HomeMy WebLinkAbout6197 EL CAMINO REAL; ; AS0301148/15/24, 10:46 AM AS030114 Permit Data City of Carlsbad Sprinkler Permit 6197 EL CAMINO Job Address: REAL Permit Type: SPRINK Parcel No: 2131000700 Lot #: 0 Reference No.: PC #: Permit No: AS030114 Status: ISSUED Applied 6/12/2003 Approved: 7/14/2003 Issued: 7/14/2003 Inspector: Project Title: SAMMY STUDIOS Applicant: Owner: CALWEST INDUSTRIAL HOLDINGS L L C C/O DELOITTE & TOUCHE LLP 2235 FARADAY AVE #0 CARLSBAD CA Fees ($) I Add'I Fees ($) Total ($) Balance ($) 564.5 0 564.5 0 about:blarik 1/1 ASo3o I I+ - - Fire Protection by Computer Design PACIFIC FIRE SUPPRESSION LIC. #423418 / C-16 1642 S. CLEMENTINE ST. ANAHEIM CA 92802 714-502-0211 Job Name : SAMMY STUDIOS Building Location : 6197 EL CAMINO REAL, CARLSBAD, CA System Contract 03050 Data File : SAMMY.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PP1ç () 'J 1_' 16 0 423418 PACIFIC FIRE SUPPRESSION Page 2 SAMMY STUDIOS Date 5-27-03 Hydraulic Design Information Sheet Name - SAMMY STUDIOS Date - 5-27-03 Location - 6197 EL CAMINO REAL, CARLSBAD, CA Building - System No. - Contractor - Ift Contract No. - 03050 Calculated By - CHUCK HAMILTON Drawing No. - 2 OF 3 Construction: ( ) Combustible ( ) Non-Combustible Ceiling Height - Occupancy - OFFICES S ( X) NFPA 13 ( X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 427 System Type Sprinkler/Nozzle Density - 0.1 ( ) Wet Make TYCO D Area Per Sprinkler - 225 ( ) Dry Model 3231 E Elevation at Highest Outlet - 30 ( ) Deluge Size 1/2" S Hose Allowance - Inside - 100 ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 DEG. G Hose Allowance - Outside - 0 N Note Calculation Flow Required - 277.84 Press Required - 50.417 At BOR Summary C-Factor Used: 120 Overhead 120 Underground W Water Flow Test: Pump Data: A Date of Test - N/A T Time of Test - Rated Cap.- E Static Press - 90 @ Press - R Residual Press - 58.2 Elev. - 0 Flow - 1627 S Elevation - 0 U P Location - INFORMATION FROM HYDRAULIC PLACARD P L Source of Information Y Tank or Reservoir: Cap. - Elev.- Well Proof Flow EXISTING 6" RISER C Commodity Class O Storage Ht. Area M Storage Method: Solid Piled % M Single Row ( ) Conven. Pallet S R ( ) Double Row ( ) Slave Pallet TA Mult. Row 0 R K Flue Spacing A Longitudinal G E Horizontal Barriers Provided: Location Aisle W. Palletized % Rack Auto. Storage ( ) Encap. Solid Shelf ( ) Non Open Shelf Clearance:Storage to Ceiling Transverse Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) PACIFIC FIRE SUPPRESSION Page 3 SAMMY STUDIOS Date 5-27-03 City Water Supply: Cl - Static Pressure : 90 PSI C2 - Residual Pressure: 58.2 PSI C2 - Residual Flow : 1627 GPM 150 140 P 120 R 110 E 100 90 S 80 U 70 R 60 E 50 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW( N"1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Dl - Elevation : 5.197 PSI 02 - System Flow : 177.84 GPM D2 - System Pressure : 50.417 PSI Hose (Adj City) : GPM Hose ( Demand) : 100 GPM D3 - System Demand : 277.84 GPM Safety Margin : 38.374 PSI 130 - Cl - _ C2 0, I.I.I.I.I.I.... .... I.... .... Fittings Summary PACIFIC FIRE SUPPRESSION SAMMY STUDIOS Fitting Legend Abbrev. Name Page 4 Date 5-27-03 A Generic Alarm Va B Generic Butterfly Valve C Roll Groove Coupling D Dry Pipe Valve E 90' Standard Elbow F 45' Elbow G Gate Valve H 45' Grvd-Vic Elbow I 90' Grvd-Vic Elbow J 90' Grvd-Vic Tee K Detector Check Valve L Long Turn Elbow M Medium Turn Elbow N PVC Standard Elbow 0 PVC Tee Branch P PVC 45' Elbow Q Flow Control Valve R PVC Coupling/Run Tee S Swing Check Valve 1 90' Flow thru Tee U 45' Firelock Elbow V 90' Firelock Elbow W Wafer Check Valve X 90' Firelock Tee V Mechanical Tee Z Flow Switch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Summary PACIFIC FIRE SUPPRESSION Page 5 SAMMY STUDIOS Date 5-27-03 Unadjusted Fittings Table 1/2 3/4 1 11/4 11/2 2 21/2 3 31/2 4 A 7.7 21.5 17.0 B 7.0 10.0 12.0 C 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 D 9.5 17.0 28.0 E 2.0 2.