Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1925 CALLE BARCELONA; ; AS050217
Applicant: Owner: A& D FIRE PROTECTION 10759 WOODSIDE AVE SANTEE, CA 92071 619-448-1962 BORDERS INC FOURTH QUARTER PROPERTIES XXX L C/O DELOITTE TAX LLP P0 BOX 131071 CARLSBAD CA 8/9/24, 11:29 AM AS050217 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS050217 1925 CALLE Job Address: Status: APPROVED BARCELONA Permit Type: SPRINK Applied 10/13/2005 Parcel No: 2550120400 Approved: 10/18/2005 Lot #: 0 Reference No.: Issued: 10/18/2005 PC #: Inspector: Project Title: CHICO'S SUITE 160/161 FIRE SPRINKLER PLAN CHECK & INSPECTIONS Fees ($) Add'I Fees ($) F Total ($) Balance L 120 0 120 0 about:blank 1/1 Asosb2iqo A & D Fire Protection, Inc. A Division of A & 0 Companies Contract Sales -Service Department 11465 Woodside Avenue, 2"' Floor Santee, California 92071 Tel: 619.448. 1962 ext. 20 Fax: 619.448.1265 Email: andcorpl@aol.com FIRE PROTECTION INC. This correspondence may contain confidential information intended for the use of the individual or entity to whom it is addressed. If the reader is not the intended recipient, or the employee or agent responsible to deliver it to the intended recipient, you are hereby notified that any dissemination or copying is strictly prohibited. Date: 10/11/2005 To: Carlsbad Fire Department From: Mark Keller S u b j e c t: CHICO'S EXPANTION MATERIAL SUBMITTAL FOR CHICO'S EXPANTION Bldg. #5 Space #160-161 THE FORUM @ CARLSBAD 1925 Calle Barcelona CARLSBAD, CA 92009 ** Materials of equal design, utility, and performance may be substituted for submitted materials so as to avoid delays in the construction schedule and shall be deemed accepted by the Purchaser. JtauIic® AUTOMATIC SPRINKLERS FIRE PROTECTION PRODUCTS V38, K5.6 Models V3801 andTV8 Adjustable Concealed Standard Spray Pendent Standard and Quick Response PRODUCT See Victaulic publication 10.01 or details, DESCRIPTION This concealed, designer style sprinkler allows up to 1/2' (13 mm) adjustment to accommodate conceal- ment needs. The stan- dard" design provides a consistent hemispherical spray pattern. The sepa- V3801 rate two-piece mounting V3802 cup/cover plate allows easy installation and testing prior to ceiling installation. It also permits removal of suspended ceiling panels without system shutdown. The design incorporates state-of-the-art, heat responsive, frangible glass bulb design (standard or quick response) for prompt, precise operation. This sprinkler is available in various temperature ratings (see chart on page 2) and finishes to meet many design requirements. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to dis- tribute the water in a pat- tern that is most effective in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. TECHNICAL SPECIFICATIONS Models: V3801, V3802 Style: Adjustable concealed, ordinary hazard Nominal Orifice Size: ½" (13 mm) K-Factor: 5.6 Imp. (8,1 S.I.A) Nominal Thread Size: ½" NPT (15 mm) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test: 100% @ 500 psi (3450 kPa) Mm. Operating Pressure: 7 psi (48 kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Deflector: Bronze per UNS C22000 Cover Plate: Fusible solder Bulb: Glass with glycerin solu- tion. Bulb Nominal Diameter: D Standard: 5,0 mm Quick Response: 3,0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Stainless steel per UNS S30100 Seal: Teflon* tape Frame: Die cast brass 65-30 Pins: Stainless steel per UNS S30400 Cup: Cold rolled steel, zinc chrome plated Cover/Escutcheon: Brass per UNS C26000 Lodgement Spring: Stainless steel per UNS S30200 Protective Cap: Polyethylene ACCESSORIES Installation Wrench: Concealed: V38-4 or V38-5 Sprinkler Finishes: 3 Plain brass (only) Cover Finishes: 0 Chrome plated 0 White painted 0 Flat black 0 Custom painted ° For K-Factor when pressure is mea- sured in Bar, multiply SA. units by 10.0. 