Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6455 SURFSIDE LN; ; AS110089
7/15/24, 2:09 PM AS 110089 Permit Data City of Carlsbad Sprinkler Permit Job Address: 6455 SURFSIDE LN Permit Type: SPRINK Parcel No: 2140210100 Lot #: 0 Permit No: AS110089 Status: ISSUED Applied 6/9/2011 Approved: 6/9/2011 Reference No.: Issued: 6/9/2011 PC #: Inspector: Project Title: DUTTA RESIDENCE RES. FIRE SPRINKLER PLAN CHECK & 3 INSPECTIONS Applicant: WESTERN STATES FIRE PROTECTION 3720 INDUSTRY AV STE 107 LAKEWOOD, CA 90712 562-279-0770 Owner: DUTTA FAMILY TRUST 07-07-97 7819 VISTA LAZANJA SAN DIEGO CA Fees ($) Add Fees ($) LTotal $ Balance ($) 260 0 260 0 about:blank 1/1 0, 108.0 -o-a2L._' &QQ4,9Q,1 inn in: 9Q 96 j, 5.2 .2Q00, 91.6 50, 7.6 00,83.2 3000, 500 1000 1500 2000 2500 3000 Flow (GPM) 120.0 0.0 0 8.4 '3.3 100.0 80.0 40.0 20.0 Millennium Fire Protection Cor Date of Test: 7/12/2011 Time of Test: 9:51 AM Elevation: 63' ASL Project: Iron Town Homes Preformed by: J.Forsyth, J.Balch (-i Test Address: 6455 Surfside Lane, Carlsbad, CA Witness by: Carlsbad Water Dept. 0 Static Residual Pilot Outlet Dia. Outlet Coff. 108 PSI 100 PSI Flow at Residual 80 PSI Flow at 20 PSI 2.5 IN Flow at 0 PSI 0.815 1357.7 GPM 4956.2 GPM 5535.8 GPM Used for Residual Flow Used for Pressure at specific Flow Q=29.8 x c x d12 x Ov Qf=QF x (hrA0.54 I hfA0.54) hr((Qf x hfA0.54)/QF)A1 .85 Q= Flow Qf= Flow (at desired pressure) c= Outlet Coff. QF= Flow Observed (Flow @ Residual) d= Outlet Dia. hr= Desired A Pressure (Static - Desired Pressure i.e 20 psi, 0 psi). Pv= Pitot hf= Observed A Pressure (Static - Residual) 4 101 Copperwood Way, Ste H Oceanside, CA 92058 • Phone (760) 722-2722 • Fax (760) 72?-2730• License# C16-869040 CITY OF CARLSBAD FIRE DEPARTMENT APPROVED Subject to field inspection and required tests, notations hereon, conditions in correspondence and conformance with applicable regulations. The stamping of thes,pIanjgshall not be held to permit or a violation of any law. By Si_ Date______ RIP An jobN— DUTTA RESIDENCE FAX 916-924-1631 916-927-1637 i 5 SURFSIDE LANE StatGG&t5-&floWLiws9Numbw CARLSBAD, CA 92011 CARLSBAD FIRE DEPT. RESIDENCE r 101mil. MINES WE A. of AppkaWn 4.9 K-Factor 17.00 at 12.037 I DUTTA 32.978 34.05 4i6L'I'X1VL ON 717 writ RE 1.71U, NOR — 0.00 0.000 0.000 iiil IIf4 T iiuii•___________ III". • Ill_u________ ill_u________ uIIIIIIIIIuuUUIIIIuIIIuIIIuuIIIIIIUUUUU S S. S SI S •• S 5• © M.E.P.CAD, Inc. A AutoSPRINK® VR8 v8. 1.11 05/13/2011 3:13:08PM Page 1 Job Number: RH1028 -2 HEAD DEMMAND CALC Report Description: Residential Job NtiThbI RH1028 NICK CLUTTS Job Name: StateCeosieNambar DUTTA RESIDENCE Addresat AfU 6455 SURFSIDE LANE CARLSBAD FIRE DEPT. Akbeos 2 Job SS8UttuIg CARLSBAD, CA 92011 DUTTA RESIDENCE AdSs 3 DrimingNarne SUBMITTAL SHEET.cad Moat O.mandtng aidoaDoto Occupancy Job8iillbc 4.9 K-Factor 17.00 at 12.037 Residential 2 HEAD DEMMAND CALC HooaMowaficeAl SoWce ooal4ty dma olApptcotice 0.00 0.1oogpm/ft2 900.00ft2 (Actual 120.51ft2) NcetherOfSp,àolamCatcalatod CoaeesePar Sp,iHoar Me Flow(aom) 2 324.00ft2 MthPe.k Resulta Pressure For Ramoto Area(*) Macent TO Most Fnanotekos Total Have SO,eams 0.00 System Awooasuod Total 00Mm Requbed(loobsdng Hose Allowance) 34.05 34.05 Mealosee Prow" Unbalance In Loop 0.000 7.30 between nodes 106 and 102 Masbinton Ydacly (iodsr000uod VoocspooltyotWd PVe$ Vobosecopacfty orD.y ApOS 40.56ga1 Hose Flow Static Residual Flow Available @ Total Demand (psi) (gpm) Required Safety Margin Node (psi) (psi) (Qpm) (psi) (psi) 1 0.000 0.000 0.00 0.000 34.05 32.978 -32.978 o. CortractorHombee ConboatNamo Cobol 15. C-16 488359 NICK CLUTTS Project Manager Name of Contredor Pbofle E5m$lOO Western States Fire Portection Company (916) 924-1631 121 "1100,.lI ............ Mdress I FAX 4740 Northgate Blvd. Ste #150 (916) 924-1637 2 r7a E.maf nichoIas.cIuttswsfp.us wol,.6 ramento, Ca 95834 www.wsfp.com , 0 M.E.P.CAD. Inc. 40 AutoSPRINK® VR8 v8.1.11 05/13/2011 3:13:13PM Page 2 , 0 M.E.P.CAD, Inc. AutoSPRINK® VR8 v8.1 .11 05/13/2011 3:13:17PM Page 3 Job Number RH1028 -2 HEAD DEMMAND CALC Report Description: Residential Node Elevation( Foot) Fittings Pressure(psi) Discharqe(gpm' 34.0 1 -1-1Y2 S - 32.978 101 20-7 pr(-12.037) 12.037 17.01 103 20-7 Spr(-12.114) 12.114 170 42 20-10% T(5'-O), Tr(1'-O) 12.738 102 10'-1A 26.342 104 0-10% 31.477 106 10'-VA E(3'-O) , © M.E.P.CAD, Inc. iffi AutoSPRINK® VR8 v8. 1.11 05/13/2011 3:13:21 PM Page 4 ReportIn-___________________ Job Number: RH1028-2HEADDEMMANDCALC Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary Go ..... Route l ..... DR 1.1010 17.00 5.73 150 0.050373 0.819 101 42 20-7 20-10% 17.00 4.9 12.037 12.738 Sprinkler, E(5'-O), Tr(1'-O) IMP e -0.117 v FM 1.3940 34.05 7.16 150 0.057721 97'-1Y Pf 8.952 42 102 20'-10% 10-1% 12.738 26.342 5E(6'-O), 10Tr(1'-O), 3T(6'-O) 58- 155'-IY Ps 4.651 Pv BL 1.3800 34.05 7.30 120 0.091615 0- Pt 0.336 102 106 101-1% 101-1% 26.342 26.678 E(3'-O) 3'- 3'- Pe Pv BL 1.6100 3405 5.37 120 0.043245 9'- Pt 0.789 106 _104 10'-1Y2 0-10% 26.678 31.477 CV(9'-O) 9'- 181- Pe 4.010 Pv BL 1.3940 34.05 7.16 150 0.057721 4'-11 Pt 0.634 104 0'-10% -1'-l% 31.477 32.978 Supply, E(6'-O), S 6' 1 01_1 134 Ps 0.867 Pv 0.00 Hose Allowance At Source 34.05 •• Route 2 •• • DR 1.1010 17.05 5.75 150 0.050673 4714pf 0.741 103 42 20'-7 29-10Y4 17.05 4.9 12.114 12.738 Sprinkler, E(5'-O), T(5'-O) 1 0'-q 14'77 Pe -0.117 Pv ( Actual Inside Diameter \487 - 's Schedule 40 Steel Pipe Inside Diameter / - Factor Value Of C 100 130 140 Multiplying Factor 0.713 1.16 1.33 150 1.51 f,©M.E.P.CAD, Inc. AutoSPRlNK®VR8v8.1.11 05/13/2011 3:13:25PM Pace 5 Job Number: RH1028 -2 HEAD DEMMAND CALC Report Description: Residential Downstream Elevation Discharge K-Factor Pt Pn - Fittings I Eq. Length I Summary AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gp b Bushing ON Drain Discharge gpm BalV Ball Valve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure ) BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 900 FR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen-Williams Constant Cr Cross Run OR Outrigger pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DeW Deluge Valve SP Sprig RI Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe Re Pressure due to elevation difference between indicated points E 90° Elbow UG Underground Pv Velocity pressure at a point in a pipe EE 450 Elbow Eel 11W Elbow Ee2 22%° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 900 FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node IT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LIE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PD Pipe Outlet PRV Pressure Reducing Valve RN Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WPW Water Meter Valve Z Cap .©M.EP.CAD. Inc. 4,3 jAutoSPRINKttVR8v8.l.1l 05/13/2011 3:13:25PM Page Job Number: RH1028 -2 HEAD DEMMAND CALC Reoort DescdDtiorc Residential Supply at Node I 50- 45 - 40- 35 30 0. - 25 w 0. 20- 15- 10- 5- 0— i11!L.LLLL.LJ.L 1 lI(I(1 Littiltil ILIlIIII Ittlilill (II I ( IJI II 0 5 100 150 200 250 300 350 400 150 500 Water flow, gpm NydrnócGt, Supply at Node 1 stsfic Pwge 0.000 Rs,idu* P,i.w. 0.000 @ 0.00 A.M" .f - 0.000 © 34.05 32.978 © 34.05 $te,o Deo..d I'nr.g H000wwceotSome) 32.978 @ 34.05 , © M.E.P.CAD, Inc. AutoSPRINK® VR8 v8.1 .11 05/13/2011 3:13:30PM Page 7 I,'M.E.P.CAD, Inc. III AutoSPRINK®VR8 v8.1.11 05/13/2011 3:13:34PM Page 8 Ok AWMT Job Number: RH1028-2 HEAD DEMAND CALC :V . .1• Job Number RH1028 Design Eng.uaa NICK CLUTTS Job Name. DU1TA RESIDENCE Phone 916-924-1631 FAX 916-927-1637 Address 1 6455 SURFSIDE LANE Stale CedhflcatloniLica.rsoldmnber Address 2 AJIJ CARLSBAD, CA 92011 CARLSBAD FIRE DEPT. Address 3 Job Site/Budding DUTFA RESIDENCE c- ___________________________________ -. Density 0.100gpm/ft2 kes otApplicohon 900.00ff2 (Actual 120.51ff2) Most Demanding Sprinkier Data 4.9 K-Factor 17.00 at 12.037 Hose streeflrs 0.00 Coverage Per Sprinkler 324.00ft2 Number Of Sprinsters Calculated 2 System Pressure Demand 32.978 System Flow Deenarrd 34.05 Total Demand 34.05 @ 32.978 Pressure Oenog -32.978 (-100.0%) I ptrit Gug Identifier Pressure(psi K-Factor(K) Flow(crnml Node Elow(aom) Hose Flow(aom Static(psi) Residual(osi) 1 0.00 0.000 0.000 .. p o : ... 10-1 Ito% 50- B. B B - •'—B 45 • 40 35 TF7 30 UFFT 1 __ CL 2 - 0 20- - 15 25- - - - o .it III] 96'0150 '00 250 300 350 400 450 500 Water flow, gpm © M.E.P.CAD, Inc. 4.11 AutoSPRINK® VR8 v8. 1.11 05/13/2011 3:13:08PM Page 1 Summaty Job Number RH1028 2 HEAD DEMMAND CALC Report Description: Residential °- it 0 Job Number RH1028 Design Engineer NICK CLUTTS Job Name: StaaCartlttcetonJuceaneloumbm DUTTA RESIDENCE Addresn I AAU 6455 SURFSIDE LANE CARLSBAD FIRE DEPT. Mittens 2 CARLSBAD, CA 92011 Job Sitelanildiog DUTTA RESIDENCE AddtOnn 3 Dreraing Nerve SUBMITTAL SHEET.cad fiêñbtOAa(s) Most Demanding Sprinkler Data Occupancy Jobs ffb( 4.9 K-Factor 17.00 at 12.037 Residential 2 HEAD DEMMAND CALC Hose AliowareeAtSoutce Sorrily AAoantAppllcetlon 0.00 0.1oOgpm/ft2 900.00ft° (Actual 120.51 ft2) Additional 1-1000 Soppion Number Of Spnnldaro Calculated Coverage Par Sprinkler Node Flow(porn) 2 324.00ft2 ActoPeak Ranolto. Prancer. For Remote Area(s) Adjacent To Most Remote A,ao Total 1-lose Streams 0.00 System Flow Damned Total Weter Required (Including Hose Allowance) 34.05 34.05 Maromum Pressure Unbalance In Loops 0.000 Macboone Velocity Above Ground 7.30 between nodes 106 and 102 Mactenum Velocity Under Ground Volume capacity of Wet Pipes Vol .ursa capacity ntDry Pipos 40.56ga1 - . . . Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node (gpm) (psi) (psi) (gpm) (psi) (gpm) (psi) (psi) 1 0.000 0.000 I 0.00 0.000 34.05 32.978 1 -32.978 ContraclorNumber C-16 488359 - Contact Nerve NICK CLUTTS Contact Tilta Project Manager Name at Contractor Phone Ectoosion Western States Fire Portection Company (916) 924-1631 121 Address I FAX 4740 Northgate Blvd. Ste #150 (916) 924-1637 Address 2 5 mail nicholas.clutts@wsfp.us Address 3 Web-Site Sacramento, Ca 95834 www.wsfp.com , © M.E.P.CAD, Inc. 11 AutoSPRINK® VR8 v8. 1.11 05/13/2011 3:13:13PM Page 2 - Job Number: RH1028 -2 HEAD DEMMAND CALC 0 M.E.P.CAD Inc. AutoSPRINK® VR8 v8. 111 05/13/2011 3:13:17PM Page 3 I Job Number: RH1028 -2 HEAD DEMMAND CALC Renort Descriotion: Residential Node I_Elevation(Foot) Fittings Pressure(psi) Discharge(gpm 1 .1.11/2 S 32.978 34.0 101 20'-7 Spr(-12.037) 12.037 17.0 103 20-7 Spr(.12.114) 12.114 17.0 ,1 42 20-1Y4 T(5-O), Tr(1'.0) 12.738 102 1O'-1Y 26.342 104 0-1OYz 31.477 106 10-1Y2 E(3-0) 26.678 13, © M.E.P.CAD, Inc. A 11 AutoSPRINKl5 VR8 v8. 