HomeMy WebLinkAbout2215 CALLE BARCELONA; ; FA0600398/9/24, 11:33 AM FA060039 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA060039 2215 CALLE Job Address: Status: ISSUED BARCELONA Permit Type: FALARM Applied 6/26/2006 Parcel No: 2552730700 Approved: 6/26/2006 Lot #: 0 Reference No.: Issued: 6/26/2006 PC #: Inspector: Project Title: COASTLINE COMMUNITY CHURCH TWO (2) FIRE ALARM FIRE INSPECTIONS @ $60/EA Applicant: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO CA 760-747-3050 Owner: COASTLINE COMMUNITY CHURCH 511 ENCINITAS BLVD #104 ENCINITAS CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 120 0 J 120 J 0 J about:blank 1/1 mmmm 12212M !!SES FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS COASTLINE COMMUNITY CHURCH 2215 CALLE BARCELONA CARLSBAD, CALIFORNIA 92008 FIRE ALARM SYSTEM APPROVED A 'jd SIITTED CARLSBAD FW 1FMENT COASTLINE COMMUNITY CHURCH 2215 CALLE BARCELONA, CARLSBAD, CALIFORNIA BILL OF MATERIALS NOTIFIER NFW-100 FIRE ALARM PANEL CSFM# 7165-0028:235 NOTIFIER FCPS-24S6 POWER SUPPLY CSFM# 7315-0028:225 NOTIFIER FDU-80 ANNUNCIATOR CSFM# 7120-0028:209 NOTIFIER NP-100 PHOTO SMOKE DETECTOR CSFM# 7272-0028:231 NOTIFIER ND-100 DUCT DETECTOR WIWEATHERPROOF ENCLOSURE CSFM# 3240-0028:236 NOTIFIER NOT-BGI2LX ADDRESSABLE PULL STATION CSFM# 7150-0028:199 NOTIFIER NMM-100P ADDRESSABLE MONITOR MODULE CSFM# 7300-0028:230 NOTIFIER NC-100 ADDRESSABLE RELAY MODULE CSFM# 7300-0028:230 WHEELOCK AS SERIES HORN/STROBES CSFM# 7125-0785:131 WHEELOCK RSS SERIES STROBES CSFM# 7125-0785:141 SYSTEM SENSOR RTS45I CSFM# 7300-1653:110 WEST PENN WIRE CO. FPL TYPE AQUASEAL CSFM# 7161-0859:101 TAPPAN WIRE AND CABLE FPLR TYPE CSFM# 7161-1384:101 WERKER SEALED LEAD ACID BATTERIES August 11, 2005 DN-7005 •A1-100 NOTIFIER by Honeywell GENERAL The NOTIFIER FireWarden-100 (NFW-100) is a compact, cost-effective, intelligent addressable fire alarm control panel with a capacity of 198 addressable NOTIFIER de- vices on one Signaling Line Circuit (SLC) and a built-in modem for remote site upload/download or remote moni- toring. The Signaling Line Circuit (SLC) loop supports up to 99 addressable detectors including photoelectric, photoelec- tric with heat, ionization, photoelectric duct, fixed heat, and fixed heat with rate-of-rise detectors. It also supports up to 99 addressable modules including monitor (two-wire detector, normally open devices), conventional two-wire smoke monitor (supervise compatible two-wire smoke de- tectors), and relay (two Form-C) modules. The panel uses surface-mount technology and is designed for ease of in- stallation, programming, and maintenance. It features the latest in advanced fire protection technology, including maintenance alert and automatic detector test functions. SPECIAL FEATURES: Built-in modem. Selectable strobe synchronization per NAC. Remote site upload/download. Four Class B or two Class A NAG circuits. FEATURES SLC Loop: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices (99 de- tectors and 99 monitor, control, or relay modules), in- cluding addressable smoke detectors, heat detectors, and duct detector. SLC loop maximum length 10,000 ft. (3,048 m) @ 12 AWG (3.1 mm2). Requires twisted, shielded wire (3,000 ff1914.4 m untwisted, unshielded wire). Notification Appliance Circuits (NACs): Four onboard NACs with additional NAC capability us- ing output control modules (NC-100). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 5.0 amps total NAC power with XRM-24. Advanced Fire Technology: Sensitivity testing with printable results, onsite or offsite. Automatic drift compensation. Programming and Software: Autoprogram (learn mode) reduces installation time. Fully programmable from local keypad, local P5-2 key- board or PC via VFWARDEN-CD Windows® utility. FireWarden-1 00 Intelligent Addressable FACP (NFW-1 00) with Built-In Modem Section: Addressable IVI EA California & 3't 0 1 III Marshal 7165-0028:235 LISTED S635 <*> APPROVED Remote site upload/download capability. Two-level user-programmable passwords. Custom English labels (per point) may be manually en- tered or selected from an internal library file. Two programmable Form-C relay outputs. 99 software zones. User Interface: Built-in modem (DACT). Remote Acknowledge, Silence, Reset and Drill via ad- dressable monitor modules, ACS Series annunciators or FDU-80 remote annunciator. EIA-232 printer/PC interface (variable rate) on main cir- cuit board. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight sav- ings adjustments. History file with 1,000-event capacity. EIA-485 supporting up to 32 ACS Series annunciators. ElA-485 supporting up to 32 FDU-80 annunciators. Maintenance alert warns when smoke detector dust ac- cumulation is excessive. Automatic device type-code verification. cont'd pg. 3 This document is not intended to be used for installation purposes. We try to keep our I product information up-to-dale and accurate We cannot cover all specific applications or I ISO 9001 anticipate all requirements. All specifications are subject to change without notice. I For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 I a I =1 I 1 j I NOT* Ft E R ENGINEERING & MANUFflCIIIIINC Made,n the U.S A. by Honeywell 12 Clintonville Road, Nohtord, Connecticut 06472 QUALITY S Y STEMS DN-7005 • 08/11/05 - Page 1 of 4 Fire Warden-100 Fire Alarm Control! Communicator Optional REVERSE POLARITY! CITY BOX OUTPUT (4XTM) 8 FORM-C, 5-AMP RELAYS (optional, order ACM-8R) NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES SMOKE DETECTORS NP-100, NIP-100T, NI-100 LN I HEAT DETECTORS NH-100, NH-100R 101 DUCT DETECTOR ND-100, ND-100R EIA -485 INTERFACE 24 VOC (DIM-485) built into the motherboard (four wires) 0 C CD CD FDU-80 Up to 6.000 ft. (1825.8 m) between each FOU-80 in the EIA-485 loop, and between each FOU-80 - and the FACP 24 VOC .1 I EIA .485 ACS 4 mo 1Eredein 1 0 ANNUNCIATORS AFM-LEO, LDM, EIA-232 ACS/ACM INTERFACE (PIM-24) built into the motherboard NOTE: System can use either the printer OR the FDU-80. They cannot be used simultaneously. MONITOR I CONTROL NMM-100, NZM-100, NDM-100, N100-ISO, NC-100, NC-100R 0' " MINI MONITOR NJMM-100P WIRING REQUIREMENTS The SLC requires use of a specific wire type to ensure proper circuit operation. It is recommended that all SLC wiring be twisted-pair shielded to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Use the table below to determine the specific wiring requirements for the SLC. Wire Distance Typical Wire Size Requirements in Feet (m) Twisted-pair, shielded 10,000 feet 12 AWG (3.1 mm 2): Belden 9583, Genesis 4410, 14 AWG (2.00 mm2): Belden 9581, Genesis 4408, (3,048 m) Signal 98230, WPW 0999. 16 AWG (1.3 mm2): Belden 9575, Genesis 4406 Twisted-pair, shielded 8,000 feet (2,438 m) Signal 98430, WPW 0995. 18 AWG (0.78 mm2): Belden 9574, Genesis 4402 Twisted-pair, shielded 4,875 feet (1,486 m) and 4606, Signal 98630, WPW D991. Twisted-pair, shielded 3,225 feet (983 m) and 4602, Signal 98300, WPW 0975. Unwisted, unshielded 3,000 feet (915 m) 12— 18 AWG (3.1 —0.78 mm2). '7J'48111111 Page 2014 - DN-7005 • 08/11/05 PULL STATION NOT-BG1 2LX 70050.wrn1 One person audible or silent walk test with walk-test log and printout. Point trouble identification. Local piezo sounder. Waterflow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). Optional 4XTM module (conventional reverse polarity/city box transmitter). CONTROLS AND INDICATORS LED INDICATORS AC POWER (green) FIRE ALARM (red) SUPERVISORY (yellow) ALARM SILENCED (yellow) SYSTEM TROUBLE (yellow) MAINTENANCE (yellow) DISABLED (yellow) BATTERY FAULT (yellow) GROUND FAULT (yellow) MEMBRANE SWITCH CONTROLS ACKNOWLEDGE/STEP ALARM SILENCE DRILL SYSTEM RESET (lamp test) 5 -16. 12-key pad with full alphabet 17 -20. 4 cursor keys 21. ENTER FIELD-PROGRAMMING FEATURES OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (or- der programming kit VFWARDEN-CD separately). Up- load/download system programming locally to the FireWarden-100 in less than one minute. AUTOPROGRAMMING: Command the FireWarden-100 to program itself (takes less than 30 seconds). In the Auto- Program mode, the FireWarden-100 scans for all possible devices at all addresses, stores the device types, and ad- dresses found, and then loads default values for all op- tions (General Alarm). It also checks for two or more de- vices set to the same address. ONLINE EDIT: While still providing fire protection, the FireWarden-100 may be programmed from the front panel. Simple menu trees displayed on the LCD allow the trained user to perform all functions without referring back to the programming manual. ENGLISH LABEL LIBRARY: Quickly select labels from a standard library of more than 50 adjectives/nouns, such as "FLR 3 HALLWAY," or enter custom labels letter-by-letter. Use recall function to repeat previously used label. PROGRAM CHECK: Automatically catch common errors, such as control modules not linked to any zone or input point. MAINTENANCE ALERT The FireWarden-100 continuously monitors each smoke detector and is capable of reporting maintenance condi- tions. This reduces the risk of false alarms due to dust accumulation. Refer to the control panel installation manual for more information. AUTOMATIC TEST OPERATION The FireWarden-100 performs an automatic test of each detector every two hours. Failure to meet the test limits causes a TESTF trouble type. System Reset clears this trouble. NFPA STANDARDS The FireWarden-100 complies with the following NFPA 72 Fire Alarm Systems requirements: LOCAL (Automatic, Manual, Waterflow and Sprinkler Su- pervisory). AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). REMOTE STATION (Automatic, Manual and Waterflow) (requires 4XTM). PROPRIETARY (Automatic, Manual and Waterflow). CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). SPECIFICATIONS AC Power - TB1: 120 VAC, 60 Hz, 3.0 A. Wire size: mini- mum 14 AWG (2.0 mm2) with 600 V insulation. Battery (lead acid only) - TB2: Maximum charging circuit: Normal flat charge 27.6 VDC @ 0.80 A. Maximum battery charger capacity: 18 AH. FireWarden-100 cabinet holds maximum of two 18 AH batteries. For 25- 120 AH batter- ies, use the CHG-120 or CHG-75 Battery Charger and BB- 55 Battery Box. NOTE: Jumper JP3, on the FACP main circuit board, must be cut to disable the FACP battery charger when using the CHG- 120. Remote Synchronization Output - TB2: A 24 VDC, 40 mA signal that mimics the sync signal of NAC 1 and can be utilized by remote power supplies such as the FCPS-2456/ -24S8. This allows NAC devices attached to the power supply to synchronize with the devices connected to NAC 1 of the FACP. Communication Loop - (standard) T138: 24 VDC nomi- nal, 27.6 VDC maximum. Maximum length: 10,000 ft. (3048 m) total twisted, shielded pair length. Maximum loop cur- rent 400 mA (short circuit) or 100 mA (normal). Maximum loop resistance: 40 ohms. Supervised and power-limited. Notification Appliance Circuits - TB4: Power-limited cir- cuitry. Maximum voltage drop in wiring: 2.0 VDC. Nominal operating voltage:24 VDC. Current limit: fuseless, electronic, power-limited circuitry. Maximum signaling current per cir- cuit: 2.50 A. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252, UL Listed) for NACs. Refer to NOTIFIER Device Compatibility Document for listed compatible devices. Programmable and Trouble Output Relays - TB5, TB6, TB7: Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays. Four-Wire Resettable Smoke Detector Power (24 VDC nominal) - TB1, Terminals 3 (+) & 4 (-): Maximum ripple voltage: 10 mVRMS. Up to 0.5 A for powering four-wire smoke detectors. Power-limited circuit. Refer to NOTIFIER Device Compatibility Document for listed compatible de- vices. Nonresettable Power #1(24 VDC Nominal) -TB1, Termi- nals 3 (+) & 4 (-): Maximum ripple voltage: 10 mVRMS. Up to 0.5 A total DC current available from each output. Power- limited circuit. TB1, Terminals 1 (+) & 2 (-) can be config- ured as resettable 24 V or non-resettable via JP4. NOTE: If using optional XRM-24, total NAC and auxiliary cur- rent draw cannot exceed 6.0 amps. EIA-485 (ACS) - TB6: ACS annunciator connector, Termi- nal 1 (+) and Terminal 2 (-). EIA-485 (TERM) - TB7: Terminal mode annunciator con- nector, Terminal 1 (Out +), 2 (In +), 3 (Out -), 4 (In -). EIA-232 - TB8: PC/printer connector, Terminal 1 (Trans- mit), 2 (Receive), 3 (DTR), 4 (Ground). ON.7005•08/11/05 - Page 3oI4 CABINET SPECIFICATIONS Door: 18.67" (47.43 cm) high x 15.78' (40.08 cm) wide x 1.08" (2.74 cm) deep. Backbox: 18.50' (47.0 cm) high x 15.50' (39.37 cm) wide x 4.37" (11.1 cm) deep. Trim Ring (NFW-TR): 21.62' (54.92 cm) high x 18.62" (47.3 cm) wide. PRODUCT LINE INFORMATION NFW-100: 198-point addressable Fire Alarm Control Panel, Includes 80-character LCD display, single printed circuit board, and cabinet. ACM-8R: Optional plug-in relay module provides 8 Form-C 5.0 A relays. VFWARDEN-CD: Contains panel programming software for Windows®-based PC computer (cable not included). DP-FW-100: Dress panel for FireWarden-100. NFW-TR: Trim Ring for semi-flush mounting. BB-55: Battery box, required to house two BAT-12260 batteries and one CHG-120 battery charger. For batteries greater than 26 AH, consult factory for housing/mounting arrangements. B13-6: Battery backbox, holds up to two BAT-i 2260 batteries. CHG-120: Remote battery charging system for lead-acid batteries with a rating of 25 to 120 AH. CHG-120 or CHG- 75 required for charging greater than 25 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120 or CHG-75 required for charging greater than 25 AH batteries. BAT-12180: Battery, 12 volt, 18.0 AH, (two required). BAT-12260: Battery, 12 volt, 26 AH, (two required;, requires CHG-75). BAT-12550: Battery, 12 volt, 55 AH, (two required; requires CHG-75). PRT/PK-CABLE: Cable printer/personal computer interface cable. For use with printer or VFWARDEN-CD. Windows® is a registered trademark of Microsoft Corporation. COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI-100: Addressable low-profile ionization smoke detector. NP-100: Addressable low-profile photoelectric smoke's' detector. NP-lOOT: Addressable low-profile photoelectric smoke detector with thermal sensor. NH-100: Fast-response, low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate-of-rise. ND-100: Photoelectric duct smoke detector. ND-100R: Photoelectric duct smoke detector with relay. NMM-100: Addressable Monitor Module for one zone of normally-open dry-contact initiating devices. Mounts in standard 4.0' (10.16 cm) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 conventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible detectors. NDM-100: Dual Monitor Module. Same as NMM-1 00 except it provides two Style V (Class B) only lDCs. NC-100: Addressable Control Module for one Style VIZ (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm) box, surface mount using the SMB500. NOT-BG12LX: Addressable manual pull station with interface module mounted inside. N100-ISO: Fault Isolator Module. SMB500: Used to mount all modules except the NMM- loop. NOTE: For more information on Compatible Addressable De- vices for use with the Fire Wa rden-100, see the following data sheets (document numbers): N100-ISO (DN-6994), NP-fool NP-lOOT (DN-6995), NI-i 00 (DN-6996), NH-100/NH-I00R (ON- 6997), ND-100/ND-IOOR (DN-7006), NMM-lOOINMM-iOOP/ NDM-100/NZM-100 (DN-6999), NC-100/NC-I0OR (DN-7000), and NOT-BG12LX (DN-700 1). COMPATIBLE ANNUNCIATORS EIA-485 interface: Built into the motherboard. AFM-LED Zone Series: LED-type fire annunciators ca- pable of providing up to 99 software zones of annuncia- tion. Available in increments of 16 or 32 with expandable (AFM-X Series) and non-expandable (AFM Series) con- figurations to meet a variety of applications. ACS/ACM Annunciator Series: Allows annunciation of loop modules and detectors. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. FDIJ-80 (Liquid Crystal Display) point annunciator: 80- character, backlit LCD-type fire annunciators capable of displaying English-language text. Up to 32 FDU-80 an- nunciators may be connected to the EIA-485 terminal mode serial interface on the FireWarden-100 motherboard. NOTE: For more information on Compatible Annunciators for use with the FireWarden- 100, see the following data sheets (document numbers) AFM/AFM-X Series (ON-0056), ACM- 81? (ON-3558), ACS/ACM Series (DN-0524), FDU-80 (ON- 6820), LDM Series (DN-055 I). AGENCY LISTINGS AND APPROVALS See the first page of this data sheet for listing agencies and file numbers. These listings and approvals apply to the basic FireWarden-1 00 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory Page 4014 - DN-7005 • 08/11/05 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0028:235 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Notifier, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Model Fire Warden 100 addressable control unit. Local, auxiliary, remote station, central station and proprietary (protected premise). Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. XLF: 7165-0075:208 12-09-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 5, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager July 20, 2004 DN-6927 E-30 FCPS-24S6 and FCPS-24S8 N OT I F I E R 6-Amp and 8-Amp 24-Volt Remote Power Supplies Section: Power Supplies GENERAL The FCPS-24S6 (6-amp) and FCPS-24S8 (8-amp) are com- pact, cost-effective remote power supplies with battery charger. The FCPS-24S6/-24S8 may be connected to any 12- or 24- volt Fire Alarm Control Panel (FACP) or may be used as a stand-alone supply. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA re- quirements and NAC synchronization) or auxiliary power to support 24-volt system accessories. The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to four notifi- cation appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alter- nately, the four outputs may be configured as all non-resettable, all resettable, or two non-resettable and two resettable. The FCPS-24S6/-2458 also contains a battery charger capable of charging up to 18 AH batteries. FEATURES UL-Listed NAC synchronization using System Sensor, Wheelock, or Gentex "Commander"' appliances. Cascadable for up to ten power supplies (four for Gentex) with strobe timing maintained. Operates as a "sync follower" or as a "sync generator" (de- fault). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumpered per- manently 'ON" (stand-alone mode). Four Class B (Style Y) or four Class A (Style 7, with ZNAC-4 module) NACs. 6-amp (FCPS-2456) or 8-amp (FCPS-2458) full load output, with 3 amps maximum/circuit, in NAC expander mode (UL 864). 4-amp (FCPS-2456) or 6-amp (FCPS-2458) continuous out- put in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (A77-7168). In stand-alone mode, output power circuits may be config- ured as: resettable (reset line from FACP required), non- resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NACs. Selectable earth fault detection. AC trouble report selectable for immediate or 8-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9.0 - 32 VDC. Self-contained in compact, locking cabinet— 15" (38.1 cm) high x 14.5" (36.83 cm) wide x 2.75" (6.985 cm) deep. Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries. California State Fire Marshal 7315-0028:225 LISTED APPROVED S635 MEA 299-02-E Battery charger maybe disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire. STANDARDS and CODES The FCPS-24561-2458 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems (stand- alone mode). SPECIFICATIONS Primary (AC) power: FCPS-2456/-2458: 120 VAC, 60 Hz, 3.2 A maximum. Wire size: minimum #14 AWG (2.0 mm') with 600V insulation. Control input circuit: Trigger input voltage: 9 to 32 VDC. Trigger current: 2.0 mA (16-32 V). Per input: 1.0 mA (9- 16 V). Trouble contact rating: 5 amps at 24 VDC. NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. i For more information, contact NOTIFtER. Phone: 12031 484-7161 FAX: 12031 484-7118 ENGINEERING & MANUFAflhIING N OTI F I E fl' 12 Clintonville Road, Northtord, Connecticut 06472 QU ALIT Y SYSTEMS DN-6927 • 07/20/04 - Page 1 of 3 Auxiliary power output: specific application power 500 mA maximum. Output circuits: +24 VDC filtered, regulated. 3.0 amps maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): for FCPS-24S6: 4.0 amps maximum; for FCPS-24S8: 6.0 amps maximum. Total short-term current for all outputs (NAC expander mode): for FCPS-24S6: 6.0 amps maximum; for FCPS-24S8: 8.0 amps maximum. Secondary power (battery) charging circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. Maximum charge current: 1.5 amps Maximum battery capacity: 18 AH. APPLICATIONS Example 1: Expand notification appliance power an addi- tional 6.0 amps (FCPS-24S6) or 8.0 amps (FCPS-24S8). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polar- ity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24-volt system power up to 4.0 amps (FCPS-24S6) or up to 6.0 amps (FCPS-24S8). Both resettable and non-resettable power options are available. Resettable outputs are created by connecting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances" away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. "Addressable FACPS are capable of locating control and monitor Style Y NAC or modules at distances of up to Door Holder 10,000 feet (3048 meters). Power St i AGENCY LISTINGS Output #4 O AND APPROVALS See the first page of this data sheet for listing agencies and file numbers. These listings and ap- provals apply to the FCPS-24S6 and the FCPS-24S8. In some cases, certain modules or appli- AC U cations may not be listed by cer- Power tam approval agencies, or listing may be in process. Consult fac- tory for latest listing status. SYNC FOLLOWER/GENERATOR NOTE In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAG wire run, the FGPS-2456/-2458 can track (i.e., "follow") the strobe synchronization timing pulses on the existing NAG wire run. This maintains the overall system flash timing of the additional strobes attached to the FCPS. When the FCPS-24S6/-24S8 is configured (via DIP switch set- tings) as a "sync follower," the FGPS's NAG outputs track the strobe synchronization pulses present at the FGPS's sync in- put terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24S6/-24S8 is configured (via DIP switch set- tings) as a "sync generator," the FGPS's sync input terminals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FGPS's NAG outputs. In 'sync generator' mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. PRODUCT LINE INFORMATION FC PS-24S6: 6.0 amp, 120 VAC remote charger power sup- ply. Includes main printed circuit board, transformers, enclo- sure (15" [38.1 cm] high x 14.5" [36.83 cm] wide x 2.75" [6.985 cm] deep), and installation instructions. FCPS-24S8: 8.0 amp, 120 VAC remote charger power sup- ply. Includes main printed circuit board, transformers, enclo- sure (15" [38.1 cm] high x 14.5" [36.83 cm] wide x 2.75" [6.985 cm] deep), and installation instructions. ZNAC-4: Glass A (Style Z) NAG option module. A77-716B: 12/24 VDC end-of-line relay for monitoring four- wire smoke detector power. BAT-11 270: Battery, 12 volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). PS-I270: Battery, 12 volt, 7.0 AH (two required, see PS Series data sheet DN-1109). NOTE: All NAC outputs can be converted to Style Z with ZNAC-4 option module. FCPS Trouble Contact Output 24 VDC Specific Application Power NAC Control 40111111 Input #2 INPUT/OUTPUT (from FACP) FUNCTIONS are programmable by NAG Control SW1 DIP switch settings Input 41 (from FACP) yle Y NAC Ste V NAC Style V NAC itout #3 Outout #2 Outout #1 Sync Input FCPS SIMPLIFIED Battery Charger BLOCK DIAGRAM Page 2 of 3 - DN-6927 07/20/04 T1132: Power-Limited, NAC/Out 1 + Supervised in NAC Mode NAC/Out 1 - with Jumpers J5, JP6, NAC/Out 2 + TB1: Supervised JP7, & JP8 in positions NAG/Out 2 - Earth shown below. NAC/Out 3 + NAC/Out 3- - AC Neutral NAG/Out 4 + AC Hot NAG/Out 4— I I I BOARD LAYOUT IuIiuuuu luuuu luuuu _ J3 uIu,u,uuI... Normally Open Normally Closed Common TB5: Trouble Relay Form Fail-Safe H0 0 (shown energized) IIo 3 2 1 TB5 JPI: Ground Fault P Detection ipi (cut to disable) — J3: ZNAC-4 JP2 Connector JP2 & JP3: Coded/Non-Coded Input Selection C-, [J - [_1J1 0 o Non-Power-Limited J2: To Transformer #2 o Ji: To Transformer #1 000 F1 0) 0 Fl: Battery Fuse 15A,30V _____ D100 1 o - Battery LEDs (L to R): L__ + Battery - AC Power (green) Ground Fault (yellow) JP4: Supervised, Battery Trouble (yellow) Non-Power-Limited • NAC Trouble (yellow) 1B AN, 24 VDC -Charger Trouble/AC Loss (yellow) C.] Auxiliary Output: 10 " - —Aux. Common 500 mA Specific- ___________ Application Power - + Aux. 24 VDC 8 i - - Control input 2 ID 7 t - + Control Input 2 6 - - Out Common 5 i - + Out/Trouble Contact 4 ,. - -Control Input 1 3 - + Control Input 1 2 - - Sync Input SW1 1 - + Sync Input 1 • 1B4 'NOTE: Auxiliary Power Output is power-limited but NOT supervised. SW I: Programming DIP Switches CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0028:225 Page 1 of 1 CATEGORY: Power Units LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FCPS-24S6 and FCPS-24S8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:206 1-24-2003KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 5, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager I .IQ S,Is • July 20, 2004 DN-6820 • 0-123 FDU-80 () N OT I F1 E R® 80-Character Liquid Crystal Display Fire Annunciator Section: Annunciators GENERAL The FDU-80 is a compact, cost-effective, 80 character, backlit LCD Fire Annunciator for use with the NOTIFIER AFP-300, AFP- 400, AFC-600, and NFS-640 Fire Alarm Control Panels (FACPs). The FDU-80 mimics the display of the control panel and dis- plays complete system point status information. Up to 32 FDU- 80s may be connected onto the ElA-485 Terminal Mode port of each control panel. The FDU-80 requires no programming, which saves time during system commissioning. NOTES: The FDU-80 is compatible with the NOTIFIER AFP-300/ 400 Rev. 3.62 or higher, AFC-600 (all revisions), and NFS- 640 Rev. 2.01 or higher. The FDU-80 can be used on the same data loop as the LCD-80/LCD-80TM annunciators revision 1.6 software or higher. FEATURES 80-character Liquid Crystal Display. Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. System status LEDs for Power, Alarm, Trouble, Supervi- sory, and Alarm Silenced. No programming necessary - FDU-80 connects to the terminal mode port. Displays device type identifiers, individual point alarm, trouble or supervisory, zone and custom alpha labels. Time and date display field. Aesthetically pleasing design. May be powered by 24 VDC from the host FACP or by remote power supplies (requires 24 VDC). Up to 32 FDU-80 annunciators per FACP. Plug-in terminal blocks for ease of installation and service. Can be remotely located up to 6,000 feet (1828.8 m) from host control panel. Local piezo sounder with alarm and trouble resound. Semi-flush-mounts to 2.188/5.556 cm (minimum) deep, three-gang electrical box (NOTIFIER P/N 10103) or three- gangable electrical switchbox. Surface-mounts to NOTIFIER SBB-3 surface backbox. OPERATION The FDU-80 annunciator provides the FACP with point an- nunciation with full display text on an 80-character LCD dis- play. The FDU-80 also provides an array of LEDs to indicate system status, and also includes control switches for remote control of critical system functions. California ON State Fire Marshal 128:2O9 LISTED CS100 S635 MEA 245-00-E FDU-80 Annunciator The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Six wires total are required: four for the EIA-485 communica- tions (two in and two return); and two for the 24 VDC regu- lated power. Dip switches control local functions such as: piezo disable, control switches/key switch disable, transmit/ receive mode. INSTALLATION The FDU-80 can be semi-flush mounted to a 2.188/5.556 cm (minimum) deep, three-gang electrical box (NOTIFIER PIN 10103) or three-gangable electrical switchboxes. Alter- nately, an SBB-3 surface backbox is available for surface- mount applications. NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our ISO 9001 product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. 4 I I .1 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ENGINEERING & MMlUFAZ1UIlN NOTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS Made in the U.S.A. DN-6820' 07/20/04 - Page 1 of 2 ORDERING INFORMATION FDU-80 80 character, backlit, LCD Fire Annunciator with control switches for remote control of system functions, and key-switch lock. 10103 Three-gang electrical box, minimum 2.188" (5.556 cm) deep, for semi-flush-mount applications. S1131113-3 Three-gang surface backbox for surface-mount applications. FDU-80 TERMINAL MODE WIRING EXAMPLE Up to 6,000 ft. (1828.8 m) between EACH DEVICE in the EIA-485 loop Terminal Mode /DU0\D80 24 VDC Up to 6,000 ft. (1828.8 m) Terminal Mode / back from last device j to end of EIA-485 loop AFP-400 Notes: EIA-485: Maximum of 6,000 feet (1828.8 m) cable length from FACP to FDU-80 annunciators and back to FACP (6,000 feet [1828.8 m] total). Circuit is power-limited. Up to 32 FDU-80 annunciators may be used on the EIA-485 circuit. When multiple FDU-80s are used, certain panels will require additional power supplies (refer to panel documentation). Between each FDU-80 annunciator are four wires: a twisted-shielded pair for data communications and a pair for 24 VDC power. The return circuit only requires two wires for data communication supervision, wired from the last FDU-80 annunciator on the loop. On the AFP-300/400, software revision 3.62 or higher is required. FDU-80 flange MOUNTING TO BACKBOX(ES) The FDU-80 annunciators can be Mounting semi-flush-mounted in a three-gang electrical box Holes (4) with a minimum depth of 2.188" (5.556 cm) (NOTIFIER P/N 10103). The FDU-80 annunciators can be mounted in three gangable electrical switch boxes connected together. NOTE: Alternately, FDU-80 annunciators can be mounted to the SBB-3 surface backbox for surface-mount applications. 5.813" (14.764 cm) wide x 4" (10.16 cm) high x minimum 2.188" (5.556 cm) deep, three-gang electrical box (NOTIFIER P/N 10103, shown at right). Page 2 of 2 - DN-6820 • 07/20/04 FIRE ALARM ANNUNCIATOR W330 EE- SYSTEMS ALL NORMAL 11: 00 A lION 3.'20'OO -- ___ CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0028:209 Page 1 of 1 CATEGORY: Annunciators LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Model FDU-80 remote fire annunciator. Unit is a compact 80-character, backlit LCD fire annunciator. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciator for use separately listed compatible fire alarm control units. 09-21-2000 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 5, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager June 15, 2005 DN-6995 • Al -310 NOTIFIER® NP-100 and NP-100T by Honeywell Addressable Photoelectric Detectors Section: Addressable GENERAL The NP-100 and NP-100T addressable, low-profile plug- in photoelectric detectors use a state-of-the-art photoelec- tric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWarden-lOO Addressable Fire Alarm Con- trol Panel (FACP). The NP-100T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (PIN RA400Z). FEATURES SL loop: Two-wire loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade 01 - 99 (FireWarden-100) entry of ad- dress. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 4,000 feet-per-minute (20 rn/sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (com- municating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5' (8.89 cm) or 4.0' (10.16 cm) octagonal box, or 4.0 (10.16 cm) square electrical box (using a plaster ring - included). Other system features: Fully coated circuit boards and superior RF/transient Marshal <*> ® California State Fire 7272-0028:231 APPROVED LISTED S1115 MARYLAND M EA State Fire Marshal 243-02-E Vol. II Permit #2173 .\ NP-100 with B71OLP base * NP-lOOT with B710LP base - 6935ph01jpg protection. 94-VO plastic flammability rating. Low standby current. Options: Remote LED output connection (P/N RA400Z). SPECIFICATIONS Voltage range: 15-32 VDC (peak). Standby current: 300 pA @ 24 VDC. LED current: 6.5 mA @ 24 VDC (latched "ON"). Air velocity: 4,000 ft/mm. (20 rn/sec.) maximum. Diameter: 6.1" (15.5 cm) installed in B710LP base. Height: 2.1" (5.33 cm) installed in B71OLP base. Weight: 3.6 oz. (102 g). Operating temperature range: for NP-100: 0°C to 49°C (32°F to 1200F); for NP-100T. 0°C to 38°C (32°F to 100°F). Temperature: 0°C - 49°C (32°F - 120°F). Relative humidity: 10% - 93%, non-condensing. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications ISO 9001 or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 NOTU Fl ER" fIlIGINERING A MNUFWIUIlNC by Honeywell 12 Clintonville Road. Northtord, Connecticut 06472 QUALITY SYSTEMS APPLICATIONS Use photoelectric detectors in life-safety applications to provide a broad range of fire-sensing capability, espe- cially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. CONSTRUCTION These detectors are constructed of off-white LEXAN®. NP-100(T) plug-in, low-profile smoke detectors are de- signed to commercial standards and offer an attractive appearance. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. INSTALLATION NP-100(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: 4.0" (10.16 cm) square box with plaster ring. 4.0" (10.16 cm) octagonal box. 3.5" (8.89 cm) octagonal box. Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring T- taps" or branches are permitted for Style 4 (Class B) wiring. OPERATION Each NP-100(T) uses one of 99 possible addresses on the FireWarden-100 Signaling Line Circuit (SLC). It re- sponds to regular polls from the system and reports its type and status. The NP-100(T) addressable photoelectric sensor's unique unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 rn/sec.) with- out sending an alarm level signal. Because of its unipo- lar chamber, the NP-100(T) is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have its sensitivity tested (required per NFPA 72, Chapter 7 on Inspection, Testing and Mainte- nance) when installed/connected to a FireWarden-100 addressable fire alarm control panel. The results of the sensitivity test can be printed off the FireWarden-100 for record keeping. PRODUCT LINE INFORMATION NP-100 Addressable photoelectric detector; B71OLP base included.* NP-100T Same as NP-100 but with thermal element; B71OLP base included.* RA400Z Remote LED. Mounts to a single-gang box. B71OLP Plug-in detector base. Dimensions: 6.1" (15.5cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224R8 Plug-in System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plas- ter ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224Bl Plug-in System Sensor isolator detector base. Maximum 25 devices between isola- tor bases (see DN-6994). Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B501BH Plug-in System Sensor sounder detector base. Diameter: 6.0" (115.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring. Mounting box has a minimum depth of 1.5" (3.81 cm). Prior to 03/28/05, the B71OLP base was sold separately. Page 2 of 2 - DN-6995 • 06/15/05 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:231 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Notifier, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models NP-100 and NP-100T photoelectric type smoke detectors. Model NP-100T has a 1350F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units. All units are suitable for installation inside air duct with a maximum air velocity of 4000 fpm. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. 7272-0075:194 11-03-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or .. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 5, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0028:236 Page 1 of 1 CATEGORY: Duct Smoke Detector Housing/Base LISTEE: Notifier, 12 Clintonville Rd, Northford, CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Model ND-100 Duct smoke detector. Unit consists of a housing, relay, electrical components, sampling and exhaust tubes and a listed detector head. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. RATING: Air velocity varies between 100 and 4000 fpm MARKING: Listee's name, model number, air velocity rating, and UL label. APPROVAL: Listed as a duct detector unit when used with listee's separately listed compatible fire alarm control units. Suitable for use in ducts where air velocity varies between 100 and 4000 fpm. Refer to listee's Installation Instruction Manual for details. XLF: 3240-1209:155 05-03-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 15, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. A REND, Senior Deputy Program Manager June 15, 2005 DN-7001 - Al -380 NOTIFIER NOT-BG12LX Addressable Manual Pull Station by Honeywell for FireWarden-100 Section: Addressable GENERAL The NOTIFIER NOT-BG12LX is a state-of-the-art, dual- action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for NOTIFIER's addressable FireWarden-100 fire alarm control panel. Because the NOT-BG12LX is addres- sable, the control panel can display the exact location of the activated manual pull station. This leads fire service personnel quickly to the location of the alarm. FEATURES Aesthetically pleasing, highly visible, dual-action design. Meets ADA 5 lb. maximum pull force. Easily operated (dual-action). Attractive shape and textured finish. Mounts, semi-flush, to a standard single-gang (2.125' [5.398 cm] minimum depth), double-gang, or 4.0" (10.16 cm) square electrical box. When the handle latches in down position, the word "AC- TIVATED" appears at the top of the handle in bright yel- low to clearly indicate the station has been operated. Key/lock reset; needs only a 1/4-turn to lock/unlock. Includes Braille text on station handle. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.1 mm2 wire). Optional trim ring (BG-TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Maintenance personnel can open station (for inspection and testing) without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes red in normal operation and latches on steady red when in alarm. ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions pro- vided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-i 0 or SB-I/O; or semi-flush mount- ing on a standard single-gang, double-gang, or 4.0" (10.16 LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. Patented, U.S. Patent No. D428,351; 6,380,846 U.S. Patent Pending: 09/686,286 California State Fire Marshal 7150-0028:199 LISTED S692 APPROVED The NOT-BG12LX Addressable Manual Pull Station cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on com- mand from the control panel, send data to the panel repre- senting the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. ELECTRICAL SPECIFICATIONS Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. MEA 67-02-E Vol. IV This document is not intended to be used for installation purposes. We try to keep our I product information up-to-date and accurate. We cannot cover all specific applications or I anticipate all requirements. All specifications are subject to change without notice. I ISO 9001 I For more information, contact NOTIFIER. Phone: (203) 484-716t FAX: (203) 484-7118 I i Mill NOTI Fl ER' I ENGINEERING K MIINUFAC1IJIINC I by Honeywell 12 Clintonville Road, Northtord, Connecticut 06472 QUALITY SYSTEMS I DN-7001• 06/15/05 - Page 1 of 2 I CD CD CD 3 '4 I TERMINAL CONNECTIONS 1 SLC (-) 2 SLC (~) Back of station without door. Maximum SLC loop current: 230 pA INSTALLATION The NOT-BG12LX can be semi-flush mounted into a single- gang, double-gang, or standard 4.0" (10.16 cm) square elec- trical outlet box, or surface mounted to the Model S13- 10 or SB-I/O surface backbox. If the NOT-BG12LX is semi-flush mounted, then the optional trim ring (BG-TR) may be used. The BG-TR is usually needed for semi-flush mounting with 4.0" (10.16 cm) or double-gang boxes (not with single-gang boxes). CONSTRUCTION Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. OPERATION Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTIVATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bot- tom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action re- sets the handle; closing the door automatically resets the switch. Manual stations connect with two wires to one of the control panel SLC loops. Each manual station, on command from the control panel, sends data to the panel representing the state of the pull station switch. Two rotary decimal switches allow address settings (01-99). PRODUCT LINE INFORMATION NOT-BG1 2LX Dual-action addressable pull station. Includes key lock/reset feature. SB-iD Surface backbox. SB-I/O Surface indoor/outdoor backbox. BG-TR Optional trim ring 0 Detail of BREAKAWAY TAB* e 12 14 151 - Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Page 2 of 2 - DN-7001 • 06/15/05 June 15, 2005 DN-6999 • Al-350 N OT I F I E R® Addressable Monitor Modules for the FireWarden-100: by Honeywell NMM-1 00, NMM-1 00P NZM-1 00, NDM-1 00 Section: Addressable GENERAL Four different monitor modules are available for NOTIFIER's FireWarden-100 intelligent fire alarm control panels to suit a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input de- vices, such as conventional heat detectors and pull sta- tions, or monitor and power a circuit of two-wire smoke detectors (NZM-100). NMM-100 - The NMM-100 Monitor Module is a standard- sized module (typically mounts to a 4.0 [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style 8) circuit of dry-contact input devices. NMM-1 OOP - The NMM-100P is a Miniature Monitor Mod- ule (a mere 1.3° (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D) used to supervise a Class B (Style B) cir- cuit. Its compact design allows the NMM-100P to be mounted in a single-gang box behind the device it is moni- toring. NZM-100 - The NZM-100 Interface Module is a stan- dard-sized module used to monitor and supervise com- patible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. NDM-1 00 - The NDM-1 00 Dual Monitor Module is a stan- dard-sized module (typically mounts to a 4.0" [10.16 cm] square box) that supervises two Class B (Style B) circuits of dry-contact input devices. NMM-100 MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade 01 - 99 (FireWarden-100) entry of ad- dress. LED flashes red during normal operation and latches on steady to indicate alarm. The NMM-100 Monitor Module is intended for use in intel- ligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire Class A or Class B fault-tolerant Initiating Device Circuit (IDC) for normally- open-contact fire alarm and supervisory devices. NIVIM-100 Applications - Use to monitor a zone of four-wire smoke detectors, manual lire alarm pull stations, watertlow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervi- sory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class D) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is re- California State Fire Ui MEA ®Marshal 72-01-E Vol. II ' 7300-0028:230 LISTED (except NDM-100) (except NDM-100) S635 <N> APPROVED NMM-100 and NZM-100 quired for supervision of the Style D circuit. Maximum IDC resistance is 1,500 ohms. NMM-100 Operation - Each NMM-100 uses one of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the con- trol panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 400 pA (LED flashing). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 45" (11.43 cm) high x 4.0' (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4.0° (10.16 cm) square x 2.125" (5.398 cm) deep box. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications ISO 9001 or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 • NOTI El E R° ENGINEERING & MANUFAClIIIINC by Honeywell 12 Clintonville Road. Northford, Connecticut 06472 QUALITY SYSTEMS DN-6999 • 06/15/05 - Page 1 of 3 NMM-100P MINI MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the FireWarden-100. Powered directly by two-wire SLC Loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address (01-99 for FireWarden-100). The NMM-100P Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P is intended for use in in- telligent, two-wire systems where the individual address of each module is selected using rotary switches. It pro- vides a two-wire initiating device circuit for normally-open- contact fire alarm and security devices. 1415 0 1 ADDRESS LOOP 3 12 31 11 4 i 9 8*7 6 6 5_9 8@7 Z TENS ONES k. O Ui 0 o -J -4 UJ -4 0 0:: co N MM-lOOP Applications - Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact devices. May also be used to monitor nor- mally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Cir- cuit. A 47K ohm End-of-Line Resistor (provided) terminates the circuit. N MM-lOOP Operation - Each NMM-100P uses one of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). NMM-100111 Specifications Nominal operating voltage: 15 to 32 VDC. Average operating current: 375 hA maximum. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 491C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.5° (1.270 cm) deep. Wire length: 6.0° (15.24 cm) minimum. Page 2 of 3— DN-6999 • 06/16/0 NZM-100 INTERFACE MODULE Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source (resettable). High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address (01-99 for FireWarden-100). LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The NZM-100 Interface Module is intended for use in in- telligent, addressable systems, where the individual ad- dress of each module is selected using built-in rotary switches. This module allows intelligent panels to inter- face and monitor two-wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL-com- patible with the module. NZM-100 Applications - Use the NZM-100 to moni- tor a zone of two-wire smoke detectors. The monitored cir- cuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or 0 (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style 0 application. NZM-100 Operation - Each NZM-100 uses one of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the con- trol panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 VAMS maximum. Current: 90 mA per module maximum. Requires regulated, resettable 24 VDC power. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4.0" (10.16 cm) wide x 125" (3.175 cm) deep. Mounts to a 4.0" (10.16 cm) square x 2.125° (5.398 cm) deep box. I I NDM-100 DUAL MONITOR MODULE Built-in type identification automatically identifies this de- vice as two monitor modules to the control panel. Powered directly by the two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address 01 - 99 (FireWarden-100) uses two addresses per module. LED flashes red during normal operation and latches on steady red to indicate alarm. The NDM-100 Dual Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides two independent two-wire fault-toler- ant Initiating Device Circuits (lDCs) at two separate, con- secutive addresses. It is capable of monitoring normally open-contact fire alarm and supervisory devices, or either normally open or normally closed devices for non-fire ap- plications. NDM-100 Applications - Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull sta- tions, waterflow devices, or other normally-open dry-con- tact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervi- sory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) Initiating Device Circuit. The 47K ohm End-of-Line Resistors (provided) terminate the Style B circuit. Maximum IDC resistance is 1,500 ohms. NDM-100 Operation - Each NDM-100 uses two of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NDM-100 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 750 pA (LED flashing). EOL resistance: 47K ohms. Maximum IDC wire resistance: 1,500 ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5' (11.43 cm) high x 4.0" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4.0" (10.16 cm) square x 2.125" (5.398 cm) deep box. Accessories: SMB500 electrical box. INSTALLATION NMM-100, NZM-100, and NDM-100 modules mount di- rectly to a standard 4.0" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and in- stallation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power- limited wiring only. The NMM-100P module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances and regulations. ARCHITECTS'/ENGINEERS' SPECIFICATIONS Specifications of these and all NOTIFIER products are available from NOTIFIER. PRODUCT LINE INFORMATION NMM-100 Monitor module. NMM-100P Mini monitor module. NZM-100 Two-wire detector monitor module. NDM-100 Dual monitor module. SMB500 Optional surface-mount backbox. DN-6999 • 06/15/05 - Page 3 of 3 MOUNTING DIAGRAMS For standard-sized modules , CIS i i i t " W-0 ~' >0 June 15, 2005 DN-6999 • Al-350 0 N OT I F I E R® Addressable Monitor Modules for the FireWarden-100: by Honeywell NMM-1 00, NMM-1 OOP, NZM-1 00, NDM-1 00 Section: Addressable GENERAL Four different monitor modules are available for NOTIFIER's FireWarden-100 intelligent fire alarm control panels to suit a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input de- vices, such as conventional heat detectors and pull sta- tions, or monitor and power a circuit of two-wire smoke detectors (NZM-1 00). NMM-1 00 - The NMM-1 00 Monitor Module is a standard- sized module (typically mounts to a 4.0" [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices. NMM-100P —The NMM-100P is a Miniature Monitor Mod- ule (a mere 1.3" (3.302 cm) H x 2.75° (6.985 cm) W x 0.5° (1.270 cm) D) used to supervise a Class B (Style B) cir- cuit. Its compact design allows the NMM-100P to be mounted in a single-gang box behind the device it is moni- toring. NZM-100 - The NZM-100 Interface Module is a stan- dard-sized module used to monitor and supervise com- patible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. NDM-1 00 - The NDM-1 00 Dual Monitor Module is a stan- dard-sized module (typically mounts to a 4.0° [10.16 cm] square box) that supervises two Class B (Style B) circuits of dry-contact input devices. NMM-100 MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade 01 - 99 (FireWarden-100) entry of ad- dress. LED flashes red during normal operation and latches on steady to indicate alarm. The NMM-100 Monitor Module is intended for use in intel- ligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire Class A or Class B fault-tolerant Initiating Device Circuit (IDC) for normally- open-contact fire alarm and supervisory devices. NMM-100 Applications - Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervi- sory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class 0) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is re- California State Fire Marshal ®MEA! 7300-0028:230 72-01-E Vol. II LISTED (except NDM- 100) (except NDM- 100) S635 <@> APPROVED NMM-100 and NZM-100 quired for supervision of the Style D circuit. Maximum IDC resistance is 1,500 ohms. NMM-100 Operation - Each NMM-100 uses one of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IC). A flashing LED indicates that the module is in communication with the con- trol panel. The LED latches steady on alarm (subject to current limitations on the loop). N MM-100 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 400 pA (LED flashing). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4.0° (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4.0" (10.16 cm) square x 2.125" (5.398 cm) deep box. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTtFIER. Phone: (203) 484.7161 FAX: (203) 484-7118 i NOTI Fl E R° ENGINEERING & MNtUFAC11111J by Honeywell 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS DN-6999 • 06/15/05 - Page 1 of 3 NMM-100P MINI MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the FireWarden-100. Powered directly by two-wire SLC Loop. No additional power required. High noise (EMF/RFl) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address (01-99 for FireWarden-100). The NMM-100P Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P is intended for use in in- telligent, two-wire systems where the individual address of each module is selected using rotary switches. It pro- vides a two-wire initiating device circuit for normally-open- contact fire alarm and security devices. 1415 0 i ADDRESS 0 1 12 1 11 LOOP 4 to( 5 9807 TENS ONES N MM-lOOP Applications - Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact devices. May also be used to monitor nor- mally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Cir- cuit. A 47K ohm End-of-Line Resistor (provided) terminates the circuit. N111111111011-100112 Operation - Each NMM-100P uses one of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). NMM-100P Specifications Nominal operating voltage: 15 to 32 VDC Average operating current: 375 pA maximum. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensirig. Dimensions: 1.3° (3.302 cm) high x 2.75° (6.985 cm) wide x 0.5 (1.270 cm) deep. Wire length: 6.0° (15.24 cm) minimum. Page 2013— DN-6999 • 06/15/05 NZM-100 INTERFACE MODULE Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source (resettable). High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address (01-99 for FireWarden-100). LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The NZM-100 Interface Module is intended for use in in- telligent, addressable systems, where the individual ad- dress of each module is selected using built-in rotary switches. This module allows intelligent panels to inter- face and monitor two-wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL-com- patible with the module. NZM-100 Applications - Use the NZM-100 to moni- tor a zone of two-wire smoke detectors. The monitored cir- cuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. NZM-100 Operation - Each NZM-100 uses one of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the con- trol panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 VRMS maximum. Current: 90 mA per module maximum. Requires regulated, resettable 24 VDC power. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% rroncondensing. Dimensions: 4.5° (11.43 cm) high x 4.0° (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4.0° (10.16 cm) square x 2.125° (5.398 cm) deep box. NDM-100 DUAL MONITOR MODULE Built-in type identification automatically identifies this de- vice as two monitor modules to the control panel. Powered directly by the two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address 01 - 99 (FireWarden-100) uses two addresses per module. LED flashes red during normal operation and latches on steady red to indicate alarm. The NDM-100 Dual Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides two independent two-wire fault-toler- ant Initiating Device Circuits (lDCs) at two separate, con- secutive addresses. It is capable of monitoring normally open-contact fire alarm and supervisory devices, or either normally open or normally closed devices for non-fire ap- plications. NDM-100 Applications - Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull sta- tions, waterfiow devices, or other normally-open dry-con- tact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervi- sory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) Initiating Device Circuit. The 47K ohm End-of-Line Resistors (provided) terminate the Style B circuit. Maximum IDC resistance is 1,500 ohms. NDNI-100 Operation - Each NDM-100 uses two of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NDM..100 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 750 pA (LED flashing). EOL resistance: 47K ohms. Maximum IDC wire resistance: 1,500 ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4.0" (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4.0° (10.16 cm) square x 2.125" (5.398 cm) deep box. Accessories: SMB500 electrical box. INSTALLATION NMM-100, NZM-100, and NDM-100 modules mount di- rectly to a standard 4.0° (10.16 cm) square, 2.125° (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and in- stallation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power- limited wiring only. The NMM-100P module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances and regulations. ARCHITECTS'/ENGINEERS' SPECIFICATIONS Specifications of these and all NOTIFIER products are available from NOTIFIER. PRODUCT LINE INFORMATION NMM-100 Monitor module. NMM-100P Mini monitor module. NZM-100 Two-wire detector monitor module. NDM-100 Dual monitor module. SMB500 Optional surface-mount backbox. 1' I HO9 MOUNTING DIAGRAMS For standard-sized modules DN-6999 • 06/15/05 - Page 3 of 3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:230 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, 12 Clintonville Rd, Northford CT 06472 Contact: Lawrence Flood (203) 484-1200 Fax (203) 484-7309 DESIGN: Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-1 00 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:185 10-20-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 5, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. A REND, Senior Deputy Program Manager June 15, 2005 DN-7000 • Al-360 NC-100 and NC-i OOR N OT I F I E R® Control and Relay Modules by Honeywell for the FireWarden-100 Section: Addressable GENERAL The NC-100 Addressable Control Module provides NOTIFIER's FireWarden-100 intelligent control panels a su- pervised Class B (Style Y) or Class A (Style Z) circuit for Noti- fication Appliances (horns, strobes, etc.). Addressability al- lows the NC-100 to be activated, either manually or through panel programming, on a select (zone or area of coverage) basis. The NC-100R Addressable Relay Module provides the FireWarden-100 system with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary de- vices, such as fans, dampers, door holders, control equip- ment, etc. Addressability allows the dry contact to be acti- vated, either manually or through panel programming, on a select basis. FEATURES Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The NC-100 module requires power (for horns, strobes, etc.). Integral LED 'blinks" green each time a communication is received from the control panel and turns on steady when activated. High noise immunity (EMF/RFl). The NC-100 may be used to switch 24-volt NAC power. Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct Decade 01-99 (FireWarden-100) entry of address. APPLICATIONS The NC-100 is used to switch 24 VDC audible/visual power. The NC-100R may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc. CONSTRUCTION The face plate is made of off-white Noryl®. Controls include two rotary switches for direct-dial entry of address (01-99 on the FireWarden-100). The NC-100 is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The NC-100R provides two Form-C dry contacts that switch together. OPERATION Each NC-100 or NC-bOA uses one of 99 (FireWarden- 100) possible module addresses on a SLC loop. It re- sponds to regular polls from the control panel and reports its type and status, including the open/normal/short sta- tus of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates California State Fire MEA ul iC.) Marshal 72-01-E Vol. II 7300-0028:230 LISTED S635 <*> APPROVED NC-100 and NC-100R module its internal relay. The NC-100 supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the NC-100 will dis- connect the supervision and connect the external power supply in the proper polarity across the load device. The disconnection of the supervision provides a positive indi- cation to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the communication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the control panel, so as to differentiate between a mod- ule and a sensor address. Noryl® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or I I ISO 9001 I anticipate all requirements. All specifications are subject to change without notice. I For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 I .i i i i I N OTI Fl E R ENGINEEIINC A MNUFACl111lfL I by Honeywell 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS I DN-7000 • 06/15/05 - Page 1 of 2 SPECIFICATIONS FOR NC- 100 Normal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 390 pA (LED flashing). External supply voltage (between Terminals T3 and T4): maximum 80 volts (RMS or DC). Drain on external supply: 2 mA maximum (using internal EOL relay). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4.00 (10.16 cm) wide x 1.250 (3.175 cm) deep. Mounts to a 4.0° (10.16 cm) square x 2.125" (5.398 cm) deep box. SPECIFICATIONS FOR NC-700R Normal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 450 (11.43 cm) high x 4.0° (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4.0° (10.16 cm) square x 2.125° (5.398 cm) deep box. PRODUCT LINE INFORMATION NC-100 Intelligent addressable control module. NC-bOA Intelligent addressable relay module. SMB500 Optional surface-mount backbox. CB500 Control module barrier - required by UL for separating power-limited and non-power lim- ited wiring in the same junction box as NC-1 00. RELAY CONTACT RATINGS for both con frol and relay models Load Description Application Maximum Voltage Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/Fl = 5 ms) Coded 30 VDC 0.5 A lrKlixtive (L/R = 2 ms) Coded 30 VDC 1.0 A Inductive (PF = 0.35) Non-Coded 125 VAC 0.5 A 6724 '8 0. '81 iii MOUNTING DIAGRAMS Note CB500 Module Barrier, which creates isolated quadrant ISOLATED QUADRANT Page 2 of 2 - DN-7000 • 06/15/05 SERIES AS SERIES AH eeod - J7 MEA ADA Helping People Take Action SERIES AS SINGLE & MULTI-CANDELA AUDIBLE STROBE APPLIANCES SERIES AH AUDIBLES Description Wheelock's patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or Wheelock's patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/110cd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30175195cd or the high intensity MCCH strobe with field selectable 115/1 77cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM or DSM Sync Module or Wheelock PS-12/24-8CP and PS-12/24-8MP Power Supplies with Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. For Weatherproof Series AS, See Datasheet S9004 Copyright 2004 Wheelock Inc. All rights reserved. av Multi-Candela Indicator (bottom of lens) Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information. ADA/NFPA/UFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi-Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15/30/75195cd or 115/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage The strobes can be synchronized using Wheelock's sync modules or power supplies with built in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of ito 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series AS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 93% (± 2%). Series AH-24 horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). Series AH-24WP audible appliances are listed under UL Standard 464 for indoor/outdoor use with a temperature range of -31°F to 150°F (-35°C to 66°C) and maximum humidity of 95%. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1911 Model Input Voltage VDC Regulated Voltage Range VDCIFWR Strobe Candela (Cd) AS-24McW 24 16.0-33.0 15/30115/110 As-24MccH 24 16.0-33.0 115/177 AS-241575W 24 16.0 -33.0 15 (75 on A)ds) AS-121575W 12 8.0- 17.5 15175 on Aids) AS-24MCC 24 16.0-33.0 15/30/75/95 AS-24MCWH 24 16.0-33.0 135/185 ASWP-2475W 24 16.0-33.0 75@-31°F Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS!AH 12 and 24 VDC Audible Description Volume Reverberant dBA Anechoic Per UL464@lOft. dBA @lOft. High 91 99 Medium 88 95 Conlinuois Horn Low 83 90 High 87 99 Medium 84 95 Code 3 Horn Low 79 90 Table 3: Average RMS Current Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models 24 VDC Models AH-24 AS-241575W AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 24 vdc 0.062 0.100 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 High (99) dBA ULmax* 0.080 0.121 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 Med 24 vdc 0.033 0.080 0.060 1 0.084 0.132 0.173 0.230 1 0.305 1 0.066 0.092 0.145 0.186 0.230 1 0.305 (95) dBA UL max* 0.043 0.107 0.074 0.110 0.190 0.253 0.340 1 0.465 1 0.080 1 0.122 0.201 0.269 1 0.340 0.465 24 vdc 0.017 0.072 0.052 1 0.076 0.121 1 0.158 0.220 1 0.295 1 0.056 0.082 0.132 0.173 0.220 0.295 Low (90) dBA UL max* 0.021 1 0.100 1 0.068 1 0.105 0.182 1 0.245 0.335 1 0.460 1 0.074 0.113 0.198 0.263 0.335 0.460 12 VDC Models AudibleWall Mount Audible Strobe RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16- 33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. AH-12 AS-121575W High (99) dBA 12 vdc 0.163 0.260 UL max* 0.192 0.320 Med (95) dBA 12 vdc 0.076 0.195 UL max* 0.108 0.275 Low (90) dBA 12 vdc 0.039 0.175 UL max* 0,058 0.265 A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P83947) SERIES AS-24MCW, (P84023 AND P84024) SERIES AS SINGLE CANDELA, (P83519) Seles AH, (P83641) Series AH-WP AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. THESE APPLIANCES ARE NOT DESIGNED TO BE USED ON CODED SYSTEMS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams il SERIES AS APPLIANCES NON-SYNCHRONIZED FROM TO NEXT PRECEDING APPLIANCE APPLIANCE _LLLL OR EOLR OR FACP 1!I1 SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A" NAG CIRCUIT WITH NO AUDIBLE SILENCE FEATURE DUAL SYNC MOO(AE ØSThC OSVNC P __ k_MNUSA cIRCUT TlAO SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAG CIRCUIT WITH AUDIBLESILENCE FEATURE STROBE STROBE A NAC Circuit EOLR Audible 'Audible NAC Circuit SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES Audible NAC Cit. DSM #1 Strobe NAC Ci,. Sync iiII F rt1_J T Audible NAC Ci' DSM #2 A Strobe MAC Cit1 I __AS 3 C Audible MAC Cl, I DSM #3 Sirsbe MAC Cr1 Sync AS AS 111 I iiiJIII DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12/24-8CP and PS-12/24-8MP I I 14 I I OUTPUTS N EOLR A.Cl.ASS OR C I 2-CLASS Sn PS.l2J2o.00P ° For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS-12/24-8CP and P84333 for PS-12/24-8MP. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS-12/24-8CP or PS-12/24-8MP Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. Specifications and Ordering Information Model Order 0 e d Strobe Candela Non-Sync Sync wISM. OSM PS-12124-8cP or PS -12124 24 VDC 12 VDC Wall M I OUfl M OUfl Ceiling Agency Mounting Options Approval s - UL MEA CSFM FM - BEP AS-24MCW-FR 9024 15/30175/110 X X X . X . A,B,D.E,F.(H,J,N.O.RX X X X X X AS.24MCW-FW 9025 15130/75/110 X X X - X[ A.B,D.C,F,GH,J.N,O,X X X )( X X AS-24MCWH-FR 3468 135/185 x x x - X - A,B,D,E.F,cl-t,J,t'I,ORX K X X X - * - AS-24MCW1-l-FW 3469 135/185 X x x - X - A,B,D.E.F,cl-I.J,N.O.RX X x X X * AS-241575W-FR AS-121575W-FR 7405 7410 15 (75 on Aós) 15 (75 on Ads) X X K X X - . X X X- . A.B,D,E,F,w1.J,N.0.RX A,BD,E,F.cH.J,N.O,RX X X x X X K K X K X AS-24MCC.FR 3161 15130115/95 X X X . . X A.B,D.EF,(HJ.N,O,R.X x x X X * As-24Mcc-Fw 3162 15/30/75/95 X x x . - x A,BD,E,F.OH,J.N,O,R,X x x x x AS-24MCC11-FW 3467 115/177 X x x . - K A,B4O,E,FH.J,NO.R,X x x x X * ASWP-2475W-FR 9012 75 @ -31F X X K - x r - I (see Data Sheet S9004) X X K X I X' AH-24-R 7892 - x x x . X K A.B.D,E,F,GH,J,N,O,R,X X X x X X AH-24-W 7893 . X x x . x x A,B,D,E,F.OH,JN,O,R.X x x x x X AH-12-R 7891 - x x - x x x A,B,D,E,F,(I1,J,N,o,Rx K X x x X At02-W 7894 - X X - X X K A,B.D.E,F.Gj-t,J,N.O,R.X X X X x X AH-24WP-R'*7416 - X X X . X X K X x x x AH-R" 7415 . X X [ . X X X K X X X X PENDING Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. "For Weatherproof Series AS/AH specifications see data sheet S9004. Refer to Data Sheet S7000 for Mounting Options. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION 3 YEAR WARRANTY Made in USA NATIONAL SALES OFFICE 1-800-631-2148 Canada 800 397-5777 MENZA E-mail: lnfo@wheelockinc.com http://www.wheelockinc.com I ThI Distributed By: WHEELOCK, INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 • 732-222-6880 • FAX: 732-222-2588 S810001105 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP*2475W is also suitable for outdoor use when mounted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix W are for wall mount only. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFR Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MCW: Selectable 15cd, 30cd, 75cd, 110cd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd MCCH: Selectable 115cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -C are for ceiling mount only. Corrected 08-20-04 Listing No. 7125-0785:131 Page 2 of 2 MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- 12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. Corrected 08-20-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ./.. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to Iistee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 21, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager M rr E'AADA UL Helping People Take Action'" SERIES RSS & RSSP SINGLE & MULTI-CANDELA STROBES & STROBE PLATES DESCRIPTION Wheelock's patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or Wheelock's Patented MCW multi-candela strobe with field selectable candela settings of 15130175/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules or the PS-12124-8CP and PS-12124-8MP Power Supplies with Wheelock's Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72, Wheelock's Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1 00m European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with Wheelock's SBL2 surface backbox. For Weatherproof Series RSS See Datat sheet S9004 Copyright 2004 Wheelock, Inc. All rights reserved. New Look p Series RSS Series RSSP RSS Round * LJ Multi-Candela Indicator (bottom of Strobe Lens) Features Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADNNFPAJUFC/ANSI compliant. Meets OSHA 29 Part 1910.165 Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30! 75/110cd or 1351185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15130175!95cd or 1151177cd. (Round or Square) Strobes produce I flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage" using filtered (DC) or unfiltered VRMS input voltage Synchronize using Wheelock's sync modules or power supplies with built-in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire NOTE: All CAUTIONS and WARNINGS are identified by the symbol. All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 t 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series RSS & RSSP Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 93% (± 2%). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSS/RSSP - Walt Mount RSS - Ceiling Mount RSS/RSSP 241575W 24MCW 24MCWH 24MCC 24MCCH Models 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 11 5c 177cd 24vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270 UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 1 0.065 0.105 0.189 0.249 0.300 0.420 RSS/RSSP RSS/RSSP * RMS current ratings are per UL average RMS method. UL max current 24VDC Wall Mountrating is the maximum RMS current within the listed voltage range (16-33v 121575W Models for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, 12 vdc 0.152 see installation instructions. UL max 0.255 Table 2: Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6/G10 Speakers ET-1010/1080, E70, ET70 Chimes CH70 WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE. POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBES ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBES MAY NOT FLASH. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams 11 SERIES RSS/RSSP APPLIANCE FROM + TO NEXT PRECEDING APPLIANCE APPLIANCE, SYNC OR EOLR MODULE, POWER - SUPPLY OR FACP SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE NAC SYNC + CIRCUIT - 0 OUT eOUT 1 0IN1 RSS RSS RSS 0 MINUS 1 0+ ]ROBE AUDIBLE 2 ØMINUS 0 + IN 2 RSS RSSRSS NAC 0 * OUT 2 CIRCUIT RETURN :/PLATE ASSEMBLY & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM _____ APPLIANCE PRECEDING OR EOLR APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP STROBE AUDIBLE STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY FROM + + TO woo PRECEDING I I APPLIANCE APPLIANCE OR - I I OR EOLR FACP SERIES RSS/RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM F + STROBE 0 - STROBE Strobe A NAC Circuit D+Audibj AUdib SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 eNACCir.Sync r1IV-f- I I I I — RSS F r DSM #2 A Strobe NAG Cir. RSS RSS C DSM #3 Sync StrobeNACCir.I H I (,RSS) RSS) DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH PS-12124-8CP or PS-12/24-8MP Series PS-12124-8MP OUTPUTS EOLR F 1-4 - 4-CLASS A OR AS SS C 2-CLASS P AS RSS Series PS-12/24-8MP FROM + + TO NEXT PRECEDING STROBE OR - STROBE. SYNC - - - •11 EOLR 1 1 MODULE. POWER - - f - SUPPLY ORFACP STROBE APPLIANCE For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS-12/24-8CP and P84333 for PS-12/24-8MP. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC). Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Enaineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS-12124-BCP and PS- 12/24-8MP Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. Specifications and Ordering Information Model Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE * Mounting Options Square or Round Agency Approvals - UL MEA CSFM - FM - BFP RSS-24MCW-FR 940 X - X 15/30/75/110 X - X - B4O,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCW-FW 9401 X - X 15/30/75/110 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FR 7471 X - X 15(75onAxis) X - X - B,D,E,F,G,H,J,N,O,R,X Square X I X X X X RSS-241575W-FW 7788 X - X 15(75onAxis) X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FR 7476 X - X 15(75onAxis) - X X - B4O,E,F,G,H,JN,O,R,X Square X X X X X RSS-121575W-FW 7468 X - X 15(75onAxis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCC-FW 3158 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G.H,J,N,O,R,X Square X X X X * RSS-24MCCR-FW 3160 - X X 15/30/75/95 X - - X B,D,E.F,G,H,J,N,O,R,X Round X X X X RSS-24MCCH-FW 3461 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCCHR-FW 3463 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X * RSS-24MCWH-FR 3465 X X 135/185 X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSWP-2475W-FR 9013 X - X 180@ 77'F X X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSWP2475WFW** 3034 X - X 180@ 77-F X X - X B,D,EF,G,H,J,N,O,R,X Square X X X X * RSSP-121575W-FR 7798 X - X 15(75onAxis) - X X - D,E,Z Square X X X X X RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X X X X RSSP-241575W-FR 7793 X - X 15(75onAxis) - - X - D,E,Z Square X X X X X RSSP-24MCWH-FR 9482 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X * * All models sync with Wheelock SM, DSM or PS-12/24-8CP or PS-12/24-8MP. *PENDING # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION 3 YEAR WARRANTY NATIONAL SALES OFFICE Made in USA Distributed By: 1-800-631-2148 FOC MWAW 00 Canada 800 397-5777 MEM E-mail: Info@wheelockinc.com http://www.wheelockinc.com WHEELOCK, INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 • 732-222-6880 • FAX: 732-222-2588 S041003/06 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ, 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 24100 24100 24100 24100 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, *RSS24MCWH *RSS24MCWHR *RSSP24MCWH *RSS24MCCH *Rss 24MCCHR, and *RSSP..24MCCH Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 = 1 6-33VDC/FWR Candela 15=5cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110=110cd (Wall) RSS-24MCW, RSSP-24MCW--Selectable 15cd, 30cd, 75cd or 110cd RSS-24MCC, RSS-24MCCR and RSSP-24MCC - Selectable 15cd, 30cd, 75cd and 95cd *RSS24MCWH *RSS24MCWHR, *RSSP24MCWH - Selectable 135cd, 185cd *RSS24MCCH *RSS24MCCHR, *RSSP24MCCH —Selectable 115cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix —W, wall mount only. Models with suffix —C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. Rev. 02-03-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ,. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 21, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager .t• I H -lot - jj SSK451 UL S2522 E:I •.D SSK451 with PS24LOW strobe and P512/24LENSW 'SMOKE' lens - - F LEJ PA400 with PS24LOW add-on strobe Models Available A PA 451 RA400Z RTS451 RTS451KEY SSK451 PA400R PA 400W PS24LO PS24LOW PS12/24SLENSW Piezo Annunciator Remote Annunciator Remote Test Station Remote Test Station with Key Multi-Signaling Accessory Mini-Alert Sounder (red) Mini-Alert Sounder (white) Mini-Alert Add-on Strobe (red) Mini-Alert Add-on Strobe (white) Wall-Mount 'SMOKE" Lens ______ I ' p_ APA451 UL S4011 Product Overview RA400Z UL S2522 System Sensor provides system flexibility with a variety of accessories, including three remote test devices and several different means of visible and audible system annunciation. Like System Sensor's duct detectors, all duct smoke detector accessories are UL listed. APA451 The APA451 provides a red alarm LED, with an audible annunciation of an alarm signal, and a green power LED. It is intended for use in System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply with NFPA 90A. RA400Z The RA400Z remote annunciator is designed for both conventional and intelligent applications. The red LED provides visual indication of an alarm condition. RTS451 and RTS451KEY The RTS451 and RTS451 KEY are automatic fire detector accessories designed to test remotely locat- ed duct detectors. For 4-wire detectors, the RTS45 1 KEY features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. SSK451 The SSK45I multi-signaling accessory is designed for use with System Sensor 4-wire conventional duet smoke detectors. It combines a horn feature with the key-activated test and reset functions. Green, amber and red LEDs provide visual indication of power, trouble and alarm conditions, respectively. PA400R and PA400W The PA400 models are 90dRA pulsed sounders for applications where a smaller notification device is required. The PS241-0 and PS24LOW add-on strobes can he attached for visual alarm signaling. PS24LO and PS24LOW The PS24LO and PS241..OW strobes can be attached to the PA400 or SSK45I for visual alarm signaling. The PSI2/24SLENS\V "SMOKE" lens is available to meet special code requirements in certain jurisdictions. & 0LISTED RTS451 UL S2522 RTS451KEY UL 52522 APA451 Specifications RTS45I Specifications SSK451 Specifications Voltage Power Requirements Voltage Regulated 24VDC Alarm LED: 2.8-32VDC, lOmA max. 24VDC Operating Voltage Total Current: 105mA max. Power Requirements 16-33VDC Test Switch Standby: 8mA 10VA @ 32VDC Trouble: 16mA M ax mUm Alarm Current 30mA Reset Switch Alarm without strobe: 40mA Alarm with strobe: 65mA Temperature Range 1OVA @ 32VDC —10°C to 38°C (14°F to 100°F) Alarm Response Time Sounder 87dBA at ten feet 40 seconds max. Relative Humidity 95% non-condensing Temperature Range Terriperature Range —10°C to 60°C (14°F to 140°F) Wire Gauge -10°C to 60°C (14°F to 140°F) 14 to 18AWG Relative Humidity Relative Humidity 95% non-condensing Dimensions 95% non-condensing 4.6"H x 2.75W x 1.5"D Wire Gauge Wire Gauge 14 to 18AWG 14 to 22AWG PA400 Specifications Dimensions Dimensions Voltage 4.6"H X 2.75"W X 1.8"D 4.8"H x 4.7°W x 1.5"D 12/24VDC Temperature Range PS24LO Specifications RTS45IKEV Specifications -10°C to 60°C (147 to 140°F) Voltage Power Requirements 24VDC Power LED (Green): 14-35VDC, 12mA max. Wire Gauge Alarm LED (Red): 2.8-32VDC, 7.5mA max. 12 to 18AWG Temperature Range Total Current: 103mA maximum Dimensions 0°C to 49°C (32°F to 120°F) Alarm Response Time 4.6" x 2.8" x 1.4" Wire Gauge 40 seconds maximum 12 to 18AWG Temperature Range RA400Z Specifications Dimensions —10°C to 60°C (147 to 140°F) Voltage Range 3.8" x.1.6" x 1.6" Relative Humidity Conventional System: 3.1 to 32VDC 95% non-condensing Intelligent System: 18 to 32VDC Wire Gauge Maximum Alarm Current 14 to 18AWG lOmA Dimensions Dimensions 4.6"H x 2.75W x 1.8"D 4.6" x 2.8" x 1.3" For the very latest product specifications, please visit the System Sensor web site at www.systemsensor.corn. System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor In China System Sensor - Far East System Sensor - India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.011.9 Ph: 85.22.191.9003 Ph: 91.124.237.1770 x.2700 St. Charles, IL 60174 Fx: 905.812.0771 Fr: 86.29.8832.5110 Fx: 8522736.6580 Fe: 91.124.237.3118 Ph. 800/SENSOR2 System Sensor Europe System Sensor In Singapore System Sensor - Australia System Sensor - Russia Fr. 630/377-6495 Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 www.systernsensor.com Fe: 44.1403.891921 Fx: 65.6273.2610 Fr: 613.54.281.172 Fe: 70.95.937.7983 SI 2004 System Sensor. The company reserves the right to change product specifications without notice. A05-0375-000-06/04 -#1291 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: NOTE: 7300-1653:110 Page 1 of 1 Misc. Devices/Control Unit Accessories System Sensor, Unincorporated Div of Honeywell Int'l Inc., 3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 Models RTS451 and RT5451 KEY remote test switches, and Model RIG remote test station kit. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number and UL label. Listed as accessory devices for use with separately listed compatible duct smoke detectors. Formerly 7300-0087:129, 7300-1209:129 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 17, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager JJ AQ226 Aquaseal Water Resistant Cable Rev. 2. 1/02 Power Limited Tray Cable - 300volts Description: Multiple conductor unshielded ASTM Bare Copper PVC Insulation with Nylon One pair Unshielded Waterbiocked construction (Overall two ply waterblocking tape) Overall Sunlight and Moisture resistant PVC Jacket Rating as per NEC: UL listed Direct Burial NEC EPI or PITC Constructed in accordance with UL Standard 1424 and 13 Complies with U11581 vertical tray flame test Meets 300 volts requirements as specified in Article 125 and 760 of the NEC Exceeds TlA455-82B Water infiltration test Applications: Materials suitable for outdoor use, indoor trays, and non-conduit per NEC: low-voltage Industrial Process Control Circuits Power-limited Circuits Power-Limited Fire Alarm Circuits Power-Limited Tray Cable PITC Color Code: 1. Black, 2. Red Jacket Color: Black Special Notes: Orange ripcord under jacket Aquaseal Water Resistant Cable- Registered trademark of West Penn Wire P;'w1 'h '117111 2833 West Chestnut Street Washington, PA 15301 www.westpenn-cdt.com e-mail: wpwsales@westpenn-cdt.com Number of Conductors Construction 2 AWG Size 14 Stranding 19x27 Nom. Insulation Thickness .015 inch (.38 mm) PVC .005 inch (.13mm) Nylon Nom. Jacket Thickness .040 inch (102mm) Nominal O.D. .310 inch (7.87 mm) Nom. Capacitance 32pf/ft (lO5pf/m) DC Resistance 2.7Q per 1000ft This document is the property of WEST PENN WIRE. The information con- tained herein is considered proprietary and not to be reproduced by any means without written consent of WEST PENN WIRE. 724-222-7060 FAX: 724-222-6420 TOLL FREE: 800-245-4964 PA CALL: 800-222-8883 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No: CATEGORY: LISTEE: DESIGN: INSTALLATION MARKING: APPROVAL: 7161-0859:101 Page 1 of 1 Cables-Fire Protective Signaling West Penn Wire, P0 Box 762, Washington PA 15301 Contact: *Diane Kelley (724) 222-7060 Types FPL and FPLP power limited fire protective signaling cable. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, NEC Article 760, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, type, NEC rating and UL label. Listed as power-limited fire protective signaling cable. 'Rev. 06-17-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation I criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 21, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager FEB 20 2006 7:33AM FASTERCABLE 7024568389 p.1 fastercable phone 702-456-8900 eve fax 866-462-6978 just inime cbnqdco ieppy Products for the Controls Installation FAX o Urgent or review 0 Please comment 0 Please reply 0 Please recycle To From Fax .-7v.7Lf7.. 7.S6/ Pages Phone Date ,. —1.4 —Dc C4L&f S,zC'J Subject cc ,v ,g10 t 'J r.—ØLA4L fastZble phone 702-456-8900 fax 866-462-6978 just in time cab5rç a..d coMwl,pph) Products for the Controls Installation FIL)( 0 Urgent jfor review 0 Please comment 0 Please reply 0 Please recycle To /.rEL From Fax - '7Y7- 7S61 Pages Phone Date 5L -, Subject CC #D1Ovv j 81361319i'20L I138E1sEjj wuE:it 900 81 Hd FEB 20 2006 7:33AM FASTERCABLE 7024568989 p.2 - (s3B COMPANY: JUST IN TIME/FASTER CABLE DATE: 02/20/06 SPECIFICATION SHEET TWC PART NUMBER: 1480BB2/FPLR CONSTRUCTION : 14AWG SOLID BARE COPPER 2 CONDUCTORS. COLOR CODE : BLK/RED INSULATION : 0.0130 Inch, 75 SR-PVC SHIELD/DRAIN : N/A CAPACITANCE : 32 pF/ft Nom. VEL OF PROP : 55% IMPEDANCE : 58 OHMS D.C. RESISTANCE: 2,525 OHMS PER 1000 FT @ 68 DEG. F TEMP/VOLTAGE : 75 C/300 VOLT JACKET : 0.0200 Inch, PVC -- 0.220 Nom OD. APROX CABLE WT: 36.99 Lb/1000Ft (EXCLUDING REEL OR BOX) PRINT LEGEND : AS DESIRED 2/20/2006 FEB20 2006 7:33AM FASTERCABLE 7024568983 p.3 +1- 10% Manufacturing tolerance * On non-standard product, customer agrees to accept all lengths manufactured APPROVED BY 2/20/2006 FEB 20 2006 7:34AM FASTERCABLE 7024568989 p.8 (s3B COMPANY: JUST IN TIME/FASTER CABLE DATE: 02/20/06 SPECIFICATION SHEET TWC PART NUMBER: I 880BB2/FPLR CONSTRUCTION : I8AWG SOLID BARE COPPER 2 CONDUCTORS. COLOR CODE : BLKJRED INSULATION : 0.0100 Inch, 75 SR-PVC SHIELD/DRAIN : N/A CAPACITANCE : 29.2 pF/ft Nom. VEL OF PROP : 55% IMPEDANCE : 63 OHMS D.C. RESISTANCE: 6.385 OHMS PER 1000 FT @ 68 DEG. F TEMP/VOLTAGE : 75 C/300 VOLT JACKET : 0.0200 Inch, PVC -- 0.16 1 Nom OD. APROX CABLE WT: 17.60 Lb/1000Ft (EXCLUDING REEL OR BOX) PRINT LEGEND : AS DESIRED 2/20/2006 FEB20 2006 7:34AM FASTERCABLE 7024568989 p.9 * +1- 10% Manufacturing tolerance * On non-standard product, customer agrees to accept all lengths manufactured APPROVED BY 2/20/2006 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-1384:101 Page 1 of I CATEGORY: Cables-Fire Protective Signaling LISTEE: Tappan Wire & Cable, 256 Oak Tree Rd., Tappan NY 10983 Contact: *j5 Durland (845) 353-9000 FAX (845) 353-9315 DESIGN: Types FPL, FPLP and FPLR power-limited fire protective signaling cables. Refer to Iistees data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. *Rev. 04-20-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test ' results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the Item listed. This listing should not be used to verify correct operational requirements or installation UVJ criteria. Refer to listees data sheet, installation instructions and/or other suitable Information sources. Date Issued: APRIL 20, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager 886899b'20L 319bJ3?I1SEJJ Wd8E:1 9002 01 AbJW FEB20 2006 7:33AM FASTERCABLE 7024568989 p.6 (s3B COMPANY: JUST IN TIME/FASTER CABLE DATE: 02/20/06 SPECIFICATION SHEET TWC PART NUMBER: 1880BB2/FPLP CONSTRUCTION : I8AWG SOLID BARE COPPER 2 CONDUCTORS. COLOR CODE : BLKJRED INSULATION : 0.0090 Inch, LOW SMOKE PVC SHIELD/DRAIN : N/A CAPACITANCE : 30.6 pF/ft Nom. VELOF PROP : 55% IMPEDANCE : 60 OHMS D.C. RESISTANCE: 6.385 OHMS PER 1000 FT ® 68 DEG. F TEMP/VOLTAGE : 75 C/300 VOLT JACKET : 0.0140 Inch, PVC -- 0.145 Nom OD. APROX CABLE WT: 16.24 Lb/1000Ft (EXCLUDING REEL OR BOX) PRINT LEGEND : AS DESIRED 2/20/2006 FEB 20 2006 7:34AM FASTERCABLE 7024568989 p.7 * +1- 10% Manufacturing tolerance * On non-standard product, customer agrees to accept all lengths manufactured APPROVED BY 2/20/2006 FE120 2006 7:33AM FASTERCABLE 7024568989 (s3B COMPANY: JUST IN TIME/FASTER CABLE DATE: 02/20/06 SPECIFICATION SHEET TWC PART NUMBER: 1480BB2/FPLP CONSTRUCTION : 14AWG SOLID BARE COPPER 2 CONDUCTORS. COLOR CODE : BLKIRED INSULATION : 0.0120 Inch., LOW SMOKE PVC SHIELD/DRAIN : N/A CAPACITANCE : 33.3 pP/ft Nom. VELOF PROP : 55% IMPEDANCE : 56 OHMS D.C. RESISTANCE: 2.525 OHMS PER 1000 FT @ 68 DEG. F TEMP/VOLTAGE : 75 C/300 VOLT JACKET : 0.0140 Inch, PVC -- 0.204 Nom OD. APROX CABLE WT: 35.37 Lb/i 000Ft (EXCLUDING REEL OR BOX) PRINT LEGEND : AS DESIRED 2/20/2006 FEB20 2008 7:33AM FASTERCABLE 7024568889 p.5 * +1- 10% Manufacturing tolerance * On non-standard product, customer agrees to accept all lengths manufactured APPROVED BY 2/20/2006 W erket. 