HomeMy WebLinkAbout1380 LAUREL TREE LN; ; FPR2023-0048F11iIl11I']it4I (L'City of Carlsbad Print Date: 07/15/2024 Job Address: 1380 LAUREL TREE IN, CARLSBAD, CA 92011 Permit Type: FIRE-Construction Residential Work Class Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Permit No: FPR2023-0048 Status: I Closed - Finaled Multifamily Fire Alarm Applied: 05/23/2023 Issued: 06/06/2023 Finaled Close Out: 07/12/2024 Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Cheung, Nathaniel Plan Check #: Salcedo, Felix Robinson, Jarrod Project Title: Description: AVIARA APARTMENTS EAST - NEW FIRE ALARM SYSTEM FOR NEW CONSTRUCTION OF A 4-STORY BLDG (316 DEVICES) Applicant: FPContractor: EMCOM ELECTRONIC SYSTEMS EMCOM ELECTRONIC SYSTEMS INC DAVID GENIS 256 WITH ERSPOON WAY, U STE H 256 WITHERSPOON WAY, U H EL CAJON, CA 92020-2755 EL CAJON, CA 92020-2766 (619) 667-1200 (619) 654-6687 FEE AMOUNT FIRE New Alarm System $1,499.00 Total Fees: $1,499.00 Total Payments To Date: $1,499.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Fire Alarm System Equipment Submittal Aviara East 1380 Laurel Tree Ln, Carlsbad, CA 92009 CBR2022-1327 INTELLIGENT FIRE ALARM CONTROL PANEL FX-2000 SERIES Description Mircom's FX-2)30 Series Microprocessor Based IntE ligent Fire Alarm Control Panel is designed to provide maximum flexibility of analog system reqLirements while also providing easy installation and operation a: a cost-effective price The FX-2000 base panel consists of one intelligent anabg loop coifrollercaDable of supperting 99 Analog Ser.sors and E 9Addressable Modules which can be wired in Class A Style 6017) or ClasE B (Style 4). The system can be expanded by adding Edditional Analog Loop Controller Modules. In addition the base panel supports 16 cowentional hardwire adder modules suc- as the DM-1 308A Initiating CircL it Module ISGM- 1004A Indicating Circuit Module and the RM-1008A Relay Circuit Motile. Additional conventional hardwire adder moduleE can be added with the ALC-H 16 Adder Hariwire Loop Controller Module, which allows the syslem to supporl an additonal 16 coiventional adder modules. The base panel also consiEts of 4 CLass AIB (Style Z/Y) Ind cating Circuits rated at 1.7 Amps each and either a 6 or 12 Amp Power Suply. EqLlpped with a large x 20 Back-lit Alphanumeric LCD display,. ti-e- FX-2000 utilizes a simple Menu system complete with a d rectional keypad, common con:o1 switches and LEDs Alarm Queue switctes and LEDs and two coifiguraDle input swi:ches. Features Listed to UL 864, 9th edition Large system capacity Modular design Each Analog Loop is capable of supporting 99 Analog Sensors and 99 Addressable Modules which can be wired in Class A (Style 6 or 7) or Class B (Style 4) Base system supports 16 conventional hardwired modules with the provision to add more using the ALC-H 16 Hardwire Loop Controller Module 6 or 12 Amp power supply Four Class NB (Style ZIY) Indicating Circuits rated at 1.7 Amps each Configurable for Two Stage operation Three level password protection with field programmable definition which enables the installer to determine what functions are accessible for each password level Panel Security to protect site configurations Manual Control Enable which allows password protection for all front panel function switches Correlatable Switch Inputs which allows for multi- functional outputs Four Alarm Queues with selector switches and LEDs for Alarm, Supervisory, Monitor and Trouble Auxiliary relay contacts for Common Alarm, Common Supervisory and Common Trouble RS-232 output for remote system printer or CRT Two Event History Logs comprised of a 1000 Alarm History Log for alarm related events and a 2000 Event Log for all events Front Panel Auto-Configure and/or Computer laptop Programmable Large 4 by 20 character Back-lit LCD Display with user friendly menu Common Control switches and/or indicating LEDs for System Reset, Signal Silence, Fire Drill, Acknowledge, General Alarm, Lamp Test, A.C. On, Pre-Alarm and Ground Fault Built-in One Man Walk Test operation Configurable for Coded Operation Supports an RS-485 interface to the QX-5000 Voice Evacuation System Panel selection for Canadian (ULC) or U.S.A. (UL) requirements for smoke sensors (sensitivity) via computer laptop Capability to adjust Intelligent Smoke Detector sensitivity level ®@ 1!Cit MEACIass S7010 S7010 7165-1477:111 approved Cass I(dd) E15097 Class 11 (Add) El 5098 7170-1477:119 313-97-E Highrise CATALOG NUMBER cn4 f NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves ti-c right to nake changes at ary .ime without notice in prices, :olours, materials, components, equipment, specifications and models and also to discontinue models. The FX-2000 is field programmable via the front panel auto configuration or a laptop computer. In addition, it allows for a three level password protection that can be field defined via a laptop computer. This unique feature allows the installer to determine what functions are accessible for each password level. The system is also equipped with two Event History Logs; one for Alarm and the other for full panel sequence events. The Alarm History Log (1000 events) contains all alarm related functions while the Event Log (2000 events) provides a full sequence log of all operations, as well as alarms and troubles. Both Event History Logs can be used during the One Man Walk Test operation. This allows the event logs to be downloaded to a laptop or printer for a permanent record. The FX-2000 is a very flexible system which supports both internal and external annunciation modules. The internal annunciation modules consist of the RAX-1048TZDS Programmable Zone LED Annunciator, the I PS-2424DS Programmable Input Switches Module, the FDX-008 Fan Damper Module and the AGD-048 Adder Graphic Driver Module. I nput Correlations All input circuits (addressable or hardwired) can be configured for non-verified alarm, verified alarm, waterfiow, latching/non-latching supervisory, monitor, trouble only or remote switch inputs. All of the input configuration types listed above, with the exception of remote switch can be programmed to operate relays, signal and strobe circuits for hardwired or addressable devices. Please refer to the chart below for correlations. The input circuits configured as non- latching will cause the output circuits configured to them to follow the state of the input device. This feature allows for the connection of multiple panels together for signal operation. All of these modules mount within the panel and are driven from the main LCD display. The external annunciator modules include the RAM-1032TZDS and RAX-1048TZDS LED Remote Annunciators, the MGD-32 Master Graphic Driver Module, and the RAX-LCD Remote LCD Shared Display. The RAX-LCD Remote LCD Shared Display provides the same features as the main display on the FX-2000. In addition the RAX-LCD also acts as a driver module that allows for the RAX-1048TZDS, IPS-2424D5, FDX-008 and AGD-048 to be connected to it. The RAX-LCD is required as a driver module any time any of the above mentioned external annunciator modules are programmed differently from those on the main panel or are mounted remote from the main panel. In addition to these adder modules, the FX-2000 also supports the UDACT-300A Digital Communicator Module and the PR-300 Polarity Reversal/City Tie Module. The FX-2000 also supports an RS-485 interface to the QX-5000 Emergency Zoned Audio System. The Remote Switch input, which must be momentary, allows any input type device (addressable or hardwired) to be configured as a common control functions such as fire drill, system reset, signal silence etc. The remote switches operate in a momentary mode like the control switches on the FX- 2000 main panel. For functions such as fire drill, the remote switch functions in a toggle mode, with one press for "on" and one press for "off'. The remote switch is supervised for 'stuck in on" positions, where the switch input is activated (stuck) for more than 30 seconds. If this occurs, a trouble is generated and clears when the input goes away. Intelligent or Conventional Input Types Output Control Switches Strobe Relay Signal Non-Verified Alarm Yes Yes Yes No Verified Yes Yes Yes No Waterfiow Yes Yes Yes No Non-Latching Supervisory Yes Yes Yes No Latching Supervisory Yes Yes Yes No Monitor Yes Yes Yes No Trouble Only Yes Yes Yes No Remote Switch Input No No No Yes 1I i rco m • NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 2 of 10 FX-2000 Standard Series FX.2003.6DSIFX-2003-12DS Compact Main Control Units The FX-2003-6DS and FX-2003-12DS Compact Mair Control Units come complete with one Intelligent 3gnaling Line Circuit Four Style ZIY (Class NB) Notification Appliance Crcuits rated at 1.7 Amps each and a 4 line by 20 character back-lit LCD display. The FX-2003-6DS is equipped with a 6 Amp Power Supply which charges 0-24 AH batteries while the FX-2003-12DS includes a 12 Amp Power Sup Q4 which charges 17-! AH batteries. The FX-2003-6DS/FX-2003-12D5 povides space for 3 adder modules and 2 internal annunciator adder nodules. The X-2CO3-6DS/FX-2003-12DS mount in a UB-1024D5 backbo:x. FX-2003-6DS-1 6LED Compact Main Control Unit The FX-2003-6DS-16LED Compact Main Cortrol Unit come complete with one Intelligent Signaling Line Circuit, Four Style Z/Y (C ass A/13) Notification Appliance Circuits rated at 1.7 Amps each nd a 4 line by 20 character back-lit LCD display with 16 LEDS -or annunciation (DSPL-420-16TZDS). This display is functionally eqL ivalent to the c assic FX-2000 main display, but more compact adding in the 15 LEDs annunciation in addition to all the standard functions.—I he FX-2003-6DS-16LED is equipped with a 6 Amp Power Supply whcb charges 0-2k AH batteries. The FX-2003-6DS-16LED provides space for 3 aider mcdules and 2 internal annunciator adder modules The FX-200-6DS-16LED mounts in a separate ordered UB-1024DS Eackbox FX-2017-I2ADS Mid-Size Main Control Unit The FX-2017-12ADS Mid-Size. Main Control Unit comes complete with one intelligent Signaling Line Circuit(SLC). Four StyleZlY (ClassNB) NAC Ciruis (1.7 Amps each), a 4 line by 20 character back-lit LCD display and a 12 Amp Power Supply which charges 17-55 AH batteries. The FX-2017-12ADS has space for up to 17 adder modules and 3 internal annunciator adder modules. The FX-2017-12ADS mounts in the BBX-1072ADS enclosure. FX-2009-I2DS Large Size Main Control Unit The FX-2009-12D5 Large Size Main Control Unit comes complete with one Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 Class A/B (Style Z!Y) Indicating Circuits (1 7 Amps each), a 4 line by 20 character back-lit LCD display and a 12 Amp Power Supply which charges 17-55 AH batteries. The FX-2009-12DS supports 16 conventional adder modules and provides space for up :o9 adder modules and 3 internal annunciator adcer modules. The FX-2009-12DS mounts in the BB-5000 Series enclosures. ECX-0012 Expander Chassis The ECX-0012 Expander Chassis for the FX-2009-123S/FX-2009S-12 supports up to 12 adder modules and has space for 2 internal annunciator modules. The ECX-0012 mounts in the BB-5000 series enclosures. FX-2000 Standard Series System Maximums 495 Input Circuits 150 Output Circuits 5 Intelligent Addressable Loops 4 Remote LCD Annurciators 4 Main LED Annurciators 100 Manual Control Switches 40 CAT. 5910 rcom .. NOT TO BE USED FOR INSTALLATION PURPOSES. page 3 of 10 Adder Loop Controller Modules Adder Hardwire Modules ALC-198S Single Analog Loop Controller Module The ALC-1 98S Single Analog Loop Controller Module provides an additional analog loop to the FX-2000 consisting of 99 Analog Sensors and 99 Addressable Modules. The ALC-1 98S occupies one module slot