Loading...
HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; FPC2023-0050(bty of Carlsbad Print Date: 06/17/2024 Job Address: 5781 VAN ALLEN WAY, CARLSBAD, CA 92008-7321 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2121304400 Track #: Valuation: $316,545.52 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2023-0050 Status: Closed - Finaled Applied: 03/14/2023 Issued: 04/14/2023 Finaled Close Out: 06/27/2023 Final Inspection: INSPECTOR: Salcedo, Felix Project Title: Description: THERMO FISHER -INSTALL NEW ADDRESSABLE FIRE SUPPRESSION CONTROL PANEL FOR RELEASING SERVICE FOR FREEZER (AM&M FPC2021-0109 ADDENDUM IN LINKED RECORDS) Applicant: FPContractor: ADT COMMERCIAL ADT COMMERCIAL LLC GREGORY COX P0 BOX 310702 920 SAN DREASEN DR, # STE 102 BOCA RATON, FL 33431-0702 ESCONDIDO, CA 92029-1936 (561) 989-7919 (619) 719-2633 FEE AMOUNT FIRE Hourly Services (each additional hour) $160.00 FIRE Hourly Services (first hour) $188.00 FIRE Sprinkler Monitoring $453.00 Total Fees: $801.00 Total Payments To Date: $801.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov ADT- Commercial Powered by Experience. Driven by Excellenc&" Fire Suppression Panel Product Submittal FOR THERMO FISHER 5781 Van Allen Way Carlsbad, Ca 92008 SUBMITTED BY: ADT COMMERCIAL 10107 Carroll Canyon Road San Diego, CA 92111 (760) 233-9787 1501 YAMATO ROAD, BOCA RATON, FL 33431 adt.com/commercial 2020ADr CornmcciILLC.Mrights r&vd. (E)POTTER C11c -1ob The Symbol of Protection Fire Alarm Releasing Control Panel Features 100 addresses available on this analog addressable system Additional system capacity achieved via multi-point SLC modules 99 software zones NFPA 72 Compliant Smoke Sensitivity Test Built-In System Operates as Class A or Class B for SLC, P-Link and NACs 5 Amp Power Supply, Expandable to 310 amps 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 2 Input/Output (I/O) Circuits for system flexibility rated at I Amp each, ideal for manual release and abort Strobe Synchronization and System Wide Sync for Gentex®, AMSECO®, Cooper Wheelock® and System Sensor® strobes Dedicated Alarm, Supervisory and Trouble Relays 4,000 Event History Buffer Optional two line DACT with UD-2000 that can report General, Zone or Point Information Built in IP Communicator Ethernet Port for Programming and Network Connectivity E-Mail System Status, Reports and Event Information NYC Fire Dept. Product includes 5 year warranty Certificate of Approval 6256 LISTED APPROVED 7165-0328:0509 S735 Description The ARC-100 is an analog/addressable releasing fire alarm system with a total system capacity of 100 addresses. Additional capacity on the system is achieved using multi-point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The ARC-100 has a 5Amp power supply with two Notification Appliance Circuits (NACs) and two Input/Output (110) circuits. The NACs are rated at 3 Amps each and the I1Os are rated at lAmp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Gentex, AMSECO, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The J1Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously. The ARC-100 is listed for releasing of fire suppression systems. The software allows cross zones, counting zones, and timers for suppression. The system is capable of multiple release outputs across multiple hazards. In addition, the PSN-1000 may be used to extend releasing capability. The NACs may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the ARC-100 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN- 1000E has space to allow the installation of up to six loop expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections. Technical Specifications Dimensions 16"W x I711 x 3 "D AC Mains 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current-130 mA Alarm Current-200 mA 5 Amps power for NACs, I/O, and P-Link Battery 3 Amps per NAC, regulated 1 Amp per I/O circuit, regulated Battery Charger range 8-55 Ah Battery Charger voltage 27.3 VDC P-Link maximum current of! Amp Temperature and 32° to 120° (0°C to 49°C) with a maximum Humidity Range humidity of 93% non-condensing. NFPA, 12, 12A, 13, 15, 16, 17, 17A, 70, 72, 92, 720 ,750, and 2001 ANSI/UL 864 - Local (L), Remote Station (RS), Central Station (CS), Propriety (PPU), Auxiliary (AUX). Type of Service: Standards Automatic (A), Manual (M), Water flow (WF), Sprinkler Supervisory (SS), Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded (NC), Reverse Polarity (Rev P01), Other Technologies (OT) IBC (International Building Code) Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830136- REV F • 2/22 PAGE 1 OF 5 (E)POTTER ARC-1 00 The Symbol of Protection Fire