6400 SURFSIDE LN; ; FA110011
7/15/24, 2:24 PM FA110011 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FAIIOOII Job Address: 6400 SURFSIDE LN Status: ISSUED Permit Type: FALARM Applied 2/2/2011 Parcel No: 2140103811 Approved: 2/2/2011 Lot #: 0 Reference No.: Issued: 2/2/2011 PC #: Inspector: Project Title: SEAPOINT RESORT ELEVATOR TWO FIRE ALARM INSPECTIONS @, $65/EA Applicant: LOW VOLTAGE INTEGRATED SYSTEMS, INC. 2864 RANCHO GRANADERO CARLSBAD, CA 760-908-5883 Owner: WHITE MICHAEL T&KAREN C C/O CARLSBAD SEAPOINTE RESORT LP 5050 AVEN IDA ENCINAS #200 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 FIRE ALARM EQUIPMENT DA TA SHEETS L ADO VW.04*404, 30/rocs" I r t g r ci t S y $ t rn S FIRE ALARM 0 SOUND• DATA MEDIA 0 SECURITYO CCTV 0 ACCESS CONTROL PROJECT CARLSBAD SEAPOINT RESORT ELEVATOR #2 UPGRADE 6400 SIJRFSIDE LANE CARLSBAD, CA 92008 E CITY OF CARLSBAD FIRE DEPARTMENT APPROVED Subject to field i'lspecuofl and required tests, notations hereon, conditions. in correspondence and conformance with applicable regulations. the stamping of these plans shall not be held to permit or rove the violation 0f any ia M. Date / j LOW VOLTAGE INTEGRATED SYSTEMS, INC. 1930 WATSON WAY, STE C VISTA, CA 92081 (760) 598-4110 Phone (760) 598-4107 Fax lowvolta2e.sd()sbc2lobaI.net License:, CIO, C16 # 791832 fA~~ 06 ~ ~ Canadian DN-60600:A FireWarden-1 00-2C' Intelligent Addressable FACP 4. General The Notifier FireWarden-100-2C Rev 3 (NFW2-100C) with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Trans- mitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. The DCL (Signaling Line Circuit) of the FireWarden-100-2C operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an inci- dent and activate the notification circuits in under 10 seconds. With this improved polling, devices can be wired on standard twisted, unshielded wire up to a distance of 3,000 meters. The FireWarden-100-2C's quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is com- pleted, the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, additional secondary ANN-BUS, increased resettable power, and remote sync output. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polar- ity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PS-Tools Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows® XP or greater, a compatible modem, and PS-Tools, the Upload/ Download software kit, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other program- ming information. Version 5.0 firmware supports the following: ANN-bus devices, NP-A100, USB port, and NAC circuit diagnostics. A new report has been added to the walk-test that lists untested devices, Photo Supervisory and auto-resettable Drill (non-latching). Features ULC Listed. On-board DACT. Remote site or local USB port upload/download, using PS- Tools. Four Style Y (Class B) NAC circuits, which can be con- verted to four (4) Class A (Style Z) circuits with optional ZNAC-92 converter module. (Up to 6.0 amps total NAC power when using optional XRM-24B.) 010 NOTIFER® by Honeywell Selectable strobe synchronization for System Sesor, and Wheelock. Primar. and secondary ANN-BUS for connection to follow- ing opliDral mocules (cannot be used if ACS annurciators are used): - N-AN 1-80C Ramote LCD Annunciator - N-AN \1-l/O LE) Driver - N,-S/PG Printer Module - N-ANN-.RLY Relay Module - N-ANN-LED ?inunciator Module - N-ANN-FILED Annunciator Module alarms only ACS & Terminal-mode Annunciators: —ACS Annuncators: Up to 32 ACM Series anninciators (ACM-16AT or ACM-32 series). Cannot be used i ANN- BUS devices a-e used. - TermnaI-mode Annunciators: Up to 32 FDLI-80C annun- ciatos. EIA-232 printer/PC interface (variable baud rate) on main circuit board, fo jse with optional UL-listed printer PRN-6. Integral 80-character LCD display with backlighting. Real-tirre clockkalendar with automatic dayIght savings control. History tile with 11,000-event capacity. Maintenarce ale-t warns when smoke detector dust accu- mulatior is excessive. Automatic device type-code verification. One perscn aucible or silent walk test with walk-test log and printou:. Point trouble idertification. Watertlow (nonsilenceable) selection per monitor p.-int. DN-60600:A • 12/07/2010— Eage 1 of 4 System alarm verification selection per detector point. • 16-key alpha-numeric pad (similar to telephone keypad) PAS (Positive Alarm Sequence) and presignal delay per • 4 cursor keys point. • Enter NOTE: Only detectors may participate in PAS. DCL LOOP: Product Line Information DCL can be configured for NFPA Style 4, 6, or 7oin. FW2-100C: FireWarden-100-2C 198-point addressable Fire DCL supports up to 198 addressable devices per loop (99 Alarm Control Panel, one DCL loop. Includes 80-character detectors and 99 monitor, control, or relay modules). LCD display, single printed circuit board mounted on chassis, DCL loop maximum length 3,000 m. and cabinet. 