Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5781 VAN ALLEN WAY; ; FPC2022-0163
PERMIT REPORT Cailsbad ((,Cityof Print Date: 06/17/2024 Permit No: FPC2022-0163 Job Address: 5781 VAN ALLEN WAY, CARLSBAD, CA 92008-7321 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2121304400 Track #: Applied: 09/01/2022 Valuation: $316,545.52 Lot #: Issued: Occupancy Group: Project #: Finaled Close Out: 06/26/2023 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix Plan Check#: Project Title: Description: THERMO FISHER - INSTALLATION OF ASPIRATING SMOKE SAMPLING SYSTEM IN FREEZER (LINEAR HEAT DETECTION SYSTEM) Applicant: FPContractor: ADTCOMMERCIAL ADT COMMERCIAL LLC GREGORY COX P0 BOX 310702 920 S ANDREASEN DR, # STE 102 BOCA RATON, FL 33431-0702 ESCONDIDO, CA 92029-1936 (561) 989-7919 (619) 719-2633 FEE AMOUNT FIRE Hourly Services (each additional hour) $160.00 FIRE Hourly Services (first hour) $188.00 FIRE TI Fire Alarm System $735.00 Total Fees: $1,083.00 Total Payments To Date: $1,083.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov I* ADT-, Commercial Powered by Experience. Driven by ExceIIence Linear Heat Detection System Product Submittal FOR Thermo Fisher Scientific 5781 Van Allen Way Carlsbad, Ca 92008 SUBMITTED BY: ADT COMMERCIAL 10107 Carroll Canyon Road San Diego, CA 92111 (760) 233-9787 1501 YAMATO ROAD, BOCA RATON, FL 33431 adt.com/commercial C2020 AD Commercial LLC. All rights rsrved. -'- p Ir PROTt&OWIRE® DATA SHEET , fFireSystems CTM-530 Series Protectowire Interface Module V with Confirmed Temperature Initiation (CTITM) Features General The CTM-530 is a detection control module that acts as an interface between a main fire alarm control panel detection circuit or addressable node and Protectowire Type CTI Linear Heat Detector. The module provides one (1) supervised detection circuit that may be field wired for either Class A (Style D) or Class B (Style B) service. The alarm initiating circuit is capable of operating up to 4000 feet (1220 meters) of Protectowire Type CTI Linear Heat Detector. The CTM-530 initiating circuit currently does not support other types of normally open contact alarm initiating devices. Description The CTM-530 operates using Protectowires patented CTI Confirmed Temperature Initiation technology. When paired with Pro-tectowire Type CTI Linear Heat Detectors, the module can distinguish between a mechanical short in the linear heat detector and a thermal alarm activation thereby greatly reducing the risk of false alarms. This multi-criteria detection method provides for short circuit discrimination, a feature previously unavailable for digital type linear heat detectors. Provides a single zone interface for Protectowire Type CTI Linear Heat Detectors Patented technology can distinguish between mechanical shorts and thermal alarm conditions (Short Circuit Discrimination) Integrated Protectowire Alarm Point Location Meter with field calibration 420 LED backlit LCD display Modbus over RS-485 communications 4-20mA outputs for Status and Alarm Point Location 64 Event History Log (FIFO) Optional intrinsically safe detection circuit available for use in hazardous locations. The CTM-530 is designed for easy installation and is optionally available in a NEMA-4X rated enclosure for mounting outside of the host fire alarm control panel or remotely near the hazard to be protected. In order to ensure proper operation, each CTM-530 module requires regulated resettable external power which is normally provided by the host fire alarm panel. Each module contains a green "Power-On" LED indicator, one (1) red "Alarm" LED indicator, one (1) yellow "Trouble" LED indicator and one (1) yellow "short fault" LED indicator. One (1) set of Form C alarm contacts, one (1) set of Form C trouble contacts and one (1) set of Form C short