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 F 1.0 1.0 1.0 1.0 2.0 2.0 3.0 3.0 3.0 4.0 G 1.0 1.0 1.0 1.0 2.0 H 1.0 1.5 2.0 2.0 3.0 3.0 3.5 3.5 I 2.0 3.0 4.0 3.5 6.0 5.0 8.0 7.0 J 4.5 6.0 8.0 8.5 10.8 13.0 17.0 16.0 K 14.0 14.0 L 1.0 1.0 2.0 2.0 2.0 3.0 4.0 5.0 5.0 6.0 M 2.0 2.0 3.0 3.0 4.0 5.0 6.0 6.0 8.0 N 7.0 7.0 7.0 8.0 9.0 11.0 12.0 13.0 0 3.0 3.0 5.0 6.0 8.0 10.0 12.0 15.0 P 1.0 1.0 1.0 2.0 2.0 2.0 3.0 4.0 Q 18.0 29.0 35.0 R 1.0 1.0 1.0 1.0 1.0 1.0 2.0 2.0 S 4.0 5.0 5.0 7.0 9.0 11.0 14.0 16.0 19.0 22.0 T 3.0 4.0 5.0 6.0 8.0 10.0 12.0 15.0 17.0 20.0 U 1.8 2.2 2.6 3.4 V 3.5 4.3 5.0 6.8 W 10.3 X 8.5 10.8 13.0 16.0 Y 2.0 4.0 5.0 6.0 8.0 10.5 12.5 15.5 22.0 Z 2.0 2.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 5 6 8 10 12 14 16 18 20 24 17.0 27.0 29.0 9.0 10.0 12.0 19.0 21.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 47.0 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 5.0 7.0 9.0 11.0 13.0 17.0 19.0 21.0 24.0 28.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 11.0 13.0 4.5 5.0 6.5 8.5 10.0 18.0 20.0 23.0 25.0 30.0 8.5 10.0 13.0 17.0 20.0 23.0 25.0 . 33.0 36.0 40.0 21.0 25.0 33.0 41.0 50.0 65.0 78.0 88.0 98.0 120.0 36.0 55.0 45.0 8.0 9.0 13.0 16.0 18.0 24.0 27.0 30.0 34.0 40.0 10.0 12.0 16.0 19.0 22.0 33.0 27.0 32.0 45.0 55.0 65.0 76.0 87.0 98.0 109.0 130.0 25.0 30.0 35.0 50.0 60.0 71.0 81.0 91.0 101.0 121.0 4.2 5.0 5.0 8.5 10.0 13.0 13.1 31.8 35.8 27.4 21.0 25.0 33.0 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD PACIFIC FIRE SUPPRESSION Page 6 SAMMY STUDIOS Date 5-27-03 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. KDI 0.0 5.6 16.14 na 22.5 .1 225 16.143 1 12.0 K= K@ DPI 17.51 na 22.5 2 12.0 K= K@ DPi 19.24 na 23.58 3 12.0 23.63 na 4 30.0 35.82 na 5 30.0 37.22 na 6 30.0 11.2 34.59 na 65.87 .1 96 7.0 7 30.0 37.23 na 8 30.0 11.2 34.6 na 65.88 .1 96 7.0 9 30.0 37.23 na TOR 30.0 37.28 na HOSE 0.0 50.42 na 100.0 BOR 0.0 50.42 na The maximum velocityis 16.14 and it occurs in the pipe between nodes 2 and 3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fial Calculations - Standard PACIFIC FIRE SUPPRESSION Page 7 SAMMY STUDIOS Date 5-27-03 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn HD1 22.50 1.08 IT 5.762 4.000 16.143 K Factor 5.60 to 120 5.762 0.0 DPI 22.5 0.1404 9.762 1.371 Vel = 7.880 0.0 22.50 17.514 KFactor 5.38 1 22.50 1.08 12.300 17.514 K Factor @ node DPl to 120 0.0 0.0 2 22.5 0.1404 12.300 1.727 Vel= 7.880 2 23.58 1.08 8.300 19.241 K Factor @ node DPl to 120 0.0 0.0 3 46.08 0.5289 8.300 4.390 Vel = 16.138 3 0.0 1.408 41 6.617 100.000 23.632 to 120 5L 2.206 37.494 -7.796 4 46.08 0.1454 137.494 19.987 Vel = 9.495 4 0.0 2.635 21 16.474 170.000 35.825 to 120 32.948 0.0 5 46.08 0.0069 202.948 1.394 Vel= 2.711 5 0.0 6.357 2L 11.316 62.000 37.219 to 120 22.632 0.0 7 46.08 0.0001 84.632 0.008 Vel = 0.466 0.0 46.08 37.227 K Factor= 7.55 6 65.87 2.635 2T 16.474 165.000 34.593 KFactor= 11.20 to 120 32.948 0.0 7 65.87 0.0133 197.948 2.634 Vel = 3.875 7 46.09 6.357 12.000 37.227 to 120 0.0 0.0 9 111.96 0.0005 12.000 0.006 Vel= 1.132 0.0 111.96 37.233 KFactor 18.35 8 65.88 2.635 2T 16.474 165.000 34.599 KFactor= 11.20 to 120 32.948 0.0 9 65.88 0.0133 197.948 2.634 VeI= 3.876 9 111.96 6.357 2L 11.316 18.000 37.233 to 120 22.632 0.0 TOR 177.84 0.0012 40.632 0.047 Vel = 1.798 TOR 0.0 6.357 1A 33.948 30.000 37.280 to 120 1 12.573 95.557 12.993 HOSE 177.84 0.0011 1L 11.316 125.557 0.144 Vel = 1.798 iT 37.720 HOSE 100.00 6.357 0.100 50.417 Qa = 100 to 120 0.0 0.0 BOR 277.84 0.0 0.100 Vel = 2.809 .0 277.84 50.417 K Factor= 39.13 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A,~()~0114_ /-W tqco /Fire & Building I Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Customer Service/Sales: Tel: (414) 570-5000 / (800) 558-5236 Fax:(414) 570-5010/(800) 877-1295 Series EC-1 I & EC-14 - 112 and 14O K-factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Rec. Pendent Sprinklers General Description The Series EC-11 and EC-14 Ex- tended Coverage Upright and Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accord- ance with standard installation rules (e.g., NFPA 13) for a maximum cover- age area of 400 ft2 (37,2 m2), as com- pared to the maximum