Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5810 VAN ALLEN WAY; ; FPC2022-0198
PERMIT REPORT city of Carlsbad Print Date: 07/15/2024 Job Address: 5810 VAN ALLEN WAY, CARLSBAD, CA 92008-7300 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121200300 Track #: Valuation: $1,100,924.00 Lot U: Occupancy Group: Project U: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Permit No: FPC2022-0198 Status: Closed - Finaled Applied: 10/25/2022 Issued: 12/19/2022 Finaled Close Out: 06/02/2023 Final Inspection: INSPECTOR: Salcedo, Felix Project Title: Description: SPEC TI SUITE -SPRINKLER TI (141 HEADS) Applicant: FPContractor: INDUSTRIAL FIRE SPRINKLER CO INC INDUSTRIAL FIRE SPRINKLER CO INC JAKE SANDAGE 3845 IMPERIAL AVE 3845 IMPERIAL AVE SAN DIEGO, CA 92113-1702 SAN DIEGO, CA 92113-1702 (619) 266-6030 (619) 266-6030 x109 FEE AMOUNT FIRE NFPA 13 or 13R System > 100 heads $774.00 FIRE Reinspection (per Inspection) $228.00 FIRE Reinspection (per Inspection) $228.00 Total Fees: $1,230.00 Total Payments To Date: $1,230.00 Balance Due: Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Page 1 of 7 NIKJNG4C l.l:II[.11u.7.M VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION The Viking VK3021 Quick Response Pendent Sprinkler is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Chart. LISTINGS AND APPROVALS c®us UL Listed: Category VNIV FM Approved: Classes 2017, 2015, 2043 Also approved for use in FM Approved vacuum dry sprinkler systems with a maximum supervisory vacuum pressure of -3 PSI (-207 mbar) CE: Standard EN12259-1, DOP_XT1A LPC1 LPCB Approved: reference no. 096m VdS Approved: Certificate no. G 422006 WARNING: Cancer and Reproductive Harm- wwwP65Warningsca.gov Refer to the Approval Chart and Design Criteria for requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 PSI (0.5 bar) Rated to: UL - 250 PSI (17 bar) WWP FM, CE, LPCB, and VdS - 175 PSI (12 bar) WWP Factory tested hydrostatically to 500 PSI (34.5 bar) Thread size: 1/2" NPT (15 mm BSPT) Nominal K-factor: 5.6 U.S. (80.6 metric*) Glass-bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass CW602N, UNS-C84400 or QM Brass Deflector: Stainless Steel UNS S30400 Pip Cap Shell - Stainless Steel UNS-S44400 Pip Cap Disc - Stainless Steel UNS-530100 Belleville Spring - Nickel Alloy Pip Cap Seal - Polytetrafluoroethylene (PTFE) Compression Screw: Brass CW612N, CW508L, UNS-C36000 or UNS-C26000 Shipping Cap: Polyethylene Bulb: Glass, nominal 3 mm diameter Ordering Information: (Refer to Table I and the current Viking List Price Book.) INSTALLATION Refer to appropriate NFPA, FM Global, and/or any other applicable installation standards. Risk of permanent damage. Over-tightening the sprinkler can cause permanent damage. > Tighten the sprinkler to a MAXIMUM torque of 14 ft-lbs (19 N-m). OPERATION During fire conditions, when the temperature around the sprinkler reaches its operating temperature, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. Form No. F_110720 Rev 22.1 February 22, 2022 Replaces Form No. F110720 21.3 (Added LPC....B and VdS details) Page 2 of 7 \iII(II41Gi® l.l:II[.q..•,YM VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers are available through a network of domestic and international distributors. See the Viking website for the closest distributor or contact Viking. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_110720 Rev 22.1 February 22, 2022 Figure 1: Wrenches Form No. F_110720 Rev 22.1 February 22, 2022 Page 30f7 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLE 1: ORDERING INFORMATION Instructions: Using the sprinkler base part number, (1) add the suffix for the desired Finish Size Sprinkler __ (2) add the suffix for the desired Temperature Rating. 1: Finishes 2: Temperature Ratings Description Suffix' Nominal Rating Bulb Color Max.Ambient Ceiling axTemperature3 Suffix Base Part NPT BSPT Number Inch mm 23870 1/2 Brass A 135 °F(57°C) _ Orange 100°F(38°C) A 23882 15 Chrome F 155 °F (68 °C) Red 100 °F (38 °C) B White Polyester 4,6 M-IW 175°F (79 °C) Yellow 150°F (65 °C) D Black Polyester 4,1 M-/B 200 °F (93 °C) Green 150 °F (65 °C) E ENT 4.5,6 JN 286 °F (141 °C) Blue 225 °F (107 °C) G OPEN -- -- Z Example: 23870MB/W = VK3021 with white polyester finish and 155 °F (68 °C) nominal temperature rating. This sprinkler is to be installed into an area with a maximum ambient temperature of 100 °F (38 °C) meaning if the area will experience temperatures above the maximum ambient rating, you shall use a higher temperature-rated sprinkler. Accessories Sprinkler Wrenches (see Figure 1): Standard Wrench: Part number 23559MB Recessed Socket Wrench: Part number 23560MB2 Sprinkler Cabinet: Up to 6 sprinklers: Part number 01724A 6-12 sprinklers: Part number 01725A Footnotes Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. Requires a 1/2" ratchet which is not available from Viking. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. UL Listed as corrosion resistant. FM Approved as corrosion resistant. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. UL Listed for 250 PSI (17 bar) WNP. 7116" (11 mm) Nominal Pipe Engagement 1/2" NPT I 15mmBSPT Figure 2: Sprinkler Dimensions Page 4 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com APPROVAL CHART Finish (es) (es) Viking Quick Response Pendent Sprinkler Temperature(s) 0 A1X KEY VK3021 K5.6 (80.6 metric) Escutcheon(s), If applicable Thread Size Listings and Approvals' Sprinkler Base NPT BSPT cULus FM Part Number1 Inch mm Approval Specification Maximum WWP Approval Specification Maximum WWP 23870 1/2 -- Al, A2X, 133Y 250 PSI (17 bar) Al, B2X, B3Y 175 PSI (12 bar) 23882 -- 15 Al, A2X, B3Y 250 PSI (17 bar) Al, B2X, 133Y 175 PSI (12 bar) Additional Listings and Approvals Maximum WWP 175 PSI (12 bar) CE LPCB1 VdS8 23870 1/2 -- Cl, D2X, D3Y Al, B2X, B3Y Al 23882 -- 15 Cl, D2X, D3Y Al, B2X, 133Y Al Approved Temperature Ratings A = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) and 286 °F (141 °C) B = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C = 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) and 286 °F (141 °C) 0 = 155 °F (68 °C), 175°F (79 °C), and 200 °F (93 °C) Approved Finishes I = Brass, Chrome, White Polyester 3,4 Black Polyester 1.4 , and ENT 4.1 2 = Brass, Chrome, White Polyester 3,4 and Black Polyester 3,4 3 = ENT 4,1 X = Installed with Viking Recessed Escutcheons Models E-1, E-2, E-3, NP-1, NP-2, and NP-3, or Viking Standard Surface Mounted Escutcheons Y = Installed with Viking Recessed Escutcheons Models E-1 and NP-1, or Viking Standard Surface Mounted Escutcheons Footnotes 1 Base Part number is shown. For complete part number, refer to Viking's current price schedule. 