HomeMy WebLinkAbout2793 ELMWOOD ST; ; AS1401589126/24, 8:26 AM AS140158 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2793 ELM WOOD ST Permit Type: SPRINK Parcel No: 1562316700 Lot #: 0 Reference No.: Permit No: AS140158 Status: ISSUED Applied 6/27/2014 Approved: 7/1/2014 Issued: 7/1/2014 PC #: Inspector: Project Title: HOLLERAN RESIDENCE SPRINKLER SYSTEM FOR NEW SINGLE FAMILY RESIDENCE W/ ATTACHED GARAGE, RAISED DECKS, SPIRAL STAIR AND DETACHED CARPORT Applicant: ALPHA FIRE PROTECTION 500 HACIENDA DR #180 VISTA, CA 760-727-6993 Owner: HOLLERAN FAMILY TRUST 07-15-97 2793 ELM WOOD ST CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 404 0 404 about:blank ill ALPHA FIRE PROTECTION Mio5-g RESIDENTIAL FIRE SPRINKLER SYSTEM DATA BLOCK: DATE: 6119114 JOB ADDRESS: 2793 ELMW000 STREET CARLSBAD, CA. ASSESSOR'S PARCEL NUMBER: 156-231-67 OWNER'S NAME: WILLIAM & MARY HOLLERAN OWNER'S ADDRESS: SAME OWNER'S PHONE NUMBER: GENERAL CONTRACTOR'S NAME: MIRA BEu..A DESIGN GENERAL CONTRACTOR'S ADDRESS: GENERAL CONTRACTOR'S PHONE NUMBER: SPRINKLER CONTRACTOR'S NAME: ALPHA FIRE PROTECTION SPRINKLER CONTRACTOR'S ADDRESS: 4203 GENESEE AVE #103-424 SAN DIEGO, CA 92117 SPRINKLER CONTRACTOR'S PHONE NUMBER: (760) 727-6993 CALIFORNIA STATE LICENSE #582853 EXPIRES 12-31-2015 HYDRAULIC NOTES: WATER METER SIZE: 1" METER ELEVATION: - 150 AMSL PRESSURE AT METER: 45 PSI FLOW (GPM): HOUSE SIDE OF METER: 50 GPM PAD ELEVATION: 144' PRESSURE AT PAD: 48 PSI PIPE LENGTH: METER To PAD: 45' Pipe Type/Size: PVC - 2" SPRINKLER TABLE: CARLSBAD WATER DEPT. (760) 438-2722 DATE: 6-18-14 3PM SYMB COMPANY & MODEL ORF TYPE TEMP K-FAT CANOPY QT • Tyco LF-ll 1/2 SSP RR Sin#_2524 165 Degree 4.9 White Concealed 21 o Tyco -FRB Sin # 3231 1/2 SSP 200 Degree 5.6 flute Recessed/none 6 I Total 1 27 PIPE TABLE: TYPE MFG MODEL AREA OF USE CPVC Tco BLAZEMASTER SYSTEM STEEL ALLIED SCHEDULE 40 NONE USED COPPER MULLER TYPES M & L SUPPLY PVC SPEARS SCHEDULE 40 SUPPLY NOTE: PIPE MUST BE U.L. OR F.M. LISTED FOR RESIDENTIAL FIRE SPRINKLER USE. PLANS MUST STATE: "PIPE WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS" "A COPY OF PIPE MANUFACTURER'S INSTALLATION INSTRUCTION PAMPHLET MUST BE KEPT ON-SITE." Alpha Fire- Hydraulic Cakulations Contract Name: IOU, 1Z,O Sheet / of 'Calculafion for: 2- I1I2 Pt) W6' Date: Nozzle Type & Location Flow In GPM — Pipe Size Inches Fittings And Devices Pipe Fittings Total Friction Loss psi/ft Required Pressure psi Elevation Node Notes jtco q Q 1 3 Type4O/( Diameter 3 C-Factors 'O . Ln / 0q 1/L/ Pt - 6 16V 773 Ft I0 Pf /1 (C)1/ Tot // Pe q Q Type Diameter C-Factor La ptg(,ot/ Ft Pf Tot Pe / (I q Q 12 Type CPVC Diameter C-FactorJ$6 it, Ln 2 a q t, LI Pt -7--- 4 -1i3 Ft 10 Pf Tot I' Pe q Q 13, Type cP Li C Diameter C-Factor! V 71 La 9 05o? Pt (0 L( c, 7"' / 2- Ft I Pf 3 / Tot / (f) Pe t(D LI q Q 'j Type C.j°V C. Diameter ( C-Factor I $) i-f . e/v Ln 4 Pt , 3 ~ ) 70 P. I LI 7 q-3 - Ft -'fl. Tot Pe 7,3(o q Q , (ç Type M c Diameter I C-Factor I D V( Ln ..j 3 I Pt /45 I Th Ft 1 3.5 Pf Tot 17, 5 Pe , 7 q Q '2 L Type 1,1 Diameter / C-Factor 10 ç- La (p 'ii' Pt 7,S. o F A4 10 '' 6•1' 's" IV Ft L. $ Pf 2. ..Z- Tot /0,5 Pe (27 / L/ 3 q Q 31 Type put Diameter 4, C-Factor 150 La Lj5 00 -75 Pt3g,q5 Ft - Pf L( Tot 11 Pe+347 3 150 q Q 3f Diameter"! Type C-Factor Ln If / Pt 2-, H M[Z2 / O Ft 1 Tot Pc q Q 3 / Type }(CL) Diameter )• C-Factor /50 2lC La 17, 50G Pt32-(P .1 Ft Pf i.j / Tot 1 6' Pe 1 ,30 / L./ 7 q Q Type Diameter C-Factor Ln Pt3O7 Ft Pf Tot Pe q Q Type Diameter C-Factor La Pt Ft Pf Tot Pe 4 AS 14-o [5-F tqCJ7 Fire Suppression & Building Products Technical Services 800-381-9312 I +1-401-781-8220 www.tyco-fire.com 11 papid esponse HOME FIRE SPRINKLER SYSTEM Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 49 K-Factor General Description The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) are decora- tive, fast response, fusible solder sprin- klers designed for use in residential oc- cupancies such as homes, apartments, dormitories, and hotels. The Cover Plate/Retainer Assembly con- ceals the sprinkler operating compo- nents above the ceiling. The flat profile of the Cover Plate provides the optimum aesthetically appealing sprinkler design. Additionally, the concealed design of the Series LFII Residential Flat-Plate Con- cealed Pendent Sprinklers provides 1/2 inch (12,8 mm) vertical adjustment. This adjustment provides a measure of flex- ibility when cutting fixed pipe drops. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are in- tended for use in the following systems: per NFPA 13D, wet pipe residential sprinkler systems for one- and two- family dwellings and mobile homes; per NFPA 13R, wet pipe residential sprinkler systems for residential oc- cupancies up to and including four stories in height; and per NFPA 13, wet pipe sprinkler sys- tems for the residential portions of any occupancy. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. The Series LFII Residential Flat-Plate Concealed Pendent Sprinkler has a 4.9 (60,5) K-factor that provides the required residential flow rates at reduced pres- sures, enabling smaller pipe sizes and water supply requirements. This sprinkler has been designed with heat sensitivity and water distribution characteristics proven to help in the con- trol of residential fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap protects the sprinkler during ceiling installation or finish. After ceiling installation is com- plete, the Protective Cap is removed and the Cover Plate/Retainer Assem- bly is installed. Removing the Protec- tive Cap is required for proper sprinkler performance. L(.1tL.I The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (1-Y2524) described herein must be installed and maintained in compliance with this doc- ument and with the applicable standards of the National Fire Protection Associa- tion, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The in- stalling contractor or sprinkler manu- facturer should be contacted with any questions. Model/Sprinkler Identification Number (SIN) TY2524 Technical Data Approvals UL and C-UL Listed NSF-61 Certified The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are only listed with the Series LFII Concealed Cover Plates having a factory-applied finish. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/psi° (70,6 LPMJbar1 ) Temperature Rating Sprinkler: 160°F (71°C) Cover Plate: 139°F (59°C) Vertical Adjustment 1/2 inch (12,7 mm) Finishes Refer to the Ordering Procedure section. Physical Characteristics Cover Plate/Retainer Assembly: Cover Plate .............Copper Ejection Spring .... Stainless Steel Retainer ................Brass Page 1 of 6 OCTOBER 2010 TFP443 TFP443 Page 2 of 6 Horizontal Ceiling Sloped Ceiling Sloped Ceiling Minimum Flow0'tand Minimum Flow(b) and Minimum Flow(b) and Residual Pressure Residual Pressure Residual Pressure Maximum Maximum (Maximum 2-inch rise (Greater than 2-inch rise (Greater than 4-inch rise Coverage Spacing for 12-inch run) up to maximum 4-inch up to maximum 8-inch Area N rise for 12-inch run) rise for 12-inch run) 160°F (71°C) 160°F (71°C) 160°F (71°C) Sprinkler Sprinkler Sprinkler 12' x 12' 12' 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) (3,7 m x 3,7 m) (3,7 m) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 14'x 14' 14' 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) (4,3 m x 4,3 m) (4,3 rn) TO psi (0,48 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 16 x 16' 16' 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) (4,9 m x 4,9 m) (4,9 m) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 18'x 18' 18' 17 GPM (64,3 LPM) 22 GPM (83,3 LPM) 22 GPM (83,3 LPM) (5,5 m x 5,5 m) (5,5 m) 12.0 psi (0,83 bar) 20.2 psi (1,39 bar) 20.2 psi (1,39 bar) 20' x 20' 20' 20 GPM (75,7 LPM) 24 GPM (90,8 LPM) 24 GPM (90,8 LPM) (6.1 m x 6,1 m) (6,1 m) 16.7 psi (1,15 bar) 24.0 psi (1,65 bar) 24.0 psi (1,65 bar) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which Hydraulic Design section under the Design Criteria are stated. The Minimum Flow requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to "Hydraulic Design' in the Design Criteria section for details. TABLE A SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA WET PIPE SYSTEMS Sprinkler/Support Cup Assembly: Body ...................Brass Cap ...................Bronze Saddle ..................Brass Sealing Assembly .......Beryllium Nickel w/ Teflon' Soldered Link Halves ......Nickel Lever ..................Bronze Compression Screw .......Brass Deflector ...............Bronze Guide Pin Housing........Bronze Guide Pins .............Bronze Support Cup ..............Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup As- sembly. At this point, the Deflector, sup- ported by the Guide Pins, drops down to its operated position. The Solder Link Element of the Sprinkler/ Support Cup Assembly is comprised of two (ink halves that are soldered togeth- er with a thin layer of solder. When the rated temperature is reached, the sol- der melts and the two link halves sepa- rate, allowing the sprinkler to activate and flow water. 1 Registered trademark of Dupont Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) are UL and C-UL Listed for installation in ac- cordance with the following criteria. When conditions exist that are outside the scope of the provided criteria, re- fer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that maybe accept- able to the Authority Having Jurisdiction. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers must not be used in applications where the. air pressure above the ceiling is greater than that below. Down drafts through the Support Cup can delay sprinkler op- eration in a fire situation. System Type Only wet pipe systems may be utilized. Hydraulic Design Table A provides the minimum required sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required dis- charge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: flow rates given in Table A for NFPA 13D and 13R as a function of tem- perature rating and the maximum al- lowable coverage area minimum discharge of 0.1 GPM/ sq. ft. over the "design area" com- prised of the four most hydraulically demanding sprinklers for actual cov- erage areas protected by the four sprinklers Obstruction To Water Distribution Locate sprinklers in accordance with the obstruction rules of NFPA for residential sprinklers as well as obstruction criteria described within TYCO technical data sheet TFP490. Operational Sensitivity Install sprinklers relative to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprin- klers cannot exceed the length of the coverage area (Table A) being hydrau- lically calculated; for example, a maxi- mum of 12 feet for a 12 ft. x 12 ft. cov- erage area or 20 feet for a 20 ft. x 20 ft. coverage area. TFP443 Page 3 of 6 BODY (1/2" NP CAP SADDLI EALING SEMBLY INKLER ENCHING ASREA PRESSION CREW EVER DER LINK EMENT SUPPOF CUP Wfl ROLL FOR THREAC GUIDE PIN GUIDE F HOUSIt' rRI irrr THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING LECTOR ERATED I JSITION) SPRINKLER/SUPPORT CUP ASSEMBLY RETAINER WITH THREAD DIMPLES CD C) fl EJECTION H SPRING WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 18 SPRINKLER WRENCH SOLDER -' COVER PLATE/RETAINER -_. COVER TAB ASSEMBLY PLATE FIGURE 1 FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) ASSEMBLY 2-1/2' DLA. SPRINKLER- &-l i , .12,7 mm) FACE OF (63,5 mm) SUPPORT CUP v 14 ASSEMBLY 1/2'EADED SPRINKLER / OPERATE NPT STMENT FIfiNG SPRINKLE COVER (47,6 mm RETAINEF /8 GAP ±3,2 mm) (3,2 mm) PLATE 7/8' (22,2 COVER- SPRINKLER- MOUNTING RETAINER SUPPORT CUP 3/16" j SURFACE , 1-1/8' (28,6 ASSEMBLY ASSEMBLY I (4,8 mm) 3-3/16' DIA. DISPOSABLE (81,0 mm) TIP PROTECTIVE CAP DEFLECTOR IN OPERATED POSITION FIGURE 3 PROTECTIVE CAP AND ACTIVATED DEFLECTOR INSTALLATION DIMENSIONS TFP443 Page 4 of 6 .1 Installation The TYCO RAPID RESPONSE Series LFli Residential Flat-Plate Concealed Pendent Sprinklers must be installed in accordance with the following instructions. Damage to the Solder Link Element dur- ing installation can be avoided by han- dling the sprinkler by the Support Cup only; that is, do not apply pressure to the Solder Link Element (Figure 1). Obtain a leak-tight 1/2 inch NPT sprinkler joint by applying a minimum-to-maxi- mum torque of 7 to 14 ft.-tbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Cover Plate! Retainer Assembly by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Install pendent sprinklers in the pendent position, with the center- line of the sprinkler perpendicular to the mounting surface. Remove the Protective Cap. With pipe-thread sealant applied to the pipe threads, and using the W-Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler! Support Cup Assembly into the fit- ting. The W-Type 18 Wrench ac- cepts a 1/2 inch ratchet drive. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protective Cap helps prevent dam- age to the Deflector and Guide Pins during ceiling installation and/ or during application of the finish coating of the ceiling. As long as the protective Cap re- mains in place, the system is con- sidered "Out Of Service". After the ceiling has been com- pleted with the 2-1/2 inch (63 mm) diameter clearance hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and discard the Protective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. 6. Screw on the Cover Plate/Retainer Assembly until its flange contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Mounting Cup or the Cover Plate/Retainer As- sembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinkler (TY2524) must be maintained and serviced in accordance with the following instructions. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it con- trols, obtain permission to shut down the affected fire protection system from the proper authorities and notify all person- nel who may be affected by this action. When properly installed, there is a nomi- nal 1/8 inch (3,2 mm) air gap between the lip of the Cover Plate and the ceil- ing, as shown in Figure 3. This air gap is necessary for proper operation of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling needs repainting after sprinkler installation, exercise care to ensure that the new paint does NOT seal off any of the air gap. Failure to do so may impair sprinkler operation. Absence of a Cover Plate can delay the sprinkler operation in a fire situation. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Exercise care to avoid damage to sprin- klers before, during, and after installa- tion. Never paint, plate, coat, or other- wise alter automatic sprinklers after they leave the factory. Never repaint factory-painted Cover Plates. When necessary, replace cover plates with factory-painted units. Non- factory applied paint can adversely de- lay or prevent sprinkler operation in the event of afire. Replace sprinklers that: were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. were modified or over-heated. are leaking or exhibiting visible signs of corrosion. Responsibility lies with owners for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Worldwide www.tyco-fire.com Contacts Series TY-FRB - 28, 42, 56, and 80 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pen- dent, and Recessed Pendent Sprin- klers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY- FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. IL'L•)1DI The Series TY-FRB Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. - — 0-121 i Ii "1l i •i jLJ ,•, - - -.-. Sprinkler Identification Number (SIN) TY1131: Upright 2.8K, 1/2- NPT 1Y1231: Pendent 2.8K, 1/2NPT TY2131: Upright 4.2K, 1/2- NPT 1Y2231: Pendent 4.2K, 1/2" NPT TY3131: Upright 5.6K, 1/2" NPT TY3231: Pendent 5.6K, 1/2- NPT TY4131: Upright 8.0K, 3/4" NPT TY4231: Pendent 8.0K, 3/4" NPT 1Y4831: Upright* 8.0K, 1/2" NPT TY4931: Pendent* 8.0K, 1/2" NPT "Eastern Hemisphere Sales Only MARCH 2OI TFPI7I Alpha Fire Protection Submittal Package Job: 2793 Elrnwood Street Carlsbad, Calif Scope: Provide Fire Sprinklers to a New Residential House To: Greg Ryan @ Carlsbad Fire Prevention From: Alpha Fire Protection 4203 Genesee Ave. #103-424 San Diego Calif. 92117 Cell (760) 917-9058 e-mail: alphafireprotection@hotmail.com Submitted By: Don Riley Cal. Lic. # 582853 AS140158