coverage area of 130 ft2 (12,1 m2) for standard cover- age sprinklers used in ordinary haz- ard occupancies or 225 ft2 (20,6 m2) for standard coverage sprinklers used in light hazard occupancies. The Series EC-11 and EC-14 Sprin- klers feature a UL and C-UL Listing that permits their use with unob- structed or non-combustible ob- structed ceiling construction as de- fined and permitted by NFPA 13, as well as a specific application listing for use under concrete tees. The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers have been fire tested to compare their per- formance to that of standard coverage spray sprinklers. These tests have shown that the protection provided is equal to or more effective than stand- ard coverage spray sprinklers. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Model/Sprinkler Identification Number TY5137 - Upright, 11.2K TY5237 - Pendent, 11.2K TY6137 - Upright, 14.0K TY6237 - Pendent,14.OK TY5137 is a redesignation for C5137, G1894, and S2510. TY5237 is a redesignation for C5237, G1893, and S2511. TY6137 is a redesignation for C6137, G1896, and S2610. TY6237 is a redesignation for C6237, G1895, and S2611. '3- - 4'Pln J 12.f /0_cf 4O•t 9ici Page 1 of 8 APRIL, 2003 TFP220 WRENCH 3/4" ** NPT 6* CROSS PENDENT SECTION 2-7/16" (61,9 mm) UPRIGHT & PENDENT 1/2(12,7mm) J NOMINAL MAKE-IN UPRIGHT ESCUTCHEON PLATE SEATING SURFACE / 1-11/16" (42,7 mm 1 - Frame 2 - Button 3- Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector" Temperature rating is indicated on deflector ** Pipe thread connections per ISO 7/1 can be provided on special request. Page 2 of 8 TFP22O FIGURE 1 SERIES EC-1 1 AND EC- 14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR (TY5137) UPRIGHT AND (TY5237) PENDENT 14.0 K-FACTOR (TY6137) UPRIGHT AND (TY6237) PENDENT SPRINKLER FINISH (See Note 4) HAZARD TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE" JPOLYESTER1 LEAD COATED LIGHT Refer to Table B for UL and C-UL Sensitivity Rating and Refer to Table C for FM Sensitivity Rating UPRIGHT K=11.2 (TY5137) PENDENT K=1 1.2 (TY5237) K14.0 (TY6237) 135°F/57°C Orange 1, 2, 3"" 1551F/681C Red 175°F/79°C Yellow 1,2 1,2 200°F/93°C Green 286°F/141°C Blue REC. PENDENT K=1 1.2 (TY5237) K=14.0 (TY6237) With Style 30 135°F/57°C Orange 1,2, 3 1,2 N/A 155°F/68°C Red 175°F/79°C Yellow Escutcheon 200°F/93°C Green 286°F/141°C Blue ORDINARY Refer to Table B for UL and C-UL Sensitivity Rating and Refer to Table C for FM Sensitivity Rating UPRIGHT K=11.2(TY5137) K=14.0 (TY6137) and PENDENT K11.2 (TY5237) K=14.0 (TY6237) 135°F/57°C Orange 1, 2, 3 1,2,3 1551F/681C Red 175"F179°C Yellow 1,2 200°F/93"C Green 286°F/141°C Blue REC. PENDENT K=1 1.2 (TY5237) K=14.0 (TY6237) With Style 40 Escutcheon 1350F/57°C Orange 1, .2 N/A 155"F/68°C Red 175°F/79°C Yellow 200°F/937C Green NOTES: 1 Listed by Underwriters Laboratories, Inc. (UL). 2.1-isted by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Where Polyester Coated or Load Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. "Frame and Deflector only. Listings and approvals apply to all colors (Special Order). ** Pendent Only. N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS TFP220 Page 3 of 8 LIGHT HAZARD ORDINARY HAZARD 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F AREA STYLE 14 x 14 Up. or Pend. - - - - - SR SR SR SR SR 14 x 14 Style 30 Recessed - - - - - N/A N/A N/A N/A N/A 14 x 14 Style 40 Recessed - - - - - SR SR SR SR N/A 16 x 16 Up. or Pend. OR OR OR OR OR SR SR SR SR SR 16 x 16 Style 30 Recessed OR OR OR OR OR N/A N/A N/A N/A N/A 16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR N/A 18x18 Up. orPend. OR OR OR. OR OR SR SR SR SR SR 18 x 18 Style 30 Recessed OR OR OR OR OR N/A N/A N/A N/A N/A 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR N/A 20 x 20 Up. or Pend. OR OR OR SR SR SR SR SR SR SR 20 x 20 Style 30 Recessed OR SR OR SR SR N/A N/A N/A N/A N/A 20 x 20 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR N/A OR: Quick Response SR: Standard Response N/A: Not Applicable TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-1 