circuit fault contacts are also provided to connect the unit to the host fire alarm panel. The module also provides Modbus over RS-485 communications and two 4-20mA outputs, one which allows monitoring of the module status and the other for monitoring alarm point location information. The standard CTM-530 module contains a built in Protectowire Alarm Point Location Meter. This meter will automatically display the distance from the beginning of the detector run to the heat actuated (shorted) portion of the detector. The Alarm Point Location Meter can be programmed to display in either standard units (Feet) or metric units (Meters). The Protectowire company, Inc., 60 Washington Street, Pembroke, MA 02359 I 781-826-3878 I protectowire.com SIGNALING .'Z _ © copyright 2022, The Protectowire company, Inc. All rights reserved. " j Page 1 APPROVED LISTED PROVC1OWIRE® preSys&ms The meter display provides a simple 'on screen" calibration procedure allowing the measurement to be field calibrated to the installed detector length and ambient temperature for optimal accuracy. Specifications Electrical Power input - Regulated 12 to 24 VDC (+10% / -15%) @1.6 Watt Power Limited, onboard surge and EMI protection devices Inputs One initiating device circuit capable of monitoring up to 4000 Feet (1220 Meters) of Protectowire Type CTI Linear Heat Detector. For all CTI type detectors, twisted "1" type thermocouple grade extension wire is required for use as interconnecting cable on the detection circuit. Minimum conductor size is 20 AWG (0.812 mm), or as required by local code. Environmental Ambient temperature range: Standard version (with integrated LCD display) -200 to 120°F (-290 to 49°C) FM tested to 140°F (60°C) max Humidity: Max. 95% non-condensing Indicators 4x20 Character LED backlit LCD display One green "Power" indicator One red "Alarm" indicator One yellow "Fault" indicator One yellow "Short Fault" indicator Relay Outputs (Rated 1 amp @ 24VDC Resistive) One (1) set of Form C (SPDT) Fault Contacts One (1) set of Form C (SPDT) Short Fault Contacts One (1) set of Form C (SPDT) Alarm Contacts Board Assembly Dimensions 6" W x 4" H x 1.5" D (15.24cm x 10.16cm x 3.8cm) Mounting holes #4 holes at 5.5" x 3.5" (13.97cm x 8.89cm) spacing DATA SHEET 4-20mA Outputs One(1) 4-20mA Output for module status One (1) 4-20mA Output for Alarm Point Location Readings (CTM-5p.JEnclosure Specifications 8"H x 6W x 1.5"D (15.24cm x 10.16cm x 3.8cm) Add 1.6" (4cm) to overall height for external mounting feet. Clear full view door NEMA 4X Rated (Rating UL listed only) Option I - Intrinsically Safe Detection Circuit Option I provides an intrinsically safe Class B detection circuit for use in those areas classified as hazardous. This feature utilizes one shunt diode barrier per zone and is FM Approved for Class I, II and Ill, Division 1, Groups A, B, C, D, E, F and G; Class I, Zone 0, AEx ia IIC 16 -29°C !~ Ta !~ +60°C Ga. CTM-530E-1 Enclosure Specifications 10.5" H x 8.5" W x 4.5" D (27cm x 21.5cm x 11.4cm) Add 1.6" (4cm) to overall height for external mounting feet Clear full view door NEMA 4X Rated (Rating UL listed only) 4-2OmA Output Information Description The CTM 530 provides two 4-20mA outputs that allow for monitoring of the module status and active alarm point location reading. These outputs are intended for annunciation purposes only. Module monitoring is intended to be accomplished using the on-board dry contacts connected to a listed or approved fire detection control panel initiating device circuit. Consult Manual for detailed output levels for each status loop. Modbus over RS-485 Description The CTM-530 interface module provides integrated Modbus over RS-485 communications. Each module can be configured as a Modbus slave device on an RS-485 network. Once configured to