1.11 05/13/2011 3:13:21 PM Page 4 Friction Pn Fittings 12.037 12.738 Sprinkler, E(5'-O), Tr(1'-0) 150 0.057721 12.738 26.342 5E(6'-O), 10Tr(1' 120 0.091615 26.342 26.678 E(3'-0) 120 0.043245 26.678 31.477 CV(9-0) 150 0.057721 31.477 32.978 Supply, E(6-0). S Length Pressure Eq. Length Summary Total Length 10'- Pt 0.819 6'-' Pe -0.117 16'- Pv 97'-1Y Pt 8.952 58-i Pe 4.651 155'-V/ Pv 0'- Pt 0.336 3-I Pe 3-1 Pv 9- Pt 0.789 9-I Pe 4.010 18'- Pv 4-11, Pt 0.634 6-I Pe 0.867 10'-11/ Pv Job Number: RH1028 -2 HEAD DEMMAND CALC Reoort Descriotion: Residential Pipe Type Diameter Flow Velocity Downstream Upstream Elevation Discharge K-Factor ..... Route I ...... DR 1.1010 17.00 5.73 101 42 20'-7 20101,4 17.00 4.9 FM 1.3940 34.05 7.16 42 102 20'-10Y4 10'-1Y2 BL 1.3800 34.05 7.30 102 106 101/2 101.1Y2 BL 1.6100 34.05 5.37 106 104 10-1% 0-10% BL 1.3940 34.05 7.16 104 0-10% -1,-1y2 0.00 1 34.05 Route 2 ..... DR 1.1010 17.05 5.75 103 42 20-7 20'-101h 17.05 4.9 I Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter 487 ) = Factor 150 0.050673 4714 Pf 0.741 12.114 Sprinkler, io-c Pe -0.117 12.738 E(5'-0), T(5'-O) 14'-7Y Pv IIMüh1. Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 © M.E.P.CAD, Inc. AutoSPRlNK® VR8 v8.1.11 05/13/2011 3:13:25PM Page Job Number: RH1028 -2 HEAD DEMMAND CALC Report Description: Residential Diameter Flow Velocity HWC Elevation Discharge K-Factor Pt Pn Eq. Length I Summary Total Length AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing ON Drain Discharge gpm BalV Ball Valve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 900 FR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen-Williams Constant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Ph Normal pressure at a point in a pipe DeW Deluge Valve SP Sprig Pf Pressure loss due to friction between points DPV Dry Pipe Valve ST UG Stand Pipe Underground Pe Pressure due to elevation difference between indicated points E 90° Elbow Pv Velocity pressure at a point in a pipe EE 45° Elbow Eel 11W Elbow Ee2 22W Elbow I Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PRV Pressure Reducing Valve Pry Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cai, , © M.E.P.CAD, Inc. AutoSPRlNK® VR8 v8. 1.11 05/13/2011 3:13:25PM Page 6 , © M.EPCAD, Inc. jfi AutoSPRINK® VR8 v8.1.11 05/13/2011 3:13:30PM Page 7 © M.E.P.CAD, Inc. AutoSPRINK® VR8 v8. 1.11 05/13/2011 3:13:34PM Page 8 A Residential Flat Concealed Sprinkler engineered for a minimum design density of 0.05 gpmltt2 with low GPM requirements. Features Very low water flow requirements. ½" (13mm) Total adjustment. Thread-On/Thread-Off or Push-On/Thread Off cover attachment option. Smooth aesthetic ceiling profile. Available in brass, chrome and black plated or painted finishes. Listings & Approval Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) NYC MEA 258-93-E UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC43 and RFC49 Concealed Residential Sprin- klers are fast response residential fusible solder link au- tomatic sprinklers. Residential sprinklers differ from stan- dard sprinklers primarily in their response time and water distribution patterns. Model RFC43 and RFC49 sprinklers discharge water in a hemispherical pattern below the sprinkler deflector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprinkler pat- terns. The combination of speed of operation and high dis- charge pattern required for residential sprinklers has dem- onstrated, in fire testing, an ability for controlling residen- tial fires, and thereby providing significant evacuation time for occupants. The RFC43 and RFC49 Sprinklers provide the best form of fire protection by combining an attractive appearance and W (13mm) of cover adjustment for ease of installa- tion. The srnafl diameter cover plate is easily and posi- Bulletin 006 Rev. E 00 Model RFC43 (SIN RA0612) Model RFC49 (SIN RA0616) Residential Flat Concealed Sprinklers tively attached and blends into the ceiling, concealing the most dependable fire protection available, an automatic sprinkler system. The RFC43 and RFC49 are UL Listed Residential Sprin- klers to be installed in the residential portions of any occu- pancy in accordance with NFPA 13, 13R, & 130. The RFC43 and RFC49 can reduce the need for precise cutting of drop nipples. The threaded cover plate assem- bly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Application and Installation The RFC43 and RFC49, for residential installations, use a 165°F (74°C) fusible solder link in a tuning fork style sprin- kler frame with a drop-down deflector. This assembly is re- cessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skirt, using 135°F (57°C) ordinary temperature classification solder. When the ceil- The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 exposing the sprinkler inside to ceiling temperature. The subsequent operation of the solder link opens the waterway and causes the deflector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler deflector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The residential distribution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces significantly higher wall wetting. After a 2 5/8 inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexagonal body of the sprinkler frame. The Wrench must bottom out against the cup in order to ensure proper, safe installation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL RFC43 AND RFC49 CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135°F RATED COVERS. Cover assemblies provide up to '2" (13mm) Of adjustment. Turn the cover clockwise until the flange is in contact with the ceiling. For the push-on,Thread-off option, the cover assembly is pushed onto the cup and final adjustment is made by turning the cover clockwise until the skirt flange makes full contact with the ceiling. Cover removal requires turning in the counter-clockwise direction. In ceilings that have a plenum space above the sprinkler, the plenum space may have neutral or negative pressurization but must not be positively pressurized. Inspect all sprinklers after installation to ensure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impediment. Temperature Rating Sprinkler Cover Plate Max. Ambient ( Temp. 165*17/74°C I 135'F/57°c 100°17/38C Installation Data: RFC43 (SIN RA0612) Minimum Required Thread Size K Sprinkler Maximum Minimum Sprinkler Discharge Inch (mm) Factor Spacing Distance Distance between ft. (m) to Wall ft. (m) sprinklers, ft. (m) Flow Press. gpm (Lpm) psi (bar) 'N' (15mm) 4.3 12 x 12 (3.6x3.6) 6 (1.83) 8 (2.43) 12 45) 7.8 (0.54) ½" (15mm) 4.3 14x 14(4.3x4,3) 7(2.13) 8 (2.43) 13(49) 9.1 (0.63) ½" (15mm) 4.3 16 x 16 (4.9x4.9) 8 (2.43) 8 (2.43) 13 (49) 9.1 (0.63) 1/2 (15mm) 4.3 18 x 18(5.5x5.5) 9(2.74) 8(2.43 18(68) 17.5(1.21) ½" (15mm) 4.3 20 x 20 (6.0x6.0) 10(3.05) 8 (2.43) 21(79) 23.8 (1.64) Note: 1 bar = 100 Kpa Installation Data: RFC49 (RA0616 Minimum Required Thread Size K Sprinkler Maximum Minimum Sprinkler Discharge Inch (mm) Factor Spacing ft. (m) Distance to Wall ft. (m) Distance between sprinklers, ft. (m) Flow Press. gpm (Lpm) psi (bar) ½"(lSmm) 4.9 12x 12(3.6x3.6) 6(1.83) 8(2.43) 13(49) 7.0 (0.48) ½" (15mm) 4.9 14 x 14 (4.3x4.3) 7(2.13) 8(2.43) 13(49) 7.0(0.48) ½" (15mm) 4.9 16 x 16 (4.9x4.9) 8 (2.43) 8 (2.43) 13(49) 7.0(0.48) ½" (15mm) 4.9 18 x 18 (5.5x5.5) 9(2.74) 8(2.43) 17(64.3) 12.0(0.83) 'N' (15mm) 4.9 20 x 20 (6.0x6.0) 10(3.05) 8(2.43) 20(75.7) 16.7(1.14) Note: 1 bar = 100 Kpa jFOR SLOPED CEILING APPLICATIONS SEE RASCO BULLETIN 035. 1 Maintenance Model RFC43 and RFC49 Concealed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. 135°F (570C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange allong a ½" cover plate adjusflnent. Any secure engagement between the cover plate and the cup will assure that the drop-down deflector is properly located below the ceiling.. A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the drop-down sprinkler deflector from damage, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty —specify]. Residential concealed sprinklers shall be Reliable Model RFC43, SIN RA0612 (Bulletin 006) or Model RFC49, SIN RA0616 (Bulletin 006). Model RFC43 and RFC49 Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed low flow residential concealed sprinklers with drop-down deflector and adjustable flat cover plate engineered for a minimum design density of 0.05 gpm/ft2. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon-coated Belleville spring washer and machined brass cap water seal assembly containing no plastic parts. Sprinkler K-factor shall be nominal 4.3(62.4), having a 7/16" orifice. Temperature rating shall be Ordinary 165°F (749C); cover plate temperature rating to be Ordering Information Specify: Sprinkler Model Cover Plate Finish Thread-On or Push-On Feature Cover Plate Finishes ('> Standard Finishes Chrome White Special Application Finishes Bright Brass Black Plating Black Paint Off White Satin Chrome rn Other colors and finishes available. Consult factory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. 1 x 7/2" REDUCING TEE OR ELBOW JLLJ4 D. HOLE IN CEILING " [58.7mm] DIA CUP 1 2" (50.8mm] MAX. FACE OF P117/NC TO FACE OF CEILING DIMENSION CEILING -I " [72Jmm] MAX. _ COVER ADJUSTMENT ." o ASSEMBLY -- [84. MM 864. 16 mm] COVER PLATE COVER PLATE., 1/2" r,2. 