feet feet feet feet feet feet feet feet feet feet feet mm DN meters meters meters meters meters meters meters meters meters meters meters meters 31 1/2 11.0 13.0 15.0 16.0 790 DN15 3.4 4.0 4.6 4.9 - - - - - - 31 3/4 12.0 14.0 19.0 20.0 790 DN20 3.7 4.3 5.8 6.1 - - - - - - - 36 1/2 14.0 16.0 18.0 19.0 21.0 1915 DN15 43 4.9 5.5 5.8 6.4 - - - 36 3/4 17.0 19.0 21.0 22.0 23.0 915 DN20 5.2 5.8 6.4 6.7 7.0 - - - - - - - 48 1/2 18.0 19.0 21.0 23.0 25.0 27.0 30.0 32.0 1220 DN15 5.5 5.8 6.4 7.0 7.6 8.2 9.1 9.8 - - - - 48 3/4 21.0 24.0 26.0 28.0 31.0 33.0 35.0 37.0 1220 DN20 6.4 7.3 7.9 8.5 9.4 10.1 10.7 11.3 - - - - 60 1/2 21.0 24.0 27.0 30.0 32.0 35.0 37.0 40.0 43.0 46.0 1525 DN15 6.4 7.3 8.2 9.1 9.8 10.7 11.3 12.2 13.1 14.0 - 60 3/4 23.0 25.0 27.0 29.0 32.0 34.0 37.0 40.0 43.0 46.0 1525 DN20 7.0 7.6 8.2 8.8 9.8 10.4 11.3 12.2 13.1 14.0 - - 72 1/2 27.0 29.0 31.6 34.0 37.0 40.0 43.0 46.0 48.0 50.0 52.0 55.0 1830 DN15 8.2 8.8 9.4 10.4 11.3 12.2 13.1 14.0 14.6 15.2 15.8 16.8 72 3/4 260 280 3.0.0 330 370 400 440 480 510 540 570 600 1830 DN20 7.9 8.5 9.1 10.1 -- 11.3 12.2 13.4 14.6 15.5 16.5 17.4 18.3 NOTES: Values for use with 5.757140 mm straight reducers. The values in this table are provided by the manufacturer for reference only. For friction loss data in accordance with the UL Certification, please refer to pages 19 and 20 of this publication. How to use this Design Guide: For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 21 LicctaulliiI3r victatilic.com 5.1 PERFORMANCE - FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, AB7 Adj., A138, AB1O, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 900 Bends Stainless Steel Outlet 1733.7 mm at 7/178mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 1/2 13.8 15 4.2 31 5.6 Straight 790 8.1 2 ½ 15 23 90 Elbow 71 1/2 16.6 15 5.1 36 5.6 Straight 915 8.1 2 ½ 15 25.6 90' Elbow 7.8 ½ 15 48 5.6 Straight 7.1 1220 8.1 ½ 15 30.7 90 Elbow 9.3 1/2 30.2 15 9.2 60 5.6 Straight 1525 8.1 ½ 15 35.9 90 Elbow 10.9 ½ 15 37.0 72 5.6 Straight 11.3 1830 8.1 ½ 15 41.1 90' Elbow 12.5 3/4 20 16.8 31 8.0 Straight 5.1 790 11.5 2 ~ 20 16.8 90' Elbow 5.1 3/4 20 20 36 8.0 Straight 6.0 915 11.5 2 3/4 20 19,7 90' Elbow 6.0 3/4 27.8 20 8.4 48 8.0 Straight 1220 11.5 ~ 20 26.6 90' Elbow I 8.1 FM NOTES: The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preactior, systems per NFPA 13, 13R, and 130 and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. EXAMPLE; A 48-inch hose installed with two 300 bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victauliccom 22 Licctaullicr victaulic.com 5.1 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) FM Series AH2 and AH2-CC Braided Hoses Style AB2, A133, AB4, AB5, AB7, AB7 Adj., A138, AB10, AB12, ABBA and ABMM VicF!ex Brackets Maximum Equivalent Number Length of Length of of 90° Bends Stainless Steel Outlet 1/33.7mm at 7/178mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 3/4 35.7 20 60 8.0 Straight 10.9 1525 11.5 3,4 0 33.6 90 Elbow 10.2 3/4 43.5 20 72 8.0 Straight 13.2 1830 11.5 3/4 20 40.6 90 Elbow 12.2 3/4 16.5 20 5 .0 31 11.2 Straight 790 16.1 2 3/4 20 17.8 90 Elbow 5.4 3/4 19.5 20 36 11.2 Straight 915 16.1 2 3/4 20 20.7 90 Elbow 6.3 26.7 20 8.1 48 11.2 Straight 1220 16.1 3/4 20 27.9 I 90 Elbow 8.5 3/4 20 33.9 60 11.2 Straight 10.3 1525 16.1 3/4 20 35 90 Elbow 10.7 3/4 20 41.3 72 11.2 Straight 12.5 1830 16.1 3/4 20 422 90 Elbow 12.8 3/4 14.9 2 31 14.0 Straight 4.5 790 20.2 3/4 2 0 15.5 90 Elbow I 4.72 FM NOTES: The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 23 \,,htaulicr victaulic.com 5.1 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) FM Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, A135, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 90 Bends Stainless Steel Outlet 1733.7 mm at 77178mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. I type meters 3/4 19.4 20 36 14.0 Straight 915 20.2 2 20 3/4 196 90 Elbow 59 20 48 14.0 Straight . 1220 20.2 3 ~ 20 29.5 90 Elbow 8.9 3/4 20 33.9 60 14.0 Straight 10.3 1525 20.2 3/4 20 341 90 Elbow 10:4 3/4 7.5 72 14.0 Straight 1.4 1830 20.2 3/4 20 386 90 Elbow 11.7 FM NOTES: The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. EXAMPLE: A 48-inch hose installed with two 30° bends and two 900 bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 2400, which is less than the allowable 2,70°. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 01 Licctaulliilor victaulic.com 5.2 PERFORMANCE - FRICTION LOSS DATA Series AH2 Braided Hose with 900 Low Profile Elbows Style AB5, AB11, AB12, ABBA and ABMM VicFlex Bracket Maximum Equivalent Number Length of Length of of 900 Bends Stainless Steel Outlet 1733.7mm at 77178mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches Imperial inches feet mm S.I. mm meters 31 5.6 ½ 13.7 790 8.1 15 4.2 2 36 5.6 ½ 17.0 915 8.1 15 5.2 2 48 5.6 ½ 25.0 1220 8.1 15 7.6 3 60 5.6 ½ 33.0 1525 8.1 15 10.1 4 72 5.6 ½ 41.1 1830 8.1 15 12.5 4 31 8.0 3/4 13.6 790 11.5 20 4.14 2 36 8.0 3/4 16.9 915 11.5 20 5.2 2 48 8.0 3/4 27.8 1220 11.5 20 8.5 3 60 80 ~ 326 1525 11.5 20 9.9 4 72 8.0 3/4 40.6 1830 11.5 20 12.4 4 31 11.2 3/4 13.7 790 16.1 20 4.2 2 36 11.2 3/4 17.0 915 16.1 20 5.2 2 48 11.2 3/4 24.9 1220 16.1 20 7.6 3 60 11.2 3/4 32.9 1525 16.1 20 10.0 4 72 11.2 3/4 40.9 1830 16.1 20 12.5 4 31 14.0 3/4 13.5 790 20.2 20 4.1 2 36 14.0 -3/4 16.8 915 20.2 20 5.1 2 48 14.0 3/4 24.7 1220 20.2 20 7.5 60 14.0 3/4 32.7 1525 20.2 20 9.9 4 72 14.0 3/4 40.7 1830 20.2 20 12.4 FM NOTES: The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. virfIllif- r°nm 25 'NJLiectsullicr victaulic .com 5.3 PERFORMANCE - FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hose Vd S] Style AB2, AB4, AB5, AB7, A137 Adj., AB8, A1310, AB11 and AB12 Brackets Equivalent Length of Length of steel pipe according to Stainless Steel Outlet EN 10255 ON 25 Maximum Number Flexible Hose Size (33,7 x 3,25) of 90" Bends at mm DN meters 3776.2mm Bend inches inches feet Radius DN 15 790 1/2 5.5 31 18.0 0N20 3/4 DN1 5 915 ½ 6.4 36 21.0 3 DN20 3/4 DN1 5 1220 ½ 8.5 48 27.9 3 DN20 3/4 DN1S 1525 ½ 10.7 60 35.1 4 DN20 3/4 DN1S 1830 ½ 12.8 72 42.0 4 DN20 3/4 VdS Ceiling Manufacturers List AB2, AB7, AB10 ,AB11 AB4 AB5, AB8 1.AMF Armstrong Chicago Metallic Dipling Durlum Geipel Gema-Armstrong Hilti 9.Knauf Lafarge Linder Odenwald Richter Rigips Rockfon Pagos Suckow & Fischer USG Donn No specific approval Hilti Knauf Lafarge Lindner Rigips 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 26 jtauIicr victaulic.com 5.3 PERFORMANCE - FRICTION LOSS DATA OLPCB Series AH2 and AH2-CC Braided Hose Style AB2, AB3, AB4, AB5, AB7, AB8, and AB10 Brackets Length of Equivalent Length Maximum Stainless of steel pipe Number of Steel according to 90" Bends at Flexible Outlet EN 10255 DN 25 3776.2mm Hose Size (33,7 x 3,25) Bend Radius mm mm inches meters inches type feet 15 mm ½ 790 Straight 1.8 31 6.0 2 20mm 3/4 Straight 15 mm ½ 915 Straight 3.6 36 11.9 20mm 3/4 Straight 15 mm ½ 1220 Straight 4.3 48 14.0 3 20mm 3/4 Straight 15 mm ½ 1525 Straight 4.1 60 13.6 20mm 3/4 Straight 15 mm ½ 1830 Straight 5.5 72 18.1 3 20mm 3/4 Straight Series AH2 Braided Hose ,- Style AB2, AB3, AB4, AB5, AB7, AB8, AB10 and AB12 Brackets Equivalent Length of Length of 1'733.7 mm Sch. 40 Pipe Flexible Hose Straight Configuration Bend Configuration mm meters meters inches feet feet 790 0.87 2.70 31 2.9 8.9 915 1.00 2.80 36 3.3 9.2 -1220 2.23 4.66 48 7.3 1525 2.90 6.5 60 9.5 21.3 1830 3.31 7.16 72 10.9 23.5 CCCF NOTE Friction loss data is in accordance with G135135.16 tested at a flow rate of 114 liters per minute (30 gallons per minute). 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. uirfpilit mm 27 'Jt9UIIC victauIic.om 6.0 NOTIFICATIONS WARNING I "'Aw P"! Ou L 46 Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depres- surized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain im- portant information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. WARNING It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. It is the responsibility of the owner of a building or their authorized agent to provide the sprinkler system installer with any knowledge that the water supply might be contaminated with or conducive to the development of micro- biologically influenced corrosion (MIC), including as required by NFPA 13. Failure to identify adverse water quality issues may affect the VicFlex product and void the manufacturer's warranty. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. /7 Victaulic VicFlex Series AH2 and AH2-CC Flexible Sprinkler Fittings may be painted provided the paint is compatible with stainless steel and zinc-plated carbon steel or ductile iron. Care should be taken to ensure the sprinkler and associated escutcheon or coverplate are not painted. Victaulic VicFlex Series AH2 and AH2-CC penetrating through non-fire rated gypsum wall (drywall) will function as designed, provided the components are installed in accordance with the respective installation instructions referenced in this document. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 28 \JftaUIiC iirfiiIir rm 7.0 REFERENCE MATERIALS - CHARACTERISTICS VicFlex Maximum Load Values Series AH2 Hose with 24" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m lb N Ib/Iinearft N/Iinearm 31/790 0.8 _7 5.2 23 2.6 38 36/915 0.9 5.5 25 2.8 40 48/1220 6.3 28 3.1 46 1.2 60/1525 15 7.0 31 3.5 51 72/1830 168 Series AH2 Hose with 48" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m lb N lb/linearft N/linearm 31/790 2.6 6.1 27 1.5 22 0.8 36/915 0.9 6.4 29 - 1.6 23 48/1220 1.2 7.2 32 1.8 26 60/1525 7.9 35 2.0 29 1.5 72/1830 168 8.7 39 2.2 32 Total Load is defined as the sum of the weights of the following: water-filled flexible sprinkler hose with threaded end fittings, including a typical fire sprinkler bracket assembly (any applicable Victaulic bracket model of the relevant associated size) ASTM C 635: Suspension System Load-Carrying Capabilities (excerpted) Suspension System Actual Length ft/rn Mm. Allowable Uniform Load lb/linear ft N/linear m Direct Hung Light 5.0 75.7 Intermediate 12.0 181.0 Heavy 16.0 241.7 SUMMARY: All direct-hung suspension system duty classifications per ASTM C 635 are able to withstand the maximum water-filled weight of the VicF/ex sprinkler hose and bracket. 10.85 5839 Rev AK updated 03/2021 © 2021 Victaulic Company. All rights reserved. ikfiiIir mm 29 JtauI iC victaulic.com 7.0 REFERENCE MATERIALS - CHARACTERISTICS (CONTINUED) Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends 2X Minimum Minimum Minimum bend radius bend radius bend radius \ OR Minimum OR I bend radius dius Minimum bend radius Minimum Minimum bend radius - b radius Minimum \< NOTE For out-of-place (three-dimensional) bend, care must be taken to avoid imparting torque on the hose. I-VicFlex-ABI-AB2 I-Vie Flex-AB3 l-VicFlox-AB4 l-VicFlex-AB5 I-VicFlex-AB7 I-VicFlex-A!312 I-Vie Flex-AR BA I- Vic Fl ex-A B M M 1-RES User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products fora particular end-use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations. instructions. Nothing in this or any other document, nor any verbal recommendation, Installation advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to l-VICF1_EX-AB1-AB2-AB10, l-VICFLEX-AB4, or waive any provision of Victaulic Company's standard conditions of sale, installation I-VICFLEX-AB7, or I-VICFLEX-A88 for the product you are installing. Handbooks are guide, or this disclaimer, included with each shipment of Victaulic products for complete installation and assembly Intellectual Property Rights data, and are available in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or Contact Victaulic for details. under any patentor other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such Trademarks material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms "Patented" or "Patent Pending" refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company, All rights reserved. victaulic.com 30 \,s4tauIicr Bull Moose Fire Sprinkler Pipe Produci 0.0. (in) 1.315 1 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 (in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 6.351 8.249 Empty Weight )lb/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 Water Filled Weight (lb/ft) 1.820 2.518 3.053 4.223 5.893 1.957 11.796 23.038 40.086 V 0. - C.R.R.[ 15.21 9.91 1.16 6.21 4.92 3.54 2.50 1.158 1.805 ' Pieces per Lift 91 61 61 31 30 19 19 10 1 Lift Weight (Ibs) 21 lengths 2,695 2,319 2,511 2,051 2,224 1,732 2,242 1,951 2,490 Lift Weight (Ibs) 24 lengths 3.019 2.650 3,060 2,344 2,542 1.919 2,563 2,230 2,848 Lift Weight (Ibs) 25 lengths 3,208 2,760 38181 2,442 2,648 2,062 2,670 Information 1.315 1.560 1.900 1 2.375 2.875 1 3.500 14.500 - 1.049 1.380 1.610 2.067 2.469 3.068 4.026 1.680 2.210 2.120 3.650 5.800 7.580 10.800 2.055 2.918 3.602 5.114 7.815 10.783 16.315 - 1.00 1.00 1.00 1.00 1.00 1.00 1.00 10 51 44 30 30 19 19 2,410 2,431 2,513 2,306 3,654 3,024 4,309 2,822 2,778 2,872 2,635 4,116 3,456 4,925 2,940 2,894 2,992 2,745 4,350 3,601 1 5,130 : i 11111 i i ii! i 4 As the leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength—plus reliable service You need Bull Moose SCHEDULE 10 6 40 ADVANTAGES: Th UL listed (US & Canada) and FM approved ASTM A135 and A795 Type E, Grade A Certified Complies with NFPA-13, 13R and 14 Industry-leading hydraulic characteristics CRR of 1.0 and greater All pipe NDT weld tested c®us LISTED APPROVED r BENEFITS/SERVICES.- - • We have the most stocking locations in the industry, for best delivery and availability Plain end or roll groove Eddy Guard II" bacterial-resistant internal coating Custom length options Hot dipped galvanization Reddi-Pipe® red or black pipe eliminates field painting Compatible for use in wet, dry, preaction and deluge sprinkler systems The only maker with EPDs (to help earn LEED points). (] A ONFSA NFFW — FM Approved and Fully Listed Sprinkler Pipe Wheatland Tube's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL® and C-UL Listed. Wheatland Tube is the only manufacturer with FM Approval on 10 NPS Schedule 10 steel fire sprinkler pipe. Approvals and Specifications Schedule 10 and Schedule 40 meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10,1-10 NPS) ASTM A795, Type E, Grade A (Schedule 40,11-2 NPS) ASTM A53, Type E, Grade B (Schedule 40, 2-8 NPS) ASTM A53, Type F, Grade A (Schedule 40,11-4 NPS) NFPA® 13 and NFPA 14 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings Schedule 10 and Schedule 40 can be ordered in black or hot-dip galvanized to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A53 or A795. Schedule 10 and Schedule 40 receive a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted without special preparation. Every black steel Schedule 10 and Schedule 40 pipe also receives our MIC SHIELD TM antimicrobial coating to limit corrosion from microbes on the interior of the pipe. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Bar coding is acceptable as a supplementary identification method. PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: LI BLACK LI HOT-DIP GALVANIZED 1 Council Avenue, P.O. Box 608 Wheatland, PA 16161 P 800.257.8182 F 724.346.7260 info@wheatland.com wheatland.com Follow us on Twitter: WheatlandTube Wheatland Tube A DIVISION OFZEKELP4AN INDUSTRIES SCHEDULE 10 WEIGHTS AND DIMENSIONS WT./FT. WT./LIFT WT./LIFT WT./LIFT NPS NOMINAL OD NOMINAL ID NOMINAL WALL WT./FT. H.0 FILLEDPCS./LIFT 21 24 25 UL r-j in. if mm in. mm II mm 1 lbs.[ lbs. lb.. j. Ibs.t[ lbs. CRR 1 1.315 33.4 1.097 27.9 0.109 2.77 1.405 1.814 70 2065 2360 2459 11.4 1% 1.660 42.2 1.442 36.6 0109 2.77 1.807 2.514 61 2315 2645 2756 73 .L . , 1% 1.900 48.3 1.682 42.7 0.109 2.77 2.087 3.049 61 2673 3055 3183 5.8 'Y 1'. .•ç 2 2.375 60.32.157 54.8 0.109 2.77 2.640 J 4.222 37 - 2051 2344 2442 4.7 2% 2.875 73.0 2.635 66.9 0.120 3.05 3.354 5.895 30 2226 2544 2651 3.5 --r - 'r F. - . I 1t '' ............ 3 3.500 88.9 3.260 . 82.8 0.120 3.05 .: 4.336 7.949 1 19 1730 1977 2060 2.6 .- - /'.. . ,: , -. .- ., ..............-.-..-.-.-..- ... - .1 4 4.500 114.3 4.260 108.2 0.120 3.05 5.619 11.789 19 2242 2562 2669 1.6 1 5 5.563 141.3 5.295 134.5 0.134 3.40 7.780 17.309 13 2124 2427 2529 1.5 6 6.625 ..., , 168.3 ' 6.357.L 161:5 .0.134 3.40 9.298 23.038 ',' 10 .1953 2232 2325 1.0 8 8.625 2191 8 249 I 209 5 .... 0.188 4.78 16.960 .'.___.-..-_r-_ 40086 .... 7 2493 2849 2968 1.7 -- - - Ii ---------- S... 10" 10.750 273.0 10.374 263.5 0.188 4.78 21.230 57.803 2 892 1019 1062 - SCHEDULE 40 WEIGHTS AND DIMENSIONS WT./FT. WT./LIFT WT./LIFT WT./LIFT NPS NOMINAL OD NOMINAL ID NOMINAL WALL WT./FT. HOFILLED PCS./LIFT 21 24 25' UL In mm .1 _j mm mm in ][ mm7 Ib ,j lbs 1 f lbs 1 lbs [ lbs 1 1.315 33.4 1.049 26.6 0.133 3,38 - 1.68 2.055 , 70 , 2470 2822 2940 1.000 11/4 1.660 42.2 1.380 351 ----------------------------------------------._ 0.140 3 56 2 27 2 922 51 2431 2778 2894 1.000 1% 1.900 48.3 1.610 1.610 40.9 40.9 0.145 3.68 2.72 3.602 44 2513 2872 2992 1.000 '---p - - ... -10 --II'- 2 2.375 603 2.067 52.5 0.154 3.91 366 . 59 24 L 1845 2108 2196 1.000 21/2 2.875 73.0 2.469 62.7 0.203 5.16 5.80 7.871 20 2436 2784 2900 1.000 3 3.500 88.9 3.068 0.216 5.49 758 10 783 jL 13 2069 2365 2464 1.000 31/2 4.000 101.6 3.548 90.1 0.226 5.74 9.12 13.400 10 1915 2189 2280 1.000 4 4.500 114.3 i 4.026 102.3 0.237 6.02 10.80 16.311 10 1, 2268 2592 2700 1-000 5 5.563 , 141.3 5.047 - 158.2 0.258 6.55 14.63 , - 23.262 - 7 2151 2458 2560 , 1.000 6 6.625 168.3 6.065 4, 1541 0.280 711 18.99 31.498 5 L 1994 2279 1 2374 1.000 8" 8.625 219.1 7.981 202.7 0.322 8.18 28.58 50.240 5 3001 3430 3573 1.000 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). 8 NPS Schedule 40 and 10 NPS Schedule 10 are FM Approved but not UL Listed. & C@ APPROVED WFS-072921 1 Council Avenue, P.O. Box 608 info@wheatland.com Wheatland, PA 16161 wheatland.com P 800.257.8182 Follow us on Twitter: F 724.346.7260 . iThWheatlandlube fWheatland Tube A 0/VISION OFZEKELP4AN INDUSTRIES Victaulic® FireLockTM Fittings A—c—ta—ulicr 10.03 1.0 PRODUCT DESCRIPTION Available Sizes 1 1/4 - 8/DN32 - DN200 Maximum Working Pressure Pressure ratings for Victaulic FireLockTM Fittings conform to the ratings of Victaulic FireLock EZTM Style 009N couplings (refer to publication 10.64 for more information). Application FireLockTM fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Connects pipe, provides change in direction and adapts sizes or components Pipe Materials Carbon steel 2.0 CERTIFICATION/LISTINGS C®US <S> ILPCBJ USTED (E : EN 10311 Regulation (EU) No. 305/2011 3.0 SPECIFICATIONS - MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12. Fitting Coating: O Orange enamel. O Red enamel in Europe, Middle East, Africa, and India. 0 Optional: Hot dipped galvanized. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. '.1'(tauIic 1 _________________ 4.0 DIMENSIONS - k - CtoE.l C I to Cto" 0 0 0 C -b ,C to No. 001 No. 003 No. 002 No. 006 No. 001 No. 003 No. 002 No. 006 90 Elbow 45 Elbow Straight Tee Cap Approximate Approximate Approximate Approximate Actual Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each T Each inches inches inches lb inches lb inches lb inches lb DN mm mm kg mm kg mm kg mm kg 11/4 1.660 - - - - - - 0.82 0.3 DN32 42.4 - - - - - - 21 0.1 1 ½ 1.900 - - - - - - 0.82 0.4 DN40 48.3 - - - - - - 21 0.2 2 2.375 2.75 - 1.7 2.00 1.8 2.75 2.4 0.88 0.6 DN50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 3.00 3.8 DN65 76.1 76 1.5 57 1.1 76 1.7 - - 3 - - 3.500 3.38 - --- 4.0 2.50 3.1 3.38 5-3 0.88 1.2 DN80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 - - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 DN100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 141.3 124 5.7 83 3.8 124 7.1 25 1.9 5.500 4.88 12.4 3.25 8.2 4.88 15.4 DN125 139.7 124 5.6 82.6 1 3.7 124 6.9 - - 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 - - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 DN150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 140 7.9 89 5.2 140 9.9 - - 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 DN200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 8.515 6.81 23.1 - - 6.94 33.6 - - 216.3 173 10.5 - - 176 15.2 - - 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com jtauIic victaulic.com 5.0 PERFORMANCE Flow Data Size Frictional Resistance Equivalent of Straight Pipe' No. 002 Actual Elbows Straight Tee No. 001 No. 003 Nominal Outside Size Diameter 90 Elbow 45 Elbow Branch Run inches inches feet feet feet feet DN mm meters meters meters meters 1'/4 1.660 - - - - DN32 42.4 - - - - 11/2 1.900 - - - - DN40 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 DN50 60.3 1.1 0.5 2.6 - 1.1 21/2 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 3.000 4.5 2.3 11.0 4.5 DN65 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 DN80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 - 6.8 3.4 16.0 6.8 DN100 114.3 2.1 1.0 .4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 141.3 2.6 13 6.4 2.6 5.500 8.3 4.1 20.6 8.3 DN125 139.7 2.5 1.3 6.3 2.5 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 DN150 168.3 3.0 1.5 7.6 3.0 6.500 9.8 4.9 24.5 9.8 165,1 3.0 15 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 DN200 219.1 4.0 1.5 10.1 4.0 8.515 13.0 - 33.0 13.0 216.3 4.0 - 10.1 4.0 1 The flow data listed is based upon the pressure drop of Schedule 40 pipe. 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com JtsiuIic• victaulic.com 6.0 NOTIFICATIONS General Notes NOTE: When assembling FireLock EZTM couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZTM Style 009N/009H couplings, use FireLock TM No. 006 end caps containing the 'EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 0091009V/009H/009N couplings. 7.0 REFERENCE MATERIALS 1064: Victaulic® FireLock TM Rigid Coupling Style 009N 10.02 Victaulic® rireLockrM Rigid Coupling Style 005H with VjCPlus5M Gasket System 29.01: VictaLilic® Terms and Conditions of Sale User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of ny patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our webuite at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company, All rights reserved, victaulic.com \,,htauIic Victaulic® FireLockTM Installation-ReadyTM Rigid Couplings 4tauIicr Style 009N and Style 109 10.64 1.0 PRODUCT DESCRIPTION Available Sizes Style 009N: 11/4 - 12'/DN32 - DN300 Style 109: 1 ¼ - 2 ½7DN32 - 73.0 mm Pipe Material Schedule 10, Schedule 40 or specialty carbon steel pipe listed in Section 5. For use with alternative materials and wall thicknesses please contact Victaulic. Maximum Working Pressure Up to 365 psi/2517 kPa. Function Joins carbon steel pipe with grooved ends conforming to publication 25.01. Provides a rigid pipe joint designed to restrict axial or angular movement. 2.0 CERTIFICATION/LISTINGS cus z:E3 ILPCBJ J (E USTED 0104-la/36 EN 10311 Regulation (ELI) No. 305/2011 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph HE] Submitted By Date Approved Date victaulic.com 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic company. All rights reserved. 1 XAtaUlic victaulic corn 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A 536, Grade 65-4542. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) Orange enamel (North America, Asia Pacific) O Red enamel (Europe) O Optional for Style 009N.: Hot dipped galvanized Gasket: (specify choice) Grade "E" EPDM (Type A) VicPlusTM Pre-lubricated Gasket EPDM (Violet Color Code). Applicable for wet and dry (oil-free air) fire protection systems only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40°F/-40°C and above. Not compatible for use with hot water services or steam services. NOTES Reference should always be made to publication -100, vctaIlc Field Installation Handbook for gasket lubrication instructions. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to oublication 05.01, victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice) El Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial) and ASTM A563M Class 9 (metric). Track bolts and hex nuts are zinc electroplated per ASTM B633 Fe/Zn 5,-finish Type Ill (imperial) or Typeil (metric). Optional for Style 009N: Stainless steel oval neck track bolts meeting the requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel Heavy Hex nuts meeting the requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling-resistant coating.' Optional bolts/nuts are available in imperial size only. Coupling Linkage: High Strength Steel with comparable physical properties to that of the Track Bolt (ASTM A449). Linkage is zinc electroplated per ASTM B633 Fe/Zn 5, Type Ill Finish. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 2 \4taulic' victaulic.com 4.0 DIMENSIONS Style 009N Two-Bolt Installation-Ready Coupling Size Maximum Maximum Allow. - Bolt/Nut Dimensions Weight Actual Pre-assembled Joint Assembled Outside Working End Pipe End Approx. X Y X V Nominal Diameter Pressure2 Load2 Separation3 Qty. Size Z (Each) inches inches psi lb inches inches inches inches inches inches inches lb D mm kPa N mm - mm mm mm mm mm mm kg 11/4 1.660 365 790 0.10 3/8 X2 3.13 5.00 2.75 5.00 2.00 1.4 DN32 42.4 2517 3514 2.54 2 - M10x51 79 127 70 127 51 0.6 11/2 1.900 365 1035 0.10 2 3/ x 2 3.38 5.13 3.00 5.13 2.00 1.5 DN40 48.3 2517 4604 2.54 - M10x51 86 130 76 130 51 0.7 2 2.375 365 1617 0.12 2 3/8 x21/2 4.00 5.63 3.50 5.63 2.00 1.9 DN50 60.3 2517 7193 3.05 - M10x63 - 102 143 89 143 51 0.9 21/2 2.875 365 2370 0.12 2 3/ x 2½ 4.50 6.13 4.00 6.13 2.00 2.1 73.0 2517 10542 3.05 M10x63 114 156 102 1 156 51 1.0 3.000 365 2580 0.12 2 3/ex21/2 4.63 6.00 4.13 6.13 2.00 2.1 DN65 76.1 2517 11476 3.05 M10x63 118 152 105. 156- 51 1.0 3 3.500 365 3512 0.12 2 3/8 X2½ 5.13 6.75 4.63 6.75 2.00 2.3 0N80 88.9 2517 15622 3.05 - M10x63 130 1 171 117 171 51 1.0 4 4.500 365 5805 0.17 2 j'aX2h 6.00 7.88 5.63 7.50 2.13 2.9 DN100 114.3 2517 25822 4.32 M10x63 152 200 143 191 54 1.3 4.250 365 5178 0.17 2 3/8 X2½ 5.63 7.38 5.38 7.38 2.13 3.1 108.0 2517 23020 4.32 - M10x63 152 1.87 137 187 54 1.4 5 5.563 365 8872 0.17 2 ,'2 x 3 7.25 9.25 6.75 9.13 2.25 5.0 141.3 2517 39456 4.32 - M12x76 184 235 171 232 57 2.3 5.250 365 7901 0.17 2 '/2X3 6.63 9.00 6.38 9.00 2.25 4.8 133.0 2517 35106 4.32 - M12x76 168 229 162 229 57 2.2 5.500 365 8672 0.17 2 ½x3 6.88 9.25 6.75 9.13 2.25 4.9 DN125 139.7 2517 38529 4.32 M12x76 175 235 171 232 57 2.2 6 6.625 365 12582 0.17 ½X3'/4 8.38 10.38 7.88 10.13 2.25 6.0 DN150 168.3 2517 1 44469 4.32 2 M12x83 213 264 200 257 57 2.7 6.250 365 11198 0.17 ½x3¼ 7.88 10.00 7.38 9.88 2.25 5.6 159.0 2517 49753 4.32 2 - M12x83 200 254 187 251 57 2.5 6.500 365 12112 0.17 ½x3¼ 8.00 10.25 7.75 10.13 2.25 6.0 165.1 2517 53813 4.32 2 - M12x83 203 260 197 257 57 2.7 8 8.625 365 21326 0.17 51aX4 10.88 13.38 10.25 13.13 2.50 11.4 DN200 219.1 2517 94863 1 4.32 2 M16x 101 276 340 260 333 64 5.2 8.500 365 20712 0.17 /8X4 10.63 13.25 10.25 10.13 2.63 11.4 216.0 2517 55968 4.32 2 - M16x 101 270 337 1 260 257 67 1 5.2 10 10.750 300 27229 0.25 7/8 X6½ 13.75 17.00 13.25 17.13 2.75 22.6 DN250 273.0 2068 121121 6.4 2 - M22x165 349 432 337 435 70 10.3 12 12.750 300 38303 0.25 7/8 X6½ 16.00 19.00 15.50 19.13 2.75 27.6 DN300 323.9 2068 170380 6.4 2 - M22 x 165 1 406 483 394 1 486 70 12.5 2 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See the Listings/Approvals section of this publication for ratings on other pipe. The allowable pipe separation dimension shown is for system layout purposes only. Style 009N couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. NOTES When assembling Style 009N or Style 109 couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Style 009N or Style 109 couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009N or Style 109 couplings. IMPORTANT; Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling. There is no interchanging of gaskets or housings between coupling styles. Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009N or Style 109 couplings are supplied with Grade "E" Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009N or Style 109 couplings. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 3 ___________ victaulic.com 4.1 DIMENSIONS Style 109 One-Bolt Installation-Ready Coupling Style 109 Pre-Assembled Style 109 Joint Assembled Size Maximum Maximum Pipe End Bolt/Nut Dimensions Weight Actual Pre-assembled Joint Assembled Outside Working End Separation Approx. - - - Nominal Diameter Pressure4 Load4 Allowable5 Qty. Size YL YB X Z YL YB X Z (Each) inches inches psi lb inches inches inches inches inches inches inches inches inches inches lb MITI mm I kPa N mm mm mm mm mm mm mm mm mm mm kg 1 Y4 1.660 365 790 0.10 3/8 X2V4 1.88 2.50 3.13 1.88 1.88 2.63 2.75 1.88 1.4 DN32 42.4 2517 3514 2.54 M10x57 48 64 79 48 48 67 70 1 48 0.6 1½ 1.900 365 1035 0.10 3/8 x21/4 2.00 2.63 3.25 1.88 2.00 2.75 3.00 1.88 1.5 DN40 48.3 2517 4604 2.54 1 M10x57 51 67 83 48 51 70 76 48 0.7 2 2.375 365 1616 012 /8X2½ 225 288 388 200 225 313 350 200 18 DN50 60.3 2517 7193 3.05 1 M10x63 57 73 98 51 57 79 89 51 0.8 21/2 2.875 365 2370 0.12 3/8 x2½ 2.50 3.13 4.38 2.00 2.50 3.38 3.88 2.00 2.1 73.0 2517 10542 3.05 1 M10x63 64 79 111 51 64 86 98 51 0.9 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See the Listings/Approvals section of this publication for ratings on other pipe. The allowable pipe separation dimension shown is for system layout purposes only. Style 109 couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. NOTES When assembling Style 009N or Style 109 couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Style 009N or Style 109 couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009N or Style 109 couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling. There is no interchanging of gaskets or housings between coupling styles. Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009N or Style 109 couplings are supplied with Grade "E' Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the similar benefits ass FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic FlushSeal gaskets and cannot be used with the Style 009N or Style 109 couplings. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 4 \JtauIic victaulic.com 5.0 PERFORMANCE Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals6 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus" FM" VdS LPCB Actual Outside Sch. 10 Sch. 40 Sch. 10 Sch. 40 Nominal Diameter psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa DN mm bar bar bar bar bar bar 365 365 363 363 363 363 10 DN32 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 365 365 363 363 363 363 DN40 i18.3 co 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 365 365 363 363 363 363 2 2.375 DN50 60.3 2517 2517 2503 2500 2500 2500 25 25 25 25 25 25 365 365 363 363 363 363 21/2 875 2517 2517 2503 2500 2500 2500 73.0 25 25 25 25 25 25 3657 3638 363 363 3.000 2517 N/A 25038 N/A 2500 2500 DN65 25 7 25' 25 25 365 365 363 363 363 363 3 3500 0N80 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 365 365 363 363 363 363 4 DN10 0 4.500 14 .3 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 363 363 85g N/A N/A 2503 2503 N/A N/A 25 290 25 5.563 365 363 363 232 5 141.3 2000 2517 2503 2503 1600 2500 _____ 20 25 25 25 16 25 363 8 5g 3 N/A N/A 25038 N/A N/A N/A 25 290' 3638 232 363 DN125 500 2000' N/A 25038 N/A 1600 2500 139.7 20 258 25 25 300 365 363 363 232 363 6 6.625 DN150 1683 2068 2517 2503 2503 1600 2500 20 25 25 7 25 16 25 3638 6.250 N/A N/A 25038 N/A N/A N/A 159.0 25 6.500 29010 3638 363 200010 N/A 25038 N/A N/A 2500 20 258 25 6 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems -40° F/C and above. Please see the VictaulicInstallation Manual 1-009N for details concerning when supplemental lubrication is required. cULus listed for DIN 2458 (EN 10220) 2.6 mm pipe wall. 8 FM approved for BS 1387 (EN 10255) Medium 3.6 mm pipe wall. cULus listed for EN 10220 4.0 mm pipe wall. 15 cULus listed for EN 10255 4.5 mm pipe wall. ' With optional stainless steel fasteners, cULus Listed to 175p5i/1207 kPa/12 bar and FM Approved to the FM ratings shown in the above table. The stainless steel fasteners have a marking designation of 316 on the end face of the bolt. 12 cUL listed to 250 psi/1720 kPa /17 bar. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 5 \,Ltaulic' vihiilkinm 5.0 PERFORMANCE (CONTINUED) Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals6 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus" FM'1 VdS LPCB Actual Outside Sch. 10 Sch. 40 Sch. 10 Sch. 40 Nominal Diameter psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa DIN mm bar bar bar bar bar bar 300 365 363 363 232 363 8 8.625 0N200 219.1 2068 2517 2503 2503 1600 2500 20 25 25 25 16 25 290 3638 8.500 2000 N/A 25038 N/A N/A N/A 216.0 20 25 10 10.750 300 300 300 300 0N250 2730 2068 2068 2068 2068 N/A N/A 20 20 20 20 12 12.750 30012 300 250 300 DN300 206812 2068 1720 2068 N/A N/A 2012 25 17 20 6 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems 400 F/c and above. Please see the Victaulic Installation Manual 1-009N for details concerning when supplemental lubrication is required. cULus listed for DIN 2458 (EN 10220)2.6mm pipe wall. . .. 8 FM approved for BS 1387 (EN 10255) Medium 3.6 mm pipe wall: cULus listed for EN 10220 4.0 mm pipe wall. 10 cULus listed for EN 10255 4.5 mm pipe wall. It With optional stainless steel fasteners, cULus Listed to 175p5i/1207 kPa/12 bar and FM Approved to the FM ratings shown in the above table. The stainless steel fasteners have a marking designation of 316 on the end face of the bolt. 12 cUL listed to 250 psi/1720 kPa /17 bar. 5.1 PERFORMANCE Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals13 The information provided below is based on the latest listing and approval data at the time of publication. Listings! Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus FM Actual Outside Sch. 10 Sch. 40 Sch. 10 Sch. 40 Nominal Diameter psi psi psi psi inches inches kPa kPa kPa kPa ON mm bar bar bar bar 365 365 365 365 1V4 1.660 2517 2517 2517 2517 DN32 42.4 25 25 25 25 1½ 1.900 365 365 365 365 DN40 48.3 2517 2517 2517 2517 25 25 25 25 365 365 365 365 2 2.375 DNSO 60.3 2517 2517 2517 2517 25 1 25 25 25 365 365 365 365 21/2 2.875 2517 2517 2517 2517 73.0 25 25 25 25 13 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems -40° F/C and above. Please see the Victaulic Installation Manual 1-109 for details concerning when supplemental lubrication is required. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic company. All rights reserved. viefiIiinm [.1 \4taulicr victaulic.com 5.2 PERFORMANCE Specialty Pipe Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals Size Pressure Rating cULus FM psi psi inches kPa kPa Pipe Type DN bar bar 1¼-4 300 EF DN32—DN100 2068 N/A 20 300 300 EL 2068 2068 DN32—DN50 20 20 300 ET40 2068 N/A DN32—DN50 20 300 EZF 3-4 2068 N/A DN80—DN100 20 300 300 EZT 2068 2068 0N32—DN50 20 20 300 FF 1 1/2-4 2068 N/A DN4O—DN100 20 300 300 GL 2068 2068 DN32—DN50 20 20 300 300 DN32—DN100 2068 2068 M F 0 20 175 175 DN150 1205 1205 12 12 300 300 MT 2068 2068 0N32—DN50 20 20 300 MLT N/A 2068 DN32—DN50 20 300 TF 21/2-4 N/A 2068 73.0 mm—DN100 20 175 300 WGS, WGSE, WFS, WG7, WG7E, WL7 1205 2068 DN32— DN100 12 20 300 300 WLS 2068 2068 DN32—DN50 NOTES EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. EZF = EZ-Flow steel pipe manufactured by Northwest Pipe Co. EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. FE = Fire-Flo steel pipe manufactured by Youngstown Tube Co. GL = GL steel pipe manufactured by Wheatland Tube Co. MF = Mega-Flow steel pipe manufactured by Wheatland Tube Co. MT = Mega-Thread steel pipe manufactured by Wheatland Tube Co. MLT = MLT steel pipe manufactured by Wheatland Tube Co TF = Tex-Flow steel pipe manufactured by Tex-Tube Co. WG5, WG5E, WF5 = WGalweld 5, WGalweld 5E, WFlow 5 steel pipe manufactured by Wuppermann Stahl GmbH. WG7, WG7E, WL7 = WGalweld 7, Wgalweld 7E, WLight 7 steel pipe manufactured by Wuppermann Stahl GmbH WLS = WLS steel pipe manufactured by Wheatland Tube Co. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. iiifiiiIit, rnm 7 JtauIic victaulic.com 5.3 PERFORMANCE Specialty Pipe Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals Size Pressure Rating cULus FM inches psi p psi Pipe Type DN bar bar lh/4 _2½ 300 DN32 —73.0mm N/A 2068 EF _______________________________ 20 300 1½-2½ DN40 —73.0mm 2068 N/A 20 1 1/4 _2 300 Easy-Flow DN32 - DN50 N/A 2068 20 1¼-2 300 EL DN32—DN50 N/A 2068 20 300 300 ET4O 1¼-2 2068 2068 0N32 - DNSO 20 20 1¼-2 300 DN32 - DN50 N/A 2068 EZT _____________________________ 20 300 1Y2-2 DN40 - DN50 2068 N/A 20 300 300 FE 1½-2½ 2068 2068 DN40 —73.0mm 20 20 -. 1¼-2 300 GL DN32—DN50 N/A 2068 300 300 MF P/42½ 2068 2068 DN32 —73.0mm 20 20 300 300 MT 1¼-2 2068 2068 DN32 - DN50 20 20 300 300 MLT 1¼-2 2068 2068 DN32 - DN50 20 20 2½ 300 TF 73.0 mm N/A 2068 20 1 ¼-2 300 WG7,WG7E 0N32 - DN50 N/A 2068 20 300 WLS 1'-2 /4 N/A 2068 DN32 - DN50 20 NOTES EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. Easy-Flow = Easy-Flow steel pipe manufactured by Borusan Mannesmann Boru. EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. FE = Fire-Flo steel pipe manufactured by Youngstown Tube Co. GL = GL steel pipe manufactured by Wheatland Tube Co. MF = Mega-Flow steel pipe manufactured by Wheatland Tube Co. MT = Mega-Thread steel pipe manufactured by Wheatland Tube Co. MLT = MLT steel pipe manufactured by Wheatland Tube Co. TF = Tex-Flow steel pipe manufactured by Tex-Tube Co. WG7, WGJE = WGalweld 7 and WGalweld 7E steel pipe manufactured by Wuppermann Stahl GmbH. WLS = WLS steel pipe manufactured by Wheatland Tube Co. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. vithiiIirrnm jtauIicr victaulic.com 6.0 NOTIFICATIONS I AWARNING I Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designers responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. - -- 7.0 REFERENCE MATERIALS 05.01: Seal Selection Guide 25.01: Original Groove System (OGS) Groove Specifications I-009N: Installation Instructions FireLock EZ1M Rigid Coupling Style 009N 400: Victaulic Field Installation Handbook 1-109: Installation Instructions FireLockrM One-Bolt Rigid Coupling Style 109 I-ENDCAP: Victaulic End Caps Installation Instructions User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patentor other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patentor other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our websile at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com WO licctauliicr I I'l15IU .JU1JuUI 15 Style 005H with Vic-Plus TMGasket System rill-il - IF ~1 "I l i p Patented Exaggerated for clarity (PIuS \aset System Approvals/Listings: c®us IL _PC BI LISTED 104-la/02 See Victaulic Publication 10.01 for more details. [PC and VdS Approved, see notes on page 3 Product Description: FireLock Style 005H rigid Coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle-pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket. This reduces components to handle during assembly. Style 005H FireLock coupling are designed and recommended for use ONLY on fire protection systems. Vic-Plus°' Gasket System: Victaulic offers a gasket system which requires no field lubrication on wet pipe systems that are hydrostatically tested. The Vic-Plus System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements and dry pipe fire protection system notes. Job/Owner System No. Location Contractor Submitted By Date \4taulicr 10.02 Material Specifications: Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: (specify choice) Standard: Orange enamel (North America); red enamel (Europe) D Optional: Hot dipped galvanized Coupling Gasket: (specify choice) NOTE: Additional gasket styles are available. Contact Victaulic for details. U Grade "E" EPDM Type A Vic-Plus° Gasket System' EPDM (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade °E" Type A VicPIusr Gasket System, requiring no field lubrication for most installation conditions. 