HomeMy WebLinkAbout1 LEGOLAND DR; ; FPC2020-02021:1I:I11II]i t~r'city of Carlsbad Print Date: 07/17/2024 Job Address: 1 LEGOLAND DR, CARLSBAD, CA 92008-4610 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2111000900 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2020-0202 Status: Closed - Finaled Applied: 11/23/2020 Issued: 12/09/2020 Finaled Close Out: 07/17/2024 Final Inspection: INSPECTOR: Cheung, Nathaniel Salcedo, Felix Project Title: Description: LEGOLAND -PROVIDE FIRE ALARM FOR ELECTRICAL CLOSETS FOR 6 RIDES (ADDRESSABLE, 5 (OF EACH) CONTROL PANELS, PUI STATIONS, CELL. TRANSMITTERS, DOCUMENT STORAGE CABINETS, & 21 DEVICES) Applicant: FPContractor: PYRO-COMM SYSTEMS INC PYRO-COMM SYSTEMS INC CHARLES KRETZING 15215 ALTON PKWY, # STE 200 5115 AVENIDA ENCINAS, #G IRVINE, CA 92618-2613 CARLSBAD, CA 92008-4387 (714) 902-8000 (760) 930-6014 FEE AMOUNT FIRE Reinspection (per inspection) $193.00 FIRE Sprinkler Monitoring $2,298.00 Total Fees: $2,491.00 Total Payments To Date: $2,491.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Pyro-Comm Systems, Inc. 5115 AVENIDA ENCINAS CARLSBAD, CA 92008 (760) 930-6014 - FAx (760) 930-6015 Si Legoland FACP Ride Adds I Legoland Dr. Carlsbad, CA 92008 Fire Alarm System Submittal PCSI Job# 2020388/2020390 FIRE ALARM SYSTEM MFG. MODEL# DESCRIPTION CSFM# [CONTROL PANELS] NOTIFIER NFW-50X Fire Alarm Control Panel 7165-0028:0505 NOTIFIER FCM-1 Control Module 7300-0028:0219 [AUXILIARY POWER SUPPLIES] NOTIFIER FCPS-24S8 8.0 Amp Sync. Aux. Power Supply 7315-0028:0225 [BATTERIES] NOTIFIER BAT-1270 Battery-7 AH N/A [DIALER PANELS] TELGUARD TG7-FS Cellular Alarm Communicator 7300-1402:0109 [DETECTORS] NOTIFIER FSP-95 1 Low-Profile Intelligent Smoke Det. 7272-0028:0503 NOTIFIER B300-6 Flanged Mounting Base 7300-1653:0109 NOTIFIER NP-200 Addressable Photoelectric Detector 7272-0028:0503 [MANUAL PULL STATIONS] NOTIFIER NOT-BG12LX Address Manual Pull Station 7150-0028:0199 [SIGNALING DEVICES] SYST.SENSR. P2RK Wall Horn/Strobe Weatherproof-Red 7125-1653:0188 [MISC] SPACE AGE 55U00685 Document Storage Box N/A WWW.PYROCOMM.COM C-10 612153 CORPORATE OFFICE • 15531 CONTAINER LANE • HUNTINGTON BEACH, CA 92649 (714) 902-8000 NORTHERN CA REGIONAL OFFICE - 10966 BIGGE STREET • SAN LEANDRO, CA 94577 (510)632-1208 NOTIFIER® by Honeywell LNFW-50X)Intelligent Addressable FACP with Communicator General The FireWarden-50X (NFW-50X) is the latest intelligent address- able fire alarm control panel (FACP) within the FireWarden Series and is a direct replacement for the FireWarden-50 (NFW-50). The NFW-50X comes with a pre-installed communicator and supports up to 50 addressable devices in any combination of detectors or mod- ules. With an extensive list of powerful features, the NFW-50X pro- grams just like FireWarden-100 products, yet fits into applications previously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL-MOD or CELL-CAB-N. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTM). Features Listed to UL Standard 864, 10th edition Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator Optional CELL-MOD or CELL-CAB-N GSM Central Station Com- municator over AlarmNet® Compatible with SWIFT® wireless devices Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address Two independently programmable, built-in Style Z (Class A) or Style V (Class B) NAC circuits Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices Notification Appliance Circuit End of Line resistor matching Four programmable function keys for ease of maintenance Two programmable relays and one fixed trouble relay Built-in Programmer Integral 80-character LCD display with backlighting Real-time clock/calendar with automatic daylight savings control History file with 1,000 event capacity Addressable sounder base Control module delay timer Automatic detector sensitivity testing (NFPA 72 compliant) Automatic device type-code verification Point trouble identification Waterfiow selection per module point Alarm verification selection per detector point Maintenance alert warns when smoke detector dust accumula- tion is excessive One-person audible or silent walktest with walktest log & printout System alarm verification selection per detector point PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant) Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator Upload/Download of program and data via USB with optional FS- Tools Programming Utility SLC COMMUNICATION LOOP Supports FlashScan® and CLIP protocols SLC operates up to 10,000 ft. (3,000 m) in FlashScan mode with twisted, unshielded wire Single addressable SLC loop which meets NFPA Class B and Class A requirements 50 addressable device capacity (any combination of addressable detectors and modules) Compatible with NOTIFIER FireWarden & ONYX Series address- able devices (refer to the FireWarden SLC Wiring Manual) NOTIFICATION APPLIANCE CIRCUITS (NA CS) Two independently programmable output circuits. Circuits can be configured for the following outputs: - Style V (Class B) - Style Z (Class A) Silence Inhibit and Autosilence timer options Continuous, March Time, Temporal, or California code for main circuit board NACs with two-stage capability Selectable strobe synchronization per NAC 2.5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A PROGRAMMING AND SOFTWARE Autoprogramming (learn mode) reduces installation time Custom English labels (per point) may be manually entered or selected from an internal library file Two programmable Form-C relay outputs 50 software zones Continuous fire protection during online programming DN-60955:C • 7/16/2018 - Page 1 of 4 Program Check automatically catches common errors not linked to any zone or input point OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows®-based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS-Tools is available on www.notifier.com. User interface LED INDICATORS Fire Alarm (red) • CO Alarm (red) AC Power (green) • Supervisory (yellow) Trouble (yellow) • Ground fault (yellow) Battery fault (yellow) • Disabled (yellow) Maintenance (yellow) • Communication (yellow) Alarm Silenced (yellow) • F1-F4 Programmable Function Keys (yellow) KEYPAD 16 key alpha-numeric pad Acknowledge Alarm Silence Drill (Manual Evacuate) Four (4) programmable function keys• Reset (lamp test) Product Line Information (NFW-5OXAddressable Fire Alarm Control Panel with one SLC Ióiiludes main circuit board with display, pre-install'iPOi (coM communicator, chassis with transformer, backbox with door, plastic bag containing screws, cables, key, etc. FS-Tools: Programming software for Windows®-based PC com- puter. Available for download at www.notifier.com. CELL-CAB-N/CELL-MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES-R: Optional dress panel for the NFW-50XR (red). DP-ES-B: Optional dress panel for NFW-50X (black). TR-CE-B: Optional trim ring for semi-flush mounting. (Black. For red, order TR-CE.) BB-XP: Optional cabinet for one or two modules. Optional cabinet for up to six modules mounted on CHS-6 chassis. Battery backbox, holds up to two 25 AH batteries & CHG-75. NFS-LBB: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-25 cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional NFS-LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than I8AH. BAT Series: Batteries, see data sheet DN-6933. PRN Series: UL listed compatible event printer. Uses tractor-fed paper. OPTIONAL MODULES 4XTM Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. COMPATIBLE ANNUNCIATORS N-ANN-SO: Remote, black LCD annunciator mimics the information displayed on the FACP LCD display. Recommended wire type is un- shielded. N-ANN-100: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. (Basic model is black; order R for red.) N-ANN-I/O: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DN-7105.) N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DN-60242.) N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242.) N-ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DN-71 07.) N-ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DN-7103.) ADDRESSABLE DEVICES FSP-951: Addressable low-profile photoelectric smoke detector. FlashScan only. FSP-951-IV: Addressable low-profile photoelectric smoke detector. Ivory. FlashScan and CLIP mode. NP-200: Addressable low-profile photoelectric smoke detector. B300-6 base included, FlashScan only. NP-200-IV: Addressable low-profile photoelectric smoke detector. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951T: Addressable low-profile photoelectric smoke detector with thermal sensor. FlashScan only. FSP-951T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory. FlashScan and CLIP mode. NP-200T: Addressable low-profile photoelectric smoke detector with thermal sensor. B300-6 base included. FlashScan only. NP-200T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951 R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. FSP-951 R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. FlashScan and CLIP mode. NP-200R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. NP-200R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory, FlashS- can and CLIP mode. FST-951: Low-profile 135°F fixed thermal sensor. FlashScan only. FST-951-IV: Low-profile 135°F fixed thermal sensor. Ivory. FlashS- can and CLIP mode. NH-200: Low-profile 135°F fixed thermal sensor. B300-6 base included, FlashScan only. NH-200-IV: Low-profile 135°F fixed thermal sensor. Ivory. B300-6-IV base included, FlashScan and CLIP mode. FST-951R: Low-profile, intelligent, rate-of-rise thermal sensor. FlashScan only. FST-951R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. FlashScan and CLIP mode. NH-200R: Low-profile 135°F fixed thermal sensor. B300-6 base included, FlashScan only. NH-200R-IV: Low-profile 135°F fixed thermal sensor. Ivory. B300-6- IV base included, FlashScan and CLIP mode. FST-951H: Low-profile intelligent 190°F/88°C fixed thermal sensor. FlashScan only. FST-951H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- sor. Ivory. FlashScan and CLIP mode. NH-200H: Low-profile intelligent 190°F/88°C fixed thermal sensor. B300-6 base included, FlashScan only. Page 2 of 4— DN-60955:C • 7/16/2018 NH-200H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- sor. Ivory. B300-6-IV base included, FlashScan and CLIP mode. Legacy Devices FSP-851: Addressable low-profile photoelectric smoke detector. NP-100: Addressable low-profile photoelectric smoke detector. FSP-8511: Addressable low-profile photoelectric smoke detector with thermal sensor. NP-1 OCT: Addressable low-profile photoelectric smoke detector with thermal sensor. FSP-851R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. NP-100R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FST-851: Fast-response, low-profile heat detector. NH-100: Fast-response, low-profile heat detector. FST-851 R: Fast-response, low-profile heat detector with rate-of-rise option. NH-I OOR: Fast-response, low-profile heat detector with rate-of-rise option. FST-851 H: Fast-response, low-profile heat detector that activates at I90°F188°C. NH-I00H: Fast-response, low-profile heat detector that activates at I90°F188°C. FAPT-851: Addressable low-profile multi-sensor detector. NP-Al 00: Addressable low-profile multi-sensor detector. B200S: Programmable, addressable sounder base. B200SR: Addressable sounder base. DNR: InnovairFIex low-flow non-relay duct-detector housing. (Order FSP-851R, FSP-951R, or NP-I00R separately.) DNRW: InnovairFIex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order FSP-851R, FSP-951R, or NP-I OUR separately.) Addressable Modules FMM-I: Addressable Monitor Module for one zone of normally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NMM-I00: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0 (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. FDM-I: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only lDCs. NDM-I00: Dual Monitor Module. Same as NMM-100 except it pro- vides two Style B (Class B) only lDCs. FMM-101: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NMM-IOOP: Miniature version of NMM-IOO. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. FZM-I: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. NZM-100: Similar to NMM-1 00. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. FCM-I: Addressable Control Module for one Style VIZ (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0 (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. NC-100: Addressable Control Module for one Style VIZ (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. FRM-I: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SM13500. NC-I OOR: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NBG-I2LX: Addressable manual pull station with interface module mounted inside. NOT-BGI2LX: Addressable manual pull station with interface mod- ule mounted inside. ISO-X: Fault Isolator Module. NIOO-ISO: Fault Isolator Module. ISO-6: Six-fault isolator module. Mount one or two modules in a BB- XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SMB500: Used to mount all modules except FMM-10I/NMM-100P. NMM-I00-I0: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NZM-I00-6: Six-zone interface module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SWIFT Wireless Devices FWSG: Wireless Gateway FWD-200P: intelligent, wireless photo detector. FWH-200R0R135: LiteSpeed intelligent wireless rate of rise (135°) heat detector. FWD-200ACCLIMATE: Wireless Acclimate Detector FWH-200F1X135: intelligent wireless fixed-temperature (135°) heat detector. FW-MM: Intelligent wireless monitor module. FW-RM: Intelligent wireless relay module NBG-I2LW: Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the Fire Warden-50X, see the following data sheets (document numbers): NP-200 Series (DN-60979), NH-200 Series (DN-60980), FSP-851 Series (DN-6935), FSP-951 Series (DN-60977), FST-851 Series (DN-6936), FST-951 Series (DN-60975), FAPT-851 (DN-6937), NIOO-ISO (DN-6994), NP-100 series (DN-6995), NH-IOOINH-IOOR (DN-6997), DNR/lnnovairFlex (DN-60424, DN-60429), NP-A100 (DN-6998), NMM-100/NMM-I00P/NDM-100/NZM-100 (DN-6999), NC-100 (DN-7000), NC-1001? (DN-60383), NMM-100-10 (DN-6990), MM-1/FDM-IIFZM-1/FMM-101 (DN-6720), FCM-1/FRM-1 (DN-6724), NOT-BGI2LX (DN-7001), NBG-I2LX (DN-6726), and Fire Wa rden SLC Manual (52304). ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.9K): The 47k ohm assembly supervises the FMM-IINMM-I00-10, FDM-1/ NDM-100, FMM-I01/NMM-I00P, and FCM-1/NC-I00 module cir- cuits. The 3.9k ohm assembly supervises the XP6-MA/NZM-100-6 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. ON-60955:C • 7/16/2018 - Page 3 of 4 SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits................................................1 Addressable device capacity....................................................50 Programmable software zones.................................................50 Annunciators.............................................................................16 Electrical Specifications AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, auto-sensing- no switch required. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. NFPA Standards Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger The FireWarden-50X complies with the following NFPA 72 Fire Capacity: 7-18 AH (FireWarden-50X cabinet holds maximum of two Alarm Systems requirements: 18 AH batteries.) - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides connec- tions for two NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 250mA regulated. End-of-Line Resistor: 4.7k ohm, % watt (P/N 71252 UL listed) for Style V (Class B) NAC; system capable of 1.9 W - 22 kL ELR range. Refer to the NOTIFIER Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, non-power-limited, non-supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR- CE/B): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. sory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Net- work) - IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). - CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic Fire Warden-50X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. ° UL: S635 CSFM: 7165-0028:0505 ° FDNY: COA #6268 NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com Iso 9001 c-I at - • 1111=11 I BRINMINS I MMIIIUC Oliblil? SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. Al specifications are subject to change without notice. PJannNet®, NO11FIER0, FireWarden®, SWIFT®, and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft and Windows® are registered trademarks of the MiarnasS Corporation. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Country of Origin: USA NOTIFIER® by Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0028:0505 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywelI.com DESIGN: Models' FireWarden-50X (NFW-50X)and FireWarden-IOOX *(NFW IOOX) Fire Alarm Control Units. Automatic, manual, waterfowl, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. The FireWarden-50X (NFW-50X) is a compact version of the FireWarden-IOOX *(NFWIOOX) The FireWarden-50X (NFW-50X) has 50 addressable device capability and 2 Notification Appliance Circuits with a 3.0 amps total 24VDC output in Alarm. The FireWarden-IOOX *(NFW..100X) has 198 addressable device capability and 4 Notification Appliance Circuits with 3.oamps total 24VDC output in Alarm expandable to 6.0amps with Model PWRMOD24. The Model IPOTS-COM provides Phone and lP communication. Models FireWarden-50X (NFW-50X) and FireWarden-IOOX *(NFw..IooX) system components are as follows: lPOTS-COM POTS and IP Communicator 4XTMF Transmitter Module N-ANN-80 Remote Annunciator Module ANN-1 00 Remote Annunciator Module N-ANN-I/O LED Driver Module N-ANN-S/PG Serial/Parallel Interface Module N-ANN-RLY Form-C Relay Module N-ANN-LED Annunciator Module N-ANN-RLED Annunciator Module CELL-MOD GSM Communicator DP-ES-R Dress Panel Model FireWarden-IOOX *(NFW..100X) system components are as follows: PWRMOD24 NAC Power Expander Module Refer to the listee's data sheet for additional detailed product description and operational considerations. RATING: I20/240Vac 50/60Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. *Rev 09-03-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7165-0028:0505 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units, emergency alarm system control units and process management equipment for use with separately listed compatible initiating and indicating devices. Refer to Manufacturers Installation Instruction Manual for details. NOTE: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. XLF: 7165-0075:0500 *Rev 09-03-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division & FRM.1(A) (FCMN I (A) Series Control and Relay Modules NOTIFIER® by Honeywell DN-6724:B3 General FCM-1(A) Control Module: The FCM-1 (A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1 (A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1 (A) Relay Module: The FRM-1 (A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1(A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM-1(A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 —99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1 (A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1 (A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScan@ releasing applications. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01 -159). - F "IE M P -WR LaTo TICEMPWRM USP*tNtU*h1I l 'I _r• 'LL ' r FCM-1 (A) The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1(A) provides two Form-C dry contacts that switch together. Operation Each FCM-1(A) or FRM-1(A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) DN-6724:B3.2/1712011—Page 1 012 Maximum NAC Line Loss: 4 VDC. Contact Ratings for FRM-1 (A) External supply voltage (between Terminals Ti 0 and Til): Maximum (NAG): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (114.3 mm) high x 4" (101.6 mm) wide x 1.25° (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM.1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll; 255 pA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4° (101.6 mm) wide x 1.25' (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S3705 (A version only) FM Approved CSFM: 7300-0028:0219 MEA: 14-00-E FDNY: COA #6067, #6065 Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9A 125 VDC Resistive Non-Coded A .5 30 VDC Inductive Coded (UR5ms) 1A 30 VDC inductive Coded (LIR=2ms) A .3 125 VAC Inductive Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: °A" suffix indicates ULC Listed modeL lFCM-1(A): intelligent Addressable Control Module. FRM-1(A): intelligent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1 (A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document 156-1169. FRM-1(A) Installation document 156-3502. Notifier SLC Wiring Manual, document 51253. Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I So 9001 We try to keep our product information up-to-date and accurate. &rg We cannot cover all specific applications or anticipate all requirements. I&lN Mij& MRNUFACI1RINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifler.com Page 2 of 2- DN-6724:B3 • 2/17/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING. BUILDING MATERIALS LISTING PROGRAM IL LISTING SERVICE LISTING No. 7300-0028:0219 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484.6544 Fax (203) 484.7309 Email: megan.sisson@honeywell.com DESIGN: Models XP6.R relay module, XP6-C, supervising control module, XPIO-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor module FCM-i) FIRMA control modules, and *FDRM..1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16.33 VOC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2.640 (CSFM Listing No. 7165.0028:214), NFS-3030, NFS2.3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: if an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10.24-11 mt ,e This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division FCPS-24S6(C/E) 81 FCPS (4S8(CIE) - 6- & 8-Amp 24-Volt Remote Power Su General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger. The FCPS-24S6/- 24S8 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance (bell) circuit (NAC) expansion (to support ADA requirements and NAG syn- chronization) or auxiliary power to support 24 volt system accessories. The FCPS-24S6/-2458 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable, all resettable or two non- resettable and two resettable. The FCPS-2456/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C & FCPS-24S8C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E Features UL-Listed NAC synchronization using System Sensor, Wheelock, or Gentex "Commander2" appliances. Operates as a "sync-follower" or as a "sync-generator" (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAG (NAC expander mode) or jumped perma- nently "ON" (stand-alone mode). Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module) NACs. 6-amp (FCPS-2456) or 8-amp (FCPS-2458) full load out- put, with 3 amps maximum/circuit, in NAC expander mode (UL 864). 4-amp (FGPS-24S6) or 6-amp (FCPS-2458) continuous output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NACs. Selectable earth fault detection. AC trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9 - 32 VDC. Self-contained in compact, locking cabinet - 15"H x 14.5"W x2.75D(cm: 38.1H x 36.83W x 6.985D). dn-6927:a NOTIFIER® by Honeywell Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FCPS-2456C/-2458C: 120 VAC, 60 Hz, 3.2A maximum. FCPS-2456E/-2458E: 240 VAC, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm2) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDC. Trigger Current: 2.0 mA (16-32 V); Per Input: 1.0 mA (9 -16V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): - FCPS-2456: 4.0 A maximum. - FCPS-2458: 6.0 A maximum. Total short-term current for all outputs (NAC expander mode): - FCPS-2456: 6.0 A maximum. - FCPS-2458: 8.0 A maximum. Secondary Power (Battery) Charging Circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. dn-6927:a • 04/30/09 - Page 1 of 2 Maximum current charge: 1.5 A. Maximum battery capacity: 18 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A (FCPS-2456) or 8.0 A (FCPS-2458). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A (FCPS-2458). Both resettable and non-resettable power options are available. Resettable outputs are created by con- necting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. *NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet (3,810 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACR When installed at the end of a NAC wire run, the FCPS-24S6/-24S8 can track (i.e. follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-2456/-24S8 is configured (via DIP switch set- tings) as a sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24S6/-2458 are configured (via DIP switch settings) as a "sync generator," the FCPS's sync input termi- nals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator" mode, the sync type (System Sensor, Whee- lock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-2456 and FCPS-24S8 comply with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635, S674 ULC Listed: S635 (FCPS-24S6C & FCPS-24S8C) CSFM Approved: 7315-0028:225 MEA: 299-02-E FM Approved Ordering Information FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24S6C: Same as above, ULC-listed. FCPS-24S6R: Same as FCPS-24S6 with red enclosure. FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. (FCPS-24S8J8.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8C Same as above, ULC-listed. FCPS-24S8R: Same as FCPS-24S8 with red enclosure. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power. BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). PS-1270: Battery, 12-volt, 7.0 AH (two required, see PS Series data sheet DN-1 109) System Sensor® and NOTIFIER® are registered trademarks of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so 9001 We try to keep our product information up-to-date and accurate. 93a :b We cannot cover all specific applications or anticipate all requirements. ENCINIFUNC & MANUF&CI1RINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-6927:a • 04/30/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0028:0225 Page 1 of I CATEGORY: 7315-- POWER UNITS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models FCPS-24S6 andi:CPS24Sare power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: I2O VAC, 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:0206 I-24-O3KK TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division BAT Series Batteries Sealed Lead-Acid General BAT Series Batteries are Power Sonic brand batteries. BAT Series (or Power Sonic brand) batteries are recommended for secondary power or backup power for all NOTIFIER fire alarm control equipment. Features Provide secondary power for control panels. Sealed and maintenance-free. Overcharge protected. Easy handling with leakproof construction. Ruggedly constructed, high-impact case (ABS, polystyrene, or polypropylene, depending on models). Long service life. Compact design. Agency Listings and Approvals The listings and approvals below apply to BAT Series Batteries. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Recognized Components: MH20845 (Power-Sonic) DN-6933:C1 • E-205 NOTIFIER® by Honeywell 6933c0v.Jpg Ordering Information BAT-1250-BP: 10-unit bulk pack of BAT-1250 (12 V 5 AH) BAT-1270-BP: 5-unit bulk pack of BAT-1270 (12 V 7 AR) BAT-12120-BP: 4-unit bulk pack of BAT-12120 (12V 12 AH) BAT-12180-BP: 2-unit bulk pack of BAT-12180 (12 V 18 AH) BAT-12260-BP: 2-unit bulk pack of BAT-12260 (12 V 26 AH) BAT-12550: single battery (12 V 55 AH) BAT-121 000: single battery (12 V 100 AH) Part Number Reference & Specifications Part Number Power Sonic Part Number Battery Description DIMENSIONS ______ Nominal Voltage ______ Nominal Capacity @20hr. rate A.H. Width Depth Height Height over terminal Weight - in. - mm - in. - mm - in. - mm - in. - mm - lb. kg. BAT-1250 PS-1250 12 5 sealed 4.21 17 4.1 T AT-1270) PS-1270 12 7 sealed 595 151 256 65 13.7 94 3.86 98 4 28 BAT-12120 PS-12120 12 12 sealed 5.95 151 3.86 98 3.7 94 394 100 7.92 359 BAT-12180 PS-12180 12 18 sealed 7.13 181 2.99 76 6.57 167 6.57 167 12.6 58 BAT-1 2260 PS-12260 12 26 sealed 6.56 167 6.97 177 4.92 125 4.92 125 17 711 BAT-12550 PS-12250 12 55 1 sealed 19.04 230 654 138 8.2 208 898 228 36 1633 BAT-121000 PS-121000 12 100 1 sealed 112 305 6.6 168 8.2 208 8.98 228 68 30.84 DN-6933:C1 • 7/13/2011 - Page 1 012 6.5 -13 6.0 -12 5.5 11 > 5.0 10 4.5 9 4.0 8 I) Characteristic Discharge Curves 1 2 3 5 10 2030 60 2 3 5 10 20 30 minutes hours Discharge Time @ 20CC (68F) 120% Effect of Temperature on Capacity 100% . 80% (C ' 60% a (C 0. ow 40% 20% 0% 20n ion on ion 200 30n 40n 500 60n Temperature (Degrees C.) go 0-00 WEI—, 0 ME d imaums 100% 90% 0 02 80% 70% ix 60% 40% 00/n Charging is NOT necessary unless II 100% of capacity - '? is required. V Charging before (4 iF) use is necessary to help recover full capacity. "n. Charge may fail to restore I full capacity. 40c 30CC 20CC (1040F) (86011F) (68-F) DO NOT let batteries reach this state. at left: PS-121000 Shelf-Life and Storage 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) i!=IiiUI MORINO MIUMM1121111 M M1 Uii 1.2 2.4 14.0 V 12.0 V (C 11.0V (C - lo.oV 9.oV 8.OV at left: PS-121000 Discharge Characteristics _200A__~J_~_ IÔOA 6 12 24 36481 2 4 68'1'0 20 40 MINUTES x HOURS Discharge Time - I'llJ I ururi'w is a regusrerco tracierrilrK or rioneyweiu unternationau inc. Batteries display trademarks of the manufacturer. 02011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. dl U .1 We cannot cover all specific applications or anticipate all requirements. M111EMINS & MANIMCIURINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6933:C1 n 7/13/2011 TG=7FS CELLULAR ALARM COMMUNICATOR TE LG UAR D t COMMERCIAL FIRE PRODUCT FEATURES I- Meets UL 864 requirements for sole, primary or backup path communications. i- Supports virtually all alarm formats for universal panel compatibility. I- Connects to your central station's PSTN or IP receivers. i- Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2010 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system, replacing all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS, the monthly communications bill decreases. By being able to signal failures to the central station within five minutes of an outage, the TG-7FS can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS because of the new five minute supervision mode. The TG-7F5 can also be installed as a backup path, and upgraded to sole path at a later date. TG=7FS CELLULAR ALARM COMMUNICATOR TE LG UAR D Power Transmit power: 1.0W-2.0W (maximum allowable). Power Consumption: 60mA (Standby) 250mA (Transmission). Transformer: 12VAC, 800mA UL listed plug-in. Radio Transceiver Dual band cellular and PCS GSM 850MHz: Class 4 (2 watts). GSM 1900MHz Class 10 watt) Antenna: 9" dipole with 2dBi gain, 12 ft of cable and universal mounting bracket. FCC part 15, 22, 24 and 68 compliant. ((Is) - ) - ø —I I Ce,,t,aI SIdI,on r-,re Telguard technology allows full data reporting for unlimited point- to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-0: External antenna. Physical Details TG7FS 75 Hx115 Wx35 D Shipping Weight 81bs Operating Environment 0°C to +50°C; up to 95% humidity (non condensing) Standard Features Full data reporting. UL Listings Automatic self-test (5 mm. & daily). Commercial Fire Commercial Burglary Residential 864 • control units & 365 • Police Station 