2 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available upon request with the same Listings and Approvals as the standard colors. cULus Listed as corrosion resistant. FM Approved as corrosion resistant. 6 CE: Standard EN1 2259-1, Declaration of Performance DOP_XT1A. LPCB Approved; reference no. 096m 8 Vd5 Approved; Certificate no. G 422006 Form No. F_110720 Rev 22.1 February 22, 2022 Page 5 of 7 CR VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) - N41KJNG* The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA - UL cULus Listing Requirements: The Viking VK3021 Quick Response Pendent Sprinkler is cULus Listed as indicated in Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers shall be followed. IMPORTANT: Always refer to Form Number F_091699 - Care and Handling of Sprinklers. Also refer to Form Number F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking Technical Data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. - DESIGN CRITERIA - FM FM Approval Requirements: The Viking VK3021 Quick Response Pendent Sprinkler is FM Approved as quick response Non-Storage Pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM Installation guidelines may differ from UL and/or NFPA criteria. IMPORTANT: Always refer to Form Number F_091699 - Care and Handling of Sprinklers. Also refer to Form Number F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking Technical Data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_110720 Rev 22.1 February 22, 2022 Page 6 of 7 "J IIIIs16i® i.i:IIEu.JM VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. Install the escutcheon inner ring onto the sprinkler threads. 2. Carefully slide the wrench** sideways around the protective cap then push upwards to engage with the sprinkler wrench flats. [iiI ow F 3. Install the sprinkler and escutcheon assembly into the pipe fitting. Be sure the escutcheon outer ring contacts the surface of the finished ceiling. Figure 3: Recessed Installation (with Recessed Socket Wrench) A 112" ratchet Is required (not available from Viking). 1. Install the escutcheon onto the sprinkler threads. 2. Carefully slide the wrench onto the sprinkler wrench flats. 3. Install the sprinkler and escutcheon assembly into the pipe fitting. Be sure the escutcheon contacts the surface of the finished ceiling. Figure 4: Installation (with Standard Wrench) Form No. F_110720 Rev 22.1 February 22, 2022 Ceiling opening size: Minimum: 2-5/16" (59 mm) Maximum: 2-1/2" (64 6" rn) Page 7 of 7 N II(JI*41G® l:II[.JM VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Models E-2, E-3, NP-2 or Models E-1 or NP-1 NP-3 Thread- Recessed Recessed Escutcheon 2-1/8' (54 mm) Ceiling opening size: 2-1/8" (54 mm) Escutcheon Minimum: 2-5/16" (59 mm) I (E-3 and NP-3 Outer rings L Maximum: 2-1/2" (64 mm) have larger diameters) Al 4 rr'- n 4 i'• -. 4 I Mi 13/16" I Mm. 15/16" Max. 1-7/16" (21 mm) Max. 1-3/4" (24 mm) (37 (44 mm) ___--.- Standard Surface-Mounted Escutcheon ure 5: Installation Dimensions with Viking Escutcheons Form No. F_110720 Rev 22.1 February 22, 2022 Replaces Form No. F_110720 21.3 (Added LPCB and VdS details) i 2iI r S?,i,ttRS !L' CORRECT INCORRECT (Original container used) (Placed loose in box) (Protected with caps) (Protective caps not used) CORRECT INCORRECT (Piping is in place at the (Sprinkler at floor level) ceiling) (Special installation (Designated wrench not wrenches) used) Page 1 of 4 KJIIG :1uJIIlI CARE AND HANDLING OF SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com SPRINKLERS ARE FRAGILE - HANDLE WITH CARE! General Handling and Storage: Store sprinklers in a cool, dry place. Protect sprinklers during storage, transport, handling, and after installation. Use the original shipping containers. DO NOT place sprinklers loose in boxes, bins, or buckets. Keep sprinklers separated at all times. DO NOT allow metal parts to contact sprinkler operating elements. For Pre-Assembled Drops: Protect sprinklers during handling and after installation. For recessed assemblies, use the protective sprinkler cap (Viking Part Number 10364). Sprinklers with Protective Shields or Caps: DO NOT remove shields or caps until after sprinkler installation and there no longer is potential for mechanical damage to the sprinkler operating elements. Sprinkler shields or caps MUST be removed BEFORE placing the system in service! Remove the sprinkler shield by carefully pulling it apart where it is snapped together. Remove the cap by turning it slightly and pulling it off the sprinkler. Sprinkler Installation: DO NOT use the sprinkler deflector or operating element to start or thread the sprinkler into a fitting. Use only the designated sprinkler head wrench! Refer to the current sprinkler tech- nical data page to determine the correct wrench for the model of sprinkler used. DO NOT install sprinklers onto piping at the floor level. Install sprinklers after the piping is in place to prevent mechanical damage. DO NOT allow impacts such as hammer blows directly to sprinklers or to fittings, pipe, or couplings in close proximity to sprinklers. Sprinklers can be damaged from direct or indirect impacts. DO NOT attempt to remove drywall, paint, etc., from sprinklers. Take care not to over-tighten the sprinkler and/or damage its operating parts! Maximum Torque: 1/2" NPT: 14 ft-lbs. (19.0 N-m) 3/4" NPT: 20 ft-lbs. (27.1 N-m) 1" NPT: 30 ft-lbs. (40.7 N-m) WARNING: cancer and Reproductive Harm- wwP65Wamingscagov A WARNING Any sprinkler with a loss of liquid from the glass bulb or damage to the fusible element should be destroyed. Never install sprinklers that have been dropped, damaged, or exposed to temperatures exceeding the maximum ambient temperature allowed. Sprinklers that have been painted in the field must be replaced per NFPA 13. Protect sprinklers from paint and paint overspray in accordance with the installation standards. Do not clean sprinklers with soap and water, ammonia, or any other cleaning fluid. Do not use adhesives or solvents on sprinklers or their operating elements. Refer to the appropriate technical data page and NFPA standards for complete care, handling, installation, and maintenance instructions. For additional product and system information Viking data pages and installation instructions are available on the Viking Web site at www.vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Replaces Form No. F_091699 Rev 16.1 (Added P65 Warning) Page 2 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com PROTECTIVE SPRINKLER SHIELDS AND CAPS General Handling and Storage: Many