0 Grade 'L" silicone Recommended for dry heat, air without hydrocarbons to +350°F and certain chemical services. For dry services, Victaulic continues to recommend the use of Grade "E" Type A FlushSeal Gasket. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Standard gasket and FlushSeal gasket approved for dry pipe systems to —40°F/-40°C. Based on "typical" pipe surface conditions, supplemental lubricant is recommended for services installed below O°F/-18°C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services. Engineer Spec Section Paragraph Approved Date victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 10.02 1538 Rev M Updated 10/2014 © 2014 Victaulic Company. All rights reserved. 4taulic 1 X/ victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 Dimensions: Rated for wet and dry sprinkler systems at 350 psi/2413 kPa FA~~- ~7tsA I4~ for 1 ¼ - 4/32 - 100 mm sizes and 300 psi /2068 kPa for 4 1/4 - 8/108 - 200 mm sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005H is rigid and does not accommodate expansion, contraction or angular 9 deflection. Actual Maximum Maximum Allow. Approx. Nominal Outside Working End Pipe End ___________ Dimensions Weight X V Z Size Diameter Pressure 14 Load' Separation Bolt/Nut3 Each inches inches psi lbs. inches No. - size inches inches inches lbs. mm mm kPa N mm inches mm mm mm kg 1 1/4 1.660 350 755 0.05 2.75 4.50 1.88 1.2 32 42.4 2413 3370 1.2 2-3/8 X2¼ 70 114 48 0.5 11/2 1.900 350 990 0.05 2-%X2'/4 3.00 4.75 1.88 1.2 40 48.3 2413 4415 1.2 76 121 48 0.5 2 2.375 350 1550 0.07 3.50 5.25 1.88 1.6 50 60.3 2413 6900 1.7 2- /8 x 21/2 89 133 48 0.7 21/2 2.875 350 2270 0.07 4.00 5.75 1.88 1.9 65 73.0 2413 10110 1.7 2-'/,x2½ 102 146 48 .09 76.1 mm 3.000 350 2475 0.07 2-3/8 X2½ 4.13 5.75 1.88 1.9 76.1 2413 11010 1.7 105 146 48 0.9 3 3.500 350 3365 0.07 4.63 6.13 1.88 2.1 80 88.9 2413 14985 1.7 2-3/4 x21/2 118 156 48 1.0 4 4.500 350 5565 0.16 5.75 7.25 2.13 3.1 100 1 2413 2-3/8X2½14.3 24770 4.1 146 . 184 54 - 1.4 108.0 mm 4.250 300 4255 0.16 X2 ½ 63 5,63 . 725 2.13 3.1 108.0 2068 18940 4.1 143 184 54 1.4 5 5.563 300 7290 0.16 6.88 9.00 2.13 4.5 125 141.3 2068 32445 4.1 2-½x3 175 229 54 2.0 133.0 mm 5.250 300 6495 0.16 2-½x2'A 6.63 9.00 2.13 4.5 133.0 2068 28900 4.1 168 229 54 2.0 139.7 mm 5.500 300 7125 0.16 2-½x234 6.88 9.00 2.13 4.8 139.7 2068 31715 4.1 175 229 54 2.2 6 6.625 300 10340 0.16 8.00 10.00 2.13 5.0 150 168.3 2068 46020 .4.1 2-½x3 203 . 254 53 2.3 159.0 mm 6.250 300 9200 0.16 2-½x2'% 7.63 10.00 2.13 5.5 159.0 2068 40955 4.1 194 254 54 2.5 165.1 mm 6.500 300 9955 0.16 2-½x3 8.15 10.00 2.13 5.5 165.1 2068 44295 4.1 207 254 54 2.5 8 8.625 300 17525 0.19 10.50 13.14 2.63 11.3 200 219.1 2068 78000 4.8 2-5/8X4¼267 1 334 1 67 5.1 1 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications, contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1½ times the figures shown. 2 The allowable pipe separation dimension shown is for system layout purposes only. Style 005H couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 3 Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. 4 Style 005H couplings are VdS and LPC Approved to 16 Bar/235 psi. 10.02 1538 Rev M Updated 10/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 \tauIjC victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 Listings/Approvals: The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Related Working Pressure psi Related Working Pressure psi Related Working Pressure psi Pipe Sch. Size inches UL ULC FM Pipe Sch. Size inches UL ULC FM Pipe Sch. Size inches UL ULC FM 5 11A-3 175 175 175 EL 11/4 -2 300 N/A N/A MT 11/4 _2 300 N/A N/A 11/4-3 350 350 350 1 El 11/4-2 300 N/A N/A SIF 11/4-4 N/A N/A 300 10,40 5-8 300 300 300 EZ 4-6 3006 N/A 300 Steady11/4 -2 N/A N/A 300 BLT 11/4 -2 300 300 N/A FF 11/4-4 N/A N/A 300 IF 3-8 N/A N/A 300 DF 11/4 -4 300 300 300 GAL -7 11/4 -2 300 N/A N/A WLS 1¼ — 2 300 300 N/A Dl 11/4-2 300 300 N/A MLT 11/4-2 300 N/A N/A I XL 1¼-3 300 300 300 EF 1 11/4-4 1757 N/A 175 MF 11/4-4 300 N/A 300 5 FM approved for service in 1 1/2 - 4" pipe. 6 UL Listed for service up to 4" pipe only. 7 UL Listed for service up to 3 only. Installation Note Reference should always be made to the 1100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications. All products the product you are installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data, and are available in PDF format Victaulic reserves the right to change product specifications, designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic® is a registered trademark of Victaulic Company. 10.02 1538 Rev M Updated 10/2014 © 2014 Victaulic company. All rights reserved. victauliccom 3 Aictaulic:r Victaulic® Flexible Coupling 'JtuIic Style 75 06.05 yww 1 - 87DN25 - DN200 1.0 PRODUCT DESCRIPTION Available Sizes 1 - 87DN25 - DN200 Pipe Material Carbon steel Stainless steel Maximum Working Pressure Accommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) up to 500 psi/3447 kPa/34 bar v Working pressure dependent on material, wall thickness and size of pipe Application Joins standard roll grooved and cut grooved pipe, as well as grooved fittings, valves and accessories Provides a flexible pipe joint which allows for expansion, contraction and deflection Up to 50% lighter in weight than standard Victaulic Style 77 or Style 177N flexible couplings 2.0 CERTIFICATION/LISTINGS _ NOTES Download publication 10.01 for Fire Protection certifications/Listings Reference Guide. See gublicabon 02.06: victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date i,i+i ihr .nn1 06.05 1470 Rev P Updated 10/2017 © 2017 victaulic company. All rights reserved. 1 '-~. Ai-ct-a-ulicr victaulic.com 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) El Standard: Orange enamel El Optional: Hot dipped galvanized El Optional: Contact Victaulic with your requirements for other coatings. Gasket: (specify choice') El Grade "E" EPDM EPDM (Green stripe color code). Temperature range —30"F to+230"F/-34"C to +110"C. May be specified for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot +180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES. El Grade "1" Nitrile Nitrile (Orange stripe color code). Temperature range —20"F to +180"F/-29"C to +82"C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; not compatible for hot dry air over +140°F/+60°C and water over +150°F/+66°C. NOT COMPATIBLE FOR USE WITH HOT WATER. El Others For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide -ElastomericSeal Construcibr. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice2) El Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - heavy hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FE5, finish Type III (imperial) or Type II (metric). El Optional (imperial): Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel heavy nuts meeting the mechanical property requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating. 2 Optional bolts/nuts are available in imperial sizes only. 06.05 1470 Rev P updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com \,/t9UIiC victaulic.com 4.0 DIMENSIONS Style 75 Pipe End Deflection from Size Separation3 Centerline3 Bolt/Nut Dimensions Weight Actual Outside Approx. Nominal Diameter Allowable Per Cplg. Pipe Qty. Size X V Z (Each) inches inches inches inches/ft. imperial inches inches inches lb DN mm mm Degrees mm/m - metric mm mm mm kg 1 1.315 0-0.06 0.57 2 3/ax2 2.38 4.27 1.77 1.3 0N25 33.7 0-1.6 2 - 43' 48 - M10x51 61 108 45 0.6 1 1/4 1.660 0-0.06 2 - 10 0.45 2 3/sx2 2.68 4.61 1.77 1.4 DN32 42.4 0-1.6 38 M10x51 68 117 45 0.6 1 1/2 1.900 0-0.06 0.40 2 3/sx2 2.91 4.82 1.77 1.5 DNJ4O 48.3 0-1.6 1 - 56' M10x51 74 122 45 0.6 2 2.375 0-0.06 1 - 31' 0.32 2 %x2 3.43 5.22 1.88 1.7 DN50 60.3 0-1.6 26 M10x51 87 133 - 48 - 0.8 21/2 2.875 0-0.06 0.26 2 /8 x 2 3.88 5.68 1.88 1.9 73.0 0-1.6 1 - 15' 22 M10 x51 98 144 48 0.9 3.000 0-0.06 1 - 12' 0.26 2 3/8x2 4.00 5.90 1.88 1.9 DN65 76.1 0-1.6 22 M10x51 102 150 48 0.9 3 3.500 0-0.06 1 - 2' 0.22 2 ½ x 2/4 4.50 7.00 1.88 2.9 DN80 88.9 0-1.6 18 M12x70 114 178 48 1.3 31/2 4.000 0-0.06 0 4 0.19 2 ½X2 3/4 5.00 7.50 1.88 2.9 DN90 101.6 0-1.6 16 M12x70 127 191 48 1.3 4 4.500 0-0.13 1 - 36' 0.34 2 ½X2 3/4 5.80 8.03 2.13 4.1 DN100 114.3 0-3.2 28 M12x70 147 204 54 1.9 4.250 0-0.13 1 0.35 2 1/ x 2 3/4 5.55 7.79 2.13 3.7 108.0 0-3.2 29 M12x70 141 198 54 1.7 5.000 0-0.13 1 - 26' 0.25 2 /8 x 3¼ 6.13 9.43 2.13 5.5 127.0 0-3.2 21 M16x83 156 240 54 2.5 5 5.563 0-0.13 1 - 18' 0.27 2 5/8X3¼ 6.88 10.07 2.13 5.8 141.3 0-3.2 23 - M16x83 175 256 54 1 2.6 5.250 0-0.13 0.28 2 5/3x31/4 6.55 9.37 2.13 6.0 133.0 0-3.2 1 - 21' 24 - M16x83 166 238 54 2.7 5.500 0-0.13 0.28 2 5/sx3¼ 6.80 9.59 2.13 6.3 DN125 139.7 0-3.2 1 - 18' 24 - M16x83 173 244 54 2.9 6.000 0-0.13 0.21 2 5/8X3¼ 7.38 10.48 1.88 6.2 152.4 0-3.2 1 - 12' 18 - M16x83 187 266 48 2.8 6 6.625 0-0.13 0.23 2 ¼x3¼ 8.00 11.07 2.13 7.0 DN150 168.3 0-3.2 1 - 5' 18 M16x83 203 281 54 3.2 6.250 0-0.13 1 - 9' 0.24 2 5/sx3¼ 7.63 10.49 2.13 6.8 159.0 0-3.2 20 M16x83 194 266 54 3.1 6.500 0-0.13 1 -7' 0.23 2 5/ x 3 1/4 7.84 10.66 2.08 6.6 165.1 0-3.2 58 - M16x83 199 271 53 3.0 8.515 0-0.13 0.18 ~x4¼ 10.19 13.75 2.32 13.2 216.3 0-3.2 0 - 51' 46 2 - M20 108 259 350 59 1 6.0 8 8.625 0-0.13 0 50' 0.18 2 34x41/4 10.34 13.97 2.13 1 12.4 DN200 219.1 0-3.2 - 14 M20x 108 263 355 59 5.6 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 3%_3 1/2 /DN20 - DN90; 25% for 4'/DN100 and larger. NOTE Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. 06.05 1470 Rev P Updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com C] '4J Lictaullilor victaulic.com 5.0 PERFORMANCE Style 75 Size Maximum Actual Outside Working Maximum Nominal Diameter Pressure4 End Load4 inches inches psi lb ON mm kPa N 1 1.315 500 680 DN25 33.7 3447 3,025 1 ¼ 1.660 500 1080 DN32 42.4 3447 4,805 1 ½ 1.900 500 1420 0N40 48.3 3447 6,320 2 2.375 500 2215 DN50 60.3 3447 9,860 21/2 2.875 500 3245 73.0 3447 14,440 3.000 500 3535 DN65 76.1 3447 15,730 3 3.500 500 4800 DNSO 88.9 3447 21,360 31/2 4.000 500 6300 DN90 1 101.6 3447 28,035 4 4.500 500 7950 ON100 114.3 3447 35,380 4.250 450 6380 - 108.0 3103 28,395 5.000 450 8820 127.0 3103 39,250 5 5.563 450 10935 141.3 3103 48,660 5.250 450 9735 133.0 3103 43,325 5.500 450 10665 DN125 139.7 3103 47,460 6.000 450 12735 152.4 3103 56,670 6 6.625 450 15525 DN150 168.3 3103 69,085 6.250 450 13800 159.0 3103 61,405 6.500 450 14930 165.1 3103 66,412 8.515 450 25625 216.3 3103 1 113,986 8 1 8.625 450 26280 DN200 219.1 1 3103 116,945 Working Pressure and End Load are total, from all internal and external loads, based on ANSI B36.10 sized carbon steel pipe, grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. NOTE WARNING FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. 06.05 1470 Rev P Updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com El Lctaull ice victaulic.com 6.0 NOTIFICATIONS A.WARNING Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or property damage. NOTICE Victaulic RX grooving rolls must be ordered separately. They are identified by a silver color and the designation RX on the front of the roll sets. 7.0 REFERENCE MATERIALS 02.06 VictaulicW Potable Water Approvals ANSI/NSF 05.01 Victaulic® Seal Selection Guide Elastomeric Seal Construction 06.15 Victaulic® Pressure Ratings and End Loads for Viclaulic Couplings on Steel Pipe 10,01: Victaulic® Products for Fire Protection Pipings Systems - Regulatory Approval Reference Guide 17.01: Victaulic® Pipe Preparation for Use on Stainless Steel Pipe With Victaulic Products 17.09: Victaiilic® Ductile Iron Grooved Couplings Performance Data for Stainless Steel Pipe 25.01: Victaulic® Standard Groove Specifications 26.01: Victaulic® Design Data 29.01: Victaulic® Terms and Condit ons of Sale -100: Victaulic® Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination onto the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any ether document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sate, installation guide, or this disclaimer, Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/sr methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 06.05 1470 Rev P Updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 61 Mechanical-I® Bolted Branch Outlets ® ILPCBI VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N Victaulic MechanicalT® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-I outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-I Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-I in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-I unit. See page 8 for further information. Ja STYLE 920 CROSS PATENTED STYLES 920 AND 920N MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "1" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Approved Date www.victaulic.com vlcTAuuc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTALILIC COMPANY. ALL RIGHTS RESERVED. REV 0 JtauIicr STYLES 920 AND 920N DIMENSIONS Y GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½750 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical-I® Bolted Branch Outlets I JL.VZ I iiFi1 = OL 2 ½ (a) 920N I 500 1 50 200 253 1.61 5.35 2.75 3.1 50 15 3450 64 70 1.5 ~ (a) U 920N 500 .50 .97 2.53 1.61 5.35 2.75 3.1 20 38.1 64 -41 136 70 1.5 1(a) U 920N 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 3450 38.1 47 64 - 41 136 70 1.4 11/4 (a) tn 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1½ (a) to 920N 500 1.75 2.03 2.75 3.12 1,61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 j 2½ x ½ (a) § ' 920N 500 1.50 2.21 2.74 1.82 5.64 2.75 3.0 65 15 3450 38.1 56 70 - 46 143 70 1.4 3/4 (a) §U 920¼ 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 46 1(a) §U 920¼ 500 1.50 2.06 2.74 1.82 5.64 2.75 2.9 25 3450 38.1 52 70 - 46 143 70 1.4 - 11/4 t (a) U 920N 500 1.75 2.30 3,00- 3.25 1382 6.29 3.00 - 3.5 3.2 32 3450 44.5 . 58 .76 83. 46 160 76 .. 1.7 1.5 1 ½ I' (a) U 920¼ I 500 2.00 2.28 3.00 3.25 1.82 6,26 3.25 3.6 3.3 40 J 3450 50.8 58 76 1 83 46 159 83 1.7 1.6 ½ (a) 76.1 x 920N 300 1.50 2.22 2.75 - 2.25 6.46 3.18 3.9 - 15 2065 38.1 56 70 57 1 164 1 81 1.8 3/4 (a) 920N 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 20 * 2065 38.1 * 56 70 - 57 164 81 1.8 - 1(a) 920¼ 300 1.50 2,07 * 2.75 - 2.25 6.46 3.18 3.8 - 25 2065 38.1 53 1 70 57 164 81 1.7 1¼ (a) a920¼ 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 1,5, 1½ (a) 0 920N 500 200 2.28 3.00 3.31 1.92 6.29 125 3.5 3,3 40 3450 50.8 58 76 84 49 160 83 1.6 '1.5 3 112 (a) D 0N 500 1.50 2.52 3.05 2.28 6.15 2.75 3.4 80 15 3450 38.1 64 78 - 58 156 70 1.6 3/4 (a) o 920N lsoo 1.50 2.49 3.05 2.28 6.15 2.75 3.4 20 3450 38.1 63 78 - 58 156 70 1.6 - 1(a) 920N 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 '' 58 156 70 1.6 - 1 ¼ (a) 'to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32(b) 3450 435 65 83 90 58 156 76 LB LB 1½ (a) tU 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 fl 89 90 58 156 83 2 (a) U 920¼ 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 635 70 89 90 58 172 99 23 2.1 31/2 2 500 2.50 3.00 3.75 2.44 6.72 3.88 3.8 _ 90 50 3450 63.5 76 95 , 62 171 99 LB TABLE CONTINUED ON PG 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). 'f Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2' BSPT clearly on order. § Vds approved for fire protection services U LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com '\J14taUIic" /ICTAULIC IS REGISTERED TRADEMARK OF vlcTAuuc COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02 2 , REV 0 CARBON STEEL PIPE - HOLE CUT PRODUCTS I I.V1 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N App Dimensions Weight Each TABLE CONTINUED FROM PAGE 2 4 ½ (a) a '< 920N 500 150 3 03 3.56 2.69 7.01 2.75 3.7 100 15 3450 38.1 77 90 - 68 178 70 1.8 '/4 (a) U 920N 500 1.50 300 3.56 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 - 68 178 70 - 1.8 1(a) u N 500 1.50 2.88 3.56 269 7.01 - 2.75 3.6 25 3450 38.1 73 90 - 68 178 70 - 1.8 1 ¼ (a) to 32 (b) 500 920N 3450 1.75 44.5 3.08 78 3.78 96 4.00 102 2.69 7.01 68 178 3.00 76 4.0 36 1.9 1.8 1 1/2 (a) to 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 9 3450 50.8 83 102 102 68 178 83 2.0 1.9 2 (a) to N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 46 50 3450 63.5 83 102 102 68 178 99 21/2 (a) t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69 73 102 102 68 6 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 4.00 2.69 7.34 4.63 6.4 3450 69.9 73 1 102. 68 2.9 118 3(a).t 920 -500 3.50 3.31 .50 4 412 .2,69 .7.73 5.12 8.4 6.4 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 1¼ (a)0 08.0 x N 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 32 , 3450 ± _i_ 96 67 194 78 2.3 1 ½ (a)U 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 - 40 3450 50.8 83 102 - 67 194 83 2.3 2 (a) 920 N 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 50 3450 63.5 83 102 - 67 194 102 1.9 1 - 500 2.75 2,88 4.00 4.00 2.63 7.64 4.29 1 8.0 7.8 761 mm 920 3 (a) 3450 500 69.9 73 3.50 3.31 102 4.50 102 67 194 109 ) 3.6 L 3.5 920 4.50 2.63 7.63 4.88 6.8 6.5 80 -- 920 3450 8884 114 114 67 194 124 31 10 5 1 ½ (a) t 500 2,00 1 4.03 4.75 4.75 316 9.70 3.69 7.4 7.6 125 40 3450 50.8 11102 L 121 80 246 2 2 (a) t 50 920 500 - 3450 2.50 4.00 63.5 • 122 4.75 121 4.75 121 3.16 9.70 4.38 80 246 8.2 8.0 21/2 (a) t 500 920 2.75 3.63 4.75 4.75 3,16 9.70 4.63 8.3 7.9 65 3450 69.9 92 121 121 80 246 1 118 3.8 3.6 2.75 3.75 69 95 - I 4.75 3,16 9.70 4.6 - 8.0 80 246 118 -3.6 7 61 mm U 500 920 3450 3 (a) t 9)0 500 3.50 ' 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 500 88.997i127 2.50 3.75 4,50 118 80246 135 3.17 8.00 3.88 8.0 3.8 4.0 2 133. x 2 N 9 0 3450 63.5 95 114 81 3.6 3 920 500 3.50 I 3.81 5.00 3.00 9.46 5.31 8.0 80 3450 I 88.9 97 127 - 76 240 135 - 3.6 TABLE CONTINUED ON PG. 4 DIMENSIONS Now I, II er-.010W** 9 FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psiI3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. pry 0 ul IC 11.02 3 CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Y ~ r-F- 1 GROOVED OUTLET - Y - r -r- z ~v FT 1-14, FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Dimensions I iTcii III TABLE CONTINUED FROM PAGE 3 1 ½ t 139.7 x 920N 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 40 3450 508 96 114 - 84 209 83 3.2 - 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 9.0 50 3450 63.5 95 114 - 84 209 99 4.1 - 6 1¼ (a) 920N 500 1.75 4,43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 32 (b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 1½ (a) tC1920N 500 2.00 4.40 5.13 5.13 3,79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a) to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 I 2.7 2.5 2½ 9, 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 65 10 3450 1 69.9 110 1 130 1 130 94 267 118 3.8 3.4 76.1 mm a 920 500 1 2.75 4.15 j 5.21 3.69 10.51 4.63 8.4 3450 69.9 105 - 132 94 1 267 - 118 3.8 3 (a)t 920 500 3.50 4.31 5.50 5.13 3,69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 . 