14e Xer. AGM Sealed Lead Acid Battery 04044 Werker SLA Absorbed Glass Mat (AGM) construction is designed for efficient gas recombination and maintenance-free operation. Werker SLA batteries contain heavy-duty lead calcium tin alloy grids, which provide extra margin of performance and service life in cycle applications. The construction and sealing techniques guarantee leak-proof operation regardless of the battery's position. Item Number Volts Flame Retardant Capacity AH/20HR Dimensions (in.) L W H Height Over Terminal Weight jibs.) Price WKAl2-0.8WL 12 No 0.8 3.78 0.98 2.40 0.09 0.75 $0.00 WKAl2-1,3F 12 No 1.3 3.82 1.69 2.05 0.08 1.37 $0.00 WKAl2-100C/FR 12 Yes 100 12.09 6.65 8.31 0.33 72.75 $0.00 WKAl2-100J/FR 12 Yes 100 12.09 6.65 8.31 0.33 72.75 $0.00 WKAl2-125C/FR 12 Yes 140 13.43 6.81 11.06 0.44 104.72 $0.00 WKAl2-12F2 12 No 12 5.94 3.90 3.74 0.15 9.26 $0.00 WKAl2-18C/FR 12 Yes 18 7.13 3.03 6.57 0.26 13.89 $0.00 WKAl2-18NB 12 No 18 7.13 3.03 6.57 0.26 13.89 $0.00 WK.Al2-2ST 12 No 2 5.91 0.79 3.54 0.14 1.65 $0.00 WKAl2-2.3F 12 No 2.3 6.97 1.38 2.40 0.09 2.03 $0.00 WKAl2-33C 12 WKAl2-33J 12 WK.A1244C/FR 12 WKAI2-5.1A 12 WKAl2.55C/FR 12 WKAl2-55PIFR 12 WKAI2-5F 12 WKAl2-7.5F 12 WKAl2-7.5F2 12 WKAl2-80C/FR 12 WKAl2-80J/FR 12 WKA44.5F2 4 WKA6-1.3F 6 WKA6-10F 6 WKA6-12F 6 WKA6-12F2 6 WKA6-14A 6 WKA6-14T1 6 7.72 16 6.10 0.24 7.72 16 6.10 0.24 Yes 45 7.80 No 4. 5.51 Yes 60 9.02 Yes 60 9.02 No 5 No 7. No 7. No 14 4.25 2.80 5.51 0.22 6.17 No 14 4.25 2.80 5.51 0.22 6.17 No 14 4.25 2.80 5.51 0.22 6.17 No 14 4.25 2.80 5.51 0.22 6.17 No 3.2 5.28 1.34 2.40 0.09 1.57 No 42 6.38 3.46 6.42 0.25 15.87 No 42 6.38 3.46 6.42 0.25 15.87 No 5 276 1.85 3.98 016 2.05 5.43 8.19 0.32 40.34 5,43 8.19 0.32 40.34 2.76 3.98 0.16 4.03 2.56 3.74 0.15 6.02 2.56 3.74 0.15 6.02 6.65 8.31 0.33 55.11 6.65 8.31 0.33 55.11 $0.00 $0.00 $0.00 $0.00 VVr/0-(.1l- 0 NO (.Z b.t4 1.114 i.(4 U.1b Z.O 11u.UU WKA6-8.2F 6 No 8.2 3.90 2.24 4.53 0.18 3.77 $0.00 Shipping and applicable sales lax is not included. Pricing is subject to change after 30 days. For more information please contact: Batteries Plus Roger Strand 945 W. Valley Parkway 760-839-0001 Fax 760-839-0055 As-mmc~e~#~Ilm Ascent Battery Supply, LLC 925 Walnut Ridge Drive Hartland, Wisconsin 53029 Material SafetY Data Sheet Sealed Lead Acid - AGM Type The information and recommendations below are believed to be accurate at the date of preparation. Ascent Battery makes no warranty of merchantability or any other warranty, express or implied, with respect to such information and we assume no liability resulting from its use. This MSDS sheet provides guidelines for safe use and handling of the product. It does not and cannot advise all possible situations. Your specific use of this product should be evaluated to determine if additional orecautions must be taken. Ascent Battery Supply, Emergency Company LLC Number INFOTRAC 800-535-5053 Ascent Battery Supply, LLC Overseas 925 Walnut Ridge Dr. Emergency Address Hartland, WI 53029 Number INFOTRAC 800-535-5053 Revision Date 09/05 jECTION I - IDENTITY Product Name Sealed Lead Acid Battery Common Synonyms SLA, VRLA, AGM, Sealed Recombinant DOT Description Wet Battery, non-spillable Chemical Name Sealed Lead Acid; Secondary Battery Battery SECTION 2 - HAZARDOUS INGREDIENTS Chemical Name CAS No. Percentage % Lead 7439-92-1 50 Lead Dioxide 1309-60-0 21 Lead Sulfate 7446-14-2 1 Sulfuric Acid 7664-93-9 22 Case Material N/A 6 SECTION 3— PHYSICAL AND CHEMICAL CHARACTERISTICS Boiling Melting Point > F Vaoor Pressure NA Vapor Density NA Specific Gravity Lead, approx. 13 Percent Volatile By Volume None Solubility in Water NA Reactivity In Water NA Appearance and Odor Rectangular polypropylene Evaporation Rate NA or polystyrene case with lead terminals Flash Point Polypropylene case Flammable Limits in Air % NA 675° F by Volume Extinguisher Media Hakn, dry chemical Auto-Ignition Temperature NA Special Fire Extinguish fire with agent suitable for surrounding combustible materials. Cool exterior of battery it. Fighting exposed to fire to prevent or stop release of lead chemicals and fumes. Procedures Unusual Fire and None Explosion Hazards [SECTION 4— PHYSICAL HAZARDS Stable or Unstable Stable Conditions to Avoid Electrical shorting the battery. Incompatibility Keep battery clear of strong oxidizers and solvents. (Materials to Avoid) Hazardous NA Decomposition Hazardous Will Not Occur Polymerization [SECTION 5— HEALTH HAZARDS Threshold Permissible exposure limits Lead TVL 0.15mg/rn3 PEL 0.05mgIm Limit Value Sulfuric Acid TVL 1 Mg/M3 PEL 1mg/rn3 Signs and Symptoms Exposure to sulfuric acid, lead, lead dioxide, or lead sulfate may occur if the sealed battery case of Exposure is damaged. Exposure to lead may include: Chronic over exposure: Tire easily, loss of appetite, irritability, metallic taste, insomnia; toxic to nervous system, kidneys and reproductive system. Acute overexposure: Constipation, vomiting, blue line on gums, weak wrists and ankles, weight loss, yellowish skin. Exposure to sulfuric acid: Chronic over exposures: inhalation-erosion of teeth, inflammation of nose, throat and bronchial tubes. Acute overexposure: Eyes - severe bums, cornea damage, blindness. Skin - severe irritation, burns, ulceration. Inhalation - respiratory irritation, inflammation of bronchial membranes. Ingestion- severe bums of the mouth, throat, esophagus and stomach, damage to kidney and intestinal tract. Medical Conditions Respiratory exposure to airborne sulfuric acid will increase damaged to lungs and other Generally Caused by pulmonary conditions. Harmful effects of lead are increased for a person with dietary deficiencies Exposure in calcium, iron and zinc. Routes of Entry Skin, Eyes, Swallowing Emergency and First Lead and Sulfuric Acid Aid Procedures for i. Inhalation Get fresh air. If symptoms persist seek medical attention 2. Eyes and Skin If a cell ruptures flush, with copious quantities of flowing lukewarm water for a minimum of 15 minutes. Get immediate medical attention for eyes. Wash skin with soap and water. Remove all contaminated clothing. 4. Ingestion Ingestion of battery chemicals can be harmful. Call The National Battery Ingestion Hotline (202-625-3333) 24 hours a day, for procedures treating ingestion of chemicals. Do not induce vomiting. Dilute by giving milk and water. Do not give anything by mouth to an unconscious SECTION 6- SPECIAL PROTECTION INFORMATION Respiratory If product is involved in fire, it may cause the release of dust and fumes and the use of a face mask Protection is recommended. Ventilation Charge batteries in a well Local NA Mechanical NA ventalated area. Exhaust (General) Gloves Use gloves when handling Safety Glasses Always wear safety glasses when working with SLA batteries, batteries and cells. I SECTION 7- SPECIAL PRECAUTIONS - SPILL AND LEAKAGE PROCEDURES I Storing Procedures Store in dry and ventilated area. Other Precautions Do not store in air tight container. Do not allow metal or other conductive materials to short circuit terminals Steps if chemicals Will not occur unless case is damaged or vents. Pick up damaged materials and place in container. are spilled Neutralize sulfuric acid with lime, soda ash or sodium bicarbonate. Waste Disposal Batteries must be recycled. jortation Considered to be 'Wet Batteries" but are non-spillable. All of our lead acid batteries are unregulated by DOT for transportation by truck, rail, ocean and air transportation because they meet the requirements of 49 CFR 173.159 (d). The only transportation requirements are: The battery must be securely packaged in such a way to prevent the possibility of short circuiting. The battery and the outer most packaging must be labeled NONSPILLABLE or"NONSPILLABLE BATTERY". 3 Asc " Material Safety Data Sheet Ascent Battery Supply, LLC 925 Walnut Ridge Drive Hartland, Wisconsin 53029 Sealed Lead Acid - AGM TvDe The information and recommendations below are believed to be accurate at the date of preparation. Ascent Battery makes no warranty of merchantability or any other warranty, express or implied, with respect to such information and we assume no liability resulting from its use. This MSDS sheet provides guidelines for safe use and handling of the product. It does not and cannot advise all possible situations. Your specific use of this product should be evaluated to determine if additional precautions must be taken. Emergency Company Ascent Battery Supply, LLC Number INFOTRAC (800) 535-5053 Ascent Battery Supply, LLC Overseas 925 Walnut Ridge Dr. Emergency Address Hartland, WI 53029 Number INFOTRAC (800) 535-5053 Revision Date 08/22/05 SECTION 1 - IDENTITY Product Name Sealed Lead Acid Battery Common Synonyms SLA, VRLA, AGM, Sealed Recombinent DOT Description Wet Battery, non-spillable Chemical Name Sealed Lead Acid; Secondary Battery SECTION 2— HAZARDOUS INGREDIENTS Chemical Name CAS No. Percentage % Lead 7439-92-1 50 Lead Dioxide 1309-60-0 21 Lead Sulfate 7446-14-2 1 Sulfuric Acid 7664-93-9 22 Case Material N/A 6 SECTION 3— PHYSICAL AND CHEMICAL CHARACTERISTICS Boiling Point NA Melting Point Polypropylene > 320° F Vapor Pressure NA Vapor Density NA Specific Gravity Lead, approx. 13 Percent Volatile By Volume None Solubility in Water NA Reactivity in Water NA Appearance and Odor Rectangular polypropylene Evaporation Rate NA or polystyrene case with lead terminals Flash Point Polypropylene case Flammable Limits in Air % NA 675° F by Volume Extinguisher Media Halon, dry chemical Auto-Ignition Temperature NA Special Fire Extinguish fire with agent suitable for surrounding combustible materials. Cool exterior of battery if Fighting exposed to fire to prevent or stop release of lead chemicals and fumes. Procedures Unusual Fire and None ExDlosion Hazards [SECTION 4— PHYSICAL HAZARDS Stable or Unstable Stable Conditions to Avoid Electrical shortinc the battery. Incompatibility Keep battery clear of strong oxidizers and solvents. to Avoid) Hazardous NA Decomposition Hazardous Will Not Occur Polymerization - CTION5— HEALTH HAZARDS Threshold Permissible exposure limits Lead TVL 0.15mg/rn3 PEL 0.05mg/rn3 Limit Value Sulfuric Acid TVL 1 Mg/M3 PEL 1 Mg/M3 Signs and Symptoms Exposure to sulfuric acid, lead, lead dioxide, or lead sulfate may occur if the sealed battery case of Exposure is damaged. Exposure to lead may include: Chronic over exposure: Tire easily, loss of appetite, irritability, metallic taste, insomnia; toxic to nervous system, kidneys and reproductive system. Acute overexposure: Constipation, vomiting, blue line on gums, weak wrists and ankles, weight loss, yellowish skin. Exposure to sulfuric acid: Chronic over exposures: inhalation-erosion of teeth, inflammation of nose, throat and bronchial tubes. Acute overexposure: Eyes - severe burns, cornea damage, blindness. Skin - severe irritation, burns, ulceration. Inhalation - respiratory irritation, inflammation of bronchial membranes. Ingestion- severe burns of the mouth, throat, esophagus and stomach, damage to kidney and intestinal tract. Medical Conditions Respiratory exposure to airborne sulfuric acid will increase damaged to lungs and other Generally Caused by pulmonary conditions. Harmful effects of lead are increased for a person with dietary deficiencies Exposure in calcium, iron and zinc. Routes of Entry Skin, Eyes, Swallowing Emergency and First Lead and Sulfuric Acid Aid Procedures for Inhalation Get fresh air. If symptoms persist seek medical attention Eyes and Skin If a cell ruptures flush, with copious quantities of flowing lukewarm water for a minimum of 15 minutes. Get immediate medical attention for eyes. Wash skin with soap and water. Remove all contaminated clothing. 4. Ingestion Ingestion of battery chemicals can be harmful. Call The National Battery Ingestion Hotline (202-625-3333) 24 hours a day, for procedures treating ingestion of chemicals. Do not induce vomiting. Dilute by giving milk and water. Do not give anything by mouth to an unconscious person. SECTION 6— SPECIAL PROTECTION INFORMATION Respiratory If product is involved in fire, it may cause the release of dust and fumes and the use of a face mask Protection is recommended. Ventilation Charge batteries in a well Local NA Mechanical NA ventalated area. Exhaust (General) Gloves Use gloves when handling Safety Glasses Always wear safety glasses when working with SLA batteries, batteries and cells. SECTION 7—SPECIAL PRECAUTIONS - SPILL AND LEAKAGE PROCEDURES Storing Procedures Store in dry and ventilated area. Other Precautions Do not store in air tight container. Do not allow metal or other conductive materials to short circuit terminals Steps if chemicals Will not occur unless case is damaged or vents. Pick up and place in materials in container. are spilled Neutralize sulfuric acid with lime, soda ash or sodium bicarbonate. Waste Disposal Batteries must be recycled. Transportation Cosidered to be 'Wet Batteries' but are non-spillable. All of our lead acid batteries are unregulated by DOT for transoprtation by truck, rail, ocean and air transportation because they meet the requirements of 49 CFR 173.159 (d). The only transportation requirements are: The battery must be securely packaged in such a way to prevent the possibility of short circuiting. The battery and the outer most packaging must be labeled "NONSPILLABLE" or "NONSPILLABLE BATTERY". -2-