Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5923 FARNSWORTH CT; ; FPC2023-0193
PERMIT REPORT CL'City of Carlsbad Print Date: 06/14/2024 Job Address: 5923 FARNSWORTH CT, CARLSBAD, CA 92008-7303 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2120700800 Track 1: Valuation: $0.00 Lot #: Occupancy Group: Project t: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2023-0193 Status: Closed - Finaled Applied: 11/08/2023 Issued: 05/21/2024 Finaled Close Out: 06/14/2024 Final Inspection: INSPECTOR: Maldonado, Adalmira Cheung, Nathaniel Project Title: Description: GOOD FEET - REVISED PLANS FOR ADDITION OF AN EXTERNAL FIRE ALARM CELLULAR COMMUNICATOR (2 DEVICES) FPContractor: JOHNSON CONTROLS SECURITY SOLUTIONS LLC P0 BOX 3042 BOCA RATON, FL 33431-0942 (561)226-8210 FEE AMOUNT FIRE Plan Review (per hr - Regular Office Hours) $170.00 FIRE Sprinkler Monitoring System $482.00 Total Fees: $652.00 Total Payments To Date: $652.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov REC'EIVED1 ' FPC2023-0193 Project Information 5923 FARNSWORTH CT GOOD FEET - REVISED PLANS FOR ADDITION OF AN EXTERNAL FIRE ALARM CELLULAR COMMUNICATOR (2 DEVICES) 2120700800 5/24/2024 FPC2023-01 93 MAY 2 4 2024 C AiL BAD FIRE DFIRJI mit Applicatk Good Feet Project Name Project Address 5923 Farnsworth Ct Carlsbad, CA 92008 Fire Alarm Control/Cell Dialer Scope of Work Suite # Associated Building Permit # (if applicable) M260 bif'? 4WVo%AS4 LI Fire Sprinkler System: Number of risers Number of Heads LI Underground: Number of Hydrants Fire Alarm LI Sprinkler Monitoring LI New System El Tenant Improvement Other: Cell Dialer Contractor Information Johnson Contols Company Name Address 3870 Murphy Canyon RD Applicant Name Kristin Byrne Phone 619-936-6881 San Diego CA 92123 City State Zip Email kristin.byrne@jci.Com 977249 Contractors State License Contractor License Number and Type City Business License Number BLOS00831 3-08-2020 Signature Active Exp. Date 5/23/24 Date For questions about the application submittal package please email Fire Permit Technician Fire & Life Safety Division 1 1635 Faraday Ave I Carlsbad, CA 92008 1 442-339-2665 1 www.carlsbadfire.org DF-52416:D • A3-20 MS-5UD(E)/MS.1 OUD(E) Series Five Zone Fire Alarm Control Panel Ten Zone Fire Alarm Control Panel 8 Fire Lrre0ALarms by Honeywell aC General The MS-51JID-3(E) is a five-zone FACP (Fire Alarm Control Panel) and theMS101JID7(E) I atenpFACP These con- trol panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor's microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 10UD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to the FireLite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. New options include a UL listed printer, PRN-6F and FireLite's IPDACT Internet Monitoring module. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD per- mit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: The MS-5UD-3E and MS-10UD-7E offers The same fea- tures as the MS-5UD-3 and MS-10UD-7 but allow connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and the 240 VAC versions of these panels. NOTE: For ULC-listed models, see DF-60440. Features Listed to UL Standard 864, 9th edition. Built-in DACT (Digital Alarm Communicator/Transmitter). Style B (Class B) IDC (Initiating Device Circuit) - MS-5UD-3 - five lDCs. - MS-i OUD-7 - ten lDCs. Style Y (Class B) NAC (Notification Appliance Circuit) - spe- cial application power - MS-5UD-3 - four NACs. - MS-1 OUD-7 - four NACs. Notification Appliances may be programmed as - Silence Inhibit. - Auto-Silence. - Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices. - Selective Silence (horn-strobe mute). - Temporal or Steady Signal. - Silenceable or Nonsilenceable. Optional CAC-5X Style Z (Class A) Converter Module for NACs and IDCs (2 required for MS-i OUD-7). Form-C Relays for Alarm, Trouble and Supervisory - Con- tact Ratings 2.0 A@ 30 VDC or 0.5 A © 30 VAC (resistive). 