'Teflon is a registered trademark of Du- pont Co. VICTAULIC5 IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800-PICK-VIC (1-800-142-5842) Phone: 905-884-7444 Phone: 32-9-381-1500 Phone: 610-559-3300 Phone: 65-6235-3035 Fax: 610-250-8811 Fax: 905-884-9774 Fan: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-6235-0535 e-mall:plckvic©nittaulic.com e-mail: viccanada©victaolic.com e-mail: viceuro©viclaulic.be e-mail: vical@victaulic.com e-mail: vicap@victaulic.com 2558 ffev.E 5104 0 Registered Trademark of Victaulic 0 Copyright 2004 Victaulic Printed in U.S.A. APPROVALS/LISTINGS Nominal Approvals f K-Factor I Orifice Size Imperial Deflector Model Inches/mm S.I.° Response Type UL FM ULC NYCflw1EAt CSFM § V3801 1/2 13 5.6 8,1 Standard 5 m bulb Concealed Pendent 155-200 68-93 No 135-200 135-200 57-93 135-200 I 5'-3 V3802 ½ 13 5.6 81 Quick 3 m bulb Concealed Pendent 135-200 I 155-200@ 68-93 135-200 57-93 135-200 1135-200 57-93 I 57-93 Listings and approval as of printing, ' For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. C Recognized by FM as standard response only. t MEA #62-99-E § CSFM #7690-0531:112 RATINGS All glass bulbs are rated for temperatures from -67°F (-55°C) up to those shown in table below. SPRINKLER - V3801, V3802 COVER -V38 Sprinkler Temperature - °F/c Cover Temperature - °FIc Nominal Maximum Nominal Maximum Sprinkler Victaulic Glass Victaulic Temperature Part Temperature Ambient Temp. Bulb Part Temperature Ambient Temp. Classification Identification Rating Allowed Color Identification Rating Allowed Ordinary A 5 1 57 10 38 Orange A* 57 135 100 38 Ordinary C . 15 1 0 Red 68 38 Intermediate E 175 15079 65 Yellow 0 165 74 150 65 Intermediate F 200 93 150 65 Green A For use with Standard or Quick Response Concealed Sprinkler 135F (57*C) or 155*F(68*C). tD For use with Standard or Quick Response Concealed Sprinkler 175*F 179*01 or 200*F (93*C), Custom Finish - Customer to provide paint specification, allow 4 - 6 weeks for samples. Cesium Covers require $150.00 minimum per custom cover; minimum 200 pieces. Proper temperature rated cover must be used with the correct sprinkler rating per the Temperature Chart Ratings. The plastic shipping cap must be removed for the sprinkler to operate properly. It shipping cap is replaced over an installed sprinkler for purposes of painting or plastering, then the lire protection system shall be considered out of service, the Authority Having Jurisdiction notified, and a tirewatch is suggested. Failure to do so may result in failure at sprinkler to operate causing serious personal injury or property damage. ORDERING INFORMATION Please specify the following when ordering: ZI Sprinkler Model Number LI K-Factor LI Cover Finish U Style U Thread Size U Wrench Model Number U Temperature Rating U Quantity . Always read and understand installation, care, and maintenance Instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. , F Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating at sprinklers (other than that supplied by Victaulic) is not allowed. ailure to follow these Instructions could result in serious personal injury and/or property damage. The owner Is responsible for maintaining the tire protection system and devices In proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. in addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that mast he followed. It you need additional copies at this publication, or If you have any questions about the sate Installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610-559-3300. 40,50 -2 DIMENSIONS 211/16 (68 mm) Max. Hole s)60mm) Min. Hole 11/2" (38 mm) Typical Ceiling Tile MINIMUM EXTENSION sā Finished Surface 3/1 (80 mm) 213/16' (71 mm) 2" (51 mm) W (13 mm) Adjustment Typical Ceiling Tile 31/4 (83mm) - Cover Plate "ā Finished Surface ______ MAXIMUM EXTENSION Models V3801, V3802 (Drawings not to scale) AVAILABLE WRENCHES Recessed Concealed Pendent - V3801, V3802 I V38-4 or V38-5 40.50 -3 DISTRIBUTION PATTERNS MODELS V3801, V3802 K5.6 STANDARD CONCEALED PENDENT 10' 3,0 iii 7psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa 2' 4 6 8 10 12 14' 0,6m 1,2m iBm 2,4m 3,0m 3,7w 4,3m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right 10 change product specifications, designs and standard equipment without notice and without incurring obligations. 40.50 -4