HomeMy WebLinkAbout7600 SITIO DEL MAR; ; AS1101528/23/24,10:04 AM AS110152 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS110152 Job Address: 7600 SITIO DEL MAR Permit Type: SPRINK Parcel No: 2161602700 Lot #: 0 Reference No.: Status: APPROVED Applied 10/7/2011 Approved: 10/6/2011 Issued: 10/6/2011 PC #: Inspector: Project Title: POOL HOUSE SPRINKLER PLANS FOR LA COSTA VISTA COMMUNITY POOL HOUSE Applicant: SYMONS FIRE PROTECTION SUITE R 1050 PIONEER WAY EL CAJON, CA 619-588-6364 Owner: LA COSTA VISTA L L C 2683 COSTEBELLE DR LA JOLLA CA Fees ($) Adcfl Fees ($) Total ($) Balance ($) 724 0 724 0 about:blank 1/1 YDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. ININEERS : SYMONS FIRE PROTECTION. (619) 588-6364. LICENSE : 682025 DESIGNER : ANGELA ZUMAYA DATE : 01-04-2012 FILE : 11-129-3 JOB NAME : LA COSTA TOWN HOMES - POOL HOUSE 161 FLAT LOCATION : SITIO DEL MAR / CORTE AZUL DESIGN DATA. DESIGN CRITERION: MIN SPR FLOW AREA PER SPRINKLER TOTAL CALCULATED AREA TOTAL SPRINKLERS CALCULATED N F P A 13-R (A441,i) 20 Gpm 400SqFt ITI 800 Sq Ft FLOW DATA. TOTAL SPRINKLER FLOW 40.0 Gpm DOMESTIC DEMAND 0.0 Gpm TOTAL WATER REQUIRED 40.0 Gpm BASE OF RISER NODE: 7 FLOW: 40.0 Gpm PRESSURE: 32.9 Psi r I c4. r i DL AUTHORITY HAVING JURISDICTION : CARLSBAD FIRE DEPARTMENT PHONE : (760) 602-4666 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 1 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 01-04-2012 File: C:\RESDEN43\11-129-3.RES JOB : LA COSTA TOWN HOMES - POOL HOUSE 16'FLAT SOURCE STATIC : 85.0 Psi RESIDUAL : 20.0 Psi FLOW : 1500 Gpm DESIGN I SPRINKLER MANUF : TYCO MODEL : LFII I SPRINKLER Q : .0 Gpm VALVE : 12.0 Psi I SPRINKLER P : .0 Psi METER : 7.0 Psi NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet FACTOR Psi Gpm 1 125.0 ----------------------------------------------------------- 4.9 16.6 20.0 2 125.0 4.9 16.7 20.0 3 125.0 17.9 4 125.0 17.9 5 125.0 21.1 6 125.0 24.5 7 117.0 32.9 8 117.0 37.9 9 113.0 40.8 10 110.0 44.5 11 110.0 45.0 12 110.0 52.0 13 110.0 52.5 14 107.0 SOURCE 71.3 40.0 SPRINKLERS FLOWING : 2 AREA PER SPRINKLER : 400 Sq Ft TOTAL DESIGN AREA : 800 Sq Ft REQUIRED DENSITY : Gpm/Sq Ft COMPUTED DENSITY : .05 Gpm/Sq Ft TOTAL SPRINKLER FLOW : 40.0 Gpm TOTAL DOMESTIC FLOW : Gpm TOTAL WATER REQUIRED : 40.0 Gpm TOTAL SPRINKLER PRESS : 52.3 Psi WATER METER LOSS : 7.0 Psi VALVE FIXED LOSS : 12.0 Psi Copyright (2002) SUPPLY PRESS AVAILABLE : 84.9 Psi by DEMAND PRESS REQUIRED : 71.3 Psi Hydronics Engineering PRESSURE CUSHION : 13.6 Psi 34119 Fremont Bl, Suite 609 Fremont, Ca., 94555 MAXIMUM VELOCITY : 16.5 F/S (510) 487-9160 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 2 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 01-04-2012 File: C:\RESDEN43\11-129-3.RES JOB : LA COSTA TOWN HOMES - POOL HOUSE 16'FLAT PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 1 q= 20.0 K= ------------------------------------------------------------------------------- 4.9 L= 6.0 Pt 16.6 Pt 16.6 1 Q= 20.0 F= 1B1L F= 12.0 C= 150 Pe .0 Pv -.3 Vel= 6.7 D= 1.101 TL= 18.0 .068 Pf 1.2 Pn 16.3 4 Pt 17.9 2 q= 20.0 K= 4.9 -------------------------------------------------------------------------- L= 5.0 Pt 16.7 Pt 16.7 2 Q= 20.0 F= 1L1B F= 12.0 C= 150 Pe .0 Pv -.3 Vel= 6.7 D= 1.101 TL= 17.0 .0682 Pf 1.2 Pn 16.4 3 Pt 17.9 3 q= .0 K= .0 -------------------------------------------------------------------------- L= 46.0 Pt 17.9 Pt 17.9 3 Q= .3 F= 2B4R F= 14.0 C= 150 Fe .0 Pv .0 Vel= .1 D= 1.101 TL= 60.0 .0 Pf .0 Pn 17.9 4 Pt 17.9 4 q= .0 K= .0 -------------------------------------------------------------------------- L= 29.0 Pt 17.9 Pt 17.9 4 Q= 19.7 F= 2B2R1L F= 19.0 C= 150 Fe .0 Pv -.3 Vel= 6.6 D= 1.101 TL= 48.0 .066 Pf 3.2 Pn 17.6 5 Pt 21.1 3 q= .0 K= .0 -------------------------------------------------------------------------- L= 33.0 Pt 17.9 Pt 17.9 5 Q= 20.4 F= 232R F= 12.0 C= 150 Fe .0 Pv -.3 Vel= 6.9 D= 1.101 TL= 45.0 .0703 Pf 3.2 Fn 17.6 5 Ft 21.1 5 q= .0 K= .0 -------------------------------------------------------------------------- L= 2.0 Pt 21.1 Pt 21.1 6 Q= 40.0 F= 1ML F= 12.0 C= 150 Fe .0 Pv -1.2 Vel= 13.5 D= 1.101 TL= 14.0 .2455 Pf 3.4 Fn 19.8 6 Ft 24.5 6 q= .0 K= .0 -------------------------------------------------------------------------- L= 6.0 Pt 24.5 Pt 24.5 7 Q= 40.0 F= 4R1S1C F= 14.0 C= 150 Fe 3.5 Pv -1.2 Vel= 13.5 D= 1.101 TL= 20.0 .2455 Pf 4.9 Pn 23.3 7 Pt 32.9 7 Q= 40.0 -------------------------------------------------------------------------- Ft 32.9 ALV FIXED PRESSURE LOSS Valve 5.0 8 Pt 37.9 8 q= .0 K= .0 -------------------------------------------------------------------------- L= 5.0 Pt 37.9 Pt 37.9 9 Q= 40.0 F= 2L1B1G F= 17.0 C= 150 Fe 1.7 Pv -.4 Vel= 7.2 D= 1.505 TL= 22.0 .0536 Pf 1.2 Pn 37.6 9 Ft 40.8 9 q= .0 K= .0 -------------------------------------------------------------------------- L= 140.0 Ft 40.8 Pt 40.8 10 Q= 40.0 F= 6C3L F= 39.0 C= 150 Pe 1.3 Pv -.1 Vel= 4.1 D= 2.003 TL= 179.0 .0133 Pf 2.4 Pn 40.7 10 Pt 44.5 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 3 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 01-04-2012 File: C:\RESDEN43\11-129-3.RES JOB : LA COSTA TOWN HOMES - POOL HOUSE 16'FLAT PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 10 q= .0 K= .0 ------------------------------------------------------------------------------- L= 5.0 Pt 44.5 Pt 44.5 11 Q= 40.0 F= 1C1L F= 4.0 C= 150 Pe .0 Pv -.4 Vel= 7.2 D= 1.505 TL= 9.0 .0536 Pf .5 Pn 44.2 11 Pt 45.0 11 Q= 40.0 -------------------------------------------------------------------------- Pt 45.0 DDC FIXED PRESSURE LOSS Valve 7.0 12 Pt 52.0 12 q= .0 K= .0 -------------------------------------------------------------------------- L= 5.0 Pt 52.0 Pt 52.0 13 Q= 40.0 F= 1C1L F= 4.0 C= 150 Pe .0 Pv -.4 Vel= 7.2 D= 1.505 TL= 9.0 .0536 Pf .5 Pn 51.7 13 Pt 52.5 13 q= .0 K= .0 -------------------------------------------------------------------------- L= 20.0 Pt 52.5 Pt 52.5 14 Q= 40.0 F= 2L1C F= 6.0 C= 150 Pe 1.3 Pv -1.8 Vel= 16.5 D= .995 TL= 26.0 .402 Pf 10.5 Pn 50.7 14 -------------------------------------------------------------------------- Pt 64.3 Meter = 7.0 15 Q= 40.0 <<< -------------------------------------------------------------------------- -------------------------------------------------------------------------- SOURCE >>> Pt 71.3 E=>45-E1b L=>90-E1b B=>TeeBch R=>TeeRun C=>CouPlg S=>SwgChk G=>GatVlv HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.2 - SUBMITTAL. ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. DATE : 01-04-2012 FILE : C:\RESDEN43\11-129-3.RES JOB : LA COSTA TOWN HONES - POOL HOUSE 16'FLAT PSI FIRE SPRINKLER HYDRAULIC GRAPH 100 90 80 70 60 50 40 30 20 10 0 300 450 600 750 900 0 Supply Curve Static : 85.0 Resid : 20.0 Flow : 1500.0 1050 1200 1350 1500 FLOW - Gpm Demand Curve Avl Pr : 84.9 @ 40 Req Pr : 71.3 @ 40 Pr Cush: 13.6 Copyright: Hydronics Engineering, 2002. 34119 Fremont Bl, Suite 609, Fremont, CA. 94555. (510) 487-9160. tqCJ7 Fire Suppression & Building Products apidesponse Technical Services 800-381-93121 +1-401-781-8220 HOME FIRE SPRINKLER SYSTEM - www.tyco-fire.com Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 49 K-Factor General Description The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) are decora- tive, fast response, fusible solder sprin- klers designed for use in residential oc- cupancies such as homes, apartments, dormitories, and hotels. The Cover Plate/Retainer Assembly con-: ceals the sprinkler operating compo- nents above the ceiling. The flat profile of the Cover Plate provides the optimum aesthetically appealing sprinkler design. Additionally, the concealed design of the Series LFII Residential Flat-Plate Con- cealed Pendent Sprinklers provides 1/2 inch (12,8 mm) vertical adjustment. This adjustment provides a measure of flex- ibility when cutting fixed pipe drops. The Series LFII Residential Flat-Plate Concealed Perident Sprinklers are in- tended for use in the following systems: per NFPA 13D, wet pipe residential sprinkler systems for one- and two- family dwellings and mobile homes; per NFPA 13R, wet pipe residential sprinkler systems for residential oc- cupancies up to and including four stories in height; and per NFPA 13, wet pipe sprinkler sys- tems for the residential portions of any occupancy. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. The Series LFII Residential Flat-Plate Concealed Pendent Sprinkler has a 4.9 (60,5) K-factor that provides the required residential flow rates at reduced pres- sures, enabling smaller pipe sizes and water supply requirements. This sprinkler has been designed with heat sensitivity and water distribution characteristics proven to help in the con- trol of residential fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap protects the sprinkler during ceiling installation or finish. After ceiling installation is com- plete, the Protective Cap is removed and the Cover Plate/Retainer Assem- bly is installed. Removing the Protec- tive Cap is required for proper sprinkler performance. Lu.1g(.q The Series LFll Residential Rat-Plate Concealed Pendent Sprinklers (7-Y2524) described herein must be installed and maintained in compliance with this doc- ument and with the applicable standards of the National Fire Protection Associa- tion, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The in- stalling contractor or sprinkler manu- facturer should be contacted with any questions. Model/Sprinkler• Identification Number (SIN) TY2524 Technical Data Approvals UL and C-UL Listed NSF-61 Certified The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are only listed with the Series LFII Concealed Cover Plates having a factory-applied finish. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/ps112 (70,6 LPM/bar) Temperature Rating Sprinkler: 160°F (71°C) Cover Plate: 139°F (59°C) Vertical Adjustment 1/2 inch (12,7 mm) Finishes Refer to the Ordering Procedure section. Physical Characteristics Cover Plate/Retainer Assembly: Cover Plate .............Copper Ejection Spring .... Stainless Steel Retainer ................Brass Page 1 of 6 OCTOBER 2010 TFP443 TFP443 Page 2 of 6 Horizontal Ceiling Sloped Ceiling Sloped Ceiling Minimum Flowibi and Minimum Flowcb) and Minimum Flow(') and Residual Pressure Residual Pressure Residual Pressure Maximum Maximum (Maximum 2-inch rise (Greater than 2-inch rise (Greater than 4-inch rise Coverage Spacing for 12-inch run) up to maximum 4-inch up to maximum 8-inch Area (') rise for 12-inch run) rise for 12-inch run) 160"F (71°C) 160°F (71°C) 160°F (71°C) Sprinkler Sprinkler Sprinkler 12'x 12 12 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) (3,7 mx 3,7 m) (3,7 m) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 14'x 14' 14' 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) (4,3 m x 4,3 m) (4,3 m) 7.0 psi (0,48 bar) . 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 16'x 16' 16' 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) (4,9 mx 4,9 m) (4,9 m) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 18' x 18' 18' 17 GPM (64,3 LPM) 22 GPM (83,3 LPM) 22 GPM (83,3 LPM) (5,5 m x5,5 m) (5,5 m) 12.0 psi (0,83 bar) 20.2 psi (1,39 bar) 20.2 psi (1,39 bar) 20'x 20' 20' 20 GPM (75,7 LPM) 24 GPM (90,8 LPM) 24 GPM (90,8 LPM) (6,1 mx 6,1 m) I (6,1 m) 16.7 psi (1,15 bar) 24.0 psi (1,65 bar) 24.0 psi (1,65 bar) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which Hydraulic Design section under the Design Criteria are stated. The Minimum Flow requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to'Hydraulic Design" in the Design Criteria section for details. TABLE A SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA WET PIPE SYSTEMS Sprinkler/Support Cup Assembly: Body ...................Brass Cap ...................Bronze Saddle ..................Brass Sealing Assembly .......Beryllium Nickel w/Teflon' Soldered Link Halves ......Nickel Lever ..................Bronze Compression Screw .......Brass Deflector ................Bronze Guide Pin Housing........Bronze Guide Pins .............Bronze Support Cup ..............Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup As- sembly. At this point, the Deflector, sup- ported by the Guide Pins, drops down to its operated position. The Solder Link Element of the Sprinkler! Support Cup Assembly is comprised of two link halves that are soldered togeth- er with a thin layer of solder. When the rated temperature is reached, the sol- der melts and the two link halves sepa- rate, allowing the sprinkler to activate and flow water. 1 Registered trademark of Dupont Design Criteria The TYCO RAPID RESPONSE Series LFll Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) are UL and C-UL Listed for installation in ac- cordance with the following criteria. When conditions exist that are outside the scope of the provided criteria, re- fer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the Authority Having Jurisdiction. The Series LFII Residential Rat-Plate Concealed Pendent Sprinklers must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup can delay sprinkler op- eration in a fire situation. System Type Only wet pipe systems may be utilized. Hydraulic Design Table A provides the minimum required sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required dis- charge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: flow rates given in Table A for NFPA 13D and 13R as a function of tem- perature rating and the maximum al- lowable coverage area minimum discharge of 0.1 6PM/ sq. ft. over the "design area" com- prised of the four most hydraulically demanding sprinklers for actual cov- erage areas protected by the four sprinklers Obstruction To Water Distribution Locate sprinklers in accordance with the obstruction rules of NFPA for residential sprinklers as well as obstruction criteria described within TYCO technical data sheet TFP490. Operational Sensitivity Install sprinklers relative to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprin- klers cannot exceed the length of the coverage area (Table A) being hydrau- lically calculated; for example, a maxi- mum of 12 feet for a 12 ft. x 12 ft. cov- erage area or 20 feet for a 20 ft. x 20 ft. coverage area. 2-1/2' DIA. SPRINKLER- 1/2' (12,7 mm) FACE OF SUPPORT CUP 1/2 THREADED SPRINKLER ASSEMBLY NPT ADJUSTMENT / FITTING OPERATE / SPRINKLE I 1-7/8±1/8' COVER I- (47,6 mm PLATE 1/8 GAP ±3,2 mm) RETAINEF (3,2 mm) MR COVER- SPRINKLER- MOUNTING 7/8" (22,2 rr RETAINER SUPPORT CUP J SURFACE ______________ _______________ 1-1/8" (28,6 ASSEMBLY ASSEMBLY3/16' I (4,8mm) \ 3-3/16' DIA. I DISPOSABLE ,,,/;X/ (81,0 mm) I Tip PROTECTIVE CAP DEFLECTOR IN OPERATED POSITION TFP443 Page 3 of 6 BODY SEALING (1/2 NPT) ASSEMBLY CAP SPRINKLER WRENCHING AREA SADDLE SUPPORT COMPRESSION CUP WITH SCREW ROLL FORMED THREADS LEVER GUIDE PIN I SOLDER LINK I ELEMENT I GUIDE PIN HOUSING I I I J DEFLECTOR L j (OPERATED DEFLECTOR POSITION) SPRINKLER/SUPPORT CUP I I ASSEMBLY I THREAD INTO I RETAINER SUPPORT CUP THREAD UNTIL MOUNTING SURFACE IS MPLES FLUSH WITH 0 CEILING RING ______________________L 'EJECTION jo SOLDER COVER PLATRETNER COVER TAB ASSEMBLY PLATE FIGURE 1 FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) ASSEMBLY WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 18 SPRINKLER WRENCH FIGURE 3 PROTECTIVE CAP AND ACTIVATED DEFLECTOR INSTALLATION DIMENSIONS TFP443 Page 4 of 6 Installation The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers must be installed in accordance with the following instructions. Damage to the Solder Link Element dur- ing installation can be avoided by han- dling the sprinkler by the Support Cup only; that is, do not apply pressure to the Solder Link Element (Figure 1). Obtain a leak-tight 1/2 inch NPT sprinkler joint by applying a minimum-to-maxi- mum torque of 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Cover Plate! Retainer Assembly by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Install pendent sprinklers in the pendent position, with the center- line of the sprinkler perpendicular to the mounting surface. Remove the Protective Cap. With pipe-thread sealant applied to the pipe threads,. and using the W-Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler! Support Cup Assembly into the fit- ting. The W-Type 18 Wrench ac- cepts a 1/2 inch ratchet drive. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protective Cap helps prevent dam- age to the Deflector and Guide Pins during ceiling installation and/ or during application of the finish coating of the ceiling. As long as the protective Cap re- mains in place, the system is con- sidered 'Out Of Service". After the ceiling has been corn- diameter clearance hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and discard the Protective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Screw on the Cover Plate/Retainer Assembly until its flange contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Mounting Cup or the Cover Plate/Retainer As- sembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The TYCO RAPID RESPONSE Series LFll Residential Flat-Plate Concealed Pendent Sprinkler (TY2524) must be maintained and serviced in accordance with the following instructions. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it con- trols, obtain permission to shut down the affected fire protection system from the proper authorities and notify all person- nel who maybe affected by this action. When properly installed, there is a nomi- nal 1/8 inch (3,2 mm) air gap between the lip of the Cover Plate and the ceil- ing, as shown in Figure 3. This air gap is necessary for proper operation of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling needs repainting after sprinkler installation, exercise care to ensure that the new paint does NOT seal off any of the air gap. Failure to do so may impair sprinkler operation. Absence of a Cover Plate can delay the sprinkler operation in a fire situation. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Exercise care to avoid damage to sprin- klers before, during, and after installa- tIGA other- wise alter automatic sprinklers after they leave the factory. Never repaint factory-painted Cover Plates. When necessary, replace cover plates with factory-painted units. Non- factory applied paint can adversely de- lay or prevent sprinkler operation in the event of afire. Replace sprinklers that: were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. were modified or over-heated. are leaking or exhibiting visible signs of corrosion. Responsibility lies with owners for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. TFP443 Page 5 of 6 Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the orig- inal Buyer for ten (10) years against de- fects in material and workmanship when paid for and properly installed and main- tained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFSBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFSBP to be defec- tive shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete in- formation supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in con- tract, tort, strict liability or under any oth- er legal theory, for incidental, indirect, special or consequential damages, in- cluding but not limited to labor charg- es, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied. including warranties of mer- chantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy forclaims based on fail- ure of or defect in products, materials or components, whether the claim is made iftcontracUotLsthcflabilityor.any0th- er legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering ainr Contact your local distributor for avail- ability. When placing an order, indicate the full product description and Part Number (P/N). Sprinkler/Support Cup Assembly Specify: Series LFII Residential Flat- Plate Concealed Pendent Sprinkler (1Y2524), K=4.9, without Cover Plate! Retainer Assembly, P/N 51-114-1-160. Cover Plate/Retainer Assembly Specify: Cover Plate/Retainer Assem- bly with finish (below) for the Series LFII Residential Flat-Plate Concealed Pendent Sprinkler (TY2524), K=4.9, P/N (below): Chrome ..................P/N 56-201-9-135 Custom ...................P/N 56-201-X-135 Off White ................P/N 56-201-0-135 Pure White (RAL 9010)................P/N 56-201-3-135 Signal White * (nAL 9003) ...............P/N 56-201-4-135 Standard White (Grey White) (RAL9002)................P/N 56-201-5-135 Eastern Hemisphere sales only. Previously known as Bright White. Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact TYCO Customer Service with any questions related to custom orders. Sprinkler Wrench Specify W-Type 18 Sprinkler Wrench, P/N 56-000-1-265. December 20, 2010 Sprinkler 41 a ____________________ MICROFAST® AND _____ ____ MicrofastHP® QUICK N1KI _ _____________________ RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Microfast® and MicrofastHP© Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, 2015, and 2017 NYC Approved: Calendar Number 219-76-SA and MbA 89-92-h, Volume 16 ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificates G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. Nos. 096e103 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and 0786-CPD-40170 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on page 41d for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria on page 41f for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for Viking Technical Data may be found on use with water working pressures ranging from the minimum 7 psi The Viking Corporation's Web site at (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- http://www.vikinggroupinc.com. sure (HP) sprinklers can be identified by locating "250" stamped on The Web site may include a more recent the deflector. All other Part Nos. not mentioned above are rated to a edition of this Technical Data Page. maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal. K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 06662B and 12282. Brass UNS-C84400 for all other sprinklers. Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, and 06765B. Copper UNS- C19500 for Sprinkler 12282. Phosphor Bronze UNS-051000, Copper UNS-019500 or Brass UNS-C26000 for Sprinkler 06720B. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B. and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Form No. F_081296 Replaces page 41a-f, dated November 16, 2010. (Added FM Approval for sprinkler 06765B.) Sprinkler 41b December 20, 2010 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°/57" = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141" = 0 For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 066628AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Coated and/or Recessed Sprinklers: Part No. 12144W/B* (available since 2003) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. *A 1/2" ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate N FPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Wrench The Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Vikings current list price schedule or contact Viking directly. Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 10896W/B - I•tIPtJ t - I The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprink ler Temperature Sprinkler Nominal 11axium Ambit rn en Classification Temperature Rating' Bulb Color Ceiling Temperature Ordinary 135°F (57 °C) 100 °F(38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black Teflon® Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These. tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. lm~ Sprinkler Wrench 12144W/B®® for installing coated and/or recessed endent sprinklers H Carefully slide the th protective caps. - wrench sideways around the protective cap, ensuring engage— ment with the sprinkler A 1/2 ratchet is required wrench flats, not available from Viking). Figure 2: Wrench 12144W/B for Coated andlor Recessed Pendent Sprinklers .Sprinkler 41d December 20, 2010 _____________________ MICROFAST® AND MicrofastHP® QUICK N IKI NG RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com I - Microfast and MjcrofastHP Quick Response Pendent Sprinklers JmLm)17PSN12.br)WWP Sprinkler Thread Size1 Nominal f Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.' NPT BSP U.S. metric2 Inches mm cULus4 NYC' VdS LPCB J CE Standard Orifice 06662B VK302 1/2" 115 mm j 5.6 J 80.6 2-1/4" 1 58 1 AiX, BIY I AiX, 131Y 1. A3 A3X, 133Y C3X, E3Y11 C3X, E3Y13 Large Orifice 06666B VK352 3/4" 20 mm 8.0 115.2 2-3/8" 60 AiX, B1Y AiX, B1Y _.. A3X C31' -- 06765B VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 1 AiX, BiY AiX, 131Y -- Small Orifice' 06718B9 VK329 112" 15 mm 2.8 40.3 2-3/16" 56 AiX, B1Y AiX, B1Y -- -- -- - 06720B9 VK331 1/2" 15 mm 4.2 57 2-114" 58 AiX, B1Y AiX, B1Y - - — -- 96932B VK331 -- 10 mm 4.2 57 2-3/8" 60 - -- A3 -- G212 -- Maxim urn 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S. metric' Inches mm cULus4 NYC'- VdS LPCB CE 12282 VK317 I 1/2" 15 mm 5.6 80.6 2-1/4" 58 AiX, 131Y AIX — - -- -- Maxim urn 250 PSI (17 bar) WWP Small Orifice' 1229010 1 VK342 1 1/2" 115 mm 1 2.8 1 40.3 2-3/16" 1 56 J AiX, B1Y I AiX -- -- -- -- Approved Temperature Ratings A- 135 °F(57 °C), 155 °F(68 "C), 175 °F(79 °C),200 "F (93 °C), Approved Escutcheons and 286 "F (141 °C) Approved Finishes X - Standard surface-mounted escutcheon or B - 135°F (57 °C), 155 °F (68 °C), 175 °F (79 "C), and 200 °F 1 - Brass, Chrome-Enloy6, White the Viking Microfast' Model F-i Adjustable (93 C) Polyester67 Black Polyester67, Escutcheon C- 155 °F (68 °C), 175 "F (79 °C), 200 "F (93 °C), and 286 °F an ac Teflon (141 °c) Y - Standard surface-mounted escutcheon or D - 135 "F (57 °C), 155°F (68 "C), 175 "F (79 "C), and 286 °F 2 - Brass and Chrome-EnloyO the Viking Microfaste Model F-i Adjustable (141 °C) 3 - Brass, Chrome-Enloy0', White Escutcheon or recessed with the Viking E - 155 "F (68 °C), 175 "F (79 °C), and 200 "F (93 "C) Polyester', and Black Polyester7 Micromatic Model E-i or E-2 Recessed F - 155 °F (6 °C), 175 °F (79 "C), and 286 °F (141 "C) Escutcheon G - 155 "F (68 °C) Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 6 cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. 8 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. ° The sprinkler orifice is bushed. '°Acçepted for use, City of New York Department of Buildings, MEA Number 89-92-F, Vol. 16. 11 Ct Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 12 (•( Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. 13 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. Installed with a standard 1/8' surface- mounted escutcheon, 1/2' (15 niii) NPT I r 1-5/8' (41 inn) Pendent Sprinkler 06662B (VK302) 1-3/4' (44.5 mm) t VM~i2' Il I (38,1 mm) (50.8mm) \IK I mum Maximum Installed with a Microfast Model F-i Adjustable Escutcheon 1-3/4' (44,5 mm) Maximum 1-1/8' (28.6 mm) Minimum December 20, 2010 Sprinkler 41 e I MICROFAST® AND I MicrofastHP® QUICK I NKI NG ___________________ RESPONSE PENDENT I SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESIGN CRITERIA UL H tefcF tc 4J I 1 j 4 H cULus Listing Requirements: Microfast and MicrofastHP0 Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size 2-5/16' (58,7 mm) minimum j 2-1/8' 2-1/2' (63,5 in) n'IXimUfl (54 ) Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 2-1/8' Ceiling .Opening Size: 2-1/8' (54 mm) 2-5/16' (58.7 mm) minimum (54 mm) 2-1/2' (63.5 mm) maximum (50.8 mm) Maximum 1-1/8" (28.6 rim) Minimum Installed with a Micromatic Installed with a thread on Model C-I Recessed Escutcheon Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-I and E-2 Recessed Escutcheons Sprinkler 411 December 20, 2010 \ _____ MICROFAST® AND MicrofastHP® QUICK OKlNG RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) KEY Mic ofast Quick Response Pendent Sprinklers I Thread Size Nominal K-Factor Overall Length FM Approvals3 Sprinkler Base Part No.' SIN (Refer also to Design Criteria below.) NPT BSP U.S. metric2 Inches mm Standard Orifice 06662B VK302 1/2' 15 mm 5.6 80.6 1 2-1/4" 58 A2X, 132Y Large Orifice 06666B VK352 3/4" 20 mm_J 8.0 115.2 2-3/8' 60 AiX, B1Y 067658 VK352 1/2" 15 mm 8.0 _115.2 _2-3/8" _60 _A1X,B1Y Small Orifice' 06718135 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 AiX Approved Escutcheons Approved Temperature Ratings Approved Finishes X - Standard surface-mounted escutcheon or the Viking A - 135 F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 1 - Brass and Chrome-Enloy® Microfast Model F-i Adjustable Escutcheon 200 "F (93 °C), and 286 "F (141 °C) , 2-Brass,Chrome-Enlo,WhitePolyester, Y - Standard surface-mounted escutcheon or the °F °C), °F °C), a -135 (57 155 (68 175°F (79 °C). and Black Polyester' Viking Microfast' Model F-i Adjustable Escutcheon °F °C) and 200 (93 or recessed with the Viking Micromatic5' Model E-1 or E-2 Recessed Escutcheon Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. FM Approved as quick response control mode standard spray Non-storage sprinklers. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). Other colors are available on request with the same Listings and Approvals as the standard colors. The sprinkler orifice is bushed. LEGNCPITERL ___F1'i - - - - - FM ApprovalRequirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-storage standard spray pendent sprinklers as indicated in the FM Approval Guidet. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheets 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. tSprinklers VK302 and VK352 are also FM Approved as quick response Rack Storage standard spray pendent sprinklers. Refer to technical data page 131a-e for Intermediate Level In-Rack Sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_081296 Replaces page 41a-f, dated November 16, 2010. (Added FM Approval for sprinkler 06765B.) DIMENSIONS & WEIGHTS UNION LESS LESS WITH SIZE A A BALL B BALL C F) F F ( PMI PAIl 3/4 11 1/4 12 1/21 7 11/2 3 1/2T 3 15 5 7 1 13 133141 7 1 1/2 3 3 1/2 3 173/4 8 12 11/4 15 1/2 18 1/2 109/16 2 31/2 41/241/2211/2 16 22 T 1/2 17 1/8 19 1/8 10 9/16 2 3 1/2 41/2 4 1/2 223/4 16 22 2 181/4 20 109/16 2 3 1/2 4 112 4 1/2 251/8 16 28 Mij, B ackflow Specialties (800) 66BKFL0 (I 19) 527-2525 Fax: (619) 527-2527 rmericwzback/low.co,n WILKINS a AM. company Model 950XL Double Check Valve Assembly 3/4" to 2" FEATURES Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI 81.20.1 OPTIONS U - with full port QT ball valves (standard) U L - less ball valves U U - with union ball valves U S - with bronze "Y" type strainer U TCU with test cocks vertical" up U V - with union swivel elbows (3/4" & 1") U OSY - with OS & Y gate valves U FDC - with fire hydrant connection (2" only) U FT - with integral male 450 flare SAE test fitting ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model WXTP) U QT-SET Quick Test Fitting Set MATERIALS Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Internals Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrile (FDA approved) Polymers NorylTM, NSF Listed Springs Stainless steel, 300 series --------------- TIIii1II,I STANDARDS COMPLIANCE (All Horizontal approved. Vertical approved as shown below.) ASSE® Listed 1015 (vertical 3/4", 11/4", 11/2" & 2") IAPMO® Listed (vertical 11/4"-2") CSA® Listed (vertical 3/4", 1 1/4", 1 1/2" & 2") AWWA Compliant C51 0 (vertical 3/4") UL® Classified (less shut-off valves only) C-UL® Classified (less shut-off valves only) USC FCCC & HR (vertical 3/4") City of Los Angeles Approved (verticall 1/4-2") APPLICATION Designed to protect potable water lines against back- siphonage and backpressure from polluted (non-health- hazard) water. FLOW CURVES TYPICAL INSTALLATION Local codes govern installation requirements. Assembly should be mounted at least 12" and no more than 30" above adequate drains, with sufficient clearance for testing and maintenance. No part of the unit may be submerged. Wkir twptu,i,, Pjchwell, SI tqca Fire Suppression & Building Products Technical Services 800-381-9312 I +1-401-781-8220 www.tyco-flre.com ft rapid response® HOME FIRE SPRINKLER SYSTEM Model RSV-1 Residential Shut-Off Valve 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description The TYCO RAPID RESPONSE Model RSV-1 Residential Shut-Off Valves are intended for use in dual-purpose residential water supply piping that serves both domestic and residential fire protection sprinkler system needs. The 1-Inch (DN25) Valve is intended for NFPA 13D system needs, whereas the 2-Inch (DN50) Valve is intended for systems designed in accordance with either NFPA 13D or NFPA 13R. When a fire sprinkler operates, the Model RSV-1 Residential Shut-Off Valve automatically shuts off water flow to the domestic system and di- verts the available water supply to the fire sprinkler system. Consequently, when the Model RSV-1 Valve is uti- lized, the system designer does not need to add the domestic flow de- mand to the fire sprinkler system flow demand, as would otherwise be re- quired by NFPA 13R. Consider use of the Model RSV-1 Residential Shut-Off Valve when either the water supply cannot adequately provide for both the domestic design demand and the fire sprinkler flow de- mand, or it is necessary to increase the effectiveness of the fire sprinkler system by automatically shutting off the domestic flow. The Model RSV-1 Residential Shut- Off Valve maximizes the effective use of an existing water supply. Therefore, in areas with limited water supplies, it may eliminate the need to add costly pumps, pressurized reservoirs, or elec- trically operated domestic shut-off valves. The Model RSV-1 Valve has a built-in check valve in the fire sprinkler system outlet that eliminates the need for a separate check valve. Also, the Model RSV-1 Valve automatically re- sets, thereby eliminating the need for valve disassembly after a fire sprinkler system test or operation. NOTICE The Model RSV-1 Residential Shut-Off Valves described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the integrity of this device. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Technical Data Approvals The 1-Inch (DN25) Model RSV-1 Resi- dential Shut-Off Valve is UL and C-UL Listed and NSF-61 Annex G Approved. It is suitable for use in water supply arrangements for residential fire sprin- kler systems designed per NFPA 13D. The 2-Inch (DN50) Model RSV-1 Resi- dential Shut-Off Valve is UL and C-UL Listed and NSF-61 Annex G Approved. It is suitable for use in water supply arrangements for residential fire sprin- kler systems designed per NFPA 13D or 13R. Maximum Pressure 175 psi (12,1 bar) Weight 1-Inch (DN25): 11 lbs. (5 kg) 2-Inch (DN50): 29 lbs. (11 kg) Pressure Loss Refer to Figures 7 and 8. Patents 2-Inch (DN50) Model RSV-1 Valve: Patent Pending r' Physical Characteristics Refer to Figures 3 and 4. 1-Inch (DN25) Valve Body ..............Copper Alloy Top and Bottom Cover .......Copper Alloy Upper Cap...............Brass Bottom Seal ............. .Brass Piston..........Glass Reinforced Polyphenylene Oxide Differential Ring ...........Glass Reinforced Polyphenylene Oxide Sleeve .........Glass Reinforced Polyphenylene Oxide Upper and Lower Seals..............EPDM 0-Rings ................Buna-N Piston Spring......Stainless Steel Piston Screws .....Stainless Steel Cap Screw........Stainless Steel 2-Inch (DN50) Valve Body and Cover..............Copper Alloy Piston Insert ........Copper Alloy Bottom Seal.........Copper Alloy Piston Cover . . . . Glass Reinforced Polyphenylene Oxide Insert Sleeve . . . . Glass Reinforced Polyphenylene Oxide Piston Seal...............EPDM 0-Rings .................EPDM Piston Spring......Stainless Steel Piston Nut ........Stainless Steel Retainer Ring......Stainless Steel Page 1 of 8 DECEMBER 2010 TFP980 TFP98O Page 2 of 8 2-Inch (DN50) Valve In order for the 2-Inch (DNSO) Model RSV-1 Valve to operate automati- cally at sprinkler activation, the fire sprinkler system from the water supply main to the most hydrauli- cally remote sprinkler must be de- signed to provide a minimum single sprinkler flow of 8 GPM (30,5 LPM) when the water supply pressure at the water supply main is at its mini- mum expected value. The minimum single sprinkler flow rate of 8 GPM (30,5 LPM), required for use with the 2-Inch (DN50) Model RSV-1 Valve, does not take precedence over any more hydrau- lically demanding single sprinkler flow rate specified for the residential sprinklers in use. FIRE SPRINKLER AUTOMATIC FIRE SPRINKLERS SYSTEM PRESSURE GAUGE DRAIN AND FLOW TEST CONNECTION ___- WATERFLOW DETECTOR (FIRE ALARM) ALARM TEST CONNECTION MODEL RSV-1 TO DOMESTIC RESIDENTIAL SHUT-OFF VALVE (AUTOMATIC) DOMESTIC SYSTEM WATER SUPPLY CONTROL MAIN / GATE WATER VALVE VALVE METER CONTROL VALVE SUPPLY PRESSURE GAUGE /WATER SUPPLY BACKFLOW PREVENTER AS REQUIRED BY AUTHORITY HAVING JURISDICTION WATER SUPPLY MAIN FIGURE 1 TYPICAL INSTALLATION ARRANGEMENT BY-PASS TO FIRE EQUIVALENT SPRINKLER TO MAXIMUM SYSTEM 1/4 INCH OUTSIDE DIAMETER BACKFLOW TUBNG PREVENTER TO DOMESTIC SYSTEM RSV-1 FIGURE 2 REQUIRED BY-PASS FOR BACKFLOW PREVENTION IN FIRE SPRINKLER LINE Design Criteria The TYCO Model RSV-1 Residential Shut-Off Valve must be installed verti- cally with the Water Supply Port at the bottom, the Fire Sprinkler Port at the top, and the Domestic Port at the side (Figures 7 and 8). Figure 1 shows the typical installation arrangement. Refer to the Installation section for addition- al design considerations. Local regulations concerning pub- lic water supplies may require a backflow prevention device. The de- sign of the Model RSV-1 Residential Shut-Off Valve anticipates that the backflow prevention device will be located in the water supply upstream of the Model RSV-1 Valve as shown in Figure 1. Should local regulations require the backflow prevention de- vice to be located in the fire sprinkler line downstream of the Model RSV-1 Valve, a by-pass per Figure 2 must be installed. L'L.)IL.I Do not install a check valve between the Model RSV-1 Residential Shut-Off Valve and the fire sprinklers unless a by-pass per Figure 2 is installed. Installing a by- pass disables performance of the Model RSV-1 Valve as a check valve. Water Supply Requirements 1-Inch (DN25) Valve In order for the 1-Inch (DN25) Model RSV-1 Valve to operate automati- cally upon sprinkler operation, the fire sprinkler system from the water main to the most hydraulically re- mote sprinkler must be designed to provide a minimum single sprinkler flow of 12.5 GPM (47,3 LPM) when the supply pressure at the main is at its minimum expected value. The minimum single sprinkler flow rate of 12.5 GPM (47,3 LPM), re- quired for use with the 1-Inch (DN25) Model RSV-1 Valve, does not take precedence over any more hydrau- lically demanding single sprinkler flow rate specified for the residential sprinklers in use. When performing hydraulic design calculations for the fire sprinkler system, you need not account for the trickle flow through the 1-Inch (DN25) Model RSV-1 Valve By- Pass Restriction into the domestic system. For the 1-Inch (DN25) Model RSV-1 Valve, the maximum water supply service line is 1 inch (DN25). 3-5/8 DIA. FIRE Components: (92,1 mm) SPRINKLER PORT, 1" NPT 1-Body 2- Top Cover 2 3 - Screw, 5 Upper Cap 4 - Upper Cap ' DOMESTIC PORT 3-1/4 5 - 0-Ring, , (82,6 mm) Cover (2) 4 1" NPT 6 - Upper Seal 7 - 0-Ring, 6 Upper Sleeve 15 I 8-3/16" 8 - Sleeve (208,0 mm) 9 -Spring 8 10 10 - Differential 4-15/16 Ring 9 (125,4 mm) 11 - Lower Seal 12 - Screw, z I Piston (4) 12 5 13 - Bottom Cover 14 - Piston 13 1 15 - 0-Ring, WATER Lower Sleeve SUPPLY 2-3/8 PORT, 1 NPT I (60,3 mm) FIGURE 3 1-INCH (DN25) MODEL RSV-1 RESIDENTIAL SHUT-OFF VALVE ASSEMBLY AND DIMENSIONS TFP98O Page 3 of 8 Operating Principles When a fire sprinkler activates dur- ing domestic usage, the TYCO Model RSV-1 Residential Shut-Off Valve automatically shuts off flow to the domestic system and diverts the avail- able water supply to the fire sprinkler system, thereby eliminating a reduced flow condition in the sprinkler system that might otherwise be caused by possible significant domestic water usage. When the Model RSV-1 Valve is in the normal standby position as shown in Figures 7 and 8, the Piston Assembly, assisted by its Spring, is in the down position. With the Piston Assembly in the down position, the Fire Sprinkler Seal permits the Model RSV-1 Valve to perform as a conventional check valve. Also, with the Piston Assembly in the down position, water is avail- able on demand through the Domestic Flow Passage and out the Domestic Port. Upon operation and with a mini- mum design water flow—that is, 12.5 GPM (47,3 LPM) for the 1-inch Valve or 8 GPM (30,5 LPM) for the 2-Inch Valve—to the automatic residential fire sprinkler system, the Piston Assembly moves upward. With the Piston As- sembly in the up position, any water flow to the Domestic Port is diverted to the Fire Sprinkler Port. The contours of the Piston Assembly are specifically configured to minimize its upward movement except under the level of sustained fire sprinkler system flow resulting from operation of one or more fire sprinklers. How- ever, because most fire sprinkler sys- tems contain air pockets, the Piston Assembly tends to move momentarily upward when there is a surge in sup- ply pressure. The momentary opening and re-clos- ing of the Piston Assembly at the Fire Sprinkler Line Seal traps a portion of the pressure increase within the fire sprinkler system. Trapped pres- sure increases within the fire sprinkler system help to prevent a subsequent surge in the supply pressure from causing the water-flow detector to sig- nal a false alarm (unless a by-pass is installed per Figure 2). Components: 1 - Body 2 - Insert Sleeve Bottom Seal Piston Cover Piston Seal 6 - Piston Insert 7 - Piston Spring 8 - Piston Nut 9 - Insert Sleeve 0-Ring (2) 10 - Cover 0-Ring 11 - Retainer Ring Cover Bottom Seal 0-Ring -5-3/8" DIA. FIRE (136,5 mm) SPRINKLER 12 PORT, 2' NPT 10 11DOMESTIC 2" NPT 11 1 4-9/161 15,9 m 124 ~ Bill 13 WATER 8 SUPPLY 3-3/4" PORT. 2 NPT 95,3 mm) FIGURE 4 2-INCH (DN50) MODEL RSV-1 RESIDENTIAL SHUT-OFF VALVE ASSEMBLY AND DIMENSIONS TFP98O Page 4 of 8 As indicated above, domestic system usage can reduce the pressure avail- able to the fire sprinkler system. How- ever, when utilizing the Model RSV-1 Valve, you do not need to include ad- ditional hydraulic flow of the domestic system, when otherwise required by NFPA standards (NFPA 13R), to deter- mine the minimum possible residual (flowing) pressure available to the fire sprinkler system. For operation of the Model RSV-1 Res- idential Shut-Off Valve, you need only design the fire sprinkler system from the water supply main to the most hy- draulically remote sprinkler. Domestic flow does not require consideration. As long as the single sprinkler flow is equal to or greater than 12.5 GPM (47,3 LPM) for the 1-Inch Valve or 8 GPM (30,5 LPM) for the 2-Inch Valve when the supply pressure at the main is at its minimum expected value, the Model RSV-1 Valve automatically shuts off the domestic flow. After the Piston Assembly has moved to the full up position, only a small amount of water is permitted to trickle through the Internal By-Pass Restric- tion to the Domestic Port (Figures 7 and 8). The trickle flow through the Internal By-Pass Restriction permits the Model RSV-1 Valve to reset auto- matically after a sprinkler operation or test without draining the fire sprinkler system. When the Domestic Control Valve is closed, the Internal By-Pass Restric- tion allows the Supply and Domestic Port pressures to equalize and the Piston Assembly to move back down to the standby position. The maximum flow rate through the Internal By-Pass Restriction, when the Model RSV-1 Valve is in the op- erated position, is less than 1/4 GPM (0,9 LPM) for a typical residual (flow- ing) pressure of 40 psi (2,8 bar) at the inlet. Consequently, when performing hydraulic design calculations for the fire sprinkler system, you do not need to consider trickle flow through the Model RSV-1 Valve Internal By-Pass Restriction into the domestic system. Yjl I IIi(fg) ;s '•I IdUflIUflfflflHIflhIhflfl ...i.il II NM w uIlIIU•••U•UU•RUUI••••UU'AuIIVI Ihhhhhh ''h"4" 11111009uuu.uamuuuiriueu•uiuuiipni4s IIuII•l•Hua••IuIuuI••..rAuuuuI'InI uiiiiuuuuiuuiu•uiuiiiiu•euiwii iiiii.....i.i......i.u....va.u.u,iuii ii IIIIiiIlIIIIIUlIIIIIIIIlIIIlVflhl :::::: ii • • :r.r,:::: 1111 11 11111MOMMENIMMUMEN IIIIlU•UUUIBU••U uuuii.l..lII.B... MIS, On IN * 4•••WIIUIulIII MWERFE00654111 a•••r41u•uiiinl S Is 00 me • 1111101010101 INS10100 ________________ • HHNSUUIT U11 .N..ulu..u.i.uuuuuii mono UhI••••41•I•V••••BIIeU•UUUIIuuuII S S S ______________ ,IIII.u.r..u..'a...u•uuu•••Iuuauuuui.i uiliI•ULliUiiVS••iUUuiU•UIUiluuuIiiI 101111 4UiiiViUIIIIiuiIlIUIiiuuuuiIII uIuuIV4•fl•AIS•••S•U•••flUuuuuIU uI.hI'...u.,.I...u.uau.......IIU.IIII IllI'N•e••'4uI••S•••lII•uau••uuIIuui w'I.•.Iruuu.••u...alu...11uluiiuui rSuI..w4uuuI..•u.u.uiu......iuuu.'uu taiiiuyaiiiim••uu.iii.•..s.i.urni,.i .IIIIIUr4IUlIuIUUIUIuIIII•lIUIIluIIIIIII 14 vyIIu.l!f) S kML} IS S III - IuIuI•.UUam u•a•a•••••y R.U•elPiSJjS 11111uuiui1u010•v11 i... iuuiuuiiiia•••.ri...• iiii•uu••uuu•uuu•uruuu•u s is ' ::::::::::::i::::F. • S •....___________,.__...__ ___________ ...•.___.__..________..__ • mmoommmmm ______________ I . all, MMMO On WOO= Usso 00 mmmmosomm II II r in u.In...••lu.p1....... flifl..U..11i...fllllr4 IIIIUUU••U•IKW4U•l ME • • ________IIIII•U••u•WWuu•IpM S uuuiu•uuuuuumau fflhIUUUuUA.UL4Il.0 I - _I ; lIIUUIIIiUUIflhlU • • iiiuuuuuriuurunuu_______ _________ • luISiU••UU FARM DAflS•U Mono _iiuiiu••iwiau•u•u•u• IIIII•••Ur4I u••u•Ia II•UWiIIlPUUlI•Uuul•Vo IIlUUW4IHPdU••uBuuulu•I IIlHUVuIElI...luuuuuI..asAs: IIIIl•!ilPrd•uIu•uu•Il••a•lv _S T.SI55Ira•U..i.sullu IuSSpaE•u••••••a•l•u •. U.UIIIIAUl•U•u••lIU ruir1irA•••uIuua•••lui •_III •_ I•UUUUUUI•••IUUIU S SI. II!M is ,dlIIUU•uuuuI•••UUuI1• DOMESTIC FLOW PASSAGE PISTON ASSEMBLY IE KLER AT JMESTIC PORT TO )OMESTIC STIC FIRE SPRINKLER PORT TFP98O Page 5 of 8 TO FIRE FIRE PISTON SPRINKLERS SPRINKLER ASSEMBLY PORT FIRE FIRE SPRINKLER SPRINKLER SEAT FLOW - PASSAGE DOMESTIC INTERNAL PORT BY-PASS RESTRICTION SUPPLY PORT DOMESTIC SUPPLY SEAT PORT SUPPLY SUPPLY STANDBY OPERATED FIGURE 7 STANDBY AND OPERATED POSITIONS FOR 1-INCH (DN25) MODEL RSV-1 VALVE TO FIRE SPRINKLERS FIRE A FIRE SPRINKLER PISTON PISTON *______ SPRINKLER PORT ASSEMBLY ASSEMBLY I _- PORT FIRE FIRE SPRINKLER FIRE SPRINKLER SE T SPRINKLER FLOW SEAT PASSAGE DOMESTIC PORT TO DOMESTIC DOMESTIC FLOW SEAT PORT PASSAGE D OMESTIC INTERNAL DOMESTIC BY-PASS SUPPLY _______f RESTRICTION SUPPLY PORT PORT SUPPLY DOMESTIC" SUPPLY SEAT STANDBY OPERATED FIGURE 8 STANDBY AND OPERATED POSITIONS FOR 2-INCH (DN50) MODEL RSV-1 VALVE TFP98O Page 6 of 8 Installation A fire sprinkler water supply connection to a public water supply is usually subject to local regulations concerning metering and back flow prevention requirements. Consult with the local water authorities cicerning local requirements that may apply to the arrangement of these components in the fire sprinkler system water supply. Figure 1 illustrates a typical instal- lation arrangement using the TYCO Model RSV-1 Residential Shut-Off Valve. The arrangement may need to be modified to meet the requirements of the authority having jurisdiction. However, the Model RSV-1 Valve must be installed in accordance with the following criteria. Note: For the 1-Inch (DN25) Valve, the maximum water supply service line is 1-Inch (DN25). Ensure that the water supply to the Model RSV-1 Valve is free of contami- nants and particles of a size greater than 1/8 inch (3,2 mm). Install the Model RSV-1 Valve verti- cally with the Supply Port at the bot- tom, the Fire Sprinkler Port at the top, and the Domestic Port at the side. Ensure that the arrows cast on the Body point in the direction of flow. A suitable clamp along the water supply riser piping is recommended to provide support for the weight of the Model RSV-1 Valve. Place a Domestic Control Valve be- tween the Model RSV-1 Valve and the domestic system. Position the inlet to the Domestic Control Valve within 12 inches of the Domestic Port of the Model RSV-1 Valve. The Drain and Flow Test Connection (Figure 1) is recommended to be a minimum 1/2 inch (DN15) size for systems per NFPA 13D, and it must be a minimum 1 inch (DN25) size for systems per NFPA 13R. Install an Alarm Test Connection with a test orifice equal to or less than the smallest K-factor sprinkler in the system downstream of the Waterflow Detector. Apply pipe-thread sealant sparingly only to the male pipe threads that are to be assembled to the three ports of the Model RSV-1 Valve. The use of a non-hardening pipe-thread sealant such as Teflon* is recommended. Valve Setting Procedure Perform steps 1 through 9 when initial- ly filling the fire sprinkler and domestic system piping with water or after a fire sprinkler operation (Figure 1). Close the Main Control Valve. Close the Domestic Control Valve and all water outlets in the domestic piping system. In addition to the Drain and Flow Test Connection in the fire sprinkler system, close all drain valves and replace all operated sprinklers as necessary. Partially open the Main Control Valve until the sound of flowing water just begins, then leave the Main Control Valve in the partially open position. After the fire sprinkler system pres- sure gauge indicates approximately the same pressure as the supply pressure gauge, fully open the Main Control Valve. Open the highest elevation outlet on the domestic system. Partially open the Domestic Control Valve until the sound of flowing water begins. Allow the domestic piping to fill slowly with water. Close the highest elevation water outlet on the domestic system when unaerated water begins to flow. Completely open the Domestic Control Valve, then check that the domestic system is properly pressurized by verifying that at least three water outlets in the domestic system can flow full at the same time. If the water outlets flow fully, the Model RSV-1 Valve is set and ready for service. Close the water outlets on the domestic system. If the water outlets do not flow fully, re-close the Domestic Con- trol Valve, wait a minimum of ten seconds, and ensure that there is no flow from the fire sprinkler sys- tem piping. Reopen the Domestic Control Valve, then recheck that the water outlets are flowing fully. Care and Maintenance The following inspection procedure for the TYCO Model RSV-1 Residential Shut-Off Valve must be performed as indicated, in addition to any specific requirements of the NFPA. Any impair- ment must be immediately corrected. Make no attempt to repair any Model RSV-1 Valve component in the field. The Model RSV-1 Valve is not field-repairable. If malfunction occurs, the entire unit must be replaced. The operational test and flow test procedures result in operation of the associated alarms, as well as an interruption of the domestic water supply service. You must notify the owner, building occupants, and the fire department, central station, or other signal station to which the alarms are connected. Before closing a fire protection system control valve for inspection or maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. After placing a fire protection system in service, notify the proper authorities and advise those responsible for monitoring proprietary and/or central station alarms. Responsibility lies with the owner for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any authority having jurisdiction. Contact the installing contractor or product manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes and standards. *DuPont Registered Trademark TFP9BO Page 7 of 8 Operation Test Procedure Fully open two or three water outlets in the domestic piping system. To simulate a sprinkler operation, open the Alarm Test Connection of the fire sprinkler system. Verify that any alarms are operating and that the flow from the domestic water outlets decreases to no more than a trickle. Reset the Model RSV-1 Valve in ac- cordance with the Valve Setting Pro- cedure described in this data sheet. Flow Test Procedure While there is no water flowing in the domestic system, completely open the Drain and Flow Test Connection. While water is flowing, record the pressure reading on the fire sprin- kler system pressure gauge and then compare this reading to previ- ous readings. If there is a significant decrease in pressure since the last time the pressure reading was taken and this decrease is not due to a normally expected drop in the water supply pressure, an impairment may exist that should be immediately identified and corrected. Close the Drain and Flow Test Con- nection to allow the Model RSV-1 Valve to reset automatically. Automatic resetting occurs within ten seconds. After waiting ten seconds, completely open at least three water outlets in the domestic system and allow these outlets to flow simultaneously. If the water outlets flow fully, the Model RSV-1 Valve is set and ready for service. Close the water outlets on the domestic system. If the water outlets do not flow fully, close the Domestic Control Valve and verify that there is no flow from the fire sprinkler system piping, such as at the Inspector's Test Connec- tion. Wait a minimum often seconds. Re-open the Domestic Control Valve and then recheck that the domestic system water outlets are flowing full. Limited Warranty Products manufactured by Tyco Fire Suppression & Building Prod- ucts (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under nor- mal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for products or components manufactured by companies not affili- ated by ownership with TFSBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFSBP to be defective shall be ei- ther repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connec- tion with the sale of products or parts of products. TFSBP shall not be re- sponsible for sprinkler system design errors or inaccurate or incomplete in- formation supplied by Buyer or Buy- er's representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for inciden- tal, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFSBP was informed about the pos- sibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or imrJlied. including warran- ties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Information Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name and Part Number (P/N). Valves with NPT Connections Specify 1-Inch NPT (DN25) Model RSV-1 Residential Shut-Off Valve, P/N 52-540-1-001. Specify 2-Inch NPT (DN50) Model RSV-1 Residential Shut-Off Valve, P/N 52-540-1-002. Valves with ISO Connections Specify ISO Rd (DN25) Model RSV-1 Residential Shut-Off Valve, P/N 52-540-1-011. Specify ISO Rc2 (DN50) Model RSV-1 Residential Shut-Off Valve, P/N 52-540-1-204. TFP98O Page 8 of 8 Copyright © 2010 Tyco Fire Suppression & Building Products. All rights reserved.