7720 EL CAMINO REAL; ; FA090054
9/26/24, 8:23 AM FA090054 Permit Data City of Carlsbad Fire Alarm Permit 7720 EL CAM INO Job Address: REAL Permit Type: FALARM Parcel No: 2161241600 Lot #: 0 Reference No.: Permit No: FA090054 Status: ISSUED Applied 12/17/2009 Approved: 12/17/2009 Issued: 12/17/2009 PC #: Inspector: Project Title: SAN DIEGO CULTURE & EDUCATION Applicant: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO CA 760-747-3050 Owner: LACOSTA TOWER LLC C/O THOMSON REUTERS 2235 FARADAY AVE #0 CARLSBAD CA Fees ($) JAdd'I Fees ($)T Total ($) Balance 125 0 125 0 about:blank ill FIRE PROTECTION SYSTEMS Aôôo S4 Existing buildings or structures intended for public assemblies of 10,000 or more persons, which, on or after January 1, 1991, have or subsequently have installed a public address system, shall have an emergency backup power system for the public address system. 907.2.2 Group B. A manual fire alarm system shall be installed in Group B occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge. Exception: Manual fire alarm boxes are not required where the building is equipped throughout with an auto- matic sprinkler system and the alarm notification appli- ances will activate upon sprinkler water flow. 907.23 Group E. A manual and automatic fire alarm sys- tem shall be installed in Group E occupancies with an occu- pant load of 50 or more persons or containing more than one classroom or one or more rooms used for day care pur- pose. When automatic sprinkler systems or smoke detectors are installed, such systems or detectors shall be connected to the building fire alarm system. Exceptions: Manual fire alarm boxes are not required in Group E occupancies where all of the following apply: 1.1. Interior corridors are protected by smoke detectors with alarm verification. 1.2. Auditoriums, cafeterias, gymnasiums and the like are protected by heat detectors or other approved detection devices. 1.3. Shops and laboratories involving dusts or vapors are protected by heat detectors or other approved detection devices. 1.4. Off-premises monitoring is provided. 1.5. The capability to activate the evacuation signal from a central point is provided. 1.6. In buildings where normally occupied spaces are provided with a two-way com- munication system between such spaces and a constantly attended receiving station from where a general evacuation alarm can be sounded, except in locations specifi- cally designated by the fire code official. Manual fire alarm boxes shall not be required in Group E occupancies where the building is equipped throughout with an approved automatic sprinkler system, the notification appliances will activate on sprinkler water flow and manual activa- tion is provided from a normally occupied loca- tion. 907.2.3.1 System connection. When more than one fire alarm control unit is used at the school campus, they shall be interconnected and shall operate all notification appliances. Exception: Interconnection of fire alarm control units is not required when: Buildings that are separated a minimum of 20 feet (6096 mm) and in accordance with the Cal- ifornia Building Code, There is a method of communication between each classroom and the school administrative office approved by the fire enforcing agency. 907.2.3.2 Schoolflre alarms. Except as provided in Sec- tion 907.3, every building used for educational pur- poses, regardless of occupancy classification shall be provided with an app rovedfire alarm system. This provi- sion shall apply to, but shall not necessarily be limited to, every elementary school, high school, community col- lege and university. Exception: Privately owned trade or vocational schools or any firm or company which provides edu- cationalfacilities and instructionsfor its employees. 907.2.3.3 Notification. The system notification shall be consistent with the requirements for audible and visible notification requirements of Section 907 and NFPA 72 as amended in Chapter 35. Audible notification shall com- ply with the American National Standards Institute (ANSI) S3.41 Emergency Evacuation Signal. An audible alarm notification appliance shall be mounted on the exterior of buildings to alert occupants in and around the playground area. 907.2.3.4 Annunciation. Annunciation of the fire alarm system shall comply with the requirements of Section ( 907.9.1. 907.2.3.5 Supervising station. Fire alarm systems shall transmit the alarm, supervisory and trouble signals to an approved supervising station in accordance with NFPA 72. The supervising station shall be listed as either UUFX (Central Station) or UUJS (remote & propri- etary) by the Underwriters Laboratory Inc. (UL) or shall comply with the requirements of standard FM 3011. 907.2 .3.6 Public schools—smoke detectors. 