120 VAC operation. See installation manual for wire tables. 4XTM Reverse Polarity Transmitter Module: Provides NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using output control modules (NC-100). The four Class B NACs can be converted to four Class A NACs with optional ZNAC- 92 converter module. Silence, Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 amps maximum per each NAC circuit. NOTE: Maximum 24VDC system power output is shared among all NAC circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (NFW2-1 OOC requires PS-Tools Programming software, available on VFWARDEN-CD and www.magni-fire.com). Upload/download system programming locally to the Fire- Warden-100-2C in less than one minute. USB programming with standard Male-A to Male-B cable. User interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Alarm Silenced (yellow) System Trouble (yellow) Maintenance/Presignal (yellow) Disabled (yellow) Battery Fault (yellow) Ground Fault (yellow) KEYPAD CONTROLS Acknowledge/Step Alarm Silence Drill System Reset (lamp test) Page 2 of 4— Canadian DN-60600:A • 12/07/2010 supervised output for local energy municipal box transmitter, alarm, and trouble. ZNAC-92: Optional converter module which converts four (4) Style Y (Class B) NAC circuits to four (4) Style Z (Class A) cir- cuits. VFWARDEN-CD: Contains PS-Tools Programming software for Windows®-based PC computer (cable not included). DP-9692B: Required dress panel for FireWarden-100-2C. TA-CE-B: Trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 26 AH batteries. NFS-LBB: Battery box, houses two 55 AH batteries. CHG-120: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional NFS- LBB for mounting. NOTE: CHG-120 required for batteries larger than I8AH. BAT Series: Batteries, see data sheet DN-6933. XRM-24B: Optional transformer. Increases system power out- put to 6.0 amps. PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download pro- gramming. PRN-6: UL listed compatible event printer. Uses tractor-fed paper. COMPA TIBLE ANNUNCIATORS N-ANN-80C: LCD Indicator is a remote LCD indicator that mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is black; order -W version for white; see DN-7114.) N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red or black enclosure (see DN-60242). N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242). N-ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. (See DN- 7107.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DN-7103.) N-ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DN-7105.) ACM-8R: Relay module provides 8 Form-C 5.0 amp relays. ACM Annunciator Series: LED-type fire annunciators capa- ble of providing up to 99 software zones of annunciation. Avail- able in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. FDU-80C (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the Fire Warden-100-2C, see the following data sheets (docu- ment numbers) ACM-8R (DN-3558), ACS/ACM Series (DN-0524), LDM Series (DN-0551), FDU-80C (DN-6820). COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI-i OOAA: Addressable low-profile ionization smoke detector. NP-i OOA: Addressable low-profile photoelectric smoke detec- tor. NP-i OOTA: Addressable low-profile photoelectric smoke detector with thermal sensor. NH-i OOA: Fast-response, low-profile heat detector. NH-i OORA: Fast-response, low-profile heat detector with rate- of-rise option. NH-iOOHA: Fixed high-temperature detector that activates at 190F/88C. NP-AllOOA: Addressable low-profile multi-sensor detector. ND-11 OOA: Photoelectric low-flow duct smoke detector. D355PLA: Innovair Fles low-flow non-relay duct-detector housing; includes NP-100A Photoelectric detector DNRA: Innovair Flex low-flow non-relay duct-detector housing. (Order NP-100A separately.) FireWarden-100-2C CV0 0. rj_~rjrj _1C 0 0 -J 0 0 LCD-8OFC 80-Character Backlit LCD Remote Fire NP-100A, NI-100A, Annunciator NP-100RA - l Photo Detectors SPSRVA - Series Speaker Strobe NP-AbOOA Addressable Multi-Sensor Detector NH-100A,Nft100RA, 1:1 P2RA Strobe Heat Detectors Power Supply NDM-100A Dual P2RA Strobe Monitor Module - P2RA Strobe NP-100TA Photo/Thermal J- .. NMM-100A Multi-Modules Monitor