267 135 4.5 3.8 4(a) to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 1 ½ (a) 159.0 x 020N 500 200 4.41 5.13 3.63 9.40 3.25 1 7.8 40 3450 50.8 -112 130 92 239 83 J 3.5 2 (a) 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 50 I 3450 63.5 111 130 - 92 239 99 3.6 - 76mm . .1 92 0 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 mm 1080 920 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 - 137 92 239 155 - 4.5 920 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 100 3450 114.3 1 96.80 1 146 - 92 239 1 159 8.2 - TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2½ BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com j4tauiic vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAUUC COMPANY. ALL RIGHTS RESERVED. 11.02 4 REV 0 CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS op 10~1 ! ; 10 ags v M. M, GROOVED OUTLET * FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2'750 x 15mm through 8 x 4/200 x 100 mm -J IJ[id1Fld. Approx Weight _____________ ! 14 + I[Th TABLE CONTINUED FROM PAGE 4 X 1651 1 920N 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 25 3450 38.1 99 116 . 96 237 70 3.6 - 11/4 920N 500 1.75 4.43 5.13 3.79 9.34 I 3.25 8.4 - 32 3450 44.5 113 130 96237 83 3.8 1½ (a) to 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 2 (a) t 90N 500 2.50 4.38 5.13 5.13 3.79 9.341 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 1 99 53 53 76.1 mm 90 500 2.75 4,01 5.13 . 5.21 3.63 10.51 4.63 8.6 7.6 _3450 69.9 flO 130 132 92 267 118 53 1 53 3(a) 'I- 0 920 500 3.50 4.31 5.50 I 5.13 3.63 1031 5.31 10.2 8.4 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 4(a) to 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 x 2 (a) t 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 1 11.6 200 50 3450 69.9 , 138 157 159 122 316 114 5.3 5.3 21/2 (a)t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 .. 4.50 11.6 11.6 65 _114 53 53 76.1 mm a 920 500 2.75 5.25 - 6.25 4.81 1 12.42 ;' 4.56 11.6 3450 699 133 - I 159 L 122 ----_ 316 116 - 53 3(a) to 920 500 3.50 5.31 6.50 1 6.50 4.81 12.42 1 5.31 12.6 11.6 80 3450 889 135 165 1 165 122 316 135 5] 53 4(a) to 920 500 4.50 , 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100 3450 114.3122 1 171 _162 122 _316159 6.9 .5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.' (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2' BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. pry IIiIIIIACCtaulicr CARBON STEEL PIPE - HOLE CUT PRODUCTS I I.0 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-V5 fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C, and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. ®_ _ Exaggerated for clarity Formulas for C,K, Values: = Q2 Where: Q = Flow (GPM) = Pressure Drop (psi) Q = C x C = Flow Coefficient AP = Q2 K 2 Q = K x Where: Q = Flow (m3/hr) = Pressure Drop (Bar) K = Flow Coefficient Equivalent Length of Outlet Size Sc hedule 40 Carbon Steel Pipe OUTLET SIZE for-My. ~ik tHi'IA!L1J '/2 0.840 11 15 21.3 - 2 - 94 34 1.050 16 20 26.7 - - 13.7 1.315 21 3 8 25 33.7 - 1.8 1 1% 1.660 50 48 32 42.7 5 /2 6 42.9 41.1 1 ½ 1.900 I1 53 53 40 48.3 11 45.4 45.4 2 2.375 112 104 50 60.3 9 10 /2 96 89.1 2½ 2.875 . . 119 iSO 65 73.0 20 12 /2 102 128.5 3.000 161 76.1 mm 16 - - 76.1 138.1 3 3.500 , 249 237 80 L 88.9 14 15 /2 213.4 203.1 4 4.500 22 421 401 100 114.3 20 360.8 343.6 Hazen-Williams coefficient of friction is 120. ' Pipe with a wall thickness of 0.165in14.2mm. 1 , FireLock Innovative Groove System (IGS) outlet www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. ldicctauhlc~ 11.02 6.1 REV 0 CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size Outlet Size Pipe Approval Agency Rated Working Pressures — psi/kPa 10,40 400 400 400 290 232 362 21/2-6 2.875 - 6.625 All 65-150 73.0-168.3 2755 2755 2755 - 1999 1599 2496 21/2-4 2.875 - 4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2 - 4 2.875 - 4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 1 2065 2065 2065 1999 1599 2496 6 6.625 4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 34 1 3040 300 300 300 290 232 362 150 ' 168.3 - ' 2065 2065k 2065 1999 1599 2496 8 8.625 21/2 10,40 400 - - - 45 - 200 219.1 2755 8 8.625 4 10 300 I 250 ..... .1000 . ••_ .. . . -. 200 219.1 ' 2065 I 1724 1000 8 8.625 3040 300 - 300 - 145 - 200 219.1 ' 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DE refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4 - 87100 - 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap Il Mechanical-T unit is a full port ball valve which can be mounted on 4/100mm, 5'7125 mm, 6/150mm and 8/200 mm diameter pipe. The Style 931 comes with a 21/2,765 mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCl) in accordance with safety codes. For more information, refer to publication 24.01 www.victaulic.com vIcTAULIc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 vIcTAULIc COMPANY. ALL RIGHTS RESERVED. RFV fl AC_ taui IC° Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV UPDATED 11/2018 vICTAuLIc IS REGISTERED TRADEMARK OF vlcrAuuc COMPANY. 02018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. x Ate-ta-ulicr 11.02 I.. Victaulic® FireLockTM Outlet-T X.4uhc° Style 922 10.52 1.0 PRODUCT DESCRIPTION Available Sizes as 1 1/4 -2 1/2"/DN32—DN65 as Threaded Outlet Sizes: 1/2"/DN15, 3/4'/DN2O, and 1/DN25 NOTE IGS Grooved 170N25 Outlets available for this product. See publication 10.54. Maximum Working Pressure 300psi/2068kPa/21 Bar Application Provides a convenient method of incorporating outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products Pipe Material Carbon steel Contact Victaulic for use on additional pipe types and wall thicknesses 2.0 CERTIFICATION/LISTINGS C®US f LPCBI @' USTED NOTES See Section 7.2 REFERENCE MATERIALS for additional certification information. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date SIi,-f2III4- ((n1 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. 1 '\'ACCtaUIii[:f victaulic.com 30 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) U Orange enamel (North America, Latin America, Asia Pacific). U Red enamel (Europe). U Optional: Contact Victaulic with your requirements for other coatings. Gasket': U Grade "E" EPDM (Type A) EPDM (Violet color code) Applicable for wet and dry (oil-free air) sprinkler services only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40FI-40°C and above. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: U Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex flange nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex flange nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type Ill (irnperial)or Type ll(metric). . 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 4tauIic' victaulic.com 4.0 DIMENSIONS Style 922 u-I Style 922 Size - Bolt/Nut Dimensions Weight Nominal Actual Approximate Run x Branch FPT2 Outside Diameter Qty. Size T3 V W Y Z (Each) inches inches inches inches inches inches inches inches lb DN mm - mm mm mm mm mm mm kg 1¼ 1/2 1.660 0.840 1.30 1.83 1.10 3.87 2.56 1 DN32 X DN15 42.4 21.3 2 lii 33 47 28 98 65 -0.5 1.28 1.83 1.10 3.87 2.56 1 3/4 1.050 2 X 1 DN20 26.9 33 47 28 98 65 0.5 1.52 2.18 1.10 3.87 2.56 1 1 1.315 DN25 2 Xl 39 1 55 28 98 65 0.5 11/2 ½ 1.900 0.840 1.42 1.95 1.22 4.08 2.56 1 40 DN15 48.3 21.3 2 x1 36 50 31 104 65 0.5 1.40 1.95 1.22 4.08 2.56 1 3/4 1.050 2 x.1 DN20 26.9 36 50 31 104 65 0.5 1.64 2.30 1.22 4.08 2.56 1 1 1.315 DN25 2 X 1 42 58 31 104 65 0.6 2 1/2 2.375 0.840 1.66 2.19 1.46 4.60 2.56 1 50 DN15 60.3 21.3 2 x1 42 56 37 117 65 0.6 1.64 2.19 1.46 4.60 2.56 1 3/4 1.050 DN20 - 26.9 2 X 1 42 56 37 117 65 0.6 1.88 2.54 1.46 4.60 2.56 2 1 1.315 DN25 2 Xl 48 65 37 117 65 0.7 21/2 1/2 2.875 0.840 1.91 2.44 1.71 5.40 2.56 2 DN15 73.0 21.3 2 49 62 43 137 65 0.7 1.89 2.44 1.71 5.40 2.56 2 1/4 1.050 DN20 26.9 2 X 1 48 62 43 137 65 0.7 2.13 2.79 1.71 5.40 2.56 2 1 1.315 DN25 2 Xl 54 71 43 137 65 0.7 DN65 1/2 3.000 0.840 1.91 2.44 1.71 5.50 2.56 2 DN15 76.1 21.3 2 x1 49 62 43 140 65 0.7 1.89 2.44 1.71 5.50 2.56 2 3/4 1.050 DN20 26.9 2 X 1 48 62 43 140 65 0.7 2.13 1.71 5.50 2.56 2 1 1.315 DN25 2 X 1 54 :::2.79: 71 43 140 65 0.8 2 Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Refer to the specific literature for these types of special male-threaded products for guidance and possible limitations for use. Failure to verify Suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 3 'NJtauIicY .1;,. 5.0 PERFORMANCE Style 922 Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120)4 Run Size x Outlet Size Threaded Grooved5 inches feet feet DN meters meters 11/4 1 8.5 12.5 DN32 DN25 2.6 3.8 11/2 1 8.5 12.5 DN40 DN25 2.6 3.8 2 1 8.5 12.5 DNSO DN25 2.6 3.8 21/2 1 8.5 12.5 0N25 2.6 3.8 1 8.5 12.5 DN65 DN25 2.6 3.8 Hazen-Williams coefficient of friction is 120. F FireLockTM Innovative Groove System (IGS) outlet 6.0 NOTIFICATIONS WARNING 0 Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Dimensions Minimum Hole Diameter/ Maximum Hole Diameter! Hole Saw Size Hole Saw Size inches inches mm mm All Outlet Sizes 1 3(6 ¼ 1 30 32 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 4 '%/ttauiic victaulic.com 7.1 REFERENCE MATERIALS Size Services Pressures per Regulatory Approvals and Listings6 Nominal UL ULC FM VdS LPCB CNBOP inches psi psi psi psi psi psi DN kPa kPa kPa kPa kPa kPa 1¼x'/a 300 300 300 232 232 232 DN32XDN15 2068 2068 2068 1600 1600 1600 1 1/4 X 3/4 300 300 300 232 232 232 DN32XDN20 2068 2068 2068 1600 1600 1600 1¼x1 300 300 300 232 232 232 DN32XDN25 2068 2068 2068 1600 1600 1600 1½x'/2 300 300 300 232 232 232 DN40XDN15 2068 2068 2068 1600 1600 1600 1½x% 300 300 300 232 232 232 DN40XDN20 2068 2068 2068 1600 1600 1600 1½x1 300 300 300 232 232 232 DN40XDN25 2068 2068 2068 1600 1600 1600 2x½ 300 300 300 232 232 232 DN50XDN15 2068 2068 2068 1600 1600 1600 2x3/4 300 300 300 232 232 232 DN50X20 2068 2068 2068 1600 1600 1600 2x1 300 300 300 232 232 232 DN50XDN25 2068 2068 2068 1600 1600 1600 21/2 x1/2 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 2½x3/4 300 300 300 232 232 232 2068 2068 2068 1600 1600 - 1600 21/2 X1 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 300 232 232 232 DN65XDN15 - - 2068 1600 1600 1600 300 232 232 232 DN65XDN20 - - 2068 1600 1600 1600 300 232 232 232 DN65XDN25 - - 2068 1600 1600 1600 6 Pressures listed in this chart are based upon standard wall pipe. Approved and Listed pressures may vary by pipe schedule. NOTE Consult regulatory agency websites for details and the most recent regulatory information. 7.2 REFERENCE MATERIALS 05.01: Victaulic Seal Selection Guide 29.01: Victaulic Terms and Conditions of Sale -100: Installation Instructions -922: Installation Instructions FireLockrM Outlet-I User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patentor other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as recommendation for the use of such material, product, service, or design in the infringement of any patentor other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on Wechat, Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks - Victaufic and all other Victaulic marks are the trademarks or registeredtrademarks of Victaulic Company, and/or its affiliated entities, is the U.S. and/or other countries. 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.cnm 5 1lii ll,,A_C_ta_U1iCr J www.anvilstar.com MERIT WeIdMiserTM Tee-Let® Welding Outlet Fittings Unified Design TM Series Merits Unified Design Series carries all important design considerations into its entire line of welding branch outlet fittings. Merit® WeldMiserTM Tee-Lets® are designed and Manufactured to reduce the amount of weld required to install the Tee-Lets on thin wall or proprietary flow pipe. Typically only one weld-pass completes the installation. Merit Tee-Lets install with less weld volume than any other brand of welding outlet fittings for fire sprinkler applications. To accomplish this: - -- - - The contoured end of the fittings employs a reduced outside diameter. Two major advantages are immediately apparent: The thinner wall on the contoured end permits welding temperatures to be matched to the thickness of the branch line or main thereby insuring complete penetration without cold welds, weld roll-off, burn-through or excessive distortion. On smaller sizes a heavier section is maintained on the threaded end of the fitting. This protects the threads from damage during shipping and handling prior to installation as well as from weld distortion. Each outlet size 11/2 and larger, whether male or female threaded, cut grooved or beveled requires the same hole size in the header pipe. This simplifies the installation process. General Specifications Tee-Let welding outlet fittings are manufactured from highly weldable steel which conforms to the chemical and physical requirements of ASTM A-53, Grades A or B Type E Ease of installation is assured when automatic welding equipment is used to install Merit Tee-Lets. Threads are cut in accordance with the requirements of ANSI 131.20.1, national standard for tapered pipe threads, or 150-7-1 threads are available. Tee-Let threaded and grooved welding outlet fittings are ULJULC Listed and FM Approved for use in the fire sprinkler systems installed in accordance with the requirements of NFPA Bulletin 13. They are rated for 300 PSI operation in fire sprinkler systems, and higher pressures in other non-critical piping systems. Tee-Lets are offered in a wide variety of header sizes. The consolidated header sizes shown in the following charts allow the fittings to be installed on more than one header size, permitting the first size listed to fit the header perfectly, while a small gap along the longitudinal center line of the header will appear for the second size listed. Merit® Weld-Miser1M Tee-Lets® are identified by a lot number that provides full traceability per ISO 9000 specifications. For Your Piping Systems Specify Weld-Miser TM Tee-Let® Branch Outlet Fittings shall be Merit Weld-Miser Tee-Let, Lightweight forged steel, employing low weld volume profile to provide for full penetration welds with minimum burn through and pipe distortion on Schedule 5 thru 10, proprietary thin wall, and standard wall pipe. Threads are to be ANSI B1.20.1, or ISO-7-1, and the bore of the fittings calculated to improve flow. Welding outlets to be UL Listed, FM Approved for use conforming to NFPA, Bulletin 13 and pressure rated for 300 PSI maximum. How to Order - Use either of the following methods for ordering Merit® WeldMiserTM Tee-Let®. Method No. 1 Method No. 2 Specify quantity desired followed by the part Use the following system: number shown in the "dimensions" chart for the type and size of outlet desired. - Type Merit Steel Quantity Part Number Quantity * Outlet Size Header Size Weight End Tee-Let Material + + Always Column "A' Insert size Sch. 10 A - Female Thread order a few of Chart consolidation Standard B - Male Thread more than from Column C - Cut Groove actually "B" of chart. C/R - Roll Groove required for the job. —2— iNJtLStar Fire Products Division :' ' MERIT WeIdMiserTM Tee-Let® Welding Outlet Fittings For Fire Protection & Other Low Pressure Piping Systems Merit Weld-Miserly' Tee-Let® Welding Branch Outlet Fittings offer the user a high strength, low cost forged threaded and grooved line of fittings spe- cifically designed and manufactured to be installed on Schedules 5 thru 10, proprietary thin wall flow pipe and standard wall pipe. Merit Tee-Lets are forged steel welding outlet fittings. The material used in manufacture meets the chemical and physical requirements of ASTM A 53, Grades A or B, Type E, A-135, A-795, Tee-Lets employ a low weld volume design to provide for either a partial or full penetration weld employing a single pass with minimum burn-through and pipe distortion. Weld Miser Tee-Lets are recommended for use on proprietary thin wall, Schedules 5, 10 and 40 pipe. Threads comply with ANSI B1.20.1 or lSO7/1. They are UL Listed and FM Approved for use conforming to the requirements of Bulletin 13 1999 of the National Fire Protection Association. When used in fire sprinkler systems, Tee-Lets are rated for 300 psi. When used in mechanical systems, maximum pressures are calculated using criteria de- veloped for ASME 631 piping code. APPROVED For listing/approval details contact your AnviISta, Representative. TEE-LET IWELDED iOUTLET ZU — EX6032, FM APPROVAL GUIDE1II1JiU I PIPE iiIlIiet1 Outlet Model Outlet Pipe Size Header Pipe Size Rated Pressure (Inch) (Inch) (psig) 1/2,3/4, 1 1,8 (Sch.10, 40) 1/2 4 (Sch. 5, DynaFlow) Tee-Let Type A 11/4,11/2.2, 2½, 3,4 (F-Threaded End) 300 2 4 (EZ-Flow) 2,4 6 (EZ-Flow) Tee-Let Type C 11/4.8 11/4 .8(Sch.10,40) (Grooved End) 300 1/2.4 (Sch. 5, DynaFlow) . 