985 • Household fire Power supply with battery harness, accessories for fire connected burglar warning systems Locking, red metal enclosure, alarm systems alarm units and 1023 • Household burglar Two programmable supervisory systems alarm systems 1610 • Central station trip outputs. burglar alarm units Alarm format support for 51A2, Contact ID, pulse (3x1, 4x2), modem Ile, & 111a2, DMP. - Telephone line monitor built-in, © L A— -M ELECTRONIC ()SECURITY with Standard Line Security. ASSOCIATION- LISTED, NFPA® INTERNATIONAL Telguard, a Division of Telular Corporation • 2727 Paces Ferry Road SE • Suite 1-800 Atlanta, GA 30339 USA 800-229-2326, Option 5 • www.Telguard.com • Copyright @2011 Telular Corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES . V LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (678) 264-2012 Fax (678) 264-2062 V Email: Tim.Masters@ametek.com DESIGN: Models TG7LAA02, TG7LA00I, TG7LAA0I, TG7LA002, TG7LAF0I, TG7LAF02, *TG7UBLA and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model TG7LAF0I, TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may V also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 11-27-19 gt V This listing is based upon technical V data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 V Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division !I"95iT Series Intelligent Plug-In Photoelectric Smoke Detectors General The NOTIFIER FSP-951 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combus- tion sources in accordance with more stringent code standards. The FSP-951 Series detector sensitivity can be programmed in the con- trol panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the FSP-951T. The FSP-951R is a remote test capable detector for use with DNR Series duct detector housings. FSP-951 series detec- tors are available for both FlashScan® and CLIP applications as designated. Features New modem profile for improved aesthetics. Designed to meet UL268 7th Edition. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory. Dual LED design provides 360° viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan sys- tems only). Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Expanded color options. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. Specifications Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC Applications: 0.5% to 3.5% per foot obscuration. Size: 2.0" (5.3 cm) high; base determines diameter. - B300-6: 6.1' (15.6 cm) diameter. - B501: 4" (10.2 cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.40z (96.4g) Operating Temperature range: FSP-951, 0°C to 50°C (32°F to 122°F). FSP-951 T, 0°C to 38°C (32°F to 100°F). DN-60977:A NOTIFIER® by Honeywell FSP-951 in B300-6 Base FSP-951 R installed in a DNR/DNRW, -20°C to 70°C (-4°F to 158°F). ULJULC Listed Velocity Range: 0-4000 ft/mm. (1219.2 rn/mm.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (571C). DETECTOR SPACING AND APPLICATIONS NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 200pA @ 24VDC (one communica- tion every five seconds with LED enabled). LED Current (max.): 4.5mA @ 24 VDC ("ON"). Installation FSP-951 series plug-in detectors use a separate base to simplify installation, service, and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60981. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring '7-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limita- tions between isolator modules and isolator bases. DN-60977:A • 4/17/18 - Page 1 of 3 Agency Listings and Approvals These listings and approvals apply to the detectors specified in this document. In some cases, certain detectors or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listed: S911 FM Approved CSFM: 7272-0028:0503 Product Line Information NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. °A" suffix indicates ULC Listed model. "IV" suffix indicates FlashScan and CLIP device. (SP-9517. White, low-profile intelligent photoelectric sensor, FlashS- can only. - FSP-951A: Same as FSP-951 but with ULC listing. FSP-951-IV: Ivory, low-profile intelligent photoelectric sensor. FSP-951A-IV: Same as FSP-951-IV but with ULC listing. FSP-951T: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FlashScan only. FSP-951TA: Same as FSP-951T but with ULC listing. FSP-951T-IV: Ivory, same as FSP-951T but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-951TA-IV: Same as FSP-951T-IV but with ULC listing. FSP-951 R: White, low-profile intelligent photoelectric sensor, remote test capable. For use with DNRIDNRW. FlashScan only. FSP-951RA: Same as FSP-951R but with ULC listing. For use with DNRA. FSP-951 R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable. For use with DNR/DNRW. FSP-951 RA-IV: Same as FSP-951 R-IV but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981 B300-6: White, 6" base, standard flanged low-profile mounting base. B300-6-IV: lvory,6" base, standard flanged low-profile mounting base. B300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B224B1-WH: White, isolator detector base. B224B1-IV: Ivory Isolator detector base. B224B1A-WH: White, Isolator detector base, ULC listing. B224B1A-IV: Ivory Isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base. B501-WHITE: White, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for B21OLP(A) base. base. ULJULC listed. RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a B501-BL: Black, 4" standard European flangeless mounting base. U.S. single-gang electrical box. For use with B501 (A) and B300(A)- UL/ULC listed. 6. B501-IV: Ivory color, 4" standard European flangeless mounting M02-04-00: Test magnet. base. UL/ULC listed. M02-09-00: Test magnet with telescoping handle. B501-WHITE-BP: Bulk pack of B501 -WHITE contains 10. B224RB-WH: White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. Page 2 of 3— DN-60977:A .4/17/18 02018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. S O9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I __________________ All specifications are subject to change without notice. I I U ENCINEMING A MNVFflJURING QUALITY SYSTEMS For more information, contact Notifier. Phone: (800) 627-3473, FAX: (203) 484-7118. www.notifier.com Page 3 of 3— DN-60977:A • 4/17/18 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL LISTING SERVICE LISTING No. 7272-0028:0503 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneyweIl.com DESIGN: Models FSP-951 FSP-951R, FSP-951T, FSP-951T-ISO, NP-200, NP-200R, and NP-200T analog addressable, photoelectric smoke detectors for open area and duct installations. Models FSP-951T, FSP-951T-ISO and NP-200T have complementary heat detectors. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed bases: *Model B7IOLP (CSFM No. 7300-0028:0173); System Sensor Models *13224131 *B224RB (CSFM No. 7300-1653:0126); B200S, B200SR (CSFM No. 7300-1653:0213); B200S-LF, B200SR-LF (CSFM No. 7300-1653:0238); *13501 *B210LP B300-6, B300-6-IS (CSFM No. 7300-1653:0109). System Sensor duct detector housings Models DNR and DNRW (CSFM No. 3240-1653:0209) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. *All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. *Revision 12/16/19 DCC This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division ()NOTIFIER® by Honeywell Intelligent Bases Standard, Relay, Isolator, Sounder, and Low-Frequency Sounder Bases General Intelligent FlashScan® and CLIP detector mounting bases are avail- able to install NOTIFIER detectors in any application. Bases are available for the new, modern looking aesthetically pleasing 900 series addressable detectors, as well as previous series detectors. Both flanged and flangeless bases are available. To meet code and specific application requirements Relay, Isolator and Sounder Bases versions are available. Relay bases provide one form-C contact for auxiliary functions such as door closure and elevator recall. Isolator bases allow loops