Alarm Releasing Control Panel SLC Loop Accessories The control panel may be connected with up to 100 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description (PAD200-P Analog Photoelectric Smoke Detector is a smoke detector with a listed obscuration of 1.0 to 3.5%/foot. UL 268 7th Edition. PAD200-PHD Combination Analog Photoelectric Smoke/Heat Detector - a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature range of 135° to 185° F heat detector. Smoke detection compliant with UL 268 7th Edition. PAD200-PCD Combination Photoelectric Smoke/Carbon Monoxide Detector. Smoke detection compliant with UL 268 7th Edition. Carbon Monoxide detection compliant with UL 2075. PAD200-PCHD Combination Photoelectric Smoke/Heat/Carbon Monoxide Detector. Smoke detection compliant with UL 268 7th Edition. Heat detection with a fixed temperature range of 135° to 185° F and is UL 268 and UL 521 7th Edition compliant. Carbon Monoxide detection compliant with UL 2075. PAD100-HD Analog Fixed Temperature (135° - 185°F) or Rate-of-Rise Heat Detector (software selectable). PAD200-DUCTR Addressable Duct Smoke Detector with Form C Relay rate at lOAmps @ 250/120VAC or 8 Amps at 30VDC. PAD200-DUCT Addressable Duct Smoke Detector. PAD 100-6B 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD100-413 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD 100-TB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD100-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. PAD 100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. PAD100-CD Addressable CO gas detector. PAD 100-DD Addressable photoelectric smoke detector for use in DUCT/DUCTR enclosure. PAD 100-LFSB Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz). PAD 100-SPKB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830136- REV F • 2/22 PAGE 2 OF 5 (E)POTTER ARC-1 00 The Symbol of Protection Fire Alarm Releasing Control Panel Modules Device Description PAD 10O-M1M'1 Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD 100-PSSA Single Action Addressable Pull Station. PAD 100-PSDA Dual Action Addressable Pull Station. PAD100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PAD 100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD 100TRT1 Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125 VAC. Also provides two contact inputs. PAD 100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PADI 00-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD 100-TM Isolater Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD 100-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. PAD 100-LED Module provides a single addressable LED that is controlled by the control panel. PAD 100-SM Speaker Module provides switching for two audio channels. PAD 100-LEDK Addressable LED and key switch that mounts in a single gang box. PAD 100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. For use with the PAD 100-DUCTR only. PAD 100-OROI One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125 VAC. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830136- REV F • 2/22 PAGE 3 OF (E)POTTER The Symbol of Protection SLC Features The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The system does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T-Taps", with a max wiring distance of 10,000 Ft. Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity.. User Interface The fire alarm control panel has a 2 x 16 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: AC Power - Green Alarm - Red Earth Fault - Amber Supervisory -Amber Silenced - Amber Trouble - Amber Pre-Release - Amber Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-Link The AFC-50 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 32 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: SLCE-127 -Nohmi addressable loop expansion module for retrofit applications. RA-6075R - 2 x 16 LCD annunciator with a key pad in a locked metal enclosure. ARC-1 00 Fire Alarm Releasing Control Panel RA-6500R(F) —4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) - 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) - 10 amp, remote intelligent power supply with 6 NACs, 2 Inputs and a P-Link repeater. This panel is listed in conjunction with the AFC-50 as releasing circuits. CA-6075 - Class A convertor that converts the SLC, NACs and P-Link connection UD-2000 - UL listed, Dual line telephone alarm communicator DRV-50 - LED driver expander, used to connect up to 50 LEDs in a graphic display FCB-1000 - Fire communication bridge, provides remote mounting of the Ethernet connection FIB-1000 - Fiber interface module, used to extend P-Link to multi- mode fiber (2 