3.0 A total system current for MS-5UD-3. 7.0 A total system current for MS-i OUD-7. Optional Dress Panel DP-51050 Optional Trim Ring TR-CE for semi-flush mounting. 24 volt operation. Low AC voltage sense. Alarm Verification. PAS (Positive Alarm Sequence). Automatic battery trickle charger. Up to eight ANN-BUS annunciators: - Optional 8 zone Relay Module ANN-RLY. - Optional LED Annunciator Module ANN-LED, - Optional Remote Annunciator ANN-80. - Optional Remote Printer Gateway ANN-S/PG. - Optional LED Annunciator Driver ANN-I/O. Optional 4XTMF module (conventional reverse polarity/city box transmitter). PROGRAMMING AND SOFTWARE: Can be programmed at the panel with no special software or additional equipment. Programmable Make/Break Ratio. Upload/Download (local or remote) of program and data via integral DACT. DF-52416:O.07/26/2010—Page 1 of 4 Door = 19.26" (48.92 cm) Backbox = 19.0° (48.26 cm) USER INTERFACE: Built-in DACT (Digital Alarm Communicator/Transmitter). Integral 80-character LCD display with backlighting and keypad. Real-time clock/calendar with automatic daylight savings adjustments. ANN-BUS for connection to remote annunciators. Audible or silent walk test capabilities. Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS FIRE ALARM (red) SUPERVISORY (yellow) TROUBLE (yellow) AC POWER (green) ALARM SILENCED (yellow) CONTROL BUTTONS ACKNOWLEDGE ALARM SILENCE SYSTEM RESET (lamp test) DRILL Terminal Blocks AC Power —TB1: MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, 1.00 A. MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, 3.80 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50/60 HZ, 2.20 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Supervised, nonpower-limited. Battery (sealed lead acid only) - J12: Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 A. Supervised, nonpower-limited. Maximum Charger Capacity: 18 AH battery for MS-5UD- 3(E), and 26 AH battery for MS-10UD-7(E). [Two 18 Ah bat- teries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB-26 or BB-55.] Top Depth= 5.207° (13.23 cm) Door = 16.821° (42.73 cm) 10 Backbox = 16.65" (42.29 cm) Depth = 5,257"— Left Side Right Side Bottom Cabinet Measurements Page 2 of 4— DF-524160 • 07/26/2010 Minimum Battery Size: 7 AH. Initiating Device Circuits - TB4 (and TB 6 on MS-10UD-7 only): Alarm Zones 1 -5 on TB 4 (MS-5UD-3 and MS-i OUD-7). Alarm Zones 6- 10 on TB6 (MS-i OUD-7 only). Supervised and power-limited circuitry. Operation: All zones Style B (Class B). Normal Operating Voltage: Nominal 20 VDC. Alarm Current: 15 mA minimum. Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 ohms. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL- listed). Standby Current: 2 mA. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. Notification Appliance Circuits - TB5 (and TB 7 on MS- 10UD-7 only): Four NACs Operation: Style V (Class B) Special Application power Supervised and power-limited circuitry Normal Operating Voltage: Nominal 24 VDC Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A maximum per NAC; 7.0 A for MS-10UD-7(E), 3.0 A maxi- mum per NAC. End-of-Line Resistor: 4.7K ohm, 1/2 watt (Part #71252) Max. Wiring Voltage Drop: 2 VDC Refer to the Fire•Lite Device Compatibility Document for com- patible listed devices. Form C Relays - TBB: Relay I (factory default programmed as Alarm Relay) Relay 2 (factory default programmed as fail-safe Trouble Relay) Relay 3 (factory default programmed as Supervisory Relay) Special Application Resettable Power - TB9: Jumper selectable by JP31 for resettable or nonresettable power. Operating voltage: 24 VDC nominal. Maximum available current: 500 mA - appropriate for pow- ering four-wire smoke detectors. Power-limited circuit. Refer to the Fire•Life Device Compatibility Document for listed compatible devices. Remote Sync Output - T132: Remote power supply synchro- nization output, only required for the MS-5UD-3. 