in the FX-2000 main or expander chassis. ALC-396S Dual Analog Loop Controller Module The ALC-3965 Dual Analog Loop Controller Module provides two additional analog loops to the FX-2000 consisting of 99 Analog Sensors and 99 Addressable Modules per loop. The ALC-396S occupies one module slot in the FX-2000 main or expander chassis. ALC-1-1116 Hardwire Loop Controller Module TheALC-H16 Hardwire Loop Controller Module allows the FX-2000to support an additional sixteen (16) conventional hardwire adder modules. The hardwire modules consist of the DM-1008 Eight Initiating Circuit Module, SGM- 1004 Four Indicating Circuit Module and the RM-1008 Eight Relay Circuit Module. The ALC-H16 occupies one module slot in the FX-2000 main or expander chassis. Adder Auxiliary Modules DM-1008A Eight Initiating Circuit Module The DM-1 008A provides 8 Class B (Style B) or 4 Class A (Style D) Initiating Circuits configurable for Alarm, Supervisory or Trouble zones. The DM-1008A occupies one module slot in the FX-2000 main or expander chassis. SGM-1004A Four Indicating Circuit Module The SGM-1004A provides 4 Class A/B (Style Z/Y) Indicating Circuits configurable as Silenceable or Non-Silenceable. Each Indicating Circuits is rated at 1.7 Amps. Each of the indicating circuits have individual signal silence inputs which are jumper selectable. The S•3M-1004A occupies one module slot in the FX-2033 main or expander chassis. RM-1008A Eight Relay Circuit Module The RM-1 008A provides the FX-2000 with 8 individual configurable relays per module. Each relay provides one Form C contt rated at 28 VDC @1 Amp (resistive load). The RM-1008A occupies one module slot in the FX-20J0 main or expander chassis. UDACT-300A Digital Alarm Communicator Module The UDACT-300A Digital Alarm Communicator Module allows the FX-2000 to transmit addressable point information to a central station. The UDACT-300A can be configured locally via the on-board keypad and the CFG-300 Configuration Tool or with a UIMA programming tool and a computer with an available serial or USB port. The UDACT- 300A occupies one module slot in the FX-2000 main or expander chassis. PR-300 Polarity Reversal/City Tie Module The PR-300 Polarity Reversal/City Tie Module provides the system with a supervised City Tie (24 VDC/200 mA max.) and Polarity Reversal connection (24 VDC (open circuit), 8 mA max. shorted)). The PR-300 mounts in the FX-2000 main chassis. CAT. 5910 1111 II i rco ni NOT TO BE USED FOR INSTALLATION PURPOSES. page 4 of 10 IE1IiIH1irrYmrn RAX-I048TZDS Programmable Zone LED Annunciator Module The RAX-1048TZDS Programmable Zone LED Annunciator Module provides 48 programmable bi- coloured LEDs. The RAX-1 048TZDS connects to the main panel or the RAX-LCD Shared Display when mounted remotely. The RAX-1048TZDS occupies one display position in the BB-1000 or 8B-5000 enclosures. FDX-008 Fan Damper Module The FDX-008 Fan Damper Module provides individually programmed circuits which can be used for fan or damper control. Each circuit has a slide-in label, .a three position selector switch, green run or open" LED and an amber "off or closed" LED. The three-position selector switch has a centre "auto" position, a left "off or close" position and a right "on or open" position. The FDX- 008 connects to the main panel or the RAX-LCD when mounted remotely. It uses MIX-M500CH for control of fans or dampers and two MIX-M501A for status. The FDX-008 occupies one display position in the 1313-1 000 or BB-5000 enclosures. IPS-2424DS Programmable Input Switches Module The IPS-2424DS Programmable Input Switches Module provides 24 programmable switches that can be configured for ancillary functions such as zone bypass or added common control functions. The switches operate in a toggle operation with one press for "on" and one press for "off'. The IPS-2424DS connects to main panel or the RAX-LCD when mounted remotely. The IPS-2424DS occupies one display position in the BB-1000 or BB-5000 enclosures. Electrical Ratings Current Consumption Model Standby Alarm FX-2003-6DS-16LED 230 mA 380 mA FX-2003-6DS FX-2003-I2DS 230 mA 380 mA FX-2017-I2ADS 230 mA 380 mA FX-2009-12DS 230 mA 380 mA ALC-198S/ALC-396S 35 mA 50 mA ALC-H16 35 mA 50 mA DM-1008A 80 mA 100 mA SGM-1004A 35 mA 150 mA RM-1008A 25 mA 150 mA PR-300 50 mA 300 mA UDACT-300A 40 mA 60 mA RAX-LCD 100 mA 150 mA IPS-2424DS 10 mA 144 mA FDX-008 10 mA 100 mA MGD-32 35 mA 1.6 Amps AGD-048 25 mA 2.4 Amps RAM-1032TZDS 50 mA 150 mA RAX-1048TZDS 15 mA 100 mA M 0 CAT. 5910 A/Aii, j rco ni NOT TO BE USED FOR INSTALLATION PURPOSES. page 5 of 10 Remote Annunciators Graphic Annunciator Driver Modules RAX-LCD Remote Shared Display The RAX-LCD Remote Shared Display is a remote annunciator that provides the same functions as the main display on the fire alarm control panel, less the 16 zone LEDs. In addition to operating as a remote annunciator, it can also be used as a driver module for standard LED annunciation or reduced zone annunciation (different from the main panel annunciation), graphic drivers programmed different from the main annunciators, programmable switch modules with a unique configuration and fan damper control also with a unique configuration. Each time a different type of annunciation configuration is needed an additional RAX-LCD is required. The RAX-LCD occupies one display position in the 1313-1 000 or BB-5000 enclosures. RAM-I O32TZDS Main Remote LED Annunciator The RAM-1032TZDS Main Remote LED Annunciator provides common annunciator functions and 32 points of LED annunciation. Each display point can be identified by the slide-in label that slides in beside the LED. The RAM-1032TZDS is equipped with sealed membrane- like buttons for Common Control functions. The RAM- 1032TZDS allows for the control switches to be disabled on a per function basis for areas that do not require certain common control functions to be remotely located from the fire alarm control panel. The RAM-i O32TZDS can be programmed differently than the main panel annunciator or remote RAX-LCD. All RAM-1 032TZDS remote annunciators on the system must be programmed the same. The RAM-i O32TZDS occupies one display position in the BB-1000 or BB-5000 enclosures. RAX-I048TZDS Adder Remote LED Annunciator The RAX-1048TZDS Adder Remote LED Annunciator provides an additional 48 points of LED annunciation. The RAX-1048TZDS is an expandible module that connects to the RAM-i O32TZDS. The RAX-1 O48TZDS occupies one display position in the 1313-1 000 or BB-5000 enclosures. MGD-32 Master Graphic Driver Module The MGD-32 Master Graphic Driver Module provides common control inputs for the common control switches such as System Reset, Signal Silence, Auxiliary Disconnect, Fire Drill, Lamp Test, Acknowledge and General Alarm. Any or all of these switch inputs can be used. There are supervised outputs for all of the support LEDs and the common control switches. The MGD-32 can also drive up to 32 supervised outputs. These output points are capable of driving LEDs or incandescent lamps. Mounts in a graphic annunciator wallbox or in the BB-5000 enclosures. External power supply required for incandescent lamps and lamp test. AGD-048 Adder Graphic Driver Module The AGD-048 Adder Graphic Driver Module can be used with the MGD-32 Master Graphic Driver modules, or if located remotely it must be connected and mounted with the RAX-LCD Shared Display. The AGD-048 will support an additional 48 supervised outputs. As with the master modules, the AGD-048 will support both LEDs and incandescent lamps. Mounts in a graphic annunciator wallbox or in the BB-5000 enclosures. NOTE: The combined total of RAM-I032TZDS and MGD-32 per system is eight. All RA-1000 Series annunciators or Graphic driver modules must have the zoned LED or graphic LED correlated to the same combination of addressable devices or hardwired zones. However the zoned LED annunciator on the FX-2000 main panel can be programmed differently from the annunciators mounted remotely. CAT. 5910 page 6 of 10 1411111,. M i rco m NOT TO BE USED FOR INSTALLATION PURPOSES. Enclosures DOX-1 024DS DOX-1 O24DSR UB-1024DS Universal Backbox The UB-1024DS Universal Backboxhouses the FX-2003- 6DS or FX-2003-12DS main control unit and provides space to mount up to I7AH batteries. A DOX-1 024DS(R) door is ordered separately. Dimensions (minus built-in trim ring): 26"H x 14.5"Wx4.2'D DOX-1024DS(R) Door The DOX-1024DS mounts on the UB-1024DS backbox. The door features the universal CAT-30 lock and is available in a white (DOX-1 024DS) or red exterior (DOX-1 024DSR). BB-5008 The BB-5008 is a lobby control centre enclosure which is capable of handling one FX-2009-12DS Large Main Control Unit which supports 2 internal annuciator modules such as the IPS-2424DS, FDX-008, RAX-1048TZDS, etc. In addition the BB-5008 allows for 4 footprints for mounting Audio Lobby Control modules, Fire Fighter's Lobby Control modules and FX-2000 Internal Anne nciator modules. The cabinet hold up to 24 AH batteries Door and Chassis hardware are ordered seperately. Dimensions: 36"H x 30W x 7"D Other Enclosures BB-1001: 9"H x 12.75W x 1.2"D BB-1002: 18"H x 12.75"Wx 1.2"D BB-1003: 26.4"H x 12.75"Wx 1.2"D BB-1008: 33"H x 22.5"Wx 1.25"D BB-1012: 45"H x 22.5"Wx 1.25"D BBX-1 O72ADS The BBX-1 O72ADS eiclosure is capable of handling one FX-2017-12ADS Mid-Size Main Control Unit as well as upto 24AH Batteries The cabinet features the universal CAT-30 lock and a removable door for easy installation and servicing. The cabinet is available in a white or red exterior (BBX-1 O72ARDS). Dimensions (minus built-in trim ring): 32.5"H x 25"W x 6.5"D BB-5014 The BB-5014 is a lcthy control cen:re enclosure which is capable of hanclir one FX-2009-12DS Large Main Control Unit which supports 2 internal annuciator modules such as the IPS-24240S, FDX-0C8, RAX-1048TZDS, etc. In addition the BB-5014 allows for 10 fcotpnnts for mounting Audio Lobby Control modules, Fire Fighter's Lobby Control modules and FX-2000 Internal Ar nunciator modules. The BB-5014 can also support a graphic annunciator in place of these modules. ThE cabinet hods Lpto24AH batteries. Door and Chassis hardware are ordered seperately. Dimensions: 60"H x 3C"W x 7"D £I1 CAT. 5910 i rco m NOT TO BE USED FOR INSTALLATION PURPOSES. page 7 0110 M500X Conventional Heat Sensors and Manual ~Pull Stations I_ 5 33 4th Floor -I — — — — — — — — — — — — — — — — — — — — — - Ir4IT4I II_1 l!PJIPEJI II IJ!;HEII BB-5008 enclosure c/w RAX-LCD, RAX-1048TZDS, IPS-2424DS and FDX-008. 