1 AND EC-14 SPRINKLERS LIGHT HAZARD ORDINARY HAZARD 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F AREA STYLE 14x14 Up. orPend. - - - - - SR SR SR SR SR 14 x 14 Style 30 Recessed - - - - - N/A N/A N/A N/A N/A 14 x 14 Style 40 Recessed - - - - - N/A N/A N/A N/A N/A 16 x 16 Up. or Pend. OR* QR' N/A N/A N/A SR SR SR SR SR 16 x 16 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 18 x 18 Up. or Pend. QR* QR* N/A N/A N/A SR SR SR SR SR 18 x 18 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 20 x 20 Up. or Pend. QR* QR* N/A N/A N/A SR SR SR SR SR 20 x 20 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 20 x 20 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A OR: Quick Response SR: Standard Response N/A: Not Applicable ° Pendent Only TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-1 1 AND EC-14 SPRINKLERS Page 4 of 8 TFP22O Technical Data Approvals UL and C-UL Listed. FM Approved. (Refer to Table A for complete approval information including corrosion resis- tant status. The approvals apply to the service conditions indicated in the De- sign Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficients K = 11.2 GPM/psill2 (161,3 LPM/bar1'2) K = 14.0 GPM/ps1112 (201,6 LPM/barll2) Temperature Ratings 135°F/57°C to 286°F/141°C Finish Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, and Brass Plated Physical Characteristics Frame .............Bronze Button .............Bronze Sealing Assembly .......... Beryllium Nickel w/Teflonf Bulb ........Glass (3 mm dia.) Compression Screw ......... ........Bronze Deflector ............Brass Patents U.S.A. Patent Numbers 5,366,022; 5,579,846; 5,584,344; 5,609,211; 5,862,994; and 5,865,256 are appli- cable to the Series EC-11 and EC14 Sprinklers. Other patents are pending with regard to other design features. Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprin- kler to activate and flow water. Design Criteria The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers must only be installed in accordance with the ap- plicable UL and C-UL Listing or FM Approval requirements as indicated below. Only the Style 30 or 40 Re- cessed Escutcheon is to be used for recessed installation, as applicable (Ref. Table A, B, and C). UL and C-UL Listing Requirements The Series EC-1 1 and EC-1 4 Sprin- klers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and hazard group for all of the sprinklers in the design area. With respect to heat sensitivity, the Series EC-il and EC-14 Sprinklers are permitted to be used with unob- structed or non-combustible ob- structed ceiling construction as de- fined and permitted by NFPA 13. For example: Unobstructed, combustible or non- combustible, ceiling construction with a deflector to ceiling/roof deck distance of 1 to 12 inches (25 to 300 mm). Obstructed, noncombustible, ceiling construction with a deflector location below structural members of 1 to 6 inches (25 to 150 mm) and a maxi- mum deflector to ceiling/roof deck distance of 22 inches (550 mm). The minimum allowable spacing be- tween the Series EC-1 1 and EC-1 4 Sprinklers, to prevent cold solder- ing, is 8 feet (2,4 m) for upright sprin- klers and 9 feet (2,7 m) for pendent sprinklers. The Series EC-11 and EC-14 Sprin- klers are to be installed in accord- ance with all other requirements of NFPA 13 for extended coverage up- right and pendent sprinklers. UL and C-UL Specific Application Listing Requirements For Installation Under Concrete Tees The Series EC-11 and EC-14 Ex- tended Coverage Upright Sprinklers (TY5137 & TY6137) have a UL and C-UL Specific Application Listing for use under concrete tees when in- stalled as follows: The stems of the concrete tee con- struction must spaced at less than 7.5 feet (2,3 m) on center but more than 3 feet (0,9 m) on center. The depth of the concrete tees must not exceed 30 inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m); however, where the concrete tee length ex- ceeds 32 feet (9,8 m), non-combus- tible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8 m) in