Loading...
HomeMy WebLinkAbout7662 EL CAMINO REAL; ; FS0700229/26/24, 8:13 AM FS070022 Permit Data City of Carlsbad Fixed Systems Permit 7662 EL CAM INO Job Address: REAL Permit Type: FIXSYS Parcel No: 2165800700 Lot #: 0 Reference No.: Permit No: FS070022 Status: ISSUED Applied 12/10/2007 Approved: 12/11/2007 Issued: 12/11/2007 PC #: Inspector: Project Title: RUDY'S TACOS T.I. HOOD & DUCT PLAN CHECK & INSPECTION Applicant: INTERSTATE FIRE PROTECTION 36140 JANA LANE WILDOMAR, CA 951-764-2921 Owner: GRANT TUCKER PROPERTIES P 0 BOX 7974 NEWPORT BEACH CA IFees IJI 1Total IBalance s 4J [130 0 130 0 about:blank 1/1 SECTION 3 FSO~-002~- DESIGN MANUAL PIN 12385 Rev. A !A kA II IP1 KP RESTAURANT FIRE SUPPRESSION SYSTEM Tested and Listed by Underwriters Laboratories, Inc. to UL Standard 300 EX 4658 Tested and Listed by Underwriters Laboratories of Canada To ULCIORD 1254.6-1995 October 2003 TOctober2003 Section .3 Design Page 3-1 I Amerex KP Wet Chemical System (EX 4658) DUCT PROTECTION DUCT PROTECTION LIMITATIONS SINGLE NOZZLE (PIN 16416) The Amerex duct nozzle (P/N 16416) is listed to protect restaurant cooking ducts of unlimited length up to 50 perimeter inches (127 cm) or 16 diameter inches (40.6 cm) using one nozzle. The nozzle has one flow point and must be centered within the duct, placed 2 - 8 inches (5.08 - 20.32 cm) into the duct opening and aimed at the center of the cross section of the duct. NOTE: In no case shall the diagonal dimension of the duct exceed 18.8 inches without additional duct nozzles. OF VERTICAL DUCT 9 - - - OF HORIZONTAL DUCT /M P DINT VERTICAL / HORIZONTAL DUCT TRANSITIONS Special Note: For ducts with vertical/horizontal transitions reference the diagram above with respect to nozzle aim. TRANSITION LIMITATIONS - SINGLE NOZZLE (PIN 16416) A transition is a section found on some exhaust systems between the hood and the duct. One Amerex duct nozzle (P/N 16416) will protect a transition at the point where the transition is 50 perimeter inches (127 cm) or less or a diameter of 16 inches (40.6 cm) or less. The nozzle has one flow point and must be placed in the center of the opening at the point where the perimeter inches are 50 (127 cm) or less or where the diameter inches are 16 (40.6 cm) or less and aimed at the center of the cross section on the duct. Additional duct protection is not required when using this method. October 2003. Section 3. Design Page -Arnerex KP Wet.Cêmil System (EX4S8) DUCT PROTECTION LIMITATIONS - TWO NOZZLES (2 x P/N 16416) Two Amerex duct nozzles (P/N 16416) will protect ducts with 51 inches to 82 inches (129.5 - 208.3 cm) or a maximum d inches (66 cm). To correctly position the nozzles a rectangulE be divided along its longest side into four equal distances. should be divided along a centerline into four equal distance should be placed at one quarter of the duct's width (or diame nozzles on the centerline, paced 2-8-inches (5.08 - 20.3 cm) opening and aimed at the center of the cross section of thE nozzle has one flow point. NOTE: In no case can the diagonal dimension of each module exceed 18.8 inches (46 cm). DUCT PROTECTION LIMITATIONS 100 IN. PERIMETER TWO - 11/2 FLOW POINT NOZZLES (PIN 11983) The Amerex solid fuel appliance/duct nozzle (P/N 11983) is listed to protect a restaurant cooking exhaust duct of unlimited length and up to 100 perimeter inches (254 cm) or 32 inch diameter (81.2 cm) using two nozzles. The nozzles total three flow points and to properly position the nozzles, a rectangular duct should be divided along its longest side into four equal distances. A circular duct should be divided along its center line into four equal distances. The nozzles are to be placed at one quarter and three quarters position of the duct width (or diameter) with both nozzles on the center line, placed 2 - 8 inches (5.08 - 20.3 cm) into the duct opening and aimed straight up in a vertically run duct. NOTE: In no case can the diagonal dimension of the duct exceed 37.2 inches (94.4 cm) without adding additional duct nozzles. NOTE: The use of one duct nozzle P/N 11983 is permitted for duct 50 perimeter inches or less in the same manner as duct nozzle 16416. 32' MAX October 2003 Section 3 Design Page 3-3 Amerex KP We Chemical System (EX 4658) DUCT PROTECTION LIMITATIONS 150 IN. PERIMETER THREE 11/2 FLOW POINT NOZZLES (3 x P/N 11983) The Amerex solid fuel appliance/duct nozzle (P/N 11983) is listed to protect restaurant cooking exhaust ducts of unlimited length and up to 150 perimeter inches (381 cm) or 48 diameter inches (122 cm) using three nozzles. The nozzles total four and one-half flow points and to properly position the nozzles, a rectangular duct should be divided along its longest side into six equal distances. A circular duct should be divided along its center line into six equal distances. The nozzles are to be placed at one sixth, one half and five sixths positions of the duct width (or diameter) on the center line, placed 2-8 inches (5.08 - 20.3 cm) into the duct opening and aimed straight up for vertically run duct. NOTE: In no case can the diagonal dimension 55.9 inches (142 cm) without addin nozzles. TRANSITION LIMITATIONS -TWO NOZZLE (P/N 11983) A transition is a section of some exhaust systems between the hood and the duct. Two Amerex solid fuel appliance/duct nozzles (P/N 11983) will protect a transition at the point where the transition is 100 perimeter inches (254 cm) or less or a diameter of 32 inches (94.4 cm) or less. The nozzles total three flow points and to properly position the nozzles, a rectangular duct should be divided along its longest side into four equal distances. A circular duct should be divided along its center line into four equal distances. The nozzles are to be placed at one quarter and three quarters position of the duct width (or diameter) with both nozzles on the center line, placed 2 - 8 inches (5.08 - 20.3 cm) into the duct opening and aimed straight up in a vertically run duct. Additional duct protection is not required when using this method. NOTE: In no case can the diagonal dimension of the duct exceed 37.2 inches (94.4 cm) without adding additional duct nozzles. (REFER TO PAGE 3-2 FOR PICTORIAL REPRESENTATION) October 2003 Section 3 Design Page 3.4 Aeèx KP Wet ChCthicl System (EX 468). NOZZLE LOCATION AND AIMING FOR HORIZONTALLY RUN DUCTS PROTECTED BY DUCT NOZZLE 11983 The nozzles are to be located on the centerline of the vertically run duct, 2-8 inches (5.08-20.3cm) into the OF VERTICAL DUCT duct. The aiming point is to be a point 3 (7.6cm) inches above the base of the horizontally run duct and in the same vertical plane of the nozzle. See illustration. OF HORIZONTAL DUCT [DUCT AIM POINT NOZZLE VERTICAL / HORIZONTAL DUCT TRANSITIONS DUCT PROTECTION LIMITATIONS - MULTIPLE NOZZLES (P/N 16416) Protecting ducts larger than 100 perimeter inches (254 cm) utilizing the single flow point nozzle (P/N 16416) the perimeter is divided by 50 (126.9 cm). The resulting number must be rounded up to the next whole number. This equals the minimum number of duct nozzles that must be used. The cross sectional area of the duct is then divided into the same number of equally sized modules. The duct nozzle is then located in the center of each module. Note: In no case can the diagonal dimension of each module exceed 18.8 inches (46 cm) without adding additional duct nozzles. 