2½. 5• Tee-Let Type C/R 11/4 .6 11/4.8 (All Schedules) 300 (Roll _Grooved _End) Size-on-size (i.e. 2 x 2) Tee-Lets are not FM Approved. FM rated working pressure when welded on Sch. 5 or non-threadable lightwall pipe is 175 psi. iiMLStar Fire Products Division Type A Female Threa WeIdMiserTM Tee-Let® Welding Outlet Fittings WELD -MISER IlI DIMENSIONS PART 1fl Part Nominal Nominal Outlet Inside Make Weight Number Outlet u er Header Length Diameter Up Each A B C U Ill NPT (BSPT) In (mm) In (mm) In (mm) In (mm) In (mm) Lb. (kg) 1002002 1/4 x 11/4 8 0.080 - 6K 6-200 1 0.04 1005012 11/4 - 11/2 1.063 0.700 0.500 0.171 - 32-40 270 17.8 12.7 0.08 1005015 1½ -2 1.063 0.700 0.500 0.171 X 13 40 -50 27.0 17.8 12.7 0.08 1005020 2- 2½ 1.063 0.700 0.500 0.171 - 50 -65 27.0 17.8 12.7 0.08 1005025 21/2 -8 1.063 0.700 0.500 0.169 - 65-200 27.0 17.8 12.7 0.08 1007012 11/4 11/2 1.125 0.900 0.500 0.260 32-40 28.6 22.9 12.7 0.12 1007015 11h -2 1.125 0.900 0.500 0.260 - 3/4 X 19K 40 -50 28.6 22.9 12.7 0.12 1007020 221/2 1.125 0.900 0.500 0.260 - 50-65 28.6 22.9 1 12.7 0.12 1007025 21h -8 1.125 0.900 0.500 0.256 - 65-200 28.6 22.9 12.7 0.12 1010012 11/4 11/2 1.250 1.145 0.500 0.331 1110012 32-40 31.8 29.1 12.7 0.15 1010015 1½ -2 1.250 1.145 0.500 0.331 1110015 40-50 31.8 29.1 12.7 0.15 1010020 2- 2½ 1.250 1.145 0.500 0.320 1110020 1 x 25x 50-65 31.8 29.1 12.7 0.15 1010025 21/2-3 1.250 1.145 0.500 0.314 1110025 65-80 31.8 29.1 12.7 0.14 1010030 3-4 1.250 1.145 0.500 0.309 1110030 80-100 31.8 29.1 12,7 0.14 1010050 5-8 1.250 1.145 0.500 0.291 125-200 31.8 1 29.1 12.7 1 0.13 1012012 11/4 - 1½ 1.375 1.490 0.500 0.432 1112012 32-40 34.9 378 12.7 .019 1012015 1½ -2 1.375 1.490 0.500 0.421 1112015 40-50 34.9 37.8 12.7 .019 1012020 2- 21A 1.375 1.490 0.500 0.421 1112020 11/4 x 32 x 50 -65 34.9 37.8 12.7 .019 1012025 21A -3 1.375 1.490 0.500 0.411 1112025 65-80 34.9 378 12.7 .019 1012030 3-4 1.375 1.490 0.500 0.389 1112030 80-100 34.9 378 12.7 .018 1012050 5-8 1.375 1.490 0.500 0.389 1112050 125 -200 1 34.9 37.8 12.7 .018 1015015 11/2 1.625 1.610 0.875 0.477 1115015 40 41.3 40.9 22.2 .022 1015020 2 1.625 1.610 0.875 0.477 1115020 ii, x 50 41.3 40.9 22.2 .022 1015025 21/2 1.625 1.610 0.875 0.477 1115025 , 65 41.3 40.9 22.2 .022 1015030 3-4 1.625 1.610 0.875 0.477 1115030 80 -100 41.3 1 40.9 1 22.2 1 .022 1015040 4 1.625 1.610 0.875 0.477 1115040 100 41.3 40.9 22.2 .022 1015050 5-8 1.625 1.610 0.875 0.477 1115050 125-200 41.3 40.9 22.2 .022 WELD -MISER T TEE-LET'DIMENSIONS & PA Part Nominal Nominal Outlet Inside Make Weight Number Outlet ' Header Length Diameter Up Each A B C M NPT (BSPT) In (mm) In (mm) In (mm) In (mm) In (mm) Lb. (kg) 1020020 2 1.750 2.067 0.875 0.857 1120020 50 44.5 52.5 22.2 038 1020025 21/2 1.750 2.067 0.875 0.829 1120025 65 44.5 52.5 22.2 0.38 1020030 3 1.750 2.067 0.875 0.829 1120030 2 x 80 44.5 52.5 22.2 039 1020040 4 ' 1.750 ' 2.067 0.875 0.800 1120040 50x 100 445 52.5 22,2 0.36 1020050 5 1.750 2.067 0.875 0.743 1120050 125 44.5 52.5 22.2 0.34 1020060 6 1.750 2.067 0.875 0.743 1120060 150 44.5 52.5 22.2 0.34 1020080 8 1.750 2.067 0.875 0.743 1120080 1 200 1 44.5 52.5 22.2 1 0.34 1025025 21/2 2.215 2.469 1.125 1.250 1125025 65 54.0 62.7 28.6 0.55 1025030 3 2.215 2.469 1.125 1.200 1125030 80 54.0 62.7 28.6 0.55 1025040 4 2.215 2.469 1.125 1.150 1125040 2½x 65K 100 54.0 62.7 28.6 0.52 1025050 5 2.215 2.469 1.125 1.150 1125050 125 54.0 62.7 28.6 0.52 1025060 6 2.215 2.469 1.125 1.150 1125060 150 54.0 62.7 28.6 0.52 1025080 8 2.215 2.469 1.125 1.150 1125080 200 54.0 62.7 28.6 0.52 1030030 3 2.500 3.068 1.500 1.750 - 80 63.5 77.9 38.1 079 1030040 4 2.500 3.068 1.500 1.700 - 3 x 100 63.5 77.9 38.1 0.77 1030050 5 2.500 3.068 1.500 1.700 - 80K 125 63.5 1 779 38.1 0.77 1030060 6 2.500 3.068 1.500 1.650 - 150 63.5 779 38.1 0.75 1030080 8 2.500 3.068 1.500 1.650 - 200 63.5 77.9 38.1 0.75 1040040 4 3.000 4.026 2.000 3.000 - 100 76.2 102.3 1 50.8 1.36 1040050 5 3.000 4.026 2.000 2.900 - 4x '10x 125 76.2 102.3 50.8 1.32 1040060 6 3.000 4.026 2.000 2.800 - 150 76.2 102.3 50.8 1.27 1040080 8 3.000 4.026 2.000 2.800 - 200 1 76.2 1 102.3 50.8 1.27 Note: Part #1002002 is not UL Listed or FM Approved. All size-on-size (i.e. 2 X 2) Tee-Lets are not FM Approved. iNAi...Star Fire Products Division Type B Male Thread Standard Weight Type C Cut Groove Standard Weight WeIdMiserTM Tee-Let® Welding Outlet Fittings FIT !!lT DIMENSIONS TT Male Thread Cut Nominal Outlet Groove Nominal Header Outlet Length Inside Diameter Outside Diameter Wall Thickness Std Wt A Std. Wt. B C D E F NPT(BSPT) NPT(RSPT) in. (mm) in. (mm) In. (mm) in. (mm) in. (mm) in. (mm) 1310012 2010012 11/4 11/2 3 1.049 1.315 0.133 32-40 80 26.6 33.4 3.4 1310015 2010015 1½-2 3 1.049 1.315 0.133 1 x 40-50 80 26.6 33.4 3.4 1310020 2010020 2 21/2 3 1 049 1-.315'-- 0.133 25x 50-65 80 26.6 - - 33.4 3.4 1310025 2010025 21/2 4 3 1.049 1.315 0.133 65-100 80 266 33.4 3.4 1310050 2010050 5-8 3 1.049 1.315 0.133 125-200 80 26.6 33.4 3.4 1312012 2012012 11/4 3 1.368 1.660 0.140 32 80 347 42.2 3.6 1312015 2012015 1½ 3 1.368 1.660 0.140 11/4 x 40 80 34.7 42.2 3.6 1312020 2012020 2 -21/2 3 1.368 1.660 0.140 32x 50-65 80 34.7 42.2 3.6 1312025 2012025 3-4 3 1.368 1.660 0.140 80-100 80 34.7 42.2 3.6 1312050 2012050 5-8 3 1.368 1.660 0.140 125-200 80 34.7 42.2 3.6 1315015 2015015 1½ 3 1.610 1.900 0.145 40 80 40.9 48.3 3.7 1315020 2015020 2 3 1.610 1.900 0.145 11/2 x 50 80 40.9 48.3 3.7 1315025 2015025 21/2 3 1.610 1.900 0.145 49x 65 80 40.9 48.3 3.7 1315030 2015030 3-4 3 1.610 1.900 0.145 80-100 80 40.9 48.3 3.7 1315050 2015050 5-8 3 1.610 1.900 0.145 125-200 80 40.9 48.3 3.7 1320020 2020020 2 3 2.067 2.375 0.154 50 80 52.5 60.3 3.9 1320025 2020025 21/2 3 2.067 2.375 0.154 65 80 52.5 60.3 3.9 1320030 2020030 3 3 2.067 2.375 0.154 2 x- 80 80 52.5 60.3 3.9 1320035 2020035 4 3 2.067 2.375 0.154 50x 100 80 52.5 60,3 3.9 1320050 2020050 5 3 2.067 2.375 0.154 125 80 52.5 1 60.3 1 3.9 1320060 2020060 6 3 2.067 2.375 0.154 150 80 52.5 60.3 3.9 1320080 2020080 8 3 2.067 2.375 0.154 200 80 1 52.5 60.3 3.9 Note: Tee-Lets are manufactured to fit size-on-size. that is the contoured shane on a oiven Tee-f pJ is made to fit nerfer.tiv on the first listed header 517P If installed on the second header size marked on the fitting, a slight gap of approximately 1/2' will appear along the longitudinal centerline of the header. For example, a lx 2 - 21/2 Tee-Let, is a 1' outlet fitting manufactured to fit perfectly on the 2 header size listed, while leaving a 1,2' gap along the longitudinal centerline of the 21, size. If a perfect fit is required for a 21W header pipe, then aix 21/t -3' Tee-Let would be ordered. Size consolidations are employed to reduce inventory and provide for greater flexibility. IWtLStar Fire Products Division MERIT® WeIdMiserTM Tee-Let® Type B Male Thread Welding Outlet Fittings Standard Weight Type C Cut Groove Standard Weight Type C/R Roll Groove Schedule 10 AI1 !1!DIMENSIONS ( j Cut Nominal Nominal Outlet Inside Diameter - D Outside Wall Thickness - F Mae Thread d Std Std. .Groove R G Sch.1O Outlet Header Length Diameter Standard Schedule Standard Schedule Wt. A B C Weight 10 E Weight 10 NPT (ISO-i-I) NPT (ISO-i-I) I/PT (ISO-i-i) In.(,nm) In.(mm) In.(mni) In.(mm) In.(m;n) In.(,nm) in. (mm) In.(mm) 1325025 2025025 2225025 2½ 3 2.469 2.635 2.875 0.203 0.120 2125025 65 80 62.7 67.0 76.2 5.0 3.0 1325030 2025030 2225030 3 3 2.469 2.635 2.875 0.203 0.120 2125030 . 80 80 62.7 670 76.2 5.0 3.0 1325035 2025035 2225035 4 3 2.469 2.635 2.875 0.203 0.120 2125035 21/2 x 65K 100 80 62.7 870 76.2 5.0 3.0 1325050 2025050 2225050 5 3 2.469 2.635 2.875 0.203 0.120 2125050 125 80 62.7 670 76.2 1 5.0 3.0 1325060 2025060 2225060 6 3 2.469 2.635 2.875 0.203 0.120 2125060 175 80 62.7 870 76.2 5.0 3.0 1325080 2025080 2225080 8 3 2.469 2.635 2.875 0.203 0.120 2125080 200 60 62.7 670 76.2 5.0 3.0 1330030 2030030 2230030 3 3 3.068 3.260 3.500 0.216 0.120 80 80 78.0 83.0 1 880 5.0 3.0 1330035 2030035 2230035 31/2 3 3.068 3.260 3.500 0.216 0.120 . 85 80 78.0 83.0 88.0 5.0 3.0 1330040 2030040 2230040 4 3 3.068 3.260 3.500 0.216 0.120 3x 80K 100 80 78.0 83.0 88.0 5.0 3.0 1330050 2030050 2230050 5 3 3.068 3.260 3.500 0.216 0.120 125 80 78.0 83.0 88.0 1 5.0 3.0 1330060 2030060 2230060 6 3 3.068 3.260 3.500 0.216 0.120 150 80 78.0 83.0 88.0 5.0 3.0 1330080 2030080 2230080 8 3 3.068 3.260 3.500 0.216 0.120 200 80 78.0 83.0 88.0 5.0 3.0 1340040 2040040 2240040 4 4 4.026 4.260 4.500 0.237 0.120 100 100 102.0 108.0 1 114.0 6.0 3.0 1340050 2040050 2240050 5 4 4.026 4.260 4.500 0.237 0.120 4x bOx 125 100 102.0 108.0 114.0 6.0 3.0 1340060 2040060 2240060 6 4 4.026 4.260 4.500 0.237 0.120 ,... 150 100 102.0 108.0 114.0 6.0 3,0 1340080 2040080 2240080 8 4 4.026 4.260 4.500 0.237 0.120 200 1 100 102.0 108.0 114.0 1 6.0 3.0 - 2060060 2260060 6 4 6.065 6.357 6.625 0.280 0.134 6x 150x 150 100 155.0 161.5 168.3 ti 3.0 - 2060080 2260080 . 8 4 6.065 6.357 6.625 0.280 0.134 200 100 155.0 161.5 168.3 71 3.0 - 2080080 - 8 x 8 4 7.981 8.329 8.625 0.322 0.148 200x 1 200 1 100 1 203.0 1 212.0 213.0 1 8.0 1 3.0 Note: Tee-Lets are manufactured to fit size-on-size. that is the contoured shane on a niven Tee-Let is made to fit nerfectiv on the first listed header Si7R If installed on the second header size marked on the fitting, a slight gap of approximately 1/32" will appear along the longitudinal centerline of the header. For example, a lx 2 - 21/2" Tee-Let, is a 1" outlet fitting manufactured to fit perfectly on the 2" header size listed, while leaving a 1/32" gap along the longitudinal centerline of the 21/Y size. If a perfect fit is required for a 21h" header pipe, then a lx 21/2 -3" Tee-Let would be ordered. Size consolidations are employed to reduce inventory and provide for greater flexibility. -6- iN7Star Fire Products Division Threading Practice Weld-Miser TM Tee-Let® Installation Welding Outlet Fittings &,,tToo4.ot POd, Un leaving : fully fonoedfemale th-d. V MERIT NPT THREAD FORM Fon,oje TILITt Malo Ppo ST.Ie~ dn i Mmealicm on STANDARD NPT THREAD FORM NPTSTAPERED PIPE TH iii Drop Nipple Li 13 Total 12 or Tee-Let Hand Tight Wrench Tig ht Li - 13 Effective Outlet Size Lenoth Threads In. (mm) In. (mm) Threads jjyg) Thread'Threads .(ml Threads 1&" 0320 4.48 3.00 0.534 7.48 7.47 15 81 -ia-- 136 3/4" _ 0.339 4.75 7.75 20 86 54 14.0 _ 0,400 4.60 0.261 3.00 0.661 7.60 0.683 78,5 25 102 6.6 16.8 11/4 0.42F 4.83 0.261 3.00 0.681 7.83 0.707 813 32 10/ 6.6 173 1½" _ 0420 61 0.697 7.83 0.724 8 40 107 JL _ 18.4 _ 601 0.706 8.01 8J0 50 111 6.6 17.9 21h" 0.682 5.46 0.250 2.00 0.932 7.46 1.138 9.10 65 17.3 6.4 23.7 3 0.766 6.13 0.250 2 1.016 8.13 1.200 9.60 80 195 6.4 25.8 4 _ 8.75 300 10 100 214 6.4 27.8 Domestic Manufacture Increasingly, federal, state, municipal, and quasi municipal authorities require domestic content for fire sprinkler systems. Merit® Tee-Lets® meet these requirements. The need to maintain dual inventories; one domestic; one import is eliminated. Welding Practice Tee-Let® thread form is consistent with Aeronautical National Form (ANPT) AS71051. The thread is fully formed over both the L-1 hand tight and L-3 wrench tight threads. NPT tapered threads are typically gauged only over the L-1 threads. This makes Tee-Lets more forgiv- ing of field cut threaded pipe that may only marginally conform to the specification. Fewer leaks translate into lower costs. Ease of Installation Merit Manufacturing Tee-Lets are designed to sit higher on the pipe, thereby requiring less weld and eliminating burn through. Tee-Lets sit higher on the header or branch line pipe than competitive fittings. This allows the welding torch to remain in an optimum position for welding. In addition, 11&" and larger Type A female threaded and Type C grooved Tee-Lets require the same hole size for installation. This re- sults in fewer change overs when installed using automatic welders. When measured with respect to linear inches of weld required for installation, Tee-Lets require up to 15% less weld than competitive fittings. This reduces time and savings over time are substantial. The diameter of the contoured end of Type A Tee-Lets has been reduced so that the wall thickness more nearly matches the header or branch line pipe wall thickness. Therefore, current and voltage settings required for welding are set to provide for adequate penetration without burn through and cold shutting. Also, weld volume required for installation is lower for Tee-Lets than most other fittings. Typically, Tee-Lets re- quire one-weld pass for attachment. 2.650" - 2820' - - .205-I I.- 2" Merit Weld-Miser Tee-Let 2" Competitive Fitting WELDING PRACTICE Outlet I MERIT WELD-MISER TEE-LET I COMPETITIVE FITTING Size WELD VOLUME* LINEAR WELDING WELD VOLUME* LINEAR WELDING In. (mm) Cross Sec. Area %Iess In. (mm) %Iess Cross Sec. Area %more In. (mm) %!oss 0.051 sq. in. 2.48 0.058 sq. in. 2.48 12% 0% 12% 0% 25 32.9 sq mm 62.9 37.4 sq mm 62.9 11/4" 0.032" 2.88 0.063 3. 01 48% 4% 48% 4% 32 20,6 73.1 40.6 76.4 1½' 0.036" 3.12 0.060 3.46 40% 1O% 40% . bob 40 23.2 1 79.2 1 38.7 1 87.8 0.040" 3.77 0.106 4.41 62% 15% 62% 15% 50 25.8 95.7 683 112.0 Iiñ7LStar -7- Fire Products Division RECOMMENDED TEE-LET HOLE SIZES Tee-Let Size Type Recommended Hole Size In./mm In./mm 1/2 Type ¼ 13 16 34 Type /8 19 22 1 Type 11/a 25 28 11/4 Type 11/2 31 38 11/4 Type 1/4 31 35 11/2 Type AorC 1/4 38 41 2 Type AorC 2 50 50 2¼ Type AorC 27/i& 63 61 3 Type AorC 3 75 75 4 Type AorC 4 100 100 Holes may be cut employing mechanical means--including hole sawing, mechanical flathe cutting (oxy-acetylene or propane), and air plasma cutting (constricted tungsten arc) machines. Merit offers a simple approach to cut- ting the hole. Hand-held templates are sized to match your plasma cutter. / MERIT® WeIdMiserTM Tee-Let® Installation (cont.) Welding Outlet Fittings Recommended Installation Procedures Merit Weld-Miser Tee-Let Welding Outlet Fittings are designed and manufactured to reduce the cost of installa- tion from both the standpoint of labor required and energy consumed. In addition, by following the recommended in- stallation procedures, many of the problems associated with installing welding outlet fittings on standard weight or light weight pipe are eliminated, including burn through and excessive shrinkage resulting in pipe distortion. Recommended Hole Sizes The hole cut in the branch or header pipe can be cut prior or sub- sequent to attachment of the Tee-Let. One advantage of cutting the hole after welding is that the pipe is left intact during welding thereby reducing shrinkage and possible distortion. If holes are cut prior to welding, as some codes require, then the following hole sizes are recommended.-Note that the same hole diameter fora given outlet size is required for both Type A and Type C Tee-Lets 1-11/2" larger. Recommended Welding Procedures Merit Weld-Wiser Tee-Lets are designed to be installed on standard weight or light weight pipe with one weld pass on Type A outlet sizes from 1/20 through 21/2 inclu- sive, and on Type C outlet sizes through 4'. Moreover, the wall thickness at the weld end of the fitting approximately matches standard weight pipe. Accordingly, heat setting can be made to optimize penetration on both the fitting and the pipe which it is being welded. Aside from reducing the likelihood of burn through and distortion resulting from excessive heat, the amount of weld required for adequate penetration is significantly reduced. Merit Tee-Lets are manufactured from continuous cast aluminum killed steel with a carbon range of from 0.05 to 0.25. Merit specifies that residuals, such as chrome, nickel and other metals resident in the scrap used for production of the steel be reported and kept to a minimum. On the other hand, certain grades of carbon steel pipe are manufactured from skelp whose chemical composition is not speci- fied. When the metal inert gas shield (MIG) welding process is employed, certain residuals may cause excessive porosity, spatter or lack of penetration. Specifically, gases released during the welding process do not escape before the molten puddle sets up. When porosity or lack of penetration occurs, one approach is to slightly increase the heat in order to give the gases time to escape from the puddle. A flux cored wire can also be used. This wire contains scavengers which allow gases in the molten weld puddle to escape before the weld solidifies.The following recom- mended settings for welding therefore may need to be adjusted slightly higher if any of the above mentioned adverse conditions exist. As a general rule, the weld should be only as hot as required to allow the weld to penetrate the materials being welded while concomitantly allowing gases developed in the welding process to escape. Every effort must be made to avoid welding too hot or overheating both the pipe and the Tee-Let. Excessive heat may cause the wrench tight threads (those in the bottom of the Tee-Let near the weld zone) to distort while also causing the branch pipe to bend. It should be noted that Merit Tee-Lets have been subjected to exhaustive testing and evaluation, and only negli- gibly distort when subjected to excessive heat. The threads, on the other hand, may not return to their gauged form after cooling if excessive heat causes them to expand. The following is intended only as a guide, and assumes that the welding equipment is properly calibrated and functioning normally and the operator is qualified. —8- RECOMMENDEDTTIIIII OF "iiu' Outlet A B Size In/mm In/mm In.fmm 1/4 1/4 13 7 5 3/4 1/4 3A6 19 7 5 1 1/4 3Aa 25 7 5 1¼ i/4 3Aa 31 7 5 1½ 5Aa 1/4 38 8 7 2 5A6 1/4 50 8 7 2¼ 5Aa ¼ 63 8 7 3 /a /16 75 10 5 4 %. •. /I6 100 10 . 5 IMiLStar Fire Products Division 1/2, 3/4 & 1 Outlet 11/4 21/2 Outlet TO WeldMiserTM Tee-Let® Installation (cont.) Welding Outlet Fittings RECOMMENDED SETTINGS FOR MICROWIRE WELDING PROCESS, CONTINUED ON NEXT PAGE Header Size Pipe Wall Thickness Tee-Let Types A, B, C Electrode Size Welding Current Arc. Volts Wire Feed Travel Speed In/mm In/mm In/mm AMPS-DC POS. IPM IPM 1/2 2 0.035 100-130 16-20 210 25-30 0.065 13-50 2 21/2 4 0.035 115-150 17-21 270 20-25 1Y4-2 63-100 31-50 1,4.2 0.035 110-140 18-22 220 25-30 0.109 13-50 21,4.4 0.035 120-160 19-22 290 20-25 3 63-100 1,4 0.035 110-140 17-20 210 20-25 0.083 13-50 2½-4 0.035 120-150 17-20 270 20-25 2.5 21/2 .4 63-100 1/2 2 0.035 120160 1922 290 2025 63100 0.120 13-50 21/2 .4 0.035 130-160 19-22 240 20-25 3 63-100 1/2 .2 0.035 120-150 17-20 210 20-25 0.109 13-50 3 21/t .4 0.035 130-150 18-20 270 15-20 63-100 5-6 1/2 2 0.035 130-160 19-22 290 20-25 125-150 13-50 0.134 24-4 0.035 140-160 20-22 270 15-20 35 63-100 2,4.4 0.045 180-205 20-24 245 27-32 63-100 1,42 0.035 120-150 17-20 240 20-25 13-50 0.109 21/2.4 0.035 130-150 18-20 260 15-20 3 63-100 -4 0.045 170-220 18-22 290 12-18 8 63-100 I/2 0.035 130-160 19-22 240 20-25 200 13-50 0.148 244-4 0.035 140-160 20-22 260 15-20 3.5 63-100 21/2 .4 0.045 180-225 20-24 290 12-18 63-100 1 Shielding Gas Flow (FOR ALL sizes) 20-25 CFH Co2 - Deeper penetration, faster welding, low cost. 25% - Argon, 75% - CO2, Recommended for .134 wall and lighter, high welding speeds without melt through, minimum distortion and spatter, good penetration. Merit assumes no liability for any consequential damages resulting from the improper use of its Tee-Let Welding Outlet Fittings, nor for any recommendations made with respect to installation procedures. INik.Star Fire Products Division —9— 'VJ ANVI L INTERNATIONAL, INC. Corporate Offices 110 Corporate Drive, Suite 10 • P.O. Box 3180 Portsmouth, NH 03802-3180 Tel: 603-422-8000 • Fax: 603-422-8033 E-mail address - Webmaster@anvilintl.com www.anvilintl.com For Sales and Service Information Contact the Regional Service Center Nearest You oi Visit Our Website at www.anvilstar.com U.S. Regional Service Centers NORTHEAST REGION Servicing: Connecticut, Delaware, Maine, Maryland, Massachusetts, New Hampshire, New Jersey, New York, East Pennsylvania, Rhode Island, Vermont, Virginia 2530 Pearl Buck Road Bristol, PA 19007 Tel: 215-788-4056 • Fax: 215-788-4475 Toll Free: 1-800-451-2935 MIDWEST REGION Servicing: Illinois, Indiana, Iowa, Kansas, Kentucky, Michigan, Minnesota, Missouri, Nebraska, North and South Dakota, Ohio, West Pennsylvania, West Virginia, Wisconsin 750 Central Avenue University Park, IL 60466 Tel: 708-534-1414 • Fax: 708-534-5441 Toll Free: 1-800-301-2701 SOUTHERN REGION Servicing: Alabama, Arkansas, Colorado, Florida, Georgia, Louisiana, Mississippi, New Mexico, North and South Carolina, Oklahoma, Tennessee, Texas, Wyoming 1313 Avenue R Grand Prairie, TX 75050 Tel: 972-343-9206 • Fax: 972-641-8946 Toll Free: 1-800-451-4414 WESTERN REGION Servicing: Alaska, Arizona, California, Hawaii Idaho, Montana, Nevada; Oregon, Utah, Washington 1385 Greg Street Sparks, NV 89431 Tel: 775-331-7029 • Fax: 775-331-5075 Toll Free: 1-800-572-0051 EUROPE & MIDDLE EAST REGION Rick van Meesen, Business Director the Netherlands Tel: +31 53 5725570 Fax: +31 53 5725579 U.S. Customer Service Tel: +1 708 534 1414 LATIN AMERICA, PUERTO RICO & MEXICO Art Gutierrez, Sales Manager Tel: 813-300-3721 U.S. Customer Service Tel: 708-534-1414 • Fax: 708-534-5441 IiN_ /iLSt a rT Fire Products Division of AnviI International ANVILSTAR CUSTOMER SERVICE CENTER Tel: 708-534-1414 • Fax: 708-534-5441 Toll Free: 1-800-301-2701 #327 / Printed in USN RPI / 2.5M / 405 / ©2005 Anvil International, Inc. - ____•__% 1• jfr' .• ';. • Wig I-. .,., fl f. 1 ••) - .- v ••, /\ . . • 1 __ ____ 1; jj luctile Iron Threaded Fittinc 14 p 4 .v1 - .' • 2,. 1.. .. 1...