1969 PALOMAR OAKS WAY; ; FA120021
9/16/2020 FA120021 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA120021 1969 PALOMAR Job Address: Status: APPROVED OAKS WY Permit Type: FALARM Applied 4/26/2012 Parcel No: 2130922000 Approved: 5/1/2012 Lot #: 0 Reference No.: Issued: 5/1/2012 PC #: Inspector: Project Title: AIR PRODUCTS TI Fire Alarm system expansion into new area (Glass Room) Applicant: Owner: JJJ ENTERPRISES AIR PRODUCTS&CHEMICALS INC C/O J C SCHUMACHER CO 533 S VINEWOOD ST 1969 PALOMAR OAKS WAY ESCONDIDO CA CARLSBAD CA 760-747-3050 Fees ($) Add'l Fees ($) Total ($) Balance ($) 257 0 257 0 1/1 FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS AIR PRODUCTS T.I. I 1969 PALOMAR OAKS WAY CARLSBAD, CA 92088 FIRE.ALARM SYSTEM A FIkI2.002( dn-6927:a FCPS.24S6(CIE) & FCfS. N OTI F E R® 6-& 8-Amp 24-Volt by Honeywell Remote Power Supplies General -. --.--- i The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger. The FCPS-24S6/- 24S8 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance (bell) circuit (NAC) expansion (to support ADA requirements and NAC syn- chronization) or auxiliary power to support 24 volt system accessories. The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable, all resettable or two non- resettable and two resettable. The FCPS-24S6/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C & FCPS-24S8C are ULC-listed. NOTE: Unless otherwise specified, the terms FGPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E Features UL-Listed NAC synchronization using System Sensor, Wheelock, or Gentex "Commander2" appliances. Operates as a "sync-follower" or as a "sync-generator" (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumped perma- nently "ON" (stand-alone mode). Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module) NACs. 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load out- put, with 3 amps maximum/circuit, in NAC expander mode (UL 864). 4-amp (FCPS-2456) or 6-amp (FCPS-24S8) continuous output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NACs. Selectable earth fault detection. AC trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9 - 32 VDC. Self-contained in compact, locking cabinet - 15"H x 14.5W x 2.75'D (cm: 38.1 H x 36.83W x 6.985D). Inc udes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed,--lamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FCPS-2456C/-24S8C: 120 VAC, 60 Hz, 3.2A maximum. FCPS-24S6E/-24S8E: 240 VAC, 50 Hz, 1.6A maximum. Wie S ze: minimum #14 AWG (2 0mm) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 V1-1C. Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 - 16 V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. Tolal continuous current for all ou:puts (stand-alone mode): - FCP-24S6: 4.0 Aiiaximum. - FCPS-24S8: 6.0 A maximum. To-.al short-term current for all outputs (NAC expander mode): - FCPS-2456: 6.0 A maximum. - FCPS-24S8: 8.0 A maximum. Secondary Power (Battery) Charg ng Circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. dn-€927:a • 04/30/09 - Page 1 at 2 Maximum current charge: 1.5 A. Maximum battery capacity: 18 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A (FCPS-24S8). Both resettable and non-resettable power options are available. Resettable outputs are created by con- necting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. - "NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet (3,810 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-24S6/-2458 can track (i.e. "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24S6/-24S8 is configured (via DIP switch set- tings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24S6/-24S8 are configured (via DIP switch settings) as a "sync generator:' the FCPS's sync input termi- nals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator" mode, the sync type (System Sensor, Whee- lock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24S6 and FCPS-2458 comply with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635, S674 ULC Listed: S635(FCPS:24S6C & FCPS24S8C) CSFM Approved: 7315-0028:225 MEA: 299-02-E FM Approved Ordering Information FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S6C: Same as above, ULC-listed. FCPS-24S6R: Same as FCPS-24S6 with red enclosure. FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8: 8.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8C Same as above, ULC-listed. FCPS-24S8R: Same as FCPS-24S8 with red enclosure. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power. BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). PS-1270: Battery, 12-volt, 7.0 AH (two required, see PS Series data sheet DN-1109) System Sensor® and NOTIFIER® are registered trademarks of Honeywell International Inc. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so 9001 We try to keep our product information up-to-date and accurate. 93=1=1 We cannot cover all specific applications or anticipate all requirements. MCINFERINS & MNUFADIBIN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 - dn-6927:a • 04/30/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0028:0225 Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com DESIGN: Models FCPS-24S6 and FCPS-24S8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:0206 1-24-03KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 - Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division DN-6935:1) • H-202 C, I n_:: I, COTIFER® by Honeywell General FSP-851 (A) Series Intelligent Plug-In Photoelectric Smoke Detectors with FlashScan® Notifier FSP-851 (A) Series intelligent plug-in smoke detectors with integral communication provide features that surpass con- ventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The FSP-851 (A) photoelectric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the FSP- 851T(A). The FSP-851 R(A) is a remote test capable detector for use with DNR(A)/DNRW duct detector housings. FSP-851 (A) series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication proto- col developed by Notifier that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory. Dual LED design provides 360° viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan systems only). Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. Specifications Sensitivity: 0.5% to 2.35% per foot obscuration Size: 2.1" (5.3 cm) high; base determines diameter - B21OLP(A): 6.1' (15.5 cm) diameter. - B501 (A): 4.1" (10.4 cm) diameter. - 13200S(A): 6.875" (17.46 cm) diameter. / FSP-851(A) in B2IOLP(A) Base - 13200SR(A): 6.875" (17.46 cm) diameter. - B224RB(A): 6.2' (15.748 cm) diameter. - B224B1(A): 6.2" (15.748 cm) diameter. Shipping Weight: 5.20z. (147g). Operating Temperature range: FSP-851(A), 0°C to 49°C (32°F to 12D°F). FSP-851T(A), 0°C to 38°C (32°F to 1000F). Low temperature signal for FSP-851T(A) at 45°F +1- 10°F (7.22°C +1- 5.54°C). FSP-851 R(A) installed in a DNR(A)/DNRW, -20°C to 70°C (-4°F to 158°F). ULIULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/ mm.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (57°C). DETECTOR SPACING AND APPLICATIONS Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.):-300JA @ 24VDC (one commu- nication every five seconds with LED enabled). LED Current (ma)'A @ 24 VDC ('ON"). Installation FSP-851(A) plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors without using a ladder. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps' or branches are permitted for Style 4 (Class "B') wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation DN-6935:D • 12/08/2011 - Page 1 of 2 sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S1 115. ULC Listed: S1115 (FSP-851A, FSP-851RA, FSP-851TA). MEA Listed: 225-02-E. FM Approved. CSFM: 7272-0028:0206. Maryland State Fire Marshal: Permit #2122. BSMI: C1313066760036. CCCF: Certif. #2004081801000017 (FSP-851T) Certif. # 2004081801000016 (FSP-851). U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-3200, excluding B21OLP(A)). Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B21OLP(A)). Product Line Information NOTE: "A" suffix indicates ULC Listed model. FSP-851: Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. FSP-851A: Same as FSP-851 but with ULC listing. FSP-8511: Same as FSP-851 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-851TA: Same as FSP-851T but with ULC listing. FSP-851 R: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNRAIDNRW. FSP-851 RA: Same as FSP-851 R but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details on intelligent bases, see DN-60054. B21OLP(A): Standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501 (A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tempo- ral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224R8(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A © 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A © 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases. ACCESSORIES FllO: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low- profile. Fl 1OBP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B21OLP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-200B: Black detector covers for use with FSP-851 (A) only; box of 10. WCK-200B: White detector covers for use with FSP-851 (A) only; box of 10. -Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I 0 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6935:D • 12/08/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:0206 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FSP-751, HPX-751, FSP-7511, FSH-751, FAPT-751, FAPT-851, FSP-851, FSP-851 R* and FSP-851T photoelectric type smoke detectors. Models FSP-751T and FSP-851T employ a 135°F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. Models FSP-751, FSP-751 T, FAPT-751, FAPT-851, FSP-851, FSP-851 R*, FSP-851 T are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air velocities between 0-300 fpm. Model FSH-751 is suitable for open areas with air velocity between 0-4000 fpm. NOTE: Combined with 7272-0028:208 The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-07-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0173 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models BX501, B61OLP, B612LP, B614LP, B6I6LP and B71OLP detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. *Corrected 10-20-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires JUne 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division DN-6936:B • H-211 FST.851 (A) Series Intelligent Thermal (Heat) Detectors with FlashScan® General Notifier FST-851 (A) Series intelligent plug-in thermal detectors with integral communication has features that surpass conven- tional detectors. Point ID capability allows each detector's address to be set with rotary, decimal address switches, pro- viding exact detector locations. FST-851 (A) Series thermal detectors use an innovative thermistor sensing circuit to pro- duce 135°F/57°C fixed-temperature (FST-851/A) and rate-of- rise thermal detection (FST-851 R/A) in a low-profile package. FST-851H(A) provides fixed high-temperature detection at 190°F/88°C. These thermal detectors provide effective, intelli- gent property protection in a variety of applications. FST- 851(A) Series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by Notifier Engineering that greatly enhances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Rate-of-rise model (FST-851R/A), 15°F (8.3°C) per minute. Factory preset fixed temperature at 135°F (57°C); high-tem- perature model fixed at 190°F (880C). Addressable by device. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Two-wire SLC connection. Visible LEDs blink" every time the unit is addressed. 360°-field viewing angle of the visual alarm indicators (two bi-color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Integral communications and built-in device-type identifica- tion. Remote test feature from the panel. Built-in functional test switch activated by external magnet. Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). Low standby current. Backward-compatible. Built-in tamper-resistant feature. Designed for direct-surface or electrical-box mounting. Sealed against back pressure. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelec- tric, ionization and thermal sensors. SEMS screws for wiring of the separate base. Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. N OT IFP ER® by Honeywell FST-851(A) in B2IOLP(A) Base 94-5V plastic flammability rating. Remote LED output connection to optional RA100Z(A) remote LED annunciator. Optional sounder, relay, and isolator bases. Optional flanced surface mounting kit. Specifications Size: 2.1" (5.3 cm) high; base determines diameter. - B21OLP(A): 6.1 (15.5 cm) diameter. - B501 (A): 4.1° (10.4 cm) diameter. - B200S(A): 6.875° (17.46 cm) diameter. - B200SR(A): 6.875° (17.46 cm) diameter. - B224RB(A): 6.2" (15.748 cm) diameter. - B224B1(A): 6.2° (15.748 cm) diameter. Shipping weight: 4.8 oz. (137 g). Operating temperature range: FST-851 (A) Series, FST- 851 R(A): —20°C to 38°C (-4°F to 100°F); FST-851 H(A): —20°C to 66°C (-4°F to 150°F). Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% - 93% noncondensing. Thermal ratings: fixed-temperature setpoint 135°F (57C), rate-of-rise detection 15°F (8.3°C) per minute, high tempera- ture heat 190°F (880C). ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak. Standby current (max. avgj:.300 pA @ 24 VDC (one com- munication every 5 seconds with LED enabled). r LED current (max.):6 mA @ 24 VDC ("ON"). Applications Use thermal detectors for protection of property. For further information, go to systemsensor.com for manual 156-407-00, Applications Manual for System Smoke Detectors, which pro- vides detailed information on detector spacing, placement, zoning, wiring, and special applications. DN-6936:B • 12/07/2011 - Page 1 of 2 Installation The FST Series plug-in intelligent thermal detectors use a sep- arate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. A spe- cial tool allows maintenance personnel to plug in and remove detectors without using a ladder Mount base (all base types) on an electrical backbox which is at least 1.5 (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document.ln some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S747. ULC Listed: S6978. MEA Listed: 383-02-E. FM Approved. CSFM: 7270-0028:0196. BSMI: C1313066760025. CCCF: Certif. #2004081801000018. U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B21OLP(A)). Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B21OLP(A)). Product Line Information NOTE: "A" suffix indicates ULC Listed model. FST-851: Intelligent thermal detector. Must be mounted to one of the bases listed below. FST-851A: Same as FST-851 but with ULC Listing. FST-851R: Intelligent thermal detector with rate-of-rise fea- ture. FST-851RA: Same as FST-851R but with ULC Listing. FST-851 H: Intelligent high-temperature thermal detector. FST-851HA: Same as FST-851H but with ULC Listing. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B21OLP(A): Standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200S(A): Addressable Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Intelligent relay base. Screw terminals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC induc- tive. B224B1(A): Intelligent isolator base. Isolates SLC from loop shorts. Maximum: 25 devices between isolator bases; see Note 2 under Installation. ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. Supported by B21OLP(A) and B501 (A) bases only. SMB600: Surface mounting kit, flanged. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. Includes T55-127-01 0. T55-127-010: Detector removal tool without pole. XP-4: Extension pole for XR28. Comes in three 5-foot (1.524 m) sections. Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. 02011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. i I I ITICINEEKINS A 110FACTIIIIIING All specifications are subject to change without notice. I I QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2— DN-6936:13 • 12/07/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0028:0196 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FST-751, *..851 *851 R, *851 H (fixed temperature) and FST-751 R (fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: *Models FST-751, -751 R, -851, and -851 R = 135°F fixed temperature *Model FST-851 H = 190°F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Models B501 or B710LP base (CSFM Listing No. 7300-0028:173) and separately listed compatable fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 2-04-2003KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item -listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division 10 1111111111t I Strobe, Horn Strobe, and Horn Notification Appliances Description: The Wheelocka ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelocka ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. - Save up to 48% in current draw* - Up to 9 models now in 1 appliance Save up to 14% cost of installation * Sleek Modern Aesthetics Finger Slide Switches Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95, 99 dB ' g 8 Candela Settings Wall - 15/1575/30/75/95/110/135/185 Ceiling - 15/30160/75/95/115/150/177 () Universal Mounting Base Ceiling and Wall Mounts to 8ackbox Types Environmentally Friendly Low Curren: Draw Compatibility and Requirements - Synchronize using the Nheelock Sync Modules or panels with built-in Wheelock' Patented Sync Protocol Compatible with UL Regulated Voltage using filtered VDC or unuttered VRMS input voltage - Strobes produce I flash per second over the Regulated Voltage ange Compared to competitive models Patented Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. - A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: Strobes are designed to flash at 1 flash per second minmum over their Regulated Voltage Rar -All candela ratings represent minimum effective strobe intensity based on UL Standard 1971 Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with e .1 ( ' I f 32 F to 12OF (OC to 49CC) and maximum humidity of 93°6 (± 20 ) UL 464 (86% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Low &Current ii Draw 'Strobe Ratings per UL Standard 1971 = Fewer Power Supplies UL Max Current* 24 VDC /24FWR 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 0.110 0.140 SIC 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 & Anechoic at 24 VDC UL Max Current* at Anechoic 99 dBA 24VDC 12VDC Regulated Voltage Model 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 0.125 •• • •E •• •• 24VDC 12VDC Regulated Voltage Model 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0 27ft 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 U.I8V 0.230 0.272 0.122 .. . .E Current* == .•.. 24VDC 12VDC Regulated Voltage Model 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0,084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 u Ii I 0 )0o 0.267 0.120 HornRatings per UL Anechoic - Model Regulated Voltage Range VDC 99dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 1 0.017 HNC 8.0-17.5 0.047 0.026 0.017 * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For su tibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see install itiii instructions. Specification & Ordering Information - Sync w/ Model Strobe DSM or Candela 12/24 Mounting Wheelock Power Options Supplies 4VDC- HSR 15/1575/30/75/95/110/135/185 X XUMB** HSW 15/1575/30/75/95/110/135/185 X HSRC 15/30/60/75/95/115/150/177 X XUMB** HSWC Strobes 15/30/60/75/95/1151150/177 X X UMB** STIR 15/1575/30/75/95/110/135/185 X X UMB** STW 15/1575/30/75/95/110/135/185 X X UMB** STRC 15/30/60/75/95/115/150/177 X X UMB** STWC 15/30/60/75195/115/150/177 X X UMB** HNR X X UMB** HNW X X UMB** HNRC X X UMB** HNWC X X UMB** NOTE: Due to continuu3 development of our products, specifications and offerings are subject to change witnout notice in accordance with Cooper Wheeloci. Irc., dba Cooper Notification standard terms and conditions. Wheelock* iC SAFEPATH WAV_E~ST i Notification Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder" Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produáe a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder- Spec Sheet 6/11 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc., 273 Branchport Ave, Long Branch, NJ 07740 Contact: Raylon Smith (732) 962-7832 Fax (732) 962-7856 Email: raylon.smith@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or (white). Additionally, a 'C' may be added for ceiling models and/or a -NR' may be added for non-resettable models. For non -NR models and optional '5' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational Z' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc., 273 Branchport Ave, Long Branch, NJ 07740 Contact: Raylon Smith (732) 962-7832 Fax (732) 962-7856 Email: raylon.smith@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a'-NR' may be added for non-resettable models. For non -NR models and optional '5' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational cfr requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division DN-6724:B3 (5 NOTIFIER® Control and Relay Modules by Honeywell ______________________ • General FCM-1 (A) & FRM.1 (A) Series FCM-1(A) Control Module: The FCM-1 (A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1 (A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1 (A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1 (A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM-1(A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 - 99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1 (A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1 (A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScan® releasing applications. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01-159). FCM-1 (A) The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1(A) provides two Form-C dry contacts that switch together. Operation Each FCM-1 (A) or FRM-1 (A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1 (A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1 (A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) DN-6724:B3 • 2/17/2011 - Page 1 of 2 Maximum NAC Line Loss: 4 VDC. External supply voltage (between Terminals T10 and Til): Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RIMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4° (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll; 255 pA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (114.3 mm) high x 4" (101.6 mm) wide x 1.25° (31.75 mm) deep. Mounts to a 4° (101.6 mm) square x 2.125° (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: 53705 (A version only) FM Approved CSFM: 7300-0028:0219 MEA: 14-00-E FDNY: COA #6067, #6065 Contact Ratings for FRM-1 (A) Current Maximum Load Application Rating Voltage Description 3A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded A .5 30 VDC Inductive Coded (LIR=5ms) 1A 3OVDC Inductive Coded (UR2ms) .3A 125 VAC Inductive Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: "A" suffix indicates ULC Listed model. FCM-1(A): Intelligent Addressable Control Module. FRM-1 (A): Intelligent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1 (A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document 156-1169. FRM-1(A) Installation document 156-3502. Notifier SLC Wiring Manual, document 51253. Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO ooi We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. g MMIIIIAM111ING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2- DN-6724:133 • 2/17/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0219 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1,.FSM-101, FDM-1, FTM-1 monitor modules and FCM-1, FRM-1 control modules*. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units.*Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 08-18-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division STANDARD GRADE. FIRE RATED one source, many solutions.® FireLite BIM 3D MODEL AVAILABLE 0 13 FIRE-RATED 3 HOSE STREAM TESTED POSITIVE PRESSURE TESTED FIRE-RATED GLASS CERAMIC FireLite® is a 3/16 (5 mm) thick fire-rated glazing material. It is listed for use in non-impact safety-rated locations such as transoms and borrowed lites with fire rating requirements ranging from 20 to 90 minutes. Trusted for over 20 years, the FireLite family of products now feature ultraHDTM Technology for superior color and surface quality. FEATURES Now with uItraHDTM Technology for improved surface quality, clarity and color FireLite Standard Grade is comparable to alternative fire-rated ceramics that are marketed as having a "Premium" finish Fire-rated for up to 90 minutes with required hose stream test Glass ceramic Clear and wireless Fits in