2A + 213 PERIMETER OR (A + B) 2 = PERIMETER Single Bank Protection - 1/3 FILTER HEIGHT - T FROM ThETOP OF THE FILTER, ON CENTER BETWEEN SIDEWALL AND FILTER AT. N. NOZZLE TO BE LOCATED 0 -4" FROM END WALL, CENTERED ON THE FILTER October 2003 : . .':: . SeCton 3 Désigr ... Page 3 5 Ame.ëx KP Wt.Chèmibal Stern (Ex 4658) PLENUM PROTECTION PLENUM PROTECTION LIMITATIONS - SINGLE FLOW POINT NOZZLE (P/N 11982) The Amerex appliance, plenum nozzle (P/N 11982) is capable of protecting plenums up to 10 feet (3.048m) long with either a single inclined filter bank or a 'V" bank filter arrangement. The filter height cannot exceed 24 inches (60.96 cm). Each plenum nozzle uses one flow point. The nozzle must be positioned 4 inches (10.16) maximum from the wall, aimed horizontally and positioned down 1/3 the filter height from the top of the filter. NV,. Bank Protection 1/3 FILTER HEIGHT DOWN FROM THE - TOP OFThERLTER. CENTERED INThE V" BANK NOZZLETO BE a 4 LL, ThE "V"BANK PLENUM PROTECTION - MULTIPLE NOZZLES Plenums exceeding 10 feet (3.048 m) in length may be protected by using multiple plenum nozzles. Each nozzle must be protecting an area of no more than 10 feet in length. Nozzles may be positioned facing each other or facing the same direction as long as the entire plenum area is being covered. Nozzles may not face in opposite directions from a common tee. FULL VAT FRYER WITH DRAINBOARD NOZZLE NO APART 36' 41 I 17% J " \ 4?4o I ' 19W AIMING POINT October 2008 •• • ••. $ection3 Design 1; Page 3— 6 Amerex KP Wet Chemical System (EX 4658) FRYER PROTECTION (FULL VAT) TWO FLOW POINT NOZZLE (P/N 13729) MAXIMUM AREA: 191/2 in. (50 cm) x 25-3/8 in. (65 cm) including drainboard interface area 191/2 in. (50 cm) x 19 in. (48 cm) not including drainboard interface area The Amerex fryer nozzle (PIN 13729) uses two flow points and will protect a full vat fryer. If the fryer does not include a drainboard, the maximum fryer dimensions for single nozzle coverage are 19" x 191,4" (48 x 50 cm) and the maximum protected area is 2.53 ft2 (2350 cm2). If the fryer does contain a drainboard the maximum fryer dimensions for single nozzle coverage are 25- 3/8" x 191/2" (65 x 48 cm) and the maximum protected area is 3.44 ft2 (3195 cm2). However, the maximum hazard area must not exceed 19" x 19 1/2" (48 x 50 cm). The nozzle must be located along or anywhere within the protected area. Nozzle heights must be within 36 to 48 inches (91.44 - 121.92 cm) above the appliance surface and aimed to the center of the hazard area of the appliance. 'F Locate nIa within shad (sb. the Protected o r. AIM POINT (CENTER OF HAZARD rt 5i Front -- FULL VAT FRYER WITHOUT DRAINBOARO Note: Maximum & minimum heights must be measured vertically from the tip of nozzle to the top of the appliance. PULL VAT FRYER WITH DRAINBOARD LOW PROXIMITY APPLICATION FRYER PROTECTION (FULL VAT) TWO (2) SINGLE FLOW POINT NOZZLE (PIN 11982) MAXIMUM AREA: 19% in. (50 cm) X 25 3/8 in. (65 cm) (including drainboard interface area) 191/2 in. (50 cm) x 19 in. (48 cm) (not including drainboard interface area) A pair of Amerex single flow point nozzles (P/N 11982) will protect a full vat fryer. The nozzles must be used in pairs located on the perimeter of the appliance, %" back from the inside edge of the appliance and within a zone extending 6" in both directions of the center of the hazard. The nozzles are to be located 1800 apart (directly across from one another). They are to be aimed at a point 3" below the top of the appliance and directly below the opposing nozzle. If the fryer does not include a drainboard, the maximum fryer dimensions are 191/2" x 19" (50 x 48 cm) and the maximum protected area is 2.53 ft2 (2530 cm 2). If the fryer does contain a drainboard, the maximum fryer dimensions are 25 3/8" x 19 /2" (65 x 50 cm) and the maximum protected area is 3.44 ft2 (3195 cm2). However, the maximum hazard area must not exceed 19 %" x 19" (50 x 48 cm). The nozzle's height must be within 17%" to 36" (45 — 92 cm) above the appliance surface. October 2003. : 'Sectiôr 3 Peign Page .3 7 Aerex KPW.Ø:ChclSythem (EX 4658 FRYER PROTECTION (SPLIT VAT) TWO FLOW POINT NOZZLE (P/N 13729) MAXIMUM AREA: 14 in. (35.5 cm) X 21 in. (53.5 cm) (including drainboard interface area) 14 in. (35.5 cm) x 15 in. (38.1 cm) (not including drainboard interface area) The Amerex fryer nozzle (P/N 13729) uses two flow points and will protect a split vat fryer. If the fryer does not include a drainboard, the maximum fryer dimensions for single nozzle coverage are 15" x 14" (38.1 x 35.5 cm) and the maximum protected area is 1.46_ft2 (1356 cm2). If the fryer does contain a drainboard, the maximum fryer dimensions for single nozzle coverages are 21" x 14" (53.5 x 35.6 cm) and the maximum protected area is 2.0422 (1897 cm2). However, the maximum hazard area must not exceed 15" x 14" (38.1 x 35.5 cm). The nozzle must be located within the protected area on a line perpendicular to the longest side of the fryer passing through the center of the hazard area. Nozzle heights must be within 40 to 50 inches (101.6 - 127 cm) above the appliance surface and aimed to the center of the hazard area of the appliance. SPLIT VAT FRYER WITH DRAINBOAFD Locate nozzle within shaded area (above the protected area) AIM POINT (CENTER OF HAZARD AREA) - . - .-... .. - •jL.t;. 50' 40' SPLIT VAT FRYER WITHOUT DRAINOARI) NOTE: Maximum and minimum heights must be measured vertically from the tip of nozzle to the top of the appliance. SPLIT VAT FRYER WITH DRAINBOARD FRYERS EXCEEDING SINGLE NOZZLE PROTECTION: Multiple Amerex fryer nozzles (P/N 13729) may be used to protect single vat fryers with maximum protected areas exceeding single vat coverages up to a maximum protected area of 6 ft.2. The fryer must be divided into modules for single nozzle coverages and the nozzle located and aimed for each module as indicated for single nozzle coverages. For modules that do not include drainboards, the maximum module dimensions for single nozzle coverages is 19 %' x 19" (50 x 48 cm) and the maximum protected area is 2.53 ft2 (2350 cm2). If the module does contain a drainboard, the maximum module dimensions for single nozzle coverage is 25 3/8" x 19 1/2 (65 x 50 cm) and a maximum protected area is 3.44 ft2 (3195 cm2). However, the maximum frying area of a module must not exceed 19 1/2 x 19" (50 x 48 cm). AIM POINTS October 2003 Section 3 Design Page 3 - 8 A, re KP Wet Chemical System (EX 4658) SINGLE BURNER RANGE PROTECTION ONE - 1/2 FLOW POINT NOZZLE (P/N 11984) The Amerex half (1,4) flow point nozzle (P/N 11984) will protect a single burner with a surface area of 18" x 18" (46 x 46 cm). The nozzles must be located on the perimeter of the burner and 20 to 24" (51 - 61 cm) above the burners surface. The nozzle is aimed at a point 7" above the center of the burner. 