length. The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4 mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (251,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler dis- charge criteria requirements of NFPA 13 for extended coverage up- right sprinklers applies. FM Approval Requirements The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers are to be installed in accordance with the appli- cable Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non-storage and/or non-flam- mable or combustible liquid) occupan- cies. Information provided in the FM Loss Prevention Data Sheets relate to, but are not limited to, hydraulic design, ceiling slope and obstructions, mini- mum and maximum allowable spac- ing, and deflector-to ceiling distance. Installation The Series EC-11 and EC-14 Sprin- klers must be installed in accordance with the following instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/141C temperature ratings. A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maxi- mum of 30 ft.lbs. (40.7 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must be installed with the deflector parallel to the mount- ing surface. Pendent sprinklers must be installed in the pendent position, TFP22O Page 5 of 8 2-7/8 DIA. 1/2±1/8 (73,0 mm) 1/2°(12,7mm) (12,7±3,2 mm) 2-1/4' DIA. 1/4(6,4 mm) FACE OF (57,2 mm) SPRINKLER FITTING (3,2 mm) MOUNTING MOUNTING SURFACE PLATE CLOSURE - 1-3/8" (34,9 mm) 1-1/8" (28,6 mm) FIGURE 2 SERIES EC-1 1 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) 3/4(19,1mm 2-1/4" DIA. 1/4(6,4mm) (57,2 mm) I 7) 1/8' - (3,2 mm) J1 MOUNTING PLATE 1-3/8" (34,9 mm) 7/8 (22,2 mm) FIGURE 3 SERIES EC-1 1 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON "FITTING SIDE" TOWARDS SPRINKLER FITTING / WRENCH RECESS (END "A") FIGURE 4 W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS ft :ç j WRENCH LUGS FIGURE 5 W-TYPE 4 RECESSED SPRINKLER WRENCH and upright sprinklers must be in- stalled in the upright position. Step 2. After installing the Style 30 or 40 mounting plate (or other escutch- eon, as applicable) over the sprinkler pipe threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten upright or pen- dent sprinklers using only the W-Type 3 (End A) Sprinkler Wrench. Wrench tighten the recessed pendent sprin- klers using only the W-Type 4 Sprinkler Wrench. The wrench recess of the ap- plicable sprinkler wrench (Ref. Figure 4 and 5) is to be applied to the sprinkler wrench flats (Ref. Figure 1). 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE Page 6of8 TFP220 GROUP I GROUP II LIGHT HAZARD ORDINARY HAZARD ORDINARY HAZARD 0.10 GPM/FT2 0.15 GPM/FT2 0.20 GPM/FT2 DESCRIPTION AREA GPM PSI GPM PSI GPM PSI TY5137 (K=1 1.2) UPRIGHT 14x14 - - 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 18x18 33 8.7 49 19.1 65 33.7 20x20 40 12.8 60 28.7 80 57.0 (K11.2PENDENT 14x14 - - 30 7.2 16x16 30 7.2 39 12.1 18x18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 57.0 TY6137 (K=14.0) UPRIGHT 14 x 14 N/A N/A - -, - - 16x16 N/A N/A 39 7.8 51 13.3 18x18 N/A N/A 49 12.3 65 21.6 20 x 20 N/A N/A 60 18.4 80 32.7 TY6237 (K=14.0) PENDENT 14 x 14 - - - - - - 16 x 16 37 7.0 39 7.8 51 13.3 18x18 37 7.0 49 12.3 65 21.6 20x20 40 8.2 60 18.4 80 32.7 1 ft. = 0.3048 m 1 ft2 = 0.093 m2 1 gpm = 3.785 1pm 1 psi = 0.06895 bar 1 gpm/ft2 = 40.74 mm/mm TABLED FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-1 1 AND EC-14 SPRINKLERS Care and Maintenance The Series EC-11 and EC-14 Sprin- klers must be maintained and serviced in accordance with the following in- structions: NOTE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection systems must be obtained from the proper authori- ties and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. TFP22O Page 7 of 8 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE, Ordering Procedure When placing an order, indicate the full product name. Please specify the Sprinkler Identification Number (SIN), quantity, and temperature rating. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (specify SIN), (specify K-Fac- tor), (specify temperature rating), (specify Pendent or Upright) Extended Coverage Sprinkler with (specify fin- ish), P/N (specify - from Table E, where applicable). Recessed Escutcheon: Specify: Style (specify 30 or 40) Re- cessed Escutcheon with (specify fin- ish), P/N (specify). Style 30 Recessed Escutcheon Chrome Plated............PSN 56-705-9-011 White Color Coated ........PSN 56-705-4-011 Brass Plated .............PSN 56-705-2-011 Style 40 Recessed Escutcheon Chrome Plated............PSN 56-700-9-010 White Color Coated ........PSN 56-700-4-010 Brass Plated .............PSN 56-700-2-010 Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 4 Recessed Sprinkler Wrench, P/N 56-875-4-001 P/N 51 - AAA - B -CCC AAA = 893 (for TY5237 K1 1.2 Pendent) AAA = 894 (for TY5137 Ki 1.2 Upright) AAA = 895 (for 1Y6237 K14.0 Pendent) AAA = 896 (for TY6137 K14.0 Upright) B = 1 (for Natural Brass) B = 4 (for White Polyester) B = 7 (for Lead Coated B = 9 (for Chrome Plated) CCC = 135 (for 135°F/57°C) CCC = 155 (for 155°F/68°C) CCC = 175 (for 1750F/790C) CCC = 200 (for 200°F/930C) CCC = 286 (for 286°F/1 41°C) TABLE E PART NUMBERS FOR EC-1 I AND EC-14 SPRINKLERS Page 8 of 8 TFP22O TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 i1- O2° AS oo i I4 Quick Response Extended Coverage Light Hazard Recessed Pendent and Pendent Sprinkler E,riSri'vq /7'EAP5r 9 2A`-9 Fz_ 51PA jC PS Zw' 4o pm le z;. ,? Ps No. 2-10.0 Old Cat. No. 3.12.0 Quick Response Large Orifice Extended Coverage Light Hazard Recessed Pendent and Pendent Glass Bulb Automatic Sprinkler Manufactured by: Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 ra hi Product Technical Description 11 Data The Central Model GB-20 OR Large Orifice Recessed Pendent and Pendent Automatic Sprinkler is a low cost, aesthetically pleasing unit, specifically designed for Extended Coverage/Light Hazard applications per NFPA 13 and 13R Standards. The Model GB-20 OR Sprinkler incorporates a specially designed deflector that provides a much greater area of coverage than most commercial sprinklers. A two (2) piece recessed escutcheon assembly that provides for 3/1 (9.5mm) of field adjustment is available. The Model GB-20 OR has a nominal K-factor of 7.8 (112.5 metric), a maximum temperature rating of 1550F/68°C, and a maximum working pressure of 175 psi(12.1 bar). The Model GB-20 OR is available in three standard finishes, chrome plated, factory brass and white painted. Its mating escutcheon plate is available in three standard finishes, chrome plated, brass plated and white painted with additional special painted finishes available. Operation: The glass bulb capsule operating mechanism contains a heat-sensitive liquid that expands upon application of heat. At the rated temperature, the frangible capsule ruptures, thereby releasing the orifice seal. The sprinkler then discharges water in a pre-designed spray pattern to control or extinguish the fire. For specific listing requirements, see the appropriate information contained in this brochure. Model: GB-20 OR Style: Recessed Pendent and Pendent Escutcheon: Model ELO Recessed (2-piece) Note: Only the Model ELO Recessed (2-piece) Escutcheon may be used. Substitution of other "recessed" escutcheons may impair the operating sensitivity and distribution pattern. Wrench: Combination Wrench or GB-20 Wrench Orifice Size: 17/3211 (13.5 mm) K-Factor: 7.8 (112.5 metric) Nominal Thread Size: 3/411 (20 mm) N.P.T. Temperature Rating: 1351F/570C 1 55°F/68°C Approvals: U.L., U.L.C., M.E.A. (312-92-E Vol II) Maximum Working Pressure: 175 psi (12.1 bar) Factory Hydro Test: 100% at 500 psi (34.5 bar) Standard Finishes: Sprinkler: chrome plated, brass Corrosion-Resistant Coatings: white, black, painted Escutcheon: chrome plated, brass, white painted Length: 2¼e" (52.4 mm) Width: 111/1611 (deflector diameter) Weight: 3.2 oz. (91 grams) Patent: Pending mhrtn Wrinrh Installation Diagram - GB-20 OR Recessed Pendent \ 2 1/4(57.2mm) Minimum Diameter I I I 2 3/4(69.9mm) Maximum I FACE OF REDU Diameter COUPLING SUPPORT CUP. GB-20 Wrench (Part #1125) FINISHED CEILING LINE ~-1 11/16(429mm) Diameter 