2800 WHIPTAIL LOOP; ; FPC2024-0078
CPO ityof PERMIT REPORT Carlsbad Print Date: 07/17/2024 Permit No: FPC2024-0078 Job Address: 2800 WHIPTAIL LOOP, CARLSBAD, CA 92010-6751 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel U: 2091203000 Track U: Applied: 05/30/2024 Valuation: $83,000.00 Lot U: Issued: 06/20/2024 Occupancy Group: Project U: Finaled Close Out: 07/17/2024 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check#: INSPECTOR: Cheung, Nathaniel Plan Check #: Project Title: Description: ATX NETWORKS - ADD/MOVE ESFR & QUICK RESPONSE SPRINKLERS TO CORRECT SPACING (28 HEADS) FPContractor: INDUSTRIAL FIRE SPRINKLER CO INC 3845 IMPERIAL AVE SAN DIEGO, CA 92113-1702 (619) 266-6030 FEE AMOUNT FIRE NFPA 13 or 13R System 7-100 heads $695.00 Total Fees: $695.00 Total Payments To Date: $695.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Industrial Fire Sprinkler CO Inc 3845 Imperial Ave San Diego CA 92113 (619) 266 6030 01 Nwdb- S 2800 WRIPTAIL LOOP W., SUITE C CARLSBAD, CA 92010 Material Cut Sheets Worldwide tqca Contacts www.tyco-fire.com Model ESFR-25 252 K-factor Pendent Sprinkler Early Suppression, Fast Response p IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the OR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. r 13 - JfFL* docs.jci.com/tycofire/ model -esfr-25_25-2K General Description The TYCO Model ESFR-25 Pendent Sprinklers are Early Suppression, Fast Response (ESFR) sprinklers with a nominal K-factor of 25.2. The sprinkler assembly is shown in Figure 1. They are suppression-mode sprinklers that are especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting high-piled storage. The Model ESFR-25 Sprinklers are pri- marily used for ceiling-only sprinkler protection of, but not limited to, the fol- lowing storage applications: Most encapsulated or non-encap- sulated common materials including cartoned, unexpanded plastics Uncartoned (exposed) expanded plastics in accordance with NFPA 13 and FM Global standards Some storage arrangements of rub- ber tires, roll paper, flammable liq- uids, aerosols, and automotive components For more specific criteria, see Table B and the applicable design standard. The Model ESFR-25 Pendent Sprin- klers provide the system designer with hydraulic and sprinkler place- ment options not presently available to the traditional ESFR sprinklers having nominal K-factors of 14.0 and 16.8. In particular, the Model ESFR-25 Sprin- kler is designed to operate at substan- tially lower-end head pressures, as compared to ESFR Sprinklers having nominal K-factors of 14.0 and 16.8. This feature offers flexibility when sizing system piping, as well as pos- sibly reducing or eliminating the need for a system fire pump. The Model ESFR-25 Sprinklers can eliminate the use of in-rack sprinklers when protecting high-piled storage of specific materials up to the following heights: NFPA: 40 ft (12,2 m) with ceilings up to 45 ft (13,7m) FM: 45 ft (13,7 m) with ceilings up to 50 ft (15,2 m) For more specific criteria, see Table B and the applicable design standard. The Model ESFR-25 Sprinklers are listed by Underwriters Laboratories (UL) for specific applications with a maximum storage height of 43 ft (13,1 m) with a maximum ceiling height of 48 ft (14,6 m) without the require- ment for in-rack sprinklers. Refer to the Specific Application Listing (UL) for the design criteria. NOTICE The Model ESFR-25 Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any authorities having jurisdiction, such as FM Global. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. In all cases, the appropriate NFPA or FM Global installation standard, or other applicable standard, must be referenced to ensure applicability and to obtain complete installation guide- lines. The general guidelines in this data sheet are not intended to provide complete installation criteria. Sprinkler Identification Number (SIN) See Table A Technical Data Approvals UL and C-UL Listed FM Approved VdS Approved NYC Approved under MEA 356-01-F LPCB Certified (Cert. Nos. 094b and 0071 Page 1 of 6 NOVEMBER 2021 TFP3I2 TFP3I2 Page 2 of 6 1 1" NPT Components: 8 1-13/16 1 - Frame "% El 9/16 (46,0 mm) 2 - Deflector vai.r 'yj (14,3 mm) 3 - Compression NOMINAL I MAKE-IN I I1 2LdZ I 1 I 11 I I Screw LL4 I 4 -Hook 6 5 - Strut 6 - Link Assembly 3-13/16' CENTERLINE 7 - Button 5 (96,8 mm) THERMAL 8 - Sealing SENSING Assembly ELEMENT WRENCH FLATS 3 2 TEMPERATURE RATING - 2 (50,8 mm) —H FIGURE 1 MODEL ESFR-25 PENDENT SPRINKLER, 25.2K EARLY SUPPRESSION, FAST RESPONSE Finish Natural Brass Physical Characteristics Item Description Sprinkler Identification Number (SIN) TY9226 K-factor, gpm/p5i½ (Lpm/bar") 25.2 gpm/p5i½ (362,9 Lpm/bar'/2) Temperature Rating 'F ('C) Thread Size 1 in. NPT or ISO 7-R 1 Sprinkler Orientation Pendent Maximum Working Pressure, psi (bar) 175 psi (12,1 bar) TABLE A MODEL ESFR-25 PENDENT SPRINKLER TECHNICAL DATA Frame .............................Brass Deflector ..........................Bronze Compression Screw ..........Stainless Steel Hook ............................MONEL Strut ............................. MONEL Link Assembly................Solder, Nickel Button ...............Copper/Stainless Steel Sealing Assembly. . Beryllium Nickel w/TEFLON Additional Technical Data See Table A Operation The fusible link assembly is com- prised of two link halves that are joined together by a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, activating the sprinkler and flowing water. Design Criteria The following general guidelines pro- vided for the TYCO Model ESFR-25 Pendent Sprinklers can be used for a quick reference. The National Fire Protection Associa- tion (NFPA) and FM Global (FM Approv- als) provide installation standards that must be used to properly design an automatic sprinkler system utilizing Early Suppression, Fast Response (ESFR) Sprinklers. The guidelines pro- vided by NFPA and FM Global may differ. Consequently, the appropri- ate standard must be used for a given installation. General guidelines are not intended to provide complete installation criteria. In all cases, the appropriate NFPA or FM Global installation standard must be referenced to ensure applicabil- ity and to obtain complete installation guidelines. For more information, see Table B. Roof Construction Unobstructed or obstructed construc- tion, such as smooth ceiling, bar joists, beam and girder. Note: Where the depths of the solid structural members, as in beams and stem, exceed 12 in. (302 mm), install ESFR Sprinklers in each channel formed by the structural members. Ceiling Slope Maximum 2 in. rise for 12 in. run (16.7%) Maximum Coverage Area 100 ft2 (9,3 m2) Minimum Coverage Area 64 ft2 (5,8 m2) per NFPA 13 / FM Global 2-0 Maximum Spacing 12 ft (3,7 m) for building heights up to 30 ft (9,1 m) 10 ft (3,1 m) for building heights greater than 30 ft (9,1 m) Minimum Spacing 8 ft (2,4 m) Minimum Clearance to Commodity 36 in. (914 mm) NFPA Deflector-to-Ceiling Distance 6 in. to 18 in. (152 mm to 457 mm) TFP3I2 Page 3 of 6 Storage Type NFPA FM Global Sprinkler Type ESFR Storage Response Type FR OR System Type Wet Wet Temperature Rating F C) 165F (74-C) 165F (74-C) 212F (100CC) 212'F (100CC) Open Frame (i.e., no solid shelves), Single, Double, Multiple- Row, or Portable Rack Storage of Class l-IV and Group A or Refer to NFPA 13 Refer to FM Global B Plastics 2-0 and 8-9 Solid Pile or Palletized Storage of Class l-IV and Group A or to NFPA 13 Refer to FM GlobalRefer B Plastics 2-0 and 8-9 Idle Pallet Storage Refer to NFPA 13 Refer to FM Global 2-0, 8-9, and 8-24 Rubber Tire Storage Refer to NFPA 13 Refer to FM Global 2-0 and 8-3 Roll Paper Storage (Refer to the Standard) Refer to NFPA 13 Refer to FM Global 8-21 Flammable/Ignitable Liquid Storage (Refer to the Standard) Refer to NFPA 30 Refer to FM Global 7-29 Aerosol Storage (Refer to the Standard) Refer to NFPA 30B Refer to FM Global 7-31 Automotive Components in Portable Racks Refer to NFPA 13 N/A (Control mode only; refer to the Standard) N/A - Not Applicable TABLE B MODEL ESFR-25 PENDENT SPRINKLER COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW FM Global Centerline of Thermal Sensing Element-to-Ceiling Distance Refer to FM Global 2-0 for Storage Sprinklers. Specific Application Listing (UL) TYCO Model ESFR-25 Pendent Sprin- klers are listed by Underwriters Labo- ratories (UL) for Specific Applications with a ceiling height greater than 45 ft (13,7 m) up to and including 48 ft (14,6 m), and a storage arrangement up to and including 43 ft (13,1 m). For guidelines about the TYCO Model ESFR-25 Pendent Sprinkler Specific Applications Listing (UL) Design Crite- ria, see Table C. Installation TYCO Model ESFR-25 Early Suppres- sion, Fast Response 25.2K Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Damage to the fusible link assembly during installation can be avoided by handling the sprinkler by the frame arms only and by using the appropriate sprinkler wrench. Do not apply pres- sure to the fusible link assembly. Failure to do so can lead to an unstable link assembly and premature activation of the sprinkler. Damaged sprinklers must be replaced. A leak-tight 1 in. NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 20 to 30 lb-ft (26,8 to 40,2 Nm). Higher levels of torque can distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Installing the Sprinkler To install the sprinkler, perform the fol- lowing steps: Note: Install the Model ESFR-25 Pendent Sprinkler in the pendent posi- tion as shown in Figure 2. Step 1. With pipe thread sealant applied, hand-tighten the sprinkler into the sprinkler fitting. Do not apply pres- sure to the link assembly, and handle the sprinkler only by the frame arms. Step 2. Wrench-tighten the sprin- kler using only the W-Type 1 Sprinkler Wrench as shown in Figure 2, and by fully engaging (seating) the wrench on the sprinkler wrench flats as shown in Figure 1. Step 3. After installation, inspect the link assembly of each sprinkler for damage. In particular, verify that the link assembly and hook are posi- tioned as shown in Figure 1, and that the link assembly is not bent, creased, or forced out of normal position in any way. Replace damaged sprinklers. TFP3I2 Page 4 of 6 Description Specification, UL Sprinkler Type ESFR Temperature Rating F (CC) 165-F (74CC) 212'F (100CC) Response Type QR Sprinkler Position Pendent, frame arms aligned with pipe, deflectors parallel with ceiling or roof System Type Wet Maximum Area of Coverage 100 ft2 (9,3 m2) Minimum Area of Coverage 64 ft2 (5,8 m2) Maximum Slope Ceiling 2 in. rise for 12 in. run (16.7%) Maximum Spacing 10 ft (3,1 m) Minimum Spacing 8 ft (2,4 m) Deflector Distance from Walls Minimum of 4 in. (100 mm) from walls but no more than 1/2 the allowable distance permitted between sprinklers Deflector to Top of Storage Minimum of 36 in. (914 mm) Deflector to Ceiling Distance 6 in. to 14 in. (152 mm to 356 mm) Maximum Ceiling Height 48 ft (14,6 m) Maximum Storage Height 43 ft (13,1 m) Storage Arrangement Palletized, solid piled, open frame; single row or double row Commodity Class I - IV, Cartoned unexpanded plastic Sprinkler System Design NFPA 13 for ESFR Sprinklers based upon 45 psi (3,1 bar) design pressure 169 gpm (640 Lpm) with 12 sprinkler remote area Obstruction Criteria Reference NFPA 13, Chapter 8 Minimum Aisle Width 5 ft (1,5 m) Hose Stream allowance and Water Supply Duration 250 gpm for 60 minutes (950 Lpm for 60 minutes) TABLE C MODEL ESFR-25 PENDENT SPRINKLER SPECIFIC APPLICATION LISTING (UL) COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW TFP3I2 Page 5 of 6 _<FITTING SIDE TOWARDS SPRINKLER FITTING WRI RE( FIGURE 2 W-TYPE I SPRINKLER WRENCH Care and Maintenance TYCO Model ESFR-25 Early Suppres- sion, Fast Response 25.2K Pendent Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. For more informa- tion, see the Installation section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with the following docu- ments and standards: This technical data sheet Applicable standards of the National Fire Protection Association such as NFPA 25 Standards of any authorities having jurisdiction Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies with 1 in. NPT Thread Connection Specify: Model ESFR-25 (TY9226), K=25.2, Early Suppression, Fast Response Pendent Sprinkler with 1 in. NPT thread connection, (specify) temperature rating, Natural Brass, P/N (specify): 165°F (74°C) ..................58-441-1-165 212°F (100°C) .................58-441-1-214 Special Order Sprinkler Assemblies with ISO 7-1 Thread Connection Specify: Model ESFR-25 (TY9226), K=25.2, Early Suppression, Fast Response Sprinkler with ISO 7-1 thread connection, (specify) temperature rating), Natural Brass, P/N (specify): 165°F (74°C) .................. 58-442-1 -165 212°F (100°C) ................. 