Module NC-100R-6A Six-Relay Control Module NC-100-6A Six-Circuit Supervised Control Module NZM-100-6A Six-Zone Interface Module - - NMM-100-10A Ten-Input Monitor Module NZM-1 OOA 2-Wire Detector Monitor Module HE -bOA, ND- lLA, DNRA DL i rtectors 0 NOT-BG1 2LX Addressable Manual Pull Station Canadian DN-60600:A • 12/07/2010 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits.......................................1 Addressable device capacity..........................................198 Programmable software zones.........................................99 ACS Annunciators ............................................................32 ANN-bus devices..............................................................16 Electrical Specifications AC Power: FireWarden-100-2 Rev 3: 120 VAC, 60 Hz, 3.0 amps. FireWarden-100-2 Rev 3(E): 240 VAC, 5 0 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery charger capacity: 7 AH - 18 AH batteries. Up to two 18 Ah batteries can be housed in the FACP cabinet. Larger batteries require an external battery charger such as the CHO- 75 or CHG-120, and a separate battery cabinet such as the BB-26 or NFS-LBB. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style Y (Class B) for a total of four Style Y (Class B) or with an optional ZNAC-92 module con- verts to four Style Z (Class A) NACs. Maximum signaling cur- rent per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Refer to panel documentation and Notifier Device Compatibility Docu- ment for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps © 30 VAC (resistive). Form-C relays. Special Application Non-resettable Power (24 VDC Nomi- nal): Jumper selectable (JP4) for conversion to resettable power output. Up to 1.0 amp total DC current available from each output. Power-limited. Special Application Resettable Power (24 VDC nominal): Jumper selectable (JP6) for conversion to non-resettable power. Up to 1.0 amp total DC current available. Refer to the Notifier Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 300 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a mini- mum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65 (42.29 cm.) wide x 5.20' (13.34 cm.) deep. Trim Ring (TA-CE-B): 22.00' (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F NFPA Standards The FireWarden-100-2 Rev 3 complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). - REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be con- nected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) - PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). - CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). - OT, PSDN (Other Technologies, Packet-switched Data Network) Agency Listings and Approvals The listings and approvals below apply to the basic FireWar- den-100-2 Rev 3 control panel. In some cases, certain mod- ules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635 FM approved CSFM: 7165-0028:0235 MEA: 120-06-E, Volume 2 For ULC-Iisted version, see DN-60600. NOTIFIER® is a registered trademark of Honeywell International Inc. Wheelock® is a registered trademark of and ExcederTM is a trademark of Cooper Notification. ©2010 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for __________________ This purposes. We try to keep our prod-dl • uct information up-to-date and accurate. We MIRNEERINS & MRNUF&C1UtlMG cannot coverall specific applications or anticipate QUALITY SYSTEMS all requirements. All specifications are subject to change without notice. Page 4 of 4—Canadian DN-60600:A • 12107/2010 For more information, contact Notifier. (888)289-1114 10 Whitmore Road Woodbridge, Ontario LZL 7Z4 www.notifier.com 38 NC.IOOR(A) dn-60 3:A2 OT F ER® Relay Module for FireWarden Series Panels by Honeywell General The NC-i OOR(A) Addressable Relay Module provides NOTI- FlER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- tact to be activated, either manually or through panel programming, on a select basis. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady when activated. High noise immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct Decade entry of address: 01 - 99 with the FireWar- den-100-2(C) and 01 —50 with the FireWarden-50(C). Applications The NC-100R(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The NC-iOOR(A) provides two Form-C dry contacts that switch together. Operation Each NC-1 OOR(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status. The LED blinks with each poll received. On command, it activates its internal relay. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identity the module to the con- trol panel. Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5' (11.43 cm) high x 4' (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125 (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Volthge Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R=5ms) Coded 30 VDC 0.5 A Inductive (L/R=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A dn-60353:A2 • 06/17/10 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. ULIULC Listed: S635. CSFM approved: file 7300-0028:230. FM approved. MEA approved: file 72-01-E, Vol. 2. Product Line Information NC-1 OOR: Intelligent addressable relay module. NC-i OORA: Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual, document 52304. NOTIFIER® is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. - This document is not intended to be used for installation purposes. I so 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING &MRNUFACTIIRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 - dn-60383:A2 • 06/17/10 DN-6998:B NP-Al OO(A)6 Addressable Multi Sensor Detector (IOT!FIER® For fireWarden Series Systems by Honeywell General The NP-Al 00(A) detector is an intelligent, addressable, multi- sensing, low-profile detector designed for use with FireWarden Series Fire Alarm Control Panels. The NP-Al 00(A) detector uses a combination of photoelectric and thermal sensing technologies to increase immunity to false alarms. Unlike traditional intelligent detectors, the NP- A100(A) detector has a microprocessor in the detector head that processes alarm data. As a result, the NP-A100(A) detec- tor adjusts its sensitivity automatically, without operator inter- vention or control panel programming. Areas where the NP-A100(A) detector is especially useful include office complexes, schools, college campuses, manu- facturing and industrial facilities, and anywhere else the use of a particular area may change. The NP-A100(A) detector auto- matically adjusts its sensitivity to the environment. Features Automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. Microprocessor-based, combination photo and thermal technology. Addressable-analog communication. Sleek, low-profile design. Two-wire SLC connection. Direct-Dial entry of address: 01-99 with FireWarden-100-2 and 01-50 with FireWarden-50. Addresses can be viewed and changed without electronic programmers. Dual bi-color LED design provides 360° viewing angle. Built-in tamper-resistant feature. Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. SEMS screws for wiring of the separate base. Several base options, including relay, isolator, and sounder. Built-in functional test switch activated by external magnet. Listed to UL 268. Specifications Size: 2.0" (5.3 cm) high x 4.1" (10.4 cm) diameter installed in B501 base, 6.1" (15.5 cm) diameter installed in B71OLP base. Shipping weight: 5.2 oz. (147 g). Operating temperature: 0°C to 38°C (32°F to 100°F). Operating altitude: up to 10,000 feet. UL-Listed velocity range: 0 - 4000 ft/mm. (1219.2 m/min.), suitable for installation in ducts. Relative humidity: 10% - 93% noncondensing. Thermal sensing rating: fixed-temperature setpoint 135°F (57°C). 6937ph01 NP-A100(A) in B7IOLP base ELECTRICAL SPECIFICATIONS: Voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 300 pA. Loop resistance: 50 ohms maximum; varies according to control panel used. Refer to panel installation manuals. LED current (max.): 6.5 mA @ 24 VDC ("ON"). Installation The NP-A100(A) plug-in detector uses a separate base to sim- plify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove detec- tors without using a ladder. Suitable mounting base boxes include: 4.0" (10.16 cm) square box. 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box Single-gang box (except relay or isolator base). NOTE: The NP-A 100(A) detector has the unique ability to adjust sensitivity according to the environment, based on heat and smoke levels. Avoid installing these detectors in locations that are susceptible to rapid and high temperature changes. An example of an incorrect application would be near or in line with the output of a self-contained heater. Agency Listings and Approvals These listings and approvals apply to the modules specified in this. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. ULListed:51115 liLCListed:51115 FM Approved CSFM: 7272-0028:0258 DN-6998:13• 10/2612010—Page 1 of 2 Ordering Information NOTE: "A" suffix indicates ULC Listed mode!. NP-A100: Low-profile intelligent multi-sensor detector. B710LP base included. NP-A100A: Same as but with ULC Listing. B710LPA base included. INTELLIGENT BASES B501(A): Flangeless mounting base. B200SR: Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces the B501 BH series bases in retrofit applications. B71OLP: Flanged mounting base. (6.1", 15.5 cm diameter) B710LPA: Flanged mounting base, ULC Listed. B224RB: Relay base Screw terminals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A © 30 VDC inductive. Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm).. B224RBA: Relay base, ULC Listed. B224B1: Isolator base. Dimensions: 6.2" (15.748 cm) x 1.2' (3.048 cm). Maximum: 25 devices between isolator bases. B224B1A: Isolator base, ULC Listed. ACCESSORIES: Fl 10: Retrofit replacement flange for older high profile bases. Converts bases for use with detectors. RA1 OOZ: Remote LED annunciator. 3-32 VDC. Fits U.S. sin- gle-gang electrical box. Supported by B71OLP(A) and B501 (A) bases only. SMB600: Surface mounting kit for use with B71OLP(A). BCK-200B: Black detector covers, box of 10. M02-04-00: Test magnet. M02-09-00: Test magnet with telescope stick. XR2B: Detector removal tool. Allows installation and/or removal of Series detector heads from base in high ceiling installations. T55-127-010: Detector removal tool without pole. X13-4: Extension pole for XR2B. Comes in three 5-ft. sections. Notifier® is a registered trademark of Honeywell International Inc. 02010. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 101111112-1-9 I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ffdUNElNI a M11ACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6998:13 • 10/26/2010 Fig. 1 MODEL 302 For interior mounting in any atmosphere that is compat- ible with terminal screw type connections. Fig. SAP-P Decorative white plastic adapter plate for mounting 302, 302-AW and 302-El detectors L, ) only. iiiiii;1nrE!;ifl MODEL DESCRIPTION REFER TO: 302-135 135°F - Interior Vertical Mounting FM & UL Fig. 1 302-194 194°F - Interior Vertical Mounting FM & UL 302-ET-1 35 135°F - All Weather Vertical Mounting FM & UI. Fig. 2 302-ET-194 j.94-All Weather Vertical Mounting FM & UL 302-AW-1 3P 'I°F - All Weather Vertical Mounting FM & UL Fig.3 302-AW-1 94 194°F - All Weather Vertical Mounting FM & UL 302-EPM-135 135°F- Explosion Proof Mounting UL Fig. 4 302-EPM-1 94 194°F - Explosion Proof Mounting UL AP-P Decorative white plastic adapter plate for mounting 302, 302FF Fig. 5 and 302AW to any 3" outlet box or 4" octagon outlet box. Fig. 2 MODEL 302-El Hermetically sealed for moisture proof or dust proof installations. Requires no special back box. Has plastic hexago- nal grip bushing with 1/2" conduit f threads for attachment to threaded hub cover, or any outlet box. Must be hand tightened only. For <T - inrinnr nnrl niitrinnr use. Protect from direct sunlight and adverse weather conditions. II Fig. 4 MODEL 302-EPM / Explosion proof for installation in hazardous locations. Has hexagonal grip bushing with 1/2' conduit threads for attach- // ment to threaded hub cover of series JL fixture fitting as manu- factured by Killark Electric Co., or equal. Must be hand tightened only. For Interior use. Fig. 3 MODEL 302-AW Hermetically sealed for moisture proof or dust proof installations. Requires no special back box. For indoor and outdoor use. Protect from direct sunlight and adverse weather conditions. Each model is a normally open device designed especially for fire detection and alarm systems. These rate compensation type detectors are available in either 1350 E or 194° F. ratings. All four basic models are self restoring, hermetically sealed, shock and corrosion resistant, and are tamper proof. Refer to NFPA STANDARD 72, STANDARD FOR AUTOMATIC FIRE DETECTORS for application requirements, testing and maintenance. (actual size) All models operate on the principles of a rate compensation detec- tor. The detector consists of a high expansion aluminum tube which encases two insulation struts with opposing open constant points (see cut-away view). The high expansion sensing shell and the expan- sion struts have a different coefficient of expansion. A slow rate of temperature rise allows the heat to penetrate the inner expansion struts. Therefore, the tubular shell and the struts expand slowly until the total device has been heated to its rated temperature level of 135° F/i 94°F. At this point, the silver contact points close which initiates the alarm. When subjected to a rapid rate temperature rise there is not as much time for heat to penetrate