required) RLY-5 - Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 - Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi-Connect allows up to sixty-three AFC series panels to share a single reporting technology. IDC-6 - Initiating device circuit provides 6 programmable inputs AE-2 - Two card expansion cabinet AE-8 - Eight card expansion cabinet AE-14 - Fourteen card expansion cabinet Ethernet/I.P. Connection The AFC-50 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UI. listed Sur-Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830136- REV F • 2/22 PAGE 4 OF 5 (E)POTTER The Symbol of Protection ARC-1 00 Fire Alarm Releasing Control Panel Dimensions 0 of TOP DEPTH=3.75' DOOR= 16.07" BACKBOX= 15.77 DEPTH =3.84 co oil LEFT SIDE BOTTOM L RIGHT SIDE DM #593-I Ordering Information Model Description Stock No. ARC-100 Fire Alarm Releasing Control Panel 3992755 Replacement Board ARC-100 3992759 Compatible Releasing Devices Note: For releasing applications please order the Potter EOLD (3005012) for circuits connected to a releasing solenoid or actuator. Brand Description Skinner 73218BN4UNLVN0C112CZ 732 12BN4TNLVN0C322C2 Victaulic 753-E Series Mini Max MiX123 & MX200 wl 8876677 & 889323 Viking 11591, 11601, 11602, 13843,& 13844 TLX PA0036 Stat-X 30E, 60E, 100E, 250E, 500E, l000E, 1500E, & 2500E Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830136 - REV F • 2/22 PAGE 5 OF 5 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ..... OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0509 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Michael Mclsaac (314) 628-2218 Fax (314) 595-6999 Email: michaelm@pottersignal.com DESIGN: Models AFC-50, AFC-100 and AFC-1000 fire alarm control units. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, remote station (PPU), proprietary (PPU) and central station (PPU) services. *ModeIARC10fire alarm control unit. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. System components: PAD 100-DIM Dual Input Module PADIOO-LED Addressable LED Module PAD 100-OROI One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SIM Single Input Module PAD 100 TRTI Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 100-IM lolator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module AD 100-MIM Micro Input Module'. PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander MC-1000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure Refer to listee's Installation Instruction Manual for details. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. *Rev 12-04-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Listing No. 7165-0328:0509 Page 2 of 2 MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. *Rev 12-04-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division (E)POTTER The Symbol of Protection Features UL 268 7th Edition Low profile, less than 2 inches with the base Wide selectable sensitivity range of 1.0 to 3.7%/foot Sensor communicates sensitivity to control panel UL listed smoke calibration and sensitivity Optional locking tab to prevent unwanted removal Simple DIP switch address setting, no programming tool required LED alarm indicator Product includes a 5 year warranty UUKL Listed for Smoke Control Description The Photoelectric Smoke Sensor is a listed Analog Addressable smoke sensor compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD200-PD is a low profile smoke sensor with a wide sensitivity range. The sensor and base (not included) are made of a durable plastic in an off-white color to blend in with the ceiling. The PAD200-PD has a sensitivity range of 1.0 to 3.7 % per foot and is UL. The PAD200-PD features drift compensation and has built in dirty detector warning as well as. The PAD200-PD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The sensor is compatible with any of the PAD series sensor bases and simply twists on. The PAD200-PD is addressed using DIP switches in the rear of the sensor and can be easily programmed in the field without special tools. Setting the Address Each addressable device on the SLC loop must have a unique address from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: 'PAD2OO-PD Photoelectric Smoke Sensor' LISTED Technical Specifications Operating Voltage 24 VDC Detector Current Draw 300 jiA Alarm indicator 1 LED Alarm set-point range 1.0 to 3.7 %/ft 3.6-12 %/m Installation temperature 32to120°F/ 0to49°C range Operating relative 0% to 93% (Non-condensing) humidity range Start-up time Max. 1 sec. Maximum number of 127 addresses per loop Maximum number of lighted indicators in 30 alarm per loop. Color Eggshell White Weight (without base) lOig (3.560z) Dimensions (without Height: 1.35 in (34mm) base) Diameter: 3.93 in (100 mm) Power to the device is removed Field wiring is correctly installed. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830172- REV A • 5/21 PAGE 1 OF 2 (E)POTTER PAD200-PD The Symbol of Protection Photoelectric Smoke Sensor Air Velocity Ratings The PAD200-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD200-PD will operate even though the LED may not illuminate. Operation The PAD200-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status. The polling LED can be turned off if desired for less conspicuous operation. The PAD20 0-PD with the PAD 100-4DB or PAD 100-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PAD200-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the sensor is installed over time, the sensor compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty sensor. The sensor will then have to be cleaned or replaced. The PAD200-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. NOTE: As required by NFPA, do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. If the sensors have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service. Spacing The PAD200-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4" Standard Base 3992731 IPAD100-61)13) (6" Standard Base) 3992732 PAD 100-lB 6" base with an isolator module included. 3992730 PAD 100-RB 6" base with one Form-C relay contact. 2A @ 30VDC, 0.5A @ 125 VAC 3992728 PAD 100-SB 6" base with sounder module included. Sound pattern is provided from external source. 3992729 PAD1 00-SPKB 6" base with speaker included 3992762 Ordering Information Model Description I Stock No. PAD200-PD Photoelectric Smoke Sensor 3992770 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830172- REV A • 5/21 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0328:0504 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Michael Mclsaac (314) 628-2218 Fax (314) 595-6999 Email: michaelm@pottersignal.com DESIGN: ModelsPAD100-PD PAD100-DD and PAD100-PHD photoelectric smoke detector heads. Model PAD100-PHD has an intergral heat detector. Refer to Listee's data sheet for detailed product description and operational considerations. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Models PAD100-PD and PAD100-PHD are listed as photoelectric smoke detector heads for use with listee's detector base Models PAD100-4DB, PAD100-6DB, PAD100-RB, PAD100-SB (CSFM#7300-0328:502) and Model PAD100-IB (CSFM#7300-0328:501). Model PAD100-DD is listed as a photoelectric smoke detector head for use with Model PAD100-DUCT(CSFM#3248-0328:0505). Refer to listee's Installation Instruction Manual for details. 06-21-2017 dcc es This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division (E)POTTER The Symbol of Protection I I (\PAD1OO4DB/6DB) \ - 4 /6"Addressable Detector Base Features Terminals Marked with Polarity to assist with installation Duplicate terminals for in and out SLC wiring Terminals accept 22 to 12 AWG wire sizes Installs on single gang, double gang, octagon or 4" square box Locking tab prevents unauthorized detector removal Product includes 5 year warranty <~> APPROVED LISTED Application The Potter PAD100-6DB and PAD100-4DB detector bases are used to install Potter's addressable smoke and heat detectors. The PAD100- 6DB will mount on a single gang, double gang, octagon or 4" square electrical box. Description The PAD100-6DB and PADIOO-4DB are low-profile, surface mount bases used with Potter's addressable detectors. The base uses screw- clamp terminals that accept wire ranging from 22 to 14 AWG. When installed on recessed electrical boxes the PAD 100-6DB is wide enough to completely cover the back box and the immediate surrounding area. The base is equipped with a locking tab to deter unauthorized removal of the attached detector. Technical Specifications Mounting Options Single gang, double gang, octagon, and 4" square box Terminals Screw-Clamp Type Wire Guage 22 to 12 AWG Diameter: 6.3 in (166 mm) Dimensions Height 0.72 in (18 mm) Shipping Weight 87g (3.07 ox) Material Durable Plastic Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com PRINTED IN USA 8830107- REV C • 12/18 PAGE 10F2 (E)POTTER The Symbol of Protection Locking Feature The PAD100-6DB and PADI004DB include a locking feature that prevents removal of the detector without using a tool. To eliminate this feature, break off the locking tab (refer to Figure 1), and then install the detector. Fig. I To remove the detector from the base when the locking feature has been enabled, insert a small screw driver into the slot on the base to push the plastic tab while simultaneously turning the detector head counter-clockwise. Fig. 2 PADI 00-4DB/6DB 4 '76" Addressable Detector Base Wiring Diagram Fig. 3 To FA( Loop (l Ordering Information Model Description Stock No. PAD100-6DB 6" Sensor Base 3992732 PAD100-4DB 4" Sensor Base 3992731 Insert small screwdr into slot to remove detector from base. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com PRINTED INUSA 8830107- REV C . 12/18 PAGE 2OF2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 4 LISTING SERVICE LISTING No. 7300-0328:0502 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Michael Mclsaac (314) 628-2218 Fax (314) 595-6999 Email: michaelm@pottersignal.com DESIGN: Models PAD 100-4DB,6i00-ë5) PAD 100-RB and PAD 100-SB detector bases. Refer to Listee's data sheet for detailed product description and operational considerations. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a addressable isolator base for use with separately listed compatible fire alarm control units and listee's separately listed Models PAD-100-PD and PAD-100-PHD (CSFM#7272-0328:0504), PAD-100-HD (CSFM#7270-0328:0503) and PAD-100-CD (CSFM#5278-0328:0506) detector heads. Refer to listee's Installation Instruction Manual for details. 06-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division (E)POTTER The Symbol of Protection Features One Class B contact monitoring input Small size allows mounting in most electrical boxes SLC Class A, Class X & Class B 6" Pigtail wiring connections Product includes a 5 year warranty UUKL Listed for Smoke Control Description The PAD100-MIIM is used to monitor the status of an initiating device(s) that contain a normally open set of dry contacts. The module is enclosed in a plastic case to protect against inadvertent shorts and ground faults. The case can be mounted using a single screw. The PAD 100-MJM has a status indicator LED to indicate communication and alarm condition. In normal condition, the LED flashes when the device is being polled by the control panel. When the input is activated, the LED will flash at a fast rate. Application The micro input module (PAD 100-MuM) is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. Generally the PAD100-MIM is used to monitor pull stations and other devices where the module is installed in an electrical box or enclosure behind the device being monitored. (PAD I 00-MIM Micro Input Module 1 124iZ4 M8 * - a C6 PAD 100-MIM (SLC Module)' II H <S> APPROVED Technical Specifications Operating Voltage 24.0V Max SLC Standby 200 pA Current Max SLC Alarm 200pA Current [DC Input Circuit Class B Wiring Max Wiring Resistance 100 92 of IDC Max Wiring IPF Capacitance of IDC EOL Resistor 5.lK0 Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module Per 127 units Loop Dimensions 1.75" (44.5mm)L x 1.36" (34.5mm)Wx .43" (llmm)D Mounting Options 2-1/2" (64mm) deep single-gang box Shipping Weight 0.3 lbs Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830079-REVD • 12/18 PAGE 1 OF 2 (E)POTTER PAD1 00-MIM The Symbol of Protection Micro Input Module Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the front of the PAD100-MIM. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. Wiring Diagram Fig 1 FROM FACP OR PREVIOUS ---/ DEVICE AND TO NEXT DEVICE TO NORMALLY OPEN MONITORED DEVICE 5.1K OHM REQUIRED Part #3005013 Ordering Information Model Description I Stock No. PAD 100-MIM Micro Input Module 3992700 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 . www.pottersignal.com 8830079- REV D • 12/18 PAGE 2 OF 2 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION .-... OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 1 LISTING SERVICE LISTING No. 7300-0328:0514 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Michael Mclsaac (314) 628-2218 Fax (314) 595-6999 Email: michaelmpottersignaI.com DESIGN: Model PAD100-DIM Dual Input Module Model PAD100-LED Addressable LED Module Model PAD100-OROI One Relay-One Input Module Model PAD 100-RM Relay Module Model PAD100-SIM Single Input Module Model PAD100-TRTI Two Relay-Two Input Module Model PAD100-ZM Zone Module Model PAD100-IM Isolator Module Model PAD100-NAC Notification Appliance Circuit Module Model PAD100-SM Speaker Module IModel PAD100-10IM Micro Input Module) Model PAD 1---LEDK Key Switch Module Model PAD100-DRTS Duct Remote Test Switch Model SLCE127 Point SLC Expander Model MC-1000 Multi Connect Model PAD100-DUCTR Model AE-2 Enclosure Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control unit accessories for use with listee's separately listed fire alarm control panels. Refer to listee's Installation Instruction Manual for details. 09-11-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division -t