• '-• '..' -- ig• • -.. • r H Ductile Iron Threaded Fittings Spedficatioñi_________________________________ branded fittings are UL Listed and FM Approved at 500 psi Rated to 300 psi WSP Ductile iron castings conform to ASTM A536 Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 All fittings are 100% air tested cY/us LISTED APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab verification that fittings meet applicable chemical & mechanical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 ProPakTM Packaging Temperature Degrees F Working Pressure, Non-Shock psig Class 300 Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 r - 1; r I / SCI ProPak System ---- -.-..-.-- - -- -- - -.-- c®US <ze> APPROVED LISTED Fig. 35E 3-90° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 35E3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in Packing Weight lb Inner Master 3/4x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 - 1.53 35 70 0.5 1-1/4x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4x1 35RE3012010 1.58 - 1.67 30 60 0.7 1-1/2x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2x1-114 35RE3014012 1.82 1.88 18 36 1.0 2x1/2 35RE3020004 1.60 1.97 18 36 1.0 2x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2x1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 1 35RE3024020 2.39 2.60 6 12 2.5 A Size in Part Number A in Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 - 0.98 80 160 0.3 1 35F3010 1.13 40 80 0.5 1-1/4 35F3012 1.29 25 - 50 01 1-1/2 35F3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F3024 1 1.95 4 8 2.7 Fig. 35F 3-45° Elbow Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 35T3004 1.13 80 160 0.3 3/4 35T3006 1.31 30 60 0.5 1 35T3010 1.50 25 50 0.7 1-1/4 3513012 1.75 10 20 1 1.1 1-1/2 3513014 1.94 10 20 1 1.5 2 3513020 2.25 6 12 2.4 - 2-1/2 35T 3024 2.70 4 8 1 4.3 237 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wwwsmithcooper.com C®uS Fig. 35RT3 - Reducing Tee LISTED APPROVED Size in Part Number A in - B in - C in Packing Weight lb Inner Master 3/4x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 ix 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1 x 1/2x 1 35R13010004010 1.50 1.36 1.50 30 60 0.6 1x3/4 35R73010006 1.38 1.38 1.45 25 50 0.6 1x3/4x3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1x3/4x1 35R13010006010 751.45 1.50 25 50 C7- 1-1/4 x 1/2 35R13012004 1.34 1.34 1.53 20 40 0.8 1-1/4x1/2x1-1/4 35RT3012004012 115 1.53 1.75 25 50 0.9 i-1/4 x3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4x3/4x1-1/4 35R13012006012 115 1.62 1.75 20 40 1.0 1-1/4x1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4x1x1/2 35R13012010004 1.34 1.26 1.53 25 50 0.7 1-1/4x1x3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4x1x1 35RT3012010010 18 1.50 1.69 20 40 0.9 1-1/4x1x1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2x1/2 35RT3014004 7.41 1.41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x1/2x1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2x3/4x1-1/4 35R13014006012 1.94 1.66 1.88 20 40 1.1 i-1/2x3/4x1-1/2 35R13014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 35RT3014010 1.65 1.65 1.80 12 24 40 1.2 1-1/2x1x1/2 35R13014010004 1.44 1.25 1.69 20 0.8 1-1/2x1x3/4 35R13014010006 1.50 1.75 16 32 0.9 . 1-1/2x lxi 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x1x1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2x1x1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x1-i/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2x1-1/4x1/2 35R13014012004 1.41 1.34 1.66 16 32 0.9 1-1/2x1-1/4x3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2x1-1/4x1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-1/4 35R13014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2x1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2x3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2x1 35RT3020010 1.73 1.73 2.02 2.25 8 16 1.7 2x1x2 35RT3020010020 2.25 2.02 8 16 1.9 2x1-i/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2x1-1/4x2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2x1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35R13020014004 1.49 1.41 1.88 10 20 1.3 2x1-1/2x3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-1/4 35R13020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 35R13020014014 2.02 1.94 1 2.16 1 8 16 1.8 Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in - Packing Weight lb Inner Master 3/4 x 1 35B13006010 1.45 1.45 1.37 30 60 0.6 1x1-1/435BT3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4x1x1-1/2 35BT3012010014: 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4x2 35B13012020 2.10 2.10 1.90 10 20 1.6 i-1/2x1-1/4 x2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2x2 35B13014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 9 www.smithcooper.com 238 Fig. 35CP3 - Straight Coupling with Ribs COU, <~> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 350P3004 138 200 400 0.1 4 35CP3006 1.63 100 200 0.2 1 350P3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 - 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 ~_,8 1.2 2-1/2 35CP3024 3.00 9 2.2 Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb Inner Master 1x1/2 35RC3010004 1.69 80 160 0.3 1x3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (riot hex) I 35R03020010 1 2.81 1 20 40 1 1.0 Fig. 35HB3 -Hex Bushing Size in Part Number A in B in Packing Weight lb Inner Master 1 x 1/2 35HB3010004 1.06 1.40 180 360 0.2 1x3/4 35H33010006 1.06 1.40 180 360 0.1 1-1/4 x1 35HB3012010 1.19 1.80 90 180 0.2 ±112x1 35HB3014010 1.25 1.95 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 125 1.95 75 150 0.3 2 x 1 35HB3020010 1.38 2.55 40 80 0.6 2x 1-1/4 35HB3020012 1.38 2.55 40 80 0.6 2x1-1/2 35HB3020014 1.38 2.55 40 80 0.6 Fig. 355P3 - Square Head Plug I Size in Part Number A in Packing Weight lb Inner Master I 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 I 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 1 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 11111 r57/J Fig. 35113- Union with Brass Seat Size in Part Number _______________ A in Packing Weight lb Inner Master 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 1 6 12 1 2.4 239 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com IC L us <~> APPROVED Fig. 35X 3- Cross LISTED Size in Part Number A in Packing Weight lb Inner Master 1 35X3010 1.50 20 40 0.9 1-1/4 35X3012 1.75 12 24 1.4 1-1/2 35X3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 ILI Fig. 35R13 - Reducing Cross I Size I in I I Part Number I I A I in I B I I in I Packing I Weight I I I I lb I Inner I Master I 1-1/4 x1 I 35RX3012010 I 1.67 I 1.58 I 15 30 I 1.2 I I1-1/2x1 I 35RX3014010 1.80 I 1.65 12 I 24 I 1.4 I 2x 1 35RX3020010 I 2.02 I 1.73 1 8 16 I 2.0 INS. An, mum ONE Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 3503010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 1 70 140 0.4 1-1/2 3503014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 ROOM is =,I=, Fig. 35BC3 - Beam Clamp i I Size in I Part Number i I A I i in I Packing I Weight I lb I i Inner I Master 3/8 I 35B03003 I 0.75 I 100 I 200 0.3 I I 1/2 I 35B03004 0.75 I 80 160 I 0.5 I SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wwsmithcooper.com 240 A c®t us<g Overall Height LISTED APPROVED B Center of pipe to top of knurled hanger rod nut. Top of pipe to bottom of hanger rod nut Fig. 200-'/2 & 200-/4 Fig. 200-1 to 200-2 Pipe Hangers FOLCOFig 200- Trimhne Adjustable Band Hanger TOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing TOLCOTM Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated TOLCOTM Fig. 200S - "Trimline" Adjustable Band Hanger with Removable Nut (For sizes 1" thru 2") Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: 1/2" (15mm) thru 2" (50mm) sizes have flared edges for ease of installation on all pipe types and protects CPVC plastic pipe from abrasion. Captured knurled nut design (flared top) on 1" thru 2" sizes keep nut from separating with hanger. Hanger is easily installed around pipe. 1/2" (15mm), 3/4" (20mm), and 21/2" 165mm) thru 8' (200mm)) Spring tension on nut holds it securely in hanger before installation. Knurled nut is easily removed. For 1/2" (15mm) and 3/4" (20mm) sizes with non-captured knurl nuts order Fig. 200S Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-I 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F 1343°C) L I Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Part number and pipe size ** Note: For metric hanger rod sizes add the metric rod size to the figure number. Example: 200M8-1 1/2 or 200M 101h/2 Fig. 200C Fig. 200F Fig. 200 Fig. 200 & Fig. 200S t M8 rod size is not UL Listed or FM Approved 200C-11/2 shown 200E-11/2 shown shown with captured nut shown with 1" thru 2" sizes only non-captured nut Pipe Size Rod Size A B D Max. Rec. Load Approx. Wt./100 Part No.** in. (mm) in. mm* in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 200_1/2 1/2" (15) /8"-16 M8t or M10 31/8' (79.4) 2/8 (66.7) 111/32" (34.1) 400 (1.78) 11 (5.0) 200-/4 3/4" (20) /8"-16 M8t or M10 31/8" (79.4) 21/2" (63.5) 11/16" (27.0) 400 (1.78) 11 (5.0) 200-1 1 (25) 3/8"-16 M8t or M10 33/8 (857) 2/8 (667) 11/8 (286) 400 (178) 12 (55) 200-11/4 11/4' (32) /8"-16 M8t or M10 33/4" (94.0) 2/8" (73.0) 1/32" (29.3) 400 (1.78) 13 (5.9) 200-11/2 11/2 (40) 3/8"-16 Mt8orM10 37/8 (984) 2/8 (730) 1/16 (302) 400 (178) 14 (64) 200-2 2' (50) /t"-16 M8t or M10 41/2" (114.3) 3" (76.3) 1/16" (30.2) 400 (1.78) 15 (6.9) 20021/2 21/2 11 (65) 3-/8"-16 MIO 55/8 (1429) 41/8 (1047) 1/16 (365) 600 (267) 27 (123) 200-3 3" (75) /8'-16 M10 57/8" (149.1) 4" (101.6) 11/4' (31.7) 600 (2.67) 29 (13.3) 200-31/2 31/2 (90) /8 16 M10 73/8 (1873) 51/4 (1333) 2Il6 (556) 600 (261) 34 (156) 200-4 4" (100) /8"-16 MiD 7 /8" (187.3) 5" (127.0) 1/8" (34.9) 1000 (4.45) 35 (16.0) 2005 5 (125) 1/2 13 M12 91/8 (2318) 61/4 (1587) 311/32 (849) 1250 (556) 66 (302) 200-6 6" (150) 1/2"13 M12 101/8" (257.2) 6/4" (171.4) 2/32" (56.3) 1250 (5.56) 13 (33.4) 200-8 8" (200) '/2-13 M12 131/8" (333.4) 8/4" (222.2) 3/32" (81.7) 1250 (5.56) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 23 Eaton Function: Used as..pacer at a seismic brace location to keep clevis hanger fro ollapsing during seismic event. Approvals: Included in our mic Engineering Guidelines approved by the State of Californi ffice of Statewide Health Planning and Development (OSHPD . or additional load, spacing and placement information relating to 0 D projects, please refer to our Seismic Engineering Guidelines OPM- 2-13, for 2½" -8" (B3100) only Installation Note: Fig. 1CBS fits easily over the cross It and attaches by pinching tabs down. Finish: Pre-Galvanized. Contact customer service for alternative finishes and materials. Order By: Figure number and finish Sizes 1', (25) thru 11/2 (40) TQLCOTM Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4 (20mm) thru 2' (40mm) pipe Material: - Pre-Galvanized Steel 1CBS-18 18" (450) 224.6 (101.9) 1CBS-20 20" (500) 4.0 (115.2) ki Pipe Hangers Fig. 1CBS - Clevis Bolt Spacer Size R e: Size 1" (25mm) thru 20 )500mm) clevis hanger Material: St Pipe Size Approx. Wt./100 Part No. in. -. 1" (mm) lbs. (kg) 1CBS-1 3.2 (1.4) 1CBS-11/4 11/4" (32) 4.1 (1.8) 1CB's 11I2 11/2 (40) 48 (22) 1CBS-2 (50) 9.4 (4.2) 1CBS 21/2 21/2 (65) 114 (52) 1CBS-3 (75) 13.9 (6.8) L 1CBS-3'/2 31/2" (90) 16.0 (7.2) 1CBS-4 (100) 18.0 (8.1) 1CBS 5 5 (125) 213 (124) S-6 6" (1501 32.5 (14.7) 1CBS 8 (200) 425 (192) 1CBS-10 10" (250) 72.7 (32.9) 1CBS-12 " (300) 863- (39.1) 1CBS-14 14" 501 157.6 (71.5) 1CBS-16 16" (400) 183.1 (83.3) Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2016 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4' (20mm) thru 2' (40mm). Patent #5,344,108 Approx. Wt/100 Part No. lbs. (kg) 25 4.8 (2.2) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton Revised 8/8/2014 22 B-Line series Fire Protection Solutions Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) B3205L - Threaded Rod (right & left hand threads) Size Range: I8"-16 thru /°-9 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Order By: Figure number, rod size, length and finish TI Specify Length TL ~read 0000 0000 00 Standard Design Load Thread Size Thread length TI 650°F (343°C) 150°F (399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x I /8"-16 21/2" (63.5) 730 (3.25) 512 (2.54) B3205-1I2 x 1' 1/2"13 21/2" (63.5) 1350 (6.00) 1057 (4.70) 83205-5/8 x I' 5/8"_11 21/2 (635) 2160 (961) 1692 (752) B3205-3/4 x 1 /4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/s x 7/8 9 31/2" (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog AIR - All Threaded Rod - 120" (3.05m) Lengths TOLCOTM Fig. 99 - All Threaded Rod Cut To Length Size Range: 1/4"..20 thru /8"-9 rod in 120" lengths or cut to length Material: Steel Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Ga Ivan ized. Contact customer service for alternative finishes and materials. Approvals: Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. Order By: Figure number, rod size, length and finish OPM Eaton Part No. - Size x length Threads Recommended load Approx. Wt./100 Ft. ATR Fig. 99 Per Inch Lbs. (kN) Lbs. (kg) ATR 'IC x 120 99-1/4" x length 20 240 (1.07) 12 (544) ATR 3/8° x 120 99-/8" x length 16 730 (3.24) 29 (13.15) ATR 1/2" x120 99-1/2" xlength 13 1350 (600) 53 (2404) ATR 5/8" x120 995/8" x length 11 2160 (9.60) 89 (40.37) ATR 3/4" x120 993/4 xlength 10 3230 (1437) 123 (5579) ATR hg" x 120 991/8" x length 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. Al) dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 96 B-Line series Fire Protection Solutions 0 M 6d do If / / 1 ':-- •• ! H. JJ cing F:::::I Branch Line Restraint System Traditional methods for installing branch line restraints in fire sprinkler systems are cumbersome and time-consuming. Contractors often cut (and re-cut) threaded rod to precise measurements to restrain the sprinkler pipe with a loop hanger and surge restraint. Traditional methods also commonly require five or more parts per restraint. To avoid these labor-intensive methods, ERICO has streamlined the process and developed the Branch Line Restraint System, part of the CADDY' line of hanging and bracing solutions for the fire protection market. Ideal for restraining 1" (25 mm) through 2" (50 mm) branch lines, this innovative system is significantly faster and easier to install than current methods. It attaches directly to steel bar joists, I-beams or purlins, as well as concrete and wood structures. The hardware is installed with only one tool, a 5/16" (8 mm) socket drill driver, which provides significant labor savings and convenience. It features a simple, two-step installation process, allowing a time savings of up to 80% compared to other methods. Unlike most solutions that only accept 3/8" (M10) threaded rod, the versatile Branch Line Restraint System features a swivel attachment that can be rotated to accept 3/8" or 112" (M10 or M12) threaded rod. This allows greater restraint distances from the pipe to structure with 1/2" (M12) threaded rod. The system meets the requirements of NFPM 13, making it ideal for new construction applications. The total system is cULus' Listed and FM Approved, and has been pre-approved by the state of California (OSHPD OPA-2629-10). 'L1 4 Al :11. I Features Accepts 3/8" or 1/2" (M 10 or M12) threaded rod Quick grip clamp simplifies measuring and cutting of threaded rod Works with rough-cut threaded rod and eliminates pipe-side deburring Can be installed with threaded rod above or below the service pipe Shear-off head helps ensure correct torque and simplifies inspection h1 __ ik. - 00 y _r_T Specifications Material: Steel Finish: Electro-galvanized ? c®us Part Number CSBBRP0100EG Pipe Size Outer Diameter 1" 1.32' Rod Size 3/8", 1/2" Height 6.67" Length 1.63" Width 0.88" CSBBRP0125EG 1 1/4" 1.66" 3/8", 1/2" 7.56 1.97" 0.88" CSBBRP0150EG 11/2" 1.90" 3/8", 1/2" 820" 2.21" 0.88" CSBBRP0200EG 2" 2.38" 3/8", 1/2" 9.45" 2.69" 0,88" 94 www.erico.com Features Swivel connector accepts 3/8" or 1/2" (M10 or M12) threaded rod Attaches to concrete anchors or strUctural attachments with female threads IRS Specifications Material: Steel Finish: Electrb-galvanized C®us Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. www.erico.com 97 ERICO c®Us LISTED APPROVED Upper Attachments TOLCOTh Fig. 58 - Threaded Side Beam Bracket Size Range: /8'-16 rod, pipe sizes 1/2" (15mm) thru 4(100mm) Material: Pre-Galvanized Steel Function: Practical and economical bracket used to support piping from wood, concrete or steel beams. Features: Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept /8" and 1/2" fastener bolts. Per NFPA 13: 1/2" (15mm) thru 2 (50mm) pipe requires /8" fastener, 21/2" (65mm) thru 4" (100mm) pipe requires 1/2" fastener.* Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved thru 4' (100mm) pipe. Finish: Pre-Galvanized Order By: Figure number and finish *Note: Additionally UL has listed the Fig. 58 with fasteners as shown in table below 2- 1/4 x 2' Lag Bolts (No Pre-Drilling Up to 4" (100mm) pipe Per NFPA 1-3/e'0r1/2'Lag Bolts Up to 4" (100mm) pipe 2-#16x 2' Drive Screws /2 (15mm) - 4" (100mm) pipe Ti 10) IC. IC. UL Listed Fastener Table Pipe Size Qty Fastener Type Material 2" 2 #16 x 2' Drive screws Wood - 2" 1 /8' Lag bolt Wood 21/2" - 4' 1 1/2" Lag bolt Wood - 31/2" 2 1/4' X 11/2' Lag bolts Wood 2 1/4" x 2" Lag bolts ** Wood 4" 2 1/4' xl' Tek screws Metal (15 gauge) 4 2 1/4' xl" Tek screws Metal (16 gauge) ** No pre-drilling Larger pipe sizes can be hung with reduced spacing 2- #14x 1', Tek Type Screws Into Mm. 16 Gauge Steel Up to 4" (100mm) pipe Bolt & Hex Nut Up to 4" (100mm) pipe Part No. Pipe Size Rod A B C Approx. Wt./100 in. (mm) Size in. (mm) in. (mm) in. (mm) Lbs. (kg) 58 1/2" -4" (15- 100) /8"-16 2/4" (69.8) 11/2" (38.1) 11/8" (28.6) 14 (6.