7mm] ADJUSTMENT 3. Reliable..,For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Supertrol electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Are department Connection The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable spnnkler contractors located throughout the United States, Canada and foreign countries. Manufactured by: The Reliable Automatic Sprinkler Co., Inc. Recycled R Iii bI (800) 431-1588 Sales Offices Paper (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate u dated or new data www.reliablesprinkter.com Internet Address E.G. Printed in USA. 1Z16 P/N 9999970261 Bulletin 135 v.E Model Fl Residential Sprinklers Model Fl Res Siin1ders engineered for the lowest flows to meet the minimum design density of AS gpmflt Types: F1 Res 49Pendent Fl Res 49 Recessed Pendent/F1 Fl Res 49 Recessed Pendent/FP Fl Res 58 Pendent Fl Res 58 Recessed Pendent/F1 6, Fl Res 58 Recessed Pendent/FP Fl Res 49 CCP Pendent Fl Res 58 CCP Pendent F1 Res 44HSW 10, Fl Res 44 Recessed HSW/F2 Fl Res 58 HSW Fl Res 58 HSW Recessed HSW/F2 F1 Res 44SWC Fl Res 40 HSW Fl Res 40 Recessed HSW/F2 Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) NYC MEA 258-93-E UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516893 applies to the Model Fl Res 49 & 58 Pendent Sprinklers Product Description Model Fl Res Pendent sprinklers (Figs. 1, 2,3. & 4) are fast response sprinklers combining excellent durability, high sensitivity glass-bulb and low profile decorative design. The Fl Res Horizontal Sidewall sprinklers (Figs. 5,6 & 7) are equally attractive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers, with a K-Factor of 4.9, permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard ). Upon lire conditions, rising heat causes a sprinkler's heat-sensitive glass-bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a lire. , F1 Res 49&58 F1 Res 49&58 Recessed Pendent/ Fl Recessed Pendant/F Fl Res 49&58 Fl Res 44&58 CCP Pendent Recessed HSW/F2 C, Fl Res 44 SWC Fl Res 40 Recessed HSW/F2 Technical Data: Thermal Sensor: Nominal 3mm glass-bulb Sprinkler Frame: Brass Casting Sprinklers Pressure Rating: 175 psi Factory Hydrostatically Tested to 500 psi Thread Size: 1/2"NPT0 1/2) K-Factor 4.9 (Actual) - Fl Res 49 Pendent Sprinkler 5.8 (Actual) - Fl Res 58 Pendent& HSW Sprinkler 4.4 (Actual) - Fl Res 44 HSW Sprinkler 4.0 (Actual) - Fl Res 40 HSW Sprinkler Density: Minimum 0.05 gpm/ft2 Application Model Fl Res Sprinklers are used for Residential Fire Protection according to UL 1626 Standard*. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The National Fire Protection Association or the approving authority having jurisdiction. * Effective date 7/12/02 The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Installation Models Fl Res sprinklers are to be installed as shown. Model Ft F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Model Fl Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res Pendent sprinklers use only the Model D sprinkler Wrench; for installing Models Fl Res Recessed Pendent, COP & SWC sprinklers use only the Model GFRl sprinkler wrench; for installing Model Fl Res Recessed HSW sprinklers use only the Model GFR1 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install Fl Res 44 and 40 HSW with a ceiling to deflector distance of 4" 12". Flow arrow on deflector must point away from near wall and "Top" marking must face ceiling. Model Fl Res 49 & 58 Pendent Model Fl Res 49 & 58 Recessed Pendant I Fl Fl escutcheon, " (19mm) adjustment Fig. 1 1-1g. Technical Data: Fl Res 49 Pendent and Recessed Pendent tiitj h nn*. Fl nr F:9 flt Sprinkler I Max. Thread! Temp. M Ambient Actuall Sprinkler i size 1 Rating Pressurel Temp. K 1 Length psi (bar) " Inch (mm) NPT 1 100 38 17512 Factor (R) 175 79 150 66 1 "A" FaceOffitth1gt0 Ad9NOTtOntI' Type hich (mm) Inch (mm) Inch Fl 3'(19.0) . F2 (12.7) * Note: Escutcheons Fl or F2 may be used with Model Fl Res 49 & 58 Recessed Pendent Sprinkler Deffector-to-ciling Maximum 1" (25mm) to 4" (100mm) Max. Sprinkler Spacing ft (m) _ Flow g pm (Lpm) [Pressure psi (bar) Sprinkler Identification Number (SIN) 12x 12(3.6x3.6) 13 (49) 7.0 (0.48) R3516 14 x 14 (4.3x4.3) 13(49) 7.0 (0.48) 16 x 16 (4.9x4.9) 13 (.49) 7.0(0.48) 18x 18 (5.54.5) 17(64.3) 12.0 (0.83)_ 20x20(6.1x6.1)j 20(75.7) 16.7(114) *D er..bu,g 2 PJbidmm4" (100mm) to ifi () rMax. SprinFfOw-.--1 Pressure Sprinkleil Spacing gpm (L.pm) psi (bar) entificaffon ft (m) Number (S!!) 12* 12 (3.6x3.6) 15 (57) 19.4 (0.65) R3516 14 x 14 (4.3x4.3) 160.5) 10,6(0.73) . 16 x 16(4.9x4.9) 6.T(4.3) 12.0(0.83) 18x 18(5.5x5.5) 1 19(72) 15.0(1.0) 20*20(6.1x6.1) 22(832) 202(1.4) *Note: The Fl Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: Maximum beam depth =-7" (178mm) Beam spacing ator greaterthan 7.5 ft. (2.3m) on center. Technical Data: Fl Res 58 Pendent and Recessed Pendent IThread Temp. I Sprinkler IMaL 1 I Max. Ambient I K Spunkier Size Rating Pressure Temp. I Factor Length Inch (mm) "F I I OF I 'C WNPT I_(R½)1175I_79 155 1 68 __175(12) _150 100 ! 38 _66 _5.8 2.25 (57) Max. Sprinkler ft (m) FlowSpacing gpm(Lpm) Pressure psl(b) cewng - Defkxft _Inch(mm) Spriflkier is Identification mberSN 4 12 x12(3.6x3.6) 16(61) 7.6(0.53) 1-4 (25-100) R3513 14x14(4.3x4.3) 16(61) 7.6(0.53) 16*16(4.9x4.9) 16(61) I 7.6(0.53) 18x18(5,54.5) 19(72) 10.8(0.75) 20x20(6.1x6.1)1 22(83.3) 14.4(1.0)1 3. Model Fl Res 49 & 5 • Model Fl Res 49 & 58 ccP Recessed Pendent / FP 1 FP push-on/thread-off escutcheon 5/8 [66. 1,--] OM. 2 5/76 Ow. - HOLE IN CE7L.WG [587mmJ—- C'J r/ ,tDLiCER CUP MLING VAX AACE Or Mr/M OImSvSm .4. ObfR 4€JU$ThENT HnT L I 35FGO4 04. tmmJ Fl RES 49 & 58 CCP PND. Fig.3 Fig.4 4. Technical Data: Fl Res. 49 CCP Pendent and Recessed Pendent / FP CCP CCP Ontions Data: • SPrIfld CCP Sprinkler Max Thread Temp. I T ' raaL Ambient K Sprinkler Size g P(ssUIe[ Temp. Factor Lamp -F -C -F -C NFT 155 68 1351_57 175(12)j 100! 38 4.9 2.25(57) Spacing Max. Sprinkler1 Flow Pnmsure ft(m) gpm(Lpm) psi (bar) 12 x 12 (3.64.6) 13(49) 7.0 (0.48 14x 14(4.3x4.3) 13(49) 7.0(0.48) 16 x 16 (4.9x4.9) 14(53) 8.2 (0.56) 18x18(5.5x5.5) 18(68.1) 13.5(0.93) 20x20(6.1x6.1) 20(75.7) 16.7(1.14) "A" UBfl Cover Adjustment CCP Height i In (mm) In FP Data "A": FP Position Inch (mm) L Max. Recessed (11) Mm. Recessed I Nob: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceirings which have posthve pressure in the space above. Technical Data: Fl Res 58 CCP Pendent and Recessed Pendent/FP I Thread Temp. lAssmn* Max Sprer1 .1 Max Sprinkler Ambient K i Size I Rating I i (bar) inch (mm) Temp. Pressure Temp. Factor LenIh 'F j ¶ I 'C "NPT I . I (R½) 1551 68 1135 57 175 (12) 1.10038 . 58 2.25 (57) 5. Finishes " Standard Finishes Sprinkler i Fl, F2, FP Escutcheons Bronze Brass Chrome Plated Bright Chrome Plated White Polyester Coated White Painted Special Application Finishes Sprinkler Fl, F2, Escutcheons Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome Other finishes and colors are available on special order. Consult factory for details. Ordering Information Specify' Sprinkler Model Sprinkler Type Temperature Rating Sprinkler Finish Escutcheon Finish Maintenance Model Fl Res 49, Fl Res 58, Fl Res 44 and Fl Res 40 Sprinklers should be inspected quarterly, and the sprinkler system maintained in accordance with NFPA 25, 13, 130, and 13R. Do not clean sprinkler with soap and water. Ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model Fl RES 49 Residential Sprinkler Specifications Model Fl Res 49 Pendent Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)J low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpmlft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in Conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1" to 8' maximum. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 m glass bulb containing no plastic parts, and having a temperature rating of [155°F (6a'C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 4.9 (70). Standard finish: [Bronze] [Chrome-plated][White Polyester] [Special finish- specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 49, SIN R3516 (Bulletin 135). Model Fl Res 49 Recessed Pendent/Fl, Model Fl Res 49 Recessed Pendent/F2, Model Fl Res 49 Recessed Pendent/FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ff over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1' to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a Y2' NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (791C)]. Sprinklers shall have a nominal K-factor of 4.9 (70). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Recessed escutcheon assembly shall be a steel, two-pieCe escutcheon [with W adjustment (Model F2)j [with 3/4" adjustment (Model Fl)] [of push-on and thread off design with ½" adjustment (Modal FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 49 Recessed Pendent/Fl I [Model Fl Res 49 Recessed Pendent/172] [Model Fl Res 49 Recessed PendenVFP] SIN R3516 (Bulletin 135). hi] Model Fl Res 49 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/ft over the listed coverage area. Listed flows as specified by the manufacturers technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturers installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 miii glass bulb containing no plastic parts, and having a temperature rating of 155°F (681,C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate temperature rating shall be 1350F (570C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 49 CCP, SIN R3516 (Bulletin 135). Model Fl RES 40 and Fl Res 44 Horizontal Sidewall Residential Sprinkler Specifications Model Fl Res 40 Horizontal Sidewall Sprinkler Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential horizontal sidewall sprinklers engineere to provide a minimum design density of 0.05 gpmlft over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 4.0 (57. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish.- specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 40, SIN R3538 (Bulletin 135). Model Fl Res 40 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 40 horizontal sidewall sprinkler with the following modifications: Replace horizontal sidewall sprinkler" with 'recessed horizontal sprinkler.' Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 40/F2, SIN R3538 (Bulletin 135). Model Fl Res 44 Horizontal Sidewall Sprinkler Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential horizontal sidewall sprinklers engineere,d to provide a minimum design density of 0.05 gpm/ft' over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use'. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.4 (62.8). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 44, SIN R3531 (Bulletin 135). Model Fl Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 44 horizontal sidewall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 44/172, SIN R3531 (Bulletin 135). Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. o Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Supertrol electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department cOnnection The equipment presented in this bulletin is to be nstailed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factor' Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable. Products marlufactureclarddisttibutedbRELLASLEhavebeenprotecti'rgfeandproperty for over 30 years. and are installed and sei-4ced by 9-em, ost nighly qualified and reputable sprinkler conifectors located throughout the United States. Canada and foreign counties. Manufactured by The Reliable Automatic sprinkler Co., Inc. (300) 431-1588 Sales Offices Recycled (800) 848-6051 Sales Fax Paper (914) 668-3470 Corporate Offices Revision lines indicate updated or new data. www.wiiableaprinkler.com Internet Address EG. Prrted in U.S.A. 1/05 PIN 9999970235 Horizontal Sidewall Recessed Pendent HSW 1 Deflector (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised thatthe orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13, FM Global Loss Prevention Data Sheet 2-8N or other applicable standards. Quick response sprinklers and standard response sprinklers should not be intermixed. Bulletin 136 Rev-0 Model F1 FR Model Fl FR Recessed Quick Response SDrinklers w C CD -' 0, (0 Model Fl FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW 1 Deflector Model Fl FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall - HSW 1 Deflector Listings & Approvals Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters Laboratories of Canada (ULC) Certified by FM Approvals Loss Prevention Council (LPC, UK) NYC BS&A No. 587-75-SA Meets MIL-S-901C and MIL-STD 167-1 Verband der Schadenversicherer (VdS, Germany) NYC MEA 258-93-E UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV Patents: US Patent No. 6,374,920 Applies to Model Fl FR Vertical Sidewall Sprinklers. Product Description Reliable Models F1FR and F1FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models Fl FR and Fl FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR and Fl FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex- Upright Pendent Vertical Sidewall Conventional The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523 Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench InqtiIlifinn nata. Spnnklerlype K Factor ) Sprinkler Height Approval Organization Sprinkler Identification Number (SIN) US Metric sspiii Standard-Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Pbsiton J("(15mm) Standard Orifice with /2" NPT (R/2)Thread 5.6. 80 2.2" (56mm) 1,2,3,4,5.6,7 R3625 R361 %," (20mm) Large Orifice with %" NPT (R4)Thread 8.0 115 2.3" (58mm) 1,2,3,47,8 R3622t1 _R3612 '"(17mrn) Small Orificewith/2"NPT(R/2)Thread 4.2 60 22'(56rnm) 128 R3623" R3613 %" (10mm) Small Orifice with /2" NPT (R/2) Thread 2.8 40 2.2" (56mm) 1,2,8 R3621111 R3611 10mm Orifice XLHwith R3" Thread 4.2 60 56mm 4,6,7 83624 R3614 Conventional-install in Upright or Pendent Position 10mm Orifice XLl- with R% Thread 4.2 60 56mm - 83674 15mm Standard Orifice with /2" NPT (8/2) Thread 5.6 80 56mm 4,6,7 83675 20mm Large Orifice with 3/4" NPT (R)Thread 8.0 115 58mm 4.7 83672 (1) Polyester coated upright UL and ULC listed corrosion resistant. Upright Pendent . . Conventional Model FIFR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height ApprovaI Organizations Sprinkler Identification Number (SIN) US Metric (15mm) /2"NPT (RVz) 5.6 80 2.2" (56mm) 1,2,3,4,5,7,8 R3615 %'(20mm) "NPT(R) 8.0 115 231 (58mm) 1,2,3,8 R3612 (11mm) )" NPT (R½) 1 4.2 60 2.2" (56mm) 1,2,8 R3613 /2' (10mm) /2" NPT (8½) 2.8 40 2.21' (56mm) 1,2,8 R3611 10mm 8/2 4.2 60 [ 56mm 4,7 R3614 Ui) Refer to escutcheon data table for approvals and dimensions. 2 7/4 HOLE 01.4. - (57 Z--] a' 01.4 H 511 r1 IVAN COLLAR I/NIlE. lIGHT .404/NOT SPR.WIOER NRENCH ROSS i AOJu5flENr111 I'S 1/2' REDUCER PACE OF RMNG M I CEILING I CEILING DIMENSION - 2 5/8' 0/A. (66.7m,,,] —. HOLE IN CEILING 2 5/16' DIR, [58.7m1 - CUP REDUCER LiIJ h 1_ 2 Z2/J2 01.4. (12.2,,,,] 1466001_P () REFER /0 Fl & PD ESCUTCHEON 0,404 CADET FOR APPROVALS AND OI14ENS1.ONIL 2. FACE OF FITTING Oil .40./US 1/WENT TO FACE OF CEILING OIA4 ENSION,1 (I) REfER ro F,' ESCUrCHEON CAIN TABLE FOR APPROVALS 466005_A AND DIMENSIONS. Model Fl FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Thread Orifice Size K Factor Sprinkler 1 Height Approval I Organizations Sprinkler Identification Number (SIN) us Metric W' NPT(R1/2) 5.6 80 2.2" (56mm) 1,23,6,8 15mm V2" NPT (RV) 5.6 80 2.2" (56mm) R3685 LPC Approval is for Pendent position only. Orientation Deflector to Ceiling I Dimension (Mm. - Max.) I Upright 4"- 12" (102mm - 305mm) [ Pendent I 6" - 12" (152mm - 305mm) Vertical Sidewall US Patent No. 6,374,920 Model FIFR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: Approval Organizations I K Factor I and Type of Approval Sprinkler Nominal Thread Sprinkler Identification Number (SIN) Light Ordlna Orifice Size I US Metric Length I Hazard Hazard I L " (15mm) ," NPT(R) 5.6 50 2.63" (67mm) 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL, ULC and MEA Listing permits use with Fl or F2 recessed escutcheon. fJ5F04 OF FNC TO .V4L. O'MENSiCN —2 1,14''1tLE04 4'.' i57.2r', . caL,•WG TO I' '/2CuCEF—, WRN COLL4A TIC/n .4,.,4//5T WREIVCI' BC'SS I -"H r- 4&uUsT.44EJ',T (I) REFER TO Escur-cfoN CATA !ABLE F.R APPRCI'ALS ANC DIM5VS/O,VS. , • Horizontal Sidewall 3. Installation Quick response sprinklers are intended for installation as specified in NFPA 13, FM Global Loss Prevention Data Sheet 2-8N or other applicable standards. Quick response sprin- klers and standard response sprinklers should not be inter- mixed. The Model Fl FR Recessed Quick Response Sprinklers are to be installed as shown. The Model Fl or F2 Escutcheons illus- trated are the only recessed escutcheons to be used with the Model Fl FR Sprinklers. The use of any other recessed escutch- eon will void all approvals and negate all warranties. When installing Model Fl FR Sprinklers, use the Model D Spun- kier Wrench. When installing Model Fl FIR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- moval of the protectors before this time may leave the bulb vul- nerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color c 1w Ordinary 57 1 135 100"F(38°C) Orange Ordinary I 68 I 155 100°F(38'c) Red Intermediate I79I 175 150-F (66-C) Yellow Intermediate j 93 I 200 150-F (66-C) Green High 141j 286 1 225'F(107"C) Blue Not available for recessed sprinklers. Escutcheon Data Escutcheon "A" Model Approvals Aciiustment Dimension to Coiling or Wall Dirriension Fl 1 248 Max Recess (38.1mm) -X. Min Recess Y4 ' (5nm-24rwn) (19.1mm) I F2 1.2.3,4,5,7,8 Max Recess (38,11 mm) '-" Min Recess 76 (5m- 17mm) (24mm) FP 1,2 Max Recessed ()6 1,t<"(38.lmml Thread-off 1,2 . Min Recessed (2m) No Dimensional Figure for FP Maintenance The Models F1FR and F1FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle. vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage . to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes tn (2) Standard Finishes Sprinkler I Escutcheon Bronze Brass Chrome Plated Chrome Plated White Polyester Coated (4) White Painted (3) Special Application Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome 1) Other finishes and colors are available on special order. Consult the factory for details. FM Approvals is limited to bronze and brass, chrome or black plated finishes only. FP Push-on/Thread-off escutcheon. UL and ULC listed corrosion resistance. SIN numbers: R3621, R3622, R3623, R3625. Note: For )'" orifice pendent FM approved white polyester coated and UL approved white polyester corrosion resistant sprinklers refer to Bulletin 014. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Note: When Model F1FR Recessed sprinklers are ordered, the Sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is lobe installed in accordance with the latest pertinent Standards of the National Fire Protection Association. Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting Re and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States. Canada and Foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Recycted Pape (800)431-1588 Sales Offices neflabld (800)848-6051 Sales Fax Revision lines indicate updated or new data (914)829-2042 Corporate Offices www.reliahlesprinkler.corn Internet Address EQ. Pr,,,ted a U.S.A. 3j07 P,N9999970027 Upright Conventional Recessed Pendent Small Orifice Upright Bulletin 131 Rev. I co Model GFR Model GFR Recessed Quick Response Sprinklers UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV Product Description Reliable Models GFR and GFR Recessed Sprinklers are Quick Response fusible solder type automatic sprinklers. These sprinklers have demonstrated response times in laboratory tests which are five times faster than standard response sprinklers. This quick response enables the Models GFR and GFR Recessed Sprinklers to apply water to a fire much faster than standard response sprinklers of the same temperature rating. AppliCatiOn Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, de- flector style and sprinkler spacing are in accordance with the latest published standards of the National Fire Protec- tion Association or the approving Authority Having Juris- diction. Quick response sprinklers are intended for standard area coverage and standard water densities as specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed. Model GFR Sprinkler Types Standard Upright Standard Pendent Horizontal Sidewall HSW1 Deflector Intermediate Level Upright Intermediate Level Pendent Conventional Model GFR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall HSW1 Deflector Approvals Underwriters Laboratories, Inc. (UL) Underwriters Laboratories of Canada (U LC) NYC BS&A No. 587-75-SA MIL-S-901C and MIL-STD-167-1 NYC MEA 258-93-E Horizontal Sidewall Recessed HSW 1 Deflector Horizontal Sidewall HSW 1 Deflector Pendent Intermediate Intermediate Level Pendent Level Upright The Reliable Automatic SpnnkferCo., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model GFR Quick Response Upright, Pendent & Conventional Sprinklers Upright Pendent onventional Small Orifice Up Installation Wrench: Model D Sprinkler Wrench Installation Data Sprinkler Type I Nominal K Factor Sprinkler Height Approvals Sprinkler Identification Number (SIN)_ US Metric SSU SSP Standard-Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position 5.6 4.2 2.8 4.2 8.0 mm) 80 60 40 60 115 2518* (73mm) 21/9 (73mm) 2%' (73mm) 73mm 21y1j,'(75mm) 12,3,6,7 1,2,3,7 1,2,3,7 1,2,3,7 R3125 R3115 W (15mm) Standard Orifice with 1,4' NPT (1R½) Thread (11° (11mm) Small Orifice with 1/2 NPT (R½) Thread 3/, (10mm) Small Orifice with W NIPT (FP/s) Thread (10mm) 10mm Orifice XLH with R% Thread 1%2'(20mm) Large Orifice with 34' NPT (R%) Thread R3123 R3113 R3121 R3111 R3124 R3114 R3127 R3117 Conventional-Install in Upright or Pendant Position 4.2 5.6 60 80 . 