2 Pair 33 Typical FX2000 Panel Wiring Class B (Style 4) I— ----- Graphic Annunciator Walibox c /w graphic BB-1001 enclosure annunciator, MGD-32 Master Graphic Donor - igg • c/w RAM1O32 LED Annunciator nodide and AGD048 dder crap modules — — — — — Signal Circuits 3&4 Ii I L 3rd Floor a — — — — — — — — — — — — — — — — — — — — — — - 24 VDC Riser Nun- _1_ Resettabte I Power BB-1 003 enclosure c/w 24 VOC I RAX-LCD, RAX-1048TZDS Riser __ ,1 and IPS-2424DS Resettable Power • i Conventional =Conventmn.ldevIcenj] 3 Hardwired Circuit #2 f r Indicating Conventional devices I 3 Data Signal Circuits _< 1 &2 t Loop - 2nd Floor - #1 _____ Conventional Hardwired Indicating Circuit #1 — — U I - I I — I — — — — — — — — — — — — — — — — — — — - Graphic Annunciator c/w AGD-048 modules FllMlI I I-- FX-2009-12DS Large Main Chassis in a BB-5014 enclosure c/w ECX-0012 Expander Chassis, RAX-1048TZDS, IPS-2424DS, FDX-008 and AGD-048 Includes DM-1008A Conventional Indicating Circuit Modules. External power supply is required for incandescent lamps and lamp test. 0 cr I M500M I M5OtM_l:is uae. M502M ,sraa M500S I;a 1 Pair for P5-485 1 Pair for 24 VOC //i Mj m c NOT TO BE USED FOR INSTALLATION PURPOSES. page 8OflO Ordering Information FX..2000 Standard Series .. : FX-2003-6DS-16LED Compact Main Control Unitdw one Intelligent Signaling Line Circuit, Four Style Z/Y (Class NB) Notification Appliance Circuits rated at 1.7 Amps each and a 4 line by 20 character back-lit LCD display with 16 LEDS for annunciation (DSPL-420-16TZDS). This display is functionally equivalent to the classic FX-2000 main display, but more compact adding in the 16 LEDs for annunciation in addition to all the standard functions.TheFX-2003-6DS-16LED is equipped with a 6 Amp Power Supply which charges 10-24AH batteries. The FX-2003-6DS-16LED provides space for 3 adder modules and 2 internal annunciator adder modules. Order UB-1024DS and DOX-1024DS(R) separately.. FX-2003-6DS Compact Main Control Unit c/w one Intelligent Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 x 20 Back-lit LCD display, 4 Class NB (Style Z/Y) Indicating Circuits (1.7 Amps each), a 6 Amp power supply and a backbox. Supports up to 16 Conventional Adder Mod- ules. Provides space for 3 Adder Modules and 2 internal annunciation modules. Order UB-1 024DS and DOX- 1 024DS(R) separately. . .... ,...,. .................. FX-2003-12DS Compact Main Control Unit c/w one Intelligent Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 x 20 Back-lit LCD display, 4 Class NB (Style Z/Y) Indicating Circuits (1.7 Amps each), a 12 Amp power supply and a backbox. Supports up to 16 Conventional Adder Mod- ules. Provides space for 3 Adder Modules and 2 internal annunciation modules. Order UB-1 024D5 and DOX-1024D5(R) separately. FX-201 7-1 2ADS Mid-Size Main Control Unit c/w one Intelligent Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 x 20 Back-lit LCD display, 4 Class NB (Style Z/Y) Indicating Circuits (1.7 Amps each) and a 12 Amp power supply. Supports up to 16 Conventional Adder Modules. Provides space for 17 Adder Modules and 3 Internal Annunciation modules. Mounts in the BBX- 1O72ADS enclosure. FX-2009-1 2DS Large Main Control Unit clw one Intelligent Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 x 20 Back-lit LCD display, 4 Class NB (Style Z/Y) Indicating Circuits (1.7 Amps each) and a 12 Amp power supply. Supports up to 16 Conventional Adder Modules. Pro- vides space for 9 Adder Modules and 3 Internal Annunciation modules. Mounts in the BB-5000 series enclosures. ECX-0012 Expander Chassis for the FX-2009-12DS c/w space to add up to 12 adder modules and 2 Internal Annunciation modules. Mounts in the BB-5000 series enclosures Adder Loop Controller Modules ALC-1 98S Single Loop IntelligentAnalog Loop Controller Module (99 Analog Sensors and 99AddressabIe Modules) ALC-396S Dual Loop Intelligent Analog Loop Controller Module (198 Analog Sensors and 198 Addressable Modules) ALC-H16 Hardwire Loop Controller Module. Supports 16 Conventional Hardwired Modules Adder Hardwire Modules. DM-1008A . itiat le Eight Class B (Style B) 014 Class A (Style D) Ining Circuit Module SGM-1 004A Four Class A/B (Style ZA') Indicating Circuit Module (Rated at 1.7 Amps per circuit) RM-1 008A Eight Relay Circuit Module c/w eight form C relays (Rated for 28 VDC @ 1 Amp max. per relay) Adder Auxiliary Modules UDACT-300A Digital Alarm Communicator Transmitter/Dialer Module PR-300 Polarity Reversal and City Tie Module Programmable Modules RAX- 1O48TZDS Programmable Zone LED Annunciator Module c/w 48 bi-coloured LEDs. IPS-2424D5 Programmable Input Switches Module c/w 24 selector switches and 24 bi-coloured LEDs FDX-008 Fan Damper Control Module c/w 8 programmable switches Remote Annunciators RAM-1O32TZDS MainAnnunciator Chassis c/w Common Control Features, Indicators and 32 Bi-Coloured LEDs RAX-1048TZDS AdderAnnunciator Chassis c/w 48 Bi-Coloured LEDs RTI-1 Remote Trouble Indicator Remote Shared Display Annunciators RAX-LCD Remote Shared Display LCD Annunciator c/w Display Queues and Common Controls Graphic Annunciator Driver Modules MG D-32 Master Graphic Driver Module c/w Fire Alarm Common Control Switch Inputs and 32 Supervised Outputs AGD-048 Adder Graphic 1.Driver Module c/w 48 Supervised Outputs CAT. 5910 flIti rco m NOT TO BE USED FOR INSTALLATION PURPOSES. page 9 of 10 Ordering Information cont'd Enclosures IUB-1024D5 Universal backbox for FX-2003-6DSIFX-2003-12DS. Order DOX-1024DS separately DOX-1024DS White door for U13-1024DS backbox DOX-1024DSR Red door for UB-1 024DS backbox BBX-1 O72ADS Black backbox enclosure for FX-2000 c/w removable door and CAT-30 lock and key. Houses one FX- 2017-12ADS Mid-Size Main Control Unit and up to 24 A batteries. Includes White door BBX-1 O72ARDS Black backbox enclosure for FX-2000 c/w removable door and CAT-30 lock and key. Houses one FX-2017-12ADS Mid-Size Main Control Unit and up to 24 A batteries. Includes Red door BB-5008 Lobby Control Centre Whllbox Enclosure. Supports 8 Module Footprints DOX-5008M White Metal Door for BB-5008 DOX-5008MR Red Metal Door for BB-5008 CCH-5008 Custom Mounting Kit for BB-5008. One required per BB-5008 BB-5014 Lobby Control Centre Wallbox Enclosure. Supports 14 Module Footprints DOX-5014M White Metal Door for BB-5014 DOX-5014MR Red Metal Door for BB-5014 CCH-5014 Custom Mountinq Kit for BB-5014. One required per BB-5014 NOT TO BE USED FOR INSTALLATION PURPOSES. wi:' Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 Web page: http://www.mircom.com U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Email: mail@mircom.com Distributed by: ISO 900 :2008 1\ REGISTERED CAT. 5910 Rev. 11 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1477:0111 Page 1 of 3 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (905) 660-4655 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Models FX-2000, FX-2000H, FX-2000N, and FX-4000 (Flex-Net) analog fire alarm control units. Non-coded, automatic, manual, local, auxiliary, remote station, central station, mass notification, waterfiow and sprinkler supervisory service. *Model FX-MNS-6000 system consisting of main control unit subassembly model FX-6000MNS-CH. Refer to the listees data sheet for detailed product description and operational considerations. System components: FX-2003-6, FX-2003-12, FX-20035-12, FX-2003-6D5, FX-2003-1 2D5: Main Chassis/Power Supply FX-2017-12A, FX-20175-12A, FX-2009-12, FX-20095-12: Main Chassis/Power Supply FX-2003-1 2H, FX-2003-6H: Main Chassis/Power Supply FX-2003-1 2N, FX-2009-1 2N, FX-201 7-1 2N, FX-2000ND, FX-2003-1 2NDS, FX-2009-1 2NDS, FX-2003-1 2XTDS: Main Chassis/Power Supply FX-2003-1 2XT, FX-2000MNS, FX-2003-1 2NXTDS, FX-201 7-1 2NDS: Main Chassis/Power Supply FX-4003-12N, FX-4003-12NXT, FX-4009-12N, FX-4017-12N: Main Chassis/Power Supply FX-2001-6K, FX-2001-6KU: One Analog Loop Fire Alarm Kits MD-654, MD-871, MD-871A, MD-770, MD-764, MD-757: Fire Alarm Module DSPL-2440, DSPL-244005, DSPL-420, DSPL-420D5, DSPL-420-16TZDS: Display Module MD-519: Annunciator Assembly QBC-5000N: Battery Charger MD-616, IPS-2424, lPS-2424D5, IPS-4848D5: Bypass Display DM-1008A, SGM-1004A, RM-1008A: Zone Adder Module PR-1 00, PR-300: Polarity Reversal/City Tie Module DACT-100, UDACT-300A: Dialer Module QX-5000: Voice Adder Module ECX-0012: Expander Chassis BBX-1024, -1072, -2000, BB-5008, -5014: Enclosure BBX-FXMNS, BBX-FXMNS (R), BBX-1024XT, BBX-1024XTR, BBX-1024D5(R): Enclosure RTI-1: Remote Trouble Indicator RAM-1032TZ, RAX-1048, RAX-1048TZ, RAXN-LCD, RAXN-LCDG, RAXN-4000LCD, *Rev. 3-30-22 DAL This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Listing No. 7165-1477:0111 Page 2 of 3 RAXN-4000LCDG: Annunciator Module RAM-1 032TZDS, RAM-1 016TZDS, RAM-1016TZ, RAX-i 048TZDS: Annunciator Module ALC-H16, -i98S, -396S, -127H, -254H, ALCN-792M, ALCN-792D, ALCN-792M1S0, ALCN-960M, ALCN-960M1S0, ALCN-960D, ALCN-4792M1S0: Loop Adder Module FDX-008, FDX-008Kl: Fan, Damper Control Module FDG-008: Fan Damper Driver Module FDS-008: Selection Control Panel GEO-MIRCOM: Fan Damper Display QAZT-5302, QAZT-5302DS, QAZT-5348DS: Interface Modules ANC-5000, ANC-4000: Audio Network Controller TNC-5000: Telephone Network Controller FNC-2000: Fire Network Controller QMP-5101 N, QM P-51 01 NV: Paging Module QMT-5302N, QMT-5302NV: Master Telephone Module PS-2040: Node Power Supply QMB-5000N: Card Cage FOM-2000-SP, FOM-2000-UM, FOM-CONN-SM, FOM-CONN-MM: Fiber Optic Module UDACT-300A: Dialer Module FX-LOC, FX-LOC (R): Local Operating Console INX-10A, lNX-10AC, INX-10ADS: Addressable NAC Booster Board & Chassis Open GN: Annunciator Software for FlexNet *System components for Model FX-MNS-6000 system: BBX-FXMNS-6000, QBB-6001 Enclosures, FX-6000MNS-CH Main Fire Alarm Chassis, QMP-6101NV Microphone Card, QMB-6000 Card Cage, QCC-6000 Communication Card, 70 Volt Amplifier QAD-6425-70, 25 Volt Amplifier QAD-6425-25, QPS-6650 Power Supply, ANC-6000 Audio Network Card. RATING: 120 VAC, 60 Hz; 240 VAC, 50 Hz *FX.6000MNS..CH Main Fire Alarm Chassis: 120V, 60 Hz, 6.1 A; 230V, 50 Hz, 3.13 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for-use with separately listed electrically and functionally compatible initiating and indicating devices. Suitable for high-rise applications when used with separately listed voice evacuation systems or *Fx_MNs..6000 systems. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm *Rev. 3-30-22 DAL This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed tj\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Listing No. 7165-1477:0111 Page 3 of 3 Evacuation Signal (for total evacuation) in accordance with NFPA 72. Refer to listee's Installation Instructions Manual for details. *Models FX-2000 and FX-2000H meets the requirements of UL 864, 9th Edition. *Models FX-2000N, FX-4000 and the Model FX-MNS-6000 system consisting of main control unit Subassembly model FX-6000MNS-CH meet the requirements of UL 864, 10th Edition. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Combined with 7170-1477:0119 Rev. 3-30-22 DAL This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct " operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division REMOTE SHARED DISPLAY RAX-LCD Features Provides exact functions as the FX-2000 main display Simple menu system with a directional keypad and switches for Enter, Menu Cancel and Info 4 line by 20-character LCD display Backlit display Expands with up to a total of 4 x RAX-1048TZDS or 6 x IPS-2424D5 Compatible with BB-1000 and BB-5000 Series enclosures. Power Consumption Amps (24V DC) Stand by 100 mA Alarm 150 mA Description The RAX-LCD shared display provides an exact replica (less 16 zone LEDs) of the main FX-2000 Fire Alarm Panel display at a remote location. It is equipped with a large 4 line x 20 character back-lit alphanumeric LCD display that uses a simple menu system complete with a directional keypad and switches for Enter, Menu Cancel anc Info. The display expands with up to a total of four RAX-1048TZDS Adder Annunciator or six IPS-2424DS Programmable Input Switches Modules. There are five types of enclosure available: the B13-1001D/R, BB-1002D/R, BB-1003D/R, 13131 OO8DIR, and BB-1 012D/R which can take 1,2,3,8,12 chassis respectively. It may also be mounted in the BB-5008 and the 1313-5014. @9 RAX-LCD 14 Line by 20 Character Remote Shared Display THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. US For complete and accurate technical information relating to performance, installation, testing and certification, refer to technical literature. This document 1. contains intellectual property of Mircom. The information is subject to change Intertek by Mircom without notice. Mircom does not represent or warrant correctness or completeness. CATALOG NUMBER 5351 Rev. 0 Canada 25 Interchange Way Vaughan, ON L4K 5W3 Telephone: (905) 660-4655 I Fax: (905)660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 I Fax Toll Free: (888) 660-4113 www.mircom.com CALIFORNIA DEPARTMENT.OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-1477:0107 Page 1 of 1 CATEGORY: 7120--ANNUNCIATORS LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (905) 660-4655 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Model RA-1000 remote multiplex annunciator panel. The main annunciator module provides indication for 32 zones. Each adder annunciator module provides indication for 48 additional zones. Unit includes main annunciator chassis RAM-1032 and adder annunciator chassis RAX-1048. Model RAX-LCD Liquid Crystal Annunicator, Model MGD-32 Master Graphic Driver chassis, Model MGDS-16/16 Main Display Annunicator Chassis and Model AGD-048 Adder graphic Driver chassis. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 20-29 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as annunciator panel for use with listee's separately listed compatible fire alarm control unit. Model RA-1 000 is suitable for use with listed compatible Model FA-1 000 (CSFM Listing No. 7165-1477:106) and FX-2000 (CSFM Listing No. (7165-1477:111) fire alarm control units. Model RAX-LCD is suitable for use with listed compatible Model FX-2000 fire alarm control unit (CSFM Listing No. (7165-1477:111). *Rev. 11-04-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division TELGUARD AMETEK TG-7 FS J1 ) LTE-A p L .WOR CIi1! E-l TG—S 0 c!L$ Lo,,dIc (Omo,l) Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories TG-PEM: Power & Expansion Module for powering the TG-7FS from-24V DC alarm panel; no need to have an electrician install a dedicated outlet. ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-O: External antenna. UL Listings Commercial Fire Commercial Burglary Residential 864 • control units & 365 • Police Station 985 Household fire accessories for fire connected burglar warning systems alarm systems alarm units and 1023 • Household burglar systems alarm systems 1610 • central station burglar alarm units; Line security servcies ULC Listings 5545 • Canadian household fire warning systems S304 • Canadian commercial burglary alarm systems S559 • Equipment for fire signal receiving centres and systems C0123 • Canadian household burglary alarm systems For the most current product specifications and UL Listings visit www.Telguard.com. SECURITY• SIGNALING '. .. IWM ELECTRONIC SECURITY C5/lJS s.,/ ASSOCIATION NFPA', Esnjtie ihg:c P-viner Connected LISTED INTERNATIONAL GeM by AT&T I Telguard, a Division of Telular corporation • 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 USA 800.229.2326 1 telguard.com • copyright @2019 Telguard, a Business Unit of AMETEK, Inc. • All Rights Reserved itsr IM ô COMMERCIAL FIRE PRODUCT FEATURES I' Certified for use on the AT&T LTE network for sunset-free installations. I" Meets UL 864 requirements for sole, primary or backup path communications. I' Minimizes false alarms by providing dual paths for self-tests. I'' Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LTE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2019 and earlier editions of NFPA 72, the TG-7FS LTE-A can serve as the sole communication path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-A because of the new five or sixty minute supervision modes. The TG-7FS LTE-A can also be installed as a backup path and upgraded to sole path at a later date. TG-7FS LTE-A P/N: TG7LAF01 TG7LAFO2 L. / J T h OR I * VV u ' CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0504 Page 1 of I CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3325 Cumberland Blvd, NE, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (800) 229-2326 Fax (678) 945-1651 Email: customerservice.telular@ametek.com DESIGN: Model TG-7F5 and TG-7UB Digital Cellular Radio Alarm Transmission Devices for fire alarm systems. Models are suffixed with -A for AT&T networks and -V for Verizon networks. Devices facilitate the use of the cellular network for the delivery of signals for commercial alarm panels. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 12/24VDC regulated (from panel) 12VAC (from plug-in adapter) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as digital cellular alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed fire alarm control panel in accordance with the installation instructions provided by the manufacturer. 02-16-22 DAL This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division AL1O42ULADA A Altronix®I Rev. 0721' .022 ALI042ULADA NAC Power Extender Altronix ALl O42ULADA is an extremely cost effective voltage regulated remote NAC Power Extender. It may be connected to any 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and providing auxiliary power to support system accessories. jJI I II.,LIIJI 10- Input Agency Listings Voltage 120VAC, 60Hz, 5A Two (2) Class Aor two (2) Class B inputs Two (2) NC dry contact trigger inputs Input Ratings (INPi and INP2): 8-30VDC 6.5mA max from FACP 12V 6.5mA, 24V 6.5mA from FACP Output Voltage 24VDC power-limited outputs Current 1 OA max. total alarm current 2.5A max. current per output Auxiliary Two auxiliary outputs rated at 1A each (1 A continuous, 1 A AC disconnect) Other Thermal and short circuit protection with auto reset Filtered and regulated outputs Programmable Supervised Indicating Circuit Outputs: Four (4) Class B, or Four (4) Class A, or Two (2) and Two (2) Class B Back-up Battery (not included) Type Sealed lead acid or gel type Failover Upon AC loss, instantaneous Supervision AC Failure Form "C" contacts Battery Form "C" contacts Indicators (LED) AC Power (Green) Input voltage is present DC Output (Red) Powered Logic Board (Red and Green) Output status UL !UL864 (Control Units and Accessories for Fire Systems) MEA NYC Department of Buildings Approved FM Factory Mutual Approved CSFM California State Fire Marshal Approved Special Features - 2-wire horn/strobe Sync mode allows audible notificaton appliances (horns) and t'isjal notification appliances (strobes) to be silenced/deactivated at the same time - Sync protocols include Potter/Amseco, Gentex®, System Sensor®, and Cooperwheelock® - Temporal Code 3, Steacy Mode, Input to Output Folloier Mode (maintains synchronizati:m of notification appliances circuit) - Compatible with 1 2VDC or 24VDC fire panels - Output loop supervision steered to Input 1 or Input 2. - Signal circuit trouble menory (helps identify intermittent loop problems) - Common trouble input ani output for external t0ub1e signals tie-in - Ground fault detection Physical and Environmental Dimensions (H x W x D) Enclosure: 18" x 14.5" xL.625" (457.2mm x 368.3mrr x 117.5mm Shipping: 21.75" x 18.25" x 5.75(552.5mm x 433.6mm xl 46.1 mm Enclosure accommodates ip to two () 1 2VDC/1 8AH bat:eries Weight (approx.) Product: 14.8 lb. (6.71 kg) Shipping: 19.15 lb. 8.69 kg) Temperature Operating: C'°C to 49CC (32°F to 120°F) Storage: - 20°C to 70°C (- 4°F to 15 BOF) Relative Humidity 65%+/-5% BTU/Hr. (approx.): 49 BTU/H -. Lifetime Warranty Altronix Corporation 1140 58th St I Brooklyn, NY 11220 USA phone: +1 718.567.8181 1 fax: +1718.567.9056 1 email: info@altronix.com I www.altronix.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-1335:0109 Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: AItronix140 58th Street, Bldg A, Ste 2N, Brooklyn, NY 11220 Contact: Gary Zatz (718) 567-8181 Fax (718) 567-9056 Email: garyz@altronix.com DESIGN: Models AL642UL-ADA, AL842UL-ADA, and AL1042UL-ADA Indicating Circuit Power Supply. Unit is a regulated 12 or 24 VDC power supply/charger used for supervision and expanded power driving capability of four notification appliance circuits. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 115 VAC primary, 12 or 24 VDC secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: The system must have the secondary power supply capable of operating the system for at least 24 hours battery standby) in the normal condition and followed by not less than 5 minutes of alarm as required by code. The battery circuit must be fully supervised. *Rev. 06-21-05KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct 1V' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Indoor Selectable Af - Output Low Frequency Sounders and Low Frequency. Sounder Strobes System Sensor L-Series audible visible notification products are rich with features guaranteed to maximize profits with lower current draw and modern aesthetics. Features The L-Series offers the most versatile and easy-to-use line of low 520 Hz ± 10% square wave tone, NFPA compliance frequency sounder and low frequency sounder strobes in the industry. With white and red plastic housings, listed for wall and Full candela range plus High/Low tone options to optimize current ceiling mounting, L-Series Low Frequency can meet virtually any draw for a wide variety of applications application requirement Compact, standard, and round ceiling options Field-selectable candela settings. Wall units: 15, 30, 75, 95, 110, 135, and 185. Ceiling units: 15, 30, 75, 95, 115, 150, and 177 Rotary switch for High/Low, Temp3, Temp4, and Continuous settings. Sounder-only models also offer a Coded setting. Plug-in design with minimal intrusion into the back box Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices (Direct replacement for HW/R-LF and P2RIWH-LF) Compatible with MDL3 sync module Sounders listed for ceiling and wall Round Sounder Strobes listed for ceiling and wall Updated modern aesthetics Agency Listings SIGNALING & FM <~> APPR1 0 LISTED S401 PR452768 Horns only: 7135-16530516 Horn/Strobes: 7125-165305/7 The low frequency sounder and low frequency sounder strobes were designed to address the NFPA 72 sleeping space requirements that require a low frequency notification appliance that ooerates within frequency range of 520 Hz ± 10% and is of a square wave tone. Like the entire L-Series product line they include a varieP' of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, L-Series uses a universal mounting plate with an onboard shorting spring, so installers can test wiring continui:'/ before the device is installed. Installers can also easily adapt devices to a suit a wce range of application requirements using field-selectable candEla settings, 24- volt operation, and a rotary switch for 520 Hz low frejency sounder tones. AVDS913-e2 • 11/02/2020 • Page 1 L-Series Specifications -. General L-Series low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit ° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor [-Series products shall operate between 32 and 120 degrees Fahrenheit (0°C to 49°C) from a regulated DC or full-wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings. Wall units: 15, 30, 75, 95, 110, 135, and 185. Ceiling units: 15, 30, 75, 95, 115, 150, and 177. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone and have a permanent marking on the housing that reads "520 Hz". Low Frequency Sounder The low frequency sounder shall be a System Sensor [-Series Model listed to UL 464 and shall be approved for fire protective service. The low frequency sounder and the Sync.CircuitTM MDL3 Module accessory, if used, shall be powered from a notification appliance circuit output and shall operate on a nominal 24 volts (includes fire alarm panels with built-in sync). When used with the Sync.Circuit Module MDL3, 24-volt rated notification appliance circuit outputs shall operate between 16,5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three or temporal four pattern, non- temporal (continuous) pattern and coded supply within the frequency range of 520 Hz ± 10% square wave tone. The low frequency sounder shall operate on a coded or non-coded power supply with high and low volume settings. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor [-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three or temporal four pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply with high and low volume settings. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes, the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Class B circuits or one Class A circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Freauencv Ranqe 520 Hz ± 10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 24 DC/FWR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/RNR1 Operating Voltage Range 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Dimensions Wall Sounder Strobe (including lens) 5.6" Lx 4.7W x 1.9" D (142 mm Lx 119 mm W x 49 mm D) Ceiling Sounder Strobe (including lens) 6.8" diameter x 2.47" high (173mm diameter x 62.7 mm D) Standard Wall Sounder 5.6" Lx 4.7W x 1.5" D(142 mm Lx 119 mm W x 38 mm D) Compact Wall Sounder 5.25" Lx 3.46" W x 1.5" D (133mm Lx 88mm W x 38mm D) Ceiling Sounder 6.8" diameter x 1.4" high (173mm diameter x 36mm high) Standard Wall Sounder with SBBRL/SBBWL Surface Mount Back Box 5.70" L x 4.8" W x 3.3" D (145 mm Lx 120 mm W x 87 mm D) Compact Wall Sounder with SBBGRL/SBBGWL Surface Mount Back Box 5.4" Lx 3.6" W x 3.0" D (137 mmL x 91 mm W x 76 mm D) Low Frequency Ceiling Sounder with SBBCRL/SBBCWL 6.9" diameter x 3.9" high (175mm diameter x 99mm high) Surface Mount Back Box Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. AVDS91 0.02 • 11/0212020 • Page 2 UL Current Draw and Sound Output Data ., . Sound Wall Sounder Strobe Current Draw (mA) Output Volume 1633VDC 16-33 FWR 16.33 V Pos Tone Settina lccil inrd 75cd q5rd llflcd 15ed 1R5cd I ISed 30cd 75cd 95cd hOed 135ed IRSed DC FWR 1 Temporal High 98 115 158 173 182 212 266 136 153 188 206 228 258 304 80 80 2 Temporal Low 98 102 141 162 173 202 255 150 150 176 194 216 242 280 76 76 3 Temporal High 98 108 137 151 178 202 252 200 198 169 188 212 242 290 80 80 4 Temporal 4 Low 102 104 122 136 163 187 237 176 174 154 173 197 227 275 76 76 5 Continuous High 141 158 198 216 234 264 305 190 207 249 268 289 321 368 80 80 6 Continuous Low 120 128 179 196 215 244 285 165 182 226 244 266 297 342 76 76 Sound Current Draw (mA) Output Ceiling Sounder Strobe (dBA) Volume 1633 VOC 16-33 FWR 16-33 V Pos Tone Settino 15cd 30cd 75cd 95cd llflcd 135cd 185edl l5cd 30cd 75cd 95cd hOed 135cd 185cd DC FWR 1 Temporal High 98 115 158 173 197 236 259 136 153 188 206 238 287 291 80 80 2 Temporal 3 Low 98 102 141 162 181 224 244 150 150 176 194 226 269 269 76 76 3 Temporal High 98 108 145 161 186 224 249 200 198 169 189 222 269 277 80 80 4 Temporal 4 Low 102 104 122 136 170 208 227 176 174 154 173 206 252 263 76 76 5 Continuous High 141 158 198 216 245 293 295 190 207 249 268 302 357 357 80 80 6 Continuous Low 120 128 179 196 225 271 273 165 182 226 244 278 330 330 76 76 Wall and Ceiling Sounder Volume Pos Tone Setting ______ Current Draw Sound Output (dBA) Reverberant 16-33 Volts 16-33 Volts DC FWR DC FWR 1 Temporal 3 High 108 150 80 80 2 Temporal 3 Low 78 76 76 76 3 Temporal 4 High 111 151 80 80 4 Temp6ral 4 Low 80 76 76 76 5 Continuous High 111 151 80 80 6 Continuous Low 80 76 76 76 7 Coded High 111 151 80 80 8 Coded Low 80 76 76 76 *NOTE. For coded tones, temporal coding must be provided by the NAC. If the NAC voltage is held constant, the sounder output will remain constantly on. Coded ratings provided are for continuous voltage. AVDS9I0-02 • 11/02/2020 • Page 3 L-Series Dimensions Wall LF Sounder Strobe Wall LF Sounder Ceiling LF Sounder Strobe Ceiling LF Sounder Red White Low Frequency Sounder Strobes P2RL-LF P2WL-LF LF Sounder Strobe, Wall PC2RL-LF PC2WL-LF [F Sounder Strobe, Ceiling Low Frequency Sounders HRL-LF HWL-LF LF Sounder, Wall HGRL-LF HGWL-LF Compact [F Sounder, Wall HCRL-LF HCWL-LF [F Sounder, Ceiling Accessories MDL3R MDL3W Sync.CircuitTM Module, UL-listed SBBRL SBBWL Surface Mount Back Box, Wall SBBCRL SBBCWL Surface Mount Back Box, Ceiling SBBGRL SBBGWL Surface Mount Back Box, Wall, Compact System Sensor® is registered trademark and Sync-Circuitlm is a trademark of Honeywell International. Inc. SYSTEM SENSOR" 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 02020 System Sensor. Product specifications subject to change soOhout ounce. Visit systemsensor.com for current product inforrrra metudingthe latest version of this data sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0516 Page 1 of 1 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Models HRL-LF, HWL-LF, HCRL-LF, HCWL-LF, HGRL-LF and HGWL-LF are low frequency horns. Horn models HRL-LF, HWL-LF, HGRL-LF and HGWL-LF may be mounted on the wall and are intended for indoor use only unless otherwise indicated. Horn models HCRL-LF, HCWL-LF may be mounted on the ceiling and are intended for indoor use only unless otherwise indicated. The standard horn models are the HRL-LF, HCRL-LF (red enclosure) and HWL-LF, HCWL-LF (white enclosure). The horn has an 8 position selectable tone settings. Models HGRL-LF and HGWL-LF perform the same as HRL-LF/HWL-LF and use a 'compact" housing which is intended to mount to a single gang electrical box. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: The models HRL-LF, HW-LF, HCRL-LF, HRWL-LF, HGRL-LF and HGWL-LF are rated 16-33 VdcNFWR (REGULATED 24 DC/FWR). INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, audibility ratings and UL label APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. For indoor dry use. Operating Temperature Range: 0°C to 49°C (32°F to 120°F). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 07-01-19 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V1' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0517 Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: Iisa.branthoneywell.com DESIGN: Models P2RL-LF and P2WL-LF are low frequency *wall horn/strobes. *Models PC2RL-LF and PC2WL-LF are low frequency ceiling horns/strobes. For these models, the horn has a 6 position selectable tone settings. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, date of manufacturer, model number, electrical ratings, audibility ratings, and UL label. APPROVAL: Listed as horn/strobes when used with separately listed compatible fire alarm control units. For indoor dry use. Operating Temperature Range: 0°C to 49°C (32°F to 120°F). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Revision 08-28-20 VVWV This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Indoor Selectable. Output Strobes and Horn Strobes for Ceiling Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95,115,150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only The Ssteri Sensor L.Series off Ers :he most versatile and easy-to-Lse lie of hor-is, strobes, and horn s:robes in the industry with lower cu-rent iraws and modern aest.-iet cs. With white and red plastic -lousings, wall ard ceiling moultirg options, System Sensor L-Seriee can meet virtually any applicEtioo requirement. The entira L-Serie.s prodici line of ceiling-mount strobes and horn strobes include a variety o features that crease their application versatil t, while simplifying installation. All ievices feature a plug-in design with minirrel intrusion into the back box, making installations fast and oolproof while virtually eliminatirg costly and time- consuming gounc faults. To furtl-e sirrplify nstallation, the L-Series uti:tzes a universal mountinç pla:e so installers can moun them to a wide array of back boxes. With an onboard slorting spring, installers can test wiring continuit'° be-.ore the device is installed. lnstalles car also easily adapt devices to a suit a wide range of application requirements using field-selec:ab e candela settings, automatic seectio-i of 12- :r 24-volt operation, and a rotary switch for horn tones witl two volume selections. Agency Listings SIGNALING LISTED APPROVED S5512 FM approved except 7125-16530504 S4011 for ALERT models 7135-1653:0503 3057383 AVDS8E8-02 • 12/01/2017 • Page 3 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit°' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize [-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V(24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17,5V (12 V nominal) or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86802 • 12/01/2017 • Page 2 UL Current Draw Data 1111, ____________ 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 11 5c 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3,lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 . 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data 8-17.5 18-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 2.47 (62.7 mm) 1.37" (34.8 mm) 6.83 di'' (173 rr 6.92' (175. 2.5- (64 mm) NO L-Series Dimensions A0545-00 A0546.00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box -01 01 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information - - cI Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications". 020 7 System Sens.r. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject tolcharge without notice, Visitsysterrrserrsoroore Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product oforreahoc including the dtestversion of this data sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: Iisa.branthoneywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ftV operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.branthoneyweIl.com DESIGN: System Sensor Indoor 2-wire and *4wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP12OKL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division SELECT SERIES INTELLIGENT SMOKE DETECTOR MIX-2351AP(A) I RAP(A) I TAP(A) MIX-235 lAP sensor mounted on a B300-6 base F07--r-Mr-Mr, The Select Series low profile smoke detectors are intelligent addressable plug-in detectors with point ID capability that enables each detector address to be set with rotary address switches providing exact device locations. Detector sensitivity is continually monitored and reported to the fire alarm control panel. These intelligent sensors utilize a state-of-the-art thermistor sensing circuit for fast response. Mircom's Advanced Protocol uses a high speed communication protocol that greatly increases the speed of communication between the intelligent devices. The modern design and expanded color options support contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The Select Series MIX-2351AP(A) photoelectric detector's re-designed optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The sensitivity of Select Series detectors can be programmed using the control panel software to suit the environment. The MIX-2351 RAP(A) photoelectric detector is also remote test capable for use with a duct smoke detector. The MIX-2351TAP(A) multi-sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 135°F (57°C) fixed temperature thermal sensing. Features Multi-criteria detection Designed to meet UL 268 7th Edition and UL 521 Listed. (MIX-2351 AP/TAP/RAP) Designed to meet CAN/ULC S529 Rev. 4 and CAN/ULC S530 listed. (MIX-2351APA/TAPA/RAPA) New modern profile Analog communications Low standby current Rotary address switches Dual LEDs for 360° visibility Expanded color kit options Specifications Height 2.0 inches (51 mm) eig installed in B300-6/ B300A-6 base 6.2 inches (156 mm) installed in B300-6/ B300A-6 base Diameter 4.1 inches (104 mm) installed in B501-WHITE/-IV base Shipping 3.4 oz (95 g) Weight Operating Photo: 32°F to 122°F (0°C to 50°C) temparature -4°F to 158°F (-20°C to 70°C) in duct applications Range Photo with Thermal: 32°F to 100°F (0°C to 38°C) Operating Humidity 10% to 93% non-condensing Range UL-Listed Velocity