Viking sprinklers are available with a plastic protective cap or shield temporarily covering the operating elements. The snap- on shields and caps are factory installed and are intended to help protect the operating elements from mechanical damage during shipping, storage, and installation. NOTE: It is still necessary to follow the care and handling instructions on the appropriate sprin- kler technical data sheets* when installing sprinklers with bulb shields or caps. WHEN TO REMOVE THE SHIELDS AND CAPS: NOTE: SHIELDS AND CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Remove the shield or cap from the sprinkler only after checking all of the following: The sprinkler has been installed*. The wall or ceiling finish work is completed where the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operating elements. SHIELDS AND CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Figure 1: Sprinkler shield being removed from a pendent sprinkler. Figure 2: Sprinkler cap being removed from a pendent sprinkler. Figure 3: Sprinkler cap being re-moved from and upright sprinkler. HOW TO REMOVE SHIELDS AND CAPS: No tools are necessary to remove the shields or caps from sprinklers. DO NOT use any sharp objects to remove them! Take care not to cause mechanical damage to sprinklers when removing the shields or caps. When removing caps from fusible ele- ment sprinklers, use care to prevent dislodging ejector springs or damaging fusible elements. NOTE: Squeezing the sprinkler cap excessively could damage sprinkler fusible elements. To remove the shield, simply pull the ends of the shield apart where it is snapped together. Refer to Figure 1. To remove the cap, turn it slightly and pull it off the sprinkler. Refer to Figures 2 and 3. EM Refer to the current sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. Never install sprinklers that have been dropped, damaged, or exposed to temperatures in excess of the maximum ambient temperature allowed. * Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Page 3 of 4 NJIKJW*i :IUJIIll CARE AND HANDLING OF SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com àCAUTION CONCEALED COVER ASSEMBLIES ARE FRAGILE' TO ASSURE SATISFACTORY PERFORMANCE OF THE PRODUCT, HANDLE WITH CARE. Concealed Sprinkler and Adapter Assembly (Protective Cap Removed) Concealed Sprinkler and Adapter Assembly with Protective Cap Cover Plate Assembly (Pendent Cover 12381 shown) GENERAL HANDLING AND STORAGE INSTRUCTIONS: Do not store in temperatures exceeding 100 °F (38 CC). Avoid direct sunlight and confined areas subject to heat. Protect sprinklers and cover assemblies during storage, transport, handling, and after installation. -- Use original shipping containers. -- Do not place sprinklers or cover assemblies loose in boxes, bins, or buckets. Keep the sprinkler bodies covered with the protective sprinkler cap any time the sprinklers are shipped or handled, during testing of the system, and while ceiling finish work is being completed. Use only the designated Viking recessed sprinkler wrench (refer to the appropriate sprinkler data page) to install these sprinklers. NOTE: The protective cap is temporarily removed during installation and then placed back on the sprinkler for protection until finish work is completed. Do not over-tighten the sprinklers into fittings during installation. Do not use the sprinkler deflector to start or thread the sprinklers into fittings during installation. Do not attempt to remove drywall, paint, etc., from the sprinklers. Remove the plastic protective cap from the sprinkler before attaching the cover plate assembly. PROTECTIVE CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Page 4 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com USE THE FOLLOWING PRECAUTIONS WHEN HANDLING WAX-COATED SPRINKLERS Many of Viking's sprinklers are available with factory-applied wax coating for corrosion resistance. These sprinklers MUST receive appropriate care and handling to avoid damaging the wax coating and to assure satisfactory performance of the product. General Handling and Storage of Wax-Coated Sprinklers: Store the sprinklers in a cool, dry place (in temperatures below the maximum ambient temperature allowed for the sprinkler temperature rating. Refer to Table 1 below.) Store containers of wax-coated sprinklers separate from other sprinklers. Protect the sprinklers during storage, transport, handling, and after installation. Use original shipping containers. Do not place sprinklers in loose boxes, bins, or buckets. Installation of Wax-Coated Sprinklers: Use only the special sprinkler head wrench designed for installing wax-coated Viking sprinklers (any other wrench may damage the unit). Take care not to crack the wax coating on the units. For touching up the wax coating after installation, wax is available from Viking in bar form. Refer to Table 1 below. The coating MUST be repaired after sprinkler installation to protect the corrosion-resistant properties of the sprinkler. Use care when locating sprinklers near fixtures that can generate heat. Do not install sprinklers where they would be exposed to temperatures exceed- ing the maximum recommended ambient temperature for the temperature rating used. Inspect the coated sprinklers frequently soon after installation to verify the integrity of the corrosion resistant coating. Thereafter, inspect representative samples of the coated sprinklers in accordance with NFPA 25. Close up visual inspections are necessary to determine whether the sprinklers are being affected by corrosive conditions. Sprinkler Temperature Rating (Fusing Point) Wax Part Number TABLE 1 Wax Melting Point Maximum Ambient Ceiling Temperature' Wax Color 155 °F (68 °C) I 165 F (74 °C) 02568A 148 °F (64 °C) 100 °F (38 °C) Light Brown 175 °F (79 °C) 04146A 161 °F (71 °C) 150 °F (65 °C) Brown 200 °F (93 °C) 04146A 161 °F (71 C) 150 °F (65 °C) Brown 220°F(104°C) 02569A 170 °F(76°C) 150°F(65°C) Dark Brown 286 °F(141 °C) 02569A 170°F(76°C) 150F(65°C) Dark Brown 1 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Raving Jurisdiction. Refer to specific installation standards. Never install sprinklers that have been dropped, damaged, or exposed to temperatures in excess of the maximum ambi- ent temperature allowed. Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Replaces Form No. F_091699 Rev 16.1 (Added P65 Warning) Page 1 of 3 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION Viking fire sprinklers consist of a threaded frame with a specific waterway or orifice size and a deflector for distributing water in a specified pattern. A closed or sealed sprinkler refers to a complete assembly, including the thermosensitive operating element. An open sprinkler does not use an operating element and is open at all times. The distribution of water is intended to extinguish a fire or to control its spread. Viking sprinklers are available in several models and styles. Refer to specific sprinkler technical data pages for available styles, finishes, temperature ratings, thread sizes, and nominal'K-Factors for the particular model selected. LISTINGS AND APPROVALS Refer to the Approval Charts on the appropriate sprinkler technical data page(s) and/or WARNING: Cancer and Reproductive Harm- approval agency listings. • www.P65Warnings.ca.gov TECHNICAL DATA Pressure Ratings: Maximum allowable water working pressure is 175 psig (12 Bar) unless rated and specified for high water working pressure [250 psig (17.2 bar)]. Sprinkler Identification: Viking sprinklers are identified and marked with the word "Viking", the sprinkler identification number (SIN) consisting of "VK" plus a three digit number*, the model letter, and the year of manufacture. Available Finishes: Viking sprinklers are available in several decorative finishes. Some models are available with corrosion-resistant coatings or are fabricated from non-corrosive material. Refer to the sprinkler technical data page for additional information. Available Temperature Ratings: Viking sprinklers are available in several temperature ratings that relate to a specific temperature classification. Applicable installa- tion rules mandate the use and limitations of each temperature classification. In selecting the appropriate temperature classifica- tion, the maximum expected ceiling temperature must be known. When there is doubt as to the maximum temperature at the sprinkler location, a maximum-reading thermometer should be used to determine the temperature under conditions that would show the highest readings to be expected. In addition, recognized installation rules may require a higher temperature classifica- tion, depending upon sprinkler location, occupancy classification, commodity classification, storage height, and other hazards. In all cases, the maximum expected ceiling temperature dictates the lowest allowable temperature classification. Sprinklers located immediately adjacent to a heat source may require a higher temperature rating. K-Factors: Viking sprinklers are available in several orifice sizes with related K-Factors. The orifice is a tapered waterway and, therefore, the K-Factor given is nominal. Nominal U.S. K-Factors are provided in accordance with the 1999 edition of NFPA 13, Section 3-2.3. Refer to the specific data page for appropriate K-Factor information. Available Styles: Viking sprinklers are available for installation in several positions as indicated by a stamping on the deflector. The deflector style dictates the appropriate installation position of the sprinkler; it breaks the solid stream of water issuing from the sprinkler orifice to form a specific spray pattern. The following list indicates the various styles and identification of Viking sprinklers. UPRIGHT SPRINKLER: A sprinkler intended to be installed with the deflector above the frame so water flows upward through the orifice, striking the deflector and forming an umbrella-shaped spray pat- tern downward. Marked "SSU" (Standard Sprinkler Upright) or "UPRIGHT" Viking Technical Data may be found on on the deflector. PENDENT SPRINKLER: A sprinkler intended to be oriented with the deflec- The Viking Corporation's Web site at tor below the frame so water flows downward through the orifice, striking http://www.vikinggroupinc.com. the deflector and forming an umbrella-shaped spray pattern downward. The Web site may include a more recent Marked "SSP" (Standard Sprinkler Pendent) or "PENDENT" on the de- edition of this Technical Data Page. flector. CONVENTIONAL SPRINKLER: An "old style" sprinkler intended to be installed with the deflector in either the upright or pendent position. The deflector provides a spherical type pattern with 40 to 60 percent of the water initially directed downward and a proportion directed upward. Must be installed in accordance with installation rules for conventional or old style sprinklers. DO NOT USE AS A REPLACEMENT FOR STANDARD SPRAY SPRINKLERS. Marked "C U/P' (Conventional Upright/Pendent) on the deflector. Form No. F_080814 18.12.06 Rev 14.1.P65 Replaces Form No. F_080814 Rev 14.1 (Added P65 Warning.) Page 2o13 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com VERTICAL SIDEWALL (VSW) SPRINKLER: A sprinkler intended for installation near the wall and ceiling. The deflector provides a water spray pattern outward in a quarter-spherical pattern and can be installed in the upright or pendent position with the flow arrow in the direction of discharge. Marked 'SIDEWALL on the deflector with an arrow and the word "FLOW". (Note: Some vertical sidewall sprinklers can only be installed in the upright or pendent position—in this case, the sprinkler will also be marked "UPRIGHT" or "PENDENT".) HORIZONTAL SIDEWALL (HSW) SPRINKLER: A sprinkler intended for installation near the wall and ceiling. The special deflector provides a water spray pattern outward in a quarter-spherical pattern. Most of the water is directed away from the nearby wall with a small portion directed at the wall behind the sprinkler. The top of the deflector is oriented parallel with the ceiling or roof. The flow arrows point in the direction of discharge. Marked "SIDEWALL" and "TOP" with an arrow and the word "FLOW". EXTENDED COVERAGE (EC) SPRINKLER: A spray sprinkler designed to discharge water over an area having the maximum dimensions indicated in the individual listings. Maximum area of coverage, minimum flow rate, orifice size, and nominal K-Factor are specified in the individual listings. EC sprinklers are intended for Light-Hazard occupancies with smooth, flat, horizontal ceil- ings unless otherwise specified. In addition to the above markings, the sprinkler is marked "EC". QUICK RESPONSE (QR) SPRINKLER: A spray sprinkler with a fast- actuating operating element. The use of quick response sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction (AHJ) prior to installing. QUICK RESPONSE EXTENDED COVERAGE (QREC) SPRINKLER: A spray sprinkler designed to discharge water over an area having the maximum dimensions indicated in the individual listing. This is a sprinkler with an operating element that meets the criteria for quick response. QREC sprinklers are only intended for Light Hazard occupancies. The sprinkler is marked "QREC". FLUSH SPRINKLER: A decorative spray sprinkler intended for installation with a concealed piping system. The unit is mounted flush with the ceiling or wall, with the fusible link exposed. Upon actuation, the deflector extends beyond the ceiling or wall to distribute water discharge. The sprinkler is marked "SSP", "PEND", or "SIDEWALL" and "TOP". CONCEALED SPRINKLER: A decorative spray sprinkler intended for installation with a concealed piping system. The sprinkler is hidden from view by a cover plate installed flush with the ceiling or wall. During fire conditions, the cover plate detaches, and upon sprinkler actuation, the deflector extends beyond the ceiling or wall to distribute water discharge. The sprinkler is marked "SSP", "PEND", or "SIDEWALL" and "TOP". RECESSED SPRINKLER: A spray sprinkler assembly intended for installation with a concealed piping system. The assembly con- sists of a sprinkler installed in a decorative adjustable recessed escutcheon that minimizes the protrusion of the sprinkler beyond the ceiling or wall without adversely affecting the sprinkler distribution or sensitivity. Refer to the appropriate technical data page for allowable sprinkler models, temperature ratings, and occupancy classifications. DO NOT RECESS ANY SPRINKLER NOT LISTED FOR USE WITH THE ESCUTCHEON. CORROSION-RESISTANT SPRINKLER: A special service sprinkler with non-corrosive protective coatings, or that is fabricated from non-corrosive material, for use in atmospheres that would normally corrode sprinklers. DRY SPRINKLER: A special-service sprinkler intended for installation on dry pipe systems or wet pipe systems where the sprinkler is subject to freezing temperatures. The unit consists of a sprinkler permanently secured to an extension nipple with a sealed inlet end to prevent water from entering the nipple until the sprinkler operates. The unit MUST be installed in a tee fitting. Dry upright sprinklers are marked with the "B" dimension [distance from the face of the fitting (tee) to the top of the deflector]. Dry pendent and sidewall sprinklers are marked with the "A" dimension [the distance from the face of fitting (tee) to the finished surface of the ceiling or wall]. LARGE DROP SPRINKLER: A type of special application sprinkler used to provide fire control of specific high-challenge fire haz- ards. Large drop sprinklers are designed to produce an umbrella-shaped spray pattern downward with a higher percentage of "large" water droplets than standard spray sprinklers. The sprinkler has an extra-large orifice with a nominal K-Factor of 11.2. Marked "HIGH CHALLENGE" and "UPRIGHT". EARLY SUPPRESSION FAST-RESPONSE (ESFR) SPRINKLER: A sprinkler intended to provide fire suppression of specific high- challenge fire hazards through the use of a fast response fusible link, 14.0, 16.8, or 25.2 nominal K-Factor, and special deflector. ESFR sprinklers are designed to produce high-momentum water droplets in a hemispherical pattern below the deflector. This permits penetration of the fire plume and direct wetting of the burning fuel surface while cooling the atmosphere early in the development of a high-challenge fire. Marked "ESFR" and "UPRIGHT" or "PEND". INTERMEDIATE LEVEL/RACK STORAGE SPRINKLER: A standard spray sprinkler assembly designed to protect its operating element from the spray of sprinklers installed at higher elevations. The assembly consists of a standard or large orifice upright or pendent sprinkler with an integral upright or pendent water shield and guard assembly. Use only those sprinklers that have been tested and listed for use with the assembly. Refer to the technical data page for allowable sprinkler models. RESIDENTIAL SPRINKLER: A sprinkler intended for use in the following occupancies: one- and two-family dwellings with the fire protection sprinkler system installed in accordance with NFPA 13D; residential occupancies up to four stories in height with the fire protection system installed in accordance with NFPA 13R; and where allowed by the Authority Having Jurisdiction in resi- dential portions of any occupancy with the fire protection system installed in accordance with NFPA 13. Form No. F_080814 18.12.06 Rev 14.1.P65 Page 3 of 3 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Residential sprinklers have a unique distribution pattern and utilize a "fast response" heat sensitive operating element. They en- hance survivability in the room of fire origin and are designed to provide a life safety environment for a minimum of ten minutes. For this reason, residential sprinklers must not be used to replace standard sprinklers unless tested for and approved by the Authority Having Jurisdiction. In addition to standard markings, the unit is identified as "RESIDENTIAL SPRINKLER" or "RES". INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION Refer to the appropriate sprinkler technical data page(s). INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. IMPORTANT: Always referto Bulletin Form No. F..O91699 -Care and Handling of Sprinklers and the appropriate sprin- klergeneral care, installation, and maintenance guide.Viking sprinklers aretobe installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and alsowith the provisionsof governmental codes, ordinances, and standards, wheneverapplicable. The sprinkler technical data page may contain installation requirements specific for the sprinkler model selected. The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. Form No. F_080814 18.12.06 Rev 14.1.P65 Replaces Form No. F_080814 Rev 14.1 (Added P65 Warning.) Page 1 of 4 j 1(1 SPRINKLER GENERAL CARE, INSTALLATION, AND MAINTENANCE GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. DESCRIPTION - STANDARD RESPONSE, QUICK RESPONSE, EXTENDED COVERAGE, AND DRY SPRINKLERS Viking thermosensitive spray sprinklers consist of a small frame and either a glass bulb or a fusible operating element. Available styles include pendent, flush pendent, concealed pendent, upright, horizontal sidewall, vertical sidewall, or conventional, depending on the particular sprinkler model selected. Viking sprinklers are available with various finishes, temperature ratings, responses, and K-Factors to meet design requirementst. Used in conjunction with one of the corrosion-resistant coatings (for frame style sprinklers), the units provide protection against many corrosive environments. In addition, the special Polyester or PTFE coatings can be used in decorative applications where colors are desired. t Refer to the sprinkler technical data page for available styles, finishes, temperature ratings, responses, and nominal K-Factors for specific sprinkler models. LISTINGS AND APPROVALS Refer to the Approval Charts on the appropriate sprinkler technical data page(s) and/or approval agency listings. TECHNICAL DATA Specifications: WARNING: Cancer and Reproductive Harm- Refer to the appropriate sprinkler technical data sheet. www.P65Wamings.ca.gov Material Standards: Refer to the appropriate sprinkler technical data sheet. INSTALLATION NOTE: Take care not to over-tighten the sprinkler and/or damage its operating parts! Maximum Torque: 1/2" NPT: 14 ft-lbs. (19.0 N-m) 3/4" NPT: 20 ft-lbs. (27.1 N-m) 1" NPT: 30 ft-lbs. (40.7 N-m) Care and Handling (also refer to Bulletin - Care and Handling of Sprinklers, Form No. F_091699.) Sprinklers must be handled with care. They must be stored in a cool, dry place in their original shipping container. Never install sprinklers that have been dropped, damaged, or exposed to temperatures exceeding the maximum ambient temperature al- lowed (refer to the temperature chart on the sprinkler technical data page). Never install any glass-bulb sprinkler if the bulb is cracked or if there is a loss of liquid from the bulb. A small air bubble should be present in the glass bulb. Any sprinkler with a loss of liquid from the glass bulb or damage to the fusible element should be destroyed immediately. (Note: Installing glass bulb sprinklers in direct sunlight (ultraviolet light) may affect the color of the dye used to color code the bulb. This color change does not affect the integrity of the bulb.) Sprinklers must be protected from mechanical damage during storage, transport, handling, and after installation. Sprinklers subject to mechanical damage must be protected with an approved sprinkler guard. Use only sprinklers listed as corrosion resistant when subject to corrosive environments. When installing corrosion-resistant sprin- klers, take care not to damage the corrosion-resistant coating. Use only the special wrench designed for installing coated or recessed Viking sprinklers (any other wrench may damage the unit). Concealed sprinklers must be installed in neutral or negative pressure plenums only! Use care when locating sprinklers near fixtures that can generate heat. Do not install sprinklers where they could be exposed to temperatures exceeding the maximum recommended ambient temperature for the temperature rating used. Wet pipe systems must be provided with adequate heat. Sprinklers supplied from dry systems in areas subject to freezing must be listed dry sprinklers, upright, or horizontal sidewall sprinklers installed so that water is not trapped. For dry systems, pendent sprinklers and sidewall sprinklers installed on return bends are permitted, where the sprinklers, return bend, and branch line piping are in an area maintained at or above 40 °F (4 °C). Installation Instructions - Standard Spray Sprinklers Viking sprinklers are manufactured and tested to meet the rigid requirements of approving agencies. They are designed to be installed in accordance with recognized installation standards. Deviation from the standards or any alteration to sprinklers or cover plate assemblies after they leave the factory including, but not limited to: painting, plating, coating, or modification, may render them inoperative and will automatically nullify the approvals and any guarantee made by The Viking Corporation. Form No. F_080614 18.10.11 Rev 16.1.P65 Replaces Form No. F_080614 Rev 16.1 (Added P65 Warning.) Page 2 of 4 'I I 1(1 IGI'I SPRINKLER GENERAL CARE, INSTALLATION, AND MAINTENANCE GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Before installation, be sure to have the appropriate sprinkler model and style, with the correct K-Factor, temperature rating, and response characteristics. Sprinklers must be installed after the piping is in place to prevent mechanical damage. Keep sprinklers with protective caps or bulb shields contained within the caps or shields during installation and testing, and any time the sprinkler is shipped or handled. la. For frame-style sprinklers, install escutcheon (if used), which is designed to thread onto the external threads of the sprinkler. Refer to the appropriate sprinkler data page to determine approved escutcheons for use with specific sprinkler models. lb. For flush and concealed style sprinklers: Cut the sprinkler nipple so that the 1/z" or 3/4" (15 mm or 20 mm)* NPT outlet of the reducing coupling is at the desired location, and centered in the opening* in the ceiling or wall. *Size depends on the sprinkler model used. Refer to the sprinkler technical data page. Apply a small amount of pipe-joint compound or tape to the external threads of the sprinkler only, taking care not to allow a build-up of compound in the sprinkler inlet. NOTE: Sprinklers with protective caps or bulb shields must have the caps or shields kept on them when applying pipe-joint compound or tape. Exception: For domed concealed sprinklers, remove the protective cap for installation, and then place it back on the sprinkler temporarily.. Refer to the appropriate sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. DO NOT use the deflector or fusible element to start or thread the sprinkler into a fitting. Install the sprinkler onto the piping using the special sprinkler wrench only, taking care not to over-tighten or damage the sprinkler. For flush and concealed style sprinklers: the internal diameter of the special sprinkler installation wrench is designed for use with the sprinkler contained in the protective cap. Exception: For domed concealed sprinklers, remove the protective cap for installation, and then place it back on the sprinkler temporarily. Thread the flush or concealed sprinkler into the 1/2' or 3/4" (15 mm or 20 mm)* NPT outlet of the coupling by turning it clockwise with the special sprinkler wrench. *Thread size depends on the particular sprinkler model used. Refer to the sprinkler technical data page. C. Installation Instructions - Dry Sprinklers WARNING: Viking dry sprinklers are to be installed in the 1" outlet (for dry and preaction systems), or run of malleable, ductile iron, or Nibco CPVC* threaded tee fittings (for wet systems) that meet the dimensional requirements of ANSI B16.3 (Class 150), or cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125), even at branch line ends. The threaded end of the dry sprinkler is designed to allow the seal to penetrate and extend into the fitting to a predetermined depth. This prevents condensation from accumulating and freezing over the sprinkler seal. *NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-Bl. When selecting other CPVC fittings, contact Viking Technical Services. DO NOT install the dry sprinkler into a threaded elbow, coupling, or any other fitting that could interfere with thread penetration. Such installation would damage the brass seal. DO NOT install dry sprinklers into couplings or fittings that would allow condensation to accumulate above the seal when the sprinkler is located in an area subject to freezing. NEVER try to modify dry sprinklers. They are manufactured for specific 'A" or "B" dimensions and cannot be modified. The dry sprinkler must be installed after the piping is in place to prevent mechanical damage. Before installation, be sure to have the correct sprinkler model and style, with the appropriate "A" or "B" dimension(s), temperature rating, orifice size, and response characteristics. Keep sprinklers with protective caps or bulb shields contained within the caps or shields during installation and testing, and any time the sprinkler is shipped or handled. Exception: For concealed and adjustable recessed dry sprinklers, the protective caps and shields are removed for installation. To install the dry sprinkler, refer to the instructions below and the appropriate sprinkler technical data page for illustrated instruc- tions. Dry upright sprinklers must be installed above the piping, in the upright position only. When installing dry upright or plain barrel style vertical sidewall sprinklers on piping located close to the ceiling, it may be necessary to lower the sprinkler into the fitting from above the ceiling. When installing thy upright or plain barrel vertical sidewall sprinklers from below the ceiling, verify that the opening in the ceiling is a minimum 1-1/2" (38.1 mm) in diameter. For dry upright or plain barrel vertical sidewall sprinklers in the upright position: First, install the escutcheon (if used) over the threaded end of the sprinkler barrel. Slide the escutcheon past the external threads. NOTE: When installing the dry upright or plain barrel vertical sidewall sprinkler from above the ceiling, it will be necessary to install the escutcheon after lowering the threaded end of the sprinkler through the ceiling penetration. A. For all dry sprinklers: Apply a small amount of pipe-joint compound or tape to the external threads of the sprinkler barrel only, taking care not to allow a build-up of compound or tape over the brass inlet and seal. NOTE: Sprinklers with protective caps or bulb shields must be contained within the caps or shields before applying pipe-joint compound or tape. Form No. F_080614 18.10.11 Rev 16.1.P65 Page 3 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Refer to the appropriate sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. Install the dry sprinkler on the piping using the special dry sprinkler wrench only, while taking care not to damage the sprinkler. NOTE: Thread the sprinkler into the fitting hand tight, plus 1/2 turn with the dry sprinkler wrench. For adjustable standard and adjustable recessed dry pendent and sidewall sprinklers: Escutcheons can be installed after the sprinklers have been installed onto the piping. Refer to the appropriate sprinkler technical data page for escutcheon installation instructions and illustrations. D. Installation Instructions -Testing 4. After installation, the entire sprinkler system must be tested. The test must be conducted to comply with the installation stand- ards. Viking high pressure sprinklers may be hydrostatically tested at a maximum of 300 psi (20.7 bar) for limited periods of time (two hours), for the purpose of acceptance by the Authority Having Jurisdiction. Make sure the sprinkler is properly tightened. If a thread leak occurs, normally the sprinkler must be removed, new pipe-joint compound or tape applied, and then reinstalled. This is due to the fact that when the joint seal is damaged, the sealing compound or tape is washed out of the joint. Air testing [do not exceed 40 psi (2.76 bar)] the sprinkler piping prior to testing with water may be considered in areas where leakage during testing must be prevented. Refer to the Installation Standards and the Authority Having Jurisdiction. Remove plastic protective sprinkler caps or bulb shields AFTER the wall or ceiling finish work is completed where the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operating ele- ments. To remove the bulb shields, simply pull the ends of the shields apart where they are snapped together. To remove caps from frame style sprinklers, turn the caps slightly and pull them off the sprinklers. SPRINKLER CAPS OR BULB SHIELDS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Retain a protective cap or shield in the spare sprinkler cabinet. 5. For flush style sprinklers: the ceiling ring can now be installed onto the sprinkler body. Align the ceiling ring with the sprinkler body and thread or push it on (depends on sprinkler model) until the outer flange touches the surface of the ceiling. Note the maximum adjustment is 1/4" (6.35 mm). DO NOT MODIFY THE UNIT. If necessary, re-cut the sprinkler drop nipple as required. 6. For concealed sprinklers: the cover assembly can now be attached. Remove the cover from the protective box, taking care not to damage the cover plate assembly. Gently place the base of the cover plate assembly over the sprinkler protruding through the opening in the ceiling. Push the cover plate assembly onto the sprinkler until the unfinished brass flange of the cover plate base (or the cover adapter, if used) touches the surface of the ceiling. Refer to the applicable technical data sheet to determin the maximum adjustment available for concealed sprinklers. DO NOT MODIFY THE UNIT. If necessary, re-cut the sprinkler drop nipple. NOTE: If it is necessary to remove the entire sprinkler unit, the system must be taken out of service. See section 6. INSPECTIONS, TESTS AND MAINTENANCE and follow all warnings and instructions. 5. OPERATION Refer to the appropriate sprinkler technical data page(s). During fire conditions, the operating element fuses or shatters (depending on the type of sprinkler), releasing the pip cap and sealing assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appro- priate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. The sprinkler technical data page may contain installation requirements specific for the sprinkler model selected. The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. Form No. F_080614 18.10.11 Rev 16.1.P65 Page 4 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. 