58-442-1 -214 Sprinkler Wrench Specify: W-Type 1 Sprinkler Wrench, P/N 56-872-1-025 Page 1 of 5 '41J I Kj CR l:IIEu'1M VK3021 QUICK RESPONSE 0 PENDENT SPRINKLER (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION The Viking VK3021 Quick Response Pendent Sprinkler is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Chart. LISTINGS AND APPROVALS c®us UL Listed: Category VNIV FM FM Approved: Classes 2017, 2015, 2043 Also approved for use in FM Approved vacuum dry sprinkler systems with a maximum supervisory vacuum pressure of -3 PSI (-207 mbar) ( E CE: Standard EN12259-1, DOP_XT1A_1-3-21 Refer to the Approval Chart and Design Criteria for requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 PSI (0.5 bar) Rated to: UL - 250 PSI (24 bar) WWP FM - 175 PSI (12 bar) WWP Factory tested hydrostatically to 500 PSI (34.5 bar) Thread size: 1/2" NPT (15 mm BSPT) WARNING Cancer and Reproductive Harm Nominal K-factor: 5.6 U.S. (80.6 metric*) . wwwP65Wamingscagov Glass-bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in bar. When pressure is measured in kPa, divide the metric Kfactor shown by 10.0. Material Standards: Sprinkler Body: Brass CW602N, UNS-C84400 or QM Brass Deflector: Stainless Steel UNS S30400 Pip Cap Shell - Stainless Steel UNS-544400 Pip Cap Disc - Stainless Steel UNS-S30 100 Belleville Spring - Nickel Alloy Pip Cap Seal - Polytetrafluoroethylene (PTFE) Compression Screw: Brass CW6I2N, CW508L, UNS-C36000 or UNS-C26000 Shipping Cap: Polyethylene Bulb: Glass, nominal 3 mm diameter Ordering Information: (Refer to Table I and the current Viking List Price Book.) INSTALLATION Refer to appropriate NFPA, FM Global, and/or any other applicable installation standards. Risk of permanent damage. Over-tightening the sprinkler can cause permanent damage. > Tighten the sprinkler to a MAXIMUM torque of 14 ft-lbs (19 N-m). OPERATION During fire conditions, when the temperature around the sprinkler reaches its operating temperature, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers are available through a network of domestic and international distributors. See the Viking website for the closest distributor or contact Viking. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_110720 21.04.19 Rev 21 .2 Replaces Form No. F_110720 Rev 21.1 (Added Models E-1, E-2 and E-3 Escutcheons) Page 2 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLE 1: ORDERING INFORMATION Instructions: Using the sprinkler base part number, (1) add the suffix for the desired Finish Size Sprinkler __I (2) add the suffix for the desired Temperature Rating. 1: Finishes 2: Temperature Ratings Description Suffix' Nominal Rating Bulb Color 3 Max. Ambient Ceiling Suffix ase Part NPT BSPT BNumber Inch mm Temperature 23870 1/2 Brass A 135°F(57°C) Orange 100°F(38°C) A 23882 7 15 Chrome F 155°F(68°C) Red 100°F(38°C) B White Polyester 4.6 M-/W 175°F (79 °C) Yellow 150°F (65 °C) D Black Polyester 4.1 M-/B 200°F (93 °C) Green 150°F (65 °C) E ENT 4,5,6 JN 286 °F (141 °C) Blue 225 °F (107 °C) G OPEN -- -- Z Example: 23870MB/W = VK3021 with white polyester finish and 155 °F (68 °C) nominal temperature rating. This sprinkler is to be installed into an area with a maximum ambient temperature of 100°F (38 °C) meaning if the area will experience temperatures above the maximum ambient rating, you shall use a higher temperature-rated sprinkler. Accessories Sprinkler Wrenches (see Figure 1): Standard Wrench: Part number 23559MB Recessed Socket Wrench: Part number 23560MB2 Sprinkler Cabinet: Up to 6 sprinklers: Part number 01724A 6-12 sprinklers: Part number 01725A Footnotes Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. Requires a 1I2 ratchet which is not available from Viking. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. UL Listed as corrosion resistant. FM Approved as corrosion resistant. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. UL Listed for 250 PSI (17 bar) WWP. 7116" (11 mm) Nominal Pipe Engagement I1112" NPT 15mmBSPT Figure 2: Sprinkler Dimensions Figure 1: Sprinkler Wrenches Form No. F_110720 21.04.19 Rev 21.2 Page 3 of 5 N 11(1 VK3021 QUICK RESPONSE PENDENT SPRINKLER (K56) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com APPROVAL CHART Finish(es) Viking Quick Response Pendent Sprinkler Temperature(s) 0 A1X KEY VK3021 K5.6 (80.6 metric) Escutcheon(s) If applicable Thread Size and Approvals2'6 Sprinkler Listings Base Part Number' NPT BSPT cULus FM CE6 Inch mm Approval Listings Maximum WWP Approval Listings Maximum WWP Approval Listings 23870 1/2 -- Al, B2X, B3Y 250 PSI (17 bar) Al, B2X, B3Y 175 PSI (12 bar) Cl, D2X, D3Y 23882 -- 15 Al, B2X, B3Y 250 PSI (17 bar) Al, B2X, 133Y 175 PSI (12 bar) Cl, D2X, D3Y Approved Temperature Ratings: A = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) and 286 °F (141 °C) B = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C = 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 C) and 286 °F (141 °C) D = 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) Approved Finishes: 1= Brass, Chrome, White Polyester 3.4, Black Polyester s", and ENT 4,5 2 = Brass, Chrome, White Polyester s", and Black Polyester 3,4 3 = ENT 5 Approved Escutcheon Code: X = Installed with Viking Recessed Escutcheons Models E-1, E-2, E-3, NP-I, NP-2, and NP-3, or Viking Standard Surface Mounted Escutcheons Y = Installed with Viking Recessed Escutcheons Models E-1 and NP-1, or Viking Standard Surface Mounted Escutcheons Footnotes I Base Part number is shown. For complete part number, refer to Viking's current price schedule. 2 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available upon request with the same Listings and Approvals as the standard colors. cULus Listed as corrosion resistant. FM Approved as corrosion resistant. 6 CE: Standard EN12259-1, Declaration of Performance DOP_XT1A_1-3-21. DESIGN CRITERIA - UL cULus Listinq Requirements: The Viking VK3021 Quick Response Pendent Sprinkler is cULus Listed as indicated in Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers shall be followed. IMPORTANT: Always refer to Form Number F_091699 - Care and Handling of Sprinklers. Also refer to Form Number F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking Technical Data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. DESIGN CRITERIA - FM FM Annroval Requirements: The Viking VK3021 Quick Response Pendent Sprinkler is FM Approved as quick response Non-Storage Pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM Installation guidelines may differ from UL and/or NFPA criteria. IMPORTANT: Always refer to Form Number F_091699 - Care and Handling of Sprinklers. Also refer to Form Number F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking Technical Data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F110720 21.04.19 Rev 21.2 Page 4 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. Install the escutcheon inner ring 2. Carefully slide the wrench** sideways onto the sprinkler threads. around the protective cap then push upwards to engage with the sprinkler wrench flats. t t 3. Install the sprinkler and escutcheon assembly into the pipe fitting. Be sure the escutcheon outer ring contacts the surface of the finished ceiling. Figure 3: Recessed Installation (with Recessed Socket Wrench) A 112" ratchet is required (not available from Viking). 1. Install the escutcheon onto the 2. Carefully slide the wrench onto the 3. Install the sprinkler and escutcheon sprinkler threads. sprinkler wrench flats. assembly into the pipe fitting. Be sure the escutcheon contacts the surface of the finished ceiling. Figure 4: Installation (with Standard Wrench) Form No. F110720 21.04.19 Rev 21.2 Ceiling opening size: Minimum: 2-5/16"(59 mm) Maximum: 2-1/2" (64 6" im) Page 5 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Models E-1 or NP-1 Recessed Escutcheon 2-1/8' (54 mm) Ceiling opening size: Minimum: 2-5/16" (59 mm) Maximum: 2-1/2" (64 mm) Models E-2, E-3, NP-2 or NP-3 Thread- Recessed 2-1/8" (54 mm , Escutcheon (E-3 and NP-3 Outer rings have larger diameters) rL .*4 13/16" 15/16" Max. 1-7/16" (21 mm) Max. 1-3/4" (24 mm) (37 mm) (44 mm) - 4' 1 _ Standard Surface-Mounted Escutcheon Figure 5: Installation Dimensions with Viking Escutcheons Form No. F_110720 21.04.19 Rev 21.2 Replaces Form No. F_110720 Rev 21.1 (Added Models E-1, E-2 and E-3 Escutcheons) Page 1 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com SPRINKLERS ARE FRAGILE - HANDLE WITH CARE! General Handling and Storage: Store sprinklers in a cool, dry place. Protect sprinklers during storage, transport, handling, and after installation. Use the original shipping containers. DO NOT place sprinklers loose in boxes, bins, or buckets. Keep sprinklers separated at all times. DO NOT allow metal parts to contact sprinkler operating elements. For Pre-Assembled Drops: Protect sprinklers during handling and after installation. For recessed assemblies, use the protective sprinkler cap (Viking Part Number 10364). Sprinklers with Protective Shields or Caps: DO NOT remove shields or caps until after sprinkler installation and there no longer is potential for mechanical damage to the sprinkler operating elements. Sprinkler shields or caps MUST be removed BEFORE placing the system in service! Remove the sprinkler shield by carefully pulling it apart where it is snapped together. Remove the cap by turning it slightly and pulling it off the sprinkler. Sprinkler Installation: DO NOT use the sprinkler deflector or operating element to start or thread the sprinkler into a fitting. Use only the designated sprinkler head wrench! Refer to the current sprinkler tech- nical data page to determine the correct wrench for the model of sprinkler used. DO NOT install sprinklers onto piping at the floor level. Install sprinklers after the piping is in place to prevent mechanical damage. DO NOT allow impacts such as hammer blows directly to sprinklers or to fittings, pipe, or couplings in close proximity to sprinklers. Sprinklers can be damaged from direct or indirect impacts. DO NOT attempt to remove drywall, paint, etc., from sprinklers. Take care not to over-tighten the sprinkler and/or damage its operating parts! Maximum Torque: 1/2" NPT: 14 ft-lbs. (19.0 N-m) 3/4" NPT: 20 ft-lbs. (27.1 N-m) 1" NPT: 30 ft-lbs. (40.7 N-m) - '• I ktss1IIS -1 1 S -- I LU CORRECT INCORRECT (Original container used) (Placed loose in box) ______ #• • '.f/'\\ •\i7 INCORRECT (Protected with caps) (Protective caps not used) CORRECT INCORRECT (Piping is in place at the (Sprinkler at floor level) ceiling) 1 TIPSL CORRECT INCORRECT (Special installation (Designated wrench not wrenches) used) WARNING: Cancer and Reproductive Ham, www.P65Wamings.ca.gov A WARNING Any sprinkler with a loss of liquid from the glass bulb or damage to the fusible element should be destroyed. Never install sprinklers that have been dropped, damaged, or exposed to temperatures exceeding the maximum ambient temperature allowed. Sprinklers that have been painted in the field must be replaced per NFPA 13. Protect sprinklers from paint and paint overspray in accordance with the installation standards. Do not clean sprinklers with soap and water, ammonia, or any other cleaning fluid. Do not use adhesives or solvents on sprinklers or their operating elements. Refer to the appropriate technical data page and NFPA standards for complete care, handling, installation, and maintenance instructions. For additional product and system information Viking data pages and installation instructions are available on the Viking Web site at www.vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Replaces Form No. F_091699 Rev 16.1 (Added P65 Warning) Page 2 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com PROTECTIVE SPRINKLER SHIELDS AND CAPS General Handling and Storage: Many Viking sprinklers are available with a plastic protective cap or shield temporarily covering the operating elements. The snap- on shields and caps are factory installed and are intended to help protect the operating elements from mechanical damage during shipping, storage, and installation. NOTE: It is still necessary to follow the care and handling instructions on the appropriate sprin- kler technical data sheets* when installing sprinklers with bulb shields or caps. WHEN TO REMOVE THE SHIELDS AND CAPS: NOTE: SHIELDS AND CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Remove the shield or cap from the sprinkler only after checking all of the following: The sprinkler has been installed*. The wall or ceiling finish work is completed where the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operating elements. SHIELDS AND CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! - . ... ••.,• •• • ::. Figure 1: Sprinkler shield being removed from a pendent