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 91 Eaton GENERAL INFORMATION GENERAL INFORMATION SUSPENDER® Rod Hanging Anchors Suspender threaded rod anchors are a next step in the evolution of threaded rod anchoring. These one-piece anchors feature heads that are both end-tapped and cross-tapped to permit both in-line mounting and side-mounting of threaded rod systems, eye rings and more. Suspender anchors feature a universal driver for all anchor sizes. Only the Suspender drive socket is needed with the self-drilling anchors for wood and steel, or in pre-drilled applications. This unique system allows users to consolidate inventory to complete a project and reduces downtime required to retrieve the correct part. DEWALT ANCHORS & FASTENERS SECTION CONTENTS General Information........... Material Specifications..... Installation Specifications Performance Data.............. Ordering Information......... STEEL SUSPENDER 11 7-i I ~' ~_ ~ ~' -. - ~ ~~ WOOD SUSPENDER Hanging Pipe and Sprinkler Systems • HVAC Ductwork and Strut Channels Suspending Conduit and Cable Trays • Suspended Ceilings Lighting Systems and Overhead Utilities • Electrical Systems CONCRETE SUSPENDER FEATURES AN ' BENEFITi + Ease and speed in overhead installation ANCHOR MATERIALS Zinc Plated Carbon Steel ANCHOR SIZE RANGE (TYR) 3/8" for Steel 3/8" for Wood 3/8" for Concrete (Threaded Coupler Heads) APPROVALS l'I!l.i il[. THREAD VERSION + Lower in-place cost, when compared to beam clamps, lag bolts and dropins + Solid, one-piece, cold formed and machined anchor + Coupler head is both end and cross drilled to accept vertical (in-line) and horizontal (side-mount) applications + Entire system requires only one driver + 3/8" to 1/2' thread adapter allows installation of 1/2-13 threaded rod components FM Approvals (FM) - see listing for applicable sizes and types Pipe Hangers components for automatic sprinkler systems Underwriters Laboratory (UL) - see listing for applicable sizes and types Pipe Hangers - File No. EX1289 and VFX17.EX1289 CSI Divisions: 03 16 00 - Concrete Anchors, 05 05 23 - Metal Fastenings and 06 05 23 - Wood, Plastic, and Composite Fastenings. Rod Hangers shall be Suspender anchors as supplied by DEWALT, Towson, MD. Anchors shall be installed in accordance with published instruction and the Authority Having Jurisdiction. Unified Coarse Thread (UNC) SUITABLE BASE MATERIALS Steel Purlins and Beams Wood and Timber Concrete Members I www.DEWALTcom ANCHORS & FASTENERS MATERIAL SPECIFICATIONS MATERIAL SPECIFICATIONS Component Component Mateilal Screw Body Case hardened carbon steel Coupling (UNC thread) Case hardened carbon steel Zinc Plating ASTM B633, SC1, Type Ill (Fe/Zn5) 5' INSTALLATION SPECIFICATIONS Steel Susnender Rod Coupler Size 3/8" Coupling Thread Size (UNC) 3/8-16 Coupling Thread Depth (in.) 3/8 Coupling Height (in.) 1 Socket Driver Size (in.) 1/2 [NNo71e:1 ) h, side mount couplings have full thread depth h head). Installation Guidelines 1. If pre-drilling is required (certain types of wood truss/wood joist and all concrete base materials), select the recommended drill bit type and diameter For concrete, drill a hole to the appropriate embedment depth, adding at least 1/4 to the drilling depth to prevent the tip of the fastener from running into the back of the anchor hole during installation. Wood Susoender Rod Coupler Size 3/8" Coupling Thread Size (UNC) 3/8-16 Coupling Thread Depth (in.) 3/8 Coupling Height (in.) 1 Socket Driver Size (n.) 1/2 Note: the side mount couplings have full thread depth (through head). 2. Select the appropriate socket driver for the anchor size and type to be installed and mount into chuck of installation tool. Insert the coupling head into the socket driver, and install perpendicular to the base material surface. Drive the fastener with a smooth steady motion until the driver and coupling is seated against the surface of the base material. Concrete Susnender Rod Coupler Size 3/8" ANSI Drill Bit (in.) 1/4 Overall Screw Shank Length 2-1/4 Anchor Thread Length (in.) 2 Coupling Thread Size(UNC) 3/8-16 Coupling Thread Depth (in.) 1/2 Coupling Height (in.) 1 Socket Driver Size (in.) 1/2 Note: the side mount couplings have full thread depth (through head). 3. Thread the appropriate diameter steel threaded rod or threaded bolt into the coupling. The threaded rod or bolt should fully engage the thread length of the coupling on a vertical mount fastener. The threaded rod or threaded portion of the bolt can pass through coupling of a side mount attachment. When installing Suspender, eye protection should be worn as a safety precaution. UL and/or FM listings for Steel Suspender require installations with a retaining nut (see performance data and listings as applicable). Suggested drill speed for Steel Suspender installations is 1200 to 1800 rpm. Steel . Wood Install with universal socket driver. Install with universal socket driver Concrete Install with universal socket driver. 1-800-4 DWALY 0 0 0 0 0 z C C 0 0 = = DEWALT PERFORMANCE DATA ANCHORS & FASTENERS PERFORMANCE DATA Suspender for Steel - Dual Direction UL FM Cat. No. Screw Mount Rod Driver No. Mm. Thick. Max. Thick. Load Description Direction Size In. Direction Pipe PipeIn. Thick. Thick. size Size Vert. & V 4" 0.060 4" 16 ga. PFM22711ON 1/4-20 x 1 #3/nut 3/8 PFM2201300 0.060 0.188 H 4" 0.060" 4" 16 ga. PFM227120N 1/4-20 x 1-1/2" #3/nut Vert. & 3/8 PFM2201300 0.060 0.188 V 4" 0.060" 4" 16 ga. H 4" 0.060" 4" 16 ga. Horiz. PFM227130N 1/4-20 x 1-1/2 #5/nut Vert. & 3/8 PFM2201300 0.125 0.500 V 4" 0.060 4" 16 ga. H 4" 0.060' 4" 16 ga. Horiz. Suspender for Steel - Ultimate Load Capacities when Installed in Steel Cat No. Screw Description Direction Rod 1 Coupler Size ] Steel Gage I Thickness 1 1610.060 His. I 1410.075 lbs. I 1210.105 lbs. I 1/810.125 lbs. 3/1610.187 lbs. 1/410.250 lbs. I 1/210.500 lbs. Suspender For Steel - Vertical PFM22711ON 1/4-20x 1" #3 Vertical 3/8 785 1,140 1,740 2,375 4,695 - - 1/4-20 xl" #3/nut Vertical 3/8 3,435 4,025 4,280 4,690 5,810 - - PFM227120N 1/4-20 x 1-1/2" #3 Vertical 3/8 785 1,140 1,740 2,375 4,695 - - 1/4-20 x 1-1/2" #3/nut Vertical 3/8 3,435 4,025 4,280 4,690 4,695 - - PFM227130N 1/4 -20 x 1-1/2" #5 Vertical 3/8 -I - - 3,675 5,205 5,205 1/4-20 x 1-1/2" #5/nut Vertical 3/8 3,435'' 4,025 _ 1 4280 400 ________ 5,810 5,810 5,810 Suspender For Steel - Horizontal PFM22711ON 1/4-20x 1"#3 Side 3/8 1,740 1,945 2,420 2,570 2,810 - - 1/4-20 xl" #3/nut Side 3/8 2,755 2,810 2,570 2,810 2,810 - - PFM227120N 1/4-20x1-1/2"#3 Side 3/8 1,740 1,945 2,420 2,570 2,810 - - 1/4-20x1-1/2" #3/nut Side 3/8 2,755 2,810 2,570 2,810 2,810 - - PFM227130N 1/4-20x 1-1/2"#S Side 3/8 - - - - 2,205 2,810 2,810 1/4-20 x 1-1/2" #5/nut Side 3/8 2,755 1 2,810 1 2,570 1 2,810 2,810 510 2,810 1, The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 3,0 or greater to determine the allowable working load. 2. The strength of the threaded rod used with the Suspender anchors must be considered when determining the controlling load capacity of the assembly. Suspender for Wood - Ultimate Load Capacities when Installed in Wood',' Cat. No I S(Ow Mount DirectinCoupler Rod 1 I Driver No. I FM -T I Ultimate Tension Load UI. ~M. Pipe Size I Max. Pipe Size Size J _______Description Suspender For Wood. Vertical PFM2271000 5/16" x 2-1/2" Vert. I 3/8" I PFM2201300 I 2,670 I 4" I 4" Suspender For Wood - Horizontal PFM2271000 5/16" x2-1/2" Side 3/8" PFM2201300 1,450 3" I - Ultimate Loads In Douglas Fir, Pine and Spruce Truss/joist manufacturers may require pre-ddlled holes with wood depending on the location of the anchor installation. Consult with the truss,ioist manufacturer for details. The values listed above are ultimate load capacities that must be reduced by a minimum safety factor of 3.0 or greater to determine the allowable working load. Suspender for Concrete - Ultimate Load Capacities when Installed in Normal-Weight Concrete',' Cat No. Rod Coupler I Size In. Screw Description Mount Direction I ANSI Drill Bit I Diameter I in. I Embed. Depth I In. Minimum Concrete Compressive Strength (tc) 2,000 psi 4,000 psi _______________ 6,000 psi I Tension I HIS. I Shear I His. Tension His. I Shear HIS. I Tension I lbs. I Shear I HIS. PFM2271050 I 3/8 5/16" x 2-1/4" Vertical 1/4 2-1/4 11760 2,580 2,595 I 2,640 2,770 1 2,700 The values listed above are ultimate load capacities which must be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. Linear interpolation may be used to determine load capacities for intermediate compressive strengths. Suspender for Concrete - Factory Mutual (FM Global) Listings for Pipe Hangers Cat. No. I Rod Coupler Screw Description I Mount Direction I ANSl Drill Bit Diameter I I Embedment Depth I I FM Max. In. i I i in. I in. t I Pipe Size PFM2271050 1 3/8 I 5/16" x 2-1/4" Vertical 1/4 2-1/4 4" www.DEWALTcom ORDERING INFORMATION ANCHORS & FASTENERS ORDERING INFORMATION Susnender for Steel - Dual Direction Cat. No. Description Oliver Rod Size Pack Qty. Carton Uty. PFM22711ON 1/4-20x 1" #3/nut PFM2201300 3/8 25 125 PFM227120N, 1/4-20x 1-1/2 #3/nut PFM2201300 3/8 25 125 PFM227130N 1/4-20 x 1-1/2 #5/nut PFM2201300 3/8 25 125 Susnender for Wood - Dual Direction Cat Ho. Description Driver # Rod Size Pack Oty. Carton Qty. PFM2271000 5/16 x 2-1/2 PFM2201300 3/8 25 125 Susnender for Concrete - Dual Direction Cat No. Description Driver I Rod Size Pack Qty. I Carton Qty. PFM2271050 5/16 x 2-1/4 PFM2201300 1 3/8 25 1125 Concrete Installation Accessories and Tool Guide Cat No. Description Drilling Rotary Hammer SDS+ Bit _ PFM2271050 DCH273P2DH DW5517 Steel and Wood Installation Accessories Cat No. Description Pack (fly. PFM2201100 Hangermate/Suspender Pole Tool Kit 1 The pole tool kit is designed for use with standard 1/2 steel conduit tubing (Conduit not included) and can be customized to various lengths and Ceiling heights. Universal Installation Accessories Cat. No. Description Pack Qty. PFM2201300 Universal Socket Driver 1 PFM2201050 3/8 to 1/2 Adapter 1 The 3/8 to 1/2 adaptor has a 3/8-16 external thread and a 1/2-13 internal thread. a 0 0 0 0 = z C C = C 0 1-800-4DiWAEt cI) RL INTERNAL THREAD VERSION Unified coarse thread (UNC) ANCHOR MATERIALS Zinc Plated carbon steel body ANCHOR SIZE RANGE (TYR) 1/4°, 3/8 and 1/2' diameters SUITABLE BASE MATERIALS Normal-weight concrete Lightweight concrete Concrete over steel deck CODE LISTEI) ICC-ES_ESR-2272 CONCRETE GENERAL INFORMATION GENERAL INFORMATION SNAKE+® Internally Threaded Screw Anchor The Snake+ anchor is an internally threaded, self-tapping screw anchor designed for performance in cracked and uncracked concrete. Suitable base materials include normal-weight concrete, lightweight concrete and concrete over steel deck. The Snake+ screw anchor is installed into a drilled hole with a power tool and a Snake+ setting tool. After installation a steel element is threaded into the anchor body. DEWALT ANCHORS & FASTENERS SECTION CONTENTS General Information.........................1 Material Specifications...................1 Installation Specif ications .............. 2 Installation Instructions..................3 Strength Design Information .......... 4 Design Strength Tables (SD)...........6 Redundant Fastening......................7 Performance Data (ASD).................9 Ordering Information.......................9 Suspending conduit, cable trays and strut Interior low level corrosion environment Tension zone / cracked concrete Seismic attachments (SDC A - F) Fire sprinklers and pipe supports Suspended lighting SNAKE+ + Cracked concrete approved alternative to a dropin anchor + Designed for use in holes. drillad.with standard ANSI carbide drill bits + Anchor design allows for shallow -embedment and mechanically inte?IbckS With base material + Internally threaded anchor for easy adjustment and removability of threaded rod or bolt + Fast anchor installation with a powered impact wrench + Hammer not used for installation APPROVALS AND LISTINGS International Code Council, Evaluation Service (ICC-ES), ESR-2272 for concrete; code compliant with the 2021 IBCRC, 2018 IBCR, 2015 IBCARC and 2012 IBC/]RC. Tested in accordance with ACI 355.2 and ICC-ES AC1 93 for use in concrete under the design provisions of ACI 318 (-19 and -14) Chapter 17 or ACI 318-11 (Appendix D) Evaluated and qualified by an accredited independent testing laboratory for recognition in cracked and uncracked concrete including seismic and wind loading (anchor Category 1) Evaluated and qualified by an accredited independent testing laboratory for reliability against brittle failure, e.g. hydrogen embrittlement Evaluated and qualified by an accredited independent testing laboratory for supplemental recognition in redundant fastening applications FM Global (Factory Mutual) - 3/8 diameter, see FM Approval Guide Pipe hanger components for automatic sprinkler systems CSI Divisions: 03 16 00 - Concrete Anchors and 05 05 09 - Post-Installed Concrete Anchors. Internally threaded anchors shall be Snake+ as supplied by DEWALT, Towson, MD. Anchors shall be installed in accordance with published instructions and the Authority Having Jurisdiction. MATERIAL SPECIFICATIONS Anchor Component I Specification Anchor Body Case hardened carbon steel Plating Zinc plating according to ASTM B633, SC1 Type Ill (Fe/Zn 5) Minimum plating requirements for Mild Service Condition www.DEWALTcom ANCHORS & FASTENERS INSTALLATION SPECIFICATIONS INSTALLATION SPECIFICATIONS Installation Information for Snake+ Screw Anchor Anchor Nominal Anchor Size I Threaded Coupler Diameter (inch) Setting Information No ti taon ns Units 1/4 3/8 1/2 Nominal outside anchor diameter d0 in. 0.375 (9.5) 0.500 (12.7) 0.750 (mm) (19.1) Internal thread diameter (UNC) d in. 0.250 0.375 0.500 (mm) (6.4) (9.5) (12.7) Minimum diameter of hole clearance in fixture for d in. 5/16 7/16 9/16 steel insert element _(following _anchor Nominal Nominal drill bit diameter (ANSI) dbft in. 3/8 1/2 3/4 Minimum hole depth h, in. 2 2 2-1/2 (mm) (51) (51) (64) Overall anchor length in. 1-1/4 1-1/4 1-11/16 (mm) (32) (32) (43) Minimum nominal embedment depth' hnom in. 1-5/8 1-5/8 2-3/16 (mm) (41) (41) (55) Effective embedment hes in. (mm) Not Applicable' 1.10 (28) 1.54 (39) Max impact wrench power (torque) Twe. ft.-lb. -m) 120 (163) 345 (468) 345 (N (468) Max tightening torque of steel insert element Tm ft-lb. 4 8 36 (threaded rod or bolt) - (N-m) (6) (11) (49) Approximate internal thread depth . in. 11/32 . - 23/32 - 15/16 - Anchors Installed In Concrete Construction' Minimum member thickness' hmi, in. (mm) Not Applicable' 4 (102) 4 (102) Minimum edge distance' cr,, in. Not Applicable'(mm) (76) (102) Minimum spacing distance' Smin in. (mm) Not Applicable' 3 (76) 4 (102) Anchors Installed in the Topside of Concrete-Filled Steel Deck Assemblies' Minimum member topping thickness hmmn,uecu in. (mm) Not Applicable' 3-1/4 (83) - Minimum edge distance cmmn,x,tw in. (mm) Not Applicable' 3 (76) - Minimum spacing distance . 5rn1n,w.t in. (mm) Not Applicable' 3 (76) - The information presented in this table is to be used in conjunction with the design criteria of 318 (-19 or -14) Chapter 17 or ACI 318-11 Appendix 0, as applicable, For installations through the soffit of steel deck into concrete, see installation detail. Anchors in the lower flute maybe installed with a maximum 1-inch offset in either direction from center of the flute. In addition, anchors shall have an axial spacing along the flute equal to the greater of 3hf or 1.5 times the flute width. The 1/4-inch diameter anchor is limited to redundant fastening design only. For 3/8-inch diameters installed in the topside of concrete-filled steel deck assemblies, steel installation detail. Dimensional Sketch for Snake+ Screw Anchor Installed with Steel Insert Element Do not exceed 0 = 0 = i C 1-800-4 DEWALT (-3 fB_ -4 = INSTALLATION INSTRUCTIONS ANCHORS & FASTENERS INSTALLA11ON INSTRUCTIONS Step 1 Step 2 Step 3 Step 4 Using the proper drill bit size, drill a hole Select a powered impact wrench that Drive the anchor into the hole until the Insert threaded rod or a bolt into the into the base material to the required does not exceed the maximum torque, shoulder of the Snake+ setting tool Snake+, taking care not to exceed the depth (e.g. dust extractor, hollow bit), T.w, for the selected anchor diameter. comes into contact with the surface maximum specified tightening torque of The tolerances of the carbide drill bit Attach the Snake+ setting tool supplied of the base material. Do not spin the the steel insert element, Tera. Minimum used should meet the requirements of by DEWALT to the impact wrench, setting tool off the anchor to disengage. thread engagement should be at least ANSI Standard B212.15. Mount the anchor onto the setting tool. one anchor diameter. Installation Detail for Snake+ .in the Topside of Concrete-Filled Steel Deck floor and Roof Assemblies 1. 318-inch diameter anchors may be placed in the topside of steel deck profiles provided the minimum topping thickness, minimum spacing distance and minimum edge distance are satisfied as given in the installation information table. SAND-LIGHTWEIGHT CONCRETE OR NORMAL WEIGHT CONCRETE OVER STEEL DECK (MINIMUM 2,500 PSI) Snake, Anchor MV. 3-1/4 : Mln.4-I.(lyp) I Upper flute (Valley) No. 20 Gauge Steel Installation Detail for Snake+ Installed in the Soffit of Concrete over Steel Deck floor and Roof Assemblies 1. Anchors may be placed in the upper flute or lower flute of the steel deck profiles provided in minimum hole clearance Is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in ether direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. STRUCTURAL S000-UOH1WElOHn CONCRETE OR NORMAL WEIGHT CONCRETE OVER STEEL DECK (MINIMUM 3,000 PSI) I' 3" Clearance Min. Upper flute (Valley) Me- 124 u1 Mln.la Werflute (Vidge( (Typ( 1 L Min. 1-1/4 No. 20 Gauge Steel Deck Flute www.DEWALTcom ANCHORS & FASTENERS STRENGTH DESIGN INFORMATION STRENGTH DESIGN INFORMATION Tension Design Information for Snake+ Anchors° CODE LISTEi ICC-ES ESR-2272 j 1-11110-4 UEWALI Design Characteristic Notation Units Nominal Anchor Diameter 318 Inch 1/2 Inch Anchor category 12 or 3 - 1 1 Nominal embedment depth h828 in. 1-5/8 (41) 2-3/16 (mm) (55) STEEL STRENGTH IN TENSION8 ksi ASTM A36 36.0 (248) Minimum specified yield strength of steel insert element fy ASTM A193, 105.0 Grade E17 (724) - Minimum specified ultimate strength ksi ASTM A36 58.0 (4 0) ASTM A193, 125.0 of steel insert element Ua (N/mm2) Grade B7 (862) - Effective tensile stress area of steel insert element A, N in' (mni2) 0.0775 (50) 9 ASTM A36 4.495 8,230 Steel strength in tension Nm lb (20.0) (37.0) ASTM Al 93, 9,685 Grade B7 (43.1) - Reduction factor for steel strength' - 0.65 CONCRETEBREAKOUT STRENGTH IN TENSION8 . Effective embedment het n. (mm) . i.ib (28) 1.54 (39) Effectiveness factor for uncracked concrete k, - 24 30 Effectiveness factor for cracked concrete F k63 - 17 24 Modification factor for cracked and uncracked concretes I'C,N - 1.0 Critical edge distance (uncracked concrete) cm in. (76) (102) Critical edge distance, topside of concrete-filled in. 3 steel decks with minimum topping thickness° Cas.decKtop (mm) (76) - Reduction factor for concrete breakout strength' 0 - Condition B = 0.65 PULLOUT STRENGTH IN TENSION' Characteristic pullout strength, uncracked concrete (2,500 psi)' N "' lb (kN) See note 7 See note 7 Characteristic pullout strength, N 31,C1 lb See note 7 1,665 cracked concrete (2,500 psi)' . (kN) (7.4) Reduction factor for pullout strength' - 0.65 (Condition B) PULLOUT STRENGTH IN TENSION FOR SEISMIC APPLICATIONS' Characteristic pullout strength, seismic (2,500 psi)' Npeq , lb f See note 7 1,665 Reduction factor for pullout strength' 1 0] - Condition B = 0.65 PULLOUT STRENGTH IN TENSION FOR SOFFIT OF SAND-LIGHT WEIGHT AND NORMAL-WEIGHT CONCRETE OVER STEEL DECK Characteristic pullout strength, N p,56268 lb 1,515 1,625 uncracked concrete over steel deck',' (kN) (6.7) (7.2) Characteristic pullout strength, N lb / 1,075 ' 1,300 cracked concrete over steel deck69 (kN) (4.8) (5.8) Characteristic pullout strength, N lb 1,075 1,300 cracked concrete over steel deck, seismic" ((<N) (4.8) (5.8) Reduction factor for pullout strength, concrete over steel deck' - ' Condition B = 0.65 For SI: 1 inch = 25.4 mm, 1 ksi = 6.894 N/mm2; 1 ibf = 0.0044 kN. The data in this table is intended to be used with the design provisions of ACI 318 (-19 and -14) Chapter 17 or ACI 318-11 Appendix D, as applicable; for anchors resisting seismic load combinations the additional requirements of ACI 318-1917.10, ACI 318-14 17.2.3 or ACI 318-11 0.3.3, as applicable, must apply. Installation must comply with published instructions and details. All values of 0 were determined from the load combinations of IBC Section 1605.2, ACI 318 (-19 and -14) Section 5.3 or ACI 318-11 Section 9.2. If the load combinations ACI 318-11 Appendix C are used, the appropriate value of 0 must be determined in accordance with ACI 318-11 0.4.4. For