City of Carlsbad
Fire Alarm Permit
Permit No: FA070036
Job Address: 7270 CALLE PLATA Status: ISSUED
Permit Type: FALARM Applied 3/12/2007
Parcel No: 2238101600 Approved: 3/13/2007
Lot #: 0
Reference No.: Issued: 3/13/2007
PC #: Inspector:
Project Title: HUNTERS POINT-COMMONS TWO FIRE ALARM INSPECTIONS @
$62/EA
Applicant: Owner:
CITY-WIDE ELECTRONIC SYSTEMS
P 0 BOX 2069
EL CAJON CA
619-444-0219
Fees ($) TAdd'I Fees ($) J Total ($) Balance
124 0 124 0
about:blarik 1/1
FROM (W ED) AUG 1 2007 8:45/ST, 8 : 4 4 H 2 16~_l dC~s~ly I
- - O
Record of Completion
Name of Protected Property; rt4e.rS -c!)n+e.
Address: COh'llnLnit't 'J/c 7270 C&le p/cdc
Rap. Of Protected Prop.(name/phono): . /LC K. 5vy Ke_I ' 700 1337
Authority Having Jurisdiction: LAAV 15 U.A(4 £F'
Address (Phone Number: / 7O 602 160
1. Type(s) of System or Service
nun NFPA 72, Chapter 3 - Local
I If alarm is transmitted to location(s) off premises, list where received:
NFPA 72, Chapter 3— Emergency Voice I Alarm Service
Quantity of Voice / Alarm channels: Single:
Quantity of speakers Installed:
Quantity of telephones or telephone jacks Included In system:
NFPA 72, Chapter 4 -Auxiliary
Indicate type of connection;
Local energy; Shunt: -- ...........
Location and telephone number for receipt of signals:
NFPA 72, Chapter 4— Remote Station
Alarm:
Supervisory;
NFPA 72, Chapter 4-. Proprietary
If alarms are retransmitted to public fire service communications center or others. Indicate location and telephone number of the
Organization receiving alarm:
Indicate how alarm is retransmitted:
Multiple:
Quantity of speaker zones;
Pemliel tAlAphnnol
NFPA 72, Chapter 4— Central Station
The Prime Contractor: 'i I. •
At b5
Central Station Location:
c0 3u$te .'L_PQWC4h1 C / 5& S726
Means of transmission of signals from the protected premises to the central station; 0 - McCultoh 0 - Multiplex 0 - One-Way Radio
- Digital Alarm Communicator U . Two-Way Radio U - Others
Means of transmission of alarms to the public senice communications center; je
-b.
. B' L- . --
System Location; "j te..i
Representative N e/ Phone Organization Name I Phone
Installer CituJS) V.c_i_I 144 Odi Miçt
Supplier rrs-r ell N - - Q 24
Service Organization _jti..LC.
Location of Record (As-Built) Drawings:0 , (., C)4
Location of Owners Manuals: j54 4 -
Location of Test Reports:Ct cs 'V)Cr
A contract, dated ol ,for test and inspection in accordance with NFPA standard(s) No(s).
dated 1-' (71 - ir, in affect.
FROM (ED)AUG 1 2037 8:45/ST. 8:44/NO. 6312264210 P 2
Record 01 System installation
(Fill out alter installation Is complete and wiring checked for opens, shorts, ground Faults, and improper branching, but prior to
conducting operational acceptance tests.)