3 1/4(82.6mm) Diameter Installation Diagram - GB-20 OR Pendent 'I I I FACE OF REDUCING COUPLING I I LfjI 1 11/16(429mm) I mm) Reference FXTh_\\\\\\_) - 11 1/I 6' (42.9mm) Diameter Note: Central's Model 65 or 401 escutcheon may be used. When using Central's Model 65 escutcheon, face of R.C. to protrude 1/a"(3.2mm) ±1/re"(I.6mm) below ceiling line. 2 Design Data Design Requirements Quick Response (3mm OR bulbs) Extended Coverage Light Hazard Applications Coverage Area Minimum Flow GPM(Lpm) Maximum Distance Off Wall Minimum Pressure PSI(bar) Style Temperature 16'x 16 (4.9mx4.9m) 26 (98.5) 8 feet (2.4 m) 11.1 (0.8) Pendent Recessed Pendent 1350F/570C 1550F/680C 135°F1570C 1550F/680C 18'x 18 (5.5 m 5.5 m) 33 (125.1) 9 feet (2.7 m) 17.9 (1.2) Pendent Recessed Pendent 1350F/570C 1550F/680C 1 35°F/57°C - - - - 20x20 (6.1 m 6.1 m) 40 (151.6) 10 feet (3.0 m) 26.3 (1.8) Pendent Recessed Pendent 1350F/570C __________ 135°F1570C - - - - ri Installation All Central Model GB-20 OR Recessed Pendent and Pendent Automatic Sprinklers must be in- stalled according to current NFPA 13 Standards and these installation instructions. Deviations from these requirements and standards or any alteration to the sprinkler itself will void any warranty made by Central Sprinkler Company. In addition, installation must also meet local government provisions, codes, and standards as applicable. The system piping must be properly sized to ensure the minimum required flow rate at the sprinkler. Check for the proper model, style, orifice size, and temperature rating prior to installation. Install sprinklers after the piping is in place to avoid mechanical damage; replace any damaged units. Wet pipe systems must be protected from freezing. Refer to the Installation section of Central Bulletins on the Model A-i Dry Pendent Sprinklers for use in dry pipe sprinkler installations. Upon completion of the installation, the system must be tested per recognized standards. In the event of a thread leak, remove the unit, apply new pipe joint compound or tape, and reinstall. Installation Sequence Step 1. The unit must be installed in the pendent position. Step 2. The face of the sprinkler fitting should be installed a nominal 9Ae" ± /16(14.3 mm ± 4.8 mm) behind the ceiling line as shown in the installation diagram on page two. Adjustments may be made via the push-on escutcheon plate to compensate for variations in the fitting. Do not use the push-on escutcheon plate to hold the unit in position. The sprinkler will function properly only when the system piping is anchored to the building structure. Otherwise reaction forces from system initiation could alter the sprinkler alignment and disrupt the pattern. Step 3. Use only a non-hardening pipe joint compound or Teflon* tape Apply only to the male threads. Step 4. Hand tighten the sprinkler into the fitting. Use a Central Combination Sprinkler Wrench for pendent sprinklers and a GB-20 Wrench for pendent or recessed pendent styles, to tighten the unit into the fitting. A leak-tight joint requires only 7 to 14 ft.-lbs.(9.5t0 19.0 Nm) of torque; a tangential force of 14 to 28 lbs.(62.3 to 124.5 N) delivered through a 6" (150 mm)handle will *Teflon is a trademark of the DuPont Corp. deliver adequate torque. Torque levels over 21 ft.-Ibs.(28.6 Nm) may distort the orifice seal, resulting in leakage Step 5. To install the escutcheon plate, align it with and press it over the sprinkler body until the outer edge of the escutcheon meets the mounting surface. CAUTION: Do not wrench or turn the deflector, as this action may damage the sprinkler and cause it to leak under pressure. Special care must be taken when installing with a CPVC system. Sprinklers must be installed after the CPVC manufacturer's recommended setting time for the primer and cement to ensure that neither accumulate within the sprinkler. Special care must be taken when installing with a copper system. Sprinklers must be installed only after the inside of the sprinkler drop and associated fittings have been wire brushed to remove any