reinforcement that meets ACI 318 (-19 and -14) Chapter 17 or ACI 318-11 Appendix D, as applicable, requirements for Condition A, see ACI 318-19 17.5.3, ACI 318-14 17.3.3(c) or ACI 318-11 0.4.3(c), as applicable, for the appropriate 0 factor. it is assumed that the threaded rod or bolt used with the Snake+ anchor is a ductile steel element with minimum specified properties as listed in the table or an equivalent steel element. The Snake+ anchor is considered a brittle steel element in tension as defined by MCI 318 (-19 and -14) 2.3 or ACI 318-11 0.1, as applicable. Tabulated values for steel strength in tension must be used for design. For all design cases use VN = 1.0. The appropriate effectiveness factor for cracked concrete (}v) and uncracked concrete (kr( must be used. For all design cases use k/An = 1.0. For concrete compressive strength greater than 2,500 psi, Nw = (pullout strength from table)*(specified concrete compressive strengthf2,500(66. For concrete over steel deck the value of 2,500 must be replaced with the value of 3,000. Pullout strength does not control design of indicated anchors. Do not calculate pullout strength for indicated anchor size and embedment. Anchors are permitted to be used in lightweight concrete provided the modification factor A8 equal to 0.8A. is applied to all values of 45c affecting N6 and V8. A shall be determined in accordance with the corresponding version of ACI 318. For anchors installed in the soffit of sand-lightweight concrete-tilled steel deck and floor and roof assemblies, further reduction of the pullout values provided in not required. Values for Np,dmk are for sand-lightweight concrete (f'c,min = 3,000 psi( and additional lightweight concrete reduction factors need not be applied. In addition, evaluation for the concrete breakout capacity in accordance with ACI 318-19 17.6.2, ACI 318-14 17.4.2 or ACI 318-11 D.5.2, as applicable, is not required for anchors installed in the deck soffit (flute). Anchors are permitted in the topside of concrete-filled steel deck assemblies in accordance with the Installation Assemblies with Minimum Topping Thickness.. Detail for Anchors in the Top of Concrete Over Steel Deck Floor and Root INSTALLATION INSTRUCTIONS Shear Design Information for Snake+ Anchors',' DEWALT ANCHORS & FASTENERS [CODE LISTII) (_ICC-ES ESR-2272 18 Nominal Anchor Diameter Design Characteristic Notation Units 3/8 Inch 1/2 inch Anchor category 1,2 013 - 1 1 Nominal embedment depth hoom in. 1-5/8 (41) 2-3/16 (mm) (55) STEEL STRENGTH IN SHEAR' ASTM A36 770 1,995 Steel strength in shear' VW lb (34) (8.9) ASTM A193, 1,655 () Grade B7 (7.4) - Reduction factor for steel strength' - 0.60 STEEL STRENGTH IN SHEAR FOR SEISMIC APPLICATIONS ASTM A36 770 1,995 Steel strength in shear, seismic' V,m lb (3.4) (8.9) ASTM Al 93, 1,655 (k Grade B7 (7.4) - Reduction factor for steel strength - Condition B = 0.60 CONCRETE BREAKOUT STRENGTH IN SHEAR' Nominal outside anchor diameter da in.0,500 0.750 . Load bearing length of anchor - - 1.54 1.10 - - . Reduction factor for concrete breakout strength' - Condition B = 0.70 PRYOUT STRENGTH IN SHEAR' Coefficient for pryout strength km - 1.0 1.0 Effective embedment he Reduction factor for pryout strength' Condition B = 0.70 STEEL STRENGTH IN SHEAR FOR SOFFIT OF SAND-LIGHT WEIGHT AND NORMAL-WEIGHT CONCRETE OVER STEEL DECK' ASTM A36 770 1,995 Steel strength in shear, concrete over steel deck' V.d lb (3.4) (8.9)mk ASTM Al 93, 1,655 () Grade B7 (7.4) - ASTM A36 770 t995 Steel strength in shear, concrete over steel deck, seismic8 lb ASTM A193, 1,665 Grade 87 (7.4) - Reduction factor for steel strength, seismic' - Condition B = 0.60 For Si: 1 inch = 25.4 mm, 1 lbf = 0.0044 kN. The data in this table is intended to be used with the design provisions of AC! 318-14 Chapter 17 or ACI 318-11 Appendix D, as applicable; for anchors resisting seismic load combinations the additional requirements of AC! 318-19 17.10, ACI 318-14 17,2.3 or ACI 318-11 0.3.3 shall apply. Installation must comply with published instructions and details. All values of 0 were determined from the load combinations of IBC Section 1605.2, AC! 318 1-19 and -141 Section 5.3, or ACI 318-11 Section 9.2, asapplicable. If the load combinations of ACI 318-11 Appendix C are used, the appropriate value of 0 must be determined in accordance with AC! 318-11 0.4.4. For reinforcement that meets ACI 318 (-19 and -14) Chapter 17 or ACI 318-11 Appendix 0, as applicable, requirements for Condition A, see ACI 318-19 17.5.3, ACI 318-14 17.3.3(c) or ACI 318-11 0.4.3(c), as applicable, for the appropriate 0 factor. If is assumed that the threaded rod or bolt used with the Snake+ anchor will be a ductile steel element as defined by ACI 318 (-19 and -14) 2.3 or ACI 318-11 0.1, as applicable. Tabulated values for steel strength in shear must be used for design. These tabulated values are lower than calculated results using equation 17.7.1.2b in ACI 318-19 17.5.1 .2b in ACI 318- 14, 0-29 in ACI 318-11, and AC! 318-14 17.5.1.2 or ACI 318-11 0.6.1.2, as applicable. Anchors are permitted to be used in lightweight concrete provided the modification factor Aa equal to 0,8,2.. is applied to all values of affecting Ne and V. )( shall be determined in accordance with the corresponding version of ACI 318. For anchors installed in the soffit of sand-lightweight concrete-filled steel deck and floor and roof assemblies, further reduction of the pullout values provided in not required. Tabulated values for steel strength in shear are for seismic applications and based on test results in accordance with ACI 355.2 Section 9.6. Tabulated values for Vma, are for sand-lightweight concrete )f'c,min = 3,000 psi) and additional lightweight concrete reduction factors need not be applied. In addition, evaluation for the concrete breakout capacity in accordance with AC! 318-19 17.7.2, ACI 318-14 17.5.2 or ACI 318-11 0.6.2, as applicable, and the pryout capacity in accordance with AC! 318-19 17.7.3, AC! 318-14 17.5.3 or ACI 318-11 0.6.3 are not required for anchors installed in the deck soffit (flute). Shear loads for anchors installed through steel deck into concrete may be applied in any direction, www.DEWALTcom Tension and Shear Design Strengths for Snake+ Anchors Installed in Uncracked Concrete, 2A4,5,6 6) DEWALT ANCHORS & FASTENERS DESIGN STRENGTH TABLES (SD) DESIGN STRENGTH TABLES (SD) Tension and Shear Design Strengths for Snake+ Anchors Installed in Cracked Concrete'-'.',','.'-' 6) steel Minimum Concrete Compressive Strength, fc (psi) Nominal Anchor Nominal Embed. insert Element 2,500 I 3,000 I 4,000 I 6,000 ______________________________________________ I 8,000 Olin q5Nn thin I I q5Nn I Nn (/)Nn I 'bVn I I I Size (In.) i (In.) (Threaded Rod or BOlt) Tension shear Tension Shear Tension Shear Tension Shear Tension Shear (lbs.) (lbs.) (lbs.) I (lbs.) I (lbs.) (lbs.) (lbs.) (lbs.) (lbs.) bs.) ASTM A36 635 III 700 tIII 805 1111 985 liii 1,140 1•II 3/8 1-5/8 ASTMA193 Grade B7 635 685 700 805 870 985 1,065 1,140 IJY 1/2 2-3/16 ASTMA36 1,080 1,185 Wtk 1,370 • 1,675 935 1 Kt1. 0- Anchor Pulloutmout Strength Controls 0- Concrete Breakout Strength Controls U - Steel Strength Controls 1 - Tabular values are provided for illustration and are applicable for single anchors installed in normal-weight concrete with minimum slab thickness, ha = hmu, and with the following conditions: - car is greater than or equal to the critical edge distance, cac (table values based on car = ca,). - ca2 is greater than or equal to 1.5 times car. Calculations were performed according to ACI 318-19 Chapter 17. The load level corresponding to the controlling failure mode is listed. (e.g. For tension: steel, concrete breakout and pullout; For shear: steel, concrete breakout and pryout). Furthermore, the capacities for concrete breakout strength in tension and pryout strength in shear are calculated using the effective embedment values, hef, for the selected anchors as noted in the design information tables. Please also reference the installation specifications for more information. Strength reduction factors (0) were based, on ACI 318-19 Section 5.3 for load combinations. Condition B is assumed. Tabular values are permitted for static loads only, seismic loading is not considered with these tables. For designs that include combined tension and shear, the interaction of tension and shear loads must be calculated in accordance with ACI 318-19 Chapter 17. Interpolation is not permitted to be used with the tabular values. For intermediate base material compressive strengths please see ACI 318-19 Chapter 17. For other design conditions including seismic considerations please see ACI 318-19 Chapter 17. For seismic design in accordance with ACI 318, the tabulated tension design strengths for concrete breakout and pullout must be multiplied by a factor of 0.75. 1-800-4 DiWALt REDUNDANT FASTENING ANCHORS & FASTENERS REDUNDANT FASTENING Redundant Fastening Applications For an anchoring system designed with redundancy, the load maintained by an anchor that experiences failure or excessive deflection can be transmitted to neighboring anchors without significant consequences to the fixture or remaining resistance of the anchoring system. In addition to the requirements for anchors, the fixture being attached shall be able to resist the forces acting on it assuming one of the fixing points is not carrying load. It is assumed that by adhering to the limits placed on n1, n2 and n3 below, redundancy will be satisfied. Anchors qualified for redundant applications may be designed for use in normal weight and sand-lightweight cracked and uncracked concrete. Concrete compressive strength of 2,500 psi shall be used for design. No increase in anchor capacity is permitted for concrete compressive strengths greater than 2,500 psi. The anchor installation is limited to concrete with a compressive strength of 8,500 psi or less. Redundant applications shall be limited to structures assigned to Seismic Design Categories A or B only. Redundant applications shall be limited to support of nonstructural elements. [ Number of Anchorage Points of co ,. 7,,17 I I At m l I I Leasti I I Anchor - '3 I '3 I n3 Per Anchorage fl Point ) Linear Element Strength Design (Redundant Fastening): For strength design, a redundant system is achieved by specifying and limiting the following variables n1 = the total number of anchorage points supporting the linear element 112 = number of anchors per anchorage point n3 = factored load at each anchorage point, lbs., using load combinations from IBC Section 1605.2.1 or ACI 318 (-19 and -14) Section 5.3 or ACl 318-11 Section 9.2, Strength Design (SD) Design values for use with strength design shall be established taking or,, • Fra. See redundant fastening design information table for Snake+ design resistance. Allowable Stress Design (Redundant Fastening): Design values for use with allowable stress design shall be established taking Rd, ASD = Ora • F Where o is the conversion factor calculated as the weighted average of the load factors from the controlling load combination. For example, the conversion factor, o is equal to 1.4 assuming all dead load. z www.DEWALTcom ANCHORS & FASTENERS REDUNDANT FASTENING Installation Information for Snake+ Screw Anchor in Redundant Fastening Applications Anchor Property! Notation Units Nominal Anchor Size I Threaded Couplier Diameter (Inch) 1/4 3/8 1/2 Setting Information Nominal drill bit diameter (ANSI) db,t in. 3/8 1/2 3/4 Nominal embedment depth hnom in. 1-5/8 (41) 1-5/8 (41) 2-3/16 (mm) (55) Effective embedment her in. 1.10 1.10 1.54 (mm) (28) (28) (39) Minimum hole depth h0 in, 2 (51) 2 (51) 2-1/2 (mm) (64) Minimum concrete member thickness hmv in. (mm) 3 (76.2) 3 (76.2) 3 (76.2) Overall anchor legnth anCh in. 1-1/4 1-1/4 1-11/16 (mm) (32) (32) (43) Minimum edge distance, redundant fastening' cer3 Cac in. (mm) 4 (102) 4 (102) 4 (102) Minimum spacing distance, redundant fastening' 5een in. (mm) 8 (203) 8 (203) 8 (203) Max impact wrench power (torque) T=OW ft-lb. -m) 120 (163) 345 (468) 345 (N (468) Max tightening torque of steel insert element ft-lb. 4 8 ' '- .- 36 (threaded rod or bolt) (N-m) (6) (11) (49) Approximate internal thread depth - in. (mm) 11/32 23/32 15/16 1. Tabulated minimum spacing and edge distances are applicable only for redundant fastening applications. Redundant Fastening Design Information for Snake+ Anchors123 Anchor Property! Notation Units Nominal Anchor Size __________________ 1/4" 3/8" 1/2" Setting Information Anchor category 1,2or3 - 1 1 1 Nominal I omina embedment depth hnem in. 1-5/8 1-5/8 2-3/16 (mm) (41) (41) (55) CHARACTERISTIC STRENGTH (RESISTANCE) INSTALLED IN CONCRETE' Number of Number of Number of anchorage points anchorage points anchorage points Resistance, cracked or uncracked concrete Fm lb ni ~t 4 n, ~ 3 n, ~ 4 n, ~! 3 ni ~! 4 ni 2! (2 500p5i) <N) 550 360 675 450 675 450 1 (2.5) (1.6) (3.0) (2.0) (3.0) (2.0) Streng)h reduction factor - 0,65 CHARACTERISTIC STRENGTH (RESISTANCE) FOR SAND-LIGHTWEIGHT AND NORMAL WEIGHT CONCRETE OVER STEEL DECK' Number of Number of Number of anchorage points anchorage points anchorage points Resistance, cracked or uncracked concrete over steel deck (2,500 psi) Fm.dk lb N) ni ~t 4 n, ~t 3 n, ~: 4 ni ,? 3 n, ~! 4 ni 2: 3 550 360 1 675 450 675 450 (2.5) (1.6) (3.0) (2.0) (3.0) (2.0) Strength reduction factor3 - 0.65 For SI: 1 inch = 25.4 mm, 1 lbf = 0.0044 kId. The data in this table is intended to be used with the design provisions of Section 4.3 of this report; loads may be applied in tension, shear or any combination thereof. Installation must comply with published instructions and this report. All values of q were determined from the load combinations of IBC Section 1605.2, ACI 318 (-19 and -14) Section 5.3 or ACI 318 (-11) Section 9.2, as applicable. his assumed that the threaded rod or bolt used with the Snake+ anchor has properties as listed in Tension Design Information table. Anchors are permitted to be used in lightweight concrete provided the design strength 0. F is multiplied by the modification factor .4 The modification factor A,a is equal to 0.8A., ,, shall be determined in accordance with the corresponding version of ACI 318. For anchors installed in the soffit of sand-lightweight concrete-tilled steel deck and floor and roof assemblies, farther reduction of the pullout values provided in not required. For installations through the soffit of steel deck into concrete see the installation detail. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from center of the flute. In addition, anchors shall have an axial spacing along the flute equal to the greater of 3het or 1.5 times the flute width. 1-800-4 DEWALT PERFORMANCE DATA (ASD) ANCHORS & FASTENERS PERFORMANCE DATA Ultimate Tension Load Capacities for Snake+ Anchors in Normal-Weight Concrete1234 Minimum Concrete Compressive Strength Nominal Minimum Embedment t'c = 2,500 psi (17.2 MPa) Vc = 3,000 psi (20.7 MPa) f'c = 4,000 psi (20.7 MPa) f'c = 6,000 psi (41.4 MPa) Anchor Diameter Depth Tension Shear Tension Shear Tension Shear Tension Shear In. (n'jn) lbs. His. His. lbs. lbs. lbs. lbs. lbs. 0(N) 0(N) 0(N) (kN) (kN) (kN) 0(N) 1/4 1-5/8 2,130 1,045 2,335 1,045 2,335 1,045 (41) (9.5) (46) (10.4) (4.6) (10.4) (4.6) - 3/8 1-5/8 2,165 1,045 2,370 1,045 2,735 1,045 3,190 1,045 (41) (9.7) (4.6) (10.6) (4.6) (10.6) (4.6) (14.2) (4.6) 1/2 2-3/16 5,590 2,050 6,125 2,050 7,075 2,050 7,240 2,050 (55) (24.9) (9.1) (27.3) (9.1) (27.3) (9.1) (32.0) (9.1) Tabulated load values are for anchors installed in uncracked concrete. Concrete compressive strength must be at the specified minimum at the time of installation. Ultimate load capacities must be reduced by a minimum safety factor of 4.0 or greater to determine allowable working load. The tabulated load values are applicable to single anchors in uncracked concrete installed at critical spacing distance between anchors and at critical edge distance. Ultimate shear capacity is controlled by steel strength of ASTM A36 element (or equivalent(. ORDERING INFORMATION Carbon Steel Snake+ Screw Anchor t. No Nominal Anchor Size Internal Thread Size (UNC) Anchor Outside Diameter Std. Pack Std. Ctn. - 6400SD-PWR 1/4" 1/4 -20 3/8" 100 1,000 6401SD-PWR 3/8" 3/8-16 1/2" 50 500 6403S0-PWR 1/2" 1/2-13 3/4" 50 300 1. Each bm comes with one setting tool. Setting Tool for Snake+ Screw Anchor Cat No. Nominal Anchor Size Std. Pack 6402SD-PWR 1/4" 1 6407SD-PWR 3/8' 1 6404SD-PWR 1/2 1 -- --7~72'77 - ,-.': -- Impact Wrench Selection Guide Nominal Anchor Diameter (Inch) Anchor Setting Information 1/4" 3/8" 112" Max Impact Wrench Power 120 ft-lbs 345 ft-lbs 345 ft-lbs Full Speed I Speed 1 Speed 1 Speed 2 Speed 1 I Speed 2 Tool Setting I Speed and Cat. No. DCF902 DCF923, DCF891, DCF911,DCF913, DCF923, DCF891, DCF911, DCF913, Suggested 20V Max Impact Wrench, DCF921 DCF922, DCF921, 00F922, I DCF921, DCF922, I DCF923, DCF891, D0F892, DCF900 D900 CF892 DCF900 0CF892 DEWALT Impact Wrenches T yrr i Y_ Y-, Cat. No. DCF901 I DCF903 I DCF911 I 0CF913 I DCF921 0CF922 DCF923 I DCF891 I DCFOS2 I f ier Anvil Size 3/8" 1/2" 3/8" 1/2" 1/2" 3/8" 1/2" 1/2" 1/2" Anvil Type Hog Ring Hog Ring Hog Ring Hog Ring Hog Ring Detent Hog Ring Hog Ring I Detent Speed 1: MAX I Speed 1: I Speed 1: Speed 1: Speed 1: 100 ft-lbs. I 100 ft-lbs. I Fastening Speed 1: Speed 1: Speed 1: Speed 1: 100 ft-lbs 100 ft-lbs 100 ft-lbs Speed 2: I Speed 2: I Torque 250 ft-lbs 250 ft-lbs 250 ft-lbs 250 ft-lbs Speed 2: Speed 2: Speed 2: 300 ft-lbs. I 300 ft-lbs. I 300 ft-lbs 300 ft-lbs 300 ft-lbs Speed 3: I Speed 3: I 600 ft-lbs I 600 ft-lbs I www.DEWALTcom 3 Head Box Heavy duty 20 gauge steel construction (6510152) 6 Head Box 6 Large Head Box (6510151A) (6510151) datà!imierext aDk ARGCQ GSUA®RANTEE FIRE SPRINKLER SPARE HEADBOXES 12 Head Box (6510150) Red powder coated finish Knockouts and shelf to accommodate any 1/2" or 3/4" sprinkler head All-welded construction and full length hinge Slotted for easy mounting with screws, rivets or strapping The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the users responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM ARGCO VINYL SPRINKLER IDENTIFICATION DECALS -White Vinyl Crack and Peel Decals with Bright Red Ink. -Available as generic signs or personalized. -ID signs, inspection decals, hydracaic placards and services stickers. AIR CONTROL] ANTI-FREEZES YSTEM ~[REEXTINGUISHER INSPECTORS TEST] 50-20-010 AIR LINE ] 50-20-045 AUXILIARY DRAIN 50-20-200 FIREDEPARTMENTVALVE 50-20-270 MAIN CONTROL 50-20-020 ALARM LINE_] 50-20-070 =CONTROLLVE 50-20-201 FIRE HOSE 50-20-280 MAIN DRAIN 50-20-030 50-20-100 50-20-205 50-20-290 ALARM TEST] DRAIN VALVE FIRE SPRINKLEi1 OPEN SPRINKLER CONTROLL PIPE 50-20-040 50-20-140 50-20-221 50-20-300 FIRE PROTECTION SPRINKLER 8 x 2 50-20-219 50-20-317 TEST& DRAIN 11 50-20-355 ~KRTOR LINE 50-20-390 SPRINKLER SPRINKLER SERVICE STICKERS A Great Way to Advertise Right on the Jobsite *AR Put your Company Name & Logo on your Service Decals A ARGCO's art department can take your personalized artwork and recreate it on your signs - SP RP. MSFIRIPROUCTIWI 24 HR. EMERGENCY SERVICE Custom to your specs. "zt" 770-339-3737 00M10 The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the users responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the users responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM