Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6485 SURFSIDE LN; ; AS120036
7/15/24, 2:02 PM AS120036 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS120036 Job Address: 6485 SURFSIDE LN Status: APPROVED Permit Type: SPRINK Applied 3/15/2012 Parcel No: 2140211200 Approved: 3/26/2012 Lot #: 0 Reference No.: Issued: 3/26/2012 PC #: Inspector: Project Title: MOORE BEACH HOUSE NEW CONSTRUCTION Applicant: SYMONS FIRE PROTECTION SUITE R 1050 PIONEER WAY EL CAJON, CA 619-588-6364 Owner: MOORE RANDAL J&CYNTHIA L 1262 KETTNER BLVD #1703 SAN DIEGO CA Fees ($) Add'I Fees ($) IL Total ($) Balance($) 393 0 393 0 about:blank 1/1 Check a License - License Detail - Contractors State License Board Page 1 of Department of Consumer Affatrq ZAZ Contractor's License Detail - License # 682025 DISCLAIMER: A license status check provides information taken from the CSLB license database. Before relying on this information, you should be aware of the following limitations. CSLB complaint disclosure is restricted by law (8&P 71246) If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below Click on the link or button to obtain complaint and/or legal action information. Per, B&P 7071.17, only construction related civil judgments reported to the CSLB are disclosed. Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. Due to workload, there may be relevant information that has not yet been entered onto the Board's license database. License Number 682025 Extract Date 3/15/2012 SYMONS FIRE PROTECTION INC 1050 PIONEER WAY SUITE R Business Information EL CAJON, CA 92020 Business Phone Number: 619) 588-6364 Entit ..,,.Corporation issue Date 12/14/1993 Reissue Date 12/17/2002 CONTRACTOR'S BOND This license filed Contractor's Bond number 167153 in the amount of $12,500 with the bonding company AMERICANCONTRACTORSINDEMNITYCOMPANY. Effective Date: 01/01/2007 Contractor'sBondingHistory Bonding BOND OF QUALIFYING INDIVIDUAL The Responsible Managing Officer (RMO) EMERY TOD EUGENE certified that he/she owns 10 percent or more of the voting stock/equity of the corporation. A bond of qualifying individual is not required. Effective Date: 08/25/2008 BQI's Bonding History Workers' Compensation This license has workers compensation insurance with the COMPANIONPROPERTY ANDCASUALTYINSURANCECOMPANY https://www2 .cslb.ca.gov/OnlineServices/CheckLicensell/LicenseDetail .aspx?LicNum6... 03/15/2012 Expire Date License Status Classifications Check a License - License Detail - Contractors State License Board Page 2 of 2 Policy Number: NWC000691 100 Effective Date: 10/01/2011 Expire Date: 10/01/2012 Workers Compensation History DATE DESCRIPTION Miscellaneous Information 12/17/2002 LICENSE REISSUED TO ANOTHER ENTITY Personnel listed on this license (current or disassociated) are listed on other licenses. Personnel List I I Other Licenses Conditions of Use I Privacy Policy Copyright © 2010 State of California https://www2.cslb.ca.gov/OnlineServices/CheckLicensell/LicenseDetail.aspx?LicNum6... 03/15/2012 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. ENGINEERS : SYNONS FIRE PROTECTION. (619) 588-6364. FILE COPY LICENSE : 682025 DESIGNER : CANDI CAUDILLO DATE : 02-28-2012 FILE : 12-038 JOB NAME : MOORE GUEST HOUSE 16FT FLAT LOCATION : 6485 SURFSIDE LANE, CARLSBAD, CA DESIGN DATA. DESIGN CRITERION: MIN SPR FLOW AREA PER SPRINKLER TOTAL CALCULATED AREA TOTAL SPRINKLERS CALCULATED FLOW DATA. plans base !leefl reviewed It aplarcill etitisplianee N FPA 13-D It' current ap1)!icable cotes and iandarls iii 0 jir Scull The ss ni or contriell ray till/C F", ries' in 11 I pp!ictlioil or a building 13 Gpm l iii he esprss Lill (It that his res Cit on tier 01 coitiractiti or then in i ssiv'CliCS the vital rilgileer it architect icr stile responsihiliI privies 256 Sq Ft [ii tutl crtilsllance wiih said codes and staiidat us. Ioi iiiclnhiig IC building code or for alil responsibilty deticicticies. errors. omissions 01 ilegtl.ItcC in these 512 Sq Ft lulls slietlier or tot noted in this res ew. mill 5N"I- 2 Heads RhC()M MEN!) APPROVAL 0 REC( )MMENI) AIPH()VAL. AS Nt TOTAL SPRINKLER FLOW 27.8 Gpm DOMESTIC DEMAND 5.0 Gpm TOTAL WATER REQUIRED 32.8 Gpm BASE OF RISER NODE: 8 FLOW: 32.8 Gpm PRESSURE: 32.9 Psi AUTHORITY HAVING JURISDICTION : CARLSBAD FIRE DEPT. PHONE : 760-602-4666 FILE COPY HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 1 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 02-28-2012 File: C:\RESDEN43\12-038.RES JOB : MOORE GUEST HOUSE 161 FT FLAT SOURCE STATIC : 75.0 Psi RESIDUAL : 74.0 Psi FLOW : 31 Gpm DESIGN I SPRINKLER MANUF : TYCO MODEL : LF II I SPRINKLER Q : .0 Gpm VALVE : .0 Psi I SPRINKLER P : .0 Psi METER : 13.0 Psi NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet ----------------------------------------------------------- FACTOR