flux. Residual flux can cause corrosion and in extreme cases can impair proper sprinkler operation. Care & - J Maintenance Sprinklers must be handled care- fully. They must not be transported or stored where ambient temperature may exceed 1 00°F/380C. For best results, store them in a dry, cool location in the original shipping package. Do not install sprinklers that have been dropped or visibly damaged. Sprinklers must never be painted, coated, plated, or altered in any other way from manufactured condition or they may not function properly. Any sprinklers altered in such a manner must be replaced. The owner is responsible for the proper operating condition of all fire protection devices and accessories. The NFPA standard 25 entitled, "Inspection, Testing and Maintenance of Water-Based Fire Protection Systems", contains guidelines and minimum maintenance requirements. Furthermore, the local Authority Having Jurisdiction may have addi- tional regulations and requirements for maintenance, testing, and inspec- tion that must be obeyed. It is advisable to have sprinkler systems inspected regularly by a qualified inspection service. Length of time between such inspections can vary due to accessibility, ambient atmosphere, water supply, and site activity. Do not attempt to re-assemble or otherwise reuse a sprinkler that has operated. Replace any sprinkler exhibiting corrosion or damage; always use new sprinklers of the same type and temperature rating as replacements. Because the discharge pattern is critical to protection of life and property, nothing should be hung or attached to the sprinkler unit that ©1998 central Sprinkler Company Printed in U.S.A. would disrupt the pattern. Such obstructions must be removed. In the event that construction has altered the original configuration, additional sprinklers should be installed to maintain the protection level. Do not attempt to replace sprinklers without first removing the fire protec- tion system from service. Be certain to secure permission from all Authori- ties Having Jurisdiction, and notify all personnel who may be affected during system shutdown. A fire watch during maintenance periods is a recommended precaution. To remove the system from service mode, first refer to the system operating guide and valve instruc- tions. Drain water and relieve the pressure in the system piping. Remove the existing unit and install the replacement, using only the special sprinkler wrench. Be certain to match model, style, orifice, and temperature rating. A fire protection system that has been shut off after an activation should be returned to service immedi- ately. Inspect the entire system for damage and replace or repair as necessary. Sprinklers that did not operate but were subjected to corro- sive elements of combustion or excessive temperatures should be inspected, and replaced if need be. The Authority Having Jurisdiction will detail minimum replacement require- ments and regulations. Guarantee: Central Sprinkler Company will repair and/or replace any products found to be defective in material or workmanship within a period of one year from the date of shipment. Please refer to the current Price List for further details of the warranty. CENTRAL Central Sprinkler Company 451 North Cannon Avenue, Lansdale, PA 19446 PHONE (215) 362-0700 FAX (215) 362-5385 fl Ordering Information Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, model, style, orifice size, temperature rating, type of finish or coating, and sprinkler wrench. Availability and Service: Central sprinklers, valves, accessories, and other products are available through- out the U.S. and Canada, and internationally, through a network of Central Sprinkler distribution centers. You may write directly to Central Sprinkler Company, or call (215) 362- 0700 for the distributor nearest you. Conversion Table: 1 inch = 25.400 mm 1 foot = 0.3048 m 1 pound = 0.4536 kg 1 foot pound= 1.36 Nm 1 psi = 6.895 kpa = 0.0689 bar = 0.0703 kg/cm2 1 U.S. gallon = 3.785 dm = 3.785 liters Conversions are approximate. GB-20 QR.2