24 VDC nom- inal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- ited circuit. Product Line Information MS-51.113-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). 120 VAC operation. MS-5UD-3E: Same as MS-5UD-3 except for 240 VAC opera- tion. (MS0UbJ7: Ten-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame & post operating instruction sheet). MS-i OUD-7E: Same as above with 240 VAC FLPS-7. IPDACT, IPDACT-212UD Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static lR (See data sheet DF-60407 for more information.) IPBRKT: Mounting kit for IPDACT in common enclosure. IPSPLT: V Adaptor option to allow connection of both panel dialer outputs to one cable input to IPDACT (sold separately). OPTIONAL MODULES CAC-5X: Optional (Class A) Converter Module. Converts Style B (Class B) Initiating Device Circuits to Style D (Class A); and Style Y (Class B) Notification Appliance Circuits to Style Z (Class A). Connects to J2 on the MS-5UD-3 and MS-i OUD- 7(E) main circuit board and to J7 on the MS-10UD-7(E). NOTE: Two Class A Converter Modules are required for the ten- zone panel. 4XTMF: Transmitter module. Provides a supervised Output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5. COMPA TIBLE ANNUNCIA TORS ANN-80: Remote LCD Annunciator. Mimics the information displayed on the FACP's LCD. Red. (For white, order: ANN- 80-W.) ANN-LED: LED Annunciator with three LEDs for each zone: Alarm, Trouble, and Supervisory. Mounts in the DP-51050(B) dress panel. Red. (For white, order ANN-LED-W.) ANN-RLED: LED Annunciator with three alarm (red) indica- tors for up to 30 input zones or addressable points. (Red. For white, order ANN-LED-W.) (See DF-60241). ANN-RLY: Relay module. Mounts inside the cabinet. Provides ten Form C relays. ANN-S/PG: Serial/parallel printer gateway. Provides a connec- tion for a serial or parallel printer. ANN-I/O: Driver module. Provides connections to a user-sup- plied graphic annunciator. ACCESSORIES DP-51050: Optional dress panel. Restricts access to the sys- tem wiring while allowing access to the membrane switch panel. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55: Battery backbox, holds up to two 25 AH batteries. TR-CE: Optional trim-ring for semi-flush mounted cabinets. PRN-6F: UL listed printer. DF-52416:D • 07/26/2010 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Annunciators .8 Electrical Specifications MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, 1.OA MS-lOUD-i (FLPS-7 Power Supply): 120 VAC, 60 HZ, 3.90 A MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, 2.20 A. Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower-limited Cabinet Specifications Door: 19.26° (48.92 cm.) high x 16.82° (42.73 cm.) wide x 0.72° (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65' (42.29 cm.) wide x 5.25° (13.34 cm.) deep. Trim Ring (TR-CE): 22.00' (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: - 20.00" (50.80 cm.) high —22.5(57.15cm.) wide - 8.5" (21.59 cm.) deep. Weight: 27 lb (12.20 kg) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C132 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the basic MS-5UD-3 and MS-10UD-7 control panels. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: File S624 FM Approved (CSFM:.7165-0075:0214) MEA: MEA: 333-07-E NOTE: For ULC-listed models, see DF-60440. NFPA Standards The MS-5UD-3(E) and MS-10UD-7(E) complies with the fol- lowing NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Network) FireLite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I o 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. lGlNlN QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-524160 • 07/26/2010 Calculating the System Current Draw Power Supply Calculations / Calculation Column I - The primary supply current load that the control panel must support during a non-fire alarm condition, with AC power applied. / Calculation Column 2 -'he primary supply current load that the control panel must support diii fiiln condition, with AC power applied. / Calculation Column 3(The_sthndbyurrent drawn from the batteries in a non-fire alarm condition during a loss ofAC power. Table 7.3 contains three columns for calculating current draws. For maximum output current availability per circuit and per panel, refer to Section 1 2 'Specifications on page 13 For each column calculate the current and enter the total (in amperes) in the bottom row When finished, copy the totals from Calculation Column 2 and Calculation Column 3 to Table 7.4 on page 112. Calculation Column I Calculation ColumiI 2 Calculation Column' Device Type Primary, Non-Fire Alarm Current Secondary, Fire Alarm Current Secondary, Non-Fire Alarm Current (amps) (amps) (amps) Qty xicurrent Total Qty X [current drawl Total Qty X[current Total Main Circuit Board MS-5UD 1 X[O.110] I X[0.214]12 1 X[O.110] ,0f -"s MSt0JJDJ X[0.133?' (X[0282]1 2 (X[0.133]) CAC-5X [ X[0.001] [ X[0.001)' [ ] X[0.001] 4XTMF [ J X[0.005] [ ] X[0.0111= [ J X[0.005]= 1 max. I max. 1 max. ANN-SEC card [ ] X[0.003] [ J X[O.003]= [ ) X[O.003]= 1 max. 1 max. I max. ANN-80(C) [ ] X[0.037= [ (xio.oioj= I( X10.0151= ) ANN-I/O [ ] X[0.035]= [ ] X[0.200] I J X[0.035] ANN-RLY ] X[0.015]= ( X0.075] . [ J X[0.015] ANN-(R)LED3 E ] X[0.028]= I ] X[o.068]= I ] X[0.028] ANN-S/PG 1 1 X[0.045] [ I X0.045] [ ) X[0.045]= 2-wire Detector [ 1 X[ ]4= j5 X[0.040]= I ] X[ ]4= Heads 4-wire Detector [ ] X[ ] [11 X[0.0401 [ ] X[ ] Heads Power [ ] X[0.025] I X[0.025] 1 X[0.025]= Supervision Relays6 NAC#1 [ ] X( 1 [ I X[ 1= NAC#2 NAC#3 NAC#4 1 I ]= I Current Draw from TB9 (nonalarm) Sum each column7 for Primary Non-Alarm = Secondary Alarm = Secondary Non-Alarm = totals Table 7.3 System Current Draw Calculations If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. The current draw shown represents one zone (IDC) on the main circuit board in alarm. One zone consumes 0.040 amps. An ANN-LED is supplied standard with the MS-5UDC and MS-1 OIJDC. Refer to the Device Compatibility Document for standby current. Enter the number of lDCs used minus one. Must use compatible listed Power Supervision Relay. Total current draw listed above cannot exceed 3.25 amps for the MS-5UD-3(E), 3.28 for the MS-10UD-3(E), 7.25 for the MS-5UD- 7(CIE). and 7.28 for the MS-iOU D-7(CIE). MS-5VD & MS-lOUD series Manual- P/N 52626:C7 6/12/2018 . 111 :'..., CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7165-0075:0214) CATEGORY: 7165 - FIRE ALARM)CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITEALAFiS)INC. One Fire-Lite Place, Northford, CT, 06472 Contact: Brant,Lisa (203) 484-6105 (203) 484-7309 Email: Iisa.brant@honeywell.com DESIGN: ______ Model MS-5UD-3, MS-5UD-3E, MS-5UD-7, MS-5UD-7C, MS-5UD-7E,{4S-10Up3, MS-i OUD-3E, MS- 1OUD-7, MS-i OUD-7C AND MS10-UD-7E Fire alarm control units. The MS-5UD series has five input zones and the MS-lOUD series has ten input zones. Both product lines have four notification appliance circuits, and three relay contact outputs for alarm, trouble and supervisory and include an integral two- line digital alarm communicator transmitter (DAd). The -3 suffix represents the 3 amp total power variant utilizing the FLPS-3 and the -7 suffix represents the 7 amp total power variant utilizing the FLPS- 7. The "E" suffix represents 240 V ac 50 Hz rated products. The "C" suffix represents products that have the separately listed ANN-LED annunciator module already installed. * These Models are intended for the following applications: Local, Auxiliary, Remote station, Central Station, and Proprietary. Refer to listee's data sheet for detailed product description and operational considerations. System components: FLPS-3:; Power Supply Module FLPS-7; Power Supply Module 4XTMF; Transmitter Module CAC-5X; Converter Module ANN-LED; Annunciator Module ANN-RLY; Relay Module *ANN..SEC; Secondary ANN-BUS Module 1PDACT; IP Digital Fire Alarm Communicatior RATING: *120 VAC or 230 VAC primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. This control unit meets the requirements of UL Standard 864, 9th edition. Page 1 of 2 r. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE *Rev 04-23-15 gt This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/30/2024 (Listing Expires: 06/30/2025) Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 System Sensor j3" series smoke detectors represer significant advancement in conventional detect, The i3 family is founded on three principles: instal, Photoelectric) Smoke Detectors) SYSTEM $ SENSOR ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings @ LISTED <~> APPROVED 0 MEA MSFM approved approved AM 5911 3011446 7272-1653:152 290-01-E 2093 3180932 Installation eae.The i3 line redefines installation ease with its plug-in cesign.This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample rcom for reatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop 'N Lock' action. Intelligence. P cetectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algori:hms are standard with the P line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicatec maintenance signal when connected to the 2W-MOD2 loop test'mainteriance module or a panel equipped with the I protocol. The SEN-RDR, a wireless device, displays the sensitivityofi3 detectors in terms of percent-per-foot obscuration. Instant Inspection. The P series provides wide-angle red and green LED indicators for instant inspection of the detector's conditior: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on 2-wire P detectors, This feature verifies the initiating loop wiring by providir.g LED status indication at each detector. (j) Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4W1-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5 V Maximum: 35V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 q) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4W1-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2C) fixed Freeze Trouble 2W1-8 and 41/it-8 only: 41°F (5°C) Sensitivity 2.50/o/ft nominal InputTerminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information ITModel Thermal Viflhir. Alarm Current Aax limited by control panel) 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20mA@ 12V,23 mA@24V 4WT-B Yes 4-wire 20mA@ 12V,23 mA@24V Accessories 2W-MOD2 2-wire loop test/maintenance module RI Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter 3825 Ohio Avenue. St. Charles, IL 60174 2OO9SY3tCflSCSOt SYSTEM Product spec Icat onu subject to change without notice. Visit systernnensot.cornr for ISEIISOR Phone: 800-SENSOR2 Fax: 630-377-6495 current productrnforrnanon, ncIodtn the htentvernon of this data sheel A050318-7-6/09.92169 System Sensor Detectors - continued: Model Number Model Bass S. OU MS-2 MS-4 MRP-2001 MRP-2002 MM302 $1000 S2000 2W-13 N/A N/A 16 20 N/A N/A 2WT B N/A N/A 16 20 N/A N/A 1100/1) N/A 20 20 24 N/A 25 1151 B401/BI1OLP/BII6LP 16/16/1 16/16/1 20/20/1 N/A 20/20/1 1400 N/A 20 20 24 20 25 1451 B401B/B406B/ BIIOLP/BII6LP 16/1 16/1 16/1 16/1 20/1 20/1 20/1 20/1 20/1 20/1 1451DH DH-400 16 16 -20 20 20 1800 N/A N/A N/A 24 N/A 1851B B1O1B N/A N/A 20 N/A 1851B 51078 N/A N/A I N/A 1851DH DH1851DC 16 16 20 20 20 2100/D/$ N/A 16 16 20 N/A 20 21001/D/S N/A 16 16 20 N/A 20 2151 8401/B11OLP/B116LP 16/16/1 16/16/1 20/2011 NIA 20/20/1 2300T N/A 16 16 20 20 20 2400 N/A 16 16 20 20 20 2400A11 N/A 1 1 1 1 1 2400AT N/A 1 1 1 1 1 24001H N/A 