6. INSPECTIONS, TESTS AND MAINTENANCE NOTICE: Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. NOTICE: The owner is responsible for having the fire-protection system and devices inspected, tested, and maintained in proper operating condition in accordance with this guide, and applicable NFPA standards. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. A. Sprinklers must be inspected on a regular basis for corrosion, mechanical damage, obstructions, paint, etc. Frequency of inspec- tions may vary due to corrosive atmospheres, water supplies, and activity around the sprinkler unit. B. Sprinklers or cover plate assemblies that have been field painted, caulked, or mechanically damaged must be replaced im- mediately. Sprinklers showing signs of corrosion shall be tested and/or replaced immediately as required. Installation standards require sprinklers to be tested and, if necessary, replaced after a specified term of service. Refer to NFPA 25 and the Authority Having Jurisdiction for the specified period of time after which testing and/or replacement is required. Never attempt to repair or reassemble a sprinkler. Sprinklers and cover assemblies that have operated cannot be reassembled or re-used, but must be replaced. When replacement is necessary, use only new sprinklers and cover assemblies with identical performance char- acteristics. C. The sprinkler discharge pattern is critical for proper fire protection. Therefore, nothing should be hung from, attached to, or otherwise obstruct the discharge pattern. All obstructions must be immediately removed or, if necessary, additional sprinklers installed. D. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ or valve instructions. Prior to removing the system from service, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected area. 1. Remove the system from service, drain all water, and relieve all pressure on the piping. For frame-style sprinklers, use the special sprinkler wrench to remove the old sprinkler by turning it counterclockwise to unthread it from the piping. For flush and concealed style sprinklers: Remove the ceiling ring or cover plate assem- bly before unthreading the sprinkler body from the piping. Ceiling rings and cover plates can be removed ei- ther by gently unthreading them or pulling them off the sprinkler body (depends on the sprinkler model used). After the ceiling ring or cover plate assembly has been removed from the sprinkler body, place the plastic protective cap (from the spare sprinkler cabinet) over the sprinkler to be removed and then fit the sprinkler wrench over the cap. Then use the wrench to unthread the sprinkler from the piping. Exception: Domed concealed sprinklers are removed without the plastic cap. 3. Install the new sprinkler unit by following the instructions in section 4. INSTALLATION. Care must be taken to ensure that the replacement sprinkler is the proper model and style, with the correct K-Factor, temperature rating, and response character- istics. A fully stocked spare sprinkler cabinet should be provided for this purpose. For flush or concealed sprinklers: stock of spare ceiling rings or cover plates should also be available in the spare sprinkler cabinet. E. Place the system back in service and secure all valves. Check for and repair all leaks. Sprinkler systems that have been sub- jected to a fire must be returned to service as soon as possible. The entire system must be inspected for damage, and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combustion or high ambient temperatures, but have not operated, should be replaced. Refer to the Authority Having Jurisdiction for minimum replacement requirements. 7. AVAILABILITY Viking sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_080614 18.10.11 Rev 16.1.P65 Replaces Form No. F_080614 Rev 16.1 (Added P65 Warning.) Page 1 of 1 4 REGULATORY AND HEALTH J II(II1G ® WARNINGS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Regulatory and Health Warnings applying to materials used in the manufacture and construction of fire protection products are provided herin as they relate to legally mandated jurisdictional regions. A WARNING STATE OF CALIFORNIA, USA Installing or servicing fire protection products such as sprinklers, valves, piping etc. can expose you to chemicals including, but not li- mited to, lead, nickel, butadiene, titaninum dioxide, chromium, carbon black, and acrylonitrile which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov I WARRANTY TERMS AND CONDITIONS For details of warranty, refer to Viking's current list price schedule at www.vikinggroupinc.com or contact Viking directly. Form No. F_111218 18.11.15 Rev 18.1 New Bulletin Page lofi CR XTI Sprinkler and NIKJNG4 11J!Ill XG Guard Assemblies The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com INTRODUCTION The purpose of this bulletin is to inform users of proper XG Guard usage for the Model XT1 Sprinklers. The XG Guard assemblies are specifically listed and approved for use on Model XII Sprinklers: no other guard assemblies should be used. [A WARNINGI Viking sprinklers are manufactured and tested to meet the rigid requirements of the approving agency. The sprinklers are designed to be installed in accordance with recognized installation standards. Deviation from the standards or any alteration to the sprinkler after it leaves the factory including, but not limited to: unlisted accessories, painting, plating, coating, or modification, may render the sprinkler inoperative and will automatically nullify the approval and any guarantee made by The Viking Corporation. Refer to the Authority Having Jurisdiction prior to installation. GENERAL INFORMATION: A potential product performance issue may exist when listed products are combined with unlisted product(s) that have not been evaluated together by a recognized approval laboratory. With the development of new products and existing products, it is extremely important to correctly match a sprinkler with a sprinkler guard. Please refer to the appropriate manufacturer's technical literature or call Viking Technical Services at 877-384-5464. Model XTI sprinklers are specifically listed and approved with XG Guard. The XG Guard, part number 22931, is listed and approved for use with the following XTI sprinklers: VKIOOI, VKIO2I, VK3001, VK3021, VK2002, VK2022, VK3502, VK3522, VK2001, VK2021, VK3501, VK3521. NOTE: Image is represetative only. Actual product appearance may vary. Listed and Approved XG Guard/XTI Sprinkler Assembly Unlisted GuardIXT1 Sprinkler Assembly Activation r N\element T.hinOe blocked INC- IL I Form No. F_091119 19.09.11 Rev 19.1