Psi Gpm 1 25.0 4.9 9.1 14.8 2 25.0 4.9 7.0 13.0 3 25.0 9.2 4 25.0 18.9 5 15.0 17.7 6 15.0 22.8 7 15.0 26.9 8 9.0 32.9 5.0 DOME 9 5.0 38.2 10 3.0 44.6 11 .0 SOURCE 65.6 32.8 SPRINKLERS FLOWING : 2 AREA PER SPRINKLER : 256 Sq Ft TOTAL DESIGN AREA : 512 Sq Ft REQUIRED DENSITY : Gpm/Sq Ft COMPUTED DENSITY : .051 Gpm/Sq Ft TOTAL SPRINKLER FLOW : 27.8 Gpm TOTAL DOMESTIC FLOW : 5 Gpm TOTAL WATER REQUIRED : 32.8 Gpm TOTAL SPRINKLER PRESS : 52.6 Psi WATER METER LOSS : 13.0 Psi VALVE FIXED LOSS : .0 Psi Copyright (2002) SUPPLY PRESS AVAILABLE : 73.9 Psi by DEMAND PRESS REQUIRED : 65.6 Psi Hydronics Engineering PRESSURE CUSHION : 8.3 Psi 34119 Fremont Bi, Suite 609 Fremont, Ca., 94555 MAXIMUM VELOCITY : 13.5 F/S (510) 487-9160 HDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 2 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 02-28-2012 File: C:\RESDEN43\12-038.RES JOB : MOORE GUEST HOUSE 16'FT FLAT PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 1 q= 14.8 K= 4.9 ----------------------------------------------------------------------- - - - - - - - - L= 7.0 Pt 9.1 Pt 9.1 1 Q= 3.6 F= 2B F= 6.0 C= 150 Pe .0 Pv .0 Vel= 1.9 D= .874 TL= 13.0 .0089 Pf .1 Pn 9.1 3 Pt 9.2 2 q= 13.0 K= 4.9 ----------------------------------------------------------------------- - - - L= 13.0 Pt 7.0 Pt 7.0 2 Q= 13.0 F= 1B1L F= 10.0 C= 150 Pe .0 Pv -.3 Vel= 7.0 D= .874 TL= 23.0 .0944 Pf 2.2 Pn 6.7 3 Pt 9.2 3 q= .0 K= .0 ------------------------------------------------------------------------- - L= 42.0 Pt 9.2 Pt 9.2 3 Q= 16.6 F= 3R2B2L F= 23.0 C= 150 Pe .0 Pv -.5 Vel= 8.9 D= .874 TL= 65.0 .1488 Pf 9.7 Pn 8.7 4 Pt 18.9 1 q= 14.8 K= 4.9 ------------------------------------------------------------------------ - - L= 26.0 Pt 9.1 Pt 9.1 4 Q= 11.2 F= 2B4L F= 34.0 C= 150 Pe 4.3 Pv -.2 Vel= 6.0 D= .874 TL= 60.0 .0711 Pf 4.3 Pn 8.9 5 Pt 17.7 4 q= .0 K= .0 ------------------------------------------------------------------------ - - L= 10.0 Pt 18.9 Pt 18.9 5 Q= 16.6 F= 2L F= 14.0 C= 150 Pe 4.3 Pv -.5 Vel= 8.9 D= .874 TL= 24.0 .1488 Pf 3.6 Pn 18.4 7 Pt 26.9 5 q= .0 K= .0 -------------------------------------------------------------------------- Lr= 39.0 Pt 17.7 Pt 17.7 6 Q= 11.2 F= 2R3B3L F= 32.0 C= 150 Pe .0 Pv -.2 Vel= 6.0 D= .874 TL= 71.0 .0711 Pf 5.1 Pn 17.5 6 Pt 22.8 6 q= .0 K= .0 ------------------------------------------------------------------------- - L= 33.0 Pt 22.8 Pt 22.8 7 Q= 11.2 F= 3R3L F= 24.0 C= 150 Pe .0 Pv -.2 Vel= 6.0 D= .874 TL= 57.0 .0711 Pf 4.1 Pn 22.6 7 Pt 26.9 7 .0 K= .0 -------------------------------------------------------------------------- L= 6.0 Pt 26.9 Pt 26.9 8 Q= 27.8 F= 1C4R1S1L F= 21.0 C= 150 Pe 2.6 Pv -.6 Vel= 9.4 D= 1.101 TL= 27.0 .125 Pf 3.4 Pn 26.3 8 Pt 32.9 8 q= 5.0 DOME -------------------------------------------------------------------------- L= 5.0 Pt 32.9 Pt 32.9 9 Q= 32.8 F= 1G1B2L F= 10.0 C= 150 Pe 1.7 Pv -1.1 Vel= 12.7 D= 1.025 TL= 15.0 .2405 Pf 3.6 Pn 31.8 9 Pt 38.2 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 3 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 02-28-2012 File: C:\RESDEN43\12-038.RES JOB : MOORE GUEST HOUSE 161 FT FLAT PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 9 q= .0 K= .0 ------------------------------------------------------------------------------- L= 30.0 Pt 38.2 Pt 38.2 10 Q= 32.8 F= 2C F= 2.0 C= 150 Pe .9 Pv -.8 Ve1= 11.0 D= 1.101 TL= 32.0 .1698 Pf 5.4 Pn 37.4 10 Pt 44.6 10 q= .0 K= .0 -------------------------------------------------------------------------- L= 20.0 Pt 44.6 Pt 44.6 11 Q= 32.8 F= 2C F= 4.0 C= 150 Pe 1.3 Pv-1.2 Vel= 13.5 D= .995 TL= 24.0 .2779 Pf 6.7 Pn 43.3 11 Pt 52.6 -------------------------------------------------------------------------- Meter =13.0 12 Q= 32.8 <<< -------------------------------------------------------------------------- -------------------------------------------------------------------------- SOURCE >>> Pt 65.6 E=>45-E1b L=>90-Elb B=>TeeBch R=>TeeRun C=>CouPlg S=>SwgChk G=>GatVlv HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.2 - SUBMITTAL. ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. DATE : 02-28-2012 FILE : C:\RESDEN43\12-038.RES JOB : MOORE GUEST HOUSE 161 FT FLAT PSI FIRE SPRINKLER HYDRAULIC GRAPH 100 90 80 - 70 60- 50 - 40 30 20 10 0 10 15 20 25 ° Supply Curve Static : 75.0 Resid : 74.0 Flow : 31.0 30 35 40 45 50 FLOW - Gpm Demand Curve Avl Pr : 73.9 @ 32 Req Pr : 65.6 @ 32 Pr Cush: 8.3 Copyright: Hydronics Engineering, 2002. 34119 Fremont Bl, Suite 609, Fremont, CA. 94555. (510) 487-9160. Ar ,qCa Fire Suppression & Building Products Technical Services 800-381-93121+1-401-781-8220 www.tyco-fire.com Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor G enera The Series LFII Residential Flat-Plate Concealed Pendent Sprinkler has a 4.9 escrip ion (60,5) K-factor that provides the required residential flow rates at reduced pres- The TYCO RAPID RESPONSE Series sures enabling smaller pipe sizes and ,.