16 16 20 20 20 2451 84018/840681 B110LP/BI16LP 16/1 16/1 16/1 16/1 20/1 20/1 20/1 20/1 20/1 20/1 2451 DH-400 16 16 20 20 20 2451TH B401B/8406B/ B1IOLP/B1I6LP 16/1 16/1 16/1 16/1 20/1 20/1 20/1 : 20/1 20/1 20/1 2800 N/A N/A N/A 20 N/A 28001H N/A N/A N/A 20 N/A 2851B BIO1B N/A N/A 20 N/A 2851B BI07B N/A N/A I N/A 2851BTH BIOIB N/A N/A 20 N/A 2851 BTH B107B N/A N/A I N/A 2851DH DH2851DC 16 16 20 20 20 DHIOOP N/A 20 16 24 N/A 25 DH100LP N/A 16 16 20 N/A 20 2WrA-B N/A N/A I N/A N/A N/A 2WrAR-B N/A N/A I N/A N/A N/A Fire-Lite Device Compatibility Document— P/N 15384:BN 8/27/2020 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 76530152j CATEGORY: 727SivfOi) DETECTOR-SYSTEM TYPE-PHOTOELECTRIC - LISTEE: System Sensor, UiiincorporatedDiv of Honeywell Int'l Inc. 3825 Ohio Ave, St. Charles, IL, 60174 Contact: Brant, Lisa (203) 484-6105 (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: ____ Models 2W-B) 2WT-B, 4W-B, and 4W7-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and models 4W-B and 4WT-B are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. *The above models comply with UL 268, Seventh Edition. RATING: 8.5-35VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0- 1000 ft/mm. NOTES: Formerly 7272-1209:210 *Revision 09-21- 20 V\NW 2 Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to 1istees data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/03/2024 ng.çpires: 06 0/2025) Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 DF-52004:A1 • F-050 (BG-1 2 Series) Manual Fire Alarm Pull Stations Conventional Initiating Devices rci 1 The Fire-Lite BG-12 Series is a cost-effective, feature-packed series of non-coded manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series features a variety of mod- els including single- and dual-action versions. The BG-12 Series provides Fire-Lite Alarm Control Panels (FACPs), as well as other manufacturers' controls, with a man- ual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting options make the BG-12 Series simple to install, maintain, and operate. Features Aesthetically pleasing, highly visible design and color. Attractive contoured shape and light textured finish. Meets ADA 5 lb. maximum pull-force. Meets UL 38, Standard for Manually Actuated Signaling Boxes. Easily operated(single- or dual-action), yet designed to pre- vent false alarms when bumped, shaken, or jarred. PUSH IN/PULL DOWN handle latches in the down position to clearly indicate the station has been operated. The word "ACTIVATED" appears on top of the handle in bright yellow, further indicating operation of the station. Operation handle features white arrows showing basic opera- tion direction for non-English-speaking persons. Braille text included on finger-hold area of operation handle and across top of handle. Multiple hex- and key-lock models available. U.S. patented hex-lock needs only a quarter-turn to lock! unlock. Station can be opened for inspection and maintenance with- out initiating an alarm. Product ID label viewable by simply opening the cover; label is made of a durable long-life material. The words "NORMAL" and "ACTIVATED" are molded into the plastic adjacent to the alarm switch (located inside). Four-position terminal strip molded into backplate. Terminal strip includes Phillips combination-head captive 8/32 screws for easy connection to Initiating Device Circuit (lDC). Terminal screws backed-out at factory and shipped ready to accept field wiring (up to 12 AWGI3.1 mm2). Terminal numbers are molded into the backplate, eliminating the need for labels. Switch contacts are normally open. Can be surface-mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single-gang, double-gang, or 4' (10.16 cm) square electrical box. Backplate is large enough to overlap a single-gang backbox cutout by 1/2" (1.27 cm). Optional trim ring (BG12TR). Spanish versions (FUEGO) available (BG-12LSP, BG-12LPSP). Designed to replace the Fire-Lite legacy BG-10 Series. Models packaged in attractive, clear plastic (PVC), clam- shell-style, Point-of-Purchase packages. Packaging includes a cutaway dust/paint cover in shape of pull station. Construction Cover, backplate and operation handle are all molded of durable polycarbDnate material. Cover features white lettering and trim. Red color matches System Sensor's popular SpectrAlert® Advance horn/strobe series. Operation The BG-12 manual pull stations provide a textured finger-hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the sta- tion, provided for noi-English-speaking people. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word "ACTIVATED" appears at the top in bright yellow, with a portion of the handla protruding at the bottom as a visible flag. Resetting the station is simple: insert the key, twist one quarter- turn, then open the station's front cover, causing the spring- loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch. DF-52004:A1 • 04/22/08 - Page 1 of 2 Specifications PHYSICAL SPECIFICATIONS: pull station SB-I/O SB-10 Height 5.5 inches 5.601 inches 5.5 inches (13.97 cm) (14.23 cm) (13.97 cm) Width 4.121 inches 4.222 inches 4.121 inches (10.47 cm) (10.72 cm) (10.47 cm) Depth 1.39 inches 1.439 inches 1.375 inches (3.53 cm) (3.66 cm) (3.49 cm) 520046mibl ELECTRICAL SPECIFICATIONS: Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or VDC. ENGINEERING/ARCHITECTURAL SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- or hex-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Under- writers Laboratories listed. NOTE: *The words "FIREIFUEGO" on the BG- 12LSP shall appear on the front of the station in white letters, approximately 3/4" (1.905 cm) high. Agency Listings and Approvals The listings and approvals below apply to the BG-12 Series pull stations. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. C(UL)US: S711 FM Approved Mi50o7T18 MEA: 67-02-E Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Product Line Information BG-12S: Single-action pull station with pigtail connections, hex lock. BG-12SL: Same as BG-12 with key lock. tB13-12: Dual-action pull station with, SPST N/O switch,screw (terminal connections,jjqcJ BG-12L: Same as BG-12 with key lock. BG-12LSP: Same as BG-12L with English/Spanish (FIRE] FUEGO) labeling. BG-12LOB: Same as BG-12L with "outdoor use" listing. Includes outdoor listed backbox, and sealing gasket. BG-12L0: Same as BG-12L with "outdoor use" listing. Does not include backbox. BG-12LA: Same as BG-12L with auxiliary contacts. BG-12LPS: Dual-action pull station with pre-signal option. BG-12LPSP: Same as BG-12LPS with English/Spanish (FIRE] FUEGO) labeling. SB-10: Surface-mount backbox, metal. SB-I/O: Surface-mount backbox, plastic. (Included with BG- 12LOB.) BG12TR: Optional trim ring for semi-flush mounting. 17003: Keys, set of two. (Included with key-lock pull stations.) 17007: Hex lock, 9/64". (Included with hex-lock pull stations.) NOTE: For addressable BG-I2LX models, see data sheet DF- 520 13. Fire-Lite® Alarms, SpectrAlert® Advance, and System Sensor® are registered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. ffilliffOUNI & &WilIFAC11RINC All specifications are subject to change without notice. DUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52004:A1 • 04/22/08 ....,. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 71500075014) PARENT LISTING No.: 7150-0028:0199 CATEGORY: 7150FIRE)ALARM PULL BOXES LISTEE:'FIRE-LITE ALARMSJINC. One Fire-Lite Place, Northford, CT, 06472 Contact: Brant, Lisa (203) 484-6105 (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Models BC-I 2BG-12S, BC-I 2NC, BG-I 2W, BC-i 2LW, BG-I 2WP, BG-I 2LWP, BG-1 2L BG-12LX, BG-I2LA, BG-12PS, BG-12LSP, BG-I2SP, BG-I2LR, BG-12LRA, BG- 12LA0, BG-I2LAOB, BG-12-LO, BG-12LOB, BG-I2LPS, BG-I2LPSP, BG-125L, UT- PSI and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-I2WP, BG-12W, BG-I2LW and BC-I 2LWP are intended for outdoor use when installed with Model WP-I0 back box. Models BG-LAOB and BG-I2LOB are intended for outdoor use when installed with Model WBB or WP-1 0 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. NOTES: *Updated 08-17- 09 fm Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test resultsand/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/08/2024 (EJitingçpires: 0613012025) Authorized By: David Castillo Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 4 COMMERCIAL FIRE Part of the full line of Telguard universal fire communicators, the TG-7FS can augment or replace legacy Telco lines with reliable cellular signal reporting. AHJs know that the TG-7FS meets all UL and ULC standards, and works in virtually every installation. PRODUCT FEATURES I- Powers directly from a 12 or 24VDC alarm panel - no electrician needed for an outlet. Or, for AC, use included plug-in adapter. I- Operates on LTE-M networks, for 5G longevity, lower power consumption, and better in-building penetration. I- Interfaces with fire panels using a single DACT connection for universal compatibility. No DACT is no problem - just add a TG-PEM accessory to the TG-7FS. I- American made, and backed by award-winning, U.S.-based tech support. This is the communicator dealers have loved for over a decade, updated with a more modern 5G LTE-M cellular radio, more efficient use of power, and more options. You're in control when setting up and installing the TG-7FS. Apply desired settings when you're in the office or on the road using the Telguard online dealer portal. Signals can be reported to your central station of choice. For the most current product specifications and LJL Listings visit telguard.com/tg-7fs. In Canada, cellular data may be carried by Rogers, Bell, Talus or SaskTel. CHOOSE THE COMMUNICATOR THAT BEST FITS THE NEEDS OF YOUR UPGRADE, TAKEOVER, OR NEW INSTALL PROJECT. FIRE PRODUCTS COMMUNICATION PATHWAYS INPUT POWER OPTIONS HARDWARE OPJ TG-PEM MODEL CELLULAR INTERNET TELCO PANEL DC (12/24V) PLUG-IN AC UPGRADE BOARD CTG- F ::~J 7F truui - - TG-E TG 7FP 1 1 T E 800.229.2326 1 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 • USA I telguard.com @2021 Telguard I Telguard and the Telguard Logo are registered trademarks of Telular Corporation. I Telular is a business unit of AMETEK, Inc. All Rights Reserved. AMETEIC CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I 1 OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION IJ BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7300-1402:0504) CATEGORY: .730 ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES - LISTEE: TELULAR CORP. 3325 Cumberland Blvd, NE, Suite 300, Atlanta, GA, 30339 Contact: Stewart, Sean (800) 229-2326 (678) 945-1651 Email: sean.stewart@ametek.com DESIGN: ______ ITGS]and TG-7UB Digital Cellular Radio Alarm Transmission Devices for fire alarm systems. Models are suffixed with -A for AT&T networks and -for Verizon networks. Devices facilitate the use of the cellular network for the delivery of signals for commercial alarm panels. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 12/24VDC regulated (from panel) I2VAC (from plug-in adapter) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as digital cellular alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed fire alarm control panel in accordance with the installation instructions provided by the manufacturer. NOTES: 02-16-22 DAL This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/06/2024 (Ltiiing Expires: 06/30/2025) Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL Ji4l FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2