sprinkler. Figure 2: Sprinkler cap being removed from a pendent sprinkler. Figure 3: Sprinkler cap being re- moved from and upright sprinkler. HOW TO REMOVE SHIELDS AND CAPS: No tools are necessary to remove the shields or caps from sprinklers. DO NOT use any sharp objects to remove them! Take care not to cause mechanical damage to sprinklers when removing the shields or caps. When removing caps from fusible ele- ment sprinklers, use care to prevent dislodging ejector springs or damaging fusible elements. NOTE: Squeezing the sprinkler cap excessively could damage sprinkler fusible elements. To remove the shield, simply pull the ends of the shield apart where it is snapped together. Refer to Figure 1. To remove the cap, turn it slightly and pull it off the sprinkler. Refer to Figures 2 and 3. Refer to the current sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. Never install sprinklers that have been dropped, damaged, or exposed to temperatures in excess of the maximum ambient temperature allowed. * Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Concealed Sprinkler and Adapter. Assembly (Protective Cap Removed) Concealed Sprinkler and Adapter Assembly with Protective Cap Cover Plate Assembly (Pendent Cover 12381 shown) Page 3 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com CAUTION CONCEALED COVER ASSEMBLIES ARE FRAGILE! TO ASSURE SATISFACTORY PERFORMANCE OF THE PRODUCT, HANDLE WITH CARE. GENERAL HANDLING AND STORAGE INSTRUCTIONS: Do not store in temperatures exceeding 100 °F (38 °C). Avoid direct sunlight and confined areas subject to heat. Protect sprinklers and cover assemblies during storage, transport, handling, and after installation. -- Use original shipping containers. -- Do not place sprinklers or cover assemblies loose in boxes, bins, or buckets. Keep the sprinkler bodies covered with the protective sprinkler cap any time the sprinklers are shipped or handled, during testing of the system, and while ceiling finish work is being completed. Use only the designated Viking recessed sprinkler wrench (refer to the appropriate sprinkler data page) to install these sprinklers. NOTE: The protective cap is temporarily removed during installation and then placed back on the sprinkler for protection until finish work is completed. Do not over-tighten the sprinklers into fittings during installation. Do not use the sprinkler deflector to start or thread the sprinklers into fittings during installation. Do not attempt to remove drywall, paint, etc., from the sprinklers. Remove the plastic protective cap from the sprinkler before attaching the cover plate assembly. PROTECTIVE CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. Form No. F091699 18.10.11 Rev 16.1.P65 Page 4 of 4 KjF.IG ARE AND HANDLING OF SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com USE THE FOLLOWING PRECAUTIONS WHEN HANDLING WAX-COATED SPRINKLERS Many of Viking's sprinklers are available with factory-applied wax coating for corrosion resistance. These sprinklers MUST receive appropriate care and handling to avoid damaging the wax coating and to assure satisfactory performance of the product. General Handling and Storage of Wax-Coated Sprinklers: Store the sprinklers in a cool, dry place (in temperatures below the maximum ambient temperature allowed for the sprinkler temperature rating. Refer to Table 1 below.) Store containers of wax-coated sprinklers separate from other sprinklers. Protect the sprinklers during storage, transport, handling, and after installation. Use original shipping containers. Do not place sprinklers in loose boxes, bins, or buckets. Installation of Wax-Coated Sprinklers: Use only the special sprinkler head wrench designed for installing wax-coated Viking sprinklers (any other wrench may damage the unit). Take care not to crack the wax coating on the units. For touching up the wax coating after installation, wax is available from Viking in bar form. Refer to Table 1 below. The coating MUST be repaired after sprinkler installation to protect the corrosion-resistant properties of the sprinkler. Use care when locating sprinklers near fixtures that can generate heat. Do not install sprinklers where they would be exposed to temperatures exceed- ing the maximum recommended ambient temperature for the temperature rating used. Inspect the coated sprinklers frequently soon after installation to verify the integrity of the corrosion resistant coating. Thereafter, inspect representative samples of the coated sprinklers in accordance with NFPA 25. Close up visual inspections are necessary to determine whether the sprinklers are being affected by corrosive conditions. Sprinkler Temperature Rating (Fusing Point) Wax Part Number I TABLE Wax Melting Point I Maximum Ambient Ceiling Temperature' ' Wax Color 155 °F(68 °C)/ 165 °F(74 °C) 02568A 148 °F (64 °C) 100 °F(38 °C) Light Brown 175 °F (79 °C) 04146A 161 °F (71 °C) 150 °F (65 °C) Brown 200 °F (93 °C) 04146A 161 °F (71 °C) 150 °F (65 °C) Brown 220°F(104°C) 02569A 170°F(76°C) 150°F(65°C) Dark Brown 286 °F(141 °C) 02569A 170°F(76°C) 150°F(65°C) Dark Brown Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. I LWARNING1 Never install sprinklers that have been dropped, damaged, or exposed to temperatures in excess of the maximum ambi- ent temperature allowed. Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Replaces Form No. F_091699 Rev 16.1 (Added P65 Warning) Page 1 of 3 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION Viking fire sprinklers consist of a threaded frame with a specific waterway or orifice size and a deflector for distributing water in a specified pattern. A closed or sealed sprinkler refers to a complete assembly, including the thermosensitive operating element. An open sprinkler does not use an operating element and is open at all times. The distribution of water is intended to extinguish a fire or to control its spread. - Viking sprinklers are available in several models and styles. Refer to specific sprinkler technical data pages for available styles, finishes, temperature ratings, thread sizes, and nominal K-Factors for the particular model selected. LISTINGS AND APPROVALS Refer to the Approval Charts on the appropriate sprinkler technical data page(s) and/or WARNING Cancer and Reproductive Harm approval agency listings. wwwP65Warningscagov TECHNICAL DATA Pressure Ratings: Maximum allowable water working pressure is 175 psig (12 Bar) unless rated and specified for high water working pressure [250 psig (17.2 bar)]. Sprinkler Identification: Viking sprinklers are identified and marked with the word "Viking", the sprinkler identification number (SIN) consisting of "VK" plus a three digit number*, the model letter, and the year of manufacture. Available Finishes: Viking sprinklers are available in several decorative finishes. Some models are available with corrosion-resistant coatings or are fabricated from non-corrosive material. Refer to the sprinkler technical data page for additional information. Available Temperature Ratings: Viking sprinklers are available in several temperature ratings that relate to a specific temperature classification. Applicable installa- tion rules mandate the use and limitations of each temperature classification. In selecting the appropriate temperature classifica- tion, the maximum expected ceiling temperature must be known. When there is doubt as to the maximum temperature at the sprinkler location, a maximum-reading thermometer should be used to determine the temperature under conditions that would show the highest readings to be expected. In addition, recognized installation rules may require a higher temperature classifica- tion, depending upon sprinkler location, occupancy classification, commodity classification, storage height, and other hazards. In all cases, the maximum expected ceiling temperature dictates the lowest allowable temperature classification. Sprinklers located immediately adjacent to a heat source may require a higher temperature rating. K-Factors: Viking sprinklers are available in several orifice sizes with related K-Factors. The orifice is a tapered waterway and, therefore, the K-Factor given is nominal. Nominal U.S. K-Factors are provided in accordance with the 1999 edition of NFPA 13, Section 3-2.3. Refer to the specific data page for appropriate K-Factor information. Available Styles: Viking sprinklers are available for installation in several positions as indicated by a stamping on the deflector. The deflector style dictates the appropriate installation position of the sprinkler; it breaks the solid stream of water issuing from the sprinkler orifice to form a specific spray pattern. The following list indicates the various styles and identification of Viking sprinklers. UPRIGHT SPRINKLER: A sprinkler intended to be installed with the deflector above the frame so water flows upward through the orifice, striking the deflector and forming an umbrella-shaped spray pat- tern downward. Marked "SSU" (Standard Sprinkler Upright) or "UPRIGHT" Viking Technical Data may be found on on the deflector. PENDENT SPRINKLER: A sprinkler intended to be oriented with the deflec- The Viking Corporation's Web site at tor below the frame so water flows downward through the orifice, striking http:I/www.vikinggroupinc.com. the deflector and forming an umbrella-shaped spray pattern downward. The Web site may include a more recent Marked "SSP" (Standard Sprinkler Pendent) or "PENDENT" on the de- edition of this Technical Data Page. flector. CONVENTIONAL SPRINKLER: An "old style" sprinkler intended to be installed with the deflector in either the upright or pendent position. The deflector provides a spherical type pattern with 40 to 60 percent of the water initially directed downward and a proportion directed upward. Must be installed in accordance with installation rules for conventional or old style sprinklers. DO NOT USE ASA REPLACEMENT FOR STANDARD SPRAY SPRINKLERS. Marked "C U/P' (Conventional Upright/Pendent) on the deflector. Form No. F_080814 18.12.06 Rev 14.1.P65 Replaces Form No. F_080814 Rev 14.1 (Added P65 Warning.) Page 2 of 3 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com VERTICAL SIDEWALL (VSW) SPRINKLER: A sprinkler intended for installation near the wall and ceiling. The deflector provides a water spray pattern outward in a quarter-spherical pattern and can be installed in the upright or pendent position with the flow arrow in the direction of discharge. Marked "SIDEWALL' on the deflector with an arrow and the word "FLOW". (Note: Some vertical sidewall sprinklers can only be installed in the upright or pendent position—in this case, the sprinkler will also be marked "UPRIGHT" or "PENDENT".) HORIZONTAL SIDEWALL (HSW) SPRINKLER: A sprinkler intended for installation near the wall and ceiling. The special deflector provides a water spray pattern outward in a quarter-spherical pattern. Most of the water is directed away from the nearby wall with a small portion directed at the wall behind the sprinkler. The top of the deflector is oriented parallel with the ceiling or roof. The flow arrows point in the direction of discharge. Marked "SIDEWALL" and "TOP" with an arrow and the word "FLOW". EXTENDED COVERAGE (EC) SPRINKLER: A spray sprinkler designed to discharge water over an area having the maximum dimensions indicated in the individual listings. Maximum area of coverage, minimum flow rate, orifice size, and nominal K-Factor are specified in the individual listings. EC sprinklers are intended for Light-Hazard occupancies with smooth, flat, horizontal ceil- ings unless otherwise specified. In addition to the above markings, the sprinkler is marked "EC". QUICK RESPONSE (QR) SPRINKLER: A spray sprinkler with a fast- actuating operating element. The use of quick response sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction (AHJ) prior to installing. QUICK RESPONSE EXTENDED COVERAGE (QREC) SPRINKLER: A spray sprinkler designed to discharge water over an area having the maximum dimensions indicated in the individual listing. This is a sprinkler with an operating element that meets the criteria for quick response. QREC sprinklers are only intended for Light Hazard occupancies. The sprinkler is marked "QREC". FLUSH SPRINKLER: A decorative spray sprinkler intended for installation with a concealed piping system. The unit is mounted flush with the ceiling or wall, with the fusible link exposed. Upon actuation, the deflector extends beyond the ceiling or wall to distribute water discharge. The sprinkler is marked "SSP", "PEND", or "SIDEWALL" and "TOP". CONCEALED SPRINKLER: A decorative spray sprinkler intended for installation with a concealed piping system. The sprinkler is hidden from view by a cover plate installed flush with the ceiling