7' SINGLE BURNER RANGE PROTECTION - OVERHEAD ONE - 1/2 FLOW POINT NOZZLE (P/N 11984) The Amerex half (1/2) flow point nozzle (PIN 11984) will protect a single burner with a surface area of 18" x 18" (46 x 46 cm). The nozzles must be located directly above the center of the burner and 24 to 42" (61 - 107 cm) above the burners surface. The nozzle is aimed at the center of the burner. TWO BURNER RANGE PROTECTION - SINGLE FLOW POINT NOZZLE (P/N 11982) The Amerex appliance, plenum nozzle (PIN 11982) has one flow point and will protect a range surface area of 14" x 28" (36 x 71 cm). The center to center distance between burners must not exceed 14" (36 cm). The nozzle must be located 44 - 48" (112 - 122 cm) above the range surface and centered between the two burners. The range surface area is' measured from the outside of the burner to the outside of the burner. NOTE: Maximum and minimum heights must be measured from the tip of nozzle to the surface of the appliance. lu 18 12" October 2Q03 : 'ctibfl 3. Design Page Aéex K WétChemial Systé .... (EX45) RANGE PROTECTION SINGLE FLOW POINT NOZZLE (P/N 11982) The Amerex appliance plenum nozzle (P/N 11982) has one flow point and will protect a range surface area of 12" x 24" (31 x 61 cm). The center to center distance between burners must not exceed 12" (31 cm). The nozzle must be located 36— 50" (91 - 127 cm) above the range surface and centered between the two burners. The range surface area is measured from the outside of the burner to the outside of the burner. Note: Maximum & minimum heights must be measured from the tip of nozzle to the surface of the appliance. RANGE PROTECTION MULTIPLE NOZZLES (P/N 11982) For ranges that have a surface area exceeding the capabilities of a single appliance nozzle, multiple nozzles must be used provided that the surface area of the range is divided into equally sized modules. Each module must be equal to or less than 12" x 24" (31 x 61 cm). Note: Maximum & minimum heights must be measured from the tip of nozzle to the surface of the appliance. PROTECTION OF BACK SHELVES Confronted with a back shelf that obstructs the spray pattern of the protecting nozzle? Locate the nozzle so that it is below the shelf and still within its listed minimum. When the shelf interferes . with the proper nozzle orientation it may be necessary to route the pipe under the shelf or provide a hole in the shelf for the nozzle. Always receive agreement on shelf alterations before performing the work. NOZZLE PN14178 BACK SHELF 18" MINIMUM NOZZLE HEIGHT L - FOUR BURNER RANGE August 2004 .... : . section 3 Déig n Page 3 - 9A Amerex KP Wet Chemical System (EX 4658) RANGE PROTECTION TWO - HALF FLOW POINT NOZZLE (P/N 11984) The Amerex appliance nozzle (P/N 11984) has one-half flow point value and when used as a pair as illustrated below will protect a range surface area of 12" x 36" (31 x 92 cm). The nozzle must be located 20 - 30" (50.8 - 76.2 cm) above the range surface, on the burner centerline, 2 inches (5 cm) outboard of the burner and aimed at the center of the hazard area. The nozzles are to. be at the same height and on opposite sides of the range hazard area. 36" H ER ~'W A 111 0 iii=11 A PAN O~M MAN M~A FAI I M~M ON PAN I Ar P4~014"-1 IN 'ArMAMMAIM TOP VIEW H Note: Maximum & minimum heights must be measured from the tip of nozzle to 20 30 ' the surface of the appliance. PLAN VIEW RANGE PLUS BACK-SHELF PROTECTION OVERHEAD APPLIANCE NOZZLE (P/N 11982) The Amerex appliance nozzle (P/N 11982) has a one flow point value and will protect a range burner area of 12" x 24" (31 X 61 cm) from an overhead position. The back shelf must be at least 20" high (51 cm) and must not cover more than 11" (28 cm) of the back burners. The nozzle must be located 40- 47" (102- 119 cm) above the range surface, on the burner centerline, 4-6 inches (10 - 15 cm) forward of the center of the two burners and aimed at the center of the hazard area. Note: Maximum & minimum heights must be measured from the tip of nozzle to the surface of the appliance. 24" cumP 12' OP VIEW r EDGE 4'-6' 40'-47' 20" MIN, MAX. I-I l 11' PLAN VIEW A.dgupt 1 •$eôfion3 Design Page Aee .:KP Wet,QheIiiiC6I System (EX 4658) CLOSED TOP CHAIN BROILER SINGLE FLOW POINT NOZZLE (PIN 11982) EXTERNAL The Amerex appliance/plenum nozzle (P/Ni 1982) has one flow DRIP PAN point and will protect a closed top chain broiler with a cooking area of 24 1/2" x 31" (62 X 79 cm). The nozzle is to be located on the side opposite the external drip pan (when present), positioned in the middle of the inlet opening and aimed at the opposite rear corner. TOP VIEW NOZZLE AIMED TO THE REAR OPPOSITE CORNER OF THE BROILING AREA. NOZZLE LOCATED IN THE CENTER OF THE IN-LET OPENING I . FRONT VIEW EXTERNAL DRIP PAN CLOSED TOP CHAIN BROILER I I EXTERNALI ri I DRIP PAN TOP VIEW L NOZZLE LOCATED 2" BEHIND THE EDGE OF THE OPENING AIMED TO THE CENTER OF THE \ OPENING- 10" x 10" MINIMUM OPENING \ 12"-36" NOZZLE \ HEIGHT ABOVE \ APPLIANCE N N OPEN TOP CHAIN BROILER TWO FLOW POINT NOZZLE (PIN 13729) The Amerex fryer nozzle (P/N 13729) has two flow points and will protect an open top chain broiler with a cooking area of 241/2"x 31" (62 x 79 cm). The minimum opening is 10" x 10" (25.4 x 25.4 cm) and the nozzle is to be positioned 2" behind the edge of the opening, at a height of 12" - 36" (30.5 - 91 cm)above the appliance and aimed at the center of the opening. Note: Maximum & minimum heights must be measured from the tip of nozzle to the surface of the appliance. FRONT VIEV EXTERNAL DRIP PAN October 2003 . ..' : .. Section3. •. esin ...,. •. Page $-10 Amerex KP Wet Chemical System (EX 4658) FOUR (4) BURNER RANGE PROTECTION TWO (2) FLOW POINT NOZZLE (P/N 14178) The Amerex 4 burner range nozzle (PIN 14178) has two (2) flow points and will protect a range surface area of 24" x 24" (61 x 61 cm). The center to center distance between burners must not exceed 12 inches. The nozzle must be located 18 - 50" (46 - 127 cm) above the range surface and centered between the burners. The nozzle is aimed straight down at the center of the appliance. NOTE: Maximum and minimum heights must be measured from the tip of nozzle to the surface of the appliance. RANGE PROTECTION—MULTIPLE NOZZLES (P/N 14178) For ranges that have a surface area exceeding the capabilities of a single nozzle, multiple nozzles must be used provided that the surface area of the range is divided into equally sized modules. Each module must be equal to or less than 24" x 24" (61 x 61 cm). NOTE: When using this nozzle to protect a two (2) burner range the aiming point is where an 8.50" radius from the center of each burner crosses one another 50' WOK PROTECTION SINGLE FLOW POINT NOZZLE (PIN 11982) The Amerex appliance plenum nozzle (P/N 11982) has one flow point and