- LFII Residential Flat-Plate Concealed water supply requirements. Pendent Sprinklers (TY2524) are decora- This sprinkler has been designed with fr tive fast response fusible solder sprin heat sensitivity and water distribution # kiers designed for use in residential oc characteristics proven to help in the con cupancies such as homes, apartments, trol of residential fires and to improve dormitories and hotels. the chance for occupants to escape or The Cover Plate/Retainer Assembly con be evacuated ceals the sprinkler operating compo- The Series LFII Residential Flat-Plate nents above the ceiling. The flat profile Concealed Pendent Sprinklers are of the Cover Plate provides the optimum shipped with a Disposable Protective aesthetically appealing sprinkler design. Cap. The Protective Cap protects the Additionally, the concealed design of the Series LFII Residential Flat-Plate Con- sprinkler during ceiling installation or finish. After ceiling installation is corn- Technica cealed Pendent Sprinklers provides 1/2 plete, the Protective Cap is removed inch (12,8 mm) vertical adjustment. This and the Cover Plate/Retainer Assem- Data adjustment provides a measure of flex- bly is installed. Removing the Protec- ibility when cutting fixed pipe drops. tive Cap is required for proper sprinkler Approvals The Series LFll Residential Flat-Plate performance. UL and C-UL Listed Concealed Pendent Sprinklers are in- tended for use in the following systems: - per NFPA 13D, wet pipe residential sprinkler systems for one- and two- family dwellings and mobile homes; per NFPA 13R, wet pipe residential sprinkler systems for residential oc- cupancies up to and including four stories in height; and per NFPA 13, wet pipe sprinkler sys- tems for the residential portions of any occupancy. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and/n- stal/ation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. 1E The Series LFII Residential Rat-Plate Concealed Pendent Sprinklers (TY2524) described herein must be installed and maintained in compliance with this doc- ument and with the applicable standards of the National Fire Protection Associa- tion, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The in- stalling contractor or sprinkler manu- facturer should be contacted with any questions. Model/Sprinkler Identification Number SINj TY2524 NSF-61 Certified The Series LFll Residential Flat-Plate Concealed Pendent Sprinklers are only listed with the Series LFII Concealed Cover Plates having a factory-applied finish. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/ps11° (70,6 LPM/bar) Temperature Rating Sprinkler: 150°F (71°C) Cover Plate: 139°F (59°C) Vertical Adjustment 1/2 inch (12,7 mm) Finishes Refer to the Ordering Procedure section. Physical Characteristics Cover Plate/Retainer Assembly: Cover Plate .............Copper Ejection Spring . .. . Stainless Steel Retainer ................Brass Page 1 of 6 OCTOBER 2010 TFP443 TFP443 Page 2 of 6 Horizontal Ceiling Sloped Ceiling Sloped Ceiling Minimum Flowibland Minimum Flow(b1 and Minimum Flowat and Residual Pressure Residual Pressure Residual Pressure Mil) (Maximum 2-inch rise (Greater than 2-inch rise (Greater than 4-inch rise for 12-inch run) up to maximum 4-inch up to maximum 8-inch rise for 12-inch run) rise for 12-inch run) 160°F (71°C) 160°F (71°C) 160°F (71°C) Sprinkler Sprinkler Sprinkler 12'x 12 12 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) I (3,7 m x 3,7 in) (3,7 m) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 14'x 14' 14' 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) I (4,3 m x 4,3 m) (4,3 m) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 16'x 16 16' 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) x 4,9 m) (4,9 m) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 18' x 18' 18' 17 GPM (64,3 LPM) 22 GPM (83,3 LPM) 22 GPM (83,3 LPM) (5,5 m 5,5 m) (5,5 m) 12.0 psi (0,83 bar) 20.2 psi (1,39 bar) 20.2 psi (1,39 bar) 20'x 20' 20' 20 GPM (75,7 LPM) 24 GPM (90,8 LPM) 24 GPM (90,8 LPM) (6,1 m 6,1 m) (6,1 m) 16.7 psi (1,15 bar) 24.0 psi (1,65 bar) 24.0 psi (1,65 bar) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which Hydraulic Design section under the Design Criteria are stated. The Minimum Flow requirement is based on minimum flow in GPM (LPM) from each sprinkler . T h e a s s o c i a t e d r e s i d u a l p r e s s u r e s are calculated using The nominal K-factor. Refer to "Hydraulic Design' in the Design Criteria secti o n f o r d e t a i l s . T14BLEA SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SP R I N K L E R ( T Y 2 5 2 4 ) NFPA 13D AND NFPA 13!? HYDRAULIC DESIGN CRITERIA WET PIPE SYSTEMS Sprinkler/Support Cup Assembly: Body ...................Brass Cap ...................Bronze Saddle ..................Brass Sealing Assembly .......Beryllium Nickel w/ Teflon' Soldered Link Halves ......Nickel Lever ..................Broe Compression Screw .......Brass Deflector ...............Bronze Guide Pin Housing........Bronze Guide Pins .............Bronze Support Cup ..............Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup As- sembly. At this point, the Deflector, sup- ported by the Guide Pins, drops down to its operated position. The Solder Link Element of the Sprinkler/ Support Cup Assembly is comprised of two link halves that are soldered togeth- er with a thin layer of solder. When the rated temperature is reached, the sol- der melts and the two link halves sepa- rate, allowing the sprinkler to activate and flow water. 1 Registered trademark of Dupont Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) are UL and C-UL Listed for installation in ac- cordance with the following criteria. When conditions exist that are outside the scope of the provided criteria, re- fer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that maybe accept- able to the Authority Having Jurisdiction. The Series LFlI Residential Rat-Plate Concealed Pendent Sprinklers must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup can delay sprinkler op- eration in a fire situation. System Type Only wet pipe systems may be utilized. Hydraulic Design Table A provides the minimum required sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required dis- charge from each of the total number of "design sprinklers" as specified in NFPA 130 or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be thefour most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: flow rates given in Table A for NFPA 13D and 13R as a function of tem-perature rating and the maximum al- lowable coverage area minimum discharge of 0.1 GPM/ sq. ft. over the "design area" com- prised of the four most hydraulically demanding sprinklers for actual cov- erage areas protected by the four sprinklers Obstruction To Water Distribution Locate sprinklers in accordance with the obstruction rules of NFPA for residential sprinklers as well as obstruction criteria described within TYCO technical data sheet TFP490. Operational Sensitivity Install sprinklers relative to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprin- klers cannot exceed the length of the coverage area (Table A) being hydrau- lically calculated; for example, a maxi- mum of 12 feet for a 12 ft. x 12 ft. cov- erage area or 20 feet for a 20 ft. x 20 ft. coverage area. TFP443 Page 3 of 6 BODY SEALING (1/2' ('JPT) 0 ASSEMBLY CAP SPRINKLER WRENCHING AREA SADDLE SUPPORT COMPRESSION CUP WITH SCREW ROLL FORMED THREADS LEVER GUIDE PIN SOLDER LINK I ELEMENT GUIDE PIN I I I HOUSING I A I DEFLECTOR I (OPERATED DEFLECTOR I I POSITION) I SPRINKLER/SUPPORT CUP I ASSEMBLY THREAD INTO RETAINER SUPPORT CUP WITH THREAD UNTIL MOUNTING DIMPLES SURFACE IS CD 0 FLUSH WITH EJECTION CEILING SPRING SOLDER COVER PLATE/RETAINER COVER TAB ASSEMBLY PLATE FIGURE 1 FLAT-PLATE CONCEALED PENDENT SPRI N K L E R ( T Y 2 5 2 4 ) ASSEMBLY WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 18 SPRINKLER WRENCH 2-1/2' Uk. SPRINKLER- (83,5 mm) / 1/2' (12,7 mm) FACE OF SUPPORT CUP / 1/2 THREADED SPRINK LER ASSEMBLY NFl ADJUSTMENT FITTING OPERATE 1-7/8'±l/E' / SPRINKLE !i COVER PLATE L (47,6 mm RETNNEF 1/8'GAP ±3,2 mm) 7/8' (,2 rr COVER- SPRINKLER- j I MOUNTING I I RETAINER SUPPORT CUP 3/16' J SURFACE ASSEMBLY ASSEMBLY (4,8 mm) - //>' 3-3/16' DIA. DISPOSABLE (81,0 mm) TIP PROTECTIVE CAP FIGURE 3 PROTECTIVE CAP AND ACTIVATED DEF L E C T O R INSTALLATION DIMENSIONS DEFLECTOR IN OPERATED POSITION TFP443 Page 4 of 6 As long as the protective Cap re- mains in place, the system is con- sidered "Out Of Service' After the ceiling has been com- pleted with the 2-1/2 inch (63 mm) diameter clearance hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and discard the Protective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Screw on the Cover Plate/Retainer Assembly until its flange contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Mounting Cup or the Cover Plate/Retainer As- sembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. The TYCO RAPID RESPONSE Series LFII Residential Fiat-Plate Concealed Pendent Sprinkler (TY2524) must be maintained and serviced in accordance with the following instructions. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it con- trols, obtain permission to shut down the affected fire protection system from the proper authorities and notify all person- nel who may be affected by this action. When properly installed, there is a nomi- nal 1/8 inch (3,2 mm) air gap between the lip of the Cover Plate and the ceil- ing, as shown in Figure 3. This air gap is necessary for proper operation of the sprinkler by allowing heat flow from a fire to pass below, and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling needs repainting after sprinkler installation, exercise care to ensure that the new paint does NOT seal off any of the air gap. Failure to do so may impair sprinkler operation. Absence of a Cover Plate can delay the sprinkler operation in a fire situation. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Exercise care to avoid damage to sprin- klers before, during, and after installa- tion. Never paint, plate, coat, or other- wise alter automatic sprinklers after they leave the factory. Never repaint factory-painted Cover Plates. When necessary, replace cover plates with factory-painted units. Non- factory applied paint can adversely de- lay or prevent sprinkler operation in the event of a fire. Replace sprinklers that: were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. e were modified or over-heated. are leaking or exhibiting visible signs of corrosion. Responsibility lies with owners for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. The TYCO RAPID RESPONSE Series LFII Residential Fiat-Plate Concealed Pendent Sprinklers must be installed in accordance with the following instructions. Damage to the Solder Link Element dur- ing installation can be avoided by han- dling the sprinkler by the Support Cup only; that is, do not apply pressure to the Solder Link Element (Figure V. Obtain a leak-tight 112 inch NPT sprinkler joint by applying a minimum-to-max!- mum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Cover Plate! Retainer Assembly by under- or over- tightening the sprinkler Re-adjust the position of the sprinkler fitting to suit. Install pendent sprinklers in the pendent position, with the center- line of the sprinkler perpendicular to the mounting surface. Remove the Protective Cap, With pipe-thread sealant applied to the pipe threads,. and using the W-Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler! Support Cup Assembly into the fit- ting. The W-Type 18 Wrench ac- cepts a 1/2 inch ratchet drive. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protective Cap helps prevent dam- age to the Deflector and Guide Pins during ceiling installation and/ or during application of the finish coating of the ceiling. TFP443 Page 5 of 6 Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the orig- inal Buyer for ten (10) years against de- fects in material and workmanship when paid for and properly installed and main- tained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFSBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFSBP to be defec- tive shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of Products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete in- formation supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in con- tract, tort, strict liability or under any oth- er legal theory, for incidental, indirect, special or consequential damages, in- cluding but not limited to labor charg- es, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of mer- chantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on fail- ure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any oth- er legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Contact your local distributor for avail- ability. When placing an order, indicate the full product description and Part Number (PIN). Sprinkler/Support Cup Assembly Specify: Series LFII Residential Flat- Plate Concealed Pendent Sprinkler (TY2524), K=4.9, without Cover Plate! Retainer Assembly, PIN 51-114-1-150. Cover Plate/Retainer Assembly Specify: Cover Plate/Retainer Assem- bly with finish (below) for the Series LFII Residential Flat-Plate Concealed Pendent Sprinkler (TY2524), K'r4.9, P/N (below): Chrome ..................P/N 56-201-9-135 Custom ...................P/N 56-201-X-135 Oft White ................P/N 56-201-0-135 Pure White (RAL 9010). ............... P/N 56-201-3-135 Signal White' (SAL 9003) ...............P/N 56-201-4- 1 3 5 Standard White (Grey White) (RAL9002) ................P/N 56-201-5-135 Eastam Hemisphere sates only. Previously known as Bright Whhe. Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact TYCO Customer Service with any questions related to custom orders. Sprinkler Wrench Specify W-Type 18 Sprinkler Wrench, PIN 56-000-1-265. December 20, 2010 Sprinkler 4'j MIC R!XtJT - The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 277-384-5464 Fax: 269-812-1680 Email: techsvcsvikingcorp.con 1. DESCRIPTION Viking Microfase and MicrofastHpe Quick Response Pendent Sprinklers are small, then-nosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K Factors to meet design requirements The special Polyester and Teflon' coatings can be used in decorative applications where colors are desired In addition these coatings have been investigated for installation in corrosive at- mospheres and are clJLus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification forTeflone and Polyester coat- ings as corrosion resistant) 2. LISTINGS AND APPROVALS cliLus Listed: Category VNIV FM Approved Classes 2001, 2002, 2015, and 2017 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984C-PDA . VdS Approved: Certificates G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. Nos. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD2003, 0786CPD40130, and 0786-CPD-40 170 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on page 41d for cULus Listing requirements and refer toApproval Chart 2 and Design Criteria on page 41 f for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for 1 Viking Technical Data may be ~fcooundn use with water working pressures ranging from the minimum 7 psi The Viking Corporation's We (05 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- htlp://www.vikinggroupinc.com. sure (HP) sprinklers can be identified by locating "250" stamped on The Web site may include a more recent the deflector. All other Part Nos. not mentioned above are rated to a edition of this Technical Data Page. maximum 175 psi (12 bar) wwp. . Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.SA. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 066626 and 12282. Brass UNS-C84400 for all other sprinklers. Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 066625, 066665, and 067656. Copper UNS- C 19500 for Sprinkler 12282. Phosphor Bronze UNS-051000, Copper UNS-C19500 or Brass UNS-C26000 for Sprinkler 067206. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 067186, 067206, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Form No. F 081296 Replaces page 41a-f, dated November 16, 2010. (Added FM Approval for sprinkler 067656.) Sprinkler 41b December 20, 21 MICROFAST® AND MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1 6 8 0 E m a i l : t e c h s v c s v i k i n g c o r p . c o ; Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Teflon' Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Ca p-Teflon' Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfaste and MicrofastHPe Quick Response Pendent Sprinklers by first adding the a p p r o p r i a t e s u f f i x f o r t h e s p r i n k l e r fin ish and then the appropriate suffix for the temperature rating to the sprinkler base part n u m b e r . Finish Suffix: Brass =A, ChromeEnloye= F, White Polyester = M-]W, Black Polyester = M-1B, and Black Teflon'= N Temperature Suffix ('F/'C): 135°I57' = A, 155°I68' = B, 175°f79 = 0, 200193° = E, and 286'1341 = G For example, sprinkler VK302 with a 112 thread, Brass finish and a 155 ¶168 °c temperature rating = Part No. 06662BAB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the 'Sprinkler Accessories section of the Viking data b o o k . ) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/6 (available since 2000). Wrench for Coated and/or Recessed Sprinklers: Part No. 12144W/B* (available since 2003 ) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool Part No. 15 9 1 5 ( a v a i l a b l e s i n c e 2 0 1 0 . ) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENC H 1 2 1 4 4 W / B - A '/ ratthel is required (not available from Viking). —Allows use from the floor by attaching a length of V diameter CPVC tubing to the tool Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724,4 (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions; the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the p i p c a p a n d sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler de f l e c t o r , f o r m i n g a u n i f o r m s p r a y p a t t e r n to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Insoection. Testincj and Maintenance requirements. AVAILABILITY The Viking Mici-ofaste and MicrofastHPe Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Protective Sprinkler Flats Cop 1089 Figure 1: Standard Sprinkler Wrench 10896W/B December 20, 2010 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 2 6 9 - 8 1 8 - 1 6 8 0 E m a i l : t e c h s v c s @ v i k i n g c o r p . c o . Ordinary 135 F (57 °C) 100 ¶ (38 C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red intermediate 175 °F (79 °C) 150 °F (65 C) Yellow Intermediate 200 F (93 °C) 150 F (65 °C) Green High 286 F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, ChromeEnloye, White Polyester, Black Polyester, and Black Teflon" Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black Teflon' Footnotes The sprinkler temperature rating is stamped on the deflector. 