Photo/Photo with Thermal: 0 to 4,000 fpm (0 to Range 1219 m/minute) (suitable for installation in ducts) ;.. ....... - Voltage 15 to 32 VDC peak Range Operating Current 200 uA (one communication every 5 seconds with ©24VDC green LED blink on communication) Maximum 4.5 mA @ 24 VDC (one communication every 5 Current seconds with amber LED solid on) Maximum 2 mA @ 24 VDC (one communication every 5 Alarm Current seconds with red LED solid on) Ordering Information Model Description Color Intelligent Detectors MIX-2351AP Intelligent Photoelectric smoke detector - UL White MIX2351APA Intelligent Photoelectric smoke detector - ULC White MIX-2351 RAP Intelligent Photoelectric smoke detector, remote test capable, for use with duct smoke detectors - UL White MIX-2351 RAPA Intelligent Photoelectric smoke detector, remote test capable, for use with duct smoke detectors - ULC White MIX-2351TAP Intelligent Photoelectric smoke detector with Thermal - UL White MIX-2351TAPA Intelligent Photoelectric smoke detector with Thermal - ULC White Bases B501-WHITE 4" Flangeless mounting base - UL/ ULC White B501-IV 4" Flangeless mounting base - UL/ ULC Ivory B300-6 6" Flanged mounting base - UL White B300-6-IV 6" Flanged mounting base - UL Ivory B300A-6 6" Flanged mounting base - ULC White B300A-6-IV 6" Flanged mounting base - ULC Ivory B200SR-WH Standard Sounder Base - UL White B200SR-IV Standard Sounder Base - UL Ivory B200SRA-WH Standard Sounder Base - ULC White B200SRA-IV Standard Sounder Base - ULC Ivory B200SR-LF-WH Low-frequency Sounder Base - UL White B200SR-LF-IV Low-frequency Sounder Base - UL Ivory B224B1-WH Isolator Base - UL White B224Bl-IV Isolator Base - UL Ivory B224B1A-WH Isolator Base - ULC White B224B1A-IV Isolator Base - ULC Ivory B224RB-WH Relay Base - UL White B224RB-IV Relay Base - UL Ivory B224RBA-WH Relay Base - ULC White B224RBA-IV Relay Base - ULC Ivory Accessories CK300 Color Kit (includes cover and trim ring) - Pack of 10 White CK300-IV Color Kit (includes cover and trim ring) - Pack of 10 Ivory CK300-BL Color Kit (includes cover and trim ring) - Pack of 10 Black TR300 Trim Ring White TR300-IR Trim Ring Ivory RA100Z I Remote LED anunciator - UL Ivory RA100ZA Remote LED anunciator - ULC Ivory lilA,. M ircom Canada U.S.A. 25 Interchange Way 4575 Witmer Industrial Estates Vaughan, Ontario L4K 5W3 Niagara Falls, NY 14305 Telephone: (905) 660-4655 Toll Free: (888) 660-4655 Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 www.mircom.com THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. (Pam For complete and accurate technical information relating to D performance, installation, testing and certification, refer to technical literature. This document contains intellectual property of Mircom. The information is subject to change by Mircom without notice Intertek Mircom does not represent or warrant correctness or completeness. CAT. 5898 Rev. 0 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1477:0504 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (905) 660-4655 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Models MIX-2351AP, MIX-2351RAP, and MIX-2351TAP analog addressable photoelectric smoke detectors. Models are suitable for open air protection and duct installation with air velocity of 0 to 4000 ft/mm. Model MIX-2351 RAP has remote test capability in duct applications. Model MIX-2351TAP has an integral 135F fixed temperature heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed compatible System Sensor Models B501, 132101-P, B300-6, and B300-6-IS (CSFM Listing No. 7300-1653:0109), B2005 and B200SR (CSFM Listing No. 7300-1653:0213), B200S-LF and B200SR-LF (CSFM Listing No. 7300-1653:0238), B224B1 and B224RB bases (CSFM Listing No. 7300-1653:0126); Models DNR and DNRW housings (CSFM Listing No. 3240-1653:0209); and listee's separately listed compatible fire alarm control unit Model FX-3500 (CSFM Listing No. 7165-1477:0165). Refer to manufacturers Installation Instruction Manual for details. All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-1653:0508 4-12-21 \tNVV This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division DF-60059:1 • E-265 Intelligent Bases Standard, Relay, Isolator, Sounder, and Low-Frequency Sounder Bases : General To meet local code and application requirements, Fire-Lite offers standard 4" and 6" bases, as well as, specialty base designs includ- ing relay, isolator, sounder and low frequency sounder options for the new 365 Series of addressable detectors as well as previous generations. The standard 4" and 6" bases offer a plug-in detector base intended for use in intelligent systems, with screw terminals provided for power (+ and -), and remote annunciator connections. Communica- tion takes place over the power (+ and -) lines. The 4" base offers a compact design while the 6" base provides compatibility with a wider range of junction boxes. The specialty bases support application driven requirements. These bases employ a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface-mount boxes. The mounting plate enables pre-wiring of all connections to speed and simplify installation. Relay bases (B224RB-WH/B224RB-IV) provide one form-C contact relay for control of auxiliary functions, such as door closure and ele- vator recall. The relay can operate in two different modes (short and long delay). The activation time for the short delay is 60-100 milli- seconds, while the activation time for the long delay is 6-10 sec- onds. A shunt with pin headers, located on the base PC board, is used to set the delay timing. Isolator bases (B224B1-WH/8224B1-IV) allow the Signaling Line Cir- cuit (SLC) loop to operate under fault conditions created from a short circuit preventing an entire communication loop from being dis- abled. The base isolates the section of the loop containing the short circuit from the remainder of the circuit and automatically restores when the fault is corrected. Sounder and low frequency (-LF) sounder bases are designed for new and existing dwelling unit applications. They offer maximum flexibility in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. The low frequency sounder bases are designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent. Studies show that a lower fre- quency, centered around 520 Hz, is the most ideal to wake sleeping occupants, even those with mild to severe hearing loss. The B200SR sounder and -LF sounder bases (B200SR-WH/ B200SR-IV/B200SR-LF-WH/B200SR-LF-IV) are fully compatible with existing B501 BH Series sounder base installations. The device enables users to select one of two B501-supported tones (ANSI Temporal 3 or Continuous) through a jumper. The B200S sounder and -LF sounder bases (B200S-WH/B200S-IV/ B200S-LF-WH/B200S-LF-IV) adopt the same address as the detec- tor, but use a unique device type on the loop. The Fire Alarm Control Panel (FACP) can use that address to command an individual sounder - or a group of sounders - to activate. The command set from the FACP can be tailored to multiple event-driven tone outputs allowing selection of volume (75 or 85 dBA), tone (ANSI Temporal 3, ANSI Temporal 4, or March Time) and group. In addition, some FACPs will enable custom tone patterns. The B200S series sounder bases recognize the System Sensor synchronization protocol. This enables them to be used as a component of the general evacuation signal - along with other System Sensor AV appliances - when connected to a power supply or FACP output capable of generating the System Sensor synchronization pulses. (a Rre-LlTeALarms by Honeywell B300(A)-6 Standard B300(A)-6-IV Standard 6" Base (White) 6" Base (Ivory) B200S(A)-WH B200S-LF-WH Low- Sounder Base (White) Frequency Sounder Base (White) B501 -WHITE Flangeless B501-BL Flangeless 4" Base (White) 4" Base (Black) Specifications NOTE: Specifications applies to all model variants "A", "-BL' "-LF", "-IV", -WH, -WHITE. See Product Line Information for detailed model descrip- tion. Diameter B501-WHITE: 4(10.16cm) diameter. B300-6: 6.1" (15.49 cm) diameter. 13224131, B224RB: 6.2" (15.748 cm) diameter. B200S, B200SR: 6.875" (17.46 cm) diameter. Wire gauge: B224B1, B224RB: 14 to 24AWG. B300-6, B501, B200S, B200SR: 12to24AWG Temperature range: B224B1, B224RB, B2005, B200SR: 32°F to 120°F (0°C to 49°C). B300-6, B501: -4°F to 150°F (-20°C to 66°C). Humidity range: 10% to 93% RH, non-condensing. System temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. DF-60059:I .7/18/2018 - Page 1 of 3 However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tem- perature ranges and humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). Electrical Ratings FOR 8300-6 SERIES BASES: Operating voltage: 15 to 32 VDC Standby current: 170 pA maximum FOR B501 SERIES BASES: Operating voltage: 1510 32 VDC Standby current: 150 pA maximum FOR B200 SERIES BASES: External supply voltage: 16 to 33 VDC (FWR) Standby current: 500 pA maximum. Alarm current: B200S(A)(-IV)(-WH) - 35 mA maximum at high-volume setting - 15 mA maximum at low-volume setting B200S-LF(-IV)(-WH) High-volume setting: —70 mA maximum @ 33.0 VDC —90 mA maximum @ 24.0 VDC - 140 mA maximum @16.0 VDC B200S-LF(-IV)(-WH) Low-volume setting: —15 mA maximum @ 33.0 VDC —20 mA maximum @ 24.0 VDC —25 mA maximum @ 16.0 VDC B200SR(A)(-IV)(-WH) - 35 mA maximum B200SR-LF(-IV)(-WH) —65 mA maximum @ 33.0 VDC —90 mA maximum @ 24.0 VDC - 125 mA maximum @16.0 VDC SLC operating voltage: 15 to 32 VDC SLC standby current: See applicable sensor specification. Sound output: Greater than 85 dBA minimum; measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone) FOR B224B1, B224RB (A) (-IV) (-WH): Operating voltage: 15 to 32 VDC (powered by SLC) Standby ratings: <450 pA maximum @ 24 VDC Set time (B224RB(A)(-IV)(-WH) only): short delay 60-100 millisec- onds; long delay 6-10 seconds Reset time (B224RB(A)(-lV)(-WH) only): 20 milliseconds maximum Relay characteristics (B224RB(A)(-lV)(-WH) only): two-coil latch- ing relay; one Form-C contact; ratings (ULJCSA): 0.9 A @ 125 VAC, 0.9A @ 110 VDC, and 3.0 A @ 30 VDC Product Line Information INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: "-IV" suffix indicates Ivory color model. NOTE: "-BL" suffix indicates Black color model. NOTE: "-WH" and "-WHITE" suffix indicates White color model. 13300-6: White, 6" base, standard flanged low-profile mounting base; replacement for B21OLP. B300A-6: Same as B300-6, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10; replace- ment for B21OLPBP. 8300-6-lV: lvory,6" base, standard flanged low-profile mounting base. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed. B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. 6501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. B501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed. B224RB-WH: White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH: White, relay base, ULC listed. B224RBA-IV: Ivory, relay base, ULC listed. B224B1-WH: White, isolator detector base. B224Bl-IV: Ivory isolator detector base. B224BlA-WH: White, isolator detector base, ULC listed. 8224B1A-IV: Ivory isolator detector base, ULC listed. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses LiteSpeedTM protocol. B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses LiteSpeedTM protocol. B200SA-WH: Same as B2005-WH, ULC listed. B200SA-IV: Same as B200S-IV, ULC listed. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SRA-WH: Same as B200SR-WH, ULC listed. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listed. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the Page 2013— DF-60059:1 .7/18/2018 NFPA 72 sleeping space requirement. Intended for retrofit applica- Agency Listings and Approvals tions. The listings and approvals below apply to intelligent bases as noted. MOUNTING KITS AND ACCESSORIES In some cases, certain modules or applications may not be listed by TR300: White, replacement flange for B300(A)-6 bases certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. TR300-IV: Ivory, replacement flange for B300(A)-6-IV bases. ULIULC Listed: S911 RAIOOZ(A): Remote LED annunciator. 3 - 32 VDC. Mounts to a • FM Approved U.S. single-gang electrical box. For use with B501 (A) and B300(A)- 6. . • CSFM: 7300-1653:0109, 7300-1653:0126, 7300-1653:0213, 7300-1653:0238 M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. CK300: White, detector color kit. Pack of 10. CK300-IV: Ivory, detector color kit. Pack of 10. CK300-BL: Black, detector color kit. Pack of 10 Junction Box Selection Guide Base Models Single Gang Double g 3.5" Oct. 4.0' Oct. 4.0" Sq. with 3" 50 mm 60 mm 70 mm 75 mm mud ring B200S, B200SR Yes Yes Yes Yes Yes Yes No No No No 6501 No No Yes No No Yes Yes Yes Yes No B300-6 Yes No Yes Yes Yes Yes No No No No 13224131, B224RB Yes Yes Yes Yes Yes Yes No No No No NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. NOTE: Applies to all model variants "A' "-BL", "-LF' "-IV", "-WH' and "-WHITE". See Product Line Information for detailed model description. LiteSpeed TM is a trademark; and FireLite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2018 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. . Il All specifications are subject to change without notice. IN91191111111119 & MRNUFRCTOKINC QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 6994105. Country of Origin: Mexico www.firelite.com Page 3 of 3— DF-60059:l • 7/18/2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0109 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Models B401, B401 B, B401 R, B40I13R, B401 BR-750, B401 R-750, B402B, B404B, B404BT, B406B, B501, B501 B, 14506587-002, B501BH, B501 BHT, B401BH, B110LP, 13110RLP, B1IORLP750, 131121-P, BI14LP, B114LPBT, B1I6LP, 132101-P, B501-BL, B501-IV, *13501..wLdITE B300-6, B300-6-IV, B300-6-IS detector bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, *model number. *electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. *Refer to Manufacturers Installation Instruction Manual for details. NOTE: Formerly 7300-1209:128 *Rev 04-03-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division METAL FIRE ALARM STATION MS-710U Features Dual Action Key resettable Terminal connectors Gold plated SPST contacts Optional auxiliary contacts High-gloss red enamel finish Plastic breakrod Meets ADA5 lb. maximum manual-force Mounts on standard single gang box, Mircom's BB-700 surface metal backbox or BB-700WP weather proof backbox Mircom's MS-710U Manual Station povides manual fire reporting. This high quality, die-cast metal manual station is a dual action unit with SPST contacts and terminal strip connections. The normal open contact, which closes when the manual statior, is activated, is rated for 1 amp, 30 VDC. The contacts are gold plated to avoid the risk of corrosion. The MS-710U is available with a CAT-30 lock and keys and mounts on a standard single gang backbox, Mircom's BB-700 surface metal backbcx or BB-700WP weather proof backbox. The MS-710U Manual Station is listed for outdoor applications when used with the BB-700WP. The MS-71 OU Dual Action Manual Station is operated by pushing the bar labelled "PUSH BAR" and then pulling down the handle marked "PULL HANDLE". The MS-710U Manual Station is reset by opening the station with the key, placing the handle in the normal upright position and re-locking the staton. The manual station shall be Mircom's MS-710U. Operating instructions shall be in raised English lettering and the unit shall be constructed of high quality die- cast metal and finished in red enamel paint to provide quick identification. Pulling the handle shall initiate immediate operation of the alarm detection circuit. All manual fire alarm stations shall be installed as per the specific requirements outlined in the UL codes, as well as all other applicable national or local codes. Final acceptance is subject to the local authority having jurisdiction. approved APPROVED S7005 S7005 7150-1477:128 313-97-E CATALOG NUMBER 94 97 NOT TO BE USED FOR INSTALLATION PURPOSES. Vtircom reserves the right to make changes at any time without no-Ace in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Specifications Switch Rating: Manual Station Dimensions: Color: 1 Amp @3OVDC 0.1 Amp @ 125 VAC 4.9" H x 3.5" W x 2.0'D Red with raised white 13tters, white manual bar with raised black letters. Surface Mount Backboxes BB-700 Surface Mount Backbox Dimensions: 5" H x 3.6" W x 2.0" D BB-700WP Weatherproof Surface Mount Backbox Dimensions: 5" H x 3.6" W x 2.2" D Typical Wiring Diagram MS-71 OU FROM PREVIOUS STAT ON t. TO NET STATION fOR E'JJ OF LINE DEVICE ES: RE AS SHOWN SO THAT SUPERVISION CONNE:rIONS IS MAINTAINED. )UNT ST.;-ION TO 2" x 4"x 2 1/4" OUTLET BOX. VITCH RATING: ALL MODELS 1A @ 30VDC, A@ 125JAC U(IMUM 'IRE SIZE: No. 12AWG. Ordering Information Model Description MS-710U Dual Action Manual Station 1313-7C'O Series 700 Interior Surface Mount Bacftox, Red Finish BB-7C'OWP Series 700 Weatherproof Surface Mount Backbox, Fed Finish NOT TO BE USED FOR INSTALLATION PURPOSES. 11111,liz, Mi r com Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Te ephone: (05) 660-4655 F: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Distributed 3's: WEb page: http://www.mircom.com Email: maiI@mircom.com lS3 REGI 9OOi:2.))8 -..,.'-.'.. I_w) CAT. 5157 Rev. 6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1477:0128 Page 1 of I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (905) 660-4655 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Models MS-710APU, *MS..71oMpU MS-701U, -703U, 704U, -710U, -713U, -714U, 701ADU, -710ADU, -702U, -702ADU, -70IUP, -710UP, -703U(C), -704U(C), -713U(C), -714U(C), -705U, -715U,-706U(C), -716U(C), -707U(C), -717U(C) and -708 fire alarm boxes. These devices are manually actuated, single or dual action non-coded, fire alarm boxes. Units are to be mounted on standard outlet boxes or listee's Model BB-700 backbox for indoor use only and BB-700WP backbox for indoor and outdoor use. Models MS- 701 ID(U), -7021D(U) and -7101D(U) non-coded, indoor use only, fire alarm boxes. To be mounted on three-inch deep outlet boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC, IA, 125 VAC, 1A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, rating, and UL label. APPROVAL: Listed as fire alarm manual pull stations for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. Revision 08-14-20 WW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division ADVANCED PROTOCOL INTELLIGENT MONITOR MODULES MIX-M500AP SERIES P 44 Mircom -. --V 2 .jfl I ' FITT-r-Ty"O TTly Mircom's intelligent monitor modules are designed to meet a wide range of applications. The monitor modules provide an interface to contact devices, such as, manual stations, conventional smoke or heat detectors, waterfiow switches, and more. The monitor modules are addressed with easy-to-use rotary code switches. Mircom's Advanced Protocol (AP) devices use a high speed communication protocol that greatly increases the speed of communication between the intelligent devices. Mircom'sAdvanced Protocol uses a superior group polling method as well as an interrupt feature that provide for a faster response to an alarm condition. In addition, the Advanced Protocol allows for greater system capacity with support for up to 318 devices per SLC circuit. The AP devices are backwards compatible to operate in CLIP mode for legacy system applications. MIX-M500MAP Monitor Module Mircom's MIX-M500MAP monitor module is a standard- sized module that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. The MIX-M500MAP is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary decade switches. It provides either a 2-wire or 4-wire fault tolerant initiating circuit for normally open contact fire alarm, supervisory, or security devices. The module has a panel controlled LED indicator. Features Designed to meet a wide range of applications SEMS screws for easy wiring Panel controlled status LED (except MIX- M501 MAP) Rotary switches for direct-dial entry of address. Each unit can have address set for 01-159 for Advanced Protocol mode and 01-99 for CLIP mode (except MIX-M500X) Low standby current Mount in 4" square junction box MIX-M501 MAP Mini Monitor Module The MIX-M501 MAP is a miniature monitor module that supervises a Style B (Class B) circuit of dry-contact input devices. The small size of the module allows it to fit inside devices or junction boxes behind devices. The MIX-M501 MAP is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary decade switches. It provides a twowire initiating circuit for normally open contact fire alarm and security devices. MIX-M502MAP Zone Interface Module The MIX-M502MAP Zone Interface Module is a standard- sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit The module allows Mircom's intelligent panels to interface and monitor two- wire conventional smoke detectors. All two-wire detectors being monitored must be UL or ULC compatible with the module. The MlX-M502MAP is addressed through the communication line of an intelligent Mircom system. It transmits the status of one zone of two-wire detectors to the fire alarm control panel. Status conditions are reported as normal, open, or alarm. The interface module supervises the zone of detectors and the connection of the external power supply. APPROVED .'~ & @ 0 S5434 S5434 7300-14770167 CATALOG NUMBER cncn NOT TO BE USED FOR INSTALLATION PURPOSES. lircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. M500X Isolator Module The M500X Isolator Module is a standard-sized module that enables part of the communications loop to continue operating when a short circuit occurs on it. An LED indicator blinks in the normal condition and turns on during a short circuit condition. Specifications MIX-M500MAP Monitor Module Normal Operating Voltage 15 to 32 VDC Max. Alarm current (LED on) 5.0mA (LED on) Average Operating current evere1ti0h1 , 47k EOL EOL Resistance 47K Ohms Max. IDC wiring resistance 40 Ohms Maximum IDC Voltage 11 Volts Maximum IDC Current 400pA Temperature Range 32'F to 120F (0'C to 49C) Humidity 10% to 93% Non-condensing Dimensions 45 Hx4 Wx1 25 D MIX-M502MAP Zone Interface Module Normal Operating Voltage 15 to 32 VDC Maximum Alarm Current 5.1mA (LED on) Average Operating Current 400pA, 1 communication and 1 LED flash every 5 seconds, 3.9k EOL EOL Resistance 3.91K Ohms Max. IDC wiring resistance 125 Ohms IDC Supply Voltage Regulated DC Voltage 24 VDC power limited Ripple Voltage 0.1 Volts RMS maximum Current 90mA per module Temperature Range 32'F to 120'F (0'C to 49CC) Humidity 10% to 93% Non-condensing Dimensions 4.5 H x4'Wx 1.25 D The module will automatically restore the entire communications loop to the normal condition when the short circuit is removed MIX-M501 MAP Mini Monitor Module Nominal Operating Voltage 15-32 VDC Max. Alarm Current 600 uA Average Operating Current 400 pA, 1 communication every 5 seconds, 47k EOL EOL Resistance 47K Ohms Max. IDC Wiring Resistance 40 Ohms Maximum IDC Voltage 11 Volts Maximum IDC Current 400pA Temperature Range 32°F to 120°F (0°C to 49°C) Humidity 10% to 93% Non-condensing Dimensions 1.3' H x 2.75W x 0.65" D M500X Isolator Module Normal Operating Voltage - 15-32 VDC Stand-by Current 450 pA (not isolating) Maximum Current Draw 17mA (device in isolation) Temperature Range 32°F to 120°F (0°C to 49 °C) Humidity 10 to 93% Non-condensing