will protect a wok with dimensions between a minimum diameter of 14" (36 cm) and a maximum diameter of 24" (61 cm) inclusive. The wok must have a height dimension between a minimum of 4" (10 cm) and a maximum of 7" (18 cm) inclusive. The nozzle must be centered over the center of the wok and located at a height between 40 (102 cm) and 50" (127 cm) from the bottom of the inside of the wok and aimed at the center of the wok. 24 14 max. EEII Mm. Size Max. Size _-i _________ \4" mm. 7'max. 50 max. Aim Point _ of Intersection UM POINT Perimeter of Grlddl 11 Square Centered on Griddle 11' square centered on griddle center October 2003 .SetiOn 3 Design :. Paçé 3— 1. •. •: •. •. Ahere KP Wet théiôàI Sy1, (X.46). GRIDDLE PROTECTION - SINGLE FLOW POINT NOZZLE (P/N 11982) The Amerex griddle nozzle (P/N 11982) has one flow point and will protect a griddle surface of 36 inches wide (91 cm) x 30 inches deep (76 cm). The nozzle must be located along the perimeter of the appliance and within a vertical height range from 30" to 48" (76 - 122. cm) above the surface of the appliance. The aiming point for the nozzle is the "point of intersection" of a straight line from the nozzle location to the center of the appliance, with an 11" (28 cm) square, generated about the center point of the griddle. max. mm. I9llSquare Centered on Griddle Center Note: Maximum & minimum, heights must be measured from the tip of nozzle to the surface of the appliance. 48 Nozzle Location GRIDDLE PROTECTION - MULTIPLE SINGLE FLOW POINT NOZZLES (P/N 11982 Multiple Amerex griddle nozzles (PIN 11982 - one flow point) may be used to protect a griddle surface area greater than 30 inches (76 cm) X 36 inches (91 cm). The griddle must be divided into modules for single nozzle coverage and the nozzles located and aimed for each module as indicated for single nozzle coverage. 11" square centered on griddle center - Perimeter of Griddle .—Modules max mm. uare. 'red on Its Module Note: Maximum & minimum heights must be measured from the tip of nozzle to the surface of the appliance. Point of Intersection AIM POINT for nozzle protecting this module lzzle Location jare centered die center 12c)'i2 NOR' 11 301 max October 2Q03 ': ': Section 3. ,•De.i Páge..3 —12 Amerex KP Wet Chemical System (EX 4658) GRIDDLE PROTECTION - OVERHEAD TWO FLOW POINT NOZZLE (P/N 13729) The Amerex fryer and griddle nozzle (P/N 13729) has two flow points and will protect a griddle surface of 42 inches wide (107 cm) X 30 inches deep (76 cm). The nozzle must be located within 6 inches (15 cm) of either side of the appliance centerline, placed 38 inches (97 cm) to 50 inches (127 cm) above the cooking surface and aimed straight down. Note: Maximum & minimum heights must be measured from the tip of nozzle to the surface of the appliance. 09 500 i ijii 38 I Ii 12" square centered on griddle center GRIDDLE PROTECTION - OVERHEAD MULTIPLE TWO FLOW POINT NOZZLES (PIN 13729) Griddles exceeding 30 inches (76 cm) X 42 inches (107 cm) may be protected using multiple two flow point nozzles by dividing the surface area into equal modules. Each module requires one nozzle and cannot exceed an area larger than 42 inches length (107 cm) X 30 inches deep (76 cm). uare centered Idle center 120 120 12f. .30m max. 840 max 42x Note: Maximum & minimum heights must be measured from the tip of nozzle to the surface of the appliance. Note Maximum & minimum heights must be measured from the tip of nozzle to the surface of the appliance. Perimeter of Griddle of Intersection tIM POINT n 11 Square Centered on Griddle #. .. I *1 24" max. : "'r• mk I --'i----: 15" mm. 1 I •• - NZL 'Square interedon iddie Center of intersection UM POINT 11" Square Centered on Griddle Perimeter of Griddle NoIe Location October 2003 Section 3 Design Page 3 - 13 Amerex KP Wet Chemical System (EX 4658) GRIDDLE PROTECTION - LARGE TWO (2) FLOW POINT NOZZLE (P/N 14178) The Amerex Range Nozzle (P/N: 14178) has two (2) flow points and will protect a griddle surface of 48 inches wide (122 cm) x 30 inches deep (76 cm). The nozzle must be located along the perimeter of the appliance and within a vertical height range from 24" (61 cm). to 50" (127 cm) above the surface of the appliance. The aiming point for the nozzle is the "Point of Intersection" of a straight line from the nozzle location to the center of the appliance, where the line crosses the outer edge of an 11 inch square (28 cm sq.), centered over the center point of the griddle. ISO,, max. .&,-. •? 24 mm. - I I NeX1 ;?4 I: ,'r Square Centered on Griddle Center 11' square centered on griddles center GRIDDLE PROTECTION - LOW PROXIMITY TWO (2) FLOW POINT NOZZLE (P/N 14178) The Amerex Range Nozzle (PIN: 14178) has two (2) flow points and will protect a griddle surface of 48 inches wide (122 cm) x 30 inches deep (76 cm). The nozzle must be located at any one of the four corners of the appliance and within a vertical height range from 15" (38 cm) to 24" (61 cm) above the surface of the appliance. The aiming point for the nozzle is the "Point of Intersection" of a straight line from the nozzle location to the center of the appliance, where the line crosses the outer edge of an 11 inch square (28 cm sq.), centered over the center point of the griddle. Note: Maximum & minimum heights must be measured from the tip of nozzle to the surface of the appliance. \ /7 24 \\I// 15 11 square centered on module center OOtobèr 2003 S èction .3 Design Padd 3 14 KP Wet Chemical System. (EX 48) UPRIGHT BROILER PROTECTION TWO HALF FLOW POINT NOZZLES (P/N 11984) Two Amerex upright broiler nozzles are required for this application. Each upright broiler nozzle (P/N 11984) equals a % flow point. These nozzles must always be used in pairs equaling one flow point and will protect an internal broiler chamber measuring 30 1/2" X 28 %" (77 x 72 cm). The nozzles must be positioned at the front opening of the broiler with the top nozzle located above the grate, aimed toward the opposite rear corner and the lower nozzle located the grate and aimed toward the center of the drip pan. UPRIGHT BROILER MING ¼MBER CHAM RIP PA? FRONT MEW SIDE VIEW NOTE: PROTECTION FOR SALAMANDERS AND CHEESE MELTERS UP TO 38" (96.5cm) IN LENGTH SHOULD BE ACCOMPLISHED USING A SINGLE FLOW APPLIANCE NOZZLE P/N 11982 LOCATED IN THE MIDDLE OF THE OPENING AND AIMED AT THE REAR OPPOSITE CORNER. OPTIONAL : PROTECTION MAY ALSO BE ACCOMPLISHED BY USING TWO HALF FLOW POINT NOZZLES PNI 1984 , BOTH NOZZLES LOCATED ON THE SAME SIDE OF THE SALAMANDER, POSSITIONED IN THE MIDDLE OF THE UPPER AND LOWER OPENING, AIMED TO THE REAR OPPSITE CORNER. .11 \ .. 