communicate on a network, each module can be polled by a master device for a variety of module specific data. A master device, such as a PLC (Programmable Logic Controller) can monitor the status of one or more modules and take actions based on their status. Modbus over RS-485 communication is a convenient method for utilizing detector status information to implement equipment shutdown or other automation events. Note: All specifications subject to change with out notice. Ordering Information Model No. Description CTM-530 Interface Module for Protectowire Type CTI with LCD display and navigation buttons. (CTM-53QE Interface Module for Protectowire Type CTI with LCD display and navigation buttons mounted in a NEMA-4X (1P66) Enclosure. CTM-530E-1 Interface Module with ISB for Protectowire Type CTI with LCD display and navigation buttons mounted in a NEMA-4X (1P66) Enclosure. The Protectowire company, Inc., 60 Washington Street, Pembroke, MA 02359 I 781-826-3878 I protectowire.com © Copyright 2022, The Protectowire Company, Inc. All rights reserved. Page 2 1 DS9247-0322F ..•, CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL lJjI FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7270-0854:0105 CATEGORY: 7270 - HEAT DETECTOR LISTEE: Protectowire 60 Washington Street, Pembroke, MA, 02359 Contact: Goggin,Jim (781) 826-2045 Email: jgoggin@protectowire.com DESIGN: ______ Model CII Linear Heat Detectors an(CTM-536) nterface Module. Model designation identifies operating temperature ratings: *CTl 135 XLT (135°F)CTl-155 (155°F), CTI-190 (190°F), CTI-220 (220°F), CTI- 280 (280°F) and CTI-356 (356°F). Models may have suffixes R or X for alternate outer jacket materials. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 or 24 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, operating temperature and FM label. APPROVAL: Listed as linear heat detectors for use with listed fire alarm control panels. *A CTM-530 Module is required to supervise all CTI Linear Heat Detectors. Refer to manufacturer's Installation Manual for details. NOTES: *Revision 06-12-20 vww This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/12/2022 Listing Expires: 06/30/2023 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 1 of 1 LwJ1ftvaIIifle ~FM jrovais Electrical Signaling Electrical protective signaling systems are configurations of components used to produce alarm signals indicative of fire, smoke, sprinkler waterfiow or other emergency and to produce supervisory signals indicative of conditions needing attention with respect to protection equipment or watch service. System configurations are classified according to where and how the signals are received. The categories are commonly designated as local, municipal, remote station, proprietary, emergency voice/alarm communication, emergency communication, and central station. Auxiliary systems are either local or proprietary systems interconnected with a municipal system. This category presents the major system component categories and the integrated system configurations. The selection of components to form a hybrid system should be made only by those skilled in system design. Also, the suitability of any system application should be judged on the basis of the hazard(s) being protected. Alarm Signal Initiating Devices Alarm signals are initiated either automatically or manually. Automatic detectors respond to changes in characteristic phenomena associated with fire or other emergency conditions. Fire Detection, Heat-Actuated Heat sensitive devices may be either "spot" or "line" type and operate at a fixed temperature or on a rapid increase in temperature (rate-of-rise). Some detectors combine the fixed and rate sensitive principles. The spacing guides listed are indicative of each detectors relative sensitivity and, in