73mm 73mm ---------- R3174 R3175 10mm Orifice XLH with R3/ Thread 15mm Standard Orifice with 1,4's NPT (R½) Thread Model GFR Quick Response Upright & Pendent Intermediate Level Sprinklers 4-1/2 0/a. - [114.3mm3 I Lt To at Ieotewtieo Spring Shield (8Z3mm] .5-7/16 RA CO Saninkler i- Assemby t3llNflJ-8 Upright Installation Wrench: Model D Sprinkler Wrench Installation Data 4-1/2' Dia. [114.3mm] -1 To Be Assembled At Installation - RlflR j 03Y 2-7/8' (73.0mm] T Ring Assembl Sprinkler y ?JlW7P-8 Pendent Sprinkler Type Nominal K Factor Sprinkler Height Approvals Sprinkler identification Number (SIN) US Metric SSU SSP Standard Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position 5.6 80 217s' (73mm) 2'5Xe'(75mm) 1,2,3,7 1,2,3,7 R3195 R3115 ½' (15mm) Standard Orifice with 1/2' NPT (R½) Thread R3197 R3117 8.0 I 115 l7/ (20mm) Large Orifice with 3/4' NPT (R3/4) Thread NOTE—The protective shield must be assembled in the field per the assembly drawings. 2. Model GFR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW1 Installation Wrench: Model 0 Sprinkler Wrench Installation Data Nominal Nominal K Factor Approval Organization and Type of Approval Sprinkler Light Ordinary Sprinkler ident. Number I Orifice Thread Size US Metric Height Hazard Hazard (SIN) 1W(15rnm) ½' NPT(R½) 5.6 80 34 '(84mm) 1,2,3.7 1,2,37 P3135 '(11mm) W NPT(R½) 4.2 60 31.,'6' (1 4mm) 12,3.7 - P3133 3ç(lomm) Y NPT(R½) 2.8 41 3n(84mm) 12.37 - P3131 1 2 (20mm) 34" NPT(R½) 8.2 119 (84mm) 1,237 — P3137 Model GFR Quick Response Recessed Pendent Sprinklers Installation Wrench: Model GFR1 Sprinkler Wrench Sprinkler Type Nominal K I SnFactor rinkler Ileight Sprinkler Identification Approval&' Number (SIN) US Metric W(15rwn) Standard Orifice 5.6 80 2%" (73mm) 12,3,7 R3115 with W NFI(R½) Thread 41"(11mm) Small Orifice with 4.2 60 2%" (73mm) 1,2,3,7 R3113 WNPT(Thread %"(10) Small Orifice -with 2.8 40 2%" (73mm) 1,2,3,7 P3111 WNF/4 Thread 1Cmm Orifice with R1. 4.2 60 (73mm) - P3174 Thread '%2"(201Tr1) Large Onfice 8.0 115 213<'(75mm) 1,2,3,7 P3117 with V NPr (R%) Thread Refer to escutcheon data table for specific escutcheon approvals and dimensions. 2 '/4'(57."1 So. ..,0 ,3. o, ooh, SrnSo00\ ri .Jo3 vtl 2 27/32' Jiitc0-6 (72.2'..o) Model GFR Quick Response Recessed Horizontal Sidewall Sprinklers' Deflector: HSW1 Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data Nominal Thread Size Nominal K Factor Sprinkler Approval Organization"' TYPO Of Approval Sprinkler Identification Number Light Ordinary Orifice NPT USMetric Height Hazard Hazard (SIN) 1W(15rnm) W(R½) 5.6 81.0 33g'(84mm) 1.2,3,71 1,2,3,7 R3135 (11 mm) 1/2'(13½) 4.2 61.0 31' (84mm) 1,2,3,7 - P3133 ç(10mm) W(R½) 2.8 40.6 3'c'(84mm) 1,2,3,7 — P3131 %°(20mm) 4'(R½) 8.0 118.2 31'(84mm) 12,3,7 — R3137 Refer to escutcheon data table for specific escutcheon approvals and dimensions. 3. 0oL 440,9.001 Model GFR & GFR Recessed Quick Response Sprinklers Installation Quick response spnnklers are intended for standard area coverage and standard water densities as specified in NFPA-13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. The Model GFR Recessed Quick Response Sprinkler is to be installed as shown. The Model Fl or F2 Escutcheonsil- lustrated are the only recessed escutcheons to be used with the Model GFR Pendent or Horizontal Sidewall Sprin- klers. The use of any other recessed escutcheon will void all approvals as a quick response sprinkler and negate all warranties. When installing Model GFR Sprinklers, use the Model 0 Sprinkler Wrench and when installing Model GFR Re- cessed Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may cause sprinkler damage. Maintenance The Models GFR and GFR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean the sprinklers with soap and water, ammonia or any other cleaning fluids. Re- move any dust using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installa- tion, sprinklers should be maintained in the original cartons and packaging until used. This minimizes the potential for damage resulting in improper operation ornon-operaon. Ordering Information: Specify Sprinkler model Sprinkler type Orifice size Temperature rating Sprinkler finish Escutcheon type Escutcheon finish (where applicable) Note: When Recessed Model GFR/F1 or F2 are ordered, sprinkler and escutcheon are packaged separately. Sprinkler Types Standard Upright Standard Pendent Sidewall - Horizontal i-ISWl Deflector Conventional Recessed - Pendent - Horizontal Sidewall HSW 1 Deflector Intermediate Level - Upright - Pendent 1:1niahaC012) Standard Finishes Sprinkler Escutcheon Bronze Chrome Plated Brass Chrome Plated Special Application Finishes Sprinkler Escutcheon_ Bright Brass Black Plated Satin Chrome Bright Brass Chrome Plated San Chrome Other finishes and colors are available, consult factory for details 2f All sprinklers have black painted solder links Tømnerature Ratinas Classification Sprinkler Rating Maximum Ambient Temperature F °C ¶ Ordinary 165 74 100 38 Intermediate 212 100 150 66 Fsttitchann Data Face of Fitting Escutcheon Approvals Adjustment To Ceiling or Model Wall Dimension Fl 1,2,3 1,2,3, 3" (19mm) tç (13mm 3' mm mm) F2 I tNrnm7~~Inn) The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research corporation. or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and lareign countries. Manufactured by Rallabld The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914)668-3470 Corporate Offices www.reliablesprinkler.com Internet Address ®Recycled Paper Revision Ores indicate updated artiest data SC. Pinted In U.S.A. 7.105 P1N9999970024 SPRINKLER COMPANY The RESI-RISER tire sprinkler riser is a pre- assembled, compact, attractive unit for residen- tial sprinkler risers in NFPA 13, 130 and/or 13R systems. Brass construction makes RESI-RISER the ideal choice for use with potable water systems. The manifold portion of the RESI-RISER is manufactured from a one-piece brass casting, air tested at the factory for leaks. Raised letter- ing on both sides allows for the unit to be installed to the right or left, and also easily identi- ties the flow direction, as well as Test and Drain outlets. Two mounting legs are molded onto the manifold, allowing secure fastening to joists. The dedicated flow switch used with RESI- RISER has been tested and approved by its manufacturer, System Sensor. This quality flow switch is UL listed and FM Approved, and con- tains dual SPDT switches with an adjustable retard time of 0-70 seconds. A slim flow switch and the RESI-RISER's unique design of installing all the components to one side, while molding the mounting legs on the. opposite side, gives it the ability to be installed within 2x4 wood frame construction. An optional pressure relief valve is available for use with CPVC iystems, or in accordance with NFPA 13 Section 3-1.2, which requires a pres- sure relief valve on gndded systems. 1 1 Manifold Body, Male Thread x Male Thread 2 1 In-Line Check Valve, Spring Loaded 3 1 2" Water Gauge, 300PSI 4 1 Ball Valve 5 1 Flow Switch with Retard 6 1 9lY Street Elbow 1" For more information, call your Gem Representative today, or visit us on the Internet at: www:gemsprinkler.com Technical Data Sizes: 1", 11/4', 1h/2 and 2" Style: Thread x Thread Listings: Flow Switch and Pressure Gauge are UL Listed Finish (Riser Body): Cast Brass Water Pressure Gauge: 300 PSI Optional Accessories: 175 PSI Rated Pressure Relief Valve Flow Switch without Retard tL/cO /F/ow lGem / Control / Sprinkler DISTRIBUTED BY UNITED STATES GEM SPRINKlER COMPANY HEADQUARTERS 323 East 151st Street Maive IL 60426 Phone: (877) 4364926 Far (877)866-9250 www.gernsprinkter.com ASIA SINGAPORE (85)847-6680, Fax (65) 847-3919 MAL4YSIA P'e.taltnjJaya: (60) (3) 572-2773 Fax (60)(3) 572-2755 N(7rGING kowraOh (852) 2166-0860k Fax (852)2766-3070 TAMN mipoi:($86)(2) 377-6226, Fax (886) (2) 377-5991 kSERALiA NEW5O&THWfLES HOxtcàPax (02) 607-8133 Fax (02)608-4224 QUEENS 'AD Rockfu: (07)274-2575. Fax (07) 274-2858 501/ENAIASTIALIA AthotPeek..(08).288-4722, Fax (08)347.4892 INOURNE tundoqrff. 3) 9487 7122, Fax (03)94677526 PN4ITSTEALM WeleapooL 09)35342Z Fax (09)353-4015 JIRNLS 1perteden1 NL7547TJEnschede PO664 7500 AD 1)i53-423-3434 Fax (31)53-426-3377 *.EEU' .cJNDoM Sthdpoxt(4461-429-9730 Fax (44)61-429-9735 PRICE Pe,á-Noidll (33)148178727 Fax (33) 148178720 D-83110Rodgau (49) 610684455 Fax (49)610618177 Coo (Ma*(03)341669-3906 Fax(03)3416692018 LATIN AMERICA AAR&* USA (305)448-41059. Fax (305) 448-1632 ARGENTINA 8uOnA(res (54-11) 4246-7432, Fax (54-11)4248-4487 BusitosAkes: (54-11) 4308-8444. Fax (%%43084445 Madoza (54261) 498-0642, Fax (54261)496-1765 RIo' DáJaneko: (5521) 248-9695. Fax (5521)2404770 Somàba-São Paulo: (5515)228-3555. (5515)228-3391 CliME AttöstL (58-55)27-5548, Fax (56-55) 27-5624 sg.: 58-2-538-1800. Fax 56-2-538-0050 41ffEicQ Giiaa: 52-3-668-4000, Fax 52-16684012 52-5-207-5766, Fax 52-5-207-7566 VE1Z ELf Cáse 58-24991-7577, Fax 58-2-991-6409 Me,calbor 58-61-91-0526, Fax 584i1-93-1804 PERU Uma 511-431-1414, Fax 5$1423-8282 NEW ZEALAND AUCKLAND (09)827-2290, Fax (09) 827-2288 #127/ Printed in USA RPI / 4.00 1 1.5M I 0 2000 Fig. 22- Hanger for CPVC Plastic Pipe - Single Fastener Strap Type Size Range — 3/41 thru 2" CPVC pipe Material — Carbon Steel, Pre-Galvanized Function — Intended to perform as a hanger to support only CPVC piping used in automatic fire sprinkler systems.. The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Figure 22 can be installed on the top of a beam, but in this situation acts as a guide to the piping which is supported by the beam itself. It Is not intended to support CPVC pipe from under a flat horizontal surface, such as a ceiling. For this type of installation, use the TOLCOTI Fig. 23. Double Fastener Strap for CPVC Piping. Fig. 22, when inverted, with the hanger tab downward, can function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13,13R and 13D. Featureà --. Fig. 22 incorporates features which protect the pipe and ease Installation. The flared edge design' pro- tects CPVC pipe from any rough surface. It is easily attached to the building structure using the special UL-Listed hex head self threading screw furnished with the product, this is the minimum size fastener acceptable. It Is recommended that rechargeable electric drills fitted with a hex socket attachment to be used as Installation tools. No Impact tools (such as a hammer) or Impact fasteners (such as drive screws or nails) are allowed. Damage has been know to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish — Pre-Galvanized Note — Fastener into light gauge metal may be ordered separately. Minimum acceptable: #10 x 1' Hardened Self Threading Screw with 5/16" hex washer head. Order By — Figure number and CPVC pipe size. Patent Pending Dimensions • idelghts cPvc Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3/4 The VI,, 1'!,, 51!. 