or wall. During fire conditions, the cover plate detaches, and upon sprinkler actuation, the deflector extends beyond the ceiling or wall to distribute water discharge. The sprinkler is marked "SSP", "PEND", or "SIDEWALL" and "TOP". RECESSED SPRINKLER: A spray sprinkler assembly intended for installation with a concealed piping system. The assembly con- sists of a sprinkler installed in a decorative adjustable recessed escutcheon that minimizes the protrusion of the sprinkler beyond the ceiling or wall without adversely affecting the sprinkler distribution or sensitivity. Refer to the appropriate technical data page for allowable sprinkler models, temperature ratings, and occupancy classifications. DO NOT RECESS ANY SPRINKLER NOT LISTED FOR USE WITH THE ESCUTCHEON. CORROSION-RESISTANT SPRINKLER: A special service sprinkler with non-corrosive protective coatings, or that is fabricated from non-corrosive material, for use in atmospheres that would normally corrode sprinklers. DRY SPRINKLER: A special-service sprinkler intended for installation on dry pipe systems or wet pipe systems where the sprinkler is subject to freezing temperatures. The unit consists of a sprinkler permanently secured to an extension nipple with a sealed inlet end to prevent water from entering the nipple until the sprinkler operates. The unit MUST be installed in a tee fitting. Dry upright sprinklers are marked with the "B" dimension [distance from the face of the fitting (tee) to the top of the deflector]. Dry pendent and sidewall sprinklers are marked with the "A" dimension [the distance from the face of fitting (tee) to the finished surface of the ceiling or wall]. LARGE DROP SPRINKLER: A type of special application sprinkler used to provide fire control of specific high-challenge fire haz- ards. Large drop sprinklers are designed to produce an umbrella-shaped spray pattern downward with a higher percentage of "large" water droplets than standard spray sprinklers. The sprinkler has an extra-large orifice with a nominal K-Factor of 11.2. Marked "HIGH CHALLENGE" and "UPRIGHT". EARLY SUPPRESSION FAST-RESPONSE (ESFR) SPRINKLER: A sprinkler intended to provide fire suppression of specific high- challenge fire hazards through the use of a fast response fusible link, 14.0, 16.8, or 25.2 nominal K-Factor, and special deflector. ESFR sprinklers are designed to produce high-momentum water droplets in a hemispherical pattern below the deflector. This permits penetration of the fire plume and direct wetting of the burning fuel surface while cooling the atmosphere early in the development of a high-challenge fire. Marked "ESFR" and "UPRIGHT" or "PEND". INTERMEDIATE LEVEL/RACK STORAGE SPRINKLER: A standard spray sprinkler assembly designed to protect its operating element from the spray of sprinklers installed at higher elevations. The assembly consists of a standard or large orifice upright or pendent sprinkler with an integral upright or pendent water shield and guard assembly. Use only those sprinklers that have been tested and listed for use with the assembly. Refer to the technical data page for allowable sprinkler models. RESIDENTIAL SPRINKLER: A sprinkler intended for use in the following occupancies: one- and two-family dwellings with the fire protection sprinkler system installed in accordance with NFPA 13D; residential occupancies up to four stories in height with the fire protection system installed in accordance with NFPA 13R; and where allowed by the Authority Having Jurisdiction in resi- dential portions of any occupancy with the fire protection system installed in accordance with NFPA 13. Form No. F_080814 18.12.06 Rev 14.1.P65 Page 3 of 3 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Residential sprinklers have a unique distribution pattern and utilize a fast response" heat sensitive operating element. They en- hance survivability in the room of fire origin and are designed to provide a life safety environment for a minimum of ten minutes. For this reason, residential sprinklers must not be used to replace standard sprinklers unless tested for and approved by the Authority Having Jurisdiction. In addition to standard markings, the unit is identified as "RESIDENTIAL SPRINKLER" or "RES". INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION Refer to the appropriate sprinkler technical data page(s). INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. IMPORTANT: Always referto Bulletin Form No. F_091699 -Care and Handling of Sprinklers and the appropriate sprin- klergeneral care, installation, and maintenance guide. Viking sprinklers are to be installed in accordancewith the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards,wheneverapplicable. The sprinkler technical data page may contain installation requirements specific for the sprinkler model selected. The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. Form No. F_080814 18.12.06 Rev 14.1.P65 Replaces Form No. F_080814 Rev 14.1 (Added P65 Warning.) Page 1 of 4 N I 1(1 F"SPRINKLER GENERAL CARE, INSTALLATION, AND MAINTENANCE GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. DESCRIPTION - STANDARD RESPONSE, QUICK RESPONSE, EXTENDED COVERAGE, AND DRY SPRINKLERS Viking thermosensitive spray sprinklers consist of a small frame and either a glass bulb or a fusible operating element. Available styles include pendent, flush pendent, concealed pendent, upright, horizontal sidewall, vertical sidewall, or conventional, depending on the particular sprinkler model selected. Viking sprinklers are available with various finishes, temperature ratings, responses, and K-Factors to meet design requirementst. Used in conjunction with one of the corrosion-resistant coatings (for frame style sprinklers), the units provide protection against many corrosive environments. In addition, the special Polyester or PTFE coatings can be used in decorative applications where colors are desired. t Refer to the sprinkler technical data page for available styles, finishes, temperature ratings, responses, and nominal K-Factors for specific sprinkler models. LISTINGS AND APPROVALS Refer to the Approval Charts on the appropriate sprinkler technical data page(s) and/or approval agency listings. TECHNICAL DATA Specifications: WARNING: Cancer and Reproductive Harm- Refer to the appropriate sprinkler technical data sheet. • www.P65Warnings.ca.gov Material Standards: Refer to the appropriate sprinkler technical data sheet. INSTALLATION NOTE: Take care not to over-tighten the sprinkler and/or damage its operating parts! Maximum Torque: 1/2" NPT: 14 ft-lbs. (19.0 N-m) 3/4" NPT: 20 ft-lbs. (27.1 N-m) 1" NPT: 30 ft-lbs. (40.7 N-m) Care and Handling (also refer to Bulletin - Care and Handling of Sprinklers, Form No. F_091699.) Sprinklers must be handled with care. They must be stored in a cool, dry place in their original shipping container. Never install sprinklers that have been dropped, damaged, or exposed to temperatures exceeding the maximum ambient temperature al- lowed (refer to the temperature chart on the sprinkler technical data page). Never install any glass-bulb sprinkler if the bulb is cracked or if there is a loss of liquid from the bulb. A small air bubble should be present in the glass bulb. Any sprinkler with a loss of liquid from the glass bulb or damage to the fusible element should be destroyed immediately. (Note: Installing glass bulb sprinklers in direct sunlight (ultraviolet light) may affect the color of the dye used to color code the bulb. This color change does not affect the integrity of the bulb.) Sprinklers must be protected from mechanical damage during storage, transport, handling, and after installation. Sprinklers subject to mechanical damage must be protected with an approved sprinkler guard. Use only sprinklers listed as corrosion resistant when subject to corrosive environments. When installing corrosion-resistant sprin- klers, take care not to damage the corrosion-resistant coating. Use only the special wrench designed for installing coated or recessed Viking sprinklers (any other wrench may damage the unit). Concealed sprinklers must be installed in neutral or negative pressure plenums only! Use care when locating sprinklers near fixtures that can generate heat. Do not install sprinklers where they could be exposed to temperatures exceeding the maximum recommended ambient temperature for the temperature rating used. Wet pipe systems must be provided with adequate heat. Sprinklers supplied from dry systems in areas subject to freezing must be listed dry sprinklers, upright, or horizontal sidewall sprinklers installed so that water is not trapped. For dry systems, pendent sprinklers and sidewall sprinklers installed on return bends are permitted, where the sprinklers, return bend, and branch line piping are in an area maintained at or above 40 °F (4 °C). Installation Instructions - Standard Spray Sprinklers Viking sprinklers are manufactured and tested to meet the rigid requirements of approving agencies. They are designed to be installed in accordance with recognized installation standards. Deviation from the standards or any alteration to sprinklers or cover plate assemblies after they leave the factory including, but not limited to: painting, plating, coating, or modification, may render them inoperative and will automatically nullify the approvals and any guarantee made by The Viking Corporation. Form No. F_080614 18.10.11 Rev 16.1.P65 Replaces Form No. F_080614 Rev 16.1 (Added P65 Warning.) Page 2 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page. Before installation, be sure to have the appropriate sprinkler model and style, with the correct K-Factor, temperature rating, and response characteristics. Sprinklers must be installed after the piping is in place to prevent mechanical damage. Keep sprinklers with protective caps or bulb shields contained within the caps or shields during installation and testing, and any time the sprinkler is shipped or handled. la. For frame-style sprinklers, install escutcheon (if used), which is designed to thread onto the external threads of the sprinkler. Refer to the appropriate sprinkler data page to determine approved escutcheons for use with specific sprinkler models. lb. For flush and concealed style sprinklers: Cut the sprinkler nipple so that the 1/2' or 3/4" (15 mm or 20 mm)* NPT outlet of the reducing coupling is at the desired location, and centered in the opening* in the ceiling or wall. *Size depends on the sprinkler model used. Refer to the sprinkler technical data page. Apply a small amount of pipe-joint compound or tape to the external threads of the sprinkler only, taking care not to allow a build-up of compound in the sprinkler inlet. NOTE: Sprinklers with protective caps or bulb shields must have the caps or shields kept on them when applying pipe-joint compound or tape. Exception: For domed concealed sprinklers, remove the protective cap for installation, and then place it back on the sprinkler temporarily.. Refer to the appropriate sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. DO NOT use the deflector or fusible element to start or thread the sprinkler into a fitting. Install the sprinkler onto the piping using the special sprinkler wrench only, taking care not to over-tighten or damage the sprinkler. For flush and concealed style sprinklers: the internal diameter of the special sprinkler installation wrench is designed for use with the sprinkler contained in the protective cap. Exception: For domed concealed sprinklers, remove the protective cap for installation, and then place it back on the sprinkler temporarily. Thread the flush or concealed sprinkler into the %" or 3/4" (15 mm or 20 mm)* NPT outlet of the coupling by turning it clockwise with the special sprinkler wrench. *Thread size depends on the particular sprinkler model used. Refer to the sprinkler technical data page. C. Installation Instructions - Dry Sprinklers WARNING: Viking dry sprinklers are to be installed in the 1" outlet (for dry and preaction systems), or run of malleable, ductile iron, or Nibco CPVC* threaded tee fittings (for wet systems) that meet the dimensional requirements of ANSI B16.3 (Class 150), or cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125), even at branch line ends. The threaded end of the dry sprinkler is designed to allow the seal to penetrate and extend into the fitting to a predetermined depth. This prevents condensation from accumulating and freezing over the sprinkler seal. *NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-131. When selecting other CPVC fittings, contact Viking Technical Services. DO NOT install the dry sprinkler into a threaded elbow, coupling, or any other fitting that could interfere iith thread penetration. Such installation would damage the brass seal. DO NOT install dry sprinklers into couplings or fittings that would allow condensation to accumulate above the seal when the sprinkler is located in an area subject to freezing. NEVER try to modify dry sprinklers. They are manufactured for specific "A" or "B" dimensions and cannot be modified. The dry sprinkler must be installed after the piping is in place to prevent mechanical damage. Before installation, be sure to have the correct sprinkler model and style, with the appropriate 'A" or "B" dimension(s), temperature rating, orifice size, and response characteristics. Keep sprinklers with protective caps or bulb shields contained within the caps or shields during installation and testing, and any time the sprinkler is shipped or handled. Exception: For concealed and adjustable recessed dry sprinklers, the protective caps and shields are removed for installation. To install the dry sprinkler, refer to the instructions below and the appropriate sprinkler technical data page for illustrated instruc- tions. Dry upright sprinklers must be installed above the piping, in the upright position only. When installing dry upright or plain barrel style vertical sidewall sprinklers on piping located close to the ceiling, it may be necessary to lower the sprinkler into the fitting from above the ceiling. When installing dry upright or plain barrel vertical sidewall sprinklers from below the ceiling, verify that the opening in the ceiling is a minimum 1-1/2" (38.1 mm) in diameter. For thy upright or plain barrel vertical sidewall sprinklers in the upright position: First, install the escutcheon (if used) over the threaded end of the sprinkler barrel. Slide the escutcheon past the external threads. NOTE: When installing the dry upright or plain barrel vertical sidewall sprinkler from above the ceiling, it will be necessary to install the escutcheon after lowering the threaded end of the sprinkler through the ceiling penetration. A. For all dry sprinklers: Apply a small amount of pipe-joint compound or tape to the external threads of the sprinkler barrel only, taking care not to allow a build-up of compound or tape over the brass inlet and seal. NOTE: Sprinklers with protective caps or bulb shields must be contained within the caps or shields before applying pipe-joint compound or tape. Form No. F_080614 18.10.11 Rev 16.1.P65 Page 30f4 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Refer to the appropriate sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. Install the dry sprinkler on the piping using the special dry sprinkler wrench only, while taking care not to damage the sprinkler. NOTE: Thread the sprinkler into the fitting hand tight, plus 1/2 turn with the dry sprinkler wrench. For adjustable standard and adjustable recessed dry pendent and sidewall sprinklers: Escutcheons can be installed after the sprinklers have been installed onto the piping. Refer to the appropriate sprinkler technical data page for escutcheon installation instructions and illustrations. D. Installation Instructions - Testing 4. After installation, the entire sprinkler system must be tested. The test must be conducted to comply with the installation stand- ards. Viking high pressure sprinklers may be hydrostatically tested at a maximum of 300 psi (20.7 bar) for limited periods of time (two hours), for the purpose of acceptance by the Authority Having Jurisdiction. Make sure the sprinkler is properly tightened. If a thread leak occurs, normally the sprinkler must be removed, new pipe-joint compound or tape applied, and then reinstalled. This is due to the fact that when the joint seal is damaged, the sealing compound or tape is washed out of the joint. Air testing [do not exceed 40 psi (2.76 bar)] the sprinkler piping prior to testing with water may be considered in areas where leakage during testing must be prevented. Refer to the Installation Standards and the Authority Having Jurisdiction. Remove plastic protective sprinkler caps or bulb shields AFTER the wall or ceiling finish work is completed where the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operating ele- ments. To remove the bulb shields, simply pull the ends of the shields apart where they are snapped together. To remove caps from frame style sprinklers, turn the caps slightly and pull them off the sprinklers. SPRINKLER CAPS OR BULB SHIELDS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Retain a protective cap or shield in the spare sprinkler cabinet. 5. For flush style sprinklers: the ceiling ring can now be installed onto the sprinkler body. Align the ceiling ring with the sprinkler body and thread or push it on (depends on sprinkler model) until the outer flange touches the surface of the ceiling. Note the maximum adjustment is 1/4" (6.35 mm). DO NOT MODIFY THE UNIT. If necessary, re-cut the sprinkler drop nipple as required. 6. For concealed sprinklers: the cover assembly can now be attached. Remove the cover from the protective box, taking care not to damage the cover plate assembly. Gently place the base of the cover plate assembly over the sprinkler protruding through the opening in the ceiling. Push the cover plate assembly onto the sprinkler until the unfinished brass flange of the cover plate base (or the cover adapter, if used) touches the surface of the ceiling. Refer to the applicable technical data sheet to determin the maximum adjustment available for concealed sprinklers. DO NOT MODIFY THE UNIT. If necessary, re-cut the sprinkler drop nipple. NOTE: If it is necessary to remove the entire sprinkler unit, the system must be taken out of service. See section 6. INSPECTIONS, TESTS AND MAINTENANCE and follow all warnings and instructions. 5. OPERATION Refer to the appropriate sprinkler technical data page(s). During fire conditions, the operating element fuses or shatters (depending on the type of sprinkler), releasing the pip cap and sealing assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appro- priate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. The sprinkler technical data page may contain installation requirements specific for the sprinkler model selected. The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. Form No. F_080614 18.10.11 Rev 16.1.P65 Page 4 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. 6. INSPECTIONS, TESTS AND MAINTENANCE NOTICE: Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. NOTICE: The owner is responsible for having the fire-protection system and devices inspected, tested, and maintained in proper operating condition in accordance with this guide, and applicable NFPA standards. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. A. Sprinklers must be inspected on a regular basis for corrosion, mechanical damage, obstructions, paint, etc. Frequency of inspec- tions may vary due to corrosive atmospheres, water supplies, and activity around the sprinkler unit. B. Sprinklers or cover plate assemblies that have been field painted, caulked, or mechanically damaged must be replaced im- mediately. Sprinklers showing signs of corrosion shall be tested and/or replaced immediately as required. Installation standards require sprinklers to be tested and, if necessary, replaced after a specified term of service. Refer to NFPA 25 and the Authority Having Jurisdiction for the specified period of time after which testing and/or replacement is required. Never attempt to repair or reassemble a sprinkler. Sprinklers and cover assemblies that have operated cannot be reassembled or re-used, but must be replaced. When replacement is necessary, use only new sprinklers and cover assemblies with identical performance char- acteristics. C. The sprinkler discharge pattern is critical for proper fire protection. Therefore, nothing should be hung from, attached to, or otherwise obstruct the discharge pattern. All obstructions must be immediately removed or, if necessary, additional sprinklers installed. D. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ or valve instructions. Prior to removing the system from service, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected area. 1. Remove the system from service, drain all water, and relieve all pressure on the piping. For frame-style sprinklers, use the special sprinkler wrench to remove the old sprinkler by turning it counterclockwise to unthread it from the piping. For flush and concealed style sprinklers: Remove the ceiling ring or cover plate assem- bly before unthreading the sprinkler body from the piping. Ceiling rings and cover plates can be removed ei- ther by gently unthreading them or pulling them off the sprinkler body (depends on the sprinkler model used). After the ceiling ring or cover plate assembly has been removed from the sprinkler body, place the plastic protective cap (from the spare sprinkler cabinet) over the sprinkler to be removed and then fit the sprinkler wrench over the cap. Then use the wrench to unthread the sprinkler from the piping. Exception: Domed concealed sprinklers are removed without the plastic cap. 3. Install the new sprinkler unit by following the instructions in section 4. INSTALLATION. Care must be taken to ensure that the replacement sprinkler is the proper model and style, with the correct K-Factor, temperature rating, and response character- istics. A fully stocked spare sprinkler cabinet should be provided for this purpose. For flush or concealed sprinklers: stock of spare ceiling rings or cover plates should also be available in the spare sprinkler cabinet. E. Place the system back in service and secure all valves. Check for and repair all leaks. Sprinkler systems that have been sub- jected to a fire must be returned to service as soon as possible. The entire system must be inspected for damage, and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combustion or high ambient temperatures, but have not operated, should be replaced. Refer to the Authority Having Jurisdiction for minimum replacement requirements. 7. AVAILABILITY Viking sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F080614 18.10.11 Rev 16.1.P65 Replaces Form No. F_080614 Rev 16.1 (Added P65 Warning.) Page 1 of 1 N I I(JISIG® REGULATORY AND HEALTH WARNINGS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Regulatory and Health Warnings applying to materials used in the manufacture and construction of fire protection products are provided herin as they relate to legally mandated jurisdictional regions. A WARNING STATE OF CALIFORNIA, USA Installing or servicing fire protection products such as sprinklers, valves, piping etc. can expose you to chemicals including, but not li- mited to, lead, nickel, butadiene, titaninum dioxide, chromium, carbon black, and acrylonitrile which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov WARRANTY TERMS AND CONDITIONS For details of warranty, refer to Viking's current list price schedule at www.vikinggroupinc.com or contact Viking directly. Form No. F_111218 18.11.15 Rev 18.1 New Bulletin Worldwide www.tyco-fire.com tqC00 Contacts Series TYIFRB — 28,42,56, and 80 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described in herein are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers. They are designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls. The TY-FRB Recessed Pendent Sprin- kler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following Recessed Escutcheons: A two-piece Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) Recessed Escutcheon with 1/2 in. (12,7 mm) of recessed adjustment or up to 3/4 in. (19,1 mm) of total adjustment from the flush pendent position. A two-piece Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) Recessed Escutcheon with 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond what would be obtained when exposed IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 12 to corrosive atmospheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agen- cies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, con- centration of chemicals, and gas/ chemical velocity, should be consid- ered, as a minimum, along with the cor- rosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356. Sprinkler Guards are detailed in Technical Data Sheet TFP780. The Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main tam- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. NFPA 13 prohibits installation of 1/2 in. NPT sprinklers with K-factors greater than 5.6 in new construction. They are intended for retrofit in existing sprinkler systems only. DECEMBER 2020 '.'d... .