7. ' ' I ill • Nate: Max. & Min. heights must be measured from the lip of nozo to the top of the cooking surface. October 2003 Section 3. Design Pàgé:3 H1 Amerex KP Wet Chemical System (EX 4658) GAS RADIANT CHARBROILER PROTECTION SINGLE FLOW POINT NOZZLE (P/N 11982) One Amerex plenum nozzle (P/N 11982) will protect a gas radiant charbroiler with a cooking surface measuring 24 inches X 24 inches (61 x 61cm) maximum. The nozzle uses one flow point. It must be located 18 to 48 inches (46 - 122 cm) above the cooking surface and anywhere along or within the perimeter aimed towards the center. ELECTRIC RADIANT CHARBROILER PROTECTION SINGLE FLOW POINT NOZZLE (PIN 11982) Note: Electric charbroilers with a non-grated surface or a solid ribbed surface may be protected using the same limitations as a griddle. Electric charbroilers with an open grate may be protected with one Amerex appliance, plenum nozzle (P/N 11982) provided that the area is no larger than 24 inches X 24 inches (61 x 61 cm). The nozzle uses one flow point and must be located within 18 - 48 inches (46 - 122 cm) above the grate surface, anywhere along or within the perimeter of the protected area, aimed towards the center. LAVA ROCK (CERAMIC/SYNTHETIC) CHARBROILER SINGLE FLOW POINT NOZZLE (P/N 11983) A single Amerex solid fuel appliance plenum nozzle (P/N 11983) will protect a lava rock charbroiler with a maximum cooking surface of 24 inches wide (61 cm) by 24 inches deep (61 cm). The appliance nozzle uses 1 1/2 flow point and for this application must be located between 18 to 44 inches (46 to 122 cm) above the cooking surface anywhere along or within the perimeter of the appliance aimed toward the center. NiA - ' Afl" 6" .-, Max. Solid Fuel - Charcoal 11" - Max. Solid Fuel - Mesquite Logs 'I. October 2003 Section 3 Design Page 3 - 16 Amerex Al' Wet Chem ical System (EX 4658) SOLID FUEL APPLIANCES NATURAL AND MESQUITE CHARCOAL CHARBROILER PROTECTION ONE AND ONE HALF (11/2) FLOW POINT NOZZLE (P/N 11983) One Amerex solid fuel appliance nozzle (P/N 11983) will protect a charcoal charbroiler with a cooking surface measuring 281/2 inches x 24 inches (72 cm x 61 cm) maximum. The nozzle uses one and one half flow points. It must be located 16 to 42 inches (41 cm - 107 cm) above the cooking surface and anywhere along or within the perimeter aimed at the center. The fuel depth is limited to 6 inches (15 cm) maximum. 6" -,. Max. MESQUITE CHIPS & CHUNKS CHARBROILER ONE AND ONE HALF (1/2) FLOW POINT NOZZLE (P/N 11983) A single Amerex solid fuel appliance nozzle (P/N 11983) will protect a mesquite charbroiler with a maximum cooking surface of 281/2 inches X 24 inches (72 cm X 61 cm). The nozzle uses one and one half (11/2) flow points and for this application must be located between 16 to 48 inches (41 cm to 122 cm) above the cooking surface anywhere along or within the perimeter of the appliance aimed at the center of the appliance. The fuel depth is limited to 6 inches (15 cm) maximum. Solid Fuel - Mesquite Chips & Chunks MESQUITE LOG CHARBROILER ONE AND ONE HALF (11/2) FLOW POINT NOZZLE (P/N 11983) A single Amerex solid fuel appliance nozzle (PIN 11983) will protect a mesquite log charbroiler with a maximum cooking surface of 281/2 inches X 24 inches (72 cm X 61 cm). The nozzle uses one and one half (11/2) flow points and for this application must be located, between 19 to 44 inches (48 cm to 112 cm) above the cooking surface anywhere along or within the perimeter of the appliance aimed at the center of the appliance. Solid fuel is limited to three (3) layers of logs or 11 inch (28 cm) maximum stacked height. July 2006 ... ., Section 3 Design 1 Page 3 - 16A ..: 1: . :. :•. ..: Amex kP.WétChèh*al Systé EX.4658) NIECO MODEL 9025 -BURGER KING CHAIN BROILER TWO - SINGLE FLOW POINT NOZZLE (P/N 11982) The Nieco Chain Broiler Model 9025 is a unique appliance and when fitted with two catalysts it requires the use of two Amerex nozzles (P/N11982)to protect each half of the appliance. Total appliance protection therefore, requires the use of a total of four Amerex nozzles (P/N 11982). This unique appliance is actually two chain broilers put together to accommodate the cooking of two different products at the same time. This appliance can be fitted with two catalysts (18" x 24" overall) one for each cooking side. The protection of the appliance is accomplished by using two nozzles P/N 11982 positioned two inches outside of the catalyst perimeter aimed at the center point of the catalyst. The nozzles are to be located on opposite ends of the catalyst, 180° apart and are to be 13" to 36" above the top surface of the catalyst. This configuration is repeated for both cooking sides of the appliance. If no catalyst is used the same protection is required for the unit. Note: Maximum & minimum heights must be measured from the tip of nozzle to the top surface of the catalyst or appliance (if no catalyst is used). TOP VIEW L NOZZLE LOCATED 2' BEHIND THE EDGE OF THE CATALYST AIMED TO THE CENTER OF THE CATALYST - 18" x 24" k At' 12"-36"NOZZLE HEIGHT ABOVE CATALYST \\\ / FRONT VIEW INtII...O zjuzo CHAIN BROILER Appliance Nozzle PIN Flow Points Width Length Mm. Height Max. Height Deep Fat Fryer — without Drip Pan 13729 2 19 1/2 in. 19 in. 36 in. 48 in. Deep Fat Fryer—with Drip Pan 13729 2 19 1/2 in. 253/8 in. 36 in. 48 in. Deep Fat Fryer — with Drip Pan Low Proximity 2-11982 2 19 1/2 in. 253/8 in. 171/2 in. 36 in. Range — Single Burner _11984 _% 18 in. 18 in. 20 in. 42 in. Range — Two Burner _11982 1 14 in. 28 in. 44 in. 48 in. Range — Two Burner 11982 1 12 in. 24 in. 36 in. 50 in. Range- Two Burners w/Back Shelf 11982 _1 12 in. 24 in. 40 in. 47 in. Low Back-Shelf/Salamander— BS Manifold 17461 1 14 in. 42 in. 14 in. 19 in. Range - Three Burners 2-11984 1 12 in. 36 in. 20 in. 30 in. Range — Four Burners _14178 _2 24 in. 24 in. 18 in. 50 in. Wok _11982 _1_ 14-24 dia. 4-7 depth 40 in. 50 in. Griddle 11982 1 30 in. .36 in. 30 in. 48 in. Griddle 13729 _2_ 30 in. 42 in. 38 in. 50 in. Griddle 14178 _2_ 30 in. 48 in. 15 in. 50 in. Upright Broiler 2-11984 _1_ 30% in. 28 1/2 in. - - Charbroiler (Lava Rock) 11983 11/2 24 in. 24 in. 18 in. 44 in. Charbroiler (Gas Radiant & Electric Radiant) 11982 1 24 in. 24 in. 18 in. 48 in. Chain Broiler - Closed Top 11982 _1 241/2 in. 31 in. - - Chain Broiler— Open Top 13729 2 241/2 in. 31 in. 12 in. 36 in. Chain Broiler— Nieco Model 9025 /Catalyst (2) 4-11982 2 18 in. 24 in. 12 in. 36 in. Natural & Mesquite Charcoal Charbroiler 11983 1 % 24 in. 28 1/2 1n. 16 in. 42 in. Mesquite Chips & Chunks Charbroiler 11983 1 % 24 in. 28 % in. 16 in. 48 in. Mesquite Log Charbroiler 11983 1 % 24 in. 28 1/2 in. 19 in. 44 in. Plenum Nozzle P/N Flow Points Nidth Length 10 ft. Single BankN-Bank 11982 1 4 ft. Duct Nozzle P/N Flow Points Max. Perimeter Diameter Length Max. Diagonal Rectangular 16416 1 50 in. - Unlimited 18.8 in. Circular 16416 1 - 16 in. Unlimited - Rectangular 2-11983 3 .100 in. - Unlimited 37.2 in. Circular 2-11983 3 - 32 in. Unlimited - Rectangular 3-11983 4 1/2 150 in. - Unlimited 55.9 in. Circular 3-11983 4 1/2 - 48 in. Unlimited - Protection is not limited to the items listed on this chart. Modulizing larger appliances Is an acceptable practice. See your Amerex KP Manual for additional information. C-C 0 0. C) C) CD C) CD D)Cn CD V., Cl) CD B AMEREX KP RESTAURANT SYSTEM NOZZLE APPLICATION CHART Possible location for Vent P' Mechanical Release Module (whO in cyl) Mechanical Mnd,iI (whO 1 n cyl) 1101 7-01 July 20O6 Section :.Design Page .3-1:8 I Ameéx KPWétChebal Syte.. (EX 4658.) AGENT QUANTITY AND CYLINDER SELECTION: After reviewing the hazards and determining the number and type of nozzles that will be required, the quantity of agent and the number and type of cylinders must be selected. Adding the number of flow points that are needed for the system will determine the agent quantity and cylinder options. ONE 2.75 GALLON CYLINDER (PIN 16921) WILL SUPPLY'SUFFICIENT AGENT FOR UP TO AND INCLUDING 8 FLOW POINTS. ONE 3.75 GALLON CYLINDER (P/N 13334) WILL SUPPLY SUFFICIENT AGENT FOR UP TO AND INCLUDING 11 FLOW POINTS. ONE 4.75 GALLON CYLINDER (PIN 17379) WILL SUPPLY SUFFICIENT AGENT FOR UP TO AND INCLUDING 14 FLOW POINTS. Cylinders may be used together for multiple cylinder systems with one MRM or PRM. A MAXIMUM OF 10 KP 275/375/475 AGENT CYLINDERS MAY BE USED PER MECHANICAL RELEASE MECHANISM OR PNEUMATIC RELEASE MODULE. ONE 6.14 GALLON CYLINDER (P/N 15196) WILL SUPPLY SUFFICIENT AGENT FOR UP TO AND INCLUDING 18 FLOW POINTS. A MAXIMUM OF 6 KP 600 AGENT CYLINDERS MAY BE USED PER MRM or PRM. ANY COMBINATION OF CYLINDERS INVOLVING THE KP600 CYLINDER IS LIMITED TO A TOTAL OF 6 CYLINDERS PER MRM or PRM. ACTUATION NETWORK LIMITATIONS - MRM OR PRM The actuation network for the Amerex KP Restaurant Fire Suppression System consists of factory supplied hose, installer supplied copper tubing or pipe that connects the MRM or PRM to each cylinder discharge valve. A single MRM or PRM is capable of actuating up to ten (10) 3.75/2.75 gallon agent cylinder discharge valves or six (6) 6.14 gallon agent cylinder discharge valves by discharging a single 10 in nitrogen cylinder (P/N 12856) through the actuation network. If the network is a combination of 2.75/ 3.75/ 4.75 & 6.14 gallon cylinders, then maximum number of cylinders is six (6). ID Note: A vent plug (P/N 10173) must be placed in an accessible location anywhere in the actuation line to aid in releasing pressure after the system has discharged. See the RECHARGE Section 7. LIMITATIONS (SINGLE OR MULTIPLE CYL SYSTEMS) Copper tubing - 1/4" O.D. refrigeration type with a minimum wall thickness of .049 inches. Use with brass or steel compression style fittings (with brass or steel sleeves or ferrules). Maximum length (including all fittings) 100 feet (30.48 m) High Pressure Hose - ¼" I.D. wire braid hose that is factory supplied. Maximum length (including all fittings) 54 feet (16.46 m) or a maximum number of 40 hose assemblies P/N 12854, 20 hose assemblies P/N 16448, or any combination that does not exceed a total of 54 feet (16.56 m) Pipe - 1/4" NPT schedule 40 made of stainless steel, galvanized, chrome plated or black iron pipe. Maximum length - 22.2 feet (6.77m) Maximum tees - 9 Maximum elbows - 9 (note: 2 —45° elbows = 90°) Note: Different methods of constructing the actuation network may be mixed provided that the shortest limitations are followed, Example: A mix of 1/4" copper tubing and ¼" high pressure hose requires that the hose limitations be followed (no more than 54 feet [16.46m]) for the complete network. A mix of ¼" high pressure hose and 1/4" pipe requires that the pipe limitations be followed (no more than 22.2 feet [6.77m]) for the complete work. Nitrogen Cylinder 10 cu ifl Maximum Total Length for: Feet Meters l/" Copper tubing 100 30.48 Hose 54 16.46 ¼" Schedule 40 Pipe 22.2 6.77 Up to ten (10) KP 275/375/475 Cylinders - maximum or up to six (6) KP 600 Cylinders - maximum July 2006 Section 3 :T esign Page 3-19 Amerex KP Wet Chemical System (EX 4658) A Supply Line is the distribution piping that runs from the distributor outlet or discharge fitting to the first splitting tee. MANUAL AC IIJA TO F <P375 COP PNEUMATIC MODULE A Supply Branch Line (including the last nozzle branch) is the distribution piping that runs. from the first tee at the hood to the last nozzle in the system including all fittings used to MANUAL exit the supply branch line. ACTUATOR KP375 CYLFN PNEUMATIC MODULE A Nozzle Branch Line is the distribution piping that runs from the supply branch tee splitting to the nozzles including all fittings used to exit the supply branch line. MANUAL ACTUATOR KP375 CYLINDI PNEUMATIC RI MODULE GENERAL PIPING REQUIREMENTS: All pipe used for the distribution network must be schedule 40 (black, chrome or stainless steel) pipe. Piping limitations are expressed in linear length of. pipe. Linear piping is the actual length of straight pipe used throughout the system. WARNING: GALVANIZED PIPE IS NOI ALLOWED Maximum flow point per cylinder: KP 275 = 8 flow points KP 375 = 11 flow points KP 475 = 14 flow points KP 600 = 18 flow points Twin KP 375 = 22 flow points NOTE: THESE ARE EXAMPLES ONLY" OTHER CONFIGURATIONS CAN BE DESIGNED Griddle Range Oótober 2003 Section 3: Design: Pagé 3 -20 Amerex KP Wet Chemical Sys te (EX 4658) m TYPICAL DISTRIBUTION NETWORK FOR SINGLE CYLINDER SYSTEM . -j Duct 4 Feet SuppIy -ri Supply Branch Plenui 10 Feet F \\ Fryer - E!J Distributo STRAIGHT PIPING SYSTEM Duct Supply Branch 4FeetMc 4 Nozzle Wok Branch Fryer Supply Line YY Branch Plenum Nozzle 10 Feet Max Griddle I (Overhead) Range 1 Distributor SPLIT PIPING SYSTEM NOTE: The schematics äbov&do not iepresent the only configurations possible - they are informational only October 2003 Section 3 Design Page 3 - 21 Amerex KP Wet Chemical System (EX 4658) TYPICAL DISTRIBUTION NETWORK FOR TWIN (KP 375) CYLINDER SYSTEM - a wt /2&çya-ó We Gas Rd I- Raim Fbve Wok III Il Node aatfi STRAIGHT PIPING SYSTEM Duct Duc _________ '_ Supply _Branch 4 Feet Max. I 34 Supply Line I Wok iFryer1t 10 Feet Max. lenum I FiDistributors Griddle Range Manifolded Nozzle '/8qiozz Brbncl 34 Nozzle Branch 4 Feet -,,. Gas Radiant Charbroiler Max. SPLIT PIPING SYSTEM NOTE: The schèmàtiôslabbve do not répreseñt the only 'configurations possible —they, are informational only. July 2006 Section 3 Design Page 3 - 22 Amerex KP Wet Chemical System (EX 4658) KP DISTRIBUTION PIPING DESIGN LIMITS FOR ALL CYLINDER SIZES When designing a KP system to protect a kitchen containing a Fryer, Wok or Range, the following MINIMUM TOTAL SYSTEM PIPING must be used in accordance with the chart below: SUPPLY LINE LIMITATIONS: All DiDe and fittinas runninu from the distributor hlock or thp di--,rhqrnP fiftino to thiz fircf fina CYLINDER FLOW POINTS PIPE SIZE MAXIMUM LINEAR FEET OF PIPE MAX. QTY. TEES MAX. QTY. ELBOWS MAX. QTY. BUSHINGS VI, - NU I t: i. use iio suppiy iine oniy wnen au piping is to De 31ö" pipe. 2. The supply line has a maximum vertical rise above the distributor of 10 feet. SUPPLY BRANCH LINE (including last nozzle branch) LIMITATIONS: All pipe and fittings leaving the first splitting tee in the system and ending with the last nozzle in the last branch line. While the last nozzle branch is included in the piping limitations for the supply branch line, the limitation (pipe size and maximum