907.2.3.6.1 Automatic detection. Smoke detectors shall be used as the primary method of automatic alarm initiation except, in areas where the environ- ment or ambient conditions exceed smoke detector installation guidelines, another method of automatic detection shall be used. In areas containing sprin- klers, heat detectors may be omitted. Smoke detectors shall be designed, installed and maintained in accor- dance with Section 907 and NFPA 72 as amended in Chapter 45. Smoke detectors shall be located at the ceiling of every room and area, and in "ceiling-plenums" uti- lizedfor environmental air In buildings provided with an approved automatic fire sprinkler system where• the ceiling creates a "ceiling-plenum" or a space above the ceiling for nonenvironmental air, automatic sprinklers shall be installed to protect such spaces of buildings that house and or serve students from kin- dergarten through twelfth grade (K-12) and are sited on a new public school campus as defined in Section 202. () 0 / -... C) 106 2007 CALIFORNIA FIRE CODE LEGAL DESCRIPTION c OWNER LA COSTA TOWER LLC C/O CUSHMAN AND WAKEF ADDRESS TELEPHONE SITE ADDRESS OCCUPANCY CLASSIFICATION OCCUPANT LOAD PARCEL NO.: ZONING: PRESENT OCCUPANCY PROPOSED OCCUOANCY DESCRIPTION OF USE BUILDING AREA CONSTRUCTION TYPE SPRINKLERS PARKING CONTRACTOR NAME ADDRESS TELEPHONE 601 S.. FIGUEROA ST. 47th F 213-955-5100 7720 EL CAMINO REAL SUIT LE1 c5O N/A C VAN CANT SAN DIEGO CULTURE & ED AFTER SCHOOL EDUCATIC 1880 SF VB NO EXISTING QE CONSTRUCTION INC. 13526 CELESTIAL RD, POVd 858-231-6768 SCOPE OF WORK BUILD UP PARTITION WALLS FOR NEW OFFICES AND CLA ADD ON ONE BATHROOM. REWIRING EXISTING LIGHTS AND ADD ON SWITCHES FOF 4, -rh4Me- lob,& cvt'tf be C/"t,,- APPLICABLE CODES: 1. THE 2007 EDITION OF THE CALIFORNIA BUILDING CODE NATIONAL BUILDING CODE (IBC) AND THE 2007 CALIFC 2. THE 2007 EDITION OF THE CALIFORNIA ELECTRICAL CC TIONAL ELECTRICAL CODE (NEC) AND THE 2007 CALIF( -• -- --.-.•.. •I II- #%A1 I'trThJIA &A('UAkII('AI (4 F.HulEppms1Es - FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS 4- SAN DIEGO CULTURE AND EDUCATION ACADEMY 7720 EL CAMINO REAL, SUITE K CARLSBAD CA, 92009 FIRE ALARM SYSTEM () Underwriters Laboratories Inc. ® Northbrook, IL San Jose, CA Melville, NY FApplicant ID No: 892912-001 Service Center No I Expires: 31-MAR-2010 A not-for-profit organization dedicated to public safety and committed to quality service CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply In any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: LONG BEACH, CA Alarm Service Company: (892912-0011 Service Center: (892912-001) GENERAL MONITORING SERVICES INC GENERAL MONITORING SERVICES INC 1127 LOMA AVE 1127 LOMA AVE LONG BEACH CA 90804 LONG BEACH CA 90804 The Alarm Service Company is Listed In the following Certificate Service Categories: File -Vol No CCN Listing Category S7894 -1 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station ***THIS CERTIFICATE EXPIRES ON 31-MAR-2010 "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" 4 05-MAR-2009 0 2008 UL Form CS-CC SAN DIEGO CULTURE AND EDUCATIONAL-ACADEMY 7720 EL CAMINO REAL SUITE K CARLSBAD CA, 92009 FIRE ALARM SYSTEM BILL OF MATERIALS NOTIFIER FIRE WARDEN -50 ADDRESSABLE FACP CSFM# 7165-0028:239 NOTIFIER NP-100 ADDRESSABLE DETECTOR CSFM# 7272-0028:231 NOTIFIER NOT-BGI2LX ADDRESSABLE MANUAL PULL STATION CSFM# 7150-0028:199 WHEELOCK ZNS-MCC- MULTI CANDELA HORN/STROBE CSFM# 7125-0785:142 WHEELOCK ZRS-MCC MULTI CANDELA STROBE ONLY CSFM# 7125-0785:141 DN-71 02:C FireWarden-50 Intelligent Addressable FACP with Built-In Communicator General The NOTIFIER FireWarden-50 (NFW-50) is a Fire Alarm Con- trol Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. This compact, intelli- gent addressable control panel supports up to 50 addressable devices in any combination of detectors or modules. With an extensive list of powerful features, the FireWarden-50 pro- grams just like FireWarden-100 products, yet fits into applica- tions previously served only by conventional panels. The FireWarden-50's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the VFWARDEN- CD Upload/Download utility. In addition, the control panel may be programmed or interrogated off-site via the public switched telephone network. Any personal computer with Windows 95 or greater, and compatible modem with a speed of 14.4 kbps or faster and Upload/Download software kit VFWARDEN-CD, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The power supply and all electronics are contained on a single circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polarity/city box transmitter. (4XTM) The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. Features Listed to UL Standard 864, 9th edition. Auto-program (learn mode) reduces installation time. Reports two devices set to the same address. On-board DACT. Two independently programmable Style Z (Class A) or Style V (Class B) NAC circuits. Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules. Two programmable relays and one fixed trouble relay. Built-in Programmer. Telephone Line Active LEDs. EIA-232 PC interface. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. History file with 500 event capacity. Automatic detector sensitivity testing (NFPA 72 compliant). Automatic device type-code verification. Point trouble identification. Waterfiow selection per module point. NOTIFIER® by Honeywell Alarm verification seLiectior per detector point. Maintenance alert warns when smoke detector dust accu- mulation is excessive. One-person audible or silant walk test with walk-test log and printout. System alarm verification selection per detector point. PAS (Positive Alarm SeqLence) and Pre-signal per point (NFPA 72 compliant). Up to eight ANN-BUS annLnciators. Remote Acknowledge, AI'm Silence, Reset and Drill via addressable modules or remote annunciator. Upload/Download (local or remote) of program and data via integral DACT. SLC COMMUNICATION LCOP Single addressable SLC loop which meets NFPA Style 4, 6 and 7 requirements. 