-•-•:-'' I 11 1 I 4I - r t,7 ---- Sprinkler Identification Number (SIN) TY1131 . . . Upright 2.8K, 1/2 in. NPT 1Y1231.. Pendent 2.8K, 1/2 in. NPT TY2131 . . . Upright 4.2K, 1/2 in. NPT 1Y2231.. Pendent 4.2K, 1/2 in. NPT 1Y3131 . . . Upright 5.6K, 1/2 in. NPT TY3231.. Pendent 5.6K, 1/2 in. NPT 1Y4131 . . . Upright 8.0K, 3/4 in. NPT TY4231.. Pendent 8.0K, 3/4 in. NPT TY4831 . . . Upright 8.0K, 1/2 in. NPT 1Y4931.. Pendent 8.0K, 1/2 in. NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved See Tables A, B, C and D for complete approval information including corrosion- resistant status. Maximum Working Pressure See Table E TFPI7I 2-7/8" (73,0 mm) DIA. —] I I I 2-3/16' 1 (55,6 mm) 1/2 NPT** I WRENCH FLATS UPRIGHT PENDENT CROSS SECTION RECESSED PENDENT fi\ 7/16 I (11,1 mm) I NOMINAL '7 \. I MAKE-IN I T(521/4 mm) 1-9/16" (39,7 mm) STYLE 100r20 RECESSED ESCUTCHEON 2-3/16" (55,6 mm) (38,1 mm) I STYLE 100r20 H- 2-7/8" (73,0 mm) DIA. -H RECESSED PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION TFPI7I Page 2 of 12 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 7 - Bushing FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT ESCUTCHEON PLATE SEATING SURFACE * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector * 1/2' NPT* UPRIGHT 7/16" 11,1 mm) JOMINAL MAKE-IN I 2-3/16" (55,6 mm) I WRENCH FLATS FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 IN. NPT Discharge Coefficient K=2.8 GPM/psi"" (40,3 LPM/bar½) K=4.2 GPM/psi' (60,5 LPM/bar"") K=5.6 GPM/psi/2 (80,6 LPM/bar") K=8.0 GPM/psi"" (115,2 LPM/bar") Temperature Rating See Tables Aand B Finishes Sprinkler: See Table D Recessed Escutcheon: Signal or Pure White, Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ...................Copper/Bronze Bushing (K=2.8) ....................Bronze Poly-Stainless Physical Characteristics Frame ............................Bronze Button ................L316 Stainless Steel" Bulb...............................Glass Compression Screw .....L316 Stainless Steel" Deflector ...................Copper/Bronze Sealing Assembly. Gold Plated Beryllium Nickel w/TEFLON Type L316 stainless steel (UNS 31603) per ASTM A479/479M or BS EN 1008 WN1.4404. Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency, such as UL Listing based on the requirements of NFPA 13 and FM Approval based on the requirements of the FM Global Loss Prevention Data Sheets. Use only the style 10, 20, 30, or 40 Recessed Escutcheon, as applica- ble, for recessed pendent installations. 1/2 NPT* 1— 2-7/8' (73,0 mm) DIA. UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION 7/16' 1,1 mm) OMINAL AKE-IN 2-3/16' (55,6 mm) 2-3/16" (55,6 mm) 1-1/2 (38,1 mm) STYLE iC RECESSEu ESCUTCHEON TFPI7I Page 3 of 12 * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* ESCUTCHEON PLATE SEATING SURFACE 7/16 11,1 mm) 6 JOMINAL (55,6 mm) mm) MAKE-IN 1/72L 2-3/16 WRENCH STYLE 10 or 20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2 ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated \ SURFACE 4 - Bulb 6 - Deflector* on Deflector. POLY-STAINLESS FINISH ONLY FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 IN. NPT Installation The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 Nm). A leak tight 3/4 in. NPT sprinkler joint should be obtained with a torque of 10 to 20 lb-ft (13,4 to 26,8 Nm). Higher levels of torque can distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to com- pensate for insufficient adjustment in the escutcheon plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions: Step 1. Install pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1 to Figure 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench, see Figure 15. With reference to Figure 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step 3. After the ceiling is installed or the finish coat is applied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Recessed Pendent Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. 2-7/8" (73,0 mm) DlA. 2-7/8" (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION TFPI7I Page 4 of 12 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1/2 t (12,7 mm) I NOMINAL I MAKE-IN /J f (58,7 mm) I 2-1/4 1-9/16" I (57,2 mm (39,7 mm) I 3/4" NPT** I WRENCH STYLE 300r 40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated \ SURFACE 4 - Bulb 6 - Deflector * on Deflector. CROSS SECTION UPRIGHT 1/2" NOMINAL 2-5/16" (12,7 mm) ____ I MAKE-IN (58,7 mm) 2-1/4' 1-9/16" I (57,2 mm) (39,7 mm) 1 _ Il/V STYLE 40 RECESSED PENDENT ESCUTCHEON POLY-STAINLESS FINISH ONLY FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 IN. NPT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw uc_ 7/16' r 3 - Sealing 6 - Deflector Assembly 4 - Bulb 1,1 mm) 2-1/4' NOMINAL (57,2 mm) Temperature rating is MAKE-IN 1-9/16'indicated on Deflector. 23/16 (55,6 mm) (39,7 mm) I 5 ** Pipe thread connections provided on special 6 * per ISO 7-1 can be 1/2" NPT** WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 112 IN. NPT TFPI7I Page 5 of 12 2-7/8 DIA. 5/8±1/4' (73,0 mm) I 3/4 (19,1 mm) (15 9±6,4 mm) 1/4' (6,4 mm) 2-1/4" DIA. / FACE OF (57,2 mm) MOUNTING FITTING 1/8" 1 / _____/ (3,2 mm) SPRINKLER R7jH PLATE MOUNTING SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) I 3/4'_(19,1mm) (15,9±6,4 mm) _ 2-1/4" DIA. I 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER L\ PLATE FITTING 1/8" __ - (3,2 mm) MOUNTING ____ t f SURFACE CLOSURE SERIES 1-1/4(31,8 mm) J 1YFRB 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. ( 1/2±1/8" 73,0 mm) I 1/2"(12,7mm) (12 7±3,2 mm) 2-1/4" DIA. 1/4' (6,4 mm) SPRINKLER PLATE / FACE OF 57,2 mm)1 MOUNTING FITTING 1/8' / (3,2mm) ,r I MOUNTING SUR FACE CLOSURE SERIES 1-5/16"(33,3rnm) TY-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 112 IN. NPT - 2-7/8" DIA. 1/2±1/8' (73,0 mm) 1/2"(12,7 mm) (12,7±3,2 mm) 2-1/4' DIA. 1/4" (6,4 mm) I I / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) P77. MOUNTING _ SURFACE SERIES 1-1/4"(31,8mm) CLOSURE TYFRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR,1/2 IN.NPT TFPI7I Page 6 of 12 2-7/8 DIA. 5/8±1/4' (73,0 mm) I (19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA 1/4" (6,4 mm) I / FACE OF (57,2 mm) I I _____ MOUNTING I PLATE FITTING SPRINKLER ' _____ (3,2 mm) //, _ MOUNTING SURFACE SERIES 1-1/4'(31,8 mm) t CLOSURE TY-FRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. (73,0 mm) I 3/4(19,1 mm) 5/8±1/4" I (15,9±6,4 mm) 2-1/4" DIA. I 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER c PLATE FITTING 1/8" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm)I TYFRB 13/16' (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS (END 'A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4' NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH - 2-7/8" DIA. - (73,0 mm) 1/2±1/8" 1/2(12,7mm) 02 7±3,2 mm) 2-1/4" DIA. I 1/4' (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING : 1/8" (3,2 mm) I MOUNTING SURFACE SERIES 1-1/4' (31,8 mmJ CLOSURE TYFRB 1(25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2(12,7mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) / (57,2 mm) 1 7 FACE OFF O MOUNTING SPRINKL 7) PLATE FITTING 1/8" I (3,2 mm) MOUNTI SURFAC CLOSURE SERIES 1- 5/16 (333 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI7I Page 7 of 12 Sprinkler Finish5 K-Factor Type Temperature Bu lColor b Liquid Natural Chrome Brass Plated Polyesterc 135°F (57°C) Orange 155°F (68°C) Red Pendent 175°F(79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 1,2,3,4 135°F (57°C) Orange 155°F(68°C) Red Upright (TY1131) 175°F (79°C) Yellow 2.8 200°F (93°C) Green 1/2 in. NPT 286°F (141°C) Blue 135°F (57°C) Orange Recessed Pendent 155 F(68 C) Red (TY1231)a Figure 6 175°F (79°C) Yellow 200°F(93°C) Green 1,2,4 135°F (57°C) Orange Recessed Pendent 155 F(68 C) Red (TY1231)b Figure 7 175°F (79°C) Yellow 200°F (93°C) I Green NOTES Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listed by underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed, the sprinklers are UL and C-UL Listed as corrosion-resistant sprinklers. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 K-FACTOR SPRINKLERS TFPI7I Page 8 of 12 Sprinkler Finish3 K-Factor Type Temperature Bulb Liquid Color Natural Brass I Chrome Plated F~rc 135°F (57°C) Orange 155°F(68°C) Red Pendent (TY2231) 175F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange 155°F (68°C) Red Upright (TY2131) 175°F (79°C) Yellow 200°F (93°C) Green 4.2 1/2 in. NPT 1,2 286°F (141°C) Blue 135°F (57°C) Orange Recessed Pendent 155°F (68°C) Red (TY2231)a Figure 8 175°F (79°C) Yellow 200°F (93°C) Green 135°F (57°C) Orange Recessed Pendent 155°F (68°C) Red (TY2231)b Figure 9 175°F (79°C) Yellow 200°F(93°C) Green NOTES Installed with Style 10(1/2 in. NPT) or Style 40(3/4 in. NPT) 3/4in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2 in. NPT) or Style 30(3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed, the sprinklers are UL and C-UL Listed as corrosion-resistant sprinklers. TABLE B LABORATORY LISTINGS AND APPROVALS FOR 4.2 K-FACTOR SPRINKLERS TFPI7I Page 9 of 12 K-Factor Type Temperature Bulb Liquid Sprinkler Finish8 NBatural romde Polyesterc PolyStainlessC Coated 135°F (57°C) Orange 155°F (68°C) Red (TY3231) 1,2,3,4,5,6,7 1,2 1,2,3,5 175-F (79-C) Yellow 200°F (93°C) Green 286°F(141°C) Blue 135°F (57°C) Orange 155°F (68°C) Red Upright (T331) 1, 2, 3, 5,6 1,2 1,2,3,5 175-F (79-C) Yellow 200°F(93°C) Green 5.6 286°F (141°C) Blue NPT 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY3231)a 1,2, 4, 5 1,2 N/Ad - 175°F (79°C) Yellow 200°F (93°C) Green Figure 10 286°F (141°C) Blue 135°F (57°C) Orange 155°F (68°C) Red Recessed (TY3231)b 1, 2, 3, 4, 5 N/A N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 11 286-F (141-C) Blue NOTES a. Installed with Style 10(1/2 in. NPT) or Style 40(3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Not available (N/A). Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06( as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE C LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS TFPI7I Page 10 of 12 Sprinkler Finish8 K-Factor Type Temperature Bulb Liquid Color Natural Brass I Chrome Plated I Polyester PoIyStainlessc Lead Coated 135°F (57°C) Orange 155°F (68°C) Red Pendent (TY4231) 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 1, 2, 3, 4, 5, 6, 7 1,2 1,2,5 135°F (57°C) Orange 155°F(68°C) Red Upright (TY4131) 175°F (79°C) Yellow 200-F (93-C) Green 8.0 3/4 in. Blue 286°F (141°C) NPT 135°F (57°C) Orange 155°F(68°C) Red Recessed Pendent (TY4231)a 1, 2, 5 1,2 N/Ad 175°F (79°C) Yellow 200°F (93°C) Green Figure 12 286°F (141°C) Blue 135°F (57°C) Orange 155°F(68°C) Red Recessed Pendent (TY4231)1 1, 2, 3, 5 N/A N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 13 286°F (141°C) Blue 135°F (57°C) Orange 155°F(68°C) Red Pendent (TY4931) 175°F (79°C) Yellow 200°F(93°C) Green 8.0 1/2 in. NPT 1,2,4,5,6 N/A 1,2,5 286°F (141°C) Blue 135°F (57°C) Orange 155°F(68°C) Red Upright (TY4831) 175-F (79-C) Yellow 200-F (93-C) Green 286°F (141°C) Blue NOTES Installed with Style 10(1/2 in. NPT) or Style 40(3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2 in. NPT) or Style 30(3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Not available (N/A). Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLED LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 11 of 12 Sprinkler Finish K-Factor Type Natural I Chrome I Brass Plated I Polyester Lead Coated Pendent (TY1231) and 2.8 Upright (TY1131) 1/2 in. 175 psi (12,1 bar) N/A2 NPT Recessed Pendent (TY1231) Pendent (TY2231) and 4.2 Upright (TY2131) 1/2 in. 175 psi (12,1 bar) N/A NPT Recessed Pendent(TY2231) Pendent (TY3231) and 5.6 1/2 in. Upright (1Y3131) 250 psi (17,2 bar) NPT or 175 psi (12,1 bar)' Recessed Pendent (TY3231) Pendent (TY4231) 175 psi 8.0 and Upright (1Y4131) (12,1 bar) 3/4 in. 175 psi (12,1 bar) NPT Recessed N/A Pendent(TY4231) 8.0 Pendent (TY4931) 175 psi 1/2 in. and 175 psi (12,1 bar) (12,1 bar) NPT Upright (TY4831) NOTES The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. Not available (N/A). TABLE MAXIMUM WORKING PRESSURE Care and Maintenance The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire pro- tection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be taken to avoid damage to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. For more information, see Installation section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associ- ation such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. For more informa- tion, see Installation section. Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resis- tant material of construction. There- after, annual inspections per NFPA 25 should suffice. Inspections of corro- sion-resistant sprinklers are recom- mended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprinkler condition and the long- term integrity of the corrosion-resistant material, which can be affected by the corrosive conditions present. FINISH 1 NATURAL BRASS - POLY-STAINLESS GREY 2 ALUMINUM (RAL9007)1 POLYESTER PURE WHITE - POLYESTER (RAL9010)2 SIGNAL WHITE - POLYESTER (RAL9003) JET BLACK - POLYESTER (RAL9005)3 7 LEAD COATED 9 I CHROME PLATED TFPI7I Page 12 of 12 PIN 57— MX— X— MX I I —] SIN SPRINKLER 330 2.8K UPRIGHT (1/2 in. NPT) TY1131 331 2.8K PENDENT (1/2 in. NPT) TY1231 340 4.2K UPRIGHT (1/2 in. NPT) TY2131 341 4.2K PENDENT (1/2 in. NPT) TY2231 370 5.6K UPRIGHT (1/2 in. NPT) TY3131 371 5.6K PENDENT (1/2 in. NPT) TY3231 390 8.0K UPRIGHT (3/4 in. NPT) TY4131 391 8.0K PENDENT (3/4 in. NPT) TY4231 360 8.0K UPRIGHT (1/2 in. NPT) TY4831 361 8.0K PENDENT (1/2 in. NPT) TY4931 TEMPERATURE RATINGS 135 135°F(57°C) 155 1 155°F(68°C) 175 I 175-F (79-C) 200 I 200°F (93°C) 286 I 286-F (141-C) NOTES Available only on TY3131, TY3231, TY4131, and TY4231 Eastern Hemisphere sales only. Available in only 2.8K, 4.2K, and 8.0K, 155°F (68°C) and 200°F (93°C); requires longer lead time to manufacture. TABLE F SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) temperature rating, (specify) finish or coating, P/N (specify from Table F) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 02020 Johnson Controls. All rights rosornod. All specifications and other information shown were current as of document revision date and are sublnct to change without notice. Johnson NATIONAL FIRE PROTECTION ASSOCIATION and NFPA urn rnglstornd trademarks of National Arc PrctccScn AsscciuIicn Controls TEFLON iso registnrnd trademark Of DUPOnt DEWALT GENERAL INFORMATION ANCHORS & FASTENERS GENERAL INFORMATION SECTION CONTENTS HANGERMATE® General Information.........................1 Material Specifications ................... 2 Rod Hanging Anchors Installation Specifications..............2 ________________________________________________________________________________ Performance Data ............................ 3 I PRODUCT I] ;ll Orderinq Information.......................5 Hangermate is an all steel threaded fastening system for suspending steel threaded rod vertically overhead in pipe hanging, fire protection, electrical conduit and cable-tray applications. They are available in versions which can be installed in a variety of base materials including steel purlins, bar joists and beams, wood frame columns and beams, as well as concrete ceilings, beams and columns. Steel threaded rods in 1/4" and 3/8' diameters can be vertically suspended with Hangermate (a 1/2" diameter size is also available for wood). They are also offered in a side mount style for lateral installation of 1/4" and 3/8" diameter steel threaded rods onto joists, columns and overhead members. For all steel and wood hangers, a Hangermate Socket Driver is recommended to provide proper installation with a drill screw gun. For concrete hangers, a powered impact tool with a clutch is recommended. STEEL HANGERMATE HANGERMATE WOOD HANGERMATE A pivot head version is also available for flexible connection angle and positioning of rod hangers. An acoustical ceiling eyelet version is also available for hanging wire or cable attachments. CONCRETE HANGERMATE Hanging Pipe and Sprinkler Systems • HVAC Ductwork and Strut Channels Suspending Conduit and Cable Trays • Suspended Ceilings ANCHOR MATERIALS Lighting Systems and Overhead Utilities • Mounting Security Equipment • Zinc Plated Carbon Steel IURES AND BINEIFITS ANCHOR SIZE RANGE (TYR) + Ease and speed of overhead installation • 1/4' to 3/8" for Steel + Lower in-place cost, when compared to beam clamps, lag bolts and dropins 1/4" to 1/2" for Wood + Steel and wood Hangermate can be installed with a drill screw gun 1/4" to 3/8" for Concrete (Threaded Coupler Heads) + Side mount versions available for steel and wood Hangermate THREAD VERSION + Socket drivers, pole tool and accessories to optimize ease of installation Unified Coarse Thread (UNC) APPROVALS A LISTINGS SUITABLE BASE MATERIALS FM Approvals (FM) - see listing for applicable sizes and types Steel Purlins and Beams Pipe Hangers components for automatic sprinkler systems - File No. JI 3015153 Wood and Timber Underwriters Laboratory (UL) - see listing for applicable sizes and types Concrete Members Pipe Hangers - File No. EX 1289 IGUIDE.1 i [i1 CSI Divisions: 03 16 00 - Concrete Anchors, 05 05 23 - Metal Fastenings and 06 05 23 - Wood, Plastic, and Composite Fastenings. Rod Hangers shall be Hangermate anchors as supplied by DEWALT, Towson, MD. Anchors shall be installed in accordance with published instruction and the Authority Having Jurisdiction. www.DEWALTcom ANCHORS & FASTENERS MATERIAL SPECIFICATIONS MATERIAL SPECIFICATIONS Component Component Material Screw Body Case hardened carbon steel Coupling (IJNC thread) / Eyelet Case hardened carbon steel Zinc Plating ASTM B633, SC1, Type Ill (Fe/Zn5) INSTALLATION SPECIFICATIONS Steel Hangermate Rod Coupler Size 1/4 3/8 Coupling Thread Size (tJNC) 1/4-20 3/8-16 Coupling Thread Depth (in.) 3/8 3/8 Coupling Height (in.) 3/4 3/4 Socket Driver Size (in.) 1/2 1/2 Note: the side mount couplings have full thread depth (through hea, Concrete Hangermate Rod Coupler Size 1/4" 3/8" ANSI Drill Bit (in.) 1/4 1/4 Overall Screw Shank Length 1-1/4 1-1/2 Anchor Thread Length (in.) 1-1/8 1-3/8 Coupler / Washing Height (in.) 27/64 9/16 Integral Washer O.D. (in.) 31/64 39/64 Coupling Thread Size (UNC) 1/4-20 3/8-16 Coupling Thread Depth (in.) 3/8 1/2 Socket Driver Size (in.) 3/8 1/2 Installation Guidelines Wood Hangermate Rod Coupler Size 1/4 3/8 1/2' Coupling Thread Size (JNC) 1/4-20 3/8-16 1/2-13 Coupling Thread Depth (in.) 3/8 3/8 3/8 Coupling Height (in.) 13/16 13/16 13/16 Socket Driver Size (in.) 5/8 5/8 5/8 Note: the side mount couplings have full thread depth (through head). 1. If pre-drilling is required (certain types of wood truss/wood joist and all concrete base materials), select the recommended drill bit type and diameter For Concrete Hangermate, drill a hole to the appropriate embedment depth, adding at least 1/4" to the drilling depth to prevent the tip of the fastener from running into the back of the anchor hole during installation. 2. Select the appropriate socket driver for the anchor size and type to be installed and mount into chuck of installation tool. Insert the Hangermate coupling into the socket driver, and install perpendicular to the base material surface. Drive the fastener with a smooth steady motion until the driver and coupling is seated against the surface of the base material. 3. Thread the appropriate diameter steel threaded rod or threaded bolt into the coupling. The threaded rod or bolt should fully engage the thread length of the coupling on a vertical mount fastener. The threaded rod or threaded portion of the bolt can pass through coupling of a side mount fastener. When installing Hangermate, eye ptotection should be worn as a safety precaution. For UL and/or FM listings for bangers Steel Hangermate should be installed with a retaining nut for parts that are packaged with a nut (see performance data and listings as applicable). Suggested drill speed for Steel Hangermate installations is 1200 to 1800 rpm. Steel Wood Concrete El Install with appropriate sized steel socket driver. Install with appropriate sized wood socket driver. Install with appropriate sized concrete socket driver (side and variable mount direction versions not pictured) (side and variable mount direction versions not pictured) (variable mount direction version not pictured) 1-800-4 DEWALT PERFORMANCE DATA ANCHORS & FASTENERS PERFORMANCE DATA Hanqermate for Steel - General Cat. No. SCMw Description Mount Direction Rod Coupler Size Driver If MI Thick. In. Max In. UL FM Thick. ~-,:,S-61 UL Thick. Max. Pipe Size FM Thick. Hangermate For Steel - Vertical PFM2231 000 1/4-20 1" #3 Vert. 1/4" PFM2201200 (Silver) 0.060 0.210 - - PFM2231100 1/4-20 xl" #3 Vert. 3/8" PFM2201200 (Silver) 0.060 0.210 4" 0.060" - - PFM22311 ON 1/4-20 x 1"#3/nut Vert. 3/8 PFM2201200 (Silver) 0.060 0.210 4" 0.125" 4" 0.105 PFM2231150 1/4-20 x 1-1/2 #5 Vert. 3/8" PFM2201200 (Silver) 0.125 0.500 4" 0.060" 4" 0.060" PFM223115N 1/4-20 x 1-1/2" #5/nut Vert. 3/8 PFM2201200 (Silver) 0.125 0.500 4" 0.125" 4" 0.105 PFM2231200 1/4-20 x 1-1/2 43 Vert. 3/8 PFM2201200 (Silver) 0.060 0.210 4" 0.060" - - PFM223120N 1/4-20 x 1-1/2 #3/nut Vert. 3/8 PFM2201200 (Silver) 0.060 0.210 4" 0.060" - - PFM2231250 1/4-20 x 2" #3 Vert. 3/8" PFM2201200 (Silver) 0.060 0.210 4" 0.125" Hangermate For Steel - Horizontal PFM2241100 1/4-20 xl" #3 Side 3/8" PFM2201200 (Silver) 0.060 0.210 - - PFM22411 ON 1/4-20 x 1" #3/nut Side 3/8" PFM2201200 (Silver) 0.060 0.210 4" 0.060" 4" 0.060 PFM2241150 1/4-20 x 1-1/2" #3 Side 3/8" PFM2201200 (Silver) 0.060 0.210 - - PFM224115N 1/4-20 x 1-1/2" #3/nut Side 3/8" PFM2201200 (Silver) 0.060 0.210 4" 0.060" 4" 0.060" PFM2241200 1/4-20 x 1-1/2" #5 Side 3/8" PFM2201200 (Silver) 0.125 0.500 - - PFM224120N 1/4-20x 1-1/2" #5/nut Side 1 3/8" 1 PFM2201200 (Silver) 0.125 0.500 4" 0.060" 4" 0.060 Hangermate Pivot For Steel - Angled Applications PFM2281150 1/4-20 xl" #3 Variable 3/8 PFM2201250 0.060 0.188 - - PFM2281200 12-20 x 1-3/4 #5 Variable 3/8 PFM2201250 0.125 0.500 - - PFM2281250 1/4-14x 1" #3 Variable 3/8 PFM2201250 0.060 0.188 - - Hangemiate For Steel - Acoustical Gelling Screw Eyelet PFM2231500 1/4-14 x 7/8" #2(3/16 eyelet) Variable - PFM2201350 0.060 0.105 - - - - PFM2231550 1/4-14x2#2 (3/16" eyelet) Variable - PFM2201350 0.060 0.105 - - - - Hanqermate for Steel - Ultimate Load Canacities when Installed in Steel Cat No. Screw Description Mount Direction Rod Coupler Size Steel Gauge I Thickness 1610.060 11w. I 1410.075 lbs. I 1210.105 lbs. I 11810.125 I 3/1610.187 lbs. I 11410.250 lbs. I 11210.500 lbs. Hangermate For Steel - Vertical PFM2231000 1/4-201" #3 Vertical 1/4 785 1,140 1,740 2,375 2,820 - - PFM2231100 1/4-20x 1" #3 Vertical 3/8 785 1,140 1,740 2,375 4,695 - - PFM22311ON 1/4-20 xl" #3/nut Vertical 3/8 3,435 4,025 4,280 4,690 5,810 - - PFM2231150 1/4 -20 x 1-1/2" #5 Vertical 3/8 - - - - 3,675 5,205 5,205 PEM223115N 1/4-20 x 1-1/2" #5/nut I Vertical 1 3/8 3,435 4,025 4,280 4,690 5,810 5,810 5,810 PFM2231200 1/4-20x 1-1/2" #3 Vertical 3/8 785 1,140 1,740 2,375 4,695 - - PFM223120N 1/4-20 x 1-1/2" #3/nut Vertical 3/8 1 3,435 4,025 4,280 4,690 4,695 - - PFM2231250 1/4-20x2"#3 Vertical 3/8 785 1,140 1,740 2,375 4,695 - - Hangennate For Steel - Horizontal PFM2241100 1/4-20x1"#3 Side 3/8 1,740 1,945 2,420 2,570 2,810 - - PFM22411ON 1/4-20x1" #3/nut Side 3/8 2,755 2,810 2,570 2,810 2,810 - - PFM2241150 1/4-20x 1-1/2" #3 Side 3/8 1,740 1,945 2,420 2,570 2,810 - - PFM224115N 1/4-20 x 1-1/2" #3/nut Side 3/8 2,755 2,810 2,570 2,810 2,810 - - PFM2241200 1/4-20x 1-1/2" #5 Side 3/8 - - - - 2,205 2,810 2,810 PFM224120N 1/4-20 x 1-1/2" #5/nut Side 3/8 2,755 2,810 2,570 2,810 2,810 2,810 2,810 Hangermate Pivot For Steel - Angled Applications PFM2281150 1/4-20 xl" #3 Variable 3/8 635 - Vert. (875 © 45") 635 -Vert. (875 © 45") 1,130- Vert. (875 @45") 1,130 - Veil. (875 © 45") 1,640 - Vert. (875 © 45°) - - PFM2281 200 12-20 x 1-3/4" #5 Variable 3/8 635 - Vert. (875 © 45°) 635 -Vert. (875 © 45") 1,130 - Veil. (875 @45") 1,130 - Vert. (875 © 45") 1,640 - Veil. (875 © 45°) 1,640 - Veil. (875 © 45") 1,640- Veil. (875 @45") PFM2281250 1/4-14 xl" #3 Variable 3/8 590 - Veil. (875 @45°) 590 - Veil. (875 @45°) 970 - Veil. (875 @45°) 970 - Veil. (875 @45") 1,640 - Veil. (875 @45") - - Hangermate For Steel - Acoustical Ceiling Screw Eyelet PFM2231 500 3/16 x 2" #2 Variable - 800 800 1,245 PFM2231550 3/16x3-1/4#2 Variable - 800 800 1,245 The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 3.0 or greater to determine the allowable working load. The strength of the threaded rod used with the Hangerniate anchors must be considered when determining the controlling toad capacity of the assembly. - www.DEWALTcom I ANCHORS & FASTENERS PERFORMANCE DATA Hangermate for Wood - Ultimate Load Capacities when Installed in Wood',' Cat. No. Screw Description fount ns Rod Coupler Size Driver # Load lbs* UL k. FM --pip, Size Max. Pipe Size Hangermate For Wood - Vertical PFM2251000 1/4 x 2" Vert. 1/4 PFM2201150 (Red) 1,510 - - PFM2251050 1/4" xl" Veil. 3/8" PFM2201150 (Red) 650 - - PFM2251100 1/4" x 2' Veil. 3/8" PFM2201150 (Red) 1,510 3" - PFM2251150 5/16" a 2-1/2' Veil. 3/8" PFM2201150 (Red) 2,670 4' 4" PFM2251200 1/4" x3" Veil. 3/8" PFM2201150 (Red) 2,075 3" - PFM2251250 1/4" x4" Veil. 3/8" PFM2201150 (Red) 2,075 3" - PFM2251300 5/16" x 2-1/2" Veil. 1/2" PFM2201150 (Red) 2,670 - - Hangermate For Wood - Horizontal PFM2261000 1/4" x " Side 1/4" PFM2201150 (Red) 650 - - PFM2261050 1/4" x " Side 3/8" PFM2201150 (Red) 650 - - PFM2261100 1/4" x 2" Side 3/8" PFM2201150 (Red) 1,800 3" - PFM2261150 5/16" x 2-1/2" Side 3/8" PFM2201150 (Red) 1,450 3" - Hangermate Pivot For Wood - Angled Applications PFM2281100 1/4" x2" Variable 3/8" PFM2201250 Hangermate For Wood - Acoustical Ceiling Screw