each case, the spacing guide is the maximum recommended separation between detectors for smooth-ceiling installations. For a given temperature rating, a fixed-temperature detector which has a 30 ft (9 m) listing and one which has a 15 ft (5 m) listing will both respond at approximately the same time to a geometrically growing fire if each is installed at its listed spacing. FM Approved rate-of-rise detectors all have 30 ft (9 m) listed spacings, the maximum separation recommended by FM Approvals. Installation of heat detectors at less than maximum spacing is necessary: to achieve earlier response; to compensate for ceiling obstructions such as beams and joists; and to compensate for ceiling heights greater than 15 ft (5 m). Proper location and use of heat detectors involves consideration of ceiling construction, the location of partitions, the maximum normal room temperature, heat produced by the occupancy, and whether detector function is to warn occupants or to automatically actuate protection equipment. Refer to Standard 72-1993 of the National Fire Protection Association and design specifications published by jurisdictional authorities, as appropriate. Series CTI Linear Heat Detectors Series CTI (Confirmed Temperature Initiation) Linear Heat Detectors used with CTM-530(LT) Interface Module. (CTM-5l, CTM-530-(LT)EI Interface Module is associated apparatus with intrinsically safe connections to Class I, II and lIIDMion 1, GroLJpsA, BC, D, E, F and G; [AEx ia Ga] IIC hazardous (classified) locations. Series CTI Linear Heat Detectors and tZB-HD-5Q6 Zone Boxes are intrinsically safe for use in Class I, II and Ill, Division 1, Groups A, BC, D, E, F and G; Class I, Zone 0AEx ia IIC T6 Ga -29'C:5 Ta 15 +49°C hazardous (classified) locations when connected via the CTM-530-El or CTM-530-(LT)EI in accordance with Control Drawing 1L1622. Model designation identifies operating temperature rating: CTI-155 {155°F (68°C)), CTI-190 (190°F (88°C)}, CTI-220 (220°F (105°C)), CTI-280 (280°F (138°C)), and CTI-356 {356°F (180°C)). Suffix, R or X, is added for alternate outer jacket materials. Each cable is a continuous line type open circuit detector that shorts when in an alarm condition. Spacing guide for the cables: CTI-155 and CTI-190, 30 x 30 ft (9.1 x 9.1 m); CTI-220 and CTI-280, 25 x 25 ft (7.6 x 7.6 m). CTI-356 is intended for proximity detection only. CTM-530(LT) Interface Module distinguishes between a mechanical short in the CTI heat detector and thermal alarm activation. CTM-530(LT) operates on 12 or 24 V dc and provides relay and 4-20 mA outputs for connection to a compatible Approved control. CTM-530 operating temperature range is -20°F (-29°C) {-40°F (-40°C) for LT version) to 120°F (490C). Company Name: liThe Protectowire Co., Inc Company Address: 1160 Washington St., Pembroke, Massachusetts 02359, USA' Company Website: 11http://orotectowire.com New/Updated Product Listing: No Listing Country: United States of America Certificate Number: Certification Type: FM Approved © 2007-2018 FM Approvals. All rights reserved. I of 1 PROTFi6y!iwORE® DATA SHEET [;\ Linear Heat Detection in Refrigerated Storage Areas SPECIAL HAZARD APPLICATION The Detector Freezer and cold storage facilities present unique fire protection challenges. The cold, extremely dry environment compounded with the various combustibles including food products and packing materials are commonly ignited during lighting, refrigeration, and/or other equipment failures. Further, false activation of pre-action sprinkler systems can result in substantial downtime and financial loss. The Protectowire CTI Series provides the only fixed temperature digital linear heat detector that offers short circuit discrimination and the most dependable and cost-effective fire detection option for refrigerated