50 addressable device capacity (any combination of addressable detectors and modules). Compatible with NOTIFER FireWarden addressable devices (refer to the Fire Warden SLC Wiring Manual). NOTIFICATION APPLIANCE CIRCUITS (NACS Two independently progranmable output circuits. Circuits can be configured for the fo lowing outputs: - Style V (Class B) - Style Z (Class A) - Door Holder Service (cannot be used for notification appliances) - Aux Power Source (cannot be used for notification appliances) Silence Inhibit and Autosilerce timer options. Continuous, March Time, Temporal or California code for main circuit board NACs witi two-stage capability. Selectable strobe synchronization per NAC. 2.5 A total power for NAGs. NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A. DJ-71O2:C. 12/17/2009—Page 1 of 4 PROGRAMMING AND SOFTWARE Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. m • Two programmable Form-C relay outputs. 20 software zones. Continuous fire protection during online programming at the front panel. NFW-50 Fire Alarm Program Check automatically catches common errors not Control Panel linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in 0 -J N-ANN-80 your office using a Windows®-based software package L) - C/) (order programming kit VFWARDEN-CD separately). Upload/download system programming locally. N-ANN-S/PG NP-100 Printer Gateway User interface Photo Detector N-ANN-ID LED INDICATORS Graphic LED AC Power (green) Module - Fire Alarm (red) NI-100 Supervisory (yellow) Ionization Detector -ANN-LED Trouble (yellow) Alarm Silenced signals (yellow) [N KEYPAD N-ANN-RLY 16 key alpha-numeric pad NH-100 Series Relay Module Acknowledge/Step Heat Detector Alarm Silenced Drill (Manual Evacuate) IN ______ Reset (lamp test) P2R NDM-100 Strobe Product Line Information Dual Monitor Module NFW-50: Combination DACT/Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, chassis - with transformer, backbox with door, plastic bag containing screws, cables, key, etc., manual. (For NFW-50C, refer to ON- NP-11 GOT, NP-Al 00 P2R Strobe 60446.) Photo/Thermal Power Supply NFW-50R: Same as NFW-50, with red backbox and door. FCPS-2456 FCPS-24S8 13 VFWARDEN-CD: Programming software for Windows®- based PC computer (cable not included). NMM-100 lWL P2R DP-51050B: Optional dress panel for NFW-50 (black). Monitor Module Strobe DP-51050: Optional dress panel for the NFW-50R (red). TR-CE-B: Optional trim ring for semi-flush mounting. NZM-100-6, NMM-100-10 BB-XP: Optional cabinet for one or two modules. Multiple-Circuit Optional cabinet for up to six modules mounted on NZM100 2-Wire Detector Interface Module CHS-6 chassis. Monitor Module Battery backbox, holds up to two 25 AH batteries and CHG-75. NFS-LBB: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-25 N[)-1Ou,l[)-I00R, DNA cabinet. Duct Detector CHG-75: Battery charger for lead-acid batteries with a rating NFW-50 of 25 to 75 AH. CHG-120: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional NFS- ______ LBB for mounting. NOT-BG12LX CONTROL PANEL NOTE: CHG-120 or CHG-75 required for batteries larger than Addressable I8AH. Manual Pull Station BAT Series: Batteries, see data sheet DN-6933. Page 2 of 4— DN-7102:C • 12/17/2009 PRT/PK-CABLE: Cable printer/personal computer interface cable. PRN-6: UL listed compatible event printer. Uses tractor-fed paper. IPDACT, IPDACT-2/2UD Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet dn-60408 for more information.) IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure. IPSPLT: V-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. AC-TRMBLK: AC Terminal Block mounts to a metal bracket, in turn, mounts to the FACP chassis. Use AC-TRMBLK when wire nuts are not allowed for AC connections to the trans- former. OPTIONAL MODULES 4XTM Reverse Polarity Transmitter Module: Provides a supervised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trou- ble LED. COMPATIBLE ANNUNCIATORS N-ANN-80(-W):Remote LCD annunciator mimics the informa- tion displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is black; order -W for white; see DN-71 14.) N-ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DN-71 05.) N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DN-60242.) N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242) N-ANN-RLY: Relay Module provides 10 programmable Form- C relays. Can be mounted inside the cabinet. (See DN-71 07.) N-ANN-SIPG: Serial/Parallel Printer Printer Gateway module provides a connection for a serial or parallel printer. (See DN- 7103.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI-100: Addressable low-profile ionization smoke detector. NP-100: Addressable low-profile photoelectric smoke detector. NP-lOOT: Addressable low-profile photoelectric smoke detec- tor with thermal sensor. NH-100: Fast-response, low-profile heat detector. NH-100H: Fast-response, low-profile heat detector that acti- vates at 190°F/88°C. NP-Al 00: Addressable low-profile multi-sensor detector. ND-100: Photoelectric low-flow duct smoke detector. ND-100R: Photoelectric low-flow duct smoke detector with relay option. DNA: lnnovair Flex low-flow non-relay duct-detector housing. (Order NP-100 separately.) DNRW: Innovair Flex low-flow non-relay duct-detector hous- ing, with NEMA-4 rating. Watertight. (Order NP-100 sepa- rately.) NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0' (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only IDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NZM-100A: Similar to NMM-100A. Addressable Monitor Mod- ule for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limita- tion. NZM-100-6: Six-zone interface module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. NMM-100-10: Ten-input monitor module. Mount one or two modules in a BB-2 cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-25 cabinet. NC-100: Addressable Control Module for one Style VIZ (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NOT-BG12LX: Addressable manual pull station with interface module mounted inside. N100-ISO: Fault Isolator Module. SMB500: Used to mount all modules except the NMM-1 OOP. NOTE: For more information on Compatible Addressable Devices for use with the Fire Warden-50, see the following data sheets (document numbers): NIOO-lSO (DN-6994), NP-100/NP- lOOT (DN-6995), NI-IOU (DN-6996), NH- 100/NH- IOOR (DN-6997), ND- 100/ND-100R (DN-7006), NP-A100 (DN-6998), NMM- 100/NMM- IOOP/NDM-100/NZM-100 (DN-6999), NC-100 (DN-7000), NC- 100R (DN-60383), NMM- 100-10 (DN-6990), and NOT-BG I2LX (DN-7001). ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.9K): 47k ohm supervises the NMM-100-10, NDM-100, NMM-100P, and NC-100 module circuits. 3.9k ohm End-of-Line Resistor assembly supervises the NZM-100-G module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Refer to the panel manual for wiring details. DN-71 02:C • 12/17/2009 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits.......................................1 Addressable device capacity............................................50 Programmable software zones.........................................20 Annunciators ......................................................................8 Electrical Specifications AC Power: FireWarden-50: 120 VAC, 60 Hz, 3.0 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Capacity: 7-18 AH (FireWarden-50 cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides connections for two NACs, Style V (Class B) or. Style Z (Class A). Special Application power. Power-limited, supervised cir- cuitry. Maximum signaling current per circuit: 2.5 A. End-of- Line Resistor: 4.7 kohm, ½ watt (P/N 71252 UL listed) for Style V (Class B) NAC. Refer to the NOTIFIER Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, nonpower-limited, nonsupervised. Cabinet Specifications Door: 19.26 (48.92 cm.) high x 16.82 (42.73 cm.) wide x 0.72 (1.82 cm.) deep. Backbox: 19.00 (48.26 cm.) high x 16.65 (42.29 cm.) wide x 5.25 (13.34 cm.) deep. Trim Ring (TA-CE): 22.00' (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 31F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 270C/60 - 80°F. NFPA Standards The FireWarden-50 complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Network) Agency Listings and Approvals The listings and approvals below apply to the basic FireWar- den-50 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL: S635 FM approved CSFM: 7165-0028:239 MEA: 442-06-E Vol. 2 NOTE: See DN-60446 to ULC-listed model. NOTIFIER®, FlreWarden®, and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I Iso ooi We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. _ i _______________ I I MRINFERINI I MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4- DN-7102:C • 12/17/2009 Power Supply Calculations Table 7.3 contains columns for calculating current draws. For each column, calculate the current and enter the total (in amperes) in the bottom row. When finished, copy the totals from Calculation Column 2 and Calculation Column 3 to Table 7.4 on page 182. Table 7.3 System Current Draw Calculations Calculation Column I Primary, Non-Fire Alarm Current Device Type (amps) Calculation Column 2 Primary, Fire Alarm Current (amps) Calculation Column 3 Secondary, Non-Fire Alarm Current (amps) Qty Xlcurrent draw] Total Qty X [current draw] = Total Qty X[current draw]= Total Main Circuit Board I X[0.120] 0.120 1 X[0.200] 0.200 1 X[0.120] 0.120 4XTM [ ] X[0.005}= [ I X[0.011]'= [ I X[0.005]= 4-wire Detector Heads [ I X[]2= [ ] X[ 1= [ ] X[ ] Power Supervision ] X[O.025}= Relays _____________________________________________ [ ] X[O.025]= [ I X[O.0251= NI-lOP J X[0.00030j= maximum alarm draw for all devices 0.400 -I I X[0.00030] NP-lop J X[0.000301= - l I X[0.00030]= NP-lOOT I - X[0.00030]= - X[0.00030]= NH-lop - X[0.00030] - - X[0.00030]= NH-100R [ X[0.00030]= - - X[o.00030j= ND-lop J X[0.00030]= X[0.00030]= ND-100K -J X[0.00030]= - X0.00030] NMM-100 - X[0.00040]= x[0.00040= NDM-100 -I X[O.00075j= - -1 X[0.00075]= NMM-1001? J XO.000375= - -I XO.0003751= NZM-100 -J X[O.00027]= -t I X[O.00027]= NOT-BG12LX -J X[o.000231= 7[0.00023]= NC-lop I -I X[O.00039]= . - ir x[o.00039]= NC-1001K - Xo.00027J= - - X[P.00027]= N-lOOlSO [J X[o.00045]= I X[0.000401= 11 XO.0370]= [I X[0.0400]= 1r X[0.0150] - N-ANN-I/0 - X[O.0350] [ ] X[O.2000] - 1f X[o.0350]= N-ANN-RLY -1 X[0.0150]= J X[0.0750] - -I X[O.01501= N-ANN-(R)LED I -3 X[O.0280]= [ I X[0.0680]= - - X[O.0280]= N-ANN-S/PU f -3 X[O.0450]= NAC#14 NAC#2 Sum each columns for totals Primary Non-Alarm [ ] X[O.0450= [ I X[ 1= Primary Alarm XE 1= - T1 X[0.0450]= Secondary Non-Alarm = Table Footnote If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. Refer to the Device Compatibility Document for standby current. Must use compatible listed Power Supervision Relay. Current limitation of Terminal TB! circuits is 2.5 amps total max. Total current draw listed above cannot exceed 2.7 amps. FireWarden-50 & FireWarden-50C PN 52911:C 05/30/08 181 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 911 LISTING No. 7165-0028:239 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Notifier, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Lawrence T. Flood (203) 484-6302 FAX (203) 484-7309 DESIGN: Model FireWarden-50 addressable fire alarm control unit. Unit consists of one communication loop, two bell circuits, and three relay contact outputs for alarm, trouble and supervisory. Local, auxiliary, remote station, central station and proprietary (protected premise),automatic, manual, water flow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 3.0 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 91h Edition Standard. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. XLF: 7165-0075:210 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 15, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division dn-6995:al • Al -320 0 NOTIFIER® for the FireWarden Series by Honeywell Addressable GENERAL NP-100, NP-100T Addressable Photoelectric Detectors The NP-100 and NP-100T addressable, low-profile plug-in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWar- den Series (FireWarden-100-2 and FireWarden-50) Address- able Fire Alarm Control Panels (FACPs). The NP-100T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annun- ciator capability is available as an optional accessory (PIN RA400Z). FEATURES SLC loop: Two-wire loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade entry of address: 01 - 99 with FireWarden- 100-2, and 01 —50 with FireWarden-50. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0° (10.16 cm) octagonal box, or 4.0 (10.16 cm) square electrical box (using a plaster ring - included). Other system features: Fully coated circuit boards and superior RF/transient pro- tection. 94-VO plastic flammability rating. Low standby current. Options: Remote LED output connection (P/N RA400Z). NP-I 00 wit, B350LP base N-10OT with B35O_P base APPLICATIONS Use photoelectric detectors in life saIety applications to pro- vide a broad range of fireiensing capability, especially where smoldering fl-es are anticipated. lolization detectors are often better than )hotoelectric detectors at sensing fast, flaming fires. CONSTRUCTION These detectors are constructed of off-white LEXAN®. NP-101J(T) pug-in, low-pr.--file smcke detectors are designed to commercial standards and offer an attractive appearance. INSTALLATION NP-100(T) plug-in detectors use a deachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1 5 inches (3.81 cm) deep. Suitable boxes ncludé: 4.0° (10.16 cm) square box with plaster ring. 4.0° (10.16 cm) octagonal box. 3.5° (8.89 cm) octagona. box. Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-fine resistors are not required. Wiring 7-taps" or bran.hes are oermitted for Syle 4 (Cass B) wiring. dn-E995:al • 05/08/09 - Page 1 of 2 OPERATION Each NP-100(T) uses one of 99 possible addresses on the FireWarden-100-2 and one of 50 possible addresses on the FireWarden-50 Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The NP-100(T) addressable photoelectric sensor's unique uni- polar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 rn/sec.) without sending an alarm level signal. Because of its unipolar chamber, the NP-100(T) is approximately two times more responsive than most photo- electric sensors. This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have its sensitivity tested (required per NFPA 72, Chapter 10 on Inspection, Testing and Maintenance) when installed/connected to a FireWarden-100-2 or FireWar- den-50 addressable fire alarm control panel. The results of the sensitivity test can be printed off the FireWarden-100-2 or Fire- Warden-50 for record keeping. SPECIFICATIONS Voltage range: 15-32 VDC (peak). Standby current: 300 .iA@ 24 VDC. 1ED current: 6.5 mA @ 24 VDC (latched "ON"). Air velocity: 4,000 ft/mm. (20 rn/sec.) maximum. Diameter: 6.1' (15.5 cm) installed in B71OLP base. Height: 2.1° (5.33 cm) installed in B71OLP base. Weight: 3.6 oz. (102 g). Operating temperature range: for NP-100: 0°C to 49°C (32°F to 120°F); for NP-100T.- 0°C to 38°C (32°F to 100°F). Temperature: 0°C - 49°C (32°F - 120°F). Relative humidity: 10% - 93%, non-condensing. LISTINGS Listings and approvals below apply to the NP-100 and NP- 100T detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed, file S1115. CSFM approved: file 7270-0028:231. MEA approved: file 243-02-E Vol. Il. Maryland State Fire Marshal: permit 2173. FM approved. PRODUCT LINE INFORMATION NP-100: Adressable photoelectric detector; B71OLP base included. NP-100T: Same as NP-100 but with thermal element; B71OLP base included. B71OLP: Plug-in detector base. Dimensions: 6.1" (15.5 cm). Mounting: 4.0° (10.16 cm) square box with or without plaster ring, 4.0° (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224RB: Plug-in System Sensor relay detector base. Diame- ter: 6.2° (15.75 cm). Mounting: 4.0° (10.16 cm) square box with or without plaster ring, 4.0° (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a mini- mum depth of 1.5° (3.81 cm). B224B1: Plug-in System Sensor isolator detector base. Maxi- mum 25 devices between isolator bases (see DN-6994). Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0° (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B501 BH-2: Plug-in System Sensor sounder detector base. Diameter. 6.0" (15.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring. Mounting box has a minimum depth of 1.5" (3.81 cm). B501BHT-2: Plug-in System Sensor temporal tone sounder detector base. ACCESSORIES: RA400Z: Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 and B71OLP bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with B501 base only. RMK400: Recessed mounting kit. For use with B501 base only. M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR213: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR213. Comes in three 5-foot (1.524 m) sections. T55-127-010:Detector removal tool without pole. BCK-200B: Black detector covers, box of 10. WCK-200B: White detector covers, box of 10. NOTIFIER® is a registered trademark of Honeywell International Inc. Bayblend® is a registered trademark of Bayer Corporation. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 000i We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. UGlNEEHlNE & MNDFAC11II1IN All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2012- dn-6995:al • 05/08/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:231 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Notifier, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models NP-100 and NP-100T photoelectric type smoke detectors. Model NP-100T has a 1350F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units. All units are suitable for installation inside air duct with a maximum air velocity of 4000 fpm. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0075:194 11-03-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 15, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division NOT-BGI 2LX(A) Addressable Manual Pull Station For FireWarden Series Panels General The Notifier NOT-BG12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels. Because the NOT-BG12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-i 0 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: pA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Installation The NOT-BG12LX will mount semi-flush into a single-gang, double-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NOT-BG12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. DN-7001:C • A1-380 NOTIFI ER® by Honeywell The NOT-BGI2LX Addressable Manual Pull Station The BG127F is usLafly needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the dowrlactivatedil position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a por-ion of the handle protrudes from the oottom of the station. To teset the station, simply unlock the station with the key and pul tie door open. This action resets the handle; clos- ing the doot autorna:ically resets the switch. Each manLal statioi, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 —99 on 'JFW2-100/NFW2-100C, 1 —50 for NW-50/NFW- 50C). Architectural/Engineering Specifications Manual FirE Alarm Stations shall be non-coded with a key- operated reset lock r order that they may be tested, and so designed thai after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically conditicn itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored p.)Iycarbonate material with clearly visible operat- ing instructbns provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger Stations shall be suitable for surface mounting or matching backbox SB-i 0 or SB-I/O; or semi-flush mounting on a stadard single-gang, double-gang, or 4° (10.16 cm) scuare electrical box, and shall be installed within DN-7001:C.09/18/2009—Page 1 of 2 the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual-action addressable pull station. Includes key locking feature. NOT-BG12LXA: Canadian Dual-action addressable pull sta- tion. Includes key locking feature. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S692 (listed for Canadian and non-Canadian applications) MEA: 67-02-E Vol. IV CSFM: 7150-0028:199 FM Approved Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Notifier% is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. S O This document is not intended to be used for installation purposes. I 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. R MANUFACTIMNS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-7001 :C • 09/18/2009 NOTIFIER by Honeywell NOT-BG12LX Addressable Pull Station Patented, U.S. Patent No. Des. 428,351; 6,380,846; Other Patents Pending Document 52135 156-3515-000 Description The NOT-BG12LX Addressable pull station is a non-coded, dual-action manual pull station with a key-lock reset feature. It provides Notifier's FireWarden- 100, a 198-point addressable fire alarm control panel, with one addressable alarm initiating input. The addressable module is housed inside the pull station and may be accessed by opening the door without initiat- ing an alarm.. The NOT-BG12LX meets the ADAAG controls and operating mechanisms guidelines (section 4.1.3 [13]), and the ADA requirement for a 5 lb. maximum pull force to activate the pull station. Operating instructions are molded into the pull station handle along with Braille text. Molded Terminal numbers are also present. Ratings Normal Operating Voltage: 24 VDC. 'Average Operating Current (LED Flash):300 ,uA. Temperature Range: 32° F - 120° F (00 C - 490 Q. Relative Humidity Range: 10% - 93% non-condensing. Installation The NOT-BG12LX Addressable pull station can be surface mounted to an SB- 10 or SB-I/O surface backbox or semi-flush mounted on a standard single-gang, double-gang or 4" (10.16 cm) square electrical box. The optional BG-TR trim ring can be used if the NOT-BG12LX is to be semi-flush mounted. Operation To activate the dual-action pull station, push in and pull down on the handle. The word 'ACTIVATED' appears after the handle is pulled down. This will remain until the pull sta- tion is reset. The pull station includes one Single Pole, Single Throw (SPST) Normally Open (NIO) switch which closes upon activation of the pull station. Resetting the Pull Station Insert the key into the lock and rotate 1/4 turn counterclockwise. Open the door until the handle returns to normal. Close and lock the door. NOTE: Closing the door automatically resets the switch to the 'Normal' position. Open- ing the door will not activate or deactivate the alarm switch. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:199 Page 1 of 1 CATEGORY: Fire Alarm Boxes LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Vladimir.kireyev@honeywell.com DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG- 12-LO, NBG-12LOB, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-12LWP, NBG- 12L, NBG-12LX, NBG-12LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-12LPSP, NBG- 12SP, NOT-BG12LX, and NBG-12LXSP fire alarm pull boxes. All units except Model NBG- 12S are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-12LW, NBG-12W, NBG-I2LWP, NBG-12LAO, NBG-12L0, NBG- 12LAOB and NBG-I2LOB are intended for outdoor use when installed with Models WBB, SB- I/O, orWP-10 back box. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. Updated 08-11-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: AUGUST 11, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division - Features an easy snap on base designed to simplify the installation and testing of strobes, horns and horn strobes. Available features and options: Color: Red or white Mounting: Wall or ceiling EZ mount SNAP design Universal mounting plate - single plate for wall and ceiling mount in- stallations Disposable cover to protect base plate Strobes produce 1 flash per sec- ond over the Regulated Voltage Range 1-2 09/06 Strobes Z If Wall Mount Strobes UL Max. Current 15cd 30cd 75cd hOed ZRS-MCW-FR Red 4085 24 VDC 0.060 0.092' 0.165 0.220 ZRS-MCW-FW White 0302 ZRS-MCWH-FR Red 5242 ZRS-MCWH-FW White 0303 UL Max. Current 135cd 185cd Ceiling Mount Strobes 24 VDC 0.300 0.420 ZRS-MCC-FW White 0309 ZRS-MCC-FR Red 0308 UL Max. Current 15cd 30cd 75cd 95cd ZRS-MCCH-FW White 0314 24 VDC 0.065 0.105\ 0.189 0.249 ZRS-MCCH-FR Red 5240 UL Max. Current 115cd 177cd 24 VDC 0.300 0.420 Horns and Horn Strobes Wall or Ceiling Mount Horn ZNH-R Red 0300 ZNH-W White 0301 Wall Mount Horn Strobe ZNS-MCW-FR Red 0304 ZNS-MCW-FW White 0305 ZNS-MCWH-FR Red 0306 ZNS-MCWH-FW White 0307 Ceiling Mount Horn Strobe ZNS-MCC-FW White 0311 ZNS-MCC-FR Red 0310 ZNS-MCCH-FW White 0313 ZNS-MCCH-FR Red 0312 UL Max. Current 15ed 30cd 75cd 110cd High (95) dBA 24 VDC 0.074 0.107 0.184 0.244 Low (90) dBA 24 VDC 0.066 0.101 0.177 0.232 UL Max. Current 1 5c 30cd 75cdL 95cd fl High (95) dBA 24 VDC 0.082 "0. 124 0.209- 0.275 - Low(90)dBA 24 VDC 0.071 0.114 0.201 0.261 UL Max. Current UL Max. Current Audible 11 5c 177cd 24 VDC 12 VDC High (95) dBA 0.350 0.477 High (95) dBA 0.044 0.021 Low (90) dBA 0.306 0.429 Low (90) dBA 0.018 0.012 (800) 631-2148 www.cooperwheelock.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:142 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 deborah.piserchia@cooperwheelock.com DESIGN: Models NH-12/24, NH-12/24R, and ZNH horns and Models NS-1215W, NS-121575W, NS-2415W, NS-241575W, NS-2430W, NS-2475W and NS-24110W; NS4-1215W, NS4- 121575W, NS4-2415W, NS4-241575W, NS4-2430W, NS4-2475W and NS4-241 low, NS-24MCW, NS4-24MCw, NS-24MCC, NS-24MCCH, ZNS-MCW, ZNS-MCC, ZNS- MCWH and ZNS-MCCH horn strobes. Model number may be followed by any two- alpha/numeric characters indicating lens, lettering and color. Units are synchronized or non-synchronized strobes. Models NH-12/24R, NS-24MCC, NS-24MCCH, ZNS-MCC and ZNS-MCCH are ceiling mount only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical-Strobe Horn: 8-17.5 VDC/FWR and 16-33 VDC/FWR Horn: 8-17.5 VDC/FWR and 16-33 VDC/FWR Candela: 15=15cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110=110cd (Wall) NS-24MCW, NS4-24MCw, ZNS-MCW: Selectable 15cd, 30cd, 75cd, 110cd NS-24MCC, ZNS-MCC: Selectable 15cd, 30cd, 75cd, 95cd NS-24MCCH, ZNS-MCCH: Selectable 115cd, 177cd ZNS-MCWH: Selectable I 35cd, 185cd Flash rate: 60 Flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. All units are for wall mount except for *Models NH-12/24R, NS-24MCC, NS-24MCCH, ZNS-MCC and ZNS-MCCH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as audible and audible/visual signaling devices for use with separately listed electrically compatible fire alarm control units. Models with strobe lights are suitable for the hearing impaired. For indoor use only except for model NH-12/24 horn. All synchronization strobes shall be used with Models SM-12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132). Refer to manufacturer's installation manual for details. NOTE: These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *Corrected 07-25-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS- 24MCCHR, RSSP-24MCCH, *ZRS..MCC *ZRSMCW *ZRS..MCCH and *ZRS.MCWH Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 =16-33VDC/FWR Candela 15=5cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110=110cd (Wall) RSS-24MCW, RSSP-24MCW, *ZRSMCW: Selectable 15cd, 30cd, 75cd orll0cd RSS-24MCC, RSS-24MCCR, RSSP-24MCC, *ZRS.MCC: Selectable 15cd, 30cd, 75cd and 95cd RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, *ZRS.MCWH: Selectable 135cd, 185cd RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *ZRSMCCH: Selectable 115cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. *Rev. 12-13-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division - FAo9oo FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-31 FIRE ALARM SYSTEM RECORD OF COMPLETION Name of protected property: San Diego Culture & Fduieation Academy Address: - 7720 Fl Camino Real Suite K. Carlsbad, CA 92009 Representative of protected property (name/phone): Authority having jurisdiction: Carlsbad Fire Department - Address/telephone number: 760-602-4660 Organization name/phone Representative name/phone Installer JJJ Enterorises Supplier Notifier Service organization JJJ Enterprises Location of record (as-built) drawings: 7720 El Camino Real Suite K, Carlsbad, CA 92009 - Location of operation and maintenance manuals: 7720 El Camino Real Suite K, Carlsbad, CA 92009 Location of test