Eyelet PFM2251500 3/16" x 3-1/4" Variable - PFM2201350 880 ldmale Loads In Douglas Fir, Pine and Spruce . Trussioisl manufacturers may require pre-drilled holes with wood depending on the location of the anchor installation. Consult with the truss/joist manufacturerfordetails, [2.The values listed above are ultimate load capacities that must be reduced by a minimum safety factor of 3.0 or greater to determine the allowable working load. Concrete Hangermate - Ultimate Load Capacities when Installed in Normal-Weight Concrete'-'.' Minimum Concrete Compressive Strength (F c) Cat No. Rod Coupler Size In. Screw Description Mount Direction ANSI Drill Bit Diameter In. Embed. Depth In. 2,000 psi I 4,000 psi i I 6,000 psi Tension I Shear I Tension I Shear I Tension I Shear lbs. I lbs. I lbs. His. I His. I lbs. PFM2217171 1/4 1/4" x 1-1/4" Vertical 1/4 1-1/4 1,390 1,810 1,950 2,440 I 2,070 I 2,570 PFM2217173 3/8 1/4" x 1-1/2" 1 Vertical 1/4 1-1/2 1,760 2,580 2,595 2,640 2,770 2,700 The values listed above are ultimate load capacities for anchors installed in uncracked normal weight concrete. The values listed above are ultimate toad capacities which must be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. linear interpolation may be used to determine load capacities for intermediate compressive strengths. Concrete Hangermate - Ultimate Load Capacities when Installed Through Metal Deck into Lightweight Concrete'-'A' Ughtweight Concrete Over Metal Deck fc ~ 3,000 psi Cat No. Rod Coupler Size In. Screw Description Mount Direction ANSI Drill Bit Diameter In. Embedment Depth In. 4-1/2" de Deck Tension I Load at 45 lbs. I lbs. PFM2217171 1/4 1/4" x 1-1/4" Vertical 1/4 1-1/4 800 1,140 PFM2217173 1 3/8 1/4"X -1-1/2" 1 Vertical 1/4 1-1/2 1,780 1,500 1, The values listed above are ultimate load capacities for anchors installed .n uncracked sand-lightweight concrete. The metal deck shall not exceed 18 gauge (0.048-inch base metal thickness) and conform to ASTtv1 A 653. The values listed above are ultimate load capacities which must be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. The tabulated load values are for anchors installed with a minimum lower flute edge distance of 1-1/8-inch; or in the upper flute with consideration for integral washer clearance. Concrete Hangermate - Ultimate Load Capacities when Installed In Hollow Core Concrete Plank'.' Cat No. Rod Coupler Size I Screw Description I Mount Direction I ANSI Drill Bit Diameter I meter I Embedment Depth I Tension, I Center of Web I Tension, I Center of Cure in. I in. I in. lbs. I lbs. PFM2217171 1/4 1/4" x 1-1/4" Vertical 1/4 1-1/4 2,775 I 1,920 PFM2217173 3/8 1/4" x 1-1/2" Vertical 1/4 1-1/2 3,700 2,570 Tabulated load values are for anchors installed in 8-inch-thick uncracked hollow core concrete with minimum compressive strength of 5,000 psi at the time of installation. The normal-weight concrete must have 1-1/2" cover above and below cores and a minimum web thickness 011-1/2". The values listed above are ultimate load capacities which must be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. Concrete Hangermate - Factory Mutual (FM Global) Listings for Pipe Hangers Cat No. Rod Coupler Size I Screw Description I Mount Direction I ANSI Drill Bit I Diameter I Embedment Depth I FM Max. In. I in. I in. I Pipe Size I PFM2217173 3/8 I 1/4" x 1-1/2" Vertical 1/4 I 1-1/2 1-800-4 DEWALT ORDERING INFORMATION ORDERING INFORMATION Hanuermate for Steel - Vertical Cat. No. Description Driver # (Silver) Mount Rod Size Box Qty. Carton Qty. PFM2231 000 1/4-20 x " #3 PFM2201200 Vertical 1/4" 25 125 PFM2231100 1/4-20 x " #3 PFM2201200 Vertical 3/8' 25 125 PFM22311ON 1/4-20 xl' #3/nut PFM2201200 Vertical 3/8 25 125 PFM2231150 1/4-20 x 1-1/2 #5 PFM2201200 Vertical 3/8" 25 125 PFM223115N 1/4-20 x 1-1/2" #5/nut PFM2201200 Vertical 3/8" 25 125 PFM2231200 1/4-20 x 1-1/2" #3 PFM2201200 Vertical 3/8' 25 125 PFM223120N 1/4-20x1-1/2" #3/nut PFM2201200 Vertical 3/8' 25 125 PFM2231250 1/4-20 x 2' #3 PFM2201200 Vertical 3/8" 25 125 Hanaermate for Steel - Horizontal Cat. No. Description Driver # (Silver) Mount Rod Size Box Qty. Carton Qty. PFM2241100 1/4-20 x 1" #3 PFM2201 200 Side 3/8" 25 125 PFM22411ON 1/4-20x 1" #3/nut PFM2201200 Side 3/8" 25 125 PFM2241150 1/4-20 x 1-1/2" #3 PFM2201200 Side 3/8" 25 125 PFM224115N 1/4-20x 1-1/2" #3/nut PFM2201200 Side 3/8" 25 125 PFM2241200 1/4-20x 1-1/2" #5 PFM2201200 Side 3/8" 25 125 PFM224120N 1/4-20 x 1-1/2" #5/nut PFM2201200 Side 3/8' 25 125 Hanaermate Pivot for Steel - Analod Annlicatinns Cat. No. Description Pivot Driver # Mount Rod Size Box (fly. Carton (fly. PFM2281150 1/4-20x 1" #3 PFM2201250 Variable 3/8" 25 125 PFM2281 200 12-20 x 1-3/4" #5 PFM2201250 Variable 3/8" 25 125 PFM2281250 1/4-14 xl" #3 PFM2201250 Variable 3/8" 25 125 m Hanaermate Acoustical Ceilina Eyelet for Steel Cat. No. Description Eyelet Driver # Mount Eyelet Hole Box (fly. Carton (fly. PFM2231 500 3 /16" x 2" 1/4-14 x_7/8"_#2_screw PFM2201350 Variable 3/16" 25 125 PFM2231550 3/16"x3-1/4" 1/4-14x 2' #2 screw PFM2201350 Variable 3/16" 25 125 Hanuermate for Wood - Vertical Cat No Description Driver # (Red) Mount Rod Size Box (fly. Carton my. PFM2251000 1/4" x 2" PFM2201150 Vertical 1/4 25 125 PFM2251050 1/4" xl" PFM2201150 Vertical 3/8" 25 125 PFM2251100 1/4" x2" PFM2201150 Vertical 3/8" 25 125 PFM2251150 5/16"x2-1/2" PFM2201150 Vertical 3/8" 25 125 PFM2251200 1/4 x3" PFM2201150 Vertical 3/8" 25 125 PFM2251250 1/4" x 4" PFM2201150 Vertical 3/8" 25 125 PFM2251300 5/16 x 2-1/2' PFM2201150 Vertical 1/2" 25 125 Hanaermate for Wood - Horizontal Cat No. Description Driver # (Red) Mount Rod Size Box my. Carton my. PFM2261000 1/4' x " PFM2201150 Side 1/4' 25 125 PFM2261050 1/4' x " PFM2201150 Side 3/8' 25 125 PFM2261100 1/4" x 2" PFM2201150 Side 3/8" 25 125 PFM2261150 5/16 x 2-1/2" PFM2201150 Side 3/8 25 125 Hanaermate Pivot for Wood - Analed Annlicatinns Cat No. Description Pivot Driver # Mount Rod Size Box y. Carton Wy. PFM2281100 1/4" x 2" PFM2201250 Variable 3/8 25 1 125 Hanuermate Acoustical Ceilina Eyelet for Wood Cat No. Description I Eyelet Driver # Mount Eyelet Hole Box (fly. 3/16' x 3-1/4" Carton Qty. PFM2251500 PFM2201350 Variable 3/16" 25 1 125 ANCHORS & FASTENERS www.DEWALTcom ORDERING INFORMATION ANCHORS & FASTENERS Hanuermate for Concrete - Vertical Cat. No. Description Driver # (Black) Mount Rod Size J Box Qty. Carton lily. PFM2217171 1/4 x 1-1/4 PFM1491050 Vertical 1/4" 100 600 PFM2217173 1/4 x 1-1/2 PFM1491100 Vertical 3/8" 100 600 1. Concrete Hangermate require a pie-drilled hole using a 1/4 ANSI carbide drill bit (e.g. DW5517). Hangermate Pivot for Concrete - Angled Applications',' Cat. No. Description Pivot Driver # Mount Rod Size Box Qty. Carton Oty. PFM2281300 3/16" x2" PFM2201250 Variable 3/8 25 125 The Hangermate Pivot for concrete require a pre-drilled hole using a 3/16" ANSI carbide drill bit (e.g. DW5402). IJl1tmale load capacity for the Hangermate Pivot for concrete is 875 lbs. The ultimate load capacities must be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. Concrete Installation Accessories and Tool Guide Drilling installation Description Rotary Hammer SDS+ Bit Max Torque (ft-lb.) impact Driver or _Wrench Impact-Rated Socket I Driver # Cat No. cl PFM221 7171 4 1" V 1/4" DCH273P2DH 0W5416 0W5517 (1/4 150 DCF887 (1/4__ Impact Driver) PFM1491050 or DWMT1 7311 DCF890 (3/8__Impact Wrench) DW2284 (3/8) PFM221 7173 3 /8 Vertical Hanger DCH273P2DH DW5416 DW5517 (1/4 150 0CF887 (1/4__ Impact Driver) PFM1491100or DWMT1 7311 DCF890 (3/8__Impact Wrench) 0W2286 (1/2) Steel and Wood Hanoermate Pole Tool Cat. No. Description Std. Pack lily. Carton Oty. PFM2201100 Hangermate Pole Tool (Kit) 1 5 The Hangermate pole tool kit is designed for use with standard 1/2 steel conduit tubing (conduit not included) and can be customized to various lengths and ceiling heights. Compatible with standard steel and wood Hangermate. Steel and Wood Hanaermate Pole Tool Cat No. Description Std.Pack lily. CartonQty. PFM2201200 1/4 & 3/8 Steel Hangermate Driver - Vertical _and _Horizontal _Mounts _(Silver) 5 25 PFM2201150 1/4 & 3/8 Wood Hangermate Driver - Vertical and Horizontal _Mounts _(Re 5 25 PFM1491050 1/4 Concrete Hangermate Driver - Vertical Mount (Black) 5 25 PFM1 491100 3/8 Concrete Hangermate Driver - Vertical Mount (Black) 5 25 PFM2201250 Hangermate Pivot Driver - Angled Mounts 5 25 PFM2201350 Hangermate Eyelet Driver - Angled Mounts 5 25 All Hangermate drivers have a 1/4-inch hex for connection to tools. Universal Installation Accessories Cat. No. Description Std.Pack Qty. Carton (ft. PFM2201050 3/8 to 1/2 Adapter 25 125 The 3/8 to 1/2 adaptor has a 3/8-16 external thread and a 1/2-13 internal thread. rTT] 1-800-4DEWALT 1/2" through 1" pipe 1 1/4' through 2" pipe FIG. 69: DIMENSIONS (IN) • LOADS_(LBS) • WEIGHT_(LBS) Pipe Size Max Load Weight A Rod Size B C F G Width 1/2 300 0.10 /8 2/8 2 19A6 11/8 3/4 0.10 2/4 1/8 15A6 1 0.10 29A6 111A6 1 11/4 0.10 2/8 1/4 1/8 1/8 11/2 0.10 2/4 0.11 31/4 2/8 2% 525 0.20 4 2/4 15A6 3/4 3% 3 0.20 313/i6 215416 13A6 4 650 0.30 411A6 313A6 19A6 4/8 5 1,000 0.54 1/2 55A6 6 0.65 611A6 59A6 21/4 8 1.00 89A6 79A6 'II ®s LISTED APPROVED 21/2 through 8" pipe 21/2 through 8" Size ;1 I [e [r] 4 Fig. 69 (Formerly Afcon Fig. 300) Adjustable Swivel Ring, Tapped Per NFPA Standards Size Range: 1/2" through 8" Material: Carbon steel Finish: Strap is Pre-Galvanized Zinc Material. Nut is Zinc Plated. Service: Recommended for suspension of non-insulated stationary pipe line. Maximum Temperature: 450 F Approvals: Complies with Federal Specification A-A-1192A (Type 10), WW-H-171-E (Type 10), and ANSI/MSS SP-58 (Type 10). UL Listed and FM Approved (Sizes '/4"- 8"). Features: 1/2" - 2" sizes designed for use with steel and CPVC piping and manufactured with FBC System Compatible oil. Threads are countersunk so that they cannot become burred or damaged. Knurled swivel nut provides vertical adjustment after piping is in place. Captured swivel nut in the 1/2' through 6" sizes. The capture is permanent in the bottom portion of the band, allowing the hanger to be opened during installation if desired, but not allowing the nut to fall completely out. Ordering: Specify size, figure number and name. Non-captured nut also available upon request. ' 4 1/2" through 2" Size Rounded Edge Design PROJECT INFORMATION APPROVAL STAMP Project: [-]Approved Address: []Approved as noted Contractor: []Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: U c us LISTED 417,con. SEISMIC RESTRAINTS Fig. AF310 (Formerly Afcon Fig. 310) Surge Restrainer Size Range: 1" thru 2" Figure 69, Swivel Ring Hanger Material: Carbon steel Finish: Pre-Galvanized per ASTM A653 Restrainer Service: Prevents vertical movement of horizontal sprinkler piping from thrust loads due to sprinkler activation. The surge restrainer is intended to be installed with Anvil's Figure 69 Swivel Ring Hanger. Restraint Service: May be installed as part of a branch line seismic restraint assembly per the requirements of NFPA 13. The surge restrainer is intended to be installed with Anvil's Figure 69 Swivel Ring Hanger. Approvals: cULus Listed (UL 203 and UL 203a). Complies with the hanging and restraint requirements listed in NFPA 13. Features: One universal size accommodates Fig. 69 sizes 1" through 2' Simple design allows for quick installation on existing sprinkler systems. Installation Instructions: Snap surge restrainer onto the Fig. 69 knurl nut. The gap between the surge restrainer and service pipe shall not exceed 1/8 Fire Protection applications shall also be installed per the requirements of NFPA 13. Ordering: Specify figure number and description. EM /8" Rod Fig. AF31O —Fig. 69 Knurl Nut Fig. 69 Branch Pipe Surge Restraint Seismic Restraint Assembly Assembly FIG. AF310: LOADS (LBS) • DIMENSIONS (IN) • WEIGHT (LBS) Service Rod UL Max Seismic Restraint Load Approx. Pipe Size Size ([IL 203a) Weight/100 1 thru 2 /8 300 4 Notes: Anvil Internationat® brand bracing components are designed to be compatible ONLY with other Anvil International® brand bracing components, resulting in a Listed seismic bracing assembly. Updated UL listing information may be viewed at www.ul.com Disclaimer: Anvil International ("Anvil") does not provide any warranties and specifically disclaims any liability whatsoever with respect to Anvil bracing products and components that are used in combination with products, parts or systems not manufactured or sold by Anvil. In no event shall Anvil be liable for any incidental, direct, consequential, special or indirect damages or lost profits where non-Anvil bracing components have been, or are used. PROJECT INFORMATION APPROVAL STAMP Project: 0 Approved Address: J Approved as noted Contractor: J Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.18