storage applications. Unlike conventional digital linear heat detectors, damage to the CTI Series Linear Heat Detector typically will not result in false alarms. The patented CTI Series detector design incorporates thermocouple technology to confirm temperature at the location of the fault reducing false alarms. This proprietary feature assures that only heat activated shorts reports as alarm conditions. This reduces the possibility of false discharges in double interlocked pre-action sprinkler systems typically employed in freezers. The harsh environments of cold storage warehouse demand a robust detector with low moisture absorption and excellent performance at extremely low temperatures. The CTI-135-XLT is specifically designed to meet these demands and has the lowest activation temperature for digital linear heat detectors at 135°F (57°C) currently available in the market. Protectowire CTI/CTM Series Features: CTI-135-XLT is FM approved and UL listed to -60°F(-51°C) and specifically designed for the harsh environment of refrigerated storage applications. The CTI-135-XLT Detector meets the FM Loss Prevention Data Sheet 8-29 guidelines for Refrigerated Storage Facilities. Mechanical damage to the CTI Series Linear Heat Detector will only cause a short fault. The CTM-530(E) is listed to -20°F (-29°C) and the CTNI-230 (E) is listed to -40°F (°C). The CTM Interface modules are a 4-wire device compatible with most control panels and/or addressable modules. The status and location of the short fault or heat event is displayed on the CTM-530(E) Module's LCD screen and can be communicated via 4-20mA outputs. Modbus via RS-485 output provides module status (standby, fault, short fault, and alarm), alarm point location, and temperature at the point of alarm or short fault. The CTM-530 LCD will actively display the location in feet (or meters) and temperature in Fahrenheit (or Celsius) of any short fault or alarm condition. SIGNAUNG c®us LISTED APPROVED An ISO 9001: Registered Company TYPICAL RACK PLACEMENT WITH PROTECTOVURE MOUNTED ON RACK PLAN VIEW UPPER LEVEL OF PROTECTOWIRE SPRINKLER PIPE UPPER LEVEL LOWER LEVEL OF PROTECTOWIRE !1 SPRINKLER PIPE LOWER LEVEL FROM PREVIOUS RACK TO NEXT RACK UPPER LEVEL LOWER LEVEL ZONE BOX ZONE BOX ONE RUN OF PROTEC1 USING AJO-IAT EACH SPRINKLER LEVEL DETECTOR MAY BE MC PN1ALI.E L TO OR ONE SECTION ABOVE EACH SPRINKLER PIPE LEST SPRINKLER PWIS FEED CABLE = ZONE BOX ZB-HDS.00) = PROTECTOWIRE CTI.135.XLT FROM PREVIOUS ELEVATION VIEW RACK-- _________ TO NEXT (T JRACK The CTM Modules The Protectowire CTM Series detection modules provide an interface between a host fire alarm control panel IDC, or addressable node, and Protectowire CII Series Linear Heat Detectors. The CTM-230 and CTM-530 modules contain one (1) field selectable Class A (NFPA Style D) or Class B (NFPA style B) detection circuit capable of monitoring up to a total of 4000 feet (1220 meters) of CII detector and Type T thermocouple extension grade feed cable. Also included are alarm, fault, and short fault Form C relay contacts for connection to any listed or approved host fire detection monitoring system. The CTM-530 has the enhanced features of an LCD graphical display, navigation keypad, 4-20ma outputs respectively for status, and alarm point location, history log (64 entry, FIFO), as well as Modbus over RS-485. The Modbus-485 output provides the CTM Module status, temperature, and alarm/ short fault location. Please see the CTM-230 and CTM-530 Manuals for additional information. Installation Guidelines The detectors must be installed in continuous runs without taps or branches in accordance with applicable sections of NFPA 70 National Electrical Code, NFPA 72 National Fire Alarm Code, or as determined by the local authority having jurisdiction. It is recommended