5/16 9 1 2 111. 1 1I14 11I1, 6 5/16 9 11/, 3/,, VI. 11!1. 61!, 5/16 11 il/, . 31/,, iv. 11!14 7 5/16 12 2 31/4 21!, VI.. 8 5/16 15 D on d r c'i.csfng Facility 1375 SaçiiAt Cia. CA 9Z879 • ph: T9.117.5599 . r W9.737.0330 Custorie S.r,Ic, • 000106.5266 wwwteko.cam 4- Fig. 23 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type Size Range - 3/4" thru 2° CPVC pipe Material - Carbon Steel, Pre-Galvanized Function -- Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 23 can also be installed on the side of a beam. The Fig. 23 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support tire sprinkler piping. Meets and exceeds the requirements of NFPA 13, 13R and 130. Features - Fig. 23 incorporates features which protect the pipe and ease Installation. The flared edge design protects the CPVC pipe from any rough surface. It also Incorporates snap restrainers allow- ing easier and faster installation. Easily attaches to the building structure using the two UL Listed hex head self threading screws furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installa- tion tools. No impact tools (such as a hammer) or impactjateners (such as drive screws or nails) are allowed. Damage has been known to result from Installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish - Pre-Galvanized Order By - Figure number and pipe size * Patent Pending ,** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. - Dimensions 'Weights cpvc Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt.iioo 3/4 311. VI, 1'/. 59/1 5/16 9 1 311. 11 I. 111. 6 5/16 11/4 41/, Tht 1'!. 61I1 5/16 11 Vh 47. 2732 11!' 7 5/16 12 - 2 41/. 21/,4 1'!. 8 5/16 15 oniceiMar.dact'.iringradflitr 1375SJnIpO1AYe. .CorLCA 92079 .Ph %9,7375599 . 009.731.0330 Customei Secv7cs • 000.186.5266 VWWJQ/CøCC,1, Fig. 24- Hanger for CPVC Plastic Pipe - Double Fastener Strap Type - Side Mount Size Range - 3/4° thru 2° CPVC pipe Material - Carbon Steel, Pre-Galvanized Function— Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support tire sprinkler piping. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features - Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws** furnished with the product. It Is recommended that rechargeable electric drills fitted with a hex socket attächmentbe used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole In wood is required. Finish - Pre-Galvanized Order By - Figure number and pipe size * Patent Pending ** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions Weights crvc Max. Hanger Fastener Hex Approx. Pipe Size A B Spacing (FL) Head Size wt./100 3/4 2i4 i'i, vi,,51/z 5116 9 1 2'!. 1'!, 1 /14 6 5/15 1/4 3 1'/i li/s 611, 5116 11 1/1 3'/ .1'!, 1'!,, 7 5/16 12 2 3"7,, V/u 11I.4 8 5/16 15 OtflceMrsf3cftsft'g Facility t375 Sarvpsc*, Ave. • Coiia. CA 92879 • Ph: 909 7375599 -fat: 909 737 0330 Customer Service • 600. 166.5266 wv.wtatco.casn In Fig. 27 Fig. 27A Fig. 27/Fig. 27A FIG. 27 WJFIG.27A n. Fig. 27 & 27A "Stand-Off" Hanger/Restrainer for CPVC Plastic Pipe Size Range - 3/4" and il CPVC Plastic Pip?. Material - Carbon Steel, Pre-Galvanized Function - Designed to be used as a hanger/restrainer** for CPVC piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: Flared edge design protects CPVC from any rough or abrasive surfaces. Snap-in retainers hold pipe firmly in place during installation. The "Stand-Off" design eliminates the need for wood block extension. Can be installed on horizontal or vertical piping regardless of mounting surface orientation. Attaches easily to wood structure with two hex head self-threading screws furnished with product. Installs easily using rechargeable electrical driver with 5/16' sockets, eliminating impact tool damage to pipe. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Important Note" - When installed In slot opening on Fig. 27, Fig. 27A provides additional stability and satisfies the UL vertical restraint requirement where needed. Order By - Fig. 27; By figure number and CPVC pipe size Fig. 27k By figure number and CPVC pipe size US and International Patent application in process. "For other sizes, consult factory. Fig. 27 and Fig. 27/27A have also been tested by UL mounted on 318) composite wood web material (such as TJI Series/Trus Joist Madfvlillan) without the use of back-up wood blocking. When using Fig. 27 and 27A in combination on 3/8' web to satisfy the UL requirement for vertical restraint, install two reinforcing speed nuts (Fig. 27B). Fig. 27B is UL Listed Qniy when used with TOLCOTM products. FIG. - -- cj......... __ FIG 27 - FIG 27 FIG?? WFIG 27A Typical Applications OfllceRl4anufacWring Facility. 1375 Sampan Ave. 'Corona. CA 9279 • Ph. 91.737.5599. F 91,737,0330 Customer Service • 800 736 520 www.tolco.com 4- 510 C.P.V.C. - STEEL - COPPER HANGER SIZE - 3/4" thru 3" pipe. MATERIAL - Carbon Steel. FINISH - MU. Galvanized. LISTINGS - c9us EX4231,EX 2551 FUNCTION - Hanger/restrainer on C.P.V.C., Copper or Steel pipe. INSTALLATION- PerN.F.P.A. 13,1311 and 13D on top, bottom or side of beam. Space by pipe type. On copper - insulate pipe FASTENERS - UL Listed per NFPA 13. in WOOD: 314" - 3" CPVC pipe - #905 screw - no pre-drill. 314" - 2' Copper pipe - #905 screw - no pre-drill. 3/4" -2" Steel pipe - 1/4"x1 1/2' lag screw - no pre-drill. in STEEL: 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 314" - 2" Copper pipe - 1/4" or #14 Tek Screw. 3/4" - 2' Steel pipe - 1/4' or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCO,V #905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. *CAN ALSO BE USED TO REPLACE - #500 Pipe Strap #520 Tin Strap Index 04/03 511 SIDE MOUNT C.P.V.C. - COPPER HANGER SIZE - 3/4" thru 2" pipe. MATERIAL - Carbon Steel FINISH - Mu. Galvanized. LISTINGS - c®us EX4231,EX 2551 FUNCTION- Hanger on C.P.V.0 and Copper pipe. INSTALLATION-Per N.F.P.A. 13,13R and 13D on top or bottom of beam. Space by pipe type On copper. insulate pipe. FASTENERS - UL Listed per NFPA 13. in WOOD: CPVC pipe - #905 screw - no pre-drill. Copper pipe - #905 screw - no pre-drill. in STEEL: CPVC pipe - 1/4" or #14 Tek Screw. Copper pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFC01V#905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. / Side 'view As Hanger on Metal Stud I Index I Front View - As Hanger on Metal Stud 3/03 512 C.P.V.C. - COPPER HANGER < Mo SIZE - 3/4" and I" pipe. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - -@-- EX 4231 FUNCTION - Tab up = Hanger/restrainer on C.P.V.C. or Copper pipe. Hanger! Restrainer Tab down = Hanger on C.P.V.C. Or Copper pipe. INSTALLATION - Per N.F.P.A. 13 13R and 13D on side or top of beam. Space by pipe type. On copper - insulate pipe. FASTENERS - UL Listed per NFPA 13. in WOOD: CPVC pipe - #905 screw - no pre-drill. Copper Pipe - #905 screw - no pre-drill. in STEEL: CPVC pipe - 1/4"or #14 Tek Screw. Copper pipe - I/4"or #14 Tek Screw. FEATURES * Clips on pipe = FAST INSTALLATION. Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCOiV#905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. Index Hanger Stabilize - Only 3/03 / 513 C.P.V.C. - STEEL - COPPER HANGER 1 H In SIZE - 3/4' thru 2" pipe. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. -LISTINGS - us EX 423 1, EX 2551 FUNCTION -Tab up = Hanger on C.P.V.C. ,Copper or Steel pipe. / Tab down = Restrainer on C.P.V.C. ,Copper or Steel pipe. INSTALLATION - Per N.F.P.A. 13,13R and 13D on side or top of beam. Space by pipe type. On copper - insulate pipe. FASTENERS - UL Listed per NFPA 13. in WOOD: CPVC pipe - #905 screw - no pre-drill. Copper pipe - #905 screw - no pre-drill. Steel pipe - I/4"x1 1/2" lag screw - no pre-drill. in STEEL: CPVC pipe - 1/4' or #14 Tek Screw. Copper pipe - 1/4" or #14 Tek Screw. Steel pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Required AFCON #905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. Index '4- 3/03 513-X DOUBLE OFFSET C.P.V.C. - STEEL - COPPER COMBINATION HANGER SIZE - 3/4" thru 2" pipe. MATERIAL- Carbon Steel, FINISH - Mu. Galvanized. LISTINGS - C'..$/US EX 4231 as hangerfrcstraincr combination. FUNCTION - Hanger/restrainer on C.P.V.C., Copper or Steel pipe. INSTALLATION - Per N.F.P.A. 13,13R and 130 as shown. Space by pipe type. On copper - insulate pipe. FASTENERS - UL Listed per NFPA 13;' in Wood: CPVC pipe - #905 screw - no pre-drill. Copper pipe - #905 screw - no pre-drill. Steel pipe - 1/4" x 1 1/2" lag screw - no pre-drill. in STEEL: CPVC pipe - 1/4" or #14 Tek Screw. Copper pipe - 1/4" or #14 Tek Screw. Steel pipe - 1/4" or #14 Tek Screw. FEATURES * Offset * Require~'AFCON#905 screw has a 5/16" hex head - included. ORDERING - Part # and pipe size. Index 3/03 514 OFFSET C.P.V.C. - STEEL - COPPER HANGER Hanger! Restrainer SIZE- 3/4" thru 2"pipe. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized.. LISTINGS - ,- c&us EX 4231, EX 2551 PATENT - No. 6,648,278. FUNCTION - To support horizontal piping - C.P.V.C., Copper or Steel. Hanger and restrainer in listed mounting positions - Top, Bottom or Side. Also, provides stability on vertical piping. INSTALLATION- Per N.F.P.A 13,13R and 13D on top, bottom or side of building element. Space by pipe type. On 3/8" wood web use #906 backing nuts.- see drawing. Snap over pipe then squeeze strap back allowing pipe to slide freely. On copper - insulate pipe. FASTENERS - UL Listed per NFPA 13 in WOOD: CPVC pipe - #905 screw- no pre-drill. Copper pipe - #905 screw- no pre-drill. Steel pipe - 114"xl 1/2" lag screw - no pre-drill. in STEEL: CPVC pipe - 1/4" or #14 Tek Screw. Copper pipe - 1/4" or #14 Tek Screw. Steel pipe - 1/4" or #14 Tek Screw. FEATURES * 11/2" Offset. * 3/4" and 1" pipe size have common center-line. * Leg design produces superior strength. * Offset edge eliminates abrasion. Required AFcON#905 screw has 5/16" hex head - included ORDERING -.art # and pipe size. AFCON #906 sold separately. 