the inner strut. The rapid lengthening of the shell allows the struts to come together at a lower level which compensates for thermal lag inherent in conventional fixed temperature detectors. When the surrounding air temperatures goes below the rated temperature level, the shell contracts which forces contacts to open, thus automatically resetting the detector. liver contact points sion struts xpansion sensing 040 anodized ontrol sleeve g screw hermetic seal Dimensions (Model 302): Total overall length 4 1/8' Base Diameter: 2'. Temp. Rating OF. Max Ceiling Temp. °F. 135 115 194 155 iJs1i.1TLSiffiI1I i!! SgnaIinn Detectors are not directionally effected, can be mounted horizontally Underwriters' Laboratories or vertically. Detectors have a smooth ceiling UL rating of 50' x 50' (2500 sq. ft.) on 8 to 10 ft. ceilings. Detectors, hub covers, or outlet Lsted boxes must never be installed in direct sunlight. Refer to NFPA STAN- DARD 72 for spacing and other considerations. For further information refer to www.thermotechheatdetectors.com ApprOved Electrical Rating (j California State Fire Marshall. Listing No. 7270-0021:001 Voltage Current 6-125 VAC 5 amps MEA Acceptance # 193-03-E 6-25 VAC 1 amp 125 VDC 0.5 amp Monitor Modules DN-6999:C NMM-1 00(A), NMM-1 00P(A$" OTEFER® NM-1001A). and NDM.IOOIA) for FireWarden Series Panels by Honeywell General Four different monitor modules are available for Notifier's Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (NZM-1 00(A)). NMM-100(A) is a standard-sized module (typically mounts to a 4 [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-100P(A) is a miniature monitor module a mere 1.3' (3.302 cm) H x 2.75 (6.985 cm) W x 0.5 (1.270 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. NMM-100(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade entry of address: 01 - 99 on FireWarden- 100-2, 01 - 50 on Fire Warden-50. LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. NMM-100(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, watertlow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. NM M-1 00(A) (Type H) NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 1.25 (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6999C.10/06/2010—Page 1 of 4 NMM-IOOP(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct Decade entry of address: 01 - 99 on FireWarden- 100-2, 01 —50 on Fire Warden-50. 1415 0 1 ADDRESS 0 12( 13' (\3 P LOOP TENS ONES II o LU 0 0 Uj —J ri The NMM-100P(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. NMM-100P(A) NMM-100P(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. NMM-100P(A) OPERATION Each NMM-100P(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). NMM-100P(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75° (6.985 cm) wide x 0.65 (1.651 cm) deep. Wire length: 6' (15.24 cm) minimum. NZM-100(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade entry of address:, 01 - 99 on FireWarden- 100-2, 01 - 50 on FireWarden-50. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The NZM-100(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. NZM-100(A) OPERATION Each NZM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Page 2 of 4— DN-6999:C • 10/06/2010 NDM.100(A) Dual Monitor Module The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The NDM-100(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style 0 (Class A) IDC circuits are NOT supported in any application. NDM-100(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 2.125' (5.398 cm) deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the NDM-lOO(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol. 3 (NDM-100) Product Line Information NOTE: "A" suffix indicates ULC-listed model. NMM-100(A): Monitor module. NMM-100P(A): Monitor module, miniature. NZM-100(A): Monitor module, two-wire detectors. NDM-100(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN52304. CAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4' (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMBSOO surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S635 FM Approved CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100); 7300-0028:0237 (NDM-100) DN-6999:C • 10/06/2010 - Page 3 of 4 Notifier® and FireWarden® are registered trademarks and FireWatch is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. - I SO 9001 --:= - - This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. ENSINEM111 & MMUFflC1IINC QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-6999:C • 10/06/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7165-0028:0235 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NOTIFIEROne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models Fire Warden 100 and *Fire Warden 100-2 addressable control units. Local, auxiliary, remote station, central station and proprietary (protected premise). This panel also can be used with NFV-25/50ZST (Fire Voice-25/-50ZST) Zoned System Voice with Telephone for Emergency Voice evacuation Applications. Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. XLF: 7165-0075:0208 *Rev. 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed '\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING- BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0230 Page 1 of 1 CATEGORY: 7300--MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: NOTIFIEROne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-1 00 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 10-20-04 , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an -,s endorsement or recommendation of the item listed. This listing should not be used to verify correct operational cfr requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:0231 Page 1 of 1 CATEGORY: 7272 -- PHOTOELECTRIC SMOKE DETECTOR LISTEE: NQTlFlEROne Fire-Lite Place, Northford, CT 06472-1653 Ctct: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 E?9ladimir.kireyev@honeywell.com DESIGN: MOdels'JP-100, NP100R* and NP-100T photoelectric type smoke detectors. Model NP-1 OOT has a 135F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0 -4000 FPM. *Models NP-100 and NP-IOOR are also approved for installations inside Notifier duct detector housing ND-200 (OSFM Listing No. 3242-0028:236) and System Sensor duct detector housing DNRW (OSFM Listing No. 3242-1653:210). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0075:0194 *Rev. 01-27-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an \J/ endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7270-0021:0001 . Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: Thermotech Inc.,2900 North 1000 West, Ogden, UT 84414 Contact: Sherman Barker (8042-2233 Fax (801) 782-1746 Email: thermotechinc@hoy DESIGN: Models 302, 302H, 302A'. 302E1 and 302EPM heat detectors. Units are open circuit, 1350 F, 1940 F fixed temperature and rate-of-rise type heat detectors. Models 302 and 302-H are for indoor use. Models 302-El or 302-AW are for all weather use. Model 302-EPM is suitable for use in Class I, Groups C and D and Class II, Groups E, F and G hazardous locations. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 6-125 VAC or VDC, 125 VDC 1350 F, 1940 F fixed temperature and rate-of-rise INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models 302, 302-El and 302-AW are for intended for vertical mount and Models 302-H is intended for horizontal mount only. MARKING: Listees name, model number, electrical and temperature rating and UL label. APPROVAL: Listed as fixed temperature and rate of rise type heat detectors for use with separately listed compatible fire alarm control units. *Rev. 05-01-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an -/ endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0230 Page 1 of 1 CATEGORY: 7300--MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: NOTIFIEROne Fire-Lite Place, Northford, CT 06472-1653 Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 ErriaNadimir.kireyevhoneywelI.com DESIGN: Modelsl"IMM-lOOP, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 10-20-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Parsley Consulting 350 West 9k Avenue, Suite 206 Escondido, California 92025-5053 Telephone (760) 745-6181 Fax(760) 7450537 January 28, 2011 Mr. James Weigand City of Carlsbad Fire Department Office of Fire Protection Services 1635 Faraday Avenue Carlsbad, California 92008 Subject: Plan Review for Seapoint Resort Elevator Upgrad, 6400 Surfside Lane, Carlsbad, California Dear Mr Weigand: We have reviewed the submittal as prepared by Low Voltage Systems. Based on our review it is our opinion that the submittal is in substantial conformance with the applicable codes and standards in force at this time, including local adopted ordinances. Further submittal should not be required. We had no comments. Sincerely, Xenneth EY OULTNG W. WagoneT Office Manager End (1) Working Drawings - 2 sets (2) Material Submittals - 2 sets Note: A copy of this letter has been transmitted via fax to Low Voltage Systems on January 28, 2011 fi!e:\C:\Docurnents and Settings\Ken\Rev2111I3.001wpd