that Protectowire CII-135-XLI Detector be installed at every level of the sprinkler piping. For single row and double row racks, one line of detection cable is needed at each in-rack sprinkler level. Locate the linear heat detector cable in the transverse or longitudinal flue space and attach it to a horizontal load beam at the sprinkler line level. For multiple-row racks, a line of detection cable is needed for each in-rack sprinkler line at each level. With numerous types of rack systems in use today, the linear heat detector configuration layout may vary based on the type of racking system at each facility. Protectowire should not be installed on sprinkler piping for in-rack systems due to incidents of mechanical damage from fork lift trucks or falling pallets and cartons. We suggest adhering to the guidelines from Factory Mutual (FM) Loss Prevention Data Sheet 8-29 for Refrigerated Storage Facilities and consult the authority having jurisdiction for any local requirements. To ensure a trouble-free installation, only Protectowire supplied or recommended fasteners should be used. Our supplied fasteners are generally designed to lightly clamp the detector which enables tension to be applied progressively. The use of non recommended fasteners may physically damage the detector and in some cases may void the detector's warranty. The JD-1 Stainless Steel Mounting Clip is typically well suited for the freezer and cold storage installations. This clip may be used for ceiling, pipe, or wall mount applications, as well as all corners. It is designed specifically to support our detectors and allows the detectors to slide in easily during installation and slide out for any future repairs. The clips can be mounted in advance of running the cables, for ease and speed of installation. Protectowire CTI-135-XLI Series Linear Heat Detector is a component of a family of fire detection systems manufactured by Protectowire FireSystems. Protectowire Linear Heat Detector (n-Rack Mounting Detector mounted centered on back of beams at same level crone level above each sprinkler section. Protectowire Linear Heat Detector In Rack 5 Located in Clip Fastener Eveiy5Min. N. SIGNALING The Protectowire Company, Inc., 60 Washington Street, Pembroke, MA 02359 I 781-826-3878 I protectowire.com © Copyright 2020, The Protectowire Company, Inc. All rights reserved. C CQIL Page 2 DS 9300A-1220 LISTED APPROVED FIR OTFi6y~thew OIRE® " DATA SHEET Protectowire Linear Heat Installation Accessories / Part#: PWTX-200 / PWTX-500 CTI Series Extension Cable. Installation Requirements The PWTX extension grade Type T Thermocouple must be used as interposing cable between the CTM Series Modules and CTI Type Linear Heat Detectors. All CTI zone box connections and end of the line terminations must employ Type T Thermocouple devices. Use of copper devices will create parasitic Thermocouple junctions that will impeed proper operation of the CTM Series Modules. Standard copper wire and connections are not suitable for use in CTI applications. Polarity must be observed. Information Thermocouple grade extension cable. Material: 2 conductor 20 AWG solid type "TX" thermocable twisted pair. Color & Pairing: Red (constantan) with blue (copper) Temperature: -90°F (-67°C) to 400°F (204°C) Outer Jacket: FEP Teflon - UV, corrosion and weather resistant For use in non-classified hazards only. PWTX extension cable available in 200ft (60m) or 500ft (152m) spools. The Protectowire Company, Inc., 60 Washington Street, Pembroke, MA 02359 U.S.A I 781-826-3878 I protectowire.com © 2021, The Protectowire Company, Inc. All rights reserved. ISO 9001 Registered company Page ii D59317 -0321 ZB-H D-5-QC CTI LINEAR HEAT DETECTOR HEAVY DUTY ZONE BOX DATA SHEET 9265 4-2-2015 The illustration below shows the typical field wiring