reports: 7720 El Camino Real Suite K, Carlsbad, CA 92009 A contract for test and inspection in accordance with NFPA standard(s) Contract No(s): N/A Effective date: Expiration date: System Software Operating system (executive) software revision level(s): Site-specific software revision date: Revision completed by: (name) (tern) 1. Type(s) of System or Service Z NFPA 72, Chapter 6— Local If alarm is transmitted to location(s) off premises, list where received: El NFPA 72, Chapter 8— Remote Station Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: - - - If alarms are retransmitted to public lire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: 0 NFPA 72, Chapter 8— Proprietary Telephone numbers of the organization receiving alarm: Alarm: Supervisory: - Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: - El NFPA 72, Chapter 8— Central Station Prime contractor: Central station location: FIGURE 4.5.2.1 Record of Completion. (NFPA 72, 1 of 4) 2002 Edition 72-32 NATIONAL FIRE ALARM CODE Means of transmission of signals from the protected premises to the central station: 0 McCulloh 0 Multiplex El One-way radio El Digital alarm communicator El Two-way radio 0 Others Means of transmission of alarms to the public fire service communications center: System location: 0 NFPA 72, Chapter 9—AuxilIary Indicate type of connection: 0 Local energy 0 Shunt 0 Parallel telephone Location of telephone number for receipt of signals: 2. Record of System Installation (Fill out after installation is complete and wiring is checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by Larry Johnson on 1/12/2010 , includes the devices shown in 5 and 6, and has been in service since 1/12/2010 NFPA 72, Chapters 0 6J J G 0 Q 8 9 6) 11 (circle all that apply) Z NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions 0 Other (specify): Signed: Date: 1/12/2010 Organization: JJJ irprcses 3. Record of System Operation Documentation in accordance with Inspection Testing Form, Figure 10.6.2.3, is attached All operational features and functions of this system were tested by Larry Johnson date 1/12/2010 and found to be operating properly in accordance with the requirements of: Z NFPA 72, Chapters ([) () ( () (J () 8 9 (j) 11 (circle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions - El Other (specify): Signed: Date: 1/12/2010 Organization: JJJ Enterfes U Signaling Line Circuits Quantity and class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity: 1 Style: 4 Class: b I (NFPA 72,20f4) j FIGURE 4.5.2.1 Continued 2002Edition FUNDAMENTALS OF FIRE ALARM 72-33 5. Alarm-Initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 6.5): Quantity: None Style: Class: MANUAL Manual stations Noncoded .2 Transmitters Combination manual fire alarm and guard's tour coded stations AUTOMATIC Coverage: Complete Selective _________ Coded _________ Addressable Partial Nonrequired Smoke detectors 10 Ion Photo 10 Addressable 10 Duct detectors 0 Ion Photo Addressable Heat detectors 0 FT RR FT/RR RC Addressable Sprinkler waterfiow indicators: Transmitters 0 Noncoded Coded Addressable 0 The alarm verification feature is disabled or enabled , changed from seconds to seconds. Other (list): 6. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR [J Coded stations [1 Noncoded stations 0 Compulsory guard's tour system comprised of transmitter stations and intermediate stations Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guard's Tour SPRINKLER SYSTEM Check if provided El Valve supervisory switches =Building temperature points D Site water temperature points 0 Site water supply level points Electric fire pump: a_Fire pump power (0 El Fire pump running 0 Phase reversal Engine-driven fire pump: El Selector in auto position 0 Engine or control panel trouble (i) 0 Fire pump running ENGINE-DRIVEN GENERATOR: 0 Selector in auto position El Control panel trouble =Transfer switches Engine running Other supervisory function(s) (specify): (NFPA 72, 3 of 4) FIGURE 4.5.2.1 Continued 2002Edition 72-34 NATIONAL FIRE ALARM CODE Annunciator(s) Number: 0 Type: Location: 8. Alarm Notification Appliances and Circuits NFPA 72, Chapter 6— Emergency Voice/Alarm Service Quantity of voice/alarm channels: 0 Single: ________________ Multiple: Quantity of speakers installed: 0 Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: 0 Quantity and the class of notification appliance circuits connected to system (see NFPA 72, Table 6.7): Quantity: I Style: Y Class: B Types and quantities of notification appliances installed Bells 0 With Visible Speakers 0 With Visible Horns 5 With Visible 5 Chimes 0 With Visible Other: 0 With Visible (I) Visible appliances without audible: 3 9. System Power Supplies Fire Alarm Control Panel: Nominal voltage: 120 VAC Current rating: 3.0 Amps Overcurrent protection: Type: Breaker Current rating: 20 amps Location: Back wall Electric Panel 1 Circuit #29 Secondary (standby): Storage battery: 12v Amp-hour rating: 7.0 Calculated capacity to drive system, in hours: 24 Engine-driven generator dedicated to fire alarm system: nla Location of fuel storage: Emergency system used as backup to primary power supply: Emergency system described in NFPA 70, Article 700: nla 10. Comments Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): N/A System deviations from the referenced NFPA standard(s) are: ..None i6djTor alarm service company (title) (date) (signed) for central station (title) (date) Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): representative of the authority having jurisdiction (title) (NFPA 72, 4 of 4) FIGURE 4.5.2.1 Continued 2002Edition