length) for nozzle branch lines apply to this portion of the supply branch line. CYLINDER FLOW POINTS PIPE SIZE MAX. FEET OF PIPE STRAIGHT MAX. FEET OF PIPE SPLIT MAX. QTY. TEES MAX. QTY. ELBOWS MAX. QTY. REDUCING BUSHINGS NO I : ]. In a single 3.15 t.allon Straigrit Hpe System, 5' 01 pipe may be transferred from the supply line to the supply branch line. * 2. The use of 3/8" pipe with two manifold KP375s is only permitted when the SUPPLY LINE length is equal to or less than 20'. NOZZLE BRANCH LINE LIMITATIONS: All pipe and fittings leading from the supply branch tee to a system nozzle. CYLINDER FLOW POINTS PIPE SIZE TOTAL LINEAR FEET OF PIPE MAX. QTY. TEES MAX. QTY. I ELBOWS MAX. QTY. BUSHINGS 11 s 1; I' 1 - GENERAL SYSTEM LIMITATIONS: No %" pipe nozzle branches shorter than 12" long. Nozzle types may not be mixed on any nozzle branch line and a maximum of 4 flow points. The discharge fitting, distributor and distribution hose are not to be included in any calculations. No mixing of pipe sizes is allowed within pipe categories. Example: if one nozzle branch is to be %" pipe then all must be %" pipe. 1/2 pipe for nozzle branch lines is allowed only in an 11 flow point system. Duct nozzle has a maximum vertical rise above the supply branch line of 4'0". October 2003 Section 3 Design Page 3 - 23 Amerex KP Wet Chemical System (EX 4658) DETECTION NETWORK LIMITATIONS: MRM Optimum fire suppression system performance relies on proper detection network design. This section discusses the type of detectors used, their selection, placement and design limitations. The Amerex KIP Restaurant Fire Suppression System MRM uses a continuous cable, corner pulleys, detector bracket, detector linkage, fusible links, conduit offset, terminal link connector and a temperature-measuring device. The quantity of detectors to be used in a system will depend on the number of ducts, number of appliances and the location of the appliances under the hood. DETERMINING DETECTOR LOCATION AND NUMBER OF DETECTORS In order to detect a fire in the duct, a detector is required to be placed within the duct opening or up to 12 inches into the duct. If it is mounted into the duct, the bracket cannot shield the fusible link from the hot vapors moving through the duct. Every appliance under the hood that is being protected by the suppression system must have a detector placed over it and positioned within the path of exhaust vapors. WARNING: DO NOT LOCATE DETECTORS DIRECTLY IN THE PATH OF GAS APPLIANCE EXHAUST FLUE GASES. DOING SO COULD RESULT IN UNNECESSARY DISCHARGE OF THE SYSTEM. GENERAL LIMITATIONS OF DETECTION NETWORK: Niç Maximum of 24 corner pulleys. (either style) Maximum of 20 detectors (any combination of temperature settings). Maximum of 120 feet of cable on the detection network. No pulley tees are allowed. Remote manual pulls are not allowed on the detection network. Maximum of I conduit offset (must be located at mechanical release module when chosen). ATTACH DETECTION NETWORK 12 O'CLOCK/ TO ANY ONE OF THREE SIDES. POSITION ur4uuuu 'rrtu (OPTIONA MRM POSITIO 6 O'CLOCK CABLE LENGTH AND CORNER POSITION PULLEY MAXIMUMS AS SPECIFIED P/N 12508 DETECTOR BRACKET ASSEMBLY MAXIMUM QUANTITY AS SPECIFIED. P/N 12859 TERMINAL LINK CLAMP INSTALL IN CONDUIT CONNECTOR OF LAST DETECTOR BRACKET ASSEMBLY. October 2003 Section 3 .DSgfl Page 3— 24 AmeréxKPWet chemical System (EX 4658). FUSIBLE LINK SELECTION To assure that the appropriate temperature is selected, the temperature sensing device must be used at each detector location while the cooking line and exhaust fan is operating. Temperatures found at each detector should be recorded and placed with other documentation in the job file for future reference. Selection of fusible links should be made according to the temperature measured: Globe Type "K" Standard Response Links Temperature Measured :1 .Lirik Rated Temp. .Pàrt No 700 to 150°F (21° to 65°C) 212°F (100°C) 12326 151° to 225°F (66° to 107°C) 280°F (138°C) 12327 226° to 300°F (21° to 65°C) 360°F (182°C) 12328 301° to 375°F (21° to 65°C) 450°F (232°C) 12329 376° (192°c) & above consult factory Consult factory Job Quick Response Links Temperature Measured bnk Rated Temperature Job Lik Part Number 70° to 150°F (21° to 65°C) 200°F (93°C) Quick Response 16225 1510 to 225°F (660 to 107°C) 286°F (141°C) Quick Response 16226 2260 to 300°F (108° to 149°C) 360°F (182°C) Quick Response 16227 DETECTION NETWORK LIMITATIONS: PRM Select a suitable location for the pneumatic release module (PRM) that has access for installation, service, recharge and where both the nitrogen actuation cylinder pressure gauge and the system status indicator can be viewed. The PRM has provisions for a single, continuous section of detection tubing. No splicing or "tee's" are allowed. There shall be only two tubing terminations - one at the accumulator cylinder inside the PRM and the other at the opposite end of the tubing, with the use of an End of Line fitting (P/N 16506). Install in areas where the maximum expected ambient temperature does not exceed 375°F. SEE SECTION 4 "INSTALLATION" FOR ROUTING INFORMATION ON DETECTOR TUBING PAGE 5 July 2006 Section 3. Design Page 3— 24A Amerex KP Wet Chemical System (EX 4658) LINEAR FUSIBLE LINK DETECTION NETWORK LINK TO LINK CABLE SEGMENT 24" MAX. 01ST. [LINK MAX. DiST. / LINK TO MRM FROM END OF HOOD I LINK TO LINK I / CABLE SEGME 4 Iw z / DUCT / 0 I PLENUM A TERMINAL CABLE CABLE EYE BOLT SUPPORT SEGMENT REQUIRED ON EACH SIDE 24" MAX. 01ST. FROM END OF HOOD OF THE DUCT TERMINAL CONNECTOR 4 EMT FITTING HANDY CONDUIT BOX 2118"X4" HOOD The Linear Fusible Link Detection System provides complete hood fire detection by placing thermal links at maximum 24" intervals the entire length of the hood. Installing the links in this manner allows the appliances to be placed anywhere under the hood without having to locate links directly over each appliance. A unique system of cable segments, pie-fabricated, has been developed to make the installation of this system simple and easy. It eliminates the use of conduit, link holders and mounting brackets under the hood in the plenum area. The limitations of the Linear Fusible Link Detection System are as follows: Maximum of 20 detection links and (19) Link to Link Cable Segments. Maximum of 30 feet of cable used in the Link to MRM Cable Segment. Maximum of 20 corner pulleys. (either style) Maximum unsupported detection cable length is 8'-0". Refer to Fusible Link Selection section, page 3-24 of this manual for proper selection process. The higher setting links are to be used when higher temperatures are encountered with appliances such as char-broilers. The Linear Fusible Link Detection System is for use in single hood applications, or where multiple hoods are connected "end to end" only. It can not be used for "back to back" hood arrangements or multiple hoods that are mounted in separate locations and are part of a single KIP Fire Suppression System. October 2003 : :SeciOn 