connections for Protectowire Linear Heat Detector type CII. Due to the Thermocouple characteristing of the detector, electrical polarity must be properly observed. Also, the DRTB-T-2 connector block must be employed in order to maintain the measurement accuracy of the thermocouple component of the detector. Thermocouple type T extention cable must be employed as interposing cable on the detection circuit. Note: DRTB-T-2 terminal (17 markings: Copper - CU = (+) Constantan - CO = (-) EFIM: 4.00' (102mm) (2) EACH #10-32 BRASS INSERTS AND STAINLESS STEEL CAPTIVE COVER SCREWS L•:o THE ABOVE ENCLOSURE IS DESIGNED FOR USE MOUNTING PANEL DETJL IN HIGHLY CORROSIVE ATMOSPHERES. THE 481 x 4.81 ENCLOSURE IS MOLDED FROM A REINFORCED (1fl24mm) x (122.24mm) POLYESTER MATERIAL WHICH HAS EXCELLENT CHEMICAL RESISTANCE. MOUNTED INSIDE OF CABINET WEIGHT: 2.0 LBS. SR-502 Series Strain Relief connectors sold separately INSTALL IN ACCESSIBLE LOCATION PREFERABLY NOT MORE THAN SIX FEET ABOVE THE FLOOR. *ELR ONLY INSTALL AT LAST BOX (END OF LINE) FOR CLASS B DETECTION WIRING FOR CLASS A, RETURN TO CTM MODULE USING TYPE "T' THERMOCOUPLE EXTENSION CABLE IF NECESSARY. 60 Washington Street, Pembroke, MA 02359 '781-826-3878 FAX 781-826-2045 'www.proteCtowire.com Special hazard fire alarm systems PROTFi6ylclms ORE® "/'/" DATA SHEET Protectowire Linear Heat Instaggation Accessories Part#: SR-502I 7 Strain Relief! Cable Gland. DOME FITTING 0-RING LOCKING NUT TORQUE 1.5 TO 3 TURNS PAST FINGER TIGHT i/o (ZZ mmj I 1.)Mmjl Information Material: Nylon 6/6:PVC grommet. RoHs compliant. Temperature: -40 OF (-40 °C) to 212 OF (100 °C) Cable Outer Jacket Diameter Range: 0.08" to 0.24" (2 mm to 6 mm) Rating : Watertight and oiltight Rating: UL Listed NEMA 4 & 6P. Thread type size for dome fitting and locking nut is 3/8" NPT. CLEARANCE HOLE DIAMETER: 27/32"(21 mm) The Protectowire company, Inc., 60 Washington Street, Pembroke, MA 02359 U.S.A I 781-826-3878 I protectowire.com © 2021, The Protectowire company, Inc. All rights reserved. ISO 9001 Registered company Page 1 1 D59239A- 0221 19 PROT&OW IRE ® HreSystems Protectowire Linear Heat Installation Accessories Part#: JD-1 Clip A General Purpose Mounting Device. DATA SHEET RO.08 0.11" 0.25 0.23 [ I 0.015 1.00 i—I II 0501 II II D-r- Diameter 0.25" *All dimensions are approximate and shown in inches. Information Stainless steel linear heat detector 'U" type mounting clip with 1/4" mounting hole. Compatible with any Protectowire Linear Heat Detector. Material: 304 stainless steel Temperature: -76°F to 572°F (-60°C to 300°C) LHD Cable Diameter Range: (0.145" to 0.165" (3.7mm to 4,2mm) Insertion Force: Approx. 2-3 lbs. (9-13 Newtons) Mounting Hole Diameter: 0.25" (6.35 mm) Resistance: UV, corrosion and weather all excellent Maximum Recommended Spacing: 5 ft (1.5 M). The Protectowire company, Inc., 60 Washington Street, Pembroke, MA 02359 U.S.A I 781-826-3878 I protectowire.com © 2020, The Protectowire company, Inc. All rights reserved. ISO 9001 Registered company Page ii D59304- 0320 PROOR OW IRE ® " DATA SHEET Systems Protectowire Linear Heat Onstailationi Accessories Part#: SR-5o21 I Strain Relief / Cable Gland. DOME FITTING 0-RING LOCKING NUT TORQUE 1.5 TO 3 TURNS PAST FINGER TIGHT ( ) I9/i2"(15 mm) Information Material: Nylon 6/6:PVC grommet. RoHs compliant, Temperature: -40 °F (-40 °C) to 212 °F (100 °C) Cable Outer Jacket Diameter Range: 0.08" to 0.24" (2 mm to 6 mm) Rating : Watertight and oiltight Rating: UL Listed NEMA 4 & 6P. Thread type size for dome fitting and locking nut is 3/8" NPT. CLEARANCE HOLE DIAMETER: 27/32(21 mm) The Protectowire company, Inc., 60 Washington Street, Pembroke, MA 02359 U.S.A I 781-826-3878 I protectowire.com © 2021, The Protectowire company, Inc. All rights reserved. ISO 9001 Registered company Pagel 1D59239A- 0221