Dimensions 4.5" H x4"Wx 1.25" D .rznflTIrnr.] jifT Model Description MIX-M500MAP Monitor Module MIX-M501 MAP Mini Monitor Module MIX-M502MAP Zone Interface Module MIX-M500X Isolator Module Add suffix 'A' for ULC listed model. NOT TO BE USED FOR INSTALLATION PURPOSES. hA1. M i rcom Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 Web page: http://www.mircom.com U.S A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Email: mail@mircom.com SO 9001:2008 RECOSIERED CAT. 5950 Rev. 1 DUAL MONITOR MODULE . - <.... MIX-M500DMAP Description The Dual Monitor Module is intended for use in intelligent, two wire systems. It provides two independent 2-wire initiating device circuits (lDC), at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices, or either normally open or normally closed security devices. The MIX-M500DMAP module connects to the SLC of a compatible fire alarm control panel. Mounts directly to 4-inch square electrical boxes. The box must have a minimum depth of 2 1/8 inches. [.r11rn(.]l iiFiT Features Provides two independent 2-wire initiating device circuits (IDC) Panel controlled status LED Rotary address switches Low standby current Mounts in standard 4" junction box Up to 99 modules can be connected to compatible panels in CLIP mode. Up to 159 modules can be connected to compatible panels in AP mode. Power Consumption Normal Operating Voltage Average Operating Current_ Current Draw 6.4 mA (LED on) Average Operating Current 750 l.JA (LED flashing) Model MIX-MSOODMAP Description ' AP Intelligent Dual Input Monitor Mondule MIX-M500MAP Monitor Module MIX-M501MAP Mini Monitor Module M IX-M5O2MAP Zone Interface Module MIX-M500X Isolator Module Add suffix "A" or ULC listed model. Canada 25 Interchange Way Vaughan, ON L4K 5W3 Telephone: (905) 660-4655 I Fax: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 1 Fax Toll Free: (888) 660-4113 www.mircom.com THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. For complete and accurate technical information relating to performance, WIN, "I installation, testing and certification, refer to technical literature. This document contains intellectual property of Mircom. The information is subject to change Intertek by Mircom without notice. Mircom does not represent or warrant correctness or completeness. CATALOG NUMBER 5902 Rev. 0 ADVANCED PROTOCOL CONTROL MODULES MIX-M500SAP/MIX-M500RAP Designed to meet a wide range of applications SEMS screws for easy wiring Panel controlled status LED Rotary switches for direct-dial entry of address. Each unit can have address set for 01-159 for Advanced Protocol mode and 01-99 for CLIP mode Low standby current Mount in 4" square junction box Mircom's intelligent control and relay modules are designed to meet a wide range of applications. The control modules can be used to supervise and activate Notification Appliances while the relay modules provide the system with dry contact outputs for activatey a variety of auxiliary devices. The control and relay modules are addressed with easy-to-use rotary code switches. Mircom's Advanced Protocol (AP) devices use a high speed communication protocol that greatly increases the speed of communication between the intelligent devices. Mircom'sAdvanced Protocol uses a superior group polling method as well as an interrupt feature that provide for a faster response to an alarm condition. In addition, the Advanced Protocol allows for greater system capacity with support for up to 318 devices per SLC circuit. The AP devices are backwards compatible to operate in CLIP mode for legacy system applications. MIX-M500RAP Relay Control Module The MIX-M500RAP Relay Control Module contains two isolated sets of Form-C contacts, which operate as a DPDT switch to provide the system with outputs for activating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. The module allows the control panel to switch these contacts on command. No supervision is provided for the relay contacts. MIX-M500SAP Supervised Control Module The MIX-M500SAP Supervised Control Module provides supervised monitoring of wiring to load devices that require an external power supply to operate, such as horns, strobes, or bells. It is capable of Styles Y and Z supervision. Upon command from the control panel, the MIX-M500SAP will disconnect the supervision and connect the external power supply across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned on. The external power supply is always relay isolated from the communication loop, so that a trouble condition on the power supply will never interfere with the rest of the system. Full analog measurement of the supervised wiring is transmitted back to the panel and can be used to detect impedance changes or other special test functions. APPROVED S5434 S5434 7300-14770167 CATALOG NUMBER NOT TO BE USED FOR INSTALLATION PURPOSES. lircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Specifications MIX-M500SAP Supervised Control Module Normal Operating Voltage 15 to 32 VDC Maximum Alarm Current 6.5mA (LED On) 400 pA max., 1 communica- Average Operating Current tion every 5 seconds 47k EOL resistor, 485 uA max.(Com- ___________________________ municating, NAG shorted). Maximum NAG Line Loss 14 VDC External Supply Voltage Maximum (NAG) Regulated 24V0C Maximum (Speakers) 70.07 V RMS, SOW For class B wiring system, the Max. NAG Current Ratings current rating is 3A; For class A wiring system, the current rating is 2A Temperature Range 32'F to 120'F (0'G to 49G) Humidity 10% to 93% Non-condensing Dimensions 4.5" H x 4" W x 1.25" D MIX-M500RAP Relay Control Module Normal Operating Voltage 15 to 32 VDC Maximum Alarm Current 6.5mA (LED on) Average Operating Current 300 pA, 1 communication every 5 seconds EOL Resistance Not used Temperature Range 32'F to 120'F (0C to 49'C) Humidity 10% to 93% Non-condensing Dimensions 4.5" H x 4" W x 1,25" D Relay Contact Ratings Current Rating Maximum Voltage Load Description Application 3 A 30 VDC Resistive Non-coded 2 A 30 VDC Resistive Coded 0,46 A 30 VDC (L/R= 20ms) Non-coded 0.9 A 125 VDC Resistive Non-coded 0.5A 125VAC (PF0.75) Non-coded 0,3A 125 VAC (PF0.35) Non-coded 0.7 A 70.7 VAC (PF0.35) Non-coded 0.2A 25 VAC (PF=0.35) Non-coded [I]rflT1rn(.] iii-it1 Model - Description MIX-M500RAP Relay Control Module MIX-M500SAP Supervised Control Module Add suffix "A"for ULC listed model. NOT TO BE USED FOR INSTALLATION PURPOSES. Ali,, M i rco mv Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 5951 Web page: http:I/www.mircom.com Email: mail@mlrcom.com CAT.jr-0 9001:2008 Rev 2 'u_WI iE(iSTEKE[ CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1477:0167 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (905) 660-4655 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Model MIX-M501 MAP mini monitor module, Models MIX-M500RAP relay module, MIX-M502MAP interface module, MIX-M500SAP control module and MIX-500MAP monitor module. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: 15-32 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control unit accessory modules for use with separately listed compatible control units. Refer to listee's Installation Instructions Manual for details. 11-13-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct AV' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Extension Rod AppUcatons - -- S. - -. OPTIONAL FEATURES POWDERCOATED FINISHES DTENSION AND MISALIGNMENT RODS SURFACE MOUNT BACK BOX TIME SAVING DRILL FIXTURE (FOR MOUNTING CATCH PLATE) RSG Security 2700 Junipero Ave Signal Hill CA, 90755 www.rsgsbcurity.com Tel: (562) 529-5100 Fax: (562) 529-5102 WIWI a ,0! 44 D DP( )FB OH JFPC DH ( )SPC OH: ( )FDBR DE )CPC1 DH( RPC (Brass Plated) (Fksh Mount) (Surface Mount) (Ground Mount) (Recessed) Description: OH series fire door holders are constructed of the finest materials and workmanship available. The door holder is made of durable die-cast metal and offered in a high luster powdercoat finish. Other features include standard dual voltage ac or dc inputs of 12 & 24V. 24 & 120V and 24 & 220V models While reducing stocking requirements, mc<el24120 draws a mere 020 ma. 0 24V00 lowering overall job costs (In large installations the cost savings can be substantia. Other features: single or double coil floor mounting, surf-ace mounting and direct wall mounting. No brackets are required. The. OH series door holder offes a new insta tun technique using an adhesive template assuring alignment without secondary adjustments. Accessories include extension and misalignment rods (various lengths) enabling parallelism between door and wall at distances greater than 12 inches anc misalignment over 4 inches. Aiding in installation is the aircraft quality OH drill that reduces instaJlahor) time and provides a near perfect alignment of catch- plate and armature - again-, lowering overall installation costs. Basic units otter superior holding force and low residual magnetism. Models 1224 and 24120 can operate at higher listed voltages producing holding forces in excess of lOOlbs, (45.kg) For special applications. Dual Voltage (rew 'ew shown) I \ i: STANDARD FEATURES VERY LOW CURRENT DRAW DUAL VOLTAGE INPUTS TERMINAL BLOCK CONNECTIONS HIGH HOLDING FORCE LOW RESIDUAL MAGNETISM MOUNTING HARDWARE & INSTRUCTIONS Extensions: Extension rods DHE1PC 1 atenc cHrome DIlL I B oass 0110-1.9- PC . :b extercon chmne DHEI 50 erasa 2.............nsc' c1ror on Oracs 81103PC 3 o'co tenson cororne 0140313 3 jn:H extenon brass OHL,\PC 4 ir:1 adusiabia extenco-' cHrome Di- 4 n aolUs1abteed ass Hardware: DIISBPC Swivel base chrome DN$BB Swivel hose brass DNCPC Catch p ate chrome 0I4CPS Catch plate brass Surface hack lu-rax chrome Surface baCk box brass Exieso' renchus Drlliing fixture Extension Wrenches tz Installation Tools: n fl I' Door HolderSwiv$bas —i PERFORMANCE DATA: Dc/mP 1224 I 12V 40 38 24V 24V 40 20 36 19 LL20V 20 24220 1 24V 19 22UV i - TERMINALS LB. KG CaL 136 30 13$ C&L 40 181 1 C, &'F-, , 3 158 C&i. 20 J 90 Iq 22 98 [*1l III ;llItWIii.J OH Door Holder F Flush Mount S Surface Mount R Recessed 6 Ground Mount PC Pcwdercoat Chrome B Brass Plated I Single Coil 2 Double Coil NOTE: #2 indicates double coil ground mount model NOTE: Holding forces listed in above table corresponds with shadid values, non shaded values are sUghty less. MODEL VOLTAGE DC/mA I AC/mA Terminals LB. j KG. 1224 24V 85 81 L C&L 1 75 1 34.0 2420 . 120V 1 100 1 C&L HIGH HOLDING FORCE/SPECIAL APPLICATIONS: To obtain performance vaius in table above apply high listed voltage to low voltage terminals (C & L). NOTE: This configuration can only be apped to models 1224 & 24120 ACCESSORIES Example: DH (24120) S) Oooi Holciec Moet/Voltage 1224, 24120. 24220 Mount St le Saiae, F u,h Gcapd, Recessed Chrome, 33ss DBR K',irelr 13ron7p) Coils 1,2 For ground mount model! ACCESSORIES: Extensions (ç) (I) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3550-1039:0100 Page 1 of 1 CATEGORY: 3550 -- DOOR CLOSER/HOLDERS/RELEASING DEVICES LISTEE: R5G2700 Junipero Ave., Signal Hill, CA 90755 Contact: Sheila Chem (562) 630-4684 Fax (562) 529-5100 Email: Sheila@rsgsecurity.com DESIGN: Models DH-12, -24, -120, -1224, -24120, and -24220 door closer/holders. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 12V, 24V, 120V, and 220V INSTALLATION: In accordance with listee's printed installation instructions and applicable codes and ordinances. The system is intended to be mounted in a horizontal position only. MARKING: Listees name, model number, rating and UL label. APPROVAL: Listed as door closer/holders for use with separately listed compatible detectors and fire alarm control units. *Rev. 06-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division