3 Désign. Page 3 -25 Aebx KP Wet Chmica1'Systern (EX 4658).... MANUAL PULL STATION NETWORK LIMITATIONS Every Amerex KP Restaurant Fire Suppression System installation must have at least one manual pull station. The manual pull station network consists of cable, corner pulleys, pulley tee, manual pull station(s) and optional conduit offset. GENERAL LIMITATIONS OF MANUAL PULL STATION NETWORK Maximum of 20 corner pulleys per manual pull station Maximum of 130 feet of cable per manual pull station Maximum of I pulley tee per network (counts as one corner pulley for each manual pull station) Maximum of 1 conduit offset per network (must be attached to the MRM and before tee pulley when chosen) NOTE: Manual pull stations should be installed no higher than 48 inches from the floor and must be along a path of egress. Consult the local Authority Having Jurisdiction (AHJ) for the final approval for manual pull station quantity, locations and mounting height and other considerations prior to finalizing manual pull station mounting details. ATTACH MANUAL PULL STATION NETWORK TO ANY ONE OF THREE SIDES. 12 O'CLOCK/ OFFS - SINGLE STATION CONDUIT - POSITION (OPTIONAL) NETWORK - - MP orm PI~M 3 O'CLOCK LJ POSITION 6 O'CLOCK ! POSITION DENOTES SINGLE PATH FOR CABLE LENGTH & PULLEY QUANTITY CALCULATION. r MRM DUAL STATION or NETWORK P1M PULLEY NOTE: The manual pull station(s) are the only MANUAL means of activating the Amerex KP Restaurant Fire Suppression System. CONE (OPTI SINGLE GAS MRM VALVE OR NETWORK PRM I DENOTES 1-1-p nn r, fl CABLE LE QUANTI) AS IRK October2003 S'6Ction 3: Design Page 3-26 Amerex KP Wet Chemical System (EX 4658) MECHANICAL GAS VALVE APPLICATIONS The PRM or MRM closes the mechanical gas valve immediately upon system discharge. A pneumatic and mechanical action in the gas trip assembly pulls on a cable attached to the mechanical gas valve, unlatching the valve and allowing an internal spring within the valve body to provide the closing force. Connection of the cable from the valve to the PRM or MRM under tension maintains the gas valve in an open position. MECHANICAL GAS VALVE A mechanical gas valve trip assembly must be used with any mechanical gas valve. The gas valve trip assembly (P/N %11t9, 12740) is included with all Amerex manufactured gas valves but must be ordered separately for use with gas valves listed *40004 PORT NO. 12740 in this manual supplied by other manufacturers. See Section 3 "System Components" for all mechanical gas valves that are suitable for use with the Amerex Restaurant Fire Suppression System. The use of any other mechanical gas valves will avoid the UL listing for the system installation. All of the listed valves have female NPT threads. The location of the gas valve should be accessible and approved by the local Authority Having Jurisdiction. A contractor licensed and qualified for such work should perform installation of the mechanical gas valve into the gas line. MECHANICAL GAS VALVE ACTUATION NETWORK LIMITATIONS The mechanical gas valve actuation network consists of cable, corner pulleys, pulley tee, gas valve and conduit offset. GENERAL LIMITATIONS OF MECHANICAL VALVE NETWORK Maximum of 20 corner pulleys per mechanical gas valve of any listed type in KP Manual Maximum of 130 feet (39.6m) of cable per mechanical gas valve of any listed type in KP Manual Maximum of I pulley tee per network (counts as one corner pulley for each mechanical gas valve) Maximum of 1 conduit offset per network (must be located at pneumatic release module and before tee pulley when chose) October 2003 Sectibh• Design - -3 27 Are: KPY etChéical System ELECTRICAL GAS VALVE APPLICATIONS 110 VAC electrical gas valves may be used in place of the mechanical gas valves. The electric shut off valve used with the Amerex KP Restaurant Fire Suppression System must be UL listed for use with natural gas or propane, be held open by energizing an electric solenoid and be wired through a microswitch and manual release relay. A qualified electrician must do any field wiring and connections involving the shut down of electrical cooking equipment or an electric gas valve. P/N Size Manufacturer 12870 3/4" 11/2 12871 12872 11/4" 12873 12874 12875 2 1/2" 12876 ELECTRIC GAS VALVE OPERATION Power to the electric gas valve is run through the normally closed contact on a microswitch located in the pneumatic release module (PRM) or mechanical release module (MRM) to the manual reset relay and from the manual reset relay to the electric gas valve. In a normal (non fire) condition, current is allowed to flow to the solenoid on the electric gas valve, holding the valve open. In a fire condition, when the release module actuates the suppression system, the microswitch contacts will transfer, opening the normally closed contacts in the manual reset relay, interrupting current to the gas valve and cause it to close. Resetting the MRM or PRM and transferring the contacts back to a normal (normally closed) position will not cause the electrical gas valve to open. The manual reset relay must reset before current will flow to the valve and cause it to open. A loss in electrical power, even temporary or momentary, will require someone to manually reset the relay before the electrical gas valve will open again. NOTE: SEE WIRING SCHEMATICS NEXT TWO PAGES October 2003 . ... . Sctidh. 0és1 PèL-28: * .., AmtxPWØ ChèióaI System. (EX 465). POWER SOURCE NO ,NLLt.rc-rNUvluu JUPIU HUN UAt BASIC WIRING DIAGRAM POWER SOURCE RE YELLOW NUIH.: UL) NUI U YLLLOW WIRE ON MICROSWITCH IN NORMAL MICROS\MTCH INSTALLATION. THE YELLOW WIRE IS TO BE USED ONLY FOR EXTINGUISHER ALARM, LIGHT CIRCUITS, ETC. BASIC WIRING DIAGRAM RED (COMMON) Ii 120 V/6 0HZ L2 YELLOW (NO.) BLACK (NC.) MANUAL RESET RELAY T ±K lKa PUSHBUTTON KIbj SWITCH - - - I -J ---- MICROSWITCH I I - >( CURRENT DRAW MAX: 8A GAS VALVE NOTES: RESISTIVE 8A INDUCTIVE, SEE NOTE 3 DENOTES FIELD INSTALLATION ---- DENOTES FACTORY INSTALLATION GAS VALVE: UL LISTED ELECTRICALLY—OPERATED SAFETY VALVE FOR NATURAL OR LP GAS AS NEEDED OF APPROPRIATE PRESSURE AND TEMPERATURE RATING, 1I0V/60HZ OR AMEREX GAS VALVES, P/N 12870, 12871, 12872, 12873, 12874, 12875 AND 12876. Kla AND <lb ARE N.O. WHEN Xl IS OE—ENERGIZED. Qctdber•2003 Seotin 3 péign Aç PWèt Chemical .Sfe' EX 4658) INSTALLATION OVERVIEW 01— w..wM. ET rINMAY U.1C QM VALVE BASIC WIRING DIAGRAM p s UaJWM. PNClwr FALAY MICPO NOTE: DO NOT USE BLACK WIRE ON MICRO SWITCH IN NORMAL INSTALLATION. BLACK WIRE TO BE USED ONLY FOR EXTRANEOUS ALARM, LIGHT CIRCUITS, ETC. WIRING SCHEMATIC AND K1 b ARE N.O. WEN K1 IS DE—ENERGIZED. VMLM L. U.MJM. Owwr .AY 1 P1 •1 11ava rim L L L — -®-- —J -0---- ---i -®---J P NOTE 1.—DENOTES FIELD INSTALLATION. ------DENOTES FACTORY INSTALLATION. GAS VALVE' - UL USTED ELECTRICALLY—OPERATED SAFETY VALVE FOR NATURAL OR LP GAS AS NEEDED OF APPROPRIATE PRESSURE AND TEMPER1URE RATING, 110V/6OHr' OR AMEREX GAS VALVES, PART NUMBERS 12870,12871, 12872, 12873, 12874, 12875 AND 12876. INSTALLATION OVERVIEW