07/03 Stabilize . Only B X 1_• 1a;J j C. Fig. 58 -Threaded Side Beam Bracket Size Range - 3/8" rod, pipe sizes 1/2" thru 4" Material - Carbon Steel Function - Practical and economical bracket used to support piping from wood, concrete or steel beams. Features - Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept 3/8" and 1/2" fastener bolts. Per NFPA 13: 1/2' thru 2" pipe requires 3/8" fastener, 21/2' thru 4' pipe requires 1/2" fastener.* Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved thru 4" pipe. *Note - Additionally UL has listed the Fig. 58 with fasteners as shown in table below. Finish - Plain Note - Available in Electro-Galvanized finish. Order By - Figure number and finish Dimensions 'Weights Pipe Size Oty. Fastener Type Material 2 2 2'I2 4 2 1 1 #16 x 2 Drive Screws 318 Lag Bolt 1/2 Lag Bolt Wood Wood Wood 31/2 4 4 4 2 2 2 2 1/4 x 1'I2 Lag Bolt 1/4 x 2 Lag Bolts" 1/4 x 1 tek screws 1/4 x 1 tek screws Wood Wood 14 gauge 16 gauge * No pre-drilling required Dimensions • Weights Pipe Rod Size Size A Max. Rec. Approx. B C Load Lbs. Wt.I100 112 thru 4 318 2/ 1/2 1/,5 300 14 2-114 x 2 Lag Bc& INC P dr90n Up 1o4 inch Pipe Per NFP.A - Up 104 inch. Pipe \ 2 - #916 x 2 Diwe Screws 112 Thn 2 inch Pipe 2.*14v1 yak type screws - flED Mhi 160a. Steel Up To inch Pipe Up T .1 inch D OfficeiManuracluring Facility. 1375 Sampson Ave. • Comm. CA 92679 • Ph: 909.737 5599 - Fm: 909.7370330 Customer Service • 390.7863256 - www.toko.com Fig. 78-All Steel Ceiling Plate Size Range - 3/8' rod Material - Carbon Steel Features - Attachment to wood beams, ceilings, metal decks or walls. Can also be welded to steel beams. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Factory Mutual Engineering approved. Additionally, (UL) has listed the Fig. 78 with fasteners as shown in the table below. Finish - Plain and Electro-Galvanized Note - Available in Electro-Galvanized and HOG finish. Order By - Figure number, rod size and finish Patent #5, 702,077 UL Listed Fastener Table Pipe Size Qty Fastener Type Material 1/2 -2 21 /2 -4 1/2 -2 2 2 2 #14 x 17, A-point hex-washer-head sheet metal screw 1/4 x 1 '/2 wood screws 1/4 x 1 tek screws Wood Wood Metal (18 gauge) 1/2 -2 1/2 - 2 2 2 #14 x I / A-point hex-washer-head sheet metal screw #14 x 2 A-point-hex-washer-head sheet metal screw Wood Wood thru 5/8° gyp board * No pre-.drilling Dimensions ,' Weights Pipe Size A D E Max. Rec. Approx. B C Load Lbs.° wt./100 1/2 -2 5 - 6 3 21/ 11/ 5/16 3/6 Consult factory for data 150 15 * Minimum safety factor of 5 D Office!Manuracsiring Facility . 177 Sampson Ave. Carona. CA 92979. Ph: 109 737 9599 • Fan: 709./37 0J30 Customer Service • 909.796.5206 wiww.talco.cam Dimensions 'Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Size Range - Secures 3/8 thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 98 - Rod Stiffener Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing Finish - Electro Galvanized Note - Available in HOG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8° thru 7/8' rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750'F Finish - Plain Note - Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions 'Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F WtJ100 1/4 240 215 12 - 3/8 610 540 29 112 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 - 7/8 3770 3360 169 1 4960 4420 222 1 /4 8000 7140 360 1/: 11630 10370 510 - OfficelManufactunng Facility 75 Saunioil Ave. • Cuioii. 3A 92379 . Ph' 0 7373599.109.737.330 Customer Service 3997965256 www.tolco.com Fig. 200 - "Trimline" Adjustable Band Hanger Size Range - 1/2" thru 8° pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping go purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2 thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keéps adjusting nut from separating with hanger. Hanger is easily A : installed around pipe. (21121 thru 8° Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters Laboratories listed (1/2° thru 8") in the USA (UL) and Canada (cUL) for steel . TRU 2 NCH PIPE and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8°). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F .•.-- Finish - Mu. Galvanized. For Stainless Steel materi- als, order TOLCO Tm Fig. 200WON. Ed Order By - Figure number and pipe size B 2 1,2 TRU 3CH PIPE Dimensions Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 3/9 2-1/3 400 11 3/4 3/8 8mm or 10mm 311 2/2 400 11 1 3/8 8mm or 10mm 379 2/9 400 12 1/4 3/8 8mm or 10mm 3I4 21I8 400 13 111 3/8 8mm or 10mm 31/, 2'/l 400 14 2 3/8 8mm or 10mm 41/3 3 400 15 211 3/8 10mm 53/, 41/ 600 27 3 3/8 10mm 5'11 4 600 29 311 3/8 10mm 71/9 5/ 600 34 4 3/8 10mm 73/ 5 1000 35 5 1/2 12mm 91/1 6/4 1250 66 6 1/2 12mm 10'/, 6/ 1250 73 8 - 1/2 12mm 13/9 8/4 1250 136 D OfficelManulacuirinq Facility 375 Sainimn Ave. . Ciia. CA 9ZSY9 . P11: 90 737.59 Fix: 99. 137.0330 Custom Service .P13Oi8652 www.talco.com tLICO Flo / Tyco FirelControl I Products AglazeMaster FiRE SPRINKLER PIPE & FITTINGS SUBMITTAL SHEET TYCO FIRE PRODUCTS 451 North Cannon Avenue Lansdale, Pen0insylvania 19446 www.tyco-fire.com TECHNICAL SERVICES TEL: (800) 381-9312 FAx: (800) 791-5500 E-MAI1.. techservtycofp.com TD915 4-1.1.20 9/2001 Reducing 900 Elbow Tee 'Part INo.l I Size I iSch. ljw-i:1 Lb . I J 80015 Ii' x 'I.J 40 'I? "1.']10.281 Cross Part No. I Size Sch. T/O WI. 80009 314' 40 'I." 0.131b. 80010 1" 40 "1,." 0.23 lb. 80011 1'!? 40 t$/,' 0.34 lb. 80012 1W' 80 1 1',." 0.67 lb. 80013 24 80 1W 1.00 lb. 80014 2'/2* 1 80 1'!.' 1.91 lb. 80008 1 3" 80 1111/." 2.89 lb. Reducing Cross. Introduction Tyco Fire Products (TFP) BlazeMaster' CPVC pipe and . . the same time, they provide superior heat resistance and fittings are designed exclusively for use In wet pipe strength as compared to traditional CPVC and PVC piping automatic fire sprinkler systems. They are made from a materials used in the plumbing trade. Various adapters are specially developed thermoplastic compound composed of .available to connect CPVC pipe to metallic piping. All female post chlorinated polyvinyl chloride (CPVC) resin and state of pipe thread adapters have brass inserts for durability. the art additives. TFP BlazeMaster' CPVC products are• Grooved adapters connect directly to grooved end valves : easier to Install than traditional steel pipe systems, and at and metallic pipe, with flexible grooved end couplings. Technical Data Sizes.; .3/41- 3 Manufacture Source: U.S.A. Maximum Working Pressure; 175 psi Material: Approvals: Li, FM, CUL, NSF, Dade County, LPCB, Pipe: ASTM F442, SDR 13.5 MEA, and the City of Los Angeles Fittings: ASTM F438 (Sch. 40) and Note: See current TFP BlazeMaster installation Instructions and .ASTM F439 (Sch. 80) Technical Manual, for exad listbVepproval information Color. Orange Pine Nom.Plpe Size Avg. Oil. Inches Avg. I.D. Inches Wt. Lbs IFt. Wt. ILO filled Pipe LbS.IFL. Ft. of Pipe per Lift WI. per Lift Lbs. _____ 1.050 0.874 0.17 0.43 7875 1413 1.315 1.101 0.26 0.67 5040 1320 ___ 1.660 1.394 0.42 1.07 2835 1191 VI? 1.900 1.598 0.55 1.40 2205 1136 2 2.375 1 2.003 0.86 2.20 1260 1 1063 1'2 'I? 2.875 1 2.423 1 1.26 1 3.22 1215 1531 3" 3.500 2.952 1 1.87 1 4.79 720 1344 - Fittings Tio Wo 45* Elbow Part No. Size Sch. TIO Wt. 80050 W 40 W 0.08 lb. 80051 r 40 ' /? 0.11 lb. 80052 1'I4' 40 W 0.20 lb. 80053 1/? 80 II,? 0.31 lb. 80054 2 80 W 0.56 lb. 80055 21!? 80 'I 0.89 lb. 80056 34 80 r 1 1.19.1b. 900 Elbow Part No. Size Sch. 110 1 Wt. 80025 314' 40 '1? 0.09 lb. 80026 V 40 W 0.141b. 80027 1'/' 40 W 0.21 lb. 80028 1'/,-, 80 1'/,? 0.40 lb. 80029 2 80 lb. 80030 2/? 80 #1 '. "144'.79 .14 lb. 80031 3" 80 .82 lb.1 Tb Grooved _____ Coupling - Jo.0. Adapter I Part No. Size Sch. I/O Wt. Pipe OD 80160 1'!? x 1/4, Grooved 40 2/.' 0.78 lb. 1'/4* (1.660") 80161 11? x VI? Grooved 80 2'/.' 0.95 lb. i'l:' (1.900") 80162 2' x 2" Grooved 80 2'/? 1.42 lb. 2-(2.375') 80163 2W x2'h" Grooved 80 2'/? 2.28 lb. 2W (2.875") 80164 3" x 3" Grooved 80 21!? 3.00 lb. . .3' (3.500 80168 3 x 76.1 mm Grooved 1 80 27.' 2.72 lb. 76.1mm (3.000") iTI0 Coupling -RE . Cap 1/0 Reducer - -- Bushing Part No Size Sch. I/O Wt. 80075 %# 40 11.' 0.07 lb. 80076 1 • 40 '/. 0.11 lb. 80077 - .1/4" 40 3/ 0.12 lb. 80078 l'h" 80 '1." 0.25 lb. 80079 80 3/• 0.38 lb. 80080 21h* 80 3/' 0.67 lb. 80081 80 31' 0.91 lb. Part No Size Sch. I/O WI 80100 31.'. 40 .'/?. A.04 lb. 80101 •1'- 40 3/U 0.06 lb. 80102 VI." 40 '/z"- 0.101b. 80103 1W 80 W. 0.20 lb. 80104 2" 80 .3/S 0.31 lb. 80105 2'I2' 80 80106 3 80 1" 0.88 lb. Part No. Size Sch. T/0 I Wt. 80200 1 • x 3/ 40 'As'0.04 lb. 80201 11/" x 'I.." 40 P/i,': 0.11 lb. .80202 1114'x V 40 '.I,', 0.12 lb. 80203 1/? x W 80 8/," 0.16 lb. 80204 1W x 1 • 80 Ih' A 0.14 lb. 80205 VI? x 1/? 80 31.' 017 lb. 80206 2 x 8/" 80 W 0.27 lb. 80207 2" x V 80 "1,. 0.26 lb. 80208 2" x1'/i 80 '1? 0.24 lb. 80209 2" x VI? 80 'I? 0.19 lb. 80215 21/2'X 1. 80 11$/I,. 0.42 lb. 80214 21? x 1,/.*.80 1/.' 0.45 lb. 80213 2'I?x1'Ii 80 VI? 0.461b. 80211 2'I? x 2" 80 1'I." 0.29 lb. 80210 3' x 2 80 28/? 0.72 lb. 80212 3 x2'l? 80 1'/? 0.47 lb. Reducing Part No. Size Sch. T/O I WI. 80142 8/? x 3/ NPT 40 8/? 0.41 lb. 80145 1" x V NPT 40 3/.5 0.63 lb. 80146 1/? x VI." NPT 40 '/.' 1.03 lb. 80147 1'/?x 1'/" NPT 80 1" 1.42 lb. 80148 2' x 2" NPT 80 1/.' 2.66 TIO Male - -- Adapter (Part No. Size Sch. I/O Wt._J 80157 '1: x '1." NPT 40 I'/ .".33 lb. 1'6"10.561b. L8 0158 Vx VNPT 40 10 Reducing db Coupling Part No. I Size I Sch. I/O 80220 11 -x'I" 1 40 'I? J _L_ Part No. Size Sch. TIO WI lb. r -i-- 3 80132 3/."x3/."xl 40 /? /? s/, 0.14 80133 10 x 3/45 x I? 40 'IS' "/u' I? 0.14 80134 1 • x II." x V 40 1'/.' s/a" 31? 0.17 80260 1' x 1 • X 3/4" 40 /? 3/,' "1.' 0.16 80135 1'!? x 1" x 8/." 40 'I." /? 55/5 0.21 80IB6 / 1 'I? X 1" x V 40 "/? 'I? "1? 0.22 80137 11I.' x 1' x 1 'I." 40 '/? "li? '8/i.' 0.26 80261 1/." x 1'/? x I? 40 1/5 8/." Ti" 1 0.23 80262 1W x 1 'I." x V 40 31? '1? '!? 0.26 80138 11/4*X 1'/.'x 111? 80 V 1" 1" 0.43 80140 1'Ia"x11/4'x 3/." 80 W 8/." 1' 0.36 80141 11/2"x 1'/?x V 80 '1,' 8/? 1/." 0.38 80263 1'/z'x1'I"x 3/.' 80 'I? 'I.• 1' 0.36 80264 1'!? x 1'h' x 1" 80 'I? 'I? 1 • 0.38 80275 1 Ia' X i/a" X 1 'I.'- 80 'I. '1." 1' 0.45 80265 2" x 2' x '/? 80 I., 8/.• 1'I , 0.61 80266 2" x2" x 1 80 'I? '1? 1/.' 0.66 80274 2 x 2' x l'/.' 80 V V 1'!." 0.74 80267 2" x T x 11/2" 80 1 1? 1/? IT.' 0.78 80271 2/? x 21/,'x 1" 80 1 "1? 1',..-1 It/ig' 1.43 80272 2/i' x 2'!? x 1'f? 80 111/." 