to continue to operate under fault conditions and automatically restore when the fault is removed. Sounder bases are available in temporal and non-tempo- ral pattern versions depending on whether the signal is to be used for evacuation purposes. Low frequency sounder bases are UL listed for low frequency operation and comply with NFPA 72 require- ments for sleeping spaces. Specifications NOTE: Specifications applies to all model variants 'A", "-BL", '-LF", °1V". See Product Line Information for detailed model description. Diameter B501: 4° (10.16cm) diameter. B300-6: 6.1' (15.49 cm) diameter. B224Rl, B224RB, B21OLP: 6.2" (15.748 cm) diameter. B2005, B200SR, B200SCOA: 6.875" (17.46 cm) diameter. Wire gauge: • 13224131, B224RB: 14 to 24 AWG. B300-6, B21OLP, B501, B200S, B200SR, B200SCOA: 12 to 24 AWG Temperature range: 13224131, B224RB, B200S, B200SR, B200SCOA: 32°F to 120°F (0°C to 49°C). B300-6, B21OLP, B501: -4°F to 150°F (-20°C to 66°C). Humidity range: 10% to 93% RH, non-condensing. System temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 1201F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tem- perature ranges and humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). Electrical Ratings FOR 8200 SERIES BASES: External supply voltage: 16 to 33 VDC (VFWR) Standby current: 500 pA maximum. Alarm current: B200S(A)(-IV) - 35 mA maximum at high-volume setting. - 15 mA maximum at low-volume setting. B200S-LF(-IV), High-volume setting: r..i c angeless Mounting Base Flanged Mounting Base B501 (A) B21OLP(A) :-i Sounder Base Relay Base B200S(A), B200SR(A), B224RB(A) B200SCOA Low-Frequency Sounder Standard Flanged Base B200S-LF, Low-Profile Base B200SR-LF (B3OO-6J —70 mA maximum @ 33.0 VDC- - 90 mA maximum @ 24.0 VDC. - 140 mA maximum @16.0 VDC. B2005-LF(-IV), Low-volume setting: —15 mA maximum @ 33.0 VDC. —20 mA maximum @ 24.0 VDC. —25 mA maximum @ 16.0 VDC. B200SR(A)(-IV) - 35 mA maximum. B200SR-LF(-IV) —65 mA maximum @ 33.0 VDC. —90 mA maximum @ 24.0 VDC. - 125 mA maximum @16.0 VDC. B200SCOA(-IV) - 40mA Max. (DC) - 70mA Max. (FWR) SLC operating voltage: 15 to 32 VDC. SLC standby current: See applicable sensor specification. Sound output: B200S(A)(-LF)(-IV), high-volume*: Greater than 85 dBA mini- mum. B200S(A)(-LF)(-IV), lowvolume*: Greater than 75 dBA minimum. B200SR(A)(LF)(lV)*: Greater than 85 dBA minimum. B200SCOA(-IV), highvolume**: Greater than 87 dBA minimum. B200SCOA(-IV),' lowvolume**: Greater than 85 dBA minimum DN-60054:A • 04/18/18 - Page 1 of 4 Measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone) Measured in a ULC anechoic room at 10 feet, 24 Volts continuous tone) FOR B224B1, B224RB (A) (-IV): Operating voltage: 15 to 32 VDC (powered by SLC). Standby ratings: <500 pA maximum @ 24 VDC. Set time (B224RB(A)(-IV) only): short delay 55 to 90 msec; long delay 6 to 9 seconds. Reset time (B224RB(A)(-IV) only): 20 msec maximum. Relay characteristics (B224RB(A)(-IV) only): two-coil latching relay; one Form-C contact; ratings (ULJCSA): 0.9 A 0 125 VAC, 0.9 A 0 110 VDC, and 3.0A 0 30 VDC. Product Line Information INTELLIGENT BASES NOTE: W suffix indicates ULC Listed mode!. NOTE: "-IV" suffix indicates Ivory color mode!. NOTE: "-BL" suffix indicates Black color model. B21OLP: Flanged mounted base. B21OLPA: Same as B21OLP ULC listed. B21OLPBP: Bulk pack of B21OLP contains 10. (BoO: White, 6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109) B300A-6: Same as 8300-6, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B300-6-IV: lvory,6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109) B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B501-WHITE: White, 4" standard European flangeless mounting base. ULJULC listed. (CSFM: 7300-1653:0109) B501-WHITE-BP: Bulk pack of B501 -WHITE contains 10. B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109) B501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109) B224RB-WH: White, relay base. (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base. (CSFM: 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224B1-WH: White, isolator detector base. (CSFM: 7300- 1653.0216) B224B1-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216) B224B1A-WH: White, Isolator detector base, ULC listing. B224B1A-IV: Ivory Isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. Page 2 of 4— DN-60054:A • 04/18/18 B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz .r-/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as B200SR-WH with, ULC listing. 13200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base. TR300-IV: Ivory, replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B300(A)- 6. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR213. Comes in three 5-foot (1.524m) sec- tions. T55-1 27-010: Detector removal tool without pole. CK300: White, detector color kit. Pack of 10. CK300-IR: White, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. CK300-IV: Ivory, detector color kit. Pack of 10. CK300-lR-IV: Ivory, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. CK300-BL: Black, detector color kit. Pack of 10. CK300-IR-BL: Black, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. Agency Listings and Approvals The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL Listed: S911, S1115 ULC Listed: S911, S1115. FM Approved. MEA: 22-95-E, 205-94-E Vol. 2; 257-06-E CSFM: 7270-0028-0502, 7272-0028:0503, 7300-1653:0126, 7135-1653:0213, 7300-1653:0109 Junction Box Selection Guide Single i 4.0" Sq. Base Models Gang 3.5" Oct. 4.0" Oct. 4.0" Sq. with 3.0" 50 mm 60 mm 70 mm 75 mm mud ring B200S,B200SR, Yes Yes Yes Yes Yes No No No No B501 No Yes No No Yes Yes Yes Yes No B2IOLP Yes Yes Yes Yes Yes No No No No B224RB No Yes Yes Yes No No Yes Yes Yes B224Bi No Yes Yes Yes No No No Yes Yes NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. NOTE: Applies to all model variants NA", "-BL", "-LF", "-IV". See Product Line Information for detailed model description. DN-60054:A • 04/18/18 - Page 3 of 4 Iso 9001 .I dl Mll GlSltlllftl & MANItiflIfl5 ODAtICY SYSTEMS NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com This document is not Intended to be used for Installation purposes. We try to keep our product lnturrnallon up-to-dale and accurate. We cannot cover all specific applications or anticipate all requirements. M specifications are subject to change without notice. FlashScan®, NOTIFIER® and System Sensors are regis- tered trademarks of Honeywell International Inc. 02018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Country of Origin: USA jNOTIFIER® I by Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0109 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneyweIl.com DESIGN: Models B401, B401 B, B401 R, B401 BR, B401 BR-750, B401 R-750, B402B, B404B, B404BT, B406B, B501, B501 B, 14506587-002, B50IBH, B501 BHT, B40IBH, B110LP, BIIORLP, BIIORLP75O, BII2LP, BII4LP, BII4LPBT, 13II6LP, B2IOLP, B501-BL, B501-IV, *1350I.wHlTE(366 B300-6-IV, B300-6-IS detector bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, *model number, *electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. *Refer to Manufacturers Installation Instruction Manual for details. NOTE: Formerly 7300-1209:128 *Rev 04-03-18 gt Ti This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division ©)NOTIFIER® by Honeywell (i~P-~2160),Series Photoelectric Smoke Detectors for FireWarden Series The NOTIFIER® NP-200 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the NP-1 00 Series. A new modern, sleek, contem- porary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. Exclusively for use with NOTIFIER's FireWarden Series address- able fire alarm control panels, the NP-200 Series point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indi- cation. The NP-200 Series also offers 135°F (57°C) fixed temperature ther- mal sensing on the NP-200T and a remote test capable detector on the NP-200R for use with DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP: Two-wire SLC loop connection Unit uses base for wiring Compatible with FlashScan® and CLIP protocol systems Stable communication technique with noise immunity ADDRESSING: Addressable by device Rotary, decimal addressing (Refer to the FireWarden panel manuals for device capacity.) ARCHITECTURE: Sleek, low-profile, stylish design Unique single-source design to respond quickly and dependably to a broad range of fires Integral communications and built-in device-type identification Built-in tamper resistant feature Remote test feature from the panel Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only) Built-in functional test switch activated by external magnet Removable cover and insect-resistant screen for simple field cleaning Expanded color options OPERATION: Designed to meet UL 268 7th Edition Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level LED "blinks" when the unit is polled (communicating with the fire panel) and latches in alarm. Low standby current MECHANICALS: Sealed against back pressure SEMS screws for wiring of the separate base Designed for direct-surface or electrical-box mounting Plugs into separate base for ease of installation and maintenance Separate base allows interchange of photoelectric, ionization and thermal sensors OPTIONS: Optional relay, isolator, and sounder bases Installation NP-200 Series plug-in intelligent smoke detectors use a detachable base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. Mount detector base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring only. When using relay or sounder bases, consult the N100-ISO installation sheet 156-3625 for device limitations between isolator modules and iso- lator bases. Construction These detectors are constructed of fire-resistant plastic. The NP-200 Series plug-in intelligent smoke detectors are designed to commer- cial standards and offer an attractive appearance. Operation Each NP-200 Series detector uses one of the panel's addresses (total limit is panel dependent) on the FireWarden Signaling Line Cir- cuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The NP-200 Series offers fea- tures and performance that represent the latest in smoke detector technology. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an FireWarden Series addressable fire alarm control panel. The results of the sensitivity test can be printed for record keeping. DN-60979:B • 7/1/2019 - Page 1 of 3 Product Line Information NOTE: "-IV" suffix indicates CLIP and FlashScan device. OÔ'White, low-profile intelligent photoelectric sensor, FlashS- can onl7 NP-200-IV: Ivory, low-profile intelligent photoelectric sensor NP-200T: White, same as but includes a built-in 135°F (57°C) fixed- temperature thermal device, FlashScan only NP-200T-IV: Ivory, same as T but includes a built-in 135°F (57°C) fixed-temperature thermal device NP-200R: White, low-profile intelligent photoelectric sensor, remote test capable, for use with DNRIDNRW, FlashScan only NP-200R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300-6-IV: lvory,6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. ULIULC listed (CSFM: 7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-WHITE-BP: Bulk pack of B501-WHITE contains 10 B224RB-WH: White, relay base (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base (CSFM: 7300-1653:0216) B224B1-WH: White, isolator detector base (CSFM: 7300-1653:0216) B224B1-IV: Ivory isolator detector base (CSFM: 7300-1653:0216) B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base TR300-IV: Ivory, replacement flange for B21OLP(A) base RAIOOZ(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B300-6(A). M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: Color Kit (includes cover and trim ring), white, 10-pack CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack Page 2 of 3— DN-60979:B • 7/1/2019 SPECIFICATIONS Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0° (5.3 cm) high; base determines diameter - B300-6: 6.1" (15.6 cm) diameter - B501: 4° (10.2 cm) diameter For a complete list of detector bases see DN-60981 Shipping weight: 3.4 oz. (95 9) Operating temperature range: NP-200: 32°F to 122°F (0°C to 50°C) NP-200T Series: 32°F to 100°F(0°C to 38°C) NP-200R Series installed in a DNR/DNRW, -4°F to 158°F (-20°C to 70°C) ULIULC Listed Velocity Range: 0-4000 ft/mm. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10% - 93% non-condensing Thermal ratings: fixed-temperature set point 135°F (57°C), rate-of- rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15-32 volts DC peak Standby current (max. avg.): 200pA @ 24 VDC (one communica- tion every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC ("ON") DETECTOR SPACING AND APPLICATIONS NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document A05-1003, is avail- able at www.systemsensor.com. Listings and Approvals Listings and approvals below apply to the NP-200 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ° UL/ULC Listing: S1115 FM Approved CSFM: 7272-0028:0503 Iso 9001 C-aat - • - • .1 mrrtse i OOAIITY SYSTEMS This document is not intended to be used for installation purposes. We by to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. Al specifications are subject to change without notice. NOTIFIER FireWarden®, RashScan®, NOTIFIER®, and System Sensor® are regis- 12 Clintonville Road tereri trademarks otHoneywell International, Inc. Northford, CT 06472 02019by Honeywell International Inc. Al rights reserved. Unauthorized 203.484.7161 use of this document is strictly prohibited. www.notifier.com Country of Origin: Mexico NOTIFIER® I by Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:0503 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeyweIl.com DESIGN: Models FSP-951, FSP-951 R, FSP-951 T, FSP-951 T-ISO' R'NP-200R, and NP-200T analog addressable, photoelectric smoke detectors for open area and duct installations. Models FSP-951T, FSP-951T-ISO and NP-200T have complementary heat detectors. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to Iistee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with Iistee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed bases: *Model B7IOLP (CSFM No. 7300-0028:0173); System Sensor Models *B224Bl, *B224RB (CSFM No. 7300-1653:0126); B200S, B200SR (CSFM No. 7300-1653:0213); B200S-LF, B200SR-LF (CSFM No. 7300-1653:0238); *B501 *B210LP B300-6, B300-6-IS (CSFM No. 7300-1653:0109). System Sensor duct detector housings Models DNR and DNRW (CSFM No. 3240-1653:0209) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. *All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. *Revision 12/16/19 DCC TO This listing is based upon technical data submitted by the applicant. CSFM Fire the test results and/or other data but does not make an independent verification Engineering staff has reviewed of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CP;OT-BG1 2LXD Addressable Manual Pull Station DN-7001:D • Ai-380 Ar Intelligent/Addressable Devices The Notifier NOT-BG12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels, and the NSP-25 panel. Because the NOT-BG12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/o) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4° (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 iJA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Installation The NOT-BG12LX will mount semi-flush into a single-gang, double-gang, or standard 4(10.16cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NOT-BG12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The NOT-BGI2LX Addressable Manual Pull Station The BG1 2TR is usually needed for semi-flush mounting with 4° (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 —99 on NFW2-100/NFW2-100C, 1 —50 for NFW-50/NFW- 50C). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-i 0 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4 (10.16 cm) square electrical box, and shall be installed DN-7001:D.4/13/2012—Page 1 012 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information N0T-BG12LX Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E Vol. IV. CSFM: 7150-0028:0199. FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER® is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 1111INERINS 9 MANVACT1111ING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-7001 :D • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL LISTING SERVICE LISTING No. 7150-0028:0199 Page 1 of I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywelI.com DESIGN: Models NBG-12, NBG-12S, NBG-I2LR, NBG-I2LRA, NBG-I2LAO, NBG-I2LAOB, NBG-12-LO, NBG-I2LOB, NBG-12W, NBG-I2LW, NBG-I2NC, NBG-I2WP, NBG-I2LWP, NBG-12L, NBG-I2LX, NBG-I2LA, NBG-I2PS, NBG-I2LSP, NBG-I2LPS, NBG-I2LPSP, NBG-12S7121_ NBG-I2LXSP, NBG-I2LXBL and NBG-I2LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-I2LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-I2WP, NBG-I2LW, NBG-12W, NBG-I2LWP, NBG-I2LAO, NBG-12L0, NBG-I2LAOB and NBG-I2LOB are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. *Corrected 10-08-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct EIVi operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division c- SYSTEM $ SENSOR® Outdoor Selectable- Output Horns, Strobes, and Horn Strobes SpectrAlert Advance outdoor selectable-output horns, strobes, and horn strobes are rich with features that cut installation times and maximize profits. Features Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall and ceiling units: 15,15/75, 30,75,95,110,115,135,150,177, and 185 Plug-in design with minimal intrusion into the back box Tamper-resistant construction Universal mounting plate for wall- and ceiling-mount units Mounting plate shorting spring tests wiring continuity before devices are installed Weatherproof per NEMA Or 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Rated from —40°F to 151°F Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Aaencv Listinas SIGNAUNG <E3> MEA 7300-1 653:187 (outdoor strobes) 54011(chlrrres, horn strobes, horns) APPROVED approved 7125-1653:188 (horn strobes, chime strobes) 53593 (outdoor and alert strobes) 3023572 MEA452-05'b 7135-1653:189 (horns, chimes) The SpectrAlert Advance series offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, SpectrAlert Advance outdoor horns, strobes, and horn strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from —40°F to 151°F. Like the entire SpectrAlert Advance product line, these devices include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. All horns, strobes, and horn strobes use a universal mounting plate with an onboard shorting spring that tests wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12- or 24- volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit- Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95,110,115,135,150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per ULThe strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern.These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151°F (-40°C to 66°C) Strobe Flash Rate -- 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/F WR1 Operating Voltage Rang& 8 to 17.5 V (12 V nominal) or 16 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18AWG Ceiling-Mount Dimensions (including lens) 6.8diameter x 2.5 high (173 mm diameter x 64mm high) Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 2.5"D (142 mm Lx 119 mm W x 64mm D) Horn Dimensions 5.6Lx4.7"Wx 130(142mm Lx 119 mmWx33 mm 0) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7"L x 5.1"W x 2.0'D (145 mm Lx 130 mm W x 51 mm D) Ceiling-Mount Weatherproof Back Box Dimensions (SA-WBBC) 7.1 diameter x 2.0 high (180 mm diameter x 51 mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0456-01 UL Current Draw Data iii U 1I(rrr(Ti'ip ,J1vsnm1:fN iii ;riiuiiti 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (rnA RMS), 2-Wire Horn 16-33 Volts Strobe, High Candela Range (1135-185 cd) 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) - - - 1A_II+ -II.3 IO-5 Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 Strobe Output (cd) Listed Candela Candela rating at -40°F 15 Do not use below 32°F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 S Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 Coded Low 75 75 81 81 88 85 96 92 Settings 7, 8, and 9 are not available on 2-wire horn strobe. A05-0456-OO1 SpectrAlert Advance Dimensions IJU!!1 Wall-mount horn strobes Wall weatherproof back box I Ceiling-mount horn strobes Ceiling weatherproof back box SpectrAlert Advance Ordering Information Wall Horn Strobes (Ai 2-Wire Horn Strobe, Standard cd, Red, Outdoor P2RHK.t2-Wire Horn Strobe, High cd, Red, Outdoor P2WK' 2-Wire Horn Strobe, Standard cd, White, Outdoor P2WHK 2-Wire Horn Strobe, High cd, White, Outdoor P4RK 4-Wire Horn Strobe, Standard cd, Red, Outdoor P4W1< 4-Wire Horn Strobe, Standard cd, White, Outdoor P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120V Wall Strobes SRK*f Strobe, Standard cd, Red, Outdoor SRHK*t Strobe, High cd, Red, Outdoor SWK Strobe, Standard cd, White, Outdoor SWHlK*t Strobe, High cd, White, Outdoor Notes: Ceiling Horn Strobes PC2RK 2-Wire Horn Strobe, Standard cd, Red, Outdoor PC2RHK 2-Wire Horn Strobe, High cd, Red, Outdoor PC2WK 2-Wire, Horn Strobe, Standard cd, White, Outdoor PC2WHK 2-Wire, Horn Strobe High cd, White, Outdoor PC4WK 4-Wire, Horn Strobe, Standard cd, White, Outdoor PC4WHK 4-Wire, Horn Strobe, High cd, White, Outdoor Ceiling Strobes SCRK Strobe, Standard cd, Red, Outdoor SCRHK Strobe, High cd, Red, Outdoor SCWK Strobe, Standard cd, White, Outdoor SCWHK Strobe, High cd, White, Outdoor Horns HRK Horn, Red, Outdoor Add -P"to model number for plain housing (no FIRE marking on cover), e.g., P2RK-R t Add -Rto model number for weatherproof replacement device (no back box included), especially for use with weatherproof outdoor flush mounting plate, W1P and WTPW. Standard cd refers to strobes that include 15, 15/75, 30, 75,95, 110, and 115 candela settings. High cdrefers to strobes that include 135, 150, 177, and 185 candela settings. "S TEM C25O9 System Sensor. 3825 Ohio Avenue. St. Charles, IL 60174 Product specfficatlonsrubJeotoohongewithout noace.vsIS 59s1e1rn00101r0r0 for SE7'J5OR Phone: 800-SENSOR2. Fax: 630-377-6495 current product Iriformadon, Inducing the latest version ofthis data sheeL 905-0456-001 .06/09-92190 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneyweIl.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, 'or may be followed by suffix "P" for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDCIFWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *hom/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division F- -- t ACE-Il FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SIB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 ¼ deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information ISO 9091 J 'Space AgeEleconiIlnc. REGISTERED www.lsae.com NFPA OMPANY 800.486.1723 Toll Free MV Made In U.S.A. \.-' 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 ED0549 LT10559 Rev.D 1/2 No Excuses, Just Solutions! APSPACE AGE OW ELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-B Connector Property In1m,tion Minhrnrn R.qol,.d D0crnnent0600 (SIG-FUN) (0.06PA.712013&07.21) 0,.Iq44.: Cortifimiti =c'als o,dor 4*06 06..'IGI*n,0.ha 106 16.5 Aoth0llly Having Jurisdiction: 06106 dl. ___________ 10 C4.d I0l.dd06*, 0I .l06sdd. 061 74.0 1d 74.2 106 11 C.fll0*.02d12 .S0.a106,. .200*0* Eq1.Ipnlent Inf0n,l000n 120*02.020606*0*. 064U.1702 .I*0I....l.l 1110644 Roll Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations Ordering Information: Part # Description (u0068) Fire Alarm Storage Cabinet RED Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0549 LT10559 Rev.D 2/2