Designer Series Fireframes® from TGP, or standard fire-rated frames Large sizes available May be lightly sandblasted or etched on one side without affecting fire rating Passes positive pressure test standards UL bC, UBC 7-2 and UBC 7-4 May be insulated (see FireLite IGU fact sheet) Note: This product is not a barrier to radiant heat, as it does not meet test standards ASTM E-119 or UL 263. If your jurisdiction requires a "barrier to heat" product, please contact Technical Glass Products regarding Pilkington Pyrostop®. LISTINGS Listed and labeled by Underwriters Laboratories, Inc." and Underwriters Laboratories of Canada. File number for labeled fire-rated assemblies is R13377. All above tests performed in accordance with UL 9, UL bC, ASTM [2010, CSFM 43.7, NFPA 80, NFPA 257, UBC 43.2, UBC 43.4, UBC 7-2, UBC 7-4, CAN S-104. Approved for use in New York City: MEA 290-90-M-6. Approved for use in Los Angeles: LARR 25798. MAX. EXPOSED AREA MAX. WIDTH OF EXPOSED MAX. HEIGHT OF EXPOSED RATING ASSEMBLY (j2 /ff2) GLAZING (in) GLAZING (in) 20 to 60 mm. OTHER THAN DOORS 3,325/23.09 95 95 90 mm. OTHER THAN DOORS 2,621 / 18.24 56-1/2 56-1/2 Check with frame manufacturer for maximum tested glass sizes and required stop height. Note Individual lite sizes cannot exceed "Max. Exposed Area shown above. SURFACE FINISH Premium Standard Obscure MAX. SHEET SIZE 48" x 96" 48" x 96" 36' x 96" Note: FireLite is not an impact safety-rated product and should not be specified as such. However, TGP does offer FireLite Plus® and FireLite® NT which carry both fire and impact safety ratings. Please ask for more details. MP TECHNICAL GLASS PRODUCTS fireglass.com 800.1+26.0279 I one source, marry solulions FAI2-Oo2 SPECIFICATIONS All glass designated on the drawings as fire-rated shall be 3/16' (5 mm) thick Firel-itell supplied by Technical Glass Products. The surface condition shall be either: Premium Grade; Standard Grade; or Obscure (patterned surface). Complete 3-part CSI format specifications are available online at fireglass.com, or by calling 800.426.0219. GENERAL CHARACTERISTICS THICKNESS: 3/16" (5 mm) overall Detail based on use of WEIGHT: 2.4 lb / ft2 Fireframes Designer Series APPROX. VISIBLE TRANSMISSION: 88% narrow profile framing APPROX. VISIBLE REFLECTION: 9% Glazing Thickness 3/16 —i° HARDNESS (VICKER'S SCALE): 100 Framewidth: 2 FIRE RATING: 20 minutes to 90 minutes Frame height: 2-3/4' IMPACT SAFETY RATING: None C. Stop height: 3/4 SIC RATING: 35 dB Pocket width: 1/2"-1-1/4" Edge clearance: 1/4 LABELING I. Bite: 1/2 Each piece of FireLite shall be permanently labeled with the FireLite logo, UL logO and fire rating. INSTALLATION FireLite shall be glazed into the appropriate fire-rated framing with an approved glazing compound (pure silicone, closed cell PVC tape or DAP 33 putty) as supplied by the installer. For 90 minute ratings that exceed 1,393 in', FireLite shall be glazed with fire-rated glazing tape as supplied by TGP. Inspect each piece of FireLite immediately before installation and eliminate any with observable edge damage or face imperfections. As with any glass produced by the "roll out" method, individual pieces of FireLite may contain minimal variations in thickness. Occasionally, process marks and small occlusions or seeds (bubbles, knots or crystals) may be apparent. However, since they do not generally impair the transparency or affect the technical performance of the glass, they do not represent cause for rejection. STORAGE & HANDLING FireLite must be handled with care during transportation, storage, inspection and installation. Store in a dry place. FAMILY OF PRODUCTS TGP offers a complete family of products for all your fire-rated glazing needs, ranging from 20 minute to 3 hour applications. Fireglass620 Fire-rated, impact safety-rated toughened glass FireLite® Fire-rated glass ceramic FireLite® NT Fire-rated, impact safety-rated glass ceramic with surface-applied film FireLite Plus® Fire-rated, laminated, impact safety-rated glass ceramic Firelite® IGU Fire-rated or fire/impact safety-rated insulated glass units Pilkington Pyrodur® Fire-rated, impact safety-rated glass Pilkington Pyrostop® Fire-rated, impact safety-rated transparent wall panels WireLite® Fire-rated, wired glass WireLite® NT Fire-rated, impact safety-rated wired glass with surface applied film Fireframes® Fire-rated framing & doors for use with all TGP glass products MP TECHNICAL GLASS PRODUCTS" fireglass.com 800.426.0279 one source. many solutions SIlL Casa °a:nl:. I :aLlle 5a: I eLla PG,s are eg:st,nd Ira,, .: ks it N Clacy C,, Cr. Lx'. s:':.I 'yrsalsp a' J Plkinto:, a,rl. ,re'rr,r. :rocac:"n -f P, :;nla5 ala, :,Irah , a rade",ar. a' 'ariGeal r,las, a,cth.c's. IPalilcaf GlOSS P pj .ts vv re,;,- :e'ra':cs a's Use So ref Mary SI It: la:le Ire rrg:slrra:i t,lnee;a'eo oIler. ri:ral Class N,lss" If.s folrr:0te5 ,, rUss or genal refpaot:ce oiy -, shIre:, I ar: retails plsare eat Teslrr:,cal Glass 5:10115W