1 "li.' 18/'0 1.46 80273 25" x 21/" x 1/? 80 1",." 1 55/,,' 1'/.' 1.48 80276 2/2' x 21li' x 2' 80 1"/? 1"!." 1'/." 1.50 80270 30 x 3' x 1W 80 1/." 1/." 1 91.' 2.28 80268 3 x 3' x 2 1 80 1'/. 1'/." iT? 2.25 80269 3'x3'x21/? 60 l'/.' 1W 1"/.' 2.44 Female Adapter WhereL 1) =l2eLCL e 3.4 xlo1lnilnrF(Coefficient of Linear Expansion) L = Length of Run in Feet Temperature Change in 'F An example of Thermal Expansion is shown below: A 257 chpnge in temperature will cause on expansion of Alnch for a50 foot straight length. For most operating a n d I n s t a l l a t i o n c o n d i t i o n s , expansion and contraction can be accommodat- ed at changes in direction of the pipe run. For additional information on Thermal Expansion please see Table C. Tamp Length at flea (It.) Table C' Thermal Expansion 103 .20 .41 .61 12 1.02 122 1.43 1.83 1.34 2.04 2.86 3.67 4.50 6.53 Example-.How much will a 40 foot run of Wo( fltazeMoster'CPVC pipe ___________________________________ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Increase in length (or expand) if - 1 the expected ambient temperature ranges from 351 to 85'F? Changes In Ingth due to fittings are insignificant relative to the pipe. Change s iø is so 25 30 35 40 45 50 10 08 120 160 arF Thermal Expansiea. sL (In.) 20 .04 .08 .12 .16 .20 24 .29 .33 .37 .41 .57 .73 .98 1.31 .06 .12 .13 .24 .34 .37 .43 .49 .55 .61 26 1.10 1.47 1.96 40 .08 .16 .24 .33 .41 .49 .57 .65 .73 .82 1.14 1.47 1.96 2,61 50 ,10 .20 ii .41 .51 .61 .71 .82 .92 1.02 1.43 184 2.45 3.26 60 .12 .24 .37 .49 .61 .73 .86 .98 1.10 122 131 2.20 2.94 3.92 jr .14 29 .43 .57 .71 .86 1.03 1.14 129 1.43 2.00 2.57 3.43 4.57 80 .16 .33 .49 .65 .82 .96 1.14 1.31 1.47 t.&3 2.29 2.94 3.92 $.22 .13 37 .55 .73 .92 1.10 1.29 1.47 1.65 134 237 330 4.41 5.08 Table D • Loop Length (307 to 1007) rT: 707 Nam. Pipe $ian 10 20 30 40 Length ilflutit(L) 50 69 79 80 90 100 120 140 160 Length nt Loop (fn.) W 1.050 II 15 18 21 24 25 28 30 32 33 3? 39 45 i' i3'ii 12 17 20 24 26 29 31 33 35 37 II 41 47 1.660 13 19 23 26 30 32 35 37 40 42 46 50 53 1.900 14 20 25 28 32 35 38 40 43 45 49 53 57 2.375 10 22 21 32 35 39 42 45 43 50 95 59 63 Rr IT 2.675 13 25 30 35 39 43 46 49 52 55 60 65 70 3.500 19 27 33 38 43 47 SI 54 53 61 67 72 77 PA. August 2001 UI. & C-UL File CExS988 Product Ratings and Capabilities Pressure Rating & Pressure Listing TFPBIazeMasterpipe and fittings are (ii. and C-UI. Listed and Factory Mutual Research and LPCB App r o v e d f o r a r a t e d p r e s s u r e o f 175 psi (1210 kPa) for sprinkler service up to 150'F (655C). Friction Loss TFP filazeMaster'CPVC pipe has a Hazen-Wihiarns C-Value of 150. Pipe friction loss calculations sha l l b e m a d e a c c o r d i n g t o N F P A Standards. The following table shows the allowance of friction toss for fittings, expressed in equivalent feet of p i p e . Allowance for Friction Loss is Fittings (Eguiva lent Feel at Pipe) Fitting Size (tn.) Jr f _1W _1W 1 2' I 23r Branch 3 5 8 8J10 12 Elbaw9O' 4 5 6 d3rTee 7J9 45' 1 12Elbow 1 2 J 2 3 CoupOng 1 1 1 [2 TeeRun _11 - 1 - - I - - 2 _ 'The above stated friction loss values are for TFPBIaz.Mast er® ftrrü,s only. When using other ListedB1Mer®CPVCSO elbows with UP BlazeMaster® products, please consult the fitting manufacturers installation and design manuals. Thermal Expansion fllzeMsterplasttcs, like all piping materials, expand and contract with changes in temperature. The co e f f i c i e n t o f l i n e a r e x p a n s i o n s is: 0.0000340 lncMnchtF. 8L l2eL(fl LiL= 12(.000034)x40x50 .82 in. or %' iF? BlazeMaster'CpV exhibits a relctiely high coefficient of thermal expansion (see Table C). When des l g r t i n g l T P f l l a r e M a s t e r ' s p r i n k l e r s y s - teals, expansion of tong runs must be considered if temperature ymiations will be encountered 0e summer to winter extremes). Methods o(compensating for thermal expansion me; expansion loops, offsets and change of direction of the pipe run. (See Figure G for examples of conbal methods.) The expansion loops and offset tables are shown below. if the change in temperature and the maximumwor)ilng temperature are lower than those used to derive the tables, the numbers will be conservative In nature. For example. for a t e m p e r a t u r e c h a n g e f r o m 6 0 1 t o 1 2 5 1 u s e Table F because the maximum temperature is greater than those shown In Tables Dand E For conditions which are not covered in the Loop Length Tables, use the formulas and examples found in Table H. Note: Table based on Stress and Modulus of Elasticity at lOOT. Refer to Table H on page S. Ts 701 Ss 1560 psi 3.85 x lOt psi Part No. Size Sch. I/O WI. 80175E 3/4 x '/' NPT 80 '/.' 0.20 lb. 80176E 1' x '/z' NPT 80 'I.' 0.22 lb. 80177W1 /' x 'Ia' NPT 40 0.16 lb. 80179 1 x 'I. NPT. 40 3/, 0.43 lb. Sprinkler Head Adapter (Spigot) with Brass Threaded Insert Part No: Size Sch. I/O Wt. 80175W /.x '/a* NPT 40 '1.' 0.19i 80176W 1 • x 'I? NPT 40 '1,.' 0.18 1b1 Back-to-Back Cross with Brass Threaded Insert Back-to-Back Tee with Brass Threaded Insert Sprinkler Head Adapter 900 Elbow with Brass Threaded Insert .r . Tb' I -I -1 r/o' Sprinkler Head 'Adapter with Brass Brass Threaded Insert Sprinkler Head Adapter with Brass Threaded Insert 4- [Part No. Size Sch. I/O WI. L80177l /' x 'Is' NPT 1 40 'Ia' 0.16 lb. L80178 1' x '/' NPT 40 ¼' 0.20 lb. Part 1/0 IW[1 No. Size Sc.h 1 1 21 lb. 80462 1 • x 1 x t/ NPT x 'I? NPT 40 W 1'/. 0.41 80463 1 • x 1 • X 'I? NPT X V' NPT 40 5/.' 1 1 3/, 0.471 [ Part No. Size Sch. 1/0 Wt. lb. 1 2 [ppieg 3/.'x '/' NPT 40 '/.' "/ 0.20 [80189 1'x'/aNPT 40 13/'.' 1/i.' 0.26 Part Size Sch. I/O I Wt. No.1 1 1 2 lb. 80459 V x '/z' NPT X Va' NPT 40 "I,.' 1 1%., 0.48 80460 1' x 'I.' NPTx h' NPT J 40 "I.' 1/.' 0.48 Part No. - ze Si 1/0 Wt. Sch. - -• -r lb. 80250 %' 1h' NPT 40 'I." W1 1 • 0.22 80251 1_x1 • x'I?NPT 40 "/.' "/." 'i' 0.29 1 80249 1 • X1_X 14 NPT 40 '/'.' 'ale 17t.* 0.73 80256 1'/.* x V x'I,._NPT 40 'I." I 'I.' 1/.' 0.30 80252 1/.'x1'I._x'I?NPT 40 'I.' 'I." 1'/. 0.31 53' i'iX1'I4'x_'I._NPT 80 'I.' /. 1'/.' 0.43 80254 1k' x1/? xW NPT 80 'I. ' 'I ,.' I 'I.' 0.46 80258 k' 2'x 1 x'I?NPT 80 1.80253 2x2' x'/ _NPT 80 'I." '/a' 1'/._I_0.62 Sprinkler Head Adapter Tee with Brass Threaded Insert Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for tea (10) years against defects In material and workmanship when paid for and properly Installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty Is given for products or components manufactured by cornpaiales not affiliated by ownership with Tyco Fire Products or for products and Components which have been subject to misuse. Improper InstallatIon, corrosion, or which have not been Installed, maintained. modified or repaired In accordance with applicable Standards of the National Fire Protection Association (NFP& and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced. at Tyco Fire Products sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation 'in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or Inaccurate or Incomplete Information supplied by Buyer or Buyers representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE. IN CONTRACT. TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES. INCLUDING BUT NOT LIMITED TO LABOR CHARGES. REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES. AND IN NO EMIT 5ijj,L TYCO FIRE PRODUCT'S LIABILITY EXCEED AN AMOUNT E.QUAL TO THE SALES PRICE. tqcofriowconrail Tj'co Fire I Products S (b\ )(ThTTID I • BELLS 'OTTER I 1.1 % .... Ps. A* &PBD.DC Potter Electric Signal Company Potter Electric Signal & Mfg LTD 2081 Craig Rd./PO. Box 28480 - 1967 Leslie Street St. Louis, MO 63146 Don Mills, Ontario, Canada M382&13 (314)878-43211(800) 325-3936 (416)441-1833 UL LISTED, FM APPROVED Sizes Available: 64,8', and 10' Voltages Available: 24VAC 120 VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling BurglarAlarm Environment: Indoor or Outdoor Use (See Note 1) -400 to 150°F (outdoor use require weatherproof backbox) Termination: 4 No. 18 AWG stranded wires Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar, or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4° square electrical box for indoor use, oron a model BBK-1 weatherproof backbox for outdoor applications. / ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: SIZE VOLTAGE MODEL NO. STOCK NO. CURRENT (MAX) TYPICAL d5 MINIMUM d9 I 6 12VD( P80126 1706012 I / 85 75 8 12VDC P80128 1708012 .12A 90 75 10 12VDC P801210 1710012 .12A 92 75 6 24V0C P00246 1706024 .06A - 87 75 8 24VDC P80248 1708024 .06A - 91 79 10 24V0C P802410 1710024 .06A 94 79 8 24VAC P0A246 1806024 .17A 91. 75 8 24VAC P8A248 1808024 .17A 94 75 10 24VAC P8A2410 1310024 .17A 94 75 6 120VAC P8*1206 1806120 .A 92 82 8 120VAC P8*1208 1800120 .05A 99 82 10 I I20VAC I PBAI20I0 1810120 .OSA . 99 as - Weatherproof backbox model 88K-I Stk. No. 1500001. Notes: Minimum dB ratings are calculated from Integrated sound pressure measurements made at Underwriters Laboratories as specified InUL Standard 464. UL, temperature range is .30° to 150°F. lypicaida ratings are calculated from measurements made with a conventional sound ievQ.l meter and are indicative of output levels in an actual installation. PRINTED IN USA MKT. 18850001- REV J PAGE 1 OF 2 MEG. 15400776 ("1 )(ThT T? BELLS PBA-AC & PRDDC DIMENSIONS FIG. 1 BELLS FIG, 2 WEATHERPROOF BACKBOX - S BOX HAS ONE THREADED 1,42' CONDUIT ENTRANCE • - 5 311 H 2 tI/Is H • OG. 1775-2 oWc.Ø776-1 FIG.3 • WIRING (REAR VIEW) OBSERVE POLARITY ON D.C. BELLS RED(IN) RED T) FROM CONTROL PANEL OR PRECEDING BELL BLACK _(IN))i(" O BLACK(OUT) II TO NEXT BELL OR END-OF--LINE RESISTOR 11 CAtfflON V414EN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND or LEADS AS SHOWN. DWG. #776-3 TES: OBSERt POLARITY TO RING P.C. BELLS. RED WIRES POSITIVE (4.). BLACK WIRES NEGATIVE (-). WHEN USING A.C. BELLS. TRMIMTt EACH EXTRA WIRE SEPARATELY AFTER LAST BELL ENO-OFUNE RESI S T O R I S NOT REQUIRED ON AC. BELLS. ISTALLATION . The bell should be mounted a minimum of 8 ft. from the floor or as close to thee1Ilng as possible. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanlsntmust be mounted with the striker polnng down). Reinstall the gong (be sure that the gong positioning pin, In the mechanism h u s l n g , i s i n t h e h o l e i n t h e g o n g ) . Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having Jurisdiction.' (rEDP4USA UKTM85OOO1-REVJ . PAOE20F2 UFO. 65400776