This syst hbe(5Jstalled In accordance with the NFPA standards as shown below, was inspected by
on inOIud the devices shown below, and has been in service since 7-30,01
-- NFPA 72, Chapters 1 2 I' 4 5 LB 8 D 7 (check all that apply)
NFPA 70, National Elechfcal Code, Article 760
Manufacturer's Instructions
Other (specify):
Signed; Date: 7 3.67
Organization: .Cthc cnic5
Record of System Operation
All operational features and functions of this system were tested by RZtbe.1 (9YC#.4on
found to be operating properly in accordans the rtilremJntpfr -
and
NFPA72, Chapters 1 22 30'-4.0"523 b '-1D (check all that apply)
NFPA TO, National Electrical Code, Article 760
-- Manufacturer's instructions
Other (specify):
Date:Signed: AC M1tjC4"
I
CL
Organization: (1r { LLi(,1-C c4rnOr1 c3
Alarm-Initiating Devices and Circuits (uso blanks to indicate quantity of devices)
MANUAL C Manual Stations "—''Noncoded, Activating Tranamittom Coded
Combination Manual Fire Alarm and Guards Tour Coded Stations
AUTOMATIC
Coverage; Complete:
. - .L_ )ffoke Detectors jfon
Duct Detectors / Ion
(C) Heat Detectors /' FT ______
(d) Sprinkler Weterfiow, Swj)Iies:
Other (list),
Supervisory Signal-inItiating Devices and Circuits (use blanks to indicate quantity of devices)
GUARD'S TOUR
/ Coded Stations
/ Noncoded Stations, Activating ''"rransmitters
_/ Compulsory Guard Tour System Comprised of Transmitter Stations and
lntbnnediete Stations
NOTE: Combination devices recorded under 4(b) and S(a).
KI. SPRINER SYSTEM 2-. / Coded Valve Supervisory Signaling Attachments / Valve Supervisory Switches, Activating Transmitters
. f_ Building Temperature Points
_/__ Site Water Temperature Points I Site Water Supply Level Points
Electric Fire Pump:
/ Fire Pump Power
(h) / Selector in Auto Position
(I) f Engine or Control Panel Trouble
/ Fire Pump Running
Engine-0hren Generator;
, Selector In Auto POSILIOn
(I) / Control Panel Trouble
/ Transfer Switches
" . Engine Running
Partial:
Ph
oto
Photo
- RR
-
FTJRR . RC
ransmitters Noncoded, Activating .... Coded
(fl Fire Fire Pump Running
(g) Phase Reversal / /
Engine-Cven Fire Pump:
F ROM (ED)AUG 1 2007 8:45/ST, 8:44/NO. 6312264210 P. 3
Other Supervisory Function(s) (specify).
8. Alarm Notification Appliances and Circuits
Quantity of indicating appliance circuits connected to the system:
Types and quantities of alarm indicating appliances installed;
) Bells — Inch
Speakers
Horns
Chimes
—'-- Other:
- Visual Signals Tyg -
With audible i.— Wfo audible
. Local Annunciator
7. Signaling Line Circuits
Quantity and Style , ,NFPA72, Table 3-6) of signaling line circuits connected to system:
Quantity: Style: -
8. System Power Supplies
Primary (Main): Nominal Voltage: ii C) V Current Rating:
Overcurrent Protection: Type Current Rating:
Location; -
Sejq,y (Standby);
Storage Battery: Amp-Flour Rating 2 # ().aa(304q Calculated capacity to drive system, in ii 24
Engine-driven generator dedicated to fire alarm system:
Location of fuel storage:
Emerncy or Standby System used as backup to Primary Power Supply, instead of using a Secondary Power Supply:
Emergency System described in NFPA 70. Article 700
Legally Required Standby System desoilbed In NFPA 70, Adele 701
Optional Standby System described in NFPA 70, Article 702, which also meets the performance requirements of Article
700 or 701.
9. System Software
. C Operating System Software Revision Level(s):
Application Software Revision Level(s): -........—
Revision Completed by;
(name) . (firm)
10.~~,X4 -_7
(signed) for Central Station or Alarm Service Company (title) . (date)
Frequency of routine tests and inspections, If other than In accordance with the referenced NFPA standard(s):
System deviations from the referenced NFPA standard(s) are:
YL
(signed) for Central StatioAlarilervice Company -(ttie) (date)
Upon completion of the s (tisfactory test(s) witflAteid (if rnqulrad by the authority having jurisdiction):
6-ign'e'd)--r—epresentative of (no
7
aujority having jurisdiction (title)