28ased on NFPA-13 Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3The corrosion-resistant coatings have passed the standard corrosion t e s t r e q u i r e d b y t h e approving agencies indicated in the Approval Charts. These tests cannot and do not represent at possible corrosive environments. Prior to installation, verity through the end-user that the coatings are compat-ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Tellone coatings. I / 1 / Sprinkler 'drench 12144//Ban for / ins-tailing coated and/or recessed penden-t sprinklers q Carefully slide the A with protective caps. wrench sideways -'- around the protective cop, ensuring engage- nent with the sprinkler ai4 1/2 ratchet is required wrench flats, (not available from Viking). Figure 2: Wrench 12144W/B for Coated and/or Recessed Pendent Sp r i n k l e r s Sprinkler MICROFASTe AND. MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS 1-3/4'. (44,5 mm) Installed with a 1-1/2' (38.1 mm) minimum 1-3/4' (44.5 mm) Maximum 1-1/8' (28.6 mm) Minimum December20, 2010 ' p '?flJN¼ L Sprinkler MICRO FAST®.A ND MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, H a s t i n g s M l 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.cc cULus Listing Requirements: Microfaste and MicrofastflPa Quick Response Pendent Sprinklers are cULus Listed as indicated in theApproval Chart for installation in accordance wit the latest edition of NFPA 13 for standard spray sprinklers. - Designed for use in Light and Ordinary Hazard occupancies (exception: sinail orifice sprinklers are limited to Light Hazard where allo w e d b the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard sp r a y p e n d e n t s p r i n k l e r s m u s t b e f o l l o w e d . IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to b e i n s t a l l e d i n a c c o r -dance with the latest edition of Viking technical data, t h e a p p r o p r i a t e s t a n d a r d s o f N F P A , L P C 8 , A P S A D , VdS or other similar organizations, and also with the pro v i s i o n s o f g o v e r n m e n t a l c o d e s , o r d i n a n c e s , a n d s t a n d a r d s , whenever applicable. Ceiling Opening Size: 2-5/16' (58.7 fir,) minimum 2-1/8' 2-1/2' (63.5 mm) maximum (54 nm) i/2 (15 nn) NPT 1 mph 2-1/4' (41 rim) (58 mm) Pendent Sprinkler standard 1/8' surface- Installed with a Microfas± 0666213 (VK302) mounted escutcheon. Model F-i Adjustable Escutcheon Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon L 2-1/8' 54 mm) I Ceiling Opening Size: 2-1/8J 2-5/16' (58.7 mm) minimum (54 nfl) 2-1/2' (63.5 mm) maximum nm 1-1/8' (28.6 mm) (50,8 Minimum ) Maximum J__________ Installed with a Micronatic Model E-1 Recessed Escutcheon Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: SprinkierVK302 Dimensions with the Model E-I and E-2 Recessed Escutcheons Sprinkler 4 1 d December 20, 2 MICRD ID FASTOAN MicrofastHP11 QUICK RESPONSt PENDENT SPRINKLERS - - The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 4 9 0 5 8 Telephone: 269-945-9501 Technical Services: 877-384-5464 F a x : 2 6 9 - 8 1 8 - 1 6 8 0 E m a i l : t e c h s v c s @ v i k i n g c o r p . c o Sprinkler I Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) - - Part No.' [NPT BSP U.S. metric-' Inches mm cULtis4 NYC' VdS LPCB j CE 8. Standard Orifice 066628 VK302 1/2' 15 mm 5.6 80.6 2-1/4' 1 58 1 AIX, B1Y AIX, B1Y A3 A3X, 63Y C3X, E3Y" C3X, E 3 Y ' 3 Large Orifice 06666B VK352 314° 20 mm 8.0 115.2 2-3/8' 60 AIX, B1Y AIX, ElY A3 A3X C311 - 057658 VK352 112' j15 mm 1 8.0 115.2 2-3/8" 1 60 1 AIX, B1Y AIX, B1Y LA3 - - Sr-nail Orifice' 067188' J VK329 1/2° 15 mm 2.8 40.3 2-3/16' 56 AIX, 131Y I AIX, ElY - - - 067208' J VK331 112° 15 mm 42 57 2-1/4' 58 AIX, SlY AIX, B1Y - - - 059328 j V1K331 - 10 mm 1 4.2 57 2-318" 6.0 ,.çj - j 0212 I - Maximum 250 PSI (17 bar) WIN? Standard Orifice Sprinkler Thread Nominal Overall Listings and Approvals' Base SIN ea K-Factor I Length (Refer also to Design Criteria on page 41e) Part No' NPT I BSP U.S. metric2 / Inches 1mm -UL.;; NYC" VdS LPCB / CE 12282 VK317 1 112° 1 15 mm 5.S 80.6 I 2-1/4' 58 A1X,B1Y I AIX - - - Maximum 250 PSI (17 bar) WWP Small Orifice' 12290" VK342 ( 112" 115 mm / 28 J 40.3 1 2-3/16- J 56 1 AIX, SlY I AIX - - - - Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 "P (79 °C), 200 °F (93 °C), Approved Escutcheons and 286 °F (141 "C) Approved Finishes X - Standard surface-mounted escutcheon or B - 135°F (57 °C), 155 "P (68 °C), 175 °F (79 °C), and 200 °F I - Brass, Chrome-Enloy, White the Viking Mia-ofast' Model F-i Adjustable C - 155 °F(68 "C) 175 °F (79 "C), 200 °F (93 °C), and 286 °F Polyeste 3, Black Polyeste', Escutcheon (141 °C) and Black Teflon Y - Standard surface-mounted escutcheon or 0- 135 °F (57 "C) 155°F (68 "C) 175 "P (79 "C) and 286 °F 2- Brass and Chrome-Enlo the Viking Mio-ofast' Model F-i Adjustable (141 °C) 3 - Brass, Chrome-Enloy5, iMilte Escutcheon or recessed with the Viking E - 155 "P (68 °C), 175 "F (79 "C), and 200 °F (93 °C) Polyester7, and Black Polyester7 Micromatic' Model E-i or E-2 Recessed F -155 "F(68 °C), 175°F (79 "C), and 286 "F(141 "C) Escutcheon 0-155 °F(68 °C) - Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. W h e n p r e s s u r e i s m e a s u r e d i n k P a , d i v i d e t h e m e t r i c K - f a c t o r shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and C a n a d a . Accepted for use, City of New York Board of Standards and Appeals C a l e n d a r N u m b e r 2 1 9 - 7 6 - S A . 6 cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. 8 Listings and Approvals limited to Light Hazard Occupancies where all o w e d b y t h e i n s t a l l a t i o n s t a n d a r d s b e i n g a p p l i e d , w i t h h y d r a u l i c a l l y c a l c u l a t e d wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion r e s i s t a n t o r internally galvanized. 'The sprinkler orifice is bushed. '°Acepted for use, City of New York Department of Buildings, MEA N u m b e r 89-92-E, Vol. 15. 11 Ct Certified, Standard EN 12259-1, EC—certificate of conformity 0832-CP D - 2 0 0 1 a n d 0 8 3 2 - C P D - 2 0 0 3 . - CC Certified, Standard EN 12259-1 EC-certificate of conformity 0786-C P D - 4 0 1 3 0 a n d 0 7 8 6 - C P D - 4 0 1 7 0 . 13 I MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED- 1 0 0 8 . Sprinkler4lf December2O,2 MicrofastHP11 QUICK Is -C RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 F a x : 2 6 9 - 8 1 8 - 1 6 8 0 E m a i l : t e c h s v c s @ v i k i n g c o r p . c o Sprinkler SIN Thread Size Nominal K-Factor Overall Length FM Approvals3 N06662B 1 NPT J BSP U.S. metric2 Inches mm (Refer also to Design Criteria below.) Standard Orifice VK302 J 1/2" 115 mm J 5.6 ( 80.6 j 2-1/4' 58 A2X, B2Y Large Orifice j VK352 3/4" 20 mm 8.0 115.2 2-3/8" 60 AiX,ElY VK352 112" 15 mm 8.0 115.2 2-3/8" 60 I AiX, ElY Small Orifice' 06718B6 —F—W329 112 115 mm 2.8 40.3 2-3/16' 56 AIX Approved Escutcheons X -Standard surface-mounted escutcheon or the Viking Approved Temperature Ratings Approved Finishes A - 135 "F (57 °C), 155 "F (68 "C), 175 "F (79 C), I - Brass and Chrome-EnJoy5 Microta5t5 Model F-i Adjustable Escutcheon 200 "F (93 "C), and 286 "F (141 "C) Y - Standard surface-mounted escutcheon or the B - 135 'F (57 'C), 155 'F (68 'C), 175 'F (79 'C), 2- Brass, ChrorneEnloy5, White Polyester, Viking Microfast5 Model F-i Adjustable Escutcheon and 200 'F (93 'C) and Black Polyester5 or recessed with the Viking Mioomatic5 Model B-i or E-2 Recessed Escutcheon Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Methc K-facto," measurement shown is when pressure is measured in B a r . W -ien pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time o f p r i n t i n g . C h e c k w i t h t h e manufacturer for any additional approvals. FM Approved as quick response control mode standard spray Non-storage sprinklers. For s p e c i f i c a p p l i c a t i o n a n d i n s t a l l a t i o n r e q u i r e m e n t s , r e f e r e n c e the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). Other colors are available on request with the same Listings a n d A p p r o v a l s a s t h e s t a n d a r d c o l o r s . 6 The sprinkler orifice is bushed. FM Approval Requirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-storage standard spray pendent sprinklers as indicated in the FM Approval Guidet. For specific application and installation requirements, r e f e r e n c e t h e l a t e s t a p p l i c a b l e F M L o s s P r e v e n t i o n D a t a S h e e t s ( i n c l u d i n g Data Sheets 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, b u t n o t l i m i t e d t o : m i n i m u m w a t e r s u p p l y r e q u i r e m e n t s , hydraulic design, ceiling slope and obstructions, minimum and maxim u m a l l o w a b l e s p a c i n g , a n d d e f l e c t o r d i s t a n c e b e l o w t h e c e i l i n g . NOTE: The FM installation guidelines may differ from cULus and/or NFP A c r i t e r i a . tSprirlklers VK302 and VK352 are also FM Approved as quick r e s p o n s e R a c k S t o r a g e s t a n d a r d s p r a y p e n d e n t s p r i n k l e r s . R e f e r t o t e c h n i c a l d a t a page 131a-e for Intermediate Level In-Rack Sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_09 1699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisio n s o f g o v e r n m e n t a l c o d e s , o r d i n a n c e s , a n d standards, whenever applicable. Form No. F081296 . Replaces page 41a-f, dated November 16, 2010. (Added FM Approval for sprinkler 06765B.)